Permit 0622-M - SOUTHCENTER MALL - CHARACTER CORNER
(. CioR•ki ::::::1::: UMC EDITION (YEAR): 1988 CONTRACTOR: MetalSmiths Inc. 1PHONE: 362-3430 FIRE PROTECTION: ( )Sprinklers ( )Detectors (x)N/A CONDITIONS (other than noted on or attached to pelt L L7i /plans): APPROVED FOR ISSUANCE BY: Ld) }UJ\ BUILDING OFFICIAL DATE: /0 -6 -?/ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this mechanical permit. .---- . . DATE: / / h ( — 9 / COMPANY: frI4‘7772_..S;Y-// , SIGNATURE: PRINT NAME: 2. L) .J..0 f / At .0cs ,c) PROPERTY OWNER: Jacobs Visconsi Jacobs PHONE: 216-892-2300 ADDRESS: 25425 Center Ridge Road, Cleveland, OH 'ZIP: 44145 CONTRACTOR: MetalSmiths Inc. 1PHONE: 362-3430 ADDRESS: 7116 220th Street S.W. , Mount Lake Terrace, WA (ZIP: 98043 yv.A.3 . N-LQiRAI'-aaL.LQENjaENjQ DATE: 8-31-92 CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431-3670 MECHANICAL PERMIT NO. 0 Lo DATE ISSUED: MECHAWCAL PERMIT (POST WITH PLANS IN A CONSPICUOUS LOCATION) • FEES AMOUNT asjc Permit Fee $15.00 • TOTAL 35.00 Plan Check No.: 91-203-M RECEI FP*. SITE ADDRESS: 864 Southcenter Mall SUITE NO. PROJECT NAME/TENANT: Character Corner VALUE OF WORK: $ 6,000.00 TYPE OF WORK New/Addition Li Modifications ( ) Repair ( ) Other: DESCRIPTION OF WORK: Install two ton air conditioner with ductwork. DATE DATE(S) PHONE NO. APPROVED INSPECTOR CORRECTION NOTICE ISSUED REQUIRED INSPECTIONS 1 - Rough-in/Vents/Ducts 2 - Fire Final 575 4 431-3670 3 - Planning Final 431-3680 5 - Mechanical Final 431-3670 OTHER AGENCIES: Plumbing/Gas Piping - King County Health Department (296-4732) Electrical - Washington State Department of Labor and Industries (277-7272) This Perniit. shall become null and void if the work is not commenced within 180 days from the date �f isSUahCe; work is suspended or abandoned fora peijOd...of;180.'daYS. from the la PERMIT NO. CONTACTED rlYAD4 K DATE READY DATE NOTIFIED 2nd NOTIFICATION 3RD NOTIFICATION II `©_ 51 C t 1 B ^ p B BY: (Init.) BY: (Init.) PERMIT EXPIRES AMOUNT OWING 3 6 • cx> PLAN CHECK NUMBER C1-0)n-m INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". DEPARTMENTAL REVIEW "X" In box indicates which departments need to review the project. aEp :RT M NT,. O FIRE O PLANNING O OTHER PROJECT NAME SITE ADDRESS `S.(oL1 V (Lt1 r ifwi::.i'•ti.. O BUILDING - final rAViAw ° / . 4 REVIEW COMPLETED INIT: INIT: INIT: f MECHANICAL . APPLICATION TRACKING BUILDING - 1 %aL' lu initial review SRO EDP FIRE PROTECTION: INIT, CONSULTANT: Date Sent FIRE DEPT. LETTER DATED: ZONING: REFERENCE FILE NOS.: UMC EDITION (year): -E6� -- 0\a\f- a( ✓ �1n � RE SCREENING REQUIRED? fYes n No SUITE NO. Date Approved Sprinklers Detectors N/A INSPECTOR: IBAR/LAND USE CONDITIONS? )Yes n 08/17190 SITE ADDRESS `` SUITE # SO vtkc en .. �.1" 61.( 53(o VALUE OF CONSTRUCTION - $ CG� PROJECT NAME/TENANT --U 10.-M c_ 1 t=fZ 63 _1`14 =\Ia. TYPE OF WORK: Q New /Addition Q Modifications Q Repair Q Other: DESCRIBE WORK TO BE DONE: • - t — ►:lt -iThLL. Z -I-o vl n;Q- C�v\ck∎'1 1 w/D«ckL TYPE. , :. >:;: : ::. :. 0 >: :, : : :.: . »AATfNG/SiZE;': >:::t:: > >: ,.:•:::::::::; ..::::.::.:. ;::.. NUMEfERADF : >iJNITS:;: »..;;:: >:::;:: 1Th-Y _* D c> r &z H -A,A.3 Ica(c) c.L' T62_4-A) r 0 - C.e.-At U\ ;o✓k.1\ 2 - t - e 00 8y J CONTRACTOR --TA ; fi � ;13.. tjp BUILDING USE (office, warehouse, etc.) NATURE OF BUSINESS: E:Ig L.. S''1 WILL THERE BE A CHANGE IN USE? /l No 0 Yes IF YES, EXPLAIN: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? W#■lo Q Yes IF YES, EXPLAIN: PROPERTY OWNER -iltC t; )l t� f/n, ::::.AMOUNT` ; RCPT #•> PHONE 9 -4I -22i' ADDRESS ZIP CONTRACTOR --TA ; fi � ;13.. tjp PHONE .5G EXP. DATE Li 30 Z I Pq 3 s ._3 _9 ADDRESS :, --7 ,7 d "� h S � INN t ..T (..sue Pr WA, ST. CONTRACTOR'S LICENSE # M - 1 11 , y ;DESCRIPTION,: ::::.AMOUNT` ; RCPT #•> DATE.. BASIC :P.ERMIT::FEE . $15.00 UNITS) FEE < >:• ;13.. tjp PLAN CHECK FEE 'T. Q o OTHER` CITY OF TUKWIL� — � Department of Community Development - Building 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK NUMBER — 103— M APPLICATION MUST BE FILLED OUT COMPLETELY 1 HEREBY. CERTIFY:TH, T RUE AND CORRECT, BUILDING OWNER OR AUTHORIZED AGENT CONTACT PERSON SIGNATURE PRINT NAME HAVE READ AND, EXAMINED: THIS APPLICATION.: >THIS.P.ERMIT.. I AM AUTHORiZ�D 'TO AP:P. MECHANIC,- LL PERMIT APPLICATION Division ADDRESS --7 I t (p - - 1C- Mechanical Fee Worksheet must also be filled out and attached to this application. FEES (for staff use only) D::KNOW THE SAME: DATE -- Q PHONE CITY /ZIP yrn 6A.49 PHONE 3 3430 APPLICATION SUBMITTAL In order to ensure that our application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. A completed "Mechanical Permit Fee Worksheet" must accompany this permit application. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 431 -3670. DATE APPLI ATION CEPTED DATE APP ICATIO EXPIRES t/7 (/ 06/18/90 DESCRIPTION UNIT COST NO OF UNITS X TOTAL COST BASIC FEE $15.00 $4.50 SUPPLEMENT PERMIT FEE Installation or relocation of each forced -air gravity -type furnace or burner, including ducts and vents attached to such appliance, up to and including 100,000 Btu /h. $9.00 Installation or relocation of each forced -air or gravity -type furnace or burner, including ducts and vents attached to such appliance over 100,000 Btu /h. $11.00 X Installation or relocation of each floor furnace, including vent. $9.00 X 4 Installation or relocation of each suspended heater, recessed wall heater or floor- mounted unit heater. $9.00 X 5 Installation, relocation or replacement of each appliance vent installed and not included in an appliance permit. $4.50 X 6 Repair of, alteration of, or addition to each heating appliance, refrigeration unit, cooling unit, absorption unit, or each heating, cooling, absorption, or evaporative cooling system, including installation of controls regulated by this code. $9.00 7 Installation or relocation of each boiler or compressor to and including three horsepower, or each absorption system to and including 100,000 Btu /h. $ 9,00 8 Installation or relocation of each boiler or compressor over three horsepower to and including 15 horsepower, or each absorption system over 100,000 Btu /h and including 500,000 Btu /h. $16.50 X 9 Installation or relocation of each boiler or compressor over 15 horsepower to and including 30 horsepower, or each absorption system over 500,000 Btu /h to and including 1,750,000 Btu /h. $22.50 X 10 Installation or relocation of each boiler or compressor over 30 horsepower to and including 50 horsepower, or for each absorption system over 1,000,000 Btu /h to and including 1,750,000 Btu /h. $33.50 X 11 installation or relocation of each boiler or refrigeration compressor over 50 horsepower, or each absorption system over 1,750,000 Btu /h. $56.00 12 Each air - handling unit to and including 10,000 cubic feet per minute, including ducts attached thereto. (NOTE: This fee shall not apply to an air - handling unit which is a portion of a factory- assembled appliance, cooling unit, evaporative cooler or absorption unit for which a permit is required elsewhere in this code.) $6.50 X 1 c l 3 13 Each air - handling unit over 10,000 cim. $11.00 X 14 Each evaporative cooler other than a portable type. $6.50 X 15 Each ventilation fan connected to a single duct. $4.50 X 16 Each ventilation system which is not a portion of any heating or air - conditioning system authorized by a permit. $6.50 X 17 Installation of each hood which is served by mechanical exhaust, including the ducts for such hood. $6.50 X 18 Installation or relocation of each commercial or industrial -type incinerator. $1'1.00 X 19 Installation or relocation of each commercial or industrial -type incinerator. $45.00 X 20 Each appliance or piece of equipment regulated by the code but not classed in other appliance categories, or for which no other fee is listed in this code. $6.50 X 06/18/g0 SUBTOTAL 00 of PLAN CHECK FEE subtotal) �ubtotN) GRAND TOTAL $ . �-l• O tD CITY OF TUKWILA Department of Community Development - Building Division 6300 Sauthcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 THIS WORKSHEET MUST ACCOMPANY YOUR MECHANICAL PERMIT APPLICATION. MECHANICI L PERMIT FEE WORKSHEET INSTRUCTIO Complete the worksheet, Indicating the number of units being nstalled in each category. 4t time of ubmittal, c alculate the fees. CITY OF TUKWILA 6200 SOUTIICENTKR BOULEVARD, TUKWILA, WASIIINGTON98188 Plan Check #91- 203 -M: Character Corner 864 Southcenter Mall PIIONE # (206) 433.1800 Gary L. VanDusen, Mayor THE FOLLOWING COMMENTS APPLY TO AND BECOME PART OF THE APPROVED PLANS UNDER TUKWILA MECHANICAL PERMIT NUMBER zyUoa -(n . 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (872- 6363). 3. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 4. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 5. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1991 Edition), and Washington State Regulations for Barrier Free Facility (1989 Edition). 6. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 'roect: J � ypeo nspe ress: /4 .i, C7i=' 414e <te (, l Special Instructions: i Date Wanted: Requester: Phone No.: r�;b�.m+1'.C.:... c4....- �;�.r,� !` ?p!pM•yY'rr }•'riu ry"ru lu">ryi^.Ft.�..ww�:,.yr +y w• r..��.F.w �f: INSPECTION RECORD Retain a copy with permit 0. C CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 P RMCT (206) 431 -3E70 4 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: / I Inspector i Date; `/ /9 9/ ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ' ro ect: ype o nspect •n: L'_ La. — .. ........ _ i[.r� • •. re.: - •<te a :.: Special Instrucllons: Date Wanted: /f-/ 3— 9/ am(g? Requester: Phone No.: i•3y= S'' ' ' ' ` NNW ',ti* Tr J ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit. (206) 431 -3670 ❑ Corrections required prior to approval. COMMENTS: boa - e e 0 I Inspector o e: / , 3—e7/ ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: LIIMigra ype o nspe« M Tess• • . ; • Sp: al Instruct ons: t\-)M" 2 P 1A\93 - 4)-e> U`� Date ant: : il _ e ,.... 1 g m Requester: I raNallall /L Phone No.: ,.,. G . / 2 - , 0 . ,h.= �'v rLG IN /w (L, 4 F cal nl' c t 1 o v 7 P■%0 A (4 7 c-q %1M - 1 , A3V ro ect: LIIMigra ype o nspe« M Tess• • . ; Ai ;, Date a = � : Sp: al Instruct ons: Date ant: : il _ e ,.... 1 g m Requester: I raNallall /L Phone No.: ,.,. Inspector: Recept No.: 0. ❑, Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT 7 (206) 431(206) 431 -3670 ❑ Corrections required prior to approval. Date:1 t - ( 2• - 1 ( ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: • BUILDING MASTER DATA AND DESIGN DESIGN OUTDOOR MONTH DRY BULB AUGU$T JUNE JULY SEPTEMBER JANUARY FEBRUARY WINTER ROOF ASHRAE TYPE ROOF # 86 84 S8 8O 54 59 24 68 66 69 65 . 48 50 0 ROOF ROOF SUSP U -FAC COLOR CLG. 1. 11 0.070 LIGHT YES GENERAL PROJECT INFORMATION: BUILDING DEFAULT VALUES: CALCULATIONS PERFORMED: LIGHTING REQUIREMENTS: EQUIPMENT REQUIREMENTS: PEOPLE SENSIBLE LOAD MULTIPLIER: PEOPLE LATENT LOAD MULTIPLIER: PEOPLE OCCUPANCY BASIS: ZONE SENSIBLE SAFETY FACTOR: ZONE LATENT SAFETY FACTOR: ZONE HEATING SAFETY FACTOR: PEOPLE DIVERSITY FACTOR: LIGHTING PROFILE NUMBER: EQUIPMENT PROFILE NUMBER: PEOPLE PROFILE NUMBER: BUILDING DEFAULT CLG. HEIGHT: BUILDING DEFAULT WALL HEIGHT: AIR HANDLER # 1 INPUT DATA: AIR HANDLER DESCRIPTION: TERMINAL TYPE: METHOD FOR CV: SUPPLY FAN TYPE: CALCULATIONS PERFORMED: EXCESS SUPPLY AIR: NUMBER OF TIMES SYSTEM OCCURS: LIGHTING PROFILE NUMBER: EQUIPMENT PROFILE NUMBER: PEOPLE PROFILE NUMBER: EXHAUST CAN EXCEED SUPPLY AIR: LEAVING HEATING COIL TEMP. (DEG.F): DRY BULB TEMPERATURE ( DEG.F): COOLING COIL CFM: MISC. BTUH GAIN - SUPPLY SIDE: MISC. BTUH GAIN - RETURN SIDE: COMBINED FA9,MOTOR EFFICIENCY ( %): STATIC PRESS. ACROSS FAN (IN W.G): SUMMER SUPPLY DUCT TEMP. RISE (DEG.F): SUMMER RETURN DUCT TEMP. RISE (DEG.F): WINTER SUPPLY DUCT TEMP. DROP (DEG.F): WINTER RETURN DUCT TEMP. DROP ( DEG.F): CHILLED WATER TEMP.DIFFERENCE (DEG.F): HOT WATER TEMP.DIFFERENCE (DEG.F): COOLING VENTILATION METHOD: COOLING VENTILATION VALUE: COOLING INFILTRATION METHOD: COOLING INFILTRATION VALUE: HEATING VENTILATION METHOD: HEATING VENTILATION VALUE: HEATING INFILTRATION METHOD: HEATING INFILTRATION VALUE: VENTILATION IS 100% OF SUPPLY AIR: PRETREATED OUTSIDE AIR: IGNORE PRETREATED LOAD: PRETREATED DRY BULB AIR TEMP (DEG.F): PRETREATED WET BULB AIR TEMP ( DEG.F): PARAMETERS: OUTDOOR INDOOR WET BULB REL.HUM 50% 50% 50% 50% 50% 50% 50% PROJECT FILE NAME: PROJECT LOCATION: BAROMETRIC PRESSURE: ALTITUDE: NORTH LATITUDE: MEAN DAILY TEMPERATURE RANGE: STARTING TIME FOR HVAC LOAD CALCULATIONS: ENDING TIME FOR HVAC LOAD CALCULATIONS: FLOOR HEAT LOSS COEFFICIENT: NUMBER OF UNIQUE ZONES IN THIS PROJECT: * * * * * * * * * * * * * * * * * * * * * * * * *,* AIR HANDLER INPUT DATA * * * * * * * * * * * * * * * * * *k * * * * * ** * * * * * * * * * * * * * * * * * * * * * ** AIR•SYSTEM I 1 'LUNE SUMMARY 1 MAIN STORE 9 PM FEBRUARY 1 PLENUM. 9 PM JULY ZONE PEAK TOTALS * * * ** * * * * * * ** * * * * ** LOAD DESCRIPTION 1. MAIN STORE CLG.PLENUM LIGHTS -0 EQUIPMENT -0 PEOPLE -0 TOTAL 2. PLENUM SYS# 1 ROOF 1 11- SUSP.0 -L PLNM.CREDIT LIGHTS -0 TOTAL INDOOR GRAINS DRY BULB DIFF. 78 2.59 78 -4.57 78 4.70 78 -3.08 78 -32.42 78 -33.28 70 0.00 DETAILED PROJECT ZONE LOAD CALCULATIONS UNIT -SC- CLTD U.FAC SEN. QUAN CFAC SHGF -CLF- GAIN MM. IND SYS# 1 PEAK TIME 9 PM FEB. 500 5/10 0.310 3250.00 1.000 90% 3.410 250.00 1.000 3.410 15.15 1.000 255/255 PEAK TIME 9 PM JUL. 50O 0.500 23 0.070 500 -5/ -10 0.310 3250.00 1.000 10% 3.410 B:SOUTHCTR SOUTHCENTER 29.491 IN.HG. 400 FEET 47 DEGREES 26 DEG.F 9 AM 9 PM 0 BTUH PER FOOT OF SLAB 1 BOTH HEATING AND COOLING LOADS 6.50 WATTS PER SQUARE FOOT 0.50 WATTS PER SQUARE FOOT 255 BTU PER PERSON 255 BTU PER PERSON 1 PERSON PER 33 SQ.FT 10% 10% 20% 100% 0 0 0 10.0 FEET 10.0 FEET DX -GAS PACKAGED UNIT CONSTANT VOLUME SUM PEAK ZONE CFMS BUILT -IN PACKAGED UNIT BOTH HEATING AND COOLING LOADS RESERVE CAPACITY 1 0 0 0 YES 100 58 0 0 0 0 • 0.000 1.000 0.000 1.000 0.000 0.000 0.000 3 0.300 CFM PER SQ.FT 0 0.000 3 0.300 CFM PER SQ.FT 0 0.000 NO NO NO 0 0 ZN. ZONE - DESCRIPTION FLOOR HTG.LOSS SEN.GAIN LAT.GAIN HTG.CFM CLG.CFM NO. PEAK TIME & MONTH AREA 0.A. CFM O.A. CFM EXH. CFM CFM /SF. CFM /SF. 500 1,860 17,013 4,250 144 826 150 150 0 0.29 1.65 0 72 617 0 0 0 0 0 0 0.00 0.00 500 1,932 17,630 4,250 14: 826 150 150 0 0.29 1.65 775 9974 853 3864 3864 15,466 3,864 X 1.10 X 1.10 17,013 4,250 228 -775 1108 561 0 X 1.10 X 1.10 XXWXXNnxxnarasflaaAaaaa,,, * * * * * * * * * * * * * * * * - -. IN /OUTDOOR CORRECTION LAT. HTG. HTG. GAIN MULT. LOSS (50 X 10) = 500 SF (0 X 0) 3.220 -3.100 1,550 X 1.20 1,860 = 0 SF 1610 -1550 60 x 1.20 72 - 12 - 14 - 10 -18 - 44 -39 ******************** AIR SYSTEM # 1 TOTAL LOAD SUMMARY * * * * * * * * * * * * * * * * * * * ** AIR HANDLER DESC: DX -GAS PACKAGED UNIT WITH CV (SUM OF PEAKS) TERMINALS SENSIBLE HEAT RATIO: 0.81 THIS SYSTEM OCCURS 1 TIME(S) IN THE BUILDING AIR SYSTEM PEAK TIME: 5 PM IN JULY OUTDOOR CONDITIONS: 35 DB, 69 WB, 83.40 GRAINS BECAUSE OF THE DIVERSITY IN ZONE, PLENUM, AND VENT. PEAK TIME IN FEBRUARY AT 9 PM IS DIFFERENT FROM HENCE, THE AIR SYSTEM CFM WAS COMPUTED USING A ZONE SUMMER: VENT CONTROLS OUTSIDE AIR WINTER: ZONE SPACE INFILTRATION OUTSIDE AIR SUPPLY DUCT RETURN DUCT SEN.LOSS: SEN.LOSS: SEN.LOSS: SEN.LOSS: SEN.LOSS: TOTAL SYSTEM SEN.LOSS: SUPPLY AIR: 2,092 / (0.986 X 1.08 X 13.0997 WINTER VENT OUTSIDE AIR (100% OF SUPPLY): ZONE SPACE SEN.GAIN: INFILTRATION SEN.GAIN: DRAW -THRU FAN SEN.GAIN: SUPPLY DUCT SEN.GAIN: TOTAL SEN.GAIN ON SUPPLY SIDE OF COIL: SUPPLY AIR: 17,908 / (0.986 X 1.1 X 20) SUMMER VENT OUTSIDE AIR (18.16% OF SUPPLY): RETURN DUCT SEN.GAIN: RETURN PLENUM SEN.GAIN: OUTSIDE AIR SEN.GAIN: BLOW -THRU FAN SEN.GAIN: TOTAL SEN.GAIN ON RETURN SIDE OF COIL: TOTAL SEN.GAIN ON AIR HANDLING SYSTEM: ZONE SPACE INFILTRATION OUTSIDE AIR LAT.GAIN: LAT.GAIN: LAT.GAIN: TOTAL LAT.GAIN ON AIR HANDLING SYSTEM: TOTAL SYSTEM SENSIBLE AND LATENT GAIN: TOTAL TONNAGE REQUIRED WITH OUTSIDE AIR: SECTION 15010, GENERAL PROVISIONS 1.01 GENERAL: CONFORM TO ALL GENERAL CONDITIONS. THIS SECTION OF THE SPECIFICATION APPLIES TO THE ENTIRE MECHANICAL WORK, AS SPECIFIED AND SHOWN ON THE PLANS. 1.02 SCOPE: PROVIDE ALL SERVICES AND MAKE FINAL CONNECTIONS TO EXISTING, AS SHOWN ON PLANS. 1.03 INTENT OF DRAWINGS: DRAWINGS SHOW ONLY APPROXIMATE LOCATION OF PIPING, FIXTURES, EQUIPMENT AND THE GENERAL REQUIREMENTS AS TO SIZE AND LOCATION OF PIPES, ETC. TAKE MEASUREMENTS FROM THE BUILDINGS AND CHECK AGAINST THE MECHANICAL PLANS. REPORT CONFLICTS TO ARCHITECT FOR ADJUSTMENT BEFORE PROCEEDING WITH WORK. 1.04 CODES: CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF UNIFORM BUILDING CODE, MECHANICAL, PLUMBING, ELECTRICAL, NBFU AND NFPA CODES AND LOCAL AMENDMENTS. 1.05 PERMITS AND FEES: OBTAIN AND PAY FOR ALL PERMITS AND CONSTRUCTION FEES. 1.06 EUBMITTED DATA: SUBMIT COMPLETE BOUND BROCHURES GIVING NAMES OF TECHNICAL DATA FOR EACH ITEM OF EQUIPMENT. SUBMIT SIX (6) COPIES EACH WITHIN 15 DAYS AFTER AWARD OF CONTRACT. 1.07 COORDINATION: EXAMINE THE ARCHITECTURAL, STRUCTURAL AND ELECTRICAL DRAWINGS; BEFORE WORK IS STARTED, CONSULT WITH EACH OF THE OTHER CONTRACTORS REGARDING LOCATIONS AND SPACES REQUIRED FOR THE WORK AND LAY -OUT WORK TO AVOID INTERFERENCES. AS- BUILT: KEEP A SET PENCIL AS THEY OCCUR. OF PROJECT. OPERATING INSTRUCTIONS OF DESIGNATED OWNER'S 1,932 BTUH O BTUH ( 7,345 BTUH ( 164 BTUH O BTUH 17,013 BTUH O BTUH 0 BTUH 895 BTUH 0 BTUH 540 BTUH 1,138 BTUH 0 BTUH 4,250 BTUH 0 BTUH ( 968 BTUH ( VENT CONTROLS OUTSIDE AIR 0 CFM) 150 CFM) 150 CFM) 150 CFM) 0 CFM) 826 CFM) 150 CFM) 150 CFM) 0 CFM) 150 CFM) INSIDE: 78 DB, 50% RH LOADS, THE ZONE SENSIBLE THE TOTAL SYS. PEEK TIME SEN. LOAD OF 17,013 5,218 BTUH 24,804 BTUH 2.07 TONS 3.100 1550 • 1.08 CUTTING AND PATCHING: ALL NECESSARY CUTTING AND PATCHING OF EXISTING STRUCTURES NECESSARY FOR THE INSTALLATION OF MECHANICAL WORK SHALL BE DONE BY THE 0 GENERAL CONTRACTOR. 1.09 ACCESSIBILITY: LOCATE VOLUME DAMPER, DAMPER OPERATORS, TILTER, ETC., WITH EASY ACCESSIBILITY. 1.10 MECHANICAL ACCESSES: PROVIDE SUITABLE ACCESS TO ALL MECHANICAL EQUIPMENT REQUIRING SERVICING, MAINTENANCE, REPLACEMENT OR REPAIR. 1.11 MATERIAL AND MATERIAL SUBMITTALS: ALL MATERIAL USED ON THE PROJECT SHALL BE NEW DOMESTIC MATERIAL FREE FROM DEFECTS. 1: 1.12 TESTS, ADJUSTMENTS AND INSPECTION: TEST ALL WORK THOROUGHLY AND SYSTEMATICALLY, BOTH DURING CONSTRUCTION AND AFTER COMPLETION. 1.13 AS- BUILTS, OPERATING INSTRUCTIONS, MAINTENANCE AND OPERATION MANUALS: MAINTENANCE AND OPERATIONS MANUALS: PROVIDE FIVE (5) BOUND SETS OF OPERATION AND MAINTENANCE MANUALS INCLUDING MAINTENANCE INFORMATION AND PARTS LIST FURNISHED BY THE MANUFACTURER WITH THE EQUIPMENT, TOGETHER WITH SUPPLEMENTARY DRAWINGS WHERE NECESSARY TO ITEMIZE SERVING AND MAINTENANCE POINTS. OF DRAWINGS ON SITE, WITH CURRENT `CHANGES MARKED IN RED THIS SET SHALL BE PRESENTED TO ARCHITECT UPON COMPLETION : OPERATE ALL SYSTEMS THROUGH COMPLETE CYCLES IN PRESENCE REPRESENTATIVE. 1 1 1 i I1 1 I 1 1` 2 I 3 4i 6� 6) ' No.18 IIii�IIII I!II�IIII 9,437 BTUH 17,908 BTUH 1,678 BTUH 19,586 BTUH ' 2 E1 Z C R1I 325 GEN w - -> 1 5OUNI2l.I N i N4 1.14 DOCUMENTS: PRESENT TO THE ARCHITECT PRIOR TO FINAL ACCEPTANCE OF BUILDINGS THE FOLLOWING DOCUMENTS. FINAL PAYMENT OF THE CONTRACT WILL BE CONTINGENT UPON RECEIVING THESE DOCUMENTS: AS -BUILT DRAWINGS. MAINTENANCE AND OPERATING INSTRUCTIONS. FINAL MATERIAL SUBMITTAL. WARRANTIES (OTHER THAN THE ONE YEAR). BALANCING LOGS. FINAL CERTIFICATES OF INSPECTION AND CODE COMPLIANCE. 2.01 VIBRATION MOTORIZED EQUIPMENT SHALL BE MOUNTED ON OR SUSPENDED FROM SPRING VIBRATION ISOLATORS MASON TYPE `HS'. SECTION 15600, FIRE SPRINKLING 1.01 GENERAL: MODIFY AND EXTEND FIRE SPRINKLING SYSTEM TO COMPLY WITH NFPA 13 LOCAL CODES, AND LANDLORD REQUIREMENTS. PROVIDE AND INSTALL THROUGHOUT FACILIT WITH QUICK RESPONSE SPRINKLER HEADS. 2.01 SPRINKLER HE)QS: VIKING, OR APPROVED EQUAL, RECESSED IN CEILING, CHROME - PLATED ESCUTCHEON TYPE WITH MODEL "M" CHROME HEAD AND HEAT - SENSITIVE GLASS BULB. SECTION 15800, AIR DISTRIBUTION SYSTEM 1.01 GENERAL: CONFORM TO ALL GENERAL CONDITIONS. 1.02 SHEET METAL DUCTWORK: DUCTS SHALL BE OF GALVANIZED STEEL. ALL JOINTS AND SEAMS SHALL BE TAPED WITH 3 -M VINYL IMPREGNATED CLOTH TAPE, OR ATLAS MP SEALANT. DUCTS SHALL BE INSTALLED PER NFPA PAMPHLET 90A. GAUGES SHALL BE IN ACCORDANCE WITH ALL DATA SHOWN IN "ASHRAE GUIDE AND DATA BOOK, EQUIPMENT ". 2.01 FLEXIBLE DUCT: MAXIMUM LENGTH OF FLEXIBLE DUCT, 4 -FEET. THERMAFLEX G -KM, NOR -FLEX NT -25, OR APPROVED EQUAL. 2.02 DUCT INSULATION: INSULATION SHALL BE PROVIDED FOR ALL SUPPLY AIR DUCTWORK. ALL INSULATION SHALL HAVE COMPOSITE (INSULATION, JACKET, OR FACING AND ADHESIVE USED TO SECURE FACING OR JACKET TO INSULATION) FIRE AND SMOKE HAZARD RATINGS AS TESTED BY PROCEDURE ASTM E -84, NFPA 255 AND UL 723, NOT EXCEEDING: FLAME SPREAD 25 SMOKE DEVELOPED 50 SUPPLY -AIR DUCTWORK_(RECTANGULAR DUCT): PROVIDE FIBERGLASS COATED DUCT LINER 1" THICK (1 -1/2 LBS. /CU.FT. DENSITY) FOR ALL DUCTWORK. SIZES: ALL DUCT SIZES SHOWN ON PLANS ARE NET SIZES AFTER INSULATION IS IN PLACE. 2.03 AIR TERMINALS (LOW VELOCITY): PROVIDE THE VARIOUS GRILLES, REGISTERS AND DIFFUSERS SHOWN ON THE PLANS AND OF THE TYPES HEREINAFTER SPECIFIED. ALL TERMINALS WITH PRIME -COAT FINISH SHALL BE IN,iTALLED BEFORE THE WALLS AND CEILINGS ARE PAINTED IN ORDER THAT THEY MAY BE FINISH - COATED BY THE GENERAL CONTRACTOR. THOSE WITH FACTORY FINISH OR ALUMINUM CONSTRUCTION SHALL BE INSTALLED AFTER THE WALLS AND CEILINGS ARE PAINTED. CEILING DIFFUSERS SHALL HAVE FACTORY - APPLIED BAKED ENAMEL FINISH, COLOR S SELECTED BY ARCHITECT. THE INTERIOR OF DUCT CONNECTION INCLUDING OPPOSED 'BLADE DAMPER AND ALL VISIBLE DUCT INTERIORS AT CONNECTION SHALL BE PAINTED MATTE BLACK. EACH AIR TERMINAL SHALL BE INSTALLED WITH A SPUN - RUBBER GASKET BETWEEN THE FLANGE AND THE FRAME OR WALL. 2.04 TERMINALS CEILING DIFFUSER (CD- 1,2,3,4): TITUS DIFFUSER MODEL TDCA FOR INSTALLATION IN T -BAR CEILINGS. PROVIDE 24" X 24" PANS WHERE REQUIRED AND FURNISH DIFFUSER WITH VOLUME DAMPER. CEILING RETURN GRILLE (CRG): TITUS MODEL 50 -F GRILLE FOR T -BAR MOUNTING. PAINT DUCT MATTE BLACK BEHIND GRILLE. PROVIDE WITH OPPOSED- BLADE DAMPER, AND 24" X 24" PAN WHERE REQUIRED. SECTION 15810 - AIR HANDLING EQUIPMENT /DIRECT EXPANSION COOLING SYSTEM 1.01 GENERAL: CONFORM TO ALL GENERAL CONDITIONS. 1.02 SYSTEM DESCRIPTION: SPLIT SYSTEM AIR CONDITIONING UNIT IS INTEGRATED WITH AIR TERMINALS, DUCTWORK, AND CONTROLS TO PROVIDE HEATING AND CONDITIONED AIR TO ALL SPACES AS SHOWN ON PLANS. 1.03 WARRANTY: THE ENTIRE HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS, INCLUDING CONTROLS AND ALL PARTS THEREOF, SHALL BE WARRANTED FOR A PERIOD OF ONE YEAR AFTER THE DATE: OF FINAL ACCEPTANCE. ADDITIVE /DEDUCTIVE ALTERNATE NO. 1 BIDDER DESIGN HVAC SYSTEM: G 9 5 I; E Z W3T IIII�IIII IIIIIIIIIIIIII�IIII IIIIIIIII (III�IIII IIII�IIII i iiiliiii II 1111111 Illiliiii IIII�IIII IiIIIIIII IIII�IIII lIIIIIII 9x 2.00 cFM A. ENGINEER COMPLETE SYSTEM BASED ON THE FOLLOWING CRITERIA: 1. RECONDITION AND REUSE EXISTING SPLIT SYSTEM COMPONENTS. 2. MODIFY EXISTING COMPONENTS FOR ACTUAL DESIGN REQUIREMENTS OF SPACE: ROOF TOP UNIT: REDUCE COMPRESSOR CAPACITY. INSIDE UNIT: REDUCE CFM CAPACITY AND OR SPLIT OFF EXCESS SUPPLY DIRECTORY TO RETURN AIR PLENUM. 3. PROVIDE NEW REFRIGERANT, PIPING AND POWER TO BOTH UNITS. 4. MINIMIZE NUMBER OF CEILING DIFFUSERS /GRILLES. MAX CFM PER DIFUSSER: 300. B. PROVIDE COMPLETE SYSTEM. C. SUBMIT SHOP DRAWINGS TO ARCHITECT FOR ARCHITECT /LANDLORD REVIEW WITHIN FIVE DAYS OF BID AWARD. - Y 12 10 1.04 STARTERS: SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED OR SHOWN. 2.01 INDOOR UNIT A,V: SHALL BE TRANE MODEL TWH730B140A AIR HANDLER WITH 3.6 KW SUPPLEMENTARY HEATER RATED AT 208V, 10. SUPPLY FAN: 850 CFM AT 0.5" S.P., 'h HP, 208 -VOLT, 10. OUTDOOR UNIT AC -]: SHALL BE TRANE MODEL TTR724B100A WITH A CAPACITY OF 24,200 BTUH TOTAL COOLING AND 18,300 BTUH SENSIBLE COOLING. 2.02 THERMOSTAT: PROGRAMMABLE ELECTRONIC NIGHT SETBACK THERMOSTAT TO PROVIDE HEATING SETBACK AND COOLING SETBACK WITH 7 -DAY PROGRAMMING CAPABILITY. SINGLE -STAGE HEATING AND COOLING. PROVIDE LOCKABLE COVER. 2.03 PROVIDE INDOOR UNIT AND OUTDOOR UNIT WITH SINGLE POINT CONNECTION. 2.04 REFRIGERANT PIPING: RUN ALL LIQUID AND SUCTION LINES FROM OUTDOOR UNITS TO INDOOR UNITS AS INDICATED ON THE DRAWINGS IN TYPE "L" "WASHED AND CAPPED ", ANACONDA ACR, OR EQUAL, COPPER. PROVIDE COPPER TUBE OIL TRAPS AT BOTTOM OF EACH 15' OF VERTICAL RISER AND AS DIRECTED BY EQUIPMENT MANUFACTURER. ALL SOLDERING OR BRAZING SHALL BE DONE WITH SILVER ALLOY -TYPE MATERIAL "SIL -FOS ", OR APPROVED EQUAL, WITH CONTROLLED FLOW' OF NITROGEN GAS FED THROUGH TUBING TO PREVENT OXIDIZING OF INTERIOR LINES. ALL REFRIGERANT LINES SHALL BE SPRING ISOLATED FROM THE BUILDING STRUCTURE. AT WALL PENETRATIONS, CAULK BETWEEN THE METAL CASING AND THE STRUCTURE WITH )`ION - HARDENING PLASTIC CAULKING COMPOUND SIMILAR TO AMERICAN MARIETTA PESTITE, GUM GRADE, NON - SKIMMING COMPOUND. PROVIDE ROOF JACKS AT ROOF PENETRATIONS, INSTALLED TO PROVIDE WEATHERTIGHT SEAL WITH ROOF. 2.05 CONDENSATE DRAIN: CONDENSATE DRAIN PIPE SHALL BE SCHEDULE 40, TYPE "I" PVC 1,220 (ASTM D1785 -67A). FITTINGS SHALL BE TYPE "I ", SCHEDULE 40 PVC (ASTM 02466- 67). 2.06 REFRIGERANT PIPING INSULATION: THE ENTIRE LENGTH OF THE HOT GAS AND SUCTION LINES SHALL BE INSULATED WITH ARMSTRONG, OR EQUAL, 3/4" ARMAFLEX II INSULATION. LIQUID LINES SHALL NOT BE INSULATED. DO NOT STRAP LIQUID LINES TO ANY OTHER PIPING OR STRUCTURE. THIS INSULATION SHALL BE INSTALLED AS SYSTEM IS PIPED AND SHALL NOT BE SPLIT. ALL JOINTS SHALL BE SEALED WITH ARMSTRONG 520 ADHESIVE. COVER ALL INSULATED PIPING EXPOSED TO WEATHER WITH ALUMINUM JACKET WITH VAPOR BARRIER AS MADE BY CHILDERS OR PABCO. 2.05 FILTERS: PROVIDE 2" THICK FARR 30/30, OR EQUAL. 3.01 GENERAL: INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. 3.02 WARRANTY: ENTIRE SYSTEM SHALL HAVE A ONE -YEAR WARRANTY FROM DAY OF BUILDING ACCEPTANCE. SECTION 15860, TESTS AND ADJUSTMENTS 1.01 GENERAL REQUIREMENTS: CONFORM TO ALL OF THE GENERAL CONDITIONS. 1.02 THE MECHANICAL CONTRACTOR SHALL INCLUDE IN HIS BID AN ADEQUATE SUM TO COVER ALL COSTS OF TESTS AND ADJUSTMENTS. TESTING, ADJUSTMENTS AND BALANCING SHALL BE PERFORMED IN ACCORDANCE WITH NEBB STANDARDS AND PROCEDURES. 3.01 GENERAL: AIR BALANCE AND TESTING SHALL NOT BEGIN UNTIL THE SYSTEM HAS BEEN COMPLETED AND IS IN FULL WORKING ORDER. 3.02 LOGS AND REPORTS GENERAL: THE TESTS AND ADJUSTMENT FIRM SHALL SUBMIT LOGS AND REPORTS AS PER THE FOLLOWING: AIR BALANCE LOG: ADJUST AND RECORD SYSTEM FOR DESIGN RECIRCULATED AIR, CFM. ADJUST ALL SUPPLY RETURN AND EXHAUST AIR DUCTS TO PROPER DESIGN CFM. TOTAL AIR QUANTITIES SHALL BE ADJUSTED BY VOLUME OR SPLITTER DAMPERS. TEST AND ADJUST ENTIRE SYSTEM TO WITHIN PLUS OR MINUS 10% OF DESIGN REQUIREMENTS. EACH GRILLE, DIFFUSER AND REGISTER SHALL BE IDENTIFIED ON TEST REPORT AS TO LOCATION AND AREA. IDENTIFY AND LIST SIZE, TYPE, AND MANUFACTURER OF DIFFUSERS, GRILLES, REGISTERS, AND ALL TESTED EQUIPMENT. MANUFACTURER'S RATINGS AND COEFFICIENTS USED. VOi -uM1✓ t2J11`1 rt.de (TYr) - ?Al cp'2 ZOO G M Yo 11 0" A COU_AR TO CONNECT TO DIFFUSER NECK t ._ . C GvNINsc> •GAIN i2N ' 91261 Ni C-- 14/10 W - . CaUN G DIFFUSER PER PLANS 2vx2.0x24 12s �Z2 .� -E- FLE (I61 ' DUCT, SIZE PER PLANS CEILING DIFFUSER DETAIL NO SCALE I under and that ti' a Plan Check approvals are sub)ogt to errors and omissions and approval of plans dDef not authorize the violation of any a dupisd code or ordinance. Receipt of con - frp(;t9r" - • ed I C • owledged. T=ILE COPY V Sy Dote ,_....L Permit No. - i- -x GONW' lON RECEIVE CIV OF TI IICNILP "1 I l 41 *WW PERM►? CENTER THESE OP.AWINOS ARE INSTRUMENTS OF SERVICE AND ARE AND SMALL REMAIN THE PROPERTY OF THE ARCHITECT WHETHER THE PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. THEY ARE NOT TO SE USED Sr THE OWNER OR AkY OTHER PERSON ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT SY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO THE ARCHITECT DRAWN OFFICE APPROVAL OWNER APPROVAL .rpg.- r IT Character Corner Southcenter Mall Ste.526 Tukwila, Washington HAMILTON ARCHITECTS, P.S. 904 Alaskan Way SeaNte. WA 98104 206 623.5677 111 enaT M •1