HomeMy WebLinkAbout2014 - Inspection Notice and Order Prohibiting Occupancy - Lewin Richard / Lewin Marcela - 20140603000440 Return Address: II I 11 11 1111 1111 11 II II II II II CITY CLERK CITY So OF TU 20140603000440 6200 Southcenter Blvd.enter CITY OF TUKWIL N—RER 75.00 Tukwila,WA 98188 PAGE-001 OF 004 06/03/2014 10:49 KING COUNTY, WA Please print or type information WASHINGTON STATE RECORDER'S Cover Sheet (RCW 65.04) Document Title(s)(or transactions contained therein):(all areas applicable to your document must be filled in) 1. Inspection Notice 2. Order Prohibiting Occupancy 3. 4. Reference Number(s) of Documents assigned or released: Additional reference#'s on page of document Grantor(s) Exactly as name(s)appear on document 1 City of Tukwila 2. Additional names on page of document. Grantee(s) Exactly as name(s)appear on document 1. Richard and Marcela Lewin 2. Additional names on page of document. Legal description(abbreviated: i.e. lot,block,plat or section,township,range) Lots 6 and 7, BLK 4, Robbins Spring Brook ADD,VOL 16/57, King County,Washington Additional legal is on page of document. Assessor's Property Tax Parcel/Account Number El Assessor Tax#not yet assigned .7 35 9/o 00 3245 The Auditor/Recorder will rely on the information provided on this form. The staff will not read the document to verify the accuracy or completeness of the indexing information provided herein. "I am signing below and paying an additional$50 recording fee(as provided in RCW 36.18.010 and referred to as an emergency nonstandard document),because this document does not meet margin and formatting requirements.Furthermore,I hereby understand that the recording process may cover up or otherwise obscure some part of the text of the original document as a result of this request." Signature of Requesting Party Note to submitter:Do not sign above nor pay additional$50 fee if the document meets margin/formatting requirements City of Tukwila 6300 Southcenter Blvd., Suite 100 Tukwila,WA 98188 INSPECTION NOTICE 12840 33RD Place S.,Tukwila,WA 98168 RFA12-248 On May 6,2014 The City of Tukwila inspected the structure and documented the following conditions: James Dunaway,Building Inspector documented: Based on records and our inspection today I can identify that there have been three additions to the original structure,without permits. Addition 1:the back of the original home has a two story addition enlarging the main floor living area above,and enlarging the basement living area below. Addition 2:is a one story addition to expand the kitchen. Addition 3: is the largest addition on the end of the home,2 stories,adding a Master Bedroom and Bath up,and a Mother Law apartment down. All though all the additions are finished on the inside it is obvious to me that none of the additions were built to code a may not be structurally sound. Barring walls may have been removed;footings and foundations were not built,or not built to code.Walls and floors in areas are not level or plum and most likely are under framed. Standard construction practices were most likely not applied to any of the additions. The only way to determine the full extent of the framing problems associated with the three additions would be to open up walls and ceilings in key locations,at a minimal. It does appear as though all three of the additions are within set back requirements.We measured the most recent addition to the kitchen,and determined it is within a five foot,side yard,setback, via the neighbor's survived string line. In addition,to the three additions,a 2 story deck was built on the back of the home that is under framed without proper footings,and/or connections to the house,and is in dangerous condition. The deck is adjacent to a slope and could collapse down the slope. Jim Benner, Senior Electrical Inspector documented: • -Exterior lights on the house where observed to be wired without back/splice boxes constituting potential fire hazard. • -Splices to wiring on upper deck without junction boxes pose potential fire/electrocution hazard. • -Dry location wiring and devices observed under the deck.This is a wet location and the wiring is subject to deterioration resulting in potential electrocution hazard. • -Both kitchens were observed to be wired without GFCI protection for counter appliance receptacles posing electrocution hazard. • -100 amp sub panel located in basement.This panel's feeder conductors are not run in a conduit for their entire length.This condition subjects the conductors to potential for mechanical damage which may result in fire or electrocution.Also,no equipment ground to sub panel which may pose electrocution hazard. • -Missing device plates observed throughout the house pose potential fire/electrocution hazard. • -The main panel appears to have been installed without permit. All of these conditions were observed on the visible surfaces of the structure.There is no way to determine the workmanship of the wiring installation within the walls without removing wall and/or ceiling finishes down to the framing.The only acceptable means of verifying the integrity of the wiring and its insulation within the walls and ceilings would be to have a licensed electrician conduct a megger test on all wiring that is not exposed for visible inspection. 1 i • • N1LA, ` •:'tiJ y • ORD "ROB IT • i 1406 s A12248 • Pursuant to Itefrnational>'roperty l!taintcnance Cade Violet ons iOS I.i 108 1', 0$j 108.8 STRUCTURE S .�F OR occ1Y .104C lOB L1 [Tnsafe'stru0 011;000s. • : Irk IOS i.3- Structuteunfitforhuman accUpancy • . 'iPMt 10$ .- Dangerous atructuire+ d'.premises - r.. •IPMC 1-083 • Prohibited occupancy address • 12 0 3 rd Place S.• Tukwila, VGA ' $ f t shy u w for nn e>so7E.to„ cu f fis,stru*wture aft�e�1Via �, 0 4 e st for the u. :se`of fur' the structure,`> akin a top*es re ,airs removin =•ate• - 'hazatdous condition or ot=dembhsb thesame.. :. Tukwila Muw070Veod4G diancef , Nft $:45:0$ - Date May 201 • Bq Order ot: iila . D lattment oif`Comniuuiwt+ eioptnent • $uflldit► Sa etty D vision - 4.1747t-4-€14V.80-46$ oar Dts�tri+ Mv»Tn NOTE WAR1Vi1VG Iiiaalnrawial t$•ifi ow tee Eaioieto lyWi b1be th�'g'O tl&W ecl go8mdkr W a 41.1111A4opG fist ' Etch." 3s1a11I+ca�Yy h a s'a�one"far�.Peuslij it fo th6; t,}v 41a5 ODTo the ud�:of inedawre.ara mu ng� vloliru$,an A�fl IAkall h su. segue roiafib4n prO a same.,_„_„Spi,,,NOitiom u U 4$+I�kcy�l6,Wjt �o+Pale