HomeMy WebLinkAboutPermit EL07-582 - PANDA EXPRESSPANDA EXPRESS 17100 SOUTHCENTER PY STE 100 ELO7-582 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: LUPE SANDOVAL Address: 1127 E OLIVE AV , FRESNO CA Contractor: Name: POLAR ELECTRIC LLC Address: PO BOX 854 , REPUBLIC WA Contractor License No: POLAREL974N1 Expiration Date: 08/11/2009 DESCRIPTION OF WORK: ELECTRICAL FOR NEW TI 2623049081 17100 SOUTHCENTER PY TUKW WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE WA Fees Collected: $676.50 Type of Fire Protection: National Electrical Code Edition: 2005 Value of Electrical: $28,000.00 Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PANDA EXPRESS 17100 SOUTHCENTER PY SUITE 100 , TUKWILA WA Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Signature: Print Name: doc: EL -4/07 A- 0A -7 po c ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 559 268 -2711 Phone: 509 775 -0907 ELM-582 12/12/2007 06/09/2008 A f\k/C7 �Q Date: � 2 `17.I ( n_ I hereby certify that I have read and e ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied • hether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Date: 1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. EL07 -582 Printed: 12 -12 -2007 Parcel No.: 2623049081 Address: Suite No: Tenant: 1: ** *ELECTRICAL * ** 17100 SOUTHCENTER PY TUICW PANDA EXPRESS 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: doc: Cond -Elec d� Print Name: ,41 t -t O•-y Do12 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:• / /www.ci.tukwila.wa.us Yr` / PERMIT CONDITIONS Date: Permit Number: Status: Applied Date: Issue Date: J ?i / 1 2 1 ELO7 -582 ISSUED 10/12/2007 12/12/2007 EL07 -582 Printed: 12 -12 -2007 SITE LOCATION CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 h t tp: / /www. ci. tkwila. wa. us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 2-(P 30J - I - 'T R Site Address: 17100 Southcenter Parkway Suite Number -14- 100 Floor: Tenant Name: Panda Express Restuarant New Tenant: ® Yes ❑..No Property Owners Name: Wig Properties, LLC - Mailing Address: 4811 134th P1 . SE Bellevue City WA State 98006 Zip CONTACT PERSON — Who do we contact when your permit h ready to be issued Name: Vigen Architect Mailing Address: 1127 E . Olive Ave E - Mail Address: lupe@vigen.com ELECTRICAL CONTRACTOR INFORMATION To Be Determined Lupe Sandoval Day Telephone: (559)268 Fresno CA 93728 Cit State Zip Fax Number: ( 559 ) 268 -1172 Company Name: Mailing Address: Valuation of Project (contractor's bid price): $ 28,000.00 Scope of Work (please provide detailed information): New Panda Express Restaurant tenant improvement located at the northwest end cap of building North suite 108 within the Southcenter Square shopping center. The restaurant will serve gourmet Chinese food. City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Will service be altered? ❑ Yes ® No Adding more than 50 amps? ❑ Yes ® No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ® Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ® Puget Sound Energy ❑ Seattle City Light H:Wpplications\Ponns- Applications On Line4-2007 - Electrical Permit Application.doc bh State Zip Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: cr( Print Name: Colin Crawford Mailing Address: 4422 Francis Avenue W34 Date Application Expires: 4 Date Application Accepted: 10— t?--O7 H:1Applications\Fonns- Applications On Lia14-2007 - Electrical Penult Application.doc bh MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea Date: k ./ /te2 Day Telephone: (425) 957-4774 Seattle, WA 98103 City State Staff Initials: Zip Page 2 of 2 Parcel No.: Address: Suite No: Applicant: Receipt No.: R08 -00361 Initials: JEM User ID: 1165 Payee: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 - 3665 Web site: http: / /www.ci.tukwila.wa.us 2623049081 17100 SOUTHCENTER PY TUKW PANDA EXPRESS BOOCO CONSTRUCTION TRANSACTION LIST: Type Method Description Payment Cash ACCOUNT ITEM LIST: Description Account Code RECEIPT ELECTRICAL PERMIT - NONR 000.322.101.00.0 Amount 58.00 Current Pmts 58.00 Total: $58.00 Permit Number: Status: Applied Date: Issue Date: Payment Amount: $58.00 EL07 -582 ISSUED 10/12/2007 12/12/2007 Payment Date: 02/08/2008 12:41 PM Balance: $0.00 8400 02/11 9710 TOTAL 58.00 doc: Receiot -06 Printed: 02 -08 -2008 Receipt No.: R07 - 02743 Initials: JEM User ID: 1165 Payee: POLAR ELECTRIC LLC TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049081 Permit Number: ELO7 -582 Address: 17100 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 10/12/2007 Applicant: PANDA EXPRESS Issue Date: Amount Payment Check 5783 569.00 Account Code Current Pmts 000.322.101.00.0 433.70 000.345.832.00.0 135.30 Total: $569.00 Payment Amount: $569.00 Payment Date: 12/12/2007 11:46 AM Balance: $0.00 5948 12/12 9710 TOTAL 569.00 doc: Receiot -06 Printed: 12 -12 -2007 Parcel No.: 2623049081 Permit Number: EL07 -582 Address: 17100 SOUTECENTER PY TUICW Status: PENDING Suite No: Applied Date: 10/12/2007 Applicant: PANDA EXPRESS Issue Date: Receipt No.: R07 -02240 Initials: WER User ID: 1655 Payee: PANDA EXPRESS GROUP TRANSACTION LIST: Type Method Description Payment Check 672185 107.50 ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.cidukwila.wa.us RECEIPT Amount Account Code Current Pmts 000.322.101.00.0 107.50 Total: $107.50 Payment Amount: $107.50 Payment Date: 10/12/2007 12:18 PM Balance: $569.00 doc: Receipt -06 Printed: 10 -12 -2007 Project: � P/Vi /" E1 c Type of Inspection: � !� Address: / / vV S e.4,07/1 4/1, Date Called: Special Instructions: Date Wanted: 9� a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 8- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 OMMENTS: 0//- FiNfI L proved per applicable codes. Corrections required prior to approval. Insp�f /o 7 -522.. Date J A $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: !Date: Pr 'ect: flIA/44 £/PlYS Type of Inspection: 70 Address: par) xjf� Vo w/ Date Called: Special Instructions: ' Date Wanted: a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISI 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Ifto7•Cg`il PERMIT NO. ON (206)431 -36 0 El Approved per applicable codes. El Corrections required prior to approval. COMMENTS: r ir () /<-- (44(An G ✓4GL-j lns c / �G ...75/0.7_,___06744/0 I 7� $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Prolect: f 4>V/IncS Type of Inspection: 7P3 Address: / ?/C 5 ;VVI/TM Sy Date Called: Special Instructions: Date Wanted: / Requester: Phone No: 407- 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 MMENTS:(,4 CO/Z 1^ aroved per applicable codes. Corrections required prior to approval. I J lnspecr Date: / az.- - 4/Woi El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Project: P,A iv DA 1- Xl'Oc3 S Type of Inspection: I ?DV 3 Address: ) } 7 ) O O S t,T,,r,m, -,,.< Pr Date Called: , - // Special Instructions: Date Wanted: 0 7 -/y -eg a.m. p.m. Requester: "99 Phone No: _s of 9 H I, 1 lnspe tor: ieTP INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 E proved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: ' Date: PERMIT NO. (206)431 -367 $58.06 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Pro' oil Type of Inspection: Address: C / ? / ..W / y �.,� Date Called: / Special Instructions: Date Wanted: 77 a.m. Requester: Phone No: PERMIT NO. CITY OF TUKWILA BUILDING DIVISION f' 6300 Southcenter Blvd., #100, Tukwila, WA 98188- (206)431 -3670 COMMENTS: _7ov 3 J lnsp ec INSPECTION NO. proved per applicable codes. INSPECTION RECORD Retain a copy with permit It ❑ Corrections required prior to approval. Date x a/ $58.00 REINSPECTION FEE ,f El � EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project Info Project Address PANDA EXPRESS- SORTS CENTER MARKETPLACE Date 9/18/2007 17100 SOUTH CENTER PARKWAY For Building Department Use TUKWILA, WASHINGTON Applicant Name: VIGEN ARCHITECT Applicant Address: 1127 E. OLIVE AVENUE, FRESNO, CALIFORNIA 93728 Applicant Phone: 1 -559 -268 -2711 Project Description 1643.2 ❑ Plans Induded requirements. ❑ New Building ❑ Addition J Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option () Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive& LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) Occupancy Description Allowed Watts per ftZ " Area in ft Allowed x Area 1 -3.0 TYPE 'L17A': ROUND RECESSED FLUOR. W/ 15W. LAMP. FAST FOOD ESTABLISHMENT 1.30 1264.0 1643.2 TYPE 1 1,71 1 1 WALL MOUNTED 2 LAMP FLUORESCENT. 2 KITCHEN AND WORK ROOM IS EXEMPT PER 1512.1 ITEM #4. 160.0 13.0 TYPE 'L72's CEILING MOUNTED 2 LAMP FLUORESCENT. _ 2 38.0 76.0 13.0 TYPE .1.73's LOW VOLTAGE TRACK LIGHTING HEAD. 10 37.0 ** From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 1643.2 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed E3.0 TYPE 'L17A': ROUND RECESSED FLUOR. W/ 15W. LAMP. 21 16.0 336.0 E3.0 TYPE 1 1,71 1 1 WALL MOUNTED 2 LAMP FLUORESCENT. 2 80.0 160.0 13.0 TYPE 'L72's CEILING MOUNTED 2 LAMP FLUORESCENT. _ 2 38.0 76.0 13.0 TYPE .1.73's LOW VOLTAGE TRACK LIGHTING HEAD. 10 37.0 3 7 0 . 0 13.0 TYPE 'L73's SAME AS ABOVE. EIMPT. PER 1512.2 #6. 15 13.0 TYPE 'L74'sRECESSED INCANDESCENT DOWN LIGHT. 5 37.0 185.0 E3.0 9 37.0 333.0 TYPE 'L74A': RECESSED INCANDESCENT DOWN LIGHT. E3.0 TYPE ' L76 s SUSPENDED FLUORESCENT FIXTURE. 10 16.0 160.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 1620.0 Interior Lighting Summary LTG -INT 2008 Washington state Nonresidential Energy Code Compliance Forms Maximum Allowed Lighting Wattage Proposed Lighting Wattage 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 Notes: 1. For proposed Fixture Description, Indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and '• other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical 1 nual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blan OCT 12 1UU7 PERMIT CENTEFI Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations 1.0 Cafeterias, fast food establishments', restaurants/bars 1.3 Post office 1.1 Dormitory 1.0 Retail retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia assembly spaces 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel/motel 1.0 Warehouses ", storage areas 0.5 Hotel banquet/conference /exhibition hall .2.0 Workshops 1.4 Laboratory spaces (all spaces not classified laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: O Warehouses, storage areas or aircraft storage hangers °Other I Qualification Checklist Note: If occupancy type is ''Other and fixture answer Is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check If 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T-1, T -2, T-4, T -5, T-8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MI-I lamps <= 150w c) electronic ballasts 3. LED lights. 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 TABLE 15 -1 Unit Liahtln Power Allowance (LPA ootnotes for 1 able 15- 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be Increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Ught Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w/ft may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three- quarter - height partitions (transparent or opaque). and lighting for free- standing display where the lighting moves with the display are exempt. An additional 1.5 w/ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable In both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the Interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Lighting, Motor, and Transformer 2006 Washington State Nonresidential Energy Code Compliance Permit Plans Checklist Forms LTG -CHK Revised July 2007 Project Address PANDA EXPRESS- SOUTH CENTER >tc►axarri,nCE I Date 9/18/2007 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code I Section Component (Information Required Location I on Plans Building Department I Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations E3 -1 n.a. 1513.2 Area controls Maximum limit per switch 1513.3 Daylight zone control Schedule with type and features, indicate locations yes vertical glazing Indicate vertical glazing on plans E3 - 1 a.a. overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib /special Indicate separate controls E3 - 1 1513.5 Exterior shut -off Schedule with type and features, indicate location a. a. (a) timer w /backup Indicate location a. a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location n.a. 1513.6.1 (a) occup. sensors Schedule with type and locations I n.a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans yes 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes I 1514 (Max. watts 'Indicate watts for each exit sign I I LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) I 1511 'Elea motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I I TRANSFORMERS (Section 1540) I 1540 'Transformers 'Indicate size and efficiency I I 2006 Washington State Nonresidential Energy Code Compliance Form If "no" Is circled for any question, provide explanation: Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting In Section 1512. shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling - height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80%. A master control may be Installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either. a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power fora period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously Illuminated (e.g., 24 -hour convenience stores), or 2006 Washin on State Nonresidential Ener Code Corn • liance Form 2006 Washington State Nonresidential Energy Code Compliance Forms Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK Revised July 2007 Illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall - mounted, manual switch capable of turning off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position: 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off" feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5.000 ft or 5% of the building footprint for footprints over 100,000 ft whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP -1- 2002). October 24, 2007 Lupe Sandoval Vigen Architect 1127 E Olive Av Fresno CA 93728 RE: CORRECTION LETTER #1 Electrical Permit Application Number EL07 -582 Panda Express —17100 Southcenter Py, Ste 100 Dear Mr. Sandoval, If you have any questions, please contact me at (206) 433 -7165. xc: File No. EL07 -582 City of Tukwila P:\Permit Center\Correction Letters\2007\ELO7 -582 Correction Ltr #1.DOC jem Department of Community Development Steve Lancaster, Director This letter is to inform you of corrections that must be addressed before your electrical permit can be approved. All correction requests from the Building Department must be addressed and reflected on your drawings. Building Department: Bill Buterbaugh, at 206 973 -4758, if you have questions regarding the attached memo. Steven M. Mullet, Mayor Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that three (3) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Date: August 24, 2007 Project Name: Panda Express Permit #: E107- -582 Plan Reviewer: Bill Butetbaugh Building Division Review Memo 1. Circuit breakers as listed on the panel schedule do not comply with the requirements for the roof top units as listed in the mechanical schedule. 2. Panel designations will be: L -100 and L- 100-A. this complies with the usage throughout the complex. 3. Provide complete luminaire schedule. 4. Egress path requires 1 foot candle at floor along the entire pathway and egress discharge area. ACTIVITY NUMBER: EL07 -582 DATE: 01 -02 -08 PROJECT NAME: PANDA EXPRESS SITE ADDRESS: 17100 SOUTHCENTER PY, STE 100 Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPARTMENTS: A (�� j Bing D 'vision �,J Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1I Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route 4y Structural Review Required REVIEWER'S INITIALS: APPROVALS 0 CORRECTIONS: Documents/routing slip.doc 2 -28-02 , - PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete ❑ Planning Division Permit Coordinator DUE DATE: 01-03-08 No further Review Required DATE: DATE: Not Applicable ❑ DUE DATE: 01 -31-08 Approved Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: EL07 -582 DATE: 11 -06 -07 PROJECT NAME: PANDA EXPRESS SITE ADDRESS: 17100 SOUTHCENTER PY, STE 100 Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: p� c, . 2 8 Bt4i � n�visi `I 14 Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES/THURS ROUT G: Please Route Structural Review Required REVIEWER'S INITIALS: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documentshouting slip.doc 2-28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Fire Prevention Structural Incomplete ❑ DATE: DATE: Planning Division ❑ Permit Coordinator No further Review Required Et DUE DATE: 1 1-08-07 Not Applicable ❑ DUE DATE: 12-06-07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: EL07 -582 DATE: 10 -12 -07 PROJECT NAME: PANDA EXPRESS SITE ADDRESS: 17100 SOUTHCENTER PY - SUITE 100 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued a DEPARTMENTS: 114440 ng iv Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator X DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route APPROVALS OR CORRECTIONS: Documents/routing stip.doc 2 -28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Incomplete Structural Review Required DUE DATE: 10 -16 -07 Not Applicable ❑ No further Review Required REVIEWER'S INITIALS: DATE: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 11 -13 -07 Not Approved (attach comments) 1 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Date: da 'V Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the malt fax, etc. E l Response to Incomplete Letter # ❑ Response to Correction Letter # RECEIVED Revision # ( after Permit is Issued Clry Or T ❑ Revision requested by a City Building Inspector or Plans Examiner JAN - 2 2008 Project Name: i 4 # H-- a ift t 'y e__s g Project Address: ` Pr!%2 J /A-0 Contact Person: Li-, /° e— Phone Number: — 2_4-Y— 7- 71/ Summary of Revis o n: o £4 - iE O p L, 9 -\ , D 04-4 daer ' � .� 7 �� /2_, As ��L 13��c� yr iic tin., rA- f c Sheet Number(s): "Cloud" or highlight all areas of revision including date of r ' ision Received at the City of Tukwila Permit Center Entered in Permits Plus on Created: 8 -13 -2004 Rwiwrl• City of Tukwila a applicationslfomu- applications on line\Cevision submittal Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us `r Plan Check/Permit Number: F L- 6? Steven M. Mullet, Mayor Steve Lancaster, Director W11 /N•. (.cNTEh i City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted In person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: EL07 -582 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Panda Express Project Address: 17100 Southcenter Py, Ste 100 Contact Person: Summary of Revision: \applications\forms - applications on line\revision submittal Created: 8 -13 -2004 Revised: 1-4JPE SAC POr AL_ Phone Number: CSSq) Z 8— 27 I ( pesp t.. e-r-re - A - {TPOprep REV I s t e Jc . Steven M. Mullet, Mayor Steve Lancaster, Director wicw/L NOV 07 2007 ''ENM17 CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on City of Tukwila Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 Phone (206) 431 -3670 Re: The Proposed Panda Express Restaurant 17100 Southcenter Parkway, Suite 100 Electrical Permit 1 Submittal Job Address: 17100 Southcenter Parkway, Suite 100 Description: New Tenant improvement Building Occupancy. Use Group A2 Construction: Ill B Hoerner Vigen Comm. # H702.020 Panda Express' Site # S4 -08 -1677 Att: Bill Buterbaugh Plans Examiner Comments 1. See revised panel schedules Sheet E -5.0. 2. See Panels designations Sheet E -5.0. 3. See lighting fixture schedule added to Sheet E -3.0. 4. See note added to Sheets A - 1.0, A - 1.1, and E - 3.0. End of Responses If you have questions or need further clarification regarding the items responded above, please feel free to contact me at (559) 268 -2711. Sincerely, Lupe Sandoval Project Manager Cc: Jerald Earl Panda Express Architecture & Planning 1127 East Olive Avenue Fresno. CA 93728 -3534 Voice: 559.268.2711 Fax: 559.268.1172 Business Owner Information Name Role Effective Date Expiration Date DORE', GREGORY PARTNER/MEMBER 08/11/2003 DORE', ANTHONY PARTNER/MEMBER 08/11/2003 DORE', ROBYN PARTNER/MEMBER 08/11/2003 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries Electrical Contractor A business licensed by L&I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License Licensee Name Licensee Type UBI Ind. Ins. Account Id Business Type Address 1 Address 2 City County State Zip Phone Status Specialty 1 Specialty 2 Effective Date Expiration Date Suspend Date Separation Date Parent Company Previous License Next License Associated License POLAREL974NJ POLAR ELECTRIC LLC ELECTRICAL CONTRACTOR 602317730 LIMITED LIABILITY COMPANY PO BOX 854 REPUBLIC FERRY WA 99166 5097750907 ACTIVE GENERAL UNUSED 8/11/2003 8/11/2009 DORE *GJO55RB Electrical Administrator Information License Name Status DORE *GJO55RB DORE', GREG J ACTIVE https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= POLAREL974NJ 12/12/2007 ELECTRICAL LEGEND LIGHTING 0 DOWNUGHT Q WALL MOUNTED FLUORESCENT OR INCANDESCENT LUMINAIRE, AS NOTED MOM H I FLUORESCENT STRIP LUMINAIRE OJ ' TRACK LIGHT, AS NOTED OR SCHEDULED <0 DIRECTIONAL ACCENT OR WALL-WASH LUMINAIRE ❑ C ❑ EXTERIOR POLE MOUNTED LUMINAIRE, AS SCHEDULED ❑ BOLLARD ei CEILING OR WALL MOUNTED EXIT SIGN, INSTALL FACES AS INDICATED BY SHADING ` EMERGENCY UGHT AS NOTED AS NOTED POWER STRAIGHT BLADE DUPLEX RECEPTACLE SUBSCRIPTS: HG = HOSPITAL GRADE HGT = HOSPITAL GRADE TAMPER RESISTANT GFI = GROUND FAULT INTERRUPTER SS = SURGE SUPRRESSION AC = 6" ABOVE COUNTER STRAIGHT BLADE DOUBLE DUPLEX RECEPT. (FOURPLEX) 0- STRAIGHT BLADE SINGLE RECEPTACLE STRAIGHT BLADE DUPLEX RECEPT. HALF - SWITCHED STRAIGHT BLADE DUPLEX RECEPT. ON EMERGENCY CIRCUIT ® OUTLET WITH SPECIAL DEVICE, AS NOTED 0 WALL MOUNTED OUTLET WITH SPECIAL DEVICE, AS NOTED ®o J Q-I IDI I] IPB EXP A I MCC I I ss T CEILING OR WALL MOUNTED HID LUMINAIRE PORCELAIN KEYLESS SURFACE MOUNTED FLUORESCENT LUMINAIRE RECESS MOUNTED FLUORESCENT LUMINAIRE RECESS MOUNTED FLUORESCENT LUMINAIRE WITH MODULAR WIRING CONNECTOR FLOOR MOUNTED POWER BOX, AS NOTED FLOOR MOUNTED COMBINATION OUTLET BOX, AS NOTED POKE THROUGH, AS NOTED PEDESTAL OUTLET, AS NOTED JUNCTION BOX AS NOTED OUTLET BOX WALL MOUNTED OUTLET BOX ABOVE CEILING POWER DISTRIBUTION BOX SURFACE RACEWAY, AS NOTED CLOCK HANGER OUTLET TELE -POWER POLE PULL BOX CONNECTION TO MOTOR MAGNETIC MOTOR STARTER SUBSCRIPTS: MS = MULTISPEED SSRV = SOLID- STATE, REDUCED VOLTAGE VF = VARIABLE FREQUENCY SAFETY DISCONNECT SWITCH FUSED DISCONNECT SWITCH COMBINATION DISCONNECT AND STARTER ENCLOSED CIRCUIT BREAKER, MOLDED -CASE, THERMAL- MAGNETIC SUBSCRIPTS: AT = ADJUSTABLE TRIP EAT = ELECTRONIC ADJUSTABLE TRIP CL = CURRENT LIMITING IF = INTEGRALLY FUSED GFCI = GROUND FAULT CIRCUIT INTERRUPTER ST KI ZSI WALL MOUNTED SWITCH = SHUNT TRIP = KEY INTERLOCK = ZONE---SELECTIVE INTERLOCKING CONNECTION TO PRE -WIRED EQUIPMENT BREAKER PANEL MOTOR CONTROL CENTER TRANSIENT VOLTAGE SURGE SUPPRESSOR TRANSFORMER ENGINE GENERATOR CIRCUITING CONDUIT RUN -ow-IN- CIRCUIT HOMERUN TO PANEL OR CABINET, NO. OF ARROWS INDICATE NO. OF CIRCUITS CIRCUIT TURNED UP CIRCUIT TURNED DOWN CONDUIT STUB -OUT - CAP & MARK CIRCUIT IN FLEXIBLE CONDUIT SEALOFF SWITCHING S SUBSCRIPTS: 2 = DOUBLE POLE 3 = 3 -WAY 4 = 4-WAY D = DIMMER K = KEY - OPERATED 0 = SWITCH MOUNTED OCCUPANCY SENSOR P = PILOT UGHT T = THERMAL OVERLOAD LV = LOW VOLTAGE DS = DOOR SWITCH NOTE: ALL SYMBOLS SHOWN ON LEGEND ARE NOT NECESSARILY USED. SCHEMATIC WIRING GRAPHICS GROUND FAULT PROTECTION GENERATOR MOTOR, NUMBER INDICATES HORSEPOWER FIRE ALARM SYSTEM IFACPI FIRE ALARM CONTROL PANEL FIRE ALARM GRAPHIC PANEL FIRE ALARM ANNUNCIATOR PANEL MANUAL PULL STATION FIRE ALARM STROBE GENERAL ALARM COMBINATION HORN /STROBE FIRE ALARM HORN ® 0 CEILING OR WALL MOUNTED DETECTOR SUBSCRIPTS: I = IONIZATION T = THERMAL, FIXED AND RATE -OF -RISE IF = THERMAL, FIXED T165* = 165'F THERMAL, FIXED AND RATE -OF -RISE TF165' = 1651= THERMAL, FIXED P = PHOTOELECTRIC PT = COMBINATION PHOTOELECTRIC AND THERMAL OF SMOKE DETECTOR IN VENTILATING DUCT FAN SHUT -DOWN CONNECTION O MAG. DOOR HOLDER CD SPRINKLER SYSTEM FLOW SWITCH CD SPRINKLER SYSTEM TAMPER SWITCH IFAGPI IFAAPI FIREFIGHTERS TELEPHONE JACK LIFE SAFETY SPEAKER LIFE SAFETY SPEAKER WITH STROBE P 0 - 1 REMOTE PILOT LIGHT O REMOTE PILOT LIGHT WITH TEST SWITCH P/T 0 , MONITOR MODULE CONTROL MODULE DAMPER CONNECTION COMMUNICATION SYSTEM ® FLOOR MOUNTED TELEPHONE AND /OR DATA OUTLET BOX, AS NOTED ✓ WALL MOUNTED TELEPHONE OUTLET ✓ WALL MOUNTED DATA OUTLET ✓ WALL MOUNTED COMBINATION TELEPHONE /DATA OUTLET BOX P 0" PAY PHONE 1 TELEPHONE TERMINAL BOARD - TTB Q 0-1 CEILING OR WALL MOUNTED SPEAKER �V -I VOLUME CONTROL ‹"Q} FLOOR OR WALL MOUNTED MICROPHONE OUTLET 0 CALL -IN SWITCH TIME --TONE UNIT POWER TRANSFORMER CURRENT TRANSFORMER AMMETER VOLT METER TRANSFER SWITCH METER GROUND CONNECTION AS NOTED FUSED DISCONNECT SWITCH FUSES MAGNETIC MOTOR STARTER SUBSCRIPTS: MS = MULTISPEED SSRV = SOLID - STATE, REDUCED VOLTAGE VF = VARIABLE FREQUENCY ENCLOSED CIRCUIT BREAKER, MOLDED -CASE, THERMAL -- MAGNETIC SUBSCRIPTS: AT = ADJUSTABLE TRIP EAT = ELECTRONIC ADJUSTABLE TRIP CL = CURRENT LIMITING IF = INTEGRALLY FUSED GFCI = GROUND FAULT CIRCUIT INTERRUPTER ST = SHUNT TRIP KI = KEY INTERLOCK ZSI = ZONE - SELECTIVE INTERLOCKING O 0 CEIUNG OR WALL MOUNTED CLOCK QB -I PROGRAM BELL B BUZZER O HOUSE PHONE /INTERCOM 0 M MASTER INTERCOM STATION TV-1 TELEVISION ANTENNA OUTLET CLOSED CIRCUIT TV OUTLET H AMPLIFIER NOTATIONS 1 - UPPER CASE LETTER AT LUMINAIRES (F1, I1 , ETC.) INDICATES LUMINAIRE TYPE. F7 = TYPE Fl LUMINAIRES IN AREA INDICATED. 2 - LOWER CASE LETTER AT LUMINAIRES AND SWITCHES (a, b, ETC.) INDICATE ASSOCIATED UNITS FOR SWITCHING. 3 - SHADING WITHIN LUMINAIRE DENOTES UNIT ON EMERGENCY (EM) CIRCUIT. 4 - "NL" WITHIN LUMINAIRES DENOTES UNIT ON NIGHT LIGHT CIRCUIT. 5 - PLUS (+) SIGN WITH DIMENSION AT OUTLET INDICATES HEIGHT ABOVE FINISHED FLOOR OR GRADE TO CENTERLINE OF OUTLET. ABBREVIATIONS NOTE: ALL ABBREVIATIONS SHOWN ARE NOT NECESSARILY USED. AC AFC AFF AFG AIC AL BFG CB CR CPT CT CU ELR EM ES ETM EWC FLA FVNR FVR FWE GFI GRC HOA HP IG LC LOR LS LT MCA MCB MCC MCCB MCP MLO NC NIC NL NO NTS OC OL PT RVNR SC SR TTB UG VFD WG WP XFMR XP ZS - ABOVE COUNTER - ABOVE FINISHED CEILING - ABOVE FINISHED FLOOR - ABOVE FINISHED GRADE - AMPS INTERRUPTING CURRENT - ALUMINUM - BELOW FINISHED GRADE - CIRCUIT BREAKER - CORROSION RESISTANT - CONTROL POWER TRANSFORMER - CURRENT TRANSFORMER - COPPER - END OF LINE RESISTOR - EMERGENCY - EMERGENCY STOP - ELAPSED TIME METER - ELECTRIC WATER COOLER - FULL LOAD AMPS - FULL VOLTAGE, NON - REVERSING - FULL VOLTAGE, REVERSING - FURNISHED WITH EQUIPMENT - GROUND FAULT INTERRUPTER - GALVANIZED RIGID CONDUIT - HAND - OFF - AUTOMATIC - HORSEPOWER - ISOLATED GROUND - LIGHTING CONTACTOR - LOCAL- OFF - REMOTE - LEVEL SWITCH - LET THROUGH - MINIMUM CIRCUIT AMPS - MAIN CIRCUIT BREAKER - MOTOR CONTROL CENTER - MOLDED CASE CIRCUIT BREAKER - MOTOR CIRCUIT PROTECTION - MAIN LUGS ONLY - NORMALLY CLOSED - NOT IN CONTRACT - NIGHT UGHT - NORMALLY OPEN - NOT TO SCALE - OVER CURRENT - OVERLOAD - POTENTIAL TRANSFORMER - REDUCED VOLTAGE, NON - REVERSING - SHORT CIRCUIT - SAFE OR STOP /RUN - TELEPHONE TERMINAL BOARD - UNDERGROUND - VARIABLE FREQUENCY DRIVE - WIREGUARD - WEATHERPROOF - TRANSFORMER - EXPLOSION PROOF - LIMIT OR POSITION SWITCH THESE DRAWINGS ARE DIAGRAMMATIC - REFER TO ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS. BRANCH CIRCUITING CONVENTION - #12 AWG PER PHASE AND NEUTRAL (WHERE REQUIRED) AND 20 AMPERE CIRCUIT BREAKER, UNLESS OTHERWISE NOTED. PROVIDE QUANTITY AND SIZE SWITCH CONDUCTORS AS REQUIRED TO MAKE SYSTEM OPERATIONAL tRE\1 S10N S sGOP g shallbemade to the c X o oha� without prior Division rov of w ork submittal Tok�aila Building a new plan NOTE may Revisions wi11 require 1ari revie ... . and may include additional plan NOTES (FOR ALL ELECTRICAL SHEETS) 1. COORDINATE LOCATION OF LUMINAIRES WITH ARCHITECTURAL REFLECTED CEILING PLANS. 2. 3 AND 4 LAMP FIXTURES SHOWN HALF SHADED SHALL HAVE INBOARD LAMP CONNECTED TO EMERGENCY BAI ILRY PACK. SEE SPECIFICATIONS. 3. PLANS DO NOT INDICATE ALL OF THE UG UTILITY UNES. CONTRACTOR TO FIELD VERIFY EXACT LOCATION OF ALL EXISTING UNDERGROUND UTILITY UNES OF ALL TRADES PRIOR TO ANY SITE WORK. 4. PROVIDE (1) 3/4 "C. WITH PULL WIRE FROM EACH TELEPHONE, DATA OR COMMUNICATION OUTLET SHOWN, TO TELCO DEMARC LOCATION, AND CAP. (UNLESS SPECIFIED OTHERWISE ON PLANS). 5. COORDINATE EXACT EQUIPMENT LOCATIONS WITH OWNER PRIOR TO ROUGH -INS. 6. COORDINATE LOCATION OF ALL OUTLETS WITH ARCHITECTURAL ELEVATIONS, CASEWORK SHOP DRAWINGS AND EQUIPMENT INSTALLATION DRAWINGS. 7. COORDINATE LOCATION OF MECHANICAL EQUIPMENT WITH MECHANICAL PLANS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH -IN. 8. ANY ITEMS DAMAGED BY THE CONTRACTOR SHALL BE REPLACED BY THE CONTRACTOR. 9. ALL 120V BRANCH CIRCUITS SHALL BE 3 -WIRE (PHASE,NEUTRAL,GROUND). 10. CONTRACTOR SHALL NOT ROUTE ANY CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS NOTED TO DO SO. 11. REFER TO ARCHITECTURAL PLANS, ELEVATIONS AND DIAGRAMS FOR LOCATIONS OF FLOOR DEVICES AND WALL DEVICES. LOCATION WILL INDICATE VERTICAL AND/ OR HORIZONTAL MOUNTING. IF DEVICES ARE NOT NOTED OTHERWISE THEY SHALL BE MOUNTED LONG AXIS VERTICAL AT +16" TO CENTER. 12. INFORMATION ON THE DRAWINGS HAS BEEN ASCERTAINED FROM CONCEPTUAL PLAN DRAWINGS AND INFORMATION PROVIDED BY OTHERS. THIS INFORMATION IS AS ACCURATE AS CONDITIONS WOULD ALLOW. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE SITE, PRIOR TO BID, AND FAMILIARIZE HIMSELF WITH THE EXTENT OF REMODEL WORK REQUIRED. NO EXTRAS WILL BE ALLOWED FOR ALTERATIONS OF A FORESEEABLE NATURE REQUIRED TO ACHIEVE THE END RESULT AS INDICATED BY CONTRACT DOCUMENTS. 13. ALL FINAL CONNECTIONS TO OWNER FURISHED EQUIPMENT SHALL BE MADE BY THE CONTRACTOR, UNLESS OTHERWISE NOTED. VERIFY ALL ELECTRICAL REQUIREMENTS AND U.L. LISTING WITH OWNER AND EQUIPMENT SUPPUER PRIOR TO CONNECTION. 14. PAINT ALL EXPOSED ELECTRICAL RACEWAYS, CABINETS, ENCLOSURES, AND FITTINGS TO MATCH IN COLOR ADJACENT SURFACES IN ALL FINISHED AREAS. 15. BRANCH CONTROL CIRCUITING AND WIRE COUNT MAY NOT BE INDICATED ON PLANS. CONTRACTOR IS RESPONSIBLE TO PROVIDE COMPLETE AND OPERATIONAL SYSTEMS AND CIRCUITS FOR ALL SYSTEMS SHOWN. 16. ALL EQUIPMENT SHOWN IS NEW, CONTRACTOR FURNISHED AND INSTALLED, UNLESS OTHERWISE NOTED. IF CONTRACTOR PROPOSES TO SUSTITUTE ANY EQUIPMENT SPECIFIED, CONTRACTOR SHALL SUBMIT REQUEST FOR APPROVAL TO THE OWNER AND ENGINEER PRIOR TO BID IN WRITING. ALL SUBST1T1oNS MUST BE REVIEWED BY THE ENGINEER. SUCH REVIEW SHALL NOT RELIEVE THE CONTRACTOR FROM COMPLYING WITH THE REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE, AT HIS OWN EXPENSE, FOR ANY CHANGE RESULTING FROM HIS PROPOSED SUBSTITIONS WHICH AFFECT OTHER PARTS OF HIS OWN WORK OR SUBSTITUTIONS WHICH AFFECT OTHER PARTS OF HIS WORK OR THE WORK OF OTHER CONTRACTORS. 17. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY TYPES OF CEIUNG SYSTEM AND TO FURNISH APPROVED LIGHTING FIXTURES OF THE TYPE REQUIRED FOR MOUNTING IN RELATED CEILINGS. FIXTURES SHALL BE COMPLETED WITH NECESSARY MOUNTING HARDWARE AND ACCESSORIES. FIXTURES LOCATED IN DAMP OR WET LOCATIONS SHALL BE LABELED FOR USE IN SUCH LOCATIONS. 18. PORTIONS OF THE CEILING SYSTEM MAY BE INACCESSIBLE THEREFORE, THE CONTRACTOR SHALL STRATEGICALLY LOCATE ACCESS BOXES, ETC., WHICH SHALL BE READILY ACCESSIBLE. ALL LIGHTING FIXTURE WIRING, BALLASTS, J- BOXES, ETC. SHALL BE ACCESSIBLE FROM FIXTURE OPENING. 19. SEAL ALL PENETRATIONS AND MAINTAIN ALL FIRE RATINGS. FURNISH AND INSTALL FIRE RATED ENCLOSURES FOR ANY EQUIPMENT WHICH PENTRATES INTO ANY FIRE RATED ENVELOPS, SPACES ETC. APPROVED P: , �;�T �� r;rlC/' 1 7P!" ?fib ".r. . VT" -;' ":LIED, MODIFIED CR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING O7"IC :AI , AL I WORK SMALL. BE DONE IN ACCORDANCE WITH THE APPROVED P($ r 5 !3�:::T TO FIFF. _D INSPECTIOPI3 RECEIVED CITv OFTUKWILA I JAN - 2 2008 FILE COP FILE COPY Permit No. Mar review Approval of the violet) of approv By Dat Is subject to errors end omissions. clion documents does not authorize code or b» ReceiPt and coons Is admowledged: City of Tukwila BUILDING DIVISION Public Works, Building Division PERMIT NUMBER REVISION Nil_ PANDA RESTAURANT GROUP, INC. Contact Person: Jerald Earl 1683 WALNUT GROVE AVE. ROSEMEAD, CALIFORNIA 91770 Direct: 360.885.1 135 Telephone: 626.714.8971 Facsimile: 626.372.8310 PROPERTY OWNER: WIG PROPERTIES LLC -SS 4811 134TH PL SE BELLEVUE, WA 98006 THESE DRAWINGS. DESIGNS, SKETCHES. IDEAS. ARRANGEMENTS AS WELL AS ANY AND ALL ELECTRONIC FILES AND /OR DWGS ARE THE SOLE AND EXCLUSIVE PROPERTY OF PANDA RESTAURANT GROUP INC. & VIGEN ARCHITECT. THESE PLANS WERE CREATED AND DEVELOPED BY AND FOR THE ARCHITECT'S WORK. NOTHING CONTAINED OR REPRESENTED ON THESE DOCUMENTS SHALL BE USED BY OR DISCLOSED TO ANY PERSON. FIRM OR CORPORATION FOR ANY PURPOSE WITHOUT THE EXPRESSED WRIT TEN CONSENT OF PANDA RE T 1JRANT GROUP. INC. & VIGEN ARCHITECT THE WORK CONTAINED ON THESE DWGS AND DOCUMENTS IS CREATED ONLY FOR THIS PROJECT AT THIS TIME AND NO OTHER. AND NOT FOR OTHER RELATED. IMPLIED. OR FUTURE WORKS) OR PROJECT(S), • REVISIONS: • REV. A A A A A A A DATE • ISSUE DATE: • 1ST 2ND 3RD 4TH 5TH i ARCHITECT IN VIGEN • PROJECT: • DESCRIPTION BY ARCHITECT A R C H I T E C T U R E& P L A N N I N G 1127 E. Olive Avenue Fresno, CA 93728 Phone: 559.268.2711 Fax: 559.268.1172 Web: www.vigen.com PANDA EXPRESS "SOUTHCENTER MARKETPLACE" 17100 SOUTH CENTER PARKWAY TUKWILA, WA PANDA PROJECT #: ARCH PROJECT #: H702.020 DATE #: 8/25/07 THESE DRAWINGS TO BE USED ONLY FOR THE PROJECT LOCATED ABOVE. II SEAL: • /FIMA.N VIGEN OF WASHINGTON S4-08-D167 SHEET NO. E -1.0 ELECTRICAL SYMBOLS, LEGEND, AND GENERAL NOTES ADDENDUM SUBMITTAL 1 2/1 8/07 ELECTRICAL NOTES THIS SHEET: g) 0 PROVIDE JUNCTION BOX AND RECEPTACLES AS SHOWN IN STAINLESS STEEL OUTLET PANEL DETAIL, SHEET E -4.0, TOP HEIGHT MIN. 12". WATER PROOFING REQUIRED. 0 0 0 10 11 13 14 15 16 17 18 19 21 ALL CONDUIT SHALL BE ROUTED WITHIN CASEWORK FOR FRONT LINE EQUIPMENT OVER TO WALL, AND UP WITHIN WALL CONCEALED, TO ABOVE CEILING LEVER PRIOR TO ROUTING TO PANELS. PROVIDE CONDUIT STUB OUT ONLY PRIOR TO CASE INSTALLATION. PROVIDE TWO – CHANNEL TIME CLOCK AND LIGHTING CONTACTORS LC -1 AND LC -2 ADJACENT TO PANELS FOR CONTROL OF EXTERIOR LIGHTING CIRCUITS. SEE LIGHTING NOTE #6, SHEET E -3.0. PROVIDE CONNECTION TO FRYER(S) VIA HOOD CONTROL BOX. SEE COOKING EQUIPMENT EMERGENCY SHUT –OFF WRING DIAGRAM, SHEET E -4.0. PROVIDE DUPLEX RECEPTACLES ABOVE WINDOW LOCATIONS SHOWN FOR FUTURE CONNECTION TO WINDOW SIGNAGE. FIELD VERIFY FINAL LOCATIONS OF ALL SIGNAGE WITH ARCHITECT AND OWNER PRIOR TO ROUGH –IN. CIRCUIT VIA LIGHTING CONTRACTOR (LC -2) (AND THUS TIMECLOCK (TC -2)) (NOTE # 4, THIS SHEET). *NOTE: PROVIDE DEDICATED NEUTRAL CONDUCTOR TO EACH SIGN. PROVIDE ELECTRICAL CONNECTION TO GAS FIRED WATER HEATER (IGNITION). VERIFY EXACT LOCATION WITH PLUMBING PLANS AND PLUMBING CONTRACTOR. PROVIDE RECESS PULL BOX AT 44" ABOVE FLOOR ON NEAREST ACCESSIBLE WALL CLOSEST TO POINT SHOWN FOR CONNECTION TO ANSUL PULL STATION. SEE ANSUL PULL STATION DETAIL, SHEET E -4.0. ALL 15 AMP AND 20 AMP RECEPTACLES IN KITCHEN SHALL BE CFI PROTECTED. SEE MGR STATION ELEVATION, SHEET E -4.0. PROVIDE SHUNT TRIP CIRCUIT BREAKER FOR ANY EQUIPMENT LOCATED UNDER HOOD. SEE LOW VOLTAGE PLAN, SHEET LV -1, FOR PHONE AND DATA CONDUIT ROUTING AND JACK LOCATIONS / TYPE. COMPUTER AND CASH REGISTER STATION COMBINATIONS (81 & 86A) SHALL BE CIRCUITED ON SAME CIRCUIT W/ ISOLATED GROUND PULLED. RECEPTACLES SHALL BE ORANGE. ELECTRICAL SERVICE AND PANELS INSTALLED UNDER SHELL CONSTRUCTION. COORDINATE WITH SHELL CONTRACTOR. SEE ELECTRICAL RISER DIAGRAM, SHEET E -4.0. HOOD CONTROL PANEL. VERIFY EXACT LOCATION WITH OWNER, HOOD SUPPLIER, AND MECHANICAL CONTRACTOR PRIOR TO ROUGH –IN. SEE KITCHEN EXHAUST SYSTEM DIAGRAM, SHEET E -4.0. INTERIOR SIGNAGE (MENU BOARD AND BEVERAGE SIGN) TO BE SWITCHED VIA SWITCHBANK. SEE SWITCHBANK DETAIL, SHEET E -3.0. SEE LIGHTING PLAN, SHEET E -3.0. CIRCUIT SHOW WINDOW RECEPTACLE(s) VIA SWITCH FOR CONTROL OF WINDOW SIGNAGE AS DIRECTED BY OWNER. VERIFY EXACT LOCATION OF SWITCHED RECEPTACLE (WHICH WINDOW(s)) PRIOR TO ROUGH –IN. SEE SWITCHBANK DETAIL, SHEET E -3.0. 4' x 4' TELCO BACKBOARD WITH QUADRAPLEX OUTLET PROVIDED DURING SHELL CONSTRUCTION. COORDINATE LOCATION WITH OWNER AND SHELL CONTRACTOR. SEE TELEPHONE BACKBOARD DETAIL, THIS SHEET. CONTRACTOR TO FIELD LOCATE TIMECLOCK (TC -1) AND LIGHTING CONTACTORS (LC -1 & LC -2) IN AREA SHOWN. MAINTAIN ALL CLEARANCES AS PER NEC. CIRCUITS FOR EXTERIOR BUILDING MOUNTED SIGNAGE AND EXTERIOR GFI RECEPTACLES TO BE INSTALL DURING SHELL CONSTRUCTION. COORDINATE LOCATIONS WITH OWNER AND SHELL CONTRACTOR. GENERAL NOTES, THIS SHEET: 1. VERIFY WITH EQUIPMENT SUPPLIER AND OWNER (PANDA) THAT KITCHEN EQUIPMENT SHOWN WILL BE EQUIPMENT SUPPLIED PRIOR TO ROUGH –IN. 2. VERIFY MECHANICAL EQUIPMENT LOCATION AND INSTALLATION REQUIREMENTS WITH MECHANICAL CONTRACTOR. 4' 3/4 NORMAL USE QJ QUAD RECEPTACLE 4' 4' x 4' x 3/4" PLYWOOD TELEPHONE BACKBOARD TELEPHONE BACKBOARD DETAIL NO SCALE ( —TELEPHONE SERVICE ENTRANCE CONDUIT AND CABLES +132" I I I I I I I I I I I I I L J, -J L- B -30 j,... e ...... 9 ,... f 24' (4#12-4120)1/2"C B– (11,13,15) 3 "95 ELEC. STUB UP SOFFIT LINE ABOVE (3#12+#12G)1/ A–(14,16,18) (3 #12 + #12G)1/2 "C A- (2,4,6) r I SEE DETAILS 9 & 13/A3.0 FOR T –BAR CEILING DETAILS. 2 B -38 B_23 B -21 21 O B -10,12 8 1 t J B -10,12 J � REFLECTED CEILING PLAN SCALE: 1/4"— 1 0 N 0 2 4 16 REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC JAN 1 6 2008 City Of Tukwila BUILDING DIVISION RECEIVED are OF TUKWILA JAN 2 2000 PANDA RESTAURANT GROUP, INC. Contact Person: Jerald Earl 1683 WALNUT GROVE AVE. ROSEMEAD, CALIFORNIA 91770 Direct: 360.885.1 135 Telephone: 626714.8971 Facsimile: 626.372.8310 PROPERTY OWNER: WIG PROPERTIES LLC -SS 4811 134TH PL SE BELLEVUE, WA 98006 THESE DRAWINGS. DESIGNS. SKETCHES. IDEAS. ARRANGEMENTS AS WELL AS ANY AND ALL ELECTRONIC FILES AND /OR DWGS ARE THE SOLE AND EXCLUSIVE PROPERTY OF PANDA RESTAURANT GROUP INC. & VIGEN ARCHITECT. THESE PLANS WERE CREATED AND DEVELOPED BY AND FOR THE ARCHITECT'S WORK. NOTHING CONTAINED OR REPRESENTED ON THESE DOCUMENTS SHALL BE USED BY OR DISCLOSED TO ANY PERSON. FIRM OR CORPORATION FOR ANY PURPOSE WITHOUT THE EXPRESSED WRITTEN CONSENT OF PANDA RESTAURANT GROUP. INC. & VIGFN ARCHITECT. THE WORK CONTAINED ON THESE DWGS AND DOCUMENTS IS CREATED ONLY FOR THIS PROJECT AT THIS TIME AND NO OTHER. AND NOT FOR OTHER RELATED. IMPLIED. OR FUTURE WORK(S) OR PROJFCT(S). • REVISIONS: • REV. A A A A A 1ST 2ND 3RD 4TH 5TH DATE 10/31/07 11/09/07 • SEAL: • DESCRIPTION BY PLAN CHECK PRG CHANGES • ISSUE DATE: • • ARCHITECT • VIGEN • PROJECT: ■ ARCHITECT A R C H I T E C T U R E& P L A N N I N G 1127 E. Olive Avenue Fresno, CA 93728 Phone: 559.268.2711 Fax: 559.268.1172 Web: www.vigen.com PANDA EXPRESS "SOUTHCENTER MARKETPLACE" 17100 SOUTH CENTER PARKWAY TUKWILA, WA PANDA PROJECT #: S4- 08-D167 ARCH PROJECT #: H702.020 DATE #: 8/25/07 THESE DRAWINGS TO BE USED ONLY FOR THE PROJECT LOCATED ABOVE. REGIS° D ARCHTTECT ti y I / t '' 1 I GARY TIMAN VIGEN SI TE OR�'ANASIIINGTON ELECTRICAL LIGHTING PLAN AND LIGHTING NOTES ADDENDUM SUBMITTAL 12/18/07 ■ MH MH EQUIPMENT SCHEDULE S4-08-D1677 08/29/07 KEY PLUMBING ELECTRICAL DESCRIPTION FEEDER FS INDIRECT CONNECTION TO FLOOR SINK D DIRECT CONNECTION 0 OWNER(PANDA EXPRESS, INC.) S SERVING AREA DISC. D DIRECT CONNECTION C CONVENIENT OUTLET GC GENERAL CONTRACTOR K KITCHEN (3 #6 + #10G) 1"C RIH ROUGH IN HEIGHT (TO CENTER OF CONNECTION) FS FLOOR STUB OUT EC ELECTRICAL CONTRACTOR (E) EXISTING DC DROPPED CORD KEC KITCHEN EQUIPMENT CONTRACTOR SUPPLY BY GAS WASTE COLD WATER HOT WATER CONNECTION LOAD PHASE H.P. VOLTS REMARKS DIMENSIONS MANUFACTURE MODEL # EQUIPMENT NO. K BTU R.I.H. SIZE TYPE SIZE R.I.H. SIZE R.I.H. SIZE R.I.H. TYPE WATT -- 60A 3P 1. W x D x H (o x H) kVA SERVING AREA EQUIPMENT NEMA 3R 2. SF -1 KITCHEN HOOD 3 208 -3 (3 #12 + #12G) 3/4"C * 20" 1 /2" 1. (SUPPLY FAN) HP SEE DETAIL 5EE PLAN KEC CUSTOM SERVICE COUNTER I 1 208 -3 (3#12 + #12G) 3/4 "C * -- 30A 3P 1. HP 24" F 1500W 1 NEMA 3R 115 SEE DETAIL SEE PLAN KEC CUSTOM SNEEZE GUARD 2 -- 30A 3P 1. FS 1/2 " - 1" 24' F 3600W 3 1/4 208 (2 #12 + #12G) 1/2"C 43 1/2 ° x23 1/2" APW HFW -3 3 PAN FOOD WARMER 3C HP FS 1/2 " -1" SWITCH 32 WALK -IN FREEZER (REMOTE CONDENSOR) 24" F 4800W 3 20A 208 3. 57 3/4 ° x23 1/2 APW HFW -4 4 -PAN FOOD WARMER (2) 3D * 20A 30A 2P NEMA 3R 3. FS 3/4" 2.4 kVA 208 -1 (2 #10 + #10G) 3/4 "C * 15A 30A 2P NEMA 3R 3. 115 W /UD DISPENSER 30 "x30 ° x35" CORNEUUS ED -2000 BEVERAGE DISPENSER 4AB 1/2" 16" C 1.5A 1 115 ON S/S SHELF 15 "x11 "X16" CORNEUUS CARBONATOR 4B 96" C 7.2A 1 29 ° x18" CORNEUUS SODA RACK 4C ON 6' CURB 020" CO2 TANK 4D SEE ELEV. DWG 24"x18 KEC CARBONATOR SHELF 4E 96" 1 /2" WALL MOUNT 20"x4 "x20" EVERPURE WATER FILTER 4F FS 1 /2" 24 "x24 "x6 1/2" KEC CUSTOM 24" COLD PAN 5B W/ TOWEL & SOAP 3 "x24 "x36" EAGLE S.S. HAND SINK wI CABT. 6F ICE BIN: S- 420 22" X 34" X 76.5" MANITOWOC QY -0424A 400 LBS. ICE MACHINE 10J FS 1/2" 50" 1/2" 84" C 1.1A 1 115 - -- 22 X 14 X 26.5 MANITOWOC IB-0824YC 800 LBS. ICE MACHINE 10K 6" D 11.7A 1 208/230 ON ROOF 34" X 24.13 X 2535' MANITOWOC CVO -0875 REMOTE CONDENSER 10Kc KITCHEN EQUIPMENT 450 1 0" 1 1 /2' FS 2" 1 0" 3/4" SEE DETAIL 93 ° x42" KEC CUSTOM 93" CHINESE RANGE (L) 20A 190 1 0" 1 1/2" FS 2" 10" 3/4" SEE DETAIL 42 "x42" KEC CUSTOM 42" CHINESE RANGE 200 122 EA. 14 "x2 3/4 30" C 1 1 15 15 1/2" X 34 1/2' (EACH) FRYMASTER MJ45 FRYER (2) 210 92 30" 3/4" FS 2" 30" 3/4" 30" C 11A 1 115 35.5 °X30.4 "X32.75° RATIONAL CPC 61 GAS COMBI OVEN 24E FS C 15A 1 120 NEMA 5 -20P 19.9 "X34.5"X41.3' WINSTON HA4005 RICE HOLDING CABINET 24H 32 30" 1/2" 22 "x15" RINNAI PER -55A -N RICE COOKER 25A 24 "x 30" x 24" KEC CUSTOM RICE COOKER STAND 26A FS 3/4" 130" D 500W 1 1.5 115/208 SEE PLAN KEC CUSTOM WALK -IN COOLER UNIT 31 FS 3/4" 130" D 500W 1 1.5 115/208 SEE PLAN KEC CUSTOM WALK -IN FREEZER UNIT 32 FS C 8.5A 1 1 /3 115 SELF CONTAINED 27 RANDELL 9404F 2T WORKTOP FREEZER 32G FS C 1 2A 1 , 1 1 /2 11 SELF CONTAINED 84 "x33 "x35" RANDELL 9050K -7 84" REF. PREP. TABLE MA FS C 5.5A 1 /4 115 SELF CONTAINED 32 "x32.75 "x36 RANDELL 9412 -32 -7 32" REF. PREP. TABLE 34H FS 2" 14" 3/4" 14" 3/4" 100 "X30" KEC CUSTOM- (PS -100L) POT SINK 40A FS 2" 14" 1/2" 14" 1/2" 2 COMPARTMENT 96 "x30" KEC CUSTOM- (VS -96) 96" VEGETABLE SINK 41B S.S. (NO BKSPL) SEE PLAN KEC CUSTOM WORK TABLE (ISLAND) 42A 18GA POLISHED (WALT MTD. © 59" A.F.F.) SEE PLAN KEG CUSTOM (NSF) 12 "D S.S. WALL MTD, SHELF 43A 18GA POLISHED (WALL MTD. @ 71" A.F.F.) SEE PLAN KEC CUSTOM (NSF) 16 "D S.S. WALL MTD, SHELF 43B 4 SHELVES MTD. © 8 A.F.F., 26" A.F.F., 54" A.F.F., 72" A.F.F. SEE PLAN GOLD BOND VARIES 18'D WIRE SHELVES 44A 4 SHELVES MTD. ® 36' A.F.F., 48" A.F.F., 60" A.F.F., 72" A.F.F. 24" X 36" GOLD BOND VARIES 24 "D WIRE SHELVES 44C 3 SHELVES MTD. @ 36 A.F.F., 54' A.F.F., 72 A.F.F. 24" X 42 50" C 1 1/3 115 12 1/2 ° x21" GENERAL GSM -1/66 FOOD PROCESSOR 45A 50" C 1 1 /2 115 7 1/2" X8 1/2" X20° VITAMIX #748 BLENDER 46A SMALL EQUIPMENT WALL SHELF BY OTHER CUSTOM DETERGENT SHELF 51A 24" C 100W 1 115 ON S.5. COUNTER 160 AROMA ARS-1055S RICE WARMER 54 DC 1600W 1 208 PLUG: NEMA 6 -15R 20 1/87(13 1/4"X18 1/2" SHARP R -23GT MICROWAVE 55 BY G.C. AS REQUIRED BY LOCAL FIRE DEPT., CHECK LOCATION WITH PROJECT MANAGER FIRE EXTINGUISHER 56 2" 24" 1/2" 24" 1/2" W/TOWEL & SOAP 14 1/4 ° x18 1/2" EAGLE HSA -10 -FK HAND SINK 57B SEE DETAIL KEC PAPER TOWEL & SOAP DISPENSER 58 WALL MOUNT 12 "x15 "x78" KEC 5 -TIER LOCKER (2) 61A 20 "x20 "(+4")x23" USA SAFE B2320WD -LG6 SAFE 62A POS EQUIPMENT 24" C 500W 1 115 CUSTOM 11 1/4 "x14 1/2 "x9" RESNOS S 460 CASH REGISTER SYSTEM (2) 81 50" C 100W 1 115 SEE DETAIL CUSTOM COMPUTER 83A 48" X 28' X 42' KEC CUSTOM MANAGER STATION 84C 24" C 50W 1 115 SEE PLAN P05 PRINTERS (2) 86A 50" C 50W 1 115 FAX 87 MEP EQUIPMENT 132" D 1000W 115 SEE MECH. DWG. SEE PLAN CAPTIVE AIR CUSTOM EXHAUST HOOD M1 SEE MECH. DWG. 12" X 6" X 18" CAPTIVE AIR CUSTOM HOOD CONTROL PANEL M4 1 SEE MECH. DWG 24 "x24" CAPTIVE AIR FIRE SUPPRESSION SYSTEM M6 BY G.C. D 3" 36" 3/4" 36" 3/4" FLOOR TYPE 24" X 24" X 10' MOLDED STONE MSB2424 MOP SINK P1 BY G.C. SEE P_UMB'G DWG. 30 " C 115 SEE PLUMBING DWG -0R SPECIFICATIONS GAS WATER HEATER w/ RECIRCULATION PUMP &TIMER P2 84" C 100W 1 115 IN S.S. COUNTER SEE PLAN MUSIC EQUIPMENT /SHELF EIA SEE CEILING PLAN MUSIC SPEAKER E1B WI DOME BASE SEE PLAN PANASONIC M-336 CCD SECURITY CAMERA E4A 84" C 50W 1 1 15 W/ EMI LOCK SEE PLAN TOSHIBA (TIME LAPSE) SECURITY VCR E4B BY G.C. SEE ELEC. DWG ELECTRICAL PANEL E7 SIGNAGE VERIFY D 20A 1 115 SEE SIGN DWG DETAIL CUSTOM I.D. SIGN 51 VERIFY D 200W 1 115 SEE SIGN DWG DETAIL CUSTOM LOGO S2 VERIFY D 500W 1 115 SEE SIGN DWG DETAIL CUSTOM MENU BOARD 56 99" D 500W 1 1 15 SEE SIGN DWG DETAIL CUSTOM BEVERAGE SIGN 57 FURNITURE SE DETAIL CUSTOM BEVERAGE COUNTER F2 SEE DETAIL CUSTOM TRASH RECEPTACLE F3 SEE DETAIL CUSTOM CHAIR Cl SEE DETAIL CUSTOM STOOL C2 SEE DETAIL CUSTOM SETEE C3 SEE DETAIL CUSTOM EXTERIOR CHAIR C4 21 ° X24 "x30" CUSTOM 24" X 21" TABLE T1 21 ° X24 "x42" CUSTOM 24 "X27" TABLE HIGH T2 SEE PLAN CUSTOM EXTERIOR TABLE T4 36" DIA. CUSTOM ROUND HIGH TABLE T5 MECHANICAL EQUIPMENT SCHEDULE (THIS SHEET) KEY DESCRIPTION LOAD VOLT -0 FEEDER O.C. PROTECTION REMARKS C.B. FUSE DISC. RTU -1 ROOFTOP UNIT 13.74 208-3 (3 #6 + #10G) 1"C * -- 60A 3P 1. kVA NEMA 3R 2. RTU -2 ROOFTOP UNIT 13.74 208 -3 (3 #6 + #10G) 1"C * -- 60A 3P 1. kVA NEMA 3R 2. RTU -3 ROOFTOP UNIT 10.4 208 -3 (3#8+#10G) 1"C * -- 60A 3P 1. kVA NEMA 3R 2. SF -1 KITCHEN HOOD 3 208 -3 (3 #12 + #12G) 3/4"C * -- 30A 3P 1. (SUPPLY FAN) HP NEMA 3R 2. EF -1 EXHAUST FAN 1 208 -3 (3#12 + #12G) 3/4 "C * -- 30A 3P 1. HP NEMA 3R 2. EF -2 EXHAUST FAN 1 208 -3 (3 #12 + #12G) 3/4 "C * -- 30A 3P 1. HP NEMA 3R 2. EF -3 EXHAUST FAN 1/4 120 -1 (2 #12 + #12G) 1/2"C * -- MOTOR HP SWITCH 32 WALK -IN FREEZER (REMOTE CONDENSOR) 2.3 kVA 208 -1 (2 #10+ #100) 3/4"C * 20A 30A 2P NEMA 3R 3. 31 WALK-IN COOLER (REMOTE CONDENSOR) 1.9 kVA 208 -1 (2 #10 + #10G) 3/4 "C * 20A 30A 2P NEMA 3R 3. 10KC ICE MACHINE (REMOTE CONDENSOR) 2.4 kVA 208 -1 (2 #10 + #10G) 3/4 "C * 15A 30A 2P NEMA 3R 3. REVIEWED FOR CODE CC MPLIANCE NFPA 70 - NEC JAN 1 6 2008 City O'' Tukwila BUILDING DIVISION REV. DATE DESCRIPTION BY a ®a ©a® 10/19/07 MECHANICAL P.C. MH I NOTE: 1. ALL CUSTOM EQUIPMENT SHALL BE APPROVED BY NSF. 2. ALL EQUIPMENT SHALL BE APPROVED BY AGA, UL AND NSF IF APPLIED. 3. ALL EQUIPMENT SHALL MEET LOCAL GOVERNMNET CODE. GENERAL NOTES, THIS SHEET: 1. ALL ROOF MOUNTED EQUIPMENT SHALL BE IN NEMA -3R ENCLOSURES. 2. ALL CONDUIT RUNS SHOWN ON THE ROOF SHALL BE RUN BELOW THE CEILING SPACE WHERE AMBIENT TEMPERATURE WILL BE BELOW 30* C. FINAL CONNECTIONS TO THE ROOF EQUIPMENT IS LIMITED TO 5' -0' OF DIRECT SOLAR EXPOSURE. 3. ALL ROOF RECEPTACLES SHALL BE GFCI TYPE. 4. VERIFY ALL FUSE SIZES AND TYPES WITH THE AIR CONDITIONING EQUIPMENT MANUFACTURER PRIOR TO INSTALLATION. 5. REVIEW THE MECHANICAL PLANS FOR THE AIR CONDITIONING CONTROL REQUIREMENTS AND SCOPE OF WORK PRIOR TO BIDDING AND INCLUDE ALL COSTS IN BID. 6. VERIFY CONNECTION POINTS OF ALL HVAC EQUIPMENT PRIOR TO INSTALLATION. 7. SEE MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF MECHANICAL EQUIPMENT AND THERMOSTATS. PROVIDE RACEWAY SYSTEM FOR ALL CONTROL WIRING AS REQUIRED BY MECHANICAL PLANS. ELECTRICAL NOTES THIS SHEET: O PROVIDE 3/4" C WITH PULL WIRE TO THERMOSTAT LOCATION(S). COORDINATE LOCATIONS WITH OWNER, MECHANICAL PLANS, AND MECHANICAL CONTRACTOR. O REMOTE CONDENSER FOR WALK -IN COOLER, WALK -IN FREEZER, AND ICE MACHINE. FIELD VERIFY EXACT LOCATIONS WITH OWNER AND EQUIPMENT SUPPLIER PRIOR TO ROUGH IN. FIELD VERIFY EXACT LOCATIONS WITH OWNER AND EQUIPMENT SUPPLIER PRIOR TO ROUGH IN. O3 HOMERUN CIRCUIT VIA HOOD CONTROL PANEL. COORDINATE CONTROL PANEL WRING WITH HOOD SUPPLIER / MANUFACTURER. ® EXISTING DUPLEX OH PROTECTED RECEPTACLE(S) IN WEATHERP ROOF JUNCTION BOXES ON ROOF TOP CIRCUITED TO EXISTING HOUSE PANEL 'H'. ® ROOFTOP UNITS PROVIDED AND INSTALLED DURING SHELL CONSTRUCTION. COORDINATE LOCATIONS WITH SHELL CONTRACTOR. ® EXTERIOR SIGNS: PROXIDE MANUAL TIMER WITH 24 HOUR DIAL & MANUAL OVER RIDE. -- (2,4,6) SLOPE 1 /4 ":1 ' -O" N V 810 LBS': LI_Nj SF -1 N N® A- (37,39,41) B--6 NOTES: * SEE PANELBOARD SCHEDULES FOR CIRCUIT BREAKER SIZE ** SEE PLAN VIEW FOR FEEDER SIZE 1. DISCONNECT SHALL BE NON-FUSED. 2. VERIFY MOCP IS ACCEPTABLE WITH MANUFACTURER, ELSE PROVIDE FUSIBLE DISCONNECT. 3. VERIFY EQUIPMENT LOCATION PRIOR TO SETTING DISCONNECT. 4. SEE MECHANICAL PLANS FOR EXACT LOCATIONS. TYP. J BOX DUCT SMOKE DETECTOR uiIIIh ,nrlllllllu... I AC - ''IIIIIIIn'I _.III IAC -3 \\ 35 L -z 0 m� fll 2J S 1 T) B- (20,22,24) Ph ,I n 0 // // // // // / / B -10,12 RECEIVED CRY Of: TUKWILA IJAN 1- 2 2008 ROOF PLAN (ELECTRICAL CONNECTIONS) SCALE: 1 /4 " =1' -0" B N 8 0 1 2 4 16 PANDA RESTAURANT GROUP, INC. Contact Person: Jerald Earl 1683 WALNUT GROVE AVE. ROSEMEAD, CALIFORNIA 91770 Direct: 360.885.1 135 Telephone: 626.714.8971 Facsimile: 626.372.8310 PROPERTY OWNER: WIG PROPERTIES LLC -SS 4811 134TH PL SE BELLEVUE, WA 98006 THESE DRAWINGS. DESIGNS. SKETCHES. IDEAS. ARRANGEMENTS AS WELL AS ANY AND ALL ELECTRONIC FILES AND /OR DWGS ARE THE SOLE AND EXCLUSIVE PROPERTY OF PANDA RESTAURANT GROUP INC. & VIGEN ARCHITECT. THESE PLANS WERE CREATED AND DEVELOPED BY AND FOR THE ARCHITECT'S WORK. NOTHING CONTAINED OR REPRESENTED ON THESE DOCUMENTS SHALL BE USED BY OR DISCLOSED TO ANY PERSON. FIRM OR CORPORATION FOR ANY PURPOSE WITHOUT THE EXPRESSED WRITTEN CONSENT OF 'ANITA RESTAURANT GROUP. INC. & VIGEN ARCHITECT. THE WORK CONTAINED ON THESE DWGS AND DOCUMENTS IS CREATED ONLY FOR THIS PROJECT AT THIS TIME 1.. • •1.]: •: •1. : :4114• „ 4iP • : FUTURE WORK(S) OR PROJFCT(S) • REVISIONS: • • ISSUE DATE: • 1ST 2ND 3RD 4TH STH 6TH • ARCHITECT • ■ PROJECT: • PANDA EXPRESS "SOUTHCENTER MARKETPLACE" 17100 SOUTH CENTER PARKWAY TUKWILA, WA PANDA PROJECT #: S4- 08 -D167 ARCH PROJECT #: H702.020 DATE #: 8/25/07 THESE DRAWINGS TO BE USED ONLY FOR THE PROJECT LOCATED ABOVE. STATE-E):l - WASHINGTON VIGEN ARCHITECT A R C H I T E C T U R E& P L A N N I N G 1127 E. Olive Avenue Fresno, CA 93728 Phone: 559.268.2711 Fax: 559.268.1172 Web: www.vigen.corn SHEET NO. E -2.1 ELECTRICAL ROOF PLAN ADDENDUM SUBMITTAL 12/18/A7 LIGHTING FIXTURE SCHEDULE PROVIDED FOR INFORMATION ONLY. VERIFY AND INSTALL PER ELECTRICAL DRAWING ISSUED 7/24/07 ITEM SYMBOL DESCRIPTION QTY. MFR. & CAT. NO. LAMPS X WATTS REMARK C ' L1 T — BAR CEILING RECESS MOUNTED FLUORESCENT LIGHTING FIXTURE, 2'x4', 120V WITH ONE ELECTRONIC BALLASTS AND T -8 LAMPS. EXTRUDED VIRGIN LENS. BAKED -ON WHITE ENAMEL FINISH. 7 LIGHTOLIER FIXTURE: XP2GVA332120 - 03 T8 0830 3x32W KITCHEN CEILING LIGHTS. FURNISHED BY OWNER L1A T -BAR CEILING RECESS MOUNTED FLUORESCENT LIGHTING FIXTURE, 2'x4', 120V WITH TWO ELECTRONIC BALLASTS AND T -8 LAMPS. EXTRUDED VIRGIN LENS. BAKED -ON WHITE ENAMEL FINISH. 2 LIGHTOLIER FIXTURE: XP2GVA332120 -03 T8 0830 3x32W MIN. 1 FT. CANDLE KITCHEN CEILING LIGHTS. FURNISHED BY OWNER NIGHT LIGHTS. r oL1A 108 LIGHT, DUAL HEAD WITH BATTERY PACK, 120V, WHITE COLOR 6 LIGHTOUER E1- 25NH -12W 2X12 WATT HALOGEN LAMPS SUPPLIED W /FIXTURE FURNISHED BY OWNER CEMERGENCY 0 L3 M L4 20 L4 UNIVERSAL MOUNT EXIT SIGN, LED LIGHTED, 120V WITH BATTERY PACK, 2 FACE, GREEN LETTER LIGHTOUER FIXTURE: LUNW2G (DOUBLE FACE) FIXTURE: LUNW1G (SINGLE FACE) FIXTURE SUPPLIED W/ LED UGH11NG FURNISHED BY OWNER L6A Ilk L6A HOOD LIGHT 1 Q FURNISHED & INSTALLED BY EQUIPMENT SUPPLIER CF14EL / A19 3000K ELECTRICAL CONTRACTOR TO DO THE WIRING K 1D0 L6B WALK —IN COOLER FLUORESCENT LIGHT, 120V. 48" 2 KASON F IXTURE: #1810E00048 2x32W FURNISHED BY OWNER 1 01 •' LEE ABI WY © L17A DOWNLIGHT, RECESSED INCANDESCENT 21 LIGHTOLIER 1002P1 W/1005 TRIM WESTINGHOUSE PAR 30 3000 K 15W COMPACT FLUORESCENT LAMP FURNISHED BY OWNER C _730 �� FLUORESCENT WALL MOUNTED FIXTURE CENTER ABOVE MIRROR IN BOTH RESTROOMS 2 LIGHTOUER ALTER QVW8SPFOS2FT- 120 -BR SYLVANIA DULUX FT4OD /83OR5 (2 PER FIXTURE) CENTER OVER MIRROR IN BOTH TOILET ROOMS FURNISHED BY OWNER L71 1 120V, 13 OSQUARELI�H FLUORESCENT 2 FIXTUREEQVWISPASQ2QT0120F4�L TUBE L DULUX I Q ADRBASE CF18DT /E IN 830 RESTROOM CEILING FURNISHED BY OWNER 91 L72 ® ig L73 ALCYON GLASS RING MR16 TRACK HEAD 27 LIGHTOLIER FIXTURE: 22GR6WH SYLVANIA 37W IR MR16 FL35 (OR EQ.) ACCENT LIGHTING FURNISHED BY OWNER ® An ® L DOWLIGHT, RECESSED IN GYP BD. SOFFIT 5 LIGHTOUER: 2000LV W/ 2008 BRUSHED GOLD REFLECTOR SYLVANIA 37W IR MR16 FL35 (OR EQ.) IN SOFFIT © SODA STATION FURNISHED BY OWNER ® 74A j L74A DOWLIGHT, RECESSED IN GYP BD. SOFFIT W /GLASS RING - OVER SERVING UNE ONLY g LIGHTOLIER: 2000LV W/ 2008 BRUSHED GOLD REFLECTOR AND 1302 GLASS RING SYLVANIA 37W IR MR16 FL35 (OR EQ.) IN SOFFIT SERVING LINE FURNISHED BY OWNER 3 7 L76 0 L76 DECOR UGHT FOR CHINESE LANTERNS 0 SEA GULL LIGHTING 6905X6LE -962 SEAGULL 97102 13W BI PIN BASE SHORTEN CORD IN FIELD INSTALL W/0 GLASS SHADE FURNISHED BY OWNER 13 Ala — SINGLE CIRCUIT TRACK, MOUNTED WITH 18" EXTENSION, WHITE 10 LIGHTOLIER TRACK: #6000 —WHITE MOUNTING KIT #7584 WATT RATING PER LOCAL CODE FURNISHED BY OWNER I I T18 I I SINGLE CIRCUIT TRACK, WHITE 1 LIGHTOLIER TRACK: #6000 —WHITE 0 WATT ALRCODE PER WNEISHED BY TS = C ( r LIGHTING NOTES THIS SHEET: XX �i CIRCUIT EMERGENCY LIGHTS AND EXIT SIGNS AHEAD OF LOCAL SWITCHING FOR CONTINUOUS OPERATION. CIRCUIT WITH SAME CIRCUIT AS GENERAL LIGHTING CIRCUIT IN SAME AREA AS PER N.E.C. 0 VERIFY TIE ---IN LOCATION AND REQUIREMENTS OF MENU BOARD SIGN WITH OWNER AND SIGN SUPPLIER. Q PROVIDE UNSWITCHED HOT WIRE TO INNER LAMP FOR CONTINUOUS OPERATION (NIGHT UGHT). O PROVIDE CONNECTION TO W.I.C. AND W.I.F. SHOW LIGHTS AND AREA LIGHTS. CIRCUIT AS SHOWN. • DOUBLE -POLE / DOUBLE -THROW SWITCH AT RESTROOMS FOR CONTROL OF LIGHTING / FAN INTERLOCK. SEE RESTROOM EXHAUST FAN CONTROL DIAGRAM, SHEET E -3.1. O PROVIDE AND INSTALL 24 -HOUR, 2- CHANNEL (WITH 2 CONTACTS PER CHANNEL(NO) TIME CLOCK (TC -1) (365 DAY PROGRAMMABLE) FOR CONTROL OF EXTERIOR LIGHTING (BUILDING MOUNTED GOOSENECKS), SITE SIGNAGE, AND BUILDING MOUNTED SIGNAGE CIRCUITS (CONTROLLED VIA LIGHTING CONTACTORS LC -1 AND LC -2). SEE LIGHTING CONTACTOR DETAILS (LC -1 AND LC -2), SHEET E -3.1. 0 PROVIDE AND INSTALL LIGHTING CONTACTORS LC -1, LC -2, AND LC -3 ADJACENT TO PANELS FOR CONTROL OF EXTERIOR LIGHTING AND SIGNAGE CIRCUITS. SEE LIGHTING CONTACTOR DETAILS, SHEET E -3.1. *NOTE: PROVIDE OVERRIDE SWITCH ADJACENT TO SWITCHBANK TO OVERRIDE OPERATION OF LC -2. 0 PROVIDE JUNCTION BOX AND CIRCUIT FOR CONNECTION TO NEON LIGHTING / SIGNAGE ABOVE SERVING LINE. VERIFY EXACT LOCATIONS AND TIE -IN REQUIREMENTS WITH OWNER AND SIGN PROVIDER. a PROVIDE SWITCHBANK IN LOCATION SHOWN FOR CONTROL OF INTERIOR DINING ROOM LIGHTING AND MENU SIGNAGE. SEE SWITCHBANK DETAIL, THIS SHEET. Ca EXTERIOR FIXTURE TYPES L65 AND L66 ARE INSTALLED AND CIRCUITED TO HOUSE PANEL 'H' UNDER SHELL CONSTRUCTION. 11 VERIFY TIE -IN LOCATION AND REQUIREMENTS OF BEVERAGE SIGN WITH OWNER AND SIGN SUPPLIER. 12 PATIO FIXTURES ARE INSTALLED UNDER SHELL CONSTRUCTION AND CIRCUIT STUBED UP ADJACENT TO PANEL 'L'. CONTINUE CIRCUIT AS SHOWN VIA LC -2 TO PANEL 'L'. I3 CIRCUIT DINING AREA FIXTURES SHOWN (MARKED WITH NL) AHEAD OF LOCAL SWITCHING FOR CONTINUOUS OPERATION (NIGHT LIGHT). LIGHTING GENERAL NOTES 1. ALL FLUORESCENT FIXTURES SHALL HAVE ELECTRONIC BALLASTS WITH 20% OR LESS THD. 2. CONTRACTOR TO PROVIDE ALL REQUIRED HARDWARES, BRACKETS, LAMPS, TUBES, ...ETC. FOR A COMPLETE INSTALLATION. 3. ALL LIGHTING FIXTURES SHALL BE PERMANENTLY ATTACHED TO THE CEILING PER N.E.C. 410- 16(C). 4. CONTRACTOR TO INSTALL ALL LIGHTING FIXTURES INCLUDING OWNER- FURNISHED FIXTURES. 5. ALL FIXTURE BALLASTS SHALL BE U.L. LISTED. 6. ALL EMERGENCY LIGHTING SHOULD BE INSTALLED UP TIGHT WITH THE CEILING IN THE KITCHEN & SUPPORT AREA. 4 0,, 6 /" qwn,.... 4e0--- •• ," 40#0— , r 0 u,... "'w. N 'w.. 40r/ft-- .,- p L -34 SEE NOTE 6 A -34 via SW BANK 5k e A -26 via ME wCD i !J u u u u u T18(2') L73 Ad i n W ' 1011 MI II • 1 ����IIII`�rli tip`• Hood ontrol b- PaneI L6A • � � t rit F' t•! L6A L6A • L6A L6A • ' I L6A L6 L6A L6A L6A u n n ILBB 'r ; T18(2') L73 L -34 NOTE SE 6 _i; Q = ow L1 -7j A Bl O 11111 � A -20 72 BELOW a W co III • f J NOTE: ALL EQUIPMENT (INCLUDING SINKS, SHELVING AND WALK -IN) INSTALLED /USED IN THE FACILITY MUST BE APPROVED BY AN ANSI ACCREDITED TESTING COMPANY OR APPROVED BY ENVIRONMENTAL HEALTH DIVISION. w A -24 via LEGEND EGRESS PATH REQUIRES 1 FOOT CANDLE AT FLOOR ALONG THE ENTIRE PATHWAY AND EGRESS DISCHARGE AREA. / — SEE DETAILS 9 & 13/A3.0 & SHT. A1.1 FOR T —BAR CEILING DETAILS. — SEE DETAILS 1/E3.1 FOR SATC BRACING DETAIL Ord 8 7 �— — 1 r REFLECTED CEILING PLAN � N O2 4 SCALE: 1/4"=1'-0" 16 REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC JAN 1 6 2008 City Of Tukwila B ILDING D SI RECEIVED MY OFT( IWWAI ►JAN i 2008 PANDA RESTAURANT GROUP, INC. Contact Person: Jerald Earl 1683 WALNUT GROVE AVE. ROSEMEAD, CALIFORNIA 91770 Direct: 360.885.1 135 Telephone: 626.714.8971 Facsimile: 626.372.8310 PROPERTY OWNER: WIG PROPERTIES LLC -SS 4811 134TH PL SE BELLEVUE, WA 98006 THESE DRAWINGS, DESIGNS. SKETCHES. IDEAS. ARRANGEMENTS AS WELL AS ANY AND ALL ELECTRONIC FILES AND /OR DWCS ARE THE SOLE AND EXCLUSIVE PROPERTY OF PANDA RESTAURANT GROUP INC. & VIGEN ARCHITECT. THESE PLANS WERE CREATED AND DEVELOPED BY AND FOR THE ARCHFTECT'S WORK. NOTHING CONTAINED OR REPRESENTED ON THESE DOCUMENTS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WRHOUT THE EXPRESSED WRITTEN CONSENT OF PANDA REMIJRANT GROUP. INC. & VIGEN ARCHITECT. THE WORK CONTAINED ON THESE DWGS AND DOCUMENTS IS CREATED ONLY FOR THIS PROJECT AT THIS TIME AND NO OTHER. AND NOT FOR OTHER RELATED.IMPIJED. OR FUTURF WORK(S) OR PROJFCT(S) • REVISIONS: ■ DATE 10/31/07 11/09/07 PRO CHANGES • ISSUE DATE: e • ARCHITECT • • PROJECT: • DESCRIPTION BY VIGEN ADDENDUM SUBMITTAL 1 2/1 8/07 ARCHITECT A R C H I T E C T U R E& P L A N N I N G 1127 E. Olive Avenue Fresno, CA 93728 Phone: 559.268.2711 Fax 559.268.1172 Web: www.vigen.com PANDA EXPRESS "SOUTHCENTER MARKETPLACE" 17100 SOUTH CENTER PARKWAY TUKWILA, WA PANDA PROJECT #: S4- 08 -D167 ARCH PROJECT #: H702.020 DATE #: 8/25/07 THESE DRAWINGS TO BE USED ONLY FOR THE PROJECT LOCATED ABOVE. REGISTERED I ARCOITECT RY T AN ITEGEN E AVASHINGTON ELECTRICAL LIGHTING PLAN AND LIGHTING NOTES Use LPA (W /sf) 0.9 Use Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches ' 7.11 LPA (W /sf) 1.0 Automotive facility Convention center 1,2 1.2 Penitentiary and other Group 1 -3 Occupancies Police and fire stations' 1.0 1.0 Courthouse Cafeterias, fast food establishments', restaurants /bars' 1.3 Post office 1.1 Dormitory 1.0 Retail retail banking, mail concourses, wholesale stores (pallet rack shelving) School buildings (Group E Occupancy only), school classrooms, day care centers Theater, motion picture Theater, performing arts Transportation 1.5 1.2 1.2 1.6 1.0 Exercise center 1.0 Gymnasia', assembly spaces' 1.0 1.0 Health care clinic Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.2 Hotel /motel 1.0 Warehouses 'ssforage areas 0.5 Hotel banquet/conference /exhibition hall 2.0 1.6 Workshops Parking garages 1.4 0.2 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) Laundries 1,2 TYPE 'L74A': RECESSED INCANDESCENT DOWN LIGHT. 10 Libraries 1.3 Plans Submitted for Common Areas Only' 1.2 0.8 Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses" Common areas, corridors, toilet facilities and washrooms, elevator lobbies Museum 1.1 Project Info Project Address PANDA EXPRESS- SOUTH CENTER MARKETPLACE Date 11/20/2007 17100 SOUTH CENTER PARKWAY For Building Department Use TUKWILA, WA$HINGTON Applicant Name: VIGEN ARCHXTECT Applicant Address: 1127 E. OLIVE AVENUE, FRESNO, CALIFORNIA 93728 Applicant Phone: 1- 559 -268 -2711 Project Description i, J Plans included requirements. [i New Building A Addition r Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option U Prescriptive (e) Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) C No changes are being made to the lighting [ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Prescriptive Spaces Occupancy: (] Warehouses, storage areas or aircraft storage hangers `Other Q ualification Checklist Note: If occupancy type is "Other and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations, Lighting Fixtures: (Section 1521) Check if 95% a or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T -4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify, 2. Metal Halide with a) reflector b) ceramic MH lamps eW 150w c) electronic ballasts 3. LED lights. Location (floor /room no.) Occupancy Description Allowed Watts per ft "* Area in ft Allowed x Area 5 -3.0 FAST FOOD ESTABLISHMENT 1.30 1264.0 1643.2 E3.0 KITCHEN AND WORK ROOM IS EXEMPT PER 1512.1 ITEM #4. 2 80.0 16 0 , 0 E3.0 TYPE ' L72 ' : CEILING MOUNTED 2 LAMP FLUORE$CENT, 2 36.0 7 6 . 0 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 1643 .2 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed E3.0 TYPE 'L17A': ROUND RECESSED FLUOR. W/ 15W. LAMP. 19 16.0 304.0 E3.0 TYPE .L71': WALL MOUNTED 2 LAMP FLUORESCENT. 2 80.0 16 0 , 0 E3.0 TYPE ' L72 ' : CEILING MOUNTED 2 LAMP FLUORE$CENT, 2 36.0 7 6 . 0 53.0 TYPE 'L73': LOW VOLTAGE TRACK LIGHTING HEAD. 2 37.0 74.0 53.0 TYPE 'L73': SAME AS ABOVE. EXMPT. PER 1512.2 #6. 43 Schedule with type and features, indicate locations 83.0 TYPE 'L74':RECESS#D INCANDESCENT DOWN LIGHT. 4 37.0 148.0 53.0 TYPE 'L74A': RECESSED INCANDESCENT DOWN LIGHT. 10 37.0 370.0 53.0 TYPE '576: SUSPENDED FLUORESCENT FIX't'U}<E. 8 16.0 128.0 83.0 TYPE 'L1': 2'X4' 2 LAMP LAY -IN FLUORESCENT FIXTURE. 4 62.0 248. 0 E3 - 1 1513.5 Exterior shut -off Schedule with type and features, indicate location n.e. Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 15 o 8.0 L>I ht n '�i111 g , g, o 2006 Washington State Nonresidential .........:.......... .................. .... t : r::.,.. r . f: m� _- - . ' :::. _ ;.., = == o , and T a s er.pern�t Plans Checkr�st LTG CHK. Energy code Compliance Forms Revised July 2007 Project Address PANDA EXPRESS SOUTH CENTER MARKETPLACE 1 (Date 11/20/2007 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) I Code Section I Component Information Required Location I Building Department on Plans I t Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations 33 - 1 n • a • 1513.2 Area controls Maximum limit per switch 1513.3 Daylight zone control Schedule with type and features, indicate locations yes vertical glazing Indicate vertical glazing on plans E3 -1 n . a, overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib /special Indicate separate controls E3 - 1 1513.5 Exterior shut -off Schedule with type and features, indicate location n.e. (a) timer w/backup Indicate location n. a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location n, a. 1513.6,1 (a) occup. sensors Schedule with type and locations n. a. 1513,6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans yes 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes 1514 Max. watts Indicate watts for each exit sign LIGHTING POWER ALLOWANCE (Section 153041532) Yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture n. a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps. ballasts, watts per fixture MOTORS (Section 1511) 1511 Elec motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency l TRANSFORMERS (Section 1540) 1540 Transformers Indicate size and efficiency COMPRESSION ELECTRICAL METALLIC SIZE (DIAMETER) 1/2" 3/4" 1" STRUT TUBING (EMT) ONLY* L (MAX. HEIGHT) 4I.OP 51...211 6 * STRUTS OTHER THAN E.M.T. MAY REQUIRE ENGINEERING CALCULATIONS, NOTE: A STRUT FASTEN TO THE MAIN RUNNER SHALL BE EXTENDED TO AND FASTENED TO THE STRUCTURAL MEMBERS SUPPORTING THE ROOF OR FLOOR ABOVE. THE STRUT SHALL BE ADEQUATE TO RESIST THE VERTICAL COMPONENT INDUCED BY THE BRACING WIRE, THESE HORIZONTAL RESTRAINT POINTS SHALL 5E PLACED 12 FEET ON CENTER IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6 FEET FROM EACH WALL. ATTACHMENT OF THE RESTRAINT WIRES TO THE STRUCTURE ABOVE SHALL BE ADEQUATE FOR THE LOAD IMPOSED. COMPRESSION STRUT SHALL NOT BE MORE THAN 1:6 OUT OF PLUMB IF THE STRUT IS NOT PLUMB, IT SHALL BE RESTRAINED FROM HORIZONTAL SLIPPAGE AT BOTH ENDS. #12 GA. (2.70mm) SPLAYED WIRES @ 12' -O" D.C. EACH WAY 4x4 GRID (TYP.) VERT. #12 GA. (2.70mm) SUPPORT WIRES @ 4' -0" O.C. MAX. EACH WAY, PERIMETER WALL 0 1t' DIAMETER ELECTRICAL METALLIC TUBING COMPRESSION POST -TIGHT TO STRUCTURE #12 GA.(2.70 mm)SPLAYED WIRE BRACING AT 45 (4) DIRECTIONS, 12' -0" ON' CENTER EACH DIRECTION- SPLAY WIRES SHALL NOT BE ATTACHED TO CROSS RUNNERS. 1 DIA, ELECTRICAL METALLIC TUBING COMPRESSION POST AT 12'-0" o.c. EACH WAY a n 41_011 41_01/41_0" 41_011 41_ T • \°/ TYP. BRACING DETAIL 1. BOTTOM EDGE ATTACHMENTS DEVICES SHALL HAVE HOLDING POWER TESTS CERTIRIED BY MFG AVAILABLE ON REQUEST 2. EACH SUSPENSION WIRE SHALL NOT HANG MORE THAN 1:6 OUT OF PLUMB UNLESS A COUNTER SLUNG WIRES IS HORIZONTAL BRACING IS PROVIDED FRAMING MEMBER 1444444 CROSS RUNNER NOTES #12 GA. VERT. SUPPORT WIRES @ 4' -0" O,C, MAX. EA. WAY. 3 TIGHT TURNS MIN, @ BOTH ENDS,TYPICAL. TURN CEILING RID LEVEL PRIOR TO SETTING TUBE. 45 MIN TYPICAL MAIN RUNNER - LEVEL PRIOR TO SETTING COMPRESSION POST 1/4'tIN 10' 1. EACH 4x4 GRID SHALL BE CAPABLE OF WITHSTANDING A MIN. HORIZONTAL LOAD OF 115# 2. HANGER WIRES AS INDICATED SHALL BE TIED TO STRUCTURAL MEMBERS 3, SPLAYED WIRES AS INDICATED SHALL BE TIED TO STRUCTURAL MEMBERS 4. SIMILAR BRACING FOR SUSP. GYP. BD. 5. SUSP. WIRES & EMT NEED NOT BE WELDED @ CROSS RUNNER LOC's 6. LIGHT FIXTURES TO BE SUSPENDED w/ ADDITIONAL SUSPENSION WIRES • GG 4, r , ? �• - , 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summa 2006 Washington Stale Nonresidential Energy Code Compliance Forms Maximum Allowed Lighting Wattage Proposed Lighting Wattage Revised July 2007 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manudt'' may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or •;.;>, =„ the wattage of current limiting devices or of the transformer. .....� 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. rEXPR28 1:7 2006 Washington State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: wMry'9 NwhwyH.. Interior. Lighting Surnma I 2006 Washington State Nonresidential Energy Code Compliance Forms TABLE 15 »1 Unit Lighting Power Allowance LPA ootnotes for Table 15- In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feel. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: 1) located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wail), adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be de computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (ac of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. a) b) 2006 Washington State Nonresidential Energy Code Compliance Forms Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6,1, Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry /exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which Is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching, EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall he equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1, Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or 2006 Washington State Nonresidential Energy Code Compliance Form 2006 Washington State Nonresidential Energ Code Compliance Form i Revised July 2007 illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall - mounted, manual switch capable of turning off lights when the space is occupied, EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off" feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, If power is interrupted. Automatic time switches shall incorporate an over -ride switching device which; a. is readily acc b. Is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and 5. controls an area not exceeding 5,000 ft or 5% of the building footprint for footprints over 100,000 ft whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components. equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner, Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540-TRANSFORMERS The minimum efficiency of a low voltage dry -type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP- 1- 2002). S 555 sizteariEWED FOR CODE COMPLIANCE: NFPA 70 - NEC JAN 1 6 2008 City Af Revised July 2007 RECEIVED 01T'Y OF Ti IKUVI4 A, IJAN I- 2 2000 I • N I' 1 . 1 I dl I I dl I I dl I I dl I F PANDA RESTAURANT GROUP, INC. Contact Person: Jerald Earl 1683 WALNUT GROVE AVE. ROSEMEAD, CALIFORNIA 91770 Direct: 360.885.1 135 Telephone: 626.714.8971 Facsimile: 626.372.8310 PROPERTY OWNER: WIG PROPERTIES LLC -SS 4811 134TH PL SE BELLEVUE, WA 98006 THESE DRAWINGS. DESIGNS. SKETCHES, IDEAS, ARRANGEMENTS AS WELL AS ANY AND ALL ELECTRONIC FiLES AND /OR DWGS ARE THE SOLE AND EXCLUSIVE PROPERTY OF PANDA RESTAURANT GROUP INC. & VIGEN ARCHITECT. THESE PLANS WERE CREATED AND DEVELOPED BY AND FOR THE ARCHITECT'S WORK. NOTHING CONTAINED OR REPRESENTED ON THESE DOCUMENTS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WITHOUT THE EXPRESSED WRITTEN CONSENT OF PANDA RESTAURANT GROUP. INC. & VIGEN ARCHITECT. THE WORK CONTAINED ON THESE DWGS AND M NTS IS CREATED ONLY FOR THIS PROJECT AT THIS TIM I. AND NO OTHER. AND NOT FOR OTHER RELATED. IMPI IED. OR F1JIURF WORK(5) OR PROJFCT(S), • REVISIONS: • DATE 10/31/07 11/09/07 PRG CHANGES • ISSUE DATE: ■ • ARCHITECT • VIGEN • PROJECT: • DESCRIPTION BY ARCHITECT A R C H I T E C T U R E& P L A N N I N G 1127 E. Olive Avenue Fresno, CA 93728 Phone: 559.268.2711 Fax: 559.268.1172 Web: www.vigen.com PANDA EXPRESS "SOUTHCENTER MARKETPLACE" 17100 SOUTH CENTER PARKWAY TUKWILA, WA PANDA PROJECT #: S4- 08 -D167 ARCH PROJECT #: H702.020 DATE #: 8/25/07 THESE DRAWINGS TO BE USED ONLY FOR THE PROJECT LOCATED ABOVE. • SEAL: ■ [ AR's 11'MAN VTGEN 4T WASHINGTON REGIVER# D ARCHITECT SHEET NO. E -3.1 MECHANICAL FORMS ADDENDUM SUBMITTAL 1 2/1 8/07 ND. TAG PACKAGE # LOCATION SWITCHES ROOFTOP STARTERS OPTION FANS CONTROLLED LOCATION QUANTITY TYPE 0 H.P. VOLT, FLA 1 3 321110AQ Wall Mount SS Wall Mount Box i Light 1 Fan Exh Exhaust In Flre, 2 Relays w/ 2 -DPDT Exhaust 3 1.500 208 4.7 Exhaust 3 1.500 208 4.7 Supply 3 5.000 208 14.1 Motor Type PH Volt HP FLA BREAKER Exh-1 Exh 3 208 1.5 4.7 25 Amp Sup -3 Sup 3 205 5 14.1 -- Amp Exh Exh 3 208 1.5 4.7 15 Amp EXISTING 2000 AMP 120V/208V - 3PH - 4W MAIN SWITCH GEAR NO SCALE 4 • 4 EXISTING CONCRETE SLAB . v .4 EXISTING 2000 AMP MAIN SWITCHBOARD PROVIDED BY LANDLORD Q CONTRACTOR TO PROVIDE UL LISTED APPROVED COMBINATION OF DEVICES (MAIN FEEDER BREAKER AND DOWNSTREAM CIRCUIT BREAKERS IN PANELS) TO PROVIDE SERIES COMBINATION RATINGS OF IOOpOO AIG MINIMUM. SAFE "J" BOX WITH CONDUIT TO ABOVE CEILING BY G.C. SPEAKER WIRES INSTALLED BY OWNER'S VENDOR CAMERA WIRES INSTALLED BY OWNER'S VENDOR TO PHONE BOARD MUZAK SYSTEM SECURITY SUSTEM CREDIT CARD & SECURITY SYSTEM) VCR FIXED S.S. SHELF INSIDE CABINET SECURITY LOCK S.S. CABINET W/ BACKING © 61 A.F.F. ORANGE OUTLET W/ ISOLATED GROUND FOR COMPUTER VOICE (FOR BUSINESS LINE) FAX ORANGE OUTLET W/ ISOLATED GROUND FOR COMPUTER 3/4" CONDUIT FOR TEL TO FRONT COUNTER 1" CONDUIT FOR DATA TO FRONT COUNTER MGR STATION ELEVATION NTS v HASP & LOCK TO HOOD CONTROL PANEL CKT B -35 { 20A C/B CKT B -9 —n 1P g #12 AWG SYSTEM OPERATION: ALL ELECTRICAL POWER FEEDING KITCHEN EQUIPMENT UNDER THE HOOD WILL BE SHUT -OFF WHEN THE OUTPUT POWER OF THE HOOD FIRE SUPPRESSION SYSTEM RELAY IS INTERRUPTED. REFER TO KITCHEN EQUIPMENT PLANS FOR COMPLETE KITGHEN EQUIPMENT REQUIREMENTS REFER TO MEGHANIGAL PLANS FOR REQUIREMENTS IN REGARD BUT NOT LIMITED TO THE HVAG SYSTBW1 CONTROL, KITGHEN HOOD EXHAUST AND SUPPLY FAN INTERLOCK, AND EMERGENCY SRN-DOWN SYSTEM. ELEGTRIGAL CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED ELEC.1RIGAL INSTALLATIONS INDICATED ON THE MEGHANIGAL PLANS. 20A CONTACTOR W/ N.D. CONTACT IN HOOD CONTROL PANEL FRYER COOKING EQUIPMENT EMERGENCY SHUT -OFF WIRING DAIGRAM Q NO SCALE 0 PNL A NEW 200 AMP CONNECT EXISTING 4" CONDUITS TO NEW PANELS A-FB El PNL B NEW 200 AMP Q • • ELECTRICAL PREWIRE PACKAGE CONTROL INPUT 120VAC H1 =LINE. N1= NEUTRAL 15A BKR 1 13 14 UGHT INPUT 120VAC 1 H5 =UNE, N2 -N5 =NEUTRAL 15A 8KR LS -01 16 17 DRAWING NUMBER 321110AQ 20 3 Th FS-01 Y 18 INPUT - 3 WIRE - 3 PHASE - 19 21 INPUT - 3 WIRE - PRASE- 84 ELECTRICAL PACKAGES (ran Switch Shown Installed) ST -X DL-X RA 2 9G ,,.95 WH ST -X OL -x DR Ave 96 WH ST - 0. -X YW A95 VH R4 R3 0 MS -1 C Cl NO BWH TiEC MEE L2 L3 3 PHASE 208V u T1 - 21 T�3�3 3 PHASE 208V L�1 T1 OL- 3 2 x T2 25 L r3 3 PHASE 208V ST T1 OL I1 22 T2�� T2 3 Tai NC) SC.AI E WH BK • ,/. WH azEt JOB NAME Panda Express - Tukwila 114 CS4- 02- 1677IIATE JOB NUMBER 643114 FLA CON BOL F. F. KITCHEN ELECTRICAL PLAN NGE DUIT T TO cV TOP VIEW 2' -3" N) N ©- ----3" DIA. FLANGE FLANGE CONDUIT S.S. PANEL FINISH FLOOR 0 FLANGE CONDUIT - BOLT TO F.F. S.S. 1 -5/8" DIA. TUBE. COREDRILL 6" INTO FINISH FLOOR. FRONT VIEW S.S. OUTLET PANEL 0 1 5/8" 2" BOTTOM VIEW 2' -3" BACK VIEW N) STAINLESS STEEL OUTLET PANEL DETAIL Q NO SCALE S.S. 1 -5/8" DIA. TUBE. COREDRILL 6" INTO FINISH FLOOR. J -BOX PROVIDE BY ELECTRICIAN. MIN. 12" A.F.F. FLANGE CONDUIT BOLT TO F.F. S.S. 1 -5/8" DIA. TUBE. COREDRILL 6" INTO FINISH FLOOR. 1 5/8" 3/4" DIA. CONDUIT -ONLY, PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. EXTEND CONDUIT, INSIDE WALL, TO ABOVE ACCESSIBLE CEILING SPACE PROVIDE 4" OCTAGONAL JUNCTION BOX WITH SCREW THREADS SET AT THE 2 & 8 O'CLOCK POSITIONS AND A PROTECTIVE COVER. REMOTE FIRE PULL STATION. CABLE, AND ANY OTHER MISCELLANEOUS EQUIPMENT SHALL BE PROVIDED BY OTHERS ANSUL PULL STATION 2 NO SCALE Spare Relay Contacts C--RD NO-BL NC -PR DRAWN BY 3 Phase, W/ 2 Exhaust Fans, 1 Supply Fan, 2 Relays w/ 2 -DPDT On /Off w/ Supply Fan, Exhaust on in fire condition I ahel DDsaaption ST MS LS GP TX C GR AF R2-2 - -ZN NC - -dNC4E N C 0 ` � C4 C5 - -eNO C6 6 Starter Fan SwRch Lighted MicroSwitch Ansul/ hem) Relay DPDT Light Switch (1400W max) Hood Light(s) General "Purpose Relay DPDT Transformer Contactor Ground Air Flow Switch O 8/14/2007 18 x 18 x 6 Box MS -1, MS -2 MicroSwitch Ansul C -RD NO -BK NC -BR SPARE RELAY CONTACTS CAN HE USED TO CONTROL ITEMS REQUIRING SHUT DOWN WHEN THE FIRE SYSTEM DISCHARGES, SUCH RI -R5 AS SHUNT TRIP, SIGNALS, RELAY.. ETC. ^na re "eim/ l.arlta Gt9 R2-1 TERMINAL FOR FIELD C R3 - LI1T,1c7 Pyrochem C -RD NO -BK NC -BR WIRING TO BUILDING FIRE PANEL, DRY CONTACTS FOR SIGNAL WILY MS -2 --- — ISNOZt2t a — C2v NC C 7 t 6 ENO ' ND „f -2NC7 a„FFLY- dC7s R3 2 as1r,rn N � C 7 i ON -ONO ND arc -eNc Iregi.n.r1 ca NOTES — — DENOTES FIELD WIRING DENOTES INTERNAL WIRING R4 -1 7e>7 iNEr NC R4 -2 NO WIRE COLDS. BK - BLACK YV - YELLOV BL - BLUE GY - GRAY BR - BROWN PR - PURPLE DR - MANSE OR/DL - DRANGEJBLUE RD - RED (STRIPE) VH - WHITE BL/RI - BLUE/RED (STRIPE) RD/GN - RED /GREEN (STRIPE) DRAWING SHOWN OE-- ENERGIZED NOTE, IF WALL MOUNT PREWIRE, OR FIELD INSTALLED FIRE SYSTEM MICRUSWITCH, THE TERMINALS SHOWING FACTORY WIRING MUST BE FIELD VIRED. NOTE: IF OR FIELD MICROSWI FACTORY MUST BE WALL MOUNT PREWIRE, INSTALLED F /RE SYSTEM TCH TERMINALS SHOWING WIRING FIELD WIRED RECEIVED CITY OF TUKWILA I JAN H 2 2008 PANDA RESTAURANT GROUP, INC. Contact Person: Jerald Earl 1683 WALNUT GROVE AVE. ROSEMEAD, CALIFORNIA 91770 Direct: 360.885.1 135 Telephone: 626.714.8971 Facsimile: 626.372.8310 PROPERTY OWNER: WIG PROPERTIES LLC -SS 4811 134TH PL SE BELLEVUE, WA 98006 THESE DRAWINGS. DESIGNS, SKETCHES. IDEAS. ARRANGEMENTS AS WELL AS ANY AND ALL ELECTRONIC FILES AND /OR DWGS ARE THE SOLE AND EXCLUSIVE PROPERTY OF PANDA RESTAURANT GROUP INC. & VIGEN ARCHITECT. THESE PLANS WERE CREATED AND DEVELOPED BY AND FOR THE ARCHITECTS WORK. NOTHING CONTAINED OR REPRESENTED ON THESE DOCUMENTS SHALL BE USED BY OR DISCLOSED TO ANY PERSON. FIRM OR CORPORATION FOR ANY PURPOSE WITHOUT THE EXPRESSED WRITTEN CONSENT OF PANDA RESTAURANT GROUP. INC. & VIGEN ARCHITECT. THE WORK CONTAINED ON THESE DWGS AND DOCUMENTS IS CREATED ONLY FOR THIS PROJECT AT THIS TIME AND NO OTHER. AND NOT FOR OTHER RELATED. IMPLIED OR FUTURE WORIS(S) OR PROJECT(S). • REVISIONS: • • ISSUE DATE: • DATE • ARCHITECT • DESCRIPTION BY • PROJECT: • ■ SEAL: • VIGEN ARCHITECT A R C H I T E C T U R E& P L A N N I N G 1127 E. Olive Avenue Fresno, CA 93728 Phone: 559.268.2711 Fax: 559.268.1172 Web: www.vigen.com PANDA EXPRESS "SOUTHCENTER MARKETPLACE" 17100 SOUTH CENTER PARKWAY TUKWILA, WA PANDA PROJECT #: S4- 08 -D167 ARCH PROJECT #: H702.020 DATE #: 8/25/07 THESE DRAWINGS TO BE USED ONLY FOR THE PROJECT LOCATED ABOVE. ADDENDUM SUBMITTAL 12/18/07 PANEL L - 100 - A PANEL L - 100 PANEL " A " 208/ 120 VOLT 3 PHASE LUGS ONLY NEUTRAL 4 WIRE SERVICE MOUNTING : SURFACE • ** AIC: GROUND BUS 11 • FLUSH 11 FLUSH X 11 11 DESCRIPTION L R L TISIO MIAIE A 20 0 C 1 2 20 L R TISIO MIAIE DESCRIPTION Walk -in Cooler Comp. M 473 EF -1 0 960 0 854 0 1200 3 Pan Food Warmer " I 0 960 I Blender 4 0 1176 0 1200 21 Walk -in Cooler Fan 0 500 1 5 5 6 0 864 7 0 1200 11 Walk -in Freezer Comp. 500 0 1150 2 0 7 8 0 9 0 1600 4 Pan Food Warmer '' Signage (Bldg Mount) 0 1150 I 9 10 I 12 0 1600 " Walk -in Freezer Fan Signage (Bldg Mount) Freezer 0 500 15 m 12 I 30 0 1600 " Microwave Ref. Prep. Table 0 800 20 In 14 20 0 1600 4 Pan Food Warmer " 180 0 800 I 15 16 I M 473 0 1600 " Microwave 360 0 800 20 17 18 I M 4583 AC-3 0 1600 " 11 0 500 0 800 I 19 20 20 1200 Beverage Dispenser Dining Area Track Lights Sneeze Guard 23 0 1500 I 21 22 I 1100 Neon Light (Menu)/ Beverage sign Sneeze Guard 25 26 0 1500 I 23 24 I 1200 0 1265 Dining Area Track Lights AC -1 28 . M 4583 60 EF -3 26 20 1245 E ^ Dining Area Down Lights • ^ M 4583 I 27 28 L. 1000 .--. 31 Beverage Area Lights " E 540 M 4583 y 29 30 I 1350 _--_ Dining Area Down Lights AC -2 Hood Control Panel M 4583 60 ® 32 .--_ 1500 E 200 Dining Area Track Lights Hood Lighting 1000 M 4583 I MI 34 500 Hot Tea Exit, Emergency, LT, NL • ,, , .•. „ ....,. ....... M 4583 y 35 36 ^ 1050 Remote Cond. (10KC) RICE HOLDING CABINET Serving Line Lights Dining Area Track Lights Dining Area Track Lights SF -1 E 360'; M 1270 30 EU 38 . 1200 M�. �,.. _,. TOTAL .,, ,.. 2760 • ...• �i35'O55 A 0 E 2260 LOADS IN VOLT - AMPERES M 1270 I 39 40 1200 " CONNECTED 46.4 KVA DESIGN 42.6 KVA DEMAND 118 KVA SPARE 82 KVA CONNECTED PHASE A 10.8 KVA PHASE B 12.3 KVA PHASE C 9.2 KVA PHASE BALANCE A TO B 88% B TO C 75% C TO A 85% ALL CIRCUIT BREAKERS ARE 20 AMP, 1 POLE UNLESS NOTED OTHERWISE LIGHTING M 1270 I 41 42 _ � 4.1 360 0.0 Restroom GFI Recept. TOTAL 0 0 M A 0 31308 0 11420_ LOADS IN VOLT - AMPERES 12545 360 M 0 A 0 0 13200 TOTAL 0.0 CONNECTED D.F. DEMAND CONNECTED 72 KVA DESIGN 65 KVA DEMAND 182 KVA SPARE 18 KVA CONNECTED PHASE A 13.0 KVA PHASE B 13.0 KVA PHASE C 11.7 KVA PHASE BALANCE A TO B 100% B TO C 90% C TO A 90% ALL CIRCUIT BREAKERS ARE 20 AMP, 1 POLE UNLESS NOTED OTHERWISE LIGHTING 12.5 HEATING 1.25 15.6 RECEPT. (FIRST 10 KW) 3.6 0.0 1.00 1.44 RECEPT. (REMAINDER) 0.0 0.65 0.50 0.0 MOTORS 27.5 0.0 1.00 27.5 LARGEST MOTOR 3.8 1.25 4.8 APPLIANCES 0.0 46.4 KVA 1.00 0.0 EQUIPMENT 0.0 1.00 0.0 HEATING 0.0 200.0 AMPS 1.00 0.0 TRANSFORMER 0.0 L = LIGHTING R = RECEPTACLE M = MOTOR T = TRANSFORMER SP = SPACE S = SUBFEED E = EQUIPMENT A = APPLIANCE 0 = OTHER SPR = SPARE 1.00 0.0 OTHER 24.6 0.65 16 0.00 0.0 0.00 0.0 0.00 0.0 TOTAL 72 KVA ////// 65.3 KVA LOAD 200 AMPS 182 AMPS DESIGN � 200.8 SPARE AMPS L = LIGHTING R = RECEPTACLE S = SUBFEED E = EQUIPMENT M = MOTOR T = TRANSFORMER SP = SPACE A = APPLIANCE 0 = OTHER SPR = SPARE PANEL L - 100 - A PANEL '' B " 208/ 120 VOLT ** AIC: GROUND BUS 3 PHASE LUGS ONLY NEUTRAL 4 WIRE SERVICE MOUNTING : SURFACE ■1 • X 11 FLUSH 11 DESCRIPTION L R MIAIE A 2Q B C 1 2 L R TISIO MIAIE DESCRIPTION Gas Htr. / Rec. 180 M 473 EF -1 Food Processor 0 854 . 3 4 I M 473 Blender 0 1176 5 6 I M 473 " Carbonator 0 864 7 r c _ 500 JB FOR FIRE ALARM/ DUCT DETECTOR Fr er 0 400 9 1500 Signage (Bldg Mount) Ref. Prep. Table 0 1080 . 11 12 1500 Signage (Bldg Mount) Freezer 0 1020 _ 13 14 30 M 473 EF -2 Ref. Prep. Table 0 1440 " 15 16 L. M 473 " Rice Warmer / Recept_ 180 0 500 _ 17 18 I M 473 • Receptacles 360 ^ 19 20 60 M 4583 AC-3 Ice Machine 0 500 • 21 22 I M 4583 " Beverage Dispenser 0 500 23 24 y M 4583 Ice Machine 0 1476 25 26 _ _ 360 TTB Receptacle Combi Oven 0 1265 _ X 27 28 . M 670 EF -3 Spare E ^ 29 30 til ^ 1800 Show window P.0.5 / Reg. E 550 .--. 31 .--_ E 540 Manager Station Security Cash Reg. E 500 33 _--_ E 540 Hood Control Panel E 300 ^ 35 36 E 200 Music Equipment Hood Lighting 1000 37 38 720 Hot Tea ..} itchen,„,Lights.,,, :..,N ......,„.....,, .1.7,60 ,, , .•. „ ....,. ....... 39 40 0 1217 Remote Cond. (10KC) RICE HOLDING CABINET E 360'; 41 42 L 0 1217 " M�. �,.. _,. TOTAL .,, ,.. 2760 w. 720 ...• �i35'O55 A 0 E 2260 LOADS IN VOLT - AMPERES 3000 3380 M 17257 0 2434 E 1280 TOTAL CONNECTED D.F. DEMAND CONNECTED 46.4 KVA DESIGN 42.6 KVA DEMAND 118 KVA SPARE 82 KVA CONNECTED PHASE A 10.8 KVA PHASE B 12.3 KVA PHASE C 9.2 KVA PHASE BALANCE A TO B 88% B TO C 75% C TO A 85% ALL CIRCUIT BREAKERS ARE 20 AMP, 1 POLE UNLESS NOTED OTHERWISE LIGHTING 5.7 1.25 7.1 RECEPT. (FIRST 10 KW) 4.1 1.00 4.1 RECEPT. (REMAINDER) 0.0 0.50 0.0 MOTORS 15.8 1.00 15.8 LARGEST MOTOR 1.4 1.25 1.8 APPLIANCES 0.0 1.00 0.0 EQUIPMENT 3.5 1.00 3.5 HEATING 0.0 1.00 0.0 TRANSFORMER 0.0 1.00 0.0 OTHER 15.9 0.65 10.3 0.00 0.0 0.00 0.0 0.00 0.0 TOTAL 46.4 KVA / 42.6 KVA LOAD 129 118 AMPS DESIGN 200.0 AMPS SPARE j /�` / 82 AMPS L = LIGHTING R = RECEPTACLE M = MOTOR T = TRANSFORMER SP = SPACE S = SUBFEED E = EQUIPMENT A = APPLIANCE 0 = OTHER SPR = SPARE ALL MAINS ARE 100% RATED j s f f r r rrt'�w.ySyyiG ' NNN _.. NOTES: ** Provide series combination rating of 22,000 AIC „„ GG � _'4•, / < -...... �ir,4mr„✓, r /y4 %urrR+r...rrrr. � '�mr.Nr 42444.,„„„,, 4 •`' w r .lNFUi.r hG r �4r rrr /N ��� / 'vHx.rir REVYEW MPLIANCE CODE Co NFPA 7 - NEC J14"1 1 6 2: City 8f Tukwila B ILDING ' ISN r ruH U// < RECEIVED pry 07 Ti WW1; it JAN - 2008 PANDA RESTAURANT GROUP, INC. Contact Person: Jerald Earl 1683 WALNUT GROVE AVE. ROSEMEAD, CALIFORNIA 91770 Direct: 360.885.1 135 Telephone: 626.714.8971 Facsimile: 626.372.8310 PROPERTY OWNER: WIG PROPERTIES LLC -SS 4811 134TH PL SE BELLEVUE, WA 98006 THESE DRAWINGS. DESIGNS. SKETCHES. IDEAS. ARRANGEMENTS AS WELL AS ANY AND ALL ELECTRONIC FILES AND /OR DWGS ARE THE SOLE AND EXCLUSIVE PROPERTY OF PANDA RESTAURANT GROUP INC. & VIGEN ARCHITECT. THESE PLANS WERE CREATED AND DEVELOPED BY AND FOR THE ARCHITECT'S WORK. NOTHING CONTAINED OR REPRESENTED ON THESE DOCUMENTS SHALL BE USED BY OR DISCLOSED TO ANY PERSON. FIRM OR CORPORATION FOR ANY PURPOSE WITHOUT THE EXPRESSED WRRTEN CONSENT OF PANDA RESTAURANT GROUP. INC. & VIGEN ARCHITECT, THE WORK CONTAINED ON THESE DWGS AND DOCUMENTS IS CREATED ONLY FOR THIS PROJECT AT THIS TIME AND NO OTHER. AND NOT FOR OTHER RELATED. IMPLIED. OR FUTURF WORK(S) OR PROJFCT(S) • REVISIONS: • DATE 10/31/07 DESCRIPTION BY • ISSUE DATE: • • ARCHITECT ■ VIGEN • PROJECT: • ARCHITECT A R C H I T E C T U R E& P L A N N I N G 1127 E. Olive Avenue Fresno, CA 93728 Phone: 559.268.2711 Fax: 559.268.1172 Web: www.vigen.com PANDA EXPRESS "SOUTHCENTER MARKETPLACE" 17100 SOUTH CENTER PARKWAY TUKWILA, WA PANDA PROJECT #: S4-08-D167 ARCH PROJECT #: H702.020 DATE #: 8/25/07 THESE DRAWINGS TO BE USED ONLY FOR THE PROJECT LOCATED ABOVE. REGIWE RED ARCHITECT ADDENDUM SUBMITTAL 1 2/1 8/07 REV. DATE DESCRIPTION BY 0 A A. I ®<1 a PART 1 GENERAL ELECTRICAL SPECIFICATIONS SECTION 16000 11 CODES AND FEOUIREMENTS A. All electrical work shall comply with the requirements of the applicable edition of the National Electrical Code, Local Building Code and as specified herein whichever is more strict. B. The contractor shall comply with the requirements of the General Conditions, Supplemental General Conditions of the project specifications, all Contract Documents, and any base building specifications and building criteria included in this project. C. Visit the premises before submitting bid as no extras will be allowed for lack of knowledge of existing conditions. D. Drawings are diagrammatic in nature. Take all dimensions from Architectural drawings, certified equipment drawings, and from the structure itself before fabricating any work. E. The drawings indicate the location, type and sizes of various utilities within the site where known. Any relocation or remodeling required must be approved by the Architect before proceeding. Investigate all utilities such as electric and telephone and make arrangements with the proper authority to pay for any charges associated with connecting those utilities. Pay for all permits, fees, inspections etc. F. Good workmanship and appearance are considered equal to proper operation. G. Provide all core drilling, channeling, cutting, patching, trenching and backfill as required for installation of electrical equipment. Seal holes, fireproofing where necessary, and refinish all repair work to original condition where damaged by electrical work. H. Make provisions for safe delivery and secure storage of all materials. I. Provide the Architect with a complete set of plans and specifications corrected to as -built conditions at the completion of the job. 12 WARRANTY The electrical contractor shall provide for the owner a one -year (from the date of final acceptance) warranty of all electrical equipment and systems provided under this contract except for incandescent or fluorescent lamps. All defective equipment or materials which appear during the warranty period shall be replaced or repaired by the electrical contractor in ❑ timely fashion. PART 2 PRODUCTS 21 EQUIPMENT A. The contractor shall provide all equipment, accessories necessary whether specifically stated or not to make the required electrical systems complete and operational. B. All equipment provided shall be new except as otherwise stated on the drawings. All equipment provided shall be U.L. listed when such standards exist for the type of equipment furnished and acceptable for installation by the Local Building Authority. 2.2 CONDUCTORS A. Minimum size #12 AWG except for control circuits which may be #14 or signal circuits which shall be as indicated. All conductors shall be copper. Increase conductor size as necessary to limit branch circuit voltage drop to 3% and feeder voltage drop to 2 %. B. Splices for #8 and C. Feeders and other D. Other wiring No. 6 smaller conductors - wire or wing nuts. wiring No. 4 AWG and larger, type THWN. and smaller, type THWN. E. Wiring in high temperature areas shall be rated 105•C and be a type accepted by local code. F. Color Coding: Wiring for control systems to be installed in conjunction with mechanical and miscellaneous equipment shall be color coded in accordance with the wiring diagrams furnished with the equipment. Branch circuit wiring, including circuits to motors, and all feeders shall be coded by line or phase as follows: B. C. Wire No. 2 AWG and smaller shall be factory color coded. Wire No. 1 AWG and larger may be color coded by field painting or color taping of six inch (6 ") length of exposed ends. 120/208 Volts 277/480 Volts A = Black A = Brown B = Red B = Orange C = Blue C - Yellow Neutral = White Neutral = Gray Ground = Green Ground = Green w /yellow strips Switch Travelers = Pink Switch Travelers = Purple 23 OUTLETS A. 4" square or octagonal, zinc coated sheet steel boxes. Provide 3/8" no -bolt fixture studs. Provide covers set to come flush with finish walls. D. Utility or sectional switch boxes only where permitted. 2.4 DEVICES A. All devices shall be ivory color. 1. Specification grade receptacles, Hubbell 5262 -I. 2. A.C. quiet operating type switches equal to Hubbell, rated 20A, 277V. B. Device plates shall be satin stainless steel, as manufactured by Sierra. C. Mount devices in accordance with the following schedule except where otherwise noted on the drawings: 1. Convenience Receptacles - Long Axis Horizontal 1'6" A.F.F.* 2. Light Switches - Latch Side of Door 4'0" A.F.F. 3. Telephone Outlets 1'6" A.F.F.* * Except in areas with counters, baseboard heaters or in areas of block or brick construction. 2.5 LIGHTING FDCTURES A. Provide all new lighting fixtures complete with lamps, ballasts, reflectors, plaster frames, louvers, stem hangers, etc., and as described on the drawings. B. Provide HID fixtures with multi -tap ballast. C. All ballasts shall be internally protected by use of two internal, temperature - sensitive, non - resetting protectors, equal to G.E. Watt- Miser, Class "P ". D. Exit lights shall conform with local code requirements. E. Mount all outlets at position and height to clear ducts, etc. F. Acrylic lenses shall be 100% virgin materials and 0.125 inch thick minimum unpenetrated thickness shall be 0.035 inch. 26 BRANCH CIRCUIT PANELBOARDS A. Provide dead - front, circuit breaker type panels, with the size and number of branches indicated. Breakers shall be thermal magnetic type (bolted) employing quick -make and quick -break mechanisms for manual operation as well as automatic operation. Automatic tripping shall be indicated by the breaker handle assuming a distinctive position from the manual "on" and "off ". Multiple breakers shall have a common trip. Tie handles will not be permitted. B. Panelboards having branch circuit breaker sizes 15 to 100 amperes shall be: 1. General Electric "AQ" for operation on 120/208V. systems. 2. General Electric "AE" for operation on 277/480V. systems. C. Panelboards may contain two (2) subfeed breakers having a rating in excess of 100 amperes, but less than 225 amperes. D. Panelboards having more than two (2) branch circuit breakers rated in excess of 100 amperes shall be General Electric "CCB ". E. All spaces shall be fully equipped. F. Panelboards shall have a grounding lug for the equipment grounding system. G. Circuit breakers shall have a minimum interrupting capacity as follows: 120/208 volts: 10,000 amperes. 277/480 volts: 18,000 amperes. H. Panelboards shall be a minimum twenty inches (20 ") wide (box). I. All buses shall be copper. J. The above panelboard designations are General Electric; however provide any of the following equipment, or as accepted: 120/208V 277 /480VSub- distribution type Cutler Hammer CHB NFB MP -40 General Electric AQ AE CCB I.T.E. CDP -7 CDP -7 CDP -6 Square -D NQOB NEHB I -Line Westinghouse WEB WEHB CDP 2.7 SAFETY AND DISCONNECT SWITCHES Provide enclosed, fusible or non - fusible safety switches where indicated and herein specified. Safety switches shall bear the UL label and each enclosure shall be the NEMA type suitable for the surrounding area and conditions. Switches shall be minimum heavy duty, horsepower rated, and shall have quick -make and quick -break mechanisms. Switches used on motor circuits shall have adequate horsepower ratings for the motors served. 1. Safety switches employed as motor disconnect devices for two (2) or more loads shall be of the fusible type for rejection type fuses. 2. Heavy duty industrial type safety switches shall be used for 480 volt application and shall be horsepower rated with quick -make, quick -break mechanisms and interlocked covers. 3. Switches shall be as manufactured by Cutler- Hammer, General Electric, Square -D, Westinghouse, or as accepted, and all switches provided shall be by the same manufacturer. 28 FUSES A. Fuses shall be as manufactured by Bussmann unless noted otherwise on the drawings. B. Fuses for application at under 600 volts, and rated at 600 amps or less, shall be as follows: 1. For all fuses in the main service, equipment, except for motor circuits, provide current limiting, 200,000 rms amperes symmetrical interrupting capacity, rejection type, Bussmann Limitron or as accepted. 2. For all other fuses, provide rejection type with 200,000 rms amperes symmetrical interrupting capacity, Bussmann "Fusetron ", or as accepted. C. Control Fuses shall be Bussmann one -time nonrenewable fuses. 29 DRY TYPE TRANSFORMERS OF APPLICABLE) A. ACCEPTABLE MANUFACTURERS 1. Square D 2. GE - Type QL 3. Cutler- Hammer - CX6 4. Alternate manufacturers may be acceptable when submitted according to Division 0 or Division 1. B. Dry Type Transformers: ANSI /NEMA ST 20; factory - assembled, air cooled dry type transformers; ratings as shown on the Drawings. C. Insulation system and average winding temperature rise for rated KVA as follows: Rating 1 - 15 16 - 500 Class 185 220 Rise (degree C) 115 115 D. Case temperature shall not exceed 35 degrees C rise above ambient at its warmest point. E. Winding Taps, Transformers Less than 15 KVA: Two 5% below rated voltage, full capacity taps on primary winding. F. Winding Taps, Transformers 15 KVA and Larger: ANSI /NEMA ST 20. G. Sound Level: ANSI /NEMA ST 20. H. Basic Impulse Level: 10 KV for transformers less than 3D0 KVA, 30 KV for transformers 300 KVA and larger. I. Ground core and coil assembly to enclosure by means of a visible flexible copper grounding strap. J. Mounting: Transformers 75 KVA and less shall be suitable for wall, floor or trapeze mounting; transformers larger than 75 KVA shall be suitable for floor or trapeze mounting. K. Coil Conductors: Continuous winding with termination's brazed or welded. L. Encloseure: ANSI /NEMA ST 20; Type 1 for indoor application, Type 3R for outdoor or wet location application. Provide lifting eyes or brackets. M. Isolate core and coil from enclosure using vibration - absorbing mounts. N. Nameplates: Include transformer connection data and overload capacity based on rated allowable temperature rise. PART 3 EXECUTION 3.1 CONDUIT /RACEWAYS A. All conductors shall be enclosed by conduit sized in accordance with Table 3C of the National Electrical Code. Minimum 1/2" except for factory furnished lighting fixture flexible conduit may be 3/8 ". Follow the following schedule unless otherwise specified in the drawings. 1 Galvanized rigid conduit (GRC) and intermediate metal conduit (IMC) shall be utilized for above and below grade applications in accordance with articles 345 AND 346 of the National Electrical Code. All couplings shall be threaded. 2. Rigid nonmetallic conduit (PVC) Schedule 40 shall be permitted for below grade or concrete cast in place applications above grade. All elbow transitions to above grade or stub -out of floor slab shall be asphalt coated rigid conduit. Provide equipment grounding conductor for all runs of rigid nonmetallic conduit. 3. Electrical metallic tubing (EMT) shall be utilized for all dry, above grade or above floor applications in accordance with article 348 of the National Electrical Code. Couplings shall be steel compression type made up wrench - tight. 4. Flexible metal conduit shall be utilized for all connections to vibrating equipment such as motors (minimum of 2' -0" - maximum of 6' -0 "), connection to lay -in type light fixtures or in remodel areas specifically noted for "fishing" in existing walls or non - accessible ceilings. 5. Surface metallic raceways shall be used only in areas specifically noted and of size and type specified on the drawings. B. All exposed conduit (including conduit installed in ceiling plenums) shall be routed parallel or perpendicular with the building walls. Support conduit as required by the National Electrical Code. C. Provide expansion type fittings for all conduits which cross expansion joints. 3.2 GROUNDING 1. Service equipment, conduit systems, supports, cabinets, equipment, transformers, fixtures, the grounded circuit conductor, etc., shall be properly grounded in accordance with the latest issue of the National Electrical Code. Provide all bonding jumpers and wire, grounding bushings, clamps, etc., as required for complete grounding. Route ground conductors to provide the shortest and most direct path to the ground electrode system. Ground connections shall have clean contact surfaces, tinned and sweated while bolting. Install all ground conductors in conduit. Make readily accessible connections to a continuous, metallic, underground cold water piping system at the point where it enters the building. If this is not practicable, connect to a cold water pipe and provide a meter jumper. Make connections to the water pipe that grounds the conduit enclosing the conductor as well as the conductor. Bond the service equipment to a separate grounding electrode per Code requirements. 3,3 PANELBOARDS 1. Install panelboards with the top of the trim six -feet, three- inches (6' -3 ") from the finished floor. 2. Field check all panelboard loading and reconnect circuits as required to provide balanced phase and line loads. 34 MECHANICAL EQUIPMENT WIRING AND CONNECTIONS 1. Mechanical equipment motors and controls furnished with mechanical equipment. 2. Provide feeder circuits to mechanical equipment and make all connections. 3. Provide safety switches and /or thermal overload switches as required. 4. Provide all power (line voltage) wiring for mechanical equipment and make all connections except for temperature control equipment, which will be wired by mechanical contractor. 5. Furnish, set in place, and wire, except as indicated, all heating, ventilating, air conditioning, plumbing, fire protection, motors and controls in accordance with the following schedule. Carefully coordinate with work performed under the Mechanical Division of these specifications. 6. Heater units in all motor starters shall be sized for approximately one hundred fifteen percent (115 %) of full load motor current. Check and coordinate all thermal protective devices with the equipment they protect. a) Provide for each motor, one -half (1/2) horsepower and below, a horsepower rated disconnect switch and thermal overload protection unless integrally provided with the motor. Thermal overload switches for single phase motors shall be Allen- Bradley Bulletin 600 or acceptable. Size heater units for approximately one hundred fifteen percent (115 %) of full load motor current. b) Miscellaneous Equipment: Where outlets are indicated for miscellaneous equipment requiring electric power or control, provide wire, conduit, etc., and make all connections, unless otherwise indicated. Refer to the Mechanical Specifications and Plans covering sprinkler systems, motor interlocks, switching, etc. Provide wiring, conduit, outlets and provide final electrical connections to all equipment. 3.6 DRY TYPE TRANSFORMER INSTALLATION OF APPLICABLE) 1. Set transformer plumb and level, on 4 in. high concrete housekeeping pad for floor mounted units, on strut assemblies for wall or ceiling mounted units. 2. Use flexible conduit 2 ft minimum length, for connections to transformer case. Make conduit connections to side panel of enclosure. 3. Mount transformers on vibration isolation pads suitable for isolating the transformer noise from the building structure. 4. Provide seismic restraints. 5. Install nameplate. 3.7 TELEPHONE SYSTEM A. Provide conduits and outlets as indicated. Provide #14 AWG pull wire for all empty conduit. B. Outlets shall consist of 4" square box with bushed opening in plate. Plates shall match finish of other plates. 3.8 SPECIAL SYSTEMS 1. Provide all special systems as specified on the drawings including all required accessories to make the system complete and operational. All special systems shall be installed and connected in accordance with the manufacturer's specifications. Provide instructional demonstration for the owner prior to final acceptance. END OF SECTION RECEIVED erry OF T' IKWILA JAN - 2 2000 - ERIVIl1 CENTER PANDA RESTAURANT GROUP, INC. Contact Person: Jerald Earl 1683 WALNUT GROVE AVE. ROSEMEAD, CALIFORNIA 91770 Direct: 360.885.1 135 Telephone: 626.714.8971 Facsimile: 626.372.8310 PROPERTY OWNER: WIG PROPERTIES LLC -SS 4811 134TH PL SE BELLEVUE, WA 98006 THESE DRAWINGS, DESIGNS, SKETCHES. IDEAS. ARRANGEMENTS AS WELL AS ANY AND ALL ELECTRONIC FILES AND /OR DWGS ARE THE SOLE AND EXCLUSIVE PROPERTY OF PANDA RESTAURANT GROUP INC. & VIGEN ARCHITECT. THESE PLANS WERE CREATED AND DEVELOPED BY AND FOR THE ARCHITECTS WORK. NOTHING CONTAINED OR REPRESENTED ON THESE DOCUMENTS SHALL BE USED BY OR DISCLOSED TO ANY PERSON. FIRM OR CORPORATION FOR ANY PURPOSE WFFHOUT THE EXPRESSED WRITTEN CONSENT OF PANDA RESTAURANT GROUP. INC. & VIGEN ARCHITECT. THE WORK CONTAINED ON THESE DWGS AND DOCUMENTS IS CREATED ONLY FOR THIS PROJECT AT THIS TIME AND NO OTHER. AND NOT FOR OTHER RELATED. IMPLIED. OR FUTURE WORK(S) OR PROJECT(S), ■ REVISIONS: • • ISSUE DATE: • 1ST 2ND 3RD 4TH 5TH 6TH • ARCHITECT • VIGEN ■ PROJECT: • PANDA EXPRESS "SOUTHCENTER MARKETPLACE" 17100 SOUTH CENTER PARKWAY TUKWILA, WA PANDA PROJECT #: S4- 08 -D167 ARCH PROJECT #: H702.020 DATE #: 8/25/07 THESE DRAWINGS TO BE USED ONLY FOR THE PROJECT LOCATED ABOVE. %1AN VIGEN WASHINGTON ARCHITECT A R C H I T E C T U R E& P L A N N I N G 1127 E. Olive Avenue Fresno, CA 93728 Phone: 559.268.2711 Fax: 559.268.1172 Web: www.vigen.com ADDENOUM SUBMITTAL 12/18/07