HomeMy WebLinkAboutPermit 0613 - Southcentert Mall - The Wild PairkDDRESS
633 Southcenter Shopping Seattle, Wa. 98188
PHONE
Ch. 6 -7400
JAME OF BUILDER
Algene Construction Co.
STATE LICENSE NO. 223 -01 -10646
SALES TAX NoC- 600 - 005181
\DDRESS
11323 Lake City Way Seattle, Wa. 98125
PHONE
363 -0303
INSPECTION RECORD
°OOTINGS
BUILDING
PERMIT
VOID IF WORK IS NOT
COMMENCED IN 120 DAYS
12/20/74
ESTIMATED VALUE
COMPLETED WORK $ 24,400.00
FOUNDATION
PERMIT FEE $ 112.00
FRAMING
PLAN CHECK FEE $ 72.80
LATE PERMIT FEE $
TOTAL FEE d $ 184.80
TYPE OF
CONST. IV —N
OCCUPANCY
GROUP F -2
DATE ISSUED
5 / /
ZONE I
USE
ZONE C—M G
xW DATE
FINAL
FIRE SPRINKL
REQUIRED
MAX.
OCC. LOAD
Yes 1111
OCATION OF WORK / NUMBER & STREET
.OT
)WNER
CITY O . TUKWILA BUILDING DEPARTMENT
6230 Southcenter Blvd.
Tukwila, Washington 98067
Phone: (206) 242 -2177
DESCRIPTION OF WORK:
658 Southcenter Mall
SUBDIVISION
BLOCK
Southcenter Corporation
New retail store in existing space.
(The Wild Pair)
THIS PERMIT DOES NOT AUTHORIZE ANY WORK IN PUBLIC RIGHT•OF•WAV OR ON UTILITY EASEMENTS.
SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING.
I HEREBY CERTIFY THAT NO WORK IS TO BE DONE EXCEPT AS DESCRIBED ABOVE AND IN APPROVED PLANS AND
SPECIFICATIONS AND THAT ALL WORK IS TO CONFORM TO TUKWILA CODES AND ORDINANCES.
04-44.A Zo
CALL FOR INSPECTION
BEFORE WORK IS CONCEALED OR
POURING CONCRETE
PHONE
242 -2177
FINAL INSPECTION BEFORE OCCUPANCY
APPLICANT
BY
SUBJECT TO COMPLIANG ITH THE ORDINA
INFORMATION F :E HER WITH, THIS PERMIT I
\y",d=*Awilel
BUILDING DIRECTOR
BY
PERMIT NUMBER
No 613
HE CITY OF,JJiKMhFtfk'tkIVD
A ED.
1CATION OF WORKi STREET
,j R `t• //f G e , , lev << ti .�►
)T
DDRESS
BLOCK
NNER
i r. U arivcroc r XX. Cv __
AME OF BUILDER
e
DDRESS
CITY or AKWILA BWILDIN6 DEP Rr ENT 6 /3
6230 Southcenter Blvd.
Tukwila, Washington 98067
Phone: (206) 242 -2177
SUBDIVISION
0 I9 .S`/ /' a r. 6 G .7 C n
E
i
APPLICATION
FOR
BUILDING PERMIT
ESCRIPTION OF WORK: ,4//e
APPLICANT
DATE ISSUED
EXPIRATION DATE
hr- ' / ci l'. >ir
PHONE
awsiw +
STATE LICENSE NO.2 ,73_ e
SALES TAX NO. C 6 c.' e i'..f /,5
PHONE
e) 3e-')
ESTIMATED VALUE
COMPLETED WORK $ /1 ' s' ‘
PERMIT FEE
PLAN CHECK FEE
LATE PERMIT FEE
TOTAL FEE ?Gle.
TYPE OF
CONST.V5 A
FIRE vv�
ZONE
FIRE SPRINKLE
REQUIRED lib Yw DN°
r •► I►w►� - w.w.- .... .��; �' ✓ �r f �r�i�rl�
$ /17 ,222-
$ 72
THIS PERMIT DOES NOT AUTHORIZE ANY WORK IN PUBLIC RIGHT•OF•WAY OR ON UTILITY EASEMENTS.
■ SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING.
OCCUPANCY
GROUP f
USE • A
ZONE
MAX.
OCC. LOAD
(HEREBY CERTIFY THAT NO WORK IS TO BE DONE EXCEPT AS DESCRIBED ABOVE AND IN APPROVED PLANS AND
SPECIFICATIONS AND THAT ALL WORK IS TO CONFORM TO TUKWILA CODES AND ORDINANCES.
Mr. Barney Ruppert
Blinding Department
City of Tukwila
JH:vma
cc:TFD file
�
FIRE DEPARTMENT
CITY of TUKWILA
444 ANDOVER PARK EAST
TUKWILA, WASHINGTON 98188
TELEPHONE: (206) 244.7221
Fire Prevention Bureau
December 19, 1974
Re: The Wild Pair
(Southcenter)
Dear Barney:
In reviewing the above mentioned project plans, please note
the following items:
1. Per UFC Sec. 10.104(b), "All doors in or leading
to exits shall be maintained openable from the
inside without the use of a key or any special
knowledge or effort at all times when the build-
-ing or area served thereby is occupied ". (Includes
the rear service- door.)
2. Walls to be fire stopped per UBC Sec. 2517(f).
3. All modifications to sprinkler systems shall
have the written approval of the Washington Survey
& Rating Bureau, then of the Tukwila Fire Dept.
No work shall commence without the approved
drawings.
Fire extinguisher type, quantity and placement
shall be per NFPA #10.
ALL wood is to be treated to be fire - retardant.
6. All gypsum wallboard is to be Type "X ".
7. Storage may not be closer than 1$ inches below
sprinkler heads. Please keep in mind when design-
ing & installing storage shelves.
The rolling - grille as shown is not acceptable.
The areas above the suspended ceilings in South -
center are not protected by sprinklers. Therefore,
the rolling - grille may not penetrate the ceiling
unless it is "boxed -in" by one -hour fire- resistive
construction to isolate it from the above - ceiling
area. The alternative to this requirement is to
provide full sprinkler protection above the ceiling.
Please include these comments in your review of the above mentioned
project plans.
James Hoel,Fire Marshal
floor plan
section a-a
wild pair
approved
general notes
section
riser diagram
electrical floor plan
duct work plumbing