Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit 0624-M - SYSTEM SEVEN
i 33TEM s■ • PROPERTY OWNER: liMC F,DITION (YEAR : 1988 Detectors x N/A SUITE NO. FIRE PROTECTION: Serinklers (other than noted on or attached to permit/plans): _CONDITIONS S Other: 1 . A APPROVED FOR ISSUANCE BY: it , NW BUILDING s P mum OFFICIAL DATE: /1 ( 9/ pi I hereby certify that I have read and examined this permit and know the same of law and ordinances governing this work will be complied with, whether specified this permit does not presume to give authority to violate or cancel the provisions regulating construction or the performance of work. I am authorized to sign 16904 N.E. 104th Ct, Redmond, WA to be true and correct. All provisions herein or not. The granting of of any other state or local laws for and obtain this mechanical permit. SIGNATURE: 98052 WA. ST. CONTRACTOR'S DATE: / / - 6 — , / COMPANY: 42-er'edn../5 F-e-ek/vile.6,--11)0RK C...6--e-<-0._ PRINT NAME: Sc_ert Xi PleRee- PROPERTY OWNER: AB Speed SITE ADDRESS: 10835 Pacific Hy S SUITE NO. PROJE A ,E ENAk S stem Seven VALUE OF WORK: $ 18,766.00 TYPE OF W•R Q New/Addition S Modifications • Re air S Other: DESCRIPTION OF WORK. Install two waste oil furnaces. 98168 CONTRACTOR: Aaron's Furnace Works PROPERTY OWNER: AB Speed PHONE: ADDRESS: 10835 Pacific Highway South, Seattle WA PHONE: ZIP: 861-8795 98168 CONTRACTOR: Aaron's Furnace Works ADDRESS: 16904 N.E. 104th Ct, Redmond, WA ZIP: 98052 WA. ST. CONTRACTOR'S LIQ_ENSE NO, AARONFW099JN (EXPIRATION DATE: 4-15-92 CITY OF TUKWILA Department of Community Development - Building 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431-3670 MECHANICAL PERMIT NO. DL0Q DATE ISSUED: H-qi MECHAWCAL PERMIT (POST WITH PLANS IN A CONSPICUOUS LOCATION) Division AMOUNT . RECEIPT# DATE NUM: 11111 Basic Permit Fee . 15.00 • Unit Fee 20.00 L Plan Check No.: 91-198-m DATE DATE(S) PHONE NO. APPROVED INSPECTOR CORRECTION NOTICE ISSUED REQUIRED INSPECTIONS 1 - Rough-in/Vents/Ducts 2 - Fire Final 3 - Planning Final 4 - 5 - Mechanical Final 431-3670 575-4407 431-3680 431-3670 OTHER AGENCIES: Plumbing/Gas Piping - King County Health Department (296 Electrical - Washington State Department of Labor and Industries (277-7272) This p ermit fitll become null and void if . the w�rk is not commenced within 180 days fron1.1. d ate of issuance, or if the work is suspended or abandoned for a period Of 180 days from e.last.ipspeps PERMIT NO. CONTACTED L- 1111, i 6 ` e _ DATE READY DATE NOTIFIED i B 7 ��r IM PERMIT EXPIRES 2nd NOTIFICATION BY: init. AMOUNT OWING • 3 .15 3RD NOTIFICATION BY: init MECHANIC k. PERMIT APPLICATION TRACKING PLAN CHECK NUMBER BUILDING - initial review REVIEW COMPLETED ( -/P - Te-TY) SITE ADDRESS ra c PROJECT NAME INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. O FIRE PLANNING O OTHER BUILDING - final rRviaw R'�QUIRENIENT ...1..... ZONING: BAR/LAND USE CONDITIONS? Yes UMC EDITION (year): INIT: 4( UTEDI INIT: REFERENCE FILE NOS.: SUI E NO. CONSULTANT: Date Sent - Date Approved FIRE PROTECTION: ( ) Sprinklers Detectors O N/A FIRE DEPT. LETTER DATED: INSPECTOR: DESCRIPTION' . . I.:. AMOUNT IRCPT V. . DATE SAS O..,PERMIT • Li ..,.,.......::::. ::... ..:::.......::y...:•: UNITS EE • ; •i• • • Noss•.: ,.. .1 • •i•': :,.... :'• .•••••' . i ,.., ::. , ..::::."i4.:.: PLAN`.:CHEOK•' • •••• - ., , 7 9 Eft .',!;.:?,:::y........!.:!: : :;:: . -•.:,.....:-..,:::.!..,,-.:. .: :.,•-• .‘::.'? T •-• 11 - [f77 & SUIT-. # I r, • , Jr V 10105 P , VALUE OF ;ONSTRUCTION, $ 4 ;r 4 3 ./ NAy &TENANT Ceo e it) ef 4-ir - I 0 Other: TY0E4F . New/Addition 0 Modifications 0 Repair ,._....., DESCRIBE 'NOR • • E DONE: 57 U---- 2- Lo 65 '7 .:) /e... /z- K. /v a S , Ori e 5 im-e cBE Typb. ... : .:. ::. .. : .: :, : RATRbisizE.: . ' . RIMER OF UNITS (4) G? 7 - (::, L -414ien4cel - Zoo 00 57 /c e, ct f pu7— dp_FA . th7 �Jt- 0/4 I — ----- BUIL*ING USE office, warehouse, etc.) ‘ _.S.. NATURE OF BUSIN I tuci_ ke_PK-IY — WILL i t HERE BE A CHANGE IN USE7XNd 7IYes IF YE:S, EXPLAIN: I i WILL "THERE BE STO. 'E OS USE OF FLAMMABLE, COMBUSTIBLE EWING? •._. No Yes IF YES, EXPLAIN: 0 • ° 4•0 N- F OR HA2ARDOUS . - ' MATERIALS IN THE — . ____jyj±25. / • ., :- tiONCONIINAP PRORERTY OWNER • tia s-p.e.e.. • PHON7 ADDIIIESS _,___td 3 p ,...,,,,_ , = ------------ I zip 9r/4 f coNTR ACTOR /.4. ADDITIESS 26 (,•). Hj6 -- Lc) 1 , e ) ,A c::: 2___ g 4 , 1 0 0 --e I Z EXP. DATE WA. T CUNT LICENSE # X2- v CITY OF TUKWILA Department of Community Development - Building Division 8300iSouthoenter Boulevard, Tukwila WA 98188 (206) 431-3670 PL1 CHECK NI MEIER Ld 9 )1f APPLICATION MUST BE FILLED OUT COMPLETELY RE MECHAr7AL PERMIT APPLICATION Al anIcal Foe Worksheet must also be fliltycf out MCNoonstalre FEES (for staff use only) 71 r EBY 'CERTIFY THAT . I HAVE READ AND ExAmmeD. APPLICATION KR 'TO OW L:SAME TO BE TililiE•AND AND...I AM .AU.THORIZ.EI>TO:.APPLY FOR THIS:.PERMM r - :••• • .. • .• • • .• B',JII OWNER L i OR I AUTHORIZE ?Rl NAME s / t e_7/ 72e AGENT LONTACT PERSON 'ADDRESS /(42_2(i 4-1 DATE I — PHONE CITY/ZIP c 7e12.2 'PHONE OM. 0 0.••■••,•■■■••■■•■•• APPLICATJON SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill • out the application completely and follow the plan submittal checklist on the reverse side of this corm. A completed "Mechanical Permit Fee Worksheet" must accompany this permit application. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements, Application and plans must be complete in order to be accepted for Plan review. BUILEIGING OWNER I AUTHORIZED AGENT If the applicant is other than the owr.er, registered architectiengineel, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent • to submit this permit application and obtain the permit will be required as part of this submittal VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled In by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit Is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform ,..hartical Code (current edition). No application shall be extended more than once. If you have a questions about our or plan submittal requirements, please conta. • the Department of C. Development at 431-3670. DATf. APPLICATION ACCEPTED t IT: APPLICATION EXPIRE NU 1 I DESCRIPTION UNIT COST NO OF UNITS X TOTAL COST BASIC FEE $15.00 $4.50 SUPPLEMENT PERMIT FEE 1 Installation or relocation of each forced -air gravity -type furnace or burner, including ducts and vents attached to such appliance, up to and Including 100,000 Btu /h. $9.00 x 2 Installation or relocation of each forced -air or gravity -type furnace or burner, including ducts and vents attached to such appliance over 100,000 Btu /h. $11.00 ( x r �� /° 3 Installation or relocation of each floor furnace, Including vent. $9.00 X 4 Installation or relocation of each suspended heater, recessed wall heater or floor- mounted unit heater. $9.00 X q e4) 5 Installation, relocation or replacement of each appliance vent installed and not included in an appliance permit. $4.50 x 6 Repair of, alteration of, or addition to each heating appliance, refrigeration unit, cooling unit, absorption unit, or each heating, cooling, absorption, or evaporative cooling system, including Installation of controls regulated by this code. $9.00 X 7 Installation or relocation of each boiler or compressor to and including three horsepower, or each absorption system to and including 100,000 Btu /h. $9,00 X 8 Installation or relocation of each boiler or compressor over three horsepower to and Including 15 horsepower, or each absorption system over 100,000 Btu /h and including 500,000 Btu /h. $16.50 x 9 Installation or relocation of each boiler or compressor over 15 horsepower to and including 30 horsepower, or each absorption system over 500,000 Btu /h to and including 1,750,000 Btu /h. $22.50 X 10 Installation or relocation of each boiler or compressor over 30 horsepower to and including 50 horsepower, or for each absorption system over 1,000,000 Btu /h to and including 1,750,000 Btu /h. $33.50 x 11 Installation or relocation of each boiler or refrigeration compressor over 50 horsepower, or each absorption system over 1,750,000 Btu /h. $5fi.00 X 12 Each air - handling unit to and including 10,000 cubic feet per minute, including ducts attached thereto. (NOTE: This fee shall not apply to an air - handling unit which is a portion of a factory- assembled appliance, cooling unit, evaporative cooler or absorption unit for which a permit Is required elsewhere in this code.) $6.50 X 13 Each air - handling unit over 10,000 cfm. $11.00 X 14 Each evaporative cooler other than a portable type. '. $6.50 X 15 Each ventilation fan connected to a single duct. $4.50 X 16 Each ventilation system which is not a portion of any heating or air - conditioning system authorized by a permit. $6.50 X 17 Installation of each hood which Is served by mechanical exhaust, including the ducts for such hood. $6.50 x 18 Installation or relocation of each commercial or industrial -type incinerator. $11.00 x 19 Installation or relocation of each commercial or industrial -type incinerator. $45.00 x 20 I Each appliance or piece of equipment regulated by the code but not classed in other appliance categories, or for which no other fee is listed in this code. $6.50 x 08/1 8/90 SUBTOTAL 35. 00 PLAN CHECK FEE subtotal) •S'15 GRAND TOTAL $' j- � .15 _t CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 THIS WORKSHEET MUST ACCOMPANY YOUR MECHANICAL PERMIT APPLICATION. MECHAN :AL PERMIT FEE WORKSHEET 1111 - Compl to the work sheet, • indicating the number of units being installed in each catego la .At time of. submittal, :staff will calcut the fees. CITY OF TUKWILA 6200 SOUTIICENTER BOULEVARD, TUKWILA, WASHINGTON 98188 Plan Check #91- 198 -M: System Seven 10835 Pacific Hy S P//ONE H (206) 433.1800 Gary L, VanDnsen, Mayor THE FOLLOWING COMMENTS APPLY TO AND BECOME PAR' � OFF,THE APPROVED PLANS UNDER TUKWILA MECHANICAL PERMIT NUMBER WW `L . 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Di vision. 2. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (277- 7272). ' 3. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 4. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 5. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1991 Edition), and Washington State Regulations for Barrier Free Facility (1989 Edition). 6. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. Project: ,5 e/�rn s. 7 Type of Inspection hiieht apt t Address: tA (/oh6► W �, 1(,_ f W1 , Date Called: f ( — 1 f al 1 I Special Instructions: Date Wanted: 11 - fi ' G ) + p,m. Requester: Phone No.: 0 ( f ., $ el INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 D(o24- — (206) 431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. ; ; : L ;7 - , e : /�/ ❑ $30.1 REINFECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. inspector: Recept No,: • Date: u�' fik767-/ � ^//��� N�2�-� - ���[����� �i �,��`�� J �� �� ��rT�v Pt) my '' '` -^' ^ ~ � ^/ � ��� '' r - 4- .L� • � x� �- � . � ��� �� , , �"� . , � �� �' �»*�� ^ w�� " ��^v '�= w " ~�- ' ' �^~~ r "- 4if �~ ' - ' - - ' ^' - �� - ' NOV %� �»w w ��" � ^ � -----_-_-----___-_---_---__'____-'_--' . ..... -_-___ . .... ... ____ ---_-~____ � . -.~_~ ° | ' � -. --__ _~- -'��'���� �«f����' ' .-'--_�_' - -- �� _ ' • ___' / • • — / ' --_-____--_---'-_ - ^_-' , --_____-__�____ ______. (x_441- � �� ^ __�_ ' �� , _---_---_-_'__'.'_- _ , � � _---__'_'_---___- -_~— ' _-_. " '----------'- - " -_-._ _� -�'- ---__.--___-----'__ _ __-- ` ` ~,� �- 1 .. q , 1) . 1 5i el . fik767-/ � ^//��� N�2�-� - ���[����� �i �,��`�� J �� �� ��rT�v Pt) my '' '` -^' ^ ~ � ^/ � ��� '' r - 4- .L� • � x� �- � . � ��� �� , , �"� . , � �� �' �»*�� ^ w�� " ��^v '�= w " ~�- ' ' �^~~ r "- 4if �~ ' - ' - - ' ^' - �� - ' NOV %� �»w w ��" 1:131.430 DINti3d 4qq, hett„., • dlitiAW 1 . 004413-..• 03A130 T Il ,97-90e/ • • • •0 vi-er?'2 j-zoinoc it OP OrTN-V 47/ 7'Z :43 S .4 , /8 • s • c' iii4 40 - c y v e (v (3 / cl c2 Xa c )-( 7 / - 2 co 0 /c.)C7E 217/ N y 'T7 c7 0 * * REVISION SUBMITTAL DATE /0 -' 3 © '" PROJECT NAME 7 S 7 S eg u l c ADDRESS rl t k /L/4- /o i 3 S P 4C i / i C.- N LIa 9 S. CONTACT PERSON _5 C (r 1 P1 t C PHONE ' ( 1 7 7 5 ARCHITECT OR ENGINEER PERMIT NUMBER (If previously issued) PLAN CHECK NUMBER CITY OF TUKWILA 6300 SOUTHCENTER BOULEVARD TUKWILA, WA 98188 TYPE OF REVISION: 17 J !'T i Ii/ DO/4 30d OD 6 74/ G/r TG /2// . fa ,E6' /14 b fri '67a o A) A- i 1 Es 5 Pec S) SHEET NUMBER(S) "Cloud" or highlight all areas of revisions and date revisions. SUBMITTED TO: h C ' ` V 61 SC ft) a :, Or/ Of TU WILA p CENTER CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD, TUKWILA, WASHINGTON 98188 PHONE N /2061433.1800 Gary L. VanDnsen, Mayor October 23, 1991 Scott A. Pierce AAron's Furnace Works 16904 N.E. 104th Ct. Redmond, WA 98052 RE: System Seven Service, 10835 Pacific Hyw. S. Plan check number 91 -198M Dear Mr. Pierce: After an initial review of subject project, it has been determined that additional information be submitted to complete the plan review. Please address the following comments. 1. Provide heat loss calculations per the Washington State Energy Code to qualify the size of proposed furnace. Note: the suspended heater in the tube area must also be limited to a maximum 49 degrees F or a maximum of 3.4 BTU per square foot, see W.S.E.C. sections 101.3.1.1 and 201.1, (conditioned space). 2. Provide engineering_ calculations details the . _. ..., • existing roof will support the additional weight of the proposed heating units. Engineering must be prepared and signed by a Washington State licensed engineer. Please confirm you have received these comments by contacting this office and /or submit revisions within ten working days. Feel free to call me if there are any questions, 8:30 a.m. to 4:30 p.m. at 431 -3670. dD 1 -S-At +1A�L1a o S UMQ c,ALLep V 1 d t -_ �) et x S T wAsTE Cat L Itulal4SAS ex a m M Oekr Loss 2. .> WILL oU i b er, wSI Gta S Daa Sincerely, Ken Nelsen Plans Examiner • PLAN REVILW CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 PLAN CHECK NUMBER I c 8 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PROJECT: ADDRESS: DATE: Prepared by • 2(_ 1) L. E`TTE. P bo i ) 0 /7-3 1 ( Z) I'W0).1e.: 1 t., ►0A. :- ( - t c 1-I P r - Je.C. 1? C A 14 ED - /Sc--., 10/3c) /41 ( r_ -n r J l prM e.Y 1 ; FD'_ E.m 6i m eG ri t r.1(, 4 )._ Scoff 'PRA p rzc 12. c A M- I ►.s T6 • a,.4. :.. LimTG.0 O (.6/3a/4 I 1,x.1 A s r (� Pra\ . E A7PTh)',V\ _ r_ InJDUL.„.> it oT C L--.T T iea.PC e . .i - E1 Lt--% OT- O F'4- I-11 1r, I4 A't iZVI , KI07 ^ice — TA I t r:) c oR- •=`i"A 1J .. r Tc_ 5) 1 tc..( l`,Ls(.S[ e "ifl. r Axel "l _lnJ 7 A I L �r . tit. Y :5 a NO i Api=6,-. A9 rtAr.-L? Ml lLc, C Lc )›ca To ! T>, K.) 1.7 ` , 0NY. - , - TAt)s>A2� --- I"NI=;t? A-ter Cotoc i Fti LC7wg32 %.62u►Pef,tE v-f ic' l ct t ` OFT' F DO 4 `Pe ri? ( . c:. C i 0 B , PLAN REVILW CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 PLAN CHECK NUMBER I c 8 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PROJECT: ADDRESS: DATE: Prepared by • 2(_ Ductible Model 150 200 300 Input (approx. BTU /hour) 175,000 235,200 350,000 Output (approx. BTU /hour) 150,000 200,000 300,000 Stack size 8" 8" 8" Furnace overall dimensions (L x W x H) includes outs measur of blower and ■ t he burner ements 51 „ x 45” x 36" 51" x 51" x 36" 73" x 57 " x 33" Shipping weight 525 lbs. 575 lbs. 805 lbs. Blower CFM 2,420o .25"sP 2,420o .25"sP 2,860o »sr Duct Openings 231/4" x 23 23 x 29" 23 x 29" Electric power 115VAC 60 HZ 115VAC 60 HZ 115VAC 60 HZ Electric draw 15.8 amps 15.8 amps 15.8 amps Approx. oil consumption 1.25 1.68 2.5 Compressed air (Optional mini compressor available) 2 CFM @ 40 PSI 2 CFM @ 40 PSI 2 CFM @ 40 PSI Oil transfer pump 18 GPH @ 35 PSI 18 GPH @ 35 PSI 18 GPH @ 35 PSI Thermostat 24V Yes Yes Yes More questions? Call Shenandoah or our distributor in your area... Patent - pending burner design with slide -out gun assembly Allows easy access for cleaning of fuel nozzle. Six year limited warranty You are protected on full replacement of fire chamber and heat exchanger during first three years. Limited warranty applies during second three years. Safety features Cadmium flame sensor cell provides automatic cutoff if supply of fuel or air becomes inadequate. Fan /limit control shuts down burner if excessive heat is present. Self:purging fuel nozzle ; Automatically purges nozzle after shutdown. Tubular flow heat exchanger Provides excellent heat extraction and delivers heat at high efficiency. Heat exchanger cleanout panel ,:Allows' easy access for removal of ashes. en controlled Provides 24 -hour ease of operation. ralong'(36 ") preheat path rings compressed air to optimum emperatures for positive ignition and clean urning with, less emission. r ato nozzle hies fuel and air in.a fine mist for best combustion:':.;; eplaceable stainless steel flan* target.:` •Protects firing chamber. Industrial standard components Offers,off-the shelf compatibility for ;;replacement of motors, ignition transform - ers; blowers and,controls. leting„Shenandoah unit heaters can ig raded t�. ductlble models. {:a en andoah le solution! Heating system includes: Transfer pump, suction screen, check valve, thermostat, in -line filter, belt- driven centrifugal blower, 3 washable aluminum mesh filters and 8" barometric damper for stack. When comparing furnaces from different manufacturers... Shenandoah lists BTU input and output to show burner efficiency. The BTU output is the true measure of the heat generated by the heater. Product innovation since 1924... Shenandoah Manufacturing Co., Inc. PO Box 839, 1070 Virginia Ave. Harrisonburg, VA 22801 USA Phone: (800) 476 -7436 or (703) 434 -3838 Fax: (703) 434 -3068 Model 150 200 300 Input (approx. BTU /hour) 175,000 235,200 350,000 Output (approx. BTU /hour) 150,000 200,000 300,000 Stack size 8" 8" 8" Heater overall dimensions (L x W x H) includowes o utsi and the de measu of bl burnrements er 40" x 45" x 36" 40" x 51" x 36" 62" x 57" x 33" Shipping weight 435 lbs. 485 lbs. 715 lbs. Blower CFM (approx. @ .25" SP) 2,500 2,900 3,200 Electric power 115VAC 60 HZ 115VAC 60 HZ 115VAC 60 HZ Electric draw 15.8 amps 15.8 amps 15.8 amps Approx. oil consumption 1.25 1.68 2.5 Compressed air (Optional mini compressor available) 2 CFM @ 40 PSI 2 CFM @ 40 PSI 2 CFM @ 40 PSI Oil transfer pump 18 GPH @ 35 PSI 18 GPH @ 35 PSI 18 GPH @ 35 PSI Thermostat 24V Yes Yes Yes More auestions? Call Shenandoah or our distributor in your area... Patent - pending burner design with slide -out gun assembly Allows easy access for cleaning of fuel nozzle. Six year limited warranty You are protected on full replacement of fire chamber and heat exchanger during first three years. Limited warranty applies during second three years. Safety features Cadmium flame sensor cell provides automatic cutoff if supply of fuel or air becomes inadequate. Fan /limit control shuts down burner if excessive heat is present. Air - operated self - purging fuel nozzle Automatically purges nozzle after shutdown. Tubular flow heat exchanger Provides excellent heat extraction and delivers heat at high efficiency. Heat exchanger cleanout panels Allows easy access for removal of ashes. Thermostatically controlled Provides 24 -hour ease of operation. 'Extra long ,(36'.') preheat path Brings oil and compressed air to optimum temperatures for positive ignition and clean burning, with less emission. Air atomizing nozzle Mixes: fuel and air in a fine mist for best combustion:: • Replaceable stainless steel flame target Protects firing chamber... ,dustriial:standard components Offers off, -the shelf :compatibility for replacement; of motors; ignition transform- ers; and controls; The depen Product innovation since 1924... Shenandoah Manufacturing Co., Inc. PO Box 839, 1070 Virginia Ave. Harrisonburg, VA 22801 USA Phone: (800) 476 -7436 or (703) 434 -3838 Fax: (703) 434 -3068 andoah e solution! Heating system includes: Transfer pump, suction screen, check valve, thermostat, in -line filter, oil and air pressure regulator and 8" barometric damper for stack. When comparing heaters from different manufacturers... Shenandoah lists BTU input and output to show burner efficiency. The BTU output is the true measure of the heat generated by the heater. Make sure you are comparing similar numbers. A tradition of innovation since 1924... C name to trust for STE OIL UT IONS T HINK OF WASTE OIL as an asset! Shenandoah's waste oil solutions are the best news to come along in years, for you and the environment. If you are paying someone to haul away your waste oil, you owe it to yourself to learn more about Shenandoah's success story of innovative waste oil solutions. NOW YOU CAN turn your "cradle to 1 the grave" liability problem into source of free fuel to heat your facility. Shenandoah has the industry's most complete line of waste oil systems. Unit HEATERS Designed to hang from the ceiling or to place above a workbench tank, Shenandoah heaters are warming thousands of auto and fleet service centers from coast to coast. Choose from three model sizes to match your shop size and waste oil output. Owners like the easy cleaning slide out gun assembly. Now you can be generous with your heat. A warmer shop means improved worker productivity. Your Shenandoah distributor has the complete story on these popular heaters. er SING WAST . OIL as a fuel has never been easier. rget the days of smoldering bums and unreliable contraptions. She .:ndoah systems of the 1990's are dependable, dean burning, fuel efficient, and : aded with safety and easy - maintenance - eatures. B EST OF ALL, ou're helping to protect the environn . =nt. One gallon of waste oil can ruin a milk:: : gallons of fresh water. Shenandoah's tee: . eology meets EPA regulations as an cepted method of on -site waste oil d posal. O Ao Solving yo tir Was tE Duct FURNACES If you need to distribute heat through a duct system, consider a Shenandoah Furnace. The squirrel cage fan pushes air across the heat exchanger tubes and sends it through your duct system to remote locations. Shenandoah furnaces are made to deliver 24 -hour dependability. Call your Shenandoah dealer for a no- obligation quote. Offers the be ■ Patent -pc,;; ■ User -frien; Slide out g . Heat exci'r. ■ Extended on fire chc ■ Safe, depe:: Thermostc: Flame sen.;. • Efficient, d. Air atomiz ;: Fuel and c : Stop drip you fits of... . ing burner design maintenance assembly (pictured) cleanout panels •. -rarity r and heat exchanger sable ease of operation controlled ith cutoff controls are combustion iozzle ,, Messed air are preheated prevents carbonizing Hot water BOILERS The Shenandoah Boiler is the only design on the market made exclusively for waste oil combustion. A powerful draft inducer and oversize heat exchanger are two features found on all four boiler models. These boilers are ideally suited for car washes and large garages that need high volume hot water or applications where hot water heat is preferred. Each one is ASME stamped, National Board listed and made by Eshland Enterprises, Inc. (Greencastle, PA). Available nationwide through specially authorized Shenandoah distributors. and heal garb • auto dealerships • truck fleet garages ■ farm equipment deals • transmission shops ■ federal, state, and nu fleet garages ■ bus fleet shops • car washes Firms with an a supply of used c ■ crankcase oil ■ transmission and hyc • other petroleum base (any weight combination up INK OF WASTE OIL as an asset enandoah's waste oil solutions are est news to come along in years, for you he environment. you are paying someone to haul away waste oil, you owe it to yourself to learn about Shenandoah's success story of ative waste oil solutions. 3W YOU CAN turn your "cradle to he grave liability problem into a of free fuel to heat your facility. indoah has the industry's most lete line of waste oil systems. CI SING WASTE OIL as a fuel has never been easier. Forge the days of smoldering burners and unreliable contraptions. Shenando :h systems of the 1990's are dependable, dean burning, fuel efficient, and loaded with safety and easy - maintenance features. B EST OF ALL, you're helping to protect the environment. One gallon of waste oil can ruin a million ga!ions of fresh water. Shenandoah's technology meets EPA regulations as an accepted method of on -site waste oil disposal. Offering yozi the beret. r.. ■ Patent burii.E design ■ User - friendly maintenance Slide out gun assembi; ; "[ ctured) Heat exchanger done, s: panels ■ Extended warranty on fire chamber and h _ :: exchanger ■ Safe, dependable ease of operation Thermostatically control/cc Flame sensor with cutoff car', rots ■ Effident, dean combustion Air atomizing nozzle Fuel and compressed air u r, preheated Stop drip nozzle preven`, carbonizing ;ol vzng your Waste C nit (EATERS Designed to hang from the ceiling or to :e above a workbench tank, Shenandoah ters are warming thousands of auto and t service centers from coast to coast. Choose from three model sizes to match r shop size and waste oil output. Owners the easy cleaning slide out gun assembly. Now you can be generous with your heat. armer shop means improved worker iuctivity. Your Shenandoah distributor has complete story on these popular heaters. Ductible FURNACES If you need to distribute heat through a duct system, consider a Shenandoah Furnace. The squirrel cage fan pushes air across the heat exchanger tubes and sends it through your duct system to remote locations. Shenandoah furnaces are made to deliver 24 -hour dependability. Call your Shenandoah dealer for a no- obligation quote. Hot water BOILERS The Shenandoah Boiler is the only design on the market made exclusively for waste oil combustion. A powerful draft inducer and oversize heat exchanger are two features found on all four boiler models. These boilers are ideally suited for car washes and large garages that need high volume hot water or applications where hot water heat is preferred. Each one is ASME stamped, National Board listed and made by Eshland Enterprises, Inc. (Greencastle, PA). Available nationwide through specially authorized Shenandoah distributors. :auto dealerships: ■ trick fleet garages • farm equipmentdealerships ■ transmission shops ■ federal, state, and municipal fleet garages • bus fleet shops ■ car washes Firms with an on -site supply of used oils... • crankcase oil ■ transmission and hydraulic fluids ■ other petroleum based lubricants (any weight combination up to SAE #50) PO Box 839, 1070 Virginia Ave. Harrisonburg, VA 22801 USA Phone: 1-800-476-7436, (703) 434-3838 Fax: (703) 434-3068 • Waste Oil Heater Manufacturers A ssocia tion Our air emissions laboratory keeps us on the, leading edge of 'combustion technology. Your authorized. Shenandoah Since 1924, a company of innovation hen you invest in a Shenandoah, you have a solid company behind you. We've been making innovative and reliable products since 1924. Products such as Shenandoah wood and coal stoves that helped keep America warm during the energy shocks of the 1970's. etter Solutions From our 100,000 sq. ft. plant, products for poultry farms, veterinarians and medical facilities are made and shipped worldwide. We are an active member of WOHMA, a waste oil industry association that is working for your right to use waste oil as an on-site fuel. We look forward to serving you with a custom solution to your waste oil problem. Call us or your Shenandoah dealer today! 4,-7 • s." 44 •.•;•"! • • • *. • • • at •••11' I underst6nd . that tti6 Plan tiierrprbncianis;tions. arid approval of plan not authorize 1fl6 n&atofl of any adoSted bode or ordinan PP • of : dor- tr*Set6e's..eopy-Of a bproyeci pOns • • • ' • • a.. 1 • . •• I • • , ,,••••If • ."1 4;• r,..4 ^r, ' • • • ..!) • •(.1 • al, . • . • • •••,‘ ? ea. • Li:111,■.i■ a " 1 • 2 3 - .7- I 4 5 6 • c: :s.$ 711:: - • or " • • • . J ••,.• • .fi • 4• W'-7' 4M " o • — , — • • • • • - • - • - • • . • —••• --••• • ■ . •, . 5 4.4 p . • • • 1 "1"i" , !'"' 3 " . "C ••••• ` e ' . • * ' '' t ••••' i . , , ,,,, k , . ' i., . „IN 4V S'r :,/,,,,„,...',. . ., -.... ,r..7 '.47-,..1,,;.1":„."...■/.,, ,v 4,„. . , ...; .V .'''... . ,, 4V-Y,,44,,..I',',' , .Z ',7 Ai:74,4Sr •f„.,Al&r.; ; t „ i :k %, ." s 4?*1.,•re,tr_'; . rie.k .-1 X•C •qk ; Mt ' , c;i. ••''• ••••. '• • J.> 4,.. ••••` V' 3‹.,' . '11,1‘ • , ;: , ,q ,i,,,;..2,... .. ep::: 147. .. .c. •i• SEPARATE PERMIT- AND PPRovk ‘REQutRED ' • ' , ..•••••- • RETc(Rw A • iR gLAcT.r,SLA-LoS 4 :sNtse it)...vQ: LAP • "" A.0 VI II 0 )-( ` • - u•kvvi4eLtz. s P* . , ,r)t)t4-14 "eyist,j' Pt-, .` $76 .: I i z . - - • '7;7." f • - • • RECEIVED, . 1K1Ali t! U . PERMIT CENTER