HomeMy WebLinkAboutPermit 0532-M - BOEING #9-1010532-M 91-101
BOEING #9-101 HVAC
9725 EAST MARGINAL WAY SOUTH
.
:;::::::::::::::::::::::::::::::;:::::::::;:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::;::::::::::::::::::::::;;:::g:::::;:::::::::::::::::::: a .
Boeing
" 1988
ADDRESS:
FIRE PROTECTION: 01211ZEMIDDetectors N/A
•
Seattle, WA !ZIP: 98124
•NDI I• • h: : . :. • • : : h:A. • .: 1:tv
SUITE NO.
- ; • 1 ■4 A N, Boeing 119
A .
BUILDING
APPROVED FOR zwir
ISSUANCE BY: AMIN OFFICIAL
•
DATE:
_
TYPE OF WORK: a New/Addition Cl Modifications
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions
of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of
this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating construction or the performance of work. I am authorized to sign for and obtain this mechanical permit.
PERWilf•kill MIMI
DATE: -/, -
.7----
PRINT NAME: z , 2, . - : - . - - /1/: r
,
COMPANY: ‘ , - , , ..„:.:d-__
PROPERTY OWNER:
Boeing
PHONE: 544
ADDRESS:
SITE ADDRESS: 9725 E Marginal Wy S
Seattle, WA !ZIP: 98124
CONTRACTOR:
SUITE NO.
- ; • 1 ■4 A N, Boeing 119
ADDRESS:
P.O. Box 3707, M/S 46
VALUE OF WORK: $ 2,200.00
_
TYPE OF WORK: a New/Addition Cl Modifications
n Repair
(
) Other:
DESCRIPTION OF WORK: Install fan and hood.
PROPERTY OWNER:
Boeing
PHONE: 544
ADDRESS:
P.O. Box 3707, M/S 46
Seattle, WA !ZIP: 98124
CONTRACTOR:
Boeing
'PHONE: 544
ADDRESS:
P.O. Box 3707, M/S 46
Seattle, WA IZIP: 98124
WA. ST. CONTRACTOR
N/A
EXPIRATION DATE: N/A
CITY OF TUKWILA
Department of Community Development Building
6300 Southcenter Boulevard, Tukwila WA 98188
(206) 431-3670
MECHANICAL
PERMIT NO 0 55;Q
DATE ISSUED:
DATE
REQUIRED INSPECTIONS PHONE NO. APPROVED
1 - Rough-InNents/Ducts 431-3670
2 - Fire Final
3- Planning Final
4 -
5 - Mechanical Final
OTHER AGENCIES:
L)-is-q)
575-4407
431-3680
MECHANCCAL PERMIT
(POST WITH PLANS IN A CONSPICUOUS LOCATION)
Division
7777
FEES . AMOUNT
Basic Permit Fee $15.00
Unit Fee
Pla Check Fee
Plan Check No.:
91
RECEIPT #
CflQ Cl
DATE
(rC
0
speot100 'i;:stile(10124 hoti
INSPECTOR
DATE(S)
CORRECTION NOTICE ISSUED
Plumbing/Gas Piping - King County Health Department (296-4732)
Electrical - Washington State Department of Labor and Industries (277-7272)
This permit shall become null and void if the work is not commenced within 180 days from thej
i:i:oi:i'•!:ii':Issildnotroitiiitthw.Woricis::suspended:Oseabancionedfor apetiodotiilladayi:11...00#7044t1n.p.ecti.
PERMIT NO.
CONTACTED
p rC
DATE READY
DATE NOTIFIED
2nd NOTIFICATION
(CY 1T C O
BY:
(init.)
BY:
(init.)
r if3
PERMIT EXPIRES
AMOUNT OWING
c 2_Q -
�� . �
3RD NOTIFICATION
BY:
(init.)
( MECHANICAL PERMIT
APPLICATION TRACKING
PLAN CHECK
NUMBER
PROJECT NAME
r B0 - €.:\ n C HO )
SITE ADDRESS 5
ct YYtar cz`.l
INSTRUCTIONS TO STAFF
• Contacts with applicants or requests for information should be summarized in writing by staff so that
any time the status of the project may be ascertained.
• Plan corrections shall be completed and approved prior to sending on to the next department.
• Any conditions or requirements for the permit shall be noted on the plans or summarized concisely
in the form of a formal letter or memo, which will be attached to the permit.
• Please fill out your section of the tracking chart completely. Where information requested is not
applicable, so note by using "N /A ".
DEPARTMENTAL REVIEW
"X" in box indicates which departments need to review the project.
DE 'PA.RTMEt
BUILDING -
initial review
O FIRE
O PLANNING
O OTHER
BUILDING -
final rpviAw
REVIEW COMPLETED
TC IPJ i. .......
6/11/f/A
(ROUTEDL
INIT:
INIT:
INIT:
CONSULTANT:
FIRE DEPT. LETTER DATED:
U1R EM
Date Sent
FIRE PROTECTION: Sprinklers Detectors N/A
INSPECTOR:
ZONING:
SCREENING REQUIRED? fYes (l No
REFERENCE FILE NOS.:
UMC EDITION (year):
SUITE NO.
Date Approved -
1BAR/LAND USE CONDITIONS? ( Yes (1 No
09 17190
^'••.. :,• ' S R P O , v ; '.••
t> ' • I '...;:14..'
?N'
} � :� : {,,
:::. ' ,
BASIC' :J i<!
<..t.h r :
;
;4yt� K;
;', °> ; ;!C',!
UNITS FEE' >..�.:: ?:t >4:1
,<:<
£ f. `.t3,_
fi• •' ;;Xi:*:.
PLAN CI-(EC KIT EE' <&>.:415,
,l1 , ,�.. •a
, , 4< .:
. � .
, . .,,��::: >.;:�
1si:' 'f1��1.:1 • t 1.;
OTHER 1:,1 :4.:1(,ili, ".t}3.:v,::h•, { ��{ y:�Y:
•,:'�,
: 0 i y ) }. '£: tit
S.,i4 {../ . Yl: tk1�.�,1.:
t '£�•.:1
i1.M� .R:•ll :.
1..,. 1 'a. 1. f
I:�f1 1':�1 \�•�1:�t \I
:<.: �: ' :�11� i < ? 1 Y,: :i
• ::;: >i;<�: z:<z,::: <:. TOTALv:.>i >i
8k'Y:. Q. .
,: � ' �:'
:
I .v, t v . r
. 1. r,£: ,:1:< >:. >...fh::
''1�4 ' i x•�y k y
: . >.,..'.:�'...
.. TRI.E::.
::RATiNG/SIZE
t
F
<: NUMBER Of,' UNITS: .;�<'a'di i '; •
CENTRIFUGAL
600 CFM 1HP
1
BUILDING USE (office, warehouse, etc.)
QFFICE /MANUFACTURING
.
NATURE OF BUSINESS:
1
CITY OF TUKWILA
•
Department of Community Development - Building
6200 Southoenter Boulevard, Tukwila WA 98188
(206) 433-1849 PENROD JOB iiW10039 -02
PLAN CHECK
NUMBER
APPLICATION MUST BE FILLED OUT COMPLETELY
' .31TE ADDRESS SUITE #
; . .9725 E. MARGINAL WAY SO. BLDG. 49 - 101
PROJECT NAME/TENANT
i3OE IN'.; MILITARY AIRPLANES
[YPE OF WORK: New /Addition 0 Modifications
DESCIPIBE WORK TO BE DONE:
FAN 4ND Hnnr)
WILL THERE BE A CHANGE IN USE? GD No 0 Yes IF YES, EXPLAIN:
PROPERTY OWNER BOEING MILITARY AIRPLANES
ADDRESS
CONTRACTOR
ADDRESS P.O.BOX 3707 M/S 46 -87. SRATTTT,R,WA.
WA. ST. CONTRACTOR'S LICENSE It BOE INC - 294ML
. RCHITECT
t,DDRESS
IEREIM0ERTIFY? 1
(U E AND CORREO
:;ONTACT PERSON
P.O.BOX 3707, M/S 46 -87, SEATTLE, WA.
BOEING MILITARY AIRPLANES
RfFTNn MTT,T'T'A&Y ALQpr,ANFS
P.O. BOX 3707, M/S 46 -87, SEATTLE WA.
ID`
BUILDING OWNER SIGNATURE
OR
AUTHORIZED
AGENT
tFAl7: ANp f")G
AUTHORIZEb-T
PRINT NAME TERRY BFNNFTT
MECHANIC -'L PERMIT
APPLIeATION
Mechanical Fee Worksheet must also be filled out and attached to this
WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE
BUILDING? Q No 0 Yes IF YES, EXPLAIN:
I!
0 Repair
PLYYF•OR:T
VALUE OF CONSTRUCTION - $ 2,200.00
0 Other:
ADDRESS P.O. BOX 3707, M/S 46 -87, SEATTLE,WA.
TERRY BENNETT
FEES (for staff use only)
:K
PHONE (206) 544 - 2975
PHONE
2 (6) 544 -2975
ZIP TR174 -7 2n7
EXP. DATE
01 -01 -A3
PHONE (206) 544 -2975
I ZIP 98174 - 220.7 _
�SSA;f�IiwjTU
DATE
ZIP
98124-22
06 -04 -•1
PHONE
(2U) 544 - 2975
CiTYlZiP 98124 - 2207
PHONE (206) 544-2975
Ik alion,
.PPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill
out the application completely and follow the plan submittal checklist on the reverse side of this form. A completed
"Mechanical Permit Fee Worksheet" must accompany this permit application. Handouts are available at the Building
counter which provide more detailed Information on application and plan submittal requirements. Application and
• ire co•riolete'In' iidui iu•ud ac:eoled for plan review,
UILDING OWNER / AUTHORIZED AGENT If the applicant Is other than the owner, registered architect/engineer, or
contractor licensed by the Stale of Washington, a notarized letter from the property owner authorizing the agent
to submit this permit application and obtain the permit will be required as part of this submittal.
ALUATION OF CONSTRUCTION The valuation Is for the work covered by this permit and must be filled in by the
applicant. This figure is used for budget reporting purposes only and not to calculate your fees,
:£:PIRATION OF PLAN REVIEW Applications for which no permit Is Issued within 180 days following the date of
application shall expire by limitation. The Building Official may extend the time for action by the applicant for a
period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform
Mechanical Code (current edition). No application shall be extended more than once.
If you have any questions about our process or plan submittal requirements,
please contact the Department of Community Development at 433 -1849.
:ATE APPLICATION ACCEPTED
DATE APPLICATION EXPIRE
(a- ( 0 I
bi
011291110
vi i fr III uR trvILA
Department of Community Development - Building Division
6200 Southcenter Boulevard, Tukwila WA 98188
(206) 433 -1849
THIS WORKSHEET MUST ACCOMPANY
YOUR MECHANICAL PERMIT APPLICATION.
INSTRUCTIONS - Complete the worksheet,
indicating the number of units being installed
in each category, multiplied by the unit cost.
Then tally. the subtotal column highlighted at
the bottom of the worksheet. At time of
submittal, staff will calculate the remaining fees.
DESCRIPTION
UNIT COST
NO. OF
UNITS
X
TOTAL
COST
BASIC FEE
$15.00
1
Installation or relocation of each forced -air gravity -type furnace or
burner, including ducts and vents attached to such appliance, up to and
including 100,000 Btu /h.
$9.00
X
2
Installation or relocation of each forced -air or gravity -type furnace or
burner, including ducts and vents attached to such appliance over
100,000 Btu /h.
$11.00
X
3
Installation or relocation of each floor furnace, including vent.
$9.00
4
Installation or relocation of each suspended heater, recessed wall heater
or floor- mounted unit heater.
$9.00
X
5
Installation, relocation or replacement of each appliance vent installed and
not included in an appliance permit.
$4.50
6
Repair of, alteration of, or addition to each heating appliance,
refrigeration unit, cooling unit, absorption unit, or each heating, cooling,
absorption, or evaporative cooling system, including installation of
controls regulated by this code.
$9.00
X
7
Installation or relocation of each boiler or compressor to and including
three horsepower, or each absorption system to and including 100,000
Btu /h.
$9,00
X
8
Installation or relocation of each boilenor compressor over three
horsepower to and including 15 horsepower, or each absorption system
over 100,000 Btu /h and including 500,000 Btu /h.
$16.50
X
, 9
Installation or relocation of each boiler or compressor over 15
horsepower to and including 30 horsepower, or each absorption system
over 500,000 Btu /h to and including 1,750,000 Btu /h.
$22.50
X
10
Installation or relocation of each boiler or compressor over 30
horsepower to and including 50 horsepower, or for each absorption
system over 1,000,000 Btu /h to and including 1,750,000 Btu /h.
$33.50
X
11
Installation or relocation of each boiler or refrigeration compressor over
50 horsepower, or each absorption system over 1,750,000 Btu /h.
$56.00
X
12
Each air - handling unit to and including 10,000 cubic feet per minute,
including ducts attached thereto. (NOTE: This fee shall not apply to an
air - handling unit which is a portion of a factory- assembled appliance,
cooling unit, evaporative cooler or absorption unit for which a permit is
required elsewhere in this code.)
$6.50
X
13
Each air - handling unit over 10,000 cfm.
$11.00
X
14
Each evaporative cooler other than a portable type.
$6.50
X
I 15
Each ventilation fan connected to a single duct.
$4.50
X
L {j 50
16
Each ventilation system which Is not a portion of any heating or
air - conditioning system authorized by a permit.
$6.50
X
17
Installation of each hood which is served by mechanical exhaust, including
the ducts for such hood.
$6.50
X
0•E0
18
Installation or relocation of each commercial or industrial -type incinerator.
$11.00
X
19
Installation or relocation of each commercial or industrial -type incinerator.
$45.00
X
20
Each appliance or piece of equipment regulated by the code but not
classed in other appliance categories, or for which no other tee is listed in
this code.
$6.50
.
X
SUBTOTAL (unit fee)
LQ(p,0
PLAN CHECK FEE Vt,
(,P .50
GRAND TOTAL
$ G
MECHANI AL PERMIT
FEE W RKSHEET
CITY OF TUKWILA
6200 SOUTIICENTER BOULEVARD, TUKWILA, WASHINGTON 98188
Plan Check #91- 101 -M: Boeing #9 -101
9725 E Marginal Wy S
PHONE N (206) 433.1800 Cary L. VanDuscu, Mayor
THE FOLLOWING COMMENTS APPLY TO AND BECOME PART OF THE APPROVED
PLANS UNDER TUKWILA MECHANICAL PERMIT NUMBER 0,0a-101 .
1. No changes will be made to the plans unless approved by
the Architect and the Tukwila Building Division.
2. Electrical permit shall be obtained through the
Washington State Division of Labor and Industries and all
electrical work will be inspected by that agency (277-
7272).
3. All permits, inspection records, and approved plans shall
be posted at the job site prior to the start of any
construction.
4. Approval of this mechanical exhaust system is based on
the condition that this system is not, or will be used to
convey explosive or flammable vapors or any hazardous
materials as defined in Chapter 9, U.B.C.
5. All construction to be done in conformance with approved
plans and requirements of the Uniform Building Code (1988
Edition), Uniform Mechanical Code (1988 Edition), and
Washington State Energy Code (1990 Edition).
6. Validity of Permit. The issuance of a permit or approval
of plans, specifications and computations shall not be
construed to be a permit for , or an approval of, any
violation of any of the provisions of this code or of any
other ordinance of the jurisdiction. No permit presuming
to give authority or violate or cancel the provisions of
this code shall be valid.
PROJECT: F3o e. r.1 G 6 1- l o /
PERMIT NO. 05 3 Z - I'rN
SITE ADDRESS: G] ,.. .-t
DATE CALLED: FS'- C . '/
TYPE OF INSPECT ON: �--�....Q
''
DATE WANTED: , -- - ok/
SPECIAL INSTRUCT! . • Pvrd7 oK-- e cc,i. L -'co
REQUESTER: Q,,J 1414.6
PHONE NO.: 9 g- 243 q c.
_
INSPECTION RESULTS /COMMENTS: 5 (ILL 0
r
INSPECTOR: z- I DATE:. 2"' 6
Ch_ yC 1 A !FftlAegitta1ua»muurar.w�axox11a ,1 .Verbs ?,,,, :CE^.c!Mne✓_ N YEf3 ;t'; *. r,,,.: ti5 ...,. •., Mk•B;i ,.. E"G'Gt *:+,!:it:..k.,r. °f,;Y..i Yr a�st:'r *r?:tct^ :'t:i:: c':Y ,^Irzi�t, tvig t S nit.
....,.r .ds.. ux •"lla: "i:U:J4ti :t, 5,r.. s2t ^ne45;+`.�'t�•' .f : /t!•! ?� �. .. .. •
I
CITY OF TUKWILA
Dept. of Community Development - Building Division
Phone: (206) 431 -3670
INSPECTION RECORD
6300 Southcenter Boulevard — #100
Tukwila Washington 98188
L
PLAN REVIEW COMMENIS
Plan Check No.: C 11 - 101 - M Project: ` EIt1C. 0 9-101 MEE�C44.
REQUIRED INSPECTIONS
Z
3).4.0
w
to
a z(r
PP'
� O1�
Z
'0
fit.8
No changes will be made to the plans unless apprdved by the Architect
and the Tukwila Building Division.
2. Plumbing permit shall be obtained through the King County Health
Department and plumbing will be inspected by that agency, including all
gas piping (296 - 4722).
Electrical permit shall be obtained through the Washington State Division
of Labor and Industries, and all electrical work will be inspected by that
agency (277- 7272).
4. All mechanical work shall be under separate permit through the City of
Tukwila.
All permits, inspection records, and approved plans shall be posted at the
job site prior to the start of any construction.
6. When special inspection is required, either the owner, architect or
engineer shall notify the Tukwila Building Division of appointment of the
inspection agencies prior to the first building inspection. Copies of all
special inspection reports shall be submitted to the Building Division in a
timely manner. Reports shall contain address, project name and permit
number of the project being inspected.
7. All structural concrete to be special inspected (Sec. 306, UBC).
8. All structural welding to be done by W.A.B.O. certified welder and special
inspected (Sec. 306, UBC).
9. All high- strength bolting to be special inspected (Sec. 306, UBC).
10. Any new ceiling grid and light fixture installation is required to meet lateral
bracing requirements for Seismic Zone 3.
11. Partition walls attached to ceiling grid must be laterally braced if over eight
(8) feet in length.
12. Readily accessible access to roof mounted equipment is required.
13. Engineered truss drawings and calculations shall be on site and available
to the building inspector for inspection purposes. Documents shall bear
the seal and signature of a Washington State Professional Engineer.
14. Any exposed insulations backing material to have Flame Spread Rating of
25 or less, and material shall bear identification showing the fire
performance rating thereof.
15. Subgrade preparation including drainage, excavation, compaction, and
fill requirements shall conform strictly with recommendations given in the
soils report prior to final inspection (see attached procedure).
16. A statement from the roofing contractor verifying fire retardancy of roof
will be required prior to final inspection (see attached procedure).
All construction to be done in conformance with approved plans and
requirements of the Uniform Building Code (1988 Edition), Uniform
Mechanical Code (1988 Edition), Washington State Energy Code (1990
Edition),
18. All food preparation establishments must have King County Health
Department sign -off prior to opening or doing any food processing.
Arrangements for final Health Department inspection should be made by
calling King County Health Department, 296 -4787, at least three working
days prior to desired inspection date. On work requiring Health
Department approval, it is the contractors responsibility to have a set of
plans approved by that agency on the job site.
19. Fire retardant treated wood shall have a flame spread of not over 25. All
materials shall bear identification showing the fire performance rating
thereof. Such identification shall be issued by an approved agency
having a service for inspection at the factory.
20. Notify the City of Tukwila Building Division prior to placing any concrete.
This procedure is in addition to any requirements for special inspection.
21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8,
shall be special inspected.
22. All wood to remain in placed concrete shall be treated wood.
23. All structural masonry shall be special inspected per U.B.C. Section 306
(a) 7.
Validity of Permit. The issuance of a permit or approval of plans,
specifications and computations shall not be construed to be a permit for,
or an approval of, any violation of any of the provisions of this code or of
any other ordinance of the jurisdiction. No permit presuming to give
authority or violate or cancel the provisions of this code shall be valid.
25. A Certificate of Occupancy will be required for this permit.
• • • •••.
•
1.
Footings
2.
Foundation
3.
Slab /Slab Insulation
4.
Shear Wall Nailing
5.
Roof Sheathing Nailing
6.
Masonry Chimney
7.
Framing
8.
Insulation
9.
Suspended Ceiling
10.
Wall Board Fastening
11.
12.
13.
14.
Fire Final
15.
Planning Final
16.
Public Works Final
17.
Building Final
L
PLAN REVIEW COMMENIS
Plan Check No.: C 11 - 101 - M Project: ` EIt1C. 0 9-101 MEE�C44.
REQUIRED INSPECTIONS
Z
3).4.0
w
to
a z(r
PP'
� O1�
Z
'0
fit.8
No changes will be made to the plans unless apprdved by the Architect
and the Tukwila Building Division.
2. Plumbing permit shall be obtained through the King County Health
Department and plumbing will be inspected by that agency, including all
gas piping (296 - 4722).
Electrical permit shall be obtained through the Washington State Division
of Labor and Industries, and all electrical work will be inspected by that
agency (277- 7272).
4. All mechanical work shall be under separate permit through the City of
Tukwila.
All permits, inspection records, and approved plans shall be posted at the
job site prior to the start of any construction.
6. When special inspection is required, either the owner, architect or
engineer shall notify the Tukwila Building Division of appointment of the
inspection agencies prior to the first building inspection. Copies of all
special inspection reports shall be submitted to the Building Division in a
timely manner. Reports shall contain address, project name and permit
number of the project being inspected.
7. All structural concrete to be special inspected (Sec. 306, UBC).
8. All structural welding to be done by W.A.B.O. certified welder and special
inspected (Sec. 306, UBC).
9. All high- strength bolting to be special inspected (Sec. 306, UBC).
10. Any new ceiling grid and light fixture installation is required to meet lateral
bracing requirements for Seismic Zone 3.
11. Partition walls attached to ceiling grid must be laterally braced if over eight
(8) feet in length.
12. Readily accessible access to roof mounted equipment is required.
13. Engineered truss drawings and calculations shall be on site and available
to the building inspector for inspection purposes. Documents shall bear
the seal and signature of a Washington State Professional Engineer.
14. Any exposed insulations backing material to have Flame Spread Rating of
25 or less, and material shall bear identification showing the fire
performance rating thereof.
15. Subgrade preparation including drainage, excavation, compaction, and
fill requirements shall conform strictly with recommendations given in the
soils report prior to final inspection (see attached procedure).
16. A statement from the roofing contractor verifying fire retardancy of roof
will be required prior to final inspection (see attached procedure).
All construction to be done in conformance with approved plans and
requirements of the Uniform Building Code (1988 Edition), Uniform
Mechanical Code (1988 Edition), Washington State Energy Code (1990
Edition),
18. All food preparation establishments must have King County Health
Department sign -off prior to opening or doing any food processing.
Arrangements for final Health Department inspection should be made by
calling King County Health Department, 296 -4787, at least three working
days prior to desired inspection date. On work requiring Health
Department approval, it is the contractors responsibility to have a set of
plans approved by that agency on the job site.
19. Fire retardant treated wood shall have a flame spread of not over 25. All
materials shall bear identification showing the fire performance rating
thereof. Such identification shall be issued by an approved agency
having a service for inspection at the factory.
20. Notify the City of Tukwila Building Division prior to placing any concrete.
This procedure is in addition to any requirements for special inspection.
21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8,
shall be special inspected.
22. All wood to remain in placed concrete shall be treated wood.
23. All structural masonry shall be special inspected per U.B.C. Section 306
(a) 7.
Validity of Permit. The issuance of a permit or approval of plans,
specifications and computations shall not be construed to be a permit for,
or an approval of, any violation of any of the provisions of this code or of
any other ordinance of the jurisdiction. No permit presuming to give
authority or violate or cancel the provisions of this code shall be valid.
25. A Certificate of Occupancy will be required for this permit.
• • • •••.
•
CITY OF TUKWILA
Department of Community Development - Building Division
Phone: (206) 431 -3670
PROJECT:
ADDRESS:
DATE:
OCCUPANCY GROUP
TYPE OF CONSTRUCTION
LOCATION ON PROPERTY
BUILDING HEIGHT /# OF STORIES
FLOOR AREA
OCCUPANT LOAD
EXITING REQUIREMENTS
DETAILED REQUIREMENTS
OCCUPANCY
TYPE OF CONSTRUCTION
PART V, CHAPTER 23, U.B.C.
W.S.E.C.
CHAPTER 51 -10, W.A.C.
NOTES
PREPARED BY:
PLAN REVIEVI►
o66w3 q- tia
q tvvite 0)9
it cia.40 I 110(wf ?oemir
C•
PLAN CHECK
NUMBER
6300 Southcenter Boulevard — #100
Tukwila Washington 98188
j ATE: // , cfr
SYM'
- •�'' REVISION
SY
APPROVED
DATE
SYM
REVISION
BY
4.'.6P0
APPROVED
DATE
Ki
'
INSTALL F A N FaR''RaoF VENTS 4
RAD. ._:
4J p
'•
s 415 - 5 9
• L
I J5TALL CHEMICAL ETCH 3 H
E--.-...)C.
/4.5.90
K �
Pik T E S T ►IJ 8bll,I -oe.
J
2.7 -87
Pit
hc. n .r. ,r4.. D`,s.. 1
, � 0 6
F-.!c
6'•ip•9p
F'ELOCA Ete /L- ,40:Fy3 8327/3-0o
.AL ✓AU /4
R.DA•'
DM 1(.
2y
717'
Lt)1YYl
3 - )s - e6
/I - ) 7 S5
y -9 -kt
N1
'INSTALL t ill AU ST FAA)
Kl-tP
G .
CUT4OPEMNGe.,615 J013
-.
•. DO Woo
RAI SED Fot 128FER1;t1C£ OttJI3 85(&51 -GO
•�
oO 40Th IO
OR. !0/70
ACCEPTABILITY
THIS DESIGN
SPECIFICATION IS
AND /OR
APPROVED
�^
DEPT.
DAl'E
D F A ERVU SOt.I
2797 [Yh
SUBTITLE
ROOF PLAN — INTAKES & EXHAUSTS
LAST REVISI
DATET
CHECKED
SHEET —
% M ION
1
of
3
APPROVED BY
/
/ t„i� 44.,:,•,
2 I<-PJ5
-•
"'
MECHANICAL MASTER -
BLDG 9 -101 COI. A- 2/1 -22 D.C.
APPROVED
°a NO 0080 09
L............
APPROVED
DWG H° 109 -101 - 445 0
15
VENT FAN
RV-
VEN
O. A. I NTA
38'/(oL•
AHU el -
0 A. !NTA
1 0•.0"
- PLASTICS AR
T
5572o G .u. --
,a 32'cuRB
Q. INTAKE ---
3B/62
- PLASM& A
TALK U' /zo "rlSTh Aev. Io'nEJ
w /So° /21;° •v
3.c-
MACK
cony ARS
owe REF I I
3a134 O.
(e - ABv RLOF
(CAPPEn)
-a STACK
12 CURB
3•Q STACK
8(/ cvRe,
10Vp
I - . - EKH.FA ETLA, /RV52
34/295 K /2o
E. XH - T iLET RCCH 7 -
2u /Ib7t CF./12/16 R.0.
RV• ASP, trJ+
34/2 'Since -s'nev
RV.37 /CANV
1t7 -o"
HIGH
/�• HILH
ACK /3 HIGH
S1A "3 EXH.
¶•__ EXN -
20 "CU
N.
'BV RTGD
rTI 25/25 pucr
tJ w/G
c.4/34
srAc .
2Y2'Wu6
AN- 121STMK
4 A0 - 6"44 S1AC
50'50(C APPS
r
4J
GAPPED)
INLET
/E'ABV ROOF
- .27/20" SrAcs.
32'710' Cu"C3
! 2 -- 6' AP.. 4hor
CONDENSER U IT
lo'•o'
. ISLOWI:R
207- to1•L.OIt /M!
1ZV-
T O I L E T
ri
L2,
(CA.PF 0)
42/33
RM EXH -25/25
r-I
Li
EXH PAN
24 /1.1 UuLT
2b /•'2 CUvB
GAPPEG
X2
r 11I r 2 7
LJ lJ
RV-t
RV-13
O A.1 NTAK
UN
RV-14
RV -19 - °(_I
RV16
o.A INTAK -
UH
RV-27-.0
o.A. INTME
UM • 34-
RV• z8
(04:12000
RV-17-
O A INTAKE
V H -
RV -20
RV -15 9
16771,'
(CAPPED)
21' /21
(CAPPED)
0. --' p
EXHAUST FAN
M- tY 1
- O.A. INTAKE
t)1-1- 39
V FNr. UNIT
St -r Dwc KE F"7
RV
Rv -23
R.O. •' Y5 -.'
(TYP!CAL 4)
RV•25•"
.e
7'CURB
S.G.
PTO
3rf G.N.
40' Cova
RV•4q- -
VENT FAN
RV-SO
VENT. FAN
10'•o'
(r P:PPFD)
136130 0.3W
(CAFPCD)
138132 - CUR•
(GAPPED)
(cAPPeD)
RV-35
1 LLVM.
20/20
317 7' CURS --
(CAPPED)
33 /3I'
(GAPPED)
37/31 . CURB
(GAPPED)
56756 -- .
(CAPPED
=+7 57'cvR6 ----
(CAPPED)
E6 /S6" I i
(CAPPFO)
SS /36•CURe
(CAPPED)
OR OFFICE
VGT
O.A. /2NDFE IFCICE
13113 R.O.; 12' 2
5'V/0:1V 1200
EXHAUST-'
29 /73'cuee.
- O.A. INTAKE
AHU• 33
93' /32
NTAVE
ELt EP
2" R.O.
kV -12
5'6" 8'
qty
;
ROOF PLAN
SCALE: I " :40'
50 S0'CUCB
( APPED)
O.A. MTAKE
r3V 44"
\ [c Ayer o)
�tI Z
13P� uRB AIR RELIEF
(CARVED) 60'/92' RA.
."
13a /32CAP
- IS8 /szoas
CD' (
AIR,INTAKE
59 /59 "Culls
AIR RELIEF, ((LAPPED)
6e/120" \
0
AIR RELIEF
443 192'r 0
- IOE
(cn Pet)
2
FACILITIES DEPARTMENT
--an. INTAKE_
.:se " /3L' R 0
-EXtl FAN
24/26 Cuaa
68 /92'Cue8
(cAPPeO)
❑ AUBURN, WA. 98002
❑ EVERETT, WA. 98201
❑ KENT, WA. 98031
❑ PORTLAND, OR. 97220
❑ RENTON, WA. 98055
SEATTLE, WA. 98124
1 111 III III III III 111 111 ICI 111 III III 111' III I I
III Iji ljE III III 11 Ili ijl III 111 111 III III III III III I II III IIIIIII III 1111111 III - 111 III III III Ili III111 111 III
I . -.
lllllllllf� II►IIIIIIIII'III Ifllf�lflflfljll
0 " " " MO1 1 2 3 4 5 6 7 8 9 10 11 ate. • 12
NOTE: If the microfilmed document is less clear than this
' . notice, it is due to the quality of the original document.
OE 6z eG Le 92 Sz v2 Cz 22 t2 Oz 6t DI Lt gt St in El 21 It OI 6 8 L 9 S 7 C e I n. 0
1illil11111uiingi1nnhln1i11ililli1nnlnn1iiiiluuii1111 i1 millw i idnn{ nningiplihmli !illmilmllnliliiilhinini lillitilmililnhiii1nlllu�ulilnii1iiului 1111i111milmilliiduulu milli lhn lnu' i
�r ,� # x J" - r r Inu�uilhm�unhln�nlilnn�imin.I�
- • e
FILE COPY
Date
Peon No
533 -rn
GENERAL • NOTES
A. THIS WING U REF OWCm4
FOP, ROOF DRA BETWSE EN PERSEDES GOL A /l
SEE OWG REF. 3 FOR DIMENgIOUED LOCATIONS
OF 2001= OPENIN&S,COL 0-5/19-22.
C. SEE DWG REF 5 FOR Hf.V UNITS 5ELOVV ROOF
OE t'J EN COL5 "A- D/11 -19.
D. SEE_ DW; . REF 6 FoR Hi UNITS 13ELGW f2cor
13ErWEEn1 CcLS X- Z/ I
E. SEE REF DW(,59i10 FOR OUTSIDE AIR INTAKE
DETAILS (3ETINEEAI COLS A - R /1
F. 5E DW H FOR DETAILS O>" RELIEF
VE MAR " R' BETWEEN! COLS Pt— /1-19.
G. OP MARKED "F " ARE STANDARD INTAKES
F OR REF FvrL/RE - USE.
H. SEE REF 7 FOR H‘. ' UNITS 3ELOW ROOF
$ETWEEN COLS R /I -19.
U. SEE DWG. 109 - 101-4450 FOR SECTION
SHOWING OPENINGS e 14 ( SECTION B)
@ Mfit (SECTION A)
CON STRUCT I O N NOTES
SEPARATE
PERMIT AND ELx
APPROVAL
REQUIRED
R.O.
S. G.
F
G.N.
R.N.
us
N5 SP-F,
(FA ri6 '"th Oc,ci
LEGEND
ROOF OPENING
SECURITY GRILLE
FUTURE USE CAPPED
G005F_ NEC. V
LOUVERED RELIEF Hoop - 42'x34'
O. A. INTAKE
1ST FLOOR -
SEGOIJO FLOOR
ROOF- OPENING - et X 38"
SEE REF I FoR DETAILS
RELIEF HOOD -4')<20' TYPICAL
I understand that the Plan Gk approvals are
r+,t -t 9 Irrnrc acrd Arak OS: and approval
plans does no authorize the ration of ally
adopted code or ordinance. Receipt of contractor 0.A INTAKE O (`I LY
copy of approved plans aclS9ow)edgad. R.O - 6' - 6''t( V
O.A. INTAKE -I-4i, V UNIT
R.O.- (o' (a" x5
R F DWGS
01430-N101-A60
2)K209 101-(o0O/0 -
3) PR- 1840-030 -4 - LOL D- 5/20-22.
4) b,30- 17/IO1-2O9 (`O
5)61 -215 -COL A-Obi - 19
6)6508-0/203 -Co:- X -2• /9 -19
7)6130 - /2os
8� (0130 -D /101 -213 CITYOFTUKWIA
6130 0/101-210
10 )b 1 $O - D /101 =2II
u)ra13o- D /lol-212
12 &130 -p /r0i =217
i9 �SK• 35 521o3g5
RECEIVED
d.,
CITY OF IMP APPROVED J IJ I 11 1991
• fJI
B • G i r
JUN 0 6 1yy1
PERMIT CENTER
Ir1
•
RECEIVED
CITY OF TUKWILA
JUN C 6 1991 :
Rc ATE LiDLITIE5 CIF
00 .003 4076 OAIG. 10/76
REVISION
1E3/1.C.
18/20
Y APPROVED DATE
D 11FCORD DPAWII\'G ISS11FP -r OWMFR GJ S
APPROVED
OATS
418196
9-14.96
FINISH FLOOR
(UNLESS oTHERWtS
A.AtA.S Nar>p)
,( MEZZANINE
HUMIDIFIER
THICK
S",aF-AR WALL
FLOOR To
CeILING) TuRra11.IG1
lIkaz
jF CU2 1
8"d (New)
CHECKED
APPROVED
REVISION
PLAN
FACILITIES DEPARTMENT ❑ PORTLAND, OR. 97110
, ACCEPTAStLITY
THIS DESIGN AND /OR
SPECIFICATION Is APPROVED
APPROVED CY
DEPT.
SHEAR WALL VJ/
Duct
JOB NO.
SYMBOL DATE
ANNEX ALTERATIONS
THE BOEING COMPANY;.-
DEVELOPMENTAL CENTER . SEATTLE, W
CITY OF TUKWIIA
APPROVED
LAST REVISION