Loading...
HomeMy WebLinkAboutPermit M93-0170 - CITY OF TUKWILA - MAINTENANCE SHOP:t Crtl. of it&Kjf TYAmmiekiimc. Ci o Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M93 -0170 Type: B -MECH Category: NRES Address: 14000 INTERURBAN AV S Location: Parcel #: 336590 -0925 Contractor License No: NORPAHAl23M5 TENANT CITY OF TUKWILA MAINTENANCE SHOP 14000 INTERURBAN AV S, TUKWILA, WA 98168 OWNER CITY OF TUKWILA 6200 SOUTHCENTER BLVD, TUKWILA`- ;WAa:98188 CONTRACTOR NOR PAC HEATING : & AIR -' CONDITION. '• Phone: 206 931-0610 3414 A STREET , SE, AUBURN, WA 98002 CONTACT AL NOAH ;. 3414 A.•SSTREET S`. E. , AUBURN, ; WA;. 98002 * * * * * * * * * * * * * ** **** * *yh * * * * * * * *k * * * * * * * * * * ** * ** * *'k * * ** ** * * * * * * * * * * * * ** Permit Descrip;tr1'on :° REMOVE /THE EXISTING TURBINE VENTILATORS, REPLACE UMC E d i t i o n ' : 19,9' 1 Print Name: WITH :PENN ;AIR EXHAUST F;AN8`.i * * * * * * * * * * * * ** * * ** ** * * *. * * * * ** ** * * *:tik *�r5� *ik *4** * * * * * ** *�k*k,k. * * * * : *'.W* * *k* Permit Center Auth'ari;zed" Signat'ur'e, Date I hereby,,'uertify that I have read and examinedthis permit and knoW;`the same to be; true and correct. All provisions of law and ordinances governing: this;;. work', will be complied with,- whether 'specified "herein;:'or not. The granting of ;,,this permit does not resume to- .give authority to, ,Violate or cancel th'e provisions of any o ther'$state: o,r local _laws regu l atihg construction the performance of work. " h am authorized to sign;:for and obtain this . bu'ild frig ,p;ermit. MECHANICAL PERMIT Valuation: 8;675.00 Total Permit Fee: t46.88 -Title: /LItS' (206) 431 -3670 Status: ISSUED Issued: 10/29/1993 Expires: 04/27/1994 ,hone: 206 931 -0610 This permit shall become n.u'1 "l an:d...void i,f,�the is not commenced within 180 days from the date of issi"aa n , f' ;'r ce °" ,rv.a '`✓ t f'�,��° w o "r k is suspended or abandoned for a period of 180 days'""frd'in "` We last inspection. AMOUNT OWING: �lQ .14:, CONTACTED L� 1� ^�� ,� w BY: (init.) ,.... DATE NOTIFIED 1 V t� ✓ — CO 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION BY: (init.) PROJECT NAME , CIS c')k - TUKUSI l O. Modnker arrs, 5h SUITE NO. SITE ADDRESS 1 4000 -.Y Moan 1rJ PLAN CHECK NUMBER Inc13 ono CITY OF TUKVI 4 '"' Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Tracking INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X " in box indicates which departments need to review the project. PARTMENT ..,'BUILDING - initial review O FIRE O PLANNING REFERENCE FILE NOS.: O OTHER ,,'BUILDING - final review IRIBUILDING OFFICIAL DATE:. PPROVE )eras- ff.3W2 ( OUTED) INIT: INIT: INIT: to 1 z'l 113 INIT: Fmk le/s) INIT: U..IREMEI 'MMEN' CONSULTANT: Date Sent - Date Approved - FIRE PROTECTION: U Sprinklers U Detectors UN /A FIRE DEPT. LETTER DATED: INSPECTOR: ZONING: BAR/LAND USE CONDITIONS? li Yes T No SCREENING REQUIRED? 0 Yes 0 No UMC EDITION (year): REVIEW COMPLETED 01/07/93 SITE ADDRESS SUITE # /4 0 o O /,v i fYQ uR ;3,f So 'Tu t1,wrt.14- w /4 VALUE OF CONSTRUCTION - $ '' 8, (..- 7 `J , v ' T' PROJECT NAME/TENANT C /rY or ru, <pca,. -4 (,('4,.c./rvi. - 4.4.,<.i 6 Hot ?) ASSESSOR ACCOUNT It 7 7 7 TYPE OF WORK: 0 New /Addition ® Modifications 0 Repair 0 Other: ZIP DESCRIBE WORK TO BE DONE: gi .t rfs /'tx, 7 ., t.tii� YGr.Lr /t_,�T'u.r_ _-Rc „,,.,tTN /d N, A,7,. ,_xl�4t -' t /=4.c' ... .7-,.v' Y;: !: }:�:';: ?i;}::i {i'S�;:t:•:: i� r' >iiii:::ii.'•:iY::::: i:•$:i ^:L':.,' ;t:;::; .r•O %i :: r : •i:•:t ;• ': Y • :Y< > : :•zY: s :;xY<: : :s >Y•::::<Y'YZ ::.::.,....::.: ..::.: TYt'? �..,..,: RAT .............................., ........ ..NUMOFUNtTS < >< > - 1 - 4 - -- 4..r ,.' /' 4/ lie .e / O CJ • 2� / c o C. ,= r !4G F( fl ADDRESS :34/ 4 ;-..., 5. . �vi3..,.e,r.J �-...,4 ..... ZIPS aQ ,� WA. ST. CONTRACTOR'S LICENSE # EXP. DATE BUILDING USE (office, warehouse, etc.) ,M , 4 /it jrr- nrA.t.. ... /4 NATURE OF BUSINESS: <144 / .. r 4 .sue c. r WILL THERE BE A CHANGE IN USE? ® No 0 Yes IF YES, EXPLAIN: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? IF YES, EXPLAM No 0 Yes . PROPERTY OWNER ctrr. c r.. in, ,.4. ,.._. , L .t- <i :ig.. O: T 711h : ' T' PHONE 4 . 3 (S., d o , ADDRESS G Z' c 60:, lf <1r4, ( e 7 7 7 Pt. r9. ZIP CONTRACTOR 4_,o� 1 - / 1' (_ N r /.,L c .ri PHONE e:2 3/0i..„(0 ADDRESS :34/ 4 ;-..., 5. . �vi3..,.e,r.J �-...,4 ..... ZIPS aQ ,� WA. ST. CONTRACTOR'S LICENSE # EXP. DATE >DE .0 ' PTI.O..: <> : <i :ig.. O: T 711h : ' T' <.DATE: » BAs M-' 6 . ' ' . '? UNITS1 . : ::yY .. . ..... PLAAN::. FEE< :> :` <'r C ..... ... ... . . . . . . ..... OTHER < .:::? >`` ....... : <: « ' ::::: >T TA CITY OF TUKWILA Department of Community Development - Building 6300 Bout/mentor Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK NUMBER c APPLICATION MUST BE FILLED OUT COMPLETELY MECHAIK CAL PERMIT APPLICATION Mechanical Fee Worksheet must also be filled out and attached to this application. FEES (for staff use only) BUILDING OWNER OR AUTHORIZED AGENT CONTACT PERSON E:R Ei , I ORIZ SIGNATURE .� l PRINT NAME 4L ti0 /1 ADDRESS 4/ -F 4 z r 5 /� 4 L ,/t ? c ,4 / -I ...................... . DATE PHONE ' . / c c� CITY21 u/;3,,z,,v 9Soa PHONE 41'3 / , APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER/AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more th nn once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 431 -3670. DATE APPLICATION ACCEPTED 10 Q S- DATE APPLICATION EXPIRES 06/07 /W } S' = i:s:'R 41jA9 - ijl'' k:? .' ti 3 ` -' Xi IOt DATE` Ifs . 'R Etit •t: •^ 3 .•.. : " 4•, '• — '64 �. • • • j; DEPARTMENT OF LABOR AND INDUSTRIES THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A w4i ' 1t1; ti f Y •,�''•� ' } '} °. rt' a�•� tit t t ', i t ).��i�t�: °y .. 7 .t4:310.(4 L l i, udG: 41 tit. ,S. . f' '• � t 3 3 e. P gy p. i +, t tAllit* i,...Jti,).� .;. t .z:� :,te ai t CS`Tii 1 � + "�.:•t4 t ip: i[:t ©11 4 e� . A:1 e, i ' t :e =' C °ot , :: It A,;,` $ ' ;xl:'..;� NORP ,C` .HtwA;TI NG'.8':',A/C '36lIs';A''ST S`'E °'STt`':i0'2 AUBURN WA '• :. 96004 F625.052.00013.02) ' L DETACH TO DISPLAY CERTIFICATE .J STATE OF WASHINGTON •r. ' 10: " 7 .o.dl@ 51SL�: � -' iyi_ rui._ PR0000430 J3 V ' 1 ot STATE OF WASHINGTON REGISTRATIONS AND LICENSES ORGANIZATION TYPE DOMESTIC PROFIT CORPORATION NORPAC F(EATING & AIR CONDITIONING, INC. 3414 "A" ST SE STE 102 AUBURN WA 98002 DOMESTIC PROFIT CORPORATION RENEWED. BY AUTHORITY OF SECRETARY OF STATE The above entty has been Issued the business registrations or licenses listed DEPARTMENT OF UCENSINO, BUSINESS UCENSE SERVICES, P.O. BOX 9034 OLYMPIA, W195507.9034 (206) 753.4401 INAIMm rnrtmRrioi w. UNIFIED BUSINESS ID #: 601 092 283 BUSINESS ID #: 001 EXPIRES : 06 -30 -1994 \ ••a• ! „. 41.6. . \'l -- nQ m 0 • • • Total Fees: oi;al `'H,1`l Pay Merit s: 48.88, 46..88' 0.. . 4! * *hhh`ir *+4k* * h+ k********: k** h***** kkh** is ****.kh * * ******k**** * ** *hh -C11'Y OF TUKWILA, WA TRANSMIT GENERA 9.38 h * * * * ** ** * * ?k * * * * * ** *'k ** * *h * %k* ** * *1r * *** * * * ** * * ** *k ***'* **A kk * * * *til GENERA 37..50 TRANSMIT :Number: 930015781 Amtiunti 4L 88 10/29/93 12 TOTAL .. 45.88 Perini No ..M93 Type::0 -MECH . MECHANICAL PERMIT,: CHECK ; ,.:..46.88 Fevre'''. No; 336590 -0 ?25 • CHANG3:.`, 0.00 8ite:;.Addr`ess::14000 :'INTERURBAN AV S 1 /01%93 5798A000 ``14:49 Payment 'Method: CHECK Notation: NORPAC HEATING In it; SLR : * *****r * * ***** * * * ** * ***k *****k *, **' k'** ** *k ** * *h **k* *.i * * *dkk** *h * ;' Account Code Description . Pal d 000/345:880, 'PLAN .CHgCK `:- NONRES 9.38 .000/.322.1'00 '.MECHANICAL NONRE8 ;. 37 40 Total (This Payment) n G.88 Address: 14000 INTERURBAN AV S CITY OF TUKWILA Permit No: M93 -0170 Tenant: CITY OF TUKWILA MAINTENANCE SHOP Status: ISSUED Type: B. -MECH Applied: 10/25/1993 Parcel #.: 336590 -0925 Issued: 10/29/1993 * ** * * *k*** * * * * *** * *** * * ** ** * * * * *** k * * * *vI * ** * ** **** *** *** k•k•k•k** *** ** *** ** k* Permit Conditions: _ 1. No changes will be made �tos� {t:h;e a;lansYnl = uess� approved by the Architect and the Tukw„ la "�B`ui lding Division . Electrical per mit sh'a1`�l "be obtained through the: Washington State Division of ;Labor acid I'naustr;i�es and� a ll ''ele'c >trical work will be,�r`i'ns`pecte.`d " b i pa�t ja (248 -,' - 663,0) . `~ �:k7 +- permits...,1nspecti'o,n i^'ecord ap s, and pro;ve�d�: plans shall be maintained vai.lab�l�e`t! at" the4. t'o,, star*t;Of any cons;t ..ibt ;on Thes.eidocum,ertts are to qte maintained availab untiyl,, f1' nal isrgr,an;te1' ,,, 4. All corrstructiorti" to�: be dome. °ih conformance with oved plans acid requirements o:F. the: Uniform Building Code (f991 Editio as amended byv`;the Wa hington Stat B �C and ; tlje Un l .Mechani:cal Code (199.1, Edition). . Va l idii'ty' of Penini t. The�- issua p 'nce of a permit or approval of Y4 , p' �utati, ' t t l 1 a�is'� s ecif iat i ans;, °and comm fartis °''sha.l�l not be con � stq d to be a= permit 'fo,r „o`r an appp'r0val ,of any violation o f fr o f tjh a :, o`.v.i s i'o s' o t h i s :cod O o rr r' t, `r y '�pi^ n e o`r ��of zany other. ord'inance •.af the jur t dA °ction� N m. , i :t� :p resuming t ;o g i ve, au i. ority�,ror .violate o ,thee �l . the pr } of this code.,,; shat b ..... � y% ... � � P ,�;;, 4 Y ,�' y v j a 1 i t .,, , o le ir; i !' ,! �t d� j," t. ; r :app 40 rte. ..1 t r Yr •n. - 1 3 75)ect: CA V . WC . S NO Type otlnspectk r"� N ►-- Address: v0 a h,.it6 Date Called: (9 - L Z Special Instructions: Ii•- • Pry 6T 61 eA wk 0.... o c+e3 . 6 64 a r.� -etc r F+ �'��' Date Wanted: G � Z3 �� am. p.m. Requester: V fL1'C)AN Phone No.: X 131 . ( 1 l PECTtON N0. INSPECTION RECORD C Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. 11153 0170 PERMIT NO. (20 431 -3670 0 Corrections required prior to approval. 0 $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be ' • id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 KM : • ' Mil . | { L - � ' hit the - b* .. _ ._ , ! ��,w !* i ! - -- �-` . � — / | � / . ` . � ' - ' • | � ! � | � T. ' -_ _ _. A111 11 Bi_ . ....., . . : ,,- : . _ , | ' i � - _ —� 11 111111 i • � ' H / i \ | | ' ' V | � ' | ' ! } ! __ � \ ! � � ' � | | � —� j ' ! � | — • | ! | ! � � | ' ! � • � ^^ —' _' . � � ' ^� III= II PA �' ' o ^ z� ' - -- -- � ^^ `� —"—��� �~' ^ ^�`� ^ | / ^ �^�`� ( 151*-.,--_ ` ' � | | �" / � • / ' — — — — — — v ' _- - - ElfilliEE _ _- , —_ _ — __ - — . ' ' __ . _' 1111 II II - - '- � —— | � -- ----- — — — l ' — —' — | — ' t,-. .. -- _� _—��� —_—_. __—' — ___ __ _ — — — --__ — — _ ' - I __ -_ __ --__ _' -- --_-'_-- -- ------ --- --- --- ----'----'� -- ---�-' l ---�----'-- � _ -� . �� �� -_ ___ _-'_ -_ __ 1 - ���� �N� | | ---- ---- i --- -- '- ---- - ' �� -- ! � / | ! ����� u�*�w� � =~ �� __ __._J ���'_ U �� � } �� - - � ^``' �~ / � � ■ � t_ - � F. - - `` � — � � -- � ` �� � � _ »y 3' u■ �, / l | ` � / / ' ' - ` | • i | � e ^� � �z ���� � ' ' ' -- - - - - | �' ' . � | � � . �= �, '-~' - - � '� __ - ` ' ' / } } ^ ' w/ | / � . ; n�� '___ ' __ ' ��� _�__ _' _ __ --� '^/ � � �f �` ' ' / ■ | ^l i / -- ' � ' ' ^ ' ' ' - 0�� �r ' �I0��� / | i - -- --| t / I -- m�x v ' �w�� __-- --_ � ' � '--�- -^ L ' — -_ - ! i ! - ° �� ' | | . | � ' � | | � | ' ' � i ' - - -' ! | l • � • � � � ! ! � ! ' � ' � ` � . - • ` | | ' | . � -- - � - ' - ----- _ -- - - - -- -- � ! 4'5 : -- - - - -- - - - ! ` i ! ` | i 51 1 11111W . E 1 .. 11 _ t 4.1ww V.4 ■ 1.0 aLt �- '77 r „ I , ..1' 7 ......1 4 7tr 7 77 1 44 7 11 771r. 111 NM ', • NY' 0; rf • F77 TTijJr I 1 Efl61- q r v36n 03/11303 , 77 4 FifhT0014V1 1%140 I k I 1.; .1 , `I) .3 4 MODEL 150A SPEED RANGE HORSEPOWER RPM TIP SPEED FPM ;ones 0" SP r / SP IA" SP %" SP Si" SP 3/4" SP 3 A" SP %" SP 1" SP 11/4" SP 1% SP 1%" SP CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM BHP BHP 3ones BHP •onesl BHP 3ones BHP 3ones BHP ;ones! BHP 3ones BHP 3ones BHP 3ones BHP ;ones( BHP 3ones BHP 3ones I 540 2403 1222 86 4.0 1 04 3.4 1604 I I I I I I 1 1 I 1 570 2537 1289 967 4.51.04 3.9 1.05 1 1 I I I I 1 1 1 1 610 2715 1380 1078 5.11.05 4.61.06 1 1 I I I I 1 1 1 1 640 2048 1448 1162 664 5.6 1.06 5,11.06 4,6 1.06 1 I •• l I I 1 1 1 1 670 2982 1516 1245 841 6.01.07 1584 5.6 1.07 1327 5.01.07 987 1 I I I I 1 I I 1 700 3115 3249 8,4 1.08 1651 6.1 1.08 1408 5.4 1 .08 1097 1 504 I I I I 1 1 1 1 730 6.81.09 6.5 1.09 5.9 1.09 5.81.08 1 I I I 1 1 1 1 780 3471 1765 1540 1282 786 7.6 1.11 7.3 1.11 6.81.12 6.51.10 I I I I 1 I 1 1 830 3694 1878 1671 1432 1080 512 8.31.14 0.11,14 7.6 1.14 7.2 1.14 7.2 1.11 I I I 1 1 1 860 3827 1946 1745 1516 1219 671 8.8 1 .15 8.6 1.15 8,1 1 .10 7.7 1.15 7.6 .13 1 I I 1 1 1 910 4050 2059 1869 1657 1405 972 487 9.61.18 9.41.18 9.11.10 8.6 1.10 8.4 1.17 8.4 1.14 I I 1 1 1 1 930 4139 2104 1918 1712 1481 1094 584 10.0 .19 9.7 .19 9.4 .20 8,9 ,20 8.7 .19 8.7 .16 LC Lin _ 980 4361 2217 2040 1849 1655 1359 845 412 10.91.22 10.71,23 10.41 .23 9.9 1 .23 9.4 1,23 9.4 1.20 9.4 1 .18 I 1 1 1 1 1020 4539 2307 2137 1957 1763 10.71.26 1507 10.21.26 1105 10,11.24 647 10,11,21 1 1 1 1 1 11.71 .25 11.41,26 11.11.26 1050 4673 2375 2210 2038 1848 1619 1278 805 393 12.21 .28 12.01 .28 11.71 .28 11.31 .28 10.81 .28 10.61 .27 10.61 .24 10,61 .21 1 I 1 1 1130 5029 2556 2402 2249 2072 1907 1647 1290 848 466 13,81 ,34 13.61 .35 13,41 .35 13,01 ,35 12.51 ,35 12.11 .35 12.01 .33 12.01 ,29 12.01 .27 1 1 1 1160 5162 2624 2474 2327 2155 1988 1757 1453 1003 643 14.4 .37 2737 14,21 .381 2592 14.01 .38 2453 13.7 .38 2991 13.21 .38 2127 12.71 .38 1945 12.51 .37 1701 12,51 .33 1329 12.51 . 917 1 562 1 1 1210 5385 15.51 .42 15,21 .43 15.01 .43 14.71 .43 14,31 .43 13.81 .43 13,51 .43 13.5 .40 13.51 .38 13.51 .34 1 1 1250 5563 2828 2687 2552 2399 2240 2085 1848 1554 1122 796 440 16.31 .47 2986 16.01 .47 2852 15.81 .47 2725 15,51 .48 2586 15.11 ,48 2435 14.71 .48 2284 14.31 .48 2112 14.11 .46 1888 14.11 .41 1573 14.11 .38 1161 14.11 .36 853 1 516 1320 5874 17.61 .55 17.41 .55 17.21 .55 17.01 ,56 16.61 .56 16,2 .58 15,81 .56 15.41 .56 15.41 .53 15.41 .48 15,41 ,45 15.41 .43 1350 6008 6186 3054 2923 2798 2665 2517 2370 2217 1996 1735 1355 1011 694 18.21 .59 3144 18,01 .59 3018 17.81 .59 2896 17,61 .60 2770 17.31 ,60 2628 16.91 .60 2483 16,41 ,60 2352 16,11 .60 2146 15,91 .58 1937 15.91 .54 1613 15,91 .50 1216 15.91 .47 924 1390 19.0 .64 18,8 .64 18.6 .65 18.4 .65 18.2 .66 17.8 .68 17,4 ,66 17.0 .68 16,6 .65 16.6 .62 16.6 .56 16.6 ,53 1430 6364 3235 3112 2993 2874 2735 2595 2495 2296 2085 1830 1477 1133 19.81 .70 19.61 .70 19,41 .70 19.21 ,71 19.01 .71 18.71 .72 18,31 .72 2599 17.91 .72 2471 17.61 .71 2271 17.41 .69 2076 17.41 .65 1781 17.41 .60 1412 1480 6586 3348 3229 3113 2999 2869 2734 21,01 .77 21.01.78 20,01.78 20.01 .78 20.01 ,79 19,81 ,79 19,41 .80 19,11 .80 18,81 .79 18.51:79 18,4 .75 18.41',70 1520 6764 3439 3322 3210 3099 2975 2844 2713 2590 2423 2224 1997 1687 22.01 .84 21.01.84 21,01.84 21.01 .85 21.01 .85 21.01 .86 20.01 .86 20.01 .86 2697 19,71 .86 2564 19,41,86 2372 19,21 .84 2188 19.21 .80 1910 1560 6942 3529 3416 3306 3198 3081 2952 2825 22.0 .91 3642 22.0 .91 3533 22,0 .91 3425 22.0 .92 3321 22.0 .92 3212 22.01 .93 3087 21,01 .93 2964 21,01 .93 2840 21,01 .93 2729 20.01 .93 2562 20.01 .92 2373 20,01 ,89 2178 1610 7165 23,011.00 23.011,00 23.011,00 23.011,01 23.011,01 23,011.02 22.011.02 22,011.02 22,011.02 21,011.02 21.011.02 21.011,01 1670 7432 3778 3672 3568 3467 3366 24,011,1224,011,13 3248 3128 24.011,14 3009 23,011.14 2890 23,011,14 2773 23,011,14 2598 23,011,14 2420 22.011,13 25.011,11 25,011,12 24,011.12 24,011.12 NOMINAL THICKNESS WHEEL DIA. (IN.) DAMPER SIZE (IN.) ROOF OPENING (IN.) CURB SIZE (IN.) AVG. SHIP WT. (LBS.) CURB CAP SKIRT MOTOR COVER .064 .050 .064 17 16 x 16 16.25 22 x 22 75 20 PERFORMANCE DATA 25'/. k g--- 24 SO. I.D. -- ►��2rh omen CtlnrVW rnn4r SP JonnFan certifies that the NOCR models shown heroin are licens• ed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publica. lion 211 and AMCA Publication 311 and comply with the require. menls of the AMCA Certified Ratings Program. Those powered ventilators are L available as U.L. 705 listed models. Those powered ventilators are listed by the Canadian Sian. dards Association Testing Labor• glories as approved, DIMENSIONAL DATA NOTES: 1. BHP door not Include boil drive losses. Porlormanco is for unit withou Intel ducts. 2. The sound ratings shown are loudness values in Ian sonos al 51t. (1.5m) In a hemispherical free hold calculated per AMCA Standard 301. Values shown are for Installation Typo A: free inlet fan sono levels NOTE: Outside dimensions of dampers are models). V" less than size shown (all Catalog 10 -109 I Page 5 Page 2 / Catalog 10.109 .. ..The. NBCR centrifugal belt driven roof ex- hauster was developed to meet present day demands for efficient performance and re- duced energy consumption. The improved performance, coupled with JennFan's long standing reputation as the leading manufac- turer of quality air moving products, provides value unequaled in the industry. Exterior Features: • Rugged, corrosion resistant, spun aluminum housing and aluminum curb cap; stainless steel fastenings. • New fasteners engage in slots eliminating the need to remove hardware completely from unit to access motor (series 120A through 310A). Internal Features: • Prelubricated ball bearing drive and motor mounting in a force cooled compartment isolated from exhaust airstream for maximum motor life. • Vibration isolators are in combination shear and compres- sion for extra quietness (series 150A and above). • Heavy duty cast iron adjustable pulley to permit simple speed variation is standard. • Static dissipating V belts. • Non - overloading, all aluminum wheel and hub dynamically and statically balanced to assure long life and quiet operation. • •Units pre - tested and shipped with motor and drive. installed. • "Motor prewired to junction box. • External aluminum wiring post provided for electrical conduit. • Single screw adjustment of belt tension to maintain cons- tant air delivery. • Optional: Automatic, spring - loaded belt tightener maintains constant fan RPM and air delivery, minimizing belt wear- ing slip. 'Except 5 HP and 7'/: HP units, motors will be shipped separately. "Except explosion resistant. amca CERTIFIED RRTIRG$ AIR movimim anocomaoi assocmnonInc D 'ouno jut The spun aluminum NBCR exhauster is t available in seven sizes with capacities from 600 through 32,900 CFM. The NBCR is available with a complete line of optional ac- cessories and is manufactured under strict quality assurance standards to insure years of maintenance free operation. Copyright ® 1991 SnyderGeneral Corporation, Minneapolis, Minnesota. All rights reserved throughout the world. "Bulletin Illustrations cover the general appearance of SnyderGeneral Corporation products at the time of publication and we reserve the right to make changes In design and construction at any time without notice;" JennFan certifies that the NBCR models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and pro- cedures performed In accordance with AMCA Publication 211 and AM- CA Publication 311 and comply with the requirements of the AMCA Cer- tified Ratings Program, Mar 02, 1994 AL NOAH 3414 A STREET S.E. AUBURN, WA 98002 Dear Permit Holder: City of Tukwila John W Rants, Mayor Department of Community Development Rick Beeler, Director RE: CITY OF TUKWILA MAINTENANCE SHOP Our records indicate that on Apr 27, 1994 one hundred and eighty days will have passed with no inspections having been called for under Tukwila Mechnical Permit Number M93 -0170. Unless you call for an inspection, or obtain a written extension from the Tukwila Building Official prior to that date, your above referenced permit will become null and void on Apr 27, 1994. If your project is complete please call fox-final inspection. If you are actively working on your project please contact our office. If you have any questions or need further information to obtain an extension on your permit please call the Tukwila Building Divison at 431 -3670. Sincerely, ,o,„„ • Denise Millard Permit Coordinator Department of Community Development 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 4313670 • Fax (206) 4313665