HomeMy WebLinkAboutPermit M92-0234 - BERNARD IMPORTSM92-0234 BERNARD IMPORTS
11020 EAST MARGINAL WAY SOUTH HVAC
IMPORTS
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
Permit No: M92 -0234
Type: B -MECH
Category: NRES
Address: 11020 EAST MARGINAL WY S
Location:
Parcel #: 032304 -9167
Contractor License No:
Signature:
Print Name:
TENANT BERNARD IMPORTS Phone: 206 248 -2242
11020 EAST MARGINAL WY S, TUKWILA, WA 98168
OWNER MC CONKEY DEVELOPMENT Phone: (206)889 -1180
3006 NORTHUP WAY, BELLEVUE WA 98004
CONTACT BERNARD ERIC Phone: 206 248 -2242
14100 INTERURBAN AVE SOUTH, TUKWILA, WA 98168
******************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Permit Description:
MECHANICAL PERMIT
(206) 431 -3670
Status: ISSUED
Issued: 11/25/1992
Expires: 05/24/1993
INSTALL 3 "INFRARED GAS HEATERS.
UMC Edition: 1991 Valuations 2,800.00
Total Permit. Fee 52.50
****************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Date
Permit Center Authorized Signature
I hereby,,.certify that I have readrand examined this permit and know the
same to be true -.and correct.. All provisions of law and ordinances
governing be:
complied work will becomp.lied with ", whether specified herein or not.
The granting o this permit does not presume -to give authority to vi
or cancel: the provisions of any other`.state :or local laws regulating;
constructionor .the performance of work. ..I am'authorized to sign for and
obtain this:, bui l.ding per
This permit shall become null and void if the work is not.. commenced within
180 days from the :,date of issuance,.. or....ifthe work is suspended or
abandoned for a perlbdof 180 days' ;from 'the`:...last inspe'ct`ion.
PERMIT NO.
CONTACTED
1 ar
DATE READY
DATE NOTIFIED
< <- a Er b,
BY:
(inft.)
J)
PERMIT EXPIRES
2nd NOTIFICATION
BY:
(init.)
AMOUNT OWING
3RD NOTIFICATION
BY:
(Inft.)
MECHANICAL PERMIT
APPLICATION TRACKING
PLAN CHECK
NUMBER
mWQ- 0D3L1
REVIEW COMPLETED
PROJECT NAME
SITE ADDRESS
1 r1Gq [ pct
SUITE NO.
Loan,___ _ IY10■ nai try 5
INSTRUCTIONS TO STAFF
• Contacts with applicants or requests for information should be summarized in writing by staff so that
any time the status of the project may be ascertained.
• Plan corrections shall be completed and approved prior to sending on to the next department.
• Any conditions or requirements for the permit shall be noted on the plans or summarized concisely
in the form of a formal letter or memo, which will be attached to the permit.
• Please fill out your section of the tracking chart completely. Where information requested is not
applicable, so note by using "N /A ".
DEPARTMENTAL REVIEW
"X" In box Indicates which departments need to review the project.
I E PAf 'TM
ENT
BUILDING - s In, �caZ CONSULTANT: Date Sent - Date Approved -
initial review ROUTED
O FIRE
O PLANNING
O OTHER
gBUILDING -
final rnviaw
INIT:
ZONING:
IBAR/LAND USE CONDITIONS? ( jYes [] No
INIT:
INIT:
FIRE DEPT. LETTER DATED:
UMC EDITION (year):
UIREKIl. N
FIRE PROTECTION: Sprinklers
Detectors
INSPECTOR:
N/A
SCREENING REQUIRED? fYes (l No
REFERENCE FILE NOS.:
l99
SITE ADDRESS SUITE #
11020 East Marginal Way South
VALUE OF CONSTRUCTION - $
2800.00
PROJECT NAME/TENANT
Bernard Imports
TYPE OF WORK: >a New /Addition 0 Modifications 0 Repair 0 Other:
DESCRIBE WORK TO BE DONE: install. 3 infrared gas heaters (existing gas service)
,. ;;. TYPE..: ..:....:.: ..,.::. ... . :
' ::<::,: ::;: : : : : : .. ... :. ::» : ::. :i ? : : ::: :: NUMBER:OF UNITS : ::
: : :::: ; :.: : ...:.......:.. . : ... RATtNG/SiZE >.:: :::: .
Vantage II Series low intensity ra iant eat 2' two 100,0 BTU
1 (one) 80,000 BTU
WA. ST. CONTRACTOR'S LICENSE # NA
EXP. DATE NA
BUILDING USE (office, warehouse, etc.)
B - 1 Auto service, parts and sales
NATURE OF BUSINESS:
same as current
WILL THERE BE A CHANGE IN USE? No 0 Yes IF YES, EXPLAIN:
WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE
BUILDING? 0 No Yes IF YES, EXPLAIN: 5 gals gas, antifreeze (same as current)
PROPERTY OWNER McConkey Development Co
PHONE 889 1180
ADDRESS 4040 - 168th Ave NE Redmond
ZIP 98052
CONTRACTOR work to be done by tenant, Bernard Imports
PHONE 248 2242
ADDRESS 14100 Interurban Ave So Tukwila
ZIP 98168
WA. ST. CONTRACTOR'S LICENSE # NA
EXP. DATE NA
CITY OF TUKWILA
Department of Community Development - Building
6300 Southcenter Boulevard, Tukwila WA 98188
(206) 431 -3670
PLAN CHECK
NUMBER
Ynci
APPLICATION MUST BE FILLED OUT COMPLETELY
BUILDING OWNER
OR
AUTHORIZED
AGENT
CONTACT PERSON
ADDRESS
14100 Interurban Ave So
Eric Bernard
MECHAF CAL PERMIT
APPLICATION
Division
Mechanical F
DESCRIPTION
BASIC PERMIT :FEE '
UN
PLAN: CHECK
OTHER
I) EXAM INEDT IS:.
D >TO''APPL:Y
Worksheet must also be filled out
and 4itached to this application.
t' FEES (for staff use only)
TOTAL': : -
AMOUNT"' ' . RCPT.:t
15.00'
DATE
PHONE 248 2242
PHONE 248 2242
DATE''
October 30, 1992
CITY /ZIPTukwila 98168
APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill
out the application completely and follow the plan submittal checklist on the reverse side of this form. A completed
"Mechanical Permit Fee Worksheet" must accompany this permit application. Handouts are available at the Building
counter which provide more detailed information on application and plan submittal requirements. Application and
plans must be complete in order to be accepted for plan review.
BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or
contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent
to submit this permit application and obtain the permit will be required as part of this submittal.
VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the
applicant. This figure is used for budget reporting purposes only and not to calculate your fees.
EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of
application shall expire by limitation. The Building Official may extend the time for action by the applicant for a
period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform
Mechanical Code (current edition). No application shall be extended more than once.
If you have any questions about our process or plan submittal requirements,
please contact the Department of Community Development at 431 -3670.
DATE APPLICATION ACCEPTED I DATE APPLICATION EXPIRES
SUICMITTAL CHECKL
MECHANICAL
n Completed mechanical permit application (one for each structure or tenant)
n Two (2) sets of mechanical plans, which include:
• Floor plan
• System layout
• Elevations (for roof mounted equipment)
• Heat Loss Calculations
n Structural calculations stamped by a Washington State licensed engineer may be
required if structural work is to be done (2 sets)
Note: Hood and duct systems require a building permit for the duct shaft.
DESCRIPTION
UNIT COST
NO OF
UNITS
X
TOTAL
COST
BASIC FEE
$15.00
$4.50
SUPPLEMENT PERMIT FEE
1
Installation or relocation of each forced -air gravity -type furnace or
burner, including ducts and vents attached to such appliance, up to and
including 100,000 Btu /h.
$9.00
X
2
Installation or relocation of each forced -air or gravity -type furnace or
burner, including ducts and vents attached to such appliance over
100,000 Btu /h.
$11.00
x
3
Installation or relocation of each floor furnace, including vent.
$9.00
x
4
Installation or relocation of each suspended heater, recessed wall heater
or floor- mounted unit heater.
$9.00
X
5
Installation, relocation or replacement of each appliance vent installed and
not included in an appliance permit.
$4,50
x
6
Repair of, alteration of, or addition to each heating appliance,
refrigeration unit, cooling unit, absorption unit, or each heating, cooling,
absorption, or evaporative cooling system, including installation of
controls regulated by this code.
$9.00
X
7
Installation or relocation of each boiler or compressor to and including
three horsepower, or each absorption system to and including 100,000
Btu /h.
$9,00
X
8
Installation or relocation of each boiler or compressor over three
horsepower to and including 15 horsepower, or each absorption system
over 100,000 Btu /h and including 500,000 Btu /h.
$16.50
X
9
Installation or relocation of each boiler or compressor over 15
horsepower to and including 30 horsepower, or each absorption system
over 500,000 Btu /h to and including 1,750,000 Btu /h.
$22.50
X
10
Installation or relocation of each boiler or compressor over 30
horsepower to and including 50 horsepower, or for each absorption
system over 1,000,000 Btu /h to and including 1,750,000 Btu /h.
$33.50
x
11
Installation or relocation of each boiler or refrigeration compressor over
50 horsepower, or each absorption system over 1,750,000 Btu /h.
$56.00
X
12
Each air- handling unit to and including 10,000 cubic feet per minute,
Including ducts attached thereto. (NOTE: This fee shall not apply to an
air - handling unit which is a portion of a factory- assembled appliance,
cooling unit, evaporative cooler or absorption unit for which a permit is
required elsewhere in this code.)
$6.50
X
13
Each air - handling unit over 10,000 cfm.
$11.00
X
14
Each evaporative cooler other than a portable type.
$6.50
X
15
Each ventilation fan connected to a single duct.
$4.50
X
16
Each ventilation system which is not a portion of any heating or
air - conditioning system authorized by a permit.
$6.50
X
17
installation of each hood which is served by mechanical exhaust, including
the ducts for such hood.
$6.50
X
18
Installation or relocation of each commercial or industrial -type incinerator.
$11.00
X
19
Installation or relocation of each commercial or Industrial -type incinerator.
$45.00
x
20
i
Each appliance or piece of equipment regulated by the code but not
classed in other appliance categories, or for which no other fee is listed in
this code.
$6.50
X
SUBTOTAL
PLAN CHECK FEE (25% of
•
CITY OF TUKWILA
Department of Community Development - Building Division
6300 Southcenter Boulevard, Tukwila WA 98188
(206) 431 -3670
THIS WORKSHEET MUST ACCOMPANY
YOUR MECHANICAL PERMIT APPLICATION.
MECHAN' )AL PERMIT
FEE WORKSHEET
INSTRUCTIONS - Complete the worksheet,
indicating the ; number of units being
installed in each category At time of •
submittal, staff will calculate the. fees
i•
**kisr**#***********Itir***************h*****'******k**.k***1!****#**
CITY OF TUKWILA WA TRANSMIT
***********************4c*******************A4*******.?(4!**.?r*****'
TRANSMIT Number: 92001359 Amottrit . 52.50 11/25/92 i4:3
Permit No. M92-0234 Type: B-MECH MECHANICAL PERMIT
Parcel No 032304-9167
Site Address: 11020 EAST MARGINAL WY S
Payment Method: CHECK Notation: BERNARD IMPORTS Ini
Account Code Description Paid
10.50
42.00
52.5Q
000/345.830
000/322.400
PLAN CHECK NONRES
MECHANICAL - NONRES
Tot41 (This Payment):
Tot;a1 Fees: 52.50
,• •
• Total' All Payments: . 52.50
Dal ance: . 00
GENERA 162.00
GENERA 4.50
GENERA 10.50
GENERA 42M00
TOTAL 219.00
CHECK 219.00
CHANGE 0.00
•5560A000 16:17
Address:
Tenant:
Type:
Parcel #:
11020 EAST MARGIN4L WY S
BERNARD IMPORTS
B7MECH
032304-9167
I
lk,! CITY OF TUKWILA
****-0i**********************************************************.i***********
Permit Conditions:
1. No changes will be made to the plans unless approved by the
Tukwtla Building Division.
2. _Plumbing permit shall be obtalne4...thrpugh the Seattle-King .•
County Department of P y . b 1 1 ; c : " , 7 1 - 1 0 3 1 X . f i ; i : S " P i lu. m bing w i l l be
inspected by that ageh frig a
(296-4722) .
. .
3. El ectri ca 1 per,netsha 1 1, be, ng ton
State Division lea d all e e'60.ca 1
work will 0e;`) that agency ,.?(248...z6657),;i's- •
4. All permits, Inspection records, and iappr,ove'8,.,, st41;,1.\ be
ma i ntained available at the Job s1te prior to the start of
any construction These documents are to be ''maintained
•available' until ''final ins,p'6 on approval is granted 5. Al 1 cOn.,v, trtic i on to be . 04- 1 conf.61"mance with approved
•plans krequirements ;;O the' Uniform Building Code (1491t
Ed i ,asa'merfded by the Wa State Building CO'4.e1
Uniform k)e ch13 n tca 1 Code — 14,9,94* d t 100 , and Washington State
Energy Code '(1991 Secorids )
•
6 of Permit The Issuance .6f a permit or approval of
plans, . y specifications - "apd coniputations ,.(shall not be cony con-
stnue to be a P e rmft"''f o an approval of, any v i o l a t i o n
of 0 of s i on s code or of any other
ord1nnce of the iurisdi ) ctipn.. t'..p um i ng to give
• , authority or violate or q th e rpv,.ti: ons of this code'
.. 'sha 1 'bw a Vi
o
Permit No:
Status:
Applied:
Issued:
M92-0234
ISSUED
10/30/1992
11/25/1992
•il.0 ,
,,,..W.....,-:'
i i
0.
- . 4S
0
4 . '
•
Project:
h 1 l'Pti
Type o nspect n:
`��
Address: Za R
/ ��
/
^
.. V
D ate Called: f Z= 2_8_4,
Special Instructions:
Date Wanted: /
! �"�"Jc am.
j
Requester:
Phone No.:
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
X Approved per applicable codes.
( INSPECTION RECORD
Retain a copy with permit
❑ Corrections required prior to approval.
COMMENTS: '
4_ 7 /
Date : � ' l
❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at
6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Project:
(7 Pm(.i -r.P�
.0
Type of Inspectkn:
/iGe 4 .
Address:
NO AO �-�
/ 1e s 5
Date Called:
Special Instructions:
Date Wanted:
/2y - 2-03—
am. p.m.
Requester:
Phone No.:
❑ Apjxoved per applicable codes.
( Inspector:
INSPECTION RECORD C
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Corrections required prior to approval.
COMMENTS: '
/3 ,l ( /.�,� -,c.�. fj ro.-er,Gd ci7Z-
/3- Vr�„ �" ? 001-1-4, 01-T '9 4 _ V
" leafr-Ge41z-iP
Z� zipvi n-p e6L
2 j c�' •� `►mil rL 5 !
4 _,i-1 , 7,7-1
Date:
❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at
6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
(206) 431 -3670
11
SERVICE BAY 1
UNT STAT OUTSIDE— I
CUSTOMER WAITING AREA
�--
TO SERVICE PANEL, 1115V 20A
—�-- G
I CTH2 — t 00 ' W
SIDE' REFLECTOR
SERVICE BAY 2 SERVICE BAT 3
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
—1 t
SERVICE BAY 6
MOUNT STAT OUTSIDE .
PARTS STORAGE ROOM :
•
15V 20A
• CTH2 -80 G
;2541:" VTR
OFFSET AWAY FROM
STRUCTURAL MEMBER
J—
E ICAO, SF -ajIGE
g4s - ptp(Ng.
HANG FROM INSIDE FACE OF
ROOF STRUCTURAL MEMBER
162'0"
SERVICE BAY 4 SERVICE BAY 5
(WASH)
CT1-42 -100• W /SIDE REFLECTOR
7a`9
t understand
Subject to er
plans sloes n
adopted c
copy of appr
By
Date,
Permit
•
•
•
•
•
•
•
•
1
SERVICE BAY 6
MOUNT STAT OUTSIDE :
PARTS STORAGE ROOM :
-�-TO SERVICE PANEL, 15V 20A
;24" VTR
OFFSET AWAY FROM
STRUCTURAL MEMBER
BAY 2 SERVICE BAY 3
20A
•
•
•
•
•
•
•
•
•
•
•
a 0 n xI
CTH2 -80 G
1 - A 11
HANG FROM INSIDE FACE OF
ROOF STRUCTURAL MEMBER
•
•
•
•
•
•
•
•
J-
162'0'
. FZ C 2ICAL
(-
BAs"fitp Nct.
SERVICE BAY 4 SERVICE BAY 5
I _ (WASH)
G
• •C1112• =1•0• W /SIDE REFLECTOR
11 •
I understand that the Plan Check approvals are
^!ubject to errors and missions and approval of
plans does not authorize the violation of any
adopted code or ordi ante. Receipt of contractor's
copy of approved plops acknowied
! i
By i tAIL"
Date I L - ' ' q
Permit No I fl.l.!-ka _ 00 L i
CITY OF TUKWILA
APPROVED
Nij x, 11992
fl! !' D MG ISION
IBIDED
COYOF uauIA
OCT 3 0 1992
Four =Mt
49 6
Cost-Saving,
Low-Intensity Infrared
Unitary Heaters
.gnorgyE *lent Comfort.
Roberts-Gordon, Inc.
RECEIVED
CITY OF TUKWILA
NOV 1 3 1992
PERMIT CEN1ER
VANTAGE II Unitary Heaters
Lower Fuel Costs
and Raise Comfort Levels.
Demonstrated Savings
Modern gas combustion technology combined with the
principles of infrared energy enable VANTAGE II heaters to
reduce fuel costs substantially while improving comfort con-
ditions. Users report heating bills cut by up to 50'%, and more!
Low Cost... Easy to Install
and Maintain
The VANTAGE II models are low -cost, field - assembled
infrared heaters that are easy to install and require only
minimal maintenance. They are designed to provide years of
economical operation and trouble -free service.
• Automotive Facilities
• Warehouses
• Manufacturing Facilities
Clean, quiet, draft -free Vantage radiant
heat is ideal for this automotive ser-
vice facility. Unlike forced -air unit heat-
ers, Vantage does not spread dirt, grit
or dust.
Applications Include:
• Fire Stations
• Agricultural Buildings
• Recreational Facilities
•
Versatility
Vantage unitary heaters are available in
a variety of lengths, shapes and config-
urations to lit any floor plan. 'Iwo
straight -tube models are shown above
in a car dealership.
VAN'IAGE I I heaters can he installed separately or in com-
bination to tit any floor plan. Straight, L- and U -tube configu-
rations are available. Tube lengths are offered from 10
through 60 feet. Ideal for large areas as well as hard -to -heat
spaces!
Reliability and Expertise
Roberts- Gordon pioneered low - intensity infrared heating
systems in 1962 and manufactures the broadest line of low -
intensity heating equipment in North America. Backed by a
limited three -year warranty, each VANTAGE 11 unitary heater
is built to uphold the well- established Roberts - Gordon
standards of engineering excellence, efficiency and reliability.
\i ii'. + f •
„yttatt•.tittstttt lit. aataitit
.. 'w4ltk,t'alt
• Machine Shops
• Aircraft Hangars
• Vehicle Maintenance Buildings
Floors are kept warm by Vantage infra-
red energy and act as heat reservoirs to
provide rapid heat recovery after bay
doors are closed in this warehouse/
shipping area.
3
n
"The VANTAGE II heater
utilizes design concepts
and engineering principles
proven by more than 25
0 years of infrared heating
experience."
s
Features:
• Extensive use of corrosion- resistant
materials.
• Weight- saving construction to ease
installation.
• Forced draft design eliminates the
need for a heat- siphoning draft
hood.
• Quiet operation.
• 10 through 60 foot tube lengths.
• Three -year limited warranty on all
components.
• A.G.A. design certified.
Burner Box:
• 40,000; 60,000; 80,000; 100,000;
125,000 and 150,000 BTU /Hr.
models available.
• Natural gas and L.P. models
available.
• Moisture- resistant design.
• Stainless steel burner cup.
• Outside air adapter standard.
• Hot surface ignition.
• Three -try ignition module.
• Door interlock safety switch.
• All components easily accessed.
• Electrostatically applied paint.
• Durable spot welded construction.
• Mica flame observation window.
• Balanced air rotor.
• Stainless steel flex gas line and high
pressure gas cock included.
Architectural /Engineering Short Form Specifications
VANTAGE II CTH2 SERIES
Tube and Reflector:
• 4" diameter 16 gauge tubing.
• Quick assembly couplings.
• Deep -dish aluminum reflectors
maximize energy reflection, beam-
ing virtually all of the radiant heat
downward.
• Reflectors can be tilted 45 to
direct heat where needed.
• Entire U -tube heater also can be
tilted 45 °.
• End caps included.
• Nickel plated hangers.
• Chrome plated hardware.
• Flue connector included.
• 180° U- package (9" radius) option.
• 90° L- package option.
• Decorative grille option.
• Side reflector option.
Gas - fired, vented, infrared heaters shall be furnished and installed in accordance with governing codes and as shown per
building drawing(s) as described below.
Heaters shall be VANTAGE II, model number CTH2- BTU /Hr. as manufactured
by Roberts - Gordon, Inc., Buffalo, New York.
Heaters shall be equipped with a direct sense silicon - carbide hot surface ignition control system with 100% shut-off ignition
device. Power supplied to each heater shall be 120V, 60Hz, 10. Heater to be equipped with totally enclosed motor with
thermal overload motor protection, balanced air rotor, combustion air proving safety pressure switch, stainless steel
burnerhead, combustion chamber equipped with sight glass for visual inspection of igniter element and burner flame. Air
intake collar standard. Radiant tube assembly to be 4" diameter, aluminized steel first 10 feet. Hot rolled steel remainder of
unit. (Or at customer option, all aluminized steel for entire tube length.) Reflector to be of aluminum material and designed
to direct all radiant output below horizontal centerline of radiant tube. Heaters shall be vented in accordance with
manufacturer's recommendations and ANSI Z -223.1 National Fuel Gas Code. Heaters shall be so designed to operate
without requiring heater modifications or adjustments on gas having a net heating value of
BTU per cubic foot and a specific gravity of
Heaters shall be Design Certified by the American Gas Association (A.G.A.). Supplier shall provide a manufacturer's written
warranty covering all components for a period of three (3) years.
„,,,,,,, f, l, - A ,
7 ''`',
?-09,091011109,4
rr irl
''' il
'*
i 0044ocio
.,1
12-41g.croia-404
.
4
,kTop '
i, . i ,,,,,,
.
.
,,
..„
,-. v
A."4-
Top .
, -1 5 , ,I ,
C111240
100
4 ,r,0,..i.p
''6''' '
'W
rqt.i4.',41,3')e•.■
VVI
opL,
CT112-111r0t.V
k,. 4
, .
g4+4
ORA
7„
- 54" 4 /38
4 .,
A ., .
.4 . ,2 '
4 " 68"
4"/48"
WOI:firi0 0
„,
4"
50"
22"
4"
60"
30"
4"
63"
33
4"
68
35"
4"
74"
41"
4"
77"
45"
'/ sr MI
4
4"
45"
4"/42"
4"
54"
4"/50"
4"
60"
4"/56"
6"
68"
4"/60"
6"
72"
4"/65"
8"
78"
4"/70"
' 4
(AiliWkOtiii '4
-
-
-
4"
60"
25"/30"
4"
66"
32"/33"
4"
73
34"/35"
4"
76"
38"/41"
4"
81"
42 /45"
(,,I;T ,r;;;'
: ; , ;01,117,0040 ? "1,,,? , :?
-
-
-
4"
54"
18"/50"
4"
60"
18 /56
6"
68"
18"/60"
6"
72"
18"/66"
r
78
18 /70
FLUE . '.,
aokNEcric*::
. GAS ,
: CONNECTION
ELECTRICAL .'
RATING,
:::TOBE:'- ,,,
' 'DIAMETER ,,
. : :,' IGNITION ,:" '.-
',.".., 'SYSTEM
.,, IlikG ,
4" (O.D.)
1/2" NPT
120VAC, 60Hz.
1.0 amp run
5.0 amp start
4"
Hot surface
(Three-try)
Nat. 4.6" W.C.
L.P. 11.0" W.C.
„ ,
1 0 6 EL -*-:'7
i-:: ---`"-;" '•
BTLI/Hil
- : f..- (Natural Gas '
'‘!.,,.----- iieLFii' ',..',-`,
,•• • ,-..:••
..,,,, Aott,t„ , .•,,
4.
95 lbs.
9
130 lbs.
130 lbs.
CTH2-100
CTH2-125
CTH2-150
100,000
125,000
150,000
165 lbs.
200 lbs.
235 lbs.
To' =I Jiiss'Aill5=14*-W.
-, D '
.... .....
." .:...:,,
iiIiii0:Gii,i.:;•:-":.':::::'
iii 0.y•1••••:
,.„.. ..,• . • • ,-•
.. SHIPPING
"`"::•:;;;;;,."MlE;07q.:';:::.;',...."
..:,.., • • .... ...... ....• .
CTH2-40
CTH2-60
CTH2-80
40,000
60,000
80,000
95 lbs.
9
130 lbs.
130 lbs.
...',...cii -- ":0
";;;Iic.iiiiii■il.,';',
:I.**.
:7411:31E111:2211C3
:ft*.
1:25
:•:
1E9=
To' =I Jiiss'Aill5=14*-W.
1t
. 401.:1110-10
- 54" 4 /38
4 "
60"
4 /42
4 " 68"
4"/48"
4" 72" 57 4 " 78" e/62"
d}4;2i-
( pofq-rs A rrAcieli CTH2 SIPES
® SPECIFICATIONS
• L
Top View
DIMENSIONS (Standard Models) STRAIGHT
CTH2.40 (11' 10")
CTH2-60 (21' 4")
CTH2-80 (21' 4")
CTH2-100 (31' 4")
CTH2-125 (41' 4")
CTH2-150 (51' 4")
U-TUBE
r31:.
CTH2•60 (13')
CTH2-80 (13')
CTH2-100 (18')
CTH2-125 (23')
CTH2-150 (28')
*See installation manual for complete information.
Roberts-Gordon, Inc.
Subsidiary of A.J. Industries, Inc.
P.O. Box 44 • Buffalo, NY 14240-0044
Phone: (716) 852-4400 • Fax: (716) 852-0854
CALL TOLL FREE: 1-800-828-7450
IN NEW YORK: 1-800-221-0955
CLEARANCES TO COMBUSTIBLES*
REFLECTOR
HORIZONTAL
REFLECTORS HORIZONTAL
32"
1
6" j
REFLECTORS TILTED
11%"
REFLECTOR
TILTED
11
11143''
ENERGY SAVING PRODUCTS, INC.
889 GARDEN OF EDEN RD.
SEDRO WOOLLEY, WA 98284
1200) 858-2700
24"
24"
HEATER
TILTED