Southcenter Design Manual
Adopted by Res 1831
Exhibit A
City of Tukwila
Southcenter Design
Manual
June 2, 2014
05/12/2014
Southcenter Design Manual
Table of Contents
Introduction
Site Design Elements
1. Site Design 1
2. Service areas and mechanical equipment 3
3. Lighting 6
4. Walls and Fences 7
5. Open Spaces 10
Building Design
6. Architectural Concept 12
7. Entrances and Doors 13
8. Building facade — Base and Top 17
9. Corner Treatments 23
10. Building massing 24
11. Building details and elements 32
12. Building Materials and Colors 35
13. Windows 40
14. Weather protection 43
15. Blank Walls .. 46
16. Parking Structures 48
03/02/14
Southcenter Design Manual
INTRODUCTION
Purpose
The Southcenter Design Manual provides policy guidance on site and building design. The guidelines support
and complement the community vision described in the Southcenter Subarea Plan, and provide a flexible
tool for quality and innovation. This document is intended to supplement and expand upon the design
requirements found in Chapter 18.28 Tukwila Urban Center (TUC) Zoning standards.
This document provides City staff, the Board of Architectural Review (BAR), and the public a common basis
for the evaluation of design and development issues during the design review and approval process. The
Manual does not specify a particular style of architecture or design but is intended to guide applicants in
creating an appearance of greater consistency and design quality within the Southcenter District.
Organization
The Southcenter Design Manual is organized by design topic. The general structure is:
1. DESIGN TOPIC (E.G. WINDOWS)
intent Statement
• Provided to guide the application of criteria to differing site circumstances in a consistent manner.
Design Criteria
A. Design Criteria: General requirements to be met by development
1. Example measures that guide development design to meet the design topic intent and design
criteria above. Graphic and written descriptions are provided.
For each Design Topic there are one or more Design Criteria, which can be general in nature. The Design
Criteria explain the requirements for development proposals. They are the decision criteria by which the
Director or Board of Architectural Review will decide whether to approve, condition or deny a project.
The examples and explanations beneath, which augment each Design Criteria, provide guidance to the
project applicant developing the project, to City staff in reviewing a project proposal, and the decision maker
in determining whether the project meets the Design Criteria. These are intended to provide guidance and
possible solutions for the criteria but should not be seen as the only solution. There may be specific
requirements to include or avoid.
Photographs and illustrations appear beneath the item they are intended to explain.
Interpretation
Where the word "shall" or "must" is used it is intended to be a mandate; and where the word "should" or
"encouraged" is used, it is intended to be a recommendation. in determining the degree of applicability of
design criteria or in case of conflict or site impracticality, priority should be given to criteria related to the
"public realm." Not all criteria will be applicable to every project.
This Manual describes, in clear terms, those features that are to be addressed in the design of projects. It is
evident that the criteria could generate numerous solutions. Varied and imaginative designs are certainly
Southcenter Design Manual adopted- attchmt 5 -28 -14 i 03/25/2014
Southcenter Design Manual
encouraged. Photographs are often included as visual examples for design and review purposes. They are
not intended to be specific examples to be replicated.
Where an addition to or expansion of an existing building triggers design review the new construction shall
meet all relevant criteria. In addition limited exterior modifications to the existing structure may be required
to aesthetically unify the new and existing portions of the structure and better meet the design criteria.
Southcenter Design Manual adopted - attchmt 5 -28 -14
ii 03/25/2014
Southcenter Design Manual
SITE DESIGN /ELEMENTS
1. SITE DESIGN
Intent
• To encourage site design in which the organization is easily understood, appropriate to the area,
takes advantage of unique opportunities, and is a positive element in the architectural character of
the District within which it is located.
Design Criteria
A. Design sites to take advantage of special opportunities and mitigate impacts while
demonstrating a unifying organization that accomplishes the following goals:
1. Facilitate better traffic circulation by connecting through streets, where applicable.
2. Provide a safe, convenient, and connected pedestrian access system. For example, redevelopment
of a superbiock site should strive to create a pedestrian- friendly environment within the internal
Layout. In addition to providing any required new streets, this can be accomplished by defining a
network of pedestrian walkways that serve as a "grid ", connecting these walkways to uses with the
site and to the larger street network, and creating smaller parking areas in place of one large parking
lot.
3. Encourage buildings to complement adjacent activities and visual character (where desirable).
4. Arrange buildings to enhance the site's street frontages and the overall pedestrian environment.
For example, on sites where large retail stores are planned, small retail shops may be clustered
along the street with parking behind that serves both the small and large retail uses.
5. Incorporate open space and landscaping as a unifying feature.
6. Incorporate screening, environmental mitigation, utilities, and drainage as positive design elements.
7. Incorporate opportunities for joint development of sites where there is potential for common
building walls, shared driveways, landscaping, or other shared facilities.
8. Use site design to take advantage of and/or enhance views of or access to the river, pond,
surrounding hillsides, and mountains, where feasible.
Southcenter Design Manual adopted - attchmt 5 -28 -14
1 03/25/2014
Southcenter Design Manual
Good internal circulation
and connections to
adjacent sites-
Parking Jot landscaping
and buffering
Pedestrian- oriented Centralized
street frontages pedestrian space
Use Site Design to break up super blocks.
Southcenter Design Manual adopted - attchmt 5 -28 -14 2 03/25/2014
Southcenter Design Manual
2. SERVICE AREAS AND MECHANICAL EQUIPMENT
Intent
• Minimize the potential negative impacts of service elements through thoughtful siting and screening
while meeting functional needs
Design Criteria
A. Service element Location and design.
Provide designated areas for service elements (refuse and disposal) that meet the following standards:
1. Locate service elements to minimize the negative visual, noise, odor, and physical impacts to the
street environment, adjacent (on and off -site) residents or other uses, and pedestrian areas. All
service entrances and associated loading docks and storage areas should be located to the side or
rear of the building unless all facades face a public street in which case locate them in the least
visible location or screen them with landscaping. if possible integrate service enclosures into the
building itself;
2. Minimizing impacts to adjacent residential units is the highest priority in determining appropriate
service element location and treatment, followed by impacts to office and retail uses;
3. Pave the designated spot for service elements with concrete for durability and ease of
maintenance;
DUMPSTER
LOCATED AT
REAR OP
SRE
SCREENED
4EGNMMaCat
ltk
EQUIPMENT
4° ii),444\
veki,
0
Appropriate service area location and enclosure example.
4. Enclose and screen service areas visible from any street, pathway, pedestrian - oriented space or
public parking area (alleys are exempt) with a durable wall or fence at least 6 feet high. Use
materials and detailing consistent with primary structures on -site. Acceptable materials include
brick, concrete block or stone;
5. Locate and configure collection points so that the enclosure gate swing does not obstruct
pedestrian or vehicle traffic, or does not require that a hauling truck project into any public right -
of -way;
6. When service elements are visible from the street, dwelling units, customer parking areas, or
pathways, soften the appearance of the sides and rear of the enclosure with landscaping
Southcenter Design Manual adopted- attchrnt 5 -28 -14
3 03/25/2014
Southcenter Design Manual
B. Loading Docks and Service Bays: Buildings containing loading docks or automotive service bays
shall be designed to minimize their visibility from the public realm.
1. Either orient the service bay doors in the direction least visible from the public realm or screen the
doors with walls, trellises or landscaping.
2. Framing elements such as trellises and trim around the edges of service bay doors are
recommended to add depth and detail to the automobile scaled facade.
C. Utility meters, electrical conduit, and other service utility apparatus.
1. Locate and /or design these elements to minimize their visibility to the public. Project designers are
strongly encouraged to coordinate with applicable service providers early in the design process to
determine the functional requirements for the equipment and the best approach to meeting these
standards.
2. If such elements must be mounted in a location visible from a street, pedestrian pathway, common
open space, or shared auto courtyard screen them with vegetation or architectural features,
Good and bad utility meter configurations. The examples on the left are consolidated and somewhat screened by
landscaping elements, whereas the right examples are exposed and degrade the character of these townhomes.
D. Rooftop equipment screening.
Screen all rooftop mechanical equipment so that it is not visible from public streets and sidewalks
within 300 feet of the subject property, except from points of view in excess of 10 feet above finished
site grade of the subject property.
. The first preference is to either place the equipment where it is not visible due to roof forms or
parapet walls.
2. If equipment must be placed where it is visible screen it with elements that are architecturally
compatible with the building design.
3, Design the screening using materials, architectural styles, colors and /or other elements from the
facade to integrate the screening into the building's architecture.
Southcenter Design Manual adopted - attchmt 5 -28 -14
4 03/25/2014
Southcenter Design Manual
4. In the design of screening enclosures, use dimensional increments of window spacing, mullion
spacing, or structural bay spacing taken from the facade composition.
E. Downspouts.
1. Where possible, downspouts should be concealed within walls while meeting the requirements of
plumbing codes and providing for maintenance.
2. The location, spacing, materials, and colors of exposed downspouts, gutters, scuppers, and other
visible roof drainage components should be incorporated into the architectural composition of the
facade and roof; haphazard placement should be avoided. Half round gutters and round
downspouts are recommended as a type appropriate for most architectural styles. Corrugated
downspouts should not be used.
Screening example of rooftop mechanical equipment.
Southcenter Design ManuaL adopted- attchmt 5 -28 -14
5 03/25/2014
Southcenter Design Manual
3. LIGHTING
Intent
• To design site lighting that accents the architecture, improves safety and avoids impacts to adjacent
properties and passersby.
Design Criteria
A. Design site lighting to promote safety as well as enhance the nighttime appearance of buildings
and landscaping.
1. Commercial buildings and landscaping can be illuminated indirectly by concealing light features
within buildings and landscaping to highlight attractive features and avoid light intrusion into
neighboring properties.
2. Bollard mounted lighting and stair lighting are recommended for low -level illumination of walkways
and landscaped areas.
3. Illuminate public entrances at night to enhance safety and visibility.
B. Avoid glare from unshielded or undiffused light sources.
1. Small decorative "glow" elements within a luminaire such as bollard mounted lighting or stair
lighting are permitted to emit a low amount of light above the horizontal.
2. Prevent spillover light and glare from being visible to pedestrians, motorists, and nearby residential
dwelling windows through shielding and careful placement. Glare can create a major safety hazard
for motorists.
3. Illumination levels of facade uplighting, roof wash lighting and landscape uplighting should use
lower brightness levels where the illuminated facades, roofs or landscaping face residential
buildings, except across wider streets or boulevards with landscaped medians and street trees.
Southcenter Design IVranual adopted- attchmt 5 -28 -14
6 03/25/2014
Southcenter Design Manual
4. WALLS AND FENCES
Intent
• To design walls and fences that are compatible with the building, improve the appearance of the site
and improve safety.
Design Criteria
A. Design walls and fences to create a sense of entry and enhance the street frontage.
1. Frontage walls may occur as garden walls, planter walls, seat walls, or low retaining walls. Seating
walls should be between 15 " -18" in height and a minimum of 18" wide to provide comfortable
seating.
2. Entrances and pedestrian "gateways" should be announced by posts or pilasters, and may be
combined with trellises, special landscaping, decorative lighting, public art or other special
features.
Low walls as a transitional, decorative element to soften the wall.
Low walls with landscaping to separate public space from semi- private space.
Southcenter Design Manual adopted- attchmt 5 -28 -14
7
03/25/2014
Southcenter Design Manua!
Decorative masonry and stone walls to define space.
B. Design walls and fences to screen unsightly portions of the site and enhance security.
1. Screening fences and walls should be constructed of materials that are compatible with the
architecture and character of the site. Natural colors, a cap or top articulation, and related
dimensional post spacing increments should be used at screening fences to enhance compatibility.
2. All walls should have a cap and base treatment.
3. Design elements should be used to break up long expanses of uninterrupted screening walls, both
horizontally and vertically. Walls should include design elements such as textured concrete block,
interlocking "diamond" blocks, formed concrete with reveals, or similar materials. Landscape
materials should also be used to provide surface relief.
4. Use of security fences should be minimized, and limited to special locations where additional
security is necessary. Such security fences should not exceed 6 feet in height.
5. Security fences should be designed to maintain a visually open character to the extent possible.
This may be accomplished by using metal picket or open grille fencing or by mounting metal picket
or open grille fencing on top of a low masonry wall.
6. Seek Fire Department review and approval for all bollards protecting Fire Department equipment.
Southcenter Design Manual adopted- attchmt 5 -28 -14
8 03/25/2014
Southcenter Design Manual
Good screening wall examples. Landscaped trellis wall as a visual screen (left). The trash enclosure (right) uses a
decorative pattern of concrete blocks and metal doors that complement the architecture of the adjacent building.
Southcenter Design Manual adopted- attchmt 5 -28 -14
9 03/25/2014
Southcenter Design Manual
5. OPEN SPACE
intent
• Provide safe, attractive, and usable open spaces that promote pedestrian activity.
• Create open space that enhances the setting and character of residential, commercial, and mixed -use
development.
Design Criteria
A. Pedestrian Space Design Guidelines (for commercial uses).
1. Provide a variety of seating options, including benches, seating steps, planters, landscaping
features, or low walls. When designing seat walls with straight edges of more than six feet in
length, add detailing that will prevent damage from skateboards.
2. Provide areas of sun and shade for year -round climatic comfort, and, where desired, shelter and
night lighting to encourage public activity and ensure safety.
3. Include specimen trees and seasonal plantings.
4. Landscaping should not act as a visual or physical barrier to adjacent sidewalks.
5. Include artwork, water features, trellises or shelters, and decorative paving in pedestrian spaces.
6. Public gathering places should be equipped with 115- and 220- volt outlets as appropriate for
entertainment or commercial use.
7. Detail public gathering places and other publicly accessible areas with decorative, pedestrian -
scaled site furnishings and equipment such as seating, freestanding planters, ornamental solid
waste and recycling receptacles, bike racks, drinking fountains, pergolas, trellises, heaters,
umbrellas, wind screening, and decorative bollards.
8. Components of site furnishings should be made of durable high quality materials such as painted
fabricated steel, painted cast iron, painted cast aluminum, and integrally colored precast concrete.
Recycled materials should be used so long as the finish or look of the material is consistent with or
similar to the finishes prescribed above. Metal surfaces should be coated with highly durable
finishes such as aliphatic polyurethane enamel.
9. Landscape structures and sculptural objects in pedestrian spaces should reference the human scale
in their overall massing and detailing.
B. Private open space for residential units.
1. Create privacy between units with balconies either structurally or having at least 10 feet horizontal
space between balconies.
Southcenter Design Manual adopted- attchmt 5 -28 -14
10 03/25/2014
Southcenter Design Manual
C. Common open space for residential units.
1. Provide individual entries onto common open space from adjacent ground floor residential units.
Small, semi - private open spaces for adjacent ground floor units that maintain visual access to the
common area are encouraged to enliven the space. Use low walls or hedges (less than 3 feet in
height) to provide clear definition of semi- private and common spaces.
Common open space examples that integrate semi- private spaces with direct unit access to the common open
space.
Southcenter Design Manual adopted- attchmt 5 -28 -14
11 03/25/2014
Southcenter Design Manual
BUILDING DESIGN
6. ARCHITECTURAL CONCEPT
Intent
• To encourage building design in which the organization is easily understood, appropriate to the site,
and is a positive element in the architectural character of the District within which it is located.
Design Criteria
A. Develop an architectural design expression that unifies the massing and components of a
structure or structures on a site into a cohesive and consistent thematic or stylistic architectural
character or style that is responsive to the functional requirements of the development.
1. Example of axial symmetry, or more formal design organization, in a multi - family building.
2. Example of asymmetry, or more informal composition, in a commercial building.
5outhcenter Design Manual adopted- attchmt 5 -28 -14 12
03/25/2014
Southcenter Design Manual
7. ENTRANCES AND DOORS
Intent
• Ensure a welcoming public face to buildings with well designed, appropriately scaled, and easy to
find entrances.
• Entrances should be visually prominent features in the design of a building.
• Design retail and commercial entries to create an open atmosphere that draws customers inside, and
residential entries that are welcoming and provide a graceful transition between the public and
private realm.
Design Criteria
A. Primary entrances are among the most visible and characteristic features of a building. Locate
and design the main entrance door(s) and the surrounding frame to represent the overall style
and architectural character of the building.
1. The primary entrance may be:
a) marked by a taller mass above, such as a modest tower or portico (roofed entrance supported
by columns) that protrudes from the rest of building surface;
b) accented by special architectural elements, such as columns, overhanging roofs, a permanent
architectural canopy utilizing materials from the primary building, projecting canvas or fabric
awnings, and ornamental light fixtures;
Examples of permanent architectural canopies
Southcenter Design Manual adopted - attchmt 5 -28 -14
13
03/25/2014
Southcenter Design Manual
c) indicated by a recessed entry opening onto the public sidewalk or a forecourt. This design could
be incorporated into commercial, residential, or mixed -use buildings. Recommended treatments
include special paving materials such as ceramic tile; ornamental ceiling treatments (for recessed
entries), such as coffering; decorative light fixtures; and decorative door pulls, escutcheons,
hinges, and other hardware.
MD IM .11=iMMIMO.
SACK C,K SI•=WU K
A recessed entry could be fully enclosed from above or could come in the form of a forecourt (right image)
2. Residential developments may use the following entry treatments:
a) Stoop. A stoop is an entrance stairway to a residence typically constructed close to the sidewalk.
Stoops may feature a portico entrance at the top of the stair. Multiple stoops may be combined
to increase the scale of the entrance. Setback areas are typically landscaped.
Stoops
Southcenter Design Manual adopted- attchmt 5 -28 -14 14
03/25/2014
Southcenter Design Manual
Stoop examples.
b) Porch. A porch is a roofed space, open along two or more sides and adjunct to a building,
commonly serving to shelter an entrance and provide a private outdoor space appended to a
residence. Porches may serve multiple entrances. Setback areas are typically landscaped.
,! ►+t *a0 YI A4
Porch
k.,,t.. !,t,a„
c) Front door. A front door features a residence's main entrance with a deep setback, creating a
gracious open space along the property frontage. Setback areas are typically landscaped. Special
paving should be used to enhance and define the entrance.
3. Ground floor multi - family residential units should have dedicated entrances wherever possible.
Southcenter Design Manual adopted - attchmt 5 -28 -14 15
03/25/2014
Southcenter Design Manual
B. At mixed -use buildings, clearly distinguish entrances to residential, office or other upper story
uses from retail entrances.
1.
Residential entries distinguishable from commercial entries.
Use different materials, building forms, door styles, and/or building perforations in
retail /commercial spaces than residential entrances.
2. Accent the entrance with architectural elements such as clerestory windows, sidelights, and
ornamental light fixtures, and identify it with signage and/or address numbering.
3. The entrance may be recessed into a vestibule or lobby distinguishable from storefronts.
C. Secondary Entrances: Design side or rear building entries to be consistent with but visually
secondary to main entrances.
Side or rear entries (left) should be consistent, but secondary to the primary entrance (right).
1. Use materials and proportions to architecturally relate the side or rear entry to the design of the
front entry.
2. Secondary entries should be enhanced with detailing, trim and finish consistent with the character
of the building.
3. Large multi- tenant buildings may have multiple main entrances.
Southcenter Design Manual adopted- attchmt 5 -2844 16
03/25/2014
Southcenter Design Manual
8. BUILDING FACADE - BASE AND TOP
Intent
• To ensure that individual elements of a facade relate to the facade's overall design, articulation, and
organization.
• To reduce the scale of large buildings.
• Encourage prominent roofiines that give buildings an attractive and distinctive top, contribute to the
character of the area, and are consistent with the type of building function and uses.
• Encourage the use of sloped roofs for residential buildings to shed rain and snow and provide shelter.
Design Criteria
A. Create a building base where the horizontal articulation of the lower part of a building facade's
design establishes a human scale for pedestrian users and passers -by, and aesthetically "ties" a
building to the ground.
1. Provide a building base treatment at both of the following scales on commercial buildings:
a) At the scale of the pedestrian (i.e. within the ground floor portion of the facade), a base
treatment should be created at a height between nine inches and six feet.
Examples of pedestrian- scaled building base treatments. Note the tilework below the storefront window in the left
image, concrete base in the middle and right images.
b) For multi -story buildings, at the scale of the building the facade of the entire ground floor for up
to the second floor, depending on the height of the building) should be designed to read as a
base that "anchors" the building (i.e., the portion of the facade above) to the ground.
Southcenter Design Manual adopted - attchmt 5 -28 -14
17 03/25/2014
Southcenter Design Manual
Base treatment examples for multi -story buildings.
2. Create the building base by any one or more of the following treatments:
a) A horizontal projection (or visible thickening) of the wall surface, which may be accompanied by
a change of material and /or color; this may be an exterior version of a "wainscot /'
b) A material and /or color change of the base wall relative to the building wall above. The base
material should be heavier (e.g. of darker color and /or a heavier or more permanent material)
than portions of the building above.
Examples of color and material changes to differentiate base of building
c) A horizontal architectural line or feature at or below the top of the first story, such as a belt
course, protruding horizontal band or secondary cornice (related to or repeating the pattern of
an upper cornice) separating the first two floors.
d) At non - residential buildings a ground level arcade with columns may be used to create a building
base. Column spacing should be regular, and related to the structural bay increment of the
building.
B. Create a "top" on buildings through a substantial horizontal articulation of the facade at the
uppermost floor of the building to provide an attractive facade skyline and complete the upper
facade composition.
1. Architecturally integrate this "cap" with any sloping roof volume (if used) that occurs above the
eave line.
2. Rooflines should reflect the architectural style of the building and be a distinctive design element.
Southcenter Design Manual adopted - attchmt 5 -28 -14 18 03/25/2014
Southcenter Design Manual
Examples of distinctive rooflines
Pitched and continuous sloping roof forms (i.e. without flat horizontal portions) including gable,
hip, and pyramidal roofs are encouraged.
Examples of pitched rooflines
4. Roof surfaces should be punctuated with varying roof forms to break up large massing of roof
surfaces and /or to provide opportunities to daylight interior spaces.
Examples of varying roof forms
Southcenter Design Manual adopted- attchmt 5 -28 -14 19
03/25/2014
Southcenter Design Manual
5. Ornament flat or shallow pitched roofs with shaped parapets, caps, or cornice treatments.
a) The primary cornice should be decorated or bracketed with parapets, finials, or simple
decorative panels or molding.
b) An architecturally profiled cornice and/or expressed parapet cap should be used to terminate
the top of the parapet wall.
c) Surface mounted cornices, continuous shading elements, or trellises should be used to
strengthen a parapet wall design.
d) Sheet metal parapet caps or coping should provide a formed (compound folded) overhanging
edge termination and a heavy gage sheet metal thickness selected to avoid "oilcanning"
distortion. Single layer, flush sheet metal parapet caps should riot be used. Finish should either
be of an unpainted ornamental metal such as copper, or painted to match adjacent wall surface.
Unpainted galvanized metal should not be used.
6. Roof overhangs for both flat and sloping roofs are encouraged to add depth, shadow and visual
interest.
a) Vertical roof edge fascia over eighteen inches in height should be subdivided or accented by
additional horizontal layers, stepbacks, trim, and other detailing.
Sauthcenter Design Manual adopted - attchmt 5 -28 -14
20 03/25/2014
Southcenter Design Manual
b) Brackets and corbels (i.e. decorative supporting pieces designed to bear the weight of projected
overhangs), or other expressed roof overhang supports (whether structural or nonstructural) are
encouraged to add richness to detailing. The spacing module of repeating supports should
relate to the building's structural bay spacing or window mullion spacing.
c) The soffit (i.e. the underside surface of the roof overhang) should be designed as a visible
feature and incorporated into the overall architectural composition. Soffit beams, coffers, light
fixtures and other design articulation are encouraged.
Top or "cap" examples — dramatic roof forms.
Southcenter Design Manual adopted - attchmt 5 -28 -14 21
03/25/2014
Southcenter Design Manual
Top or "cap" examples — various cornice lines.
Top or "cap" examples: Vertical modulation plus combined with changes in materials and detailing (left).
Distinctive sloped roof form (right).
Top or "cap" examples — horizontal modulation (upper level stepbacks).
Southcenter Design Manual adopted- attchmt 5 -28 -14 22
03/25/2014
Southcenter Design Manual
9. CORNER TREATMENTS
Intent
• To emphasize the importance of intersections through special design elements.
Design Criteria
A. Emphasize building corners at important intersections with a distinctive building element.
1. Appropriate building elements include:
a) Corner towers which are created by articulating a separate, relatively slender mass of the
building, continuing that mass beyond the height of the primary building mass, and providing
the top of the mass with a recognizable silhouette,
b) Projecting or recessed corner entrances with a distinctive roof or canopy element,
c) Distinctively shaped bay windows or balconies.
Southcenter Design Manual adapted- attchmt 5 -28 -14 23
03/25/20N
Southcenter Design Manual
10. BUILDING MASSING
Intent
• To ensure, through horizontal and vertical modulation, that the apparent height and length of a
building maintains the desired human scale and character for the Southcenter area.
• To reduce the scale of large buildings
• To encourage the design of building facades which incorporate interesting architectural details that
add variety to the facade, animate the street presence, and are attractive at a pedestrian scale.
Design Criteria
A. Facade articulation — commercial and mixed -use building facades. Employ at least three of the
following features at intervals no greater than specified by the applicable corridor type to
reduce the perceived scale of buildings and add visual interest:
1. Window fenestration patterns and /or entries;
2. Use of weather protection features;
3. Use of vertical piers or columns;
4. Change in roofline form;
5. Change in building material or siding style
6. Vertical elements such as a trellis with plants, green wall, or art element;
7. Providing vertical building modulation of at least 12 inches in depth if tied to a change in roofline or
a change in building material, siding style, or color;
8. Other design techniques that effectively reinforce the pattern of small shopfronts and /or
effectively reduce the perceived scale of the building and add visual interest.
9. Alternative designs will be considered provided such techniques effectively reduce the perceived
scale of the building and add visual interest from all observable distances. The City shall consider
the following in determining whether the treatment meets the intent of the guidelines:
a) Types of materials used and how they help to achieve the intent;
b) The type of articulation treatments and how effective they are in meeting the intent;
c) low effective the articulation treatments respond to the site's context and visibility (for
instance, side streets warrant greater flexibility than primary streets where facades are more
visible).
Southcenter Design Manual adopted - attchmt 5 -28 -14
24 03/25/2014
Southcenter Design Manual
Articulation ln crement
arf CENTER
Articulation increment
�Ar#icertaiF� p' lererne�t
Mill MIN khAlltitilliii111111
Entries and fenestration patterns
Vertical piers /columns
Weather protection elements
Facade articulation example
Southcenter Design Manual adapted- attchrnt 5 -28 -14 25
03/25/2014
Southcenter Design Manual
For retail facades, one way of meeting the articulation provisions is to design individual storefronts or increments to
look like separate buildings. Facades in these examples use different materials, colors, fenestration techniques,
rooflines, and weather protection elements.
Facade articulation examples for multi -story buildings. The ground level commercial facades employ entries and
fenestration techniques, vertical piers, and weather protection elements.
5outhcenter Design Manual adopted - attchmt 5 -28 -14 26
03/25/2014
Southcenter Design Manual
Unacceptable facade articulation techniques. Both examples use some articulation features, but they are
insufficient in meeting the intent of the guidelines.
B. Facade articulation — multifamily building facades. This includes single purpose multifamily
buildings and residential portions of mixed -use buildings. Employ at least three of the following
features at intervals no greater than specified by the applicable corridor type to reduce the
perceived scale of buildings and add visual interest:
1. Window fenestration patterns and /or entries;
2. Vertical building modulation. Minimum depth and width of modulation is 18 inches and four feet,
respectively, if tied to a change in color or building material and /or roofline modulation. Otherwise,
the minimum depth and width of modulation is 10 and 15 feet, respectively. Balconies may be used
to meet the modulation if they are recessed or projected from the facade by at least 18 inches.
Juliet balconies, and other balconies that appear to be "tacked -on" to the facade will not qualify for
this option unless they employ high quality materials and add visual interest to the facade;
3. Change in roofline;
4. Change in building material or siding style;
5. Building elements such as bay windows, porches, canopies, chimneys, or other repetitive features
that effectively articulate the facade;
6. Other design technique that effectively reduces the perceived scale of the building and adds visual
interest.
7. Alternative designs will be considered provided such techniques effectively reduce the perceived
scale of the building and add visual interest from all observable distances. The City shall consider
the following in determining whether the treatment meets the intent of the guidelines:
a) Types of materials used and how they help to achieve the intent;
b) The type of articulation treatments and how effective they are in meeting the intent;
c) How effective the articulation treatments respond to the site's context and visibility (for
Southcenter Design Manual adopted - attchmt 5 -28 -14
27 03/25/2014
Southcenter Design Manual
instance, side streets warrant greater flexibility than primary streets where facades are more
visible).
111111111Ply
11 11 11
11 11 11
11 11 11
11 11 11
11
11
11 11
I11 wJ I1
Multifamily facade articulation example.
11 11
11 11
Examples of multifamily facade articulation.
C. Major Vertical Modulation Increment. Incorporate at least one of the following design
elements at intervals no greater than specified by corridor type to reduce the perceived scale of
buildings and add visual interest:
1. Provide major vertical building modulation at least 10 feet deep and 20 feet wide. Such
modulation may be recessed from the wall or project from the wall. For multi -story buildings the
modulation must extend through more than one -half of the building floors;
2. Use of a contrasting vertical modulated design component featuring all of the following:
a) Component extends through all floors above the first floor fronting on the street. Exception:
upper floors that are stepped back more than 10 feet from the facade are exempt;
b) Utilizes a change in building materials that effectively contrast from the rest of the facade;
c) Component is modulated vertically from the rest of the facade by an average of 6 inches; and
Southcenter Design Manual adopted-attchmt 5 -28 -14
28 03/25/2014
30' max.
30' max.
30' max.
111111111Ply
11 11 11
11 11 11
11 11 11
11 11 11
11
11
11 11
I11 wJ I1
Multifamily facade articulation example.
11 11
11 11
Examples of multifamily facade articulation.
C. Major Vertical Modulation Increment. Incorporate at least one of the following design
elements at intervals no greater than specified by corridor type to reduce the perceived scale of
buildings and add visual interest:
1. Provide major vertical building modulation at least 10 feet deep and 20 feet wide. Such
modulation may be recessed from the wall or project from the wall. For multi -story buildings the
modulation must extend through more than one -half of the building floors;
2. Use of a contrasting vertical modulated design component featuring all of the following:
a) Component extends through all floors above the first floor fronting on the street. Exception:
upper floors that are stepped back more than 10 feet from the facade are exempt;
b) Utilizes a change in building materials that effectively contrast from the rest of the facade;
c) Component is modulated vertically from the rest of the facade by an average of 6 inches; and
Southcenter Design Manual adopted-attchmt 5 -28 -14
28 03/25/2014
Southcenter Design Manual
d) Component is designed to provide roofline modulation; or
3. Facade employs building walls with contrasting articulation that make it appear like two distinct
buildings. To qualify for this option, these contrasting facades must employ both of the following:
a) Different building materials and/or configuration of building materials; and
b) Contrasting window design (sizes or configurations).
4. Alternative treatments will be considered provided the design meets the intent of the guidelines.
Elements to consider are the level of detailing, quality of building materials, types of articulated
features, and integration with/or enhancement of, the surrounding context (considering views
from all publicly observable locations within the area).
X = Maximum modulation increment is specified by corridor
MEETS REQUIREMENT
DOES NOT MEET
REQUIREMENT
Major vertical building modulation
(at least 10' deep by 20' wide)
MEETS REQUIREMENT
Illustrating Major Vertical Modulation Increment standards.
Southcenter Design Manual adopted- attchmt 5 -2844 29
03/25/2014
Southcenter Design Manual
The above examples do not meet the modulation increment standard. In the left image, the modulated
features aren't enough to mitigate the continuous massing of the upper level of the building. The right image
includes small scale vertical modulation, but over an extensive width, it isn't sufficient enough to effectively
reduce its perceived width.
Acceptable examples. The left image meets the criteria for (2) above for a contrasting vertical modulated
design component. The right image meets the criteria for (1) above for vertical building modulation at least
10 feet deep and 20 feet wide.
Acceptable examples. Both large scale retail examples above use major vertical building modulation features
(1) and most or all of the features of a vertical modulated design component (2).
Southcenter Design Manual adopted- attchmt 5 -28 -14 30
03/25/2014
Southcenter Design Manual
Acceptable "alternative" examples. The left image includes five articulated facade intervals — with the central
component using different materials, fenestration, and roofline modulation. The right image uses a combination of
vertical and horizontal modulation and a change in building materials to meet the intent of the standards.
Southcenter Design Manual adopted- attchmt 5 -28 -14
31 03/25/2014
Southcenter Design Manual
11. BUILDING DETAILS AND ELEMENTS
Intent
• To encourage the incorporation of design details and small -scale elements into building facades that
are attractive at a pedestrian scale.
Design Criteria
A. Employ detail elements from each of the three categories below on facades facing a street,
featuring a customer entry, or featuring the primary residential entry. For non- residential and
mixed -use buildings include at least one detail from each category within each facade
articulation increment (see TMC 18.28.200) and for residential buildings include at least two
detail features from each category within each articulation increment. For example, a
residential building with 120 feet of street frontage with a facade articulated at 30 -foot
intervals will need to include two of the detail elements from the three categories below within
each of its four facade segments.
1. Window and /or entry treatment:
a) Display windows divided into a grid of multiple panes;
b) Transom windows;
c) Roll-up windows /doors;
d) Other distinctive window treatment that meets the intent of the standards;
e) Recessed entry;
f) Decorative door;
g) Landscaped trellises or other decorative element that incorporates landscaping near the building
entry; or
h) Other decorative or specially designed entry treatment that meets the purpose of the standards.
2. Building elements and facade details:
a) Custom- designed weather protection element such as a steel canopy, cloth awning, or
retractable awning;
b) Decorative, custom hanging sign(s);
c) Decorative building- mounted Tight fixtures;
d) Bay windows, trellises, towers, and similar elements; or
e) Other details or elements that meet the intent of these standards.
3. Building materials and other facade elements:
a) Use of decorative, high quality building materials. Examples include decorative use of brick, tile,
or stonework;
5outhcenter Design Manual adopted- attchmt 5 -28 -14
32 03/25/2014
Southcenter Design Manual
b) Artwork on building (such as a mural) or bas - relief sculpture;
c) Decorative kick - plate, pier, beltcourse, or other similar feature;
d) Hand - crafted material, such as special wrought iron or carved wood; or
e) Other details that meet the purpose of the standards.
4. "Custom," "decorative," or "hand - crafted" elements referenced above must be distinctive or "one -
of -a -kind" elements or unusual designs that require a high level of craftsmanship.
5. Alternatives will be considered provided the number, quality, and mix of details meet the intent of
the standards.
Detail examples: left image = Distinctive glass entry /corner feature, steel weather protection element, decorative
wood paneling, and decorative tilework. Right image = Decorative door and decorative mosaic tilework.
Southcenter Design Manual adopted- attchmt 5 -28 -14
33 03/25/2014
Southcenter Design Manual
Detail examples: Left image = Steel and glass weather protection and large openable window, decorative lights, and
colorful mural. Right image = Distinctive large glass patterned curtain -wall, decorative masonry, and decorative
wood component.
Detail examples: Left image = Display windowsd'vided into a grid of multiple panes, custom weather protection,
decorative masonry, and decorative lighting. Right image (residential building) = Decorative weather protection
over the entry, decorative masonry, and decorative lights.
5outhcenter Design Manual adopted - attchmt 5 -2844
34 03/25/2014
Southcenter Design Manual
12. BUILDING MATERIALS AND COLORS
Intent
• Utilize durable, high quality exterior building materials that contribute to the overall appearance and
longevity of the building, as well as colors and textures that reflect the local setting and further
articulate the building design.
Design Criteria
A. Use of natural materials that reflect our Northwest setting such as stone, local woods like cedar
and fir, and functional materials like concrete, brick, and metal are encouraged.
1. Descriptive Definitions and usage recommendations:
a) Brick: Full size brick is preferable to thin veneer brick. When used, brick veneers should be
mortared to give the appearance of full -depth brick and detailed with wrap - around corner and
bullnose pieces.
b) Ceramic tile: Glazed and unglazed tile should be limited in use to a facade cladding or decorative
wall accent material. Simple color palettes and design motifs should be used.
c) Fiber - Cement or Cement`iitious Siding: An exterior siding product available in planks, panels and
shingles and composed of portland cement, ground sand, cellulose fiber and sometimes clay,
mixed with water and cured in an autoclave.
d) Fiber - reinforced plastics (FRP), cast glass fiber composites ( "fiberglass "): These materials are
often used in molded reproductions of carved wooden or cast metal architectural
ornamentation such as architectural columns, capitals and bases, cornices, and other trim, They
may be used if their appearance closely approximates the type of painted wood element they
are simulating, and are coordinated in color and composition with the selected architectural
style. They should only be used at locations above the reach of pedestrians.
e) Profile, Corrugated, and Other Sheet, Rolled and Extruded Metal Surfaces: Where used, sheet
metal should be detailed with adequate thickness to resist dents and impacts, and should have
trim elements to protect edges. Metal siding shall have features such as visible corner moldings
and trim and incorporate masonry, stone, or other durable permanent materials near the
ground level (first two feet above sidewalk or ground level). Metal siding shall be factory finished
with a matte, non - reflective surface.
Southcenter Design Manual adopted - attchmt 5 -28 -14
35 03/25/2014
Southcenter Design Manual
f) Stone (including river stone), stone veneers, cast stone, terra cotta, precast concrete, glass fiber
reinforced concrete (GFRC). Improperly simulated or contradictory finishes (Le. use of panelized
concrete to simulate a riverstone wall appearance with visible straight -line joints cutting across
individual stones) should not be used.
EIFS (Exterior Insulating and Finish Systems): Close attention should be paid to detail and trim
elements for a high quality installation. Very stylized or highly textured surfaces are strongly
discouraged. Joint patterns should be architecturally coordinated with overall facade
composition. These finishes should be sheltered from extreme weather by roof overhangs or
other methods and weather exposed horizontal surfaces should be avoided.
EIFS should not extend below two feet above the ground plane. Use concrete, masonry, or
other durable material for wall surfaces within two feet of grade to provide a durable surface
where damage is most likely.
g)
These two buildings employ EIFS as the predominate siding material, but employ masonry near the ground level
which provides greater durability and contributes to the character of the buildings.
h) Wood: Horizontal sidings such as clapboard and tongue -in- groove; vertical siding such as board
and batten; and other horizontal sidings such as smaller wood shingles may be suitable. The
larger, more rustic styles of shakes should not be used. Trim elements should be used for all
wood siding types. Timber detailing and exposed bracing may be appropriate. "T1 -11" plywood
panel siding is not allowed.
Southcenter Design Manual adopted-attchmt 5 -28 -14
36
03/25/2014
Southcenter Design Manual
1) Precast Concrete: The location and spacing of panel and expansion joints should be incorporated
into the facade composition. Castings should be shaped to form architectural profiles that create
bases, cornices, pilasters, panel frames, and other elements contributing to facade composition
and human scale. Cement type, mineral pigments, special aggregates and surface textures may
be used in precast concrete to achieve architectural texture and variety.
Poured -in -Place Concrete: Long surfaces of uninterrupted concrete walls should not be used.
The use of textured form liners, pigments, stains, and /or special aggregates should be used to
create visual interesting surfaces. At a minimum, the design of exposed concrete walls should
incorporate the location and spacing of formwork tie - holes, expansion joints and control joints
into the facade composition. The architectural treatment of poured concrete that is used as a
building architectural base should be extended to concrete used elsewhere in the project for
sitework material.
j)
k) Concrete Block: Incorporate a combination of textures to provide visual interest (such as split or
rock - facade units and /or contrasting colored units with plain smooth block can create distinctive
patterns). Decorative treatments such as alternating block courses of differing heights,
contrasting grout colors, alternating surface textures (e.g. precision face and split face) and/or
compositions of colored blocks should be used, along with matching cap and trim pieces. Plain
concrete block fire walls on the sides of a building that are visible to the public are discouraged.
2. Local and recycled building materials should be used whenever possible.
3. If the building massing and pattern of windows and doors is complex, a simple palette of wall
materials, textures and /or colors should be used. If the building volume and the pattern of wall
openings are simple, additional wall materials, textures and articulation may be utilized.
B. Use wall cladding materials appropriate to the architectural style and building type. Authentic
materials and methods of construction should be used to the degree possible.
1. Where simulated cladding materials (e.g. artificial stone to substitute for real stone, or painted
fiber reinforced plastics to substitute for painted wood) are used for reasons of economy, they
should be durable and closely match proportions, surface finishes, and colors of original materials.
2. Fiber - Cement or Cementitious Siding: Planks are an acceptable substitute for wood siding when
used in the formats described above under "Wood." To match the precedents of real wood siding
in the area the spacing of siding should not exceed 8 ".
Southcenter Design Manual adopted- attchmt 5 -28 -14
37 03/25/2014
Southcenter Design Manual
3. Profile and Other Sheet, Rolled and Extruded Metal: As wall cladding, these wall systems should be
used as a secondary or accent material. A high quality, durable, fade- resistant coating system or
paint such as Kynar, Tnemec, etc. is recommended.
4. Stucco or EIFS: Stucco and EIFS finishes are acceptable finishes for upper stories only at street
exposures on commercial buildings. They should not be used at storefronts. They may be used at
ground floor portions of rear or side service and parking exposures and in such cases should be
specified with high- density materials, with the ground floor street facade cladding materials
continuing to be used as a building base and accent material.
5. Wall Accent Materials; are recommended to add interest and variety, for example, at architectural
elements such as cornices and on portions of buildings or walls. Materials recommended for use as
accents include brick, wood, stone, Fiber Reinforced Plastic, ceramic tile as listed above, in keeping
with the architectural style of the building.
C. Color: Incorporate more than two colors and materials into each building's design. Mono-
chromatic schemes are discouraged. Color choices should include warm rich colors that reflect
and complement the woodlands, water and open sky of the region; weathered wood and
oxidized metal colors related to industrial and agricultural influences.
1. Primary building colors, used at building walls, freestanding site walls, and other primary building
elements, should be saturated colors to complement Tukwila's forested surroundings and often
overcast skies. Extremely bright colors should not be used as primary wall colors.
2. Secondary color should complement the primary building color, and may be a lighter shade than
the body color, or use more saturated hues. Secondary color can be used to give additional
emphasis to architectural features such as building bases or wainscots, columns, brackets, cornices,
capitals, and bands; or used as trim on doorframes, storefront elements, windows and window
frames, railing, shutters, ornament, fences, and similar features.
Southcenter Design Manual adopted- attchrnt 5 -28 -14
38 03/25/2014
Southcenter Design Manual
3. Accent colors may be more saturated in color, or brighter in tone, and used to highlight special
features such as doors, shutters, gates, ornament, or storefront elements. Bright colors should be
limited to retail establishments, and used sparingly at fabric awnings, banners, window frames, or
special architectural details. A restrained use of bright colors allows display windows and .
merchandise to catch the eye and stand out in the visual field.
4. Colors should be compatible with other buildings in the surrounding area. Colors of adjacent
buildings should be taken into consideration.
5. Fluorescent colors should not be used on building materials.
6. At attached residential units, primary and secondary building colors may contain variations in color
from unit to unit, to further distinguish the individual identity of each residence.
Southcenter Design Manual adopted - attchmt 5 -28 -14
39 03/25/2014
Southcenter Design Manual
13. WINDOWS
Intent
• To encourage large expanses of glass across facades to provide daylighting of internal spaces, visual
interest, and access to views while providing a visual connection between activities inside and
outside.
• To provide visual access and interest at the street level through the use of ground level windows.
• To design windows to be in keeping with the character and the architectural style of the building.
• To relate windows throughout a building's facades in design, operating type, proportions, and trim.
They should be used as architectural elements that add relief to the fagade and wall surface.
Design Criteria
A. Use windows as an element which helps to articulate the character of a facade and define an
architectural style.
1. Windows within solid walls (walls not designed as curtain wall systems) should not sit in the same
plane as the wall surface. They should be recessed at least 4 ", with the wall material turning the
corner at the window jambs, in order to emphasize the wall thickness.
2. Windows should have design and scale relative to the spaces behind them.
3. Window accessories such as window boxes for plants, fabric awnings, etc. should be considered for
additional articulation and interest, in coordination with the selected architectural style and
building use.
Southcenter Design Manual adopted- attchmt 5 -28 -14 40
03/25/2014
Southcenter Design Manual
B. Design window frames and sills to be prominent and substantial in order to enhance openings
and add additional relief.
. The size of elements should be proportional to the glass area framed, as where a larger window
may use commensurately wider framing members.
2. Upper story windows and parking structure "window" openings should be detailed with
architectural elements such as projecting "lug" sills, and/or lintels.
3. Ornamental framing and hardware provide utilitarian opportunity for craftsmanship and
decoration. This is especially important to avoid an insubstantial appearance common to aluminum
sliding windows; these should be accompanied by well- detailed frame and sill elements.
4. Windows designed as glass curtain wall systems (where they are not treated as a separate element
from the facade system) should be designed with projecting vertical and /or horizontal mullions, or
other modulating features.
5. "Lug sills" (protruding window sills) should not be formed of rigid foam or other substrates sprayed
with stucco or other wall finish material. They should instead be constructed with a permanent
material such as painted wood, painted FRP, metal, precast concrete, GFRC, terra cotta, or stone.
6. Where multi -pane windows are utilized, specify "true divided light" windows or sectional windows.
"Snap -in" muntins (i.e. detachable vertical or horizontal glass plane dividers or glass pane dividers
sandwiched between layers of glass) do not meet the design intent.
Southcenter Design Manual adopted - attchmt 5 -28 -14
41 03/25/2014
Southcenter Design Manual
Examples of multi -paned windows
Southcenter Design Manual adopted- attchmt 5 -28 -14
42 03/25/2014
Southcenter Design Manual
14. WEATHER PROTECTION
Intent
• To provide additional shelter at the edges of buildings and entrances from wind and rain through the
use of porticos, covered porches, and arcades.
• To improve the pedestrian experience by providing protection from inclement weather.
Design Criteria
A. Design buildings with non - residential ground floor uses to provide pedestrian weather
protection along adjacent street front sidewalks and open spaces using awnings, canopies, or
building overhangs such as porticos, covered porches and arcades.
1. See TMC 18.28.160(B)(3) for weather protection requirements for buildings where orientation to
streets or open space is required.
2. Design canopies or awnings with an overhead clearance between 8 to 12 feet.
3. Design weather protection as a permanent architectural element. Relate materials and details to
the building as a whole.
4. Continuous weather protection coverage in pedestrian oriented areas is desirable. Different
methods can be used to accommodate continuous coverage. For a sequence of storefronts or
windows, a sequence of discrete, overlapping awnings or canopies for each storefront or building
bay should be used, rather than one continuous run -on awning.
Southcenter Design Manual adopted- attchmt 5 -28 -14 43
03/25/2014
Southcenter Design Manual
5. Drainage should be designed so that the awning or canopy does not drip on pedestrians.
6. Awnings and canopies on multi -story buildings should be designed to accommodate Fire
Department ladder access requirements.
7. Where not in conflict with the Design Criteria, shading devices such as building/roof overhangs,
latticework and trellises should be incorporated primarily into south - facing facades and designed to
balance summer cooling and winter heating by maximizing solar gain during the winter and
minimizing solar gain during the summer.
8. Deep canopies on building faces subject to heavy shade either because of orientation (north facing)
or adjacent building form (blocking sunlight), should incorporate glazing into part of the canopy to
allow natural light to penetrate to storefronts and the sidewalk below.
r
B. Relate awning design to the other elements of the building facade
1. Colored fabric mounted awnings supported by a metal structural frame are recommended.
Awnings should be made of durable materials, avoiding the use of vinyl, plastic, and flimsy fabrics.
2. Awnings should not cover up intermediate piers, pilasters, or other vertical architectural elements.
3. Storefront awnings should not dominate or obscure the storefront or facade.
C. Design residential buildings to provide weather protection over primary building entries:
Southcenter Design Manual adopted - attchmt 5 -2844 44
03/25/2014
Southcenter Design Manual
1. Incorporate weather protection at least six feet deep across the width of shared /common entries.
2. Incorporate weather protection at least three feet deep across the width of individual external unit
entries.
Residential weather protection examples.
Southcenter Design Manual adopted- attchmt 5-28-14 45 03/25/2014
Southcenter Design Manual
15. BLANK WALLS
Intent
• To encourage the design of building facades which incorporate interesting architectural details that
add variety to the facade, animate the street presence, and are attractive at a pedestrian scale.
• To enhance the pedestrian environment by avoiding large blank walls visible from public areas and
adjacent properties.
Design Criteria
A. Consider all facades including side and rear facades as visible (unless facing "blind" onto an
adjacent party wall) and treat with an architectural facade composition similar to that on the
building's front.
1. Blank walls, as defined below, are not permitted facing streets, sidewalks, open spaces, or
pedestrian pathways because they do not provide visual interest or human scale.
2. Use compatible materials on all four sides of the building.
3. Use one of more of the following treatments to address blank walls:
a) The pattern of openings and windows should be carried across windowless walls to add visual
interest and avoid blank surfaces.
b) Install a vertical trellis in front of the wall with climbing vines or plant materials.
c) Provide a planting bed at least 5 feet wide or a raised planter bed at least 2 feet wide by 3 feet
long in front of the wall, and establish plant materials that will obscure or screen 60 percent of
the wall's surface within 3 years.
d) Install a display window per 18.28.200(C).
e) Provide artwork (a mosaic, mural, sculptural relief, etc.) over a significant portion of the blank
wall surface and illuminate it for nighttime visibility.
Southcenter Design Manual adapted- attchmt 5 -28 -14 46
03/25/2014
Southcertter Design Manual
f) Incorporate changes of materials and/or texture in the wall and accent it with architectural
details.
Blank wall definition
A wall (including building facades and retaining walls) is considered a blank wall if:
• A ground floor wall or portion of a ground floor wall over 6 feet in height and a horizontal length
greater than 15 feet and does not include a transparent window or door; or
• Any portion of a ground floor wall having a surface area of 400 square feet or greater and does not
include a transparent window or door.
greater than
400 ft2
BLANK WALL I
1 greater than
15'-.
Trell.s with vanes or
other pants
Artwork
Landscap ∎ng
Blank wall definition and treatment example.
5outhcenter Design Manual adopted - attchmt 5 -28 -14
47 03/25/2014
Southcenter Design Manual
16. PARKING STRUCTURES
Intent
• To reduce the visual impact of parking structures.
• To improve the street level presence for parking structures adjacent to streets.
• To integrate the design of parking structures with surrounding development.
Design Criteria
A. Design parking structures which are part of a new development to be architecturally consistent
with exterior elements of the primary structure, including roof lines, facade design and finish
materials.
1. Building massing should conform to the facade articulation and major vertical modulation
provisions of Section 9 (Building Massing). Such structures should be simple but well- articulated in
length and height for pedestrian scale and avoid excessive emphasis on Tong -span openings.
Vertical elements — columns, pilasters, etc. should be used to better relate parking structures to
surrounding retail, office and residential structures of similar height.
2. Special massing should be used to identify main vehicular entrances and pedestrian vertical
circulation.
3. Weather protection such as canopies and other facade- attached elements may serve as ways to
incorporate expressive structural elements typical to Pacific Northwest design character.
4. Facade openings generally cover a high percentage of the facade area. Columns, decorative
screening, and other intermediate members should be used to break down the scale of parking.
Southcenter Design Manual adopted- attchmt 5 -28 -14 48
03/25/2014
Southcenter Design Manual
structure facades.
5. Design security grilles for parking structures to be decorative and architecturally consistent with
the overall design. Chain Zink fencing is not permitted as a window treatment.
6. Due to their highly visible location, light poles and fixtures at roof parking decks should be specified
or designed as decorative fixtures, architecturally coordinated with the style of the building.
7. Landscaped trellis' in conjunction with above design/articulation techniques are encouraged as an
effective way to soften the fagade and add visual interest.
B. Design ground floors of parking structures that front on Tukwila Pond or public streets in the
TOD and Pond Districts to accommodate future office, retail or residential uses.
Southcenter Design Manual adopted- attchmt 5 -2844 49