Permit EL07-514 - WESTFIELD SOUTHCENTER MALL - SKECHERS USA
SKECHERS USA 816 SOUTHCENTER MALL ELO7-514 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Value of Electrical: Type of Fire Protection: Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 816 SOUTHCENTER MALL TUKW SKECHERS USA 816 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA DANIELLE GRATIOT 80 S LAKE AV, STE 650 , PASADENA CA Contractor: Name: SIGN -TECH ELECTRIC LLC Address: 33759 NINTH AVE S , Contractor License No: SIGNTEL988BG DESCRIPTION OF WORK: NEW LIGHT FIXTURES AND INSTALLATION. INSTALLATION OF TELEPHONE AND DATA CABLES. NEW TRANSFORMER AND ELECTRICAL PANEL. $20,000.00 SPRINKLERS /AFA Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied Signature: Print Name: doc: EL -4/07 ELECTRICAL PERMIT -e_uLale,A, ( Permit Number: ELO7 -514 Issue Date: 03/10/2008 Permit Expires On: 09/06/2008 Expiration Date: Phone: Phone: 626 685 -2800 Phone: 253 952 6559 Fees Collected: National Electrical Code Edition: Date: ni 1(01 �$ ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo of work. I am authorised to sign and obtain this electrical permit. Date: $512.50 2005 sAele This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. EL07 -514 Printed: 03 -10 -2008 �sr►' City of Tukwila Parcel No.: 6364200010 Address: 816 SOUTHCENTER MALL TUICW Suite No: Tenant: SKECHERS USA 1: ** *ELECTRICAL * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: ELM-514 Status: ISSUED Applied Date: 09/20/2007 Issue Date: 03/10/2008 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or • e performance of work. Signature: Print Name: doc: Cond -Elec Date: — p- EL07 -514 Printed: 03 -10 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tukwila. wa. us Site Address: SotAiccntt'r )4411 effe Southrcni PoIrI4vay Tenant Name: SKechers USA Property Owners Name: WestFi l (orpori►}io Mailing Address: 114,01 Wilskiro glvol. l Floor Name: Dahjp,IIP. 6rattlo f Mailing Address: 00 5. ow Av . ,SIMIC 660 E -Mail Address: oilkotjloi y eGHirilanA0100145. £afri H: Applications\Fonns- Applications On Line\4 -2007 - Electrical Permit Application.doc bh Electrical Permit No. Project No. f01 ---1 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: Z6Z5O4 • '1'065 Suite Number: 1 140 Floor: 1 1A5 At eeS City J) New Tenant: IA Yes ❑ .. No CA State CONTACT PERSON — Who do we contact when your permit is ready to be issued Day Telephone: 626. GMl,. 100o Fas4dena CA 0 111 0 1 Cit State Fax Number: 626. 61'16 .14303 ELECTRICAL CONTRACTOR INFORMATION Company Name: T. 13. D. Mailing Address: Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State goo25 Zip Zip Valuation of Project (contractor's bid price): $ 90 i 000. n Scope of Work (please provide detailed information): MAO (AIM' F6140/3- # WIA hlllahm. (M/3tlleth; o1' telep'hohr, aw,d d41 Ci14(4 - . WPAO tram sfDrmpr aM.d .G{ttfri / ()Mtt( • Will service be altered? ❑ Yes d No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel d Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: IA Puget Sound Energy ❑ Seattle City Light Page 1 oft tip RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: /7 \ l Nw Ri t7 Print Name: TQVOL NA o( Day Telephone: Pb ■ti eb /k w4 `tR. City State Zip Mailing Address: 1,3Lf C- 14i?\ I Date Application Accepted: /AIZ H:Wpplications\Forms- Applications On Line - Electrical Permit Application.doc bh MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea Date Application Expires: jr 17,0 MISCELLANEOUS FEES Date: 69 /20/ 0 7 Staff Initials: 1 Page 2 of 2 Parcel No.: 6364200010 Permit Number: EL07 -514 Address: 816 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 09/20/2007 Applicant: SKECHERS USA Issue Date: Receipt No.: R08 -00675 Initials: JEM User ID: 1165 Payee: SIGN -TECH ELECTRIC LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 5637 410.00 ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000.322.101.00.0 410.00 Total: $410.00 Payment Amount: $410.00 Payment Date: 03/10/2008 12:28 PM Balance: $0.00 9667 03/10 9710 TOTAL 410.00 rinn RAneint -06 Printcat 03- 10 -90OR Receipt No.: R07 -02038 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /wvw.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049023 Permit Number: EL07 -514 Address: 633 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 09/20/2007 Applicant: SKECHERS USA Issue Date: Initials: JEM Payment Date: 09/20/2007 10:41 AM User ID: 1165 Balance: $410.00 Payee: CHIPMAN ADAMS PACIFIC ARCHITECTURE PC TRANSACTION LIST: Type Method Description Amount Payment Check 3739 102.50 Account Code Current Pmts 000.345.832.00.0 102.50 Total: $102.50 Payment Amount: $102.50 1014 ,9/20 C7iOO TOTAL 102.50 dm! Renoint -CM Printed! 09 -70 -2007 prgj � G r/4J � � � Type of Inspection: /� 1 Ad re // s � s: c /� Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 proved per applicable codes. Corrections required prior to approval. COMMENTS: 0/4 1/0 (Insp `L &7-tAmi/6.# EJ $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Date: s/4 _ _ /e,r. COMMENTS: 11) i dAAXlf Y MA //l) / ?t E, A) Cill. AWN P//Z POLSTr/f-L6 S 2A✓ A S V 1 colljI F &21‘s 1- i6117741 ilk /,'C - Adf- -/LA66 f Foor 'V'[ -F_ 117 f uo/'' 44-0/VG 'AtriRt F-&2 sS th7T///'VAY Ik/A b/SGYfKGE 3� coNr n1J inKr!? //01 /N u-- Armit p G/ /AAIcE -6E0E4 44/11 70 t411 /°6i Special Instructions: at. 7 G01f1_4 -- STOG ?/2orf'I r21 14)C- ` a.m. p.m. p(rojeCUtGHeiL( Type of Inspection: < -1 Address: �/� �uTJfGA/L7-' //- Date Called: Special Instructions: Date Wanted: I// ` a.m. p.m. Requester: Phone No: f<07- - ]9 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION K" 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. 1 1 c orrections required prior to approval. r Inspe r: /it g nw1 // Date: $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Pgri e.....fri 4/4 Type of Insp ,5 AZ;e5s: ,•.- _ /Ph 6 IfiTA / )7°, k Date Called: Special Instructions: Date Wanted: v a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3 C MMENTS: oA- siAwc6 .01 01/ 11 G-/L proved per applicable codes. El Corrections required prior to approval. Inspecr Twiya N Date: El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: !Date: Pro'ec : ��► / - C �^ Type of Inspection: /(Jl /� Address: /� Date Called: Special Instructions: Date Wanted: �/ 1 a.m. p.m. Requester: �/ Phone No: INSPECTION RECORD Retain a copy with permit ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION l 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 EI Approved per applicable codes. Corrections required prior to approval. COMMENTS: og- / AtTENK koi_Lc Ins ``` £7iizQAgN I DI $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Pro t-ii as . Type of Inspection: rs s: , A §/& 36w7YeAti a tt. Date Called: Special Instructions: Date Wanted: 7774 P.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION `i?. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 206 431- OMMENTS: 01Z 4'N1\0SL4& fo0A 2o7e-s 4A1N proved per applicable codes. Corrections required prior to approval. 47-4m I Date: V, 1:1 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. !Receipt No.: 'Date: COMMENTS: / W/ CK — Lt GJl/ — E/1ST W G /9t-S DNG}/ Date Wanted: /� !/ 0 SEAVI - ft(S.e. A /SGDrv,/tc 7 /9 T 70 /9 7Y col,t- Y IA/ /77/ NI c- ys Phone No: i i Proje t: S 4-UlE11S UfS4 Type of Inspection: 70M�703 Date Called: Add & ,4fritet/era A 14 Special Instructions: Date Wanted: /� !/ :m. m. Requester: Phone No: 1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 12 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 pproved per applicable codes. INSPECTION RECORD Retain a copy with permit 1E1-07-S2 rrections required prior to approval. 'Inspec ju/ k _ ''/ f' , /71 Dat 7 fic( $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 100A7OS - Adjustable Downlight, (1)70 -W MH, Electronic E 12 86.0 1032.0 100A70W - Adjustable Downlight, (1)70 -W NH, Elect. Ballast 2 86.0 172.0 100B70W - Adjustable Downlight, (2)70 -W MH, Elect. Ballast 3 172.0 516.0 100 D170W - Track Head, (1) 70 -W NH, Electronic Ballast 7 86.0 602.0 100E32S - Downlight, (1) 32 -W TRT, Electronic Ballast 3 35.0 105.0 100E32W - Downlight, (1) 35 -W TRT, Electronic Ballast 3 35.0 105.0 100S - LED Strip Light, 2 -W Per Linear Foot 84 2.0 168. 0 100G70ALU - Suspended Pendant, (1) 25 -W CPL, Elect. Ball 5 28.0 140.0 102H32 - 4' Strip Light, (1) F32T8, Electronic Ballast 23 32.0 736.0 103K - Pan /Light, 100 -W, Incandescant 1 100.0 100.0 100Track - 30 -W Per Linear Foot 40 30.0 1200.0 Location (floor /room no.) Occupancy Description Allowed Watts per e- Area in ft Allowed x Area 101, 102, 103 Retail 1.50 2413.0 3619.5 100 Retail - Table 15 -1, Footnote 10 (Track & D170W) 1.50 1208.0 1812.0 2006 Washington State Nonresidential Energy Code Compliance Forms Interior Lighting Summary LTG -INT : 0 o.: mentp A� °EC 1 1 1001 iIa 1 N , C Project Info Project Address Skachers Tukwila, WA Westfield Southcenter Mall Tukwila, WA 98188 Applicant Name: Applicant Address: Applicant Phone: Project Description Date For Building Dep O New Building 0 Addition ® Alteration 0 Plans Inciud Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive • Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) O No changes are being made to the lighting 0 Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage From Table 15 -1 (over) - document all exceptions on form LTG-LPA Proposed Lighting Wattage 2006 Washin ton State Nonresidential Ener Code Com•Iiance Form Total Proposed Watts may not exceed Total Allowed Watts for Interior Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. RECEIVED CITY OF TUKWILA NOV 1 3 2007 FILE COPrRMITCENTR Total Allowed Watt 5431.5 Total Proposed Watt sl 4876.0 CORRECTION Gig Use' LPA` (W /sf) Use' LPA (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations 1.0 Cafeterias, fast food establishments restaurants/bars 1.3 Post office 1.1 Dormitory 1.0 Retail retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses'', storage areas 0.5 Hotel banquet/conference /exhibition hall 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occu an P cy: 0 Warehouses, storage areas or aircraft storage hangers p Other Qualification Checklist Note: If occupancy type Is "Other and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) r Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballas 3. LED lights. Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Form TABLE 15 -1 Unit Litahtina Power Allowance (LPA 2006 Washin ton State Nonresidential Ener Code Corns Hance Form Revised July 2007 s Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three- quarter - height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Lighting, 2008 Washington State Motor, and Transformer Permit Plans Checklist LTG -CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Skechers Tukwila, WA 'Date 8/10/2007 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) I Code Section Component Information Require( Location on Plans Budding Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations E2 yes 1513.2 Area controls Maximum limit per switch E2 yes 1513.3 Daylight zone control Schedule with type and features, indicate locations E2 yes vertical glazing Indicate vertical glazing on plans E2 n.a. overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib /special Indicate separate controls E2 1513.5 Exterior shut -off Schedule with type and features, indicate location n.a. (a) timer w /backup Indicate location n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location n.a. 1513.6.1 (a) occup. sensors Schedule with type and locations n.a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans yes 1513.7 Commissioning Indicate requirements for lighting controls commissioning 82 EXIT SIGNS (Section 1514) yes 1514 'Max. watts Indicate watts for each exit sign LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture type lamps, ballasts, watts per fixture n.a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) n.a. ' 1511 'Elec motor efficiency' MECH -MOT or Equipment Schedule with hp, rpm, efficiency I ' TRANSFORMERS (Section 1540) n.a. I 1540 'Transformers 'Indicate size and efficiency 1 ' 2006 Washington State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: 2006 Washin ton State Nonresidential Ener Code Compliance Form Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of tuming off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1613.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of tuming off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting riot designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during Toss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically tuming off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of tuming off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low- light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft or 5% of the building footprint for footprints over 100,000 ft whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or Tess per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class 1 Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP -1- 2002). 9nnA Wachinatnn Ciaic Alnnrncirluntial Fncrnv (`.nrio nrImnlianen Fnrm EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or Cooling Equipment Schedule Equip. ID Brand Name Model No. Capacity2 Btu/h Total CFM OSA CFM or Econo? SEER or EER IPLV Location VAV -1 CARRIER 45J NA 2750 NA NA NA CEILING Fan Equipment Schedule Equip. ID Brand Name' Model No.1 CFM SPt HP /BHP Flow ControP Location of Service VAV -1 CARRIER 45J 2750 34100 (2) 0.75 VAV CEILING 34100 97.000 Heating Equipment Schedule Equip. ID Brand Name Model No 1 Capacity2 Btu/h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiencv VAV -1 CARRIER 45J 34100 2750 34100 34100 97.000 Project Info Project Address Skechers Tukwila, WA Date 8/10/2007 Westfield Southcenter Nall For Building Dept. Use Tukwila, WA 98188 Applicant Name: Applicant Address: Applicant Phone: Mechanical Summary • MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. Indudes Plans 2006 Washin ton State Nonresidential Ener Code Como Hance Form Revised July 2007 Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Compliance Option Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the 1 plans. For projects without plans, fill in the required information below. t lf available. 2 As tested according to Table 14 -1A through 14 -1G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). System Description If Heating /Cooling E Constant vol? • Air cooled? • Packaged sys? • <20,000 Btuh? See Section 1421 for full description or Cooling Only: j Split system? Economizer included? • of Simple System qualifications. if Heating Only: 0 <5000 cfm? • <70% outside air? Mechanical Summary (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. 2006 Washin ton State Nonresidential Ener Code Com•liance Form otal Ca . wo economize <24Q000 Btuh r 10 %? Heating Only ( Reference Section 1421 J Heating/Cooling or Cooling Only Reference Sedan 1423 Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical 2006 Washington State Nonresidential Permit Plans Energy Code Compliance Forms Checklist MECH -CHK Revised July 2007 Project Address Skechera Tukwila, WA Date 8/10/2007 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) I Code Section Component Information Requirec Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n. a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency M n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yea 1412.1 Temperature zones Indicate locations on plans M1 yes 1412.2 Deadband control Indicate 5 degree deadband minimum M3 n.a. 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 Jiff. day types M3 yea 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage MI- n.a. 1412.4.2 Optimum Start Indicate optimum start controls n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans M1 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas yes 1422 Thermostat interlock Indicate thermostat interlock on plans Mi n.a. 1423 Economizers Equipment schedule 1413 Air economizers n.a. 1413.1 Air Econo Operation Indicate 100% capability on schedule no 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance n.a. 1413.3 Integrated operation Indicate capability for partial cooling n.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yea 1414.1 Duct sealing Indicate sealing necessary M1M3 yea 1414.2 Duct insulation Indicate R -value of insulation on duct n.a. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements yea 1416.2.1 Commissioning Provide commissioning plan M3 yea 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing M3 no 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training yes 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report M3 n. a. 1434 Separate air sys. Indicate separate systems on plans yes !Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. n.a. 1441 Elec. water heater Indicate R -10 insulation under tank n.a. 1442 Shut -off controls Indicate automatic shut -off yea 1443 Pipe Insulation Indicate R -value of insulation on piping P3 n.a. 1452 Heat Pump COP Indicate minimum COP of 4.0 12.41. 1452 Heater Efficiency Indicate pool heater efficiency n . a . 1453 Pool heater controls Indicate switch and 65 degree control 6.41. 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14-1A through 14-1G. If a nationally recognized certification program exists for a product covered in Tables 14-1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air fumaces with input ratings > 225,000 Btu/h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable altemative to a flue damper for fumaces where combustion air is drawn from the conditioned space. All fumaces with input ratings > 225,000 Btu/h (65 kW), including electric fumaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be fumished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or altemate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full bad demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stones in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings 1412.8 Ventilation Controls for High - Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is Tess than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and retum air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and intemal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14-1A through 14-1G. If a nationally recognized certification program exists for a product covered in Tables 14-1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air fumaces with input ratings > 225,000 Btu/h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable altemative to a flue damper for fumaces where combustion air is drawn from the conditioned space. All fumaces with input ratings > 225,000 Btu/h (65 kW), including electric fumaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be fumished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or altemate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full bad demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stones in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings 1412.8 Ventilation Controls for High - Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is Tess than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and retum air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and intemal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 7. V10VIly ,IIVIIIIIVWIKCY� MV� I� CIa'gAigtho ,§gtanclate%jgentia i.Etlergy.Code Compliance.Earm outlets in the first story and levels below the first story of buildings duct runs are considered building envelope until they, three or more stories in height. 1. connect to the heating or cooling equipment, or 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2. are isolated from the exterior with an automatic shut -off damper complying air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum with Section 1412.4.1. start controls shall be designed to automatically adjust the start time of an HVAC Once outside air ducts meet the above listed requirements, any runs within system each day to bring the space to desired occupied temperature levels conditioned space shall comply with Table 14-5 requirements. immediately before scheduled occupancy. The control algorithm shall, as a Other ducts and plenums shall be thermally insulated per Table 14 -5. minimum, be a function of the difference between space temperature and occupied Exceptions: setpoint and the amount of time prior to scheduled occupancy. 1. Within the HVAC equipment. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set- 2. Exhaust air ducts not subject to condensation. up, and defrost conditions. These controls shall anticipate need for heat and use 3. Exposed ductwork within a zone that serves that zone. compression heating as the first stage of heat. Controls shall indicate when 1415 Piping Systems supplemental heating is being used through visual means (e.g., LED indicators). 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment Exception: Piping installed within unitary HVAC equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion Water pipes outside the conditioned space shall be insulated in accordance with control. 000 Washington State Plumbing Code (WAC 51 -26) EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1416 Completion Requirements (Refer to NREC Section 1416 and the Building 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have Commissioning Guidelines, published by the Building Commissioning Association, a means for balancing, including but not limited to, dampers, temperature and for complete text and guidelines for building completion and commissioning pressure test connections and balancing valves. requirements.) 02 -12 -2008 DANEILLE GRATIOT 80 S LAKE AV, STE 650 PASADENA CA 91101 RE: Permit Application No. EL07 -514 816 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 09/20/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 03/18/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 03/18/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: 4 d1)291 er Marshall 't Technician Permit File No. EL07 -514 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 October 22, 2007 Danielle Gratiot 80 S Lake Ave Suite 650 Pasadena CA 91101 RE: CORRECTION LETTER #1 Electrical Permit Application Number EL07 -514 Skechers — XXX Southcenter Mall Dear Ms. Gratiot, This letter is to inform you of corrections that must be addressed before your electrical permit can be approved. All correction requests from the Building Department must be addressed and reflected on your drawings. Building Department: Bill Buterbaugh, at 206 937 -4758, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that three (3) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincere LtivCtv`. • Bill Rambo Permit Technician encl xc: File No. EL07-5 14 P:\Pemrit Center\Correction Letters \2007\EL07 -514 Comction Ltr # 1.DOC wer City of Tukwila Department of Community Development Steve Lancaster, Director 0 Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 JB'S ELECTRICAL PLAN REVIEW COMMENTS CITY OF TUKWILA Electrical Permit # ELE07 -514 Date October 16, 2007 Status: The following items are needed in order to complete plan review. Also items to be attached or marked on the final plans. Number Comments ITEMS NEEDED FROM PERMIT APPLICANT 1. The load calculation submitted for panelboard "L" is 82.9 amperes, the transformer allowable ampacity is 83.3 amperes. This transformer has only .4 amperes for errors or omissions. 2. Provide a panelboard schedule and load calculation for 200 ampere 480 volt panelboard serving the transformer. Also include panelboard identification for this panel. 3. The transformer secondary overcurrent protection exceeds what is allowed per Article 450. The next standard size circuit breaker is 110 amperes. 4. Include in the electrical legend the lighting fixture symbols. 5. The transformer cannot be located below panelboard "L ". ITEMS TO BE RED LINED OR ATTACHED TO FINAL PLANS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL07 -514 DATE: 11 -14 -07 PROJECT NAME: SKECHERS USA Slln SITE ADDRESS: SOUTHCENTER MALL, Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: MG Bui ing Division Public Works ❑ Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Fire Prevention Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: ,PERMIT COORD COPY n ❑ Permit Coordinator DUE DATE: 11-15-07 Not Applicable E No further Review Required DATE: Planning Division DUE DATE: 12 -13-07 Not Approved (attach comments) DATE: n C n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: EL07 -514 DATE: 09 -20 -07 PROJECT NAME: SKECHERS USA SITE ADDRESS: XXX SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS:. a.0) Buifdli g Clvi Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES/THURS ROUTING: Please Route it Structural Review Required REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete ❑ Planning Division ❑ Permit Coordinator n DUE DATE: 09-5-07 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 10-23-07 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 10-0V- _O 7 Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: "mot City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.cltukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director 1 REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 11 -07 -07 Plan Check/Permit Number: EL07 -514 ❑ Response to Incomplete Letter # El Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner RECEIVED CITY OF MO IRA NOV 1 20071 PERMIT CEtJTE Project Name: Skechers USA Project Address: XXX Southcenter Mall, Suite 1140 Contact Person: Danielle Gratiot Phone Number: 626.685.2800 Summary of Revision: Response 1: The transformer size was revised to have additional amperes for errors or omissions. Response 2: A panelboard serving the transformer is not necessary due to the existing disconnect serving the transformer. Response 3: The transformer and panel breaker size were revised to comply with Article 450. Response 4: The lighting fixture symbols have been added to the electrical legend on sheet E -3. Response 5: Panel "L" has been relocated to the right of the transformer and is no longer above the transformer. Sheet Number(s): E -1, E -2 & E -3 "Cloud" or highlight all areas of revision including date of r ' ision Received at the City of Tukwila Permit Ctnter by Entered in Permits Plus on \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: License Information License SIGNTEL988BG Licensee Name SIGN -TECH ELECTRIC LLC Licensee Type ELECTRICAL CONTRACTOR UBI 602152490 Ind. Ins. Account Id Business Type LIMITED LIABILITY COMPANY Address 1 5113 PACIFIC HWY E #12 Address 2 City FIFE County PIERCE State WA Zip 98424 Phone 2539222146 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/7/2002 Expiration Date 1/7/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License MORRIT *943K6 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Electrical Administrator Information License Name Status MORRIT *943K6 MORRISON, TRAVIS ACTIVE Business Owner Information Name MENDENHALL, JOHN C Role PARTNER/MEMBER Effective Date 01/07/2002 Expiration Date MENDENHALL, LINDA D PARTNER/MEMBER 01/07/2002 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= SIGNTEL988BG 03/10/2008 0 SCALE' 1/4' =1' -0' SCALE' N.T.S. NOTE 27 - -, (25/3 NOTE 15 STOCKROOM VAV -1 \ ,1 / ' a; 1 1 r.1 \ i:: 3 ,/ , 1 .^ 3 / <V. / ;V V \ 1 1 c:+ \ \ I \ -��� ._. 1 •iH I I / n4 }S' L _ 1' x =ps' U _ 1 1 x45' ._ 12 A i -- i OTE 14 NOTE 11 NOTE 10 NOTE 13 (TYPICAL) L -12, 07A 77MECLOCK) NOTE 2 SALES FLOOR tj L-2Z29 EXISTING ELECTRICAL ROOM - NOT IN SCOPE OF WO. T -1" EXISTING STORAGE ROOM - NOT IN SCOPE OF WORK NOTE 17 PANEL - TRANSFORMER GENERAL NOTES TR NOTE 23 NOTE 19 L -28 NOTE 16 102 Nil 1. RE I <11L1N1 POWER & SYSTEMS PLAN A . EXISTING CONDI TIONS SHOWN ARE BASED ON AS -BUILT DRAWINGS PROVIDED BY THE OWNER AND L IMI TED FIELD VERIFICATION. CONTRACTOR SHALL ADJUST FOR ACTUAL FIELD CONDI TIONS A T NO ADDITIONAL EXPENSE TO THE OWNER. B. ALL NEW POWER AND LIGHTING CONDUI TS ON THIS PROJECT SHALL INCLUDE AN INSULATED GREEN EQUIPMENT GROUNDING CONDUCTOR SIZED AS NOTED OR PER NEC WHERE NOT NOTED. THIS GROUNDING CONDUCTOR SHALL BE PROVIDED REGARDLESS OF THE TYPE OF CONDUIT USED. C. CONTRACTOR SHALL FAMIL IARIZE HIMSELF WITH 77E DEMOL I TION WORK PRIOR TO BIDDING AND START OF WORK. CONTRACTOR IS RESPONSIBLE TO DEMOL ISH ALL EXISTING AS REQUIRED TO ALLOW FOR INSTALLATION AND CONSTRUCTION OF NEW WORK. D. THIS PLAN IS INTENDED TO CONVEY THE SCOPE OF THE WORK TO BE COMPLETED. REMOVE ALL EQUIPMENT, DEVICES, FIXTURES, CONDUI TS, SUPPORTS, HANGERS, ETC NOT SHOWN THAT ARE REQUIRED TO BE REMOVED IN ORDER TO COMPLETE THE NEW WORK. RECESSED BOXES AND CONDUITS CONCEALED WI THIN WALLS OR FLOORS THAT ARE TO REMAIN MAY BE ABANDONED IN PLACE AS LONG AS THE OPENINGS ARE PATCHED AND THE CONDUCTORS REMOVED . E. IT IS 77E RESPONSIBI I TY OF THE CONTRACTOR TO DISPOSE OF ALL EQUIPMENT NOT REUSED AS PART OF THE NEW WORK. THE OWNER SHALL HAVE FIRST SAL VAGE RIGHTS ON ALL MATERIALS AND EQUIPMENT. ADJANCENT TENANT - NOT IN SCOPE OF WORK F. MAINTAIN CONTINUI TY OF CIRCUITS AS NEEDED TO PROVIDE POWER TO REMAINING DEVICES, FIXTURES, OR EQUIPMENT NOT BEING REMOVED UNDER THIS PLAN. G. ASSUME THAT ALL EXISTING ELECTRICAL NOT SHOWN AS REMAINING ON THESE SHEETS IS TO BE DEMOL /SHED. IF SOME EXISTING I TEMS NOT SHOWN ARE DEEMED TO BE NECESSARY FOR PROPER OPERATION OF THE FACIL I TY, VERIFY WITH THE OWNER, ENGINEER, OR LANDLORD BEFORE PROCEEDING WI TH DEMOL I TION. EXERCISE CARE TO NOT DEMOL ISH ANY I TEMS THAT ARE PART OF THE MALL 'S MEP SYSTEMS. H. COMBINATION PHONE /DATA LOCA TIONS ARE TO BE PROVIDED AS ROUGH IN LOCATIONS WITH CABLE INSTAL/ FD SEE SPECIFICATIONS FOR CABLING REQUIREMENTS. INSTALL THESE ROUGH IN LOCATIONS AS SHOWN ON TIE TYPICAL ROUGH IN DETAIL SHOWN ON SHEET E -3. 1. CONDUI TS SHOULD EXTEND UNTIL THEY ARE WI THIN THE OPEN CEILING AREA OF THE STOCK ROOM. ALL CABLE IS TO BE PLENUM I. THIS PROJECT UTILIZES A PLENUM RETURN AIR CEIL ING DESIGN. ALL EQUIPMENT AND MATERIALS INSTALLED IN THE PLENUM RETURN CEILINGS MUST MEET THE FLAME SPREAD AND SMOKE DEVELOPED RATINGS OF 2.5/50 AND BE APPROVED FOR USE IN PLENUM RETURN CEIL INGS. EXISTING 1 HR. SERVICE CORRIDOR - NOT IN SCOPE OF WORK U SCALE' N.T.S. 103 OFFICE AREA 7" 4'-31 1. PROVIDE A SURFACE MOUNTED PUSH BUTTON FOR "CALL FOR AID" 14. PURPOSES. VERIFY LOCATION WI TH OWNER. VERIFY REQUIREMENTS WI TH MANUFACTURER. 2. CONDUIT FOR CASHWRAP POWER AND TELECOM SHALL BE ROUTED 15. WI THIN CASHWRAP MILLWORK. COORDINATE INSTALLATION WI TH GENERAL CONTRACTOR. RUN FLEXIBLE METALL IC CONDUI T WI THIN THE 16. CASHWRAP MILLWORK FROM OUTLET TO OUTLET. 3. PROVIDE ISOLATED GROUND QUADRUPLEX RECEPTACLES INSIDE TALL 17. CABINETS OF CASHWRAP MOUNTED AT *12" A . F. F. 4. SPEAKER VOLUME CONTROL MOUNTED TO WALL BEHIND CASHWRAP PROVIDED BY A/V VENDOR. 5. PROVIDE A SINGLE STROKE CHIME MOUNTED AT +96 " A . F. F. USE AN EDWARDS #338 -G5 OR EQUIVALENT. CONNECT TO DOOR BUZZER TRANSFORMER VIA PLENUM RATED LOW VOL TAGE CABLE FOR A FULLY FUNCTIONAL SYSTEM. CONCEAL WI THIN THE WALL UP TO THE ACCESSIBLE CEIL INC. IF POSSIBLE. ' ` " 18. 6. PROVIDE A SURFACE MOUNTED PUSH BUTTON AT +48" A. F. F. FOR DOOR BUZZER. USE EDWARDS #632L OR EQUIVALENT. 19. 7. NEW THERMOSTAT AND SENSORS FURNISHED BY LANDLORD AND INSTALLED BY TENANT AS SHOWN ON PLAN. 20. 8. CONDUIT IN FLOOR FOR POWER AND DATA TO CASHWRAP. 9. QUADRUPLEX RECEPTACLE FOR SERVER CABINET MOUNTED AT +48" A.F.F. 10. QUADRUPLEX RECEPTACLE FOR A/V EQUIPMENT MOUNTED AT +48" A . F. F. 11. DUPLEX RECEPTACLE FOR FAX MOUNTED AT + 15" A . F. F. 12. DUPLEX RECEPTACLE FOR RFFRIGERA TOR AND MICROWAVE MOUNTED AT 21. +15" A . F. F. 13. CONTRACTOR TO PROVIDE DUPLEX RECEPTACLE AND JUNCTION BOX CENTERED HORIZONTALLY AND VERTICALL Y ON THE BACK OF THE LIGHT BOX, PROVIDE FINAL CONNECTION FOR LIGHT BOX. ELECTRICAL NOTES 8' -0 REVISIONS No changes shall be ma "de to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 10' APPROVED Pi ^.N.T ,^.>,;C `.PECIF CATIr1MS ST 1L t 1 r .3 'ANGEL), MODIFIED OR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING OFFIcc!AL ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND IS ;U3.20T TO FIELD INSPECTIONS. PROVIDE A CEIL ING - MOUNTED JUNCTION BOX FOR SIGN. THE CIRCUI T FOR THE SIGN SHALL HAVE A DEDICATED GROUND AND NEUTRAL . DO NOT SHARE 77E NEUTRAL OR GROUND WITH ANY OTHER CIRCUIT. DUPLEX RECEPTACLE MOUNTED ABOVE GLAZING' FOR SHOW WINDOW POWER PER NEC 210.62. DEDICATED QUADRUPLEX RECEPTACLE MOUNTED NEAR SECURI TY ALARM SYSTEM ON TELEPHONE BOARD. TELEPHONE BOARD. PROVIDE A GROUNDING BAR ON THE BOARD WI TH A #6 GROUND WIRE TO THE GROUND BUS OF PANEL 1" . TENANT SHALL PROVIDE AND INSTALL A COMPLETE TELEPHONE SERVICE SUPPORT FACIL I TIES AS REQUIRED BY THE SERVING TELEPHONE COMPANY. ALL TENANT TELEPHONE EQUIPMENT SHALL BE CONTAINED WI THIN THE DEMISED PREMISES UT IL IZING LANDLORD SUPPL IED CABLE TRAY. ANY CORRIDOR WALL PENETRATIONS WILL NEED TO BE FIRE CAULKED AS REQUIRED DUPLEX RECEPTACLE AT +15" A . F. F. , FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. SECURITY ALARM CONTROL BOX MOUNTED TO TELEPHONE BACKBOARD BY ALARM VENDOR. VERIFY LOCATION WI TH ALARM VENDOR. ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL TWO 3/4 INCH CONDUITS FROM SERVER CABINET TO CASH DESK AND TWO 3/4 INCH CONDUITS FROM PHONE BOARD TO SERVER CABINET. WI THIN EACH CONDUIT FROM SERVER TO CASH DESK, GENERAL CONTRACTOR SHALL SUPPLY AND INSTALL FOUR CAT 5 CABLES. A TOTAL OF EIGHT CABLES TO TERMINATE AT CASH DESK LOCATION WITH FOUR RJ-45 DATA PORTS (COLOR: BLUE) PUNCHED WI TH A T568B CONFIGURATION. PROVIDE JUNCTION BOXES FOR CONNECTION OF CASHWRAP POWER, PHONE AND DATA WIRING. CORRECTION LTR# Plan review e pr+d affect to anon IIIMedan& Approval of construction documents damsel sulhodse the violation Of sew adopted code Irpnineoce. Receipt Of approved Reid Cow amicondlione iR City of *Mai BUILDING DIVISION G/ NOTE 15 (TYPICAL) Public Works, Building Division PERMIT NUMBER LEGEND EX /STING NEW WORK NEW TO EXISTING CONNECTION Iz/47 RECEIVED CITY OF TUKWILA NOV 1 3 20+]1 Fasmi T CENTER REVIEWED CODE COMPLIANCE NFPA 70 - NEC DEC 1 1 iU07 22. PROVIDE A JUNCTION BOX MOUNTED ON INSIDE WALL NEAR THE LOCATION OF THE EXTERIOR SIGNAGE. PROVIDE ONE 20A CIRCUI T FOR THE ILL UMINA TED SKECHERS "5" LOGO AND ONE 20A CIRCUI T FOR THE ILLUMINATED "SKECHERS USA /FOOTWEAR OUTLET" SIGN. EACH CIRCUIT SHALL HAVE A DEDICATED GROUND AND NEUTRAL . DO NOT SHARE THE NEUTRAL OR GROUND WI TH ANY OTHER CIRCUITS. 23. DOOR BUZZER TRANSFORMER. PROVIDE AN EDWARDS #599 OR EQUI VALENT AND CONNECT TO CHIMES AND BACK DOOR PUSH BUTTON VIA PLENUM RATED LOW VOL TAGE CABLE FOR A FULLY FUNCTIONAL SYSTEM. MOUNT TRANSFORMER NEAR THE EXISTING ELECTRICAL PANEL . POWER FROM CIRCUIT SERVING THE LIGHTING CONTACTORS. 24. CONTRACTOR SHALL PROVIDE DUPLEX RECEPTACLE FOR PLASMA MONITOR AT +7 '-4 " A.F.F. VIDEO FED FROM OFFICE LOCATION 25. TELEPHONE JACK FOR FAX MACHINE BY OWNER. ROUGH -IN LOCATION AND CABL ING BY ELECTRICAL CONTRACTOR. 26. VOICE AND DATA JACKS ARE BY OWNER. ELECTRICAL CONTRACTOR SHALL PROVIDE ROUGH -IN LOCATIONS AND CABL INC. 27. 4-POLE , SINGLE THROW, 24 HOUR TIME CLOCK FOR CONTROL OF STORE FRONT SIGN. 28. PROVIDE A DUPLEX RECEPTACLE FOR THE WATER DISPENSER MOUNTED AT +15" A.F.F. 29. CONNECT EXHAUST FAN TO SWITCHED SIDE OF RESTROOM LIGHT SWI TCH, SEE SHEET E -2. 1 FOR SWITCH LOCATION. 30. CABLE RECEPTACLE AT CEILING FOR VIDEO CABLE. A/V VENDOR TO PROVIDE ONE CABLE PER MONI TOR, FED FROM A/V EQUIPMENT IN OFFICE LOCATION. A/V VENDOR SHALL PROVIDE VIDEO CABL ING AND DEVICE. ROUGH -IN LOCATION BY ELECTRICAL CONTRACTOR. PiLE COPY. Schnackel m NewYork a Omaha a LasAngeles ti 800 wwwschnsckeLcom J J W CO = e0 co CO oa W W W Ci)1 Revisions Q ISSUE TO LANDLORD 07 -06 -07 L REVISION PER LANDLORD 08 -10 -07 L REVISION PER LANDLORD 09 -10 -07 ISSUE FOR PERMIT 09 -10 -07 REVISION PER CITY 11-05-07 EXPIRES 1 2/21/07 ARCHITECT I IE'Ef'8T rERIW7 NAT TMESE RAE HAVE YEBI PRE- PARED MEI NT SUPERVISIN THAT TO ME 3EST OF 11! KNEHLE IN, ME SAME C[.IPLY VIM ALL RILES, :GLATII S ma IREDIAICES 11,1101.11. 161 RELATING TO moms AND BWLDINGS. Drawn By CBW Scale 1/4' =1' -0° Job0 -9110 Sheet No. E-i Checked By SME Date 09 -10 -07 1 EXISTING ELECTRICAL ROOM - NOT IN SCOPE OF WORK 18 I x4t G70ADJ — L-15 L -17 D170W D17OW n n D17OW D170W D17OW D17OW ■ ■ G70ALCJ` L -11 • E 25 SALES NL FLOOR EM D170W G7OALU D170W D170W A OS L— • D OW D GENERAL NOTES SCALD N.T.S. . NE: W _. RESrROOM EXISTING 1 HR, SERVICE CORRIDOR - NOT IN SCOPE OF WORK ADJANCENT TENANT - NOT IN SCOPE OF WORK c A . EXISTING CONDI TIONS SHOWN ARE BASED ON AS —BUILT DRAWINGS PROVIDED BY THE OWNER AND L IMI TED FIELD VERIFICA TION. CONTRACTOR SHALL ADJUST FOR ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. B. ALL NEW POWER AND LIGHTING CONDUI TS ON THIS PROJECT SHALL INCLUDE AN INSULATED GREEN EQUIPMENT GROUNDING CONDUCTOR SIZED AS NOTED OR PER NEC WHERE NOT NOTED. THIS GROUNDING CONDUCTOR SHALL BE PROVIDED REGARDLESS OF THE TYPE OF CONDUIT USED. C. LIGHTING FIXTURES MARKED "E" ARE EXISTING FIXTURES THAT ARE TO REMAIN IN PLACE. L IGHTING FIXTURES THAT ARE MARKED "R" ARE EXISTING FIXTURES THAT HAVE BEEN REL OCA TED. REL OCA TED FIXTURES SHALL BE STORED, THOROUGHLY CLEANED, PLACED INTO THE REMODELED AREA , RECONNECTED, AND RELAMPED. EXISTING FIXTURES WITHIN 77-1E L IMI TS OF CONSTRUCTION SHALL BE THOROUGHLY CLEANED AND RELAMPED. D. CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE DEMOL I TION WORK PRIOR TO BIDDING AND START OF WORK. CONTRACTOR IS RESPONSIBLE TO DEMOLISH ALL EXISTING AS REQUIRED TO ALLOW FOR INSTALL4 TION AND CONSTRUCTION OF NEW WORK. E. THIS PLAN IS INTENDED TO CONVEY THE SCOPE OF THE WORK TO BE COMPLETED. REMOVE ALL EQUIPMENT, DEVICES, FIXTURES, CONDUI TS, SUPPORTS, HANGERS, ETC NOT SHOWN THAT ARE REQUIRED TO BE REMOVED IN ORDER TO COMPLETE THE NEW WORK. RECESSED BOXES AND CONDUI TS CONCEALED WITHIN WALLS OR FLOORS THAT ARE TO REMAIN MAY BE ABANDONED IN PLACE AS LONG AS THE OPENINGS ARE PATCHED AND 77-/E CONDUCTORS REMOVED. F. IT IS THE RESPONSIBIL I TY OF THE CONTRACTOR TO DISPOSE OF ALL EQUIPMENT NOT REUSED AS PART OF THE NEW WORK. THE OWNER SHALL HAVE FIRST SALVAGE RIGHTS ON ALL MATERIALS AND EQUIPMENT. G. MAINTAIN CONTINUITY OF CIRCUITS AS NEEDED TO PROVIDE POWER TO REMAINING DEVICES, FIXTURES, OR EQUIPMENT NOT BEING REMOVED UNDER THIS PLAN. H. ASSUME THAT ALL EXISTING ELECTRICAL NOT SHOWN AS REMAINING ON THESE SHEETS IS TO BE DEMOLISHED. IF SOME EXISTING ITEMS NOT SHOWN ARE DEEMED TO BE NECESSARY FOR PROPER OPERATION OF THE FACIL I TY, VERIFY WI TH THE OWNER, ENGINEER, OR LANDLORD BEFORE PROCEEDING WITH DEMOLITION. EXERCISE CARE TO NOT DEMOLISH ANY ITEMS THAT ARE PART OF THE MALL '5 MEP SYSTEMS. I . THIS PROJECT UTILIZES A PLENUM RETURN A IR CEILING DESIGN. ALL EQUIPMENT AND MATERIALS INSTALLED IN THE PLENUM RETURN CEILINGS MUST MEET 77-1E FLAME SPREAD AND SMOKE DEVELOPED RATINGS OF 25/50 AND BE APPROVED FOR USE IN PLENUM RETURN CEILINGS. OFFICE AREA z L--13 LEGEND EXIST7NG NEW WORK NEW TO EX/S77NG CONNECTION 3 LIGHTING PLAN SCALE' 1/4' =1' -0' 1. LIGHTING CONTROL SW TCHBANK. SEE DETAIL 4/E -3 FOR ADDI TIONAL INFORMATION. LOWER CASE LETTERS SHOWN ON PLAN FROM LIGHTING CIRCUITS CORRESPOND TO SWITCHES ON DETAIL 4/E -3. CONTRACTOR SHALL VERIFY THAT SWI TCHBANK WILL FI T IN LOCATION INDI CA TED. IF NECESSARY, SW TCHBANK CAN BE STACKED TO CONSERVE SPACE. ELOT RECEIVED CITY OF TUKWILA NOV 1 3 7007 PERMIT CENTER d Schnack en 0 Newyork 0 Cmta a Losarlgele6 800 -581 -0963 wwwsdiriackelcom ELECTRICAL NOTES SCALD N.T.S. r 1E cic z 2 0 Sheet No. J J CD 2 It C W W CO =co �- Cnpa) W 0 uJ <- 0 L J W C/j W ea a ® '* WA cr 12 OD me g maw CI O ea c . z ar 0 ad Drawn By CBW Scale 1/4' =1' -0' E -2 Revisions a ISSUE TO LANDLORD 07 -06 -07 A REVISION PER LANDLORD 08-10-07 ,L REVISION PER LANDLORD 09 -10 -07 a ISSUE FOR PERMIT 09-10-07 , A REVISION PER CITY 11 -05 -07 DPIRES 12/21/07 ARCHITECT 1 MY QRIFY THAT 1NISE ME NAVE MEN FE- N= OUR NY WWI= NO 7x11T ID 1E NMI IF Hr 1010AJOIEE, 7IIE SNIE aBFLY WITH Pd . RULES, REGULATIONS MD IFOOINCES IF 4. WA RELATING TO STRUCTIXES AND BUILIINGS. Checked By SHE! Date 09 -10 -07 jm07 -9110 ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION 1 SYMBOL DESCRIPTION °TR CONTROL TRANSFORMER �3S CEILING MOUNTED SPEAKER TIVM EX WALL MOUNTED DUPL -20R RECEPTACLE - NEMA 5 RECESS WALL MOUNTED VOLUME CONTROL W31 V CABLE QUAN DESCRIPTION WALL PTACL MOUN TED QUADRUPLEX R RE - NEMA 5 - 20 A7OS LIGHTING AND APPLIANCE PANELBOARD RAN7030MH- X1- S -120V 1 CMH70PAR30 /FL25 SIGNALING SYSTEM PUSHBUTTON ® TELECOMMUNICATIONS SYSTEM BACKBOARD D X TRACK LIGHTING SIGNALING SYSTEM CHIME $ TOGGLE SWITCH I V SKECHERS oC CEILING MOUNTED DU n 1 RECEPTACLE - NEMA 5 -20R PLEX �7 3 T � GS- / 1=C ...© WALL MOUNTED JUNCTION BOX S, 0 CEILING MOUNTED DOWNLIGHT 4 WALL MOUNTED COMBINATION TELEPHONE /DATA OUTLT $ CEILING MOUNTED FLUORESCENT LUMINAIRE DOWNLIGHTS 457 0 CEILING MOUNTED JUNCTION BOX B7OW TRACK LIGHT • 1 L❑ DISCONNECT SWITCH. SEE PLAN FOR RATING. CTL7ODE-WW-P-LA-71-P CEILING MOUNTED FAN /LIGHT MI MH $F FUSED SWITCH t 0 CEILING MOUNTED DOWNLIGHT --E1 WALL MOUNTED TELEVISION OUTLET 1"420: CEILING MOUNTED DOWNLIGHT •■ SKECHERS HOMERUN TO PANEL. THE NUMBER OF ARROWS INDICATES THE NUMBER OF CIRCUITS. TWO WIRES UNLESS NOTED OTHERWISE. GROUND WIRE IS REQUIRED BUT NOT COUNTED IN HASH MARKS. LED STRIP LIGHT --- 0 STEM MOUNTED DOWNLIGHT ��,r CO NDUIT UP ... ��� �- . WALL MOUNTED 'BXI- SIGN_ R OVIDE �DIRE`f 1;10A!EAV- E S INI PZEFe NA es . ..- - - - - BRANCH CIRCUITING CONCEALED IN FLOOR( 8 ( 84 CEILING MOUNTED EXIT SIGN. PROVIDE DIRECTIONAL ARROWS AS INDICATED ON PLAN. 8" PL HSG 1/PLT32 120/277V SPECULAR MULTIPLIER TRIM (WHITE) EXPOSED BRANCH CIRCUITING �----.., BRANCH CIRCUITING CONCEALED IN WALLS OR CEILING RS8142VEMV- CST8422V -CLR 1 GX24Q -3, 4PIN GX24Q 3, 4PIN �� CONDUIT DOWN ELECTRICAL ABBREVIATIONS SYMBOL DESCRIPTION SYMBOL DESCRIPTION WP WEATHERPROOF NF NON -FUSED GFI GROUND -FAULT CIRCUIT INTERRUPT AFF ABOVE FINISHED FLOOR IG ISOLATED GROUND UNO UNLESS NOTED OTHERWISE TP TAMPERPROOF ST SHUNT -TRIP - HG HOSPITAL GRADE HACK AN ERR EFR GERA11ON) RATED ONING EM EMERGENCY NL NIGHTLIGHT LIGHTING FIXTURE SCHEDULE (NOTE 2) MARK MANUFACTURER CATALOG NUMBER LAMP INFORMATION (NOTE 1) VOLTS MOUNTING DESCRIPTION /REMARKS FURNISHED BY TIVM CEILING RECESS SURFACE W31 NIVHD CABLE QUAN DESCRIPTION TYPE A7OS CON -TECH RAN7030MH- X1- S -120V 1 CMH70PAR30 /FL25 MH 120 REF /MICROWAVE REC 4 X TRACK LIGHTING 900 20/1 C ACCENTUATE CONCEALED ADJUSTABLE ILLUMINA11ON (SILVER) SKECHERS A7OW CON -TECH RAN7030MH- X1- S -120V 1 2 CMH70PAR30 /FL25 70 WATT PAR30 LMH 120V MH MH 120 120 2091 Ake7eq,Aa X X $ 9 DOWNLIGHTS 457 ACCENTUATE CONCEALED ADJUSTABLE ILLUMINATION (WHITE) ACCENTUATE CONCEALED ADJUSTABLE ILLUMINATION (WHITE) SKECHERS SKECHERS B7OW CON -TECH RAN7030MH- X3- S -120V D170W CON -TECH CTL7ODE-WW-P-LA-71-P 1 CMH70 /TD /830 RX7S MH 120 500 X 12 13 SIO�WI DQ` 'LTG 1"420: 071 :20/1' STEALTH TRACK FIXTURE (WHITE) SKECHERS E32W CON-TECH RS8142VEMV- CTR8422V -WPF 1 PLT32 /SKYBRITE GX24Q -3, 4PIN CFL 120 B 10/1 X GEN. RECEPTACLES 16 17 TRACK LIGHTING 8" PL HSG 1/PLT32 120/277V SPECULAR MULTIPLIER TRIM (WHITE) SKECHERS E32S CON -TECH RS8142VEMV- CST8422V -CLR 1 GX24Q -3, 4PIN GX24Q 3, 4PIN CFL 120 5 kAIYA X 20/1 SPARE 20 8" PL HSG 1 /PLT32 120/277V SPECULAR MULTIPLIER TRIM (CLEAR) SKECHERS G70ALU DMF LIGHTING SIENA - LUME PENDANT COLLECTION - DP604 1 25W MIN - SPIRAL/ GX24Q -3 4PIN CFL 120 23 FLAT PANEL MONITOR 300 20/1 X 20/1 374 SUSPENDED PENDANT OVER CASH WRAP & MIRRORS SKECHERS H32 CRESCENT SC -232 -1 FLUOR STRIP LIGHT W/ SCG -4 WIRE GUARD (NOTE 3) 1 F32T8 /SKYBRITE -90 FL 120 LIGHT BOXES 26 27 SIGN 1200 X B 4' FLUORESCENT STRIP LIGHT, CHAIN HUNG @ +12' -6" A.F.F. MINIMUM SKECHERS K NUTONE VENT -A -LITE 668RP OR EQUIV. 1 100A /CL IND 120 20/1 X LIGHT BOXES 30 31 WH -1 2050 FAN /LIGHT SKECHERS S - -- - LED LED 120 - -- B - -- X 34 35 BLUE LED STRIP LIGHTS SKECHERS XG UTHONIA PRECISE EDGE-UT EXITS LRP 1 GC LA 120/277 EL N INC INDLUDED LED 120/277 X X 20/1 A 20/1 SPARE EXIT SIGN W/ BATTERY BACKUP, DIRECTIONAL INDICATORS AS NEEDED (GREEN) SKECHERS XE CON -TECH LIGHTING EL2HA5B 2 6V 5W DC T5 IND 120 X 41 SPACE X C EMERGENCY EGRESS FIXTURE SKECHERS PANEL L 120/208 VOLT, 3 PHASE, 4 WIRE 110 A. MAIN BKR. SURFACE MOUNTED toll SERVED w-r, . . C P '✓ B :,. `E�7'AD SERVEv� °14 NO. 1 TRACK LIGHTING 675 20/1 A ,20/1 500 WATER DISPENSER 2 3 TRACK LIGHTING 600 20/1 B 40/1 830 REF /MICROWAVE REC 4 5 TRACK LIGHTING 900 20/1 C 10/1 720 CASHWRAP REC 6 7 SALES FLOOR LIGHTING 840 20/1 A 2091 Ake7eq,Aa CASH -V -A. IRE $ 9 DOWNLIGHTS 457 20/1 B 20/1 360 SHOW WINDOW REC 10 11 AtatAIEEtsstlifriaPi ti ) C 20/1 500 KIDS SIGN 12 13 SIO�WI DQ` 'LTG 1"420: 071 :20/1' A °�2'0/ ?i X200 1 5 - 15 TRACK LIGHTING 900 20/1 B 10/1 540 GEN. RECEPTACLES 16 17 TRACK LIGHTING 1200 20/1 C 10/1 SPARE 18 "TA .: DESKPEPN 5 kAIYA tgAf 20/1 SPARE 20 21 DESK RECEPT 360 20/1 B 20/1 408 STOCKROOM UGHTING 22 23 FLAT PANEL MONITOR 300 20/1 C 20/1 374 STOCKROOM LIGHTING 24 25 LIGHTING CONTROLS 300 20/1 A 20/1 1800 LIGHT BOXES 26 27 SIGN 1200 20/1 B 20/1 360 TELEPHONE BOARD 28 29 SIGN 1200 20/1 C 20/1 1800 LIGHT BOXES 30 31 WH -1 2050 25/2 A 25/3 1674 VAV -1 32 33 2050 - -- B - -- 1674 34 35 SPARE 20/1 C - -- 1674 36 37 SPARE 20/1 A 20/1 SPARE 38 39 SPARE 20/1 B SPACE 40 41 SPACE C SPACE 42 LOADS BASED ON NATIONAL ELECTRIC CODE PANEL L CONNECTED LOAD BY PHASE TOTAL C,4 TOTAL W/ ES ell~lifi MorANfiqrtgeNegt :,. LIGHTING 1.25 3935 3565 6100 13600 17000 RNA Arek 1v7.601 1` 0 '192 :� : 1 9 ORS. 1 0 w OTHER 1 2350 2050 0 4400 4400 0 Q 0 0 KI- CHEN 1 NON - SIMULTAN 0 0 0 0 0 0 HEATING ONLY 1 1674 1674 1674 5022 5022 COOLING ONLY 0 0 0 0 0 0 EXIST. LOAD 1.25 0 0 0 0 0 - . ,�, , ... -sar -vp .,.., LOAD TOTAL - p- - 9719 <,, - .� 9739 - - 8794 - - �s. .. 28252 '. , a Alu 31652 LOW VOLTAGE CABLE 3/4 " EMT CONDUIT f+l BOX CONNECTOR WITH BUSHING WITHIN STOCK ROOM CEILING 4" SQUARE METAL BOX 1 -1/2" DEEP LOW VOLTAGE CABLE / SINGLE GANG PLASTER RING UNLESS OTHERWISE NOTED (TYPICAL PHONE OR DATA WALL ROUGH -IN DETAIL (a) L -24 (b) (c) L -22 L -9 (d) ® L -15 (e) L -17 (f) L -1 (g) (h) L -5 L -3 a -- 1/2 STOCKROOM LIGHTING (3 -WAY) b -- 1/2 STOCKROOM UGHTING (3 -WAY) c -- DOWNLIGHTING (SPST) d -- TRACK UGHTING (SPST) e -- TRACK LIGHTING (SPST) f -- TRACK LIGHTING (SPST) g -- TRACK LIGHTING (SPST) h -- TRACK LIGHTING (SPST) (0 L -7 (j) L -11 (k) ® ® L -13 L -7 i -- SALES FLOOR UGHTING (SPST) j -- LED LIGHTING (SPST) k -- SHOW WINDOW LIGHTING (SPST) I -- DAYLIGHTING AREA DOWNLIGHTING (SPST) m -- DAYLIGHIING AREA SALES FLOOR LIGHTING (SPST) n -- LIGHT BOXES (SPST) o -- LIGHT BOXES (SPST) (m) (n) (0) ® L -9 L -30 L -26 4 LIGHTING SWITCHBANK n NOTE 1: FL= FLUORESCENT, CFL = COMPACT FLUORESCENT, IND = INCANDESCENT, MH =METAL HALIDE, HPS =HIGH PRESSURE SODIUM, LPS =LOW PRESSURE SODIUM, MV= MERCURY VAPOR NOTE 2: FOR FIXTURES FURNISHED BY SKECHERS AND INSTALLED BY CONTRACTOR, CONTACT PREMIUM QUALITY LIGHTING, ATTN: ANDY SHREEDEN, (800) 323 -8107, WWW.PQLIGHIING.COM_ NOTE 3: PROVIDE MINIMUM 1100 LUMEN EMERGENCY BATTERY PACK IN FIXTURES MARKED "EM ". NOTE 4: LIGHT FIXTURES MARKED "NL" INDICATE A NIGHT LIGHT TO REMAIN ON DURING ALL HOURS. NOTE 5: INSTALLED BY G.G. AND WIRED BY E.C.,SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS AND QUANTITIES. NOTE 6: PROVIDE MINIMUM 950 LUMEN BATTERY ON COMPACT FLUORESCENT FIXTURES MARKED "EM ". 2 LIGHTING FIXTURE SCHEDULE n 9 - LOCKABLE BREAKER LEGEND EX /STING NEW WORK NEW TO EXIST /NG CONNECT /ON 9 5 PANEL SCHEDULE 6 3 ]ELECTRICAL SYMBOLS 480/277V, 3PH, 4W, 1200A PANEL 1D IN AREA 1D ELECTRICAL ROOM r J LOCATED WITHIN TENANT SPACE AND MAY BE UTILIZED FOR TEMPORARY POWER PANEL "L" 200A 3P CB 4 - #3/O, #6 GROUND IN 2 1/2" CONDUIT 200/3 � 200A FUSES 3 3 - #8, #10 GROUND IN 1" CONDUIT NEW TRANSFORMER 45KVA 3 PHASE, 480 VOLT DELTA PRIMARY, 120/208 VOLT WYE SECONDARY 4 - #2, #6 GROUND IN 1 1/2" CONDUIT £ LO7m s , lL1 RECEIVED CITY OF TUKWILA NOV 1 3 zuO7 PERMIT CENTER 6Sch 9 Newyork a Omaha A kel engineers. Los Angeles H 800- 581-0963 www.schnackel.com ONE -LINE DIAGRAM & NEC LEAD SUMMARY 0 a P am • tO • �Ne eig ® zx© • g as 0 2®i .® a " le ® � Drawn By CBV Scale NONE Revisions L ISSUE TO LANDLORD 07 -06 -07 Q REVISION PER LANDLORD 08 -10 -07 Q REVISION PER LANDLORD 09 -10 -07 L ISSUE FOR PERMIT 09 -10 -07 REVISION PER CITY 11 -05 -07 EXPIRES 12/21/07 ARCHITECT 1 IUE1T IERfST 11MT TEM PLANS R01Se T:ED(ME- MO MBER NY SIIPERVlSIIM APN VAT TEI T1E 113T IF KY MUM 11E ONLY dlI1N ALL MILES, FEELLATIONS IVO MUMS RELATING TO STRUCTURES MB BOLDING& Checked By SMO Date 09 -10 -07 Job07 -9110 Sheet No. E -3 ELECTRICAL SPECIFICATIONS NOTE! MANUFACTURER'S NAMES ON WHICH THIS SPECIFICATION IS BASED INDICATE THE MINIMUM QUALITY OF PRODUCT REQUIRED. SUBSTITUTION MAY BE MADE TO THOSE SPECIFIED IF DEEMED EQUIVALENT BY THE OWNER'S REPRESENTATIVE. A. THE GENERAL CONDITIONS AND SUPPLEMENTARY GENERAL CONDITIONS SHALL BE CONSIDERED AS PART OF THIS SPECIFICATION. B. ALL WORK TO BE IN ACCORDANCE WITH THE RULES AND REGULATION OF THE LOCAL AUTHORITIES HAVING JURISDICTION AND THE EDITION OF NATIONAL ELECTRIC CODE ADOPTED BY THAT JURISDICTION. C. THE CONTRACTOR SHALL FILE PLANS WITH AND OBTAIN APPROVALS FROM MUNICIPAL AGENCIES. ALL PERMITS AND CERTIFICATES OF INSPECTION SHALL BE OBTAINED AND PAID FOR BY THE CONTRACTOR. PERTINENT CERTIFICATES SHALL BE DELIVERED TO THE OWNER'S REPRESENTATIVE, PRIOR TO FINAL BILLING. D. THE CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS. HE SHALL CAREFULLY EXAMINE THE EXISTING CONDITIONS AND LIMITATIONS THEREOF. HE SHALL ASCERTAIN CONDITIONS UNDER WHICH THE WORK MUST BE PERFORMED, INCLUDING THE HANDLING OF MATERIALS, SECURITY AND LIMITING FIELD DIMENSIONS. FURTHER, THIS CONTRACTOR SHALL PROVIDE FIELD VERIFICATION OF LOCATION OF POINTS OF CONNECTION TO ELECTRICAL AND TELEPHONE SERVICE AND DISTANCE FROM BUILDING. ANY DISCREPANCIES WITH THE CONSTRUCTION DOCUMENTS DISCOVERED AS A RESULT OF THE AFOREMENTIONED FIELD SURVEY, SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE, PRIOR TO COMMENCING ANY WORK. ANY ADDITIONAL COSTS RESULTING FROM CONTRACTOR'S FAILURE TO DO SO SHALL BE HIS RESPONSIBILITY AND SHALL BE BORNE BY HIM. E. THE ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN HIS WORK AS THE JOB PROGRESSES; AN ACCURATE RECORD OF ALL WORK AS ACTUALLY INSTALLED. UPON COMPLETION OF THE WORK AND BEFORE FINAL PAYMENT IS AUTHORIZED, HE SHALL TURN OVER TO THE OWNER'S REPRESENTATIVE A RECORD SET OF PRINTS SHOWING THESE CHANGES. F. SUBMIT MATERIAL LISTS AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE OWNER'S REPRESENTATIVE FOR REVIEW. SUBMITTALS SHALL BE IN ACCORDANCE WITH GENERAL CONDITIONS AND SHALL BEAR THE STAMP OF THE ELECTRICAL CONTRACTOR SHOWING THAT HE HAS REVIEWED AND APPROVED THEM. LACK OF SUCH CONTRACTOR'S APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY THE OWNER. G. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING, OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK HEREIN, UNLESS OTHERWISE SPECIFIED. ANY CUTTING SHALL HAVE PRIOR APPROVAL BY THE OWNER'S REPRESENTATIVE. PROVIDE LISTED FIRESTOPPING AT ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, PARTITIONS, ETC. H. ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIR. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL, SUCH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE SECURED TO THE BUILDING STRUCTURE, NOT TO PIPING OR DUCTWORK. ALL CONDUIT SHALL BE CONCEALED WHERE POSSIBLE. EXPOSED CONDUIT SHALL BE RUN IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES AND SEPARATED AT LEAST 3" FROM WATER LINES WHEREVER THEY RUN ALONG SIDE OR ACROSS SUCH LINES. I. EVERY PART OF THE INSTALLATION SHALL BE TESTED, OPERATED AND LEFT IN PERFECT WORKING ORDER. TEST ALL WIRES AND CABLES INSTALLED UNDER THIS CONTRACT WITH A 1,000 VOLT MEGOHM METER. IF ANY READINGS ARE FOUND THAT ARE LOWER THAN REQUIRED BY GOOD PRACTICE OR APPLICABLE CODES, PROMPTLY REPLACE THE MATERIALS OR EQUIPMENT INVOLVED. SHOULD TESTING REVEAL ANY OTHER DEFECTS, PROMPTLY CORRECT SUCH DEFECTS AND RERUN TESTS UNTIL THE ENTIRE INSTALLATION IS SATISFACTORY IN ALL RESPECTS. J. GUARANTEE: 1. THE CONTRACTOR IS TO GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE PROJECT BY THE OWNER. IT IS UNDERSTOOD BY HIS ACCEPTANCE OF THE CONTRACT THAT THIS CONTRACTOR WILL MAKE GOOD ANY AND ALL WORK WHICH IN ANY WAY HAS BECOME DEFECTIVE AS TO THE QUALITY OF MATERIALS AND WORKMANSHIP FOR ANY CAUSE OTHER THAN ORDINARY WEAR AND TEAR. 2. FOR THE SAME PERIOD, THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND /OR INSTALLED BY HIM. K. BEFORE FINAL ACCEPTANCE BY THE OWNER WILL BE GRANTED, THE CONTRACTOR SHALL CLEAN ALL LIGHTING FIXTURES, DEVICE PLATES, SERVICE FITTINGS, AND OTHER ITEMS FURNISHED UNDER THIS CONTRACT. HE SHALL INSURE THAT ALL DIRECTORIES ARE IN PLACE WITH COMPLETED OR REVISED SCHEDULES AND ALL IDENTIFICATIONS AND MARKINGS OF EQUIPMENT, CABLES, AND OTHER ITEMS ARE COMPLETED. L. THIS CONTRACTOR SHALL COORDINATE SEQUENCE OF WORK WITH ALL OTHER TRADES. CONTRACTOR SHALL VERIFY VOLTAGE OF MECHANICAL EQUIPMENT AND FLUORESCENT FIXTURE BALLASTS PRIOR TO COMMENCING ANY WORK. NO REMOVALS SHALL BE MADE WITHOUT THE OWNER'S APPROVAL. ALL EXISTING EQUIPMENT, MATERIALS, ETC. THAT ARE NOT TO BE REUSED SHALL BE REMOVED COMPLETELY AND DISPOSED OF BY THIS CONTRACTOR. M. THIS CONTRACTOR SHALL MAKE ARRANGEMENTS FOR TEMPORARY POWER AND SHALL PAY THE COST FOR THE UTILITY CONNECTION AND SHALL BE RESPONSIBLE FOR THE PROPER MAINTENANCE OF THE TEMPORARY WORK AND FOR THE REMOVAL OF SAME. THE CONTRACTOR SHALL PAY ALL UTILITY CHARGES IN CONNECTION WITH THE TEMPORARY POWER. THE CONTRACTOR SHALL PROVIDE GROUND FAULT PROTECTION FOR ALL POWER EQUIPMENT USED ON THE PREMISES DURING CONSTRUCTION. N. SCOPE OF WORK: 1. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, SUPPLIES, EQUIPMENT AND FEES REQUIRED TO COMPLETELY INSTALL, TEST AND PLACE THE HEREIN SPECIFIED EQUIPMENT, COMPONENTS, CONTROLS, AND SYSTEMS IN SERVICE. 2- COMPLETE BRANCH CIRCUIT WIRING SYSTEM. 3- COMPLETE UTILITY MOTOR WIRING SYSTEMS, (EXCEPT AS NOTED) FOR ALL AIR CONDITIONING AND /OR HEATING EQUIPMENT, EXHAUST EQUIPMENT AND CONTROLS. 4. COMPLETE LIGHTING FIXTURE INSTALLATION. 5. COMPLETE TELEPHONE AND DATA ROUGH IN AND CABLING. 6. TEMPORARY ELECTRICAL SERVICE AS REQUIRED FOR CONSTRUCTION. 7. POWER TO ALL SIGNS AND GRAPHICS, FURNISHED BY THE OWNER. 8. TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION. 9. TESTING OF ALL ELECTRICAL EQUIPMENT. 10. WARRANTY OF ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF PROJECT CLOSE -OUT. 11. ALL NEW FIRE ALARM COMPONENTS AS SHOWN. 0. ELECTRICAL SERVICE IS NEW: P. PHONE AND DATA WIRING: 1. CONTRACTOR SHALL PROVIDE A PLYWOOD BACKBOARD AS INDICATED ON THE DRAWINGS WITH AN EQUIPMENT GROUNDING BAR CONNECTED TO THE POWER PANEL GROUND BUS WITH A MINIMUM #6 AWG COPPER CONDUCTOR. THIS BACKBOARD IS TO BE PAINTED BY THE CONTRACTOR WITH A FIRE RETARDANT PAINT. 2. THE CONTRACTOR SHALL PROVIDE ROUGH IN LOCATIONS AS INDICATED ON THE DRAWINGS AND AS DETAILED THEREIN. THE CONTRACTOR SHALL PROVIDE (2) PLENUM RATED CATAGORY 5 CABLES TO EACH LOCATION INDICATED ON THE DRAWINGS. ALL CABLE SHALL EXTEND TO THE PHONE BOARD WITH ENOUGH SLACK TO EXTEND 24" BEYOND THE BOTTOM OF THE BOARD AND 12" FROM THE FACE OF EACH JACK LOCATION. ALL CABLES ARE TO BE TAGGED AT BOTH ENDS. Q. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. R. THE WORD "PROVIDE" AS USED HEREIN MEANS TO FURNISH AND INSTALL COMPLETE. 2. MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING COMPONENTS THEREOF, SHALL BE NEW AND SUCH AS APPEARS ON THE UNDERWRITER'S LABORATORY LIST OF APPROVED ITEMS AND SHALL MEET THE REQUIREMENTS OF RECOGNIZED STANDARDS. 3. EQUIPMENT SHALL BE SIZED IN CONFORMITY WITH REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AND OTHER APPLICABLE CODES. 1. CONDUIT SHALL BE STANDARD STEEL, RIGID, IMC, OR EMT (THIN WALL) ACCORDING TO CODE REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FINISHED AREAS EXCEPT AS OTHERWISE APPROVED BY THE OWNER'S REPRESENTATIVE. EMT CONNECTIONS SHALL BE EITHER SET SCREW OR COMPRESSION TYPE. MINIMUM SIZE OF CONDUIT SHALL BE 1/2". EMT SHALL BE GALVANIZED OR ELECTRO- GALVANIZED. EMT SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS RUN ABOVE SUSPENDED CEILINGS OR CONCEALED IN INTERIOR PARTITIONS. EMT SHALL NOT BE CONCEALED IN POURED CONCRETE FLOOR OR WALLS. 2. USE HEAVY WALL CONDUIT OR IMC FOR UNDER SLAB INSTALLATIONS. IMC IS PERMITTED WITH THREADED CONNECTIONS. 3- FLEXIBLE METAL CONDUIT MAY BE USED ONLY FOR SHORT (6' MAX.) CONNECTIONS TO FIXTURES AND EQUIPMENT AS PERMITTED BY CODE OR WHERE INDICATED ON THE DRAWINGS. 4. PROVIDE PLASTIC BUSHINGS AT OPEN ENDS OF ALL CONDUITS WITH LOW VOLTAGE WIRING. PROVIDE PULL WIRE IN ALL CONDUIT FOR LOW VOLTAGE WIRING. S. RACEWAYS SHALL BE SURFACE METAL TYPE OF THE SIZE AND CHANNEL REQUIRED FOR SERVICE, CONSTRUCTED OF GALVANIZED STEEL WITH SNAP -ON COVERS, WITH 1/8" MOUNTING SCREW KNOCKOUTS IN BASE APPROXIMATELY 8" 0.C. PROVIDE FITTINGS INDICATED WHICH MATCH AND MATE WITH RACEWAY. FINISH WITH MANUFACTURER'S STANDARD PRIME COATING SUITABLE FOR PAINTING. T. ALL CONDUCTORS SHALL BE SOFT DRAWN, ANNEALED COPPER, WITH 600V INSULATION: 1- 1. #10 AND SMALLER - SOLID. #8 AND LARGER - STRANDED. MINIMUM WIRE SIZE SHALL BE #12, EXCEPT #14 MAY BE USED FOR CONTROL APPLICATIONS. 2. ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. 3. GENERAL WIRING SHALL HAVE THHN OR THWN INSULATION. 4. ALUMINUM CONDUCTORS ARE NOT PERMITTED. 5. WIRE CONNECTORS SHALL BE EQUAL TO SCOTCHLOCK FOR #8 AND SMALLER, AND T & B "LOCK -TITE" FOR #6 AND LARGER. 6. WIRES SHALL BE COLOR CODED PER NEC. U. OUTLET BOXES AND COVERS SHALL BE ONE PIECE, GALVANIZED OR SHERARDIZED STEEL; 4 "x4", KNOCK -OUT TYPE WITH FIXTURE STUDS AS REQUIRED. JUNCTION BOXES, PULL BOXES AND COVERS SHALL BE GALVANIZED STEEL, CODE GAUGE AND SIZE. V. WIRING DEVICES: 1. WALL SWITCHES, SINGLE POLE, DOUBLE POLE, AND THREE WAY SHALL BE GENERAL DUTY, FLUSH, TOGGLE SWITCHES; SPECIFICATION GRADE 20A, 120 /277V, WITH SCREW TERMINALS. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR, OR LEVITON. 2. GENERAL DUTY DUPLEX RECEPTACLES SHALL BE 2 -POLE, 3 -WIRE GROUNDING TYPE, SPECIFICATION GRADE, 20A, 125V, NEMA 5 -20R UNLESS OTHERWISE INDICATED, MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR, OR LEVITON. A) GENERAL DUTY FLOOR MOUNTED RECEPTACLES SHALL BE 2 -POLE, 3 -WIRE GROUNDING TYPE, SPECIFICATION GRADE, 20A, 125V, NEMA 5 -20R UNLESS OTHERWISE INDICATED, MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR, OR LEVITON. 3. GROUND FAULT INTERRUPTER RECEPTACLE SHALL BE GENERAL DUTY, DUPLEX RECEPTACLES, GROUND FAULT CIRCUIT INTERRUPTER, FEED THROUGH TYPE, CAPABLE OF PROTECTING CONNECTED DOWNSTREAM RECEPTACLES ON A SINGLE CIRCUIT, GROUNDING TYPE UL -RATED CLASS A, GROUP 1, 20A, 120V, 60 HZ; WITH SOLID -STATE GROUND FAULT SENSING AND SIGNALING; WITH 5 MILLIAMPERES GROUND FAULT TRIP LEVEL; IN NEMA 5 -20R CONFIGURATION. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR, OR LEVITON. 4. DUPLEX ISOLATED GROUND TYPE RECEPTACLE SHALL BE 2 -POLE, 4 -WIRE, 20A STRAIGHT BLADE DEVICE WITH SEPARATE ISOLATED GROUND AND BUILDING GROUND CONNECTIONS, IN NEMA 5 -20R CONFIGURATION AS MANUFACTURED BY HUBBELL IG -5362. 5. DATA OUTLET DEVICES AS SHOWN ON THE DRAWINGS. 6. WIRING DEVICE ACCESSORIES INCLUDING ALL WALL PLATES SHALL BE PROVIDED AT EACH DEVICE. WALL PLATES SHALL BE STAINLESS STEEL. MOUNTING HEIGHTS OF DEVICES SHALL BE TO THE FOLLOWING CENTERLINES: A) TOGGLE SWITCHES 46" RECEPTACLES 16" WALL TELEPHONE OUTLETS 54" DISCONNECT SWITCHES 5' -6" PANEL BOARDS 6' -0" TO TOP W. THIS CONTRACTOR SHALL PROVIDE A COMPLETE SYSTEM OF GROUNDING FOR ALL EQUIPMENT AND STRUCTURES. A GOOD MECHANICAL AND ELECTRICAL CONNECTION SHALL BE MADE WITH APPROVED GROUNDING CONNECTORS. ELECTRICAL SYSTEM AND EQUIPMENT GROUNDS SHALL COMPLY WITH ALL LOCAL, STATE AND NEC CODES AND REGULATIONS. PANELS, CONDUIT SYSTEMS, MOTOR FRAMES, LIGHTING FIXTURES, AND OTHER EQUIPMENT THAT ARE A PART OF THIS INSTALLATION SHALL BE SECURELY GROUNDED BOTH MECHANICALLY AND ELECTRICALLY IN ACCORDANCE WITH ALL CODES. MAIN GROUNDING SYSTEM SHALL BE SIZED TO CONFORM WITH THE CURRENT LOCALLY ENFORCED EDITION OF THE NATIONAL ELECTRICAL CODE. PROVIDE CONDUIT TO PROTECT GROUND WIRE FROM DAMAGE TO AN AREA 6 FT. ABOVE FLOOR. MAKE ALL JOINTS AND CONNECTIONS OF THE CONDUIT SYSTEM TIGHT TO MAINTAIN CONTINUITY OF MECHANICAL AND ELECTRICAL GROUND THROUGHOUT ENTIRE SYSTEM. GROUND ALL 3 WIRE RECEPTACLES TO THE OUTLET BOXES. GROUND CONDUCTOR SHALL BE PROVIDED IN ALL CONDUITS. X. UGHTING PANEL BOARD IS NEW. ALL NEW BREAKERS PROVIDED UNDER THIS CONTRACT SHALL EXCEED THE AVAILABLE FAULT CURRENT. PANELBOARD SHALL BE SQUARE 'D' TYPE NQOD, OR EQUAL, WITH COPPER BUSSING. CIRCUIT BREAKERS SHALL BE BOLT -ON TYPE. MULTI -POLE CIRCUIT BREAKERS SHALL BE PROVIDED WITH A COMMON TRIP HANDLE- UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL PROVIDE A TYPED PANELBOARD CIRCUIT DIRECTORY IN A PLASTIC SLEEVE ON THE INSIDE OF THE PANELBOARD DOOR. Z. Y. PROVIDE SAFETY AND DISCONNECT SWITCHES, FUSED OR NON- FUSED, AS CALLED FOR ON DRAWING AND AS REQUIRED BY CODE. SWITCHES SHALL BE HEAVY DUTY, LOAD AND HORSEPOWER RATED AS MANUFACTURED BY SQUARE -D, GENERAL ELECTRIC, OR EQUAL. SWITCH ENCLOSURE TO BE SUITABLE FOR APPLICATION. FUSES SHALL BE BUSSMANN "LOW PEAK" DUAL ELEMENT CURRENT LIMITING FUSES OR AS NOTED ON DRAWINGS. SIGN(S) AND GRAPHIC(S) INCLUDING HIGH VOLTAGE TRANSFORMERS, IF REQUIRED, ARE PROVIDED BY SIGN CONTRACTOR. AA. HEATING AND COOLING MOTORS AND CONTROLS 1- ALL LINE AND LOW VOLTAGE POWER AND CONTROL WIRING INCLUDING TEMPERATURE CONTROL WIRING, CONNECTION TO MOTORS, DAMPERS, INSTALLATION OF THERMOSTATS, INTERLOCKING, ETC. EXCEPT AS SPECIFICALLY NOTED AS BEING BY MECHANICAL CONTRACTOR, SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 2. PROVIDE DISCONNECT SWITCHES (EXCEPT WHERE SPECIFICALLY SPECIFIED BY OTHERS) AND RUN MOTOR CIRCUITS FROM THE POWER PANEL THROUGH DISCONNECT SWITCHES AND STARTERS TO MOTOR TERMINALS. MAKE ALL POWER LINE VOLTAGE CONNECTIONS COMPLETE AS REQUIRED. 3. STARTERS AND DISCONNECTS SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. ELECTRICAL CONTRACTOR SHALL CONNECT ALL MOTORS FURNISHD BY THE MECHANICAL CONTRACTOR WHICH DO NOT COME FACTORY WIRED IN THE EQUIPMENT. 4. THE ABOVE ELECTRICAL EQUIPMENT SHALL BE MOUNTED SECURELY TO THE WALLS OR FRAMES AND THE ELECTRICAL CONTRACTOR SHALL FURNISH ALL NECESSARY BRACKETS, AUXILIARY STEEL, EXPANSION BOLTS AND OTHER ACCESSORIES REQUIRED. 5. WOODEN PLUGS SHALL NOT BE PERMITTED FOR ANCHORING. 6. THE MECHANICAL CONTRACTOR SHALL FURNISH ALL CONTROL DEVICES AND WIRING DIAGRAMS TO THE ELECTRICAL CONTRACTOR FOR INSTALLATION BY HIM. 7. ELECTRICAL CONTRACTOR SHALL PERMANENTLY LABEL ALL DISCONNECT SWITCHES, CONTACTORS, CONTROLS AND BOXES IN THE SYSTEMS. IDENTIFY EACH AS TO USE, ON THE FACE OF CABINETS OR COVERS BY MEANS OF A LAMINATED BLACK AND WHITE PHENOLIC LABEL. 8. PROVIDE 2 "x4" RECTANGULAR J ---BOX FOR THERMOSTAT MOUNTED HORIZONTALLY AT 48" A.F.F. EXTEND CONDUIT CONCEALED IN WALL TO ABOVE CEILING. BB. LIGHTING FIXTURES: 1. UGHTING FIXTURES ARE FURNISHED BY SKECHERS AND INSTALLED AND WIRED BY THE ELECTRICAL CONTRACTOR. ALL FIXTURES SHALL BE HUNG, MOUNTED IN PLACE, LAMPED, PROPERLY WIRED, TESTED, AND LEFT READY FOR OPERATION. EMERGENCY AND EXIT LIGHTS SHALL BE CIRCUITED WITH AN UNSWITCHED CONDUCTOR. CC. PAINTING OF ELECTRICAL CONDUITS, ETC. IF REQUIRED, WILL BE BY THE GENERAL CONTRACTOR. DD. PROVIDE SEISMIC RESTRAINTS FOR ALL ELECTRICAL EQUIPMENT AND ALL CONDUIT 2-1/2" AND LARGER. PER APPLICABLE SEISMIC ZONE. EE. FIRE ALARM SYSTEM: 1. CONTRACTOR SHALL PROVIDE FIRE ALARM COMPONENTS COMPATIBLE WITH THE LANDLORD'S SYSTEM AND INCLUDE ALL ASSOCIATED COSTS IN THE BID. THE INSTALLED SYSTEM SHALL COMPLY WITH NFPA 72, 101, AND THE ADA GUIDELINES. EXISTING FIRE ALARM COMPONENTS MAY BE REUSED IF THEY MATCH ANY NEW DEVICES IN PHYSICAL APPEARANCE. CONNECT ALL NEW COMPONENTS TO THE EXISTING SYSTEM AND PROVIDE FOR AN ACCEPTANCE TEST FOLLOWING SUBSTANTIAL COMPLETION OF THE PROJECT. 2. SMOKE DETECTORS SHALL BE MOUNTED AT THE TOP OF TH STRUCTURAL CEILING. CONTRACTOR SHOULD TAKE STRATIFI INTO ACCOUNT WHEN PLACING THE DETECTORS. FF. FINALLY: REVIEVWED FO C E COMPLIANCE E NFPA 7 DEC 1 1 2001 1. IT IS THE INTENT THAT THE FOREGOING WORK SHALL BE COM LETE IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT INSTALLED WITHOUT ADDITIONAL COST. Of Tukwila SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT City NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNIS 2. THE LOCATION OF RECEPTACLES AND FIXTURES SHOWN ON TH DRAWING IS APPROXIMATE AND THE OWNER SHALL HAVE THE RIGHT TO RELOCATE ANY RECEPTACLES OR FIXTURES BEFORE THEY ARE NOTES: 1. THIS NO BX, AC, MC OR ROMEX TYPE WIRING ALLOWED. 2. NO ATTACHMENT OR SUPPORT FROM ANY ROOF DECK IS ALLOWED. HANGERS, CLAMPS AND SUPPORTS SHALL BE FASTENED TO BAR JOISTS OR BEAMS ONLY. 3. TENANT'S ELECTRICAL CONTRACTOR SHALL FURNISH AN IDENTIFICATION NAMEPLATE ON TENANT'S MAIN DISCONNECT SWITCH IN LANDLORD'S SWITCHBOARD. NAMEPLATES SHALL BE ONE - EIGHTH INCH (1/8") THICK PLASTIC, BLACK ON WHITE AND ETCHED LETTERS. THE MINIMUM SIZE SHALL BE ONE INCH (1") WITH ONLY THE TENANT'S SPACE NUMBER ENGRAVED ON SUCH, PERMANENTLY AFFIXED. 4. LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO LANDLORD'S FIRE ALARM SYSTEM AT THE TENANT'S SOLE COST AND EXPENSE. 5. TENANT SHALL INSTALL WITHIN TENANT'S PREMISES A FIRE ALARM SYSTEM OR COMPONENTS AS DELINEATED THROUGH DESIGN DOCUMENTS ISSUED BY LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR (AT TENANT'S EXPENSE). DRAWINGS SHALL COMPLY WITH ALL ASPECTS OF THE TENANT CRITERIA MANUAL - FIRE ALARM SYSTEM - TENANT WORK AND DRAWING REQUIREMENTS. A COPY OF FIRE ALARM DRAWINGS SHALL BE ISSUED TO THE LOCAL FIRE MARSHAL'S OFFICE. ELO7 siy -J -J CD 2 c s C!� = oD co C0 8 I MI I uJ W CO z LJ- LLI CL LLI L LI ILDIN ..D :. SION EiSch RECEIVED CCTV OF TUKWILA NOV 1 3 2007 pFMIT CENTER NewYark a engineers., Omaha ® LmsAngeles a 800-581-0963 www.schnadceLcom Pm 42 qa 0' e CA 5 2 46 Co B C9 0 U 2 C 411 gal fig. :Z 'c .- KO V Revisions ISSUE TO LANDLORD 07-06-07 L REVISION PER LANDLORD 08 -10 -07 aL REVISION PER LANDLORD 09 -10 -07 A ISSUE FEIR PERMIT 09 -10 -07 REVISION PER CITY 11 -05 -07 EXPIRES 12/21/07 ARCIIYTECT I IEIEDY CERTIFY THAT TI&"SE PLANS HAVE MEN KE- PARED OMR NY SLF RVISMN NO TRIIT TO THE OW IF NY IOIIIdLBE, TIE SAVE CQMLY VIIH ALL RILES, RE6LLATII]HS AND CRIONMEES IF IIRWILLYA RELATING TO STRUL1V ES AND 1U.DINGS, Drawn By CBw Scale NONE Sheet No E -4 Checked By SMD Date 09-10-07 X07 -9110