HomeMy WebLinkAboutPermit M92-0022 - METRO - SOUTH BASE REPAIR FACILITYM92-0022 METRO
12200 EAST MARGINAL WAY SOUTH
rnE170
•::::::;:;::::::imiii „..: ::::::::::::::::•i:::::::::::::o:::::::::::::::::::::::::::::::::4:::::.!:0:fficoogiiii0044p4lAncei:::::::;.!:::::::0:0:ii:::::::::•;:ii:;:i:::;:ag:;iiiM::::i;:::::::::::::::oii:ii::::::::::;::::$::::::::::::::::::::::::::::::ffil:::::::::;:::i01:::::;:::MI:Ii;::::
SITE ADDRESS: 12200 E Marginal Wy S SUITE NO.
liMO EDITION (YEAR ' 1988
FIRE PROTECTION: USprinklers flDetectors (X N/A
DESCRIPTION OF WORK: Install dust collector machine in bead blast room.
CONDITIQI4adother than noted on or attached to permit/plans):
821 Second Avenue, Seattle, WA
IZIP:
, ,
APPROVED FOR .j ye
ISSUANCE BY: / ii i / itAr.i.o.
BUILDING
OFFICIAL
,.,
DATE: /.. d _.9*--XZ ,
!PHONE:
V
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions
of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of
this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating co a • the performance of work. I am authorized to sign for and obtain this mechanical permit.
SIGN UR -: ---e-4-e------‘-ri/2 .,....- t..e____.)
ADDRESS;
•
DATE:
COMPANY: i-/X, Z eit t fLo. - 1, - , AZ
PRINT NAME: i' ' ; ' 4 i - 2 I J.47, Z.Zer...e.„ e
Ai::::::::::il.i:::]:::i
SITE ADDRESS: 12200 E Marginal Wy S SUITE NO.
PROJECT NAME/TENANT: Metro L vA1UE OF WORK: $ 11,500.00
TYPE OF WOR New/Addition (x) Modifications Repair Other:
DESCRIPTION OF WORK: Install dust collector machine in bead blast room.
ADDRESS:
PROPERTY OWNER*
Metro
PHONE:
684
ADDRESS:
821 Second Avenue, Seattle, WA
IZIP:
98104
CONTRACTOR;
Miller Sheetmetal Inc.
!PHONE:
479-1737
ADDRESS;
112 Shore Drive, Bremerton, WA
ZIP:
98310
WA. ST. CONTRACTOR'S LICENSE NO. MILLESI153MT
'EXPIRATION DATE:
8-28n92_,
. „
CITY OF TUKWILA
Department of Community Development - Building
6300 Southcenter Boulevard, Tukwila WA 98188
(206) 431-3670
MECHANICAL
PERMIT NO. e lnq Q— OD Da
DATE ISSUED:
MECHANICAL PERMIT -
(POST WITH PLANS (N A CONSPICUOUS LOCATION)
Division
FEES
Basic ......................................................
Unit Fee
.ELp_.Oheck Fee
TOTAL
RECEIP:711:4
:?tiAT:E1:11
•
•
Plan Check No.:
M92-0022
REQUIRED INSPECTIONS
X 1 • Rough-in/Vents/Ducts
2- Fire Final
3 - Planning Final
4 -
X 5 - Mechanical Final
MNSPECTIONligOORONCOitil0/90.tkideiitii00.
DATE
APPROVED
PHONE NO.
431-3670
575-4407
431-3680
431-3670
DATE(S)
INSPECTOR CORRECTION NOTICE ISSUED
OTHER AGENCIES: Plumbing/Gas Piping - King County Health Department (296-4732)
Electrical - Washington State Department of Labor and Industries
This permit shall become null and void if the work is not commenced within 180 days from tlie date of
issuance, or if the work is suspended or abandoned for a period of • 18 da from the last ins .
PERMIT NO.
CONTACTED
DATE NOTIFIED
Pa&
(-53—
B Y
DATE READY
PERMIT EXPIRES
2nd NOTIFICATION
BY:
(snit.)
AMOUNT OWING
Q t e : Cf Z
Q
3RD NOTIFICATION
BY:
(snit.)
PLAN CHECK
NUMBER
INSTRUCTIONS TO STAFF
• Contacts with applicants or requests for information should be summarized in writing by staff so that
any time the status of the project may be ascertained.
• Plan corrections shall be completed and approved prior to sending on to the next department.
• Any conditions or requirements for the permit shall be noted on the plans or summarized concisely
in the form of a formal letter or memo, which will be attached to the permit.
• Please fill out your section of the tracking chart completely. Where information requested is not
applicable, so note by using "N /A ".
DEPARTMENTAL REVIEW
"X" in box indicates which departments need to review the project.
..........................
BUILDING -
initial review
O FIRE
O PLANNING
O OTHER
'BUILDING -
final rAViAw
`Zcl
REVIEW COMPLETED
PROJECT NAME
Y Yn -Q
SITE ADDRESS
PR:0
1 � 2c ` 2
ROUTED)
INIT:
INIT:
INIT:
7 ert
INIT: t_
MECHANICA. PERMIT
APPLICATION TRACKING
SUITE NO.
1 a aao Yn.c r3i r o \ u��
CONSULTANT:
FIRE DEPT. LETTER DATED:
ZONING:
SCREENING REQUIRED? nYes n No
REFERENCE FILE NOS.:
UMC EDITION (year):
R EQUIREMENTS
Date Sent
Date Approved
FIRE PROTECTION: ( ) Sprinklers ( ]Detectors (1 N/A
INSPECTOR:
OAR/LAND USE CONDITIONS? (Yes No
OS/17/90
SITE ADDRESS SUITE #
Q V 00 E, M Ihe i/t/A L uiti
VALUE OF CONSTRUCTION - $
1 P _5--UO
PROJECT NAME/TENANT
,greed e6 ee6 Rooyn / -� /, L #) c/ l/ CA f/ a- '4.,, Or?--7' n --
TYPE OF WORK: 0 New /Addition AS Modifications 0 Repair 0 Other:
DESCRIBE
/ - WORK TO BE DONE: /
cY
, •5`'G� e7/4 7"Cl. 6114 C�0, / 5 c f ' e n r� e-ei -' ( C. / !t elf e• -7 P L cc -)-1.0, •
Z : : ><: ::: > > : :' ' : > > :: :: a.;:] : »' : :::: <: ><;NUMBER<OF UN T5: : : :: :<!i:< : > :;>
:>:::;.> �;:::::> : TYPiw: �::: �;°.; �::°::: >: >. : >� : �::: >•:<:� << ::: TiNG1 &i E ..... ..... ....... .. tT .. .
i'. . C.C. a • • • a l.r MIA
ZIP
WA. ST. CONTRACTOR'S LICENSE # _ J z /3 ,0-2 7
EXP. DATE
:: :: ::: ': > < >
BUILDING USE (office, warehouse, etc.)
NATURE OF BUSINESS: J oc-c'-7 4 8 -
(%I 41--' /2 /S e .?. ze.t s/ vices -
WILL THERE BE A CHANGE IN USE? No 0 Yes IF YES, EXPLAIN:
WILL THERE B TORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE
BUILDING? , o 0 Yes IF YES, EXPLAIN:
PROPERTY OWNER YYl G`i-RD / i - J� / �D S �, , �
PHONE 6,gy
ADDRESS F,?/ ,, No /e r - /f/ C' / Le- 7Y /or/
pjo E y 7
Z P
9 - / 7 3 7
CONTRACTOR , , z,/ G ' 2 S / r ' ' = • , 6 , c, ..•:,1��c. (e/ / 7 : „_,t,,,
ADDRESS / /.. ,...5-1, fi ,1J .. ,,c',�,�, - „ P,e7 1 c-G1 -< g3 / D
ZIP
WA. ST. CONTRACTOR'S LICENSE # _ J z /3 ,0-2 7
EXP. DATE
>; :DES..CRIPTION<::: >:< :: >::
:::::AMOUNT.::::::
RCP..T.: # >`:
>` <::: ::DATE :> >::
B ' SICPERMI .::::: >:: <:; >:::
A T
:.,..: 1. b 0 0 : >;: >:
�
� >: >: >;:<< >:;>
::<.: <::<;: ><:::<: >:
! :E . : : > : : : : : ><:: >' : :' € ::
UNIT(S )RE...
` : : : : : >: €::> `` > '' <` :'!
fat
:: :: ::: ': > < >
> :::< :; : > : : >: : : ::':
. HE : I ..EE' : >: :: ;;
PLAN C CK..E
<;> : >: >'> :: � .' >
�
::<: ;: » :> ;
<> :'
: > » ><<<::. :: : ><> >': :
OTHER > >> >« > > »: >< >;:: > : :<< : :: ::« ::::::;
>: > :::::€ : >::::.<> ":! ;
: : :;> <; : >; > > :< >:
::! : ::«! : : : :< > :1 >: :?: :::
>;:; .:.:
;,..... TOTAL ..
CITY OF TUKWILA
Department of Community Development - Building
6300 Southcenter Boulevard, Tukwila WA 98188
(206) 431-3670
PLAN CHECK
NUMBER
a cx
APPLICATION MUST BE FILLED OUT COMPLETELY
AME c . he, c • H 6 f 97, /
BUILDING OWNER
OR
AUTHORIZED
AGENT
CONTACT PERSON ) /2 z L
APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill
out the application completely and follow the plan submittal checklist on the reverse side of this form. A completed
"Mechanical Permit Fee Worksheet” must accompany this permit application. Handouts are available at the Building
counter which provide more detailed information on application and plan submittal requirements. Application and
plans must be complete in order to be accepted for plan review.
BUILDING OWNER I AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or
contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent
to submit this permit application and obtain the permit will be required as part of this submittal.
VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the
applicant. This figure is used for budget reporting purposes only and not to calculate your fees.
EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of
application shall expire by limitation. The Building Official may extend the time for action by the applicant for a
period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform
Mechanical Code (current edition). No application shall be extended more than once.
If you have any questions about our process or plan submittal requirements,
please contact the Department of Community Development at 431 -3670.
DATE APPLICATION ACCEPTED
MECHAF.:CAL PERMIT
APPLICATION
Division
ADDRESS // <..s., „te ,ve .r
Mechanical Fee Worksheet must also be filled out
and attached to this application.
FEES (for staff use only)
DATE
CITY /ZIP
DATE APPLICATION EXPIRES
PHONE, /7 -/ 737
PHONE .,ao6
08/18/00
DESCRIPTION
UNIT COST
UNITS
X
COST
BASIC FEE
$15.00
$4.50
SUPPLEMENT PERMIT FEE
1
Installation or relocation of each forced -air gravity -type furnace or
burner, including ducts and vents attached to such appliance, up to and
including 100,000 Btu /h.
$9.00
X
2
Installation or relocation of each forced -air or gravity -type furnace or
burner, including ducts and vents attached to such appliance over
100,000 Btu /h.
$11.00
X
3
Installation or relocation of each floor furnace, including vent.
$9.00
X
4
Installation or relocation of each suspended heater, recessed wall heater
or floor- mounted unit heater.
$9.00
X
5
Installation, relocation or replacement of each appliance vent installed and
not included in an appliance permit.
$4.50
x
6
Repair of, alteration of, or addition to each heating appliance,
refrigeration unit, cooling unit, absorption unit, or each heating, cooling,
absorption, or evaporative cooling system, including installation of
controls regulated by this code.
$9.00
X
7
Installation or relocation of each boiler or compressor to and including
three horsepower, or each absorption system to and including 100,000
Btu /h.
$ 9.00
X
8
Installation or relocation of each boiler or compressor over three
horsepower to and including 15 horsepower, or each absorption system
over 100,000 Btu /h and including 500,000 Btu /h.
$16.50
X
9
Installation or relocation of each boiler or compressor over 15
horsepower to and including 30 horsepower, or each absorption system
over 500,000 Btu /h to and including 1,750,000 Btu /h.
$22.50
X
10
Installation or relocation of each boiler or compressor over 30
horsepower to and including 50 horsepower, or for each absorption
system over 1,000,000 Btu /h to and including 1,750,000 Btu /h.
$33.50
x
11
Installation or relocation of each boiler or refrigeration compressor over
50 horsepower, or each absorption system over 1,750,000 Btu /h.
$56.00
X
12
Each air - handling unit to and including 10,000 cubic feet per minute,
including ducts attached thereto. (NOTE: This fee shall not apply to an
air - handling unit which is a portion of a factory- assembled appliance,
cooling unit, evaporative cooler or absorption unit for which a permit is
required elsewhere in this code.)
$6.50
X
13
Each air - handling unit over 10,000 cfm.
$11.00
X
14
Each evaporative cooler other than a portable type.
$6.50
X
15
Each ventilation fan connected to a single duct.
$4.50
x
16
Each ventilation system which is not a portion of any heating or
air - conditioning system authorized by a permit.
$6.50
V
X
6v.,
17
Installation of each hood which is served by mechanical exhaust, including
the ducts for such hood.
$6.50
X
18
Installation or relocation of each commercial or industrial -type incinerator.
$1 1.00
X
19
Installation or relocation of each commercial or industrial -type incinerator.
$45.00
X
20
I
Each appliance or piece of equipment regulated by the code but not
classed in other appliance categories, or for which no other fee Is listed in
this code.
$6.50
X
06/IWGO
SUBTOTAL
r 1 50
PLAN CHECK FEE (25% of
subtotal)
S. ��
GRAND TOTAL
$ ( ND
V 0
CITY OF TUKWILA 'r
Department of Community Development - Building Division
6300 Southcenter Boulevard, Tukwila WA 98188
(206) 431 -3670
THIS WORKSHEET MUST ACCOMPANY
YOUR MECHANICAL PERMIT APPLICATION.
MECHAN' :AL PERMIT
FEE WORKSHEET
7NS < C omplete ; tl e ;. orks eet,
ng t number of units be ing
d. in each c a t egory. t t ime
a l, :staff will calculate the fees. .
Ft.AN REVIEW COMMEL,. TS
Plan Check No.: Mq2- t02Z Project: MEPTIRL
REQUIRED INSPECTIONS
No changes will be made to the plans unless approved by the Architect
and the Tukwila Building Division.
ff ? Plumbing permit shall be obtained through the King County Health
Department and plumbing will be inspected by that agency, including all
gas piping (296- 4722).
Electrical permit shall be obtained through the Washington State Division
of Labor and Industries, and all electrical work will be inspected by that
agency (277- 7272).
4. All mechanical work shall be under separate permit through the City of
Tukwila.
Q All permits, inspection records, and approved plans shall be posted at the
job site prior to the start of any construction.
6. When special inspection is required, either the owner, architect or
engineer shall notify the Tukwila Building Division of appointment of the
inspection agencies prior to the first building inspection. Copies of all
special inspection reports shall be submitted to the Building Division in a
timely manner. Reports shall contain address, project name and permit
number of the project being inspected.
7. All structural concrete to be special inspected (Sec. 306, UBC).
8. All structural welding to be done by W.A.B.O. certified welder and special
inspected (Sec. 306, UBC).
9. All high - strength bolting to be special inspected (Sec. 306, UBC).
10. Any new ceiling grid and light fixture installation is required to meet lateral
bracing requirements for Seismic Zone 3.
11. Partition walls attached to ceiling grid must be laterally braced if over eight
(8) feet in length.
Readily accessible access to roof mounted equipment is required.
13. Engineered truss drawings and calculations shall be on site and available
to the building inspector for inspection purposes. Documents shall bear
the seal and signature of a Washington State Professional Engineer.
Any exposed insulations backing material to have Flame Spread Rating of
25 or less, and material shall bear identification showing the fire
performance rating thereof.
15. Subgrade preparation including drainage, excavation, compaction, and
fill requirements shall conform strictly with recommendations given in the
soils report prior to final inspection (see attached procedure).
16. A statement from the roofing contractor verifying fire retardancy of roof
will be required prior to final inspection (see attached procedure).
All construction to be done in conformance with approved plans and
requirements of the Uniform Building Code (1988 Edition), Uniform
Mechanical Code (1988 Edition), Washington State Energy Code (1990
Edition Banter`f ree ity(199II...
on`
18. All food preparation establishments must have King County Health
Department sign -off prior to opening or doing any food processing.
Arrangements for final Health Department inspection should be made by
calling King County Health Department, 296 -4787, at least three working
days prior to desired inspection date. On work requiring Health
Department approval, it is the contractors responsibility to have a set of
plans approved by that agency on the job site.
19. Fire retardant treated wood shall have a flame spread of not over 25. All
materials shall bear identification showing the fire performance rating
thereof. Such identification shall be issued by an approved agency
having a service for inspection at the factory.
20. Notify the City of Tukwila Building Division prior to placing any concrete.
This procedure Is in addition to any requirements for special inspection.
21. All spray applied fireproofing, as required by U.B.C.' Standard No. 43 -8,
shall be special inspected.
22. All wood to remain in placed concrete shall be treated wood.
23. All structural masonry shall be special inspected per U.B.C. Section 306
(a) 7.
Validity of Permit. The issuance of a permit or approval of plans,
specifications and computations shall not be construed to be a permit for,
or an approval of, any violation of any of the provisions of this code or of
any other ordinance of the jurisdiction. No permit presuming to give
authority or violate or cancel the provisions of this code shall be valid.
25. A Certificate of Occupancy will be required for this permit.
1. Footings
2. Foundation
3. Slab /Slab Insulation
4. Shear Wall Nailing
5. Roof Sheathing Nailing
6. Masonry Chimney
7. Framing
8. Insulation
9. Suspended Ceiling
10. Wall Board Fastening
/
11 `• bO 644 -!
12.
13.
14. Fire Final
15. Planning Final
16. Public Works Final
X 17. Building Final
Ft.AN REVIEW COMMEL,. TS
Plan Check No.: Mq2- t02Z Project: MEPTIRL
REQUIRED INSPECTIONS
No changes will be made to the plans unless approved by the Architect
and the Tukwila Building Division.
ff ? Plumbing permit shall be obtained through the King County Health
Department and plumbing will be inspected by that agency, including all
gas piping (296- 4722).
Electrical permit shall be obtained through the Washington State Division
of Labor and Industries, and all electrical work will be inspected by that
agency (277- 7272).
4. All mechanical work shall be under separate permit through the City of
Tukwila.
Q All permits, inspection records, and approved plans shall be posted at the
job site prior to the start of any construction.
6. When special inspection is required, either the owner, architect or
engineer shall notify the Tukwila Building Division of appointment of the
inspection agencies prior to the first building inspection. Copies of all
special inspection reports shall be submitted to the Building Division in a
timely manner. Reports shall contain address, project name and permit
number of the project being inspected.
7. All structural concrete to be special inspected (Sec. 306, UBC).
8. All structural welding to be done by W.A.B.O. certified welder and special
inspected (Sec. 306, UBC).
9. All high - strength bolting to be special inspected (Sec. 306, UBC).
10. Any new ceiling grid and light fixture installation is required to meet lateral
bracing requirements for Seismic Zone 3.
11. Partition walls attached to ceiling grid must be laterally braced if over eight
(8) feet in length.
Readily accessible access to roof mounted equipment is required.
13. Engineered truss drawings and calculations shall be on site and available
to the building inspector for inspection purposes. Documents shall bear
the seal and signature of a Washington State Professional Engineer.
Any exposed insulations backing material to have Flame Spread Rating of
25 or less, and material shall bear identification showing the fire
performance rating thereof.
15. Subgrade preparation including drainage, excavation, compaction, and
fill requirements shall conform strictly with recommendations given in the
soils report prior to final inspection (see attached procedure).
16. A statement from the roofing contractor verifying fire retardancy of roof
will be required prior to final inspection (see attached procedure).
All construction to be done in conformance with approved plans and
requirements of the Uniform Building Code (1988 Edition), Uniform
Mechanical Code (1988 Edition), Washington State Energy Code (1990
Edition Banter`f ree ity(199II...
on`
18. All food preparation establishments must have King County Health
Department sign -off prior to opening or doing any food processing.
Arrangements for final Health Department inspection should be made by
calling King County Health Department, 296 -4787, at least three working
days prior to desired inspection date. On work requiring Health
Department approval, it is the contractors responsibility to have a set of
plans approved by that agency on the job site.
19. Fire retardant treated wood shall have a flame spread of not over 25. All
materials shall bear identification showing the fire performance rating
thereof. Such identification shall be issued by an approved agency
having a service for inspection at the factory.
20. Notify the City of Tukwila Building Division prior to placing any concrete.
This procedure Is in addition to any requirements for special inspection.
21. All spray applied fireproofing, as required by U.B.C.' Standard No. 43 -8,
shall be special inspected.
22. All wood to remain in placed concrete shall be treated wood.
23. All structural masonry shall be special inspected per U.B.C. Section 306
(a) 7.
Validity of Permit. The issuance of a permit or approval of plans,
specifications and computations shall not be construed to be a permit for,
or an approval of, any violation of any of the provisions of this code or of
any other ordinance of the jurisdiction. No permit presuming to give
authority or violate or cancel the provisions of this code shall be valid.
25. A Certificate of Occupancy will be required for this permit.
Address: 12200 EAST MARGINAL WY S
Permit No: M92 -0022
Type: B -MECH
Location:
Parcel #: 734560 -0045
CITY TUKWILA
CONDITIONS
NRES
Status: ISSUED
Applied: 01/22/1992
Issued: 01/30/1992
************ * * * * * * *y4******** *k**** ** *fir**** Ark* ** * *** * *** *** *k****** *** ** **
Permit Conditions:
1. No changes will be made to the plans unless approved by the
Architect and the Tukwila Building Division.
2. Plumbing permit shall be obtained through the Seattle -King
County Department of Public Health. Plumbing will be
inspected by that agency, including all gas piping
(296- 4722).
3. Electrical permit shall be obtained through the Washington
State Division of Labor and Industries and all electrical
work will be inspected by that agency (277- 7272).
4. All permits, inspection records, and approved plans shall be
maintained available at the job site prior to the start of
any construction. These documents are to be maintained
available until final inspection approval is granted.
5. Readily accessible access to roof mounted equipment is
required.
6. Any exposed insulations backing material shall have a Flame
Spread Rating of 25 or less, and material shall bear identi-
fication showing the fire performance rating thereof.
7. All construction to be done in conformance with approved
plans and requirements of the Uniform Building Code (1988
Edition), Uniform Mechanical Code (1988 Edition), Washington
State Energy Code (1991 Edition).
8. Validity of Permit. The issuance of a permit or approval of
plans, specifications and computations shall not be con-
strued to be a permit for, or an approval of, any violation
of any of the provisions of this code or of any other
ordinance of the jurisdiction. No permit presuming to give
authority or violate or cancel the provisions of this code
shall be valid.
COMMENTS:
•
llll�;;��
Special Instructions:
I
Requester:
Phone No.:
t
r (1Z .,.. ei.0K . ,
. L.r..,4.
4
0/-36)(05 a
.. . . Se A e. t-
r
,
r ..
ro Got:
ype o nspe 1 11.1i7
) • teCales: AMMIll
Date Wanted .
llll�;;��
Special Instructions:
I
Requester:
Phone No.:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Approved per applicable codes.
Inspector:
PR
(206) 431 -3670
❑ Corrections required prior to approval.
Dale: d r 29- qv
❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at
6300 Southcenter Blvd., Suite 100, Call to schedule reinspection.
Receipt No.:
Date:
•
MIT 1 GENERAL
1.01 SCOPE
A. The work under this Contract shall consist of furnishing all labor, supervision, materials and
equipment required to install a Dust Collection system, a new passage door, and appurtenances at
the South Base Unit Repair Building's Bead Blast Room.
II. This Work includes, but is not limited to, the following activities as required for complete installation
of the Dust Collection system.
1. Install Metro furnished Dust Collector machine, (Torit modet84) on the roof of Unit Repair
Building.
2. FUmish and install galvanized sheet metal air duct between the Bead Blasting machine and
Dust Collector machine.
' 3. Construct an opening inthe Unit Repair Building's roof for 8" duct penetration, and modify a
portion of the existing roofing for the Dust Collection machine and duct support curb
installation.
4. Furnish and install support curbs for the Metro furnished Dust Collector machine and the air
duct at the roof, and restore roofing.
5. Furnish and install electric conduit, wire and disconnect switch for the Dust Collector machine.
6. Furnish and install motor starters, timing relays and control panel enclosure for the Bead Blast
and Dust Collector machines.
7. Furnish and install a new wood door on the Bead Blast room entrance.
PART 2 PRODUCTS
Not used.
PART 3 EXECUTION
Not used.
..1
SECTION 01010
SUMMARY OF WORK
END OF SECTION
RECEIVED
CITY OF TUKWiIA
JAN 2 2 1992
PERMIT CENTER
0.1010.1 8W 01.40
•
q
N CONTeACJOR'
-4
ATTEE
r
•
SOUTH
BASE
COACH PARKING
FUEL AND WASH
BUILDING
HAZARDOUS
STORAGE
SHED
SITE PLAN
SCALE: 1 100'
•
RECEIVED
CITY OF TUKWILA
JAN 22 1992
PERMIT CENTER
DWO SHEET DE
NO, NO.
otot I SIT
M101 2 PU
M102 3 MEI
ARt
DRAWING 1NI
•
PROJEI
BEAD
:mETRD
Municipality of Metropolitan Seattle
Exchange Building • 821 Second Ave. • Seattle, WA 98104 -1598 •(206) 684 -2100
JAN \ z899Z
p� `I11`
Mr. Ken Nelson pL.A
Department of Community Dever` ment - Permit Center
6300 Southcenter Boulevard
Tukwila, Washington 98188
January 27, 1992
Bead Blast Room Ventilation Modifications
Contract No. SW91 -40
ARMS No. C76022; Task No. X16
Ref: Tukwila Mechanical Permit No.: M92 -0022
Dear Mr. Nelson:
10- 02.074
X16
A telephone dialogue was initiated by Gerrie Jackson of
Metro's Right of Way department and yourself on January 16,
1992. Ms. Jackson described the proposed project and queried
if it was required to obtain a building permit for the
project. You had indicated that a building permit was not
required but you did request a letter from the engineer. The
purpose of this letter is to meet that request.
The bead blast room dust collector machine will be installed
on the existing Unit Repair building roof as shown on the
contract drawings. The dust collector machine is a Torit
Model 84 cabinet type with 48" height by 28" width by 28"
depth dimensions, and weighs 380 pounds (approximately
equivalent to 2 people). Copies of the dust collector data
sheets are attached for your information.
Considering the size and weight of the selected dust collector
machine, the provision of a nominal 8" diameter duct
penetration opening, and the structural capacity of the
existing Unit Repair building, the project will not adversely
impact the building's roof structure.
Please attach this letter to the mechanical permit application
submitted by Miller Sheetmetal, Inc., Permit No. M92 -0022.
Mr. Ken Nelson
January 27, 1992
Page Two
If you have any questions, please feel free to call Merdad
Shaverdian at 684 -2023 or the undersigned at 684 -1706.
Very truly yours,
Cloyd Jack P.E.
Project Engineer
CJ:jym /mskA
attachment
cc: Merdad Shaverdian - 117
•
EFFICIENT DESIGN
Torit's cabinet dust collectors cover
a wide range of dust applications.
Accessories are available to meet a
variety of your dust collection
needs.
With the fan on the clean air side,
dust and other collected material
are filtered out by the fabric filter
before reaching the fan, resulting in
long, reliable performance.
Models 50 through 80 are easily
portable, providing you the
flexibility to move the collector
wherever it is needed. Their small
footprints mean they can be placed
close to critical machinery using
little valuable floor space.
J
EXCELLENT FILTRATION CAPABILITY
The envelope filters used in Torit's cabinet model dust
collectors provide you with very high collection efficiencies,
trapping dust particles of all sizes, including those smaller
than one micron. They are rated at 99.9 %+ collection
efficiency by weight even with high concentrations of sub
micron particles in the airstream.
LOWERS ENERGY COSTS
The highly efficient filtration of the Torit cabinet collectors
allows you to recirculate heated or cooled plant air. This
translates directly to lower energy costs.
EASY CLEANING
Most collected dust settles immediately into the pull out dust
drawer or hopper base. Manually operating the filter shaker
easily dislodges dust that clings to the fabric filters.
150 SERIES CABINET
60 SERIES CABINET
70 SERIES CABINET
80 SERIES CABINET
NUMBER OF FILTERS
24
24
24
30
FILTER DIMENSIONS
12.3/4" x 7-1/2"
18.314" x 10-1/2"
18-3/4" x 20.1/2"
18 -3/4" x 20-1/2"
ACTUAL FILTER AREA
30 SOFT.
60 SOFT.
120 SO.FT.
150 SOFT.
BLOWER MOTOR
(SPECIFY OPERATING
VOLTAGE WHEN ORDERING)
STANDARD VOLTAGE
1/2 HORSEPOWER
1/2 OR 3/4 HORSEPOWER
1 HORSEPOWER
1 -1/2 OR 3 HORSEPOWER
208 /230/ 460 /60/3
208/ 230 /460/60/3
208 /230/460/60/3
208 /230/460/60/3
OUST STORAGE AREA
DUST DRAWER
HOPPER
.34 CU. FT.
1.86 CU. FT.
.43 CU.FT.
2.34 CU.FT.
.93 CU.FT.
2.34 CU.FT.
2.0 CU.FT.
3.16 CU.FT.
AIR INLETS
SEE DRAWING FOR LOCATION AND MULTIPLE RATINGS TABLES FOR SIZE
STANDARD FINISH
INDOOR BLUE
INDOOR BLUE
INDOOR BLUE
INDOOR BLUE
FLOOR SPACE
REQUIREMENT MEN
19-1/2" x 22-13/32"
25-5/8" x 22-13/32"
25-5/8" x 22- 13/32"
28 -5/8" x 28- 15/32"
APPROXIMATE SHIPPING WEIGHT
WITH DUST DRAWER
WITH 5 GALLON PAIL
WITH 55 GALLON DRUM
150 LBS.
236 LBS.
NA
170 LBS.
265 LBS.
298 LBS.
245 LBS.
340 LBS.
372 LBS.
365 LBS.
472 LBS.
495 LBS.
SPECIFICATIONS
LT3PLE RAT3NG TABLES
50 SERIES CABINETS
MODEL
54 CABINET VELOCITY
1/2 HP C.F.M. (F.P.M.)
One 3" 284 5804
Inlet 231 4705
171 3491
60 SERIES CABINETS
MODEL
66 CABINET VELOCITY
1/2 HP C.F.M. (F.P.M.)
One 3" 323 6581
Inlet 263 5374
196 4005
136 2775
MODEL C.F.M.
64 CABINET PER VELOCITY
3/4 HP INLET (F.P.M.)
One 4" 500
Inlet 426
323
Two 3" 267
Inlets 232
184
One 3"
Inlet
307
256
188
5720
4905
3709
5447
4739
3758
6269
5222
3842
70 SERIES CABINETS
MODEL C.F.M.
75 CABINET PER VELOCITY
1 HP INLET (F.P.M.)
One 4"
Inlet
Two 3"
Inlets
550
500
450
400
325
290
230
One 3" 335
Inlet 300
200
175
6322
5747
5172
4598
6633
5918
4694
6837
6122
4082
3571
EXTERNAL
STATIC PRESSURE
(INCHES W.O.)
3.16
3.35
3,55
EXTERNAL
STATIC PRESSURE
(INCHES W.O.)
4.20
4.32
4.45
4.78
EXTERNAL
STATIC PRESSURE
(INCHES W.O.)
3.50
3.90
4.50
2.75
3.30
4.00
3.75
4.00
4.30
4.90
5.30
5.40
5.50
4.50
4.90
5.40
4.70
4.90
5.30
5.40
EXTERNAL
STATIC PRESSURE
(INCHES W.O.)
Specifications subject to change without notice.
PRESSURE DROP
CLEAN FILTER
(INCHES W.O.)
0.45
0.35
0.30
PRESSURE DROP
CLEAN FILTER
(INCHES W.U.)
0.36
0.25
0.22
0.16
PRESSURE DROP
CLEAN FILTER
(INCHES W.O.)
0.80
0.60
0.45
0.84
0.67
0.54
0.40
0.35
0.26
PRESSURE DROP
CLEAN FILTER
(INCHES W.O.)
0.72
0.65
0.58
0.48
0.90
0.80
0.60
0.40
0.30
0.20
0.15
80 SERIES CABINETS
MODEL
81 CABINET
1-1/2 HP
One 6"
Inlet
Two 4"
Inlets
One 4"
Inlet
MODEL
64 CABINET
3 HP
One 8"
Inlet
Two 4"
Inlets
One 5"
Inlet
One 4"
Inlet
C.F.M.
PER VELOCITY
INLET (F.P.M.)
1071
987
874
524
475
418
599
5482
5034
4460
6021
5462
4806
6890
493 5664
424 4873
C.R.M. EXTERNAL
PER VELOCITY STATIC PRESSURE
INLET • (F.P.M.) (INCHES W.O.)
1231
1143
1036
875
652
573
438
1155
997
789
700
610
505
6281
5831
5283
4460
7493
6581
5034
8491
7330
5804
8050
6994
5804
EXTERNAL
STATIC PRESSURE
(INCHES W.O.)
3.70
4.20
4.70
3.75
4.50
5.00
4.80
5.00
5.00
5.00
5.80
6.60
7.30
5.90
6.85
7.90
7.80
8.90
8.55
7.75
7.80
7.80
PRESSURE DROP
CLEAN FILTER
(INCHES W.O.)
1.15
1.05
0.90
1.05
0.90
0.75
0.45
0.30
0.25
PRESSURE DROP
CLEAN FILTER
(INCHES W.O.)
2.05
1.85
1.78
1.05
2.20
1.85
1.05
1.85
1.75
0.89
0.59
0.46
0.31
•
CABINET MODEL
NUMBER
A
B
OIMENSION
C
IINCHESI
0
E
F
50 SERIES CABINETS
21.11/16
26-11/16
19.1/2
2-7/8
11-3/16
22.13/32
60 SERIES CABINETS
25-11/16
32-31/32
25-5/8
3-7/32
11-3/16
22-13/32
70 SERIES CABINETS
36-5/16
43-19/32
25-5/8
3-7/32
11-3/16
22-13/32
BO SERIES CABINETS
40-9/16
47.27/32
28-5/8
4-9/16
14-7/32
28.15/32.
;.:% �. i /
. 1 \ . .
i�ti lM,
r 'RIGHT;SIOE -`k'
t7. 't • 1' z ccy
• .�, Jul � �1•
A
•
STANDARD FEA
• Heavy gauge, sturdy, welded cabinet
• TEFC motor
• Factory installed, high efficiency filters
• Inlet locations on the top and all 3 sides
OPTIONAL EQUIPMENT
• Automatic shaker
• 5 gallon pail pack
• 55 gallon drum pack on
series models 60, 70, and 80
• Gates on 5 gallon pail and
55 gallon drums
• Hoppers as shown on
dimensional drawings
• Dump hoppers
D]MENS3ONAL DRAWING
(See back page for Cabinet Models with hoppers.)
BLOWER
SECTION
FILTER
SECTION
CLEAN AIR
OUTLET
12" CLEARANCE (MINIMUM)
ABOVE CLEAN AIR OUTLET
NOTE:
All dimensions are reference only.
• Inlet collar kits
• Explosion proof motors
• Choice of fabric for filters
• Weather protective paint
• Exhaust deflector
• Chamber, attenuator or
stack silencer
• Suction tube assembly
dws ?�;. •
CABINET MODELS WITH DUST DRAWER
ELECTRIC
POWER
CABLE
HOLE
C
• Dynamically balanced fan wheel
• Galvanized dust drawer and shaker bar
• Indoor, industrial grade texturized paint finish
OUST DRAWER
• Casters for portability
• Outrigger pack
• Explosion vent
• HEPA filter
• Motor starters
• Magnehelic gauge
• 50 cycle, single phase,
other voltages available
AIR INLET
Exteinal
Static .-
Pressure
- ` Standard •
- . Inlet
: _: Outlet
Motor
Filter
Cloth
Area
(sq. ft.)
Dust
Storage
Efficiency in one neat, compact, self- contained unit
TORIT's large selection of cabinet -style fabric filter
dust collectors gives you the kind of flexibility needed
in today's rapidly changing technology. These models
have a range of from 171 CFM up to 8000 CFM. Storage
capabilities run from 0.34 cubic feet to 500 cubic feet.
And fabric filter areas range from 30 to 1,200 square
feet. On models with less than a 300 - square -foot filter
area, pull -out drawers, large- capacity hopper -type
bases and 55- gallon drum arrangements are offered.
Available with a number of power packages and other
options, the modular design and small space require-
ments make them quick to install and easy to move.
Designed for effectiveness
These welded steel cabinet systems house motor and
blower on the clean -air side, eliminating the risk of
fan loading, motor damage and the ultimate time -
consuming expensive repairs. Overall collection
efficiencies exceed +99.9% by weight, on both heavy
chips and fine particulate. This kind of efficiency
makes it possible to recirculate the cleaned air in-
doors, where allowable, saving on costly heated or
conditioned air.
Cleaning simplicity
TORIT fabric filter dust collectors are also easy to
empty and easy to clean, whether dust - drawer, hop-
per -type or 55- gallon drum arrangement. Particles
clinging to the filter bags are easily dislodged by
actuating the manual filter shaker handle. Fully -
automatic filter cleaning is available as an option on
all models.
16 good reasons to think
TORIT cabinet collector systems
There are sixteen basic models in TORIT's fabric
filter cabinet line. Others are available as variations
of these models. Please check the cabinet model sec -'
tion of TORIT's full -line catalog for a complete listing.
Or talk to a TORIT representative.
Many optional variations in locations, number and
size of inlets are available. For additional information,
request bulletin by product model number.
*Ratings are determined with new clean filters. After a series of dust loadings, performance will recover to approximately 80% of rated cfm upon shaking.
CABINET MODEL
NUMBER
0
DIMENSION
N
(INCHES►
J
K
50 SERIES CABINET
62.1/32
57-1/32
19 -9/32
16-1/32
60 SERIES CABINET
68.5/16
61-1/32
19-9/32
22-3/32
70 SERIES CABINET
78 -15/16
71-21/32
19-9/32
22-3/32
BO SERIES CABINET
83-3/16
75-29/32
25 -5/32
25-5/32
CABINET MODEL
NUMBER
DIMENSION (INCHES)
L I M I N I 0
50 SERIES CABINET
NOT AVAILABLE
60 SERIES CABINET
86-25/32
94-3/32
28-13/32
22-15/32
70 SERIES CABINET
97-13/32
104-23/32
28 -13/32
22-15/32
BO SERIES CABINET
101-21/32
108.15/16
30-5/32
25-3/8
'DIMENSIONAL DRAWING
CABINET MODELS WITH 5 GALLON PAIL PACK
G
CABINET MODELS
WITH 5 GALLON PAIL PACK
H
torit
•
35 -3/8"
1
21"
STD.
CLEAR.
1
AIR INLET
Donaldson Company, Inc.
Donaldson Industrial Group
P.O. Box 1299
Minneapolis, MN 55440
612- 887 -3900
Parts & Service
1- 800 - 365 -1331
BLOWER
SECTION
FILTER
SECTION
Torlt — the industrial air pollution problem solvers.
CLEAN AIR AIR INLET
OUTLET
12" CLEARANCE (MINIMUM)
ABOVE CLEAN AIR OUTLET
CABINET MODELS WITH 55 GALLON DRUM PACK
N-1.4
NOTE: All dimensions are reference only.
CABINET MODELS
WITH 55 GALLON DRUM PACK
11-1/4"
10"
11 - ia"
110 ,.
HOPPER FLANGE
DETAIL
1/2" DIA.
12 HOLES
AIR INLET
1- «- -o--•!
1
81 -1/8"
48"
STD.
CLEAR.
M
Copyr ight so-do
ORIT 1990
Printed In U.S.A.
•
rtoor
'
W iiiii Iaii
4itiii
i mi
kal
1,
. i T" n n, t t J Al ' I O N OW
q e.t.YTS I AUST BE. CC AT 1:;•
rt
7E'4 L r . \ C. 5'ECTIOMS 4 o 6
A1AD Ito `(3)
I understand that the Plan Check approvals are
subI ect'to errors and 6iiiissions and approval bI
;Mans does not 2u'tVSCrrze the P eceipt n o I cdn•
scopY
code :or ordi rrc ,
adopted co na , l aps ackr0 M 0d • 9d
trac � Of:3�" ov'
/ice
REVISION
OP RA ON
BLDG.
RETENTION
POND
DATE
STORAGE
SHED
COACH PARKING
HAZARDOUS=
STORAGE
SHED
STAFF
PARK I NG
DRAWING INDEX
PROJECT LOCATION
BEAD BLAST ROOM
DESCRIPTION
SITE PLAN, VICINITY MAP & INDEX
PLANS & SECTIONS
MECHANICAL, ELECTRICAL, &
ARCHITECTURAL DETAILS
VASHON
ISLAND
.�. I ......,
r �a
BIM
ANY
KENMORE BO
If
WASHINGTO
BELLEVUE
EDMOND
DES
OINE
R OJiJCT LOCATION
ISSAQUAH
ALGONA
PACI
TACOMA
DRAWN: CHECKED:
f ? �
RECOMMENDED:
VICINITY MAP
0 .. 2 3 4 5
BLACK
DI OND
• DUVALL
UNIT. REPAIR FACILITY
BEAD BLAST ROOM VENTILATION MODIFICATIONS
CARNATION
I n
RECEIVED
( rry TUKWILA
JAN2r 1992
PERMIT CENTER
Municipality of Metropolitan Seattle
FILE. NO;
' NORT
BEND
DATE:
NOV. 1991
DRAWING NO:
GI01
SHEET NO: OF
1 3
A
n C D
•
M101
M102
II lit J!Ili' Irrr irl.rfr1
No.18 ,...
SITE PLAN
VICINITY MAP & INDEX
..wrr...
•H
[ili0hliiTtoiiiiitiliitli
I
iiiiirnhilifilit4Inti
REPLACE EXISTING
DOOR SEE
O
A
1
EXISTING EQUIPMENT
IN ' ROOM, TYP OF 5
BEAD BLAST ROOM
SCALE: 3/8 "= ,j, -0"
BEAD BLAST ROOM
RM. 154
I5
EXISTING ROOF
WALKING /ACCESS
PATH
ROOF PLAN
EXIST!
BLAST
SCALE: I/8 "= I'-0"
B
'ICS
IBIS
14
T
1—
v
11
_
AN Am
•
•MN
--■
HV-18
AC -5
la 1
DUST. COLLECTOR
MACHINE I
0
1.1
C
S .YYYYIYY..�YI■ I_I.1�
EXISTING SAFETY SWITCH
30 AMP, 600 VOLT
EXISTING SHAKER
CONTROL PANEL
NG BEAD
MACHINE
COVER TWO EXISTIN
OPENINGS WITH GALV.
#16 GAUGE SHEET
METAL TO FORM
AIRTIGHT SEAL
DUST COLLECTOR—
MACHINE
TORIT MODEL #84
SEE NOTE 1
DUCT SUPPORT
SEE DETAIL
DUCT SUPPORT
SIMILAR TO
DETAIL
EXISTING SAFETY"
SWITCH 30 AMP,
600 VOLT
FLEXIBLE
CONNECTION
5" X 5" AC CESS
HOLE
MI MI
C
DISCHARGE
GOOSENECK
FAN ACCESS DOOR
FILTER ACCESS DOOR
DUST TRAY
SEE
FOR DUST COLLECTOR
SUPPORT CURB
VOLUME DAMPER
4 "0 DUCT
SLOT -HOOD
SEE DETAIL
3 "X 3" `HINGED
ACCESS DOOR
EXISTING
ROOF t
STRUCTURE
EXISTING
SUSPENDED
CEILING
4 "0 BACKDRAFT
DAMPER, PROVIDE
6 "> 6" ACCESS DOOR
TO DAMPER
`— CONNECT TO EXISTING
11 "x 3" OPENING
No. 1 1
E
20"
11111111111111 �1� 11 11 ,,I11111111111, I1r111'1I1I1111 II11111111111 111111 1111111
1 � 4 1 5 1 � 1. 6
F
CONNECT 8 "0 DUCT
TO BACKSIDE OF
TORIT "' UNIT, FORM
AIRTIGHT SEAL
FLEXIBLE CONNECTION
8"0
SEE DETAIL
FOR ROOF PENETRATION
SEAL AROUND PENETRATIONS
WITH CAULKING MATERIALS
FLEXIBLE CONNECTION
EXISTING BEAD BLAST
MACHINE
.r
SUPPORT 8"0 DUCT
EVERY 6 FEET SEE
DETAIL
No.
REVISION
DATE
DESIGNED:
%
RECOMMENDED:
CHECKED:
AS NOTED
litan Seattle
UNIT REPAIR FACILITY
BEAD BLAST ROOM VENT1LUTAT1ON MODIFICATIONS
NOV. 1991
FILE_ NO:
X16
DRAWING NO:
SHEET NO: OF
SECTION
SCALE : 3/4 "= ` I ' -0"
SCALE:
4rnFTRD
G
3/16" x 1 --1/2"
PIPE SPIKE -WEDGE ANCHORS
1/4" THREADED ROD
DUCT SUPPORT
DETAIL
SCALE: NTS
INSIDE RAP (US OF STRAP TO MATCH
•
OUTSIDE RADIUS OF DUCT
8 "0 DUCT
12"X 12"
TO 8"o
TRANSITION
- 12"X 12"
GALVANIZED
SHEET METAL
FLEXIBLE
CONNECTION
LEGEND.
H
NOTES
1. INSTALL METRO FURNISHED DUST COLLECTOR MACHINE,
TORIT MODEL #84.
2. FOR ELECTRICAL WIRING SCHEMATIC SEE DRAWING M102.
Municipality of Metro
NEW CONSTRUCTION
EQUIPMENT TO BE INSTALLED,
SUPPLIED BY METRO
EXISTING EQUIPMENT
OR STRUCTURES
'10\
S \*
►N 1\ ‘`IO
Mr/ nc'TI IKWILA
JAN 2 2 1992
PEHMIT CENT f
DATE:
kriiltiall 1
_;� °`,..
Illintiiigit'liNititt
In [
ill
rrIt'Imitit
Min
I
START
EXISTING
S WITCH
�o �o
ON THE
BEAD
BLAST
MACHINE
120
SHAKER
CONTROL
CONTROL
TRANSFORMER
1TR (INSTANTANEOUS)
2TR (INSTANTANEOUS)
O.L.'S
2 EXISTING 150
WATT LAMPS INSIDE
THE BEAD BLAST
MACHINE
SAFETY SWITCH
30 AMP,
600 VOLT
2TR
RE— CONNECT EXISTING
CONTROL TO NEW
CONTROL TRANSFORMER
BEAD BLAST
FAN .TIMER
(ADJUSTABLE
UP TO 5 ° MIN.)
DUST .p COLLECTOR
MACHINE TIMER
(ADJUSTABLE
UP TO 5' MIN.)
INOTES;
1. ALL WORK SHALL BE PERFORMED PER GOVERNING CODES;
DUST COLLECTOR MACHINE FURNISHED BY METRO'S RESIDENT ENGINEER;
• SHALL BE PLACED &w INSTALLED ` ON ROOF BY THE CONTRACTOR IN
ACCORDANCE WITH THE ' MECHANICAL SECTION OF THE SPECIFICATIONS;
• WIRING SHALL BE BY THE CONTRACTOR IN ACCORDANCE WITH THE
ELECTRICAL SECTION OF THE SPECIFICATIONS. THIS SHALL' INCLUDE ALL
COMPONENTS, % CONDUIT, WIRING & CONTROL EXCEPT 'AS ' NOTED;
• ROUTE CONDUIT FROM BEAD BLAST MACHINE ROOM TO ROOF ALONG
WITH NEW DUCT WORK;
• INSTALL SAFTY SWITCH ON DUST COLLECTOR MACHINE;
START AND
• MOUNT STOP, EMERGENCY STOP CONTROLS ON BEAD BLAST
MACHINE AT LOCATION OF. EXISTING STOP—START CONTROL; REMOVE
EXISTING STOP—START CONTROL.
• CONSTRUCT & INSTALL ' A CONTROL CABINET. THE CABINET SHALL CONTAIN
THE FOLLOWING:
' 2 , SIZE 0 MOTOR STARTERS (M1 & M2)
• CONTROL TRANSFORMER & FUSING
MO • 2 TIMERS (1TR & 2TR)
MOUNT THE CABINET ON THE WALL ADJACENT TO THE BEAD BLASTING
MACHINE'S MAIN ' POWER SAFETY SWITCH;
SHALL S
. RE —WORK THE EXISTING STOP START' PUSH BUTTON CONTROL:
EACH PUSH BUTTON BE 2N
' .0. /2N.C. WIRED AS SHOWN HERE;
REMOVE EXISTING SHAKER CONTROL TRANSFORMER AND RE- CONNECT
TO NEW CONTROL- =TRANSFORMER.
. DEPRESS THE "START" PUSH BUTTON; THE BEAD BLASTER & DUST COLLECTOR
MOTORS START;
• AT THE END OF THE BEAD BLASTING OPERATION, DEPRESS THE "TIMED STOP"
PUSH " BUTTON;
• 1TR & 2TR • ENERGIZED & HOLD THEMSELVES IN THROUGH THEIR
INSTANTANEOUS CONTACTS;
' 1TR TIMES OUT; 1TR /TDO OPENS; BEAD BLASTER MACHINE'S FAN STOPS;
1TR CIRCUIT ' IS DE— ENERGIZED;
• 2TR , TIMES' OUT; 2TR /TDO OPENS; DUST COLLECTOR'S FAN STOPS;
2TR CIRCUIT IS DE— ENERGIZED.
DETAIL
SCALE : 3"
r r I . �`Tfi�r'Ifi'
114 ip
METAL FLASHING/
• EDGE OF DUST
COLLECTOR
;. MACHINE
FORM "BOX" ALL AROUND
TO MATCH FOOTPRINT
OF DUST COLLECTOR
MACHINE
BRING ` CONDUIT ' UP
THROUGH EQUIPMENT
SUPPORT AND OUT
TO SIDEWALK
SEALANT
HYPALON FLASHING
WOOD'CANT
NAILER
VAPOR RETARDER
3-- -COURSE
REINFORCEMENT
METAL DECKING
'Intit ii��r�I��II�I�Ir r�I��'1
4.. I 5 6
No.,a : ��..r.....�.,
NOT •
1. REUSE EXISTING DOOR HARDWARE.
2 . PROVIDE PERIMETER SEALS WITH
EXTRUDED ALUMINUM_ FRAME ` AND
ADJUSTABLE CLOSED CELL SPONGE
NEOPRENE CONTACT ELEMENT.
3 . PROVIDE AUTOMATIC DROP BOTTOM
SEAL, CAM OR PLUNGER ACTIVATED.
DETAIL
SCALE: I/2 "=
NEW DOOR
. RESTORE ROOFING 'BY . A TREMCO APPROVED
CONTRACTOR TO MATCH ` EXISTING ROOFING
CURB PERIMETER SHALL
CLEAR EXISTING STEEL
ANGLE FRAME.
8 EXHAUST DUCT
4'X TX '1 -3/4"
SOLID CORE DOOR
WITH °' BIRCH VENEER
APPROVED:
DETAIL
SCALE:
SLOT HOOD
PERMIT CENTER
Municipality of Metropolitan Seattle
UNIT REPAIR FACILITY
BEAD BLAST ROOM VENTILATION MODIFICATIONS
DUCT WALL
SEALANT
GALVANIZED SHEET
METAL SCREWS
fa 3" 0.C.
METAL' FLASHING
WOOD CLEAT
NAILER
VAPOR RETARDER
3— COURSE ,
REINFORCEMENT
DATE:
NOV.' 1991
RUE NO:
X1
DRAWING NO:
H