Loading...
HomeMy WebLinkAboutPermit M94-0135 - BOEING #9-101triti Bpi r .g n . tiJ DOD 146 414101 n015 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M94 -0135 Type: B -MECH Category: NRES MECHANICAL PERMIT Address: 9725 EAST MARGINAL WY S Location: Parcel #: 000340 -0018 Contractor License No: BOEINC294ML TENANT BOEING #9-101 9725 EAST MARGINAL WY S, TUKWILA, WA 98168 OWNER BOEING PO BOX 3707 - M/S 1F-09, SEATTLE WA 98124 CONTRACTOR BOEING INC. Phone: 206 544 -2975 9725 EAST MARGINAL WY S, SEATTLE, WA 981242207 CONTACT TERRY BENNETT Phone: 206 544 -2975 P.O. BOX 3707, M/S 46 -87, SEATTLE, WA 98124 ******************************************** * * * * * ** * ** * * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALL TUBEAXIAL FAN. UMC Edition: 1991 Valuation: 10,000.00 Total Permit Fee: 24.38 ******************************************* ** * * * * * * * * * * * * * * * * * * * * * * * * * * * ** bi` c 1�J q[1 Permit Center Authorize Signature Date Print Name: (206) 431 -3670 Status: ISSUED Issued: 09/16/1994 Expires: 03/15/1995 Suite: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building perm Signature __ Title: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or If the work is suspended or abandoned for a period of 180 days from the last inspection. AMOUNT OWING: # aOS CONTACTED Ti )2.Ala vb'» C DATE NOTIFIED - /5 -CP1- BY: (init.) 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION BY: (init.) PLAN CHECK NUMBER Makt--0 135 CITY OF TUKW . 4 Department of Gmmunity Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Tracking PROJECT NAME 130 F:,1 ct— I o 1 SITE ADDRESS EA-5111 ;,+JA -I IAA S SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. EPARTMEN O PLANNING O OTHER KBUILDING - final review BUILDING OFFICIAL TEI PPROVE BUILDING - g _ 3 - V initial review 7 ' ROUTED O FIRE GA/ CONSULTANT: INII: INIT: INIT: 4 1/5/4 R. INIT: h INIT: UIREMEI Date Sent - IMMEt Date Approved - FIRE PROTECTION: • Sprinklers U Detectors ON /A FIRE DEPT. LETTER DATED: ZONING: INSPECTOR: BAR/LAND USE CONDITIONS? CJies No SCREENING REQUIRED? Q Yes 0 No REFERENCE FILE NOS.: UMC EDITION (year): REVIEW COMPLETED 01/07/93 SITE ADDRESS / # 7 g sue, ... . A, 44 t& t 7& 7 VALUE OF CONSTRUCTION - $ /O coo ASSESSOR ACCOUNT # e,06, 3 v ._p / J 44 - 2975 PROJECT NAMETT /ANT BOEING DEFENSE AND SPACE GROUP TYPE OF WORK: ,New /Addition 0 Modifications 0 Repair 0 Other: CONTRACTOR SAME DESCRIBE WORK TO BE DONE: ADDRESS <:' <'::::::<! >::::`0 �`::��.: >:::: ,<.:;;.:�::<:::, >;:::;::; ..�.::. � �<> ::: �;.:.::; �::>::: �:::::»;::; �:.;:;::::< :::::�:.::.::: >�:�:;;NIJM�AUF- NIT . TYPE..., ::.. .::. 6F MOO A , Ft1N Ctzivt ( •H P 1 LW T BUILDING USy (office, warehouse, etc.) NATURE OF BUSINESS: AIRPLANES WILL THERE BE A CHANGE IN USE? ' No ❑ Yes IF YES, EXPLAIN: WILL THERE BE ST. • . GE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? IF YES, EXPLAI(g, ❑ Yes PROPERTY OWNER gOEINu PHONE 44 - 2975 ADDRESS PO BOX 3707 M/S 46 - SEATTLE, WA. ZIP 98124 CONTRACTOR SAME PHONE ADDRESS ZIP WA. ST. CONTRACTOR'S LICENSE # BOE INC 294ML EXP. DATE JAN. 01,1994 CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 �#�G�1•-t� (206) 431 -3670 �, P l= N 1C. f-C Nr� PLAN AN CHECK • NUMBER mq(-1- 0155 APPLICATION MUST BE FILLED OUT COMPLETELY piEBY CERTIFY THAT:t NAVE fIEAp. :M..D;;EXAMINPD;T AND:COARECT AM AUTHORIZEIJ TO APPLY 1=0Fi BUILDING OWNER SIGNATURE OR AUTHORIZED AGENT ADDRESS BOX 3707 M/S 46 -87 BENNETT DATE APPLICATION ACCEPTED AUt 3 0 1994 PERMIT CENT MECHAK CAL PERMIT APPLICATION Mechanical Fee Worksheet must also be filled out and attached to this application. FEES (for staff use only) BASIC _PERMIT FEE T() OTHER y50U RCPT::; PER PHONE 544 -2975 CITY/ZIP SEATTLE . 98124 DATE CONTACT PERSON TERRY BENNETT PHONE 544 - 2975 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to till out the application completely and follow the plan submittal checklist on the reverse side of this form. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER/AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any quEstiauswbout our process or plan submittal requirements, please contactga MAVIM* of Community Development at 431 -3670. DATE APPLICATION EXPIRES 06107193 . 5rice/. (0 . /a/ ype o ns . Addrel 5 — f mi di vi .56 . Date Called: g4 Date Wanttl /all 9, T p.m . Special Instructions: /Co r . pf Requester: i /99ith A' Phone 41 — OU Y INSPECTION RECORD L_ Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206) 431-3670 Approved per applicable codes. ______ELCoffectIons required prior to approval. o $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Rece01 No.: Date: COMMENTS: i tJS rkt-LATLct rJ 1 s P ill LA-1%4 Spec S. . `-1 i»1 'Fell.._ 4 C +LESS t S p N Li foss t eur oi v‘ )CC ■ .zi. el.A•a -- r-w - - F.D. Arc L S ()also— , s "M - d FA N.- A nJ 9 t S rvoyJ ins ep Ferri- vas LAAL- (0 I °Q.1%4 €S 0 J , r' De?INA - i tv c TO y S C.NSS j O Fc.t 0 cr r, of E S `j SIVIT. 1)J CA-Sc o f F. 1D, Gt_oS ft-£• -C a 1 Pk vtS-co /-) F 1Z-- 1/45 141.it ^t 0Q.1 Q7 0 F - F i W& Ov C3(51) F ImI4X • P") A a t W 4-6 ck-- vri n P' ( L c %j 16-€P, qt A 41q PE:70ADP (6SS- 5331 (e _ 4 ok-To uS1c,,s1s1V) ■ .Ni)L nmjlFco o'S'11€xArW. • ro ect: , r / O rd ype o nspect on: , .mss ���� i ress: la -, a l a ; ::..:. - .F7� Spec al Instructions: , /57 qt Date Wanted: . p.m. Requester: _ 1, ' INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ❑ Approved per applicable codes. (206) 431.3670 Corrections required prior to approval. nspector: tritia=1111111111111111111111M13111111 ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Recept No.: Cafe: Lie-. • G[_f , I u • POTTORFF n o w • ee 0 00 a �ap°VC o0 C ob ° O s g Op�g ti o ° �,r r off' ot°; ; a e QVo ° a eia000 00o��0�og� a °J�°wb�p ° °tiba°°�aK °ei „ : .....1611 ■ 4 1 6 4 .61.2_ 1; eral SERIES VFD -10 model VFD -10 19B curtain fire damper �1 U L usrEo TESTED PER U.L. 555 U,L SR 11767 •• A V C LISTED PRODUCT CONFORMS TO U. B. C. 43.7 CONFORMS TO N. F. P. A 90A CSFM 9225360 :101 Damper Installation For Typical Damper Installation For Typical Fire Rated Partition Flange Termination with Grille / Register . Standard wood or steel framed fire partition with single header and fire rated material lining the opening. Lining not required at stew framing or concrete or masonary (see installation instruction supplement), Opening shall be a minimum 1/8" per foot larger than the overall damper and sleeve assembly slze. Maximum opening size shall not exceed 1/8" per foot plus 1". Opening shall not be less than 1/4" larger than any size damper and sleeve assembly. Duct to damper sleeve connection shall be break away style. Rectangular ducts shalt use one or more of the following connections: plain S -slip, hemmed S -slip, standing S -sup, and other similar and commonly used slip type joints. Ductmate may be used in lieu of slip joints provided that corners are not bolted and non•metalic cleats are used. Round ducts shall use draw band type connections or Pottorff supplied break -away cap / collar assembly. Sleeve through wall shall extend approximately 3" minimum beyond the partition up to a maximum of 16" when supplied with factory installed access door, C, Mounting angles shall be a minimum of 11/2" x 11/2' x 16 gauge. The angles should be attached to the sleeve, not the partition, with No, 10 sheet metal screws, or welds, or 1/4" x 20 bolts at 6" o.c. maximum (staggered on both faces). A minimum of two connections per side, top, bottom. Mounting angles shall overlap the wall a minimum of 1" and shall be overlapping non- connected at the corners, On flange termination units sleeve flange may be used in lieu of mounting angles, D. On non - integral sleeve/irame units the fire damper shall be attached to a minimum 20Ga sleeve by welding, or with rivets, or with No. 10 sheet metal screws, or bolted with 1/4" x 20 bolts at 6" (),c, maximum (staggered on both faces). A minimum of two connections per side, lop, bottom, Multiple section units should be connected at the center rnullin with welds, rivets, No. 10 sheet metal screws, or 1/4" x 20 bolts at 6" o.o. maximum (staggered on both faces) with a minimum of two fasteners on each side of the frame. Maximum multiple assembly is 120 wide x 80 high • made -up of 40 x 40 single sections. Individual damper maximums are 48 x 48 or 40 x 60 (CSFM Only), • Suitable access should be provided for inspection and servicing of fire damper. VFO-lo 3 -0.92 POTTORFF COMPANY INC. 700 SOUTH VAIL AVENUE MONTEBELLO, CA 90640 (213) 728.0004 Nominal Duct Height Blade Stack "C" 2••24" 2" 25 "•38• 3" 37" -49" 4" r 50 "•55" 5" y �cr co 7'4 eJ. GlI - I'I t J ELL CO POTTORFF • • Model VFD•10 ISB for vertical mounting 12" BTD. 2" --I • �..-•- Optional square to round cap & collar (Model VFO -10 ISBR) Optional 14" &16" available (20 guage only) 0.118" • 11/2 HOUR RATED FOR USE IN 1 HOUR OR 2 HOUR PARTITIONS • UNDERWRITERS LABORATORIES FILE #R 11767 • CAUFORNIA STATE FIRE MARSHAL FILE #3225 - 366:101 • VERTICAL MOUNi1NO POSITION F F . 3/4 SERIES VFD -10 model VFD -14 ISB curtain fire damper (DUSTED TESTED PER U.L. S55 CONFORMS To U. a. C 43.7 CONFORMS TO N. F. P. A 90A SI3ECIFICATION • Integral 20 GA. steel frame/ sleeve. • 22 GA, steel interlocking blades, • U. L approved fusible links (165 °F. STD.) • All riveted construction -no welding. • All steel parts with galvanized finish or zino plating. • Installation instructions provided with units. • Maximum individual section 48 1 )(44" or 40 "x55 ". Maximum multi - section 120 "x76 ". Minimum size 6 "x2 ". Units exceeding single section limits are provided as multiple units for field assembly. • Sleeve 0. D. is duct size plus blade stack C. FEATURES • Integral frame /sleeve allows for competitive pricing and installation. • Standard unit requires no additional sleeve for installation. • Available in 304 Stainless Steel. Maximum single section 24 "x22 ". Maximum multi- section 48 "x22 ". Model VFD -10SS ISB. • Styles B and BR are for medium pressure systems. Blades removed 100% from air stream. • Round transition caps and collars are provided on BR models. Rev. 10.29.91 POTTORFF COMPANY INC. 700 SOUTH VAIL AVENUE MONTEBELLO CA 90840 (213) T28.0004 REGISTRATION NUMBER EXPIRATION DATE •' 01 BOEINC*294ML • EFFECTIVE DATE 01/01/95 07/1.3/71 .+ :il.��ll•i� ?:.- ar�.�s`l•.i +.;+! n�'.+LH:.Ie%�'. �:Y,��..rx�i�.'J'.S'.t AFH•s CON ST CONT GENERAL. BOEING COMPANY, THE P 0 BOX 3707 MAIL. STOP 1F -09 F SEATTLE WA 981242207 r - DETACH TO DISPLAY CERTIFICATE - DEPARTMENT OF LABOR AND INDUSTRIES THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A t DETACH TO DISPLAY CFRTIFICATF .i STATE OF WASHINGTON F625-052-000 (3.921 `Accnunt Code ' � 000/34 80O/3'n.100 ^` � Tot#l' Total All • . Bolance: - Description PLAN CHECK - NONRES MECHANICAL -'NONkER Total (This Payment): ' ****4+A***4a*+*+A*a+***+AkA*A*A***a**+**A*+*A+**x++A*+**«*+*^*A+ CITY OF TUKNILA, WA � .� ' TRANSMIT *+*a*+*a****h+*k+*A****a*A***a****a+*****+A*a****Ak**+*A*+k**+** TRRNBMIT Number: 94OQ12O6 Amount: ` `�� � 24.38 09/16/94 09:20 ' Permit No: M94~0135 Typm: 9_MECH MECHANICAL P Parcel No: 00040-00 Q ^~'' b1�e Address: 9725 EAST MARG%NAL`WY S ` Payment Method: CHECK Natation: 11RRY BENNETT GL8 *it+***A*a+***+++***A+af Paid 4.88 19 .°� :24.Q8 34.39 ' .00 `_` GENERA 4°88 GENERA 19"50 TOTAL 24°39 CHECK '' 24.38 CHANG 0°00 5726A000 15:37 vc; A ,. Address: 9725 EAST MARGINAL WY S Suite: Tenant: BOEING #9 -101. Type: B -MECH. Parcel #: 000340 -0018 CITY OF TUKWILA • k• k• k• k***• k****k*• k******• k** Ik*** k***• k***• k**Ik* ** *•k•k* * *•k•k* *•k•k•k*•k k***** k•k *• It *'k*k•k k Permit Conditions ,,, , 1 . . `No changes' w i l l be made to he� 1at if " �Up'1.e : s. a roved by the Architect and the T,� t v T, '-� ufTd i ng U ri1 s =f:on ,, 2. Electrical permit„ d • s.ia1•1 be ob,�tained throug keNWa,shirigton State Divisior,4f.: tees and1 al l e•1 t'abotz " I1 us ` '�� � a � � ' tr ical 4r+'' � t � f work will • be "i petted 4 t a ge.ncy, (24 6 3})) 1 .."\.,, ' '� 3. All • perms tg`(�` .gior records, and arpprdve'i, pla ns `sh i 1 be ,�"d��+' r�„ � d a � i r � .�• maintained a•iai ab' ,e , ,thee ` t`e d pr�itor it s tar t any const ct.thif . "hes u e is are to "�b�e, ma i�Itdi� ed ava i l a / ' f i l'ia .�i nspec ' 4404-,oval l i s g,r•ari eu 4 Al) co 1~ r uct i a t 'be d n /i'i confr i•mance wit 6 a plansfd` quirements�'c}. tli Uniftr Building C8�}ie'( Edit A7) iS amended b ,,,�:i~`he Wa .1, i,rn, on State Build irpg 4 Unit''r` Me'c ' an1pal Code„.(1991 d.tlo ), and Washingto • Ene g Cede (19.91 .Secd Td~- Ed. . �.,r' It 5. Val/ ty - 4 ce ofi� a' `�(',e•r,m1,t or appr�ov i pi y? specifications and l pat ibn aha. not be Omit str led to be a 'per mi ~f or, ' , a �rv'a l o any vionlat,ion of a y , of = - -o f it it s r =• and :o of. aany others 0 or 4 ance� of the , s:d c t 1or1' N `pe,r�m�i't p r y � esuming . to g3l�.ve au hori pr violate of be va41 id% u" °" cancee **the qovisions of this'; code ; r o %.. \ Ni N., .::.a..,t�sa„ 0 4 f z'uds? y o •n Permit No: M94 -0135 Status: Applied: Issued: ISSUED 08/30/1994 09/16/1994 Mechanical Permit Pans Checklist MECH-CHK • • 1204 Washington State Energy Corte Compliance Forms April. 1994 Project Address 'Date The following information Is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability Code (circle one) Section Component Information Required Location 1 on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1 1411 I performance yes no n.a 1411.4 Pkg. elec. htg.8, clg. List heat pumps on schedule Z5 no . 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency 1412 'HVAC controls yes no --, 1412.1 Temperature zones Indicate locations on plans Indicate 5 degree deadband minimum yes no . 1412.2 Deadband control yes no . 1412.3 Humidity control Indicate humidistat yes no it 1412.4 Automatic setback Indicate thermostat with night setback and 7 different day types Indicate damper location and automatic controls yes no It, 1412.4.1 Dampers - no ur. 1412.5 Heat •Um • control Indicate micr• •rocessor on thermostat schedule yes no "''.. 1412.6 Combugtion htg. Indicate modulating or staged control yes no It 1412.7 Balancing Indicate balancinzfeatures on plans yes no f 1422 Thermostat interlock Indicate thermostat interlock on plans yes no ( 1423 Economizers Equipment schedule 1413 Air economizers yes no 1413.1 Indicate 100% capability on schedule Indicate controls able to evaluate outside air ,Operation yes no . 1413.2 Control yes no 63. 1413.3 Integrated operation Indicate capability for partial cooling . 1414 Ducting systems yes no • 1414.1 Duct sealing Indicate sealing necessary Indicate R-value of insulation on duct yes no . 1414.2 Duct insulation yes no i. 1415.1 Piping insulation Indicate R-value of insulation on piping yes no . 1424 Separate air sys. -, Indicate separate systems on plans ..-- yes r Mech. Sum. Form Completed and attached. Equipment schedule with types, inpoutput, efficiency. cfm, hp, economizer SERVICE /VATER HEATING AND HATED PO�LSjsections 1-1454) 1440 - " .. Service water htg. I yes no S. . 1441 Elec. water heater Indicate R-10 insulation unoer tank yes no 1442 Shut-off controls Indicate automatic shut-off 1450 Heatedpools . . yes no J. 1452 Pool water heaters Indicate not electric resistance yes no 1453 Pool heater controls Indicate switch and 65 degree control • yes no 1454 Pool covers Indicate vapor retardant cover yes no 1454 Pools 90+ degrees Indicate R-12 pool cover 1994 Washingt r State Nonresidential Energy Coder mpliance Form no " i circIed for any question, provide explanation: C ts CoosIDete.) Jils A sinifcE 61\- S`1'Cre> RECEIVED CITY OF TUKWILA AUG 3 0 1994 PERMIT CENTER ono VICINITY MAP 99 PROJECT SITE 7 -127 K COUNTY ArRPGRt Off ICE CENTER (FM) 99 d FROM SEATTLE- TACOMA AIRPORT EAST MARGNAL WAY CORPORATE PARK FROM OWNTOWN SEATTLE C 599 TUKWILA DEVELOPMENTAL CENTER FROM KENT & AUBURN -- EMT 5i 157 \ 900 NO SCAT F or IMP ENG Da DAtt one DEFENSE 1 11R FR ME 9 BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 AREA MAP BLDG. ADDRESS: 9725 E. MARGINAL WAY S. TUKWILA,WASHINGTON er 9 -101 BUILDING LOCATION SAW FA sTssAvo NT NO SCALE SP ❑ AUBURN, WA. ❑EVERETT, WA. O KENT, WA. ❑ PORTLAND, OR. CE GR 98002 98201 98031 97220 C NFERENcr, GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY All DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO TERRY BENNETT AT BLDG. 9 -51 COL N /1, AFTER COMPLETION OF THIS CONSTRUCTION. CHECK BOX PROJECT CHECKLIST IN THESE DRAWINGS CONFORM TO THE 1988 U.B.C., U.F.C., U.P.C., AND THE 1990 BARRIER FREE CODE AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. O ENGINEERING CALCULATIONS ( IF APPLICABLE ) O ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 33 -A. ® BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: O 1. GENERAL PERMIT (SHELL & CORE) 6 SETS OF ENERGY CALCULATIONS 2 SETS OF CIVIL DRAWINGS WITH UTILITIES 2 SETS SOILS REPORTS, STAMPED BY GEOTECHNICAL ENGINEER 2 SETS STRUCTURAL CALCULATIONS 2 SETS PROJECT CONSTRUCTION SPECIFICATIONS 2 SETS TOPOGRAPHICAL SURVEY 2 COPIES OF LEGAL DESCRIPTION 2 SETS OF WORKING DRAWINGS ® 2. TENANT IMPROVEMENTS, 2 COMPLETE SETS ❑ 3. MECHANICAL, 2 COMPLETE SETS ❑ 4. FIRE PROTECTION /SPRINKLERS, 2 COMPLETE SETS • BRIEF PROJECT NARRATIVE INSTALL A NEW EXHAUST FAN TO PROVIDE GENERAL VENTILATION OF A RELOCATED OVEN. rh qq 0 1 35 LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING CROSS TUNNEL FIRST FLOOR MEZZANINE BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC ZONE CODE SUMMARY TUKWILA 1988 UBC, WASHINGTON STATE ENERGY CODE, WASHINGTON STATE BARRIER FREE CODE AND ADDITIONS PER CITY OF TUKWILA GROUP B, DIVISION 2, OFFICE & FACTORY TYPE II, NON - COMBUSTIBLE SEPARATION 60 FEET (MINIMUM ALL SIDES) 713,829 1,116,306 50,910 713,829 55,689 295,878 111 FT. MAXIMUM 2 NO CHANGES I mederstnd Ent T1n Pica C~- • Pact to errors end omiulora : cf /Yno don not gal a its i4MiIiom ci ANON sab M oe111lta F i M contain 99 9: 1 9 fr e palpi agiader Osls, 9 — ,G � romil PIN REVISIONS NO CHANGES SHALL TIE MADE TO THE SCOPE OF WORK WITHOUT PRIOR APPROVAL OP TUKWILA MOO nON. Sans NOM eon So MOM A MOP woun ll ns Iw NO V MOITIO N wig. CITY APPROVED ITRIVATA SEP 1994 „ BUILDS arertiltfau AIM 9 01994 m arna DIVISION BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT 3 PILE COPY B/ AM PERMIT REQUIRED r rot ,: O PLUMBING 0 am PIPING CITY OF TUKWILA MILMO DIVISION ACCEPTAMUTY nit otsa. a*j/OI1 ltQai'wl H AM110K0 Af'ROVED h I Ot01. I DAMS MIN e. o.a CHESIDIntio ocean 111011. J t —J .=J OM S AW ya not TITLE SHEET A d /'s1 1 1 err- -re II % A I A• a Oft •w l ber tAff RYl t I I'iM I DAM; Al DRAWING INDEX SHEET DRAWING ■ SHEET TITLE NO. �__ N0. { Al 9- 101 -AI TITLE SHEET N0. DRAWING N0. SHEET TITLE 11111 9- 101 -1M11 MECHANICAL MASTER - HVAC PLAN ono VICINITY MAP 99 PROJECT SITE 7 -127 K COUNTY ArRPGRt Off ICE CENTER (FM) 99 d FROM SEATTLE- TACOMA AIRPORT EAST MARGNAL WAY CORPORATE PARK FROM OWNTOWN SEATTLE C 599 TUKWILA DEVELOPMENTAL CENTER FROM KENT & AUBURN -- EMT 5i 157 \ 900 NO SCAT F or IMP ENG Da DAtt one DEFENSE 1 11R FR ME 9 BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 AREA MAP BLDG. ADDRESS: 9725 E. MARGINAL WAY S. TUKWILA,WASHINGTON er 9 -101 BUILDING LOCATION SAW FA sTssAvo NT NO SCALE SP ❑ AUBURN, WA. ❑EVERETT, WA. O KENT, WA. ❑ PORTLAND, OR. CE GR 98002 98201 98031 97220 C NFERENcr, GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY All DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO TERRY BENNETT AT BLDG. 9 -51 COL N /1, AFTER COMPLETION OF THIS CONSTRUCTION. CHECK BOX PROJECT CHECKLIST IN THESE DRAWINGS CONFORM TO THE 1988 U.B.C., U.F.C., U.P.C., AND THE 1990 BARRIER FREE CODE AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. O ENGINEERING CALCULATIONS ( IF APPLICABLE ) O ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 33 -A. ® BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: O 1. GENERAL PERMIT (SHELL & CORE) 6 SETS OF ENERGY CALCULATIONS 2 SETS OF CIVIL DRAWINGS WITH UTILITIES 2 SETS SOILS REPORTS, STAMPED BY GEOTECHNICAL ENGINEER 2 SETS STRUCTURAL CALCULATIONS 2 SETS PROJECT CONSTRUCTION SPECIFICATIONS 2 SETS TOPOGRAPHICAL SURVEY 2 COPIES OF LEGAL DESCRIPTION 2 SETS OF WORKING DRAWINGS ® 2. TENANT IMPROVEMENTS, 2 COMPLETE SETS ❑ 3. MECHANICAL, 2 COMPLETE SETS ❑ 4. FIRE PROTECTION /SPRINKLERS, 2 COMPLETE SETS • BRIEF PROJECT NARRATIVE INSTALL A NEW EXHAUST FAN TO PROVIDE GENERAL VENTILATION OF A RELOCATED OVEN. rh qq 0 1 35 LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING CROSS TUNNEL FIRST FLOOR MEZZANINE BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC ZONE CODE SUMMARY TUKWILA 1988 UBC, WASHINGTON STATE ENERGY CODE, WASHINGTON STATE BARRIER FREE CODE AND ADDITIONS PER CITY OF TUKWILA GROUP B, DIVISION 2, OFFICE & FACTORY TYPE II, NON - COMBUSTIBLE SEPARATION 60 FEET (MINIMUM ALL SIDES) 713,829 1,116,306 50,910 713,829 55,689 295,878 111 FT. MAXIMUM 2 NO CHANGES I mederstnd Ent T1n Pica C~- • Pact to errors end omiulora : cf /Yno don not gal a its i4MiIiom ci ANON sab M oe111lta F i M contain 99 9: 1 9 fr e palpi agiader Osls, 9 — ,G � romil PIN REVISIONS NO CHANGES SHALL TIE MADE TO THE SCOPE OF WORK WITHOUT PRIOR APPROVAL OP TUKWILA MOO nON. Sans NOM eon So MOM A MOP woun ll ns Iw NO V MOITIO N wig. CITY APPROVED ITRIVATA SEP 1994 „ BUILDS arertiltfau AIM 9 01994 m arna DIVISION BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT 3 PILE COPY B/ AM PERMIT REQUIRED r rot ,: O PLUMBING 0 am PIPING CITY OF TUKWILA MILMO DIVISION ACCEPTAMUTY nit otsa. a*j/OI1 ltQai'wl H AM110K0 Af'ROVED h I Ot01. I DAMS MIN e. o.a CHESIDIntio ocean 111011. J t —J .=J OM S AW ya not TITLE SHEET A d /'s1 1 1 err- -re II % A I A• a Oft •w l ber tAff RYl t I I'iM I DAM; Al TUBEAXIAL FAN RATED TO 2000 CFM 111.75' ESP W/A 5 HP 460 V, PREMIUM 1 EFFICIENCY MDTOR T EAXIAL FAN RATED TO 400 CFM • ESP W/A 1 HP 460 V. PREMIUM E ICIENCY MDTOR 'P X 14'• ECCENTRIC TRANS. 12 ' SPOOL PIECE IP EN� TO T DUCT FROM QVEN EJ3_ _ �@ICIEN� ar 24E71011 r I (•)16i•M (•)1 ` L M Skirl f/ INNS 62/24 15 DUCT 48.0 0. EL. 60/241(9000 CFM RETURN) 45/247 40/24 1M11 111632 20'0 DUCT 68.0.0. EL. 112'— 41 a di ` 50 /I• - � 1 23 N is dir 1 �I 23/20 32/20 AHU 15 20,000CFM PLAN — HVAC DUCT CE) 2250CfM A/C g 'TAME' SIZE 41 20,000CFM 61 SP. 2311, 480V 2 2 : 2 2250CFM IS'S TO AI4• 8 rA�TMENT t nfl q4m In - -- - QlA_IQ090GFs1 20' NECK DIFFUSER Igi 1425 CFM (TYP IS PLCS) SECURITY BARS SEE ONO. 83-€ C — � PLAN WALE: WE - r -0' WZ:rm ® r I;D rimm S D= I>® CIE ONO • • • DEB 13m lit OKI CEO CID 1)D ED 1.0 DD • • • Mane BLDG. 9 -101.1 S - 2' WIDE X II GA LOOP HANGER GENERAL NOTES; I. AIR HANDLING UNIT SUPPLY DUCTWORK TO BE INSULATED 2. EXISTING AIR KINDLING UNITS NC DUCTWORK BEING REUSED WILL BE REPAIRED AND CLEANED BEFOR INSTALLATION 3 PACS HUMID ISTATS FOR CLEAN ROOM EXPANSION AREA LOCATED IN AHU 95 8 /e RA • ASBESTOS NOTIFICATION: A good faith survey of the ark no hoe ban conducted and asbestos containing matwiol was not discovered thot would be involved M Use construction of this project. Do not ram* damage a disturb any • moteriol odjoant to the fork era. Please contort Boeing Fociitil• Ddsplment II osbesta containing motwiol N damaged or discovered shot is required to be removed to support vat The Slowing mated, M the no adjacent to this job ere caused to b• Positiw for abates: FLOOR TILES INSULATION CONSTRUCTION NOTES: FABRICATE AND INSTALL A 3' X 9' TO 6'0 TRANSITION FROM DISCHARGE OF DESPATCH OVEN. THE TRANSITION WILL BE 24" LONG. EXTEND A 14' LONG SECTION OF 6'0 DUCT FROM THE FAN DISCHARGE TRANSITION. © INSTALL A 12'0 X 8'0 X 24' LONG CONCENTRIC RED. AND CONNECT IT TO THE INLET OF THE 8" EXHAUST DUCT. INSTALL THE CONC. REDUCER SO THAT IT OVERLAPS THE 6" X 14' EXTENSION OF THE OVEN FAN DISCHARGE BY 6' (SEE SECTION 'A', SHEET M532) EXTEND THE 8'0 DUCT TO A B.O.D. EL. OF 14' -4' AFF AND ROUTE THE DUCT THROUGH THE NORTH WALL OF THE CLEAN ROOM. , ROUTE THE 8'0 DUCT ALONG THE TRANSPORTATION AISLE 1 014'- 0' AFF. SUPPORT THE DUCT WORK AT MAXIMUM 10' INTERVALS. THE DUCT WILL BE SUPPORTED WITH II GA GCU FRABRICATED LOOP HANGERS (SEE DETAIL 91, SHEET M532). SEAL ALL TRANSVERSE SEAMS. DROP THE DUCT TO A 8.0.0. EL. OF 12'- 4' TO MATCH THE DUCT RUN OF THE EXISTING 15'0 AND 20'0 EXH. DUCTS FROM THE IFF ANTENA AREA. © OFFSET THE 8'0 WITH 45' ELLS'TO RAISE THE 8.0.0. EL. TO IB' 8" THE WILL BE AT THE SAME LOCATION AS THE EXIST. EXH. DUCTS. PROVIDE SUPPORTS AT EACH SET OF ELLS. FABRICATE AND INSTALL AN 8'0 X 14'0 ECCENTRIC TRANSITION. THE TRANSITION WILL BE 24' LONG. CONNECT THE TRANSITION TO THE INLET OF THE FAN VIA A 24' SPOOL PIECE. REPEAT THIS ASSEMBLY ON THE DISCHARGE OF THE FAN WITH THE TRANSITION LOCATING THE 8" DUCT CLOSE TO THE EXISTING 18'0 DUCT. INSTALL THE NEW YORK BLOWER MODEL X112 TUBEAXIAL FAN AS PER THE STRUCTURAL SKETCH j)SK728940525. EXTEND THE DUCT THROUGH THE N. WALL OF THE 9 -101 INTO THE 9 -103 BLDG BETWEEN THE COLUMN AND ELECT. CONDUIT. INSTALL A FIRE DAMPER IN DUCT AT THE WALL PENETRATION BETWEEN THE 9 -101 & 9-103 BLDG. PROVIDE A DAMPER ACCESS DOOR ON THE 9 -101 BLDG. SIDE W /6' HIGH RED LETTERS ON READING 'FIRE DAMPER ACCESS.' EXTEND THE 8" DUCT THROUGH THE 9-103 BLDG. AS A SINGLE CONTINOUSLY WELDED SECT. SO THAT FUMES CAN NOT BE INTRODUCED TO THE CONTROL ROOM OF THE 9 BLDG. THIS SECTION WILL EXTEND FROM THE FIRE DAMPER THROUGH TO THE ROOF PENETRATION. KEEP THE DUCT TIGHT TO THE WALL TO MAINTAIN CLEARANCE BETWEEN THE SWITCH GEAR AS WAS DONE WITH THE TWO EXIST. DUCT RUNS THROUGH THE BLDG.PROVIOE A 20'0 THIMBLE IN THE ROOF FOR THE 5'0 DUCT TO PASS THROUGH THE ROOF STRUCTURE. THE THIMBLE MUST EXTEND 6' ABOVE AND BELOW THE ROOF STRUCTURE. TERMINATE THE DUCT 10' ABOVE THE ROOF WITH A 90' ♦ ELL WITH BIRD SCREEN. COY OF APPROVED SEP 9 5 1M AIM 31 IN Far 6ti n