Loading...
HomeMy WebLinkAboutPermit M92-0070 - BOEING #21-01m92-0070 boeing #21-01 HVAC 3417 SOUTH 120TH PLACE ftEIkG AtoDw i I Ci o 7�Icwlll Address: 3417 S 120 PL Location: Parcel #: 102304 -9069 INSTALL 750..CFM EXHAUST FAN ON WALL. UMC Edition 988 MECHANICAL PERMIT Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M92 -0070 Status: ISSUED Type: B -MECH Issued: 04/29/1992 Category: NRES Expires: 10/26/1992 TENANT BOEING COMPANY #21 -01 Phone: 206 544 -2975 P.O. BOX 3707, M/S 46 -87, SEATTLE, WA 981242207 OWNER BOEING COMPANY Phone: 206 544 -2975 P.O. BOX 3707, M/S 46 -87, SEATTLE, WA 981242207 CONTRACTOR BOEING INC. Phone: 206 544 -2975 9725 EAST MARGINAL WY S, SEATTLE, WA 981242207 **********************************.*******.**** * * * * * * * * * ** * ** * * * * * ** ** * * * * * ** Permit Description • Valuation PermitFee:" • Date: (206) 4314670 500.00 26.88 ************'**, t******.********, 4************* * * * * * * * * * * * * * *. * * * * * * * * * * * * * * ** Permit Center Authorized Signature' .iDate I hereby certify that I have read and examin'ed'this permit and know the same tobe true : and correct. All`. provisions of law and ordinances governingthis work will be, complied with, whether specified herein or not. The granting of permit does not •presume. to give authority to violate or cancelthe provisions of any other state'or local laws regulating construct or the performance of work'. I am authorized to,sign: for and obtain that d ng perm Title: This permit shall become null and void if the work is not commenced within 180 days from the' of issuance, or if the work is suspended or abandoned for a period ' > of 180 days from the last inspection. PERMIT NO. CONTACTED DATE READY DATE NOTIFIED 2nd NOTIFICATION 3RD NOTIFICATION l I q ` I ) ,. BY: ~- � J � (init.) BY: ( init. ) P EXPIRES AMOUNT OWING _ MECHANIC'. PERMIT APPLICATION TRACKING PLAN CHECK NUMBER INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". DEPARTMENTAL REVIEW "X" In box indicates which departments need to review the project. ART BUILDING - initial review O FIRE O PLANNING O OTHER BUILDING - final raviaw REVIEW COMPLETED PROJECT NAME SITE ADDRESS �J c t INIT: INIT: Z% ctsz__._ OUTED INIT INIT: (�� 3Ltfl S lac CONSULTANT: FIRE PROTECTION: (l Sprinklers ( ) Detectors (1 N/A FIRE DEPT. LETTER DATED: ZONING: SCREENING REQUIRED? fYes f) No REFERENCE FILE NOS.: UMC EDITION (year): UIREME Date Sent Date Approved - SUITE NO. INSPECTOR: BAR/LAND USE CONDITIONS? )Yes No Oe,17 /e0 NEW 7 � •1i1L7:MEM1 "1' CR 'l IYPE OF WORK: JCNew /AdditIon 0 ModificatIons 0 Repair 0 Other: , BAS la PERMm•F . : : , , ' :•.TYPE . < : : . . : : . . . ; . . : . ; .:. .:; <•:: RATINGISIZE . .. ..., sU..:.:0<0=<<:? : NUMQ A'OF UN►Tgfe, .. UNITS)TEErit. . 440ig AVANit +/.00i'r i :+ '.r >.:: t;, : ...,Y PL'ANrC : );. rut. .,;.,r::22:; WILL THERE BE A CHANGE -IN USE? a No 0 Yes IF YES, EXPLAIN: `0 � +�., 1. Z '6iI" , : aC'. , � , S��:�.�� �: �t��� 4 .0sl6!Ik4I1 ,. �t.ic..<s' :',. t1,M!`�:`IY ?.��!yl 4(. MA;lfrFj;gN OW ft . TOTAI:Nk A ,t . IMMO K i > t;; A.: WS:::'s i ,. ,:• 4: '3ITE ADDRESS SUITE # ;3417 SO 120TH PL BLDG. #21 -01 VALUE OF CONSTRUCTION - $ 2,500:00 PROJECT NAME/TENANT :OE I NG MILITARY AIRPLANES IYPE OF WORK: JCNew /AdditIon 0 ModificatIons 0 Repair 0 Other: , DESCRIBE WORK TO BE DONE: INSTALL 750 CFM EXHAUST FAN ON WALL . : : , , ' :•.TYPE . < : : . . : : . . . ; . . : . ; .:. .:; <•:: RATINGISIZE . .. ..., sU..:.:0<0=<<:? : NUMQ A'OF UN►Tgfe, .. FAN MODEL #8A010 2HP/480V 1 BUILDING USE (office, warehouse, etc.) WAREHOUSE /MAFG NATURE OF BUSINESS: • t WILL THERE BE A CHANGE -IN USE? a No 0 Yes IF YES, EXPLAIN: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? i>No 0 Yes IF YES, EXPLAIN: PROPERTY OWNER, BOEING MILITARY AIRPLANES PHONE (206) 544 -2975 ADDRESS P.O.BOX 3707, MIS 46 -87, SEATTLE, WA. ZIP 98124 - 2207 CONTRACTOR BOEING MILITARY 'ATRP LL1F_ PHONE 1296) . `t44 -2979 ADDRESS P.O.BOX 1707. M/S 46 -8Z. SRAT'�Pr,R,Wp. ZIP (18174 1.72(17 WA. ST. CONTRACTOR'S LICENSE # BOF�NC - 2_3_1 EXP, DATE j)1 - 01 - 93 ARCHITECT :• ►• u e: e : • eel PHONE ( 206) 544 -2975 ADDRESS P.O. BOX 3707, M 46 -87, SEATTLE WA. . 1 ZI'P 9R1 24 - 2707 H 1„ RE Y'; s . :: N NN tl�S B, . RTI HA:. < 1 • 1 . ' p'ANt3.: I . .; 1 P •C' , p ., ?THIw ` . ... r,' <.• : ' . � a '' >" �A+ t• . $4 y 7` v: N�i k (: '•k ! >ti ;;k pvt : C : (' •• .T UE >ANb�sC;O IJ:tI..A :.AUT ` • �7Ft1Z ... D` ° � . . � :,. �`, ;�: � , fi •k r•< > , � r �:.,Y. � � ,,:•:;a � i,•:1 � .,� . F� ► ;`�At`1 . N4 }M E .F I7 . '.RL.. F•CI `EH`' !� 1>F' .,�,�t �:�f�c.�<�;,.��;���';:�. ,tit.: !�'�. xr. >�:a:..y..,. t :. BUILDING OWNER OR AUTHORIZED AGENT SIGNATURE / - e.ey t;c DATE APRIL 20, 1992 PRINT NAME .' • PHONE (206) 544.73975 CITY /ZIP x$124 - 2207 PHONE (206) 544 -2975 ADDRESS P.O. BOX 3707, M/S 46 -87, SEATTLE,WA. CONTACT PERSON TERRY BENNETT CITY OF TUKWILA Department of Community Development - Building, 6200 Southcenter Boulevard, Tukwila WA 98188 (206) 433-1849 PAXTON JOB 41910976 -01 PLAN CHECK NUMBER Cra r � O�I � APPLICATION MUST BE FILLED OUT COMPLETELY MECHANI .-AL PERMIT APPLICATION , ,iPPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. • A completed "Mechanical Permit Fee Worksheet" must accompany this permit application. Handouts are available at the Building counter which provide more detailed Information on application and plan submittal requirements. Application and ufa►W5'must it t:ti'riuuitite' in'Yridbi' iu'Le ac eoted for plan review. 3UILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. /ALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure Is used for budget 'reporting purposes only and not to calculate your fees. XPIRATION OF PLAN REVIEW Applications for which no permit is Issued within 180 days following the dale of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined In Section 304(d) of the Uniform Mechanical Code (current edition), No application shall be extended more than once. 11 you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 433-1849. DATE APPLICATION A CEPTED DATE APPLICATION EXPIRES Mechanical Fee Worksheet must also be filled out and attached to this llcation, FEES (for stall use only) ** k* k***• kk **•k ** * k *kk** *kkk** ***** *k*****k *hkk ****kk* *kk*•kkk*Ait CITY OF. TUKWILA, WA.. TRANSMIT ***** * * * *k* * ** *k * *k * * * * * * *k * *k ** fir ** * * ***k * * **h.4**k * * * * ** * ** *fir * ** TRANSMIT Number: 9200037 1. Amount: 26.88 04/29/92 13:55 Permit Nc: M92-0070 Type: B-MCCH MECHANICAL PERMIT. Parcel • No: 10.1304- 9069 „: 04/29/92 Site ,Address L. 3417 S' 120 PL Payment Method:. CASH . ' Notation BOEING lnit : SLB fi k k* k******* *************•******* ** * * *** * * ** **** * * * *k **** Account Code :•Descriptian '.: Paid 000/34.5.830 `” PLAN CHECK - NONRES 5.38 000/322.100 ' :; MECHANICAL -. NONRES 21;50. Total ( Payment): 26.88 •'GENERA GENERA • TOTAL CASH CHANGE:: 9372000 12 :52 5.38 21.50 26.88 26.88 0.00 Total .Feels: All Payments: Hal ance: 26.88 26.88 .00. Address: Tenant: Type: Parcel #: 3417 S 120 PL BOEING COMPANY #21-01 . B -MECH 102304 -9069 CITY OF TUKWILA Permit No: M92 -0070 Status: ISSUED Applied: 04/23/1992 Issued: 04/29/1992 ************************* * * * ** * * * **** * * * * *** *** *** * * *• *** * *•kYk*.A ** * * **** ** ** Permit Conditions: . 1. No changes will be made to the•plans unless approved by the Architect and the Tukwlla Building Division. 2• Electrical .permit shall be obta.i n.e.d..,,t,hrough the Washington State Division work will be ins of :Labo ,46:d, Ind.u �a;rn;d; electrical ected b' - t"ha't� a nc '' " • ' p Yr gency .. <27:?';;- 7'272,? 3. All :permits, • insp �c.ti-afi records, and -' tans shall be maintained av f''`a"b%1'e•at he obb sit'e) approve'd. t�he'?s of :an do -" ° ' ' y �t�on�': o Tl` r e�e�c�'c��bu ^mei.n�t•s� ere, to ;�b m a int°'a1,na,d available un f, nal i nspect i on K apprd l i ;gi st grant�tech:. :. 4 :Readi1y ae�ssib.1et,a'c,cess to'�•roof mo'u'nted edu �lp m ent is�? required 4 ,� � t . » ` r 'a • s ,Ath ' a t i V s 0 ;=r ' r 5 Any' ex d :i n 1 o ns b ack`1ng' k m � at.eria1 sha h a ,Fla Spread• pi .'e of'' 2�i less 'and m ,t'erial shallobe'ar d dent ficati pit showing ,the fir rating thef „eof. r r ,.: 6. 'Ali 4 istiru i on{: t , ber „done i`ri ; conformance with 'approved p 1a ft nd* nr.,e� u i �r, " e men ts: Y U n - i fo rm • Bu i i d i ng Code' 8` Edi f I`On) f ands the Unifo'r'm M th e.,ch 3t ni�;.Code (1988'Edit on) { (198 i, ;; ,.� 7. Va1, ty�o"f�rPermit 'The >iss a ce of ,a enm, t .or approval o 1 fi 'spec �. s''and °4 � �� cal h��, x a i e c Y ,k. u p , ,� ,on cq pia4 i sl; 44 not .be., con: st rr �'d to 5e 2i ' °•fo 5 , -..,,t a'n' " p'`roval of� any viola`t,i'onl of a A y gof the � provi�s'ions o "his c e,�or of any other', i . o d1 ance, of the `' ur.i,s!di;ctthn No 'p .emit- p=ns.•of resuming to g�•i�•v'eli' o or• viola ;t e o ic e of- i:6 �de�, the�,prov.� is i=o ?this .code 3 au t, s ha t i• be v a,1 i d a, Anse ` �' ; ¢.. � � ..�, ti .. FROM BMAC FACILITIES Labor and Industries Electrical Section PaFMlt3 a oWNrn • 6t t:CipIPAL CONTRA0To PAEMISES ADORERS PITY AR6Ab NUT INSPECTED OR APPROVED: 1.12.1993 14129 D O N O T t M • V! ❑ Unfinished Basement ❑ Garage /Pu4 House ❑ Unfinished Upet re ❑ , z7(3 . 6 FHA 00.6414 I.tpretan MpoIt ►u •10ri 4 1.116 6 S P. 2 ELEU rRICA '' COTDII N) INSPECTION RtiPORT Vert 6fectrical 124&6645 rtment of labor & Industries Gateway Drive le, WA 98168 -3311 N9 614986 COMMENTS: ' • 'type of inspection: f /N'/1Z ,4-PPt2-AV/fc -- /-� co,„-,--7,61,74,--- on -,--7, } (.4 'o J Pic, vl a /Ai 9 lg-dli ot" Et c r.l cr►t.. r-Lt. Ai m - c1 .. f 4 3) - . 3t (,$ . Spedal Instructions: Lo \ i r '-t- an d `C e r(1 W l 11 tY1.Q e J, p u . Date Wanted: P a -ail= - r€,\W tI rz1Rz vtA f----m , S€L ctae 0 -q3(x)11. R m. Requester: Phone No.: I -' (- Project: . , ' a • * ` , a I 'type of inspection: . t Spedal Instructions: Lo \ i r '-t- an d `C e r(1 W l 11 tY1.Q e J, p u . Date Wanted: I -q3(x)11. R m. Requester: Phone No.: .� -' (- INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Inspector: PERMIT NO. (206) 431 -3670 Approved per applicable codes. Corrections required prior to approval. Date: / /Z . `j D $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILLA WASHINGTON 98105 VICINITY MAP AREA MAP GENERAL NOTES DRAWING INDEX %/ Q FROM DOWNTOWN SEATTLE '// KING COUNTY AIRPORT QFICE ❑ i -Ot ` n CENTER ( FAA ) BLDG. p BLDG. 21 —01 ADDRESS: 3417 SO. 120TH PLACE TUKWIL WA. _ (EAST MA I \ V I N A L WAY CORPORATE PARK) CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. VERIFY ALL DIMENSIONS PRIOR TO START OF CONSTRUCTION. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRED DESIGN REVISIONS. REVISIONS TO BE APPROVED BY CITY OF TUKWILA PRIOR TO PROCEEDING WITH PROPOSED REVISED WORK DRAWING NO. SHEET NO. TITLE DRAWING No. SHEET No. TITLE 21 -01 -A1 Al TITLE SHEET 121-001-1000 A5 ARCHITECTURAL MASTER - PLAN 72P911210 1 CALCULATION SHEET Q 900 / \ AX �0 �. %y 9y= 0 � , o 1 . �' i .° //e y 99 "" EXIT - -- r — I -- I —� PROJECT SITE _.- — y l i �\ 121 -02 — PROJECT CHECKLIST I 121 -01 CHECK ® BRIEF PROJECT NARRATIVE — f I , , 1 — L 21 1 — 03 I �� ADD Tx 26' FENCED AREA AT COLUMN LINES E F/8 WITH 3' 4 "x 15' x T 6" HIGH ELECTRICAL SWITCHBOARDS INSIDE. IT INCLUDES AN 8 "x 12" WIDE WALL PENETRATION & A 2' -6 "x -0" DEEP DUCTBANK THAT GOES OUT UNDER THE FOOTING AS WELL AS ELECTRICAL CONDUCTOR SUPPORTS. ® THESE DRAWINGS CONFORM TO THE 1988 U.B.C., U.F.C., U.P.C., AND THE 1990 BARRIER FREE CODE AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. ® COMPLETE BUILDING FLOOR PLAN SHOWNG EXITING SYSTEM, DOORS, CORRIDORS AND PASSAGEWAYS. ❑ ENGINEERING CALCULATIONS (IF APPLICABLE) ® NUMBER O N PRIN FOR AREA OF CONSTRUCTION. ❑ ::::::: NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: ❑ 1. GENERAL PERMIT (SHELL Sc CORE) 2 SETS OF CIVIL DRAWINGS 6 SETS OF ENERGY CALCULATIONS WITH UTILITIES 2 SETS SOILS REPORTS, STAMPED BY GEOTECHNICAL ENGINEER 2 SETS STRUCTURAL CALCULATIONS 2 SETS PROJECT CONSTRUCTION SPECIFICATIONS 2 SETS TOPOGRAPHICAL SURVEY 2 COPIES OF LEGAL DESCRIPTION 2 SETS OF WORKING DRAWINGS ® 2 TENANT IMPROVEMENTS, 2 COMPLETE SETS ❑ 3. MECHANICAL, 2 COMPLETE SETS ❑ 4. FIRE PROTECTION /SPRINKLERS, 2 COMPLETE SETS C 0 D E S U M M A R Y t O I ' \ OXBOW LOT d S S � �' ACCESSRO No j% Q' BOEING LAND USE CODE M - HP CODE REFERENCES 198$ UBC KING COUNTY / TUKWILA WASHINGTON STATE ENERGY CODE WASHINGTON STATE BARRIER FEE CODE ADDITIONS PER CITY OF TUKWILLA ` I L � OCCUPANCY GROUP B -2 OFFICE, NO CHANGE IN OCCUPANCY TYPE V 1HR SPRINKLER 3 _ i EXIT 1 — / j j \ I 121— 05 j II CONSTRUCTION FEET SIDES) LOCATION ON PROPERTY SEPARATION 90 (3 FLOOR AREA (ACTUAL) BUILDING FOOTPRINT 98,000 SF PROJECT AREA 180 SF BUILDING HEIGHT: 26' 5 1/2" FLOOR TO PLATE - . '''''''' 1r7 L ill I , STORIES: 1 2 (OFFICE) ' % EXIT 5? li OCCUPANT LOAD: PROTECTIONS FULLY AUTOMATIC, VET PIPE THROUGHOUT � '\ I I I - � � FIRE till' - - -- I \ -- II I \ � I I I i � \ , - - =_= L -- ,\ SEISMIC ZONE 3 FIRE ZONE 3 599 EAST MARGINAL WAY TUKWILA,,. CORPORATE PARK 99`1 FROM KENT 900 &AUBURN NOTE: MECHANICAL AND ELECTRICAL PERMITS ARE TO BE SUBMITTED SEPARATLY FROM THIS PACKAGE. � FILE COPY ' � L {f �1F �CC� ro '' T t\D � "``{ � aaRlferSand than the Plan eck pp royal of �R' sub (ect<°errorsandomissChionsanadapp ��1RE aeos does not authorise the Re leipi °oft a ° ^v 4� , h1 p• ,� code a oTdi arce Erac?or'soo?Y °f a ° p�i a. crowle •} � rl ;) `a D �� �- r, l , A3',' Oo � � p Im Kw l� , , I c1 APR 2 3 1$9 _ . .., ,,:h .. Pe No. PERMR _ = i \ \, \ ` � \ \\ , \\ ® II I i) N0 SCALE ` EAST MARGINAL WAY CORPORATE PARK FROM SEATTLE- TACOMA AIRPORT • PROJECT SITE r O II (f 'Ilk NO SCALE DEVELOPMENTAL CENTER Sn TAA AA BY APPROVED DATE sn REEIS�ON BY APPROVED DATE AUBURN, WA. 98002 �/ ❑ KENT, WA, 98031 � EVERETT, WA. 98201 �� ®� ®,® ®� FAf I1 ITIFC CIF IDARTAAPNT ,—� —,--- --. ..... .... ACCEPTABILI TB15 DESIOry AND/OR SPEgFICATOry IS APPROVEa DRA BY EDDIE P. DUARTE DATE t2 -13 -91 SUB TI TL E TITLE SHEET r �A 'ION � sn aa. us kC aA y''T Al __ .._ a ...1) A UPGRADE ELECTRICAL SER ACE 191 0905 -01 B. PETERSON 2 -13 -91 1 E ROR. W.E. PETERSON 2 -13 -91 T SR - .. - ., , . rr . r, ■ r • • • rr r APPRO E O BY DEP r. OA E I 't �,.. E,..�„ 100 AUX AIR DUXT UP TO SFMA1 800 CFM CONNECT TO FUME HOOD 10 0 EXH DUCT UP TO MEZZANINE 1200CFM • CONNECT FUME HOOD 600 CFM (TYP 2 PLCS) SEE DETAIL 1M1OJM50 400 CFM (TYP 2 PLCS) SEE DETAIL 1MIOJM501 1000 CFM 625 CFM (TYP 2 PLCS) REFG.PIPING RE /ISIO U CUTA1B ISSUE FOR CONSTRUCTION MAKE -UP AIR COLA /1 #900614 -01 750 CFM EXH. FAN, COLA /1 910976 -01 1M10 Hill MJC PAX TON PAXTON CU1A1B IM10 lM11 i 24'x 24'! 11)(AHMA (AHMA1B) BY APPROVED DATE SEE ARCH.DRAWINGS FOR CONC. PAD DETAILS 5000 CFM 22X19 DUCT UP EFIA1- 5600CFM /4 0 UP THRU ROOF SEE DETAIL 1M10 RELIEF AIR W /AUTOMATIC BACKDRAFT DAMPER (TYP 8 PLCS) rhci2 ano 0.04.90 149z- REVISION RELIEF AIR W /AU i OMATIC BACKDRAFT DAMPER SEE DETAIL 1M10 M500 (TYP.3EAJ FIRST FLOOR PLAN APPROVED RELIEF AIR W /ADJUSTABLE BACKDRAFT DAMPER 770 CFM (TYP 5 PLCS) DATE 8'0 FLUE THRU ROOF SEE DETAIL \ 1M10 M500 L ✓ ❑ AUBURN, WA. 98002 ❑ BELLEVUE, WA. 98007 ® ®E /Akin ❑ EVERETT, WA. 98201 FACILITIES DEPARTMENT ❑ KENT, WA. 98031 ❑ PERT! ANTI. f1R. 97 ? ?0 8'0 FLUE THRU ROOF SEE DETAIL \ 1M10 M501 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY L�r DEPT. DATE En JOB N0.910976 -01 CONSTRUCTION NOTES: INSTALL NEW 750 CFM AIRFLOW SYSTEMS WALL MOUNTED EXHAUST FAN IN CHEMICAL MIX ROOM OF TECHNOLOGY LAB (MODEL 80010). TOP OF FAN UNIT TO BE I' BELOW CHEMICAL ROOM CEILING. CORE DRILL 6' EXHAUST HOLE THROUGH EXTERIOR WALL. (DO NOT HAMMER DRILL HOLE). SEE STRUCTUAL DESIGN FOR DRILLING INSTRUCTIONS). INSTALL A 20 GAGE RAIN COVER OVER OUTSIDE OF HOLE. PAINT TO MATCH EXTERIOR WALL. COVER OPENING WITH BIRD WIRE. CONNECT (8' DIA x 10' LONG) HOSE DUCT TO FAN AND EXTEND TO LOCATION ON NEW COMPOSITE LAY UP MACHINE AS INSTRUCTED BY EQUIPMENT ENGINEERING. KEY PLAN RECEIVED CITY OF TUKW ILA APR 2 3 1392 PERMIT CENTER HVAC PLAN - FIRST FLOOR MECHANICAL_ MASTER BE &C ENGINEERS LAST REVISION SHEET SYMBOL