Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL07-446 - WESTFIELD SOUTHCENTER MALL - BEBE
BEBE 637 SOUTHCENTER MALL ELO7-446 Parcel No.: .Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Signature: Print Name: doc: EL -4/07 6364200010 637 SOUTHCENTER MALL TUICW BEBE 637 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WIISHIRE BLVD , LOS ANGELES CA Contact Person: Name: ROB HUMPHREY Address: 833 SE MAIN ST #242 , PORTLAND OR Contractor: Name: TRUMP ELECTRIC Address: 39614 N TAMARACK , DEER PARK WA Contractor License No: TRUMPE*969N3 DESCRIPTION OF WORK: ELECTRICAL FOR TENANT IMPROVEMENT REVISION #1 INCLUDES ADDING LOW VOLTAGE TO SCOPE OF WORK Value of Electrical: $8,000.00 Type of Fire Protection: Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and e amined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be compliedi, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pefformance of work. I am authorized to sign and obtain this electrical permit. Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 81e4,u c % 2cc ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 503 320 -5030 Phone: 509 - 276 -9799 Expiration Date: 10/24/2008 Fees Collected: National Electrical Code Edition: EL07 -446 02/22/2008 12/09/2008 Date: �lv% Date: $266.50 2005 7/bscr This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. EL07 -446 Printed: 07 -08 -2008 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: DESCRIPTION OF WORK: ELECTRICAL FOR TENANT IMPROVEMENT Value of Electrical: $8,000.00 Type of Fire Protection: Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 - 3670 Fax: 206 - 431 - 3665 Web site: http.• / /www.ci.tukwila.wa.us 6364200010 637 SOUTHCENTER MALL TUICW BEBE 637 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: ROB HUMPHREY Address: 833 SE MAIN ST #242 , PORTLAND OR Contractor: Name: TRUMP ELECTRIC Address: 39614 N TAMARACK , DEER PARK WA Contractor License No: TRUMPE *969N3 Electrical Service provided by: PUGET SOUND ENERGY Print Name: 1 ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 503 320 -5030 Phone: 509 - 276 -9799 Expiration Date: 10/24/2008 EL07 -446 02/22/2008 08/20/2008 Fees Collected: $266.50 National Electrical Code Edition: 2005 Date: Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo ce of work. I am authorized to sign and obtain this electrical permit. l Signature: // z Date: c L /�- 2/O This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL07 -446 Printed: 02 -22 -2008 Parcel No.: 6364200010 Address: 637 SOUTHCENTER MALL TUICW Suite No: Tenant: BEBE 1: ** *ELECTRICAL * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. PERMIT CONDITIONS Permit Number: EL07 -446 Status: ISSUED Applied Date: 08/27/2007 Issue Date: 02/22/2008 Date: a doc: Cond -Elec EL07 -446 Printed: 02 -22 -2008 E -Mail Address: Company Name: Mailing Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: ti C OuT t_FU41iL Tenant Name: 1 E Property Owners Name: lA S ST Cox -P Mailing Address: I a ooit 1/ 60/ •sr o (J I z) King Co Assessor's Tax No.: l� t t.SN/le L ✓d City Name: (s- Mailing Address: 8 S f klf4ii,) f r Y 2 yI- 3 /b FA-S itsit- Mfrs . co ^. Suite Number: / $ b Floor: 1 New Tenant: Yes . ❑ ..No L.A. CA, State 9 4.0 Zip CONTACT, PERSON - Who do we contact when your permit is ready to be i ssued Day Telephone: , S'b3 =22 0 - 3 701- vg-,u0 Do 9724V City State Zip Fax Number: S'b3 — 2 7 6- 242.3 ELECTRICAL CONTRACTOR INFORMATION City State Zip Contact Person: 7 2-'1 ' 141411-I t Day Telephone: S D) " 3 2 'SO.3 0 E -Mail Address: i Q ) % PfR� iTJ .c•&ax Number: S °3 ' z 9 1, - 14' 3 b Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ � � o Scope of Work (please provide detailed information): Ne Property Served by: )5/ Puget Sound Energy El Seattle City Light Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? Yes ❑ No Type of Use: [ E 7 A t L Type of work: New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm H: Applications\Fomu- Applications On Linea -2007 - Electrical Penult Applia*on.doc bh 1"6.1 At.) r , p) 7W SPA . ❑ Remodel ❑ Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) $140.00 $75.00 ea $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65:00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) BUILDING OWNER OR ELECTRICAL CONTRACTOR: Print Name: Mailing Address: H: Applications\Forms- Applications On L..o4-2007 - ;...e..xrial Permit Applicuion.doc bh p oft 7 City MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Camivals 875.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTE Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. L� Signature: Date: &--/ 7-'7/ 2 F)3 f i< Movoi yZ Day Telephone: S b3 — 3 7b P State Date Application Accepted: Det, Date Application Expires: / . 1 Staff Initials Page 2 of 2 Parcel No.: 6364200010 Permit Number: ELO7 -446 Address: 637 SOUTHCENTER MALL TUB:W Status: APPROVED Suite No: Applied Date: 08/27/2007 Applicant: BEBE Issue Date: Receipt No.: R08 -00518 Initials: WER Payment Date: 02/22/2008 04:12 PM User ID: 1655 Balance: $0.00 Payee: MATTHEW TRUMP TRANSACTION LIST: Type Method Description Amount Payment Check 3047 266.50 ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000.322.101.00.0 213.20 000.345.832.00.0 53.30 Total: $266.50 Payment Amount: $266.50 9064 02/25 9710 TOTAL 266.50 doc: Receipt -06 Printed: 02 -22 -2008 Project: �1 Type of Inspection: Z oo Address: 6rii fl tVV " Date Called: f.--` Special Instructions: Date Wanted: /10 ca:m: Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: • 'Inspector: 'Date: 1'J` -' Dv i / 0N /7 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: COMMENTS: Type of Inspection: . . £ ft'It' CovtK " I Address: 63"1 IM , , ` ��/ Date Called: flit t-5 ra r(Alit-L- L 1 — SuPPoe � i1 a� I Sx - C Pig - Pitta- LASE -L4 reaL Pte( cit_0Q-5 abbe_ or bitiev ;R 1-) - ot:0 14-ce - 'VA e bl.. - _kek. Dc.T Drem-I &41' Sit .1 oFF telak.649 Li[+1 tpt"t 4 Phone No: Project: '`+ Type of Inspection: ji ) /7©0 Address: 63"1 IM , , ` ��/ Date Called: Special Instructions: Date Wanted: X69 �. Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. 'Inspector: n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit 'Date: PERMIT NO. 0-7/oq(os COMMENTS: a kni r 4 a 6 ,<s- e Pt Alt on p2/4 � - ,9L5 2 MA/0 Clgtif- 0. cWI/ c -4i't6 /)4 7 &: _si ,roA r,EJ / / c nh E- e,. IJNs/-/ // J /If Qi/ /441 0 r... 4 N fir 7 4A14 //►iAT7 6 / 5 0GGT 7 44- l9M \ To p.- _ t of A44 /l id/1 / ( T 440 L11 9 41 7o /AA/b MY /fit / flM/T)oA 6 ic44S A Gfr 77 Atk f /n/ G (477 /v Proj t L. Type of Inspection: ) j A d J G /44 LC. Date Called: Special Instructions: Date Wanted: / � a.m Requester: Phone No: tezio 99 INSPECTION RECORD Retain a copy with permit , INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ID Approved per applicable codes. er ections required prior to approval. I --lnspe /? y 58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: COMMENTS: Type of Inspection: 1w/ — Covet5 R.E(1titec -fl on) friv ' - ....Tvisimol4 ? - v'9(o 0.664 t t .I4 t r ►, f 5'Ped -r p (, (A)rruifJ r Z" G/12- or 71Lo J ti0 C -e Requester: 1.41coP4PL -rE Fir( ..of i/ - (1Pro ur tic w ni3-irl 12 " 1e yir _Or — fwitr -rt. pi P Project: &d Type of Inspection: 1w/ Address: 63? friv ' Date Called: Special Instructions: Date Wanted: G/12- a:m m. Requester: Phone No: INSPECTION NO. Approved per applicable codes. INSPECTION RECORD Retain a copy with permit 6 ,01-1111 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ti Corrections required prior to approval. ( Inspector: .101acrthlos 'Date: a l l 2 1 4 4 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Prot Al Type of Inspection: ! � O T , r ,: y5: 2 i Date Called: Special Instructions: ' Wanted: a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Ap} roved per applicable codes. El Corrections required prior to approval. . COMMENTS: Oi.0 - fn tig A ti A/ Insp t 1 46 _ /1 T 4 J24iiQ / I $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project Type of Inspection: Adresli (TC64/1 - FA / G G Date Called: Special Instructions: Date Wanted: 6 /r a.M. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 7- yy6 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 4 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 pproved per applicable codes. El Corrections required prior to approval. COMMENTS: ph . c.L /1-itri G- /%7f,'/7? sr-Akr (lnspe l/ - (/ reiez enlioj Dat � /� /7J El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: MA 1 Type of Inspection: 700_7 Add t} : c S / . �7 �+JT�G� N / / % , Date Called: Special Instructions: Date Wanted: Jj i d/ 3 � i ;- Requester: Phone No: INSPECTION RECORD Retain a copy with permit 1 1°7 y g � PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. OMMENTS: P4- A/11 (U)TiM c,c /G iN A. roved per applicable codes. El Corrections required prior to approval. Inspecto . Date: $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project :p 7 `` Type of Inspection: l . . dress: of , LE✓Lf " Date Called: Special Instructions: Date Wanted: Z a.m. , Requester: Phone No: INSPECTION RECORD Retain a copy with permit �/ 7 9 b INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I?• 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 pproved per applicable codes. COMMENTS: fig oX -- /A/ t G V — A/1f6S/NG / Or o1S / ,C7WE A001/ j C >� - 0/9g C/6-6&//11 - /1ES /�rrA 1 w/11/6 !7 Date:. /_/ / El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. El Corrections required prior to approval. Receipt No.: 'Date: Project: Type of Inspection: o A Date Called: Special Instructions: Date Wanted: Requester: Phone No: INSPECTION RECORD Retain a copy with permit 40 Zi —yytO INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION iK 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 OMMENTS: o/4 wc Inspect roved per applicable codes. El Corrections required p or to approval. /?,/' 1/ 1 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Prod re ee Type of Inspection: 70 I A4dre§: 631 .01/ / Date Called: Special Instructions: -el Date Wanted: Requester: Phone No: INSPECTION RECORD / Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION - g 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 - 3i INSPECTION NO. oved per applicable codes. MMENTS: o1)- 04— RNMAst44 ce,triall/r fat_ CASI/ 1 El Corrections required prior to approval. InsPe 1 47146/il(4/1 I 0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 1 Receipt No.: !Date: Project Info ProjedAddress Bebe - South Center Date 8/17/2007 633 Southcenter Parkway For Building Department Use I Tukwila, WA Applicant Name: David Day, PE Applicant Address: 9990 Richmond Avenue, South Bldg., Suite 300, Bousto Applicant Phone: 713 914 - 0888 2006 Washington State Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms CODE REVIEWED NFPA 70 - NEC OCT 19 2001 Mfg ff Tukwila B ILDIN D ION FILE COPY Revised July 2007 Project Info Project Address Bebe - South Center Date 8/17/2007 633 Southcenter Parkway For Building Department Use Tukwila, NA Applicant Name: David Day, PZ ApplicantAddress: 9990 Richmond Avenue, South Bldg., Suite 300, Houston Applicant Phone: 713- 914 -0888 Project Description ❑ Plans Induded requirements. ❑ New Building ❑ Addition ✓ Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification. Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ,❑ Less man 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) ' . Occupancy Description Allowed Watts per ft Area in ft Allowed x Area Sales Retail 1.50 3138.0 4707.0 Stock Storage'Aaa 0.50 331.0 165.5 Toilet Restroom 0.80 53. 42.4 " From Table 15-1 (over) - document all exceptions on form LTG-LPA Total Allowed Watts 4914.9 Location (floor /room no.) Fixture Description Number of Fixtures , Watts/ Fixture Watts Proposed Sales A/AE - Recessed Fluorescent Downlight 49 52.0 2548.0 Sales 8 - 4' Strip Fluroescent - Display 77 Sales C - 3' Strip Fluroescent 42 25.0 1050.0 Stock T /TE - i'x4' Surface Fluroescent 11 32.0 352.0 Toilet J - 1':4' surface Fluroescent 1 64.0 64.0 Sales xl - Recessed Conbo Flurescent 14 20.0 280.0 Sales R2 - Recessed Combo Fluorescent 26 Sales K3 - Recessed Combo Fluorescent 17 Sales N - Recessed Downlight . 2 Sales P - Linear Fluorescent 1 Sales R - Fitting Room Mirror Fluorescent . 14 22.0 308.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 4602.0 Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Fans Maximum Allowed Lighting Wattage Provosed Lighting Wattage Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track righting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard-wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. list all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Form 1!i Revised July 2007 Use' LPA` (WJsf) Use' LPA /sf) 1.0 Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches) Convention center 1.2 Penitentiary and other Group 1-3 Occupancies 1.0 Courthouse 1.2 Police and fire stations' 1.0 Cafeterias, fast food establishments', restaurants/bars 1.3 Post office 1.1 Dormitory 1.0 Retail' ", retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia ", assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1-1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel/motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference/exhibition half•` 2.0 Workshops 1.4 Laboratory spaces (alt spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility .... 1.3 Main floor building lobbies' (except mall concourses) 12 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces occupancy: 0 Warehouses, storage areas or aircraft storage hangers Q Other Qualification Checklist Lighting 0 Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. Note: If occupancy type is "Other" and fixture Fixtures: answer is checked, the number of fixtures in (Section 1. Fluorescent lbctures which are non - lensed with a) 1 or 2 two lamps, b) reflector the space is not limited by Code. Clearly 1521) or louvers, c) 5-60 watt T-1, T 2, T-4, T -5, T-8 lamps, and d) hard - wired elec- indicate these spaces on plans. If not tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. qualified, do LPA Calculations. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts 3. LED lights. Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Revised duly 2007 TABLE 15 -1 Unit Liclhtinsl Power Allowance (LPA Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be Increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light PowerAllowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w/fl may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three-quarter- height partitions (transparent or opaque). and lighting for free- standing display where the lighting moves with the display are exempt. An additional 1.5 w/ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high Intensity discharge lamps. This additional lighting power is allowed only if the fighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Project Info Proj Addres: B _ South Center Date 8/17/2007 633 Southcenter Parkway For Building Department Use Tukwila, WA Name: David Day, PE Appl. Name 9990 Richmond Avenue, South Bldg., Suite 300, Houst4 Appl. Phone 713 -914 -0888 Project Description ❑plans Included requirements. ❑ New ■Addition ❑Alteration Refer to WSEC Section 1513 for controls and commissioning 'Compliance Option , O Lighting Power Allowance 0-Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy > 60 Iumens/W ❑ Controlled by motion Sensor • Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Tradable Locations Description Allowed Watts per ft or per If Area (ft perimeter (If) or # of items Allowed Watts x ft (or x If) Non - Tradable Locations Description Allowed Watts per ft or per If Area (ft perimeter (If) or # of items Allowed Watts x ft (or x If) Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Exterior Lighting Summary LTG -EXT 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Tradable Maximum Allowed Lighting Wattage Tradable Proposed Lighting Wattage otal Proposed Watts may not exceed Total Allowed Watts for Exterior Non Tradable Maximum Allowed Lighting Wattage Revised July 2007 Total Allowed Watts Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. Total Proposed Watts Non - Tradable Proposed Lighting Wattage roposed Watts may not exceed Allowed Watts for Category Tradable Surfaces (Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded.) Uncovered Parking Areas Parking lots and drives 1 0.15 W/ft Building Grounds Walkways less than 10 feet wide 1.0 W/linear foot Walkways 10 feet wide or greater plaza areas Special feature areas 0.2W/ft Stairways 1.0 W/ft Building Entrances and Exits Main entries 30 W/linear foot of door width Other doors 20 W/linear foot of door width Canopies and Overhangs Canopies (free standing and attached and overhangs) • 1.25 W/11 Outdoor Sales Open areas (including vehicle sales lots) 0.5 W/11 Street frontage for vehicle sales lots. in addition to "open area" allowance 20 W/linear foot Non - Tradable Surfaces (Lighting power density calculations for the following applications can be used only for the specific application and cannot be traded between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise Building Facades 0.2 W/ft for each illuminated wall or surface or 5.0W/linear foot for each illuminated wall or surface Length Automated teller machines and night depositories 270 W per location plus 90 W per additional ATM per location Entrances and gatehouse inspection stations at guarded facilities 1.25 W/ft of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces ") Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W /ft of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces ") permitted in the "Tradable Surfaces" section of this table.) Material handling and associated storage 0.5 W /ft Drive -up windows at fast food restaurants 400W per drive- through Parking near 24 -hour retail entrances 800 W per main entry 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary (back) LTG -EXT TABLE 15 -2 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS Revised July 2007 2006 Washington State Nonresidential Energy Code Compliance Form Lighting Power Allowance Adjustments LTG -LPA 2006 Washington State Nonresidential Energy Code Compliance Forms Adjusted Lighting Power Allowances (Interior) "" From Table 15-1 based on exceptions listed in footnotes Revised July 2007 Project Address ' Bebe _ soutt, center 'Date 8/17/2007 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15-1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft location on LTG - SUM. Location (floor /room no.) Occupancy Description Allowed Watts per ft Ceiling Height for this room Ceiling Height limit for this exception" Adjusted LPA Watts per ft Lighting, Motor, and Transformer 2006 Washington State Nonresidential Energy Code Compliance Forms Permit Plans Checklist LTG -CHK Revised Juy 2007 Project Address Babe - South Center 'Date 8/17/2007 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code I Section (Component (Information Required Location I on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations E1.0 yes 1513.2 Area controls Maximum limit per switch E1.0 n.a. 1513.3 Daylight zone control Schedule with type and features, indicate locations n.a. vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans n.a. 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location n.a. (a) timer w/backup Indicate location n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location n.a. 1513.6.1 (a) occup. sensors Schedule with type and locations n.a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans n.a. 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes I 1514 'Max. watts 'indicate watts for each exit sign 1E1 .o I LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture Attach n.a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) yes 1 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency Imi . 0 I TRANSFORMERS (Section 1540) yes ' 1540 'Transformers 'Indicate size and efficiency 1E3.0 I 2006 Washinllton State Nonresidential Enerav Code Compliance Form If "no" is circled for any question, provide explanation: 2006 Washin on State Nonresidential Ene Code Com • Iiance Form Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Lighting - General Requirements 1513 Lighting Controls: Ughting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling - height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Ughting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shalt be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be Controlled by a single Controlling device provided that they do not include zones facing more than two adjacent cardinal Orientations (i.e. north, east, South, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Ughting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Ughting for all exterior applications shall have automatic controls capable of tuming off exterior lighting when sufficient daylight is available or when the fighting is not required during nighttime hours. Lighting not designated for dusk-to-dawn operation shalt be controlled by either. a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Ughting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft2 enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light factures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of tuming off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches:. Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -oft`' feature, which tums off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power Is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an Over-ride is initiated; and e. controls an area not exceeding 5,000 11 or 5% of the building footprint for footprints over 100,000 ft2, whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off Controls, Occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the 'Guide for Determining Energy Efficiency for Distribution Transformers' published by the National Electrical Manufacturers Association (NEMA TP -1- 2002). 01 -08 -2008 ROB HUMPHREY 833 SE MAIN ST #242 PORTLAND OR 97214 Dear Permit Applicant: Thank you for your cooperation in this matter. Sincerely, PC—)AOU Jd er Marshall Pe t Technician xc: Permit File No. EL07 -446 City of Tukwila RE: Permit Application No. EL07 -446 637 SOUTHCENTER MALL TUKW Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current permit application files, it appears that your permit application applied for on 08/27/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 02/23/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 02/23/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: EL07 -446 DATE: 08 -27 -07 PROJECT NAME: BEBE SITE ADDRESS: ten: SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: „/I BtRfd'fng DWision Public Works Comments: PLAN REVIEW /ROUTING SLIP PERMIT COORD COPY Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete [V Incomplete n Planning Division ❑ Permit Coordinator DUE DATE: 08-30-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU G: Please Route Structural Review Required REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: No further Review Required DATE: DUE DATE: 09-27-07 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 07- 03 -`08 11:42 FROM- pubticworks /dcd 2064313665 City of Tukwila Department of Community Development 6300 Sauthcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431 -3670 Fax: 206-431 -3663 Web site :/ vf�v. '.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. the mail, fax, etc. Date: /1 \ Plan Check/Permit Number: ❑ Response to Incomplete Letter # _ ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued • Revision requested by a City Building Inspector or Plans Examiner Project Name: 15 E. be Project Address: to 3 3 50 'i f e elitr Contact Person: C \applications\Yurnn-applications on line:evince submittal Created: 8.13-2004 Revised: T -680 P002/002 F -457 Steven M. Mullet, Mayor Steve Lancaster, Director Revisions will not be accepted through REC rp-y ,., rCil JUL 0 8 2008 PEFi CENTEil M4/f 5percc #ts3o Phone Number: —C99 g 5 Y— a 8o Summary of Revision: — -f'(Q /0(-' //p Ma 6tre4th k rr ((dew l e Alec e c Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: I% Entered in Permits Plus on License Information License TRUMPE *969N3 Licensee Name TRUMP ELECTRIC Licensee Type ELECTRICAL CONTRACTOR UBI 602395604 Ind. Ins. Account Id OWNER Business Type INDIVIDUAL Address 1 39614 N TAMARACK Address 2 City DEER PARK County SPOKANE State WA Zip 99006 Phone 5092769799 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 10/12/2004 Expiration Date 10/24/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License TRUMPME951BE Business Owner Information Name Role Effective Date Expiration Date TRUMP, M ATHEW E OWNER 08/23/2004 TRUMP, CLARISSA A OWNER 08/23/2004 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Electrical Administrator Information License Name Status TRUMPME951 BE TRUMP, MATHEW E ACTIVE Bond Information 1 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= TRUMPE *969N3 02/22/2008 LIGHT FIXTURE SCHEDULE SYMBOL TYPE MANUF. CATALOG NO. DESCRIPTION LAMP REMARKS 0 A JUNO NACHB - 226Q RECESSED FLOURESCENT DOWNLIGI - IT (2) 26W QUAD VERIFY NAL ACCESSORIES /OPTIONS WITH ER 0 AE JUNO NACH8- 226Q -PLK -E SAME AS "A WITH EMERGENCY BALLAST (2) 26W QUAD VERIFY ADDITIONAL ACCESSORIES /OPTIONS WffH MANUFACTURER LIGHTOLIER SN I 4ORS120SSOC 4' FLOURESCENT STRIP (1) 32W T -8, 4100K MOUNT IN G.C. PROVIDED COVE OR DISPLAY AREA VALENCE. STAGGER AND OVERLAP FIXTURES WHERE SHOWN ON DRAWINGS 1-9--1 B C U GHTOLIER SNI3ORS120SSOC 3' FLUORESCENT STRIP (1) 25W T -8, 4100K MOUNT IN G.C. PROVIDED COVE OR DISPLAY AREA VALENCE. I--0—i 1--+-1 D MERCURY MM1- 24- BIAX -ELP -120 1' -3" FLUORESCENT STRIP (1) 24W 118 MOUNT IN G.C. PROVIDED COVE OR DISPLAY AREA VALENCE. ' F UGHTOLIER 8295WH METAL HALIDE TRACK LIGHTING HEAD ( / M5W 3000K. /FI- I Fl ACT LAMP WITH INTEGRAL OWNER BALLAST H UGHTOUER XT2GVA240120S0 2 X 4 RECESSED FLUORESCENT (2) 32W T -8, 4100K • 1 1 1 HE UGHTOIJER XT2GVA240120SOEM 2 X 4 RECESSED FLUORESCENT FOR EMERGENCY USE (2) 32W T -8, 4100K WITH INTEGRAL BATTERY BACKUP COLUMBIA AWN4- 232 -EB8 -120 SURFACE MOUNTED FLUORESCENT (2) 32W T8 LAMP J ® JE COLUMBIA AWN4- 232 -EB8 -120 -EM SURFACE ERGENCY MOUNTED FLUORESCENT WTTii EM BALLAST (2) 32W T8 LAMP K1 AMERLUX MSRA- 1200 -PAR2OMH - RECESSED 1 LAAM COMBO AREA LIGHT- (1) 20W PAR 20 M.H. K2 AMERLUX MSRA- 2- 20- PAR2OMH- E- WT- 120 -WT RECESSED SALES AREA LIGHT- (2) LAMP COMBO (2) 20W PAR 20 M.H. K3 AMERLUX MSRA- 3- 20- PAR20MH- E -WT -120 -WT RECESSED SALES AREA LIGHT- (3) LAMP COMBO (3) 20W PAR 20 M.H. ME = M VISA CB3700- 1 \1F13 -SLA DECORATNE WALL SCONCE (1) 13W CFT, 2700K MOUNT ON FLUSH OUTLET BOX MOUNTED 6' -10" A.F.F. • N UGHTOUER 1102T28/11265 LOW PROFILE RECESSED COMPACT FLUORESCENT (2) 18W QUAD COMPLETE WITH FRESNEL LENS IN CANOPY OVER DOOR -SEE 4/Al2 P BARTCO BFL 100 /GW LINEAR SHOWCASE FIXTURE (1) 17W T8 LAMP 34" BARTCO FLUORESCENT STRIP UGHT FIXTURE ® = R HERA ES20 /P SUMLITE FLUORESCENT FIXTURE (1) 20W T4 VERIFY ADDITIONAL ACCESSORIES /OPTIONS WITH MANUFACTURER TRK UGHTQUER 6000 WH SERIES UGHTING TRACK, SINGLE CIRCUIT N/A a EM UGHTOUER R4 -12 -18 EMERGENCY UGHT FIXTURE (1) 18W LAMP ADDMONAL OF R ACCESSORIES /OPTIONS WITH ei X UGHTOUER EX1R3SCCN EXIT SIGN EDGE UT ACRYUC LTRS es X1 EMERGI -CITE SNX42 -RC EXIT SIGN EDGE LIT ACRYLIC LTRS 25W. MAX GENERAL NOTES 1. ALL NEW PANELBOARDS, TRANSFORMERS, DISCONNECT SWITCHES, MANUAL MOTOR STARTERS, MAGNETIC STARTERS, LIGHTING CONTACTORS, CIRCUIT BREAKERS IN NEMA ENCLOSURES, ETC. ARE TO BE MANUFACTURED BY SQUARE "0" AND FURNISHED BY BEBE TO THE PROJECT FOR INSTALLATION BY THE ELECTRICAL CONTRACTOR. 2. ALL NECESSARY FUSES ARE THE RESPONSIBILTY OF THE ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL. 3. ALL TRANSFORMERS ARE TO MANUFACTURED IN COMPLIANCE WITH NEMA TP-1 STANDARDS. TYPE "D" FIXTURE (TYPICAL FOR 20) 13,15,17 15 16,18 17 C1 c2-64 03-64 NEW PANEL 1' NEW PANE NEW PANEL "A" CONNECT EMERGENCY FIXTURES IN STOCK ROOM AHEAD OF LOCAL SWITCHING. L N m TYPE "R" FIXTURE (TYPICAL FOR 14) HE 120 VOLT CONTROL — CIRCUIT "C -24" C -1 C -5 C -9 C -12 C -15 C -16 INTERMATIC #T7401 B, 4PST, 120V. C -4 C -6 C-8 C -24 —1-1 L ._ 1 1 C -3 —I-- -I C -7 —I —I C -11 1 i C -14 —I—I I C -17 —1 C-18 L { saFF1T 0 0 NOTES: 1. ALL CONTACTORS SHALL BE 20A. ELECTRICALLY HELD WITH NUMBER OF POLES SHOWN. 2. INSTALL CONTACTORS IN NEMA 1 ENCLOSURE WITH HINGED COVER. 3. PROVIDE WITH MOMENTARY CONTACT SWITCH AS REQUIRED. SWITCHING CONTROL DIAGRAM NOT TO SCALE T.E FAN LIGHTING KEYED NOTES O MOMENTARY CONTACT SWITCHES —SEE SWITCHING CONTROL DIAGRAM THIS SHEET FOR MORE INFO. ELECTRICAL LIGHTING PLAN 1/4' - 1' -0• NOTE: ALL HOMERUNS ON THIS SHEET TO PANEL "C" UNLESS OTHERWISE NOTED. BEBE SPACE #1530 LEVEL 1 STOREFRONT ZONE: TYPE 2 PROJECT KEY PLAN NOT TO SCALE 20 Plan review approval is siatio mom and omissions. Approval of alf1011.104111101111111 does not authorize the violation of any Apt code or minim Receipt of approved told f 4 and '- ♦ BY No changes 9es shall be made to the of work without of Tukwila Building Division. B approval of N D � '�' Revisions will require ivision, . c may include additional pan� � ,,tv submittal L Public Works, Building Division PERMIT NUM ER J.B. FOR SIGN SEPARATE PERMIT REQUIRED FOR: Mechanical • ❑ Electrical Plumbing N Gas Piping City of Tukwila BUILDING DIVISION RUN EXTRA WIRE FOR GROUND SWITCH CONCEALED FROM VIEW FILE / � COPY I , Penult Mo.�LV1[ N& Date d /aa /o$` City of Tukwila BUILDING DIVISION APPROVED PLANS ANO SPECIFICATIONS S!-!AL 1 Er C' :.ANGED, MODIFIED OR ALTERED W(THOUTAUTHORIZATION FROM THE BUILDING 0r710:A.L, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND 1S 7.13JEe",T TO FIELD INSPECTIONS RECEIVED CITY OF TUKWILA AUG 2 7 2007 PERMIT CENTER J/ MEMONINIZE DATE: ,Aug. 11, 2001 JOB NO: 0146.283 DRAWN: ACC CHECKED: KC 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 REVISIONS BID / PERRMIT/ 1.1.. SUBMITTAL 8 /11/200'1 ELECTRICAL 1IH1•NCs PLAN ...mmiu■■•• SHEET NUMBER FILE COPY 15 1 ® 12" A.F.F. W /PULL ST TERMINATE TO BUZZER AT CASH DES 4TA /ELECTRICAL )UTLETS r MANAGER'S DESK TO AT 36" .F.F. J - BOX 2 "X4 "X4" EMPTY BUZZER # TO SECURITY ALARM PANEL TO PUSH BUTTON �-- J -BOX FOR MOTION DE1 TO SECU ALARM P N ON TOI 'A ER Her R C ABOVE OM TO RECEIVER ---- DISCONNECT SWITCH (30/20, NEMA 1) 4-#12-1/2" C. TO CKTS. "A 2,4,6 S TO MAGNETIC DETACHER. DUPLEX HAS WHIP TO ELECTRICAL CHASE AND CONNECTS TO HOUSE POWER. (TYPICAL FOR 2) NEW VAV tX SUSPENDED FROM STRUCTURE FLOOR RECEPTACLE FOR HOUSE POWER. DUPLEX OUTLET TO BE MOUNTED ON FACE OF CASH DESK ADJACENT BUZZER #1 IN ELECTRICAL CHASE TO BUZZER #2 IN STOCK ROOM ROUTE WIRING IN CASH DESK (TYPICAL) RUN EXTRA WIRE FOR GROUND J -BOX FOR MOTION DETECTOR TO SECURITY ALARM PANEL HOLES INSTAL (TYPIC C MNE EL GENERAL POWER PLAN NOTES 1. ALL NEW PANELBOARDS, TRANSFORMERS, DISCONNECT SWITCHES, MANUAL MOTOR STARTERS, MAGNETIC STARTERS, LIGHTING CONTACTORS, CIRCUIT BREAKERS IN NEMA ENCLOSURES, ETC. ARE TO BE MANUFACTURED BY SQUARE "D" AND FURNISHED BY BEBE TO THE PROJECT FOR INSTALLATION BY THE ELECTRICAL CONTRACTOR. 2. ALL NECESSARY FUSES ARE THE RESPONSIBILTY OF THE ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL. 3. ALL TRANSFORMERS ARE TO BE MANUFACTURED IN COMPLIANCE WITH NEMA TP -1 STANDARDS. LANDLORD PROVIDED 200 AMP DISCONNECT SWITCH WITH 200 AMP FUSES NEW 45 KVA TRANSFORMER ON FLOOR NEW PANEL "A' PLENUM RATED SLEEVE THROUGH WALL FOR TELEPHONE WIRING C1 7' -0" A.F.F. SECURITY ALARM PANEL POWER NOTES (KEYED) • ROUTE CONDUITS UP COLUMN TO ABOVE CEIUNG AND TO ELECTRIC PANEL OR TELEPHONE TERMINAL BOARD, AS LABELED. CHANNEL CUT /CORE DRILL FLOOR AND ROUTE CONDUIT TO PULLBOX LOCATED UNDER CASHWRAP. STUB -UP 6" ABOVE FINISHED FLOOR AT CASHWRAP. • G.C. PROVIDED 36"X36" PAINTED BACKBOARD FOR TELEPHONE AND DATA ONLY. QUAD RECEPTACLE SHALL BE LOCATED IN LOWER LEFT OR RIGHT CORNER OF BOARD. LIGHTING CONTACTORS OR TIME CLOCK SHALL NOT BE INSTALLED ON BOARD. RUN 1" EMPTY CONDUIT WITH PULL STRING TO LANDLORD'S TELEPHONE SERVICE CONNECTION POINT IF EXISTING TELEPHONE SERVICE IS NOT AVAILABLE. COORDINATE WITH MALL REPRESENTATIVES AND LOCAL TELEPHONE COMPANY. O4 ELECTRICAL CONTRACTOR TO PROVIDE J -BOX AT 48" A.F.F. AND 1/2" CONDUIT WITH PULLSTRING FOR THERMOSTAT CONTROL WIRING. THERMOSTAT AND CONTROL WIRING PROVIDED BY MECHANICAL CONTRACTOR. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR. ®5 SECURITY KEYPAD, MOUNT 5' -0" A.F.F. COORDINATE LOCATION WITH BEBE ALARM VENDOR. SEE ENTRY ALARM WORK NOTES, THIS SHEET FOR ALL SECURITY ALARM REQUIREMENTS. ®6 SPEAKER AND STEREO SYSTEM. G.C. SHALL COORDINATE INSTALLATION REQUIREMENTS W /BEBE CONSTRUCTION MANAGER. WIRING AND CONDUIT FURNISHED AND INSTALLED BY G.C. RECESSED SPEAKERS TO BE INSTALLED AT SALES AREA CEIUNG IN ACCORDANCE W /MALL REQUIREMENTS BY G.C. (MIN. 20' -0" SET BACK PER MALI REQUIREMENTS) MUSIC SYSTEM SPEAKERS PROVIDED BY BEBE. INSTALL OWNER FURNISHED SPEAKERS AND PRODISC DS CD PLAYER. FURNISH AND INSTALL PLENUM RATE 16 GUAGE STRANDED WIRE. CONFIGURE PRODISC PLAYER FOR 70 VOLT OUTPUT. CONFIGURE SPEAKERS FOR 4 WATT OPERATION AND 70 VOLT INPUT. G.C. IS RESPONSIBLE FOR MAKING ALL CONNECTIONS TO TO THE RECEIVER AND VERIFY THE SOUND SYSTEM IS OPERABLE. SECURITY ALARM WORK A. MOTION DETECTORS, DOOR CONTACTORS, KEY PAD, AND CONTROL PANEL TO BE FURNISHED AND INSTALLED BY "BEBE" VENDOR. B. GENERAL CONTRACTOR SHALL PRE -WIRE ALL ALARM EQUIPMENT C. ALL HOLES FOR DOOR CONTACTORS SHALL BE DRILLED BY GENERAL CONTRACTOR UNDER DIRECT SUPERVISION OF THE "BEBE" ALARM VENDOR WHO SHALL SPECIFY THEIR EXACT LOCATION. D. FINAL CONNECTION TO BE PERFORMED BY "BEBE" VENDOR. E. ALL PRE -WIRE SHALL HAVE INDIVIDUAL HOMERUNS TO CONTROL PANEL USING 6 CONDUCTOR 22 GAGE STRANDED WIRE. F. COORDINATE LOCATION OF MOTION DETECTOR TO AVOID INTERFERANCE WITH LIGHTS AND DIFFUSERS. LEAVE 3' -0" OF WIRE BEELOW CEIUNG FOR FINAL CONNECTION. G. COORDINATE PRE -WIRE TO MOUNT KEYPAD AT 5' -O" A.F.F. H. EACH DEVICE REQUIRES INDMDUAL HOME -RUN TO TELEPHONE TERMINAL BOARD (T.T.B.), DEVICES MAY NOT BE "DAISY CHAINED". STUB -OUT IN DOOR CASING FOR I XARM CONTACT D i D PUSH BUTTON RECEPTACLE FOR DOOR -MAX SENSORMATIC SYSTEM IN TOP OF CANOPY - VERIFY EXACT MOUNTING LOCATION IN FIELD. RUN EXTRA WIRE FOR GROUND — (TYPICAL) 1 IG SENSORMATIC DOOR -MAX EAS CONTROLLER MOUNTED ON TOP OF STORE FRONT CANOPY. FIELD DETERMINE EXACT MOUNTING LOCATION HOLES BY EAS INSTALLER (TYPICAL FOR 2) NOT TO SCALE .CANOPY LOW VOLTAGE WIRING BY EAS INSTALLER UP TO CONTROLLER (TYPICAL FOR 2) ANTENNAS WILL BE PLACED BY INSTALLER IN THE BEST POSMON FOR OPTIMAL SYSTEMS PERFORMANCE (TYPICAL) SENSORMATIC- DIGITAL DOOR -MAX 1,3,5 -18 -21 1 1/4" EMPTY CONDUIT W/ PULL STRING AND TERMINATE ABOVE T.T.B. ELECTRICAL POWER PLAN 1/4' v 1' -O• ELECTRICAL EQUIPMENT SEPCIFICATIONS - ALL EQUIPMENT INDICATED BELOW 15 (FURNISHED BY BEBE AND I5 TO BE INSTALLED BY THE GENERAL CONTRACTOR). EQUIPMENT SHOWN BELOW IS TO BE USED AS A GUIDELINE FOR MINIMUM INSTALLATION. DISCONNECT SWITCH: HEAVY DUTY SINGLE THROW SAFETY SWITCH, 3 POLE, 30 AMP, 480 VOLT, FUSIBLE, WITH 20 AMP FUSES AND NEMA 1 ENCLOSURE. SQUARE D #H361. PANEL A: SQUARE D TYPE NFCU SURFACE MOUNTED COPPER BUS, BOLTED CIRCUIT BREAKER PANELBOARD, 277/480 VOLT, 3 PH., 4 WIRE. TRANSFORMER: 45 KVA, DRY TYPE. SQUARE D #45T3H. PRIMARY: 480 VOLT, 3 PH., 3 WIRE. SECONDARY: 120/208 VOLT, 3 PH., 4 WIRE. PANEL B: SQUARE D TYPE NQODCU SURFACE MOUNTED COPPER BUS, BOLTED CIRCUIT BREAKER PANELBOARD, 120/208 VOLT, 3 PH., 4 WIRE. PANEL C: SQUARE TYPE NQODCU SURFACE MOUNTED COPPER BUS, BOLTED CIRCUIT BREAKER PANELBOARD, 120/208 VOLT, 3 PH., 4 WIRE. CONTACTOR #1 (W /CONTROL RELAY): SEE SWITCHING CONTROL DIAGRAM ON SHEET E1.0. CONTACTOR #2 (W /CONTROL RELAY): SEE SWITCHING CONTROL DIAGRAM ON SHEET E1.0. CONTACTOR #3 (W /CONTROL RELAY): SEE SWITCHING CONTROL DIAGRAM ON SHEET E1.0. - ALL EQUIPMENT INDICATED BELOW 15 (FURNISHED BY THE GENERAL CONTRACTOR AND IS TO BE INSTALLED BY THE GENERAL CONTRACTOR). TIME CLOCK: SEE SWITCHING CONTROL DIAGRAM ON SHEET E1.0. DUPLEX RECEPTACLES: HUBBELL #5262 -WHI. "QUAD" RECEPTACLE: TWO (2) HUBBELL #5262 -WHI DUPLEX RECEPTACLES IN A COMMON JUNCTION BOX WITH A 4 GANG COVER PLATE. ISOLATED GROUND RECEPTACLES: HUBBELL #IG- 5262 --WHI. ISOLATED GROUND "QUAD" RECEPTACLES: TWO (2) HUBBELL #IG- 5262 -WHI DUPLEX RECEPTACLES IN A COMMON JUNCTION BOX WITH A 4 GANG COVER PLATE. GROUND FAULT RECEPTACLE: HUBBELL #GF- 5252 -WA. SINGLE POLE SWITCHES: HUBBELL #HBL- 1221 -WHI. THREE WAY SWITCHES: HUBBELL #HBL - 1223 -WHI. SIGNAL TRANSFORMER: EDWARDS #596. PUSHBUTTON: EDWARDS #1786C -B. BUZZER #1: EDWARDS #660. BUZZER #2: EDWARDS #15 -DM. NOTE: ALL HOMERUNS ON THIS SHEET TO PANEL "B" UNLESS OTHERWISE NOTED. BEBE SPACE #1530 LEVEL 1 © 12" A.F.F. STOREFRONT ZONE: TYPE 2 ® 12" A.F.F. PROJECT KEY PLAN NOT TO SCALE RECEPTACLES MOUNTED IN BULKHEAD ABOVE SHOW WINDOW (TYPICAL FOR 4) RECEPTACLE FOR DOOR --MAX SENSORMATIC SYSTEM ABOVE CEILING - VERIFY EXACT MOUNTING LOCATION IN FIELD. (TYPICAL FOR 3) SENSORMATIC DOOR-MAX EAS CONTROLLER MOUNTED ABOVE CEILING - VERIFY EXACT MOUNTING LOCATION IN FIELD (TYPICAL FOR 3) `11 CITY OF TUKWILp► AUG 2 7 2007 PERMIT CEN l DATE: Aug. 11, 2001 JOB NO: 0146283 DRAWN:1CC CHECKED: KC 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 0 U CL IDC a � 0 REVISIONS SID/ PERMIT/ LL. 5l,ISMITTAL 8/IZn00Z ELECTRICAL POWER PLAN SHEET NUMBER E 15 1 ® 12" A.F.F. W /PULL ST TERMINATE TO BUZZER AT CASH DES 4TA /ELECTRICAL )UTLETS r MANAGER'S DESK TO AT 36" .F.F. J - BOX 2 "X4 "X4" EMPTY BUZZER # TO SECURITY ALARM PANEL TO PUSH BUTTON �-- J -BOX FOR MOTION DE1 TO SECU ALARM P N ON TOI 'A ER Her R C ABOVE OM TO RECEIVER ---- DISCONNECT SWITCH (30/20, NEMA 1) 4-#12-1/2" C. TO CKTS. "A 2,4,6 S TO MAGNETIC DETACHER. DUPLEX HAS WHIP TO ELECTRICAL CHASE AND CONNECTS TO HOUSE POWER. (TYPICAL FOR 2) NEW VAV tX SUSPENDED FROM STRUCTURE FLOOR RECEPTACLE FOR HOUSE POWER. DUPLEX OUTLET TO BE MOUNTED ON FACE OF CASH DESK ADJACENT BUZZER #1 IN ELECTRICAL CHASE TO BUZZER #2 IN STOCK ROOM ROUTE WIRING IN CASH DESK (TYPICAL) RUN EXTRA WIRE FOR GROUND J -BOX FOR MOTION DETECTOR TO SECURITY ALARM PANEL HOLES INSTAL (TYPIC C MNE EL GENERAL POWER PLAN NOTES 1. ALL NEW PANELBOARDS, TRANSFORMERS, DISCONNECT SWITCHES, MANUAL MOTOR STARTERS, MAGNETIC STARTERS, LIGHTING CONTACTORS, CIRCUIT BREAKERS IN NEMA ENCLOSURES, ETC. ARE TO BE MANUFACTURED BY SQUARE "D" AND FURNISHED BY BEBE TO THE PROJECT FOR INSTALLATION BY THE ELECTRICAL CONTRACTOR. 2. ALL NECESSARY FUSES ARE THE RESPONSIBILTY OF THE ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL. 3. ALL TRANSFORMERS ARE TO BE MANUFACTURED IN COMPLIANCE WITH NEMA TP -1 STANDARDS. LANDLORD PROVIDED 200 AMP DISCONNECT SWITCH WITH 200 AMP FUSES NEW 45 KVA TRANSFORMER ON FLOOR NEW PANEL "A' PLENUM RATED SLEEVE THROUGH WALL FOR TELEPHONE WIRING C1 7' -0" A.F.F. SECURITY ALARM PANEL POWER NOTES (KEYED) • ROUTE CONDUITS UP COLUMN TO ABOVE CEIUNG AND TO ELECTRIC PANEL OR TELEPHONE TERMINAL BOARD, AS LABELED. CHANNEL CUT /CORE DRILL FLOOR AND ROUTE CONDUIT TO PULLBOX LOCATED UNDER CASHWRAP. STUB -UP 6" ABOVE FINISHED FLOOR AT CASHWRAP. • G.C. PROVIDED 36"X36" PAINTED BACKBOARD FOR TELEPHONE AND DATA ONLY. QUAD RECEPTACLE SHALL BE LOCATED IN LOWER LEFT OR RIGHT CORNER OF BOARD. LIGHTING CONTACTORS OR TIME CLOCK SHALL NOT BE INSTALLED ON BOARD. RUN 1" EMPTY CONDUIT WITH PULL STRING TO LANDLORD'S TELEPHONE SERVICE CONNECTION POINT IF EXISTING TELEPHONE SERVICE IS NOT AVAILABLE. COORDINATE WITH MALL REPRESENTATIVES AND LOCAL TELEPHONE COMPANY. O4 ELECTRICAL CONTRACTOR TO PROVIDE J -BOX AT 48" A.F.F. AND 1/2" CONDUIT WITH PULLSTRING FOR THERMOSTAT CONTROL WIRING. THERMOSTAT AND CONTROL WIRING PROVIDED BY MECHANICAL CONTRACTOR. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR. ®5 SECURITY KEYPAD, MOUNT 5' -0" A.F.F. COORDINATE LOCATION WITH BEBE ALARM VENDOR. SEE ENTRY ALARM WORK NOTES, THIS SHEET FOR ALL SECURITY ALARM REQUIREMENTS. ®6 SPEAKER AND STEREO SYSTEM. G.C. SHALL COORDINATE INSTALLATION REQUIREMENTS W /BEBE CONSTRUCTION MANAGER. WIRING AND CONDUIT FURNISHED AND INSTALLED BY G.C. RECESSED SPEAKERS TO BE INSTALLED AT SALES AREA CEIUNG IN ACCORDANCE W /MALL REQUIREMENTS BY G.C. (MIN. 20' -0" SET BACK PER MALI REQUIREMENTS) MUSIC SYSTEM SPEAKERS PROVIDED BY BEBE. INSTALL OWNER FURNISHED SPEAKERS AND PRODISC DS CD PLAYER. FURNISH AND INSTALL PLENUM RATE 16 GUAGE STRANDED WIRE. CONFIGURE PRODISC PLAYER FOR 70 VOLT OUTPUT. CONFIGURE SPEAKERS FOR 4 WATT OPERATION AND 70 VOLT INPUT. G.C. IS RESPONSIBLE FOR MAKING ALL CONNECTIONS TO TO THE RECEIVER AND VERIFY THE SOUND SYSTEM IS OPERABLE. SECURITY ALARM WORK A. MOTION DETECTORS, DOOR CONTACTORS, KEY PAD, AND CONTROL PANEL TO BE FURNISHED AND INSTALLED BY "BEBE" VENDOR. B. GENERAL CONTRACTOR SHALL PRE -WIRE ALL ALARM EQUIPMENT C. ALL HOLES FOR DOOR CONTACTORS SHALL BE DRILLED BY GENERAL CONTRACTOR UNDER DIRECT SUPERVISION OF THE "BEBE" ALARM VENDOR WHO SHALL SPECIFY THEIR EXACT LOCATION. D. FINAL CONNECTION TO BE PERFORMED BY "BEBE" VENDOR. E. ALL PRE -WIRE SHALL HAVE INDIVIDUAL HOMERUNS TO CONTROL PANEL USING 6 CONDUCTOR 22 GAGE STRANDED WIRE. F. COORDINATE LOCATION OF MOTION DETECTOR TO AVOID INTERFERANCE WITH LIGHTS AND DIFFUSERS. LEAVE 3' -0" OF WIRE BEELOW CEIUNG FOR FINAL CONNECTION. G. COORDINATE PRE -WIRE TO MOUNT KEYPAD AT 5' -O" A.F.F. H. EACH DEVICE REQUIRES INDMDUAL HOME -RUN TO TELEPHONE TERMINAL BOARD (T.T.B.), DEVICES MAY NOT BE "DAISY CHAINED". STUB -OUT IN DOOR CASING FOR I XARM CONTACT D i D PUSH BUTTON RECEPTACLE FOR DOOR -MAX SENSORMATIC SYSTEM IN TOP OF CANOPY - VERIFY EXACT MOUNTING LOCATION IN FIELD. RUN EXTRA WIRE FOR GROUND — (TYPICAL) 1 IG SENSORMATIC DOOR -MAX EAS CONTROLLER MOUNTED ON TOP OF STORE FRONT CANOPY. FIELD DETERMINE EXACT MOUNTING LOCATION HOLES BY EAS INSTALLER (TYPICAL FOR 2) NOT TO SCALE .CANOPY LOW VOLTAGE WIRING BY EAS INSTALLER UP TO CONTROLLER (TYPICAL FOR 2) ANTENNAS WILL BE PLACED BY INSTALLER IN THE BEST POSMON FOR OPTIMAL SYSTEMS PERFORMANCE (TYPICAL) SENSORMATIC- DIGITAL DOOR -MAX 1,3,5 -18 -21 1 1/4" EMPTY CONDUIT W/ PULL STRING AND TERMINATE ABOVE T.T.B. ELECTRICAL POWER PLAN 1/4' v 1' -O• ELECTRICAL EQUIPMENT SEPCIFICATIONS - ALL EQUIPMENT INDICATED BELOW 15 (FURNISHED BY BEBE AND I5 TO BE INSTALLED BY THE GENERAL CONTRACTOR). EQUIPMENT SHOWN BELOW IS TO BE USED AS A GUIDELINE FOR MINIMUM INSTALLATION. DISCONNECT SWITCH: HEAVY DUTY SINGLE THROW SAFETY SWITCH, 3 POLE, 30 AMP, 480 VOLT, FUSIBLE, WITH 20 AMP FUSES AND NEMA 1 ENCLOSURE. SQUARE D #H361. PANEL A: SQUARE D TYPE NFCU SURFACE MOUNTED COPPER BUS, BOLTED CIRCUIT BREAKER PANELBOARD, 277/480 VOLT, 3 PH., 4 WIRE. TRANSFORMER: 45 KVA, DRY TYPE. SQUARE D #45T3H. PRIMARY: 480 VOLT, 3 PH., 3 WIRE. SECONDARY: 120/208 VOLT, 3 PH., 4 WIRE. PANEL B: SQUARE D TYPE NQODCU SURFACE MOUNTED COPPER BUS, BOLTED CIRCUIT BREAKER PANELBOARD, 120/208 VOLT, 3 PH., 4 WIRE. PANEL C: SQUARE TYPE NQODCU SURFACE MOUNTED COPPER BUS, BOLTED CIRCUIT BREAKER PANELBOARD, 120/208 VOLT, 3 PH., 4 WIRE. CONTACTOR #1 (W /CONTROL RELAY): SEE SWITCHING CONTROL DIAGRAM ON SHEET E1.0. CONTACTOR #2 (W /CONTROL RELAY): SEE SWITCHING CONTROL DIAGRAM ON SHEET E1.0. CONTACTOR #3 (W /CONTROL RELAY): SEE SWITCHING CONTROL DIAGRAM ON SHEET E1.0. - ALL EQUIPMENT INDICATED BELOW 15 (FURNISHED BY THE GENERAL CONTRACTOR AND IS TO BE INSTALLED BY THE GENERAL CONTRACTOR). TIME CLOCK: SEE SWITCHING CONTROL DIAGRAM ON SHEET E1.0. DUPLEX RECEPTACLES: HUBBELL #5262 -WHI. "QUAD" RECEPTACLE: TWO (2) HUBBELL #5262 -WHI DUPLEX RECEPTACLES IN A COMMON JUNCTION BOX WITH A 4 GANG COVER PLATE. ISOLATED GROUND RECEPTACLES: HUBBELL #IG- 5262 --WHI. ISOLATED GROUND "QUAD" RECEPTACLES: TWO (2) HUBBELL #IG- 5262 -WHI DUPLEX RECEPTACLES IN A COMMON JUNCTION BOX WITH A 4 GANG COVER PLATE. GROUND FAULT RECEPTACLE: HUBBELL #GF- 5252 -WA. SINGLE POLE SWITCHES: HUBBELL #HBL- 1221 -WHI. THREE WAY SWITCHES: HUBBELL #HBL - 1223 -WHI. SIGNAL TRANSFORMER: EDWARDS #596. PUSHBUTTON: EDWARDS #1786C -B. BUZZER #1: EDWARDS #660. BUZZER #2: EDWARDS #15 -DM. NOTE: ALL HOMERUNS ON THIS SHEET TO PANEL "B" UNLESS OTHERWISE NOTED. BEBE SPACE #1530 LEVEL 1 © 12" A.F.F. STOREFRONT ZONE: TYPE 2 ® 12" A.F.F. PROJECT KEY PLAN NOT TO SCALE RECEPTACLES MOUNTED IN BULKHEAD ABOVE SHOW WINDOW (TYPICAL FOR 4) RECEPTACLE FOR DOOR --MAX SENSORMATIC SYSTEM ABOVE CEILING - VERIFY EXACT MOUNTING LOCATION IN FIELD. (TYPICAL FOR 3) SENSORMATIC DOOR-MAX EAS CONTROLLER MOUNTED ABOVE CEILING - VERIFY EXACT MOUNTING LOCATION IN FIELD (TYPICAL FOR 3) `11 CITY OF TUKWILp► AUG 2 7 2007 PERMIT CEN l DATE: Aug. 11, 2001 JOB NO: 0146283 DRAWN:1CC CHECKED: KC 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 0 U CL IDC a � 0 REVISIONS SID/ PERMIT/ LL. 5l,ISMITTAL 8/IZn00Z ELECTRICAL POWER PLAN SHEET NUMBER PANEL NEW "C" LUGS MAIN 225 AMP 120/208 VOLT 3 PHASE 4 WIRE BREAKER M -L -O 11,162 125% 1ST 10KW © 100% REMAINING 0 50% USE CKT. NO. LOAD BKR SIZE A B C BKR SIZE LOAD CKT. NO. USE SALES AREA LIGHTING 1 780 20/ 1,650 it It di NN 0 AO OW Ok 111 IIII1101 i..s 1 0 1, 1,650 .1 di N si 20/1 8735 2 SPARE it 111 .111111 1111 illi ..Ilk 01 IIII ..IR i..� A oil Ai III 3 5096 3 780 9257 4 384 4 ENTRY LIGHTS ROTUNDA LIGHTS 5 240.0 5096 390 6 6 7 240 7 2 /1 20 /1 540 8 SHOW WDW REC SALES AREA LIGHTING 9 920 ..Ok .. 01 •.111 DVR REC 540 10 001 11 820 SECURITY SYSTEM ik SI 111 663 12 DISPLAY LIGHTS EXIT /EMERG. /NITE LTS 13 778 360 12 TELEPHONE 631 14 13 FITTING ROOM LTS 15 300 14 1103 16 SOFFIT LIGHTS 15 i 17 300 500 16 1117 18 i STOCK ROOM LTS 19 516 17 18 JB FOR CASHWRAP 1200 20 SIGN if SPARE 21 500 19 SPARE CASH WRAP REC 22 SPARE 111111 IA BLANK -1111 r 23 500 21 23 500 24 TIME CLOCK /CONTACTORS 0 irr� ^ •001 1650 24 25 23 25 4685 24 26 SPARE 26 SPARE MN 25 27 4527 26 28 8 27 29 4530 V V 2 30 f 1 29 " *" INDICATES PANEL LOCKS PHASE k 4685 WATTS PHASE B: 4527 WATTS PHASE C: 4530 WATTS 30 BALANCE 3.37 % CONNECTED 13,742 W. 38.17 A. DEMAND 18,759 W. 52.1 A. TOTAL: 13742 WATTS PANEL NEW "A" LUGS MAIN 250 AMP 277/480 VOLT 3 PHASE 4 WIRE BREAKER 200 AMP 11,162 125% 1ST 10KW © 100% REMAINING 0 50% USE CKT. NO. LOAD BKR SIZE A B C BKR SIZE LOAD CKT. NO. USE CASH REGISTERS 1 5096 2O/ 1,650 it It di NN 0 AO OW Ok 111 IIII1101 i..s 1 0 1, 1,650 II 2 I III A It 60/3 8735 2 2 NEW VAV BOX 3 5096 3 750 9257 4 TRANSFORMER FEED 4 -12(a) INSTALLED CASH WRAP REC 5 5 5096 I 9020 6 SPARE 7 7 2 /1 20 /1 8 SPARE �rIR S 01 ON 01 A MINA IIII 111 8 =� ..Ok .. 01 •.111 DVR REC 9 360 180 10 SECURITY SYSTEM ik SI 111 COMPUTER CART IG 9 180 360 12 TELEPHONE MNGRS DESK REC 13 13 14 14 MICRO /REFRIG 15 1500 15 500 16 SENSORMATIC 16 17 I 17 18 JB FOR CASHWRAP ' 19 18 if /3 , BLANK 19 SPARE CASH WRAP REC 21 720 20 BLANK -1111 r 22 21 23 7 / 22 1650 24 WATER HEATER 23 25 4685 24 26 SPARE MN 25 27 4527 26 8 27 29 4530 V 28 2 1 29 "* INDICATES PANEL LOCKS PHASE A: 5735 WATTS PHASE B: 9257 WATTS PHASE C: 9020 WATTS 30 I CONNECTED 27,012 W. 75.03 A. DEMAND 32,779 W. 91.0 A. TOTAL: 27012 WATTS •* NDICATES PANEL LOCKS PHASE A: 13831 WATTS PHASE B: 14353 WATTS PHASE C: 14116 WATTS BALANCE: 3.64 % CONNECTED 42,300 W. 50.90 A. DEMAND 48,067 W. 57.8 A. TOTAL: 42300 WATTS PANEL NEW "B" LUGS MAIN 225 AMP 120/208 VOLT 3 PHASE 4 WIRE BREAKER 125 AMP 11,162 125% 1ST 10KW © 100% REMAINING 0 50% USE CKT. NO. LOAD BKR SIZE A B C BKR SIZE LOAD CKT. NO. USE CASH REGISTERS 1 1500 20/ 1,650 it It di NN 0 AO OW Ok 111 IIII1101 i..s 1 0 1, 1,650 MISCELLANEOUS it d 20/1 1080 2 SALES AREA REC 11111 1 3 750 3,226 TOTAL WATTAGE TOTAL AMPERAGE NOTES: * USE GREATER LOAD OF THE TWO ** SHOW WINDOW LIGHTING CALCULATED PER NEC ARTICLE 220 200 VA PER LF OF SHOW WINDOW MINUS ACTUAL LIGHTING REQUIRED ELECTRICAL SERVICE 720 4 -12(a) INSTALLED CASH WRAP REC 5 720 1080 6 MNGRS DESK COMP 7 750 180 8 STOCK ROOM REC ..Ok .. 01 •.111 DVR REC 9 360 180 10 SECURITY SYSTEM ik SI 111 COMPUTER CART IG 11 180 360 12 TELEPHONE MNGRS DESK REC 13 540 14 SPARE MICRO /REFRIG 15 1500 500 16 SENSORMATIC SPARE 17 500 18 JB FOR CASHWRAP 19 /3 , 20 SPARE CASH WRAP REC 21 720 22 SPARE 23 7 / 1650 24 WATER HEATER 25 4685 26 SPARE MN PANEL "C" FEED 27 4527 8 29 4530 V 2 "* INDICATES PANEL LOCKS PHASE A: 5735 WATTS PHASE B: 9257 WATTS PHASE C: 9020 WATTS BALANCE: 5.64 CONNECTED 27,012 W. 75.03 A. DEMAND 32,779 W. 91.0 A. TOTAL: 27012 WATTS ELECTRICAL SERVICE LOAD SUMMARY LOAD DESCRIPTION ACTUAL CONNECTED LOAD N.E.C. DEMAND FACTOR N.E.C. DEMAND WATTAGE LIGHTING 11,162 125% 1ST 10KW © 100% REMAINING 0 50% 13,952 RECEPTACLES 7,200 7,200 AIR CONDITIONING* HEATING* 18.39 AMPS 480 x 1.732 0% FULL HEATING LOAD 15,289 WATER HEATER 1,650 100% 1,650 MISCELLANEOUS 3,000 100% 3,000 CASH REGISTERS 3,000 125% 3,750 SHOW WINDOW ** LIGHTING REQUIREMENT 20' 3,226 TOTAL WATTAGE TOTAL AMPERAGE NOTES: * USE GREATER LOAD OF THE TWO ** SHOW WINDOW LIGHTING CALCULATED PER NEC ARTICLE 220 200 VA PER LF OF SHOW WINDOW MINUS ACTUAL LIGHTING REQUIRED ELECTRICAL SERVICE 48,067 57.8 -12(a) INSTALLED NEW 200A. GENERAL NOTES 1. ALL NEW PANELBOARDS, TRANSFORMERS, DISCONNECT SWITCHES, MANUAL MOTOR STARTERS, MAGNETIC STARTERS, LIGHTING CONTACTORS, CIRCUIT BREAKERS IN NEMA ENCLOSURES, ETC. ARE TO BE MANUFACTURED BY SQUARE "D" AND FURNISHED BY BEBE TO THE PROJECT FOR INSTALLATION BY THE ELECTRICAL CONTRACTOR. 2. ALL NECESSARY FUSES ARE THE RESPONSIBILTY OF THE ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL. 3. ALL TRANSFORMERS ARE TO BE MANUFACTURED IN COMPLIANCE WITH NEMA TP -1 STANDARDS. ELECTRICAL SPECIFICATIONS THE TOTAL INSTALLATION SHALL COMPLY WITH THE LANDLORD'S REQUIREMENTS. THIS IS A NEW SPACE. REMOVE ANY EXISTING UGHTING FIXTURES, SWITCHES, JUNCTION BOXES, CONDUIT, WIRING, ETC., CURRENTLY IN THE SPACE AND NOT REQUIRED FOR THE NEW INSTALLATION. CONTACT LANDLORD TO DETERMINE THE SCOPE OF PROVIDING NEW SERVICE TO THE SPACE, AS REQUIRED. NEW SERVICE, AS REQUIRED, SHALL BE A PART OF THE ELECTRICAL CONTRACT. COORDINATE ALL REQUIRED WORK AT DISTRIBUTION CENTER WITH LANDLORD TO ENSURE COMPATIBILITY /ACCEPTABILITY /AVAILABILITY OF SERVICE AS REQUIRED AND INDICATED. IF ANY ISSUES ARISE WITH REGARD TO SERVICE SIZE AND AVAILABILITY OF CERTAIN SIZED DISTRIBUTION EQUIPMENT, CONTACT ARCHITECT AND /OR ENGINEER PRIOR TO BID FOR DISPOSITION. BASE BID SHALL INCLUDE ALL REQUIRED WORK AT LANDLORD'S DISTRIBUTION CENTER AND SHALL BE COMPLETE IN EVERY ASPECT AS REQUIRED TO ACCOMODATE NEW SERVICE. NO EXTRAS WILL BE ALLOWED FOR WORK NOT INCLUDED IN BASE BID. THE LANDLORD WILL PROVIDE SERVICE WIRING AND CONDUIT TO A 200 AMP (MIN.) FUSED DISCONNECT SWITCH ON BACK WALL OF TENANT SPACE. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL NEW SERVICE CONDUIT AND WIRING AND CONNECT TO LANDLORD PROVIDED EMPTY CONDUIT AND EXTEND TO NEW EQUIPMENT LOCATION AS REQUIRED. VERIFY LOCATION OF LANDLORD'S ELECTRICAL WIREWAY AND LENGTH OF SERVICE WIRING REQUIRED. INSTALL ALL NEW OWNER PROVIDED ELECTRICAL EQUIPMENT AS SHOWN AND CALLED FOR. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL NEW TYPEWRITTEN PANEL DIRECTORIES AS SHOWN AND REQUIRED. CIRCUITS SHALL BE CONNECTED TO THE PANELS AND ARRANGED TO COMPLY WITH THE NUMBERS SHOWN ON THE DRAWINGS AS REQUIRED. ANY WORK PERFORMED ASIDE FROM THAT SHOWN, INDICATED OR IMPLIED MUST BE APPROVED BY THE PROJECT MANAGER AND /OR ENGINEER BEFORE STARTING. UNUSED CIRCUITS SHALL BE UTILIZED AS SPARES. INSTALL NEW LANDLORD PROVIDED METER AS SHOWN AND REQUIRED. FOR ANY CHANGE IN METERING /SUB - METERING OR FOR SPECIFIC METERING REQUIREMENTS, THE ELECTRICAL CONTRACTOR SHALL CONTACT THE LANDLORD /UTILITY COMPANY. NEW OWNER PROVIDED CONTACTORS SHALL BE INSTALLED IN THE LOCATION AS SHOWN AND CALLED FOR. NEW TIME CLOCK SHALL BE FURNISHED AND INSTALLED AS SHOWN AND CALLED FOR. LANDLORD TO PROVIDE LIMITED /TEMPORARY POWER AT LOCATIONS THRU THE MALL CONCOURSE. THE MECHANICAL CONTRACTOR SHALL INSTALL THE NEW VAV BOX AS SHOWN AND CALLED FOR. FURNISH AND INSTALL NEW CONDUIT AND POWER WIRING /CONTROL WIRING AS REQUIRED AND CONNECT TO THE NEW ELECTRICAL EQUIPMENT AS SHOWN. PROVIDE TELEPHONE SERVICE FROM DISTRIBUTION BACKBOARD REMOTE FROM THE SPACE AND A 1" EMPTY CONDUIT WITH PULL STRING FROM THE DISTRIBUTION BACKBOARD TO THE SPACE. BEBE VENDOR SHALL FURNISH AND INSTALL ALL ADDITIONAL CONDUIT REQUIRED IN THE SPACE. A PLENUM RATED SLEEVE I5 REQUIRED AT BACK WALL FOR TELEPHONE WIRING. CONTACT TELEPHONE COMPANY TO ARRANGE FOR TELEPHONE SERVICE. BEBE VENDOR SHALL FURNISH AND INSTALL ALL ADDITIONAL CONDUIT REQUIRED. A NEW TELEPHONE TERMINAL BOARD SHALL BE FURNISHED AND INSTALLED AS SHOWN. TELEPHONE TERMINAL BOARD SHALL BE 36" X 36" PLYWOOD, 3/4" THICK, MOUNTED ON WALL, READY TO RECEIVE TELEPHONE EQUIPMENT. UGHTING CONTACTORS, TIME CLOCKS OR OTHER MISCELLANEOUS ELECTRICAL COMPONENTS SHALL NOT BE INSTALLED ON THE BOARD. ALL REQUIRED CLEARANCES SHALL BE MAINTAINED AT ALL ELECTRICAL EQUIPMENT, INCLUDING, BUT NOT LIMITED TO TRANSFORMER, ELECTRICAL PANELS, ETC. AND COMPLY WITH N.E.C. ARTICLE 110. CONTACT THE LANDLORD TO DETERMINE EXACT REQUIREMENTS FOR A NEW FIRE ALARM SYSTEM. IF REQUIRED THE CONTRACTOR SHALL FURNISH AND INSTALL A NEW FIRE ALARM SYSTEM IN THE SPACE, INCLUDING SMOKE DETECTORS, HORN /STROBES, PULL STATIONS, FIRE ALARM CONTROL PANEL (OR CONNECTION TO MALL CENTRAL SYSTEM), CONDUIT, WIRING, ETC. THE LANDLORD AND /OR THE LOCAL FIRE MARSHALL'S OFFICE SHALL BE CONTACTED TO DETERMINE THE SCOPE OF PROVIDING NEW FIRE ALARM SYSTEM, TYPE AND NUMBER OF DEVICES, NUMBER OF CONTROL WIRES REQUIRED, PROGRAMMING OF NEW COMPONENTS /DEVICES, ETC., IN THE SPACE. INSTALLATION OF NEW FIRE ALARM SYSTEM SHALL COMPLY WITH NFPA 72A AND LOCAL CODES AS REQUIRED. FIRE ALARM SYSTEM SHALL BE PART OF THE BASE BID. TEMPERATURE CONTROL WORK WILL BE A PART OF THE MECHANICAL CONTRACT. REFER TO ARCHITECTURAL DRAWINGS FOR LIGHT FIXTURE SCHEDULE, EXACT LOCATION OF CEILING GRID, LIGHT FIXTURES, HEIGHT OF EQUIPMENT, ETC. ELECTRICAL GENERAL NOTES THE TOTAL INSTALLATION SHALL COMPLY WITH THE LANDLORD'S REQUIREMENTS. EVERY ASPECT OF ELECTRICAL WORK SHALL BE COMPLETE. THE CONTRACT SHALL INCLUDE EACH ITEM OF MATERIAL AND LABOR NECESSARY TO COMPLETE THE WORK DESCRIBED, SHOWN, OR IMPLIED ON DRAWINGS OR SPECIFICATIONS. WHEN ADJUSTMENTS ARE REQUESTED BY THE TENANT, CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO THE WORK WHEN SUCH ADJUSTMENTS ARE NECESSARY FOR PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. THE ELECTRICAL CONTRACTOR SHALL FIELD VERIFY AND VIEW ALL EXISTING CONDITIONS BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS DESCRIBED AND SHOWN. EXTRAS WILL NOT BE PERMITTED FOR FAILURE TO MAKE THIS VISIT. ANY ITEM DAMAGED BY ELECTRICAL CONTRACTOR I5 TO BE REPAIRED IMMEDIATELY AND AT NO COST TO THE OWNER. CONTRACTOR SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER OF ERRORS, OMISSIONS OR DISCREPANCIES BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, OR, FAJUNG SUCH NOTICE, SHALL BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER. CONTRACTOR SHALL PROVIDE ALL FIXTURES, DEVICES, ACCESSORIES, OFFSETS, AND MATERIALS NECESSARY TO FACILITATE THE SYSTEM'S FUNCTIONING AS INDICATED BY THE DESIGN AND THE EQUIPMENT FURNISHED BY OTHERS. WARRANTEE FOR ALL EQUIPMENT AND ONE YEAR GUARANTEE OF ALL WORKMANSHIP, COMMENCING ON DATE OF ACCEPTANCE BY THE TENANT. WORK SHALL INCLUDE START UP OF ALL SYSTEMS, WARRANTIES FOR EQUIPMENT, ONE E ALL Q MENT E YEAR GUARANTEE OF ALL WORKMANSHIP, FULL ONE (1) YEAR MAINTENANCE, PARTS AND SERVICE CONTRACT FOR ALL EQUIPMENT FURNISHED UNDER THE CONTRACT. FURNISH ALL MANUALS, MAINTENANCE INSTRUCTIONS, AND WARRANTIES TO TENANT. ALL WIRE SHALL BE COPPER. MINIMUM SIZE #12 AWG. ALL CONDUCTORS #10 AND SMALLER SHALL HAVE TYPE "THHN" INSULATION. CONDUCTORS LARGER THAN #10 SHALL HAVE TYPE "THW' INSULATION. ALL WIRE SHALL BE IN CONDUIT. FLEXIBLE CONDUIT MAY BE USED FOR FIXTURE AND EQUIPMENT CONNECTIONS ONLY AND SHALL NOT EXCEED 3 FEET. CONDUIT EXPOSED TO THE WEATHER SHALL BE RIGID. ALL OTHER CONDUIT SHALL BE EMT. CONDUIT IN FINISHED AREAS SHALL BE CONCEALED. CONDUIT IN UNFINISHED AREAS MAY BE EXPOSED. HOME RUNS OVER 100' IN LENGTH SHALL BE #10 WIRE. CONTRACTOR SHALL ENSURE THAT ENTIRE INSTALLATION COMPUES WITH N.E.C. ARTICLE 110 -26. ADJUSTMENTS TO ACCOMMODATE CLEARANCE REQUIREMENTS SHALL BE DISCUSSED WITH ARCHITECT AND /OR ENGINEER. ALL PENETRATIONS THROUGH WALLS, CEIUNGS, FLOORS, ETC. SHALL BE SEALED SO THAT THEY ARE AIR, WATER AND FIRE TIGHT. ALL ELECTRICAL SERVICE EQUIPMENT INCLUDING DISCONNECT SWITCHES, PANELS, PUSHBUTTONS AND STARTERS SHALL BE PROVIDED WITH ENGRAVED BAKELITE NAMEPLATES. SWITCHABLE UGHTING CIRCUITS AT THE PANEL SHALL BE FITTED WITH TYPE "SWD" BREAKERS. ELECTRICAL CONTRACTOR SHALL CONNECT SIGN WHICH WILL BE FURNISHED BY SIGN CONTRACTOR. LIGHTING FIXTURES WILL BE FURNISHED BY THE TENANT AND SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR ACCORDING TO U.B.0 STANDARD. THE ELECTRICAL CONTRACTOR SHALL REVIEW MATERIALS AT THE TIME OF DEUVERY AND IMMEDIATELY REPORT ANY DAMAGE OR MISSING PIECES. CASH REGISTERS WILL BE FURNISHED BY THE TENANT AND SET IN PLACE BY THE ELECTRICAL CONTRACTOR. ELECTRICAL CONTRACTOR SHALL INSTALL EMPTY CONDUITS BELOW THE FLOOR BETWEEN THE CASH DESKS AS SHOWN. SWITCHES SHALL BE MOUNTED 4' -O" ABOVE FLOOR UNLESS NOTED OTHERWISE. CONFIRM EXACT LOCATION OF OUTLETS AND DEVICES WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. FURNISH AND INSTALL OUTLET BOXES, DEVICES, COVER PLATES AND FLANGES AS REQUIRED. IG AND GFI.RECEPTACLES SHALL BE RATED AT 20 AMPERES AND SHALL HAVE A DEDICATED INSULATED GREEN GROUND WIRE. RUN THE GROUND WIRE TO BE CONTINUOUS AND UNSPLICED BETWEEN THE DEVICE AND THE PANEL GROUND BUS. ALL FIXTURES SHALL BE SUPPORTED ACROSS CEILING TEES OR FROM STRUCTURE ABOVE. CEILING TILES OR PLASTER CEILING SHALL NOT SUPPORT ANY FIXTURES. EXACT LOCATION OF CEILING GRID, LIGHT FIXTURES, ETC. AND SYMBOLS UST, FIXTURE SCHEDULE, NOTES AND OTHER SPECIFICATION REQUIREMENTS ARE SHOWN ON ARCHITECTURAL DRAWINGS . FURNISH AND INSTALL SWITCHES IN SALES AREA FOR LOCAL LIGHTING CONTROL IN COMPLIANCE WITH LOCAL ENERGY STANDARDS FOR BI - LEVEL SWITCHING. SWITCHES SHALL BE MOUNTED AS SHOWN ON THE DRAWING. TO IDENTIFY CIRCUITS BEING SWITCHED, FURNISH AND INSTALL LABELS ON SWITCHES. PERMANENTLY AFFIX LABELS TO COVER PLATES. FURNISH AND INSTALL TIMECLOCK AND CONTACTORS TO SERVE ALL LIGHTING CIRCUITS FOR AUTOMATIC SHUTDOWN OF LIGHTING AS REQUIRED. MOUNT TIMECLOCK AND CONTACTORS ADJACENT TO UGHTING PANEL AS SHOWN AND CALLED FOR. ALL MATERIAL AND EQUIPMENT SHALL NI L E NTSALLBEFUR SHED AS SPECIFIED, EXCEPT Q S E E C WHERE SUBSTITUTION IS APPROVED BY THE TENANT. PROPOSAL SHALL BE BASED ON SPECIFIED TERIAL AND EQUIPMENT. BIDDERS ARE MA AN UIPMEN BIDDER Q ENCOURAGED TO SUBMIT ALTERNATE PROPOSALS ON ANY ALTERNATE MATERIALS AND /OR EQUIPMENT THEY WISH TO PROPOSE, INCLUDING ANY PRICE CHANGES EFFECTED BY ACCEPTANCE OF ALTERNATES. ALTERNATE PROPOSALS SHALL INCLUDE COST OF ANY CHANGES REQUIRED BY OTHER TRADES DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT. ALTERNATE PROPOSALS WILL BE ACCEPTED OR REJECTED BEFORE ISSUANCE OF CONTRACTS. CHANGES WILL NOT BE ALLOWED AFTER THE CONTRACT IS SIGNED. FIREPROOF ALL PENLIRATIONS THROUGH FIRE RATED ASSEMBLIES TO THE SAME OR GREATER RATING THAN THAT OF THE ASSEMBLY. NOTIFY THE ARCHITECT OF ANY CONFLICTS. PROVIDE FUSES MANUFACTURED BY BUSSMAN, GOULD- SHAWMUT, OR LITTLE -FUSE. ALL FUSES 600 AMPERES OR LESS SHALL BE UL LISTED, CLASS RK1 OR J, LOW -PEAK, DUAL ELEMENT, TIME DELAY, 600 VOLT. VERIFY CONDITIONS AT SITE. CONFORM TO ALL APPLICABLE CODES AS REQUIRED. ALL REQUIRED PERMITS SHALL BE SECURED AND PAID FOR BY ELECTRICAL CONTRACTOR. UPON COMPLETION OF THE ELECTRICAL SYSTEM THE TENANT WILL HIRE AN INDEPENDENT CONTRACTOR /INSPECTOR TO VERIFY THE INSTALLATION. IN THE CASE OF DISCREPANCIES, THE CONTRACTOR WILL BE NOTIFIED IN WRITING TO CORRECT THE ERRORS. SHOULD THE TENANT DESIRE A REINSPECTION, THE COST OF A REINSPECTION (PLUS 10 %) WILL BE DEDUCTED FROM THE FINAL CONTRACT INVOICE. SERVICE FEEDERS AND CONDUIT TO LANDLORD PROVIDED FUSED DISC. SWITCH AT BACK WALL BY LANDLORD. (4- #4/0 -2 1/2"c. MIN.) EXISTING METER SOCKET AND METER TO REMAIN e NEW BREAKER 200 AMP CIRCUI _-.., �.. w�.� .� •.����„ -. _�...___ .w��?�' W . ' "rim°:.= ;; DAVID DAY, P.E. :x.'r:= ; ;:as p ���.b ������.- .,.,- ,..�r._._.� =� ����.�.��'a ;�'�r_...�•f`�; BEBE - SOLI A 1-7 CENTER Utility Fault Currert 200 AMP DISCONNECT SWITCH WITH 200 AMP FUSES MOUNTED ON BACK WALL OF TENANT SPACE BY LANDLORD. 1 kVAx 1000 = trans, FLA E x 1.732 Is = trans. FLAx 100 transformer Z !sea = ampere short circuit current FIVSsynrnalrical. Pant to Point Method 'f • factor M= 1 1 +f RUN NEW 4 - #4/O "THHN" 277/480V. 3PH, 4W. SERVICE IN 2 1/2" C. BACK WALL OF SPACE Q CONNECT TO WIRING 3- #4 -1 "C. Available Fault Length (dstance) 1.732 x L x 1 (ASC) N x C x E L -N # conductors per phase Phase conductor constant Volt Line to Line NEW 225 AMP 277/480V. PNL "A" W /200 AMP MAIN BREAKER NEW 45 KVA TRANSFORMER ON FLOOR RISER DIAGRAM NOTES 1. CONTRACTOR SHALL OBTAIN AVAILABLE FAULT CURRENT RATING AND PROVIDE PROTECTION FOR MAIN CIRCUIT BREAKER AND ALL BRANCH DEVICES AS REQUIRED. 2. CONTRACTOR TO MAINTAIN ALL REQUIRED CLEARENCES PER ARTICLE 110 -26 NEC POWER RISER DIAGRAM NOT TO SCALE ELECTRICAL LEGEND S-- T-S 3 S S S �I S 'a 11 C ) EX SINGLE POLE SWITCH 3 -WAY SWITCH DUPLEX WALL RECEPTACLE ISOLATED GROUND DUPLEX RECEPTACLE SINGLE WALL RECEPTACLE FLOOR RECEPTACLE QUADRAPLEX WALL RECEPTACLE JUNCTION BOX TELEPHONE OUTLET DATA OUTLET TELEPHONE CONDUIT PUSHBUTTON BUZZER TRANSFORMER CONDUIT ABOVE FLOOR CONDUIT BELOW FLOOR HOME RUN CONDUIT EXISTING TO REMAIN amperes kVA E trans. FLA Inca L N C E L- L f Neutral conductor constant C Multiplier Voit Line to Naftral E L - N f Line to Line Line to Neutral Fault Current at Service Equipment M M Inca x M = fault current at terminals of main dlscomect L - L = Isal X M = fault current at terminals of main dsconnect L- N = f- 4- #12 -1/2C. Cal ailation NEW 225 AMP 120/208V. PNL "B" W/125 AMP MAIN BREAKER DISCONNECT SWITCH r 4- (30/20, NEMA 1) NEW 225 AMP 120/208V. PNL "C" M -L -0 \ t 4- #4 -1 -1/4 C. -4-#1/0-2"C. 'L #6 GROUND TO BLDG. STEEL PER NEC Three Phase 480/277 Phase Conductor amperes amperes NEW VAV BOX Ver. 4.00 a Nil Conductorj 4/0 TR Volt RECEIVED CITY OF TUKWI:A AUG 2 7 2007 PERMIT CENTE9 LO1 DATE: Aug. 11, 2001 JOB NO: 01462$3 DRAWN: KC CHECKED: KC IA 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 REVISIONS BID/ PERMIT/ 1 LL. SUBMITTAL ELECTRICAL POWER RISER AND SPECS SHEET NUMBER STROBE PULL - STATIO (TYPICAL FO EXTEND AND C TO LANDLORD 3/4" CONDUIT gAmmM UMMM 1 1 FIRE ALARM NOTES: 1. PROVIDE WIRING IN ACCORDANCE WITH NEC, NFPA AND AS REQUIRED BY LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR AND ANY LOCAL AUTHORITIES WHICH MAY HAVE JURISDICTION. 2. FURNISH AND INSTALL A DUCT DETECTOR WITH REMOTE TEST SWITCH AND LED INDICATOR LIGHT IN HVAC UNIT, IF REQUIRED BY CODE OR BY THE AUTHORITY HAVING JURISDICTION. 3. THE TENANT SHALL USE ONLY LANDLORD DESIGNATED FIRE ALARM CONTRACTOR SPECIFIED EQUIPMENT TO ENSURE COMPATIBILITY WITH THE LANDLORD'S FIRE ALARM SYSTEM. 4. PROGRAMMING AND TESTING OF THE DEVICES AND SEQUENCE OF OPERATION SHALL BE BY THE LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR AT TENANT'S EXPENSE. 5. EACH TENANT'S FIRE ALARM SYSTEM SHALL BE FINAL TESTED BY THE LOCAL BUILDING AND FIRE MARSHALL AND WITNESSED BY LANDLORD'S ON-SITE REPRESENTATIVE. 6. REQUIRED FIRE ALARM CONTRACTOR: GUARDIAN SECURITY 9435 PROVOST ROAD NW SILVERDALE, WA 98383 PHONE: 360- 692 -3738 FAX: 360 - 692 -6857 EMAIL: BOB VEZZANI BVEZZANI @GUARDIANSECURITY.COM ADMIN: PONY MAURICE PMAURICE@GUARDIANSECURITY.COM FIRE ALARM PLAN va• - r.u• BEBE SPACE #1530 LEVEL 1 STOREFRONT ZONE: TYPE 2 PROJECT KEY PLAN NOT TO SCALE ELO14-1 REVIEWED FOR CODE NRA 70 - NEC ocl1 City �f TukWila B ILDING DIVISION b RECEIVED CITY OF TUKML AUG 2 7 2001 PERMIT CENTER DATE: Aug. 11, 2001 JOB NO: 0146283 DRAWN: KC CHECKED: KC OVA 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635-5699 REVISIONS 510/ PEWIT/ L.L. suemITTAL 8/1"1/2001 FIRE ALARM PLAN SHEET NUMBER