Loading...
HomeMy WebLinkAboutPermit EL07-399 - INSPAINSPA 17100 SOUTHCENTER PK SUITE 112 EL07 -399 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: 2623049081 17100 SOUTHCENTER PY TUKW WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE WA BOB RAU 15321 105 AV CT E , PUYALLUP WA Contractor: Name: R -C TRUE LINE CORPORATION Address: 15321 105 AV CT E , PUYALLUP WA Contractor License No: RCTRULCO38QG DESCRIPTION OF WORK: INSTALL LIGHTING AND OUTLETS FOR NEW TENANT. PANELS AND HVAC WILL BE BY SHELL CONTRACTOR. Value of Electrical: $28,990.00 Type of Fire Protection: SPRINKLERS Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us INSPA 17100 SOUTHCENTER PY, SUITE 112 , TUKWILA WA Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: The granting of construction or Signature: Print Name: doc: EL -4107 ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 -377 -7111 Phone: 253 845 -8775 Expiration Date: 11/07/2007 Fees Collected: National Electrical Code Edition: EL07 -399 09/24/2007 03/22/2008 $697.00 2005 Date: d I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. thority to violate or cancel the provisions of any other state or local laws regulating ed to sign and obtain this electrical permit. Date: 9 , (_ / `67 rz a- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. EL07 -399 Printed: 09 -24 -2007 Parcel No.: 2623049081 Address: 17100 SOUTHCENTER PY TUKW Suite No: Tenant: INSPA 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA TO - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. T: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give au laws regulating co :,��, lion or th pe . mance o wo Signature: Print Name: doc: Cond -Elec City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: ELO7 -399 Status: ISSUED Applied Date: 08/16/2007 Issue Date: 09/24/2007 o violate or cancel the provision of any other work or local Date: EL07 -399 Printed: 09-24 -2007 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenfer Blvd., Suite 100 Tukwila, WA 98188 htto://www.cltukwila.wa.us Site Address: Q Sow h Ce Tenant Name: J- i-, 'j Property Owners Name: 3--- Pi • I C Mailing Address: 1g/7 / j � 4 / 1-12 - j E_ CONTAti, RSON Name: Mailing Address: 15 / / 2$ " E-Mail Address: ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** ELECTRICAL CONTRACTOR INPORIVIATI » Company Name: X C 7 - � Al Or Mailing Address: / 53,a / / 0 5—'r 4 I �- jee 3 /' Contact Person: (�iQ1 City F S tate 2;p �C L' / !� ('..r. �'� G' Day Telephone. 5, ^ � �,�►�"`,1 r� E -Mail Address: C am' ,1i-C O/k( Fax Number: - .9 5' 96,,� Contractor Registration Number: C r ) c.o .3 Q�" Expiration Date: // " 7 -lye a HAA pplicationsTorna- Application On LineW4007 - Electrical Permit AppliaiOndoc do we cant v hen yelirp rg by Day Telephone: R Cit y r State Zip 4e Of Fax Number: '� 9 — 4 mg Co Assessor's Tax No.: Suite Number://.....2, New Tenant: City Floor: / r< Yes ❑ ..No 14 9 State Zip Valuation of Project (contractor's bid price): $ .2. / ? ff Q , D b Scope of Work (please provid detailed info ation): o f 4 44 d 0.0 Will service bp altered? ❑ Yes o Adding more than 50 amps? >rYes ❑ No Type of Use: Tv ne -- -e ofwo ❑ New ❑ Addition ❑ Service Change 0 Remodel Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served :: 'Puget Sound Energy ❑ Seattle City Light Page 1 oft RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits 810.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair 865.00 ❑ Low voltage systems 855.00 (alarm, furnace thermostat) Mailing Address: / / Date Application Accepted: 0 IV 1 lApplicationaV'orma-Applicationa On Unok -2007- Eladricd Permit Appliution.doc $140.00 875.00 ea $55.00 ea c Date Application Expires: 2 MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within I80 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 11 DING t .1 I R LECTRIC 1��.w M; +. CTOR: plirr of, Signature: Date: Print Name: ,COI e '- 7 MISCELLANEOUS FEES ❑ Temporary service (residential) 858.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service 880.00 (excluding garage or outbuilding) ❑ Carnivals 875.00 Number of concessions 810,00 ea 8' Staff Initials• Page 2 of 2 Day Telep 1 e: ;Y State Receipt No.: R07 -02075 Payee: R C TRUE LINE ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049081 Permit Number: EL07 -399 Address: 17100 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 08/16/2007 Applicant: INSPA Issue Date: Initials: WER Payment Date: 09/24/2007 02:18 PM User ID: 1655 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Cash 557.60 Account Code Current Pmts 000.322.101.00.0 557.60 Total: $557.60 Payment Amount: $557.60 3119 09/24 9710 TOTAL. 577,60 doc: Receipt -06 Printed: 09 -24 -2007 Parcel No.: 2623049081 Permit Number: EL07 -399 Address: 17100 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 08/16/2007 Applicant: INSPA Issue Date: Receipt No.: R07 -01724 Initials: BLS Payment Date: 08/16/2007 12:25 PM User ID: ADMIN Balance: $557.60 Payee: R.C. TRUE LINE CORPORATION TRANSACTION LIST: Type Method Description Amount Payment Check 3256 139.40 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:206 - 431 - 3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000.345.832.00.0 139.40 Total: $139.40 Payment Amount: $139.40 1D37 02/16 9710 TOTAL 139.40 doc: Receiot -06 Printed: 08 -16 -2007 Project: Type of Inspection: Address: }' �j �,�y/f ✓fi 7 /vU % / /!( t, "�l(! *IVY Date Called: Special Instructions: Date Wanted: /� /� a.m. Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 . _eV INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 Improved per applicable codes. El Corrections required prior to approval. COMMENTS: 01< F/N# 1-- Inspect 4 L 6 t:/ ' , #.11 ' o El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: AISPA Type of Inspection: ' 71_9() Address: / / / 7 1 ) So u ni c'►rwrix P 1 Date Called: y 1/-02-0i Special Instructions: Date Wanted: f /. .2-v'7 a.m. p.m. Requester: 9999 Phone No: . 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Pfr Inspector: i5 Y lV, N - 1)7 Date: $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: Date: Project,� Type of Inspection: / �, l/v 7 Address: �!� - 7/ 00 $D( /�CE/� / «e fw'/ Date Called: Special Instructions: Date Wanted: /o, Z. a.m. ��:� Requester: Phone No: INSPECTION RECORD I Retain a copy with permit U ! , INSPECTION NO. PERMIT NO. U CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 pproved per applicable codes. Corrections required prior to approval. COMMENTS: /On (� lA / L SD � /G/ Ac asS P � 0 1• � Inspect /94'4' I Dat / / / / ( $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: a • r Projec Type of Inspection: U Address: / 7 / ( / V . S ; k h A •✓ 7m ( Date Called: )\1 Special Instructions: Date Wanted: 2 4 �l t a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit F INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION i . 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 COMMENTS: r L , �J1K/ MAIM proved per applicable codes. Corrections required prior to approval. Inspect %G„ 1J17'jg/ ,9/(G /f IDate?4& /0 7 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. !Receipt No.: Date: .,.._., ; .4. ,r . I® L /THON /A L/GHT/NG" FEATURES & SPECIFICATIONS INTENDED USE Ideal for applications requiring attractive general purpose emergency lighting two- headed unit CONSTRUCTION White thermoplastic housing, UV- resistant with snap -fit design components for easy installation. Universal J -box pattern. Track and swivel arrangement permits full range of direction of lamp adjustment. Not intended for ceiling mounting. LAMPS Two 5.4 -watt DC T5 wedge -base lamps for emergency light ELECTRONICS Dual- voltage input capability 120 or 277 VAC. Equiped with test switch, status indicator and a battery that automatically recharges when normal power is restored. BATTERY OPTION Maintenance -free, sealed lead- cadmium battery provides 90 minutes of emergency power. LISTING UL listed. Meets UL 924, NFPA 101, NFPA 70 -NEC and OSHA illumination standards. WARRANTY One year warranty. BWU Family BWU Emergency P CUhREcTION LTR# Catalog Number Notes Type / REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC SEP 1 9 2001 C Of Tukwila ILDING 0 ION FILE COPY hermoplastic Emergency Light BWU Lead - Calcium Battery t 'pt ORDERING INFORMATION All configucations of this product are considered "standard" and have shot lead times. Example: BWU 2 ,. a. SEP 10 2007 EL047-- BILE Sheet #: BWU QMUE -135 SIAM .Thermoplastic Emergency Lighting Unit, BriteWay SPECIFICATIONS MOUNTING ELECTRICAL Primary Circuit Supply Input Max. Voltage Watts Amps 120 5.7 .05 277 5.5 .02 BATTERY -- Lead - calcium Shelf Expected Optimum Voltage lifer life' Maintenance temperature 6 6 months 3 -5 years none 60 ° -90 ° F (16 -32 ° C) Notes: 1 At 77 °F (25°C). 4 Periodic system status test recommended. 5 Optimum ambient temperature range where unit will provide capacity for 90 minutes. L/THON/A L /CHT /ND ® An WicultyBrands Company Sheet #: BWU (02005 Acuity Brands Lighting, Inc., 8/30/07 All dimensions are in inches(millimeters). shipping weight 4.8 Ibs. (2.2 kgs.) I 11 -3/4° (298.4) 16 -1/2" (419.1) 5 -1/8' (130.2) 4" (101.6) SEP 10 71 Lithonia Lighting Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax: 770-981-8141 www.lithonia.com A L /THON /A L /GHT/NG' FEATURES INTENDED USE Suitable for applications requiring both exit sign and unit equipment. Attractive, less than 10 inches tall, streamlined design is great for above -the- door applications and other tight fits. High - capacity version with remote lamps V are ideal for outdoor emergency egress lighting. CONSTRUCTION Engineering -grade thermoplastic housing is impact- resistant, scratch - resistant and corrosion - proof. UL94V -0 flame rating. UV- stable white resin resists discoloration from natural and man -made light sources. Rugged unibody housing snaps together with no additional fasteners. Faceplate and back cover are interchangeable on housing. Positive snap -fit tabs hold faceplate securely, yet pry out easily for lamp compartment access. Universal, directional chevron inserts are easily removed and reinserted. Two 5.4W T -5 wedge -base krypton lamps with multi- faceted reflector and acrylic lenses provide superior optical control. Unique swivel -and -point arrangement permits full -range adjustment in lamp head direction. Uniform graphics illumination without shadows or hot spots. Letters 6" high with 3/4" stroke. Special wording available in red or green lettering. Consult factory. U.S. Patent No. 0484,272, 5,526,251, 5,611,163, 5,797,673, 5,954,423, 6,142,648 and 6,848,798. Canada Patent No. 80,141, 2,180,495. LAMP LED life exceeds 25 years, based on continuous operation. Low energy consumption — only 3.3 watts. BATTERY Sealed, maintenance -free lead- calcium battery delivers 90 minutes capacity to emergency lamps. Automatic recharge after 90- minute discharge. Test switch and LED provide visual and manual means of monitoring system operation. Slip -on battery terminals and polarized battery connector simplify installation and maintenance. Optional high - output battery (HO) to power up to 6 -volt, 12- watt remote load. See chart on back for details. ELECTRONICS Custom microchip charger, developed by Lithonia Emergency Systems, provides increased reliability and maximizes battery life. AC /LVD reset allows battery connection before AC power is applied and prevents battery damage from deep discharge. Two -rate regulated charger minimizes energy consumption and provides low operating costs. Filtered charger output minimizes charge voltage ripple and extends battery life. Thermal protection senses circuitry temperature and ORDERING INFORMATION LHQM Family LHQM LED type, two external Tamp heads ELA MR24 K0606 ELA MR24 H0606 ELA NX H0606 ELA WGHQM Emergency Face type S Stencil Housing color (blank) Black W White Accessories Letter color R Red G Green Number of faces 1 Single face 3 Single face with extra faceplate and color panel Order as separate items. Compact MR24 remote head (6W, 6V) Compact MR24 remote head (6W, 6V halogen) NEMA 4X, sealed -beam remote fixture (6V,6W halogen) Wireguard (back mount only) Catalog Number Notes FILE COPY Type•••• CORRE L.TR# EWED FOR CODE �M�PII SEP 1 9 2007 LHQIVI adjusts charge current to prevent overheating and charger failure. Current - limiting charger circuitry protects printed circuit boards from shorts. Brownout protection. INSTALLATION Top, end or back mounting. Housing snaps to canopy with four positive - locking tabs. Cam locking pin secures housing to canopy. Easily removed mounting knockouts. Conduit entry knockout for 1/2" flexible conduit. J -box pattern on back panel. LISTING UL listed. Meets UL 924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. WARRANTY Five -year total customer satisfaction warranty including LED lamps. For shortest lead times, configure product using standard options (shown in bold). Example: LHQM S W 3 R 120/277 120/277 Input voltage 120/271 Dual voltage Lamp heads (blank) 5.4W/6V Krypton H 6W /6V Halogen' TION NOTES: 1 Not available with HO or N. 2 Choice of FI or FA. Not available with both. EL01 399 FILE COPeY:LHM 4U,4N�T�M® Th rmoplastic Exit/Unit Combo Options LED Lamps ENERGY STAR (blank) None FI Fire alarm flashing interface' FA Flashing emergency operation and intermittent audible alarm (66 times /min.; alarm 75 dB at 100cm) N Maintenance -free nickel - cadmium battery HO High - output lead- calcium battery RO Less lamp heads DL UL t f1r ¢a p Ipcations SEP 10 2007 F t;'� ilia lr AMEX -140 LHQM QUANTUM® LED Exit/Unit Combo SPECIFICATIONS ELECTRICAL Primary Circuit Rated Supply Max. Max. LED life voltage amps watts 25+ 120 .23 3.3 Red LED years 277 .23 3.3 25+ 120 .23 3.3 4EXIT O Green LED years 277 .23 3.3 BATTERY i Shelf Expected Optimum 13 Voltage life life Maintenance temperature' (33) Lead - calcium 6 6 months 5-8 years none 60*-90°F TO P Ni -cad (N) 6 3 years 7 -9 years none 32*-100°F 1 4 r _ (12.4) k. ./ _ Notes: 1 Based on continuous operation. 2 At 77 °F. 10-3/4 (27.3) 4 Optimum ambient temperature range where unit will provide capacity for 90 minutes. __./ Higher and lower temperatures affect life and capacity. Consult factory for detailed information. REMOTE OUTPUT CAPACITY — 1 Combo\ Combo\ Combo \no 2 -5/8 Combo\ Combo\ high- no heads (RO) & ( 7.2) Standard ni -cad halogen output heads high- output combo battery (N) lamps (H) battery (HO) (RO) battery (HO) NA NA NA 12W 10.8W 24W 3 Periodic system status test recommended. PHOTOMETRICS e 4 2 0 2 4 e e 4 2 0 2 MR24 K0606 6-volts. 5.4 -warts krypton _ail` i■�.� `amlm /um 10 Fully assembled at factory. 20 KEY FEATURES Ft. Install only one fixture instead of two. LED Unique LEDs provide extremely long life and low energy consump- tion. or® L /THON /A LIGHTING® An cs4cuityBrands Company Sheet #: LHQM ©1995 Acuity Brands Lighting, Inc:, Rev. 7/20/07 MOUNTING All dimensions are inches (centimeters). Shipping weight: 7.36 Ibs. (3.3 kgs.). BACK 21 -1/4 (54) BACKPLATE 9 -7/8 4 -15/16 (25.1) (12.55) 6-1/2 f { (6.52) 13 (33) FIXTURE PERFORMANCE 0.1 FC min. te 3 ft. • Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes open space with no obstructions, mounting height: 7.5', ceiling height: 9', and reflectances: 80/50/20. Analysis based on independently tested photometrics. SEP 10 ZUU7 t 9 -7/8 (25.1) Test switch /pilot light END Conduit entry knockout EXIT (Universal knockout pattern for various standard j- boxes) MR24 K0606 3'W Path of Egress Single Unit coverage* yields 24' Lithonia Lighting Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone:800- 334 -8694 www.lithonia.com f August 22, 2007 Bob Rau 15321 105 Ave Ct E Puyallup WA 98374 RE: CORRECTION LETTER #1 Electrical Permit Application Number EL07 -399 InSpa —17100 Southcenter Py, Ste 112 Dear Mr. Rau: This letter is to inform you of corrections that must be addressed before your electrical permit can be approved. All correction requests from the Building Department must be addressed and reflected on your drawings. Building Department: Bill Buterbaugh, at 206 937 -4758, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that three (3) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, encl arshallt hnician xc: File No. EL07 -399 P:\Pemrit Center\Correction Letters\2007\ELO7 -399 Correction Ltr #1.DOC jem City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: August 22, 2007 Project Name: InSpa Permit #: EL07 -399 Plan Reviewer: Bill Buterbaugh 1. Approved plans for HVAC installation (permit EL07 -403) shows 4 RTU's on Panel L -112 with a load of 15120VA (5040VA per phase) per unit. 2. Correct panel schedules and load calculations to reflect the HVAC loads and panel designations. 3. New panel is designated as panel L- 112 -A. 4. Exit signs not shown on plans. 5. Egress path requires 1 foot candle at floor along the entire pathway and egress discharge area. ACTIVITY NUMBER: EL07 -399 DATE: 09 -10 -07 PROJECT NAME: INSPA SITE ADDRESS: 17100 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: B i ding Div slon Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: a Planning Division Permit Coordinator DUE DATE: 09-1 1 -07 Not Applicable ❑ No further Review Required C REVIEWER'S INITIALS: DATE: DUE DATE: 10 -09 -07 Not Approved (attach comments) E DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: EL07 -399 DATE: 8 -16 -07 PROJECT NAME: INSPA SITE ADDRESS: 17100 SOUTHCENTER PY, SUITE 112 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building Division Public Works DETERMINAT N OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESITHURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: Documentshouting slip.doc 2 -28 -02 ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP Fire Prevention Structural Incomplete Planning Division ❑ Permit Coordinator n DUE DATE: 08 -18 -07 Not Applicable ❑ Structural Review Required ❑ No further Review Required Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials; DATE: DUE DATE: 09-15-07 Approved with Conditions ❑ Not Ap proved (attach comments) REVIEWER'S INITIALS: DATE: C • Date: Project Name: InSpa Project Address: Contact Person: _/©_ ©7 Summary of Re j sion: �4 City of Tukwila pp Waft ons orms -app icehans on me vision su mitt¢ Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site; http.• / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: EL07 -399 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Steven M Mullet, Mayor Steve Lancaster, Director 17100 Southcenter Py, Ste 112 /30 I) fef-c Phone Number: 2..53 7/77 via Cc e Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: RCOA-/ 41" in Permits Plus on c kt 0 —01 RECEIVED CITY OF TUKWIlA SEP 10 20011 PERMIT CENTER License Information License RCTRULCO38QG Licensee Name R -C TRUE LINE CORPORATION Licensee Type ELECTRICAL CONTRACTOR UBI 601828382 Ind. Ins. Account Id Business Type CORPORATION Address 1 15321 105TH AVE CT E Address 2 City PUYALLUP County PIERCE State WA Zip 98374 Phone 2538458875 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 11/7/1997 Expiration Date 11/7/2009 Suspend Date Separation Date Parent Company Previous License TRUEL * *035KH Next License Associated License RAU *RRH967C3 Business Owner Information Name Role Effective Date Expiration Date RAU, ROBERT H 01/01/1980 RAU, CARLOTTA 01/01/1980 RAU, ROBERT H AGENT 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Master Electrician Information License Name Status RAU *RRH967C3 RAU, ROBERT H ACTIVE https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= RCTRULCO38QG 09/24/2007 ROOM ROOM NAME FLOOR BASE N -WALL S -WALL E-WALL W -WALL CEIUNG REMARKS 100 RECEPTION F1 B1 PT4 PT4 PT4 PT4 PT4 G YP CE WIN MDF BATTENS 12' -6' AF AS SHO ON SHEET A3.0. SE NOTE 2/A3.0. 100B CLOSET F1 B1 PT4 PT4 PT4 PT4 PT4 GWB CEIUNG @ WO AFF. 101 RETAIL F1 Bi PT4 PT4 PT4 PT4 PT4 GYP CEILIN MDF TNS 2'-S' FF AS SH SHEET A3BAT.0. E SE TE 21AA3. 0. 102 MASSAGE F2 B1 PT1 PT1 PT1 PT1 PT5 WD1 CEIUNG FINISH WITH V/02 CROWN MOLDING 0 9'-0r AFF. 103 MASSAGE F2 Bi PT1 PT1 PT1 PT1 PT5 WD1 CEIUNG FINISH WITH IMY2 CROWN MOLDING() W-0' AFF. 104 MASSAGE F2 B1 PT1 PT1 PT1 PT1 PT5 WD1 CEIUNG FINISH WITH WD2 CROWN MOLDING 0 9=0" AFF. 105 HALLWAY Ft Bt PT4 PT4 PT4 PT4 PT4 -1 4(' GLASS MIRROR O OM ON SIDE, LING VIN MDF BANS 1 I'-8' AFF AS GYP CEI S HOWN ON SHEET *3. SE NOTE 2/A3.0. 106 CLOSET F1 81 PT4 PT4 PT4 PT4 PT4 GVVB CEIUNG 0 9r-0' AFF. 107 FACIAL Fi 61 PT3 PT3 F3 F3 PT3 PT4 VVD1 CEIUNG FINISH WITH WW2 CROWN MOLDING 0 9'-0" AFF. 108 FACIAL. F1 61 PT3 PT3 F3 PF3 PT3 PT4 WD1 CEIUNG FINISH WITH VVD2 CROWN MOLDING 0 9'-0" AFF. 109 FACIAL F1 B1 PT3 F3 PT3 PT3F3 PT3 PT4 Di W CEIUNG FINISH WITH VVD2 CROWN MOLDING 0 9'-0" AFF. _ 110 FACIAL F1 Bi PT3 PT3 F3 F3 PT3 PT4 VVD1 CEILING FINISH WITH WD2 CROWN MOLDING 0 9'-0r' AFF. 111 FACIAL F1 81 PT3 F3 PT3 PT3F3 PT3 PT4 W D1 CEIUNG FINISH WITH NAM CROWN MOLDING 0 W-0' AFF. 112 WORKROOM F5 B3 F4 F4 F4 F4 C1 2 X 4 ACT GRID @ 11'41' AFF. 113 MANICURE F1 B1 PT4 PI PT PT2 PT PT2 PT2 C2 OPEN CEILING WITH C2 SOFFITS. PT2 0 13 AFF AND ABOVE. 114 NAIL DRY F1 81 PT4 PT4 PT4 PT4 PT4 GYP CEILING VW MDF BATTENS t0'-0' F .O. AS SH OWN ON SHEET A3.0. SEPNOTE 21A 115 RESTROOM F6 F6 TO ' AF PT3 F3 PT3 F3 PT3 PT3 PT4 F3 F3 CONTINUOUS CONING FROM TOILET FLOOR SHALL EXTEND TO 6' UP THE WALL VIN A 318' COVER RADIUS. 116 RESTROOM F6 46° AFF PT3 F3 F3 P' F3 7'y PT4 SHALL EXTEND TO CONTINUOUS P E WAIL W/ ARC COVER RADIUS. MARK SIZE DOOR TYPE DOOR FINISH FRAME TYPE FRAME FINISH RATING _ , DW GROUP REMARKS D100 01008 NEW STOREFRONT — — — — — — — 3-0" x T-O" x1 D2 PAINT PT5 F2 PAINT PT5 7/A5.0 NA 1 000R 1U U 31111im %VOLD HAD CLOSET D102 3'-0" x T-0" x1 Di PAINT PT5 Fi PAINT PT5 2 RO NNUM ON DOOR D103 3'-0' x r-0" x1 Di PAINT PT5 F1 PAINT PT5 2 1 '4' GLASS MIRROR 0 ROOM SIDE ROOM NUMBER ON DOM (F.O.I.C.) D104 3'-0" x T-0" x I Di PAINT PT5 F1 PAINT PT5 2 '4" GLASS MIRROR 0 ROOM SIp ROOM NUMBER ON WOK (F.O.I.(1) D106 3-0r x T-0" x 1 02 PAINT PT5 F2 PAINT PT5 NA 1_ F BRUSHED SS HU R CLOSET D107 3'-0' x T-0" x1 Di PAINT PT5 Ft PAINT PT5 2 ROOM NUMBER MIRROR SIDE, C.) 0108 3'-O" x 7'-Or x 1 D1 PAINT PT5 Fl PAINT PT5 2 -1 4(' GLASS MIRROR O OM ON SIDE, D109 3'-Or x T-Or x 1 DI PAINT PT5 Fi PAINT PT5 2 -1, GLASS MIRROR 0 ROOM SIM ROO NUMBER ON ,) Di 10 3'-0' x T-0' x 1 D1 PAINT PT5 F1 PAINT PT5 2 1 i" C4 ASS MIRROR ROOM SI ROOM NUMBER ON DOOR (F.O.I.C.) D111 3 1 3'-0'xT-0"x1' D1 PAINT PT5 F1 PAINT PT5 2 ' � NUMBEER OOIV ROOM F SIDE, D112 3'-O" x T-0" x 131' DI PAINT PT5 Fi PAINT PT5 3 .5' 3220 PUSH PP ATE D115 3'-0" x 7=0" x 131' Di PAINT PT5 i Ft PAINT PT5 1 "320 KICK PLATE ON PUSH SIDE. D116 3 x T-0 x 131' Di PAINT PT5 F1 PAINT PT5 1 SIDE 320 KICK PUSH SYMBOL DESCRIPTION DETAIL SYMBOL DESCRIPTION DETAIL . PARTITION WALL. 1851A5.0 Q EXISTING WALL TO REMAIN - PATCH AS REQ ETHER NET (CAT -5 CABLING) Q 2 314" FURRED WALL 2/A5.0 Q INS O S E DA5.0 K PARTITION INSULA VIII DB LA YER 2 SIDESTED . 3851A5.0 PARTITION WALL, WORKROOM 7/A5.0 4 NN DELL L GWB 1 p R 38"A" Q SINGLE LANOT USE 5.0 Q ONE - HOUR -RATED DEMISING WALLL TO STRUM DECK. 4/A5.0 7 PHONE PHONE , 1, DEDICATED FOURPLEX VIN ISOLATED GROUND 7 FAX Q J-BOX RECEPTACLE ISDN ETHER NET (CAT -5 CABLING) 2 DUPLEX RECEPTACLE O THERMOSTAT CONTROL 4 FOURPLEX WALL RECEPTACLE FIRE EXTINGUISHER MIN 5 LB 2A106C WALL RECESSED FE DUPLEX FLUSH FLR RECEPTACLE, FINISH BRUSHED ALUMINUM NOTE: 1. ALL POWER/SIGNAL LOCATED 2. SWITCHES AND COVER PLATES @1•-6' A.F.F. TO CENTERLINE U.N.O. ON WALLS TO BE WHITE 0 0 0 0 0 10 D w 22 E7 E8 KEYED NOTES: RETURN DOOR JAMBS 6' FROM SIDE WALL, EXCEPT WHERE NOTED. OUTUNE OF GWB HEADER ABOVE 0 11 -2' AFF. WATER DISPENSER (FOIC.). PAPER TOWEL DISPENSER - BOBRICK B4262 OR EQUAL OUTUNE OF CASEWORK FIXTURES - SEE CASEWORK DRAIMNGS. PROVIDE BLOCKING IN WALL FOR MENU BOARD CENTERED ON WALL 0 4'-0" AFF. TO T-0" AFF. RESTORATION HA BISTRO DOUBLE COAT HOOK INSTALL 6 AFF. T�RUNE OF MOUNTING PLATE, , P R OVIDE BLOCKING, FINISH CHROME, CENTER ON WALL. RESTORATION HARDWARE, BISTRO TRAIN RACK INSTALL 0 72" AFF. TO TOP OF SHELF, PROVIDE BLOCKING, FINISH CHROME, CENTER ON WALL, UNO. SOAP DISPENSER - BOBRICK 84112, OR EQUAL. WORKROOM COAT HOOKS. PROVIDE 4' X 4' PLYWOOD PANEL WITH REQUIRED BLOCKING AT +96" AFF. TO ACCOMMODATE PHONE AND COMPUTER NETWORK EQUIPMENT. R UC 1 R 02 STR1IP (RS) P ER FINISH SCHEDULE (SEE A1.0), , 103, OUTLINE OF CORNICE ABOVE SW ANSTONE BRAND, COL T OR TAHITI WHO. AND END PANEL TOWEL BAR (FOIC.). PRE - MANUFACTURED P-LAM. COUNTER TOP VITH POST FORM NOSING AND BACKSPLASH; TO BE CUT IN FIELD. COLOR: WHITE. PROVIDED BY GC. CASED OPENING. SEE DETAIL 6/A4.1. UNDERCOUNTER REFRIGERATOR BELOW SHELVING (FOIC.). TRANSITION STRIP (TS) PER FINISH SCHEDULE (SEE A1.0). Yx4' CHAIR RAIL 2'-8' AFF. TO BOTTOM/FINISH PT-4. ONE INCH LETTERS ON SIGN ABOVE DOOR "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED''. WALL MURAL (FOIC.). T VINYL LETTERING GRAPHICS S-4" AFF. TO BOTTOM. WITH PHRASE' FEEL GREAT NOW' ED ON WALL (FOIC.). 48' CLOSET MAID, SHELF TRACK, 4- SHELF ORGANIZER, ADJUSTABLE SHELVING. MODEL 12887, SIN 845157. (FLOOR TO CEIUNG IN LINEN ROOM). EQUAL TO OR BETTER WEISER INDICATOR DEADBOLT MODELS/097701-2060-9158-2, Wf'OCCUP1EDNACANT'. FINIS!): SATIN CHROME FRP WALL PANELS TO 11'-6' AFF. CONTRACTOR TO PROVIDE 2'7(2" NUMERALS FOR ALL FACIAL AND MESSAGE ROOM DOORS. NIC. OWNER SUPPLED EQUIPMENT SHOWN DASHED, TYP. MEP NOTES: LOCATION OF FLOOR OUTLET TO BE IDENTICAL IN ROOMS 102, 103, AND 104. CONVENIENCE OUTLET, VERIFY LOCATION WITH INSPA. ALL ELECTRICAL AND DATA UNES SHOWN CASHNVRAP TO LL BE FED THROUGH ADJACENT WA OR RU TO CASHWRAP FIXTURE THROUGH FLOOR CHANNEL LOCATION OF FLOOR OUTLET TO BE INDENTIC/LL IN ROOMS 108.109.110 AND 111. CONTRACTOR TO VERIFY NEW ELECTRICAL PANEL HAS ADEQUATE AMPERAGE AND PROVIDE CAPACITY REQUIRES. CENTER RECEPTACLE ON WALL PLANE. LOCATE RECEPTACLE 44' AFF. IN ALL MASSAGE ROOMS. SIG COORDINATE EXTERIOR NAGE ELECTRICAL CONNECTION WITH SWAGE VENDOR AND GC. CONTRACTOR TO VERIFY LOCATION OF NEW HOT WATER WORKROOM IS APPROPRIATE ON ORKROOM FLOOR PR OVIDED BRADFORD VIRI TE. IMU--80R608 80 GALLON ELECTRIC WATER HEATER OR EQUAL UTILITY SINK MUSTEE LAUNDRY SINK UTILATUB 12/14 WFAUCET DELTA/2123. OR EQUAL TO VERY FLOOR DRAIN REQUAREMEIIT. NEW FLOOR DRAIN NTH APPROPRIATE SLOPE TO DRAIN AS REQ'D PER CODE GENERAL NOTES: O I CONTRACTOR TO PROVIDE BLOCNG ATALL WALLS WERE FIXTURES. SHELVES AND ACCESSORIES ARE TO BE N IS TAILED! O S SG (F_ OLO) CONTRACTOR TO COORDINATE O3 OWNER TO FURNISH AND INSTALL STORE FRONT SIGNAG REGISTERS/ COMPUTERS. SOUND SYSTEM, GRAIIINICS, PRINTERS, F J( TELEFNO NE & SECURITY CONTRACTOR TO SAFE, OMDE AND C O V4ATE PULL STRINGS REQUIRED. a CHANNEL FLOOR FOR POKER b SIGNAL DISTRIBUTION. SEE FIXTURE DRAWNGS FOR MORE INFORMATION ON TL LOCATION OF OUETS. O5 EXISTING WALLS TO REMAIN SHALL BE PATCHED AND REPAIRED TO RECEIVE SCHEDULED FINISHES. O CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. O ALL GATES AND DOORS TO BE INSTALLED TO PROVIDE 32' JM CLEAR OPEMIG MIEN OPENED TO 90 (MESS POSITION UfSS O1IERYNSE NOTED. O CONTRACTOR TO PROVIDE FIRE TREATED 2X6 OR 2i(8 WOOD STUD BLOCKRG AS READ TO SUPPORT GRAB OARS IN REST ROOMS. WORKROOM MALL HUNG SHELVING. AND ANY OTHER IN LL ATTACHMENTS. O AT FLOOR SINK LOCATIONS PROVIDE ACCESS FOR CLEANING NM INSPECTION. MOUNT FLUSH VMTH VINYL FLOOR. 1® F BOWING F)(TERIOR ENTRANCE THRESHOLD EXCEEDS THE REQUAtW ADA MGM OF'4' _ERE DIVE #J REPLACE WITH ACCESSM THRESHOLD RA AND ISED THRESHOLDS A FLOOR LEVEL GANGES AT A�CCESSI6LE DOORWAYS SHALL IIiE BEVELED KITH A SLOPE NO GREATER THAN t12. MOUNT 0 S-5" SEE INT. ELEV. ON SHE A4.0 DOOR SCHEDULE DOOR HARDWARE GROUPS DOOR FRAMES WIDTH 1, WIDTH DOUBLE RABBET POPLAR FRAME STEEL FRAME WALL LEGEND NEW WALL OVERHEAD WALL EXISTING WALL N Fi us x K O 0 F2 d au 0 0 DOOR TYPES DI W2 PAINT GRADE BIRCH PAINT GRADE BIRCH UV SC SINGLE PANEL LOUVERED 13I-FOLD NOTE: ALL HARDWARE MUST MEET CODE REQUIREMENTS FOR ACCESS BY DISABLED. 24' 34' FLOOR PLAN ALL EDGES END PANEL NOTE: NEW EXIT DOOR 0100 SHALL BE OPERABLE FROM THE INSIDE VNTHOUT THE USE OF A KEY. SPECIAL KNOWLEDGE, OR EFFORT. FLUSH BOLTS OR SURFACE BOLTS ARE PROHIBITED PER SEC. 1003.3.1.8. NOTE: PER SEC. 1003.2.8.6.1 TACTILE EXIT SIGN TO BE PROVIDED. HARDWARE GROUPS 1. EA 1R PR BALI. BEARING HINGE,__ 1 LOCK SET: SCHLAGE PRIVACY TCH. JUPITER AL SERIES 28 -7U65 LB, 32D, SILENCERS: IVES SR84, FLOOR STOP: AUTOMATIC DOOR CLOSER SARGENT EN1431, KICKPLATE: ON PUSH SIDE, 101%X34"w, 32D, OR EQUAL SEE KEY NOTE /25 2 LA 112 PR BALL BEARING HINGE. US620, 1 LOCK SET: SCHLAGE PRIVACY _TCH. JUPITER AL SERIES 28 -7U65 L.B. S8/ V it -PROOF DOOR CCL SARGENT EN1431, BOTTOM SEAL • 4301CPK DOOR STOP & HOLDER: IVES WS449, 320. OR EQUAL 3. (3)1!2 PR BALL BEARING HINGE, US626. SOUND -PROOF GASKET: PE W° • x 17'. AUTOMATIC DR CLOSE SARGENT EN1431. BOTTOM SEAL AUTOMATIC L. DOOR STOP & HOLDER IVES WS449 320 PUSH P LATE: ON PUSH SIDE. IVE /8200 3.5" X 15' 32D. DOOR PULL.: IVES 8113.5 32D. WITH PULL PLATE IVES 8311 3.5°X 15" 32D KICK PLATE ON BOTH SIDES,10rhX.i4'Vv, 321). OR EQUAL A- WALL KEY 2 -1' T -11' A-0' A - ►.� ROOM FINISH SCHEDULE (SEE A1.0 FOR FINISH SCHEDULE) 7'-11' 0 • T -11' A - 7 T-11" 1' 0' TYP. POWER SIGNAL KEY 13 = -1 NMI 1111111 11111.1.11MO • KARREMAN + ASSOCIATES larchitecture Man revicy-i r^ :-oval Is subject to MOM and omIsskeg, A. ^r c'.zl r the v: Of mar:;.•: 231 Gowen Place NW Bainbridge Island Washington 98110 Lel / fax 206 842 1253 e -mail fronk0korremon.com CONSULTANTS: FILE COPY ; Permit No. d does not 1 (: ':/'• a/ , . i W 0 City cf Tukwila BUILDING DIVISION REVISIONS o changes shall be made to the scoop of work without prior approval of Tukwila Building Division. Revisions will require a new plan submit!al may include additional plan review fees RECEPTION 1 1oo I, 1 , 3r-0r Q w cc cr Q co w cc 1— w Z Z 0 U= < _ D O T VJ T O- o W o r D n D FLOOR PLAN - SCALE: 114'= 1'-0 ISSUE DATE: 7207 REVISIONS: CONSTRUCT10N SET OD 00 T 0) • •- 47,67 'Ji?= j R4 _ FT. A2.0 399 SITE copy • TYPE SYMBOL. DESCRIPTION MANUFACTURER MODEL WATTSIFIXT LAMP REMARKS A • TRACK HEAD (FLOOD) UGHTOUER LYTESPAN "SOF TECH' 18273WH 37 37 WATT MR16 40 DEGREE (FL). B V TRACK HEAD (SPOT) UGHTOUER LYTESPAN 'SOF TECH' 862731NH 37 37 WATT MR18 DEGREE (NFL). C SUSPENDED TRACK LIGHTOUER - LYTESPAN "BASIC' TRACK 88000 NH OR IL6001WH (CUT IN FIELD) VW 18' STEM KIT 87584 OR 4fr STEM RM i00 - MOUNT 11' - Or' AFF RM 101 & 114 - T 11 8'-8" AFF RM 103 - MOUNT 0 T AFF. © D CEILING MOUNTED LIGHTOUER LYTESPAN ''BASIC'' TRACK 88000VNi E EMERGENCY EXITIUGHTING LITHONIA LHQM 5 MR24 F O NOT USED G PENDANT FIXTURE UGHTOUER LYTESPAN PAR-TECH PAR30 8201WH WITH 8235WH CONE SHADE 60 50 PAR30 HALOGEN NARROW FLOOD. ON 80781NH EXTENSION WANDS ON TRACK. H r PENDANT FIXTURE REJUVENATION - (888) 401 -1900 HUMBOLDT MODEL #0550 POLISHED NICKEL FINISH 80 • A19 SHADE 1550P SHADE 8 SHINY OPAL, MOY ' AFF IXTURE VW CHROME CHAIN HUNG FROM CEIUNG WITH DIMMER SWITCH. 1 Q} �' WALL BRACKET REJUVENATION - (888) 401 -1900 ST. HELENS 11151 POLISHED NICKEL FINISH 40 A19 SHADE 155 -6 SHINY OPAL MOUNT S'- 8�'AFF IN FACIAL AND GE RO UP) & re IN RESTROOS (POINT DOWN). J % WALL BRACKET REJUVENATION - (888) 401 -1900 ST. HELENS #1151 POLISHED NICKEL FINISH 14 COMP. FLUOR. 14W BUU3 NOT USED K .k+ COMPACT FLUORESCENT WALL BRACKET FORECAST 8F412 -38E1 'MADISON' 26 QUAD TUBE COMP. FLUOR. SHADE - WHITE CIRRUS GLASS M�OVNT 4! -VAFF TO BOTTOM L V, 5' COMP. FLUORESCENT RECESSED CAN UGHTOUER LYTECASTER SERIES FRAME-IN KIT #1002F1 17.5 QUAD TUBE COMP. FLUOR. S' DEEP ALZAK REFLECTOR TRIM 11048 (SPECULAR CLEAR). M $ UGHT SWITCH 'ROCKER' TYPE MOUNT03'-Or AFF TO CL OF BOX N $ 3-WAY SWITCH MOUNT @Y -6• AFF TO CL OF BOX 0 i DIMMER WATCH (WHITE) UGHTOUER ZP 600 WHITE MOUNT @3• -r AFF TO CL OF BOX P 1 2k4' RECESSED FLUORESCENT UGHTOUER SPS2GFSVA232 62 2-78 BULB UU 2 WATT PER FIXTURE. S Y EMERGENCY STROBE INSTALL PER FIRE MARSHALL T 0 3' NARROW/WIDTH STRIP FLUORESCENT LIGHTOUER SN3S125HPF 17 1 -T8 FIXTURE INSIDE UGHTING SLOT U ® 2' NARROWIMDTH STRIP FLUORESCENT UGHTOUER SN2S117HPF 17 1 -T8 FIXTURE INSIDE UGHTING SLOT CEILING KEY NOTES: 1O ARMSTRONG 24' X 48' X WANGLED TEGULAR LAY-IN FOR 15118' PRELUDE EXPOSED TEE GRID, 684 WHITE ONSTALLED 6 11'-' AFF.). PROVIDE ADEQUATE SEISMIC memo PER CODE SUSPEMED GRID CEIUNO. FOR SEISMIC SUPPORT DETAIL, SEEI2 & 13/A5.0. ® GYP BOARD CEIUNG WITH BATTENS - GYP BOARD ON FRAMING SYSTEM, APPLY 112' X 61/2' MDF BANS 2' O.C. TO FINISHED GYP 8D. CAULK JOINTS PAINT CEILING & BATTENS AS NOTED ON FINISH SCHEDULE LOCATED ON SHEET A2.0. CEILING HEIGHTS VARY, SEE ROOM FINISH SCHEDULE ON SHEET A2.0 FOR HEIGHTS. START POINT OF BATTEN PLACEMENT SHALL BE ALIGNED WITH EDGE OF WALL RETAIL, SEE DETAIL 11/A6.0. BEAD BOARD CEIUNG (WID1), TYP 9'-0O' AFF. IN ROOMS 102.103, AND 104; 107, 108, 109, 11 , AND 111. SEE DETAIL 141A5.0. PROVIDE ACOUSTICAL BAIT INSULATION IN THE CEILINGS AT ROOMS 102, 103, AND 104 ;107,108,109.110, AND 111. GWB SOFFIT Q T-811Y AFF. SEE DETAIL 1 /A3.0. GWB CEILING ! 10 AFF. DIMENSIONS FOR SCONCE SPACING SHALL BE THE SAME IN ROOMS 102, 103, AND 104. ® DIMENSIONS FOR SCONCE SPACING SHALL BE THE SAME IN ROOMS 107, 108009. 110. AND 111. GWB CEIUNG 012'.8'AFF. TRACKS TO BE INSTALLED ON SURFACE OF CEIUNG. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 CENTER P2 PENDANTS OVER CASH WRAP WITH DIMMER. CENTERUNE OF TRACK FIXTURES TO BE LOCATED 0 CENTERUNE OF PARALLEL WALL OR CASEWORK BELOW. EXISTING CEIUNG PRE- PAINTED FIBERGLASS PERFORMED PANELS (FOIL.). 3505162 33 CEIUNG JOISTS W (3 DEEP, 1-5/8" FLANGE 25 GA) 805182 33 CEIUNG JOISTS 18' (8' DEEP, 1-5/W FLANGE 22 GA) UGHT FIXTURES ARE LOCATED ON BACKWALL BELOW ON CASEWIORK UGHT FIXTURES ARE LOCATED BELOW CEILING CANOPY AT 8*-0" AFF. MASTER SWITCH PANEL LOCATION FOR ROOMS 100.101.105,113, AND 114. 24" SQ ACCESS PANEL TO VAV DAMPER, AS REQ'D. GWB CEIUNG @ 11'-' AFF. APPROX LOCATION OF HVAC SUPPLY AND RETURNS SEE MECHANICAL DRAWINGS FOR EXACT LOCATIONS AND SIZE. CENTER EMERGENCY LIGHTS ABOVE DOORS AND HEADERS. GINS HEADER 0 g-0r' AFF. GWB HEADER @ 10'-0' AFF. GWB HEADER 0 11'2' AFF (MATCH STOREFRONT HEADER). GWB CEIUNG 0 10 AFF. CONNECT CIRCUIT TO MASTER SNITCH PANEL (SEE NOTE /19). ALL TRACK FIXTURES ARE ON DIMMERS. CASED HEADER 0 8-6' AFF. SEE DETAIL 8/M1 FOR ROUGH OPENING. OUTUNE OF CORNICE, SEE DETAIL 9/A5.0. TRACK MOUNTED ON A HUNG PAINTED UNISTRUT. TRACKS TO BE INSTALLED ON STEM KIT Q 11'-W AFF. TRACKS TO BE INSTALLED ON STEM KIT 8'-8' AFF. TRACKS TO BE INSTALLED ON STEM KIT ! T-0 OPEN CEIUNG TO STRUCTURAL LID, SEE 110fA4.0. DIFFUSER KEY: X LARGE SUPPLY LARGE RETURN SMALL SUPPLY SMALL RETURN SMALL EAT SIDE WALL SUPPLY SIDE WAIL E)01AUST t • • • A -xi a -19, j,l b GENERAL NOTES: CROWN MOLDING (WD2) TYP AT ROOMS 102, 103, 104, 107, 108, 109, 110, AND 111. EXTEND SPRINKLER HEADS AS REQUIRED AT WOOD CANOPY TO MEET FIRE CODE. SPECIALITY UG O TO BE COONTROLLL D BY A TIME C�LOCILLUMINATION AND O PAINT ALL EXPOSED HVAC, SPRINKLER PIPING CONDUIT AND STRUCTURAL JOI (ROOM 1 STS, TO 13). INCLUDE UNDERSIDE OF CEIUNO DECK, IN NO CEIUNO AREAS PROVIDE EMERGENCY UGHTING AS REQUIRED PER CODE- INSTALL BATTERY OPERATED TYPE UGTING IN THE SALES AREA LEADING TO THE EXIT. PROVIDE GROMMET OR TRIM AT ALL CEIUNG PENETRATIONS FOR FIXTURES. IF A FIRE SPRINKLER SYSTEM IS REQUIRED BY LOCAL CODE GENERAL CONTRACTOR TO PROVIDE SEMI - RECESSED SPRINKLER HEADS YW POLISHED CHROME ESCUTCHEONS. PROVIDE HEAD LOCATION LAYOUT FOR ARCHITECTS COORDINATION AND APPROVAL NOTE: SEE MECHANICAL DRAWINGS FOR SIZE. MECHANICAL UNDER SEPARATE PERMIT. LE.") atniann o - r - -_ ■ lT.r ire • •••••■. •■•■.•1•0•v 1 Mr MI WI PO ■� Mr•••■. : =ME s.— 1r -e'AFF AN CEILING 11°4T AFF T.O. CORNICE A T.O. GM SOFFIT 11441 f FLUORESCENT STRIP UGHT FIXTURE 5/8' GWB OSBORNE -HUME /EG1 EGGCRATE UGHT DIFFUSER T4 /1Z' AFF TEE SUPPORT SCALE: 314"= 1'-O"' 91/2' 3 "4' OPEN 1' 7-0" FACE OF SHELVING UNIT MERCH SOFFIT DETAIL REFLECTED CEILING PLAN "to SCALE: 1/4"=1 • LIGHTING SCHEDULE 11 64 #-C 'y 464 • ey_s-./-t.c e-ess 4 - t2 OUTLINE OF 5 GWB SOFFIT 0 T -01/2'AF.F. GYVE CEIUNG ABOVE SHELVING fa 12-o' • 1 2 4 KARREMAN + ASSOCIATES I a rchitecture OUTUNE OF FOAM CORNICE 3 0 • 1 s 231 Gowen Place NW Bainbridge Island Washington 98110 tel / fax 206 842 1253 e -mail fronkQkorreman.com ARCHITECTS STAMP CONSULTANTS: . REFLECTED CEIUNG PLAN ELo7- 37? SCALE: W =1 ISSUE DATE: 7/207 REVISIONS: oor�srAUCnor� SET A3.0 w CO 00 0 0) Location • Description Aimed Watts per f 2 of per H Area N el (or If for perimeter) Allowed Watts x le (or x11) Covered Peddng (standard pdrlt) ` 02 WAt? 2260.0 4520.0 Covered Paddng (reflective 0 New Building 0 Addison -, P 0.3W/ft' Refer to WSEC Section 1513 for controls and commissioning r (Compliance Option 1 Open Parking Alteration Exceptions D 0.2 Wltt Outdoor Areas 0.2 Wl11 Bldg. (by facade) 0.25 WAR Bldg. (by lam)' 7.5 WM NEVE OF DOOM= 11KO.GALE se mood are sew ei cum Wong r r o F *If ONE NM at MS aryl Afton gems - ACOOKirax los Doman Pari 1FE WAS N O MED HERM� AS A! ifsa�tENT OF P� a 111E sisomm1r OF M► OIUE 369, SIC. /WO IS ROT 10 SE USED. 1w MOLE at IN PM% FOR MY OwElt PR OdEl;T =IOUr if tuner •111011 AltolI OF Fly a comarL M/ emecome, sec Location (floorhoom no.) Occupancy Description Mowed Watts per il " Area 11 ft Marred x Area !?norm►, ma !4144 MUM 8101 2.00 2260.0 4520.0 Project Description 0 0 New Building 0 Addison -, P Plans A Refer to WSEC Section 1513 for controls and commissioning r (Compliance Option 1 10 O Lighting Power Allowance 0 s Analyals (See Qusification Chedt st ( over). Indicate PresaipYMe & LPA spaces clearly on plans.) Alteration Exceptions D D No s are � made to the Ong Project Info P Prc 111sn► A* sou:sesa me D Dde 8/7/2007 TuC 17100 S00 onsa PAl11OaY, TW ST SPACa M112 F For � Use !?norm►, ma !4144 APPS Name: ARRAS= • AssOClAtzs APpIC a ll antAddress: s31 oml ? Z MM a&nmaIDOe I4, me - APPIteld 2 206 - 442 -12s3 ■ Project Description 0 0 New Building 0 Addison -, P Plans A Refer to WSEC Section 1513 for controls and commissioning r (Compliance Option 1 10 O Lighting Power Allowance 0 s Analyals (See Qusification Chedt st ( over). Indicate PresaipYMe & LPA spaces clearly on plans.) Alteration Exceptions D D No s are � made to the Ong ...WV fv.IM.. twI II V.i..W .•V.M,..I.YY..MV• ami....j.L ' '1!W' ... -- murscv,a 113 1 - COMP Ct 1W t? OI MOLL 1014321. 6 26.0 156.0 10111W011 113 s - CpMACT fLUOS MOAN? . 12 50.0 600.0 OIL COMM M Dar 114 L COMM 1LOOaiacsue 1tMd18sm CAN • 2 17.5 35.0 sT1 As0. 115 L - COMIC? noses r 111011110113118 et1s CAM 1 17.5 17.5 Rtrse i 11s J - 1Mmscm MALL BRACm 1 60.0 60.0 115511 116 L • coiner 1rJltORtaCOUT RIMS= CAM 1 17.5 17.5 81s?104 116 J - nrrAunascnrr MALL MAO= 1 60.0 60.0 Total Proposed Was may not exceed Total Mowed Waits for Wertor Total Proposed Watts 4496.0 FEED FROM PANEL 1 - 112 PANEL SCHEDULE 200 AMP .CCT. BwCRBRIM_ - VOLT - AMPERES CCT. B DESCRIPTION PHASE DESCRIPTION - AMP POLE CCT. A B C CCT. POLE AMP 1 + 3 HVAC • 5040 10080 5040 HVAC ' 3 2 3 HVAC 5040 10080 3010 HVAC 4 7 , 3 HVAC 5040 10080 5040 HVAC 6 HVAC 5040 5400 360 ROOF OUTLETS 1 20 8 9 _ HVAC _ 5040 5040 . 10 11 HVAC 5040 5040 12 13 20 7 EF 1 187 187 14 15 3 HVAC 5040 , 5040 16 17 HVAC . 5040 . _ , 18 ' 19 HVAC 5040 , 5040 5040 ` 20 21 . 23 • 22 25 24 27 26 _ 28 31 30 33 32 29 35 . 34: 37 - 36 39 _ 38 40 41 42 PHASE VIA ' 20707 20160 20160 61027 VA TOTAL AMPS . ___ . 169.5 AMPS - - - Number of Walls/ Watts Location Fixture Description Factures Fbdire Proposed 4 _ Total Proposed Watts may not exceed Total Mowed Watts for Exterior Total Proposed Watts 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 PANEL L -112 A 200 AMP CCT. BR CR. DESCRIPTION AMP POLE 20 1 OFFICE DED OUTLET 20 1 MESSAGE OUTLETS 1 OFFICE DED OUTLET 1 OFFICE DED OUTLET 20 1 SIGN 20 20 20 20 20 20 20 20 20 30 30 30 1 FACIAL / LOBBY REC 1 FRONT OES*( DED 1 FRONT DESK DEO 1 FRONT DESK DED 1 MANACURE TRACK 1 MANACURE TRACK 1 I MANACURE SCONCE 2 HOT WATER 1 LITES EAST 1 WORK / BATH UTES HOT WATER 2 HOT WATER 30 HOT WATER PHASE WA TOTAL AMPS FEED FROM PANEL SCHEDULE 2 4 6 8 10 12 14 16 18 22 24 26 28 30 32 34 36 38 40 42 �_, VOLT- AMPERES CCT. BRIM PHASE DESCRIPTION CCT. 1200 A B C CCT. potE AMP _ 1200 2460 , 1260 OFFICE AREA REC 1 20 1200 1740 540 WORK IiM REC 1 20 20 20 1200 1560 360 WORK RM REC 1 20 720 1620 900 PEDICURE BATH 720 1 20 1920 FACIAL 1 1 20 1080 764 2564 2160 1080 MESSAGE REC 1 20 1200 2280 1080 FRONT DESK 1 20 1200 2460 1 260 FACIAL REC 1 20 1200 1740 540 FACIAL REC 1 20 1950 3310 1360 FACIAL LIGHTS 1 20 1950 3310 1360 FACIAL LIGHTS 1 20 156 _ 1231 1075 HALLWAY LIGHTS 1 20 1800 RETAIL TRACK 1 301 1431 1130 RECEPTION UTES 2500 3103 603 RETAIL UTES 1 20 2500 2500 2500 2500 2500 2500 14734 13361 12294 40389 VA 112 amps NOTEHVAC UNITS INSTALLATION AND CONNECTION TO PANEL B IS BY OTHERS_ • . 4 200sw•lwivbn 310,110rreddria1 Energy Cods Cas•lime Fa*s Maximum Allowed Lighting Wattage { Interio r 3: 13- -0 'over) - document al exceptions on form LTG -LPA RHJ-1 TO BE INSTAIED UNDER f SHELL CON1RACT (Tw.) 2004 State Nonresidential Code Farm Lighting Summary LTG -SUM Total Mowed Watts l 4520. 0 Notes: 1. Use manufackrers fated maximum Input wattage. For herd -wired ball ash only. the default table in the NREC Technical Reference Manual may also be used 2. klctude exit tights unless less than Swath per fixture. --- Proposed Lighting Wattage (Interior) 3. List al llxbrea• For exeelpt X not exoeglen and leave WalW vdlre b+aak. Location poor/room no.) roses 1ou 100 R1CaPTIO41 100 AaCEPTIOM 100 A PAIL 101 RETAIL 101 Fixt re Description A/a - s. LI11 VOL ?AGa 1111C1 L - C01II CT PW0ftsCI112 PECESSZO CAM A/a - 15• LIMA V0ltsOM Tau= T - 3 3•11011 MID?a SCRIP PLootzsaorr :emu. 101 - 2. SARA0R MITI 8121V 17.00820Cart MASSAGE 102 Is 103 .7 - 1MCAMCIcpT MALL MAAC11Et J - IMc iressct MALL IPOCAET bowsaws 104 J - 111CAIMMSC1241. MALL 88AcC4? CORRIDOR 105 00•MIDOR 105 COaaIDOR 105 FACIAL 107 FACIAL 107 L - COMPACT 119011184=2 RDcEs$ CAM 1/8 - 4 • LAIC 1014349Z TRACK v - 4• mamas MALL lalmt PWO0MSCxMT tail - 4• Lela VDrasea neck 1 - cesa cT 21101118CO.T MALL EAacw•r FACIAL 105 VAclAL 110 FACIAL 110 - oarpsCt Enosescswe MALL $AACAET Ala - 4• LONE VOIRMG• TRACT - Coea>AC- 47•01 18012/2 MALL HAIR ? FACIAL 108 P1C1&L 108 TACIAL 105 O/8 - 4• Lunt TOLeAGS TsAca 1 - COQACT 67.48711342212 MALL BARCIMT a/a - 4• mat VOLTAGe mar FACIAL 111 1/3 - 4• Lnoc VOZSAOE TRACE FACIAL 111 =REM 112 1 - COMPACT tutus? Starr MOLL aaAc ET I F - a• x 4• seserwcz 2 RAMP FLCOaasC8lr? Number of Fbctures 3 5 4 15 4 3 2 2 10 4 3 4 2 2 4 2 4 2 4 3 Watts! Fixture 60.0 50.0 17.5 50.0 17.0 Proposed 180.0 250.0 70.0 750.0 68.0 17.0 51.0 60.0 120.0 60.0 120.0 60.0 120.0 17.5 50.0 40.0 50.0 14.0 175.0 200.0 120.0 200.0 28.0 50.0 14.0 50.0 200.0 28.0 200.0 14.0 50.0 14.0 28.0 200.0 28.0 50.0 200.0 14.0 28.0 62.0 186.0 118.4e411ey2005 I R1tY3 i S f� III ti 1 i r:. lr , ROOF PLAN • HVAC SCALE: 1y4 = a' • Maximum Allowed Li tin Wattage {Exterior 1_ Choose either the facade area or 81e perimeter method. but not both) Total Mowed Watts Use rntgr tided mexinun input wattage. For foetuses with 1R� Pro pose Lighting Wattage (Exterior) the default table in the NREC Technical Reference Manual may also be used. 1 PANEL A" 120/208 3 PHASE PANELS AND FEEDERS BY OTHERS HVAC FEEDERS BY OTHERS O PANEL b " A 120/208 3 PHASE • TENANT SPACE ELECTRICAL LOADING PANEL L -112 PANEL L -112 A TOTAL. LOAD 281.7 LOAD 61027 VA LOAD 40389 VA 101416 VA = 113281.7 AMPS AMPS X 125% = 352.125 AMPS 1 KARREMAN +ASSOCIATES 4rchitecture • 231 Gowen Place NW Bainbridge Island Washington 98110 fel / fax 206 842 1253 e - mail frankOkarrem an.com • ARCHITECTS STAMP CONSULTANTS: HV Engineering, Inc. Consulting Engineers . 7100 Linden Ave. N. Suite 1 Seattle, Washington. 98103 www. hvengineering. biz Phone: (288) 708 -9880 ROOF PLAN HVAC SCALE: 114` =1'-0' ISSUE DATE: 7/27107 REVISIONS: Paz: (Z06) 708 -t830 Q W � CC CC Q a- 0 CC � W c o E- W 00 Z U a) W I <t U F _ (Ni I- O J D V J T' -1 OOW co O I Y Q T VJ PERM sEr M2.0 ELO'1 39`t FEED FROM PANEL 1 - 112 PANEL SCHEDULE 200 AMP .CCT. BwCRBRIM_ - VOLT - AMPERES CCT. B DESCRIPTION PHASE DESCRIPTION - AMP POLE CCT. A B C CCT. POLE AMP 1 + 3 HVAC • 5040 10080 5040 HVAC ' 3 2 3 HVAC 5040 10080 3010 HVAC 4 7 , 3 HVAC 5040 10080 5040 HVAC 6 HVAC 5040 5400 360 ROOF OUTLETS 1 20 8 9 _ HVAC _ 5040 5040 . 10 11 HVAC 5040 5040 12 13 20 7 EF 1 187 187 14 15 3 HVAC 5040 , 5040 16 17 HVAC . 5040 . _ , 18 ' 19 HVAC 5040 , 5040 5040 ` 20 21 . 23 • 22 25 24 27 26 _ 28 31 30 33 32 29 35 . 34: 37 - 36 39 _ 38 40 41 42 PHASE VIA ' 20707 20160 20160 61027 VA TOTAL AMPS . ___ . 169.5 AMPS - - - Number of Walls/ Watts Location Fixture Description Factures Fbdire Proposed 4 _ Total Proposed Watts may not exceed Total Mowed Watts for Exterior Total Proposed Watts 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 PANEL L -112 A 200 AMP CCT. BR CR. DESCRIPTION AMP POLE 20 1 OFFICE DED OUTLET 20 1 MESSAGE OUTLETS 1 OFFICE DED OUTLET 1 OFFICE DED OUTLET 20 1 SIGN 20 20 20 20 20 20 20 20 20 30 30 30 1 FACIAL / LOBBY REC 1 FRONT OES*( DED 1 FRONT DESK DEO 1 FRONT DESK DED 1 MANACURE TRACK 1 MANACURE TRACK 1 I MANACURE SCONCE 2 HOT WATER 1 LITES EAST 1 WORK / BATH UTES HOT WATER 2 HOT WATER 30 HOT WATER PHASE WA TOTAL AMPS FEED FROM PANEL SCHEDULE 2 4 6 8 10 12 14 16 18 22 24 26 28 30 32 34 36 38 40 42 �_, VOLT- AMPERES CCT. BRIM PHASE DESCRIPTION CCT. 1200 A B C CCT. potE AMP _ 1200 2460 , 1260 OFFICE AREA REC 1 20 1200 1740 540 WORK IiM REC 1 20 20 20 1200 1560 360 WORK RM REC 1 20 720 1620 900 PEDICURE BATH 720 1 20 1920 FACIAL 1 1 20 1080 764 2564 2160 1080 MESSAGE REC 1 20 1200 2280 1080 FRONT DESK 1 20 1200 2460 1 260 FACIAL REC 1 20 1200 1740 540 FACIAL REC 1 20 1950 3310 1360 FACIAL LIGHTS 1 20 1950 3310 1360 FACIAL LIGHTS 1 20 156 _ 1231 1075 HALLWAY LIGHTS 1 20 1800 RETAIL TRACK 1 301 1431 1130 RECEPTION UTES 2500 3103 603 RETAIL UTES 1 20 2500 2500 2500 2500 2500 2500 14734 13361 12294 40389 VA 112 amps NOTEHVAC UNITS INSTALLATION AND CONNECTION TO PANEL B IS BY OTHERS_ • . 4 200sw•lwivbn 310,110rreddria1 Energy Cods Cas•lime Fa*s Maximum Allowed Lighting Wattage { Interio r 3: 13- -0 'over) - document al exceptions on form LTG -LPA RHJ-1 TO BE INSTAIED UNDER f SHELL CON1RACT (Tw.) 2004 State Nonresidential Code Farm Lighting Summary LTG -SUM Total Mowed Watts l 4520. 0 Notes: 1. Use manufackrers fated maximum Input wattage. For herd -wired ball ash only. the default table in the NREC Technical Reference Manual may also be used 2. klctude exit tights unless less than Swath per fixture. --- Proposed Lighting Wattage (Interior) 3. List al llxbrea• For exeelpt X not exoeglen and leave WalW vdlre b+aak. Location poor/room no.) roses 1ou 100 R1CaPTIO41 100 AaCEPTIOM 100 A PAIL 101 RETAIL 101 Fixt re Description A/a - s. LI11 VOL ?AGa 1111C1 L - C01II CT PW0ftsCI112 PECESSZO CAM A/a - 15• LIMA V0ltsOM Tau= T - 3 3•11011 MID?a SCRIP PLootzsaorr :emu. 101 - 2. SARA0R MITI 8121V 17.00820Cart MASSAGE 102 Is 103 .7 - 1MCAMCIcpT MALL MAAC11Et J - IMc iressct MALL IPOCAET bowsaws 104 J - 111CAIMMSC1241. MALL 88AcC4? CORRIDOR 105 00•MIDOR 105 COaaIDOR 105 FACIAL 107 FACIAL 107 L - COMPACT 119011184=2 RDcEs$ CAM 1/8 - 4 • LAIC 1014349Z TRACK v - 4• mamas MALL lalmt PWO0MSCxMT tail - 4• Lela VDrasea neck 1 - cesa cT 21101118CO.T MALL EAacw•r FACIAL 105 VAclAL 110 FACIAL 110 - oarpsCt Enosescswe MALL $AACAET Ala - 4• LONE VOIRMG• TRACT - Coea>AC- 47•01 18012/2 MALL HAIR ? FACIAL 108 P1C1&L 108 TACIAL 105 O/8 - 4• Lunt TOLeAGS TsAca 1 - COQACT 67.48711342212 MALL BARCIMT a/a - 4• mat VOLTAGe mar FACIAL 111 1/3 - 4• Lnoc VOZSAOE TRACE FACIAL 111 =REM 112 1 - COMPACT tutus? Starr MOLL aaAc ET I F - a• x 4• seserwcz 2 RAMP FLCOaasC8lr? Number of Fbctures 3 5 4 15 4 3 2 2 10 4 3 4 2 2 4 2 4 2 4 3 Watts! Fixture 60.0 50.0 17.5 50.0 17.0 Proposed 180.0 250.0 70.0 750.0 68.0 17.0 51.0 60.0 120.0 60.0 120.0 60.0 120.0 17.5 50.0 40.0 50.0 14.0 175.0 200.0 120.0 200.0 28.0 50.0 14.0 50.0 200.0 28.0 200.0 14.0 50.0 14.0 28.0 200.0 28.0 50.0 200.0 14.0 28.0 62.0 186.0 118.4e411ey2005 I R1tY3 i S f� III ti 1 i r:. lr , ROOF PLAN • HVAC SCALE: 1y4 = a' • Maximum Allowed Li tin Wattage {Exterior 1_ Choose either the facade area or 81e perimeter method. but not both) Total Mowed Watts Use rntgr tided mexinun input wattage. For foetuses with 1R� Pro pose Lighting Wattage (Exterior) the default table in the NREC Technical Reference Manual may also be used. 1 PANEL A" 120/208 3 PHASE PANELS AND FEEDERS BY OTHERS HVAC FEEDERS BY OTHERS O PANEL b " A 120/208 3 PHASE • TENANT SPACE ELECTRICAL LOADING PANEL L -112 PANEL L -112 A TOTAL. LOAD 281.7 LOAD 61027 VA LOAD 40389 VA 101416 VA = 113281.7 AMPS AMPS X 125% = 352.125 AMPS 1 KARREMAN +ASSOCIATES 4rchitecture • 231 Gowen Place NW Bainbridge Island Washington 98110 fel / fax 206 842 1253 e - mail frankOkarrem an.com • ARCHITECTS STAMP CONSULTANTS: HV Engineering, Inc. Consulting Engineers . 7100 Linden Ave. N. Suite 1 Seattle, Washington. 98103 www. hvengineering. biz Phone: (288) 708 -9880 ROOF PLAN HVAC SCALE: 114` =1'-0' ISSUE DATE: 7/27107 REVISIONS: Paz: (Z06) 708 -t830 Q W � CC CC Q a- 0 CC � W c o E- W 00 Z U a) W I <t U F _ (Ni I- O J D V J T' -1 OOW co O I Y Q T VJ PERM sEr M2.0 ELO'1 39`t - - - Number of Walls/ Watts Location Fixture Description Factures Fbdire Proposed 4 _ Total Proposed Watts may not exceed Total Mowed Watts for Exterior Total Proposed Watts 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 PANEL L -112 A 200 AMP CCT. BR CR. DESCRIPTION AMP POLE 20 1 OFFICE DED OUTLET 20 1 MESSAGE OUTLETS 1 OFFICE DED OUTLET 1 OFFICE DED OUTLET 20 1 SIGN 20 20 20 20 20 20 20 20 20 30 30 30 1 FACIAL / LOBBY REC 1 FRONT OES*( DED 1 FRONT DESK DEO 1 FRONT DESK DED 1 MANACURE TRACK 1 MANACURE TRACK 1 I MANACURE SCONCE 2 HOT WATER 1 LITES EAST 1 WORK / BATH UTES HOT WATER 2 HOT WATER 30 HOT WATER PHASE WA TOTAL AMPS FEED FROM PANEL SCHEDULE 2 4 6 8 10 12 14 16 18 22 24 26 28 30 32 34 36 38 40 42 �_, VOLT- AMPERES CCT. BRIM PHASE DESCRIPTION CCT. 1200 A B C CCT. potE AMP _ 1200 2460 , 1260 OFFICE AREA REC 1 20 1200 1740 540 WORK IiM REC 1 20 20 20 1200 1560 360 WORK RM REC 1 20 720 1620 900 PEDICURE BATH 720 1 20 1920 FACIAL 1 1 20 1080 764 2564 2160 1080 MESSAGE REC 1 20 1200 2280 1080 FRONT DESK 1 20 1200 2460 1 260 FACIAL REC 1 20 1200 1740 540 FACIAL REC 1 20 1950 3310 1360 FACIAL LIGHTS 1 20 1950 3310 1360 FACIAL LIGHTS 1 20 156 _ 1231 1075 HALLWAY LIGHTS 1 20 1800 RETAIL TRACK 1 301 1431 1130 RECEPTION UTES 2500 3103 603 RETAIL UTES 1 20 2500 2500 2500 2500 2500 2500 14734 13361 12294 40389 VA 112 amps NOTEHVAC UNITS INSTALLATION AND CONNECTION TO PANEL B IS BY OTHERS_ • . 4 200sw•lwivbn 310,110rreddria1 Energy Cods Cas•lime Fa*s Maximum Allowed Lighting Wattage { Interio r 3: 13- -0 'over) - document al exceptions on form LTG -LPA RHJ-1 TO BE INSTAIED UNDER f SHELL CON1RACT (Tw.) 2004 State Nonresidential Code Farm Lighting Summary LTG -SUM Total Mowed Watts l 4520. 0 Notes: 1. Use manufackrers fated maximum Input wattage. For herd -wired ball ash only. the default table in the NREC Technical Reference Manual may also be used 2. klctude exit tights unless less than Swath per fixture. --- Proposed Lighting Wattage (Interior) 3. List al llxbrea• For exeelpt X not exoeglen and leave WalW vdlre b+aak. Location poor/room no.) roses 1ou 100 R1CaPTIO41 100 AaCEPTIOM 100 A PAIL 101 RETAIL 101 Fixt re Description A/a - s. LI11 VOL ?AGa 1111C1 L - C01II CT PW0ftsCI112 PECESSZO CAM A/a - 15• LIMA V0ltsOM Tau= T - 3 3•11011 MID?a SCRIP PLootzsaorr :emu. 101 - 2. SARA0R MITI 8121V 17.00820Cart MASSAGE 102 Is 103 .7 - 1MCAMCIcpT MALL MAAC11Et J - IMc iressct MALL IPOCAET bowsaws 104 J - 111CAIMMSC1241. MALL 88AcC4? CORRIDOR 105 00•MIDOR 105 COaaIDOR 105 FACIAL 107 FACIAL 107 L - COMPACT 119011184=2 RDcEs$ CAM 1/8 - 4 • LAIC 1014349Z TRACK v - 4• mamas MALL lalmt PWO0MSCxMT tail - 4• Lela VDrasea neck 1 - cesa cT 21101118CO.T MALL EAacw•r FACIAL 105 VAclAL 110 FACIAL 110 - oarpsCt Enosescswe MALL $AACAET Ala - 4• LONE VOIRMG• TRACT - Coea>AC- 47•01 18012/2 MALL HAIR ? FACIAL 108 P1C1&L 108 TACIAL 105 O/8 - 4• Lunt TOLeAGS TsAca 1 - COQACT 67.48711342212 MALL BARCIMT a/a - 4• mat VOLTAGe mar FACIAL 111 1/3 - 4• Lnoc VOZSAOE TRACE FACIAL 111 =REM 112 1 - COMPACT tutus? Starr MOLL aaAc ET I F - a• x 4• seserwcz 2 RAMP FLCOaasC8lr? Number of Fbctures 3 5 4 15 4 3 2 2 10 4 3 4 2 2 4 2 4 2 4 3 Watts! Fixture 60.0 50.0 17.5 50.0 17.0 Proposed 180.0 250.0 70.0 750.0 68.0 17.0 51.0 60.0 120.0 60.0 120.0 60.0 120.0 17.5 50.0 40.0 50.0 14.0 175.0 200.0 120.0 200.0 28.0 50.0 14.0 50.0 200.0 28.0 200.0 14.0 50.0 14.0 28.0 200.0 28.0 50.0 200.0 14.0 28.0 62.0 186.0 118.4e411ey2005 I R1tY3 i S f� III ti 1 i r:. lr , ROOF PLAN • HVAC SCALE: 1y4 = a' • Maximum Allowed Li tin Wattage {Exterior 1_ Choose either the facade area or 81e perimeter method. but not both) Total Mowed Watts Use rntgr tided mexinun input wattage. For foetuses with 1R� Pro pose Lighting Wattage (Exterior) the default table in the NREC Technical Reference Manual may also be used. 1 PANEL A" 120/208 3 PHASE PANELS AND FEEDERS BY OTHERS HVAC FEEDERS BY OTHERS O PANEL b " A 120/208 3 PHASE • TENANT SPACE ELECTRICAL LOADING PANEL L -112 PANEL L -112 A TOTAL. LOAD 281.7 LOAD 61027 VA LOAD 40389 VA 101416 VA = 113281.7 AMPS AMPS X 125% = 352.125 AMPS 1 KARREMAN +ASSOCIATES 4rchitecture • 231 Gowen Place NW Bainbridge Island Washington 98110 fel / fax 206 842 1253 e - mail frankOkarrem an.com • ARCHITECTS STAMP CONSULTANTS: HV Engineering, Inc. Consulting Engineers . 7100 Linden Ave. N. Suite 1 Seattle, Washington. 98103 www. hvengineering. biz Phone: (288) 708 -9880 ROOF PLAN HVAC SCALE: 114` =1'-0' ISSUE DATE: 7/27107 REVISIONS: Paz: (Z06) 708 -t830 Q W � CC CC Q a- 0 CC � W c o E- W 00 Z U a) W I <t U F _ (Ni I- O J D V J T' -1 OOW co O I Y Q T VJ PERM sEr M2.0 ELO'1 39`t 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 PANEL L -112 A 200 AMP CCT. BR CR. DESCRIPTION AMP POLE 20 1 OFFICE DED OUTLET 20 1 MESSAGE OUTLETS 1 OFFICE DED OUTLET 1 OFFICE DED OUTLET 20 1 SIGN 20 20 20 20 20 20 20 20 20 30 30 30 1 FACIAL / LOBBY REC 1 FRONT OES*( DED 1 FRONT DESK DEO 1 FRONT DESK DED 1 MANACURE TRACK 1 MANACURE TRACK 1 I MANACURE SCONCE 2 HOT WATER 1 LITES EAST 1 WORK / BATH UTES HOT WATER 2 HOT WATER 30 HOT WATER PHASE WA TOTAL AMPS FEED FROM PANEL SCHEDULE 2 4 6 8 10 12 14 16 18 22 24 26 28 30 32 34 36 38 40 42 �_, VOLT- AMPERES CCT. BRIM PHASE DESCRIPTION CCT. 1200 A B C CCT. potE AMP _ 1200 2460 , 1260 OFFICE AREA REC 1 20 1200 1740 540 WORK IiM REC 1 20 20 20 1200 1560 360 WORK RM REC 1 20 720 1620 900 PEDICURE BATH 720 1 20 1920 FACIAL 1 1 20 1080 764 2564 2160 1080 MESSAGE REC 1 20 1200 2280 1080 FRONT DESK 1 20 1200 2460 1 260 FACIAL REC 1 20 1200 1740 540 FACIAL REC 1 20 1950 3310 1360 FACIAL LIGHTS 1 20 1950 3310 1360 FACIAL LIGHTS 1 20 156 _ 1231 1075 HALLWAY LIGHTS 1 20 1800 RETAIL TRACK 1 301 1431 1130 RECEPTION UTES 2500 3103 603 RETAIL UTES 1 20 2500 2500 2500 2500 2500 2500 14734 13361 12294 40389 VA 112 amps NOTEHVAC UNITS INSTALLATION AND CONNECTION TO PANEL B IS BY OTHERS_ • . 4 200sw•lwivbn 310,110rreddria1 Energy Cods Cas•lime Fa*s Maximum Allowed Lighting Wattage { Interio r 3: 13- -0 'over) - document al exceptions on form LTG -LPA RHJ-1 TO BE INSTAIED UNDER f SHELL CON1RACT (Tw.) 2004 State Nonresidential Code Farm Lighting Summary LTG -SUM Total Mowed Watts l 4520. 0 Notes: 1. Use manufackrers fated maximum Input wattage. For herd -wired ball ash only. the default table in the NREC Technical Reference Manual may also be used 2. klctude exit tights unless less than Swath per fixture. --- Proposed Lighting Wattage (Interior) 3. List al llxbrea• For exeelpt X not exoeglen and leave WalW vdlre b+aak. Location poor/room no.) roses 1ou 100 R1CaPTIO41 100 AaCEPTIOM 100 A PAIL 101 RETAIL 101 Fixt re Description A/a - s. LI11 VOL ?AGa 1111C1 L - C01II CT PW0ftsCI112 PECESSZO CAM A/a - 15• LIMA V0ltsOM Tau= T - 3 3•11011 MID?a SCRIP PLootzsaorr :emu. 101 - 2. SARA0R MITI 8121V 17.00820Cart MASSAGE 102 Is 103 .7 - 1MCAMCIcpT MALL MAAC11Et J - IMc iressct MALL IPOCAET bowsaws 104 J - 111CAIMMSC1241. MALL 88AcC4? CORRIDOR 105 00•MIDOR 105 COaaIDOR 105 FACIAL 107 FACIAL 107 L - COMPACT 119011184=2 RDcEs$ CAM 1/8 - 4 • LAIC 1014349Z TRACK v - 4• mamas MALL lalmt PWO0MSCxMT tail - 4• Lela VDrasea neck 1 - cesa cT 21101118CO.T MALL EAacw•r FACIAL 105 VAclAL 110 FACIAL 110 - oarpsCt Enosescswe MALL $AACAET Ala - 4• LONE VOIRMG• TRACT - Coea>AC- 47•01 18012/2 MALL HAIR ? FACIAL 108 P1C1&L 108 TACIAL 105 O/8 - 4• Lunt TOLeAGS TsAca 1 - COQACT 67.48711342212 MALL BARCIMT a/a - 4• mat VOLTAGe mar FACIAL 111 1/3 - 4• Lnoc VOZSAOE TRACE FACIAL 111 =REM 112 1 - COMPACT tutus? Starr MOLL aaAc ET I F - a• x 4• seserwcz 2 RAMP FLCOaasC8lr? Number of Fbctures 3 5 4 15 4 3 2 2 10 4 3 4 2 2 4 2 4 2 4 3 Watts! Fixture 60.0 50.0 17.5 50.0 17.0 Proposed 180.0 250.0 70.0 750.0 68.0 17.0 51.0 60.0 120.0 60.0 120.0 60.0 120.0 17.5 50.0 40.0 50.0 14.0 175.0 200.0 120.0 200.0 28.0 50.0 14.0 50.0 200.0 28.0 200.0 14.0 50.0 14.0 28.0 200.0 28.0 50.0 200.0 14.0 28.0 62.0 186.0 118.4e411ey2005 I R1tY3 i S f� III ti 1 i r:. lr , ROOF PLAN • HVAC SCALE: 1y4 = a' • Maximum Allowed Li tin Wattage {Exterior 1_ Choose either the facade area or 81e perimeter method. but not both) Total Mowed Watts Use rntgr tided mexinun input wattage. For foetuses with 1R� Pro pose Lighting Wattage (Exterior) the default table in the NREC Technical Reference Manual may also be used. 1 PANEL A" 120/208 3 PHASE PANELS AND FEEDERS BY OTHERS HVAC FEEDERS BY OTHERS O PANEL b " A 120/208 3 PHASE • TENANT SPACE ELECTRICAL LOADING PANEL L -112 PANEL L -112 A TOTAL. LOAD 281.7 LOAD 61027 VA LOAD 40389 VA 101416 VA = 113281.7 AMPS AMPS X 125% = 352.125 AMPS 1 KARREMAN +ASSOCIATES 4rchitecture • 231 Gowen Place NW Bainbridge Island Washington 98110 fel / fax 206 842 1253 e - mail frankOkarrem an.com • ARCHITECTS STAMP CONSULTANTS: HV Engineering, Inc. Consulting Engineers . 7100 Linden Ave. N. Suite 1 Seattle, Washington. 98103 www. hvengineering. biz Phone: (288) 708 -9880 ROOF PLAN HVAC SCALE: 114` =1'-0' ISSUE DATE: 7/27107 REVISIONS: Paz: (Z06) 708 -t830 Q W � CC CC Q a- 0 CC � W c o E- W 00 Z U a) W I <t U F _ (Ni I- O J D V J T' -1 OOW co O I Y Q T VJ PERM sEr M2.0 ELO'1 39`t