Loading...
HomeMy WebLinkAboutPermit M92-0234 - BERNARD IMPORTSM92-0234 BERNARD IMPORTS 11020 EAST MARGINAL WAY SOUTH HVAC IMPORTS Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M92 -0234 Type: B -MECH Category: NRES Address: 11020 EAST MARGINAL WY S Location: Parcel #: 032304 -9167 Contractor License No: Signature: Print Name: TENANT BERNARD IMPORTS Phone: 206 248 -2242 11020 EAST MARGINAL WY S, TUKWILA, WA 98168 OWNER MC CONKEY DEVELOPMENT Phone: (206)889 -1180 3006 NORTHUP WAY, BELLEVUE WA 98004 CONTACT BERNARD ERIC Phone: 206 248 -2242 14100 INTERURBAN AVE SOUTH, TUKWILA, WA 98168 ******************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: MECHANICAL PERMIT (206) 431 -3670 Status: ISSUED Issued: 11/25/1992 Expires: 05/24/1993 INSTALL 3 "INFRARED GAS HEATERS. UMC Edition: 1991 Valuations 2,800.00 Total Permit. Fee 52.50 ****************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Date Permit Center Authorized Signature I hereby,,.certify that I have readrand examined this permit and know the same to be true -.and correct.. All provisions of law and ordinances governing be: complied work will becomp.lied with ", whether specified herein or not. The granting o this permit does not presume -to give authority to vi or cancel: the provisions of any other`.state :or local laws regulating; constructionor .the performance of work. ..I am'authorized to sign for and obtain this:, bui l.ding per This permit shall become null and void if the work is not.. commenced within 180 days from the :,date of issuance,.. or....ifthe work is suspended or abandoned for a perlbdof 180 days' ;from 'the`:...last inspe'ct`ion. PERMIT NO. CONTACTED 1 ar DATE READY DATE NOTIFIED < <- a Er b, BY: (inft.) J) PERMIT EXPIRES 2nd NOTIFICATION BY: (init.) AMOUNT OWING 3RD NOTIFICATION BY: (Inft.) MECHANICAL PERMIT APPLICATION TRACKING PLAN CHECK NUMBER mWQ- 0D3L1 REVIEW COMPLETED PROJECT NAME SITE ADDRESS 1 r1Gq [ pct SUITE NO. Loan,___ _ IY10■ nai try 5 INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". DEPARTMENTAL REVIEW "X" In box Indicates which departments need to review the project. I E PAf 'TM ENT BUILDING - s In, �caZ CONSULTANT: Date Sent - Date Approved - initial review ROUTED O FIRE O PLANNING O OTHER gBUILDING - final rnviaw INIT: ZONING: IBAR/LAND USE CONDITIONS? ( jYes [] No INIT: INIT: FIRE DEPT. LETTER DATED: UMC EDITION (year): UIREKIl. N FIRE PROTECTION: Sprinklers Detectors INSPECTOR: N/A SCREENING REQUIRED? fYes (l No REFERENCE FILE NOS.: l99 SITE ADDRESS SUITE # 11020 East Marginal Way South VALUE OF CONSTRUCTION - $ 2800.00 PROJECT NAME/TENANT Bernard Imports TYPE OF WORK: >a New /Addition 0 Modifications 0 Repair 0 Other: DESCRIBE WORK TO BE DONE: install. 3 infrared gas heaters (existing gas service) ,. ;;. TYPE..: ..:....:.: ..,.::. ... . : ' ::<::,: ::;: : : : : : .. ... :. ::» : ::. :i ? : : ::: :: NUMBER:OF UNITS : :: : : :::: ; :.: : ...:.......:.. . : ... RATtNG/SiZE >.:: :::: . Vantage II Series low intensity ra iant eat 2' two 100,0 BTU 1 (one) 80,000 BTU WA. ST. CONTRACTOR'S LICENSE # NA EXP. DATE NA BUILDING USE (office, warehouse, etc.) B - 1 Auto service, parts and sales NATURE OF BUSINESS: same as current WILL THERE BE A CHANGE IN USE? No 0 Yes IF YES, EXPLAIN: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? 0 No Yes IF YES, EXPLAIN: 5 gals gas, antifreeze (same as current) PROPERTY OWNER McConkey Development Co PHONE 889 1180 ADDRESS 4040 - 168th Ave NE Redmond ZIP 98052 CONTRACTOR work to be done by tenant, Bernard Imports PHONE 248 2242 ADDRESS 14100 Interurban Ave So Tukwila ZIP 98168 WA. ST. CONTRACTOR'S LICENSE # NA EXP. DATE NA CITY OF TUKWILA Department of Community Development - Building 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK NUMBER Ynci APPLICATION MUST BE FILLED OUT COMPLETELY BUILDING OWNER OR AUTHORIZED AGENT CONTACT PERSON ADDRESS 14100 Interurban Ave So Eric Bernard MECHAF CAL PERMIT APPLICATION Division Mechanical F DESCRIPTION BASIC PERMIT :FEE ' UN PLAN: CHECK OTHER I) EXAM INEDT IS:. D >TO''APPL:Y Worksheet must also be filled out and 4itached to this application. t' FEES (for staff use only) TOTAL': : - AMOUNT"' ' . RCPT.:t 15.00' DATE PHONE 248 2242 PHONE 248 2242 DATE'' October 30, 1992 CITY /ZIPTukwila 98168 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. A completed "Mechanical Permit Fee Worksheet" must accompany this permit application. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 431 -3670. DATE APPLICATION ACCEPTED I DATE APPLICATION EXPIRES SUICMITTAL CHECKL MECHANICAL n Completed mechanical permit application (one for each structure or tenant) n Two (2) sets of mechanical plans, which include: • Floor plan • System layout • Elevations (for roof mounted equipment) • Heat Loss Calculations n Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) Note: Hood and duct systems require a building permit for the duct shaft. DESCRIPTION UNIT COST NO OF UNITS X TOTAL COST BASIC FEE $15.00 $4.50 SUPPLEMENT PERMIT FEE 1 Installation or relocation of each forced -air gravity -type furnace or burner, including ducts and vents attached to such appliance, up to and including 100,000 Btu /h. $9.00 X 2 Installation or relocation of each forced -air or gravity -type furnace or burner, including ducts and vents attached to such appliance over 100,000 Btu /h. $11.00 x 3 Installation or relocation of each floor furnace, including vent. $9.00 x 4 Installation or relocation of each suspended heater, recessed wall heater or floor- mounted unit heater. $9.00 X 5 Installation, relocation or replacement of each appliance vent installed and not included in an appliance permit. $4,50 x 6 Repair of, alteration of, or addition to each heating appliance, refrigeration unit, cooling unit, absorption unit, or each heating, cooling, absorption, or evaporative cooling system, including installation of controls regulated by this code. $9.00 X 7 Installation or relocation of each boiler or compressor to and including three horsepower, or each absorption system to and including 100,000 Btu /h. $9,00 X 8 Installation or relocation of each boiler or compressor over three horsepower to and including 15 horsepower, or each absorption system over 100,000 Btu /h and including 500,000 Btu /h. $16.50 X 9 Installation or relocation of each boiler or compressor over 15 horsepower to and including 30 horsepower, or each absorption system over 500,000 Btu /h to and including 1,750,000 Btu /h. $22.50 X 10 Installation or relocation of each boiler or compressor over 30 horsepower to and including 50 horsepower, or for each absorption system over 1,000,000 Btu /h to and including 1,750,000 Btu /h. $33.50 x 11 Installation or relocation of each boiler or refrigeration compressor over 50 horsepower, or each absorption system over 1,750,000 Btu /h. $56.00 X 12 Each air- handling unit to and including 10,000 cubic feet per minute, Including ducts attached thereto. (NOTE: This fee shall not apply to an air - handling unit which is a portion of a factory- assembled appliance, cooling unit, evaporative cooler or absorption unit for which a permit is required elsewhere in this code.) $6.50 X 13 Each air - handling unit over 10,000 cfm. $11.00 X 14 Each evaporative cooler other than a portable type. $6.50 X 15 Each ventilation fan connected to a single duct. $4.50 X 16 Each ventilation system which is not a portion of any heating or air - conditioning system authorized by a permit. $6.50 X 17 installation of each hood which is served by mechanical exhaust, including the ducts for such hood. $6.50 X 18 Installation or relocation of each commercial or industrial -type incinerator. $11.00 X 19 Installation or relocation of each commercial or Industrial -type incinerator. $45.00 x 20 i Each appliance or piece of equipment regulated by the code but not classed in other appliance categories, or for which no other fee is listed in this code. $6.50 X SUBTOTAL PLAN CHECK FEE (25% of • CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 THIS WORKSHEET MUST ACCOMPANY YOUR MECHANICAL PERMIT APPLICATION. MECHAN' )AL PERMIT FEE WORKSHEET INSTRUCTIONS - Complete the worksheet, indicating the ; number of units being installed in each category At time of • submittal, staff will calculate the. fees i• **kisr**#***********Itir***************h*****'******k**.k***1!****#** CITY OF TUKWILA WA TRANSMIT ***********************4c*******************A4*******.?(4!**.?r*****' TRANSMIT Number: 92001359 Amottrit . 52.50 11/25/92 i4:3 Permit No. M92-0234 Type: B-MECH MECHANICAL PERMIT Parcel No 032304-9167 Site Address: 11020 EAST MARGINAL WY S Payment Method: CHECK Notation: BERNARD IMPORTS Ini Account Code Description Paid 10.50 42.00 52.5Q 000/345.830 000/322.400 PLAN CHECK NONRES MECHANICAL - NONRES Tot41 (This Payment): Tot;a1 Fees: 52.50 ,• • • Total' All Payments: . 52.50 Dal ance: . 00 GENERA 162.00 GENERA 4.50 GENERA 10.50 GENERA 42M00 TOTAL 219.00 CHECK 219.00 CHANGE 0.00 •5560A000 16:17 Address: Tenant: Type: Parcel #: 11020 EAST MARGIN4L WY S BERNARD IMPORTS B7MECH 032304-9167 I lk,! CITY OF TUKWILA ****-0i**********************************************************.i*********** Permit Conditions: 1. No changes will be made to the plans unless approved by the Tukwtla Building Division. 2. _Plumbing permit shall be obtalne4...thrpugh the Seattle-King .• County Department of P y . b 1 1 ; c : " , 7 1 - 1 0 3 1 X . f i ; i : S " P i lu. m bing w i l l be inspected by that ageh frig a (296-4722) . . . 3. El ectri ca 1 per,netsha 1 1, be, ng ton State Division lea d all e e'60.ca 1 work will 0e;`) that agency ,.?(248...z6657),;i's- • 4. All permits, Inspection records, and iappr,ove'8,.,, st41;,1.\ be ma i ntained available at the Job s1te prior to the start of any construction These documents are to be ''maintained •available' until ''final ins,p'6 on approval is granted 5. Al 1 cOn.,v, trtic i on to be . 04- 1 conf.61"mance with approved •plans krequirements ;;O the' Uniform Building Code (1491t Ed i ,asa'merfded by the Wa State Building CO'4.e1 Uniform k)e ch13 n tca 1 Code — 14,9,94* d t 100 , and Washington State Energy Code '(1991 Secorids ) • 6 of Permit The Issuance .6f a permit or approval of plans, . y specifications - "apd coniputations ,.(shall not be cony con- stnue to be a P e rmft"''f o an approval of, any v i o l a t i o n of 0 of s i on s code or of any other ord1nnce of the iurisdi ) ctipn.. t'..p um i ng to give • , authority or violate or q th e rpv,.ti: ons of this code' .. 'sha 1 'bw a Vi o Permit No: Status: Applied: Issued: M92-0234 ISSUED 10/30/1992 11/25/1992 •il.0 , ,,,..W.....,-:' i i 0. - . 4S 0 4 . ' • Project: h 1 l'Pti Type o nspect n: `�� Address: Za R / �� / ^ .. V D ate Called: f Z= 2_8_4, Special Instructions: Date Wanted: / ! �"�"Jc am. j Requester: Phone No.: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 X Approved per applicable codes. ( INSPECTION RECORD Retain a copy with permit ❑ Corrections required prior to approval. COMMENTS: ' 4_ 7 / Date : � ' l ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Project: (7 Pm(.i -r.P� .0 Type of Inspectkn: /iGe 4 . Address: NO AO �-� / 1e s 5 Date Called: Special Instructions: Date Wanted: /2y - 2-03— am. p.m. Requester: Phone No.: ❑ Apjxoved per applicable codes. ( Inspector: INSPECTION RECORD C Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Corrections required prior to approval. COMMENTS: ' /3 ,l ( /.�,� -,c.�. fj ro.-er,Gd ci7Z- /3- Vr�„ �" ? 001-1-4, 01-T '9 4 _ V " leafr-Ge41z-iP Z� zipvi n-p e6L 2 j c�' •� `►mil rL 5 ! 4 _,i-1 , 7,7-1 Date: ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (206) 431 -3670 11 SERVICE BAY 1 UNT STAT OUTSIDE— I CUSTOMER WAITING AREA �-- TO SERVICE PANEL, 1115V 20A —�-- G I CTH2 — t 00 ' W SIDE' REFLECTOR SERVICE BAY 2 SERVICE BAT 3 SEPARATE PERMIT AND APPROVAL REQUIRED —1 t SERVICE BAY 6 MOUNT STAT OUTSIDE . PARTS STORAGE ROOM : • 15V 20A • CTH2 -80 G ;2541:" VTR OFFSET AWAY FROM STRUCTURAL MEMBER J— E ICAO, SF -ajIGE g4s - ptp(Ng. HANG FROM INSIDE FACE OF ROOF STRUCTURAL MEMBER 162'0" SERVICE BAY 4 SERVICE BAY 5 (WASH) CT1-42 -100• W /SIDE REFLECTOR 7a`9 t understand Subject to er plans sloes n adopted c copy of appr By Date, Permit • • • • • • • • 1 SERVICE BAY 6 MOUNT STAT OUTSIDE : PARTS STORAGE ROOM : -�-TO SERVICE PANEL, 15V 20A ;24" VTR OFFSET AWAY FROM STRUCTURAL MEMBER BAY 2 SERVICE BAY 3 20A • • • • • • • • • • • a 0 n xI CTH2 -80 G 1 - A 11 HANG FROM INSIDE FACE OF ROOF STRUCTURAL MEMBER • • • • • • • • J- 162'0' . FZ C 2ICAL (- BAs"fitp Nct. SERVICE BAY 4 SERVICE BAY 5 I _ (WASH) G • •C1112• =1•0• W /SIDE REFLECTOR 11 • I understand that the Plan Check approvals are ^!ubject to errors and missions and approval of plans does not authorize the violation of any adopted code or ordi ante. Receipt of contractor's copy of approved plops acknowied ! i By i tAIL" Date I L - ' ' q Permit No I fl.l.!-ka _ 00 L i CITY OF TUKWILA APPROVED Nij x, 11992 fl! !' D MG ISION IBIDED COYOF uauIA OCT 3 0 1992 Four =Mt 49 6 Cost-Saving, Low-Intensity Infrared Unitary Heaters .gnorgyE *lent Comfort. Roberts-Gordon, Inc. RECEIVED CITY OF TUKWILA NOV 1 3 1992 PERMIT CEN1ER VANTAGE II Unitary Heaters Lower Fuel Costs and Raise Comfort Levels. Demonstrated Savings Modern gas combustion technology combined with the principles of infrared energy enable VANTAGE II heaters to reduce fuel costs substantially while improving comfort con- ditions. Users report heating bills cut by up to 50'%, and more! Low Cost... Easy to Install and Maintain The VANTAGE II models are low -cost, field - assembled infrared heaters that are easy to install and require only minimal maintenance. They are designed to provide years of economical operation and trouble -free service. • Automotive Facilities • Warehouses • Manufacturing Facilities Clean, quiet, draft -free Vantage radiant heat is ideal for this automotive ser- vice facility. Unlike forced -air unit heat- ers, Vantage does not spread dirt, grit or dust. Applications Include: • Fire Stations • Agricultural Buildings • Recreational Facilities • Versatility Vantage unitary heaters are available in a variety of lengths, shapes and config- urations to lit any floor plan. 'Iwo straight -tube models are shown above in a car dealership. VAN'IAGE I I heaters can he installed separately or in com- bination to tit any floor plan. Straight, L- and U -tube configu- rations are available. Tube lengths are offered from 10 through 60 feet. Ideal for large areas as well as hard -to -heat spaces! Reliability and Expertise Roberts- Gordon pioneered low - intensity infrared heating systems in 1962 and manufactures the broadest line of low - intensity heating equipment in North America. Backed by a limited three -year warranty, each VANTAGE 11 unitary heater is built to uphold the well- established Roberts - Gordon standards of engineering excellence, efficiency and reliability. \i ii'. + f • „yttatt•.tittstttt lit. aataitit .. 'w4ltk,t'alt • Machine Shops • Aircraft Hangars • Vehicle Maintenance Buildings Floors are kept warm by Vantage infra- red energy and act as heat reservoirs to provide rapid heat recovery after bay doors are closed in this warehouse/ shipping area. 3 n "The VANTAGE II heater utilizes design concepts and engineering principles proven by more than 25 0 years of infrared heating experience." s Features: • Extensive use of corrosion- resistant materials. • Weight- saving construction to ease installation. • Forced draft design eliminates the need for a heat- siphoning draft hood. • Quiet operation. • 10 through 60 foot tube lengths. • Three -year limited warranty on all components. • A.G.A. design certified. Burner Box: • 40,000; 60,000; 80,000; 100,000; 125,000 and 150,000 BTU /Hr. models available. • Natural gas and L.P. models available. • Moisture- resistant design. • Stainless steel burner cup. • Outside air adapter standard. • Hot surface ignition. • Three -try ignition module. • Door interlock safety switch. • All components easily accessed. • Electrostatically applied paint. • Durable spot welded construction. • Mica flame observation window. • Balanced air rotor. • Stainless steel flex gas line and high pressure gas cock included. Architectural /Engineering Short Form Specifications VANTAGE II CTH2 SERIES Tube and Reflector: • 4" diameter 16 gauge tubing. • Quick assembly couplings. • Deep -dish aluminum reflectors maximize energy reflection, beam- ing virtually all of the radiant heat downward. • Reflectors can be tilted 45 to direct heat where needed. • Entire U -tube heater also can be tilted 45 °. • End caps included. • Nickel plated hangers. • Chrome plated hardware. • Flue connector included. • 180° U- package (9" radius) option. • 90° L- package option. • Decorative grille option. • Side reflector option. Gas - fired, vented, infrared heaters shall be furnished and installed in accordance with governing codes and as shown per building drawing(s) as described below. Heaters shall be VANTAGE II, model number CTH2- BTU /Hr. as manufactured by Roberts - Gordon, Inc., Buffalo, New York. Heaters shall be equipped with a direct sense silicon - carbide hot surface ignition control system with 100% shut-off ignition device. Power supplied to each heater shall be 120V, 60Hz, 10. Heater to be equipped with totally enclosed motor with thermal overload motor protection, balanced air rotor, combustion air proving safety pressure switch, stainless steel burnerhead, combustion chamber equipped with sight glass for visual inspection of igniter element and burner flame. Air intake collar standard. Radiant tube assembly to be 4" diameter, aluminized steel first 10 feet. Hot rolled steel remainder of unit. (Or at customer option, all aluminized steel for entire tube length.) Reflector to be of aluminum material and designed to direct all radiant output below horizontal centerline of radiant tube. Heaters shall be vented in accordance with manufacturer's recommendations and ANSI Z -223.1 National Fuel Gas Code. Heaters shall be so designed to operate without requiring heater modifications or adjustments on gas having a net heating value of BTU per cubic foot and a specific gravity of Heaters shall be Design Certified by the American Gas Association (A.G.A.). Supplier shall provide a manufacturer's written warranty covering all components for a period of three (3) years. „,,,,,,, f, l, - A , 7 ''`', ?-09,091011109,4 rr irl ''' il '* i 0044ocio .,1 12-41g.croia-404 . 4 ,kTop ' i, . i ,,,,,, . . ,, ..„ ,-. v A."4- Top . , -1 5 , ,I , C111240 100 4 ,r,0,..i.p ''6''' ' 'W rqt.i4.',41,3')e•.■ VVI opL, CT112-111r0t.V k,. 4 , . g4+4 ORA 7„ - 54" 4 /38 4 ., A ., . .4 . ,2 ' 4 " 68" 4"/48" WOI:firi0 0 „, 4" 50" 22" 4" 60" 30" 4" 63" 33 4" 68 35" 4" 74" 41" 4" 77" 45" '/ sr MI 4 4" 45" 4"/42" 4" 54" 4"/50" 4" 60" 4"/56" 6" 68" 4"/60" 6" 72" 4"/65" 8" 78" 4"/70" ' 4 (AiliWkOtiii '4 - - - 4" 60" 25"/30" 4" 66" 32"/33" 4" 73 34"/35" 4" 76" 38"/41" 4" 81" 42 /45" (,,I;T ,r;;;' : ; , ;01,117,0040 ? "1,,,? , :? - - - 4" 54" 18"/50" 4" 60" 18 /56 6" 68" 18"/60" 6" 72" 18"/66" r 78 18 /70 FLUE . '., aokNEcric*:: . GAS , : CONNECTION ELECTRICAL .' RATING, :::TOBE:'- ,,, ' 'DIAMETER ,, . : :,' IGNITION ,:" '.- ',.".., 'SYSTEM .,, IlikG , 4" (O.D.) 1/2" NPT 120VAC, 60Hz. 1.0 amp run 5.0 amp start 4" Hot surface (Three-try) Nat. 4.6" W.C. L.P. 11.0" W.C. „ , 1 0 6 EL -*-:'7 i-:: ---`"-;" '• BTLI/Hil - : f..- (Natural Gas ' '‘!.,,.----- iieLFii' ',..',-`, ,•• • ,-..:•• ..,,,, Aott,t„ , .•,, 4. 95 lbs. 9 130 lbs. 130 lbs. CTH2-100 CTH2-125 CTH2-150 100,000 125,000 150,000 165 lbs. 200 lbs. 235 lbs. To' =I Jiiss'Aill5=14*-W. -, D ' .... ..... ." .:...:,, iiIiii0:Gii,i.:;•:-":.':::::' iii 0.y•1••••: ,.„.. ..,• . • • ,-• .. SHIPPING "`"::•:;;;;;,."MlE;07q.:';:::.;',...." ..:,.., • • .... ...... ....• . CTH2-40 CTH2-60 CTH2-80 40,000 60,000 80,000 95 lbs. 9 130 lbs. 130 lbs. ...',...cii -- ":0 ";;;Iic.iiiiii■il.,';', :I.**. :7411:31E111:2211C3 :ft*. 1:25 :•: 1E9= To' =I Jiiss'Aill5=14*-W. 1t . 401.:1110-10 - 54" 4 /38 4 " 60" 4 /42 4 " 68" 4"/48" 4" 72" 57 4 " 78" e/62" d}4;2i- ( pofq-rs A rrAcieli CTH2 SIPES ® SPECIFICATIONS • L Top View DIMENSIONS (Standard Models) STRAIGHT CTH2.40 (11' 10") CTH2-60 (21' 4") CTH2-80 (21' 4") CTH2-100 (31' 4") CTH2-125 (41' 4") CTH2-150 (51' 4") U-TUBE r31:. CTH2•60 (13') CTH2-80 (13') CTH2-100 (18') CTH2-125 (23') CTH2-150 (28') *See installation manual for complete information. Roberts-Gordon, Inc. Subsidiary of A.J. Industries, Inc. P.O. Box 44 • Buffalo, NY 14240-0044 Phone: (716) 852-4400 • Fax: (716) 852-0854 CALL TOLL FREE: 1-800-828-7450 IN NEW YORK: 1-800-221-0955 CLEARANCES TO COMBUSTIBLES* REFLECTOR HORIZONTAL REFLECTORS HORIZONTAL 32" 1 6" j REFLECTORS TILTED 11%" REFLECTOR TILTED 11 11143'' ENERGY SAVING PRODUCTS, INC. 889 GARDEN OF EDEN RD. SEDRO WOOLLEY, WA 98284 1200) 858-2700 24" 24" HEATER TILTED