HomeMy WebLinkAboutPermit M92-0128 - LABEL SCOTTm92-0128 label scott hvac 4222 south 146th street Nt3EL ScoTT City of TakwilL C. Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M92 -0128 Type: B -MECH Category: RES Address: 4222 S 146 ST Location: Parcel #: 004000 -0470 Contractor License No: GMMECC *113BT TENANT OWNER CONTRACTOR Signature : Print Name: MECHANICAL PERMIT LABEL SCOTT B 4222 S 146TH ST, TUKWILA WA 98168 LABEL SCOTT B 4222 S 146TH ST, TUKWILA WA 98168 G & M MECHANICAL.. CONTRACTORS P.O. BOX 6147, KENT, WA 98064 • ********************************************* * * * * * * * * * * *. * * * * * * * * * * * * * * * * * ** Permit Description,: INSTALL GAS FURNACE AND DUCTWORK., UMC Edition: i988 Valuation: Total Permit Fee: ********* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** _.�.�. _c __ 1LQ __!Sx Permit Center Authorized Signature Date I hereby.'cer„tify that I have read.and exam this permit and know the same to.b,e true,and correct.. All provisions of law and ordinances, governing this work will be complied with, whether specified herein :Or not. The granting of this permit does not presume to authority to violate or cancel ..the provisions of any other state or local laws regulating construction or the performance of work., I ` am authorized to sign:for and obtain this building per it. Date: (206) 431 -3670 Status: ISSUED Issued: 07/06/1992 Expires: 01/02/1993 Phone: (206)243 -4725 Phone: (206)243 -4725 Phone: 206 630 -1932 , 000.00 41.25 /J2 Title: Of' / /i'Iy�V it? This permit shall.become null and :void . i.f'the work is not commenced within 180 days from the date of issuance, or if`;,the work is ; su'spended or abandoned for a period_of• 180 days ; f r om the: last inspec't'ion. PERMIT NO. CONTACTED ---- r\ DATE READY DATE NOTIFIED �c -- a I Q BY: (init.) • PERMIT EXPIRES 2nd NOTIFICATION 3RD NOTIFICATION BY: (init.) BY: init. AMOUNT OWING t , `�1 C PLAN CHECK NUMBER 'mqa o ia5b REVIEW COMPLETED PROJECT NAME MECHANIC/Y. .PERMIT APPLICATION TRACKING (---Ost>21 3co E (can SITE ADDRESS SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. ARTMEN ` ABUILDING - - initial review O FIRE O PLANNING O OTHER RO TED) INIT: INIT: INIT: — I B /C? UILDING - final review I ICI rt_ INIT: UIREM _.__ .... CONSULTANT: Date Sent - Date Approved - FIRE PROTECTION: (l Sprinklers () Detectors N/A FIRE DEPT. LETTER DATED: INSPECTOR: ZONING: IBAR/LAND USE CONDITIONS? ( )Yes (I No SCREENING REQUIRED? fYes ll No REFERENCE FILE NOS.: UMC EDITION (year): 1c 7 -- (S C I \1\13E•_ C PROPERTY OWNER ,S -T .qL S,1440 ti A A d,,-4_ PHONE , p ., 2, _ 9J.3 ADDRESS 44.g2_ S / i -6 T, sr_'�-i T/� / 4.)/41 j- ZIP 5�-/ r,- CONTRACTOR 6- i ,,, t ",/ iz- h!4 44 G G ('6r�</Q/IG ,-„<5 PHONE 03 rl c 3 ADDRESS / 41a Brit 7 / ---'-,7 41 zip , 9k 6 6,9 WA. ST. CONTRACTOR'S LICENSE NSE # 6� ,,,,.. cG 11 3 i 3 EXP. DATE _ 9 !::DESCRIPTION:::::' ;;< .. > «AMOUNT:: :: RCPT : # ?: €::::;:DATE =;? BASIC "PERMIT<!FEE? ..!<< >< `' '15 00N::: : :> < >!> > » ? i; < « > >' ' _«> PLAN:: CHECK OTHER :< >: ;:: ......;TOTAL' - ;: >:. ::: , .. CITY OF TUKWILA f Department of Community Development - Building 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK NUMBER _ APPLICATION MUST BE FILLED OUT COMPLETELY SITE ADDRESS NATURE OF BUSINESS: SUITE # �'R24 S, �ylc S r PROJECT NAME/TENANT sc S714,QoA- TYPE OF WORK: Zi New /Addition 0 Modifications 0 Repair 0 Other: DESCRIBE WORK TO BE DONE: /c/7 - FA r ) BUILDING USE (office, warehouse, etc.) WILL THERE BE A CHANGE IN USE? (53;No 0 Yes IF YES, EXPLAIN: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? 1 No 0 Yes IF YES, EXPLAIN: BUILDING OWNER OR AUTHORIZED AGENT CONTACT PERSON "jc,(1- DATE APPLICATION ACCEPTED MECHAN CAL PERMIT APPLICATION Division Mechanical Fee Worksheet must also be filled out and attached to this application. VALUE OF CONSTRUCTION - $ FEES (for staff use only) 3 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. A completed "Mechanical Permit Fee Worksheet" must accompany this permit application. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 431 -3670. DATE APPLICATION EXPIRES 08/18/90 SUI6nAITTAL CHECKLIST MECHANICAL E' Completed mechanical permit application (one for each structure or tenant) Two (2) sets of mechanical plans, which include: • Floor plan • System layout • Elevations (for roof mounted equipment) • Heat Loss Calculations n Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) Note: Hood and duct systems require a building permit for the duct shaft DESCRIPTION UNIT COST UNITS X COST BASIC FEE $15.00 SUPPLEMENT PERMIT FEE $4.50 1 installation or relocation of each forced -air gravity -type furnace or burner, including ducts and vents attached to such appliance, up to and including 100,000 Btu /h. $9.00 l X 2 Installation or relocation of each forced -air or gravity -type furnace or burner, including ducts and vents attached to such appliance over 100,000 Btu /h. $11.00 x 3 Installation or relocation of each floor furnace, including vent. $9.00 x 4 Installation or relocation of each suspended heater, recessed wall heater or floor- mounted unit heater. $9.00 X 5 Installation, relocation or replacement of each appliance vent installed and not included in an appliance permit. $4 f I X 6 Repair of, alteration of, or addition to each heating appliance, refrigeration unit, cooling unit, absorption unit, or each heating, cooling, absorption, or evaporative cooling system, Including installation of controls regulated by this code. $9.00 X 7 Installation or relocation of each boiler or compressor to and including three horsepower, or each absorption system to and including 100,000 Btu /h. $9,00 X 8 Installation or relocation of each boiler or compressor over three horsepower to and including 15 horsepower, or each absorption system over 100,000 Btu /h and including 500,000 Btu /h. $16.50 X 9 Installation or relocation of each boiler or compressor over 15 horsepower to and including 30 horsepower, or each absorption system over 500,000 Btu /h to and including 1,750,000 Btu /h. $22.50 X 10 Installation or relocation of each boiler or compressor over 30 horsepower to and including 50 horsepower, or for each absorption system over 1,000,000 Btu /h to and including 1,750,000 Btu /h. $33.50 x 11 Installation or relocation of each boiler or refrigeration compressor over 50 horsepower, or each absorption system over 1,750,000 Btu /h. $56.00 X 12 Each air - handling unit to and including 10,000 cubic feet per minute, including ducts attached thereto. (NOTE: This fee shall not apply to an air - handling unit which is a portion of a factory- assembled appliance, cooling unit, evaporative cooler or absorption unit for which a permit is required elsewhere in this code.) $6.50 X 13 Each air - handling unit over 10,000 cfm. $11.00 X 14 Each evaporative cooler other than a portable type. $6.50 X 15 Each ventilation fan connected to a single duct. $4.50 6 X 16 Each ventilation system which is not a portion of any heating or air - conditioning system authorized by a permit. $6.50 X 17 installation of each hood which is served by mechanical exhaust, including the ducts for such hood. $6.50 X 18 Installation or relocation of each commercial or industrial -type incinerator. $1 1,00 X 19 Installation or relocation of each commercial or industrial - type incinerator. $45.00 X 20 Each appliance or piece of equipment regulated by the code but not classed in other appliance categories, or for which no other fee Is listed in this code. $6.50 X 06/16/90 SUBTOTAL PLAN CHECK FEE (ubt tip) GRAND TOTAL $ CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 THIS WORKSHEET MUST ACCOMPANY YOUR MECHANICAL PERMIT APPLICATION. MECHANr: ;AL PERMIT FEE WORKSHEET INSTRUCTI Complete the worksheet, Ind icatin g the number'of un,ts being installed in each;category. At time p subm ttal, ;staff : will calculate the.;f *** k******************* Ar * * *** * *,**** *A* ***** * **** *FF **A ********k CITY OF TUKWILA,,WA TRANSMIT * kkk**** k*******F**********• kF******** k * *k * * * *** *FFkk *•k,kkk* ** TRANSMIT Number: 92000681 Amount: 41.25 07/06/92 11:02 Permit Not M92-0128 Type: 0 -MECH MECHANICAL PERMIT Parcel No: 004000-0470 � 07/06/92 ... Site .Address: ';4222 S 146 ST Payment ` Method: CHECK Natation : :0 & M "MECHANICAL. in t: SL0 ** kk***** k******* k Frk* FF * * * * * * * * *?k *>k* * * * * *k * *F *fir * *r* *•k * ;.. Account : Code Descr i pt i on Pa i d 000/345.830 PLAN CHECK - RES 8.23. 000/322.100 . MECHANICAL REa.. 33.00 Total (This Paymennt)z 41.25 GENERA 8.25 GENERA . 33. 00 TOTAL , 41.25 CHECK 41.25 CHANGE..; Q.00 12A000, 09 :57 Address: 4222 S 146 ST Tenant: LABEL SCOTT B Type: B -MECH Parcel #: 004000 -0470 CITY OF TUKWILA Permit No: M92 -0128 Status: ISSUED Applied: 06/25/1992 Issued: 07/06/1992 * * * ** *** * * **•k ** *`kit * * * * * * *`k * *** ** * * * ** k***** ** * * ** * * * *** * * * * ** * * * **•k* ** ** Permit Conditions: 1: No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obta..i ne.d-.- through the Seattle -King County Department of Public F ea „th u °'Plum inspected by that agency..; �•l nc l�ud i ng all "' ' p',i;p (296 -4722) . ,s�,4,"`. � (1 A . Electrical pe,r� . t�;rshall b'e l hroug ,thea'Was�h State Divis �, ;o'f 'Lab �and If,ndus•t�ri'es and aIyelect ical work will 'b...ey;p tnspecte�d by that age - (277 72F72 }•:; °� �4 ti A J '�°i - �T1�v, fFn +sr h �i M , ��r ,,� �' t. 4. All permi inspecn re and' approved ,,p, �l 1, be maintai dr'avai leble at the job site prioP *to the sta•� of, any con st) uct ` 4 These doc`u e�nt are to be 'main'ta1ne,d ��•� ,t u V nti i''fi al ins O e tiion V ap rova l is r �� ` �;; a ; ,' .:; n � , � !� p� tl �c Pp: s g rya n t'e �% • 5. Any a d insula tiona�cking material shall Wave a �Frl''ame, avai l Spret d,'t R a€4,ng of..25 or Mess, \any ,.naterial shall bear .dents fic ,L rsh�owin,.y the ft"e per rating thereof.`' 6. A11 ' nstruction to b'e "pdone.,0 conformance with approvedj p p1a 4 andAwequOremept'of this' Unif.c *TT8c Code x(1988 Ed ,t'1+on), Uniform le,chanii }al Cod C'•i988fE,dition), and, t h.r;,w,._ Wa h ; ngton �,St,at '-•.Ener`gy Cocd'e (1E:991�. Ed• ,,1 a1 }, 7. MA NU�AcTURERS, I STALLATiON,i ��VSTRUCTI Ns. REQUIRED ON ?7:: ,,,,,, FOt ; HE BUILDING iNSPECTO EVIE r 8.. 7.6,'04j3 Cap MAXIMUM" ALLO WED P R '991-WASHINGTON STATE 'R w..o n �a.. i' �• . .,, . E N E'R COD e„ . ;>> •4„. N ,•!«t ' ">+ ',�x. q , $ {) Ua 1 : � t,�� �f:�Pe�mi t . The i ssuanc� >>�af .,a p,�rm- i't,�.�or app� pl a , s�.pee f� i delt i ons and comput d o `q^ n _ a i ndt be m 9. f stri.4 \to b '% permit for, or an pproue l\ of;• any 4 q i a of an, ',' f 4' pro isions of this ode o ' „a o ther "thzy.•u `'ordin ^ y Q of the Y� risdiction, qo p rser t Or g f t m1i''ng to giv r 1a . autho '� Nor v • 01 a t e,} ,� r cancel me pro +v n:�' h i .:� , cad � shall be id sl '' ? ( 1v iAQh 4 ' — Project: / E Type of lnspediorF n,t..... Address: 44,a z ce s. 1 41D S; , Date Called: Special Instructions: Date Wanted: J — = 93 art p .m. Requester: — c-ecin Phone No.: • INSPEC1 RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIV \SION 6300 Southcenter Blvd., #100, Tukwila) WA 98188 (206) 431 -3670 ved per applicable codes. ❑ Corrections required prior to approval. re ❑ $30.00 REINSPECTION EE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt Date: Project: L c ...4 a / / T of Inspection: , Address /42,2a Sl s, in ec"4 Date Callod: R9 /, —4;"t: Special Instructions: f , Date Wanted: 61-4 y--' m. am,p,m. Requester: Phone No.: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ❑ Approved per applicable codes. Ins pector: 'INS,PE TION REORD, Retain a copy with permit PERMIT No (206) 431 -3670 Corrections required prior to approval. Date ❑ $30.00 REINSPECTION FEE REbUIRED, Prior to reinspection; fee must be paid at 6300 Southcenter Blvd., Suite 100.: Call to schedule reinspection. 1 Receipt No,: Dale: COMMENTS: ypeo ns'» : . clevol if ri Address: a a qa a s• /go"' st . . I OdtAh- c.)r- 1 S MISS/MG (I) g 6. iSTEA Z- ?t- .1 ri<-71,,i ri /...6 CA41 NJ OF A 'NJ F.K.eisH a-1 K. 3 3) rilAyi !A IA n1 /ft LOVit• •Art& 1 i 74t, 0 V 0t),,... t -1 Ai.t. 8/, az70. P L 648E Co t.Ji"wc-1- e e- Ar 03 J- 3 IP 7 7 A I hit) 6 1i-. Rzvet-t— , 1 4) DO , x) Y )2.--S 0 F-F-4 OE: 1 5 ini 1 5 5 r MC., A , I 0 1 't 0 11..t i 1 4 it- IN) ii i2 . p .......,,---- .................. ro Kt ,. rn Mechan:cr ypeo ns'» : . clevol if ri Address: a a qa a s• /go"' st ikte Called: 74(0 Special Instructions: , • . . Date Wanted: 7/7 am, p.m. Requeste tffin r La ri Ph_oneslo.: 6, 30..Lit.2szk__ Inspector: 0. INSPECTION RECORD ' Retain a copy with perm CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Date: 7A / 1 , 2._ 0: (206) 431-3670 Ei Approved per applicable codes. Corrections required prior to approval. .'" • 0 $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Slab on grade / Floor perimeter insulation None (F= .81 ) 37.3/LF BTU R -5 (F= .61 ) 28.1/LF LF BTU R -8 (F= .56 ) 25.8/LF LF BTU R -10 (F= .54 ) 24.8/LF 106 LF 2629 BTU Infiltra- tion Pre 1980 (.018x1.2ach) 1.0 /CF CF BTU Post 1990 .018x.35ach) .29 /CF 27480 CF 7969 BTU Heat Loss. D14ct Loss Outside air 160 cfm x 1.018 x 46 DT = Total Heat Loss. Minimum Allowed Equipment Size (THL x 1.) Maximum Allowed E.ui ment Size (THL x1.5 Equipment: R eem RGLG1OEB Outside air requirement per WSEC 1991 27480 cu.ft. x .35 / 60 = 160 cfm mininum FILE. COPY .'...... -' . approvals are and ro? sa1 of al understand that end o missions a ;any s.ublect to errors and - ize the vial ?tin ° Plans C1065 not author C-ieuE " ;�, of con- or ordinance on- • a cto ' code . o f approved anss tractor's co gy D e Permit No. 1\1\1‘1161 CyN5 q Page 2 1�. to output A.F.U.E. 80.0% 39275 BTU 3928 BTU 7492 BTU 50695 BTU , TU 76043 BTU gas furnace Building component Description including U value or F value Heat Loss Factor (HLF =U N 46 DT) Component Square Ft Linear Ft Cubic Ft Component Heat loss (HLF x SF, LF or. CF) Window Skylight Sliding Glass Door Single (U =1.20 ) 55.2/SF SF BTU Double (U= .90 ) 41.4 /SF SF BTU (U= .75 ) 34.5/SF SF BTU (U= .60 ) 27.6 SF 552 SF • 15235 BTU Other. (U= .32 ) 14.7 /SF SF BTU Opaque Door Wood (U= .40 ) 18.4 /SF 60 SF 1104 BTU W /storm (U= .28 ) 12.9/SF SF BTU Insul Metal (U =.20 ) 9.2 SF SF BTU Roof/ Ceiling Insulation None (U= .40 ) 18.4/SF SF BTU R -11 (U= .075) 3.5 /SF SF BTU R -30 (U= .036) 1.7 /SF 2147 SF 3650 BTU R -38 (U= .031) 1.4 /SF SF BTU R -49 (U= .020) .9 /SF SF BTU Wall Insulation above and below grade None ((.1= .25 ) 11.5/SF SF BTU R -11 (U= .08 ) 3.7 /SF SF BTU R -19 (U= .057) 2.7 /SF 2396 SF 6469 BTU R -27 (U= .037) 1.7 /SF SF BTU Floor over unheated space • . None (U= .25 ) 11..5/SF SF BTU R -11 (U= .08 ) 3.7 /SF SF BTU R -19 (U= .041) 1.9 /SF 1168 SF 2219 BTU R -30 (U- .035) 1.6 /SF SF BTU (CONTINUED NEXT PAGE) TOTAL TII S PAGE = 28677 BTU Terhune Homes Inc. PO Box 1078 Auburn, Wa 98071 ��t� ;..� alb PERMIT CENTER -- \ 4 � �;.,�1 1)� Label �- r; 1�� 3435 Sq F .�;�,�" Gas Page 1 RECEIVED CITY OF TUKWILA JUN 2 5 1992 RGLG- SERIES Models with Input Rates from 50,000 to 150,000 BTU /HR (U.S. & Canadian Models) a Er IiC.ENCV wAliNr, crr'•rt, ama FORM NO. G11 -443 REV. 1 Supersedes Form No. 611.443 Rev. 0 MROF QUALITY '".. CRiTERIONTM 78 % -80% A.F.U.E t DOWNFLOW/ HORIZONTAL GAS FURNACES The Rheem '' Criterion'" line of downflow /horizontal" • • gas furnaces is designed for installation in closets, alcoves, util- ity rooms, or attics. The design is certified by the American Gas Association. Canadian models are certified by the Canadian Gas Association. Features • Patented Turbule0 heat exchanger, constructed of both stainless and aluminized steel for the maximum in corro- sion resistance. • Low profile "34 inch" design is lighter and easier to han- dle, and leaves room for optional equipment. • Both standing pilot (counterflow only) and hot surface ignition models available. ■ Left or right side gas and electric inlet connections with quick, simple change. • Hot surface ignition models feature an integrated board with humidifier and electronic air cleaner hookups. An accessory kit is available for standing pilot models. • Insulated blower compartment, a slow -open gas valve and a specially designed draft Inducer motor make it one of the quietest furnaces on the market today. • Downflow /Horizontal series allows this furnace to be installed in either downflow or horizontal configurations. "' • Hot surface ignition models may be laid on either side for horizontal installations. (No field converting required.) • Integrated solid state control board. ■ Pre -paint galvanized steel cabinet. • Molded permanent filter. • Grab -holes In doors to aid In easy door removal and replacement. A variety of cooling coils and plenums designed to use with Rheem Criterion gas furnaces are available as optional accessories for air conditioning models. tA.F.U,E. (Annual Fuel Utilization Elliciency) calculated in accordance with Depart. ment of Energy teal procedures. "'Horizontal applications require hot surface ignition models. MODEL NUMBERS RGLG•050AUEA ROLG•05EAUEA RGLG•075AUEA RGLG- 07EAUEA RGLG•075AMOA RGLO•07EAMOA RGLO.100AUEA RGLG•10EAUEA RGLO•100BRJA RGLG•10EBRJA RGLG•125ARJA RGL012EARJA RGLG•150ARJA RGLG•15EARJA INPUT•BTU /HR® 50,000 75,000 75,000 100,000 100,000 125,000 150,000 HEATING CAPACITY BTU /HR 41,000 59,500 60,500 80,000 81,000 99,000 119,500 HIGH ALTITUDE INPUT 45,000 67,500 67,500 90,000 90,000 112,500 135,000 HIGH ALTITUDE OUTPUT CAPACITY 36,500 53,500 54,000 72,000 72,500 89,000 107,500 HEAT EXT. STATIC PRESSURE .10 .12 .12 .15 .15 .20 .20 BLOWER (0xW) 11 x 6 11 x 6 11 x 7 11x6 11x10 11x10 11x10 MOTOR H.P./SPEEDS/TYPE ' /2.4•PSC 1 /2.3•PSC 3 /4•4•PSC ' /2.3•PSC 3 /4.4•1 3 SC 3 /4.4•PSC 3 /4.4•PSC MOTOR FULL LOAD AMPS 6.8 6.8 9.5 6.8 9,5 9.5 9.5 HEATING SPEED LOW LOW LOW LOW LOW LOW LOW COOLING SPEED HIGH HIGH HIGH HIGH HIGH HIGH HIGH COOLING CFM ® .5" E.S.P. (NOMINAL) 1200 1200 1600 1200 2000 2000 2000 MAX. EXT. STATIC PRESSURE (IN.) .50 .50 .50 .50 .50 .50 .50 TEMPERATURE RISE RANGE °F 25.55 40.70 25.55 55.85 40.70 45.75 50.80 STANDARD FILTER (1) 14 x 20 (2) 12 x 20 (2) 12 x 20 (2) 12 x 20 (2) 14 x 20 (2) 14 x 20 (2) 14 x 20 APPROX. SHIPPING WEIGHT (LBS.) 85 105 105 115 120 140 150 AFUE- STANDING PILOT MODELS 0 79.3% 78.6% 78,9% 78% 78% 78.1% 78,5% AFUE- H.S,I. MODELS O 82.2% 80.5% 80.8% 80% 80% 80% 80% • MODEL NUMBERS ROLG•050AUER RGLG- 05MAUER RGLG•05EAUER RGLG- 05NAUER RGLG•075AUER RGLG- 07MAUER RGLG•07EAUER RGLG- 07NAUER RGLG•075AMGR RGLG•07MAMGR ROLG•07EAMOR RGLG•07NAMGR RGLG•100AUER RGLO.10MAUER RGLG•10EAUER ROLO.10NAUER RGLG•100BRJR RGLG•10MBRJR RGLG•10EBRJR RGLG•10NBRJR RGLG•125ARJR RGLG•12MARJR RGLO.12EARJR RGLG•12NARJR RGLG•150ARJR RGLO•I5MARJR RGLG•15EARJR RGLG•15NARJR INPUT-BTU/HR 0 50,000 75,000 75,000 100,000 100,000 125,000 150,000 HEATING CAPACITY BTU /HR 41,000 59,500 60,500 80,000 81,000 99,000 119,500 HEAT EXT. STATIC PRESSURE .10 .12 .12 .15 .15 .20 .20 BLOWER (DxW) 11 x 6 11 x 6 11 x 7 11 x 6 11x10 11x10 11x10 MOTOR H.P. /SPEEDS /TYPE 1 /2.4•PSC 1 /2.3•PSC 3 /4.4 -PSC 1 /2.3•PSC 3 /4.4•PSC 3 /4.4•PSC 3 /4.4•PSC MOTOR FULL LOAD AMPS 6.8 6.8 9.5 6.8 9.5 9.5 9.5 HEATING SPEED LOW LOW LOW LOW LOW LOW LOW COOLING SPEED HIGH HIGH HIGH HIGH HIGH HIGH HIGH COOLING CFM @ .5" E.S.P. (NOMINAL) 1200 1200 1600 1200 2000 2000 2000 MAX. EXT. STATIC PRESSURE (IN.) .50 .50 .50 .50 .50 .50 .50 TEMPERATURE RISE RANGE °F 25.55 40.70 25.55 55.85 40.70 45.75 50.80 STANDARD FILTER (1) 14 x 20 (2) 12 x 20 (2) 12 x 20 (2) 12 x 20 (2) 14 x 20 (2) 14 x 20 (2) 14 x 20 APPROX. SHIPPING WEIGHT (LBS.) 85 105 105 115 120 140 150 AFUE- STANDING PILOT MODELS ® 79.3% 78.6% 78.9% 78% 78% 78.1% 78.5% AFUE- H.S.I. MODELS 0 82.2% 80.5% 80.8% 80% 80% 80% 80% BEFORE PURCHASING THIS APPLIAN( READ IMPORTANT ENERGY COST AND. EFF 'NCY INFORMATION AVAILABLE FROM YOUR RETAILER. PHYSICAL DATA AND SPECIFICATIONS -- (DOWNFLOW /HORIZONTAL) U.S. MODELS NOTES: All models are 115V, 60HZ, 10. Gas connection size for all models Is 1 /2" N.P.T. O In accordance with D.O.E. test procedures. C® See Conversion Kit Index Form No. 92.21519.30 for high altitude derate. PHYSICAL DATA AND SPECIFICATIONS - (DOWNFLOW /HORIZONTAL) CANADIAN MODELS : All models are 115V, 60HZ, 10. Gas connection size for all models is V2" N.P.T. CO In accordance with D.O.E. test procedures. 0 See Conversion Kit Index Form No. 92.21519.31 for high altitude derate. GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which falls in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty, Gas Heat Exchanger Warranty Twenty (20) Years Draft Inducer Warranty Five (5) Years Integrated Blower Control Board Warranty Five (5) Years (Standing Pilot and Hot Surface Control Boards) Any Other Part One (1) Year For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Factory for a Copy. NOTES. I. WHOLE MOUSE r VENTILATOR. Nog use) integrated spot and whole house system reverse plan unfinished basement floor plan terhune homes 3 Std' X 10° r'oc(od° 616ft .. . &XS nEvun+oiyrn -r X10 *k t 9)(5 1a17P (PritZ) tbEA 106.' TALL . I � r 1,11 - K R/A 5 x 121" % L1 R." (?. t= --A) : rat mYPI.43 ZIP stio 2 j 4° E i C4u- I2ax'I`= GARPar 1_ II.IEIJ 5D BI - Ltr r I 5 JP "V 5 AP 11' -o" -r- NOM: ti. WAI R Gt..c)Sitt 4d0tA6 MiTM1:*fr MtM tSp" wlPtr v -irrtt ?.s.o" t.�.EaR SPINCA era ri bwr a. iHSULt,..7g *u u.g .4.ste:Kitva Psw.^rtt4. z3, ALL caE.A.35 To FAT. 4.1 LtkY1917 c.mak e 4. Vt.OW P,S TO Ulla `° I1owErd 10 R.Ecc °ta hilegt4T TW .1 , TI4ER.M.0 LOOT \LN 1512" �! I IlL0n 'tp. I5L►Il4PIl To courov,1& Tc7. r cgUit"s�t�r4.1Ti oz. 1980 198o ic.INti oukrtt? 'j. t°itteTh'Iocv.4 .nt1P3P SUE'S � •41.1 gyp) 17 9,T &.-rest 'SFiPat. 13:, 1 F //A'T' - 'S(X.H t7C;Tte(:TMz, •ii,o.LL R'E c»t4w e... L, "ro A. :aLMI tt•.rr:_ O '. /IC,l:. ray, OTH Piz t7E7 arG.TUi.• To PI? Ovm ray, AN t t� " — At..7Dl t$I...1r IN Tt3 L..1~i; pf J tt.I EA. . ^ `If IIIIIIIIIIIIIIIIIIIIIJIIIIIIIIIlIIIIl {1IIII'. IIf!ilfi{tf'Ir " 16 THSINCN 1 9 11 11 1111111 111 r. I . ►._dt_ zr= {111111 l {If 1111 1{If111f1L ., 7 l` T-Cn 1 d-4° .._. • 011 RevaR6e PLAKi r ,r G, °3 C.D' -40" 1 r / ; it , . v 0 1f� Ream) ) CITY OF TUKWILA JUN 2 5 PERMIT CENTER II 1111 • IIIIIultIIll I