Loading...
HomeMy WebLinkAboutPermit M94-0099 - BOEING #9-101• ..: t-^,. • . 0". . • C Y Soein Y0099 City o 7�zkwt� Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M94 -0099 Type: B -MECH Category: NRES MECHANICAL PERMIT Address: 9725 EAST MARGINAL WY S Location: 9725 EAST MARGINAL WY S Parcel #: 000340 -0018 Contractor License No: BOEINC294ML TENANT BOEING #9 -101 9725 EAST MARGINAL WY S, SEATTLE, WA OWNER BOEING PO BOX 3707 - M/S 1F -09, SEATTLE WA 98124 CONTRACTOR BOEING INC. Phone: 206 544 -2975 9725 EAST MARGINAL WY S, SEATTLE, WA 981242207 CONTACT TERRY BENNETT Phone: 206 544 -2975 P.O. BOX 3707, M/S 46 -87, SEATTLE, WA 98124 ************,******,************************ * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: RELOCATE DUST COLLECTORS. (HVAC)' UMC Edition: 1991 * * ** *1 * * * * * * * * * * * * * * * * * * * * * ** P rmg;t Center Authoriz:Q Signature Valuation: Total Permit Fee: Status: ISSUED Issued: 07/05/1994 Expires: 01/01/1995 Suite: 100,000.00 30.00 * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** igcly I hereby certify that I have read and examined this permit and know .the same to be true and correct. All provisions of law and ordinances, governing.'this work will be complied with, whether specified herein.or not. The granting of this permit does not presume to give authority to violate or cancel, the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this buil ing pe Date: '7.-5- (206) 431-3670 Print Name: Title: This permit shall become .null and void if the work is not commenced within 180 days from the date of issuance, or if the work',is'suspended or abandoned for a period of 180 days from the last inspection. AMOUNT OWING: <66 3 o. Q v CONTACTED - -ILIA dJ ( 1 V UC.�D0.(/�C,) DATE NOTIFIED I 5 `q+ BY. (init.) SINO 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION BY: (init.) PLAN CHECK NUMBER M911-- OOgq DEPARTMENT BUILDING - initial review O FIRE O PLANNING O OTHER BUILDING - final review (BUILDING OFFICIAL REVIEW COMPLETED CITY OF TUKW 4 Department of Community Development — Permit Ce 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Tracking PROJECT NAME -ED&NOt . I. q-- WI SITE ADDRESS '1 a5 —16T M INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. �TE`I 4 - a7_ C,J. AP:P. ROV ROUTED 1NIT: INIT: INIT1 INIT: CONSULTANT: Date Sent - lUIREMENTS FIRE PROTECTION: • Sprinklers FIRE DEPT. LE ITER DATED: ZONING: SCREENING REQUIRED? Q Yes REFERENCE FILE NOS.: UMC EDITION (year): 0 No SUITE NO. Date Approved - Detectors • N/A INSPECTOR: IBAR/LAND USE CONDITIONS? U Yes U 01/07/93 SITE ADDRESS y 1 SUITE # , / ; VALUE OF CONSTRUCTION - $ /60 t - ' ZIP 98124 PROJECT NAME/TENANT e. BOEING DEFENSE AND SPACE GROUP BLDG. If ASSESSOR ACCOUNT # C _; ye; .. c) /' /.p ADDRESS SAME TYPE OF WORK: ,New /Addition 0 Modifications 0 Repair 0 Other: WA. ST. CONTRACTOR'S LICENSE # BOEING - 294ML EXP. DATE 01- 01 -9.r DESCRIBE WORK TO BE ONE: :,;:, :::::. , > <:::> ::: <:: > >::. :'. '.: :::' :; : ::. » €::: <€ ;: € ; :€ ::::s:: < :: :;;:::;: OP: UNITS; :: :€ .. :TYPE:',.:: ::............... :.......:..: ; RAT1NC�lZE N UMBER :: : :> :: « 5 --1, , r• .E :,, K y ,v /vo c' ..o ze, c / / 1 / .. i7 -cli L., re- , -e . - ► :C= .o ,!".,'' . 7 /)d, % < : Fit/ =, -1 r' BUILDING USE (office, warehouse, etc.) NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE? ' f' o 0 Yes IF YES, EXPLAIN: WILL THERE BE ST GE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? IF YES, EXPLA _ 9.% 0 Yes PROPERTY OWNER BOEING DEFENSE AND SPACE GROUP PHONE 544 -2975 ADDRESS P.O. BOX 3707 SEATTLE, WA. ZIP 98124 CONTRACTOR BOEING DEFENSE AND SPACE GROUP PHONE 544 -2975 ADDRESS SAME ZIP WA. ST. CONTRACTOR'S LICENSE # BOEING - 294ML EXP. DATE 01- 01 -9.r CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 NAME j ((/ JOB # / 7 7/ (i 6 PLAN CHECK NUMBER c+-- 0099 APPLICATION MUST BE FILLED OUT COMPLETELY MECHANICAL PERMIT APPLICATION Mechanical Fee Worksheet must also be filled out and attached to this application. TOTAL` DATE C' f f 7 / PHONE 544 -2975 CITY/ZIP SEATTLE, 98124 PHONE 544 -2975 I. HEREBY'. CERTIFY i HAVE:READ AND, EXAMINED; THIS A PPLICATION AND IA AND'CORRECT AND I AM AUTHORIZED? FO'APPLY FOR THIS PERMIT BUILDING OWNER SIGNATURE OR -G%x Cam; AUTHORIZED AGENT CONTACT PERSON PRINT NAME ADDRESS TERRY BENNETT DATE APPLICATION ACCEPTED 1 TERRY' BENNETT PO BOX 3707 M/S 46 - APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to till out the application completely and follow the plan submittal checklist on the reverse side of this form. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER/AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact theAment of Community Development at 431 -3670. CITY Or TUKWN.A JUN 2 7 1994 PERMIT CENTER FEES (for staff use only) DE5CRIPTION ' PLAN CHECK FEE> ; :4> AMOUNT 15.00. RCPT iti DATE APPLICATION EXPIRES l(9- SAM ETQ t3ET 06/07/93 .. . REGISTRATION NUMBER '. EXPIRATION DATE "01 130E INC*294ML: EFFECTIVE DATE 01/01/95 07/1.3/71 4 DETACH TO DISPLAY CERTIFICATE ' DEPARTMENT OF LABOR AND INDUSTRIES THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A . . . ST CONT GENERAL.. BOEING COMPANY, THE ! I I ' P 0 BOX 3707 MAIL STOP '1F-09 I SEATTLE WA 981242207 •, ii:+wvilrem7vrmyz....r.r.V.v.V=7:72.,■=rets L DETACH TO DISPLAY CFRTIFICATF STATE OF WASHINGTON F625.052.000 (3.921 j ro ec : ( P / U � d Type of Inspect" n: ` � / Address; c l 7 z - S / e. Date Called: 'z-- - --- Special Instructions: 9 Date Wanted: Requester: /o i5,2 Phone No.: INSPECTION RECORD C .: Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 J Approved per applicable codes. ___❑_Corrections_tequired prior to approval. COMMENTS: ' ❑ / $30.00 REINSPECTION FE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. "12ie: PERMIT N0. - (206) -431 - 3670 Project: pro ?--/0/ Type of A "IC Cc-4 Address. 72,-('•' ---:-- /Vim Date Called: i Called: / __- — 9 5 Special Instructions: Date Wanted: 9 )pm. Requester: Phone No.: C INSPECTION RECORD Retain a copy with permit INSPECTIO " 0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 0 Approved per applicable codes. COMMENTS: • 0 Corrections required prior to approval. „ c‘4,47 4,( 61-r e 94-74-? 51-e1-2.%2 I Inspector: 114eit--1N Date: 7 0 $30.00 REINSPECT! N FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No.: Date: / 00 'Ai PERMIT/NV (206) 431-3670 ' • • .• . • • COMMENT (` ) f -1 (1. o' • /fie ufri. *C-r...,/ Cle e , r 19 s- ?1...0 / ex /ci 5, ..•e 401 4 — 4.44 A Aize 0ic� - 4e.-. 4 Li, i a LA" 0.4-7 1.-e-i /›...,we aike.„ % .>"04.c_...0:,5_,___ C .4..74e ' >70 el.. I r?I 64.6 // 2(AV- 4‘..e G../ !^ c-4.. / ,1 ,'G� o �j 0 e.. _ / �, (i . , . .. /.. 1 4 Pl �t t.o . r.Pr 1-•r . 6.e . 1-,u f, II OA , 1 (5 /V-7° 5 h.- .4-7e.-4 6 . C 44.0d-s "40 cs" •440 _ a6- d 71'- t. .t .: i /e-5 T 1--- ..4Grh /00 Jo 4 i • rode " � �. & I -' ype o nspe • . : . A. — Sp: at Instructions: Date Wanted �.. 1 — ... a .m. Requester: L-All yj � : No.. 01 " 1 ! � /�✓ 3 t 4 INSPECTION RECORD C Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ❑ Approved per applicable codes. Corrections required prior to approval. Inspector: ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: v. PERMIT NO. (206) 431 -3670 Ft * *A * **.lt*** * *** tie***** Ak•h* ok• k******* h**** Jr• khyk*hA'**** *****fi'*k***** CITY OF TUKWIL.A., WA TRANSMIT h ** * * * * * * *** *** * * *h * ** * ** * *h ** *•* * * ** **** * *A* #; **** * * *** * *** * ** TRANSMIT Number: 94000800 'Amount: 30.00 07/05/94 13:50 Permit No: M94-0099 Type l3 -MECH MECHANICAL PERMIT Parcel No: .000340-0018 Site Add►^es ;s. '9725. EAST MARGINAL WY S. Locution : 9725.. EAST MARGINAL WY .9 Payment Method :. CASH Notation: HOEING COMPANY In it: SAO, * h***************** *•**, k h************ k* * *,k *kkk * * * **A * * ** * * * * *+k * ;' Account Code Desc►^iption Paid 000/345.830 PLAN CHECK NONRES 6.00 000/3 22.100 MECHANICAL = NQNRES 24.00 ,. Total (This Payment) : 30.00 30.0 30 »00. .00 07/05/94 GENERA GENERA TOTAL CASH 6.00 24.00• 30.00 •.30.00 .. CHANGE. 0.00 3337A000 08:06 Address: 9725 EAST MARGINAL WY S Suite: Tenant: BOEING #9 -101 Type: B -MECH Parcel #: 000340 -0018 CITY OF TUKWILA Permit No: M94 -0099 Status: ISSUED Applied: 06/27/1994 Issued:. 07/05/1994 **•k•k **•k * * *•k *•k * *. *** * ** k•k **** k********• k*• k*• k*' k*• k• k*• k* ** * *•k * **********'k* *•k *•k*•k** • Permit Conditions: 1.. •No" changes w 11 be made .:4 13 'an's;:'�u:ti"es.s approved by the 1•,� Architect and the Te ti �s', s` V •' a�K•r�i�•i�e�' 1'd''ing: "D'fv��s:.i:,dn �t� °w.�„ 2. Electrical permit s ':a`,1.1 •`be ob,ta4ined through'" -.ti etitWashington State Div isi on ,of a Itndustr p es and..,? all `e,):e ,trica1 work will be, (r 'p'ecte�d b t at agency � 30) . ,,, i ,: , � 3. All • permits pi,sp ," c�t1o.n ,ecords, and • approve: pla, } sI '+i.l be ma intained%''� Vai la e ai''" the 3i't'e".�p.r` or� t� .tb v star � f f �. i � � to F7 R '�'' ,? � 'any cons,•r^)ct lore•'�T.hes i) lacu eats are td ma t inec : \ avai.1ab 4 , �unti1r fina1�,`'inspeI rova1 i 4 9,rar onf ,r mance with a ov�ed All co • r uctiof to.Be don c pis q _ plans / � d equ1renn 'nts g .� ,et Unifo Y Building Co '(4 _•3'1 '; '' '`� - i W n to n State B u i l d trig ,sG o d "e� Editi�i'�� a,s amended by �� a 5�1, i .g , g ,� Un i f Dan Mechanical Code:, (1991 ",Edition,) , and Washington , 5at e Ener1 .g.y r Code :(19:91 Second- .Ed1X•i;on) • °; � c� '" .: 5 . V a 1 1 9 , ty''zof; Permit. , The...- i s s ' a n . oaf., a°` ^p ;V .ermit or app.rov. f play s spec ificati,-ons '•arid co, rmO t 3ha1:l be can,- �.s ; s tr'u`e ° d to •be a° permit -f ol; f(o , “ aii` ap' t roy 1• - of<,, any violation.? of Iar�y ,o.f:,,,, . prov i•on;s 4 i3O i s 'a'o a r. of any other �'� "' ordinance .of the'�`,:3uris.d ca i.ct'l•ayr. he ., No "'tp�ermi t,o g i i�,v,g a 1 " its eor v1olate o,r /ince ,.,:'t, pr.av1siols of this) c t¢ s h all be vali ,. y , r ° ,_' - ,, a �:, ,.,.., �. �` BOE/NG JANUARY 24,1995 TO: DUANE GRIFFIN CITY OF TUKWILA 6300 SOUTHCENTER BLVD. TUKWILA, WA. 98188 SUBJECT: PERMIT M94 -0099 DEAR MR. GRIFFIN; BOEING DEFENSE AND SPACE GROUP AT THE DEVELOPMENTAL CENTER AND THE CITY OF TUKWILA BUILDING DEPARTMENT HAVE HAD MEETINGS REGARDING THE COLLECTOR IN THE 9 -101 BUILDING. THE COLLECTOR WAS INSTALLED UNDER PERMIT M94 -0099. DURING THE INSPECTION PROCESS THE INSPECTOR (DAVE LARSON) BROUGHT UP THE ISSUE THAT THE COLLECTOR SHOULD BE LOCATED OUTSIDE THE BUILDING PER THE UNIFORM MECHANICAL CODE SEC. 1105a PAGE 108. WE HAVE ALL OF OUR DRAWINGS REVIEWED BY FACTORY MUTUAL BEFORE SUBMITTING THE DRAWINGS FOR PERMIT APPLICATION.I AM SUBMIT- TING THE LETTER FROM BILL CURRIE WHO IS THE ENGINEER FROM FACTORY MUTUAL ENGINEERING AND TESTING LAB. AS THE LETTER STATES HE FEELS AS DOES THE ENGINEER FROM BOEING DEFENSE AND SPACE THERE IS NOT AN EXPLOSIVE HAZARD IN THIS INSTALLATION. WE ARE ASKING UNDER SEC 106 OF THE UNIFORM MECHANICAL CODE PAGE 3 FOR THE BUILDING OFFICIAL TO REVIEW THE ISSUES AND GRANT THE APPROVAL OF THE COLLECTOR. THANK-YOU FOR YOUR TIME'ON THIS MATTER. SINCERELY f .,G2�,c• -� TERRY ENNETT M/S 46 -87 544 -2975 Boeing Defense & Space Group( P.O. Box 3999. Seattle, WA 98124 -2499 --ps-14-e45 RECEIVED CITY OF TUKWILA JAN 2 5 1995 PERMIT CENTER (9 { )431 ,' 5u.e, 7Zi5 (1c151 k ages( cr n i (e fr P hrl Waita, I/r d j4 , de40(C;,Wr aiioli 604 'vathe a,, ii'o 4(a /Aid 4n/ XCFO 0 c, 0 74 ci Miegj.1% ° e , � /�9Y. ' i II 45,®FZAvc JANUARY 24,1995 TO: DUANE GRIFFIN CITY OF TUKWILA 6300 SOUTHCENTER BLVD. TUKWILA, WA. 98188 SUBJECT: PERMIT M94 -0099 DEAR MR. GRIFFIN; Boeing Defense & Space Group P.O. Box 3999 Seattle, WA 98124 -2499 THANK YOU FOR YOUR TIME ON THIS MATTER. SINCERELY TERRY'BENNETT M/S 46 -87, 544 -2975 -44 RECEIVED CITY OF TUKWILA JAN 2 5 1995 PERMIT CENTER BOEING DEFENSE AND SPACE GROUP AT THE DEVELOPMENTAL CENTER AND THE CITY OF TUKWILA BUILDING DEPARTMENT HAVE HAD MEETINGS REGARDING THE COLLECTOR IN THE 9 -101 BUILDING. THE COLLECTOR WAS INSTALLED UNDER PERMIT M94 -0099. DURING THE INSPECTION PROCESS THE INSPECTOR (DAVE LARSON) BROUGHT UP THE ISSUE THAT THE COLLECTOR SHOULD BE LOCATED OUTSIDE THE BUILDING PER THE UNIFORM MECHANICAL CODE SEC. 1105a PAGE 108. WE HAVE ALL OF OUR DRAWINGS REVIEWED BY FACTORY MUTUAL BEFORE SUBMITTING THE DRAWINGS FOR PERMIT APPLICATION.I AM SUBMIT- TING THE LETTER FROM BILL CURRIE WHO IS THE ENGINEER FROM FACTORY MUTUAL ENGINEERING AND TESTING LAB. AS THE LETTER STATES HE FEELS AS DOES THE ENGINEER FROM BOEING DEFENSE AND SPACE THERE IS NOT AN EXPLOSIVE HAZARD IN THIS INSTALLATION. WE ARE ASKING UNDER SEC 106 OF THE UNIFORM MECHANICAL CODE PAGE 3 FOR THE BUILDING OFFICIAL TO REVIEW THE ISSUES AND GRANT THE APPROVAL OF THE COLLECTOR. Post -Ir brand fax transmittal memo 7671 of pogen to 2- To - I 'co. From '',/ t Co. Copt. Phone* /„6 7 _ Q . /_ .7 �Y� G tlr3 / Fnx I y � Scl � /,.6s Fox q .�I i—} = - - - -= ! i7:0 i FF:011 BUE!NG _E:LF :71 3EHTT-E Factory Mutual Engineering January 18, 1995 Mr. Brian Bailey Fire Protection Engineering Org. 4-3212, M/S 31J-84 The Boeing Company P.O. Box 3707 Seattle, WA 98124 -2207 Re: Dust Collector Installations Building 9-101, Column K13 THE BOEING COMPANY Seattle, WA Index 78840.00 -04 Account 1 -10233 Dear Brian, Favorable conditions include: 10900 N.E. 4th Street, Suite 700 P.O. Box 96077 Bellevue, WA 98009-9677 Telephone (206) 454 -3931 Fax (206) 637.2399 I have reviewed a copy of the City of Tukwila Inspection Record dated December 5, 1994 for Permit No. M94 -0099, and I have made a site visit on January 11, 1995 to evaluate the installation of two Sternvent dust collectors. Based on my evaluation, these installations are acceptable, Because of several favorable factors, no modifications to the systems are required. 1. The collector for ferrous materials does not pose an explosion hazard. The collector for wood, graphite composites and fiberglass impregnated resin materials servos only three relatively small machines: a bandsaw, a disc sander /grinder and a belt sander. The airflow for the collector is 2000 cfm, which is very high for these small machines that are rarely operated simultaneously or for long periods. 2. Based on previous evaluations of similar collected dusts . by Factory Mutual Research Corporation of samples submitted by Boeing, the collected dust is expected to be relatively coarse. It is very unlikely that the concentration of fines in the dust mixture will ever be high enough to produce an explosion because of the coarseness and the high airflow rate. 3. The collectors are located in a normally unoccupied room except for maintenance. This room is provided with adequate automatic sprinkler protection. The collectors are provided with explosion vents which relieve at 3 psi and with vent ratios of 23-to-I. The volume of each of the collectors is less than six percent of the room volume, so there is no room explosion hazard. In the very unlikely event of an explosion in a collector, the loss expectancy is quite low and acceptable. J►;M - 19 -1995 07 :00 FROM / POEM MG SECUR I T`r' SEATTLE TO THE BOEING COMPANY, Index 78840.00, p.2 January 18, 1995 Bill Currie, P.E. Loss Prevention Specialist Seattle District Office 9101cn2 95442854 P.52 ' To summarize, I do not feel that additional venting or relocation of the duet collectors would be cost effective or necessary. Please feel to call if you have any questions. Thank you for your continued interest in loss prevention. Sincerely, Dec 01, 1994 TERRY BENNETT P.O. BOX 3707, M/S 46 -87 SEATTLE, WA 98124 RE: BOEING #9 -101 Syl is Osby Acting Permit Coord ator Department of Community Development City of Tulcvvila John W. Rants, Mayor Department of Community Development Rick Beeler, Director Dear Permit Holder: Our records indicate that on Jan 01, 1995 one hundred and eighty days will have pissed with no inspections having been called for under Tukwila Mechnioal Permit Number M94-0099. Unless you call for an inspection, or obtain a written extension from the Tukwila Building Official prior to that date, your above referenced permit will become null and void on Jan 01, 1995. If your project is complete please call for final inspection. If you are actively working on your project please contact our office. If you have any questions or need further information to obtain an extension on your permit please call the Tukwila Building Divison at 431 -3670. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 4313665 3 O EDG MOLOT BLDGO Oyu VICINITY MAP a I PROJECT I SITE 7 -127 KING COUNTY AIRPORT (ME CENTER (FAA) FROM SEATTLE — TACOMA AIRPORT EAST MARCNAI. WAY CORPORATE PAIN 99 FROM >OWNTOWN SEATTLE 599 TUKWILA 900 DEVELOPMENTAL CENTER FROM KENT & AUBURN Exit 157 NO SCALE BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 AREA MAP BLDG. ADDRESS: 9725 E. MARGINAL WAY S. TUKWILA, WASHINGTON 1 RELOC 9 oat Wi IIR ynqLf 9 -101 BUILDING LOCATION NO SCALE FACILITIES GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO TERRY BENNETT AT BLDG. 9 -51 COL N /1, AFTER COMPLETION OF THIS CONSTRUCTION. PROJECT CHECKLIST CHECK BOX ® THESE DRAWINGS CONFORM TO THE 1988 U.B.C., U.F.C., U.P.C., AND THE 1990 BARRIER FREE CODE AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. ❑ ENGINEERING CALCULATIONS ( IF APPLICABLE ) ❑ ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 33 —A. ® BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: ❑ 1. GENERAL PERMIT (SHELL & CORE) 6 SETS OF ENERGY CALCULATIONS 2 SETS OF CIVIL DRAWINGS WITH UTILITIES 2 SETS SOILS REPORTS, STAMPED BY GEOTECHNICAL 2 SETS STRUCTURAL CALCULATIONS 2 SETS PROJECT CONSTRUCTION SPECIFICATIONS 2 SETS TOPOGRAPHICAL SURVEY 2 COPIES OF LEGAL DESCRIPTION 2 SETS OF WORKING DRAWINGS ❑ 2. TENANT IMPROVEMENTS, 2 COMPLETE SETS O 3. MECHANICAL, 2 COMPLETE SETS ❑ 4. FIRE PROTECTION /SPRINKLERS, 2 COMPLETE SETS ENGINEER ® BRIEF PROJECT NARRATIVE RELOCATE (3) DUST COLLECTORS FROM THE 7 -250 BLDG TO THE 9 -101 BLDG BLUESTREAK MACHINE SHOP. THE FERROUS METAL COLLECTOR AND THE COMPOSITE MATERIAL COLLECTOR WILL BE LOCATED INSIDE AND THE ALUMINUM COLLECTOR WILL BE LOCATED OUTSIDE. THE RELOCATION OF THE ALUMINUM COLLECTOR NECESSITATES A LARGER FAN BE INSTALLED WITH THE DUST COLLECTOR. SEPARATE PERMIT REQUIRED FOR: M ECHANICAL ❑ PLUMBING 0 CAS PIPING c c OF . TUKWILA U DMISION O AUBURN, WA. 98002 0 EVERETT, WA. 98201 O KENT, WA. 98031 O PORTLAND, OR. 97220 O RENTON, WA. 98055 • SEATTLE, WA. 98124 L NES TE 3LU SSW St M' 0 KAM Or CCM Cal AMMO SE TTLE ESTRE LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS TUNNEL FIRST FLOOR MEZZANINE BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC ZONE , ! t. 1 CODE SUMMARY 3 ndetstelno that the Plan Che t 1111.1CC$5011319 and omisslonsen 7n3 does not authorize the . opted code of ot':;7 o '.�`rirWll ctai aco• " TITLE SHEET TUKWILA 1991 UBC, 1994 ENERGY CODE, WASHINGTON STATE BARRIER FREE CODE AND ADDITIONS PER OTY OF TUKWILA GROUP B, DIVISION 2, OFFICE & FACTORY TYPE II, NON— COMBUSTIBLE SEPARATION 60 FEET (MINIMUM ALL SIDES) 713,829 1,116,306 50,910 713,829 55,689 295,878 111 FT. MAXIMUM 2 NO CHANGES BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT A; ?V 30 3° 1994 tt. a JUN 271991 t e at MINI L 9106SZ Al ARCHITECTURAL MASTER -• -- - - -- OAt DRAWING INDEX S DRN NG SHEET TITLE SNOT DRAWING SHEET TITLE Al 9- 101 -Al TITLE 1M12 9- 101 -11112 MECHANICAL MASTER — HVAC PLAN 11118 9- 101 -11118 MECHANICAL MASTER — HVAC PLAN 1M24 9- 101 -1M24 MECHANICAL MASTER — HVAC PLAN M521 9- 101 —M521 HVAC SECTIONS Ic DETAILS 3 O EDG MOLOT BLDGO Oyu VICINITY MAP a I PROJECT I SITE 7 -127 KING COUNTY AIRPORT (ME CENTER (FAA) FROM SEATTLE — TACOMA AIRPORT EAST MARCNAI. WAY CORPORATE PAIN 99 FROM >OWNTOWN SEATTLE 599 TUKWILA 900 DEVELOPMENTAL CENTER FROM KENT & AUBURN Exit 157 NO SCALE BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 AREA MAP BLDG. ADDRESS: 9725 E. MARGINAL WAY S. TUKWILA, WASHINGTON 1 RELOC 9 oat Wi IIR ynqLf 9 -101 BUILDING LOCATION NO SCALE FACILITIES GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO TERRY BENNETT AT BLDG. 9 -51 COL N /1, AFTER COMPLETION OF THIS CONSTRUCTION. PROJECT CHECKLIST CHECK BOX ® THESE DRAWINGS CONFORM TO THE 1988 U.B.C., U.F.C., U.P.C., AND THE 1990 BARRIER FREE CODE AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. ❑ ENGINEERING CALCULATIONS ( IF APPLICABLE ) ❑ ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 33 —A. ® BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: ❑ 1. GENERAL PERMIT (SHELL & CORE) 6 SETS OF ENERGY CALCULATIONS 2 SETS OF CIVIL DRAWINGS WITH UTILITIES 2 SETS SOILS REPORTS, STAMPED BY GEOTECHNICAL 2 SETS STRUCTURAL CALCULATIONS 2 SETS PROJECT CONSTRUCTION SPECIFICATIONS 2 SETS TOPOGRAPHICAL SURVEY 2 COPIES OF LEGAL DESCRIPTION 2 SETS OF WORKING DRAWINGS ❑ 2. TENANT IMPROVEMENTS, 2 COMPLETE SETS O 3. MECHANICAL, 2 COMPLETE SETS ❑ 4. FIRE PROTECTION /SPRINKLERS, 2 COMPLETE SETS ENGINEER ® BRIEF PROJECT NARRATIVE RELOCATE (3) DUST COLLECTORS FROM THE 7 -250 BLDG TO THE 9 -101 BLDG BLUESTREAK MACHINE SHOP. THE FERROUS METAL COLLECTOR AND THE COMPOSITE MATERIAL COLLECTOR WILL BE LOCATED INSIDE AND THE ALUMINUM COLLECTOR WILL BE LOCATED OUTSIDE. THE RELOCATION OF THE ALUMINUM COLLECTOR NECESSITATES A LARGER FAN BE INSTALLED WITH THE DUST COLLECTOR. SEPARATE PERMIT REQUIRED FOR: M ECHANICAL ❑ PLUMBING 0 CAS PIPING c c OF . TUKWILA U DMISION O AUBURN, WA. 98002 0 EVERETT, WA. 98201 O KENT, WA. 98031 O PORTLAND, OR. 97220 O RENTON, WA. 98055 • SEATTLE, WA. 98124 L NES TE 3LU SSW St M' 0 KAM Or CCM Cal AMMO SE TTLE ESTRE LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS TUNNEL FIRST FLOOR MEZZANINE BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC ZONE , ! t. 1 CODE SUMMARY 3 ndetstelno that the Plan Che t 1111.1CC$5011319 and omisslonsen 7n3 does not authorize the . opted code of ot':;7 o '.�`rirWll ctai aco• " TITLE SHEET TUKWILA 1991 UBC, 1994 ENERGY CODE, WASHINGTON STATE BARRIER FREE CODE AND ADDITIONS PER OTY OF TUKWILA GROUP B, DIVISION 2, OFFICE & FACTORY TYPE II, NON— COMBUSTIBLE SEPARATION 60 FEET (MINIMUM ALL SIDES) 713,829 1,116,306 50,910 713,829 55,689 295,878 111 FT. MAXIMUM 2 NO CHANGES BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT A; ?V 30 3° 1994 tt. a JUN 271991 t e at MINI L 9106SZ Al ARCHITECTURAL MASTER -• -- - - -- OAt .- .._._- •••■•••_ 0,41 1• •i 1x 0 DOT. M _._ . _._. _• _._.- FLEX CONN.-••• • - •- •- • -• -• -- EF110 32/20 36/22 FROM DWG r•- O9 •1O1•4583 -M II LJI 64/24 TAME 112E 12 6330 CIM � 2_1 /2S. ••• _ • MINN. • - .r.•._. a•1u Si .. I. ■■ Wean .._ • • • ••• _ • A.H.U. 20000 •■•■•■••••••••••■ 22 14 EL. 12' 4' An •w•■• —•_• .••■•■•■•■•••■•■• RETURN 15215 SCALE: 1/13' • 1' -0' •_._._•••••••■ 125 CF M EA. '= i I 41 IOW MO PIN M. ROI Ma fa eadaelms 'KIND' FA DEPARTMENT •■•■•••■•••••••••■•••■ ._ -_•_- p AUBURN. WA. CI EVERETT, WA. p KENT O PORTLAND, OR. p RENTON, WA. • SEATTLE, WA. 98002 98201 98031 97220 98055 98124 i i l .T._ ......••.... -._. Mgt CONSTRUCTION NOTES: PPORT THE DUCT WORK WITH we ALL THREAD A MAXIMUM OF 10' ON CENTER INTERVALS. VE INTO THE UNRSTRUT CONCRETE INSERTS TO HALO THE ALL THREW. PANT DUCT WORK TO WATCH CEILING AND LABEL AS ALUMINUM DUST COLLECTION WITH LABELS PROVIDED. PROVIDE A WALL PENETRATION ABOVE THE PEDESTRIAN DOOR 0600 ELEV. OF IS'- 10 RUN THE 10' DUCT TO THE OUTSIDE. SUPPORT THE DUCT IMMEDIATELY PAST] THE PENETRATATION WITH UNISTRUT MOUNTED TO THE EXTERIOR WALL. SEAL AROIWID THE DUCT AND PENETRAT ON. INSTALL A DO DEGREE ELL AND ROTATE IT 22.5' OF VEITICA (LEVI EV. OF THE EXIST. ID' D IA DUCT CONNECTION O THEN DUST ELL (FAB ONE BY CUTTING A 90' ELL) FABRICATE ANQ INSTALL A 13' DIA ELL WITH A CENTERLINE RADIUS OF 26 TO THE DISCHARGE OF THE DUST COLLEST4R IT WILL REPLACE THE FAN. FAB t INSTALL A II GA INSTALL MOUNT DUCT LLA 2ND ELI WITH 1 CABINET A266 CENTERLINE RADIUS • IMMEDIATELY AFTER THE MST ELL TO ROUTE THE DUCT DOWN TO THE FAN INLET ELEV. OUTLET APPROXIMATE Y 22' AFG. THIS WILL LINE UP THE ELL WITH THE INLET TO THE FAN. PROVIDE A MINIMUM OF 40' BETWEEN THE DISCHARGE OF THE ELL AND THE FAN THIS WILL HELP tD PROVIDE NON4URBULENT A L FLOW O THE INLET THE FAN. ATTACH THE 13' DIA DUCT WORK TO THE FAN WITH A FLEX CONNECTOR. INSTALL A 12' X 10" TO 13' DIA X 48' LONG TRANSITION ON THE DISCHARGE OF THE FAN. EXTEND A 13' 01A X 0' INSTALLA 0 VELOCITY 0 90 THE WIT TRANSITION. 10" CHpC VALVE INSTALLED TO ALLOW THE FLOW OF AIR OUT OF THE DUCT. THE VALVE MUST PREVENT AIR FROM BEING DRAWN IN. THIS ASSEMBLY IS TO ACT-AS AN EXPLOSION VENT IT IS NOT A 'FUTURE' CONN. THREAD THE THREADED Mb AN GA LOOP MANGER ON TEE. ORIENT ISC GE SO IT IS VERTICAL, ABOVE THE DUCT, IT WILL NOT BE ACCEPTABLE IF IT IS BELOW OR ON EITHER SIDE OF THE DUCT. THE EXPLOSI VENT SHOWN ON THE PLAN IS ROTATED 90' FOR CLARITY. MODIFY DUST COLLECTOR BY STRENGTHENING THE CABINET WITH CHANNEL. THIS IS REQUIRED TO WITHSTAND THE 28" ESP PRODUCED BY THE NEW FAN. Rz 1010 IP 1011 11125 NW INN 11121 11137 NS 1017 • INIS 11124 a 11134 INZ 11131 ri10 11113 1014 1W 11120 MO 1 NU O O IMO 110 . i0 P PLAN a DUCTWORK BLDG. 9 -101,1 MECHANICAL MASTER • - COL. a.-11 /,I..p 9 -101.1 KEY KM ef t JUR 271111 stresi QENERAL NOTES; 1. OILS 14*IIDISTATS LOCATED IN R.A. FOR AHU'S 5 & 0. CMS Ott • alb " . r . 4 i I - a a aI a a . • 1 1 • • .. •■ ■• 201CFM Pao% 15/12 2SICFM 211CFM FLOOR PLAN SCALE: 1 /6 • 1••0 1M18 4553 —M2 4560 —M6 , • _SU OVA 113ANMC1 22/14 rim 1 L`11011 140 1/1n 50 1/2 22/14 FROM MU 111 10/12 1M18 A OMIWPOR OW.) 24/14 1 F ASOSi SO DEPARTMENT (6) 1 CM rA V4 Ci 14• 20/16 QENERAL NOTES; CONSTRUCTION NOTES: EXTEND 10' DUCT FROM UNDER EF01112A NOD ELEV. OF 17' AFF PAST SHEAR WALL OFFSET THE 10' DUCT WITH (2) 45 DEGREE ELLS TO CENTERLINE DISTANCE OF 18 OFF OF THE TRANSPORTATION AISLE WALL AND TO 800 ELEV. OF 15'— 10' AFF. SUPPORT THE DUCT WORK WITH 24' LONG SINGLE CHANNEL BRACKET OFF OF THE AISLE WALL MOUNT THE SINGLE CHANNEL BRACKET TO 081. UNISTRUT MOUNTED TO THE METAL STUDS THAT FORM THE WALL CUT AWAY THE SHEET ROCK AROUND THE STUDS AND BOLT THE 001. STRUT TO THE PROV A PENET TO THE EAST OF THE ROLL UP DOOR NM ELEV. OF 15 10' PPORT THE DUCT WORK WITH I6' ALL THREAD A MAXIMUM OF 10' ON CENTER INTERVALS. TIC INTO THE UNITSTRUT CONCRETE INSERTS TO HANG THE ALL THREAD. PANT DUCT WORK TO MATCH CEILING AND LABEL AS ALUIMNIM 'INSTAALI�A 10X DEGREE E WITH A 10' CHECK VALVE INSTALLED TO ALLOW THE FLOW OF AIR OUT OF THE DUCT. THE VALVE MUST PREVENT AIR FROM BEING DRAWN It THIS ASSEMBLY IS TO ACT AS AN EXPLOSION VENT IT IS NOT A 'FUTURE' CONN. T ROD p MID AN 1 1 G A � LOO OP VALVE P HM GER O TEE. ORIENT DISCHARGE SO IT IS VERTICAL, ABOVE THE DUCT. IT WILL NOT BE ACCEPTABLE IF IT IS BELOW OR ON OTHER SIDE OF THE DUCT. THE EXPL SHOWN ON THE PLAN IS ROTATED 90' FOR CIAR11Y. I 16 11417 I 11122 11423 11424 11413 11419 1M25 11440 I$44 1M14 11115 11420 11421 11426 11442 1144$ 11427 • 11446 '® I • U 9- 101.1 KEY PLAN Ari PLAN - DUCTWORK met " J. el, 1 M18 BLDG. 9 -101.1 1 fin as 11 5' OM TRUNK UNE or Mt 0' OW im* LINE or AFT ■■ ■■ IMO'S i t s t. ONION. Sr 011111=1 5 DIA DUCT TO - I . M CANOE V DIA DUCT TO BAND SAW 5' T DUCT TO —\• BELT SANDER 5' DIA DUCT T0 DISC SANDER ' II V DIA TRUNK UNE • it AFF STERNVENT .KEH24405 sly!: . T COuSCTOR- RATEO— W' TO 2440 CFM 66' ESP. WITH A 5 HP FAN MOTOR i 009 MR 4' DIA DUCT TO THE TABLE SAW HY c V 6' TRUNK UNE • FLOOR 10" DUCT • FLOOR ELEV. BACK TO OUST COLLECTOR i 10' DUCT 017' AFF BACK TO DUST COLLECTOR i 10' DUCT 117' AFF BACK TO OUST COLLECTOR 8' DUCT TO BAND SAW • FLOOR ELEV. ( 5' TO BELT 1M24M 21 SANDER 950 CFM MR I EFO1LI2A i 6" TO BAND SAW 'FLOOR ELEV. I 6" TO DISC GRINDER AND BELT SANDE LvvR-EL[7 7---- i 5' TO EQUIP REDUCE TO 3' TERM. WITH HOSE A WA fa r FACILITIES DEPARTMENT E 1 ROOM 6 Ottr � r " t ilrrlgl0 SO t► .VT. MR iM10 iMib 1042 0 0 0 + 0 0 0 1011 IMi7 1023 10 1Ma iM12 'ma MUD 103! TOO 1M13 iY19 tM$S ii3t INS 1Mi4 1 020 1N46 tM32 to31 1042 11145 0 0 'MIS 1041 1027 1033 1Ma io43 NS O 0 r t 9 •101.1 KEY PLAN DINAR w MM .IDLE a a -- as •••• •u••w S• •.. gaaama..- CONSTRUCTION NOTES: >EX - • BOO ELEV. W I ? AFF F� SCAR WALL 02 T THE DUCT WORK NTH 24' LCNO TINGLE CHANNEL BRACKET OFF OF THE WALL. MOUNT THE MOLE CHANNEL BRACKET TO OR LRRSiRUT MOUNTED TO THE METAL STUDS THAT FORM DE WALL CUT AWAY THE SHEET ROCK MOUND TIE STUDS MD BOLT THE OR STRUT TO THE STUD WTH 34' BONS. T DE DUCT MTH W ALL 1)10. AT MAX INTERVALS . OF 10' QC. USE INC CEILING INSULTS TO HANG THE ALL MD. PROVIDE BRACING KITH SINGLE STRUT ORIENTED AT 45• TWO BACK TO THE CEILING MERE SHORN BY ARROWS. BOLT MOLE STRUT TO II OA LOOP HANGER FOR BRAciNQ T THE DUCT WORK Off OF THE EXIST. MAINTENANCE PLATFORM INSTALL U -CLAMP TO HOLD DUCT TO PLATFORM. TALL FLANGES ON EITHER SINE OF EFOILI2A FAN ACCESS PANEL TO ALLOW MAINTENANCE ACCESS. N 10' DUCT NEXT TO MU TO PROVIDE AS MUCH CLEARANCE AS POSSIBLE FOR TIC LADDER. THE MAMUR CLEARENCE WILL BE APPROX. 24' T iHIE 10' DUCT NTH S2) 45 DEGREE ELLS TO CENTERLINE DISTANCE OF w OFF OF THE TRANSPORTATION AISLE WALL AND TO BOO ELEV. OF 15'- 10' AFF. itafAINT DUCT WORK TO MATCH CEILING AND LABEL AS ALUMINUM OUST COLLECTION MD LABELS PROVIDED. 5' DIA DUCT arm TO THE LOCATION OF THE CONE SANDER USE A S' 90 TEE WE TO DROP DOWN TO FLOC* ELEV. INSTALL CAP ON UN -USED NOR. BRANCH OF TEE -INTEL RUN 5' DUCT TO THE CONE SANDER, INSTALL VERTICALLY ORIENTED BLAST GATE IN THE UNE AND TERMINATE THE UNE WITH A 5'X90 ELL ! 5' RED. TIE INTO THE 6' TRUNK UNE MTH A 6' X Y RED. 90 TEE-WE. INSTALL 6'X5' REDUCER IIMEOIATELY AFTER T -Y RUN A 5' DUCT DOWN THE WALL TO THE BELT SANDER. INSTALL A VERTICALLY ORIENTED BLAST GATE IN THE UNE AND TERMINATE IT UNDER THE EQUIP. DISCHARGE WITH A 90 ELL AND 5' X .V RED. PE INTO THE 6' TRUNK LINE or AFF WITH A 6' X 5' 90 DEGREE TEE -Mt RUN A 5' LINE DOWN TO THE DISC GRINDER. INSTALL DUCT CONNECTION LIKE THE BELT SANDER. PE INTO THE 6' TRUNK UNE germ. WITH AV x 6' 90 DECREE TEE -WYE RUN A 6' UNE 00114 TO THE RAW SAW. INSTALL A VERTICALLY ORIENTED BLAST GATE AFTER THE 1ST ELL ON THE FLOOR. TERMINATE DUCT MTH A 2ND ELL. INSTALL A 6' X 6 IMMED. AFTER THE T - Y. TIE INTO THE 10' TRUNK UNE •IrAFF MTH A 10' X C 90 1EE - 1YYE AND RUN A 4' DUCT TO THE FLOOR ELEV. EXTEND THE 4 DUCT TO THE TABLE SAW. INSTALL A VERTICALLY ORIENTED BLAST GATE AND TERMINATE WITH THE EXIST. 4' x 1Y TO 4' CIA TRANSITION MOUNTED TO THE TAME SAW. OCATE (2) STERNUM 0E1124405 DUST COLLECTORS FROM THE EAST SIDE OF THE 7-252 BLDG. TO THE NEW MECH. ROOM AS SHOWN. POSITION EQUIPMENT TO PROVIDE A MINIMUM OF 36' CLEARANCE ON AU. SDES AND POSTION THEM SO THE ACCESS DOORS FACE THE MIDDLE OF THE ROOM. TIE INTO THE NORTHERN DUST COLLECTOR AND RUN A 10' TRUNK LINE FROM IT THROUGH THE CEILING. ROUTE THE DUCT ALONG PiE MEDL ROOM CAP. UN THE 10' DUCT DOWN TO THE FLOOR ELEV. AS SHOWN AND EXTEND IT ALONG COLUMN RONDE () 3 ' DUCT CONNECTIONS TO NE 0 10'TR UNK LINE WITH 10' X 3" 90 TEE-WYES. INSTALL VERTICALLY THE LINES 0114 A 90 DECREE ELL DIRECTLY UNDER THEE EOM H S DISCHARGE. INSTALL A 10' X 6' REDUCER MMEDIATELY AFTER THE SECOND T - y. ROMDE (4 3• DUCT CONNECTIONS TO THE 6' MUM UNE MTH 6'x3' REQ 90 TEE - IVES. INSTALL VERTICALLY ORIENTED BLAST GATES IN EACH UNE MO TERM THE LINES MPH A 90 DEGREE ELL DIRECTLY UNDER THE EQUIP. DISCHARGE. INSTALL A 8' X 5' REDUCER IMMEDIATELY AFTER THE FOURTH T - Y. XTEND THE 6' DUCT FROM THE 6' x 6' REDUCER TO THE SOUTH WEST CORER OF THE BAND SAW INSTALL A VERTICALLY ORIENTED BLAST GATE IN THE LINE AND TERMNATE THE DUCT MTH A 90 DECREE ELL. N 10' DUCT WORK FROM THE SOUTH DUST COLLECTOR. THROUGH THE MECK ROOM CAP TO i r AFT. SUPPORT THE DUCT AT THE POINT IT PENETRATES THE CAP M1N UNISTRUT AND 10 GA RISER CLAMPS. XTEND THE DUCT WORK or AFF AND AT 45 DECREES OVER THE BRIDGE CRANE DUCT TO MUNN 14. RUN © THE DUCT LINE THE WEST FAACE OF COLUMN 144 AN PRO (2) 6' DUCT CONNECTIONS. THE 1ST CONN. WILL BE MADE NTIi A 10' TO 6' 45 DEGREE WYE. EXTDD THE 6' DUCT TO THE FLOOR ELEV. RUN THE DUCT TO THE GRAPHITE DISC SANDER AND BELT SANDER. INSTALL A BLAST GATE IN THE LINE BEFORE EITHER PIECE OF SOUP. PROVIDE A 5' DUCT CONNECTION FOR THE DISC SANDER 0TH A 6' X 5' 90 DEGREE TEE- WYE. EXTEND THE DUCT UP TO THE UNDER THE EQUIP. OISQIARGE AND REDUCE To 3'. MAKE THE FINAL CONNECTION WITH THE EXIST. 3' FLEX HOSE. INSTALL A 6' X 5' REDUCER IMMEDIATELY AFTER THE W. © EXTEND THE 5' DIA DUCT FROM THE REDUCER TO THE BELT SANDER. INSTALL A VERTICALLY ORIENTED BLAST GATE AND EXTEND DUCT DIRECTLY UNDER THE EQUIPMENT DISCHARGE. REDUCE TO AND MAKE THE FINAL CONNECTION MIT THE EXISTING FLEX HOSE. VIDE THE DO 6' DUCT CONIECTON BY EXTENDING TIE DUCT TO THE FLOOR ELEV. MD INSTALLING A 90 DEGREE ELL TO ROUTE THE 6' DUCT ALONG THE FLOOR TO THE NORM INSTALL A BLAST GATE IN THE LINE AND EXTEND TO THE 6' DUCT TO THE NORTH WEST CORNER OF THE BAND SAW. TERMINATE THE DUCT WORK ND A 90 B; ANT DUCT WORK SAFETY YELLOW AND LABEL AS STEELVIIT COMM NNT DUCT WORK SAFETY YELLOW AND LABEL AS COMPOST /WOOD OUST COLLECTION. trzbPNNT DUCT TO MATCH CEILING AND WALLS AND LABEL AS WM MT COLLECTION �PNNT DUCT TO MATCH CEILING AND LABEL AS COMPOSITE/W000 OUST COLLECTION. M DUCT SAFETY YELLOW AND LABEL AS MA IM OUST COLLECCTION TALL (I) 10' X I0' 90 DEGREE TEE -ME NTH A 1UN10 PLUG TO ACT © AS A CLEAN OUT IN THE MAIN TRUNK LINE. NSTAII. A 10' X 10 90 DECREE TEE -WYE WITH A 10' CHECK YALE INSTALLED TO ALLOW THE FLOW OF NR OUT OF THE DUCT. TIC VALVE MUST PREVENT AIR FROM BEND DRAM IN. TINS ASSEMBLY IS TO ACT AS AN EXPLOSION PENT IT IS NOT A 'FUTURE' CAIN. SUPPORT TIC WEIGHT OF 144E CHECK VALVE FROM THE CEILIN D NTH DREADED ROD ATI AN 11 GA LOOP HANGER ON TEE. ORENT DISCHARGE SO IT IS VERTICAL. ABOVE THE DUCT, IT MU. NOT BE ACCEPTABLE F IT IS BELOW OR ON EITHER SIDE OF THE DUCT. THE LXPLOSNTN ® PENT SHORN ON TIC PLAN IS ROTATED 90' FOR CLARITY. INSTALL A SELF - CONTAINED PROCESS COOLER IN INC COMPUTER ROOM AS PER DRAWING 9- 101 -0521. ROUTE CONDENSATE ORANAGE TO MU PAN et/11 'INSTALL OUST COLLECTOR DISC A fE, DUCT WORK AS PER ORANNO $- 101 -M521 PLAN - DUCTWORK r U M` L affacre 1M24 BLDG. 9-101.1 St� OR Is 137050-s16 Mit • • 30" X 24" DISCHARGE DUCT W /RADIUSED ELL P3$$INVG THROUGH THE CAP. TERM. THE DUCT 8" ABOVE THE CAP. 1 M521 INSTALL FILTER RACK ON DISCHARGE DUST COLLECTOR. RACK WILL HOUSE 2) IS' X 24' X 1' THICK FILTERS IX DUCT TO CAP WITH 3' X 3' ANGLE ..3/4 IRON RIVETED TO SHEET METAL AND BOLTED TO CAP PENETRATIONS FRAMING (SEE ARCH. DWG.) STERNVENT DKEH24405 DUST COLLECTOR RATED TO 2440 CFM 06' ESP WITH SEEL OUST) MOTOR STERNVENT 10KEH24405 DUST COLLECTOR RATED TO 2000 CFM 46.5" ESP, WITH A 5 HP FAN MOTOR (COMPOSITE i WOOD DUST) PARTIAL PLAN: MECH. ROOM @J/13 SCALE: 1/4 "= 1' 0" SUPPORT VERTICLE DUCT IMMEDIATELY AFTER CAP PENETRATION WITH BRACKETS AND RISER CLAMP W/A 22 CENTERLINE ELL DISCHARGE DUCT WORK WITH I' THICK SOUND LINER I l 0 10' OUST COLLECTION DUCT MOUNTED ABOVE CAP 2' WIDE X II GA LOOP HANGER MOUNT TO STRUT BOLTED TO CONCRETE CEILING INSERTS. PROVIDE AT MAX. 10' INTERVALS. FR � , 24 C A SLEAVE THROUGH CAP WITH BAFFLE BETWEEN SUPPLY AND RETURN SIDE. INSTALL GRILLE AND FILTER ON BOTTOM OF CAP M521 M521 LIEBERT MODEL /MMEOIBA -POI SELF - CONTAINED SPOT COOLER RATED TO 16,600 BTU /HR 675 CFM MOUNTED ON ' TOP OF CAP LIEBERT MODEL /MMEOIOA -POI SELF - CONTAINED SPOT COOLER MOUNTED ON TOP OF CAP ON A 4' HIGH CURB DETAILED ON THE ARCH. OWLS. ...../Z--- SUPPORT VERTICLE DUCT 47'AFF WITH BRACKETS i II OA RISER CLAMP ON STRUT MOUNTED TO STUDS IN WALL 10' DIA DUCT BACK TO DUST COLLECTOR W/ TROD FROM 2' WIDE II GA LOOP STRAP AND B-LINE EYE - SWIVEL. MOUNT TO CEILING WITH UNISTRUT. B' DUCT TO BAND SAW SUPPORT HORIZONTAL DUCT ON DOUBLE STRUT BOLTED TO FLOOR OR CAP. FIX THE DUCT TO THE STRUT WITH AN II GA DUCT STRAP FABRICATED AND INSTALLED BY CCU. PROVIDE SUPPORT AT A MAX. INTERVAL OF 10' ON CENTER. SECTION: DUCT WORK @L/14 SCALE: 1/4" = 1'— 0" i SUPPORT VERTICLE DUCT B9'AFF WITH BRACKETS i II GA RISER CLAMP ON STRUT MOUNTED TO COLUMN USE 1/2' DIA BOLTS WITH 2' EMBED TO MOUNT TO COLUMN. 6' DUCT TO DISC GRINDER AND BELT SANDER SUPPORT DUCT 010' 0 C. INTERVALS OFF OF FLOOR W/DBL. STRUT. 1M 4 1521 HIGH VELOCITY STACK W/A 14' INLET 6 15' DISCHARGE. SUPPORTED FROM PAD WITH CHANNEL AND II GA RISER CLAMP. SUPPORTS WILL BE DETAILED ON ARCH. OWLS 12' X 10' TO 14'0 X 48' L 16 GA SQUARE TO ROUND TRANS. MOUNTED DIRECTLY TO THE FAN DISCHARGE CHICAGO BLOWER CO. MODEL I3-LS BLOWER RATED TO 3000 CFM 428' WC ESP WITH A 25 HP, 460 V, (3) PHASE PREMIUM EFFICIENCY MOTOR WITH PAYER FACTOR CORRECTION TO 95%. DBL STRUT STANCHEON SUPPORT WITH 'T' CROSS MEAGER TO ATTACH TO DUCT WITH GCU FABRICATED AND INSTALLED II GA DUCT STRAP. MOUNT STANCHEON TO PAD WITH B-LINE /B28IS0 POST BASE. BOLT STRVT TO CONCRETE INSERTS WITH 1/2 0 STUDS STERNVENT DKEH360072 DUST COLLECTOR RATED TO 3000 CFM. (ALUMINUM DUST) 13' DIA X 90' ELL W/A 28' CENTERLINE RADIUS (TYP 3). 58' a T 72' MIN. 48 2' WIDE X II DA LOOP HANGER FAB. AND INSTALLED p CCU. CONNECT LOOP TO 3/8 0 TID. ROO WITH A B -LINE EYE SWIVEL AND 1/2' BOLT. COMIECT ALL THREAD TO BBL. STRUT BOLTED TO CEILING INSERTS. PROVIDE AT MAX. 10' INTERVALS. DETAIL: DUCT WORK HANGER NTS J r -I r - -� I I I I I II I 5' -11' 22.5' • SECTION: ALUMINUM COLLECTOR ©M /1 SCALE: 1/4" = 1'— Or St •8• •", " M521 M521 • SUPPORT DUCT WORK 015'— 10" AFG WITH BRACKETS Ul II CA LOOP STRAP ON STRUT MOUNTED TO BUILDING FACE rc 1M12 1 521 IF BRACING IS REQUIRED BOLT TO II GA OPEN NGLEE INS THE 3' LONG SIDE SIDE WITH THE UNISTRUT. TIE THE UNISTRUT • CHANNEL BACK TO THE CONCRETE INSERTS IN THE CEILING. I I I I i I I I I I I I I I I I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 I I I tIBM T ;0111111111 I r I I t I A P ROVE 30 1 Y� H, tiU1cU OIIV Or 11�AWA nr3 F,.��LV JUN 2:7 In SECTION: MECH. ROOM @J/13 Mc14 a 0099 SCALE: 1/4" = 1'— Or Atrnoll - ... en h MIR AEI ISMS A MX FACILITIES .r<an A woI" ' Artm AAMNq IN wr. SOW SECTIONS & DETAILS BLDG. 9 -101 MECHANICAL MASTER J- N/11 -16 O.C. M521 137060 -1s 0- 101 -Meat