Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit 0534-M - CONTEL
0534-M 91-109 CONTEL HVAC 925 INDUSTRY DRIVE : . comp vpicgq::::::::::::;::::.;::::::::;::.:::::::::::::::::::::::::::::::i:::::::::::i:::::::::::,::::::::::::::::;::::::ww::::::::::ig::::::::::::::11:::i:::;:::;::::::::::::::wili:::::::::::: UMC e •k :: 1988 FIRE PROTE TION: IIIIMMEMODetectors OREN A • •; New/Addition Modifications . . Re•air • Other: IZIP! 98188 CONDITIONS (other than noted on or attached to permit/01;6i): .....,....... . !PHONE: 575-8051 ADDRESS: (1 1 APPROVED FOR , ,, 9 , BUILDING . . ... --.. ISSUANCE BY: / 2 ,.......-........ OFFICIAL c) , ( ; / ,. DATE: 4 -/ 6 — 7 LICENSE NO, SEAAII206JQ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this mechanical permit. it 0 SIGNATUREAlk&L. U IU., DATE: '% / i 1 PRINT NAME: ___L)1L,1 tc1,_ nfk, L e 0 ,Q. ,9_,G, COMPANY: AA..-6 - .LI/t_4_. . 4.-CA / ::::::::::::::::::;: SITE ADDRESS: 925 Industry Dr SUITE NO. -;• L A L , a ,. Ai Contel VALUE OF WORK: $ 450.00 A • •; New/Addition Modifications . . Re•air • Other: IZIP! 98188 o ; - 4,11 oFWORK: Installation of one 100 C.F.M. bathroom exhaust fan. Sea-Aire, Inc. !PHONE: 575-8051 ADDRESS: PROPERTY OWNER: Koll Company PHONE: 575-0765 ADDRESS: 601 Strander Boulevard, Tukwila, WA IZIP! 98188 CONTRACTOR: Sea-Aire, Inc. !PHONE: 575-8051 ADDRESS: 906 Industry Drive, Tukwila, WA !ZIP: 98188 WA. ST. LICENSE NO, SEAAII206JQ 1EXPIRATION DATE: 4-30-92 CITY OF TUKWILA Department of Community Development - Building Division •.6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431-3670 MECHANICAL PERMIT NO. DATE ISSUED: - Mechanical Final OSI3L-1 Lc) (- tlea DATE DATE(S) APPROVED INSPECTOR CORRECTION NOTICE ISSUED REQUIRED INSPECTIONS PHONE NO. 1 - Rough-in/Vents/Ducts 431-3670 2 - Fire Final 575-4407 3 - Planning Final 431-3680 431-3670 MECHA CAL PERMIT (POST WITH PLANS IN A CONSPICUOUS LOCATION) • -I ,t AMOUNT B Unit Fee Plan Check No.: 91 OTHER AGENCIES: Plumbing/Gas Piping - King County Health Department (296-4732) Electrical - Washington State Department of Labor and Industries (277-7272) is permit shall become null and voi t it 07e: cornropnced,:womi.lsp.. from thqi iisirai74'.:Orif the work iStusPended..'04abandoned,fot 0:00#0 e c tl oi * PERMIT NO. CONTACTED I yy � ` � c� .C2._ DATE READY DATE NOTIFIED ( t � ' 1 �� s Lt.r l�` q \ (init.) PERMIT EXPIRES 2nd NOTIFICATION BY: (init.) AMOUNT OWING &J qc "J 1 , 3 j� 3RD NOTIFICATION BY: (init.) f MECHANICAL PERMIT APPLICATION TRACKING PROJECT NAME e fon+e ( SITE ADDRESS P LAN CHECK NUMBER q 1— 1cfim INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. P RTMENT BUILDING - H.- I initial review O FIRE O PLANNING O OTHER M BUILDING - final rAviAw G 16 REVIEW COMPLETED U1REME CONSULTANT: Date Sent C; lg - `/IK. P. INIT: INIT: ROUTED INIT: G L�. (ASS FIRE DEPT. LETTER DATED: INIT: REFERENCE FILE NOS.: t � UMC EDITION (year): J SUITE NO. %<'C`C.MMENTS! Date Approved FIRE PROTECTION: Sprinklers S Detectors N/A INSPECTOR: ZONING: IBAR/LAND USE CONDITIONS? f )Yes J) No SCREENING REQUIRED? fYes (l No 08/17/90 SITE ADDRESS SUITE # 9 5 ��'2 j 772 Y vg. & _t &. a 7 VALUE OF CONSTRUCTION - $ °° ./ .SO PROJECT NAME/TENANT C ©N TCL -- TYPE OF WORK: ❑ New /Addition Modifications ❑ Repair [] Other: DESCRIBE WORK TO BE DONE: nV s rag e 7 / / 0t) C. F /1 9/1 .Xr,`ffurr /v tYP E:,. :RATING /SIZE NUMBER OF UNITS A/ c9 7 - 0i1/ . Q 7/ o r'7 Ci c. ,c M.) / WA. ST. CONTRACTOR'S LICENSE #C _�i9 -_ 1.. _ 0G, -cr- EXP. DATEy 70 ,a ARCHITECT PHONE BUILDING USE (office, warehouse, etc.) w e ,e. ft-C— D�� = iC-- NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE ?_No ❑ Yes IF YES, EXPLAIN: WILL THERE B TORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? No ❑ Yes IF YES, EXPLAIN: PROPERTY OWNER K© __ ep/t_i/9. n/%'' PHONE_, --7.5 . Q 7 C.,S ADDRESS C 0/' �i y ,aG - V.2) ZIP f ��j�'�' CONTRACTOR PHONE ���rg3,s -i _(4// -��C ADDRESS 9aC - Z7,..,ip)_9'Tse_f' Z• L v /�r9-- ZIP w,/cfp WA. ST. CONTRACTOR'S LICENSE #C _�i9 -_ 1.. _ 0G, -cr- EXP. DATEy 70 ,a ARCHITECT PHONE ADDRESS ZIP I DESCRIPTION AMOUNT RCPT # DATE IBASIC PERMIT FEE .t7C� UNIT(S) FEE 4., .4 PLAN CHECK FEE L{ ; OTHER: TOTAL - ..: (9 35<' CITY OF TUKWILA Department of Community Development - Building Division 6200 Southcenter Boulevard, Tukwila WA 98188 (206) 433 -1849 PLAN CHECK ^ � NUMBER 4 - (o q - APPLICATION MUST BE FILLED OUT COMPLETELY MECHAN" SAL PERMIT APPLICATION Mechanical Fee Worksheet must also be filled out and attached to this lication. PER KN© Y CERTIFY CORREC BUILDING OWNER OR AUTHORIZED AGENT SIGNATURE PRINT NAME ADDRESS FEES (for staff use only) DATE PHONE - 7S F30S/ CITY /ZIP - - im/ � 4 CONTACT PERSON ( PHONE S/ APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. A completed "Mechanical Permit Fee Worksheet" must accompany this permit application. Handouts are available at the Building counter which provide more detailed inforrnatiol l on application and plan submittal requirements. Application and Plans must be complete In order to be accepted for plan review. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 433 -1849. DATE APPLICATION ACCEPTS ID C I DATE APPLICATION EXPIRES 03/29/99 S3MITTAL CHEC' IS MECHANICAL 0 Completed mechanical permit application (one for each structure or tenant) Two (2) sets of mechanical plans, which include: Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) • Floor plan • System layout • Elevations (for roof mounted equipment) Note: Hood and duct systems require a building permit for the duct shaft. ,1 CITY UI= TUKWILA Department of Community Development - Building Division 6200 Southcenter Boulevard, Tukwila WA 98188 (206) 433 - 1849 THIS WORKSHEET MUST ACCOMPANY YOUR MECHANICAL PERMIT APPLICATION. INSTRUCTIONS Complete the worksheet, Indicating the number of nits being installed In each category, multiplied by the unit cost. ; Then tally; the subtotal column . highlighted at the bottom of the worksheet , At time of submittal, staff will calculate the remaining fees. DESCRIPTION UNIT COST NO OF UNITS X TOTAL COST BASIC FEE $15.00 1 Installation or relocation of each forced -air gravity -type furnace or burner, including ducts and vents attached to such appliance, up to and including 100,000 Btu /h. $9.00 X 2 Installation or relocation of each forced -air or gravity -type furnace or burner, including ducts and vents attached to such appliance over 100,000 Btu /h. $11.00 x 3 Installation or relocation of each floor furnace, including vent. $9,00 x 4 Installation or relocation of each suspended heater, recessed wall heater or floor - mounted unit heater. $9.00 X 5 Installation, relocation or replacement of each appliance vent installed and not included in an appliance permit. $4.50 x 6 Repair of, alteration of, or addition to each heating appliance, refrigeration unit, cooling unit, absorption unit, or each heating, cooling, absorption, or evaporative cooling system, including installation of controls regulated by this code. $9.00 X 7 Installation or relocation of each boiler or compressor to and including three horsepower, or each absorption system to and including 100,000 Btu /h. $ X 8 Installation or relocation of each boiler or compressor over three horsepower to and including 15 horsepower, or each absorption system over 100,000 Btu /h and including 500,000 Btu /h. $16.50 X , 9 Installation or relocation of each boiler or compressor over 15 horsepower to and including 30 horsepower, or each absorption system over 500,000 Btu /h to and including 1,750,000 Btu /h. $22.50 X 10 Installation or relocation of each boiler or compressor over 30 horsepower to and including 50 horsepower, or for each absorption system over 1,000,000 Btu /h to and including 1,750,000 Btu /h. $33.50 x 11 Installation or relocation of each boiler or refrigeration compressor over 50 horsepower, or each absorption system over 1,750,000 Btu /h. $56.00 X 12 Each air - handling unit to and Including 10,000 cubic feet per minute, including ducts attached thereto. (NOTE: This fee shall not apply to an air - handling unit which is a portion of a factory- assembled appliance, cooling unit, evaporative cooler or absorption unit for which a permit is required elsewhere in this code.) $6.50 X 13 Each air - handling unit over 10,000 cfm. $11.00 X 14 Each evaporative cooler other than a portable type. $6.50 X 15 Each ventilation fan connected to a single duct. $4.50 1 X ti 16 Each ventilation system which is not a portion of any heating or air - conditioning system authorized by a permit. $6.50 X 17 Installation of each hood which is served by mechanical exhaust, including the ducts for such hood. $6.50 X 18 Installation or relocation of each commercial or industrial -type incinerator. $11.00 X 19 Installation or relocation of each commercial or industrial -type incinerator. $45.00 X 20 Each appliance or piece of equipment regulated by the code but not classed in other appliance categories, or for which no other fee is listed in this code. $6.50 X SUBTOTAL (unit fee) ( 5p PLAN CHECK FEE 1 . 4tg GRAND TOTAL 1 34 MECHAN AAL PERMIT FEE WORKSHEET CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD, TUKIVILA, WASHINGTON 98188 Plan Check #91- 109 -M: Contel 925 Industry Dr PHONE N (206) 433.1800 Cary L. VanDusen, Mayor THE FOLLOWING COMMENTS APPLY TO AND BECOME P �T OF THE APPROVED PLANS UNDER TUKWILA MECHANICAL PERMIT NUMBER Q Y)3 4 . 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (277- 7272). 3. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 4. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 5. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for , or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid: PROJECT: /I / _./ PERMIT NO. ' , 4 '- SITE ADDRESS: illoW.0711 /51s1!�0 TYPE OF INSPECTION: AA , , �� _ , „/ ir . i DATE CALLED: , -- t^q DATE WANTED: INAIBIL , r--- ; SPECIAL INSTRUCTIONS: REQUESTER: _ _J i., NO : 5 .,.. � O 5 INSPECTION RESULTS /COMMENTS: INSPECTOR: ' _ , ,'4-t., DATE: �f� -- f.-- 1 ,/ rNEVaivgxtorraemxrY+unemmsr, w.rar�wn.......�. war, Wn,, �v�a' wavwavasfAtvelu§ r +risx/Y+tKy�i!P'wu '1!yT!¢L'i t + ea' " alsrv4. r�! ilS.z:1.'L:tv„'':au +au,;,rvs,. CITY OF TUKWILA — Dept. of Community Development - Building Division Phone: (206) 431 -3670 xr 7T3tUi! if!!.i'iisf t':C "L'Tr,.;�(;,y INSPECTION RECORD V 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 12' x in Conference room 216 ft 12' x II'6' Office 138 sq ft 12' x 13'8' ORG. 164 /1 ft Usti., Id 14 1st myc4 12' x 16'1T Office 201 tiq ft X ityr Work area #1 356 tiq ft 1 1'3'x10' Office Q2egft 1 '3'x10' Office 4 125gft b 1 1'3'x10' Office 1 12sgft 5'4' x nostine G' r! 1 71'A' a loth Gu 0 to —. A 0 - a :3 0. Co o cn ea co 8. o Cl) CD Z ti Off. Ci o 0 as o m ai A.' 0 c — L O a c o ° CD ,s -. a, o °; a) ,1 o 'U ._ .—. Cl) ro 5. to) m r w a. - ° o ' i i t. 0• . D 2) 1 O C ' Q p N c)'= A cn m ; � co C1 -. N General Notes 1---- -- 12" 0' 13' Go- 45' 3' 25' 0' } 20' 3' I) Existing suspended ceiling and lighting to remain except as noted 2) Building has no fire sprinklers 3) Occupancy: Group B -2 4) Construction Type VIII S), All work to be done in accordance with 1988 .: UBC : & its revisions q.W } b'6' ro 3 2 O ro •; n: cn _. fly G. u M :. a J Q cD • w (OD cao (n a • G ,., CD o d �. a v) CD a. -< (D a p .r U O_ -1 5• N C1 • r ✓ a • r. •o o a a ▪ CD o i z , o -a 3 � ill a- ti V) M 0 C5 C, c iv m ' . : s a c7 O t0 O N O aj C CH A v C n R; -• a o - • ,'D , 0. - 0 6 - a 4 -q• 7 1.1 • A (D —' C, A CU ( t n . " 4 :ii- co 0 N Q: P. i '< • N b to General Notes I) Existing suspended ceiling and lighting to remain except as noted 2) Building has no fire sprinklers 3) Occupancy: Group B -2 4) Construction Type VN 5) All work to be done in accordance with 1988 UBC & its revisions m U) m m —I AML PW)TRY move TUK1LA VA 1 1111116 •t� 'n r- 0 u 13'4' x 67' EIcctriel Room 87yg --6' 7' 12' 0' fi 3' 6'1-- --- -q' 3' 12'xI7'�' Conference room 216egft 12' x II'6' Office 1385gft 12' x 13'8' ONie• 164 yq ft v4 location 12'x16'1' Office 201%i ft x 18'x' Work area *1 356 tiq ft 6 v ! r'4' I iL 1 - M. 'II 5'4' x 5'4' ahoy ikomm ±fq rA(A1 R�but� *MN doors ■d hi+1n 1 13' x 14'4' Receptionist 192 'q ft 13' Office q2 tigft x10' Of fice g12. tig 1'3'x10' Office g2 b tr N Relocate door r 20'3' x 32'1' Work area *2 663 t ft Poor to be moved i t in cavity 25' 0' } 20' 3' V. A b 12' f 13' ZION GON `7TKUGTION INC. Drawing scale I/8 in = I ft rH( -e moo 579-0 %7 PAX WA 575-14,3 THE KOL.L GOMf ANY CONT6. Tet44NT N'RO1M DAT .g ■MTRY DRrVC TLIM.A MA 40166 1'q' 10'6 DRAIN DY: APPROVED DY. DATE CITRECEIVED F T ILA JUN 1 7►199J PERMITCENTER 8210 8220 8832 QT -80 < QT -110 QT200 8110 8310 QT300 NUTONE FANS CODE DESCRIPTION LIST NUT 8070 8" through the wall Ian with telescoping sleeve. For 150.76 kitchens up to 80 sq. It., or other areas up to 200 sq. ft. Automatic shutter. 160 CFM, 4.5 sones. U.L. listed. NUT 8110 10" through the wall pull chain fan. 550 CFM, 6.0 204,76 sones, telescoping sleeve. For kitchens up to 125 sq. ft. other rooms to 310 sq. ft. U.L. listed. NUT 8210 7" vertical discharge ceiling fan, 210 CFM, 6.5 sones. 138.76 Round discharge opeining fits 7" round pipe. NUT 8220 8" vertical discharge ceiling fan, 170 CFM, 4,0 sones. 117.76 Fits 8" round pipe. NUT 8310 8" fan that installs in walls or ceilings. 180 CFM, 5.5 159.00 sones. Discharge through 3'I x 10 duct for kitchens up to 90 sq. fl., other rooms to 225 sq. ft. Extension hanger bars included. For 16" or 24" Q.I-. joists or studs. Will fit in a 2 x 4 wall. Use VS -60 or VS-64 switch. NUT 8510 10" fan that installs in walls and ceiling. 300 CFM, 7.5 204.76 sones, Discharge through 3I/4 x 10 duct for kitchens up to 150 sq. ft., other rooms to 375 sq, ft, NUT 8832 80 CFM, 3.5 sone ceiling fan exhausts to 3" round duct. 118.20 For bathrooms to 75 sq. ft., other rooms to 100 sq. ft. Use VS-64 switch. NUT 8870 80 CFM through the wall bathroom fan, 6.0 sones. 112.50 Automatic back draft damper, 7" round telescoping sleeve. For baths to 75 sq. It. White Louvre. NUT QT80 80 CFM, 1.5 sone bathroom ceiling Ian. Exhausts to 153.00 4" round white louvre. For bathrooms to 75 sq. ft. Use VS -64 switch... NUT QT110 110 CFM, 2.5 sone bathroom ceiling fan. Exhausts to 153.00 4" round duct. White Louvre. For bathrooms to 105 sq. ft. Use VS -64 switch. NUT QT200 Ceiling fan can be vented horizontally (2.5 sones, 220 202.66 CFM) or vertically (2.0 sones, 200 CFM) to 3 10" duct. Use VS -64 switch. NUT 0T300 Ceding fan can be vented horizontally (4.0 sones, 320 205.20 CFM) or vertically (45 sones, 300 CFM) to 3 x 10" duct. Use VS -65 switch. NUT RF -IN 650 CFM, I/w HP roof fan. All aluminum housing. 456.76 Uses 8" duct. NUT RF•40N 1000 CFM, '/e 1-IP roof fan. All aluminum housing. 610.50 Uses 10" duct. NUT WF -IN 650 CFM, I/9 HP wall fan. All aluminum housing, 432,76 with rainshield, Uses 8" duct. i 8210 8220 8832 QT -80 QT -110 RF 0 8110 8310 M \\\\\\ \‘‘ �t%\\\\\\\\\\ \\ 1 QT200 0T300 NUT WF•IN NUTONE FANS AF-1N CODE DESCRIPTION LIST NUT 8070 8" through the wall Ian with telescoping sleeve. For 150.76 kitchens up to 80 sq. IL, or other areas up to 200 sq. ft. Automatic shutter. 160 CFM, 4.5 sones. U.L. listed. NUT 8110 10" through the wall pull chain fan. 550 CFM, 6.0 204.76 sones, telescoping sleeve. For kitchens up to 125 sq. ft. other rooms to 310 sq. ft. U.L. listed. NUT 8210 7" vertical discharge ceiling fan, 210 CFM, 6.5 sones. 138.76 Round discharge opeining fits 7" round pipe. NUT 8220 8" vertical discharge ceiling fan, 170 CFM, 4.0 sones. 117.76 Fits 8" round pipe. NUT 8310 8" fan that installs in walls or ceilings. 180 CFM, 5.5 159.00 sones. Discharge through 3 10 duct for kitchens up to 90 sq. It. other rooms to 225 sq. ft. Extension hanger bars included. For 16" or 24" O.L. joists or studs. Will fit in a 2 x4 wall. Use VS.60 or VS -64 switch. NUT 8510 10" fan that installs in walls and ceiling. 300 CFM, 7.5 204.76 sones. Discharge through 3 10 duct for kitchens up to 150 sq. ft., other rooms to 375 sq. ft. NUT 8832 80 CFM, 3.5 sone ceiling fan exhausts to 3" round duct. 118.20 For bathrooms to 75 sq. ft., other rooms to 100 sq. ft. Use VS -64 switch. NUT 8870 80 CFM Through the wall bathroom fan, 6.0 sones, 112.50 Automatic back draft damper, 7" round telescoping sleeve. For baths to 75 sq. It. While Louvre _ NUT QT80 80 CFM, 1.5 sone bathroom ceiling fan. Exhausts to 153.00 4" round while louvre. For bathrooms to 75 sq. It. Use VS -64 switch. NUT QT110 :110 CFM, 2.5 sone bathroom ceiling fan. Exhausts to 153.00 4" round duct. White Louvre.. For bathrooms to 105 sq. ft: Use VS -64 switch. NUT QT200 Ceiling fan can be vented horizontally (2.5 sones, 220 202.66 CFM) or vertically (2.0 sones, 200 CFM) to 3'/4 x 10" duct. Use VS -64 switch. NUT 0T300 Ceiling Ian can be vented horizontally (4.0 sones, 320 205,20 CFM) or vertically (45 sones, 300 CFM) to 3 10" duct. Use VS -65 switch. NUT RF -IN 650 CFM, '/a HP roof Ian. All aluminum housing. 456.76 Uses 8" duct. NUT RF -40N 1000 CFM, '/u HP roof fan. All aluminum housing. 610.50 Uses 10" duct. 650 CFM, 1 /a HP wall fan. All aluminum housing, 432,76 with rainshield. Uses 8" duct. WF-1N 1. � i1 PLAN REVIEW COMMENTS Plan Check No.: l 1 ` [Oct A _ Project: CbtiL REQUIRED INSPECTIONS ✓ ` No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296 - 4722). X . Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be Inspected by that agency (277-7272). 4. All mechanical work shall be under separate permit through the City of Tukwila. All permits, inspection records, and approved plans shall be posted at the J 1 job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high - strength bolting to be special inspected (Sec. 306, UBC). 10. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 11. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 14. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296-4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, It is the contractors responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 • (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. 1. Footings 2. Foundation 3. Slab /Slab Insulation 4. Shear Wall Nailing 5. Roof Sheathing Nailing 6. Masonry Chimney 7. Framing 8. Insulation 9. Suspended Ceiling 10. Wall Board Fastening 11. 12. 13. 14. Fire Final 15. Planning Final 16. Public Works Final 17. Building Final PLAN REVIEW COMMENTS Plan Check No.: l 1 ` [Oct A _ Project: CbtiL REQUIRED INSPECTIONS ✓ ` No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296 - 4722). X . Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be Inspected by that agency (277-7272). 4. All mechanical work shall be under separate permit through the City of Tukwila. All permits, inspection records, and approved plans shall be posted at the J 1 job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high - strength bolting to be special inspected (Sec. 306, UBC). 10. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 11. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 14. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296-4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, It is the contractors responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 • (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit.