Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M92-0060 - MUSEUM OF FLIGHT
M92-0060 MUSEUM OF FLIGHT HVAC 9404 EAST MARGINAL WAY SOUTH id0 VA03cym City of Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M92 -0060 Status: ISSUED Type: B -MECH Issued: 04/22/1992 Category: NRES Expires: 10/19/1992 Address: 9404 EAST MARGINAL WY S Location: Parcel it: 332404 -9019 Signature:_ Print Name: MECHANICAL PERMIT Date: (206) 431 -3670 Phone: 206 764 -5700 TENANT MUSEUM OF FLIGHT CHALLENGER LEARNING CENTER , 9404 EAST MARGINAL WAY SOUTH, SEATT OWNER MUSEUM OF FLIGHT FOUNDATIO 9404 E MARGINAL WAY S , 07024 -00 , SEATTLE WA , 98108 CONTACT KRAFT FENTON Phone: 206 764 -5700 MUSEUM OF FLIGHT , 9404 EAST MARGINAL WAY SOUTH, SEATTLE, WA , 9 CONTRACTOR CASCADE AIR CONDITIONING Phone: 206 784 -3135 1544 N.W. BALLARD WAY , SEATTLE, WA , , 98107 ********************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: ADD AIR HANDELING SYSTEM /DX CONDENSING UNIT WITH SUPPLY AND RETURN DUCTWORK. COOLING ONLY SYSTEM WHICH ACTS AS A SUBSYSTEM OF A 85,000 CFM FAN SYSTEM. UMC Edition: 1988 Valuation: 15,000,00 Total Permit Fee: 30.00 ********,******************.*************** * * * * * * * * * * * * * * * * * * * * ** *4 * * * ** culteop Permit Center'Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to be. true -and correct. All provisions•of law:and ordinances governing this work will be complied with, whether specified herein or not. The granting.of this permit does not presume to•give authority to violate or cancel the any other'state,or local•laws regulating construction ,. or. the performance of Work. I am authorized to sign . for and obtain this building permit. This permit shall become null and void . °`i the .. work is not commenced within 180 days from the date of issuance, or if the work is. suspended or abandoned for a period of 180 days from the last inspection. PERMIT NO, CONTACTED L.91--k- rn- DATE READY DATE NOTIFIED ( _, c Y: ( PERMIT EXPIRES 2nd NOTIFICATION BY: (init.) AMOUNT OWING 3o. oA)■ 3RD NOTIFICATION BY: (Init.) MECHANICAL PERMIT APPLICATION TRACKING PLAN CHECK NUMBER rncia ooloo PROJECT NAME SITE ADDRESS SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". DEPARTMENTAL REVIEW "X" In box Indicates which departments need to review the project. RA71iw : UISEM IVTS ' > 1 BUILDING - CONSULTANT: Date Sent Date Approved initial review 3 I , - D _ + II I 9 1, FIRE PROTECTION: ll Sprinklers ) Detectors (1 N/A 141/6 / 6-) INIT: FIRE DEPT. LETTER DATED: t /z. INSPECTOR: �� pL FIRE O PLANNING O OTHER REVIEW COMPLETED INIT BUILDING - final rAviaw 4 67-- INIT: ZONING: IBAR/LAND USE CONDITIONS? f Yes fl SCREENING REQUIRED? fYes (l No INIT: REFERENCE FILE NOS.: UMC EDITION (year): ce+rn90 9414 East Marginal Way S. • Seattle, Washington . 98108 -4097 FAX (206) 764 -5707, • (206) 764 =5700 SITE ADDRESS SUITE # 9 9 b y F_„ 11 ,, ■,,1,, 94i ' VALUE OF CONSTRUCTION - $ /S c? , r ), PROJECT NAME/TENANT / 1 ! (I S um or F L IGIn- ( C M- Lt i6LR LEMMING (tNTER) TYPE OF WORK: 0 New /Addition Q Modifications Q Repair Q Other: DESCRIBE WORK TO BE DONE: Add Ea�v4h; Co i'tvy A)v 14,01 SysfvvHa' /DX <ck,4e'h5 /..7 t4I w,lIt ca 0,444.-u✓61 duc14.4A, Couity 0„iy sys'4ow, .Vik11 cc as cc saiisydewl df 4 1Sc, sys`al.,., 40 :::> :.> : ::.:::. :.::.:;;. ..::::..:. .. . � RA iNC1 iZ N MB R N T $ 4/ ox FAU Colt UNZIR Z/O 4 TON 1 c, RAJ / COUD ISING weir nuez 3 7773 � WA. ST. CONTRACTOR'S LICENSE # EXP. DATE BUILDING USE (office, warehouse, etc.) / NATURE OF BUSINESS:MvszuN/ WILL THERE BE A CHANGE IN USE? El No Q Yes IF YES, EXPLAIN: WILL THERE BA STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? LL1 No 0 Yes IF YES, EXPLAIN: PROPERTY OWNER Mu9Etj or RlbFlt ouNDATIoN PHONE(ZQ6) 7Eq- 5700 ADDRESS ,940 a As7 I1,R&INAL ()Ay SoOrll SEAratt WA ZIP )g1Ug CONTRACTOR ex) NT C.Ul,d R rlin PHONE ADDRESS ZIP WA. ST. CONTRACTOR'S LICENSE # EXP. DATE :.DESCRIPTION AMOUNT : RCPT #: .::DATE::::: BASIC PERMIT ,:$15.00: ..: ....: UNIT(S) > FEE::::;: .; . :.... : PLAN ;CHECK : FEE : ;:: .. OTHER:: . >... :...... :... ....:...... <..... :..'. ::: TOTAL': :.: CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK NUMBER Thq O APPLICATION MUST BE FILLED OUT COMPLETELY XAM IN ................... BUILDING OWNER OR AUTHORIZED AGENT SIGN ,t R CONTACT PERSON >AIC -1/FIzt, BEGKE7.'AIA PRINT NAME R Ich1}R1, Ec1<t= K9ri/v D1ntcrok of Ri atis ADDRESS ,yyrq , As7 AO( QA WAY Spvlll 0 R EA. ro,v DATE APPLICATION ACCEPTED MECHAi(.. CAL PERMIT APPLICATION Mechanical Fee Worksheet must also be filled out and attached to this application. FEES (for staff use only) DATE APPLICATION EXPIRES DATE :.:. PHONE CITY /ZIP S e , ' 'Pos. PHONE (Z06) 76L/ 5700 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. A completed "Mechanical Permit Fee Worksheet" must accompany this permit application. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and Dlans must be complete in order to be accepted for plan review. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in ht the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. if you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 431 -3670. 06/18/OQ DESCRIPTION UNIT COST O UNITS X TOTAL COST BASIC FEE $15.00 $4.50 SUPPLEMENT PERMIT FEE 1 Installation or relocation of each forced -air gravity -type furnace or burner, Including ducts and vents attached to such appliance, up to and including 100,000 Btu /h. $9.00 X 2 Installation or relocation of each forced -air or gravity -type furnace or burner, including ducts and vents attached to such appliance over 100,000 Btu /h. $11.00 x 3 Installation or relocation of each floor furnace, including vent. $9.00 X 4 Installation or relocation of each suspended heater, recessed wall heater or floor- mounted unit heater. $9.00 X 5 Installation, relocation or replacement of each appliance vent installed and not included in an appliance permit. $4.50 X 6 Repair of, alteration of, or addition to each heating appliance, refrigeration unit, cooling unit, absorption unit, or each heating, cooling, absorption, or evaporative cooling system, including installation of controls regulated by this code. $9.00 X 7 Installation or relocation of each boiler or compressor to and including three horsepower, or each absorption system to and including 100,000 Btu /h. $ X 8 Installation or relocation of each boiler or compressor over three horsepower to and including 15 horsepower, or each absorption system over 100,000 Btu /h and including 500,000 Btu /h. $16.50 X 9 Installation or relocation of each boiler or compressor over 15 horsepower to and including 30 horsepower, or each absorption system over 500,000 Btu /h to and including 1,750,000 Btu/h. $22.50 X 10 Installation or relocation of each boiler or compressor over 30 horsepower to and including 50 horsepower, or for each absorption system over 1,000,000 Btu /h to and including 1,750,000 Btu /h. $33.50 x 11 Installation or relocation of each boiler or refrigeration compressor over 50 horsepower, or each absorption system over 1,750,000 Btu /h. $56.00 X 12 Each air - handling unit to and including 10,000 cubic feet per minute, including ducts attached thereto. (NOTE: This fee shall not apply to an air - handling unit which is a portion of a factory- assembled appliance, cooling unit, evaporative cooler or absorption unit for which a permit is required elsewhere in this code.) $6.50 X 13 Each air - handling unit over 10,000 cfm. $11.00 X 14 Each evaporative cooler other than a portable type. $6.50 X 15 Each ventilation fan connected to a single duct. $4.50 X 16 Each ventilation system which is not a portion of any heating or air - conditioning system authorized by a permit. $6.50 X 17 Installation of each hood which is served by mechanical exhaust, including the ducts for such hood. $6.50 X 18 Installation or relocation of each commercial or industrial -type incinerator. $11.00 X 19 Installation or relocation of each commercial or industrial -type incinerator. $45.00 X 20 I Each appliance or piece of equipment regulated by the code but not classed in other appliance categories, or for which no other fee is listed in this code. $6.50 X 00118100 SUBTOTAL PLAN CHECK FEE ( of subtotal) GRAND TOTAL $ CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 THIS WORKSHEET MUST ACCOMPANY YOUR MECHANICAL PERMIT APPLICATION. MECHAN[. ;AL PERMIT FEE WORKSHEET iNS.TRUCTiONS Co mplete the :worksheet, indicating he number of units being i nstalled, in each;category . At time of sub ittal,'staff wi ll calculate the fees. City of Tukwila Project Name 1 (.4.7 (A v\ I (, n f Address 116 4 h` 145t' / 6 %,, . `) Suite # Retain current inspection schedule ,/' Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authori ed 14eature V iNALAPP.FRM FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 Needs shift inspection Gary L. VanDusen, Mayor TURWILA FIRE DEPARTMENT f ` ) , ' • i -x. FINAL APPROVAL FORM ,vr Cxic0 9, 006 / Control No. Permit No. C /_ Date T.F.D. Form F.P. 85 T NY's"" i {nF Plmrs —` "^` * vL�► m� �' �'l � g .;+ plg. - " 't itm rp M, , l.r— * A•******* A-****• h* k* A* * * * ** ** ** ** ** * * * * * * • * * *k * *A* * ** *fir** *` ** * * *9t CITY aF' T WA TR ANSMIT. GENERA 6.00 *******•***************•* r***: '* ** ** **** * * *k ** * * * *kk'h ***** r**** * * **?k*. GENERA. 24.00 MIT Number: :,920 6. 30..00 04/22/92 13:40.. TOTAL`: 30.00 o, Permit, N, M92 0060( ; Ty.pe. �MECH MCCHANIGWL ,PERMIT CHECI( 30.00. P mr ce l =Na a :. "332404 - 90 .9 CHANGE 0.00 Site Addr.esse `'9404 -. EAST MARGINAL WY S 04/22/92 0158A000 :;.x :38 Payment : Methr,d ::CHECK Notatiarse KRAFT lr� ta`,6LE3 ******4!w*** ** ***. ?4* k*. *:* . h***°* , .** * *** *A. * * * 'k ** *A*. * ** *, * ** *fir* **** ** Account Cade , aea0 i p,t;7 an Pit i d PLH.NCHECK -' NONI20 6.00 000./322,'.1.00 MECHANICAL NONREB 24.40: dial (TM,is : Payment): fota1..Fe T.at.al.', A1 Pay.mei�i;.s ':Dal 4rnea :. Address: 9404:EAST MARGINAL WY S Tenant: MUSEUM. OF FLIGHT Type: B -MECH Parcel #: 332404 -9019 CITY OF TUKWILA Permit No: M92 -0060. Status: ISSUED Applied: 03/31/1992 Issued: 04/22/1992 • W. * *'k * * *'k * * * *'k * *'k ** * ***•k** ** k***.**• k**.**********' k*' k * * *'k * ** *'k * * * * *'k * *'k ** * * **'k* Permit Conditions: 1. No, changes wi11 be. made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Electrical permit shall be obt.al.ne.d..,thr ough the Washington; State Division .of ;Lab ,, nd` x . -, ""s d�`�.al l electrical o r.. a�tti c��' Z, u s.t r:fi a s� h work will be inspected s =byfP•th°at agency" 7272,) 3 `All ermits, ��•xkr, ,i,, 4 p insp:e ;� • recpr,�ds, and, approve���,� shall be • maintained ava,llabf at. the job site prior7rto the,; of any con stru ,t .on. Th ese. ,documen.ts a ,e, to (be' ainta ; i;n:e•.d "eve i lib le •t,1 i f�: narr r x in spection approval :is,ra •ag, n�ted:" t �' ° �'• ^" ` rx &, t'3 �! .G I•y t% Gf '� rT} ` J T � � - �'.•` , 4. 'Any exposie'd insul backin mater'i�al shah,) %h F'�iame Spread Rating of'- or_ 4l 'and 's Material shall s ibe ar , id fiCeti l howi ng t he a f:fi re perfo fr o strc 'u ion'- rce • rating'r . • , , ,. 5. All c - t on to, be dpn�e conf�o�r•mance wi tha�ap'pr %r St •• G F 1 i � 1 � , . f� fi, Q� 1 8 ��t.�t plans a d ; require,m'ents Ot.1the Uniform Buildin Code (1 =98 z Ed i s'o;a),'iU. i form ' Mech :a n'ica1 i Go..de•�"(1988 Edition), = :Was'i1,n g torji S t a tj'� g E n e rg ° "' C o. ('19 9y1 , E d i t ip On) -'. ` ,;r: 3 ,'' y; Y �� r1 A / , r o' F „r. r 6. Val �id of�,Permit. The' °••i•ss.ua o : . a te permit or app,roval,,,,of \, p i ai si, spec t i a t i. op s.'a'rt d c o rtnp u t a t,i{on s shall not b e ton-- st ue;d to be .a= permit 'for ,,1, , an f • p r ova • �•, -o• , any vio. • .of J g "� y of t he,.prov,isions of ', t h i - s "• ap p r oval or of 3any other�'� tti,,, j',4 ,, 'ord,i an'c'ewof the., iy,risd�i'ct:don\. • No', p' rm•i�t "" t',p give =• •au t , o'r V 1 o o :r ;ca th p s or s of this: code ma x �,\A . P .. sha beel id. .t'` � � . r= 4 i a f / • ,k " •. r S_ . "�, 3rCs !"'- ',. / .a e% ti • City of Tukwila FIRE DEPARTMENT Fire Department Review Control #M92 -0060 (512) Re: Museum of Flight - 9404 East Marginal Way South Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. units rated at 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1528) Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1528) Call the Tukwila Fire Department at 575 -4404 for approval of any system shut down. Have job site address, name, and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1528) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd April 21, 1992 John W. Rants, Mayor Project—r w• `'�� Type o ns n: c Address: . Date Called: Special Instructions: Date Wanted: '_ ( I --q 2..... am. Requester: Rhone No.: —7 C if , 6 7 0'0 Receipt No.: •/ C. INSPECTION RECORD (.: Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 I Inspector: Dade: 1°- /- y z,- Approved per applicable codes. • ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ❑ Corrections required prior to approval. Date: PERMIT NO. (206) 431 -670 rY COMMENTS: ' N 5ucir Sc- a2.-4. S - r - 1:4,41 — vJ% L L. f". 0 eit-kayl v *.ticiv-mrk 14C, . 0 ts3 'ME -sT At: "E tx-cwiv. S 1 oc- c...4ay.A e +.:el'E - MAE.- - A o CI LE• -. 's es I.3 IC E - fin PS iTE - F - 19.s 1 wort Special Instructions: Date Wanted: • Requester: .--i Project: n ktAia j (.4 o Type of Inspection: g Address: 6, Date Called: Special Instructions: Date Wanted: Requester: .--i Phone No.: Inspector: O INSPECTION RECORD C Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 0 Approved per applicable codes; M Corrections required prior to approval. PERIN NO. (206) 431V3670 Date: 0 O $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No,: Dale: COMMENTS: • t) /ACC•SS 'TO 0) ( Kr .0 Ate t' t J „ vr►, S.S r o n1 CA) JT12d YZ.X3h') IS NOT" 11/4 t,Rfir✓. -') i ' '.1 CA) t-i to tr4.514(::; v, 14 VT'. te a) O *Tk i`rl , -'7Lt CAA— F-t 1,0 — Date Called; ` rr-tti.E 755" ,a€ .tn ( i t tzt-,n eN• Fis L U NIT . .1.1. - .2.a Q cr.:--n . I taCA T ley S tAhl■\ t S 12 tsfr A'+ 2craNcN c--vi.. A NV IS AC rA A - r.A.• o:f friflaG IF " l S,C pt ht �rro C Fi-r- 4 in T rtE 5Tt rc"RoNS, - r 1.1 Sr,,3,v 'ti, ,_.mt=tt rt.. i S 11 env. % te: . � I N r rt l./ Phone No.: ro ect: (A.5- -,tic m d F � r C' Hr ype o nspection: �t iv Al— Address: Date Called; Special Instructions: Date Wanted: �(1 3 , Z a`rp* Requester: � I N r rt l./ Phone No.: .,.+ , Receipt No.: Dale: i DATE J E PIE mi3ER Z r CITY OF TUKWILA 6300 SOUTHCENTER BOULEVARD TUKWILA, WA 98188 s; •,,; REVISION SUBMITTAL PROJECT NAME - f}ALCCAI(,t2 L r�4RNIN6 LI Jr R ADDRESS 9'10 &sr MARGINAL 1dAy So vrl' CONTACT PERSON / eN O N /1''A /'T PHONE 76 Lf 5700 IJES/GArR •ems //VAC ARCHITECT OR ENGINEER G RE& O V ARC II / 'CAS CLyiIA GR 'GO vJ System /s FENro,tl le/MAT PLAN CHECK/PERMIT NUMBER 0.9Z " 0060 (z- Ooh () TYPE OF REVISION: ADP/ TIO oP' VA V 8o,ves To R &WWC EAJ1'RGY Use A/VI) &A 11t) INCRe4S612 CNTRI, OF ZOi Tellpc flJR1s , 'Hovey UNITARY teivrgato 7 RE/)') W /R1N6 C1fl1Ph /Iry kIID /NCPpASR,e1 NVMMeR or tioNi oRed Po/Nn SHEET NUMBER(S) >� 1 "Cloud" or highlight all areas of revisions and date revisions. SUBMITTED TO: CPI p�pvWED DATE itAs/9z_ PERMIT NUMBER (Y PLAN CHECK NUMBER TYPE OF REVISION: $ HIE r Cl- SUBMITTED TO: (If previously issued) CITY OF TUKWILA 6300 SOUTHCENTER BOULEVARD TUKWILA, WA 98188 * * REVISION SUBMITTAL PROJECT NAME Mv5 /rUH d F FL IGHT CNAGLAtl &E4 1EARIVIN6 CENTER ADDRESS CONTACT PERSON MA/ray KRAFT PHONE 76 q - 5700 ARCHITECT OR ENGINEER FtEC 1 I k1�WNA rtly A SHEET NUMBER(S) ' vtlk< I �' P "Cloud" or highlight all areas of revisions and date revisions. C ' . A‘i' polo ctslec‘ Mission Control Quan Description Watts 20 People Lights 444.6 Equipment 3250 Space Station Quan Description Watts MUSEUM OF FLIGHT COOLING LOAD CALCULATION CHALLENGER CENTER PROJECT 20 People 315 325 6300 6500 12800 Lights 444.6 1517 1517 1517 Equipment 4000 13652 13652 13652 Challenger Center Total Quan Description Watts Btu/h Btu/h Btu/h Btu/h Btu/h Sensible Latent Total Total Total per Item per Item Sensible Latent Load 315 325 6300 6500 12800 1517 1517 1517 11092 11092 11092 Mission Control Totals Space Station Totals Sensible Load Latent Load Total Load Total Load Sensible to Total Ratio Air Flow @450 cfm/Ton Discharge Air Temp. Design Condensing Temp. Design Evaporator Temp. i 18910 I 650C 9 Challenger Center Totals Design CFM Btu/h Btu/h Btu/h Btu/h Btu/h Sensible Latent Total Total Total per Item per Item Sensible Latent Load I 21469 6500 27969 1049 Design CFM Btu/h Btu/h Btu/h Btu/h Btu/h Sensible Latent Total Total Total per Item per Item Sensible Latent Load 40 People 315 325 12600 13000 25600 Lights 889.2 3035 3035 3035 Equipment 7250 24744 24744 24744 I .. 13000 533 2002 Design CFM RECEIVED CITY OF TUKWILA MAR 3 1 1992 PERMIT CENTER Btu/h Btu/h Btu/h Tons cfm deg.F deg.F deg.F Mission Control Space Station Quan Description Watts Challenger Center Total MUSEUM OF FLIGHT COOLING LOAD CALCULATION CHALLENGER CENTER PROJECT Mission Control Totals Space Station Totals Sensible Load Latent Load Total Load Total Load Sensible to Total Ratio Air Flow @450 cfm/Ton Discharge Air Temp. Design Condensing Temp. Design Evaporator Temp. RECEIVED r,i v nC TI tie A l n MAR 3 1 1992 PERMIT CENTER Btu /h Btu /h Btu /h Btu /h Btu /h Sensible Latent Total Total Total per Item per Item Sensible Latent Load 20 People 315 325 6300 6500 12800 Lights 444.6 1517 1517 1517 Equipment 3250 11092 11092 11092 18910 f ' 6500 25410 953 Design CFM Quan Description Watts Btu /h Btu /h Btu /h Btu /h Btu /h Sensible Latent Total Total Total per Item per Item Sensible Latent Load 20 People 315 325 6300 6500 12800 Ughts 444.6 1517 1517 1517 Equipment 4000 13652 13652 13652 Challenger Center Totals : :> : 40379 1 21469 : 6500 27969 1049 CFM Quan Description Watts Btu /h Btu /h Btu /h Btu /h Btu /h Sensible Latent Total Total Total per Item per Item Sensible Latent Load 40 People 315 325 12600 13000 25600 Ughts 889.2 3035 3035 3035 Equipment 7250 24744 24744 24744 Design CFM Btu /h Btu /h Btu /h Tons 379 2002 cfm deg.F deg.F deg.F Quan EQUIPMENT SUMMARY Mission Control 4 Front Monitors 1 Nav 1 Med 1 Probe 1 Research 1 Iso 1 Rem 1 LS 1 Com 1 Data 1 Flight Director Space Station 4 Back Wall 1 Back Wall 1 Back Wall 2 Back Wall 1 Mission Commander 1 Mission Commander 1 Mission Commander 1 Probe 1 Probe 1 1 Probe 1 Rem1 1 LS 1 Med 1 Iso 2 Iso 3 Behind Iso 1 Glove Box 26" Monitors Computer Computer Computer Computer Computer + 2 Robots Computer Computer Computer + Amp Computer + Printer Computer 20" Monitors Computer Vidio Disk Player Cassete Players Computer + Printer Audio Mixer Amplifier Video Camera Computer Indicator Lights Computer + Robot Computer Computer Computer + Printer Robots Robots LV Ughts Mission Control Total Space Station Total Watts Watts Btu /h Each Total Total 200 200 200 200 200 400 200 200 350 300 200 120 200 50 75 300 160 250 160 200 250 300 200 200 300 100 100 300 800 200 200 200 200 400 200 200 350 300 200 3250 11092 480 200 ,50 150 300 160 250 160 200 250 300 200 200 300 200 300 300 Total Equipment 7250 24744 RECEIVED CITY OF TUKWILA MAR 3 1 1992 PERMIT CENTER 4000 13652 Quan EQUIPMENT SUMMARY Mission Control 4 Front Monitors 1 Nay 1 Med 1 Probe 1 Research 1 !so 1 Rem 1 LS 1 Com 1 Data 1 Flight Director Space Station 4 Back Wall 1 Back Wall 1 Back Wall 2 Back Wall 1 Mission Commander 1 Mission Commander 1 Mission Commander 1 Probe 1 Probe 1 1 Probe 1 Rem 1 1 LS 1 Med 1 Iso 2 Iso 3 Behind Iso 1 Glove Box 26" Monitors Computer Computer Computer Computer Computer + 2 Robots Computer Computer Computer + Amp Computer + Printer Computer 20" Monitors Computer Vidio Disk Player Cassete Players Computer + Printer Audio Mixer Amplifier Video Camera Computer Indicator Lights Computer + Robot Computer Computer Computer + Printer Robots Robots LV Lights Mission Control Total Space Station Total Watts Watts Btu /h Each Total Total 200 200 200 200 200 400 200 200 350 300 200 120 200 50 75 300 160 250 160 200 250 300 200 200 300 100 100 300 800 200 200 200 200 400 200 200 350 300 200 3250 11092 480 200 50 150 300 160 250 160 200 250 300 200 200 300 200 300 300 RECEIVED CITY OF TIIKWILA MAR 3 1 1992 PERMIT CENTER 4000 13652 Total Equipment 7250 24744 Product Data 38TKB (60 Hz) Air Conditioner Sizes 018 thru 060 FEATURES BENEFITS c2 and hot condenser air up and away ir from adjacent patio areas and foliage. New heat pump style drain pan for easy removal of water, dirt, and leaves. Application Versatility — The • 38TKB can be combined with a wide variety of evaporator coils and blower packages to provide quiet, . dependable comfort. Unit can be installed on a roof or at ground level. External Service Valves — Both service'v are brass type with copper s'Vueaf connections. Valves are extgpOIly', locat4g1, j;o refrigerant tube 44'1Tt 1, * ?t' Model number nomenclature Electric Air Conditioner Nominal Capacity 018 — 18,000 Btu 038 — 36,000 Btu 024 — 24,000 Btu 042 — 42,000 Btu 030 — 30,000 Btu 048 — 48,000 Btu 036 — 36,000 Btu 060 — 60,000 Btu e® 38TKB connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures. Easy Serviceability — One access panel provides access to electrical control box and compressor. Removal of top gives access to fan motor and coil. Reciprocating Compressor Protection — Each model equipped with a reciprocating compressor is protected with internal temperature - and current - sensitive overloads. An internal pressure relief valve provides 018 ' 3 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. Electrical 3 — 208.230 -1 5 — 208-230-3 6 — 460 -3 Series Packaging The data in this publication Is displayed for all series, however every series may not be available from manufacturer. h- pressure protection for the refrigerant system. Scroll Compressor — 048 & 060 size units feature the Copeland® Compliant Scroll' Compressor. The scroll compressor does not require a crankcase heater and will start under most system loads, thus eliminating the need for start assistance components. Continuous operation is approved from 55 F (12.8 C) to 125 F (37.0 C) in the cooling mode. See cooling performance tables. • • • Physical data 17{ REFRIGERANT Control CHARGE (lb) COND FAN Air Discharge Air Qty (cfm) COND COIL Face Area (sq tt) VALVE CON (in. ID) Vapor Liquid REFRIG TUBES' (In. OD) Vapor Liquidt o Weather © High -Eff e Total Se 4.06 NOTE: See unit Installation Instructions for pro *Tube sizes are for runs up to 50 ft. For tube set over 50 ft consult Long -Line Appli T3I8 in. liquid tube must be used on capillary ty , . . * S'jR" ' .+,.. , WI' t.!l'LI . q n_ COAL 1 }X -r �Jt4'[,'0 . y i . k � L i ' " � ' ! i4?Sl7 h � 794. . �I VW REFRIGERANT Control 22 AccuRater" (Bypass Type) CHARGE (lb) 4.06 I 4.38 I 5.25 I 5.38 I 6.38 6.43 I 7.38 I 10.00 COND FAN Air Dischare Air Qty (elm) 1600 I 1900 I 3000 I 2900 COND COIL Face Area (sq tt) 7.2 10,8 15.0 VALVE CON (In. ID) Vapor Liquid 5/8 3/4 3/8 7/8 REFRIG TUBES" (in. OD) Vapor Liquidt 5/8 I 3/4 I 3/8 7/8 I 1 -1/8 and •h.pressure protection for the .)rt refrigerant system. Scroll Compressor — 048 & 060 size units feature the Copeland® Compliant Scroll' Compressor. The scroll compressor does not require a crankcase heater and will start under most system loads, thus eliminating the need for start assistance components. ass ped s Continuous operation is approved re- from 55 F (12.8 C) to 125 F (37.0 C) n in the cooling mode. See cooling des performance tables. N APPLIES ONLY WHEN THE YSTEM IS LISTED WITH ARI. Packaging !able from manufacturer. O Weather Armor" II Cabinet 0 Copper Tube /Aluminum Fin Coll O High - Efficiency Fan Motor 0 Solid Brass Service Valves ® Total Service Access 0 High - Efficiency Compressor A91092 Physical data NOTE: See unit Installation Instructions for proper installation. 'Tube sizes are for runs up to 50 ft. For tube set over 50 ft consult Long -Line Application Guideline. t3/8 in. liquid tube must be used on capillary type coils. 3 ORDERING NUMBER DESCRIPTION 38TH900001 /KAATD0101TDR Indoor Time -Delay Relay (All sizes) 018 -042 38TG900521 Motormaster Controller (All sizes)* (1 -Phase & 3 -Phase 208 -230 volt only) 38TG900531 Motor Master Controller -036, 048 & 060 Sizes (3 -Phase 460 volt only) 38TG900481 Low- Ambient Motor Ball Bearing (Sizes 018 -036) 38TG900511 Low - Ambient Motor Ball Bearing (Sizes 038, 042, 048, 060) KSALA0101 AAA Low - Ambient Controller (All Sizes —All Phases)$ 38TG900561 /KAAWS0101AAA Low- Ambient Winter Start Controlt 024 -060 38TG900551 /KAAFT0101AAA Low - Ambient Evap Freeze Thermostatt 024 -060 38TG900141 Timeguard II (All non - scroll units) 018 -042 38TG900271 /KAACS0201PTC Start Assist -PTC (12.5 Ohms) 018-042 38TG900291 /KAAHS0201AAA Start Assist - Cap /Relay (Sizes 018-31, 024 -31, 030 -31 & 036 -31) 38TG900351 /KAAHS0801AAA Start Assist - Cap /Relay (Sizes 018 -30, 024 -30, 030 -30 & 036 -30) 38TG900311 /KAAHSO401AAA Start Assist- Cap /Relay (Sizes 038-30, 042 -30) 38TG900431/KAACH0401TEC Crankcase Heater (Sizes 018 -31, 024 -31, 030 -31 & 036 -31) 38TG900441 /KAACH0501TEC Crankcase Heater (Size 036-51) 38TG900641 /KAACH0901 TEC Crankcase Heater (Size 036-61) 38TG900401 /KAACH0101COP Crankcase Heater (Sizes 018 -30, 024 -30, 030 -30 & 036 -30) 38TG900411 /KAACH0201CYL Crankcase Heater (Size 036-50) 38TG900421 /KAACH0301CYL Crankcase Heater (Size 036 -60) 38TG900191 /KSASH0201TEC Soundshield (Sizes 030 -31, 036 -31, -51, -61) 38TG900631 /KSASH1301TEC Soundshield (Sizes 018 -31 & 024-31) 38TG900611 /KSASH1101COP Soundshield 018-30 & 024 -30 38TG900621 /KSASH1201COP Soundshield 030 -30, 036-30, -50, -60, 038 -30 & 042-30 38YG900241 /KSASH1701COP Soundshield 048-30 & 060 -30 38YG900011 /KHATX0201RPB TXV Kits (RPB) (Size 018) 38YG900021 /KHATX0301RPB TXV Kits (RPB) (Size 024) 38YG900031 /KHATX0401RPB TXV Kits (RPB) (Size 030) 38YG900041 /KHATX0501RPB TXV Kits (RPB) (Sizes 036 -042) 38YG900051 /KHATX0601RPB TXV Kits (RPB) (Size 048) 38YG900061 /KHATX0701RPB TXV Kits (RPB) (Size 060) 38YG900081 /KHATX0901HSO TXV Kits (Hard Shutoff) (Size 018) 38YG900091 /KHATX1001HSO TXV Kits (Hard Shutoff) (Size 024) 38YG900101 /KHATX1101HSO TXV Kits (Hard Shutoff) (Size 030) 38YG900111 /KHATX1201HSO TXV Kits (Hard Shutoff) (Sizes 036 -042) 38YG900121 /KHATX1301HSO TXV Kits (Hard Shutoff) (Size 048) 38YG900131 /KHATX1401HSO TXV Kits (Hard Shutoff) (Size 060) 38TG900151 /KAAL00101LPS Low Pressure Switch (All sizes) 018 -060 38TG900171 /KSAHI0101HPS High Pressure Switch (All sizes) 018 -060 P502 - 8083S Filter Drier (Size 018) P502 - 8163S Filter Drier (Sizes 024 -060) 38TG900541 /KAALS0101LLS Liquid Line Solenoid Valve 018 -060 38TH900011 /KSASF0101AAA Support Feet Kit 018 -060 * Low - Ambient motor also reoulred on sinale -phase units. Accessories S t Consult Low - Ambient Installation Instructions for application. Use only in combination with accessory Low Pressure Switch. Ball- bearing motor not necessary In this application. 4 THERMOSTAT /SUBBASE PKG. HHO7AT174 HHO7AT184 HH93AZ176 HHO7AT164 HHO7AT191 DESCRIPTION Honeywell— Automatic changeover; One -stage heat /One -stage cool— F All Sizes Honeywell — Manual changeover with subbase; One -stage heat /One -stage cool— F All Sizes Subbase for Auto Thermostat All Sizes Honeywell— Automatic Changeover; One Stage Heat/One Stage Cool— C Honeywell — Manual Changeover With Subbase; One -Stage Heat/One -Stage Cool— C • • • Accessory Description and Usa Y P 1. Indoor Time -Delay Relay A SPST delay relay which briefly continues operatl SUGGESTED USE: For improved efficiency ratings fo 2. Low - Ambient Operation Kit This solid-state head pressure controller is a fan sp speed In response to saturated condensing tempera ture at 100 F ± 10 F (37.8 ± 5 C). For single•phas SUGGESTED USE: Cooling operation at outdoor to All commercial installations. (Not 3. Ball Bearing Fan Motor A fan motor with ball bearings which permits spee SUGGESTED USE: Required on all single-phase units 4. Winter Start Control A SPST delay relay which bypasses the low•pressu SUGGESTED USE: All air conditioners which have lo 5. Evaporator Freeze Thermostat A SPST temperature actuated switch which stops SUGGESTED USE: All units where Low-Ambient Op 6. TimeGuard II — Compressor Short Cycle Prot Solid -state timing device which prevents compres Interrupted for any reason, including normal room SUGGESTED USE: Installations In areas where powe Where user is likely to "play" I.vit All commercial installations. Installations where interconnectin High-rise applications. 7. Compressor Start Assist — PTC Type Solid state electrical device which gives a "soft" b SUGGESTED USE: Installations with marginal power Replacement Installations with ra Replacement Installations with u 8. Compressor Start Assist — Capacitor /Relay Start capacitor and start relay gives "hard" boost SUGGESTED USE: Installations where Interconnect' Installations where outdoor deslg Replacement Installations with h 9. Crankcase Heater An electric resistance heater which mounts to th compressor lubrication on restart and minimizes c SUGGESTED USE: When Interconnecting tube lengt When unit will be operated below All commercial Installations. 10. Sound Blanket/Shield /Hood Wrap-around sound attenuation cover for the co SUGGESTED USE: Unit installed closer than 15 ft to Unit Installed between two house 11. Thermostatic Expansion Valve (TXV) Kits A modulating flow control valve which meters r evaporator. Kit includes valve, adapter tubes and SUGGESTED USE: For Improved system performan 12. Refrigerant Low - Pressure Switch Auto reset SPST switch activated by refrigerant p Prevents Indoor coil freeze-up due to loss of indoo prevent rapid compressor recycling, Compressor SUGGESTED USE: Where Indoor coil is exposed to ' All commercial installations. 13. Refrigerant High - Pressure Switch Auto reset SPST switch activated by refrigerant p Provides additional protection against compress CYCLE PROTECTOR (Item 6) can be used with SUGGESTED USE: Installations exposed to very "di Installations where condenser in 14. Refrigerant Filter Drier A device for removing contaminants from refrige SUGGESTED USE: All field - connected split system a 15. Liquid Line Solenoid (LLS) An electrically operated shut-off valve to be install flow in response to compressor operation. Mainta assist — Capacitor /Relay type — (Item 8) must SUGGESTED USE: For improved system performan In certain long line - applications 16. Support Feet Four stick -on plastic feet which raise the unit 4 I corrosion. SUGGESTED USE: Coastal installations. Windy areas or where debris Is Rooftop installations. TION 3 -230 volt only) 30 volt only) 36 -31) 36 -30) 1) ssory Low Pressure Switch. TION age cool— F All Sizes heat /One -stage cool— F All Sizes Stage Cool— C v Heat/One -Stage Cool— C Accessory Description and Osage 1. Indoor Time -Delay Relay A SPST delay relay which briefly continues operation of the Indoor blower motor to provide additional cooling after the compressor cycles off. SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. (Refer to ARi Unitary Directory) 2. Low - Ambient Operation Kit This solid -state head pressure controller is a fan speed control device activated by a temperature sensor. It is specifically designed to control outdoor fan motor speed In response to saturated condensing temperature. For outdoor air temperatures between 55 and 0 F (12.8 and —17.8 C), it maintains condensing tempera- ture at 100 F ± 10 F (37.8 ± 5 C). For single -phase units a ball bearing fan motor is also required. SUGGESTED USE: Cooling operation at outdoor temperatures below 55 F (12.8 C). All commercial installations. (Note: 3 -phase units have ball bearing fan motors as standard.) 3. Ball Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. SUGGESTED USE: Required on all single -phase units where Motormaster (Item 2) has been added. 4. Winter Start Control A SPST delay relay which bypasses the low- pressure switch for approximately 3 minutes to permit start -up for cooling operation under low load conditions. SUGGESTED USE: All air conditioners which have low- pressure switch and Low - Ambient Operation Kit (Item 2) has been added. '' 5. Evaporator Freeze Thermostat A SPST temperature actuated switch which stops unit operation when evaporator reaches freeze -up conditions. SUGGESTED USE: All units where Low - Ambient Operation Kit (Item 2) has been added. 6. TlmeGuard II — Compressor Short Cycle Protector Solid -state timing device which prevents compressor rapid recycling. Control provides an approximate 5- minute delay after power to the compressor has been interrupted for any reason, including normal room thermostat cycling. SUGGESTED USE: Installations in areas where power interruptions are frequent. Where user is likely to "play" with the room thermostat. All commercial installations. Installations where interconnecting tube length exceeds 50 ft. High -rise applications. 7. Compressor Start Assist — PTC Type Solid state electrical device which gives a "soft" boost to the reciprocating compressor at each start -up. SUGGESTED USE: Installations with marginal power supply. Replacement installations with rapid pressure balance (RPB) expansion valve on indoor coll. Replacement installations with undersized interconnecting refrigerant tubes. 8. Compressor Start Assist — Capacitor /Relay Type Start capacitor and start relay gives "hard" boost to reciprocating compressor motor at each start -up. SUGGESTED USE: Installations where Interconnecting tube length exceeds 50 ft. Installations where outdoor design temperature exceeds 105 F (40.6 C). Replacement installations with hard shut -off expansion valve on indoor coil. 9. Crankcase Heater An electric resistance heater which mounts to the base of the reciprocating compressor to keep the lubricant warm during off cycles. Improves reciprocating compressor lubrication on restart and minimizes chance of refrigerant slugging. Not required in scroll compressor applications. SUGGESTED USE: When interconnecting tube length exceeds 50 ft. When unit will be operated below 55 F (12.8 C) outdoor air temperature. (Use with Low - Ambient Operation Kit Item 2.) All commercial installations. 10. Sound Blanket/Shield /Hood Wrap - around sound attenuation cover for the compressor. Reduces the sound level by about 0.2 bels. SUGGESTED USE: Unit installed closer than 15 ft to quiet areas — bedrooms, etc. Unit installed between two houses less than 10 ft apart. 11. Thermostatic Expansion Valve (TXV) Kits A modulating flow control valve which meters refrigerant liquid flow rate Into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit Includes valve, adapter tubes and external equalizer tube. Both hard shut -off and RPB type valves are available. SUGGESTED USE: For improved system performance In cooling mode for certain combinations of indoor and outdoor units. (Refer to ARI Unitary Directory.) 12. Refrigerant Low - Pressure Switch Auto reset SPST switch activated by refrigerant pressure on low side of refrigerant circuit. Cycles compressor off If refrigerant pressure drops to about 27 psig. Prevents indoor coil freeze -up due to loss of Indoor air flow. Also, provides additional protection against compressor damage due to loss of refrigerant charge. To prevent rapid compressor recycling, Compressor Short Cycle Protector (Item 6) can be used with this switch. SUGGESTED USE: Where Indoor coil is exposed to "dirty" air. All commercial installations. 13. Refrigerant High - Pressure Switch Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to about 425 prig. Provides additional protection against compressor damage due to loss of outdoor air flow. To prevent rapid compressor recycling, COMPRESSOR SHORT CYCLE PROTECTOR (Item 6) can be used with this switch. SUGGESTED USE: Installations exposed to very "dirty" outdoor air. Installations where condenser inlet air temperature exceeds 125 F (51.7 C). 14. Refrigerant Filter Drier A device for removing contaminants from refrigerant circulating in an air conditioner; one - direction flow for air conditioners. SUGGESTED USE: All field- connected split system air conditioners. 15. Liquid Line Solenoid (LLS) An electrically operated shut -off valve to be installed at the outdoor or indoor unit (depending on tubing configuration) and which stops and starts refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle. NOTE: Compressor start assist — Capacitor /Relay type — (Item 8) must also be used, if the system contains a reciprocating compressor. SUGGESTED USE: For improved system performance In air conditioners for certain combinations of Indoor and outdoor units (Refer to ARI Unitary Directory). In certain long line - applications (refer to Long -Line Application Guideline). 16. Support Feet Four stick -on plastic feet which raise the unit 4 In. above the mounting pad. This allows sand, dirt and other debris to be flushed from the unit base; minimizes corrosion. SUGGESTED USE: Coastal installations. Windy areas or where debris is normally circulating. Rooftop Installations. 5 UNIT M OPERATING WT. A B C D E F R LB Kg In. (mm) In. (mm) In. (mm) In. (mm) In. (mm) In. (mm) 4811010114 0 130 62.7 21.718 555.6 22.112 571.5 27.112 698,5 2.13/16 71.4 6-15/16 176.1 13-3/8 339.7 (3111IMIR)20.0 140 63.6 21 -7/8 555.6 22.1/2 571.5 27 -1/2 698.5 2-13/16 71,4 6-15/16 176.1 13-3/8 339.7 !TKS03.OG.0 158 71.8 31 -7/8 809.6 22-1/2 571.5 27 -1/2 698.5 2-13/16 71.4 6 -15/16 176,1 21.1/2 546.1 '3101(4038_ 0 149 67.7 31 -7/8 809.6 22.1/2 571.5 27-1/2 698.5 2-13/16 71.4 6.15/16 176,1 21.1/2 21-1/2 546.1 546.1 3811(.1303114 0 230 104.5 31.7/8 809.6 30 762.0 34.15/16 886.6 4 101.6 9-3/4 247.8 12-13/16 0 230 104.5 31-7/8 809.6 30 762.0 34 -15/16 886.6 4 101.6 9-3/4 247.6 21 -1/2 546.1 1 I3eTKRD4Z? ;.taIT " 0 239 108.6 31 -7/8 809.6 30 762.0 34 -15/16 886.6 4 101.6 9-3/4 247.8 21-1/2 546.1 k:3111 4(18e * 0 255 115.9 31-7/8 809.6 30 762.0 34.15/16 886.6 4 101.6 9.3/4 247.6 21-1/2 546.1 � t asTK*O14§ 1 143 65.0 21-7/8 555.6 22.1/2 571.5 27 -1/2 698.5 2-13/16 71.4 6.15/16 178.1 13.3/8 339.7 alTK34 1 153 69.5 21 -7/8 555.6 22-1/2 571.5 27-1/2 698.5 2-13/16 71.4 6-15/16 176,1 13-3/8 339.7 ��3aTKKp3�0% 1 163 74.1 31 -7 /8 809,6 22.1/2 571.5 27 -1/2 698.5 2.13/16 71.4 6-15/16 176,1 21 -1/2 546.1 ;`3lTKIID3D0 1 168 76.4 31-7/8 809.6 22.1/2 571.5 27.1/2 698.5 2.13/16 71.4 6 -15/16 176,1 21-1/2 548.1 UNIT M G H J K L M yl In. (mm) In. (mm) In. (mm) In. (mm) In. (mm) In. (mm) t38TKS019`:f 0 17-7/8 454.0 5/8 15.88 2-3/8 60.3 12 -3/16 310 14.1/2 368 10.3/8 264 ;3101(8024 0 17 -7/8 454.0 5/8 15.88 2-3/8 60.3 12-3/16 310 14-1/2 368 10.3 /8 264 130 1(5030 0 27.718 708.0 3/4 19.05 2.318 _ 60.3 12.3/16 310 14-3/4 375 11-13/16 300 '3$TKUO3S` 0 27-7/8 708,0 3/4 19.05 2 -3/8 80.3 12.3/16 310 14-3/4 375 11.13/16 300 „3oTKKDa16` 27 -7/8 708.0 7/8 22.22 2-15/16 74.5 15 -3/4 400 19 483 12.13/16 325 £31rTKK04an 0 27 -718 708,0 7/6 22.22 2 -15116 74.5 15-3/4 400 19 483 12-13/16 325 410X150411_ 0 27.7/6 708.0 7/8 22.22 2-15/16 74.5 13 -1 /2 343 20 -7/16 519 14.1/16 357 r;3$TK� 0 27 -7/8 708.0 7/8 22.22 2 -15/16 74.5 15-3/4 400 19-15/16 508 14-1/16 357 t3STAIKI181 1 17.718 454.0 518 15.88 2 -3/8 60.3 12 305 15-1/8 384 10 -3/8 264 V31111(110114Y( 1 17 -7/8 _ 454.0 5/8 15.88 2 -3/8 60.3 12 305 15-1/8 304 10.3/8 264 t om� , te r-- TKKM3U r 1 27-7/8 708.0 3/4 19.05 2-3/8 60,3 12-9/16 319 14 356 12.5/16 313 1 27.7/8 708.0 3/4 19.05 2 -3/8 60.3 12-9/16 319 14 356 12-5/16 313 Dimensions 6 E -- L 116 0150NIR60 AIR IN -� AIR DISCHARGE AIR IN AI IN C AIA DISCNARGE a R ;39 J/A'O1 4,19.531 LIOUID LINE CONI. (106 /3) FIE))) POWER SUPPLY CON). 7/8 0.172.221 440.E NII)) 1 1 /8' 0.128.57) ANOCROUI 1111,L 51010) -44411 1 3/0 0.134.921 RNOCR0VI 1036 1N)U 060 SIZES 0)4.11 / FIELD CONTROL SUPPLY COMM. / 7/8' D.127.22) 110.E / /N DIA. SUCTION LINE CONN. 10 /2' (266.7) 1 3/4' - - 1 1/4'1 144,67 132.01 N01E5, 1, ALLOY 30 1762) CLEARANCE 10 SERVICE END OF 17111, 49' 11219.2) ABOVE 14411. 6' ((52.4) on ONE 510E, 17' (304.01 DN REMAINING 510E, ANU 24' 1609,6) HEIWEEN ONI15 000 PROPER AIRFLOW, 2. MINIMUM OUTDOOR OPERATING AMBIENT IM COOLING MODE IS 55'0 (12.8'C) (UNLESS LOW AMBIENT CONTROL IS USED) MAX. 125°F )5(,7'C). 3. DIME11510115 IN PARENTHESIS ARE IN MILLIMEICRS, 4. SERIES 0E51004110N 15 Ilf- 13IM POSITION OF THE UNI) MODEL NUMBER. 5. CENTER OF GRAVITY®• 3/8'0.19.531 11E00W6 11.0000013 (2) PLACES UNIT MOUNTI PA TTERN VIEW FROM TOP A91094 • 0 0 • Electrical data • OUTDOOR i Y'UNITl8TK8 :', gY ¢:`,5:024 Rj,7 7 ?038';? ,.. 16048;. z ; err 'r 1 V /PH 208 -230 1¢ 208 -230 30 460 30' OPER VOLTS` MAX. 253 253 506 MIN 197 197 414 FLA - Full Load Amps HACR - Heating, Air Conditioning, Refrigeratio LRA - Locked Rotor Amps MCA - Minimum Circuit Amps ALA - Rated Load Amps ® Preliminary data for 036 -3 Phase VIC • 04 *Piston list nation. Pi approved "'f 1 4�k 4 :� O rittOR *; ,.1 z V /PH OPER VOLTS . COMPR FAN FLA MCA 80° MIN WIRE SIZE 75' MIN WIRE SIZE 60' MAX LENGTH (Ft)$ 75° MAX LENGTH (Ft)$ MAX. FUSEt OR HACR TYPE CKT BKR AMPS MAX. MIN LRA RLA 1 '` 018A ' ` 49.0 8.6 0.5 11.3 14 14 70 66 15 • �a ri O24 1: s 2 61.0 11.2 0.5 14.5 14 14 54 52 20 030k }?;i 75.0 13.7 0.8 17.9 14 14 44 42 25 j a = 208 -230 253 197 86.0 15.3 0.8 19.9 14 14 39 37 30 000.3,575 10 105.0 17.0 1.4 22.7 12 12 55 52 35 t?,,fi'' 't04Z?lOW 105.0 17.3 1.4 23.5 12 12 53 51 40 Fatt4,04ea« % 129.0 23.7 1.4 31.0 8 10 97 61 50 0000W j` 169.0 28.8 1.4 37.4 8 8 83 79 60 X036 at ra , , , rN . .,21147somurge maim .sJZ., ' t5 ami ctIMITTI r . ° ;r . 04j 208 -230 253 197 99.0 13.5 1.6 18.5 14 14 42 40 30 00000M g '.; 30 123.0 17.3 1.6 23.2 12 12 95 56 35 3'�5/ Ci f 3) ; 4 O.k. . i ; iaf . 0 �' � JJ �Ji :�iw'����� '% ) 4V x� i�.U:.� Ic{• E`,, �t[��{tf{t,I� n�'Iw3Y[3C•N�S.�i 1 , YI•., r u �Fi1.iL. r m 1 J �x �d- G � ��t�.�T, !t!r l t��'•Y: • it °' I' 1• J..:.r:':i.: t 409400A 460 506 414 49.5 7.4 0.8 10.0 14 14 79 75 15 Wows" 30 62.0 9.0 0.8 12.0 14 14 66 62 20 49 0219.2) ABOVE MIT. 510F. AM) 71' 1b09.61 OCtMCFN )OE IS SS t12.0 (UNLESS LOM AHDICN) CONTROL IS USED) UNIT HOOEL NUMBER. E !'OW4 I:Iq(f W15 PL.CE5 UNIT MOUNTING PATTERN VIEW FROM 10P A91094 n. 3116 3/16 3/16 3116 4 4 4 13/16 13/16 13/16 3/16 0 (mm) 310 310 310 310 400 400 343 400 305 305 319 319 (mm) 71.4 71.4 71.4 71.4 101.6 101.6 101,6 101.8 71.4 71.4 71.4 71.4 E In. 6-15/16 6.15/16 6.15/18 6.15/16 9.3/4 9.3/4 9 -3/4 9.3/4 6-15/16 6-15/16 6.15/16 In. 368 14.1/2 368 14-1/2 375 14-3/4 375 14-3/4 483 19 483 19 519 20.7/16 506 19-15/16 15.1 /8 15-1/8 14 14 6 -15/16 L (mm) 176.1 178.1 176,1 176.1 247.6 247.6 247.6 247.6 176.1 176.1 176.1 384 384 356 356 176.1 (mm) In. 13 -3/8 13.3/8 21.1/2 21 -1/2 21 -1/2 . 21 -1/2 21-1/2 21 -1 /2 13.3/8 13-3/8 21 -1/2 21 -1/2 10.318 10-3/8 12-5/16 12.5/16 M F In. 10-3/8 10 -3/8 11-13/16 11-13/16 12.13/16 12 -13/16 14-1/16 14 -1/18 (mm) 339.7 339.7 546.1 546.1 546.1 546.1 546.1 546.1 339.7 339.7 548.1 546.1 (mm) 284 264 300 300 325 325 357 357 S 264 264 313 313 c Electrical data FLA - Full Load Amps HACR - Heating, Air Conditioning, Refrigeration LRA - Locked Rotor Amps MCA - Minimum Circuit Amps RLA - Rated Load Amps EMI Preliminary data for 036 -3 Phase 11 ACCURATER® CHART PISTON* IDENTIFICATION NO. * Piston listed is for any approved non - capillary tube non -TXV coil combi- nation. Piston is shipped with outdoor unit and must be Installed in an approved indoor coil. * Permissible limits o the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure. t Time -delay fuse. $ Length shown is as measured one way along wire path between unit and service panel for a voltage drop not to exceed 2 percent. NOTE: 1. Copper wire must be used from service disconnect to unit. 2.The ampacity of non - metallic (NM) sheathed cable shall be that of 60 C (140 F) conductors per NEC 1990, article 336-26. If wire used is not as speci- fied in chart, refer to applicable tables available in 1990 NEC. 7 OUTDOOR MODEL INDOOR INDOOR SECTION AIR CFM TOT CAP BTUH SEAS. EFF. W/TDR. g0t SEER SEAS. EFF. W/0 TDR. 90t SEER EER SOUND RATING SOUND RATING ACCESSORY SOUND BLANKET (BELS) *CC5A/CD5AA018 550 17,200 10.20 10.00 CC5A /CD5AA024 550 17,600 10.50 10.00 CA5A /CB5AA018 550 17,000 10.20 10.00 CA5A /CB5AA024 550 17,300 10.50 10.00 CD3AA018 600 17,000 10.20 10.00 CD3AA024 550 17,600 10.50 10.00 CE3AA024 550 17,800 10.50 10.00 CF5AA024 550 17,800 10.50 10.00 FB(5,4)AN(A,F)018 550 16,800 - 10.00 FB(5,4)AN(A,F)024 550 17,600 - 10.50 FD3ANA018 550 17,100 10.00 - FD3ANA024 550 17,600 10.50 10.00 FF 1 ANA018 550 17,000 10.50 10.00 FF1 ANA024 550 17,600 10.50 10.00 FG3AAA024 550 17,500 10.20 10.00 FK4ANF002 550 18,000 - 12.00 018-30,31 28RDS /RNS018 550 16,500 10.00 9.70 N- N- 28RDS /RNS019 550 17,200 10.50 10.10 28RDS /RNS024 550 17,200 10.50 10.10 40D0S018 550 16,200 9.70 9.50 40DOS024 550 16,900 10.20 10.00 40RC018 600 17,200 10.50 10.30 40RCO24 550 17,000 10.00 9.70 28RH018 550 16,500 10.00 9.70 28RH024 550 17,200 10.50 10.10 28SLS024 550 16,800 10.20 10.00 28RMO24 550 17,100 10.50 10.10 40LT024 550 17,200 10.50 10.10 40YR /YR(F,U,G)018 550 16,900 10.20 10.00 40YR /YR(F,U,G)024 550 17,400 10.30 10.20 40YA/YAF018 550 17,400 - 10.50 40YA/YAF024 550 17,900 - 10.50 40YZ002 550 18,000 - 12.00 *CC5A /CD5AA024 800 22,400 10.20 10.00 " (c!CDCD. cc? CR CP cc! (D.CDCDCP CP cc! 0 . 07 1 up. (LI cc! CD CPCP CD 0 . CDCDCDCD. cc: CDCD( CD. CP CDCo nN-N-r nN NNNNs n is- nnnnrnNNN-NNNPPN- N- nr -N- Ns ne`N- PN-N N- CC5A /CD5AA030 800 22,400 10.20 10.00 CC5A /CD5AW030 800 22,400 10.20 10.00 CA5A /CB5AA024 800 22,000 10.20 10.00 - CB5AA030 800 22,000 10.50 10.00 - CA5A/CB5AW030 800 22,000 10.50 10.00 - CD3AA024 800 22,200 10.20 10.00 - CD3AA030 800 22,400 10.20 10.00 - CE3AA024 800 22,400 10.20 10.00 - CE3AA030 800 22,600 10.50 10.00 - CF5AA024 800 22,200 10.20 10.00 - FB(5,4)AN(A,F)024 800 22,200 - 10.00 - FB5AN(A,F)030 850 22,200 - 10.00 - FB4A(A,F)030 850 23,000 - 10.20 - FD'3ANA024 800 21,600 10.00 - - FD3ANA030 800 22,400 10.00 - - FF1ANA024 800 22,200 10.00 - - FF1ANA030 800 22,400 10.00 - - FG3ANA024 800 21,400 10.00 - 024.30,31 FK4ANF002 800 22,800 - 11.50 - o {ao 28RDS /RNS024 800 21,400 10.00 9.70 - 28RDS /RNS025 800 21,800 10.10 9.80 - 28RDS /RNS030 800 22,400 10.30 10.00 - 28RDS /RNS130 800 22,400 10.30 10.00 - 28RH024 800 21,400 10.00 9.70 - 28RH030 800 22,400 10.20 10.00 - 40RCO24 800 21,000 9.85 9.50 - 40RCO30 800 21,600 9.85 9.50 - 28RMO24 800 21,200 10.00 9.70 - 28SLS024 800 21,000 10.00 9.60 - 28SLS030 800 21,600 10.00 9.80 - 400OS024 800 21,000 10.00 9.70 - 40DOS030 800 21,800 9.90 9.50 - 40LT024 800 21,200 10.00 9.70 - 40YR /YR(F,U,G)024 800 21,400 9.90 9.50 - 40YR /YR(F,U,G)030 800 22,400 10.00 9.80 - 4OYA/YAFO24 800 22,200 - 10.10 - 40YA/YAF030 800 22,600 - 10.50 - 40YZ002 800 22,800 - 11.50 - • • • OUTDOOR MODEL 030 -30,31 036 -30,31 See notes on pg. 11. 'Tested Combination INDOOR SECTION *CC5A /CD5AA030 CC5A /CD5AW030 CC5A /CD5AA036 CD5AW036 CB5AA030 CA5A /CB5AW030 CA5A /CB5AA036 CB5AW036 CD3AA030 CD3AA036 CE3AA030 CE3AA036 CF5AA036 FB5AN(A,F)030 FB4AN(A,F)030 FB(5,4)AN(A,F)036 FD3ANA030 FF1ANA030 FG3AAA036 FK4ANF002 28RDS /RNS030 28RDS /RNS130 28RDS /RNS036 28RDS136 4000S030 40RCO30 28RH030 28RH036 28RM036 28SLS030 28SLS036 40LT036 40YR /YR(F,U,G)030 40YR /YR(F,U,G)036 40YA /YAF030 40YA /YAF036 40YZ002 *CC5A /CD5AA036 CD5AW036 CC5A /CD5AA042 CC5A /CD5AW042 CC5A /CD5AA043 CC5A /CD5AW043 CA5A /CB5AA036 CB5AW036 CA5A /CB5AA042 CA5A /CB5AW042 CD3AA036 CD3AA042 CE3AA036 CE3AA042 CF5AA036 FB(5,4)AN(A,F)036 FB5AN(A,F)042 FB4AN(A,M,F)042 FG3AA036 FK4ANF003 28RDS /RNS036 28RDS136 28RDS /RNS142 28RDS /RNS24201 28RDS /RNSO4301 28RDS /RNS143 28RH036 28RH042 28RM036 28SLS036 28SLSO42 40LT036 40YR /YR(F,U,G)036 40YR/YR(A,U,F,G,M)042 40YA /YAF036 40YA/YF042 40YZ003 INDOOR CFM 900 900 900 900 900 900 900 900 900 900 900 900 900 1000 1000 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 950 900 950 900 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1100 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1065 t Performance data 8 See notes on pg. 11. 'Tested Combination • • Performance data OUTDOOR MODEL INDOOR SECTION INDOOR AIR CFM TOT CAP BTUH SEAS. EFF. W /TDR. 90f SEER SEAS. EFF. W/O TDR. 901 SEER EER 3 -ph SOUND RATING (BELS) SOUND RATING W /ACCESSORY SOUND BLANKET (BELS) *C 28,000 10.20 10.00 - CC 27,800 10.20 10.00 -- C( 29,000 10.50 10.00 - CD5AW036 900 29,000 10.50 10.00 - 27,600 10.20 10.00 - C/ 27,600 10.20 10.00 - C/ 28,800 10.50 10.00 - 28,800 10.50 10.00 - 27,800 10.20 10.00 - CD3AA036 900 29,000 10.50 10.00 - 27,800 10.30 10.00 - 28,600 10.50 10.00 - 28,800 10.50 10.00 - F 27,600 - 10,00 - F 28,400 - 10.30 - FB 28,200 - 10.00 - 27,800 10.00 - - FF1ANA030 900 28,000 10.10 10.00 - 030 -30,31 FG3AAA036 900 28,000 10.50 10.00 - 0 m CO NZ 28,200 - 11.00 - 2 27,600 10.02 10.00 - 2 27,600 10.20 10.00 - 2 900 28,200 28,000 10.20 10.50 10.00 10.10 - 28RDS136 - 40DQS030 900 900 900 900 900 900 28,000 27,000 9.90 9,85 10.20 10.50 10.00 10.00 9.60 9.55 10.00 10.10 9.90 9.80 - 4ORCO30 - 28RH030 - 28RH036 - 28RM036 - 28SLS030 - 28SLS036 900 900 27,400 10.20 10.20 10.00 10.00 - - 40LT036 401 401 27,400 27,600 10.20 10.10 10.00 9.90 - - 40YA/YAF030 900 950 900 - - - 10.20 10.50 11.00 - 40YA/YAF036 - - 40YZ002 'C__...___....___ 1200 33,400 10.20 10.00 9.20 CD CD CD CD CO CD CD CD CDCD cc? CDCD up. CDCDCOC DC DC D( DC DCDCDCDCDCDCOCDCDCDCDCDCDCDCDCD nnt- N. nN. r. N. r: nr. rir. nNN-N NN. N. nNNN- N.NN-N-N CD5AW036 1200 33,400 10.20 10.00 9.10 CC5A /CD5AA042 1200 33,400 10.20 10.00 9.10 CC5A /CD5AW042 1200 33,000 10.20 10.00 9.10 CC5A /CD5AA043 1200 33,200 10.20 10.00 9.05 CC5A /CD5AW043 1200 33,200 10.20 10.00 9.05 CA5A /CB5AA036 1200 33,400 10.20 10.00 9.10 CB5AW036 1200 33,400 10.20 10.00 9,10 CA5A /CB5AA042 1200 33,400 10.20 10.00 9.10 CA5A /CB5AW042 1200 33,000 10.20 10.00 9.10 CD3AA036 1200 33,400 10.20 10.00 9.10 CD3AA042 1200 33,400 10.20 10.00 9.10 CE3AA036 1200 33,000 10.20 10.00 9.05 CE3AA042 1200 33,200 10.20 10.00 9.05 CF5AA036 1200 33,200 10.20 10.00 9.10 FB(5,4)AN(A,F)036 1100 32,400 - 10.00 8.90 FB5AN(A,F)042 1200 33,400 - 10.00 8.95 FB4AN(A,M,F)042 1200 33,400 - 10.00 8.90 036 -30,31 FG3AA036 1200 32,200 10.00 - 8,90 0 03 FK4ANF003 1200 33,000 - 11.00 9.75 28RDS /RNS036 1200 32,000 10.00 9.90 8.90 28RDS136 1200 32,000 10.00 9.90 8.90 28RDS /RNS142 1200 31,600 10.00 9.80 8.80 28RDS /RNS24201 1200 32,600 10.00 10.00 9.00 28RDS /RNSO4301 1200 33,200 10.10 10.00 8.95 28RDS /RNS143 1200 33,200 10.10 10.00 8.95 28RH036 1200 32,000 10.00 9.90 8.90 28RH042 1200 31,800 10.00 9.80 8.80 28RM036 1200 30,800 9.80 9.70 8.70 28SLS036 1200 31,400 9.90 9.80 8.80 28SLSO42 1200 32,200 10.00 9.90 8.90 40LT036 1200 31,800 10.00 9.80 8,80 40YR /YR(F,U,G)036 1200 31,000 9.70 9.50 8.50 40YR /YR(A,U,F,G,M)042 1200 32,400 10.00 9.90 8.90 40YA/YAF036 1200 32,800 - 10.10 8.95 40YA/YF042 1200 33,800 - 10.20 9.05 40YZ003 1065 33,000 - 11.00 - AS. EFF. TOR. 90t SEER 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.50 10.00 10.00 10.00 10.00 12.00 9.70 10.10 10.10 9.50 10.00 10.30 9.70 9.70 10.10 10.00 10.10 10.10 10.00 10,20 10.50 10.50 12.00 10.00 10,00 10.00 10.00 10,00 10,00 10.00 10.00 10.00 10.00 10,00 10.00 10.00 10.20 11.50 9.70 9.80 10.00 10.00 9.70 10.00 9.50 9.50 9.70 9.60 9.80 9.70 9.50 9.70 9.50 9.80 10.10 10.50 11.50 EER 3 -ph SOUND RATING (BELS) 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 8.0 8.0 8.0 8.0 8,0 8.0 8.0 8.0 8.0 8.0 8,0 8.0 8,0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 SOUND RATING W /ACCESSORY SOUND BLANKET (BELS) 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7,6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.8 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7,6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 S Performance data continued See notes on pg. 11. 'Tested Combination 9 OUTDOOR MODEL INDOOR SECTION INDOOR AIR CFM TOT CAP BTUH SEAS. EFF. W/TDR. 90t SEER SEAS. EFF. W/O TDR. 90t SEER EER SOUND RATING OUND RATING / /ACCESSORY SOUND BLANKET (BELS) 080.30 *CC5A 1350 35,600 10.50 10.10 CC5A 1200 35,400 10.50 10.10 CD5AW036 1200 35,400 10.50 10.10 CC5A/CD5AW042 1350 35,400 10.30 10.00 CC5A 1350 35,600 10.50 10.10 CC5A/CD5AW043 1350 35,600 10.50 10.10 CASH 1200 36,000 10.20 10.00 CB5AW036 1200 36,000 10.20 10.00 CA5A 1350 36,400 10.20 10.00 CA5A/CB5AW042 1350 35,600 10.20 10.00 CD3AA036 1200 35,400 10.50 10.10 CD3AA042 1350 35,600 10.50 10.10 CE3AA036 1200 35,000 10.30 10.00 CE3AA042 1350 36,000 10.50 10.10 CHAA036 1300 35,400 10.50 10.00 FB(5,4 )AN(A,F)036 1350 35,000 - 10.00 F85/ 1350 36,000 - 10.20 FB4AN(A,M,F)042 1350 36,000 - 10.20 FG3AAA036 1350 35,600 10.30 10.00 038 -30/31 FK4ANF003 1065 35,600 - 11.00 O cci O CO *CD5AA042 1350 35,600 10.50 10.10 28RC 1200 35,400 10.30 10.00 28RDS136 1200 35,400 10.30 10.00 28R1 1350 35,400 10.20 9,90 28RD; 1350 35,600 10.40 10.10 28RD; 1350 35,600 10.50 10.10 28RD: 1350 35,600 10.50 10.10 28RDSO49 1350 35,600 10.50 10.20 28RH036 1200 35,400 10.30 10.00 28RH042 1350 35,200 10.20 10.00 28RM036 1300 34,400 10.00 9.80 28SLS036 1350 34,800 10.10 9.90 28SLSO42 1350 35,600 10.20 10.00 40LT036 1300 35,200 10.20 10.00 40YR /YR(F,U,G)036 1300 34,600 9.70 9.50 40YR /YR(A,U,F,G,M)042 1350 35,600 10.20 10.00 40YA /YA( )036 1300 35,600 - 10.30 40YA /YA(F)042 1350 35,600 - 10.50 40YZM003 1065 35,600 - 11.00 *CC5A /CD5AA042 1375 40,000 10.50 10.20 0000000000000000000000000000000000000 mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmm CC5A /CD5AW042 1400 40,000 10.50 10.00 - CC5A/CD5AA043 1400 40,000 10.50 10.00 - CC5A /CD5AW043 1400 40,000 10.50 10.00 - CD5AA048 1400 40,000 10.50 10.00 - CC5A/CD5AC048 1400 40,000 10.50 10.00 - CC5A/CD5AW048 1400 40,000 10.50 10.00 - CA5A/CB5AA042 1375 40,500 10.20 10.00 - CA5A/CB5AW042 1400 40,500 10.20 10.00 - CB5AA048 1400 40,500 10.50 10.00 - CB5AC048 1400 38,500 10.20 10.00 - CA5A/CB5AW048 1400 40,500 10.20 10.00 - CD3AA042 1375 40,000 10.50 10.00 - CD3AA048 1400 40,000 10.50 10.00 - CE3AA042 1400 40,000 10.50 10.00 - CE3AA048 1400 40,500 10.50 10.00 - CF5AA048 1400 41,000 10.50 10.00 - FB5AN(A,F)042 1400 40,000 - 10.00 - 042.30 FB4AN(A,M,F)042 1400 40,000 - 10,00 - ! a im FB5AN(A,F)048 1400 41,000 - 10.50 - FB4AN(A,M,F)048 1400 41,000 - 10.50 - FG3AAA048 1400 40,000 10,50 10.00 - FK4ANFOO4 1255 41,000 - 11.00 - 28RDS /RNS142 1375 37,800 10.10 10,00 - 28RDS /RNS24201 1375 39,000 10.20 10.00 - 28RDS /RNSO4301 1375 40,000 10.50 10.10 - 28RDS /RNS143 1375 39,500 10.50 10.10 - 28RDSO49 1375 40,000 10.50 10.20 - 28RDS /RNS148 1375 39,000 10.20 10.00 - 28RDS /RNS248 1375 39,500 10.50 10.10 - 28RH042 1375 38,000 10.10 10.00 - 28RH048 1375 39,000 10.20 10.00 - 28RM048 1375 39,000 10,20 10,00 - 28SLSO42 1375 38,000 10.10 10.00 - 28SLSO49 1375 40,000 10.50 10.20 - 40LT048 1375 39,000 10.30 10.00 - 4OYR /YR(A,U,F,G,M)042 1375 38,500 10.10 10.00 - OUTDOOR MODEL INDOOR SECTION INDOO CF 042 -30 40YR /YR(A,U,F,G,M)048 40YA /YAF042 40YA /YAF048 40YZM004 048 -30 *CD5AA048 CC5A /CD5AC048 CC5A /CD5AW048 CC5A/CD5AA060 CC5A /CD5AW060 CB5AA048 CB5AC048 CA5A /CB5AW048 CA5A /CB5AA060 CA5A /CB5AW060 CD3AA048 CD3AA060 CE3AA048 CE3AA060 CF5AA048 FB5AN(A,F)048 FB4AN(A,M,F)048 FB5AN(A,F)060 FB4AN(A,M,F)060 FG3AAA048 FG3AAA060 FK4ANF005 28RDS /RNS148 28RDS /RNS248 28RDS /RNS057 28RDS /RNS061 28RH048 28RH060 28RM048 28SLSO49 28SLS061 40LT048 40LT060 40YR /YR(A,U,F,G,M)048 40YR /YR(U,F,G,M)060 40YA /YAF048 40YA /YAF060 40YZM005 40YZM006 1 080.30 "CC5A /CD5AW060 CC5A /CD5AA060 CA5A /CB5AA060 CA5A /CB5AW060 CD3AA060 CE3AA060 FB5AN(A,F)060 FB4AN(A,M,F)060 FB4AN(M,F)070 FG3AAA060 FK4ANF006 28RDS /RNS057 28RDS /RNS061 28RH060 28SLS061 40LT060 40YR /YR(U,M,F,G)060 40YA /YAF060 40YZM006 Performance data continued See notes on pg. 11. *Tested Combination 10 • a• ' • Performance dat tSee TDR Table *Tested Combination NOTES: 1. Ratings are net values reflecting 2. Tested outdoor /indoor combinatio other combinations are determine 3. Determine actual cfm values obta 4. The dashes ( -) appearing in the hard shut-off TXV (40YA, 40YZ a OUTDOOR MODEL INDOOR SECTION INDOOR AIR CFM TOT CAP BTUH SEAS. EFF. W /TDR. 90t SEER SEAS. EFF. W/O TDR. 90t SEER EER 3 -ph SOUND RATING (BELS) SOUND RATING W /ACCESSORY SOUND BLANKET (BELS) 4 5 39,500 10.50 10.10 - 8.0 8.0 042 -30 5 5 41,000 41,500 - - 10.50 10.50 - - 8.0 8.0 8.0 8.0 5 41,000 - 11.00 - 8.0 8.0 0 46,500 10.50 10.30 9.25 0 46,500 10.50 10.30 9.10 0 46,500 10.50 10.30 9.15 0 47,000 10.50 10.30 9.15 0 48,000 10.70 10.50 9.30 0 47,500 10.20 10,00 9.00 0 45,500 10.50 10.30 9.15 0 47,500 10.20 10.00 9.00 0 45,500 10.50 10.30 9.10 0 45,500 10.50 10.30 8.80 0 46,500 10.50 10.30 9.10 0 47,000 10.50 10.30 9.15 0 47,000 10.50 10.30 9.10 0 48,000 10.50 10.30 9.15 0 47,500 10.50 10.30 9.15 0 47,500 - 10.50 9.05 0 47,500 - 10.50 9.05 0 48,000 - 10.50 9.10 0 48,000 - 10.50 9.10 048 -30 FG3AAA048 1500 46,000 10.50 10.30 9.10 o 03 0 48,000 10.50 10.30 9.15 0 48,000 - 11.00 10.20 28RDS /RNS148 1500 45,500 10.50 10.10 8.85 28RDS /RNS248 1500 46,000 10.50 10.10 8.85 28RDS /RNS057 1500 46,500 10.50 10.10 8.90 28RDS /RNS061 1500 47,500 10.70 10.50 9.25 28RH048 1500 45,500 10.50 10.10 8.85 28R11060 1500 46,500 10.50 10.10 8,90 28RM048 1500 45,500 10.50 10.10 8.85 28SLSO49 1500 46,500 10.50 10.10 8.85 28SLS061 1500 49,000 10.80 10.50 9.20 40LT048 1500 45,500 10.40 10.10 8.85 40LT060 1500 47,000 10.50 10.30 9.05 40YR /YR(A,U,F,G,M)048 1500 46,000 10.50 10.10 8.80 40YR /YR(U,F,G,M)060 1500 47,500 10.50 10.10 8.90 40YA/YAF048 1500 47,500 - 10.70 9.35 40YA/YAF060 1500 48,000 - 11.00 9.60 40YZM005 1500 47,500 - 11.00 9.40 40YZM006 1500 48,000 - 11.30 9.65 *CC5A /CD5AW060 2125 57,500 10.50 10.30 9.25 m m m m m m m m m ao w m m m m m m m m CC5A/CD5AA060 1800 55,000 10.50 10.30 9.10 CA5A /CB5AA060 1800 55,500 10.50 10.20 9,15 CA5A /CB5AW060 2125 57,000 10.50 10.30 9.20 CD3AA060 1800 55,000 10.50 10.30 9.10 CE3AA060 2000 58,000 10.80 10.50 9.30 FB5AN(A,F)060 2000 57,500 - 10.40 9.25 FB4AN(A,M,F)060 2000 57,500 - 10.40 9.25 FB4AN(M,F)070 2000 58,500 - 10.80 9.65 080.30 FG3AAA060 2125 57,000 10.70 10.30 9.15 CO N FK4ANFOO6 1870 58,000 - 11.00 9.75 28RDS /RNS057 2000 54,500 10.30 10.00 8.80 28RDS /RNS061 2125 57,500 10.50 10.30 9.10 28RH060 2000 54,500 10.30 10.00 8.80 28SLS061 2000 58,000 10.50 10.00 8.80 40LT060 2125 55,500 10.50 10.00 8.80 40YR /YR(U,M,F,G)060 2000 55,500 10.00 9.70 9.20 40YA/YAF060 2000 58,000 - 11.00 9.10 40YZM006 1870 58,000 - 11.00 9.40 SEAS. EFF. W/O TDR. 90t SEER 10.10 10.10 10.10 10.00 10.10 10.10 10.00 10.00 10.00 10.00 10.10 10.10 10.00 10.10 10.00 10.00 10.20 10.20 10.00 11.00 10.10 10.00 10.00 9.90 10.10 10.10 10.10 10.20 10.00 10.00 9.80 9.90 10.00 10.00 9.50 10.00 10.30 10.50 11.00 10.20 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.50 10.50 10.00 11.00 10.00 10.00 10.10 10.10 10.20 10.00 10.10 10.00 10.00 10.00 10.00 10.20 10.00 10.00 EER 3 -ph 9.50 9.20 9.20 9.15 9.25 9.25 9.40 9.40 9.40 9.35 9.20 9.25 9.15 9.25 9.15 8.95 9.15 9.15 9.15 9.80 9.50 9.15 9.15 9.05 9.25 9.25 9.25 9.35 9.15 9.15 8.95 9.05 9.15 9.15 8.70 9,15 9.20 9,40 9.80 SOUND RATING (BELS) 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8,0 8.0 8,0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8,0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 SOUND RATING W /ACCESSORY SOUND BLANKET (BELS) 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8,0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8,0 8.0 8,0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 Performance continued tSee TDR Table *Tested Combination NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat Is not included. 2. Tested outdoor /indoor combinations have been tested in accordance w /DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual cfm values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 4. The dashes ( -) appearing In the SEAS. EFF. W /TDR.90+ SEER column indicate no Improvement in efficiency due to factory installed hard shut -off TXV (40YA, 40YZ and FK4A Fan Coils), or time -delay function built into TDR board as manufactured (FB4A, FB5A). 1 1 METHOD PART /MODEL NUMBER Indoor Fan Time - Delay Relay 38TH900001 /KAATD0101 TDR Furnaces 58SSC /5BDHC, 58SX, 58DX, 58SXB, 58GFA /DFA, 58PAP /RAP, 58RAV, 58EJA Fan Coils FB4A, FB5A NOTE: In most cases, only one of the above should be used to achieve TDR function. More than one of the meth- ods listed above in a system may cause degradation in performance. CVM UNRIUM AIR 85 95 105 115 CFM 550 W3 m n m�n Capacity MB Of Total System Kw** 1.79 1.73 1.67 1.64 Capacity MBtuht Total System Kw** CD5AA018 1.89 1.82 1.76 1.73 Capacity MBtuht Total System Kw** 1.99 1.91 1.84 1.82 Capacity MB uht Total System Kw** 2.08 2.00 1.92 1.91 Total 16.6 15.0 13.4 13.2 Sens$ 8.50 10.9 13.0 13.2 Total I.door 17.8 16.1 14.5 14.0 Senst Section 8.95 11.4 13.6 14.0 Total Section 19.0 17.2 15.5 14.8 Senst With 9.39 11.8 14.2 14.8 Total 20.1 18.3 16.5 15.6 Senst 38TKB01 9.80 12.3 14.7 15.6 600 72 67 62 57 20.4 18.5 16.7 16.0 ,-r oci It) cc 1.82 1.76 1.70 1.67 19.2 17.4 15.7 15.2 9.64 12.3 14.7 15.2 1.92 1.85 1.79 1.77 18.0 16.3 14.7 14.4 9.20 11.8 14.2 14.4 2.02 1.94 1.87 1.86 16.8 15.1 13.6 13.5 8.75 11.3 13.5 13.5 2.11 2.03 1.96 1.95 875 72 67 62 57 20.7 18.8 17.0 16.5 10.4 13.4 16.1 16.5 1.87 1.80 1.74 1.72 19.5 17.7 16.0 15.7 10.0 12.9 15.5 15.7 1.96 1.89 1.83 1.82 18.3 16.5 14.9 14.8 9.58 12.5 14.8 14.8 2.06 1.99 1.92 1.91 17.0 15.3 14.0 14.0 9.12 12.0 14.0 14.0 2.16 2.08 2.01 2.01 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity Power Cupacity Power CC5A/CD5AA 018 1.00 1.00 28RDS /RNS 018 0.96 0.98 019 1.00 1.00 024 1.02 1.01 024 1.00 1.00 CA5A /CB5AA 018 0.99 0.99 024 1.01 0.99 40DQS 018 0.94 1.00 024 0.98 0.99 CD3AA 018 0.99 1.00 024 1.02 1.01 4ORC 018 1.00 0.97 CE3AA 024 1.03 1.02 024 0.99 1.01 CF5AA 024 1,03 1.02 28RH 018 0.96 0,98 024 1.00 1.00 FB(5,4)AN(A,F) 018 0.98 1.00 024 1.02 1.05 28SLS 024 0.98 0.99 FD3ANA 018 0.99 1.04 28RM 024 0.99 1.00 024 1.02 1.02 4OLT 024 1.00 1.00 FF1ANA 018 0.99 0.97 40YR /YR(U,F,G) 018 0.98 0.98 024 1.01 1.01 024 1.02 1.04 FG3AAA 024 1.02 1.02 40YA/YAF 018 1.01 0.98 FK4ANF 002 1.05 0.94 024 1.04 1.01 CD5AA 018 1,00 1.00 40YZ 002 1.05 0.94 38TKB02L Detailed cooling capacities* CONDENSER ENTERING AIR TEMPERATURES F See notes on pg. 19. 12 ei• EVAPORATOR AIR E CFM W B 700 800 900 Indoor Section CE3AA FF1ANA 72 67 62 57 72 67 62 57 72 67 62 57 CC5A /CD5AA CC5A /CD5AW CC5A /CB5AA CB5AA CA5A /CB5AW CD3AA CF5AA FB(5,4)AN(A,F) FB5AN(A,F) FB4A(A,F) FD3ANA FG3ANA FK4ANF See notes on pg. 19. Capacity To MBtuht Syst Total Sens$ Kw 25.7 23.3 21.1 20.1 26.2 23.8 21.6 20.9 26.6 24.2 22.0 21.6 Size 024 030 030 024 030 030 024 030 024 030 024 024 030 030 024 030 024 030 024 002 85 12.6 15.9 19.0 20.1 13.2 16.8 20.2 20.9 13.7 17.7 21.3 21.6 Mu 2.4 2.3 2.2 2.1 2.4 2.3 2.2 2.2 2.5 2.4 2.3 2.3 Capacity 1.00 1.00 1.00 0.98 0.98 0.98 0.99 1.00 1.00 1.01 0.99 0.99 0.99 1.03 0.96 1.00 0.99 1.00 0.96 1.02 TDR.90 TABLE • Detailed cooling c tiplier { EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES F 85 95 105 115 CFM 700 U.103 I hlt.-C•It... Capacity MB uht Total System Kw** Outdoor 2.40 2.30 2.20 2.16 Capacity MB uht Total System Kw** CD5AA024 2.52 2.41 2.31 2.27 Capacity MB uht Total System Kw ** 2.64 2.52 2.41 2.39 Capacity Metuht Total System Kw" 2.75 2.63 2.51 2.50 Total 25.7 23.3 21.1 20.1 Sens$ 38TKB024 12.6 15.9 19.0 20.1 Total Section 24.3 22.0 19.8 19.1 Sens$ With 12.1 15.3 18.3 19.1 Total 21.2 19.1 17.2 17.0 Sens$ 11.0 14.1 16.9 17.0 Total Indoor 22.7 20.5 18.5 18.0 Sens$ Section 11.5 14.7 17.6 18.0 800 72 67 62 57 26.2 23.8 21.6 20.9 13.2 16.8 20.2 20.9 2.47 2.36 2.27 2.24 24.7 22.4 20.2 19.8 12.6 16.2 19.5 19.8 2.59 2.47 2.37 2.35 23.1 20.9 18,9 18.8 12.1 15.6 18.7 18.8 2.70 2.58 2.48 2.47 21.5 19.4 17.7 17.7 11.5 15.0 17.7 17.7 2.82 2.69 2.58 2.58 900 72 67 62 57 26.6 24.2 22.0 21.6 13.7 17.7 21.3 21.6 2.53 2.42 2.33 2.31 25.1 22.7 20.6 20.5 13.2 17.2 20.5 20.5 2.65 2.54 2.44 2.43 23.4 21.2 19.4 19.4 12.6 16.5 19.4 19.4 2.76 2.64 2.54 2.54 21.8 19.6 18.2 18.2 12.0 15.9 18.2 18.2 2.87 2.75 2.66 2.66 Mu tipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity Power Capacity Power CC5A /CD5AA 024 1.00 1.00 CD5AA 024 1.00 1.00 030 1.00 1.01 28RDS /RNS 024 0,96 0.98 025 0,97 0.99 CC5A/CD5AW 030 1.00 1.01 030 1.00 1,00 CC5A /CB5AA 024 0.98 0.99 030 1.00 1.00 CB5AA 030 0.98 0.99 CA5A /CB5AW 030 0.98 0.99 28RH 024 0.96 0.98 030 1.00 1.00 CD3AA 024 0.99 1.00 030 1.00 1.01 4ORC 024 0.94 0.98 030 0.96 1.01 CE3AA 024 1.00 1.00 030 1.01 1.01 28RM 024 0.95 0.98 CF5AA 024 0.99 1.00 28SLS 024 0.94 0.97 030 0.96 0.98 FB(5,4)AN(A,F) 024 0.99 1.00 FB5AN(A,F) 030 0.99 1.01 40DQS 024 0.94 0.97 030 0.97 1.02 FB4A(A,F) 030 1.03 1.02 FD3ANA 024 0.96 0.98 4OLT 024 0.95 0.98 030 1.00 1.04 40YR /YR(F,U,G) 024 0.96 1.01 030 1.00 1.02 FF1ANA 024 0.99 1.01 030 1.00 1,04 40YA/YAF 024 1.01 0.99 030 1.01 0.99 FG3ANA 024 0.96 0.99 FK4ANF 002 1.02 0.93 40YZ 002 1.02 0.94 Indoor Section ER B, 58GFA /DFA, should be used one of the meth - use degradation In PERATURES F pacify tuht 105 8.95 11.4 13.6 14.0 9.20 11.8 14.2 14.4 9.58 12.5 14.8 14.8 Indoor Sections Total System Kw** 1.99 1.91 1.84 1.82 2.02 1.94 1.87 1.86 2.06 1.99 1.92 1.91 Total 16.6 15.0 13.4 13.2 16.8 15.1 13.6 13.5 17.0 15.3 14.0 14.0 {:!: ...Vi Capacity MB uht Cooling 115 Sens$ 8.50 10.9 13.0 13.2 8.75 11.3 13.5 13.5 9.12 12.0 14.0 14.0 Total System Kw** 2.08 2.00 1.92 1.91 2.11 2.03 1.96 1.95 2.16 2.08 2.01 2.01 Detailed cooling capacities See notes on pg. 19. continued 13 Size Capacity Power 018 0.96 0.98 019 1.00 1.00 024 1.00 1,00 018 0.94 1.00 024 0.98 0.99 018 1.00 0.97 024 0.99 1.01 018 0.96 0.98 024 1.00 1.00 024 0.98 0.99 024 0.99 1.00 024 1.00 1.00 018 0.98 0.98 024 1.01 1.01 018 1.01 0.98 024 1.04 1.01 002 1.05 0.94 Indoor Section ER B, 58GFA /DFA, should be used one of the meth - use degradation In PERATURES F pacify tuht 105 8.95 11.4 13.6 14.0 9.20 11.8 14.2 14.4 9.58 12.5 14.8 14.8 Indoor Sections Total System Kw** 1.99 1.91 1.84 1.82 2.02 1.94 1.87 1.86 2.06 1.99 1.92 1.91 Total 16.6 15.0 13.4 13.2 16.8 15.1 13.6 13.5 17.0 15.3 14.0 14.0 {:!: ...Vi Capacity MB uht Cooling 115 Sens$ 8.50 10.9 13.0 13.2 8.75 11.3 13.5 13.5 9.12 12.0 14.0 14.0 Total System Kw** 2.08 2.00 1.92 1.91 2.11 2.03 1.96 1.95 2.16 2.08 2.01 2.01 Detailed cooling capacities See notes on pg. 19. continued 13 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES F 85 95 105 115 CFM 900 CO nCDCDIn Capacity MBtuht Total System Kw** Outdoor 3.00 2.89 2.78 2.73 Capacity MBtuht Total System Kw** CD5AA030 3.19 3.06 2.94 2.90 Capacity MBtuht Total System Kw ** 3.37 3,23 3.09 3,06 Capacity MBtuht Total System Kw** 3.54 3.39 3.24 3.22 Total 32.9 29.8 26.9 25.6 Sens$ 38TKB030 16.1 20.3 24.2 25.6 Total Section 31.0 28.0 25.2 24.3 Sens$ With 15.4 19.5 23.3 24.3 Total 27.0 24.4 21.9 21.6 Sens$ 14,0 18.0 21.5 21.6 Total Indoor 29.0 26.2 23.5 23.0 Sens$ Section 14.7 18.7 22.5 23.0 1000 72 67 62 57 33.5 30.3 27.4 26.4 16.7 21.2 25.4 26.4 3.06 2.95 2.84 2.80 31.5 28.5 25.7 25.1 16.0 20.4 24.5 25.1 3.25 3.12 3.00 2.97 29.4 26.6 24.0 23.7 15.2 19.7 23.5 23.7 3.43 3,29 3.16 3.14 27,4 24.7 22.3 22.3 14.5 18.9 22.3 22.3 3.61 3.45 3.31 3.31 1100 72 67 62 57 33.9 30.8 27.8 27.1 17.2 22.1 26.6 27.1 3.12 3.00 2.89 2.87 31.8 28,8 26.1 25.7 16.5 21.3 25.5 25.7 3.30 3.18 3.06 3.04 29.7 26.9 24.4 24.3 15.7 20,6 24.3 24.3 3.49 3.35 3.22 3.22 27.7 25.0 22.9 22.9 15.0 19.8 22.9 22,9 3.67 3.51 3.39 3.39 Mu tipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity Power Capacity Power CC5A /CD5AA 030 1.00 1.00 FK4ANF 002 1.01 0.95 036 1.04 1.01 CD5AA 030 1.00 1.00 CC5A /CD5AW 030 0.99 1.00 28RDS /RNS 030 0,99 0.99 CD5AW 036 1.04 1.01 030 0.99 0.99 CB5AA 030 0.99 1.00 036 1.01 1.00 CA5A /CB5AW 030 0.99 1.00 28RDS 036 1.00 1.00 CA5A /CB5AA 036 1.03 1.01 40DQS 030 0.96 1.01 CB5AW 036 1.03 1.01 4ORC 030 0.94 1.00 CD3AA 030 0.99 1.00 28RH 030 0,99 0.99 036 1.04 1.01 036 1.00 1.00 CE3AA 030 0.99 1.00 28RM 036 0,96 0.99 036 1.02 1.01 28SLS 030 0.95 0,98 CF5AA 036 1.03 1.01 036 0.98 0.99 FB5AN(A,F) 030 0.99 1.01 4OLT 036 0.99 1,00 FB4AN(A,F) 030 1.01 1.02 40YR/YR(F,U,G) 030 0.98 0,99 FB(5,4)AN(A,F) 038 1.01 1.05 036 0.99 1.01 FD3ANA 030 0.99 1,03 40YA/YAF 030 0.99 1.00 FF1ANA 030 1,00 1.02 036 1.04 1.03 FG3AAA 036 1.00 1.00 40YZ 002 1.01 0.95 38TKB03 • Detailed cooling capacities* continued See notes on pg. 19. 14 • • Detailed cooling c EVAPORATOR AIR CFM 1050 1200 1350 Indoor Section E W B 72 67 62 57 72 67 62 57 72 67 62 57 CC5A/CD5AA CD5AW CC5A/CD5AW CA5A /CB5AA CB5AW CA5A /CB5AW CD3AA CE3AA CF5AA FB(5,4)AN(A,F) FB5AN(A,F) FB4AN(A,M,F) FG3AAA See notes on pg, 19. Total Sens$ 38.6 35.0 31.6 30.5 39.4 35.7 32.3 31.8 39.9 36,2 33.0 32.8 Size Capacity 036 042 043 036 042 043 036 042 036 042 036 042 036 042 036 036 042 042 036 Capacity MBtuht 85 19.3 24.4 29.2 30.5 20.2 26.0 31.2 31.8 21.0 3. 27.5 3.5 32.8 3. 32.8 3. Mu tiplier 1.00 1.00 0,99 0.99 ,, EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES F 85 95 105 115 CFM 1050 US al I �CDCD Capacity MBtuht Total System Kw** Outdoor 3.48 3.34 3.21 3.17 Capacity MBtuht Total System Kw** CD5AA036 3.69 3.54 3.39 3.37 Capacity MBtuht Total System Kw** 3.90 3.73 3.58 3.56 Capacity MBtuht Total System Kw ** 4.10 3.92 3.75 3.75 Total 38.6 35.0 31.6 30.5 Sens$ 38TKB036 19.3 24.4 29.2 30.5 Total Section 36.3 32.8 29.6 28.9 Sens$ With 18.4 23.5 28.2 28.9 Total Indoor 33.9 30.6 27.6 27.3 Sens$ Section 17.5 22.6 27.1 27.3 Total 31.5 28.3 25.6 25.6 Sens$ 16.7 21.7 25.6 25.6 1200 72 67 62 57 39.4 35.7 32.3 31.8 20.2 26.0 31.2 31.8 3.57 3.43 3.30 3.28 36.9 33.4 30.3 30.1 19.3 25.0 30.0 30.1 3.78 3.63 3.49 3.48 34.4 31.1 28.4 28.4 18.4 24.1 28.4 28.4 3.99 3.82 3.68 3.68 32.0 28.8 28.6 26.6 17.6 23.2 26.6 26.6 4.19 4.01 3.88 3.88 1350 72 67 62 57 39.9 36.2 33.0 32.8 21.0 27.5 32.8 32.8 3,66 3.52 3.39 3.38 37.4 33.9 31.1 31.1 20.2 26.5 31.1 31.1 3.87 3.71 3.59 3.59 34.9 31.5 29.3 29.3 19.3 25.6 29.3 29.3 4.07 3.91 3.79 3.79 32.3 29.1 27.4 27.4 18.4 24.6 27.4 27.4 4.28 • 4.09 3.99 3.99 Mu tipliers for Determining the Performance With Other indoor Sections Indoor Section Size Coo ing Indoor Section Size Cooing Capacity Power Capacity Power CC5A/CD5AA 036 1,00 1.00 FK4ANF 003 0.99 0.93 042 1.00 1.00 CDSAA 036 1.00 1.00 043 0.99 1.00 28RDS 036 0.96 0.98 CD5AW 036 1.00 1.00 28RDS /RNS 036 0.96 0.98 CC5A/CD5AW 042 0.99 1.00 042 0.95 0.98 043 0.99 1.00 242 0.98 0.99 CA5A/CB5AA 036 1,00 1.00 043 0.99 1.00 042 1.00 1.00 043 0.99 1.00 CB5AW 036 1.00 1.00 28RH 036 0.96 0.98 042 0.95 0.98 CA5A /CB5AW 042 0.99 1.00 CD3AA 036 1.00 1.00 28RM 036 0.92 0.97 042 1.00 1.00 28SLS 036 0.94 0,98 042 0.96 0.99 CE3AA 036 0.99 0.99 042 0.99 1.00 4OLT 036 0.95 0.98 CF5AA 036 0,99 1.00 40YR /YR(U,F,G) 036 0.93 0.99 FB(5,4)AN(A,F) 036 0.97 1.00 40YR /YR (A,U,F,G,M) 042 0.97 1.00 FB5AN(A,F) 042 1.00 1.02 FB4AN(A,M,F) 042 ' 1.00 1.02 40YA/YAF 036 0.98 1.01 FG3AAA 036 0.96 ' 0.99 40YA/YA 042 1.01 1.01 40YZ 003 0.99 0.93 105 115 Capacity MBtuht t Total System Kw** 3.37 3.23 3.09 3.06 Capacity MBtuh t Total System Kw** 3.54 3.39 3.24 3.22 'oral 030'Iudoor 29.0 ?6.2 23.5 23.0 Sens$ Section 14.7 18.7 22.5 23.0 Total 27.0 24.4 21.9 21.6 Sens$ 14.0 18.0 21.5 21.6 29.4 26.6 24.0 23.7 15.2 19.7 23.5 23.7 3.43 3.29 3.16 3.14 27.4 24.7 22.3 22.3 14.5 18.9 22.3 22.3 3.61 3.45 3.31 3.31 29.7 26.9 24.4 24.3 15.7 20.6 24.3 24.3 3.49 3.35 3.22 3.22 27.7 25.0 22.9 22.9 15.0 19,8 22,9 22.9 3.67 3.51 ' 3.39 3.39 Other h door Sections Size Cooling Capacity Power 002 1.01 0.95 030 1.00 1.00 IS 030 0.99 0.99 030 0.99 0.99 036 1.01 1.00 036 1.00 1.00 030 0.96 1.01 030 0.94 1.00 030 0.99 0.99 036 1.00 1,00 036 0.96 0,99 030 0.95 0.98 036 0.98 0.99 036 0.99 1.00 U,G) 030 0.98 0.99 036 0.99 1,01 F 030 0.99 1,00 036 1.04 1.03 002 1.01 0.95 wed I TEMPERATURES F 41 sie 0 Detailed cooling capacities* continued See notes on pg. 19. 15 CVAYVMM V11 AIR 85 95 105 115 Cool Cooling W nmCD� Capacity Total Capacity Total Capacity Total Capacity MBtuht Total CFM MBtuht System Kw** MBtuht System Kw** MBtuht System Kw** 0.98 System Kw** Total Sens$ Total Sens$ Total Sens* Total Sens* 0.99 0.98 38TKB038 Outdoor Section With CD5AA036 Indoor Section 0.99 1.00 142 0.99 0.98 40.8 19.9 3.98 38.4 19.0 4.24 36.0 18.1 4.48 33.6 17.2 4.72 1150 36.9 33.3 24.9 29.6 3.86 3.73 34.7 31.3 23.9 28.6 4.09 3.95 32.5 29.3 23.0 27.6 4.32 4.17 30.3 27.3 22.1 28.5 4.55 4.38 0.99 31.5 31.5 3.67 30.0 30.0 3.90 28.4 28.4 4.13 26.9 26.9 4.36 28RM 72 41.9 21.0 4.10 39.3 20.1 4.35 36.8 19.2 4.61 34.3 18.3 4.85 1350 67 62 37.9 34.3 26.7 32.1 3.97 3.85 35.6 32.2 25.8 30.9 4.21 4.07 33.3 30.1 24.8 29.7 4.44 4.29 31.0 28.1 23.9 28.1 4.67 4.52 0.99 57 33.2 33.2 3.81 31.5 31.5 4.05 29.8 29.8 4.28 28.1 28.1 4.52 042 72 42.6 22.0 4.21 40.0 21.1 4.47 37.4 20.1 4.71 34.8 19.2 4.96 1550 67 62 38.7 35.1 28.5 34.1 4.08 3.96 36.3 32.9 27.5 32.7 4.32 4.19 33.8 31.0 26.5 31.0 4.55 4.42 31.4 29.2 25.6 29.2 4.78 4.66 57 34.6 34.6 3.94 32.8 32.8 4.18 31.0 31.0 4.42 29.2 29.2 4.66 Multipliers for Determinino the Performance With Other Indoor Sections Indoor Section Size Coo Mg Section Size Cool Cooling Capacity Power Capacity Power CC5A /CD5AA 036 0.99 0.98 28RDS 136 0.99 0.97 042 1.00 1.00 042 0.98 0.98 043 1.00 1.00 049 1.00 1.00 CD5AW 036 0.99 0.98 28RDS /RNS 036 0.99 0.97 CC5A /CD5AW 042 0.99 1.00 142 0.99 0.98 043 1,00 1.00 242 1.00 0.99 CA5A /CB5AA 036 1.01 0.99 043 1.00 1.00 042 1.02 1.01 143 1.00 1.00 CB5AW 036 1.01 0.99 28RH 036 0.99 0.97 CA5A /CB5AW 042 1.00 1.01 042 0.99 0.98 CD3AA 036 0.99 0.98 28RM 036 0,97 0.97 042 1.00 1.00 28SLS 036 0.98 0,98 CE3AA 036 0.98 0,97 042 1.00 0.98 042 1.01 1.00 4OLT 036 0.99 0.98 CF5AA 036 0.99 0.99 40YR /YR(U,F,G) 036 0,97 0.99 FB(5,4)AN(A,F) 036 0.98 1.02 40YR /YR (A,U,F,G,M) 042 1.00 1.00 FB5AN(A,F) 042 1.01 1.01 FB4AN(A,M,F) 042 1.01 1.01 40YA/YAF 036 1.00 1.01 FG3AAA 036 1.00 0.99 042 1.00 1.02 FK4ANF 003 1.00 0.92 40YZM 003 1.00 0.92 Total 38TKI304 72 67 62 57 72 67 62 57 D5AW AA AC AA AA Capacity To W MBtuht Sys B Sens$ Kw 72 46.2 67 41.9 62 37.8 57 36.2 A,M,F) on pg. 19. 47.0 42.7 38.6 37.5 47.9 43.4 39.4 39.0 Size 042 042 043 042 043 048 048 048 042 042 048 048 048 042 048 042 048 048 042 048 042 85 22.8 28.7 34.4 36.2 23.7 30.3 36.3 37.5 24.8 32,2 38.6 39.0 Mul 4 3 3 3 4. 3. 3. 3. 4. 4. 3. 3. Capacity 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.01 1.01 1.01 0.96 1.00 1.00 1.00 1.01 1.03 1.00 1.03 1.00 • Detailed cooling capacities* continued See notes on pg. 19. 16 CONDENSER ENTERING AIR TEMPERATURES F S Detailed cooling c EVAPORATOR AIR CFM 1225 1375 1575 Indoor Section CD5AA CC5A/CD5AA CC5A /C CD5AA CC5A/CD5AC CA5A /CB5AA CA5A /CB5AW CB5 CB5 CD3 CE3 CF5AA FB5AN(A,F) FB4AN( See notes iplier EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES F 85 95 105 115 CFM 1225 N I , W 3 1� C0 CD 1.0 Capacity MBtuht Total System Kw** Outdoor 4 01 3.89 3.77 3.72 Capacity MBtuht Total System Kw** CD5AA042 4.26 4.12 3.99 3.95 Capacity MBtuht Total System Kw** 4.51 4.36 4.21 4.18 Capacity MBtuht Total System Kw** 4.76 4.59 4.42 4.41 Total 46.2 41.9 37.8 36.2 Sens$ 38TKB042 22.8 28.7 34.4 36.2 Total Section 43.5 39.3 35.5 34.4 Sens$ With 21.8 27.7 33.2 34.4 Total Indoor 40.7 36.8 33.2 32.5 Sens$ Section 20.8 26.6 32.0 32.5 Total 37.9 34.2 30.8 30.5 Sens$ 19.8 25.6 30.5 30.5 1375 72 67 62 57 47.0 42.7 38.6 37.5 23.7 30.3 36.3 37.5 4.09 3.97 3.85 3.82 44.2 40.0 36.2 35.6 22.7 29.2 35.0 35.6 4.35 4.21 4.08 4.05 41.3 37.3 33.9 33.7 21.6 28.1 33.6 33.7 4.60 4.45 4.30 4.29 38.5 34.7 31.6 31.6 20.6 27.1 31.6 31.6 4.85 4.67 4.53 4.53 1575 72 67 62 57 47.9 43.4 39.4 39.0 24.8 32.2 38.6 39.0 4.20 4.07 3.96 3.94 44.9 40.7 37.0 36.9 23.8 31.1 36.9 36.9 4.46 4.32 4.19 4.19 41.9 37.9 34.9 34,9 22.7 30.0 34.9 34.9 4.71 4.55 4.43 4.43 39.0 35,2 32.8 32.8 21.7 28.9 32.8 32.8 4.96 4.78 4.67 4.67 Mu tipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Coo ing Indoor Section Size Cooling Capacity Power Capacity Power CD5AA 042 1,00 1.00 FB4AN(A,M,F) 048 1.03 1.02 CC5A /CD5AA 042 1.00 1.00 FG3AAA 048 1.00 1.00 043 1,00 1.00 FK4ANF 004 1.03 0.96 CC5A /CD5AW 042 1.00 1.01 28RDS /RNS 042 0.95 0.98 242 0.98 0.99 043 1,00 1.00 043 1.00 1.00 048 1.00 1.00 043 0.99 1.00 CD5AA 048 1.00 1.00 048 0.98 0.99 CC5A/CD5AC 048 1.00 1.00 048 0.99 0,99 CA5A /CB5AA 042 1.01 1.01 CA5A /CB5AW 042 1,01 1.01 28RDS 049 1.00 1.00 048 1.01 1.01 28RH 042 0.95 0.98 048 0.98 0,99 CB5AA 048 1.01 1.01 CB5AC 048 0.96 1,00 28RM 048 0.98 0.99 CD3AA 042 1.00 1.00 2BSLS 042 0.95 0.98 048 1,00 1.00 048 1.00 1.00 CE3AA 042 1.00 1,00 4OLT 048 0.98 0,99 048 1.01 1.01 40YR /YR(U,M,F,G) 042 0.98 1.00 048 0.99 1.00 CF5AA 048 1.03 1.01 FB5AN(A,F) 042 1.00 1.02 40YA /YAF 042 1.03 1.02 048 1.04 1.02 048 1.03 1,02 FB4AN(A,M,F) 042 1.00 1.02 40YZM 004 1.03 0.96 Sens$ 136 Indoor Section 105 Capacity MBtuht 0 5 3 4 8 .3 1 8 .4 .8 .0 .0 ERATURES F 18.1 23.0 27.6 28.4 19.2 24.8 29.7 29.8 4.61 4.44 4.29 4.28 20.1 26.5 31.0 31.0 Total System Kw ** 4.48 4.32 4.17 4.13 4.71 4.55 4.42 4.42 Capacity MBtuht Total 33.6 30.3 27.3 26.9 34.3 31.0 28.1 28.1 34.8 31.4 29.2 29.2 115 Sens$ 17.2 22.1 26.5 26.9 18.3 23.9 28.1 28.1 19.2 25.6 29.2 29.2 S ued EMP her Indoor Sections Total System Kw** 4.72 4.55 4.38 4.36 4.85 4.67 4.52 4.52 4.96 4.78 4.66 4.66 See notes on pg. 19. 0 Detailed cooling capacities* continued 17 Size Cooling Capacity Power 136 0.99 0.97 042 0.98 0,98 049 1.00 1.00 036 0.99 0.97 142 0.99 0.98 242 1.00 0.99 043 1.00 1.00 143 1.00 1.00 036 0.99 0.97 042 0.99 0,98 036 0.97 0.97 036 0.98 0.98 042 1.00 0.98 036 0.99 0.98 G) 036 0.97 0.99 042 1.00 1.00 036 1,00 1.01 042 1.00 1,02 003 1.00 0.92 Sens$ 136 Indoor Section 105 Capacity MBtuht 0 5 3 4 8 .3 1 8 .4 .8 .0 .0 ERATURES F 18.1 23.0 27.6 28.4 19.2 24.8 29.7 29.8 4.61 4.44 4.29 4.28 20.1 26.5 31.0 31.0 Total System Kw ** 4.48 4.32 4.17 4.13 4.71 4.55 4.42 4.42 Capacity MBtuht Total 33.6 30.3 27.3 26.9 34.3 31.0 28.1 28.1 34.8 31.4 29.2 29.2 115 Sens$ 17.2 22.1 26.5 26.9 18.3 23.9 28.1 28.1 19.2 25.6 29.2 29.2 S ued EMP her Indoor Sections Total System Kw** 4.72 4.55 4.38 4.36 4.85 4.67 4.52 4.52 4.96 4.78 4.66 4.66 See notes on pg. 19. 0 Detailed cooling capacities* continued 17 cvhrvnMI vn AIR 85 95 105 115 CFM 1500 N Fs- I+ CD CD CD! Capacity MBtuht Total System Kw" 4.72 4,59 4.47 4.43 Capacity MBtuht Total System Kw** CD5AA048 5.16 5.03 4.91 4.87 Capacity MBtuht Total System Kw** 5.65 5.51 5.37 5.34 Capacity MBtuht Total System Kw** 6.17 6.01 5.86 5.84 Total 45,9 41.7 37.9 37.4 Sens$ 23.6 30.6 36.8 37.4 Total ladoor 48.5 44.2 40.1 39.1 Sens$ Section 24.6 31.5 38.0 39.1 Total Section 51.1 46.5 42.3 40.8 Sens$ With 25.5 32.5 39.1 40.8 Total 53.4 48.7 44.3 42.4 Sens$ 38TKB048Outdoor 26.4 33.4 40.2 42.4 1600 72 67 62 57 53.9 49.2 44.7 43.2 27.0 34.4 41.4 43.2 4.77 4.64 4.53 4.49 51.5 46.9 42.6 41.5 26.1 33.4 40.3 41.5 5.21 5.08 4.96 4.93 48.9 44.5 40.5 39.8 25.1 32.5 39.1 39.8 5.70 5.56 5.43 5.40 46.2 42.1 38.3 38.0 24.2 31.5 37.8 38.0 6.23 6.07 5.92 5.91 1700 72 67 62 57 54.4 49.6 45.1 43.9 27.5 35.3 42.6 43.9 4.82 4.69 4.58 4.55 51.9 47.3 43.0 42.2 26.6 34.3 41.4 42.2 5.27 5.13 5.01 4.99 49.3 44.8 40.8 40.4 25.7 33.4 40.1 40.4 5,76 5.61 5.48 5.47 46.5 42.3 38.6 38.6 24.7 32.4 38.6 38.6 6.28 6.12 5.98 5.97 Mu tipilers for Determining the Performance With Other Indoor Sections Indoor Section Size Coo ing Indoor Section Size Coo Ing Capacity Power Capacity Power CD5AA 048 1.00 1.00 FG3AAA 048 0.99 1.00 _ CC5AICD5AA 048 1.00 1.00 060 1.03 1.01 060 1.01 1.00 FK4ANF 005 1.03 1.00 CC5A /CD5AC 048 1.00 1.00 28RDS /RNS 148 0.98 0.99 CC5A/CD5AW 048 1.00 1.00 248 0.99 1.00 060 1.03 1,01 057 1.00 1.00 CB5AA 048 1.02 1.04 061 1.02 1.01 CB5AC 048 0.98 0.99 28RH 048 0.98 0,99 CA5AICB5AW 048 1.02 1.04 060 1.00 1.00 060 0.98 0.98 28RM 048 0.98 0.99 CA5A /CB5AA 060 0,98 0.98 28SLS 049 1.00 1.00 CD3AA 048 1.00 1.00 061 1.05 1.01 060 1.01 1.00 4OLT 048 0.98 0,99 CE3AA 048 1.01 1.00 060 1.01 1.00 060 1.03 1.01 40YR /YR(U,M,F,G) 048 0.99 1.00 CF5AA 048 1.02 1.00 060 1.02 1.05 FB5AN(A,F) 048 1.02 1.01 40YA/YAM 048 1.02 1,02 060 1,03 1.04 060 1.03 1.03 FB4AN(A,M,F) 048 1.02 1.01 40YZM 005 1.02 1.00 060 1.03 1.04 006 1.03 1.00 Total 38TKB06 72 65.9 67 60.2 62 55.0 57 54.1 EVAPORATOR AIR E CFM W B 1750 2000 2125 2250 Indoor Section CD5AA CC5A /CD5AW CC5A/CD5AA CA5A /CB5AA CA5A /CB5AW CD3AA CE3AA FB5AN(A,F) FB4AN(A,M,F) FB4AN(M,F) 72 63.8 67 58.2 62 53.0 57 50.5 72 65.0 67 59.4 62 54.1 57 52.4 72 65.5 67 59.8 62 54.6 57 53.3 Capacity MB uht Size 060 060 060 060 060 080 060 060 060 070 85 31.3 39.5 47.5 50.5 32.7 41.8 50.5 52.4 33.4 43.0 51.9 53.3 34.0 44,1 53.2 54.1 Mu 'Detailed cooling capacities are based on I (7.62m) of tubing is used and /or Indoor un tTotal and sensible capacities are net cap #Sensible capacities shown are based on Btuh (245 kw) per 1000 cfm (480 L /S) of Indoor coil air per degree above 80 F (27 When the required data falls between the "'Unit kw Is total of Indoor and outdoor un T Sy K 5. 5, 5. 5. 5. 5. 5. 5. 5. 5. 5. 5. 5. 5. 5, 5. Capacit 1.00 1.00 0.96 0.97 0.99 0.96 1.01 1.00 1.00 1.02 See notes on pg. 19. 18 Or Detailed cooling capacities* continued t Detailed cooling c CONDENSER ENTERING AIR TEMPERATURES F Itiplie ndoo Itisl cltie 80 F indo C). publ t kilo EVAPORATOR C CONDENSER ENTERING AIR TEMPERATURES F 85 9 95 1 105 1 115 wp m I N.CD Capacity T Total C Capacity T Total C Capacity T Total C Capacity T Total CFM M uht S System M MB uhf S System M MB uht S System M MB uhf S System Total S Sens$ K Kw** T Total Sens$ K Kw** T Total Sens$ K Kw ** T Total S Sens$ K Kw ** 38TKB060 O Outdoor S Section With C CD5AA060 I Indoor Section 63.8 3 31.3 5 5.62 6 60.9 3 30,3 6 6.17 5 57.9 2 29,2 6 6.77 5 54.8 2 28.0 7 7.41 1750 58.2 3 39.5 5 5,49 5 55.6 3 38.4 6 6.03 5 52.8 3 37.3 6 6.62 4 49.9 3 36.1 7 7.23 50.5 5 50.5 5 5.31 4 48.6 4 48.6 5 5.85 4 46.6 4 46.6 6 6.42 4 44.1 4 44.1 7 7.02 72 6 65.0 3 32.7 5 5.75 6 62.0 3 31.6 6 6.30 5 58.8 3 30.5 6 6.90 5 55.6 2 29.3 7 7.55 2000 6 67 5 59.4 4 41.8 5 5.61 5 56.6 4 40.7 6 6.15 5 53.7 3 39.5 6 6.75 5 50.7 3 38.3 7 7.37 57 5 52.4 5 52.4 5 5.45 5 50.4 5 50.4 6 6.00 4 48.3 4 48.3 6 6.58 4 45.9 4 45.9 7 7.19 72 6 65.5 3 33.4 5 5.81 6 62.4 3 32.3 6 6.36 5 59.2 3 31.1 6 6.97 5 55.9 3 30.0 7 7.62 2125 6 67 5 59.8 4 43.0 5 5,67 5 57,0 4 41.8 6 6.22 5 54.0 4 40.6 6 6.81 5 51.0 3 39.5 7 7.43 57 5 53.3 5 53.3 5 5.52 5 51,2 5 51.2 6 6.07 4 49.0 4 49.0 6 6,66 4 46.6 4 46.6 7 7.27 72 6 65.9 3 34.0 5 5.87 6 62.8 3 32,9 6 6.43 5 59.6 3 31.8 7 7.03 5 56.2 3 30.6 7 7.68 2250 6 67 6 60.2 4 44.1 5 5.73 5 57.3 4 42.9 6 6.28 5 54.3 4 41.7 6 6.87 5 51.3 4 40.6 7 7.50 57 5 54.1 5 54.1 5 5.59 5 51,9 5 51.9 6 6.14 4 49.7 4 49.7 6 6.73 4 47,3 4 47.3 7 7,34 Multipliers for Determining the Performance With Other Indoor Sections indoor Cooling Section Size Capacity Power Section Size Capacity Power CD5AA 060 1.00 1.00 FG3AAA 060 0.99 1.00 CC5A /CD5AW 060 1.00 1.00 FK4ANF 006 1,01 0.97 CC5A /CD5AA 060 0.96 0.97 28RDS /RNS 057 0,95 0,98 CA5A/CB5AA 060 0.97 0.97 061 1.00 1.00 CA5A /CB5AW 060 0.99 0.99 28RH 060 0.95 0,98 CD3AA 060 0.96 0.97 28SLS 061 1.01 0.99 CE3AA 060 1.01 0.99 4OLT 060 0.97 0.99 FB5AN(A,F) 060 1.00 1.03 40YR /YR(U,M,F,G) 060 0,97 1.01 FB4AN(A,M,F) 060 1.00 1.03 40YA /YAM 060 1.01 1.03 FB4AN(M,F) 070 1.02 1,01 40YZM 006 1.01 0.97 Coo ing Size Capacity Power 048 0.99 1.00 060 1.03 1.01 005 1.03 1.00 148 0,98 0.99 248 0.99 1.00 057 ' 1.00 1.00 061 1.02 1.01 048 0.98 0.99 060 1.00 1.00 048 0.98 0.99 049 1.00 1.00 061 1,05 1.01 048 0.98 0.99 060 1.01 1.00 048 0,99 1.00 060 1.02 1.05 048 1.02 1.02 060 1.03 1.03 005 1.02 1.00, 006 1.03 1.00 ridocr Section city ht Sens$ 24.6 31.5 38.0 39.1 25.1 32.5 39.1 39.8 Total System Kw" 5.65 5.51 5,37 5.34 5.70 5.56 5,43 5.40 Total 45,9 41.7 37.9 37.4 46.2 42.1 38.3 38.0 46.5 42.3 38.6 38.6 23.6 30,6 36.8 37.4 24.2 31.5 37.8 38.0 24,7 32.4 38,6 38,6 6.17 6.01 5.86 5,84 6.23 6.07 5,92 5.91 ERATURES F 25.7 33,4 40.1 40.4 idoor Sections 5.76 5.61 5,48 5.47 Capacity MBtuht Total System Kw** 6.28 6.12 5.98 5.97 Detailed cooling capacities* continued *Detailed cooling capacities are based on Indoor and outdoor unit at the same elevation and connected by 25 ft (7.62m) of tubing. If other than 25 ft (7.62m) of tubing is used and /or indoor unit is located above outdoor unit, a slight variation in capacity may occur. frotal and sensible capacities are net capacities. Blower motor heat has been subtracted. $Sensible capacities shown are based on 80 F (27 C) entering air at the indoor coil. For sensible capacities at other than 80 F (27 C), deduct 835 Btuh (245 kw) per 1000 cfm (480 US) of indoor coil air for each degree below 80 F (27 C), or add 835 Btuh (245 kw) per 1000 cfm (480 US) of indoor coil air per degree above 80 F (27 C). When the required data falls between the published data, interpolation may be performed. **Unit kw Is total of indoor and outdoor unit kilowatts. ridocr Section city ht Sens$ 24.6 31.5 38.0 39.1 25.1 32.5 39.1 39.8 Total System Kw" 5.65 5.51 5,37 5.34 5.70 5.56 5,43 5.40 Total 45,9 41.7 37.9 37.4 46.2 42.1 38.3 38.0 46.5 42.3 38.6 38.6 23.6 30,6 36.8 37.4 24.2 31.5 37.8 38.0 24,7 32.4 38,6 38,6 6.17 6.01 5.86 5,84 6.23 6.07 5,92 5.91 ERATURES F 25.7 33,4 40.1 40.4 idoor Sections 5.76 5.61 5,48 5.47 Capacity MBtuht Total System Kw** 6.28 6.12 5.98 5.97 Detailed cooling capacities* continued *Detailed cooling capacities are based on Indoor and outdoor unit at the same elevation and connected by 25 ft (7.62m) of tubing. If other than 25 ft (7.62m) of tubing is used and /or indoor unit is located above outdoor unit, a slight variation in capacity may occur. frotal and sensible capacities are net capacities. Blower motor heat has been subtracted. $Sensible capacities shown are based on 80 F (27 C) entering air at the indoor coil. For sensible capacities at other than 80 F (27 C), deduct 835 Btuh (245 kw) per 1000 cfm (480 US) of indoor coil air for each degree below 80 F (27 C), or add 835 Btuh (245 kw) per 1000 cfm (480 US) of indoor coil air per degree above 80 F (27 C). When the required data falls between the published data, interpolation may be performed. **Unit kw Is total of indoor and outdoor unit kilowatts. Matched system Book Tab AIR CONDITIONER 6 ./. C I. La AIM 0 AIR FLOW ELECTRONIC AIR CLEANER FURNACE • AIR VENT` PIPE HUMIDIFIER C_ 0 0 II GAS -FIRED WATER HEATER A89380 System Design 1. Intended for outdoor installation with free air Inlet and outlet. Outdoor fan external static pressure available Is less than 0.01 In. water column. 2. Minimum outdoor operating air temperature without low - ambient operation accessory is 55 F (12.8 C). 3. Maximum outdoor operating air temperature is 125 F (51.7 C). 4. For reliable operation, unit should be level In all horizontal planes. 5. Maximum elevation of indoor coil above or below base of outdoor unit is: Indoor coil above = 50 ft, Indoor coil below = 150 ft. (See items 6 and 7 following). 6. For Interconnecting refrigerant tube lengths greater than 50 ft, consult Long-Line Application Guideline available from equipment distributor. 7. Crankcase heater required when interconnecting refrigerant tube length exceeds 50 ft. This applies to units with reciprocating compressor. 8. Not more than 36 in. of refrigerant tube should be burled In the ground. If necessary to bury tubes under a sidewalk, provide a minimum 6•in, vertical rise to the valve connections at the unit. 9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. 10. Mismatches of Indoor coil capacity more than one size larger than outdoor unit capacity may result In inadequate Indoor comfort. TECHNOLOGIES Carrier Corporation • Syracuse, New York 13221 9 -91 """` CARRIER Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. 1 2 4 Page 20 Catalog No. 523.832 Printed In U.S.A. PC 101 Form 38TKB -2PD 3a la2a l Replaces: 38TKB -1 PD • • ME•IINGIL COOLING Product Data 4OYA,YR Direct Expansion Fan Coil Sizes 018 thru 060 40YA—The Technology of Air Handling I •iiiYA fin it ,-, oil unit. Idlest in nt Ilip,Irptk. It s to 111 , 1E1 Ilfi(11 of ,I111)1;( iii f inst,111,ition Iiittli h pcifonwit)t l• .1()Y,\ ,lyttlitINI' III ' I I MI I I I 1.'" 11 1 Mt 1, Iii, 01, , 1 1 ( I 1( t■ t ■11.( )()I 11,11, in c t ,,,I11 1 ,1, Crtipit OM! t i ijith (111(1 h■)11,'()10,11 111-4,11k:11 01 1. .)( N. It',1(1‘, t Iii light '0,11■'Ic III/0(1 If 1111/ !lit onsuw t'',iI 1 riit1,10(1 service, owl it's Oh' most components so Cntt Ilit)w tloilitf perfoini ,t tittlire ton coil should vt,i(11 find qt coppt!r tuft' loncet1 sine ■k.(1■..k) fin. ' ffi(u'titR " I Hill ■111(1 tip ...-,‘,11(1 stow cot,liriq controls iticItidt)(1 with •vt eocll tertnitiol ho,trd for use with ,tii iii cicanor litintitlificr lust kt..iie (lirectiv thi. tt flu' It to,litiics ;tote of the ,tit TXV lieirmenint Metering Itu Ii tfrill ft the outtl tor 11110 in the split sk Cdnier toclmolutlt,' oh-4) shines out hoclunitoil coil. tledicototi iefrittttront circnittv, tiitl hiqh densitt., in Awl, tot 1,1't. simple iirts, the , II)YA .1.■..'411 0)1111■'t11011', (1111.1 '1()YA offers superior ver with its 3 spockl twit nil 'wow! poclioqes foct,,ic ot hid(' iitstollet.1, the ,irt. ,1%.(111,thlt. :i it :itt l:■■•. fused 4(IVA !{-q1 with a circuit breaker, or non -fused for 10 -kw and less. Carrier engineered the 40YA with a filter rack to accept bulk media. This permits the homeowner to easily remove and clean the permanent filter supplied with unit —no tools required. 40YR Fan Coil —Air Handling Technology at its Finest • Efficient and dependable metering 2 WA • Features 40YA • Grooved copper tube • Lanced sine wave aluminum fin • Prepainted galvanized sheet metal • Cooling controls with every unit • Boehmited coil • 3 -speed motors • Plastic (with brass drain connection inserts) condensate pans • All units multipoise •. Modular versions 3 -1/2 -5 ton sizes • Factory supplied cleanable filter and filter rack • Easy access filter for cleaning—no tools required • Field or factory installed heater packages 3 -30 kw, fused, circuit breaker, non -fused (10 kw & down) • Solid state interlock control board • High density insulation. • Sweat connections • Bi -flow hard shut -off TXV • Multiple electric entry • Secondary drain connection • Connections for humidifier & electric air cleaner on low- voltage terminal board • Connections for electronic air cleaner on control module • Inspection plate for cleaning • 1 -1/2 -5 ton sizes • HUD approved for manufactured housing • Replaceable 5 amp blade -type auto fuse protects against transformer secondary short. • 40VA, 208 -, 230 -volt transformer of the refrigerant is provided by our A a device which improves overall system reliability and is easily accessible for piston changeout and routine maintenance. Carrier also engineered the 40YR with a boehmited coil, dedicated refrigerant circuitry, and high density insulation. Application versatility relies on Carrier's 3 -speed motor with field or factory installed heater packages. Our heater packages are available from 3- to 30 -kw, either fused or with a circuit breaker, or non -fused for 10 -kw and less. Illk ompact and attractive with a low - maintenance, easy -to -clean permanent filter, the 40YR is a favorite among homeowners. Just consider the first -cost affordability and Carrier performance and it's easy to see why. Features 40YR • Grooved copper tube • Lanced sine wave aluminum fin • Prepainted galvanized sheet metal • Cooling controls with every unit • Boehmited coil • 3 -speed motors • Plastic (with brass drain connection inserts) condensate pans • All units multipoise • Modular versions 3 -1/2 -5 ton sizes • Factory supplied cleanable filter • Easy access filter for cleaning • Field or factory installed heater packages 3 -30 kw, fused, circuit breaker, non -fused (10 kw & down) • Solid state interlock control board • High density insulation • Sweat connections • AccuRaterT" piston • Multiple electric entry • Secondary drain connection • Connections for humidifier & electric air cleaner on low - voltage terminal board • Connections for electronic air . cleaner on control module • Inspection plate for cleaning • 1 -1/2 -5 ton sizes • HUD approved for manufactured housing • Replaceable 5 amp blade -type auto fuse protects against transformer secondary short. • 40VA, 208•, 230 -volt transformer. Model number It VA—Direct Expansion Fan Coil YR— Direct Expansion Fan Coil Physical data OPER. WT. 94 REFRIGERANT Ref rig. Metering Device COIL Rows and Fins Per In. Face Area (Sq Ft) 2.23 Configuration Slope FAN Air Discharge Cfm (Nominal) Motor Hp (PSC) FILTER 21 -1/2 x 13 OPER. WT. REFRIGERANT Ref rig. Metering Device COIL Rows and Fins Per In. Face Area (Sq Ft) Configuration FAN Air Discharge CFM (Nominal) Motor Hp (PSC) FILTER *Modular Units HEATER KW 3 5 8 10 15 20 24 30 9 15 18 40YR — — Single Piece Cabinet M — Modular Cabinet Nominal Cooling Capacity 018 — 18,000 Btuh 042 — 42,0 024 — 24,000 Btuh 048 — 48,0 030 — 30,000 Btuh 060 — 60,0 036 — 36,000 Btuh 3 and 11 650 1/5 94 2 and 14 2.23 Slope 650 1/5 21.1/2 x 13 EL REFRIGERANT Refrig. Metering Device R -22 TXV COIL Rows and Fins Per In. 3 and 11 3 and 11 3 and 11 3 and 14 3 and 14 3 and 11 3 and 11/ 3 and 14 Face Area (Sq Ft) 2.23 2.97 3.46 4.45 4.45 5.93 5.93/7.42 Configuration Slope "A" "A" "A" "A" "A" "A" FAN Alr Discharge Cfm (Nominal) Motor Hp (PSC) 650 1/5 850 1/4 Upflow, 1100 1/3 Downflow, Horizontal 1300 1/3 1500 1/2 1700 3/4 2000 3/4 FILTER 21 -112 x 13 21.1/2 x 13 21 -1/2 x 16 -3 /0 21.1/2 x 16 -3/8 21 -1/2 x 18.7/8 21 -1/2 x 18 -7/8 21 -1/2 x 23.5/16 REFRIGERANT Refrig. Metering Device R -22 Bypass AccuRaterT" COIL Rows and Fins Per In. 2 and 14 3 and 11 2 and 14 3 and 11 2 and 14 3 and 11 3 and 11 Face Area (Sq Ft) 2.23 2.23 3.46 2.97 4.45 4.45 5.93 Configuration Slope Slope "A" Slope "A" "A" "A" FAN Air Discharge CFM (Nominal) Motor Hp (PSC) 650 1/5 850 1/4 Upflow, 1100 1/3 Downflow, Horizontal 1300 1/3 1500 1/2 1700 3/4 2000 3/4 FILTER 21 -1/2 x 13 21 -1/2 x 13 21 -1/2 x 16 -3 /8 21.1/2 x 16 -3/8 21 -1/2 x 18.7/8 21.1/2 x 18.7/8 21 -1/2 x 23.5/16 HEATER KW PHASE FUSES OTY /SIZE CKT. BKR. OTY /SIZE 3 1 — 2/60 5 1 — 2/60 8 1 — 2/60 10 1 — 2/60 15 1 2/30, 2/60 4/60 20 1 4/60 4/60 24 3/1 6 /60 — 30 3/1 6/60 — 9 3 — — 15 3 — — 18 3 — — our Ilkompact and attractive with a low - roves maintenance, easy -to -clean asily permanent filter, the 40YR is a and favorite among homeowners. Just o consider the first -cost affordability and Carrier performance and it's easy to erant see why. tion. n Id or s. Our om 3- circuit and Features 40YR • Grooved copper tube • Lanced sine wave aluminum fin • Prepainted galvanized sheet metal • Cooling controls with every unit • Boehmited coil • 3 -speed motors • Plastic (with brass drain connection inserts) condensate pans • All units multipoise • Modular versions 3 -1/2 -5 ton sizes • Factory supplied cleanable filter • Easy access filter for cleaning • Field or factory installed heater packages 3 -30 kw, fused, circuit breaker, non -fused (10 kw & down) • Solid state interlock control board • High density insulation • Sweat connections • A piston • Multiple electric entry • Secondary drain connection • Connections for humidifier & electric air cleaner on low - voltage terminal board • Connections for electronic air cleaner on control module • inspection plate for cleaning • 1 -1/2 -5 ton sizes • HUD approved for manufactured housing • Replaceable 5 amp blade -type auto fuse protects against transformer secondary short. • 40VA, 208 -, 230 -volt transformer Model number nomenclature YA— Direct Expansion Fan Coil YR— Direct Expansion Fan Coil Physical data OPER. WT. OPER. WT. *Modular Units — — Single Piece Cabinet M — Modular Cabinet 40YR — 018 Nominal Cooling Capacity 018 — 18,000 Btuh 042 — 42,000 Btuh 024 — 24,000 Btuh 048 — 48,000 Btuh 030 — 30,000 Btuh 060 — 60,000 Btuh 036 — 36,000 Btuh 94 94 98 98 126 126 128 128 Electrical 3 — 208/230 -1 147 147 ELECTRIC HEATER INTERNAL PROTECTION 158 158 0 Heater Kw D -5 J -15 S -8 L -20 G -10 Electrical Protection A —Fused C —No Protection D— Circuit Breaker 168 µ ynrr� <.r1_• } �; t ax, , 168 3 ITEM KW @ 240V FAN COIL SIZE USED WITH ACCESSORY P/N* 40YA 40YR 2 -Speed Relay Kit 40YA•900 -35101 All All Time Delay -off Relay Kit 40YA -900 -36101 All All Disconnect Kit 40YA•900 -37101 Cooling controls and heaters thru 10-kw Latent Capacity Control Kit 40YA -900 -38101 All All Down!low Base Kit 40YA- 900 -01101 018,024 018,024 40YA -900 -39101 030,036 030,036 40YA -900 -40101 042,048 042,048 40YA- 900 -41101 060 — Downflow Conversion Kit 40YA -900• -02101 018 018,024,036 40YA•900 -48101 024,030,036 — 40YA- 900 -49101 042,048,060 042,048,060 Filter Cage Kit 40YA -900 -42101 018,024 018,024 40YA•900 -- -43101 030,036 030,036 40YA -900- -44101 042,048 042,048,060 Sweat to Mechanical Adapter Kit 40YA•900 -45101 018 018 40YA- 900 -46101 024,030,036 024,030,036 40YA -900 -47101 042,048,060 042,048,060 Return Air Duct - Flange Kit 40YA -900 -00101 All All Single -Point Wiring Kit 40FS -900 -21201 All All HEATER P/N KW @ 240V VOLTS /PH INTERNAL CIRCUIT PROTECTION FAN COIL SIZE USED WITH HEATING CAP,t @ 230V 40YA900030 3 230/1 None ** 018,024 9420 40YA900050 5 230/1 018 thru 036 15700 40YA900080 8 230/1 042 thru 060 25100 40YA900100 10 230/1 018 thru 060 31400 40YA900150 15 024 thru 060 47100 40YA900200 20 030 thru 060 62800 40YA900300 9 None 036 thru 060 28300 40YA900310 15 None 036 thru 060 47100 40YA900320 18 None 042,048,060 56500 40YA900250 25 Fuses 048,060 78500 40YA900260 30 Fuses 048,060 94200 40YA900040 3 Ckt Bkr$ 018, 024 9420 40YA900060 5 " Ckt Bkr$ 018 thru 036 15700 40YA900090 8 Ckt Bkr$ 024, 030, 036 25100 40YA900110 10 non Ckt Bkr$ 024 thru 060 31400 40YA900160 15 0.0 47100 40YA900210 20 060 62800 40YA900170 15 47100 40YA900220 20 . 62800 40YA900270 048 060 78500 40YA900280 Fused$ 048,060 94200 W § 6 a f 40 N 0 LL CS o FA 7 I I 1 1 1 1 1 I 3 NO Ia0 H A W g $ 2 _ R a $ $ $ 0 LS a a i 0 o I I I I I I I I 1 1 1 1 1 1 1 1 1 � t z � c3 a 0 t 0 t 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I 5 N O 0 t 0 I CO 1 I I I 1 I 1 I I t 0 ut O 0 1. e g I I I I I I I I m, N co N N CI C1 N Y1 N a 7 b 0. a 0 0 0) al 0 0 o w a m 1 1 1 .o ^ 01 0 0 0 0 a 0 0 • P. I I 1 Si N 0 0 S S N A 'A m o 0 c 0 0 § a a 8 s Carrier Accessories *Factory•authorized and listed, field installed Accessory electric heaters 4 •T h eat er s fi conve to s ph ase. tBlower motor heat not Included. $CSA approved ELECTRIC HEATERS • • t 4 1 1 I 1 1 1 1 I I E ACCESSORY HEATER P/N 40YA900030 KW PHASE 1 INTERNAL CIRCUIT PROTECTION - HEATER SWGLE CIRCUIT 10.9/12.0 APPS 204230 -V DUAL CIRCUIT 11,12 - 13,14 - BRANCH CIRCUIT INN SINGLE CIRCUIT 162/17.5 AMPACITYt 208230 -V DUAL CIRCUIT 11,12 - 13.14 - YIN WIRE 208/230-V SINGLE CIRCUIT 12 SIZE (AWG) DUAL CIRCUIT 11,12 - 13,14 - MIN GND 2081230 SINGLE CIRCUIT 12 WIRE SIZE -V DUAL CIRCUIT 11,12 - 13,14 - FUSE/CKT 2087230 SINGLE CIRCUIT 20 BKR AMPS -V DUAL CIRCUIT MAX WIRE LENGTH•• FOR 2% VOLTAGE DROP 2081230-V SINGLE CIRCUIT 63/65 (FT) DUAL 112 - CIRCUIT L3 L4 - 240-V 3 204-V 23 L1,12 - 1.3,14 - 40YA900040 3 2.3 1 CB 10.9112.0 - - 162/17.5 - - 12 - - 12 - - 20 - - 63/65 - - 40YA9000S0 5 32 1 - 18.120.0 - - 26.7/19.0 - - 10 - - 10 IIIIII - 25040 - - 61162 - - 40YA900090 5 3.8 1 C8 18.1720.0 - - 26.729.0 - - 10 - - 10 - - 25/30 - - 61/62 - - 40YA9000S0 8 6 1 - 28.9732.0 - - 43.0/46.9 - - 8 - - 10 - - 4550 - - 61/62 - - 40YA400090 8 6 1 CB 289732.0 - - 43.0746.9 - - 8 - - 10 - - 45/50 - - 61/62 - - 40YA100300 9 6.8 3 - 18.8/20.8 - - 30.4/329 - - 8 - - 10 - - 35/35 - - 1081111 - - 40YA900100 10 7.5 1 - 362/40.0 - - 522/56.9 - - 6 - - 10 a -- 60/60 - - 78/79 - - 40YA900110 10 7.5 1 CB 362/40.0 - - 52.2/56 3 - - 6 - - 10 - 60160 - - 78/79 - - 40YA900150 15 11.3 1 FUSE 542/59.9 362/40.0 18.1/20.0 74.7/81.8 52.2156.9 22.7725.0 4 6 10 8 10/1C 10110 80/90 60/60 25/25 86/87 78/79 78/79 401A900170 15 11.3 1 FUSES 542159.9 36.2/40.0 18.120.0 74.7/81.8 522/56.9 22.7250 4 6 10 8 10/10 10/10 80/90 60/60 25/25 86/87 78/79 78/79 40YA900160 15 113 1 CS - 362/400 18.120.0 - 522/56.9 22.7250 - 6 10 - 10/10 10/10 - 60/60 25/25 - 78779 78/79 40Y/4800311 15 11.3 3 - 31.3/342 - - 46.0502 - - 8/6 - - 10 - - 50/50 - - 71/112 - - 40YA900320 18 135 3 - 37.6/41.5 - - 53.9/58.8 - - 6 - - 10 - - 60160 - - 94/95 - - 40YA900200 20 15 1 FUSE 72.3/79.9 362/40.0 36.2/40.0 97.3/106.8 52.2/569 45.3/50.0 . 3/2 6 8 6 10/10 1210 100/110 60/60 50/50 84/106 78/79 58/58 401AII00220 20 15 1 FUSES 72.3/79.9 36.2/40.0 362/40.0 97.3/106.8 52.2/569 45.3 /50.0 3/2 6 8 6 10110 10/10 100/110 60 /60 50/50 84 /106 78/79 58/58 40YA900210 20 15 1 CE - 362/400 36.2/40.0 - 522/56.9 45.3/50.0 - 6 8 - 10/10 10/10 - 60/60 50/50 - 78/79 58/58 40YA900250 24 15 3 FUSE 50.1/554 - - 69.5/762 - - 4 - - 8 - - 70/80 - - 116/117 - - 24 18 1 FUSE 86.7/95.9 - - 116/127 - - 1 - - 6 - - 125/150 - - 112/113 - - 40YA900270 24 18 3 FUSEt 50.155.4 - - 695/762 - - 4 - - 8 -- 70/60 - - 116/117 - - 24 18 1 FUSEt 86.7/95.9 - - 116/127 - - 1 - - 6 - - 125/150 - - 112/113 - - 40YA/0C260 30 225 3 FUSE 62.6/592 -- - 852/93.4 - - 3 - - 8 - - 90/100 - - 120/121 - - 30 22.5 1 FU5 109.0/120.0 - - 143/157 - - 0/00 - - 6 - - 150/175 - - 114/145 - - 40YA900240 30 22.5 3 FUSES 62.6/692 - - 852193.4 • - - 3 - - 8 - - 90/100 - - 120/121 - - 30 22.5 1 FUSES 1092•120 0 - - 143/157 - - 0/00 - - 6 - - 150/175 - - 114/145 - - O A O 0 FIELD MULTI-POINT WIRING OF 24-and 30-110/ SINGLE PHASE v, V O 0 1D A O P 3 O m O1 8 O CO 01 0 0 8 0) co 8 A V O O CO A O 0 ✓ O O CO N O T N Z III 0 D o U) = N m S m CO O < A D D O A IV O A 09 0 O O N A O O O 0 CO 0) O CO O ELECTRIC HEATEh ,iECTRICAL DATA CB- Circuit Breaker :Includes blower motor amps of largest fan coil heater is used with. tCSA fused with single point wiring adapter. $Copper wire must be used. If other than uncoated (non - plated), 75 degree C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the National Electric Code (ANSI/NFPA 70). **Length shown is as measured one way along wire path between unit and service panel for a minimum 2% voltage drop. NOTE: The 24- and 30-kw heaters are convertible to single phase, single or multiple supply circuit. CO 0 D *. . A B C D E F a K ' ,j. try ''.i IN (mm) IN (mm) IN (mm) IN, (mm) IN, (mm) IN. (mm) IN. 322.3 IN. (nun) .i'Ly(r:;eif:a'; � Ilf.'d 42.11/16 1084,3 14 -5/16 363.5 12.7/18 316.0 - - 18-3/16 482.0 12.11/16 322.3 10-7/16 _(mm) 285.1 14-1/4 362,0 ilk r +:;: ° 42.11/16 1084.3 14-5/16 363.5 12.7/16 316.0 14-1/4 362,0 18-3/16 462.0 12.11/16 322.3 10-3/4 273.1 - - ` ( r -,; 42.11/16 1084.3 17-5/8 447.5 15.3/4 400.1 14-1/4 362.0 18-3/16 482.0 16 406.4 10-3/4 273.1 - - :tW a 49.5/8 1260.5 17-5/8 447.5 15.3/4 400.1 14.13/18 376.2 23-3/16 589.0 16 406.4 15-11/16 15-1/2 15-1/2 25.1/4 398.5 393.7 393.7 841.4 - 25 25 26 - 635 635 635 #` , ;,,- e. , ` 53.7/18 1357.3 21-1/8 536.5 19.1/4 489.0 14-15/16 379.4 27 27 685.8 685.8 830.3 19-1/2 19-1/2 23 495.3 495.3 584.2 Y s 7 . '" 53.7/18 1357.3 21-1/8 536.5 19-1/4 489.0 14.16/18 379.4 w5 , / 1 59-3/16 1503.4 24-11/16 627.0 22-3/4 577,9 17-13/16 452.4 32-11/16 A B C 0 E F 0 285.1 K IN (mm) IN. IN (mm) 462 0 12 1 322.3 10.7/18 11/16 1 3 14-5/16 363 5 12 318 0 - - 18.3/18 /- 4 '; '- ''` ' 1 42.11/16 S LL : : : : :' ;' 49-5/8 1084.3 1260.5 17-5/8 447.5 15-3/4 400.1 14-1/4 362,0 18.3116 462.0 18 406.4 10-3/4 273.1 17-5/8 447,5 15-3/4 400.1 - - 23-3/16 589.0 18 406.4 16.3/8 390.5 - - - A:, . • ,. 5.-.f 53-7/16 r '' 1357.3 21-1/8 536.5 19-1/4 489.0 14-15/16 379.4 27 685.8 685,8 19-1/2 19-1/2 495.3 495.3 15-1/2 154/2 393.7 393.7 26 25 635 635 ) , "'r 53-7/16 1357,3 21-1/8 638.5 19-1/4 489.0 14 -15116 379.4 27 53-7/16 1357.3 21-1/8 538.5 19.1/4 489.0 14.15/16 379.4 27 685.8 19-1/2 495.3 15-1/2 393.7 25 635 Dimensions • t'4 (47.8) +3'�e (23.8) 101 (49 2 eee1111M1 2Ye (66 7) (285.1) Y (19.1) B 5 141, (34.9) (127.0) OPENING F INLET AIR 'h D. (22.2) K.O. FOR LOW VOLTAGE CONTROL WIRING 1 (25 4) , 1352 , 2.0 (22.2, 27.8, 50.8 K.O.'S) FOR HIGH VOLTAGE POWER WIRING DISCONNECT OR CIRCUIT BRAKER LOCATION BLOWER, CONTROL & ELECTRIC HEATER ACCESS PANEL COIL ACCESS PANEL LIQUID LINE CONNECTION SUCTION LINE CONNECTION 63'16 (157.2) FILTER ACCESS PANEL (71.4 1014 (273.1) CONNECTION SIZES CONDENSATE DRAINS, SUCTION, 018 • 41 O.D. SWEAT, 024 THRU 036 • V4 O.D.SWEAT 042 THRU 060 Ve O.D. SWEAT LIQUID, 3'e O.D. SWEAT LIQUID LINE CONNECTION 4 ( 19.1) 91 • 235.0) SUCTION LINE CONNECTION SLOPE COIL DETAILS CONNECTION LOCATIONS SHOWN FOR UPFLOW OR HORZ. LEFT APPUCATIONS ALTERNATE '/e D. (22.2) K.O. FOR LOW VOLTAGE CONTROL WIRING INLET AIR LIQUID LINE CONNECTION SLOPE CO LS DOWNFLOW OR HORZ. RIGHT APPUCATIONS AND "A COILS DOWNFLOW APPLICATIONS 2/ (54.0) NOTE: MODULAR 1V. UNITS WILL (31.7) HAVE A TWO• PIECE CABINET +Vie I, (17.5) ..-10Vie (258.8) 1 (25.4) 22Vie- (560.4) 11 -• (279.4) OUTLET AIR ALTERNATE 'h , 1352 , 2.0 D. (22.2, 27.8, 50.8 K.O.'S) FOR HIGH VOLTAGE POWER WIRING OPPOSITE SIDE Vi 20V+e (31.7) (600.6) INLET AIR A90163 i 7/. (22.2) 3 K (MODULAR UNITS ONLY) N CO N N CO -4 w C) 74 (222) TYP.* m N N 9, N - 4 0 J V TO m N m UT io O, N V O CO O O, (127) TYP.• ( TYP.• CD ro f N C) N 3 3 O N 1/ (38.1) 2 3 3 PRIMARY DRAIN ' 1111 _ ID PRIMARY DRAIN (127) 14L TYP* (34.9) 314 E (79.4) HORIZONTAL LEFT SLOPE COIL INSTALL SPECIAL DAM FITTING (HORIZONTAL ONLY) HORIZONTAL LEFT A-COIL 1/ (38.1) 7 CO N N O 07 PRIMARY DRAIN SECONDARY DRAIN SECONDARY DRAIN (INSTALL SPECIAL 1 45s DAM FIRING) 4 6-0) TYP.* - ;its (7.9) TYP.* PRIMARY DRAIN (46.0) TYP.* N CO U, N N N co V cn C APPLICATION, AS SHIPPED SECONDARY DRAIN m N m O co N CO CO S 2456 (55.0) TYP 2 PLCS.) NOTES: 1. ALL CONDENSATE DRAIN CONNECTIONS % FP T. ' 2. HORIZONTAL MOUNT LOCATIONS - DIMPLES PROVIDED IN TOP PANEL. AND BACK OF :ABINEI IN CABINET BOTTOM. HOLES PROVIDED .136 -IN DIA. (3.45). HORIZONTAL HANGING HARDWARE TO BE FIELD SUPPLIED. (S9 (7-9) 2456 ** TYP.• (55.0) TYP. (2 PLACES)' APPLICATION, AS SHIPPED O O W CO CO CD N O _ CO A CO 0 N A W O A Ca Ca N CO CO N O CO tJ O ( AIRFLOW TIP. 3 3 3 3 Li t( • • 1/ (38.1) 3 ( UPFLOW SLOPE COIL 3+/e (79.4) 4 (120.7) UPFLOW A-COIL (11.1) TYP • (4 PLACES) 1 (25.4) TYP. (2 PLACES)* a 7 Ae 1G (11.1) 2% 3 (25.4) (66.7) (79.4) TYP. (4 PLACES)* (2 PLACES)* DOWNFLOW SLOPE COIL 7 /u (11.1) TIP. (4 PLACES)• 1 (25.4) TYP. (2 PLACES)* t_ 2 t3 (68.4) (76.2) A90165 3 ( 11 (38.1) SECONDARY DRAIN PRIMARY DRAIN 44 (120.7) 3 (79.4) PRIMARY DRAIN r . 7 A6 (11.1) TYP. (4 PLACES)* DOWNFLOW A-COIL 1�45e' ( TYP.• Li 1 (25.4) TIP. (2 PLACES)* 1'456 (46.0) TYP.* 24i6 (55.0) TYP. (2 PLACES)* 11 45e E(7.9) TYP.• (38.1) H SECONDARY DRAIN 456 �� TYP• SECONDARY DRAIN (INSTALL SPECIAL DAM FITTING) PRIMARY DRAIN 245e (74.6) 1% (34.9) D E APPLICATION. FIELD 0.029 0.044 0.019 0.021 0.033 Performance data Blower Motor Speed High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low 0.10 890 700 615 850 655 1290 1140 890 1520 1315 1115 1755 1555 1395 2025 1885 1600 2095 1855 0.20 830 860 585 865 810 630 1245 1085 875 1460 1280 1170 1680 1515 1345 1555 2225 2035 1825 External Static Pressure —In. we 0.30 785 625 550 915 810 755 600 1165 1035 855 1420 1255 1075 1835 1455 1315 1855 1750 1940 1820 1510 2145 1975 1780 0.40 725 570 510 750 695 560 1120 980 830 1355 1220 1050 1565 1400 1260 1760 1875 1450 2050 1900 1715 0.50 650 520 440 680 635 510 980 915 770 1290 1160 1010 1485 1330 1210 1675 1590 1400 1955 1825 1640 High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low 935 640 685 715 635 990 925 720 1300 1150 890 1520 1315 1115 1585 1400 1930 1825 1610 1840 875 600 940 880 705 1245 1105 875 1460 1280 1170 1365 1765 1860 1560 2250 2075 2185 2025 1815 815 560 890 835 675 1185 1050 855 1420 1255 1075 1670 1485 1330 1785 1700 1510 2115 1970 1785 750 590 515 830 785 640 1115 990 825 1355 1220 '1050 1600 1540 1430 1290 1710 1830 1445 2045 1915 1740 675 525 480 785 720 575 1035 930 775 1290 1160 1010 1525 1370 1230 1620 1550 1375 1975 1850 1685 *Dry coil at 230 volts. NOTE: Not recommended for use above 0.60 in. 8 AIR FLOW PERFORMANCE* 0.60 555 400 355 605 560 430 915 825 700 1215 1110 950 1360 1250 1575 1515 1345 1850 1715 1565 585 430 375 655 610 500 925 835 700 1215 1110 950 1425 1290 1525 1470 1290 1900 1785 1635 AIR DELIVERY PERFIA AT IN NOTE: Subtract the above pressure drop correc static pressure will be available for the du RFJD[�� • CERTIFICATION • LISTING • TESTING • INSPECTION 0.40 0.50 0.80 725 650 555 570 520 400 510 440 355 750 680 605 695 835 560 560 510 430 1120 980 915 980 915 825 830 770 700 1355 1290 1215 1220 1160 1110 1050 1010 950 1585 1485 1360 1400 1330 1250 1260 1210 - 1780 1675 1575 1675 1590 1615 1450 1400 1345 2050 1955 1850 1900 1825 1716 1715 1840 1585 750 675 585 ,_ 590 525 430 515 460 375 830 765 655 785 720 810 640 575 500 1115 1035 925 990 930 835 825 775 700 1355 1290 1215 1220 1160 1110 1050 1010 950 1600 1525 1425 1430 1370 1290 1290 1230 - 1710 1620 1525 1630 1550 1470 1445 1376 1290 2045 1975 1900 1915 1850 1785 1740 1685 1635 AIR DELIVERY PERFA[MANCE CORRECTION COMPONENT AISSURE DROP (INS. WC) AT INDICATED AIRFLOW (DRY TO WET COIL) 400 500 0.019 0.021 600 0.029 0.030 0.030 0.017 700 0.036 0.039 0.039 0.023 800 0.043 0.050 0.051 0.030 0.020 0.022 900 0.062 0.037 0.027 0.028 100 0.076 0.045 0.033 0.034 0.044 0.029 1100 0.040 0.040 0,053 0.036 1200 0.063 0.044 1300 0.072 0.049 1400 0.083 0.054 1200 0,029 0.044 1300 0.033 0.049 1400 0.036 0.054 0.039 0.023 1500 0.040 0,059 0.044 0.027 1600 0.043 0.065 0.051 0.030 1700 0.046 0.069 0.057 0.033 0.033 0.030 1800 0.063 0.036 0.036 1900 0.069 0.040 0.040 0.034 f 0.039 2000 0.077 0.044 0.044 0.044 2100 0.049 0.048 2200 0.053 0.051 NOTE: Subtract the above pressure drop corrections from unit airflow data when that component or condition is used. The remaining external static pressure will be available for the duct system. ill ao • CERT If I(.A I I(IN • I ■ti1■Nl. CFM CFM CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. 1500 0.093 0.059 2300 0.058 0.053 21 60 25 65 27 57 24 68 28 72 30 75 31 84 35 87 36 83 Performance datakontd See notes, bottom page 11. 10 COOLING CAPACITIES (MBtuh) • 2300 127 0.21 51 *Saturated suction leaving evaporator coil. Sensible Heat Capacity (1000 Btuh) BF Bypass Factor NOTES: 1, Gross capacities shown do not include a d fan motor heat. 2. Contact Carrier for cooling capacities at shown in table. 3. Formulas: sensible heat Leaving db = entering db - 1.09 x cf Leaving wb = wb corresponding to enth (hlwb) hiwb = howb' total capacity (Btuh) 4.5 x cfm where h = enthalpy of air entering coil. o..w. 1 E EVAPORATOR C COIL REFRIGERANT TEMPERATURE* (F) 35 40 45 I 50 Evaporator Air-Entering Wet Bulb Temp (F) 72 6 67 8 82 7 72 6 67 6 62 7 72 6 67 6 62 7 72 6 67 6 62 t o1 y 6 450 3 30 2 24 2 20 2 27 2 21 1 16 2 24 1 18 1 13 2 20 1 14 1 11 12 1 14 1 14 1 11 1 12 1 13 1 10 1 11 1 11 9 9 9 9 9 9 650 3 35 2 29 2 23 3 32 2 25 2 20 2 28 2 21 1 16 2 23 1 17 1 14 14 1 16 1 18 1 13 1 15 1 16 1 12 1 13 1 14 1 10 1 12 1 12 ,. 800 3 38 3 31 2 25 3 34 2 27 2 21 3 30 2 23 1 18 2 25 1 18 1 16 16 1 18 2 20 1 17 1 18 1 13 1 15 1 16 1 12 1 13 1 13 " k • 6 600 3 39 3 32 2 25 3 35 2 28 2 21 3 31 2 23 1 17 2 26 1 18 1 15 18 1 18 1 19 1 15 1 16 1 17 1 13 1 14 1 15 1 11 1 12 1 13 'o24 . • 8 875 4 47 3 38 3 31 4 42 3 34 2 26 3 37 2 28 2 22 3 31 2 22 1 19 - 19 2 22. 2 24 1 18 2 20 2 21 1 16 1 18 • 2 20 1 14 1 16 1 16 r. 1000 5 50 4 41 3 33 4 45 3 35 2 28 3 39 3 30 2 24 3 33 2 23 2 20 21 2 23 2 26 1 19 2 21 2 23 1 17 1 19 2 21 1 15 1 17 1 17 0 ‘ 1- 0 750 5 51 4 42 3 33 4 46 3 36 2 28 4 40 3 30 2 22 3 33 2 23 1 18 21 , 2 23 2 24 1 19 2 21 2 22 1 18 1 18 1 19 1 14 1 16 1 16 1075 6 60 4 49 3 39 5 54 4 43 3 33 4 47 3 36 2 27 3 38 2 28 2 23 25 2 28 3 30 2 23 2 25 2 27 2 20 2 23 2 23 1 17 2 20 2 20 k \., ' : 1 1250 6 65 5 52 4 42 5 58 4 45 3 35 5 50 3 38 2 29 4 41 2 29 2 25 27 V V 3 30 3 33 2 24 2 27 V V 2 29 2 22 2 24 2 26 1 19 2 21 2 22 .,14 , . .. 900 5 57 4 47 3 37 5 51 4 41 3 31 4 45 3 34 2 26 3 38 2 27 2 22 24 2 26 2 26 2 21 2 23 2 25 1 19 2 21 2 21 1 16 1 18 1 19 .. „. I ,..,4 4 1300 6 68 5 56 4 45 6 61 4 49 3 38 5 54 4 41 3 32 - 28 3 32 3 35 2 26 2 29 3 32 2 23 2 26 2 28 2 20 2 23 2 24 0 1 1500 7 72 5 59 4 48 6 65 5 52 4 41 5 57 4 43 3 35 4 48 3 34 3 31 30 3 34 • • 38 2 27 V V 31 3 34 V V VV 25 2 28 V V V 31 V 2 22 2 25 2 26 ,.• , , 1 1200 7 75 6 60 4 48 6 66 5 52 4 40 5 57 4 43 3 32 4 46 3 33 2 27 31 3 34 3 36 2 28 3 30 3 32 2 24 2 27 2 28 2 21 2 23 2 23 q, •, 1 1530 8 84 6 68 5 53 7 74 5 58 4 44 6 63 4 48 3 37 5 52 3 37 3 32 35 3 39 4 42 3 31 3 35 3 37 2 28 3 31 3 32 2 24 2 27 2 27 ,, , ' i 1400 8 83 6 67 5 53 7 74 5 58 4 45 6 64 4 49 3 37 5 53 3 38 3 32 34 3 37 4 40 3 31 3 34 3 38 2 27 3 30 3 32 2 24 2 26 2 27 1750 9 92 7 75 8 65 5 50 7 72 5 54 4 42 5 59 4 43 3 38 VV 4 42 4 46 ' V V V 34 ' ' 3 39 4 42 V V V 31 3 35 3 37 V V 27 3 30 V VV31 Ie. TEMPERATURE* (F) 1 45 1 , 50 r ng Wet Bulb Temp (F) 72 67 62 72 67 62 27 21 15 23 16 12 • - 11,, . .. 12 , ' .., -.1p - w:'...: , ,, , ::',10:: i'::','11,...!; 34 26 19 28 20 16 . 14 - . •• • 15 r: 16 , • '''. 4 ''. .."..',.., ''4.?":14. 38 29 22 31 23 19 t , - 16 • .' .; 18 - r , ', 19. ...,14, ' 34 26 19 29 20 16 .. 14 '• ••15' '..16 •:,:. 12.:.:': :::',•:. , ;: i..'203' . :i;:g, 42 32 24 35 25 20 18, . .: •.' 20 " . 21' . .... • -, 18 '; . V: :. •.,:44.0y.,:,`• 45 34 28 38 27 22 ' - 19 .• ' - 21 :.,. . 23 • ,"1-.1 7 .. :.: .. , . , ...Y.19.:,:';';; ) , 43 32 24 36 26 20 ..' 18 : ' • :19 : • -' ... 20 ' VV 15, .,.. . `,...17. '...,' 51 39 30 43 31 26 . 22 1 24 ' . 28 ' , -.19: .: ,'.,:•21. 55 42 33 46 34 28 • 24. f'. • . 27 ••. .. 28 .' .• • ' , ..723.:f . ...:, 24T; 52 40 30 44 32 25 : 22.' - • ;. •,'., -- '' ':...-.; ,, ::19,',• , : : , .';21.„, :,... •li'' I 61 47 37 52 38 32 5 .. 28 . :30 . • -.' 32 •.-:. •,".' •;•24.■.:•: V 27 ,.-;.•,,,' ;;28i,... 3 64 50 41 55 41 35 3 28 ''' 33 '.I 35 • '''25 •':.... V.r;9 ,.:, B 69 52 39 58 41 33 E5 V ' .29 ' , .32 "' 33 , , ' :. 25•:,...: •: 5 77 59 45 65 46 39 4 33 . 37 ' ' 39.; '. -, • 29. i:-: -, :.;:i. ;.',.•;43';c1 8 81 62 48 68 49 41 7 V • 35'. . ; 39' ' .. 42 ' • , , 31 ..•. V. , 34 .r.': 4 77 58 44 65 46 37 2 ' 32 . 35' . ": 37 : ', '' ••281,•....2. :',; :.:•: 1 87 66 50 72 51 43 8 . 37 - ' . 40 • ; . • - • 43. , , • : • 32; , , •" 35.. i.3T.Y„ 5 92 70 55 77 55 47 3 39 , ., :. 44 ' - ',.-... 47 .,•:-,' • ' ',' ; • 7 95 73 54 79 57 46 3 V 40 , • 44 :: • • 46 .,.., 35 , :;; 1 101 77 59 85 61 50 B , 43 ,'. 48 • , 51'.-- . . 38 :•.::. . , :;.5i:43,"•,:il 7 107 82 64 90 65 55 3 '• 47 ' 52V ' 55 , .•:• 4:1 , .,. "- 46 ';', tuh) • COOLING CAPACITIES (MBtuh) Co *Saturated suction leaving evaporator coil. " Sensible Heat Capacity (1000 Btuh) BF-Bypass Factor NOTES: 1. Gross capacities shown do not include a deduction for evaporator fan motor heat. 2. Contact Carrier for cooling capacities at conditions other than shown in table. 3. Formulas: sensible heat cap. BYPASS Leaving db = entering db - 1.09 x cfm FACTOR Leaving wb = wb corresponding to enthalpy of air leaving coil (tInvb) total capacity (Btuh) = hewb 4.5 x cfm where h = enthalpy of air entering coil. 4. Direct interpolation Is permissible. Do not extrapolate. 5. SHC is based on 80 F db temperature of air entering coil. Below 80 F db, subtract (corr factor x cfm) from SHC. 0.10 0.20 0.30 SHC CORRECTION FACTOR 79 • 81 0.98 0.87 0,76 ENTERING AIR DRY-BULB TEMP (F) 78 82.1 1.96 1.74 1.53 77 76 75 Under 75 83 V 84 84 Over 85 Correction Factor 2.94 2.62 2.29 3.92 3.49 3.05 Interpolation is permissible. Correction Factor = 1.09 x (1 - BF) x (db - 80) 4.91 4.36 3.82 Use formula shown below. 11 tuh) • COOLING CAPACITIES (MBtuh) Co *Saturated suction leaving evaporator coil. " Sensible Heat Capacity (1000 Btuh) BF-Bypass Factor NOTES: 1. Gross capacities shown do not include a deduction for evaporator fan motor heat. 2. Contact Carrier for cooling capacities at conditions other than shown in table. 3. Formulas: sensible heat cap. BYPASS Leaving db = entering db - 1.09 x cfm FACTOR Leaving wb = wb corresponding to enthalpy of air leaving coil (tInvb) total capacity (Btuh) = hewb 4.5 x cfm where h = enthalpy of air entering coil. 4. Direct interpolation Is permissible. Do not extrapolate. 5. SHC is based on 80 F db temperature of air entering coil. Below 80 F db, subtract (corr factor x cfm) from SHC. 0.10 0.20 0.30 SHC CORRECTION FACTOR 79 • 81 0.98 0.87 0,76 ENTERING AIR DRY-BULB TEMP (F) 78 82.1 1.96 1.74 1.53 77 76 75 Under 75 83 V 84 84 Over 85 Correction Factor 2.94 2.62 2.29 3.92 3.49 3.05 Interpolation is permissible. Correction Factor = 1.09 x (1 - BF) x (db - 80) 4.91 4.36 3.82 Use formula shown below. 11 Typical installation Carrier Corporation • - Syracuse, New York 13221 6-90 UNITED TECHNOLOGIES CARRIER Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without Incurring obligations. Book 1 I 4 Page 12 Catalog No. 624.038 Printed in U.S.A. PC 101 Form 40YA,YR•1PD Tab 3o 20 Replaces: 40YA,YR.1APD April 8, 1992 Dear Mr. Kraft: Sincerely, Ken Nelsen Plans Examiner C City of Tukwila 6200 Southcenter Boulevard • Tukwila, Washington 98188 John W. Rants, Mayor: Fenton Kraft. HVAC Manager 9404 East Marginal Way S. Seattle, WA 98108 a RE: Museum of Flight ( Challenger Center HVAC ) Plan check number M92 -0060 After a review of the subject project, it has been determined that the proposed Carrier air conditioning unit may "NOT" be located within the existing plenum system in accordance with U.M.C. Chapter 10. If information on an alternate unit or this one was provided to show its design and approval for an in plenum application, this denial could be reevaluated. Please confirm you have received this comment by contacting this office and /or submit revisions within ten working days. Feel free to call me if there are any questions, 8:30 a.m. to 4:30 p.m. at 431 - 3670. Phone: (206) 433-1800 • City Hall Fax (206) 433 -1833 F7= Update, F2= Previous Line, ESC = Cancel Update F1 =Help, ESC =Exit current screen. MECHANICAL PERMIT Activ •l Processing Tenant ` r f nt 'S8 . ; • Sage 2 DING 0 Address r 4O4 x ',. sr.v � l City • .Mc r } �' G . l / t� 4e �y ti bK' f. fg 78? 4" r a II^ _ . ` 4`YV.Ll G �, ::. City of Tukwil .. Type: B -MECH Vers: 9101 Screen: 01 4 0A204$$9thcenter Boulevard • Tukwila, Washington 98188 John W. Rants, Mayor SEUM OF FLIGHT FOUNDATIO By: SLB Plan Ck Approved: / / tatus: PENDING Applied: 3/31/1992 Issued: / / Active /Inactive: A Completed: ,,, . / x� /.��..� � pr To Expire � N^ L`� � n4 ' •trp Nature of Work: A;DD.?A►R' HADELING1aSY5 „' Eli %X ° Gi11T Location: ” k• Category: NRES (RES, NRES, STOV) Inspector Area: Valuation: 15,000.00 UMC Edition (Yr): 1988 Fire Protection: Use Change (Y /N): Storage of Flammable /Hazardous Materials:N /A CITY OF TUKWILA Id: ROUT130 Keyword: UACT User: 1677 04/16/92 Activity document routing maintenance. Permit No: M92 -0060 MECHANICAL PERMIT Route: 1 Current Route Line: 2 of 5 Packet Units Description Station Status Received Assigned Complete aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa Packet Units Action Station Initials Status Received Assigned Completed MECH 01 01 C FNLREV KEN Ap Cont. 03/31/92 04/16/92 04/16/92 Priority (0 /low..9 /high): 0 Comments 1 „��.�., a Hours t9 4r ,1l . H` �. 4r<r�..•;r.r,xx+flns�rt Regular hours (HH.MM : + •n - �+ - .: st., ef►. exu� !x GTe�'L ! i+' t% 2 ,., :l y uu: 41%,..1 u.r, iik 4lSh ... Sro f 3 . r 17 d = w y ett+i wo smr 9fPGPnv V'1 Yr y . 1F �rt�. x rn1 $ erro ...,•MMr o�y_ °r� 0 �.' f f e ' �� 4 [ � ' . 9 Ci � r1 rr +a^•;t� . •,, y �; � F1+ ' ",ly�(1� . ! .�., � . ` H « �� Q .. a O M e L r {i 4 fl 5 r 8[ ] 9[ ] 10[ ] aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa Phone: (206) 433-1800 • City Hall Fax (206) 433-1833 EXISTING RETURN AIR PLENUM • • CARRIER`38TK6O60 5 TON COND. UNIT 1/2 EMT EXISTING DUCT CENTERLINE ELEVATION 91' ABOVE CONDENSING UNIT SLAB • - EXISTING RETURN GRILL (TYP) 1265 CFM AT PRESENT REBALANCE TO 947 CFM LIQUID LINE FD ACCESS DOOR 24/12 GRILL SCALE - 1/4" = r i_ 10/10 rzircczFD> 48/4 tNEM SLOT CIFFUSEI 313 CFM HVAC PLAN 12/10 16/10 24/10 DUCT 22/24 AIR FILTER 1050 CFM 14/10 CONDENSATE LINE 3//4. SCH.-40 PVC SLOPE =.25 / FT FD ACCESS DOOR approvals are Check app royal of t .• i cithissionsa olatlon `of ai�Y on�erscand that the Plan sut) to s r riot i to the Receipt Of con= plans d C deto ordinance Ied9Qt' adopted c opy l o plans acKnow 1ractor'sC o app By bate p No. MUSEUM OF FLIGHT CHALLENGER LEARNING CENTER SEATTLE, WASHINGTON APPROVED FOR BID BY THE MUSEUM OF FUGHT JO8 NO. DRAWING 92-122 HVAC PLAN AHU ISOMETRIC SCALE NOTE: ALL FIELD INSTALLED POWER AND CONTROL WIRING LOCATED IN RETURN AIR PLENUM SHALL BE PLENUM RATED OR ENCLOSED WITHIN AN EMT CONDUIT ASSEMBLY NOTE: ALL REFRIGERANT` LINE INSULATION INSTALLED IN RETURN AIR PLENUM SHALL HIVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE DEVELOPING INDEX OF NOT MORE THAN 50 WHEN TESTED AS PER U.B.C. 42 -1 NOTE: CONDENSING UNIT CLEARANCE REQUIREMENTS 12' •MINIMUM SIDE. CLEARANCE 30' MINIMUM SERVICE ACCESS CLEARANCE EXISTING PLENUM WALLS, CEILING AND FLOOR: REINFORCED CONCRETE EXISTING 2d RETURN AIR DUCT CENTERLINE ELEVATION OF GRILL IS 91' ABOVE CONDENSING UNIT SLAB NOTE: DUCTS SHALL BE MINIMUM 26 GUAGE GALVANIZED` SHEET METAL PLENUMS SHALL BE MINIMUM 24 GUAGE GALVANIZED SHEET METAL REFRIGERANT LINES SHALL BE INSULATED AS PER MANUFACTURERS RECOMENDATIONS 3/4" EMT (LV CONTROL WIRING TO AHU & DDC SYSTEM) r EMT TO AHU & SERVICE PANEL SUCTION LINE 3/4'11P bX FAN COIL UNIT CARRIER 40YA060 OR EQUIV. 2000 CFM 0 0.45 IN.112O 20/14 AIR FILTER 953 CFM (MAKEUP AIR) TRAP AHU DISCONNECT 1 2 6 5 R1 (TYPICAL) 'NOTE: NOTE: 11 /C DISIGNATES LANDIS & GYR POWERS UNITARY CONTROLLER (UNIT PROGRAMED TO TEST PLENUM. TEMP. " AND ::SMOKE DETECTOR PRIOR TO ALLOWING STARTUP OF CONDENSING UNIT) EXISTING FD TO PANEL C 1 208V 30A 30 1 208V 20A 10 APPROV b p 1992 S m covED art 0v. TDlOw" SEP0 peRM� col° DATE SHEET SEPT. 1 1992