Loading...
HomeMy WebLinkAboutPermit EL07-405 - JAMBA JUICEJAMBA JUICE 17100 SOUTHCENTER PY SUITE 104 ELO7-405 Parcel No.: 2623049081 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: MICHAEL PASICH Address: 7056 S 220 ST , KENT WA Contractor: Name: SEA TAC ELECTRIC INC Address: 7056 S 220TH ST , KENT WA Contractor License No: SEATAEI077RW DESCRIPTION OF WORK: INSTALL (1) 200 AMP PANEL AND CONNECT HVAC UNIT Value of Electrical: $7,640.00 Type of Fire Protection: Permit Center Authorized Signature: Signature: 7 Print Name: v /A) 04/19,4 Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17100 SOUTHCENTER PY TUKW JAMBA JUICE 17100 SOUTHCENTER PY, STE 104 , TUKWILA WA WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE WA Electrical Service provided by: PUGET SOUND ENERGY L, ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 872 -5553 Phone: Expiration Date: 12/16/2007 EL07 -405 08/31/2007 02/27/2008 Fees Collected: $266.50 National Electrical Code Edition: 2005 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perform- ce of work. I am authorized to sign and obtain this electrical permit. Date: AW 5/ Zoo 7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL07 -405 Printed: 08 -31 -2007 Parcel No.: 2623049081 Address: 17100 SOUTHCENTER PY TUKW Suite No: Tenant: JAMBA JUICE 1: * * *F'i,FCTRICAL * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: EL07 -405 Status: ISSUED Applied Date: 08/17/2007 Issue Date: 08/31/2007 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. doc: Cond -Elec Date: SC-Pt // .Jd 7� EL07 -405 Printed: 08 -31 -2007 CITY OF TUKWILA Community Develop 'nt Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwilawaus ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: `.•'"(P1-1." —TOV Site Address: 11106 Spt,ktNc n Tele_ Suite Number: 1 0-I Floor: Tenant Name: n An464 z►nilr New Tenant: [1 Yes ❑..No Property Owners Name: 'AO IC1 T FEe.1 Mailing Address: 4 t I i -tt''` 'P . 5E CONTACT PERSON - Who do we contact when your permit 1a ready to be issued Name:1AILI- 119e'L ?ASV Mailing Address: 'I 05L, 7,2.0 } j E -Mail Address: L-1ICE P e 5E171 - elec r tZ - eoYr1 ELECTRICAL CONTRACTOR INFORMATION Company Name: SEri"rl9 c EtC- -T t2 r•� ; Mailing Address: '705 g 7 j o+` - Contact Person: L4 et_ p,' is - E-mail . Address: mw-EP TP�LEtEreTle;+t e-av7-7 Contractor Registration Number: `" v1E X45 - 71 Valuation of Project (contractor's bid price): $ '1U 40 .00 Scope of Work (please provide detailed information): I kisTVA IA (► Z twin e n h , h -'. '. i.4L IAA i t\ Will service be altered? VI Yes ❑ No Type of Use: t^.nm m Fors _i.°rz_ Type of work: New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: Puget Sound Energy ❑ Seattle City Light H:1ApplitationsTomw Applications On Iine14 -2007. Elechiee Permit Apptiationdoc e>, Electrical Pe ;t No. t D Project No. (For office use only) e - cc∎1tke City 1.ASA State SCOle Zip Day Telephone: Z�3 - 7511_- 5 t5 5 IG -vtT t A)11 9 R032.— City State Zip Fax Number: Z .53 - $7 Z • 4412-- t-F-4 t veg. `Ii 37 City State Zip Day Telephone: Z 5 3 8 7Z-- .55. Fax Number: Zt:5 3 37 2.- 4a t Zr Expiration Date: 1 Z-10 Adding more than 50 amps? Yes ❑ No ❑ Remodel ❑ Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ,3 • New single family dwellings 5140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings 575.00 ea ❑ Low voltage systems (alarm, furnace thermostat) 555.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration 575.00 (no added/altered circuits) ❑ Service change with added/altered circuits 575.00 number of added circuits 510.00 ea ❑ Circuits added/altered without service change 550.00 (up to 5 circuits) ❑ Circuits added/altered without service change 550.00 (6 or more circuits) 57.00 ea ❑ Meter /mast repair 565.00 ❑ Low voltage systems 555.00 (alarm, furnace thermostat) MULTI AMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) 558.00 ❑ Temporary service (generator) S75.00 ❑ Manufactured/mobile home service 580.00 (excluding garage or outbuilding) ❑ Carnivals 575.00 Number of concessions S10.00 ea I PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. $UILDING OWNER OR ELECTRICAL CONTRACTOR: Mailing Address: 70 5L I Date Application Accepted: M j H:Mpplieatio Fon . Applications on tinel4 -2007 • Electrical Permit Applieetiondoe bb Date: 1 Day Telephone: 7-5" 7i1 Zt S5 5 3 1U�rtT w■c} City State c &t Z zip Date Application Expires: Staff Initials: (I I Page 2 of 2 vs....enrInwron no, RECEIPT NO: R07 -01732 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Initials: JEM Payment Date: 08/17/2007 User ID: 1165 Total Payment: 628.50 Payee: SEA -TAC ELECTRIC, INC. SET ID: S000000829 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount EL07 -403 246.00 EL07 -404 58.00 EL07 -405 266.50 EL07 -406 58.00 TOTAL: 628.50 SET RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 8665 628.50 TOTAL: 628.50 ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES Account Code Current Pmts 000.322.101.00.0 526.00 000.345.832.00.0 102.50 TOTAL: 628.50 Project: Tit .."1 4 ( 71,f 1 c- .r- Type of Inspection: c /0 0 Address: I U r) •xi7riehvr4& Date Called: //' S- d 7 Special Instructions: Date Wanted: //. 9-U r7 a.m. ,. p.m. Requester: 5'9 9 Phone No: ` /v6 -,Wei-2 COMMENTS: 2K Inspecj6r: ❑s58. 'Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit ` /U5 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISIONS 8- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 - 3670 2 Approved per applicable codes. Corrections required prior to approval. EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid i3t 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. r7112 r UErriy )7 Date: pi -v \&_ Project: —J.A41 (3.4 R ra i C Type of Inspection: Address: ) -) 1 00 S ou 1A•ttof Date Called: / / ' 9 -07 Special Instructions: Date Wanted: A 7P. Requester: 5 9 59 Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 0 14 3 C Inspect%) Y Date: / 9-()J Ej $58.00 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: IDate: DEPARTMENTS: ��G Buil ing Diiri� ion Public Works Comments: Approved ❑ Notation: APPROVALS OR CORRECTIONS: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL07 -405 DATE: 08 -17 -07 PROJECT NAME: JAMBA JUICE SITE ADDRESS: 17100 SOUTHCENTER PY, STE 104 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ TUES/THURS ROUTING: Please Route 14 Structural Review Required REVIEWER'S INITIALS: Approved with Conditions C ❑ Permit Coordinator n DUE DATE: 08-21-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 09-18-07 Not Approved (attach comments) ❑ DATE: Planning Division n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License SEATAEI077RW Licensee Name SEA TAC ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 601510212 Ind. Ins. Account Id PRESIDENT Business Type CORPORATION Address 1 7056 S 220TH ST Address 2 City KENT County KING State WA Zip 98032 Phone 2538725553 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/16/1993 Expiration Date 12/16/2007 Suspend Date Separation Date Parent Company Previous License SEATAEC131QC Next License Associated License HARGRT *974CD Business Owner Information Name Role Effective Date Expiration Date HARGREAVES, TOM AGENT 12/17/1993 HARGREAVES, TOM PRESIDENT 12/17/1993 HARGREAVES, Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Master Electrician Information License Name Status HARGRT *974CD HARGREAVES, TOM ACTIVE https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= SEATAEI077RW 08/31/2007 PANEL: L -104 - A PANEL VOLTAGE: 120/208 3 0 4 W CIRCUIT CODE: blank or N : NON — CONTINUOUS BUS: 200 AMP ' L : LONG — CONTINUOUS DATE 08/13/2007 11ME MAINS: MAIN BREAKER R : DEMANDABLE RECEPTACLES JOB: SOUTHCENTER SQUARE AIC RATING: 11,000 K : KITCHEN NO. OF EQUIPMENT: 0 CKT NO 3000 dlal 310d LOAD DESIGNATION CONNECTED VA LOAD DESIGNATION &Il 310d 3000 CKT NO DESCRIPTION N R L OA O B O C AB C OA 08 O C N R L DESCRIPTION . 0 % % Ar/ f, 0 % %l o '�� � 0 ,,, Ill ,,, 0 % %�� - 2 2 1 60 . f o X� 0 A 576 D % 5760 % 0 f jfl A lm % 0 A %/' 4 3 4 „i, ,,,, m ill , �„ iiif // AA � ,,,, 5760 0 6 5 6 5 3 8 7 5760 f 0 f/ 0 0 8 7 60 9 f � o � 0 % / / / / / //A 0 10 9 10 11 0 � // / / /�� f���f� 0 12 11 3 12 . 0 0 0 / /////, 0 A, 0 0 �� 14 13 14 f 0 0 0 %' / / / / / /// . 16 1 fi 15 IIII 18 17 // � // � 0 0 18 17 III , ,, 0 % 20 19 20 0 0 ��� 21 . 0 , /// 0 /// 22 21 24 � // /� f ) H I 0 /,,, %� 0 / / // 0 0 HE 24 23 0 /////l 0 � 0 26 25 26 25 , �, V: f 28 28 27 0 0 30 30 29 31 0 0 32 31 32 33 - A 34 33 / / / / /// % / / / / / 0 34 36 35 0 / /////, 0 0 %' / / / / / /��f� � 0 ,�„ 38 37 0 ri /A. 38 40 39 o %' / / / / / / // „� 0 42 41 39 ��11 0 ��� / / /f / 0 % / / / / /���� PANEL NOTES: PHASE TOTALS 0 A: 0 0B: 0 0C: 0 TOTAL CONNECTED VA 0 CONNECTED VA (CODE N) 0 CONNECTED VA (CODE L) 0 CONNECTED VA (CODE R) 0 (CODE L) X 25% 0 TOTAL " L " + TOTAL " N " 0 PANEL DEMAND KVA 0 AMPS W1111/LCL 0 PANEL: L-104 PANEL VOLTAGE: 120/208 3 0 4 W CIRCUIT CODE blank or N : NON — CONTINUOUS BUS: 200 AMP L : LONG — CONTINUOUS DATE 08/13/2007 11ME: MAINS: MAIN BREAKER R : DEMANDABLE RECEPTACLES JOB: SOUTHCENTER SQUARE AIC RATING: 11,000 K : KITCHEN NO. OF EQUIPMENT: 0 CKT NO 3000 dldl 310d LOAD DESIGNATION CONNECTED VA LOAD DESIGNATION dldI 310d 3000 CKT NO DESCRIPTION N R L OA O B o C AB C OA 0 B 0 C N R L DESCRIPTION 5760 :760 2 1 60 3 ROOFTOP UNIT #1 576 D % 5760 % 0 f jfl A lm % 0 A %/' 4 „i, ,,,, m ill , �„ iiif // AA � ,,,, 5760 6 5 3 5760 f 0 f/ 8 7 60 9 ROOFTOP UNIT #2 0 10 0 12 11 3 13 0 / /////, 0 A, 0 0 �� 14 f 0 %' / / / / / /// . 16 15 18 17 0 0 % � f 20 19 21 . 0 22 24 23 / / // 0 HE 0 /////l 0 � 26 25 0 28 27 IIIII 0 30 29 31 0 0 32 33 - A 0 / / / / /// 34 36 35 % f % / / / / / //r , o o j� ,,,, 0 � 0 ,�„ 37 0 0 � 38 o %' / / / / / / // 40 39 ��11 ��� / / /f / 0 . 42 41 PANEL NOTES: PHASE TOTALS 0 A : 11520 0 B: 11520 0 C: 11520 TOTAL CONNECTED VA 34560 CONNECTED VA (CODE N) 34560 CONNECTED VA (CODE L) 0 CONNECTED VA (CODE R) 0 (CODE L) X 25% 0 TOTAL "L" i- TOTAL "N" 34560 PANEL DEMAND KVA 34.56 AMPS WITH /LCL 96.00 JBOX FOR FUTURE SIGN TYPICAL OF 2 LOCATIONS FURNI ' • AND INSTALL POWER AND DATA CONDU 'OM THE UNITS THROUGH ROOF AND STUBB WITHIN THE PREMISES DIRECTLY BELOW THE U4t1TS. TENANT WILL INSTALL ELECTRICAL YAM �CONNECIIONS AND MISSION THE U 200A 120/208V PANEL FROM EXISTING 800A SERVICE REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC y AUG 21 2 + + + + + + + + + + + + + + + + + + + + + + + + + -h + t + + + + + + + + + + + + + + + + + + + + �- -►- + + + + + + + + + + + + + r + + + + + + + + + + + + + + + + + + + + + + 01 A3.1 M.E.P. FLOOR PLAN SCALE: 1/8"=1'-0" Public Works, Building Division PERMIT NUMBER 07 APIxtor RECEIVED CITY OF TUKvn'I Auu 1 / 'Cu)/ I'EH4T CENTER V , ■ ()P1L 4 FILE COPY ME OPT Permit N. BY —7 Datez _ 5 g d LANDLORD WORK JAMBA JUICE SOUTHCENTER SQUARE 17100 SOUTHCENTER PARKWAY TUKWILA, WA Plan review approval t3 subject to errors and omit Approval c? c3nstruc io m documents does not authorize the violation cf 4:y ac speed code or ordinancy. Reo1* of approved nz ::1 Cc;..r end nd;tiorts is acknotvledged; ay of Tukwila 71, BUILDING DIVISION (REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions w 11 require a new plan submittal and may include additional plan review fees. REVISIONS REGISTRATION 4Q, 5 SEA= FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE SUM 300 KIRKIAND, WA 98033 PA251272100 FA25.0213.6059 DRAWN BY: DATE: PROJECT NO.: PRINT DATE: DRAWING NAME: BUILDING 'N' M.E.P.PLAN JZ /LH 06/21/07 A03 -446 08/17/07 - 8 :37am A07 -412_BLDG N A31_104.DW SHEET A3.1 Copyright 2007 Freiheit & Ho Architects, Inc., P.S.