Loading...
HomeMy WebLinkAboutPermit EL07-006 - PANERA BREADPANERA BREAD 17250 SOUTHCENTER PY EL07 -006 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: JENNIFER SCHULZ Address: 10230 NE POINTS DR STE 300 , HIRKLAND WA Contractor: Name: SOUTHGATE ELECTRIC INC Address: 23444 30 AV S STE 101 , KENT WA Contractor License No: SOUTHEI366P1 DESCRIPTION OF WORK: NEW BAKERY /CAFE WITH KITCHEN, BAKERY SERVICE, RESTROOMS, AND DINING AREA. Value of Electrical: $80,000.00 Type of Fire Protection: SPRINKLERS Electrical Service provided by: PSE Permit Center Authorized Signature( I hereby certify that I have read an Print Name: doc: EL -4/07 Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2623049117 17250 SOUTHCENTER PY TUKW WIG PROPERTIES LLC -SS 4811 134 PL SE , BELLEVUE WA / lc xzczr ELECTRICAL PERMIT PANERA BREAD BAKERY 17250 SOUTHCENTER PY, SUITE 152 , TUKWILA WA governing this work will be complie • th, whether specified herein or not. Permit Number: EL07 -006 Issue Date: 07/10/2007 Permit Expires On: 01/06/2008 Phone: Phone: 425 827 -2100 Phone: Expiration Date: 08/30/2007 Fees Collected: National Electrical Code Edition: $1,577.50 2005 Date: 1/D 101' ed this permit and know the same to be true and correct. All provisions of law and ordinances The granting of this permit does not • res e to give authority to violate or cancel the provisions of any other state or loc laws regulating construction or the pe ce - I am authorized to sign and obtain this electrical permit. Signature: Date: o7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. EL07 -006 Printed: 07 -10 -2007 Parcel No.: 2623049117 Address: Suite No: Tenant: 1: ** *ELECTRICAL * ** Signature: doc: Cond -Elec City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17250 SOUTHCENTER PY TUKW PANERA BREAD BAKERY PERMIT CONDITIONS Print Name: ■/ /S A9C A/CV Date: Permit Number: Status: Applied Date: Issue Date: EL07 -006 ISSUED 04/03/2007 07 /10/2007 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give}uthority to violate or cancel the provision of any other work or local laws regulating construction or the performance ork. EL07 -006 Printed: 07 -10 -2007 04-03-'07 1Z: bb rtiU[7- publicworxs /aca Mailing Address: Community Developmer. epartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Company Name: — 1 . " - ."6 ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: nem° soonicerne2. ?Alt-r-VaPH Tenant Name: Epp Property Owners Name: V i j ?ge?.0LT1£S 1 M0 W W1 C� Mailing Address: 'iP Vt V5 '1 1 S t. 'tin • : ¢,�u' .f �.. : �sp �. -.:. . „ y, .(� b ri a •.,:`� i > i1Sl +1J' ve ` .3 >r o li, 9n, .. Cif �� �.•: ' UT ,t • P r thit n ;1 : l a �U�,`;' W '' q_ ::5:::� • • � r, tit �^ .: ':,. , ??�,�b .. � i; ti .:z:'^ . _ 4r i ; � i.:; 1.0, :•!% ? '• 1F. -•' 4 } ::ti. i ^�r:r. ... . • ...•�':.�.:4•.:4 +:vii..:.'. •'k -•i + -r r_a:i r: ...,. {.. .... r_: i. i.T.a..,...:: �•..... .i:... . � {!:::. ... A:•m .._:"::L: :!.:•: Name: 31yNN1F 'e• SCktU11- F £1.11V C U W) FgCVEK,_IS Day Telephone: 42.5 - 4321' 210Q Mailing Address: Iat�b •6 TO viewe SIF. an K1 i o WPr X033 Stara Zip E -Mail Address: ‘ )S01-1-012, (' FO Pc12rk . C $rte city Contact Person: _ . Day Telephone: E -Mail Address: Fax Number. Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ F50 Scope of Work (please provide detailed information): isteN t I lz`1 C4WE WVTOr ICXIC1'V£1J i 'BSI l. MICE 1 aSTI2COMS ? TA1 feiZePs Will service be altered? ❑ Yes l,. No Adding more than 50 amps? 0 Yes No Type of Use: ' f. T JR. 't ST Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel Ig Tenant Improvement ❑ Low Voltage ❑ Generator Q Fire Alarm 0 Telecommunication ❑ Temporary Service Property Served by: Puget Sound Energy ❑ Seattle City Light MAApplicationaWarma•Appliaaiana On Linet4 1007 • EhWrical Ponnit Application.doc 1 ron4/00'1 r -Aoo LIODL LjDD� [ Eie ctt'itarPe `' King Co Assessor's Tax No.: Z(j230M q111 Suite Number: 220 Floor: I New Tenant: .... Yes [] ..No teavue city W1k State City Pax Number: ' 878'0611 State C erin Tap Zip Page 1 of 2 104-143 1Z:55 rtiurl puIlicworxs /aca ,. 4 '"r1 W RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) D Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $ I0.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) O Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) Signature: I Date Application Accepted: 641 I Date Application Expires: HAAppliwtiom anus- AppHoltions Or, Lin/AA-2007 - tkotrial remit Apelfation.doc LI004013000 1 — 1 r IU 1 11)1242/ erU2 i Luo MDLT' \MU,Y AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ID Temporary service (residential) 558.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) El Carnivals $75.00 Number of concessions $10.00 ea � • ry ;,�,`*• Nii �- r,/!�•nyi7�ii S II �:�iC��E� �'•.�:�ti;� ! � n,lr Ca c �•� , y� �;! ; i.: r u•' - ��Ii Value of Construction - In all Cues, a value of construction amount should be entered by the applicant This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I FIEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Day Telephone: 'I2b 821 ' 2100 Print Name Mailing Address: 107,5e) NE 'pbINTS ' S1 ?pt7 K 1 1, ItiS� `� City State Zip Date: A -3 -01 Staff Initials: Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049117 Permit Number: EL07 -006 Address: 17250 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 04/03/2007 Applicant: PANERA BREAD BAKERY Issue Date: Receipt No.: R07 -01336 Payment Amount: $1,304.20 Initials: JEM Payment Date: 07/10/2007 03:07 PM User ID: 1165 Balance: $0.00 Payee: SOUTHGATE ELECTRIC INCORPORATED RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 59776 1,304.20 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 ELECTRICAL PLAN - NONRES 000.345.832.00.0 1,262.00 42.20 Total: $1,304.20 0176 07/11 9710 TOTAL 1304.20 rinr.: Rer. int -Q6 Printer: 07 -10 -2007 Doc: RECSEIS -08 RECEIPT NO: R07 -00493 Initials: JEM User ID: 1165 SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description City ui Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payee: FREIHEIT AND HO ARCHITECTS INC., PS SET RECEIPT SET ID: S000000718 SET NAME: Tmp set/Initialized Activities D07 -122 891.01 EL07 -006 273.30 M07 -065 193.60 PG07 -083 99.50 TOTAL: 1,457.41 TRANSACTION LIST: Type Method Description Amount Payment Check 18281 ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES TOTAL: Payment Date: 04/03/2007 Total Payment: 1,457.41 1,457.41 1,457.41 Account Code Current Pmts 000.345.832.00.0 273.30 000/345.830 1,184.11 TOTAL: 1,457.41 P 1044 r4; ‘WC--4A sRectibnr Type of In r ldress: A /7.1Z2 Sew ctArgit MNY Date Called: Special Instructions: Date Wanted: / 717 p.m. Requester: Phone No: "7- INSPECTION RECORD Retain a copy with permit I 4 06 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 (206)431-60 OMMENTS: ()X - t proved per applicable codes. Corrections required prior to approval. lInspnri . .4/11/4/4 IDateW 7 El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: COMMENTS: A.91 Type of Inspection: 0 / -0r /NCI -- /4, / cF /F) q - 5 1/ /416 / w 9 5 Date Called: V c o C uw,v TM. c Special Instructions: Date Wanted: 5/l, a.m. p.m. Requester: Phone No: C /A1 -- /79 / W. .� &kJrs - ifYkrss6A P ( l A � n n , ` d A /` ( !7 Type of Inspection: \ r �•/ Address: ) "7; rr) lif 1 7<--fAITV kk Date Called: V Special Instructions: Date Wanted: 5/l, a.m. p.m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3,6 proved per applicable codes. 6rrections required prior to approval. Insppr 4L y� a5 �ui Date: 9/ 7 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Pr lbwrm 4t4 A K O Type of Inspection: &--S l/ \J Address: / >7 SO SOG/ ri/6 / y Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit P 'MIT O. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 6 dpproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: C / - c_1 z/ S/Tht" $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: Type of Ins ection: Address: 1 -)2-370 ,c011 k Date Called: Special Instructions: Date Wanted: a Requester: Phone No: (L07— 006, INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3(7 INSPECTION RECORD Retain a copy with permit OMMENTS Pfr g- X c // 774c 1. / /1T /i(1 - roved per applicable codes. ❑ Corrections required prior to approval. 71: litff4ky,/‘# El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: 'Date: Pr ct: PA MA .WM6 tf1Xfb/ `Type of Inspection: lo p Z v Address: 0 ?71 / 1 Al Date Called: Special Instructions: Date Wanted: c0 e // a.m -- Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PER CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 OMMENTS: (oX - 90-on- roved per applicable codes. El Corrections required prior to approval. IInspe 'lq LG 71 fi�l�lriff ( $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: Date: Pr ject: Type of Inspection: ` Address: 7V) 5, ViciAliF / Date Called: _._. Special Instructions: Date Wanted: 7 7 . Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISI ON 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERM ' NO. ( 0. 431 -367 proved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: ()/ - 60z(- c__01/4 Inspe `_;tt ! ,fpcx(11iwt/6H I D Xe /p / El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: ...__- s * _ __ 1 , �_ 3_+', t� r...�s_sZr_r�i: Project: (/'/M,4 £ "t-.4 Type of Inspectie / � Address: ,� j - 7 , \ - 0 Car, T1/fF -/"► Lry�/ Date Called: special Instructions: Date Wanted: /� f / a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Inspe Ri 0 U PERM ( 06)431 -3670 pproved per applicable codes. Corrections required prior to approval. COMMENTS: "G /7 /1 d/cA /-r- /'- f fr6rn ' ,i /I Date: 7 b $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: ��tri` :�� �= mss* -�._.. �•' ACTIVITY NUMBER: EL07 - 006 DATE: 04 -03 -07 PROJECT NAME: PANERA BREAD SITE ADDRESS: 17250 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: f5p. > 4- Bui Division Public Works Complete Comments: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP n Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: ❑ Permit Coordinator DUE DATE: 04-05-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required DATE: DUE DATE: 05-03-07 Not Approved (attach comments) n DATE: Planning Division C C Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License SOUTHEI366P1 Licensee Name SOUTHGATE ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 578089488 Ind. Ins. Account Id Business Type CORPORATION Address 1 23444 30TH AVE S STE 101 Address 2 City KENT County KING State WA Zip 98032 Phone 2062441570 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 10/21/1964 Expiration Date 8/30/2007 Suspend Date Separation Date Parent Company Previous License Next License Associated License BRENNPJ066RC Business Owner Information Name Role Effective Date Expiration Date STEIGERS, HERBERT C 01/01/1980 PASCHOS, CHRIS 01/01/1980 PSACHOS, CHRIS AGENT 01/01/1980 PSACHOS, BARBARA SECRETARY 01/01/1980 08/03/2001 Look Up a Contractor, Electrician or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Electrical Administrator Information License Name Status BRENNPJ066RC BRENNAN, PATRICK JOSEPH ACTIVE Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= SOUTHEI366P1 07/10/2007 ELECTRICAL ROUGH -INS MARK ITEM NAME V PH A ROUGH-IN DEV. Of ICE MACHINE 120/208 1 14 0 72' AFF Q Os CIO C W W W ON ROOF [}� O/ ICE MACHINE 120/208 1 7.5 0 72' AFF 120 ® BOTTLE SOFINER 120 1 4 O 15' AFF O O HOT WATER DISPENSER 120 1 4.3 N CASEWORK O 0 OISHWASHER 120 1 12 0 66' AFF m O CASH REGISTER 120 1 5 IN CASEWORK/ 0 46' AFF ROUTE CONDUIT 80.0W FLOOR TO NEAREST WAIL Y41101 ENGAGES CEILNG. O PRIMER 120 f 1 2 IN / Q O FAX MACHNE 120 1 4 046' AFF 0 O MONITOR 120 1 4 IN CASEWORK/ O CREDIT CARD READER 120 1 2 0 IN A C A / AFF OX CARBONATOR PUMP 120 1 10 0 2C AFF 0 O PROOFER 208 3 21 0 108' AFF DI O PROOFER UCH1NG 120 1 15 0 108' AFF Q O TAT SLICER 120 1 9.8 048' AFF 0 O+ DOUBLE RACK OVEN 208 3 7 096' AFF DI 0 OVEN CONTROLS 120 1 5 096' AFF O BREAD SLICER 120 1 6.5 0 24' AFF 0 Iw1 SANDYIICH PREP-TOP 72' 120 1 8.5 0 24' AFF 0 O SODA/ICE DISPENSER 120 1 4 0 72' AFF 0 O UNDER-COUNTER REFRIGERATOR 120 1 4.5 O 24' AFF 0 O UNDER- IER COUNR ORA 120 i 4 O IN gEtoildx 0 UNDER-COUNTER 120 1 4.5 0 24' AFF O TEA BREWER 120 1 15 0 24' AFF 0 O COFFEE MAKER 120/208 3 32 046' AFF Q O ESPRESSO gWl0ER 120 1 2.5 N CASEWORK 0 O r ESPRESSO MACHINE 208 1 21.2 N CASEWORK O MICROWAVE 120 1 12 O 24' AFF 0 ® SOUP STATION 208 1 12.5 0 15' AFF 4 O SOUP STATION 208 1 16.7 015' AFF 41 O SOUP RETHFlODUZER 208 3 16.7 012' AFF 41 0 GLASS DISPLAY CASE 120 1 11.5 IN CASEWORK O COOLER COMPRESSOR • • • • ON ROOF a O COOLER EVAPORATOR • • • O COOLER CLG -o • • • •ON ROOF a ® COOLER EV APORA TOR ' • • 0 COOLER CLG O FREEZER COMPRESSOR • • • • ON ROOF Di O FREEZER EVAPORATOR • • • . FREEZER CL O HOLDING CARNET 120 1 19.1 0 24' AFF ob OZ CONVEYOR TOASTER 120/208 1 21.1 0 24" AFF Eb 0 120 1 5.5 0 24' AFF 0 0 GE 120 • 1 3.3 N CASEWORK 0 O SALAD PREP 120 1 10 O 24' AFF 0 O BAGEL SLICER 120 1 6 0 24' AFF 0 O BLENDER 120 1 11.6 N CASEWORK 0 O SANDWICH TOASTER 120/208 1 15.6 0 24' AFF 40 O HEATED SHELF 120 1 208 N CAS(WORIC O O DECK OVEN - DECK 208" 3 22 SHEET NA 41 O DECK OVEN - FAN 208" 3 6 SHEEP E5.1 4 , 0 TIIEfR TOASTER 120 1 .1 0 24' AFF 0 Of INSECT LIGHT 120 1 .65 O 84' AFF Q AIR CURTAIN 120 1 10 090' AFF ELECTRICAL ROUGH -INS (SEE SHEET E2.2) MARK ITEM NAME V PH A ROUGH -1N DEV. REMARKS a O RECEPTAO ES 1 20 1 20 015' AFF Q TAMPER RESISTANT DUPLEX RECEPTACLE - PASS do SEYMIOUR LEGRAND CATALOG NO 1R63- -COLOR BLACK O RECEPTACLES 120 1 R I cR R gi 0 42' AFF Gil RECEPTACLES O RECEPTACLES 120 1 II 24* NY N 1IAiF -1yML ROUTE CONDUIT BELOW FLOOR TO NEAREST WALL WNW ENGAGES CEILNG. Qi RECEPTACLES 120 1 BASE OF BOOTH ROUTE %IRE RISK BOOTH TO HALF -WALL. THEN RUN CONDUIT BELOW FLOOR TO NEAREST WALL EXTENONG TO CLANG O E RECEPTACLES 120 1 0 37 ' AFF TAMPER RESISTANT DUPLEX RECEPTACLE - PASS & SEYMOUR LEGRAND CATALOG NO. 1R63-COLOR BLACK 000 RECEPTACLES 120 1 a O 3 CFI RECEPTACLES RECEPTACLES 120 1 ROUTE CONDUIT 80.0W FLOOR TO NEAREST WAIL Y41101 ENGAGES CEILNG. HEAT TAPE 120 1 FOR FREEZER CONDENSATE LNE Q WATER RH HEATER 120 1 4 PLATFORM Q PROVIDE ROUGH-IN AND FINAL CONNECTION. SCHEDULE: ROUGH -IN SYMBOLS Q DUPLEX RECEPTACLE G.F.L DUPLEX RECEPTACLE ISOLATED GROUND DUPLEX RECEPTACLE (HUBBELL IG539201 - ORANGE OR EQUAL) Q JUNCTION BOX DISCONNECT WATCH it HEAVY DUTY RECEPTACLE - VERIFY NEMA CONFIGURA11ON - ROUGH -W FOR TELEPHONE VOICE UHE UNLESS NOTED O IHERMISE D :gr FOR 1ELEPHON( DATA UNE OR DATACOM UNLE NO £RMHSE % 4 • w - ELECTRICAL SUPPLY FOR REMOTE CONDENSER SUPPLED FROM ICE MAILER X - CARBONATOR PUMP & SODA DISPENSER SHARE SAME RECEPTACLE Y - CONTRACTOR VERIFY CONNECTION DEVICE VIM EQUIPMENT MANUFACTURER 2 - NEMA 16-30R RECEPTACLE + PROVIDE /10 MIRE PER MANUFACTURER • VERIFY •• DECK OVEN AVAILABLE N 480V FOR PROJECTS WHERE 480N IS WIJZID I LE MADR E VARRIES STORE TO STORE. VERIFY SPECIFICATIONS MOTH CUT # VERIFY REQUIREMENT OF EQUPMENT MOTH LOCATION. olo -Dx SEE SHEET E4.1 FOR ROUGH -IN REQUIREMENTS AT OFFICE. r = L T M27020\27020 E2.1.dwg, 3/30/2007 10:17:50 AM, Adobe PDF • r. D enr. cs shall be made to the scope c T : :: without prior approval cf v.13 require a new plan sutlhnttal c. m :y in dude additional plan review fees. • i PILE COPY Permit No. � 00 6 Plan review cr :rcval Is subject to e u is and ion" Approval Cr cc:h uction documents , , not authorize the violation cf cny accepted code Receipt of approved ri:::; Co c. ` , , . . 1 Is acknowledge* SCALE: 1/4 aty Wogs BUILDING OMSION ELECRICAL ROUGH -IN PLAN • NOTE: THERE ARE MANY CHOICES OF EQUIPMENT FOR FRANCHISEES TO CHOOSE FROM. EQUIPMENT SPECIFICATIONS SHOULD BE VERIFIED WITH ARCHITECT SUPPLIED EQUIPMENT SCHEDULE. ) I rd iiiiiiiiii / iiiiiiiiiiiiiiii//siiii/iii.WM, lien// iii / hill //iifiiiiiiiiiiiiiriiiiiiiii v l r� , r,, /I� vifiiiiiriiiiiiii .►iiiiiiiiriiiiiirii /iiiiiiiiiiiiiiiiiiii /ii/ii/iiiiiiiii/iiiiiii /i/iiii /iri / /ii /iiirims r f: ;r; .• :: : � o f %/ rzmz//////m//mm/ ///////// //////I / ////mA////// /zIMA//// ///mm///// / zd////// zz zem,/ ////// /! //////!!/di/ //e//. • • 7// I//we ez/////////// I/////// I/ I////////////// /////I// / /I/I/ / / / / / //// /I/ ∎:elf //////// ////////// /I///// /I / / //////// // %mm.. w l//!// IAWM:////// 1///// /////// /// / //////// //// / /IZI.Wr ' 1 ■ 1 • � ri i 1 i i 1 = 6 ' - 4J le :�. ► I I 0 I I i 1 I I I I I I I I NORTH • :._:. _ .:- FCJS! i_L •J1 ::2=:.•. = ._ v�. ' -1 : M t zlr 5/4142 EI Afh tolls • awes 1.2• A r:''c T - -, - -, 4- -- 'We SITE COPY BAKERY CAFE: #1215 plolgg UP 7006.04 Q u) 0 V I WV ZI- W = Wrd � jams 8/10/07 l A o esi ISSUE DATE: 2 -16-OT PROW NUMBER: A06 -506 ',DOSSER PROJECT: IT27020 OES LINED BY: OK Sit GNG a Ecxe) BY AVA . SHEET NO: E2.1 KITCHEN EQUIPMENT POWER PLAN I ELECTRICAL ROUGH -INS MARK ` ITEM NAME V PH A ROUGH -IN DEV., 0 O/ ICE mama 120/208 1 14 0 72' AFF O/ � CONDENSER W W W ON ROOF EP go KE wow 120/208 1 7.5 0 72' AFF O BOTTLE SOFTNER 120 1 4 O 15' AFF 0 O HOT WATER DISPENSER 120 1 4.3 IN CASEWORK _ O DISHWASHER 120 1 12 O 66' AFF 0 ® CASH REGISTER 120 1 1 5 2 0 SENUORKJ 0 4 � 6' K/ 4` O CREDIT CARD READER 120 O FAX MACHINE 120 1 4 0 46' AFF 0 0 ' MONITOR 120 1 4 0 46 . / OX CARBONATOR PUMP 120 1 10 0 24' AFF 0 O PROOFER 208 3 21 0 108' AFF Di O PROOFER LIGHTING 120 1 15 0 108' AFF 0 O MEAT SLICER 120 1 9.8 O 48' AFF O O+ DOUBLE RACK OVEN 208 3 7 O 96' AFF UP O OVEN CONTROLS 120 1 5 O 96' AFF 0 O BREAD SLIER 120 1 6.5 O 24' AFF 0 O ) PREP-TOP 120 1 as O 24' AFF 0 OX SODA/ICE DISPENSER 120 1 4 O 72' AFF 0 Q T 120 1 4.5 0 24' AFF 0 O UNDER- COUNTER REFRIGERATOR 120 1 4 O g IN O COUNTER 120 1 4.5 , 0 24' ALT 0 O TEA BREWER 120 1 15 0 24' AFF 9 O COFFEE MAKER 120/208 3 32 0 46' AFF 0 O ESPRESSO GRINDER 120 1 2.5 W CASEWORK 0 OY ESPRESSO MACHINE 208 1 21.2 W CASEWORK 4) 0 MICROWAVE 120 1 12 0 24' AFF 0 O SOUP STATION 208 1 12.5 0 15' AFF 4) O SOUP STATION 208 1 16.7 0 15' AFF 4) O SOUP RE1HERMAUZER 208 3 16.7 0 12' AFF 4 O GLASS DISPLAY CASE 120 1 11.5 IN CASEWORK 0 O COOLER COMPRESSOR • • • • ON ROOF Di ® COOLER EVAPORATOR • * • O COOLER aG 0 O COMPRESSOR • s • • ON ROOF Di O MESii DOUGH EVAPORATOR • * • O COOLER aG 0 On FREEZER COLOR • s • • ON ROOF UP O FREEZER EVAPORATOR s = • 0 FREEZER CEG 0 O HOLDING CABINET 120 1 19.1 O 24' AFT 4) OZ CONVEYOR TOASTER 120/208 1 21.1 • 24' AFF 4) O COLD BEVERAGE DISPENSER 120 1 5.5 0 24' AFF 0 O 120 1 3.3 N CASEWORK 0 , O SALAD PREP 120 1 10 O 24' AFF 0 O BAGEL sum 120 1 6 0 24' AFF 0 O BLENDER 120 1 11.6 N CASE# RTC_ 0 O SANDWICH TOASTER 120/208 1 15.6 0 24' AfF 4 O HEATED SHELF 120 1 2.06 N CASEWORK 0 O DECK OWN - DEOK 208" 3 fl SHEET 4) O DECK OVEN - FAN 208" 3 _ 6 4 S` O TIMER 120 120 1 .1 0 24' AFF 0 INSECT LIGHT 120 1 .6S 084' AFF 0 Q - AIR CURTAIN I 120 1 10 O 90 AFF W - ELECTRICAL SUPPLY FOR REMOTE CONDENSER SUPPLED FROM ICE MAKER X - CARBONATOR PULP & SODA DISPENSER SHARE SAME RECEPTACLE Y - CONTRACTOR WRIFY CONNECTION DEVICE 111TH EQUIPMENT MAMFACIINIER 2 - NEMA L6-30R RECEPTACLE + PROVIDE 110 1MUE PER MAMIFACIIII:ER VERfY is DECK OWN A10111J4BLE N 480V FOR PROJECTS WHERE 4801/ IS UMUED I ICE MAMIE YARES STORE TO STOREE, VERIFY SPEOF1CATIOKS WADI GUT SHEETS If VERIFY REQUIREMENT OF EQUIPMENT VAIN LOCATION. NOTE: DERE ARE MANY CHOICES OF EGUPMEIIT FOR FRANCHISEES TO CHOOSE FROM. Emma SPECIFICATIONS SHOULD 8E VEINED 111111 ARCHTECT SUPPLIED EQUIPMENT SCI DIRE. I SEE ONE -UNE DIAGRAM AND PANEL SCHEDULES ON SHEET E4. PROVIDE ROUGH -IN AND FINAL CONNECTION TO ROOFTOP UNIT. ROOFTOP UNIT - MOUNTED DISCONNECTING MEANS SUPPLIED BY EQUIPMENT MANUFACTURER. MAKE FINAL CONNECTION TO WIT-MOUNTED WEATHERPROOF Gil SERVICE RECEPTACLE PROVIDED BY EQUIPMENT MANUFACTURER. PROVIDE SEPARATE STEP -DOWN TRANSFORMER CONNECTED AHEAD OF EQUIPMENT DISCONNECTING MEANS TO SUPPLY 120 - VOLT, SINGLE-PHASE POWER TO RECEPTACLE. RECEPTACLE SHALL NOT BE CONNECTED TO THE LOAD SIDE OF EQUIPMENT DISCONNECTING MEANS. SEE NEC ARTICLE 210.63. COORDINATE WITH MECHANICAL CONTRACTOR AND EQUIPMENT MANUFACTURER. SEE DETAILS ON SHEET E4.1 FOR LOCATION AND CIRCUIT OF RECEPTACLES IN OFFICE AREA. ALL WRING TO DEVICES IN FRONT COUNTER SHALL BE RUN IN CABINETRY OR IN CASING. RUN CONDUIT BELOW SLAB TO NEAREST WALL WHICH ENGAGES CEILING FOR CIRCUITING 'HOME RUNS'. EACH ISOLATED GROUND CIRCUIT SHALL BE RUN IN SEPARATE CONDUIT. ROUTING OF CONDUIT BELOW FLOOR SHALL BE IN SUCH A WAY AS TO MINIWZE CHANNEUNG OF SLAB AND AMOUNT OF CONDUIT. RECEPTACLES FOR EQUIPMENT NOS.: 53A, 55C, AND 64 ON THE FRONT UNE) SHALL BE FLUSH - MOUNTED AND RECESSED INTO CASEWORK. PROVIDE ROUGH -IN AND FINAL CONNECTION TO RACK OVEN HOOD EXHAUST FAN, DRAFT INDUCER MOTOR, AND PRESSURE SWITCH. FAN SHALL BE INTERLOCKED 11TH OVEN TO RUN WHEN OVEN IS ON. FAN POWER TO BE FED FROM OVEN CONTROL aRCUIT. SEE WIRING DETNLS ON MECHANICAL SHEETS. COORDINATE WITH MECHANICAL CONTRACTOR AND EQUIPMENT MANUFACTURER. PROVIDE ROUGH -IN AND FINAL CONNECTION TO MAKE -UP AIR UNIT ON ROOF. UMT SHALL BE INTERLOCKED WITH RACK OVEN AND RACK OVEN HOOD EXHAUST FAN TO RUN WHEN OVEN IS ON. SEE WIRING DETAILS ON MECHANICAL SHEETS. PROVIDE WEATHERPROOF CFI SERVICE RECEPTACLE. RECEPTACLE SHALL NOT BE CONNECTED TO THE LOAD SIDE OF EQUIPMENT DISCONNECTING MEANS. SEE NEC ARTICLE 210.63. COORDINATE WITH MECHANICAL CONTRACTOR. PROVIDE X10 AWG ME FOR RACK OVEN POWER PER MANUFACTURER REQUIREMENTS. %I. ►i �.e. wed eArz.�� /�� /��zem.r,ze/��� .rze� ��.emzzrze# zgs.���fz���r���ze,z �zezoze��iie��z�����i������zezzrz�z # #. /ze���z/rte././.// r 097 /./ ii,WIZZLIZeZKiiiiiir. VAZI ,. fir iZIZA/Armzirem,,,,,IZIZZ. . K/ 17,## M. iiitiitiiiiiiiiiizemziiii77.4e, .W.ggedw/ �/% 1/ 11 } :1 . 11 . 1:111 : : :11; c 1 CPI PANEL SSAGE WOMENS FREE +24' IGP -27 CARBONATOR PUMP (CORD CONNECTED) ATION DINING RM BEVE 1 AKERY ERVICE +15' CAFE FLOOR RECEPTACLE. PLACE IN FRONT OF WINE CASEWORK. COORDINATE WITH FIXTURE CONTRACTOR SERVICE K1 -21 '415 i /;ft IGP -22,24 KITCH SMART RM IT . it ti 1I11.1 +1� +15' +ti+ +15' ate= = l / 5_= _- ?_f/,"= =LQe -1 II) II I III! I I ItUI ll[II I( IIIIIIII[IIIII{i111I1 III jU t • • .... / / / / / / /// i : .` rill.,ir,f7mziiAgowliiiii mzz, 4 iiiiiiMAKAIZZez iiizeLe iiiiiirze.ezz zeze.iiiiiiym.Arrrz iiwwi rdwe jj ozone i. zzeze iim.m.ii -v### zzArArzommzezed i • • rii iii ✓iiiiiii rrii .e.ezz/.I//.// m ze LAKezz•///ordzez ze ize ,we//////eym.r/ /I / //!// /I //// // % ## F . •'YJZ# /I /'I. l /.T.� / /,ezzoz / .wAr//// ///Y //////ize.r / // /.% i i i [+ CAI ► 15 `1 [ . +15 K2- 13,15,17 D O L' c KEYED NOTES: PROVIDE ROUGH -IN AND FINAL CONNECTION TO COFFEE MACHINE. PROVIDE 'LOCK -Our TAPE CIRCUIT BREAKER IN PANEL M. PROVIDE ROUGH -IN AND FINAL CONNECTION FOR DECK OWN. COORDINATE ELECTRICAL CONNECTION DETAILS YAM OVEN SUPPLER. COORDINATE LOCATION OF QUICK - DISCONNECTS WITH OWNER REPRESENTATIVE IN FIELD. PROVIDE EXCESS CABLE TO ALLOW OVEN TO BE PULLED OUT 2. -6' MINIMUM FOR CLEANING. SEE DETAIL ON SHEET E8. PROVIDE ROUGH -IN AND ANAL CONNECTION TO COOLER / FREEZER COMPRESSOR. COORDINATE WITH G.C. AND COOLER/ FREEZER MANUFACTURER. PROVIDE ROUGH -IN AND FINAL CONNECTION TO COOLER/ FREEZER DOOR. FIELD VERIFY LOCATION. COORDINATE WITH G.C. AND COOLER/FREEZER MANUFACTURER. 101 -2 IGP -6 K1 -26 K1 -26 ELECTRICAL POWER PLAN SCALE: 1/4' = 1-O RECEPTACLE FOR ESPRESSO MACHINE PROVIDED BY MANUFACTURER. MOUNT ESPRESSO RECEPTACLE SIDEWAYS IN CASEWORK CHASE SO CORD AND PLUG DOES NOT INTERFERE WITH REFRIGERATOR LOCATION. PROVIDE ROUGH -IN AND FINAL CONNECTION TO SANDWICH TOASTER. REPLACE MANUFACTURER PROVIDED CORD AND PLUG WITH NEMA 6 -30P RIGHT -ANGLE PLUG (FLAT 'DRYER -flPE' PLUG) - SIMILAR TO AMERICAN INSULATED WIRE PART NO. A0933006GY OR EQUAL RECEPTACLE TO BE MOUNTED WITH GROUND SLEEVE UP. PROVIDE ROUGH -IN AND FINAL CONNECTION TO DISHWASHER HOOD FAN. FAN TO BE CONTROLLED NA 'ON -OFF' SNATCH. COORDINATE LOCATION OF SWITCH 11TH G.C. IN FIELD. COORDINATE HOOD CONNECTION WITH MECHANICAL CONTRACTOR. ELECTRICAL CONTRACTOR TO MAKE ELECTRICAL CONNECTION BETWEEN ICE MAKER AND REMOTE CONDENSER. COORDINATE 11TH G.C. AND EQUIPMENT MANUFACTURER. PROVIDE ROUGH -IN AND FINAL CONNECTION TO FIREPLACE IGNITION CONTROL SWITCH. FIELD VERIFY LOCATION. COORDINATE 11T11 OWNER AND FIREPLACE MANUFACTURER. NORTH r GENERAL NOTES: 1.b1 1) E.C. SHALL RUN NEUTRAL AND GROUNDING WIRES TO ALL KITCHEN EQUIPMENT. 2) ALL KITCHEN EQUIPMENT SHALL BE FURNISHED BY OTHERS. ELECTRICAL CONTRACTOR SHALL SET IN PLACE AND MAKE FINAL CONNECTIONS. 3) ALL CONDUIT PASSING THROUGH WALL OF COOLER/FREEZER SHALL BE SEALED WITH SILICONE. 4) ALL RECEPTACLES SHALL BE NEMA GROUNDING TYPE. RECEPTACLES IN DINING AREA SHALL HAVE BLACK WIRING DEVICES AND BLACK COVERS. RECEPTACLES IN KITCHEN AREA SHALL HAVE BLACK WRING DEVICES AND BRUSHED STAINLESS STEEL COVERS. 5) ALL KITCHEN EQUIPMENT JUNCTION BOXES SHOWN SHALL INCLUDE ANAL CONNECTION TO THEIR RESPECTIVE KITCHEN EQUIPMENT. 6) VERIFY ELECTRICAL REQUIREMENTS, CONNECTIONS, AND EXACT LOCATION OF CONNECTIONS. COORDINATE YAM EQUIPMENT SUPPUER /CONTRACTOR. REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC APR 13 2007 • City Of Tukwila a BUDDING DIVISION - -I- [ GFa I +24' t f ' I 3 r- u : • N:\27020 \27020 E2.2.dwg, 3/30/2007 10:18:46 AM, Adobe PDF • • • • • BAKERY CAFE: #1215 1�O : ua .RA ti i 1 I DIMES 8/10/07 I ISSUE DATE: 2 -16.01 PROJECT NUIMEIEFt A06 -506 ABOSSEIN PROJECT: !27620 DESIGNED 8Y: De. $14. GP D BY: AVA SHEET NO: E2.2 ELECTFCCAL POWER PLAN ELECTRICAL ROUGH -INS MARK ITEM NAME V PH A ROUGH -IN DEV. O/ ICE MACHINE 120/208 1 14 0 72' AFF CD Di � _ W W W ON ROOF Cji Of , moo ICE MACHINE 120/208 1 7.5 0 72' AFF Q ® 8OTTLE SOFINER 120 1 4 015' AFF 0 O HOT WATER DISPENSER 120 1 4.3 N CASEWORK 0 0 i DISHWASHER I 120 1 12 066' AFF 0 O CASH REGISTER 120 1 5 O CASEWORK/ a O CREDIT CARD READER 120 1 2 O �/ O FAX MACHINE 120 1 4 O 46' AFF 9 O MONITOR 120 1 4 0 CASEWORK/ 46. AFF 9 OX CARBONATOR PUMP 120 1 10 0 24' AFF I 0 O PROOFER 208 3 21 O 108" AFF DJ O PROOFER UGHTNG 120 1 15 0 108' AFF Q ® MEAT SLICER 120 1 9.8 0 48' AFF 0 0 DOUBLE RACK OVEN 208 3 7 096' AFF D O OWN CONTROLS 120 1 5 0 96' AFT 0 O BREAD SLICER 120 1 6.5 0 24' AFF 0 O SAND#a1 PREP -TOP 7 ?' 120 1 8.5 0 24' AFF 0 OX SODA/ICE DISPENSER 120 1 4 0 72' AFF 0 O UNDER-CITRIER 120 1 4.5 0 24' AFF 0 O -CTOR � ORA 120 1 4 O c 2 4 4;474 N 0 O RFFR UNDER-COUATER 120 1 4.5 0 24' AFF 0 O TEA BREWER 120 1 15 0 24' AFF 0 ® COFFEE MAKER 120/208 3 32 0 46' AFF Q O ESPRESSO CRUDER 120 1 2.5 IN CASEWORK 0 OY ESPRESSO MACHINE 208 1 21.2 IN CASEWORK do O MICROWAVE 120 1 12 0 24' AFF 0 ® SOUP STATION 208 1 12.5 0 15' AFF 4) O SOUP STATION 208 1 16.7 015' AFF 4) O SOUP RETHERMAUZER 208 3 16.7 0 12 Aff 4 0_ GLASS DISPLAY CASE 120 1 11.5 N CASEWORK 0 O COOLER COMPRESSOR . s s $ ON ROOF Er O COOLER EVAPORATOR s • s 0 COOLER CLG 0 O COOLER • * * * ON ROOF D I . O 009EE EVAPORATOR s s s 0 COOLER CLG O FREEZER COMPRESSOR s s s s ON ROOF 01 O FREEZER EVAPORATOR s s s 0 FREEZER CLG co ® HOLDING CARNET 120 1 19.1 0 24' AFF 4) OZ CONVEYOR TOASTER 120/208 1 21.1 • 24' AFF 4) O 120 1 5.5 0 24' AFF 0 o 120 1 3.3 N CASEURK 0 O SALAD PREP 120 1 10 0 24' AFF 0 ® BAGEL SLICER 120 1 6 0 24' AFF 0 O BLENDER 120 1 11.6 N CASEWORK 0 O SANDNIC1 TOASTER 120/208 1 15.6 0 24' AFF do O HEATED SEW 120 1 2.08 N CASEWORK 9 0 DECK OWN - DECK 206' 3 22 DETNL e SEES 0 DECK OVEN -FAN 208 3 6 w _ SIM BA O TWFR TOASTER 120 1 .1 • 24' AFF 0 Q - INSECT LIGHT 120 1 .65 0 84' Aff Q AIR CURTAIN , 120 1 10 090' AFF t • W - ELECTRICAL SUPPLY FOR REMOTE CONDENSER SUPPLED FROM ICE MAKER X - CARBONATOR P1W & SOOA DISPENSER SHARE SAME IRECEPTACIE Y - CONTRACTOR WVFY CONNECTION DEICE 1MTH EGIIWIMENT YMRUFAC U RER Z - NEMMA L6-30R RECEPTACLE + PROVIDE .10 NDIE PER UANUFACU ER * VIVIFY * DECK OVEN AMIABLE N 480V FOR PROJECTS MERE 480V IS UIUJAD I ICE MAME WARES STORE 10 STORE, VERIFY SPECIFICATIONS /1H CUT SEERS #1 VERIFY REEQUBREENT OF EQUIPMENT ILIITH LOCATION. NOTE: THERE ARE MARY CHOICES OF EQUIPMENT FOR FMS 10 QOM FROM. EQUIPMENT SPECIFICATIONS SHOULD OE VERIFIED MN ARONTECT SiwPIiFD EQUIPTEMT SCHEDULE — -R- r K1 -28 !GP -27 SEE ONE -UNE DIAGRAM AND PANEL SCHEDULES ON SHEET E4. PROVIDE ROUGH -IN AND FINAL CONNECTION TO ROOFTOP UNIT. ROOFTOP UNIT- MOUNTED DISCONNECTING MEANS SUPPLIED BY EQUIPMENT MANUFACTURER. MAKE FINAL CONNECTION TO UNIT - MOUNTED WEATHERPROOF Gil SERVICE RECEPTACLE PROVIDED BY EQUIPMENT MANUFACTURER. PROVIDE SEPARATE STEP -DOWN TRANSFORMER CONNECTED AHEAD OF EQUIPMENT DISCONNECTING MEANS TO SUPPLY 120 -VOLT, SINGLE -PHASE POWER TO RECEPTACLE. RECEPTACLE SHALL NOT BE CONNECTED TO THE LOAD SIDE OF EQUIPMENT DISCONNECTING MEANS. SEE NEC ARTICLE 210.63. COORDINATE 111H MECHANICAL CONTRACTOR AND EQUIPMENT MANUFACTURER. SEE DETAILS ON SHEET £4.1 FOR LOCATION AND CIRCUIT OF RECEPTACLES IN OFFICE AREA. ALL WIRING TO DEVICES IN FRONT COUNTER SHALL BE RUN IN CABINETRY OR IN CASING. RUN CONDUIT BELOW SLAB TO NEAREST WALL WHICH ENGAGES CEILING FOR CIRCUITING 'HOME RUNS'. EACH ISOLATED GROUND CIRCUIT SHALL BE RUN IN SEPARATE CONDUIT. ROUTING OF CONDUIT BELOW FLOOR SHALL BE IN SUCH A WAY AS TO MINIMIZE CHANNEUNG OF SLAB AND AMOUNT OF CONDUIT. CPI PANEL _L = CFO : +24' K2 -40 RECEPTACLES FOR EQUIPMENT NOS.: 53A, 550, AND 64 ON THE FRONT UNE) SHALL BE FLUSH - MOUNTED AND RECESSED INTO CASEWORK. PROVIDE ROUGH -IN AND FINAL CONNECTION TO RACK OWN HOOD EXHAUST FAN, DRAFT INDUCER MOTOR, AND PRESSURE SWITCH. FAN SHALL BE INTERLOCKED WITH OWN TO RUN WHEN OWN IS ON. FAN POWER TO BE FED FROM OWN CONTROL CIRCUIT. SEE WRING DETALS ON MECHANICAL SHEETS. COORDINATE WITH MECHANICAL CONTRACTOR AND EQUIPMENT MANUFACTURER. PROVIDE ROUGH -IN AND FINAL CONNECTION TO MAKE -UP AIR UNIT ON ROOF. UNIT SHALL BE INTERLOCKED NTH RACK OWN AND RACK OVEN HOOD EXHAUST FAN TO RUN WHEN OWN IS ON. SEE 11RNG DETAILS ON MECHAMCAL SHEETS. PROVIDE WEATHERPROOF CH SERVICE RECEPTACLE. RECEPTACLE SHALL NOT BE CONNECTED TO THE LOAD SIDE OF EQUIPMENT DISCONNECTING MEANS. SEE NEC ARIICE.E 210.63. COORDINATE VIM MECHANICAL CONTRACTOR PROVIDE 110 AWG WRE FOR RACK OVEN POWER PER MANUFACTURER REQUIREMENTS. KEYED NOTES: PROLE ROUGH-11 AND FINAL CONNECTION TO COFFEE MACHINE. PROVIDE "LOCK -OUr TYPE CIRCUIT BREAKER IN PANEL M. PROVIDE ROUGH -IN AND FINAL CONNECTION FOR DECK OWN. COORDINATE ELECTRICAL CONNECTION DETAILS NTH OWN SUPPLiER. COORDINATE LOCATION OF QUICK - DISCONNECTS NTH OWNER REPRESENTATIVE IN FIELD. PROVIDE EXCESS CABLE TO ALLOW OWN TO BE PULLED OUT 2. -6' MINIMUM FOR CLEANING. SEE DETAIL ON SHEET E& PROVIDE ROUGH-IN AND FINAL CONNECTION TO COOLER / FREEZER COMPRESSOR COORDINATE NTH G.C. AND COOLER/ FREEZER MANUFACTURER PROVIDE ROUGH-1N AND FINAL CONNECTION TO COOLER/ FREEZER DOOR. FIELD VERIFY LOCATION. COORDINATE 11TH G.C. AND COOLER/KREEZER MANUFACTURER. / 1 ,.,., ,,,,,,.,, � , % nunnnnuuin Inn uun:j /// // ///A////!////z/////// mArz.,,// I// / / /I/,a//I///IYmw.e///1//I // rm Ar// ll/////// I// I////// // / /I / / ////////!/I/I////, :ew /// w 1 /I /I //i %///////////// ll/ I!/I /I // // / ////I / / // / I////// I✓//// I////J//// I//////. l I///////.// I//// I//// I ///./I /I / ///I/!// / /I///I ////I/ wr. ezmz.r. /////I/I/// //// ////I///i %/! // //. U I // ///I/i % . /T. ' : l//// I// I /I/ll /ll//ll/ll/// ///1 / /I /I /s GFCI el i [i, i // /ra/AIii /I , ..!r•:ri /// /i MENS - 4 WO, N WOMENS SMART RM ",,) SERVICE 200 !J 1 Ali K2 -13,1 7 - - -K1 -34 K1 -22,23 K2 -42 K2- 14,16,18 HOT BEVERA 120 AKERY ERVICE CAFE 110 ii 11 li +46' Kti ,9,�1lIIi161i iillii WNW , 1 111111111111111111 OVEN 1C2- 7,9.11 SODA/ICE DISPOSER CARBONATOR PUMP (CORD CONNECTED) • 1 -22,24 LD 1 • IGP -6 K1 -26 ELECTRICAL POWER PLAN SCALE: 1/4' = 1 RECEPTACLE FOR ESPRESSO MACHINE PROVIDED BY MANUFACTURER. MOUNT ESPRESSO RECEPTACLE SIDEWAYS IN CASEWORK CHASE SO CORD AND PLUG DOES NOT INTERFERE WITH REFRIGERATOR LOCATION. •13 • PROVIDE ROUGH -IN AND FINAL CONNECTION TO SANDWICH TOASTER REPLACE MANUFACTURER PROVIDED CORD AND PLUG NTH NEMA 6 -30P RIGHT -ANGLE PLUG (FLAT 'DRYER -TYPE' PLUG) - SIMILAR TO AMERICAN INSULATED WIRE PART NO. A0933006GY OR EQUAL RECEPTACLE TO BE MOUNTED 11TH GROUND SLEEVE UP. PROVIDE ROUGH -IN AND FINAL CONNECTION TO DISHWASHER HOOD FAN. FAN TO BE CONTROLLED VIA 'ON -OFF' SNITCH. COORDINATE LOCATION OF SNITCH NITH G.C. IN FIELD. COORDINATE HOOD CONNECTION WITH MECHANICAL CONTRACTOR. <> ELECTRICAL CONTRACTOR TO MAKE ELECTRICAL CONNECTION BETWEEN ICE MAKER AND REMOTE CONDENSER. COORDINATE NTH G.C. AND EQUIPMENT MANUFACTURER. K1 -26 J PROVIDE ROUGH-IN AND FINAL CONNECTION TO FIREPLACE IGNITION CONTROL SWAN. FIELD VERIFY LOCATION. COORDINATE 111H OWNER AND FIREPLACE MANUFACTURER. Go +24' NORTH r GENERAL NOTES: 1) E.C. SHALL RUN NEUTRAL AND GROUNDING WIRES TO ALL KITCHEN EQUIPMENT. 2) AU. KITCHEN EQUIPMENT SHALL BE FURNISHED BY OTHERS. ELECTRICAL CONTRACTOR SHALL SET IN PLACE AND MAKE FINAL CONNECTIONS. 3) ALL CONDUIT PASSING THROUGH WALL OF COOLER /FREEZER SHALL BE SEALED WITH SIUCONE. 4) ALL RECEPTACLES SHALL BE NEMA GROUNDING TYPE. RECEPTACLES IN DINING AREA SHALL HAW BLACK WIRING DEVICES AND BLACK COVERS. RECEPTACLES IN KITCHEN AREA SHALL HAVE BLACK WRING DEVICES AND BRUSHED STAINLESS STEEL COVERS. 5) ALL KITCHEN EQUIPMENT JUNCTION BOXES SHOWN SHALL INCLUDE FINAL CONNECTION TO THEIR RESPECTIVE KITCHEN EQUIPMENT. 6) VERIFY ELECTRICAL REQUIREMENT% CONNECTIONS, AND EXACT LOCATION OF CONNECTIONS. COORDINATE WTI EQUIPMENT SUPPUER /cONIRACTOR. 100 • ULE i I i • -- GFC +24' • is 0 ; ; - -- BAKERY CAFE: #1215 SYSTEM: G2(W PROTOTYPEU A POA IDP1N3 8/10/07 to t" N U_ U m ISSUE DATE: 2 -16.07 PROJECT NUMBER: X406 - 506 A60SSEIrI PROJECT- *27020 DESIGNED BY. D8. Sit GNG CHECKED BY: AVA SHEET NO: E2.3 E LECTFOCAL POWEFt PLAN p II d REVISED PER LLD COMMENTS 3/23/07 II KEYED NOTES: COORDINATE CONNECTION OF COOLER/FREEZER LIGHTING 1M1H COOLER/1REEZER EQUIPMENT SUPPUER AND CONTRACTOR. MANUFACTURER PROVIDES FIXTURE, AND CON1RACTOR PROVIDES LOW TEMP BALLAST. SEE SHEET El FOR RECEPTACLE LOCATIONS FOR FLOOR/TABLE LAMP. PROVIDE ROUGH —IN AND FINAL CONNECTION TO RESTROOM EXHAUST FAN — REFER TO MECHANICAL DRAWINGS FOR LOCATION AND REQUIREMENTS. ii • or /// /// iZ7// s o /!! %!%!!!!%!! rt %!%r i !!!! %i!!!iwe.e.Ai�Il! %fArm.!!! %� %% %fir r /!I�M:MMAIN!iilw/IurwLeAr - -eAki iweLirri ezA rmze.r ! % !! %%i%% !!z,e,ge '!! m,,, w#,r ,i!!!r % %!% !!/. � I I 3— CONDUCTOR SWITCH OCT. LP -1 SWITCH a¢ 113 11-6 IT1A i 1 I L=; -- -- 1 1 I % I % 1 I % I V' I tI t I I t I IS tI I 1 It A t n V • l I 1P -14 Y A I t 1% It 1 11 A 1I I ` 1 1 SY T 3—CONDUCTOR 1 1 IT 1 I l 1 1 SWITCH HCKT. TING SWITCH BANK A —H /MAW/ 1 // /�A� i #i PROVIDE JUNCTION BOXES FOR THREE (3) 120V /1PH 20 AMP CIRCUITS FOR SIGNAGE. SIGNAGE CONSISTS OF ONE (1) INDIVIDUALLY LETtERED ` PANERA' SIGN (011E CIRCUIT). ONE (1) INTERNALLY ILLUMINATED BOX SIGN 'BREAD` (ONE CIRCUIT). AND ONE (1) INTERNALLY ILLUMINATED 'MOTHER BREAD LOGO' SIGN (ONE CIRCUIT). SEE ARCHITECTURAL SIGN DRAWINGS. VERIFY ALL DETAILS PRIOR TO ROUGH —IN. PROVIDE 12 —POLE UGHTING CONTACTOR FOR ALL EXTERIOR UGHTNG. CONNECT TO TIME CLOCK ADJACENT TO UGHI1NG PANEL. S%NTCH RACK OVEN HOOD LIGHTING SO THAT LIGHTS IN HOOD CAN BE ON %LIEN KITCHEN LIGHTS ARE OFF. LOCATE SWITCH ON INSIDE OF HOOD WHERE POSSIBLE. WHEN NOT ALLOWED BY LOCAL JURISDICTION LOCATE SWITCH %NTH FIELD INSPECTOR. SWITCH BANK A —H. FIELD VERIFY EXACT LOCATION WITH MANAGER PRIOR TO INSTALLATION. LP-1 16 TO: TIMER j EXT3A • EXT3A 1P -2 a sit. 1 - t , N :127020\27020 E3.1.dwg, 3/30/2007 10:19:28 AM, Adobe PDF LIGHTING GENERAL NOTES INSTALL LIGHT FIXTURES IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND THE LATEST EDITION OF THE NEC. ALL WRING SHALL BE COPPER. #12 THHN STRANDED IN 3/4' CONDUIT UNLESS OTHERWISE NOTED. WHERE CONDUCTORS ARE NOT INDICATED (FOR CLARITY) INSTALL CONDUCTORS AS INDICATED BY THE CORRESPONDING HOMERUN. AU. IXTURES TO BE PROVIDED BY, RECEIVED, STORED, AND INSTALLED BY THE ELECTRICAL CONTRACTOR. ALL FIXTURE LAMPS SHALL BE SUPPLIED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. ALL FIXTURES TO BE CENTERED IN 2x2 MUM TILE. ELECTRICAL CONTRACTOR SHALL SUPPLY 10% MINIMUM ADDITIONAL SPARE LAMPS FOR ALL LAMP TAPES. 'NL' REFERS TO NIGHT LIGHT FIXTURE. NOTE: SEE SHEET A2 FOR LIGHT FIXTURE SCHEDULE AND ADDITIONAL INFORMATION ON FIXTURE LOCATIONS. NOTE: ALL FIXTURES (NO EXCEPTIONS) TO BE OBTAINED THROUGH NATIONAL ACCOUNT AT: CITY UGHTNG PRODUCTS 4307 W. PAPN STREET ST. LOUIS, MO 63110 314- 534 -1090 (CENTRAL STANDARD TIME) PANERA ACCOUNT REPRESENTATIVES — CHRIS OR RUTH SCALE: 1/4' = 1 -0' am . ELECTRICAL LIGHTING PLAN • , BAKERY CAFE: #1215 SYSTEM: G2 ( W PROTOTYPE UPOA ' W= oCi iovas 8/10/07 ISSUE DATE 2 -16.07 PROJECT NUMBER A06 -506 A8OGSEaN PROJECT: 427020 DESIGNED BY: 06. SH. GNG CHECKED BY: AVA 1 SHEET NO: E3.1 11ECTRNC,AL UGNT!►YG PUN • a 4 GENERAL NOTES., 1. UNLESS OTHERWISE NOTED ALL PULL BOXES SHALL BE PROVIDED WITH 3/4' CONDUIT WITH PULL WIRE STUBBED OUT ABOVE ACCESSIBLE CLUNG. 2. ALL J -BOXES 6' ABOVE SHELF OR 6' BELOW DESK TO CEN1ERLNE. CCN (SAWIS) (1) 24' DEEP PEAS LAM WHITE SHELF (CAPABLE OF SUPPORTING 42 IBS) CCTV (SAWIS) (3) 16' DEEP PLAS LAM WHITE SHELVES MOUNTED w/ INDUSTRIAL STRENGTH KV BRACKETS CPU AND CPU N SWITCH AND SAWS O Rk145 JACKS PRINTER GENERAL POWER MONITOR FILE CABINET (SEE EQUIPMENT SCHEDULE) 1'-0'. CAFE BACK OF HOUSE RELAY RACK CONFIGURATION (SEE ENLARGED DETAIL) I MUSIC EQUIPMENT 1109 (SEE EQUIPMENT I SCHEDULE FOR MORE INFORMATION) I SOUND SYSTEM POWER 0 0 WIRE PULL BOX SOUND SYSTEM RAM (SAME UNE AS FAX) FOR MUSIC SYSTEM INTERNET DOWNLOAD. 6 ENLARGED OFFICE WALL ELEVATION PLAN / DETAIL KEYED NOTES: SEE 'PIS SYSTEM DIAGRAM' ON SHEET E4.3 FOR ALL MIIRNG AND CONNECTION INFORMATION. PROPOSED 1E1EPHONE BOARD LOCA1ION. PRO ICE TWO 2' CONDUITS TO ABOVE AIDE CEILING. VERIFY EXACT LOCATION IN FIELD. PROVDE JUNCTION BOX NTH 2' CONDUIT AND 2x2 RING STUBBED UP ABOVE ACCESSIBLE COMIC. PROVE COWER PLATE FOR J-BOL SEE MANAGERS OFFICE DESK DETAIL.. AT FAX MANE PRONE ROUGH-IN FOR PHONE LINE AT 48" AFF NTH 1/2' CONDUIT W/PULLWRE UP N PAR1ITON STUBBED OUT ABOVE ACCESSIBLE CLG. PROVIDE CONDUIT FROM ALL PHONE OUTLETS AT HEIGHT INDICATED TO THE TELEPHONE SYSTEM N THE OFFICE. TELEPHONE CONDUITS SHALL HAW A PULL MARE NSTAUED STUB 3/4' CONDUIT FROM TELEPHONE OUTLET TO ABOVE FINISHED CURE. PROVIDE INSULATED BUSHING ON CONDUIT END. CURVE CONDUIT TOWARDS DIRECTION OF TELEPHONE SERVICE. COORDINATE MT1H TELEPHONE COMPANY PRIOR TO INSTAL ANION. O PROVDE SEPARATE CONDUIT RI1 BELOW FLOOR OR N CASEAORK FOR SOUND SYS 111 WRING TO MICROPHONES - VERIFY REg IROAENTS N FEED O PROVIDE PUSH BUTTON AT MAIN BAKERY REGISTER NTH CLIME N REAR AREA. CHKE TONE SHALL BE DIFFERENT FROM THAT OF THE DOOR ONE RUN WIRING N CABINETRY AND /OR N CONDUIT BELOW FLOOR (F REQU RID) TO STUB OUT ABOVE ACHE CfENG. VERIFY REQUIREMENTS N FIELD. PROVI E DOOR BUZZER SYSTEM AT REAR ENTRY DOOR PROVIDE PUSHBUTTON AT 48' AFF ADJACENT TO SERIE SIDE OF ENTRY DOOR. PROVIDE BUZZER MOUNTED LIST BELOW CLUING N KITCHEN AREA. FEED VERIFY EXACT LOCATION. PUSHBUTTON SHALL 13E LDWA RDS ¢32 OR EQUAL. BUZZER SHALL BE gpWMiDS 725 OR EQUAL PROVIDE ROUGH-RA AND FINAL CONNECTION TO SMOKE DETECTOR MOUNTED IN RETURN AR DUCT. DETECTOR SHOULD SHUT DOW RN UPON ACTIVATION. CONNECT TO FIRE ALARM SYSTEM WI REQUIRED OR VISUAL DEVICE 0 CEILING. VIDEO MONITOR IS SUPPLIED BY VENDOR COMPLETE NTH VDU CONTROLLER BOX CONTROLLER SHALL BE MOUNTED ON SHELF BELOW MONITOR WEN MONITOR 915 ON TABLE, OR N CASEWORK BELOW WHEN MONITOR SITS ON CASEWORK. VERRFY REZUEEMENTS N FIELD PROVIDE SINGLE GANG BOX ROUGH-IN AT T-10 AFT MATH 1/2' CONDUIT W/ PULLIIRE UP N PARTITION STU OED OUT ABOVE ACCESSIBLE Cl1NG FOR OUTDOOR SPEAIO:R MIME CONTROL COORDINATE WORK SUN SOUND PROVIDE ROUGH -N FOR TEMPERATURE SDISOR /ALARM ALARM IS PRO WED AND INSTALLED BY SECURITY SUB - CONTRACTOR WWI REQUIREMENTS WITH SECURITY SUB - COMPACTOR. TYPICAL FOR FRS AND 000LER. PROVIDE ALL NECESSARY CONTROL MINENG FOR FREEZER MD COOLER WRFY REQULREIENTS WTH MANUFACTURER. COORDINATE FOUL PHONE RECEPTACLE LOCATIONS WIN WITH EMINENT CONTRACTOR AND OWNER'S REPRESOffAWE (PER PLAN). s s SCALE: NTS SMART RM SK 4 MAJMSCR'S PC cs C OICKIED CROWD PCS CURETS MANAGER'S OFFICE DESK DETAIL COLD BEVERAGES 15o FOS S CHoss COTON PARR MEL PCS MEW IEiwOWI Hue SINAI S/PCon MD OUCf10) Tr%*1s UPS POSER SUPPLY I 41 tVADON STIIIIIE ilia( CAFE BOH RELAY RACK CONFIGURATION CI I MR PCMWS) l SCALE: NTS 0. PHONE BLOC( _17) SCALE: 1/4" = 1 _� REVIEW C NFPA 7Q - NEC N APR 13 2401 MANAGER'S OFFICE WALL DETAIL O SPECIAL SYSTEMS PLAN O HOT BEVERAGES 120 TO CIRCUIT IGP -29 'OUTPUTS' CAFE 0 01 if , 1 ® SPRINKLER FLOW SWTCH Id 0 SPRINKLER TAMPER SWITCH FIRE ALARM PULL STATION 0 SMOKE DETECTOR AUDIO/ ASUAL ALARM DEVICE NOTE: CONTRACTOR TO SUPPLY AND INSTALL ALL DEVICES AND WIRING. ENTIRE NSTAIIATION SHALL BE N ACCORDANCE WITH LOCAL JURISDICTION REQUIREMENTS FIRE ALARM SYSTEM DIAGRAM SCALE: NTS C kio FIRE MARIA CONTROL PANEL SIMPLEX OR EQUAL CAFE Ito �(•D1.00� C t 1. 40' CONNECT TO TELEPHONE SYSTEM 'INPUTS' Z 0 4 0 2 0 o rrrr�iiiir rriiiiiiiriiiriri rim riiirirr�rri�iiiirrr rr riirr itriiiiiiiiirrirriiiir riiriiiiiiiiiiiriiiiiiiirrfriirriiri rr m#Z- -Z.: ZZZ -iririii�iir ZCZ. r 0ZZ. �iriiiririiiiriiiiiirZZ ;Ziiiirisririiii vi�riiiirrirZ i •r, r r,""5urrr """r ","#ir2""Ori i� rruiiMAWAIIKOWAr irirriirr ./.640iZrri riirri�..441 rzfw etzezrm � earrrii omeArAritrrririiiiii�iiiii m :•:... riArAnrd eezArmAro .rr riiii mr.e 4 rriiiirrrr.�rIM/Zi�IMIZiiAGGIAI i/MAI r /./ZWAIM/ZeZ,W A rrIMAI/iiW.W.adriiirriii G iiriiiiirrii..FIWZ i IMAIO://r/ rrriiiM# SERVICE BAKERY • m o -• 1111 T1 F� rr ; • MENS WOMEN PASSAGE 1 O WOMENS Sae !DATION KITCHEN ERY VICE VESTIBULE i i E I . 1 4 e fAls lel., � J / /r'� / �/ /. i . L— 3 • Q: 1 BAKERY CAFE: #1215 t� T EWE IwwrE aoo A Imam 8/10/07 ISSUE OAT1» 2 -1607 PROJC-CT NUMBER AC6 -506 7.EIN PROJECT: DESIGNED SY: 06. SH, GNG CHEMED SY: AVA SHEET NO: E4.1 SPECIAL SYSTEMS P[AN 17200 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON II U.D REVIEW COMMENTS 2/16/07 II ii L REVISED PER LLD COMMENTS 3/23/07 11 1 1 4 GENERAL NOTES., 1. UNLESS OTHERWISE NOTED ALL PULL BOXES SHALL BE PROVIDED WITH 3/4' CONDUIT WITH PULL WIRE STUBBED OUT ABOVE ACCESSIBLE CLUNG. 2. ALL J -BOXES 6' ABOVE SHELF OR 6' BELOW DESK TO CEN1ERLNE. CCN (SAWIS) (1) 24' DEEP PEAS LAM WHITE SHELF (CAPABLE OF SUPPORTING 42 IBS) CCTV (SAWIS) (3) 16' DEEP PLAS LAM WHITE SHELVES MOUNTED w/ INDUSTRIAL STRENGTH KV BRACKETS CPU AND CPU N SWITCH AND SAWS O Rk145 JACKS PRINTER GENERAL POWER MONITOR FILE CABINET (SEE EQUIPMENT SCHEDULE) 1'-0'. CAFE BACK OF HOUSE RELAY RACK CONFIGURATION (SEE ENLARGED DETAIL) I MUSIC EQUIPMENT 1109 (SEE EQUIPMENT I SCHEDULE FOR MORE INFORMATION) I SOUND SYSTEM POWER 0 0 WIRE PULL BOX SOUND SYSTEM RAM (SAME UNE AS FAX) FOR MUSIC SYSTEM INTERNET DOWNLOAD. 6 ENLARGED OFFICE WALL ELEVATION PLAN / DETAIL KEYED NOTES: SEE 'PIS SYSTEM DIAGRAM' ON SHEET E4.3 FOR ALL MIIRNG AND CONNECTION INFORMATION. PROPOSED 1E1EPHONE BOARD LOCA1ION. PRO ICE TWO 2' CONDUITS TO ABOVE AIDE CEILING. VERIFY EXACT LOCATION IN FIELD. PROVDE JUNCTION BOX NTH 2' CONDUIT AND 2x2 RING STUBBED UP ABOVE ACCESSIBLE COMIC. PROVE COWER PLATE FOR J-BOL SEE MANAGERS OFFICE DESK DETAIL.. AT FAX MANE PRONE ROUGH-IN FOR PHONE LINE AT 48" AFF NTH 1/2' CONDUIT W/PULLWRE UP N PAR1ITON STUBBED OUT ABOVE ACCESSIBLE CLG. PROVIDE CONDUIT FROM ALL PHONE OUTLETS AT HEIGHT INDICATED TO THE TELEPHONE SYSTEM N THE OFFICE. TELEPHONE CONDUITS SHALL HAW A PULL MARE NSTAUED STUB 3/4' CONDUIT FROM TELEPHONE OUTLET TO ABOVE FINISHED CURE. PROVIDE INSULATED BUSHING ON CONDUIT END. CURVE CONDUIT TOWARDS DIRECTION OF TELEPHONE SERVICE. COORDINATE MT1H TELEPHONE COMPANY PRIOR TO INSTAL ANION. O PROVDE SEPARATE CONDUIT RI1 BELOW FLOOR OR N CASEAORK FOR SOUND SYS 111 WRING TO MICROPHONES - VERIFY REg IROAENTS N FEED O PROVIDE PUSH BUTTON AT MAIN BAKERY REGISTER NTH CLIME N REAR AREA. CHKE TONE SHALL BE DIFFERENT FROM THAT OF THE DOOR ONE RUN WIRING N CABINETRY AND /OR N CONDUIT BELOW FLOOR (F REQU RID) TO STUB OUT ABOVE ACHE CfENG. VERIFY REQUIREMENTS N FIELD. PROVI E DOOR BUZZER SYSTEM AT REAR ENTRY DOOR PROVIDE PUSHBUTTON AT 48' AFF ADJACENT TO SERIE SIDE OF ENTRY DOOR. PROVIDE BUZZER MOUNTED LIST BELOW CLUING N KITCHEN AREA. FEED VERIFY EXACT LOCATION. PUSHBUTTON SHALL 13E LDWA RDS ¢32 OR EQUAL. BUZZER SHALL BE gpWMiDS 725 OR EQUAL PROVIDE ROUGH-RA AND FINAL CONNECTION TO SMOKE DETECTOR MOUNTED IN RETURN AR DUCT. DETECTOR SHOULD SHUT DOW RN UPON ACTIVATION. CONNECT TO FIRE ALARM SYSTEM WI REQUIRED OR VISUAL DEVICE 0 CEILING. VIDEO MONITOR IS SUPPLIED BY VENDOR COMPLETE NTH VDU CONTROLLER BOX CONTROLLER SHALL BE MOUNTED ON SHELF BELOW MONITOR WEN MONITOR 915 ON TABLE, OR N CASEWORK BELOW WHEN MONITOR SITS ON CASEWORK. VERRFY REZUEEMENTS N FIELD PROVIDE SINGLE GANG BOX ROUGH-IN AT T-10 AFT MATH 1/2' CONDUIT W/ PULLIIRE UP N PARTITION STU OED OUT ABOVE ACCESSIBLE Cl1NG FOR OUTDOOR SPEAIO:R MIME CONTROL COORDINATE WORK SUN SOUND PROVIDE ROUGH -N FOR TEMPERATURE SDISOR /ALARM ALARM IS PRO WED AND INSTALLED BY SECURITY SUB - CONTRACTOR WWI REQUIREMENTS WITH SECURITY SUB - COMPACTOR. TYPICAL FOR FRS AND 000LER. PROVIDE ALL NECESSARY CONTROL MINENG FOR FREEZER MD COOLER WRFY REQULREIENTS WTH MANUFACTURER. COORDINATE FOUL PHONE RECEPTACLE LOCATIONS WIN WITH EMINENT CONTRACTOR AND OWNER'S REPRESOffAWE (PER PLAN). s s SCALE: NTS SMART RM SK 4 MAJMSCR'S PC cs C OICKIED CROWD PCS CURETS MANAGER'S OFFICE DESK DETAIL COLD BEVERAGES 15o FOS S CHoss COTON PARR MEL PCS MEW IEiwOWI Hue SINAI S/PCon MD OUCf10) Tr%*1s UPS POSER SUPPLY I 41 tVADON STIIIIIE ilia( CAFE BOH RELAY RACK CONFIGURATION CI I MR PCMWS) l SCALE: NTS 0. PHONE BLOC( _17) SCALE: 1/4" = 1 _� REVIEW C NFPA 7Q - NEC N APR 13 2401 MANAGER'S OFFICE WALL DETAIL O SPECIAL SYSTEMS PLAN O HOT BEVERAGES 120 TO CIRCUIT IGP -29 'OUTPUTS' CAFE 0 01 if , 1 ® SPRINKLER FLOW SWTCH Id 0 SPRINKLER TAMPER SWITCH FIRE ALARM PULL STATION 0 SMOKE DETECTOR AUDIO/ ASUAL ALARM DEVICE NOTE: CONTRACTOR TO SUPPLY AND INSTALL ALL DEVICES AND WIRING. ENTIRE NSTAIIATION SHALL BE N ACCORDANCE WITH LOCAL JURISDICTION REQUIREMENTS FIRE ALARM SYSTEM DIAGRAM SCALE: NTS C kio FIRE MARIA CONTROL PANEL SIMPLEX OR EQUAL CAFE Ito �(•D1.00� C t 1. 40' CONNECT TO TELEPHONE SYSTEM 'INPUTS' Z 0 4 0 2 0 o rrrr�iiiir rriiiiiiiriiiriri rim riiirirr�rri�iiiirrr rr riirr itriiiiiiiiirrirriiiir riiriiiiiiiiiiiriiiiiiiirrfriirriiri rr m#Z- -Z.: ZZZ -iririii�iir ZCZ. r 0ZZ. �iriiiririiiiriiiiiirZZ ;Ziiiirisririiii vi�riiiirrirZ i •r, r r,""5urrr """r ","#ir2""Ori i� rruiiMAWAIIKOWAr irirriirr ./.640iZrri riirri�..441 rzfw etzezrm � earrrii omeArAritrrririiiiii�iiiii m :•:... riArAnrd eezArmAro .rr riiii mr.e 4 rriiiirrrr.�rIM/Zi�IMIZiiAGGIAI i/MAI r /./ZWAIM/ZeZ,W A rrIMAI/iiW.W.adriiirriii G iiriiiiirrii..FIWZ i IMAIO://r/ rrriiiM# SERVICE BAKERY • m o -• 1111 T1 F� rr ; • MENS WOMEN PASSAGE 1 O WOMENS Sae !DATION KITCHEN ERY VICE VESTIBULE i i E I . 1 4 e fAls lel., � J / /r'� / �/ /. i . L— 3 • Q: 1 BAKERY CAFE: #1215 t� T EWE IwwrE aoo A Imam 8/10/07 ISSUE OAT1» 2 -1607 PROJC-CT NUMBER AC6 -506 7.EIN PROJECT: DESIGNED SY: 06. SH, GNG CHEMED SY: AVA SHEET NO: E4.1 SPECIAL SYSTEMS P[AN 17200 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON - I I I ,1 , ! I I ' I Iris "4; I ' I r .fia; ' i r ', ■ ! L _ 1 WALL PLATE TYPICAL SEE NOTE NO TES, 11S SHT I1fPKCAI PATCH UNMIXED CAT -5e ETHER NET TYPICAL O PULBOX FOR POS/ IEGISIER WRING CCIV/SA CCTV/SAWS POKER IGP -8 GIFT CARD, AND O CREDIT CARD BACKUP RJI1 MODEM JACK CPU POSER IGP -2 CPU RJ-45 FOR CPU TO HUB ( STITCH) AND CPU TO SAWS CON1ECDON PRINTER GENERAL POSER NP-6 MORTON POSER IGP -2 E4.3 SCALE: NTS CREMT Y C,AN PRIMAR a REGISTER (POS) PC BACK -UP W/EXIRA MODEM EQUIP. #30 D A RJ-1 - I. I 1 TO IEIFIIO ( I t OUTLET'S SEE I 1 PUN FOR LOCABONS USE I I REGISTER (POS) EQUIP. #30 OFFICE CARD MODEM (BACK -UP) OFT CARD iiODEM =WE MODEM AT SERWR EKE SERWR (NESS OTHERWISE NOTED ALL PULL BOXES SHALL BE PROwDED NTH 3/4" CONDUIT N1H PALL WIRE STUBBED OUT ABOVE AcE CEILING` ALL J -BOXES 6 ABOVE S1U.F OR 6" BELOW DESK TO (.1 i DETAIL KEYED NOTES: 40 SEE POS DETAE 1/4.3 DRS 9EET FOR All NRNG NO CONECIION IN FORYAAOIL REUSE css1NG JUNCu0N BODES NO I MIIG MERE POSSIBLE. O P FRODDE 8Jt8tz4 JUUIC70011 BOIL NTH Y CONDUIT NO ltd SWIG SAWED UP ABOVE Ate€ CELNG. PRU)YDE COYER PLATT: FOR (HEX SEE MINUS OFFICE DESK OETHL O FRODDE CONDUIT FROM AIL RICK CURETS AT HOW IDICARD TO 11E TELEPHONE MIN N DE OFF'ACE. sum/ C IWIS SINE HAW A PULL SIRE INSTALLED STUB 3/4' CONDUIT FTLd1 TELEPHONE OUTLET TO ABOW FINISHED CUM PROW MIMED BUSING ON CONDUIT END. CURIE CONDUIT M LOS WECDON OF WIERNOIE SERVICE: COORONATE NTH 1ELEPHO E OOIPNIIY PRIOR 10 NSTALIATIQL a e MN B e MIN A REQSIER (P06) EQUIP. #30 RELAY RACK SOUND SYSTEM POTTIER IGP -6 (15) MUSIC SYSTEM CABINET (14) SPEAKER MIRE PULL BOX SOUND SYSTEM MODEM (SAME LINE AS FAX) O FOR MUSIC SYSTEM INTERNET DO 1LOAD. r OFRCE PHONE Jetac r f ON RIGHT HAM WALL NM DESK PHONE ROCK /- DESKTOP -WRFY HEIGHT f NTH GENERAL CONTRACTOR SECURITY PUSH - BUTTON 2 MANAGER'S OFFICE DESK DETAIL 11 SOUND SYSTEM MOWN SECURITY SYSTEM POSER DUPLEX - OCT. IGP -8 E4.3 SECURITY SYSTEM CONTROLS (12) (13) SCALE: NITS REGISTER (POS) SECUS11Y TIRE I PULL BOX 6 WlER1OR PHONE LINE PULL BOX O PRODDE RECESSED SINGE GANG JUNCTION BOIL BELOW YANAGOG DESK NTH 1/2" CONDUIT HAULM UP N NAVIN SUED OUT ABOVE AOCSHE CRUM FOR ALAN! SYSTEM HOLD -!P PUSHBUTTON. FEID %MY EXACT LOCA1ON •/IOUTNERS REPIESENTAXE. COORS UW SARK NTH SECURITY SYS1E31 CON1RACTOR PROPOSED WHAM BO NO LOCADOL PRE 1110 2' WOWS TO ABOVE ACHE COOK W M E)flUCT IOCA110N N FEID. MODE SINGLE GANG 93X ROUGu-ii AT 7 AFT MI 10 CONDUIT TI/ SULNRE UP N MINION SUM OUT IBM ACCESSIRE MUM roe OUTDOOR SPEAKER 'UU0.UIE CONTROL COMMA WORK 1111N SOUND sue-cantina PHONE SYSTEM POSER DUPLEX - CKT. IGP -8 WALL PUl1E mat PATCH CABLES PHONE SYSTEM B 0 REGIS1ER (POS) PHONE-11 EQUIP. #30 REGISTER (POS) REGISTER (P06) EQUIP. 130 EQUIP. #30 POS SYSTEM D IAG RAM E4.3 SCALE: N.T.S. DEDICATED NU!D POS OUTLETS IGP-20 3 MANAGER'S OFFICE WALL DETAIL E4.3 PATCH CABLE (1) (2) SCALE: NTS PHOIE LSE --4► e PLATER EQUIP. #31 i i l I I� �1 FAX MADRE EQUIP. in POS ONLY SEE OFFICE DETAILS AND NOTES FOR MORE INFORMATION ON OFFICE REQUIREMENTS. PRINTER PATCH UNSHIELDED EVER NET TYPICAL - rTi D■>i rA�►�sTlrs il A • PRIMER EQUIP: #31 e a t EQUIP. #33 4 RELAY RACK DETAIL 11/SAWIS PHONE JACK J BOX e Mann EQUIP P3 = WS) PC (SAWS) PATCH NMI PC PRINTER EQUIP. #31 E4.3 e INN MONITOR EQUIP. #33 TO POS A U - 1= - MONTOR MONITOR EQUIP. i33 EQUIP. #33 WAIL RAE TY e& PATCH CABLES (6) SCALE: NTS HUB (SNITCH) B SAWS 10BASE -T RATE TYPICAL mat PATCH CABLE 5 CABLE SCHEMATIC 2' B PATCH CABLE PRIMER EQUIP. #31 REVIEWED FOR CN NEPA7 0- N EC APR 13 20 Oty OfTu� TIDING � N D-s- CCTV LW IKN TOR IEP-8 • 4'-O' AFF 1. s MANAGER'S OFFICE SIDE WALL DETAIL SCALE: N1S POS SYSTEM NOTES: GC ELECTRICAL CCNRACTOR TO FIIRNSH AND INSTALL ALL POS SYSTEM RACEWAYS, CONDUITS AND JUNCTION BOXES FOR Poe SYSTEM. PANERA TO PRONE UM AND IERMNATIONS` CONTACT: MIDI t A_ MT E A: ANGELA SOORY AT 3t4- 33 -720 FOR cc1PLEit NFORILA110N ON RANG REQUIREMENTS. 2 PROVIDE 1 -1/4' C RAlH TWO UNSHIELDED CATEGORY 5E tiNES FROM EACH CASH REGIS1ER TO EQUIPMENT BOARD N OFFICE ONE CAT -5E IRE FOR THE CASH REGIS MD ONE FOR THE ATTACHED PRINTER. EACH WAIL PLATE TO HAW (2) RJ-45 JACKS (II CASEWORK). ALL UNDERFLOOR CONDUIT MID ROUGH-INS BY EC. FUN CCN mi BELOW FLOOR OR N CASEWORK TO NEAREST FULL IEIGHT PARTITION AS REQUIRED. RUN RANG OONCEMID N CABRE1RY/CASEMIORK. 3. PRONUOE 1• C WITH UNSHIELDED CATEGORY 5E FROM EACH MONITOR CR PRIMER TO EQUIPMENT BOARD N OFFICE EACH WALL PLATE TO HAVE (2) RJ-45 JACKS ON CASEWORK). ALL UNDERFLOOR CONDUIT AND ROUGH -NS BY EC. RUN CONDUIT BELOW FLOOR OR N CASEWOMC TO NEAREST FUL HEIGHT PARTITION AS REQUIRED RUN SIRING CONCEALED N CABNEIRY CASEYIORIG 4. THE LAST REGISTER RA1H N TIE REGISTER LOOP SHALL BE THE PHONE -N STAIN. (EX. F THERE ARE 8 REGISTERS, AE 8th ONE MU. BE THE PHONE -fl STATION. F 7 RESISTERS, 7th ONE SHALL BE IRE PHONE-IN STATION.) 5. IRE PHONE LIE TO CASEWORK FOR CREDIT CARD CONNECTION SHALL BE NSTAWD N 1 CONDUIT TO ALLOW FOR FUTURE CAPACITY IF AD0111ow PHONE LIES ARE REQUIRED. 6, P06 DMA LIES SHALL BE INSTALLED N OOFDUIT SEPARATE FROM ALL POTS CONDUCTORS 7, CONIUNICATKINS CONTRACTOR MUST TEST ALL FEEDS FOR CONINIMY AND LABEL ALL FEEDS a ALL ROUGH-NS FOR EQUIPMENT 0 CASEWCIN TO BE FRONDED N FRONT RACEWAY OF CASEWORK. ALL ROUGH-INS FOR EQUU MDIT DI REAR SOME LSE TO BE 016• AFF !NESS OITERNLSE NOTED OFFICE CABLING NOTES POS SYSTEM (1) ALL DATA DROPS FOR REGISTERS & PRINTERS SRL CONNECT INTO TIE PATCH PANEL 1HR000H THE 8X8X4 JUNCTION BOX SEE KE1fED NOTE NUMBER 2 AND POS SYSTEM DIAGRAM AND NOTES (2) ONE CABLE GOES FROM THE STTCH TO ME PATCH PANEL (3) ONE CABLE GOES FROM MANAGERS PC RJ45 10 STITCH (LOCATED TO THE LEFT OF 1FE RACK) (4) ONE CABLE Is CONNECTED N DE MANAGER'S PC TO THE JACK LOCATED BY THE PC NARKED 'S'rI TCH' ON THE OFFICE LAYOUT. (5) NETKORK SNITCH TAIL BE POICIED BY TIE UPS (NIGH 1S PLUGGED INTO THE OUTLET BELOW SAWS ROUTER (6) MANAGER'S PC MIL CONNECT TO THE RJ45 JACK DIRECTLY BESIDE IT N (7) AT THE RACK THE SAWS ROWER SILL CONNECT TO THE T1/PCON, THE MANAGER'S PC & CCTV (ALL LOCATED TO lilt RIGHT OF THE RACK) (8) DE SAWS ROWER WLL BE POISED BY THE UPS BELOW IT. CCTV (9) INKS TILL BE LOCATED AT THE TOP LEFT AREA. (10) THE TINT TILL CONNECT TO THE POOR & RJ-45 JACK NOTED ''SALTS' (U) FLAT PANEL MONITOR Nu. BE HUNG ADJACENT WALL TO OE*, JUST IN FRONT OF DE SHELVING. ALARM SYSTEM (12) DRS ONCE CAN BE LOCATED AWMERE N THE *TICE THE CONiECHON IS A CATS LARNE HARMED INTO TIE PHONE SYSTEM AND A POSER OUTLET. (13) F STORES ARE PRE -TOES, THE TECH MAY LEAW THE Lilt AT THE PHONE AREA TO PUNCH ON1 NTO TIE SYSTDL OMX/MUZAK (14) LOOMED N THE RIGHT HAND SCE SHELF MIL BE 1( WIGHT AND BE HEED lair TOWING. (15) CONNECTION IS A PHONE Lilt INTO THE RJ-11 JACK PROVIDED & POSER PLUS NI AUDIO JACK RUN OVER THE PHONE SYSiifM AND MIMED N (THE PHONE SYSTEM HAS DIE JACK ALREADY EXISNIlG. SEE THE P06 DIAGRAM INS SHEET. 1,0T-00to 0.: - J N:\27020\27020 E4.3.dwg, 3/30/2007 10:21:00 AM, Adobe PDF • • BAKERY CAFE: #1215 SYSTM: G2 (WARM= PROTOTEYPE UPOA1 E WV i IMMO W= looms 8/1 0/07 ISSUE DATE: 24647 PROJECT NUMBER A06-506 ABOSSErN PRO.ECT: 127020 DESKGNED SY: D6. SH, GIG CHECKED BY: AVA ) SHEET NO: i E4.3 POS SYSTEM DI GRAM AND NOTES • PANEL IMP goer /12w eoa wD (NEC SDI oisO i NECT INK 0 0 0 0 400A :0 ■ • - r— ' , 0 0 • rr ol VI $ 0 0 z m Z m ♦4 tnIr d1 z I i lib i 5 eti 2 a Al ; WirR 81 114 GOA Iw> 1 11 O 4 > P • M CZ> > • n w> r:_: A w> n w> n w s n a> r. w> n a> nos :.; n w> n w> n w> n w> n w> n w> n w >1 • 2 V i r. i > > r r r w r r e r . s i s i> Y :n to 1 2 I nto ;e w s n e I N isiwwiswstiving I ._ > n Iq> n w> n w> RiCiA r; 0 • a btd re pp s 0 M • 0 1 n O> n a> A w 111 45 N Cio•A ;:.: sat caat6 va1„" a M . ‚iii'.'." ��en9 1 I 11111111 II�NIO o • I' • n w > n w > n a> n w> n a> n aone.* >::::A w> A w> n w> A w> A w> A w i n a> 31 • 0 zsss z a a ii ::: 's e ` ��� °3 F M • a as 3 x • 0 0 S Ic� � 1 Icy; .I 4tttn:Filj w 2 le tDOlm BAKERY CAFE #1215 SOUTHCENTER SQUARE 17200 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON i ~ n m I w • A a> A w> A a> A w> A w> A a> 1 OIM 1 a 3 2 4 b 1! • >>>>>>>> t2 2! 3E Ci; J O .+ O N 44444 • • drl • v w '� I 1 ig 6 A EIZON O O O A 0 e e sligA I a C2 0 w r 2 ° N 0 N ;.t a c e s «N. $ 'i X a z a. .« .. e r a C a r RIB n w> n a> A a> n a> n w> n a> A w> •:.A w> A a> A w> A O> A O> n a i n w n a> A w> A a> A w> A w> n a> A O b. A w> A O> A w> n a> n O> A a> n w> a a a a 14 a fa a • a ro a • • 3 Zst FREIHEIT & HO ARCHITECTS, INC., P.S. 1010111501141 IORINO•VIMINS ROIND.210) 1441511110, a F t p ;11114 I ablattaaaattaattaaaaiig lot SA irnisra i d :5 yl Li (71 4'1 rr NV7020\27020 E5.1.dwg, 3/30/2007 10:21:18 AM, Adobe PDF ' ELECTRICAL LEGEND POWER SYMBOL 0 COMMUNICATIONS T- -D LIGHTING CONTROL $ 1) 0 AFT A AWG CB D.EC COST EQUIP FA FOIC GOAD GFl FP ICI DESCRIPTION DUPLEX RECEPTACLE MOUNTED AT 15 UNLESS NOTED O1HERNASE QUAD PLEX RECEPTACLE MOUNTED AT 15 "AFF UNLESS NOTED OiHERYASE DUPLEX ISOLATED GROUND TYPE RECEPTACLE (1G5392CN ORANGE) MOUNTED AT 15'AFF UNLESS NOTED OBIERMASE QUAD PLEX ISOLATED GROUND TYPE RECEPTACLE MOUNTED AT 15'AFF UNLESS NOTED O1HERNASE DUPLEX GROUND FAULT INiERRUPTNG TYPE RECEPTACLE JUNCTION BOX MOTOR CONNECTION DISCONNECT SWITCH SINGLE SECTION PANEL8OARD BRANCH CIRCUIT HARING CONCEALED ABOVE CEiLNG OR IN PARTITION CIRCUIT HOME RUN ROUGH-IN FOR TELEPHONE VOICE LINE MOUNTED AT 15"AFF UNLESS NOTED OiHERNASE ROUGH-IN FOR TELEPHONE DATA LINE OR DATACO<1 MOUNTED AT 15 "AFF UNLESS NOTED OTHERWISE EMPTY CONDUIT FOR TELEPHONE CABLES TO BE INSTALLED BY C AMUNICATiNS SUB CONTRACTOR EMPTY CONDUIT FOR DATA CABLES TO BE INSTALLED BY DATA COM SUB CONTRACTOR WALL MOUNTED TOGGLE SWITCH 3-WAY WALL MOUNTED TOGGLE SNATCH S1.DNG DRUM SWITCH (LENTON OR EQUAL) PROGRAMMABLE TIME SWHTOH (TO CONTROL STOREFRONT LIGHTING CIRCUITS) ABBREVIATIONS ABOVE FLASHED FLOOR AMPERE AMERICAN WIRE GAUGE CIRCUIT BREAKER D ECIMAL DIST= EQUIPMENT ARE ALARM NSTAIIEDD B f MC. COMM GROUND GROUND FAULT NTERUPiER HORSEPOWER ISOLATED GROUND J-BOX KW NIC PHIL SPECS SW TEL TYP V W VP PH XFIAR .UNCTION BOX KILOWATT NOT N CONTRACT PANEL SPECETCA110NS WATCH TELEPHONE TYPICAL VOLT WRE WEATHERPROOF PHASE TRANSFORMER ELECTRICAL SPECIFICATIONS NOTE MANUFACTURER'S NAMES ON THCH THIS SPECIFICATION IS BASED IOWAIE TEE 1111 UU QUALITY OF PRODUCT REQUIRED SiUBSTITUTION MAY BE MADE TO THOS: SPECKED E DEWED EQUIVALENT BY TIE CA NER'S REPRESONTAIIW. ILL. WORT( AND PRODUCTS SHALL MEET THE REQUIREMENTS OF THE UNLORD. 1. TIE CENFRAL CORONERS AND SUPPLEMENTARY GENERAL CONDI110NS SHALL BE CONSIDERED AS PART OF THIS SPECUICATION . 2. ALL INDK TO BE ACCORDANCE NTH TIE RULES AND REGULATION OF TIE LOCAL AUTHONTIFS HAVING JURISDICTION AND THE MOST RECENT EDNIION OF NATIONAL ELECTRIC COOE 3. CONTRACTOR SHALL FINE PLANS NTH MD OBTAIN APPROVALS FROM MUNCPAL AGENCIES ALL POINTS AND CERTIFICATES OF INSPECTION SHALL BE MANED AND PAID FOR BY THE CONTRACTOR. PERTINENT CERTIFICATES SHALL BE DELIVERED TO THE GONER'S REPRESENTATIVE. PRiOR TO F11AL BUNG. 4. CONTRACTOR SHALL VISIT SITE PRIOR TO BDONG. BIDS SHALL SERVE AS E IOENCE OF iONOMLEDGE OF EXISTING COMMONS. HE SHALL CAREFULLY EXALINE THE DIMING CON ON= NODS AND MUTATIONS THEREOF. HE SHALL ASCERTAIN COMMONS UNDER MUCH TIE WORK MUST BE PERFORMED, INCLUDING THE HANDLING OF MATERIALS. SECURITY AND UITNG FED DIMOISIONS. FURTHER THIS CONTRACTOR SHALL PROVIDE FiEEED WMIFiCATION OF LOCATION OF POINTS OF CONNECTION TO LANDLORD'S ELECTRICAL AND TELEPHONE EQUIPMENT AND DISTANCE FROM LEASED SPACE. ANY DISIREPANCES TOM THE CONSTRUCTION DOCUMENTS DISO0VERED AS A RESULT CF TIE AFOR'OENUIOIED FED SHURWY, SHALL BE BROUGHT 10 THE ATiENiION OFF DE O*ER'S REP 01TA1LVE. PRIOR TO COMMENCING ANY WORK. ANY ADDHIONAL COSTS RIMING FROM CONTRACTOR'S FAILURE TO DO SO SHALL BE NS RESPONSiBNNTY AND SHALL IE BORNE BY HMI. 5. ELECTRICAL CONTRACTOR SHALL RECORD ALL FELD CHANGES N HIS WORK AS THE JOB PROGRESSES; AN ACCURATE RECORD OF ALL INK AS ACTUALLY INSTALLED. UPON COMPLETION OF TIE YORK AND BEFORE FINAL PATIENT IS AUTHORUED. SAIL TURN OVER TO THE OMENS REPRESENTATIVE A RECORD SET OF PRINTS SHONIG THESE MMES. 6. SUNK MAiERML LISTS AND SHOP ORAINGS FOR MAJOR EQUIPMENT TO THE OMENS RTAIIVE FOR REVIEWL SUBNiTALS SHWL BE IN ACCORDANCE NTH GOERAL CONDITIONS AND SHAD. BEAR THE STAMP OF TIE ELECTRICAL CONTRACTOR SIOMNG THAT HE HAS REViiIEMED AND APPROVED THEM. LACK OF SUCH CONTRACTOR'S APPROVAL NM IL BE CAUSE FOR RE ECTLON MTHOUT REVIEW BY THE OMER. 7. TINS CONTRACTOR SHALL DO ALL CUTTING, CHASING, OR CHANNELING AND PATCHIG REQUIRED FOR ANY ROTC HEREIN SPECKED. ALL OPENINGS THROUGH STRUCTURALLY SUPPORTED SLABS MUST BE CORE- BORED, SLEEVED. CROWED. SLICED AND MADE WATERPROOF. SLEEVES MUST EXTEND AT LEAST 2" AFF ALL SLEEVES, OPENINGS. ETC: THROUGH FiRE RATED WALLS AND FLOORS SRAM BE SEALED AFTER CONDUIT NSTAUA1KON 10 RETAIN FIRE RANG 8. ALL ELECTRICAL MAORK SHALL BE NISTALLED SO AS TO BE READLY ACCESSIBLE FOR OPERATING, SER IMIG,, MANTMIIG AND REPAIR HANGERS SHALL NICLDE ALL MISCELLANEOUS STEEL, SUCH AS CWIELS, RODE, ETC.. NECESSARY FOR THE WALLOON OF ITORK AND SHALL BE SECURED 10 TIE BINDING STRUCTURE, NOT 10 PIING OR DUCTWORK. ALL CONDUIT SHALL BE CONCEMED MAERE POSSIBLE EXPOSED CONDUIT SHALL BE RUN N STRAIGHT HIES MAW. TH CR AT RIGHT ANGLES TO COLJW LIES AND SEPARATED AT LEAST S FROM WATER LIES WEREW R THEY RUM MaNG SIDE CR ACROSS SUCH LN£S 9. (WRY PART CUBE INSTALLATION SHALL BE TESTED, OPERATED AND LEFT N PERFECT 11I00I1 ORDER SHOUD TESTING REVEAL ANY OT HER DEFECTS, PROMPTLY CORRECT SUCH DEFECTS AND RERUN TESTS Ui1M. THE ENTIRE NSTALLATTONI IS SAISFACTDRY N ALL RESPECTS. 10. GUARANTEE CONTRACTOR IS TO GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR AFTER TIE DATE OF ACCEPTANCE OF THE PROTECT BY THE OMEN. IT IS UNDERSTOOD BY NS ACCEPTANCE OF TIE CONiRAUCT THAT 11S CONTACTOR WJLL MAKE GOOD ANY AND ALL WORK WHICH N ANY WAY HAS BECOME DEFECTHE AS TO 1E OMIT OF WARMS AND NORIGUNSiw FOR ANY CAUSE OTHER RUN ORDINARY WEAR AND 1EIL FDR BE SAME POND% BECi11CM. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE PREMMiSES CAUSED BY DEFECTS N WORKMANSlW OR N THE *ERIC OR EQIWIEilIT RUINI9ED AND/OR NSTNJID BY I& 11. THE CONTRACTOR, BEFORE FILAR ACCEPTANCE BY THE OM#R V L BE GRANTED; SHALL CLEAN ALL UGH= FO(RUlE , DEICE RATES. SERVICE FTiNGS AID OAER INNS NUiN19ED INKIER INS CONTRACT. I E SHALL INSURE THAT ALL ORRCiO RES ARE N PLACE NTH COIPLEN D OR REVISED SCHEUAES AND ALL DFJAIICA110NS MD WRONGS OF EMINENT. CABLES MO 0101 ITEMS ARE 12. THIS CONTRACTOR SHALL COORDINATE SEQUENCE OF DORIC NM ALL OILIER TRACES: CONTACTOR SHALL WRIT VOLTAGE CF MEOWICAL EQUIPMENT NO FLUORESCENT FIXTURE BALLASTS PRIOR CONDOM ANY MANIC NO REMOVALS SILL SE WOE NRIOUT OMER'S NITIOIM.. NI ONSING EQURE U; WEEMS. ETC THAT ARE NOT TO BE REUSED SHALL BE MEND COMPLETELY AiD DISPOSED OF BY INS CONTRACTOR 13. NIS CONTRACTOR SHALL WYE ARRANGEMEMS FOR TEMPORARiY POAO NO SAL PAY THE COST FOR THE URIJIY COMECIOI NO SHILL BE WORM FOR NE PROPER MANREJWICE OF it WORMY ECK AND FOR it REU04fM OF S E. CONDUCTOR SHALL PAY ALL MUTT CHARGES N COItCAON N1! 1E TEWCRARY POKER C TRACCRMR; SHALL FR NNE MOIID FAULT MECUM FM ALL POND EQUPMDRT USED ON THE PRE]NSES DUIRNNG CONSMAUC IOM 14. 15. SCOPE OF WORK CONTRACTOR SHALL FURNISH ALL LABOR. mows. SUPPLES EQUIPMENT AND FEES REQUIRED TO COMPLETELY INSTALL, TEST AND PLACE THE HERON S'EOFED EQUIPMENT, COMPONENTS, CONTROLS, AND SYSTEMS N SERVICE. COMPLETE POER AND UGIHWG DISTRBUIOT SYSTEMS NICLUDIIG ALL PANELS AND COMPLETE BRANCH CNRGNT NMRNG SYSTEM COMPLETE UTUTY MOTOR MUG SYSTEMS (EXCEPT AS NOTED) COM TE UGHTIIG FUTURE iISTALLARION COMPLETE TELEPHONE =NUT SYSIOL CONDUIT FROM PONT OF CONNECTION TO LANDLORD'S SYSTEM AND ALL iERMNAL DEUCES. BOXES, CONDUIT. PLATES, ETC. TEMPORARY ELECTRICAL SERVICE AS REQUIRED FOR CONSTRUCTION MIRING MD FXNAL CONNECTION TO ALL S906 AND GRAPHICS, FURNISHED BY THE OVER PRONIS1016 FOR ENE ALARM/9O4C: EVAGUA1ON SYSTEM AND EXTENSION TO LANDLORD'S SYSTEM TESTING OF ALL CABLES AND CIRCUIT MNG AFTER INSTALLATION TESTING OF ALL ELECTRICAL EQUIPMENT WARRANTY OF ALL WOW FOR A PERIOD OF ONE YEAR FROM DATED OF PROJECT CLOSE -OUT ELECTRICAL SERVICE PROVIDE ELECTRICAL AS INDICATED ON THE CRATING. ALL WORN( NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR TIE POLAR COMPANY SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE MIRE NSTALUU110N NTH THE POSER COMPANY. CONiRACTORR SHALL MAKE ARRNIGENENTS TAM THE LOCAL UIUTY FOR INSTALLATION OF MEIERN1G 16. CONTRACTOR SHALL MAKE ARRANGEMENTS YiM 1E LOCAL iEIEPHOFE UNITY FOR TELEPHONE SERVICE TO THE SPACE, CONDUIT SYSTEM FOR TELEPHONE OISIRBUI1ON TO THE LEASED PMTS SHALL BE PROMBED WERE REQUIRED FOR UNITY COMPANY TARES. COORDINATE NSTALLAIION OF TELEPHONE WORK AND INSTALL ALL CONDUIT FOR TELEPHONE SYSTEM. OUTLET BOXES SHALL BE 4' SQUARE MUMMY MM SINGLE DEICE COMER AND TELEPHONE PLATE PROVIDE II ERNORR TIN 4-0 PLYWOOD 24' X 24' TO SERVE AS TELEPHONE TERMINAL BOARD. 17. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS TO PERFORM EIECTiRICAL WORK SHOT, NOTED OR SQEIM ED FOR A COMPLETE MD FUMED NSTMIATIONL 17.1 THE WORD "PROVIDE" AS USED iEREN MEANS TO FURRNS1I AND NNSULL COMIPLETE. 17.2 MATERIALS, PRODUCTS AND EQUIPMENT,11WJDN16 COMPONENTS THEREOF. SHALL BE NEW AND SUCH AS APPEARS ON THE UNBERWILTER'S LABORATORY LIST CF APPROVED ITEMS AND SHALL MEET TIE REQUIREMENTS OF RECOGNIZED STANDARDS 17.3 EMMERT SHALL BE SIZED N CONFORMITY MM REMREjEOIITS OF THE NATIONAL ElEC1RICAL CODE AND OTHER APPUCARE CODER 18. CONDUIT SHALL BE STANDARD 51W, RICO; NC OR EMT (TM WALL) ACCOROBG TO CODE REQUIREMENTS. CONDUIT SHALL BE CONCEALED N UNSHED AREAS, EXCEPT AS 011101NSE APPROVED BY c ER'S REPRESENTATIVE. 19. RACEWAYS SHALL BE SURFACE METAL TYPE OF THE 97E MD 01111110. REQUIRED FOR SERVICE CO STR UCiID OF CALUMET/ STEEL N11 SNAP -ON COVERS NTH 1/8" MOLL MNG SCREW KNOCKOUTS N BASE APPRONOMATTlY 8" O.C. PROVIDE F 111105 INDICATED NEH MATCH AND MATE NM RACEWAY. FINISH 1111H MANUFACTURER'S STANDARD FINE COATING SUITABLE FOR PAINING. 20. ALL CONDUCTORS SHALL BE SOFT DRAIN. ANNEALED COPPER. NTH 600V NSUAIOMt 20.1 #10 AND SMMIER - SOLD 1111H SINGLE BRAID OR SNARED # 8 AND LARGER - STRANDED NTH AT LEAST DOUBLE BRAID. MOM WIRE SIN SHALL BE #12, EXCEPT #14 RAY BE USED FOR COMM APPUCATHONS. 20.2 ALL 1RE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SiE N UNBROKEN PAICKAAES 20.3 GENERAL. M/INIG SHALL HAVE TINT, 1!N OR THIN INSULATION. 20.4 MJIIUI CONDUCTORS ARE NOT PERISHED FOR BRANCH C CULT 1HRIIG. 20.5 HIRES SHALL BE COLOR COOED N IKEIP IC VIII NEC STAOAROS 21. OUTLET BOLES AND COVERS SHALL BE ONE PECE, CALVMIZEO OR SHERAMXZED SIEOEI, ROKOCK-AR TWE 111j1I(TURE SILOS AS REQ. J11C1ONH BOXES, PILL BOXES NO COVERS SHALL BE GALVANIZED S"ED, CODE GAUGE NO WE- 22- U IC IDEMX & WALL 90013. 91161E POLE, DOUBLE POE; MO THREE WAY SHALL BE MEWL DIM, FWSUL TOGGLE SNTOESC SPBCI'TCAIIOI GRADE. 20A, 120/237V. SCREW VIALS MANJFACTJRES SHALL BE HUiBBEL, BRYANT. PASS NIL SEVERE, OR LEMIROL MEWL DUTY DUPLEX RECEPTACLES SHALL BE 2-POIE. 3-iE MOM TWE, SPECFICA101I GRADE 20A,12S4 NE1A 5-208 UNLESS O1ERM9E NDICAN ,. MANU'AC1RE'S SHALL BE TRILL, BRUNT, PASS NO SEYMORRE OR LEMMA GROWS FAULT INTEL LPIER RECEPTACLE STALL BE GENERAL DULY: DUPLEX RECEPTACLES. GROUND MI CIRCUIT 14101RUPTER, m -1111DU6N TYPE; OAPABLE OF FRONCINI6 CONNECTED DONlSiWMN REIEPTADES ON A S IGlE CRQUT. mom TYRE 1L-RATED CIASS IL MP 1, 20A, 1204 60 1Q 1111 SQD - STATE GROUND PART SOONG MO 9G1AMJIQ 111E 5 MILW MPOIES GROUND-FAIT ARP SEWS*; N IEMA 5-158 C mQIANOIL MARNJFAC L ERS SHALL BE B! 1 I. OMIT, PASS MO SEOMORE, OR MINX DUPLEX ISOLATED OROUIO TYPE RECEPTAQE SHALL BE 2-ILE, 4-1111E, 15A SiRAMQKT DIME DEVICE UM SEPARATE 6NMED MOO MO BUNTING MOUND CEWNECTIits, N HEMA 5-191 CONIIQRATOL AS WNIFACRUi6L BY 11»L HG - 5�3SZ MY RECEPTACLE DRAT 6 RISTANIED AT OR MR 37 ems SHALL BE Mums GAOIO UP Ate ANT RE ZPTAQE NAT 'A INSTALLED AT OR ABOVE 38 NOES SWILL BE NSTAiIED GROERO OXINL SEE GETN. 23. THIS CONTRACTOR SHALL PRONE. INSTALL AND CONNECT A COMPLETE SYSTEM OF GROUNDiIG FOR ALL EQUIPMENT AND STRUCTURES. A 0000 REMAND/ AND ELECTRICAL CONNECTION SHALL BE MADE NTH APPROVED GROUNDING CONNECTORS. 24. UGHiNG PANEL BOARD STALL BE 3 -PHASE 4-MERE OISTRBUND PHASE TYPE MOTH SOLD NEUTRAL GROUND LUG. GROUND BUS AND NUMBER OF CIRCUIT BREAKERS AS SHOMM ON THE PANEL SCHEDULE. BUSWAYS SHALL BE HARD DRAIN COPPER. CARNET SHALL BE CONSTRUCTED OF CORE GAUGE STEEL METH HINGED DOOR HAVING DIRECTORY CARD. FEATLY MD PROPERLY 'ASCRIBED AND SET N FRAYS NTH TRANSPARENT COMER 25. PROVIDE SAFETY MD DISCONNECT SNLTCIES, FUSED OR NON- FUSED, AS CMIED FOR ON DRAWS AND AS REQUIRED BY CODE. SNICKS SHALL BE HEAVY DUTY. LOAD AND HORSt:POMER RATED AS WNUFAC1URRD BY SQUARE -0, GENERAL. ELECTRIC. OR EQUAL SMTCH ENCLOSURE 10 BE SUITABLE FOR APPUCA11ON. 26. 28. 29. DECIMAL SYSTEM AND EQUIPMENT GROUNDS SHALL COMPLY 111H ALL LOCAL, STATE AND NEC CODES AND REGUA110N.S PANELS. CONDUIT SYSTEMS, MOTOR FRAMES, LICKING FIXTURES AND OTHER EQUIPMENT THAT ARE A PART OF THIS IISTAHA1ION SHALL BE SECURELY 010111DED BOTH MECHANICALLY MD ELECTRICALLY N ACOORDMICE MM ALL CODES. MAN GROINDNG SYSTEM SHALL BE 9ZED TO CONFORM NTH SECTION 250, TABLE 250-66 OF TIE NATIONAL ELECTRICAL CODE. PROVIDE CONDUIT TO PROTECT GROUND WE FROM DAMAGE TO AN AREA 6 FT. MOW FLOOR. MAKE ALL JOINT'S AND CONNECTIONS OF THE CONDUIT SYSTEM TIGHT TO MAINTAIN CONI U UY OF MECHANICAL AND ELECTRICAL GROUND THROUGHOUT MIRE SYSTEM. GROUND ALL 3 TORE RECIPTAOES TO THE OUTLET BODES GROUND NEUTRAL FROM THE TRANSFORMER CONNECTED TO WATER LNE. GROUND CONDUCTOR SHALL BE SUPPLIED N ALL NON- METALLIC CONDUIT. ALL BREAKERS SHALL BE BOLTED 1W, 'DERMAL MAGNETIC NTH ALL MO OR THREE POLE eREAJORS HAVING COMM TRIP. ORCNT BREAKERS SHALL BE RATED FOR MAIN I M 10,000 AMP SI M1ETRICAL SHORT CIRCUIT CURRENT AT 12O/206V. CIRCUIT BREAKERS SERVING UGHTNHG CIRCUITS SHALL BE RATED FOR SNITCH SERVICE PMETBOARDS MO BREAIX'FRS SHALL BE AS MANUFACTURED BY SQUARE -D OR EQUAL. PANEL SHALL BE CIRCUITED SO THAT THE LOAD IS OISIRBUTED EVENLY ACROSS ALL THREE PHASES. FUNS/ AND NSTAlL DUAL ELDIENT CURRENT UN= FUSES OF TYPE MID OPACITY DESIGNED TO PROTECT SYSTEM AGAINST AVAILABLE SHORT CRCUIT FAULT CURRENT. I REQUIRED: PROVIDE ORY -TYPE TRANSFORMER INCH SHALL BE COYPLEIELY ENCASED EXCEPT FOR MIMING OPENNN1GS 1M111 KVA AND VOLTAGE RATINGS AS CAL! ED FOR ON THE ORATING AS MANUFACTURED BY SQUARE -D. TRANSFORMER SHALL HAVE A IW. M OF CLASS 155 NSUATION SYSTEM. AND A MUNN OF (4) 2 -1/2 Z TAPS BELOW AND (2) 2 -1/2 OY TAPS ABOW RAND MARY VOLTAGE SOUND LEVEL SHALL BE LOW AND NNSTALLAIION SHALL NCLWE MOM DMIPOIIG MOUNTS AND FIEOOBLE STEEL CONDUIT FOR PRNARY MD SECONDARY. 27. LIGHiING FEXMME& 11E CONTRACTOR SHALL PROVIDE A NEW UCKTNIG FIXTURE OF TIE TYPE SPECKED FOR EACH 110111NHG OIUiLET SHOMV MM C MPI ETE LAMPS OR TUBES ALL FIXTURES SHALL BE MIND AND MOUNTED N PLACE PROPEHa.Y WEED. TESTED AND LEFT READY FOR OPERATION. PPAIMNO.ELECTRICAL COMM ETC. F REQUIRED. XL BE BY GENERAL FMIALLY: R HS THE PURR THAT THE FOREGOING WORK SHALL BE COMPLEN N EVERY RESPECT AND THAT ANY MATERIAL OR WORIC NOT SPEINiCALLY IFIMONED OR 910111I ON RE DRAMRIGS, BUT NECESSARY TO FULLY COMPLETE THE =RIC SHALL BE FLJ WISHED. THE LOCAiHON OF RECEPTACLES AND FIXTURES SHOOT ON THE DRAMWM IS APPROXIMATE AND DE OMER SHALL HAVE THE RIGHT TO RELOCATE ANY RECEPTACLES OR FIXTURES BEFORE THEY ARE INSTALLED T1TOUT AMORAL COST. PROVIDE STRAIN RELIEF - ELBOW AT CONNECTION TO JUNCTION BOX. FLEXIBLE CONDUIT TO S-0 FROM FLOOR. IVASTLOCKS FOR CONNECTION TO EQUIPMENT. TWIST -LOCK OEiICES NOT TO SCALE EQUIPMENT GROUNDING CONDUCTOR SIZED PER NEC 250 -122 BONDED TO ENCLOSURE (TYPICAL) JUNCTION BOX BAKERY ARCH LiQUIDTTTE FLEXIBLE CONDUIT (6'-O' MAX.) EpUiTPMIENT EQUIPMENT CORD (NOT USED.) ( RECEPTACLE GROUND LOCATION DETAIL NOT TO SCALE BAKERY ARCH EQUIPMENT DETAIL 1/0 CU. GROUND ABOVE DUPLEX RECEPTACLE 0 37' AND BELOW NOTE: ALL ISOLATED GROUND RECEPTACLES SHALL HAVE A SEPARATE INSULATED /12 CU. CONDUCTOR TIED TO THE GREEN GROUND SCREW OF THE RECPTACLE AND RAN TO AND CONNECTED TO THE PANEL GROUND BAR. MULTIPLE CONDUIT SUPPORT DETAIL NOT TO SCALE • • • • • NOT TO SCALE / - GALVANIZED 1/2' BOLT THREADED RODS DOUBLE NUT WITH WASHERS SUB PANEL 'CPI PANEL" DUPLEX RECEPTACLE 0 38" AND ABOVE 1 -1/2' X 1 -1/2' GALVANIZED CHANNEL OR STRUT CONDUIT FROM 800A FUSED DISCONNECT INCOMING NEUTRAL /GROUND CONDUCTOR NEUTR NEUTRAL BAR (ISOLATED) PLASTIC BUSHING d GROUND BELOW �VV 1 1 CODE COMP NFPA 70 - NEC APR 1 3 2007 City Of Tukwila B ILDIN I 1 I N LIGHTING OR POWER PANELBOARD CABINET (208 VOLT) E QUIPMENT GROUNDING CONDUCTOR SIZED PER NEC 250 -122 CONDUIT NEUTRAL BAR (ISOLATED) GROUND BAR TYPICAL BONDING AND GROUNDING DETAIL i N:\27020 \27020 E5.2.dwg, 3/30/2007 10:22:03 AM, Adobe PDF • BAKERY CAFE: # 1 2 1 5 SYSTEM: G2 ( a% Pito E W o' cits WV =W W= C4 LL< {E, 8/10/07 LO Q Y N_ IX a D. OC H.. In 0 L1 O F Q CO Z V - Z W = : IX - w W =u)� Y � ISSUE DATE: 2 -16-07 PROJECT NLAI®ER *06 -506 ABOSSEN PROJECT: #2702 DES OWO BY: O6. SH. GNG OiECKED BY: AVA I i SHEET NO. E5.2 ELECTRICAL �� SPECIE Al1O G i