Permit EL07-557 - WESTFIELD DEVELOPMENT
WES I 1 HELD DEVELOPMENT 235 STRANDER BL ELO7-557 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Signature: Print Name: doc: EL -4/07 Name: Address: Contact Person: Name: Address: Contractor: Name: Address: 2623049102 235 STRANDER BL TUKW WESTFIELD DEVELOPMENT 235 STRANDER BL , TUKWILA WA A 4 LLC 117 E LOUISA ST #230 , SEATTLE WA SANDY SHERMAN P O BOX 1489 , SNOHOMISH WA SERVICE ELECTRIC CO INC P O BOX 1489 , SNOHOMISH WA Contractor License No: SERVIEC564RU DESCRIPTION OF WORK: NEW TRAFFIC SIGNAL SERVICE AND CONTROL Value of Electrical: Permit Center Authorized Signature: City-rd Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us $6,500.00 Fees Collected: '`r 5A-/e7 ELECTRICAL PERMIT EL07 -557 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 360 -568 -6966 Phone: 360 -568 -6966 Expiration Date: 07/31/2009 Type of Fire Protection: National Electrical Code Edition: Electrical Service provided by: PUGET SOUND ENERGY EL07 -557 10/11/2007 04/08/2008 Date: $246.00 2005 I hereby certify that I have read and ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied whether specified herein or not. The granting of this emit does not presum to give authority to violate or cancel the provisions of any other state or local laws regulating construction or th p rformance o work. I orized to sign and obtain this electrical permit. Date: 6//7/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 10 -11 -2007 Parcel No.: 2623049102 Address: 235 STRANDER BL TUKW Suite No: Tenant: 1: ** *ELECTRICAL * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us WESTFIELD DEVELOPMENT PERMIT CONDITIONS 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating cons on or the performance of work. Signature: / � � ,< Date: /b7/1/ Print Name: doc: Cond -Elec Permit Number: Status: Applied Date: Issue Date: ELO7 -557 ISSUED 10/01/2007 10/11/2007 EL07 -557 Printed: 10 -11 -2007 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www. ci. tkwila. wa. us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print** Site Address: 235 NC \u Tenant Name: £4s+ i C' Pt�IOPVUQ(4 Property Owners Name: " 1 - S 1 Mailing Address: z 3 S S- K- id Name: 44:56 or Sc &d. / S 1 4 TVA t v\ Mailing Address: PO 14'4 Company Name: Se - u e E(ec k. Co TAX_ H:Mpplicaaonfforms- Applications On Line\4 -2007 - Electrical Permit Applicaaon.doc bh King Co Assessor's Tax No.: 2-10 l t D 1' Suite Number: City State Floor: New Tenant: ❑ Yes ❑..No Zip CONTACT PERSON Wha we contact when your permit ready to be issue' Day Telephone: r '5Zog (o46G t City State Zip E -Mail Address: Fax Number: ELECTRICAL CONTRACTOR INFORMATION Sl„S City Mailing Address: / PO t QDX L4 I Contact Person: 4e c4 y/ 3—C..)1/0k1 � E -Mail Address: Contractor Registration Number: Expiration Date: State Zip Day Telephone: 4 zs 508 4414E7 Fax Number: Valuation of Project (contractor's bid price): $ b, Scope of Work (please provide detailed information): TRa.- r ( Ee-fvl' .p acl Will service be altered? gi Yes ❑ No Adding more than 50 amps? Yes ❑ No Type of Use: Type of work: New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: Puget Sound Energy ❑ Seattle City Light Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) $140.00 575.00 ea $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration 575.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change 550.00 (up to 5 circuits) ❑ Circuits added/altered without service change 550.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ECT :i (ti CONTRACTOR: i / Signature: /•/ �!� Print Nam ! i�L�I+J A L' Mailing Address: DO Eo)c /4 I Date Application Accepted: (D - I-07 H: Appiications\Fomss- Applications On Line44-2007 - Electrical Permit Application.doc bh Date: JO —1 — C)') Day Telephone: 4ZS City State Zip Date Application Expires: 9_ L S Staff Initials: Lije Page 2 of 2 Parcel No.: 2623049102 Address: 235 STRANDER BL TUKW Suite No: Applicant: WESTFIELD DEVELOPMENT Receipt No.: R07 - 02218 Initials: JEM User ID: 1165 Payee: SERVICE ELECTRIC CO., INC. ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 63397 46.00 Account Code Current Pmts 000.345.832.00.0 46.00 Total: $46.00 Permit Number: EL07 -557 Status: APPROVED Applied Date: 10/01/2007 Issue Date: Payment Amount: $46.00 Payment Date: 10/11/2007 12:25 PM Balance: $0.00 doc: Receiot -06 Printed: 10 -11 -2007 Parcel No.: 2623049102 Address: 235 STRANDER BL TUKW Suite No: Applicant: WESTFIELD DEVELOPMENT Payee: ANDY JOHNSON ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Receipt No.: R07 -02131 Payment Amount: $200.00 Initials: WER Payment Date: 10/01/2007 12:12 PM User ID: 1655 s Balance: $46.00 TRANSACTION LIST: Type Method Description Amount Payment Cash 200.00 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 ELECTRICAL PLAN - NONRES 000 .345.832.00.0 Permit Number: EL07 - 557 Status: PENDING Applied Date: 10/01/2007 Issue Date: 196.80 3.20 Total: $200.00 3f,67 IVO! ?710 frawf- TOJ 2 00 doc: Receipt -06 Printed: 10 -01 -2007 Project: WESTf /F L- A Ai ! Type of Inspection: ...!2/e/-0 ( I U Address: � ^ 9.il .� 7 7 .5al Date Called: t Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: INSPECTION NO. PERMIT NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 0 OMMENTS: r/z '•proved per applicable codes. ❑ Corrections required prior to approval. Inspect Date: pit G Ef /,(X// X0 %7 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: r Project: kl,crcif t-A Type of Inspection_,. 2..... Address: 2 5 P I M W A / V() Date Called: Special Instructions: Date Wanted: / Gun- Requester: Phone No: it-07-3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 4'- 63 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 .Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 0/4- SF-A 1//6F inspectoP7 Date: / Q.$11/ 6a7 I / 0 //S7G 7 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: • 2RVICE ADDRESS $Co I b 51-ret ^ y- BAIA TYPE OF SERVICE DESIRED ❑ Temporary Overhead ❑ Temporary Underground EXISTING DISTRIBUTION TYPE Overhead ❑ Underground SE • NDARY VOLTAGE REQUIRED 1201240 ■ 1201208 GENERATORS ELLGTRICAL LOA IN ..PANEL SIZES (A MMPS) AND No! loft • OF METERS PER PANEL PHASE REQUIRED Single Phase ❑ Three Phase lore you instal YES Generator output (KW. MwL� w0 this generator operate full tons? ❑ YES ❑ NO Wilt this generator operate In parallel with PSE's distribution system? ❑ YES ❑ NO MOVING EXISTING FACILITIES wia existing power facilities require relocation? (Mark on site plan) ❑ YES ❑ NO DESCRIBE writ street lets be required? ❑ YES Bitling • en DATES SERVICE NEEDED MOTOR DETAILS Construction Start Date Date Temporary Service Required Date Permanent Service Required SPECIAL INSTRUCTIONS 1370 05/07 bade or emergency generation? � T Vkr.+.>ilr N ❑ Permanent Overhead .. Underground BUILDING TYPE & USE TOTAL SQUARE FOOTAGE 277 1480 OCT 1.0 2007 City Of Tukwila R ILnTNr UNDERGROUND SECONDARY CONDUCTOR SIZE Ughtf Heating Cooking Refrigeration Elevators Other Motors Water Heating Cooking Existing Load Total Conn Load Est. Total Demand 1 FOR CODE COMPLIANCE NFPA 70 NEC - I OWNER 1 PHASE Miscellaneous 6.0 On GSbz> OPERATING HOURS PER WEEK IL) T PHASE PHASE PHASE NUMBER WIRES PER RUN NEUTRAL SIZE NO, OF RUNS 3 PHASE PANEL SIZES Main Panel Size Am DAYS PER WEEK NEMA CODE NEMA CODE NEMA CODE LRC LRC RECEIVED CITY OF TUKWILA OCT 0 9 2007 PERMIT CENTER NO. METERS t ail ihn that the above Infommation correc • the best of my knowledge, and that 1 have been provided with a construction information sheet 1 understand that any changes 1 make In the above information or drawings will increase the time required for Puget Sound Energy to provide service to my project and that 1 might be liable for additional rr� ineering and construction costs, SIGNATURE OF OWNER/REPRESENTATIVE PRINT NAME DATE Pace 20(2 FILE COPY TROMPi ETE fair4 _ SS1 - Type Secondary Voltage kVA R/X Minimum %Z 3 Phase &/or L-G Fault Current 3 -Phase PM 208Y/120 45 0.8 1.65 7600 112.5 0.3 1.65 19000 150 0.3 1.55 26900 225 0.2 2.15 29100 300 0.3 2.10 39700 500 0.2 2.30 60300 750 0.1 5.32 39100 1000 0.1 5.32 52200 480Y/277 45 0.8 1.65 3300 112.5 0.3 1.65 8200 150 0.3 1.55 11600 225 0.2 2.15 12600 300 0.3 2.10 17200 500 0.2 2.30 26200 750 0.1 5.32 17000 1000 0.1 5.32 22600 1500 0.1 5.32 33900 2000 0.1 5.32 45200 2500 0.1 5.32 56500 Type Secondary Voltage kVA R/X 120V Winding 240V Winding Min %Z Fault Current Min %Z Fault Current 1 -Phase PM 240/120 25 0.8 2.23 9300 1.7 6100 37.5 0.7 2.23 14000 1.7 9200 50 0.6 2.23 18700 1.7 12300 75 0.5 2.34 26700 1.8 17400 100 0.5 2.30 36200 1.8 23100 167 0.5 2.43 57300 1.9 36600 Fault current levels UNDERGROUND SERVICES 25 The maximum available short- circuit current at the transformer's secondary connection point for most commonly used padmounted transformers installed by PSE, are shown in Tables 3, 4 and S. For additional transformer types and sizes contact your CCS Representative. NOTE: Always use the next larger size transformer to allow for future system expansion or upgrade. Table 3 Maximum short circuit current (in amps) for single -phase transformers, padmounted Table 4 Maximum short circuit current (in amps) for three -phase transformers, padmounted ELECTRIC SERVICE HANDBOOK / COMMERCIAL /INDUSTRIAL/MULTIFAMILY DEVELOPMENTS CHAPTER 3 Strander Blvd Traffic Signal Service Electric Co., Inc. Available Fault Current Calculation Utility Fault Current I = kVA x 1000 = trans. FLA E Isca = trans. FLA x 100 transformer Z Isca = ampere short- circuit current RMS symmetrical. Point to Point Method 'f ' factor = Multiplier M= 1 1+f 23,132) Line to Line Line to Neutral Fault Current at Service Equipment amperes kVA = E = trans. FLA = FEET Length (distance) 2xLxI (ASC) N x C x E L -N # conductors per phase Phase conductor constant Volt Line to Line Neutral conductor constant Volt Line to Neutral Isca x M = fault current at terminals of main disconnect L- L = Isca x M = fault current at terminals of main disconnect L- N = Isca = Isca = N C L - L = f = C = EL - N = f = M = M = 25 240 104 104 2.231 4,671 651 23,132 2.073 6,0441 120 4.146 0.325 0.194 amperes Single Phase 240/120 V' Copper in Nonmetallic Raceway Phase Conductor Volt Neutral Conductor Volt 7,527 amperes 6,743 amperes by:John sokolik Ver. 6.3 raplids©earthlink.net 2 2 V" October 3, 2007 Sandy Sherman P O Box 1489 Snohomish, WA 98291 RE: Letter of Incomplete Application # 1 Electrical Permit Application EL07 -557 Westfield Development — 235 Strander Bl Dear Ms. Sherman: This letter is to inform you that your permit application received at the City of Tukwila Permit Center on October 1, 2007 is determined to be incomplete. Before your application can continue the plan review process the following item from the following department needs to be addressed: Building Department: Bill Buterbaugh, at 206 973 -4758, if you have any questions concerning the following comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that three (3) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, , �J 5Z Bill Rambo Permit Technician Enclosures File: EL07 -557 City of Tukwila 1. Provide complete load calculations. 2. Provide fault current calculations. Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director P:\Permit Center\Incomplete Letters\2007\EL07- 557 incomplete Ur #1.DOC wer 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DEPARTMENTS: Io - o a Buil CI : Division Public Works Complete Comments: Documents/routing slip.doc 2 -28-02 APPROVALS OR CORRECTIONS: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL07 -557 DATE: 10 -09 -07 PROJECT NAME: WESTFIELD DEVELOPMENT SITE ADDRESS: 235 STRANDER BL Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ Planning Division ❑ Permit Coordinator ❑ DUE DATE: 10-11 -07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 11-08-07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPARTMENTS: Btitilding { B i I�n Public Works ❑ Documents/routing slip.doc 2 -28-02 COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL07 -557 DATE: 10 -01 -07 PROJECT NAME: WESTFIELD DEVELOPMENT SITE ADDRESS: 235 STRANDER BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued 0d2�1 APPROVALS OR CORRECTIONS: Fire Prevention n Planning Division Structural DETERMINATION OF COMPLETENESS: (Tues., Thu s.) Complete ❑ Incomplete ❑ Permit Coordinator DUE DATE: 10 -02 -07 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: 10 - 3-U7 Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 10 -30 -07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Project Name: Westfield Development Project Address: 235 Strander Bl Contact Person: Sandy Sherman Received at the City of Tukwila Permit Center by( Entered in Permits Plus on 101, 0 11 4 0 ' la pplications\fonms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Plan Check/Permit Number: EL07 -557 Steven M. Mullet, Mayor Steve Lancaster, Director ® Response to Incomplete Letter # 1 RECEIVED CITY O F TuKwIL q ❑ Response to Correction Letter # OCT 0 9 2007 ❑ Revision # after Permit is Issued PERMIT CENTER ❑ Revision requested by a City Building Inspector or Plans Examiner Phone Number: %O 5 IP E (Ail to Summary of Revision: Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision License Information License SERVIEC564RU Licensee Name SERVICE ELECTRIC CO INC Licensee Type ELECTRICAL CONTRACTOR UBI 179023787 Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 1489 Address 2 City SNOHOMISH County SNOHOMISH State WA Zip 98291 Phone 3605686966 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/31/1944 Expiration Date 7/31/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License STANDM *961M1 Business Owner Information Name Role Effective Date Expiration Date KOTTSICK, TODD A 01/01/1980 BUTTRUM, MEL A 01/01/1980 BUTTRUM, CLAUDIA S 01/01/1980 KOTTSICK, KAROL L 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries Electrical Contractor A business licensed by L&I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Master Electrician Information License Name Status STANDM *961 M 1 STANDISH, MILES ACTIVE https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= SERVIEC564RU 10/11/2007 6 r- ID 0 0 VICINITY MAP N.T.S. CONSULTANTS CIVIL: PACLAND 1144 EASTLAKE AVE. E., SUITE 601 SEATTLE, WA. 98109 (206) 522- 951 0 CONTACT: BOB JEWELL, P.E. BILL LINDAUER, P.E. BILL FORTUNATO, P.E. SURVEYOR: APEX ENGINEERING 2601 S. 35th, SUITE 200 TACOMA, WA 98409 -7479 (253) 473 -4494 CONTACT: MELVIN GARLAND, P.L.S. DATUM HORIZONTAL DATUM: NAD 83/91 PER HORIZONTAL CONTROL BY W.S.D.O.T. AND KING COUNTY. USED CONTROL POINTS II-IC17 -06 = BRASS CAP IN CONC. AT SE CORNER BRIDGE FOR KUaTAT AVE_ N.= 170,159.204 E.= 1,286,738.657 & WSDOT /117005 -106 = BRASS CAP IN CONC. WALK AT SOUTH ENT. TO MALL NORTH OF STRANDER BLDV. N.= 169,753.800 E.= 1,288,230504 BASIS OF BEARINGS: N7417'44 - W BETWEEN MONUMENTS USTED ABOVE. VERTICAL DATUM: PER EXISTING SURVEY BY APEX ENGINEERING PLLC UNDER FILE NO. 28368 DATED 6/11/04. BELIEVED TO BE CLOSE TO NGVD 1929 DATUM. UTILITIES CITY OF TUKWILA 6200 SOUTHCENTER BLVD. TUKWILA, WA 98188 CONTACT: 14101111111111111110111111t. (206) 433 -0179 ' I; . 1 GAS: PUGET SOUND ENERGY 10885 NE 41H STREET BELLEVUE, WA 98004 -5591 (425) 456 -2942 14- a gFr i t i P11 1 1 16 <WILA 6200 SOUTHCENTER BLVD. TUKWILA, WA 98188 CONTACT: JIIIIIIIMEWOUPPE. (206) iefra4474 k !_ ELECTRIC: PUGET SOUND ENGERY /PETELCO 14103 8TH STREET EAST SUMNER, WA 98390 CONTACT: BART WOJSZCZYK (253) 863 -0484 TELEPHONE: ()WEST COMMUNICATIONS 1600 7TH AVE SEATTLE, WA 98191 (206) 398 -2500 STRANDER BOULEVARD /WESTFIELD ACCESS /TARGET ACCESS INTERSECTION IMPROVEMENT PROJECT SOUTHCENTER MALL TUKWILA, WASHINGTON — - GOVERNING AGENCIES CITY OF TUKWILA 6200 SOUTHCENTER BLVD. TUKWILA, WA 98188 (206) 433 -1800 TRAFFIC CONTROL THE CONTRACTOR SHALL BE RESPONSIBLE FOR All TRAFFIC CONTROL IN ACCORDANCE WITH THE MOST CURRENT MUTCD AND CITY OF TUKWILA STANDARDS. THE CONTRACTOR SHALL PREPARE AND SUBMIT TRAFFIC CONTROL PLANS AT THE PRECONSTRUCT1ON MEETING. PRIOR TO DISRUPTION OF ANY TRAFFIC, TRAFFIC CONTROL PLANS SHAD. BE APPROVED BY THE CITY OF TUKWILA. NO WORK SHALL COMMENCE UNTIL ALL APPROVED TRAFFIC CONTROL IS IN PLACE WORK SHALL CEASE WHEN TRAFFIC CONTROL FAILS TO MEET MINIMUM REQUIREMENTS. TRAFFIC CONTROL MUST BE MAINTAINED 24 HOURS A DAY, 7 DAYS A WEEK. PRIOR TO WORK, CONTRACTOR TO PROVIDE THE NAME AND PHONE NUMBER OF THE 24 HOUR TRAFFIC CONTROL CONTACT PERSON TO THE CITY OF TUKWILA ♦ 4 k' > WestRe[cl NOTES: OFF SITE WORK FOR THIS PROJECT SHALL MEET OR EXCEED THE PROJECT SPECIFICATIONS, CURRENT WSDOT STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION, AND CITY OF TUKWILA DEVELOPMENT GUIDELINES & PUBLIC WORKS STANDARDS AND SPEaFICATIONS WHICH ARE HEREBY REFERENCED AS PART OF THESE PLANS. THE DESIGN SHOWN IS BASED UPON THE ENGINEER'S UNDERSTANDING OF THE EXISTING CONDITIONS. THE PLAN DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE EXISTING CONDITIONS SHOWN ON THIS PLAN SHEET ARE BASED UPON THE SURVEY PREPARED BY P.A.C.E. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING FIELD CONDITIONS PRIOR TO BIDDING THE PROPOSED SITEWORK IMPROVEMENTS. IF CONFIJCTS ARE DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE OWNER PRIOR TO INSTALLATION OF ANY PORTION OF THE SITEWORK WHICH WOULD BE AFFECTED. IF CONTRACTOR DOES NOT ACCEPT EXISTING SURVEY, INCLUDING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, HE SHALL HAVE MADE, AT HIS OWN EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR AND SUBMIT IT TO THE OWNER FOR REVIEW. CAUTION: NOTICE TO CONTRACTOR: THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTNJTIES WHICH CONFLICT UNTH THE PROPOSED IMPROVEMENTS SHOWN ON THESE CONTRACTOR SHALL FIELD VERIFY ALL UNDERGROUND UTKITY CONNECTION POINTS AND VERIFY FITTINGS REQUIRED FOR CONNECTION. CONTRACTOR SHALL EXPOSE CONNECTION POINTS AND VERIFY FITTINGS 48 HOURS PRIOR TO DISTRIBUTING SP IT- -DOWN NOTICES. MARES 11 ! oy / O7, 606 Columbia St NW Sole 606 Olympia, WA 98501 T (360) 786 -9500 F (360) 786 - 5267 www.PxLA' I c fs REVISIONS No changes shall be made to the scopA of work without prior approval of Tukwila Building Division. . " ' T E : R evisions will r e q u i r e a new plan submifial - 1 may include additional plan re'i v, lees. , DRAWING INDEX SHEET NO. DRAWING TITLE RM -1 fl review r, . .:.I C: .7-..'.; �c`. to errors and or11LSSb*. Approval of C =. - • • - •- r'-c; rot autilortte c tlN *lotion cf - •. necelpt \ fki 01111DING DIVISION C1ty of 7Wcwita j ER- CR --2.0 CR -2.1 CH -4.1 CH-4.2 TS-7.1 TS-7.2 TS -7.3 TS- 7.4 C 5. Final art-Flame is :he Public Works Jell': COVER SHEET REMOVAL AND EROSION /SEDIMENTATION CONTROL PLAN EROSION CONTROL DETAILS AND NOTES PAVING PLAN PAVING NOTES AND DETAILS STRIPING AND SIGNING PLAN STRIPING AND SIGNING DETAILS TRAFFIC SIGNAL PLAN TRAFFIC SIGNAL WIRING TERMINATIONS TRAFFIC SIGNAL STANDARD DETAIL CHART TRAFFIC SIGNAL DETAILS These Works City $tan rri fissions adopted scan for the edequ &s itner. Additions, drzaings after this w,d will require a reu for subseqCennt approval. ;ect to 'lilies ins By: fans have been reviewed by the Public mncnt for conformance with current s. Acceptance is su to errors and do not autharir rioTations of s or ordinan The responsibility the deci r rests totally with the eletions revisions to these wi void this acceptance al of rcriced drawings r -Id inspection by NO. DESCRIPTION REVISIONS a RE EIV •jllL r w i�r YY• :i: DATE RECEIVE! £LO1' 557F11E cor, • • • 20 NEW/RELOCATED ® TYPE 1 JUNCTION BOX, J -110 ® TYPE 2 JUNCTION BOX, J -110 rd rA viz( `A-0 _0 I 0-0 r 0 ONLY R3-5R ( X 361 TYPE 7 JUNCTION BOX J -11e CONDUIT CONTROLLER CABINET VEHICLE SIGNAL HEAD PEDESTRIAN SIGNAL HEAD EMERGENCY VEH PREEMPT DETECTOR STREET NAME/REGULATORY SIGN 6' X 30' VIDEO DETECTION ZONE TYPE III SIGNAL STANDARD PEDESTRIAN PUSH BUTTON POST ELECTRICAL SERVICE CABINET VIDEO CAMERA (ON MAST ARM) WIRE NOTE CONSTRUCTION NOTE SIGNAL STANDARD NO. to LEGEND GRAPHIC SCALE 20 (IN FEET ) AS SHOWN SIGNS D3-301 (MOD.) Or X 12') LETTER SIZE 60 • 2 10 LEFT 1 TURN MUST I YIELD R10 -1201 (30" X 36') ISTRANDER BLVD SEE SHEET CH -4.1 FOR ADDITIONAL 9004G. • NEW LED. VEHICLE SIGNAL HEAD NO. 21, 22, 41, 42, 61,62,81,82 NOTES: 1. ALL VEHICLE HEADS SHALL HAVE 12" L.E.D. LENSES, BACK PLATES AND TYPE M MOUNTS, SEE J -6g. 2. ALL VEHICLE SIGNAL HEAD, VISORS AND BACK PLATES SHALL BE ALUMINUM. 3. ALL PEDESTRIAN HEADS SHALL BE L.E.D. WITH TYPE 'E' MOUNTING EXCEPT HEADS 168 & 149 WHICH SHAD. BE TYPE D. AND 28 &89 WHICH SHALL BE TYPE A. 4. ALL PEDESTRIAN PUSH BUTTONS SHALL BE POLARA "BULL DOG" STYLE. SEE POLARA DRAWING 1RBDLM2 -X -YY. SO 0 12" 12' SIGNAL DISPLAYS NEW 1 1 t LE.D. , NEW LE.D. '.VEHICLE SIGNAL s PEDESTRIAN HEAD HEAD NO. 31, 71 28, 29, 48, 49, 68, 69, 88, 89 7 +00 - - I VIDEO ZONE 71 12" 12' 12" WESTFIELD ACCESS SEE TS -7.2 FOR MAST ARM WIRING (TYP.) I VIDEO ZONE 41 I I VIDEO ZONE 42 I 69 CONSTRUCT FOUNDATION AND INSTALL TYPE III SIGNAL STANDARD IMTH 40' MAST ARIA VEHICLE SIGNAL HEADS, PEDESTRIAN SIGNAL HEADS, PUSH BUTTON ASSEMBLIES. PRE- EMPTION DETECTOR, 250 WATT HPS MC -III LUMINAIRE AND 12' LUMINAIRE ARM, VIDEO CAMERA AND TERMINAL CABINET PER SIGNAL STANDARD DETAIL CHART. CONSTRUCT FOUNDATION AND INSTALL TYPE W SIGNAL STANDARD WITH 25' MAST ARIL, VEHICLE SIGNAL HEADS, PEDESTRIAN SIGNAL HEADS, PUSH BUTTON ASSEMBLIES, PRE - ONION DETECTOR, 250 WATT NIPS MC-IN LUMINAIRE AND 12' LUMINNRE ARM, VIDEO CAMERA AND TERMINAL CABINET PER SIGNAL STANDARD DETA L CHART. CONSTRUCT FOUNDATION AND INSTALL TYPE PS PEDESTRIAN STANDARD WI TN PEDESTRIAN SIGNAL HEADS AND PUSH BUTTON ASSDIBUES PER SIGNAL STANDARD DUAL CHART CONSTRUCT FOUNDATION AND INSTALL TYPE II SIGNAL STANDARD WITH 40' MAST ARM, VEIDCE.E SIGNAL l EAD6, PEDESTRIAN SIGNAL HEADS, PUSH BUTTON ASSEMBLIES, PRE- ETNPT1ON DETECTOR 250 WAIT SIPS MC - LUIMARE AND 12' LUMINAIRE ARM, VIDEO CAMERA AND TERMINAL CST PER S GhAL STANDARD DETAX. CHART CONSTRUCT FOUNDATION AND INSTALL TYPE PS PEDESTRIAN STANDARD 'ACTH PEDESTRIAN SIGNAL HEAD AND PUSH BUTTON ASSEMBLY PER SIGNAL STM4MR0 DUAL CHART. B8/ D VIDEO ZONE 61 VIDEO ZONE 62 82 VDD 81 PROPOSED EASEMENT FOR - SIGNAL MAINTENANCE (TYP.) NOT USED. t • s to \ IN FEET ) AS SHOWN 13 0 NOTE: SEE SHEET TS-7.2 FOR GENERAL NOTES `. AND WIRING SCHEDULE. 31 8 +00 0 - -- - - - STRANDER BLVD_ STA. 08 +26.63 = �- 0 WESTH I ACCESS STA. 10+ 21 122 AA/DA # - 1 \ 71 B 41 VDU 42 I - 4 8 W VJ On I w ao 40 I-4 29 I I VIDEO ZONE 82 I I VIDEO ZONE 81 - •9 +00 • PROPOSED EASEMENT FOR SIGNAL MAINTENANCE (TYP.) TRAFFIC SIGNAL CONSTRUCTION NOTES 6 CONSTRUCT FOUNDATION AND INSTALL TYPE HI SIGNAL STANDARD U WITH 30' MAST ARM, VEHICLE SIGNAL HEADS. PRE- E11P1ON DETECTOR, 250 WATT HPS MC -IN LUMINAIRE AND 12' LUMINAIRE ARM, 1+1DEO CAMERA, CLOSED CIRCUIT TELEVISION (CCTV) CAMERA DOME, AND TERMINAL CABINET PER SIGNAL STANDARD DETAIL CHART CONSTRUCT FOUNDATION AND INSTALL TYPE PS PEDESTRIAN STANDARD WITH PEDESTRIAN SIGNAL HEAD AND PUSH BUTTON ASSEMBLY PER SIGNAL STANDARD DETAIL CHART. SEE SHEET RM -1 FOR LIGHT STANDARD REMOVAL. CONTRACTOR TO FURNISH AND INSTALL STRETCH -P CONTROLLER CABINET, EAGLE EPAC 1150 NEMA CONTROLLER AND ASSOOATED HARDWARE. THE CONTROLLER CABINET SHALL BE FIELD LOCATED BY THE EN(1EER_ THE OTY OF TUN(yVILA SHALL TEST THE CONTROLLER AT THE CONTRACTOR'S EXPENSE. INSTALL CONTROLLER CABINET ON FOUNDATION PER MANUFACTURER'S RECOI UENDATION. SEE SPECIAL PROVISIONS. CONTRACTOR TO AMISH AND INSTALL SOME CABINET PER CITY OF TUA(WtLA STANDARD DETAIL RS -22. SERVICE CABINET SHALL BE FIELD LOCATED BY RE ENGINEER. INSTALL SER1iICE CABINET ON FOUNDATION PER MANUFACTURER'S RECO/A ATION. OPEN TRENCH CONDUIT CROSSING BACKFILL LATH 5/8' MINUS COMPACTED CRUSHED ROCK AS SPECIFIED IN OTY OF RAG A STANDARD DETAIL RS -03, LATH A/C TO MATCH EXISTING. • L ZONE 31 H STRANDER BOULEVARD • r f PRE -EMPT PHASING A -02 B-04 & 07 C-06 0 -43 808 1 1. MAIN BREAKER 2. BRANCH BREAKER (I.LUM.) 3. BRANCH BREAKER (SIGNAL) 4. BRANCH (CONTROL CIRCUIT) 5. CONTACTOR (Ltuu.) 6. BRANCH (GROW) FAULT RECEPTACLE) 01 02 03 04 i NOT USED t;. NOT USED 1 1 . 05 06 07 08 VEHICLE MOVEMENT —► PEDESTRIAN MOVEMENT s-// PHASE SEQUENCE DIAGRAM 10+00 -1— . /. N t : • • • I NOTE: THE CITY SHALL FURNISH ZIIIIIMMICr ALL VIDEO CABLING_ THE CITY OF TUKWILA WILL INSTALL ALL VIDEO EQUIPMENT INCLUDING CCTV DOME. CONTRACTOR SHALL FURNISH ALL VIDEO EQUIPMENT. SEE PROVIDED CATALOG CUT SHEETS, AS APPLICABLE FOR THIS PROJECT. '- - CONTRACTOR TO COORDINATE WITH PUGET SOUND ENERGY FOR TRAFFIC SIGNAL SERVICE CONNECTION & INSTALLATION OF POWER VAULT_ REPLACE EXISTING JUNCTION BOX YATIH 25-TA COMMUNICATIONS PULL BOX (FOR FIBER OPTIC INTERCONNECT PATCH.) INSTALL 12 COUNT "GATOR PATCH” IN VAULT_ ROUTE "GATOR PATCH" PIGTAIL TO CONTROLLER. SERVICE CABINET BREAKER SCHEDULE - 100 AMP (2 POLE) - 15 AMP (2 POLE) - 30 AMP (1 POLE) - 15 AMP (1 POLE) - 30 A.UP 2 POLE 120 VAC COIL - 15 AMP (1 POLE) n la 11- • • SOUTHCENTER 633 Southcenter - �toII Tukwilo. WA.. 98188 -2888 206 -246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 DNS ORAMC IS AN PISIRUY07T OF SERIACE. IS THE PROPERTY O De. AROIITECT AND DAY Nor 8E REPRODUCED 111H011T DIE ARCHITECT'S PER11690N AND MESS DIE REPROOUCIION CARRIES THE ARoe'rcrs NAIL AU. CC901 AND OTHER Mi0RIIADON 9IOWl ON TIE ORAWiiC ARE KR USE ON THE SPcanm PROJECT ONLY AND 91AU. NOT 8E uSED OTHERWISE: WITHOUT WRITTEN Pei:MISSION FROM THE ARGIITECT Registration No. Consultants E1PRRPS u/b1/m [ El: ICA ;-; AS 1„ iffi li l -S A „ IP) ' 606 Columbia St. NW T (360) 786 -9500 Suite 606 F (360) 786 -5267 Olympia. WA 98501 :•r> Y1_PAcL.to.CON Approvals: A A__ A A - A Sheet Title Job No. • No. Revision Dote TRAFFIC SIGNAL PLAN Dote Scale TS -7.1 RECEal Fr • �r,T w* , C • WIRING SCHEDULE RUN NO. CONDUIT SIZE* 721 wiRE /CABLE E. L DETECT 3C(S) 5C 581 :•: ILLUM 0 POY.ER j SERVO r2 VIDEO CABLE INTER - CONNECT RE'IAP::S 1 1.5 i • 1 742 5C3 : 743 501 0 P'E 2 2 ' 1 5D3 •; 761 2 762 1.5 763 2 3 3t 69192 3 782 T 783 2' 1 2 1 1.5 2 4 - 2 , 1.5 2 5 3 ' 7 3 ' 2 3 1 1.5 2 6 3 4 , 2' I _ 1 1.5' 2 7 1.5' 2 8 2 ' 1.5' 2 ' 9 1.5' 1 2' 1 1 , 1.5' 2 I 10 4' 14 31' 4 5 1 1.5' _ 2 • 11 1.5' 2 12 1.5' 2 13 2' 14 2' - 1 15 2' 3 - , 2' I 1 5A1 :f; A 62 721 5A3 :s: 722 581 :•: 723 B 562 :.: 513 0: 5C1 • i • 741 742 5C3 : 743 501 0 P'E C 5D2 :•: 5D3 •; 761 762 763 rE 781 69192 782 783 5A1 :f; A 5A2 :• 5A3 :s: 581 :•: B 562 :.: 513 0: 5C1 • i • C 5C3 : 501 0 C 5D2 :•: 5D3 •; 4 SIGNAL HEAD 31 SIGNAL HEAD 81 SIGNAL HEAD 82 � 631 - 632 633 634 636 R.- 671 - 672 673 674 676 R- O- G B w R- O- G w 1 - 5C 1 -5C R - 681 - Y G 682 683 684 686 'G 623 R ■621- Y: 622 624 - 626 - R 641 - Y 642 - G 643 - 644 646 r 661 662 663 664 . 666 R G w 1 -5C POLE NO. 1 SIGNAL HEAD 21 SIGNAL HEAD 22 R- O- G B - w- POLE NO. 2 R - 0- G B w- 1 -5C P.P.B. 28 SIGNAL HEAD 71 SIGNAL HEAD 41 SIGNAL HEAD 42 -5C POLE NO. 4 SIGNAL HEAD 61 -R -O -G -W -5C POLE NO. 6 R -681 - 682 683 684 686 R Y G 0 R B w POLE NO. 5 SIGNAL HEAD 62 POLE NO. 621 -R- 622 -0- 623 - G- 624 -B- 626 -w- 641 642 643 644 646 FIELD WIRE TERMINATIONS R G B W 1 -5C 1 -5C - 721 722 - 723 1 -5C POLE NO. 3 - -R 0 - G - w 1 -5C 0 G B w P.P.B. 49 1 -5C TERMINAL CABINET 1 -- 0 \-w -R -0 -G t- w TERMINAL CABINET 2 ^R= --G= PED. HEAD 28 P.P.B. 89 681 682 683 684 686 631 632 633 634 636 R O R- 0 G I B 621 R -- 622 0 623 G- 624 B- 626 W-- 641 642 643 644 646 671 672 673 674 676 R 0 - G - w R G w TERMINAL CABINET 1 R - O - - G B - - - R PED. HEAD 49 0 R G - 742 741 e B - V -z I 7 , 1 -5C TERMINAL CABINET 2 --R 661 R- --0- 662 O- G= 663 G- - B A664 B - Y: 666 w - P.P.B. 68 PED. HEAD 68 8 0 R 7s2 61 I or I if I 7 W 763 j I 1 - SC PED. HEAD 89 - 781 782 - 783 1 -5C P.P.B. 88 P.P.B. 69 0 B 0 B E.V.P. D 0- -BL a 5D1 502 503 VDA E.V.P. A 5 11 V 5A2 Y 5A3 8L P.P.B. 29 f)) . . . 1,. ca a 5.9! 582 5B3 TO CONTROLLER CT 0 E.V.P_ C 5C1 O 5C2 Y 5C3 BL TO CONTROLLER w G w R G PED. HEAD 88 1 -5C PED. HEAD 69 TO CONTROLLER 1 -5C 1 -3CSH 1 -5C 1 -5C TO CONTROLLER VIDEO CABLE VIDEO CABLE 1 -3CSH 1 -5C PED. HEAD 29 1 -5C 1- 2CS 1 -5C 1 -3CSH 1 -5C 1 -5C DM. :tr ^, 4:9 TO CONTROL I FR VIDEO CABLE f0 CON T RO..L ER TO CONTROLLER VIDEO CABLE VIDEO CABLE 1 -3CSH 1 -5C • POWER - -O R 632 631 - 633 - B 634 - w 636 R 681 0 w 682 G 683 B 684 686 DISPLAYS OD TO CAMERA: DUAL- ELEMENT - �-- -� ENE -CCi UCTOR • CABINET WIRE TERMINATIONS U rrr Yyy 0 BL Y 0 BL Y 0 BL O BL - R -0 642 -G 643 • -B -w R O G B w DISPLAYS E.V.P. KEY: B - BLACK W - WHITE R - RED Br - BROWN BI - BLUE TO CONTROLLER: DUAL- ELEMENT FIVE- CONDUCTOR VIDEO SPLICE CABINET DETAIL (FOR INFORMATION ONLY. THE aTY SHALL UTILIZE ITERIS VIDEO CABLE.) - R - 0 - G - B -w R - G= w� G w G w R G w DISPLAYS NOTES: 1. RG -59 COAX CONNECTOR 2. WIRE NUTS 3. INSULATED MALE /FEMALE SPADE CONNECTORS 4. CGB WEATHERTIGHT FITTINGS 5. ENCLOSURE * ALL CONDUIT SHALL BE SCHEDULE 40 PVC, EXCEPT UNDER ROADWAYS AND DRIVEWAYS,, IN 11IICH CASE RGS SHALL BE USED. PROMO( GROUNDING WRE SYSIDI AS NECESSARY_ PED. DISPLAYS 1. NOTES: -0- PED. BUTTONS NOTE: CONTRACTOR TO PROVIDE VIDEO CARDS IN CONTROLLER AS NECESSARY. ® CONNECT TO TO NETURAL BUSS CONTROL SIDE TERMINAL CONNECTION El SPARE CONNECT TO DETECTOR COMMON BUSS -R - - - -w DISPLAYS 0� 0 B- O : B= B= - -I 724 725 744 745 764 765 784 785 4 STRANDER 1 BOULEVAR Z LEGEND STRANDER BO ULEVARD l�f� �j • �V� � W v) U U Ida LOCATION OF UNDERGROUND UTILITIES ARE APPROXIMATE. FOR EXACT LOCATION, CONTACT UTILITY LOCATE (1 800 - 424 - 5555). POTHOUNG FOR DEPTH AND HORIZONTAL LOCATION IS RECOMMENDED AT CROSSING LOCATIONS AND AT SIGNAL POLE FOUNDATIONS. 2. THE CONTRACTOR SHALL POTHOLE All SIGNAL POLE LOCATIONS PRIOR TO ORDERING SIGNAL POLES AND ANCHOR BOLTS. MAST -ARM LENGTHS AND TENON LOCATIONS MAY NEED TO BE ADJUSTED IF FOUNDATION LOCATIONS MUST 13E REVISED TO AVOID CONFLICTS. ALL ADJUSTED FOUNDATION LOCATIONS AND POLE CHANGES SHALL BE APPROVED BY THE ENGINEER PRIOR TO ORDERING POLES. 3. CONDUIT RUNS AND JUNCTION BOX LOCATIONS ARE SHOWN IN APPROXIMATE LOCATIONS. FINAL LOCATIONS MAY BE ADJJSIED TO AWID CONFLICTS AND FOR EASE OF CONSTRUCTION_ FINAL LOCATIONS FOR CONDUITS AND JUNCTION BOXES SMALL BE APPROVED BY THE ENGINEER PRIOR TO EXCAVATION. 4. CONTRACTOR TO BE RESPONSIBLE FOR REPAIRING EXISTING SIDEWALK, DRIVEWAYS, LANDSCAPING, ETC. TO THEIR ORIONAL CONDITION IF AFFECTED BY INSTALLATION OF THE TRAFFIC SIGNAL SYSTEM. 5. SIGNAL TIMING AND PHASING SHALL BE INSPECTED AND APPROVED BY art OF ItE*LA. 6. THE CONTRACTOR SHALL 8E RESPONSIBLE FOR AM TRAFFIC CONTROL IN ACCORDANCE WITH THE #IUTCO M&NUAL PRIOR TO DISRUPTION OF ANY TRAFFIC. TRafFIC CONTROL PLANS SHALL BE PREPARED AND SUBISTWD TO DIE an' FOR APPROVAL NO VIRRK SHALL COMMENCE UNTIL ALL APPROVED TRAFFIC CONTROL IS Di PLACE. WORK SHALL CEASE MIN TRAFFIC CONTROL VMS TO MEET MAMA REQUIREMENTS. 7. ALL EXISTING BRC(EN OR DAMAGED CONCRETE CURB. GUTTER AND SIDEWALK SHALL BE REPLACED. i 331iiie&t SOUTHCENTER 633 Southcenter Mal Tukwao, WA., 98188 -2888 206 - 246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025-1748 Telephone 310 478 4456 Facsimile 310 478 4468 Ras ORAW4INC IS AN INS1RMIFNT OF SEFMIX. IS TILE PROPERTY OF TIC ARCHHTECT AND WAY NOT OE REPRODUCED 111THOUT DC ARCHITECT'S Poa.S9oN NO UNLESS THE RIPRODUCDON OAKS THE ARDAIECrsS NAME NJ. DESCH APO OTHER INFORNATIM SWAN ON THE DRAID4C ARE FOR WC ON THE SPECIFIED PROJECT ONLY AND SIAM NOT OE USED OTHERWISE WMTHOUT MITTEN PERUIS90N FROM THE ARCHITECT Registration No. O Consultants Approvals: t WIRES 11/04/07 LAcciffi:. 606 Columbia St. NW T (360) 786 -9500 Suite 606 F (360) 786 -5267 Olympia, WA 98501 www.PAcLANo.oDm - S - tT- No. Revision A- A A A Q Sheet Title TRAFFIC SIGNAL WIRiNG TERMINATUNS Job No. 200518110160 Dote Scole 34 TS -7.2 p : --- kir,... :..i.... r -:. RECEN Er Dote FErA C EN T t a FOUNDATION DEPTH TABLE ALLOWABLE LATERAL BEARING PRESSURE FOUNDATION XYZ (CUBIC FEET) TYPE II.III AND SD MAST ARM STANDARDS (Ps1) TYPE 600 900 I 1,200 1,500 1,900 2,300 3 SEC110N 12' 3' ROUND 16.5 19.2' 11' 11' 13' 15' 1,000 3' SQUARE 10 REMARKS 9' 9' 10' 11' (POLE 85 4' ROUND 16.5 17.0' 9' 9' 10' 11' 16.5 3' ROUND (x}(YXZ ToTAL(M 710 B7 B11 C s Rik 8 15' 1,500 3' SQUARE iN 'r. f. 17.0' , 9' 16.5 4' ROUND 16.5 19.6' 90 I 135 9' 7 3' ROUND STRANDER 7 +75 37.5' 11' 15' 2.500 3' SQUARE lb 10 27.5 6' 7' 17.5 4' ROUND 8.7 6' 7' SIGNAL STANDARD DETAIL CHART 40' 45' 50' 53' -150' MIN. 1 MAX. MIN- MAX. MIN. MAX_ MIN. MAX. 3 SEC110N 12' 16.5 i 17.5' 16.5 19.2' 16.5 20.9' 16.5 22.0' 11 12 270 FOUNDATION DEPTHS(FT) REMARKS OFFSET B1 DISTANCES 82 (FT) B3 (Z) 84 (POLE 85 4 SECTION 12" 16.5 17.0' 16.5 18.0' 16.5 19.7' 16.5 20.8' (x}(YXZ ToTAL(M 710 B7 B11 C s Rik 8 s so 7 4 R STATION 5 SECTION 12" 16.5 17.0' 16.5 17.5' 16.5 18.5' 16.5 19.6' 90 I 135 0 7 STRANDER 7 +75 SIGNAL STANDARD DETAIL CHART STD' No_ ROADWAY REFERENCE FIELD LOCATION TY'E uouNTlN� HEIGHT(FT) Al A2 35 S IGNAL MAST ARM DATA LUMINAIRE ARM(FT) POLE D ATTACHMENT El E2 POINT F G1 ANGLES G2 **(deg) H 11 12 270 FOUNDATION DEPTHS(FT) REMARKS OFFSET B1 DISTANCES 82 (FT) B3 (Z) 84 (POLE 85 TO ATTACHMENT 86 07 POINT 811 B1 1MNOLOAD B2 AREAS B3 B4 F z B6 X Y (x}(YXZ ToTAL(M 710 B7 B11 C s Rik 8 s so 7 4 R STATION OFFSET LT. P.O.A. 12 0 0 90 180 135 0 7 STRANDER 7 +75 37.5' X 0 Ill 19 36.5 27.5 30.5 17.5 8.7 8.7 8.7 57.5' X 90 In 19 35 24 21 16 10 8 8.7 7.5 8.7 6 554 . 12 0 0 . 135 8 7 7 2 STRANDER 8 +55 3 36' X PS 8.7 1 87 _ 8.7 723 12 0 0 180 90 270, 180 135 0 0 90 270 8 7 7 SEE WSDOT STD PLAN J-70 STRANDER 8 +64.5 4 8 +53 38 X 0 III 19 37 28 31 18 STRANDER 35 180 90 SEE WSDOT SID PUN J-7o 5 STRANDER 8 +06 39' X PS 6 _�. X 90 III 19 25 18 14 8 8.7 7.5 8.7 6 645 12 0 0 135 g 7 7 l ' (SEE ASTERISK BELOW) STRANDER 7 +92 38 7 270 0 SEE MOOT STD PLAN J-7o STRANDER 7 +66.5 34.5' X PS _ ! 1 t a. Vehicle Display b. Sign c. Street Name Sign d. Pre -Empt Detector e. Deleted (10/22/90) NOTES 0 MOUNTING COUPLING INSTALLED AT OFFSET DISTANCE INDICATED IN CHART. FIELD INSTALLED. 3/4" CHAMFER UNPAVED SURFACE CLASS 3000 CONCRETE 8 NO. 8 BARS EQUALLY SPACED LEGEND Tit tit '!'I tiles 2-1/2" CL #4 HOOPS. RD. OR SO. AT 1' -0" APPROX. C i RS. 3' SQ. OR RD., OR 4' RD. 1 } 9- h. f. Luminaire Pedestrian Cabinet i. PPB ---M Handhole 3/8 • Display 4 , N v' FOUNDATION DETAIL Sb ,wy POLE ORIENTATION LINE DIA. PLASTIC DRAIN TUBE GROUT PAD THICKNESS= NUT HT. +1" MAX PAVED ANCHOR BOLT PLATE POLE ORIENTATION AND ATTACHMENT POINT DETAIL SURFACE O= NTATj L, I- CL r ; TYPE PPB PPB POST * INSTALL 1 1/2" NATIONAL PIPE THREAD COUPLER 1.5' FROM END OF LUMINAIRE ARM. COUPLER SHALL BE FLUSH ON INSIDE. NF NIO" ----POLE ORIENTATION ANGLE (P.O.A. DEGREES CLOCKWISE FROM OFFSET UNE TO POLE ORIENTATION UNE (SETS ANCHOR BOLT ORIENTATION) 1 ATTACHMENT POINT ALL HANDHOLES AT 180' FROM El * IF E1 OR E2 SIGNAL ARM IS NOT NINETY DEGREES TO THE ANCHOR BOLT PLATE THEN SPECIAL DESIGN POLE LOCATION STATION TYPE PS PED. HEAD STANDARD • THIS TABLE BASED ON A / 0/ALUE OF 26'. FOR DOUBLE MAST ARM STANDARDS WITH 90' BETWEEN ARMS, USE THE LARGER XYZ VALUE FOR FOUNDATION DEPTH SELECTION. A SPECIAL FOUNDATION DESIGN IS REQUIRED FOR DOUBLE ARM STANDARDS IF THE ANGLE IS NOT 90. TYPE I VEHICLE HEAD STANDARD 0 0 r B1 B2 TYPE II MAST ARM SIGNAL STANDARD B3 B4 SIGNAL STANDARD IDENTIFICATION TAG DETAIL EXAMPLE NOTE: CORROSION RESISTANT METAL TAG SECURED WITH (2) 0.125" RIVETS AS FOLLOWS: POLE SHAFT -- LOCATED WITHIN 6" ABOVE HAND HOLE, SIGNAL AND LUMINAIRE MAST ARM -- LOCATED WITHIN 6" OF THE POLE SHAFT CONNECTION POINT. TEXT SHALL BE A MINIMUM OF 3f6" HIGH, STAMPED OR EMBOSSED. TYPE III COMBINATION LIGHTING AND MAST ARM SIGNAL STANDARD STD. NO. XX SRXXX, MP XXX.XX MANUFACTURER APPROVED DWG. XXXXXX FAB. X /XX /XXXX B6 SIGNAL DISPLAY VERTICAL CLEARANCE ( FEET) FROM STOP LINE ROADWAY B7 LIMITS OF VERTICAL CLEARANCE REQUIREMENT TYPE IV STRAIN POLE STANDARD T H I SIGNAL STANDARD NO. STATE ROUTE AND MILE POST NO. APPROVED DRAWING NO. FABRICATION DATE Vr� i B10 b h C B11 C 1 E STD. NO. 02 SR97, MP 069.09 MANUFACTURER APPROVED DWG. AB12345 FAB. 6/14/2002 i D L p� COM NEC NFpa� a It) 2001 My Of 'C I rB11 --1N D or b L 9 T F G 1 Q (V 1 N Q TYPE V -CURB OR EDGE COMBINATION LIGHTING OF SHOULDER AND STRAIN POLE STANDARD TYPE SD SPECIAL DESIGN STANDARD If �fiW S OUTH CENTER 1115 BR/TANG IS AN 1i4S1RIAENT OF SERIACE. IS THE PROPERIY OF DE ARCHITECT ARO VAY NOT BE REPRODUCED **OUT BE ARCHITECT'S PERIIS9p 1 AND MESS THE REPRODUCTION CARRIES THE AR001ECrs NAut. ALL BESPON AND OTHER P ORLAAON 9$011N ON THE BRAw'C ARE FOR USE ON THE SPECIFIED PROJECT ONLY NO SHALL NOT BE USED OTHERVASE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT Registration No. 1 0' Consultants WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles. California 90025-1748 Telephone 310 478 4456 Facsimile 310 478 4468 606 Columbia St NW Suite 606 Olympia, WA 98501 Approvals: No. Revision A- A__ Sheet Title Job No. 633 Southcenter 11on Tukwila. WA.. 98188 -2888 206- 246 -0423 @6 BES 11/04/07 1 l ` =. f'i: ;,iii TRAFFIC SIGNAL STANDARD DETAIL CHART TS -7.3 T (360) 786-9500 F (360) 786 - 5267 www.PAdAlo.aas Date Sco!e mos RECE Date • • • • • I • • C, m M , • •1 , . !A jh'i (.7/ 2. Aa�T LOGIN: ,., . • PA •H j \'h ,V „ny• . •'��... w 7 \M•� d �•,,. r• :n• . �• 1' :• ^ �1 1. � 1A(tS II A9 "2 9Ab LE) C C rn C) C T 1 C• ) C7 C C �� .• 1 1 Ih Ph CA i r• 4 1.'A "TRAPICON" CAMEPA NOl:N1 !'v:; BRACKET r (NO MOLE IN GOT TOW ... • • •••• • 44 III MEMO. 4.1 •.00 J4 •..,r, • UL'ST 6044 U CONSIINV'I' U CoRI: v 1......A 1.1 `.1 A,,..1 1...1 1300 .•r w.••�••r• a N ....e..., ET 1401 y 1DID o y !0 I I M 1 l e ,._._., ,i4 _• -_•__ LA Oi •••• City of Tukwila .4`• 0 0 CD 14% CONDUIT LANG 3 114 IQ,NwIT ZONE & ANCHORT LOCATION RGVISION II• 08,03 I APPROVAL B, SHELTON 64.4 4l1NCII3 BOY DRIP LO0a . PELCO ASTRO BRAC OUSSETEO TUBE. 11/2” X VAR, LENGTH w /VINYL INSET PART NO. AB- 20030. �. — SIONAL MAST ARM tlfflltlltlf,Mft fttll PELCO PROCUC7S INC, ASTRO BRAG . Yt)JJ1�• '1'111: CONTRACTOR SHALL DRILL A V' 1101,B IN Tim RACK MDR OP THE SIGNAL MAS1'.\k3:, Cfl LII;Itk, dr ma A RUBBER OROMMP1' IN HOLE. THE ASTRO ARACKET SHALL DE INSTALLED OVER THE I" 1101,L1. VIDEO CALIi1.LS SHALL BE PUt.LRI) T1IRC)UGH THE, SIC NAL MASTARM, TI !ROUGH THE I•' HOI .r. AN. ) TIIROIiOH TILE ASTRO VRACKET. IIO%.T IBS" OUS$ En TWA TO ASTRO BRACKET. ATTATCII vIDY•O CAMERA MOUNTING URACKET TO TILE TOP MW TI in GUSSETS!) TURF. ROUTE VIDEO CABLES IN GUSSET ANU CONNECT TO V1DflO3 NOTION INSIDE VC4 r DRIP L()OP LN CABLES, AT MP nF' INSTALL VINYL INSERT IN OUSSET, UTAVINO NO MORE THAN A 1" OAP AT 'rim TOP RA ('.%I%1 L;xn. nIt TUA11. W1'rALI. 2 %!LACK Wt(A't112R RATRI) WIR1( TIES AROUND) TUUI; %Al EAU: CABLES UxIT AT 111E TIN' VI TUE VINYL INSERT. 'TYPE "P" CABINET RS•20 NOTES o 1, ALL DIMENSIONS IN INCHES 2. CITY PROVIDL:S 3 PHASE NEMA CONTROLt. U. UNI.FSS OTHERWISE DIRECTED. 3. FOUNDATION SHALL MEET OR EXCEED FOUNDATION I)C MAIL ON WS0O7 STANI ARO PLAN J.39. • 4. CABINET SHALL BE ANODIZED ALUMINUM, 0.123" THICK, 5052 SERIES, NEMA 3R. NOT 1'0 SOALL TRAFFIC SIGNAL_._ CONTROLLER CABINET t111CRT: tO0 yr 011 r 120.240 vAG,1 0). 3 %AAA, WIRING S011f.MATIC • ;AI N "OT COMPONE SC + ,� � `,:� �,,, 1 !fr 1 f�BNT � +SC. HEDULE 1 ':'Z' i ,fv F JAW Ay; u 71:'31.1. (.� • F . 3 . A..S EL . •.10:• (:(:r I :A!; t(•'t r'�,; a:11 FY AI'11 SER'�:;.r. 1 1;1 I • '�': � : ;If )t.!2;) 1.'''',':;1'1.AC. • •,) Amp. 10;:;,ri ',lid•IZL. C Or 3JS 7 . 15 'IN.ro'):;sr• City of Tukwila • t; MA.`. I • I5'2 'I.I. NiNA "'ION ORANCI' 1 • : r1 SIGNAL BRANCH 1 - 15/1 CONTROL CKT BRANCH 1 •2011 OFR BRANCH 3, CONTACTOR: LIGHTING RATED, 30 AMP, 2 POLE, 120 VAC COIL, 1 REQUIRED '1, pupLlsX RECEPTACLE, 120 VAC, GF! PHOTOCELL BYPASS SWITCH. SPST, 15 AMP, 277 VAC ti 'ERMINAL BLOCK TO REMOTE PHOTO ELECTRIC CELL NEMA 3R, PADMOUNT.118" ALUMINUM CONSTRUCTION REMOVABLE EQUIPMENT MOUNTING PAN, HINGED DEADFRONT 2 SCREENED AND GASKETED VENTS DOORS: HEAVY DUTY CONCEALED HINGES (LIFT-OFF TYPE) STAINLESS STEEL VAULT HANDLES PADLOCKABLE METER DOOR w/POLISHED WIRE GLASS WINDOW BEST CX LOCK W/BLUE CONSTRUCTION CORE ON DISTRIBUTION DOOR CLOSED CELL NEOPRENE GASKET, CARD HOLDER FINISH: BARE ALUMINUM OUTSIDE, WHITE POLYESTER POWDER COAT INSIDE NOT TO SCALE AUSNIN0 LOCK •I12TS TERMINAL SOX MIK)NT I' MIN. t•kUM SOX 411C 430.'4.tAT€ v,$crt PUSH BUTTON POSITION STEEL POUR 1.112'x 1.112• CHANNEL PUSH BUTTON ATTACHMENT 7 2:1' I YP. r;LAM$NE( PAINT ARROW ON M ?tI11TINJ PUSMDUIION (2 9IOES A TOP) �.�^ �� P H syrI N 10 AVIVATO 'MLR IN Nis oIRF INSTALL PUSIIDUTTON 42' i•ROLl OROUNO AAPRS 4100EL n01371412 PEDESTRIAN SIGNAL - 2.1or PLUNOL'k YtIT1 r CI 1RO NIt rlNfSa NOT TO SCALE City of Tukwila I OWE fffftf'•••111 A•111 ii M elk gob AsIXRI EB Wei ggi .g • 2• "' r C:2 ••••• i O � j PLAN VIEW OF usg RIV%SION n1: 08.03 APPROVAL: B. SHELTON J. 1. V ': •t • ■ ; RS -22 RS -23 rite /1310Y It 08•03 ArPPrt0VAI B SHELTON 7 1 —I 3 g o � � cft Z 0 0 > t� V y 2 00030 5 2) - .A = a z z 03 Co A. 4 °? 0,CO 2d• C.,r • :ttr:,' .l SERVICE CABINET PEDESTRIAN SIGNALS , 3AU J