Loading...
HomeMy WebLinkAboutPermit 0662-M - HOMEWOOD SUITES0662-M 91-165M HOMEWOOD SUITES 6945 SOUTHCENTER BOULEVARD POOL AND SPA SUITS .t ::.•::<:>::; >:: :: :;: ... :::::�:� >� >< > :OQQ��:COMPi<:IANG `:;:: >:: >� > ;. :<:::�;::<; >::: >:; _ _ _::. UMC EDITION (YEAR : 1988 FIRE PROTECTION: Sprinklers Detectors x N/A • CONDITIONS (other than noted on or attached to permit /plans): ZIP: 71457 CONTRACTOR: - -te APPROVED FOR ISSUANCE BY: BUILDING A ± &i'L.2 44„ OFFICIAL DATE: //- -` ?f P.O. Box 3663, Bellevue, WA "" I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating co struction or thecp-rformance of work. I am authorized to sign for and obtain this mechanical permit. SIGNATUR WA. ST, CONTRACTOR' DATE: r } `"1 ----, PRINT NAME: N(1(1 I S 1 e.1 SQ,(, COMPAN 1c qJ q * (\-) ()► F- L PROPERTY OWNER; Dimension Development Co. Inc. PHONE: 318- 352 -8238 ADDRESS: 200 Front Street, Natichitoches, LA ZIP: 71457 CONTRACTOR: Towne & Country Pools, Inc. (PHONE: 488 -1429 ADDRESS: P.O. Box 3663, Bellevue, WA (ZIP: •98009 WA. ST, CONTRACTOR' LICENSE NO. TOWNECP103LR EXPIRATION DATE: q -3� —g CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 MECHANICAL PERMIT NO. c)l0(.0 lrn DATE ISSUED: \�^ f - 49Q 6945 Southcenter B1 MECHANt.FAL PERMIT (POST WITH PLANS IN A CONSPICUOUS LOCATION) BSS is Permit Fee<: <'> .i_ . hw_O iock Fe Plan Check No.: ":::AMOUNT 91 -165 —M SUITE NO. :RECEIPT:# » <DATE PROJECT NAME/TENANT Homewood Suites VALUE OF WORK: $ 2,500.00 TYPE OF WORK; (j New /Addition (D Modifications ( Repair ( ) Other: DESCRIPTION OF WORK: Install heater for pool, and spa. SITE ADDRESS: • •' • a le .10 5 I x IA P. DATE REQUIRED INSPECTIONS PHONE NO. APPROVED 1 - Rough -in /Vents /Ducts 431 -3670 2 - Fire Final 3 - Planning Final 4 - 5 - Mechanical Final 575 -4407 431 -3680 431 -3670 DATE(S) INSPECTOR CORRECTION NOTICE ISSUED OTHER AGENCIES: Plumbing /Gas Piping - King County Health Department (296 -4732) Electrical = Washington State Department of Labor and Industries (277 -7272) This permit shall become null and void if. the work is not commenced within 180 days from the date o issuance, or if the Work is suspended or abandoned for a period of 180 days from the last Inspection. PERMIT NO. CONTACTED Le 1 6?icr,-) vS Q. DATE READY DATE NOTIFIED II n B 1.— v l ) (init.) PERMIT EXPIRES 2nd NOTIFICATION L. --E - BY: I oL &Q- a I mai2..finit.) --oee AMOUNT OWING 3RD NOTIFICATION 0 BY: ,., Q a n112 0 Q. (init.) .IJ � • �� MECHANICS" PERMIT APPLICATION TRACKING PLAN CHECK NUMBER t o m INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". PARTM BUILDING - initial review O FIRE O PLANNING O OTHER BUILDING - final rAviAw REVIEW COMPLETED PROJECT NAME SITE ADDRESS cm q) I( ( ROUTED INIT: INIT: Fib INIT: tkcmczwroc S 6+-2.3 SUITE NO. (pq L.5 Soukhc,pr r 13) ... .:.:..::...::..: UIREME C O M MENT CONSULTANT: Date Sent - Date Approved - ZONING: FIRE PROTECTION: S rinklers -] Detectors ( ) N/A FIRE DEPT. LETTER DATED: SCREENING REQUIRED? nYes n No REFERENCE FILE NOS.: UMC EDITION (year): INSPECTOR: IBAR/LAND USE CONDITIONS? ( )Yes O 08/17/90 PROPERTY OWNER .c'x _) 27 J (CD , G___ RCPT: #: : PH0N Ea? Zs'2_ � 3 ADDRESS "-, '-- -- �� �� •�-- Ci,i`C I I �S � � c1 ZIFn I 45r-- CONTRACTOR n � / , � ) P HONE • d PLAN CHECK'':FEE ADDRESS (.3 )‹ Y- 1 t.�� ZK + WA. ST. CONTRACTOR'S LICENSE # Tit . 3 L EXP. DATF� 1 -C12 ::: DESCRIPTION ;:AMOUNT:::: RCPT: #: : ::: BASIC PERMIT .FEE : : $15.00 UNITS :FEE 5:07 PLAN CHECK'':FEE THER TOTAL' a i• CS CITY OF TUKWILA Department of Community Development - Building 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK NUMBER APPLICATION MUST BE FILLED OUT COMPLETELY DATE APPLICATION ACCEPTED MECHAI.CAL PERMIT APPLICATION Division Mechanical Fee Worksheet must also be filled out and attached to this application. FEES (for staff use only) r igi AS DRESS >(� V1(" t' ; \v �, k� ►1 + P ROJECT NAME/TENANT Owe (...) 06 TYPE OF WORK: o ew /Addition 0 Modifications 0 Repair 0 Other: VALUE OF CONSTRUCTION - $ 1$0c - Tota\ 41 a Sat VT- O fl 9 D SCRIBE WORK T. -B DONE: RATING/SIZE > >< < >`'tVUh116ER OF ><tlf�tiTS! >> BUILDING USE (office, warehouse, etc.) NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE? N WILL THERE BUILDING? E 0 Yes IF YES, EXPLAIN: TORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE No 0 Yes IF YES, EXPLAIN: BUILDING OWNER SIGNATUR OR AUTHORIZED AGENT CONTACT PERSON E; READ;;AND EXAMINED;; THIS : :APPLICATION t�AUTHORI ED Q APPLY FOR ;THIS PERMIT PRINT NAMEp n (1,.% S ADDRESS PHONE APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. A completed "Mechanical Permit Fee Worksheet" must accompany this permit application. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. if you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 431 -3670. DATE APPLICATION 4P14b 06/18/90 DESCRIPTION UNIT COST NO OF UNITS X TOTAL COST BASIC FEE $15.00 SUPPLEMENT PERMIT FEE $4.50 1 Installation or relocation of each forced -air gravity -type furnace or burner, including ducts and vents attached to such appliance, up to and including 100,000 Btu /h. $9.00 X 2 Installation or relocation of each forced -air or gravity -type furnace or burner, including ducts and vents attached to such appliance over 100,000 Btu /h. $11.00 X 3 Installation or relocation of each floor furnace, including vent. $9.00 x 4 Installation or relocation of each suspended heater, recessed wall heater or floor - mounted unit heater. $g,00 X 5 Installation, relocation or replacement of each appliance vent installed and not included in an appliance permit. $4.50 x 6 Repair of, alteration of, or addition to each heating appliance, refrigeration unit, cooling unit, absorption unit, or each heating, cooling, absorption, or evaporative cooling system, including installation of controls regulated by this code. $9.00 X 7 Installation or relocation of each boiler or compressor to and including three horsepower, or each absorption system to and including 100,000 Btu /h. $9.00 x 8 Installation or relocation of each boiler or compressor over three horsepower to and including 15 horsepower, or each absorption system over 100,000 Btu /h and including 500,000 Btu /h. $16.50 X 9 Installation or relocation of each boiler or compressor over 15 horsepower to and including 30 horsepower, or each absorption system over 500,000 Btu /h to and including 1,750,000 Btu /h. $22.50 X 10 Installation or relocation of each boiler or compressor over 30 horsepower to and including 50 horsepower, or for each absorption system over 1,000,000 Btu /h to and including 1,750,000 Btu /h. $33.50 x 11 Installation or relocation of each boiler or refrigeration compressor over 50 horsepower, or each absorption system over 1,750,000 Btu /h. $56.00 X 12 Each air - handling unit to and including 10,000 cubic feet per minute, including ducts attached thereto. (NOTE: This fee shall not apply to an air - handling unit which is a portion of a factory- assembled appliance, cooling unit, evaporative cooler or absorption unit for which a permit is required elsewhere in this code.) $6.50 X 13 Each air - handling unit over 10,000 cfm. $11.00 X 14 Each evaporative cooler other than a portable type. $6.50 X 15 Each ventilation fan connected to a single duct. $4.50 X 16 Each ventilation system which is not a portion of any heating or air - conditioning system authorized by a permit. $6.50 X 17 Installation of each hood which is served by mechanical exhaust, including the ducts for such hood. $6.50 X 18 Installation or relocation of each commercial or industrial -type incinerator. $11.00 X 19 Installation or relocation of each commercial or industrial -type incinerator. $45.00 X 20 Each appliance or piece of equipment regulated by the code but not classed in other appliance categories, or for which no other fee is listed in this code. $6.50 - 7 / x A5 06118/90 SUBTOTAL Qt,0% PLAN CHECK FEE (25% of subtotal) '7 • oo GRAND TOTAL $ 35.0Z MECHAN[: ;AL PERMIT FEE WORKSHEET CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 THIS WORKSHEET MUST ACCOMPANY YOUR MECHANICAL PERMIT APPLICATION. INSTRUCTIONS C omplete the worksh Indicating'the number of units being installed:in each category At time of :ubmrttal, st will calculate the fees. CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD. TUKIVILA. WASHINGTON 98188 Plan Check #91- 165 -M: Homewood Suites 6945 Southcenter Bl PHONE H (206) 433.1800 Gary L. VanDrrsen, Mayor THE FOLLOWING COMMENTS APPLY TO AND BECOME PART OF THE APPROVED DY PLANS UNDER TUKWILA MECHANICAL PERMIT NUMBER Q(Q k9 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296 - 4722). 3. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (277 - 7272). 4. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 5. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 6. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1991 Edition), and Washington State Regulations for Barrier Free Facility (1989 Edition). 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. PROJECT: `AI 1r2t - 21rsfya ' PERMIT NO. 06 Cot. -- Y)I SITE ADDRESS: DATE CALLED: DATE WANTED: _ .m. .. TYPE OF INSPECTION: FT IJ .-- SPECIAL INSTRUCTIONS: REQUESTER: PHONE NO.: INSPECTION RESULTS /COMMENDS: d -fo INSPECTOR: L _ - DATE: Z-" 2-• --9 CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 INSPECTION RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 RECEIVED CITY OF TI IKWILA SEP 17 1991 PERMIT CENTER I understand th subject to errors a plans does not auth adopted code or ordi . n tractor'sopy of approved Permit No. O ck approvals are s and approval of violation of any Receipt of con - is acknowledged. FLOW METER . EST SET ;11.ENGTH • I.:WIDTH ; (AVG. ) ' :;,•!pARx METER DEPTH.. . ...rm." I HERMOHETER S I G,HT . . • 46.a/g/ * DESIGN DATA • L._ iLIFE RING LIFE HOOK FILL S POUT :;44 DEPTH !1,,S,URFACE• AREA (SQ: rr, REA ,LESS... THAN 5'.. DEEP (GALLONS) FILTER AREA (SQ FT ) : - FILTER CAPACITY 1GP GPM FOR OR. TURNOVER eet . TD H RECEIVED' CITY ( TI IKWILPf 'ITEM px.traR' . •i • EgOb PUMP STRAINERQ HEATER DIVING BOARD' GRAB RAIL . STEPS LIGHT MAIN DRAIN FRAME. & GRATE • VACUUM CLEANER 'CHLORINATOR •• NO . REQD . r)EL NO DESCRIPTION :/ 3pN-- • r. ••' rni r/ SiAS 47 77i /V•r -9 H. . ..2.3 0 . c . . . 94,:ar . . 6 " 6"0".ytisrK..E3T * .Lr:5:472cea&pz. _ ..... =. /Zei s 'ifeAF RAf<d:F=4..:2E3RO. 77.77257: . 'WHY r• • • • • • ••• • • • ••••••• • • • •••••••••■:••••••••••••••••■• • •••• • ••• • •••••■•• .••••7••■•••• ....... = NA-evirc., 1N.\\IgiW ' s 5 . •••••• • • ••••• ••••••• • •• -•••••••- ••• • • ry C.(k) • ••• -• - .... ....... ••• ••••••••■••" - •• -- . 'NOTE : ' AI-1.; .P I PING X0 _ 2 . BE. V . C... SCHEDUL.E...,40 .. ...... • ----- .... ..... • - .....- -- - - --,------kka:•-•" -••--- - • - • • ., . . . ' ...41.1,4............•• ... • . • , •,,1„ 0•11 • •4 • 4 t• • • . ••••• •,..: • • o • •••• •• •• • • ••• , •,. • • • 4 • 01 • 0.0 • •• 1 .0 0. • 4..4" . • . 4 ..... ,• . ....... .... • o• 4 . "cm .........• eote.••• .6.10..4. ••••• • as• .004 0,0 • ••••••••• • • 9 • .4 • • • • • •••• , . • 0 01 • 0. 0 0 • 0 • 0.00 • • • lel% 000. •••:••±: 060:01111 •••• slew "10 • • ' ‘ • ••••••• 0 • •00 404 ••• 404.0 •••■•••••••• • ...DO ••••• • 1••••••••••••• ••••••••• • •4000 •• • • • • .I, 00 4 • I .4 • • III 0 09 0 , ' t 0 f I/01 0 • 6 . •14, I. • • ;:........ ,•." 7. i • VA .?„,•:, ....!... • • ' • • rl• 11••• .1. ••• ,••." v • • • ' • • •• • .• 'ITEM FILTER • PUMP STRAINERQ HEATER DIVING BOARD' GRAB RAIL STEPS LIGHT MAIN DRAIN . ..* : FRAME & GRATE WALL INLETS FLOOR INLETS SKIMMER • FILL S POUT LIFE RING LIFE HOOK VACUUM CLEANER CHLORINATOR FLOW METER TEST SET • CUP. ANCHORS.-- FEE RMOMETER S I G HT :1G LASS:777. ' :4 NOTE ALL PIPING TO. BE...2. V. C.. SCHEDULE ..40 • ..• • •••.• . DESIGN DATA LENGTH WIDTH (AVG. PERIMETER . MIN. DEPTH • MtX . DEPTH SURFACE. AREA (SQ. FT . ) NO . REQD. amt.. NO 1 -0 /S47.c ---= • " • AREA LESS THAN 5 DEEP ' CAPACITY (GALLONS ) ' FILTER AREA (SQ . FT ) GPM FOR6 HR. TURNOVER - 5 - P-Sol ........ F- 3•Q tviefet moNr ntra ••:.:• 72 ' 120 3 -26 :•fla: , MAX.. FILTER CAPACITY • DESCRIPTION' /9M(1 - eik 61 1.64,y4f/Ag ) 6 . " -"- - vy115 ................. cYcoti A rj,TO 57■ r F wjA 7'"A =37 . . E321i3 • - W7e 6:I - fee; - 7ELe sct=q L4AF R,We':Fi-jnP(..-:1E3RaS! ' 7.67 4 e.- 1 ,2 • ' WH I T:e•• cl iicti :isxia • ••• " ::" 7.77.7.7.7 777.777 '7' • :' PIZ 'AYe..R6fid eArr /4. • 5 7 ev4 s s . 5 re... ...M. •, • • 1. •• •... ••.• • • • • • • MMIN•101 . . . . . ..... • .•, • •, •-... • • - • -• ..• ••,..-• • .. RECEIVED PERFORMANCE CHART CITtitQf TUKWILA SEP 13 9 19b1 P •ERMITCEA'PE 60 40 f"/4-7 4,2/firis — • •.1.• - V.3.710 114001 . I " • .• 1 ••• IL 4 WI •••:1::••••• 11/1./V1 • (0 p I - 4.01155.555181551•1151=1.30=5515110514 • • W.)011 _4_ • 7 1 )20 14 Olc's / , 71. ••• . • ALL0/111 1.5/1 UlDlIJ Ftc..7 • %No • ,,, ; I i• • 1 TELEDYNE LAARS POOL AND SPA HEATERS T he full enjoyment of your pool or spa ultimately depends on how comfortable it is — and that's where Teledyne Laars excels — by making your warm water recreation more pleasant and an integral part of your leisure time relaxation. The Series One pool and spa heaters are designed with ease of operation, durability, and your safety in mind. Another very significant benefit is energy efficiency: a heater with high energy efficiency will, quite simply, result in lower monthly fuel costs foryou. And Series One is unsurpassed in energy efficiency — models are rated at 80 %, as affirmed by laboratory testing: Series One has the highest average energy efficiency of any heaters on the market today. They are also design certified by the American Gas Association Laboratories to ANSI standard Z2I.56. You are assured of lower operating costs and a higher level of comfort. So it's no surprise that Teledyne Laars is the first choice for gas pool and spa heaters among homeowners and builders today. With forty years experience in water heating appliances, Teledyne Laars designs and builds tough, reliable heaters utilizing state- of -the- art technology — and all pool and spa products are backed by a two- year /five -year double protection warranty which is unsurpassed by any other heater. The Series One heater is available in a variety of models from 125,000 to 400,000 BTUH with a choice of natural or propane gas. Many features of the Series One are designed for ease of use by the homeowner: The control module is up front, at a convenient level, and recessed and tilted for easy reading. An ON /OFF switch and a temperature dial make water tempera- ture adjustment easy. The gas controls are also in front for ready access for service, but placed behind the latched panel door for safety. Plus bronze headers (optional) are available on all models. Convenience, safety and energy efficiency, along with other features, are built into your Series One heater. Stainless Steel Burners deliver even flame dis- tribution and years of trouble -free operation. The Quality and ReliabilityYou Expect fiomi1edyne Laar The First Name in Pool and SpaHeating. Two- Year/Five -Year Double Protection warranty assures you that Series One heaters are quality built to give you the reliable service you expect from Teledyne Laars. The controls, copper heat exchanger tubes and firebox panels are warranted against defects in materials and workmanship for two years from date of purchase. All other parts are warranted against defects in materials and workmanship for five years from date of purchase. There is no better heater warranty on the market today. The Series One is also backed by the largest nationwide war- ranty service and parts network. IMMMMNONggilg ummiumingi Compare these quality and energy saving features, and you'll know why Teledyne Laars is the first choice among more pool and spa owners and pool professionals than any other heater Ask for the Series One and be assured of value in your new heater. Exclusive Finned Copper Heat Exchanger affords m dent heat transfer The be you is greater energy effic with lower operating cost! Temp-Lok Control feature you to set the maximum t ture desired and lock it in It remains at that level un choose to reset it. Concen temperature adjustment unnecessary heat -up is vi eliminated. r^ nifty and ReliabilityYou Expect from14edyne Laars... stNameinPool and SpaHeating. -lent of your pool or spa ultimately depends on how comfortable it is — and that's ne Laars excels — by making your warm water recreation more pleasant and art of your leisure time relaxation. es One pool and spa heaters are designed with ease of operation, d your safety in mind. Another very significant benefit is energy high energy efficiency will, quite simply, result in lower monthly fuel One is unsurpassed in energy efficiency — models are rated at 80 %, as esting; Series One has the highest average energy efficiency of any oday. They are also design certified by the American Gas Association 3ndard Z21.56. You are assured of lower operating costs and a higher hat Teledyne Laars is the first choice for gas pool and spa heaters d builders today. With forty years experience in water heating 3rs designs and builds tough, reliable heaters utilizing state-of-the- pool and spa products are backed by a two- year/five -year double ch is unsurpassed by any other heater. 3ter is available in a variety of 100,000 BTUH with a choice as. ie Series One are designed omeowner: The control convenient level, and !asy reading. An ON /OFF e dial make water tempera- re also in front for ready laced behind the latched s bronze headers (optional) leis. y and energy efficiency. !s, are built into your Stainless Steel Burners deliver even flame dis- tribution and years of trouble -free operation. Two- YeadFive Year Double Protection Warranty assures you that Series One heaters are quality built to give you the reliable service you expect from Teledyne Laars. The controls, copper heat exchanger tubes and firebox panels are warranted against defects in materials and workmanship for two years from date of purchase. All other parts are warranted against defects in materials and workmanship for five years from date of purchase. There is no better heater warranty on the market today. The Series One is also backed by the largest nationwide war- ranty service and parts network. ina Kul as no Is si Compare these quality and energy saving features, and you'll know why Teledyne Laars is the first choice among more pool and spa owners and pool professionals than any other heater. Ask for the Series One and be assured of value in your new heater. Exclusive Finned Copper Tube Heat Exchanger affords more effi- cient heat transfer The benefit to you is greater energy efficiency with lower operating costs. Temp -Lok Control feature allows you to set the maximum tempera- ture desired and lock it in place. It remains at that level until you choose to reset it. Concern about temperature adjustment or unnecessary heat -up is virtually eliminated. o 'How To Choose A Series One Hea For Your Pool Using the sizing chart below to choose the correct size heater, first determine the difference between the desired pool temperature and the average air temperature during the coldest month you will be using your pool (referred to in the Heating Table as "Temperature Difference"). Second, calculate the surface area of the pool in square feet (length times width). Third, refer to the heating table below Listed are the maximum pool surface areas for each heater model with typical temperature differences Make the appropriate selection. Sizing Chart For Pool Heater Model No. 125 175 250 325 400 Temp. Dill. Maximum Pool Surface Area (Sq. FL) 15 °F 667 889 933 1244 1333 1778 1733 2311 2133 2844 20 °F 500 667 700 933 1000 1333 1300 1733 1600 2133 25 °F 400 533 560 747 800 1067 1040 1387 1280 1707 30 °F 333 444 467 622 667 889 867 1156 1067 1422 35 °F 286 381 400 533 571 762 743 990 914 1219 I. Sizing Chart is based on 3 -1/2 mph average wind and average pool depth of 5.5 feet. Shading on chart Indicates sizing at 0 (zero) mph wind. 2 All Series One Models ale design certified by the American Gas Associa- tion as gas -fired swimming pool, spa and hot tub heaters for natural gas and propane outdoor and indoor Installations. All models constructed for 75 psi working pressure. 3. Reduce input ratings by 4% for each 1000 feet above sea level. 4. The Series One EPG is available with pilot light only It is approved for sale in all states and Canada except where electronic ignition has been mandated by law. Specify the Series One Electronic In those states or when the advantages of electronic ignition are desired. 5. 'Ibledyne Laars maintains a policy of continuous improvement and therefore reserves the right to change specifications without notice. Specifications Type and IW) (SI Stack (V) Shipping Model No. Width Outdoor Indoor Vent Weight EPG -125 15 13 16 -9/16 5 215 175,000 EPG -175 18 13 -9/16 23 -1/2 6 240 250000 EPG -250 22 -1/2 18 -5/8 24 -3/4 7 270 EPG -325 26 -3/4 19-3/16 25 -7/8 8 310 EPG -400 31 -3/4 22-5/8 26 -7/8 9 345 BTU H Input T 13.I/8' Lj Outdoor 39-1/4 Vent Cap /Stack V 13.1 /B L Vent Cap & Indoor le LAARS Teledyne Laars 6000 Condor Drive, Moorpark, CA 93021 (805) 529-2000 Oakville, Ontario, Canada L6K 2H4 / (416) 844 -8233 Sizing Chart For Spa Heater How To Choose A ges One Heater For Your Spa To determine which size heater to specify, first identify the number of gallons your spa holds. Decide the heat -up time which is most consistent with your lifestyle, and then note on the chart below the Series One model necessary to achieve that. The chart indicates the approximate time required to raise spa temperature 30 ° F. For energy conservation and lowest heating cost, refer to Series One operating instructions or Teledyne Laars "Facts About Spas and How to Heat Them" Note there is a significant difference in heating time for the various size heaters. For example, to raise the temperature from 70 °F to 100 °F a 125,000 BTUH input heater on a 600 gallon spa will take approximately I hour and 30 minutes (depending on additional factors such as wind, spa insulation, etc.). With a 400,000 BTUH heater, heating to 100 °F would be accomplished in about 28 minutes. By comparison, a 6kW electric heater would require about 7 hours and 19 minutes, and a 1.5kW electric heater would heat a 600 gallon spa in 29 hours and 15 minutes. Model No. 125 175 250 325 400 Spa Size (Gal.) Time to Heat Spa 30 ° F' (Minutes) 200 30 21 15 12 300 400 28-I/2" 500 600 700 800 900 1000 45 32 23 60 43 30 75 54 38 90 64 45 105 75 53 120 86 60 135 150 Convertible Indoor /Outdoor 17 23 29 35 9 14 19 23 28 40 33 46 37 96 68 52 42 107 75 58 47 SEP 1 7 1991'3V - ° ;\ 1 '`PERMITC $TER ��O'4 © Teledyne a +�+11 `D` Litho In U.S.A. Teled cum y rs.8803 Document #3072c CITY OF TUKWILA 6200 SOUTHCE'NTER BOULEVARD, TUKIVILA, WASHINGTON 98188 September 12, 1991 Dennis Nielsen Towne & Country Pools Inc. P.O. Box 3663 Bellevue, WA 98009 RE: Homewood Suites pool and spa heater Plan check number 91 -165M Dear Mr. Neilsen: After an initial review of submitted information, it has been determined that additional required information be submitted to complete the plan review. Please address the following comments. 1. Provide site plan and building layout plan that will indicate location of the proposed heater. 2. Provide manufactures specification of proposed 110,000 BTU gas heater. 1To confirm you have received these comments, contact this office . and /or submit revisions within ten working days. Feel free to call me if there are any questions, 8:30 a.m. to 4:30 p.m. at 431 -3670. Sincerely, uz Ken Nelsen Plans Examiner PHONE II (206)433.1800 Gary L. VanDusea, Mayor