Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL07-583 - WESTFIELD SOUTHCENTER MALL - SEPHORA
SEPHORA 616 SOUTHCENTER MALL ELO7-583 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: City f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 616 SOUTHCENTER MALL TUKW SEPHORA 616 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA TIM SCHENK 1120 E 80 ST, STE 211 , BLOOMINGTON MN Contractor: Name: ABACUS ELECTRIC LLC Address: 9804 SALES RD S STE A -1 , LAKEWOOD WA Contractor License No: ABACUEL967DA DESCRIPTION OF WORK: ELECTRICAL FOR NEW TI Value of Electrical: $25,000.00 Fees Collected: $615.00 Type of Fire Protection: SPRINKLERS /AFA National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complied Signature. doc: EL -4/07 ELECTRICAL PERMIT Permit Number: ELO7 -583 Issue Date: 03/13/2008 Permit Expires On: 09/09/2008 Phone: Phone: 800 541 -0821 Phone: 253 -984 -1611 Expiration Date: 03/01/2010 Date:` 12 JV ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performan of work. I am authorized to sign and obtain this electrical permit. Date: 3 — / ` `-C> Print Name: / A- © /Cc 77 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. EL07 -583 Printed: 03 -13 -2008 Parcel No.: 6364200010 Address: 616 SOUTHCENTER MALL TUKW Suite No: Tenant: SEPHORA 1: ** *ELECTRICAL * ** Signature: Print Name: doc: Cond -Elec City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: ©? - 73 -6 8' f'1pr ,e ooc LLC_ TU Permit Number: ELO7 - 583 Status: ISSUED Applied Date: 10/12/2007 Issue Date: 03/13/2008 EL07 -583 Printed: 03 -13 -2008 King Co Assessor's Tax No.: N itst e Site Address: � OuT Suite Number: I 1 'Se Floor: Tenant Name: —r 4449 IZ-/(- New Tenant: 51 Yes ❑..No Property Owners Name: "' 6012- Poitiv l oral 044 Mailing Address: 1160 bvb LJ1 -146 Cs "17 1 LoO (-.'t 4446c1--rd. ( 44- 16°24-- Cit Name: Mailing Address: E -Mail Address: Company Name: Mailing Address: V CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** State Zip CONTACT PERSON =Who do we contact when your permit is ready to he issue 1'1n f alst Day Telephone: 011 1 0$ 2-1 'zo 5 SON 41 t7vifl &t 4 TVN i , ,TSB -* (n City State Zip +14%-f @ P/lGC'Prr'J OJT` • cd-iw. Fax Number: 6rz $r4 41-01 State Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ " O'VV Scope of Work (please provide detailed information): atali&A Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Type of work: a_New ❑ Addition ❑ Service Change ❑ Remodel 3:4, Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H:1Applications\Forms- Applications On Line\4 -2007 - Electrical Permit Application.doc bh Page 1 of 2 ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: I Date Application Accepted: IL\Applications\Formts- Applications On Line\4 -2007 - Electrical Permit Application.doc bh Date Application Expires: MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOT Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. tee aVierr Pkiernir JeRe Date: C0Z1(7— rn sruiVek Day Telephone: 1 13 'r/ 0E4 Mailing Address: No Son/ i .1 t ill 8 14VM0/ K S j T1 City State Zip MISCELLANEOUS FEES Page 2 of 2 n,.... ornermc nc RECEIPT NO: R08 -01368 SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us Copy Reprinted on 04 -28 -2008 at 15:26:02 04/28/2008 Initials: JEM Payment Date: 04/28/2008 User ID: 1165 Total Payment: 116.00 Payee: CUMMINGS CONTRACTORS, INC. SET ID: 0428 SET NAME: Temporary Set EL07 -583 58.00 M07 -220 58.00 TOTAL: 116.00 TRANSACTION LIST: Type Method Description Amount Payment Check 398 116.00 TOTAL: 116.00 ELECTRICAL PERMIT - NONR MECHANICAL - NONRES SET RECEIPT Account Code Current Pmts 000.322.101.00.0 58.00 000/322.100 58.00 TOTAL: 116.00 1690 04/28 9711 TOTAL 116.00 Receipt No.: R08 - 00734 Payee: ABACUS ELECTRIC, LLC ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Payment Check 14859 492.00 TRANSACTION LIST: Type Method Descriptio Amount RECEIPT Parcel No.: 6364200010 Permit Number: EL07 -583 Address: 616 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 10/12/2007 Applicant: SEPHORA Issue Date: Initials: JEM Payment Date: 03/13/2008 09:30 AM User ID: 1165 Balance: $0.00 Account Code Current Pmts 000.322.101.00.0 492.00 Total: $492.00 Payment Amount: $492.00 9 03/13 `?710 TOTAL 492.0; tint.! Raraint -nR Printac17 03- 13 -70f1R Doc: RECSEZS -06 RECEIPT NO: R07 -02245 User ID: 1165 Payee: ELDER -JONES SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT Initials: JEM Payment Date: 10/12/2007 Total Payment: 1,587.10 SET ID: S000000876 SET NAME: Tmp set/Initialized Activities D07 -386 1,342.11 EL07 -583 123.00 M07 -220 82.49 PG07 -274 39.50 TOTAL: 1,587.10 TRANSACTION LIST: Type Method Description Amount Payment Check 50014 1,587.10 TOTAL: 1,587.10 ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES Account Code Current Pmts 000.345.832.00.0 123.00 000/345.830 1,464.10 TOTAL: 1,587.10 TO Proj a J n , Type of Inspectio e7 v r A z: M t nn Date Called: Special Instructions: Date Wanted: // / / m. er Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPE ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 a 07 PERMIT NO. LI Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: (9/e- r lIns c trre I Date / k f $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. J Receipt No.: 'Date: (206)431 -3670 COMMENTS: 9 Ac, f /Xwes mrts r 7-///: / uL f4 /' fL x}71 #l(/ -/z 'P// UNIT f'T 7W' mc_7 -- 7 Date Called: & y f/� t- A vm-1/A i /1A/ pfry /Mk /9cc /55 FM //f/1/ ic /c-4770X Of 1-144 s & Paving f /124 61,1 4PM 114 Uf 4 6 S.f G /G'JT //1/c ' a. J . m. Requester: Phone No: Project ^ �/Z /4 Type of Inspection:. A dre s: , /h �uril irtrx..�f Ai, Date Called: Special Instructions: Date Wanted: t / / 2 ' a. J . m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION _ 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (06)431 -3670 407- CrC., ❑ Approved per applicable codes. I2rrections required prior to approval. (inspect oeT p ��/� `Date: & /� $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: COMMENTS: ,O/ Type of Inspection: -- (-/4//1G 6 - 0 (/<, ( -- /%44 1)46,15 - G /Z //) Special Instructions: Date Wanted: frA � Requester: iUoi "- j - fix nat s 41I/sT' - k-greA /WA L4,e GS Project 6 4 Type of Inspection: -- A dress: /lam 501/17/�, f r'/ 'lk. Date Called: Special Instructions: Date Wanted: frA � Requester: Phone No: 7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION r 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. Approved per applicable codes. Corrections required prior to approval. I lnspect o i1 L grorAg F 58 INSPECTION RECORD Retain a copy with permit $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Pro !afg-072 4 Type of Ins ection: Addre AA fArg4 / k W Date Calle : - - Instructions: Spicial Inst Date Wanted: a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 OMMENTS: 44- cp1ift16- _< 2 1/ :I proved per applicable codes. El Corrections required prior to approval. Ins t TEA I/01 I Dat V 8 0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: - Projg :6 n Type of Inspection: �� A dr e piwei/v / Date Called: SpecialJ\nstructions: Date Wanted: 9 i a Requester: Phone No: ii407- Sr? INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION e 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 OMMENTS: cAtf.0 f9 41/ 9 4_1(cz ✓f/ x 40c/9770/vs proved ncATia/vs proved per applicable codes. Corrections required prior to approval. I fa.' , lU r El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit Proje; AM " Type of Inspection: A ire s : l urHcf t Mfg, Date Called: Special Instructions: Date Wanted: �// C. p.m. Requester: Phone No: b fko -S'3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: - c X - • roved per applicable codes. Corrections required prior to approval. (Inspr f4/72/4/1C// • .t- (Date: y /6lw El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: P Z 1 fP ect: -fi&A/q Type of Inspec tion: -. 200 ssl cin tow A tt. r1/7Date Called: Special Instructions: Date Wanted: Requester: Phone No: 3 14 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION i 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 COMMENTS: 6.5 0 - sawct (*ea 77e4A 011-c-ea-/A16- -Motr X7. S791 l Inspectoi2 pproved per applicable codes. Corrections required prior to approval. a tirtametii 'Date: 0 / $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Pro!saap A. Type of Inspection: - 7003 \... Address: Date Called: Special Instructions: Date Wanted: CM) P.m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1-07-SK7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 44 ' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-36 COMMENTS: rn X-/4/9/,(, 64142 crock MO/4 0 fc/c 's 19AcrKtivin -//4/U J./ A5 proved per applicable codes. E1 Corrections required prior to approval. rsPAilit ,,4/71My6// IDate:Wohe $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Prgject: 54.4 Type of Inspection: 70/ At zs: 4Date Called: Special Instructions: Date Wanted: 7/ . - Ca P.m. Requester: Phone No: INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 OMMENTS: og s Inspe INSPECTION RECORD Retain a copy with permit roved per applicable codes. El Corrections required prior to approval. Jtit (477X10//C Date: 7/ 2 r $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection._ 'Receipt No.: 'Date: Project Info Project Address 633 SOUTHCENTER rtALL Date 10/4/2007 SUITE 1120 For Building Department Use TUKWILA, WA 98118 Applicant Name: Sephora Applicant Address: 525 WARICET STREET Applicant Phone: SAN FRANCISCO, CA 94105 2006 Washington State Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms FILE COPY OCT 0 it 2007 CPA ' r. . 4„ 01A.,1__, •Y i Revised July 2007 RECEIVED CITY OF TUKWILA OCT 12 2007 PEFi vtil CEWTEi Project Info Project Address 633 SOUTHCENTER MALL Date 10/4/2007 SUITE 1120 For Building Department Use TUKWILA, WA 98118 Applicant Name: sephora Applicant Address: 525 MARKET STREET Applicant Phone: SAN FRANCISCO, CA 94105 Project Description ❑ Plans Induded requirements. '1 New Building ❑ Addition ❑ Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive O Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting III Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) Occupancy Description Allowed Watts per ft Area in ft Allowed x Area Area f1 Retail 1.50 5439.0 8158.5 Area #1 Note 10: FA -1 1.50 5439.0 8158.5 Area #1 WALL SHELF (EXEMPT SECTION 1512.2, NUMBER 3) 66 " From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 16317.0 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Area #1 FA -1 (TRACK 480watt current limiter) 3 480.0 1440.0 Area #1 FA -1 (TRACK 960watt current limiter) 6 960.0 5760.0 Area #1 WALL SHELF (EXEMPT SECTION 1512.2, NUMBER 3) 66 Area 11 GONDOLA (EXEMPT SECTION 1512.2, NUMBER 3) 26 Area 11 G3 (FLUORESCENT, T5, 2 LAMPS, ELECTRONIC) 1 25.0 25.0 Area 11 FJ (FLUORESCENT, F32T8, 1 LAMP, ELECTRONIC) 62 32.0 1984.0 Area i1 FT (FLUORESCENT, F32T8, 3 LAMPS, ELECTRONIC) 4 64.0 256.0 Area 11 FU (FLUORESCENT, F32T8, 1 LAMP, ELECTRONIC) 21 32.0 672.0 Area 11 WW (METAL HALIDE, 39WATT T6, 1 LAMP, ELECTRONIC) 37 44.0 1628.0 Area 11 FA -1 (TRACK 720watt current limiter) 5 720.0 3600.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 15365.0 Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Maximum Allowed Lighting Wattage Proposed Lighting Wattage 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. Use LPA` (W /sf) Use' LPA (W /s° Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) , 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations 1.0 Cafeterias, fast food establishments restaurants/bars 1.3 Post office 1.1 Dormitory 1.0 Retail retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia", assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1 Hotel/motel 1.0 Warehouses ", storage areas 0.5 Hotel banquet/conference/exhibition hall 2.0 Workshops 1 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0 Laundries 1.2 Libraries5 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum Pnn4nn4ne fns Tahre 4C_ 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) . 2006 Washington State Nonresidential Energy Code Compliance Forms LTG -INT Revised July 2007 Prescriptive Spaces Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Occupancy: O Warehouses, storage areas or aircraft storage hangers 0 Other Lighting Fixtures: (Section 1521) ❑ Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T-8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft 1) 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w/ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Project Info Proj Addres: SOUTHCENTER MALL Date 10/4/2007 Area (ft), perimeter (It) or # of items SUITE 1120 For Building Department Use TUKWILA, WA 98118 Name: sephora Appl. Name 525 MARKET STREET Appl. Phone s» FRMCISCo, CA 94105 Project Description ❑ N ❑ Addition ❑ Alteration ❑ Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. 1 Compliance Option I Q Lighting Power Allowance 0 Systems Analysis I Building Grounds (luminaires > 100 Watts) • Efficacy > 60 lumens/W ❑ Controlled by motion Sensor ❑ Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Tradable Locations Description Allowed Watts per ft or per If Area (ft), perimeter (It) or # of items Allowed Watts x ft2 (or x if) J •�,_.._ __ _.. _ _. • Non - Tradable Locations Description Allowed Watts per ft or per If Area (ft perimeter (If) or # of items Allowed Watts x ft (or x If) J •�,_.._ __ _.. _ _. • Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed J •�,_.._ __ _.. _ _. • Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary LTG -EXT 2006 Washington State Nonresidential Energy Code Compliance Forms Tradable Maximum Allowed Lighting Wattage Tradable Proposed Lighting Wattage o Allowe W atts for Exterior Non - Tradable Maximum Allowed Lighting Wattage Non - Tradable Proposed Lighting Wattage y not exceed Allowed Watts for Category Total Allowed Watts Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. Total Proposed Watts Tradable Surfaces (Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded.) I Uncovered Parking Areas Parking lots and drives 1 0.15 W/ft Building Grounds Walkways less than 10 feet wide 1.0 W/linear foot Walkways 10 feet wide or greater plaza areas Special feature areas 0.2W/ft Stairways 1.0 W/ft Building Entrances and Exits Main entries 30 W/linear foot of door width Other doors 20 W/linear foot of door width Canopies and Overhangs Canopies (free standing and attached and overhangs) 1.25 W/ft Outdoor Sales Open areas (including vehicle sales lots) 0.5 W/ft Street frontage for vehicle sales lots in addition to "open area" allowance 20 W/linear foot Non - Tradable Surfaces (Lighting power density calculations for the following applications can be used only for the specific application and cannot be traded between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in the "Tradable Surfaces" section of this table.) Building Facades 0.2 Wife for each illuminated wall or surface or 5.0W/linear foot for each illuminated wall or surface length Automated teller machines and night depositories 270 W per location plus 90 W per additional ATM per location Entrances and gatehouse inspection stations at guarded facilities 1.25 W/ft of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces ") Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W/ft of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces ") Material handling and associated storage 0.5 W /ft Drive -up windows at fast food restaurants 400W per drive- through Parking near 24 -hour retail entrances 800 W per main entry 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary (back) 2006 Washington State Nonresidential Energy Code Compliance Forms LTG -EXT TABLE 15 -2 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS Revised July 2007 2006 Washington State Nonresidential Energy Code Compliance Form Lighting Power Allowance Adjustments 2006 Washington State Nonresidential Energy Code Compliance Forms LTG -LPA Project Address 1633 633 30i7THCENTER MALL 'Date Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15-1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft Carry the Adjusted LPA to the corresponding Allowed Watts per ft location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor /room no.) " From Table 15 -1 based on exceptions listed in footnotes Revised July 2007 Occupancy Description Allowed Watts per ft Ceiling Height for this room Ceiling Height limit for this exception" Adjusted LPA Watts per ft2 • tg ting, Motor, 2006 Washington State Nonresidential and Transformer Permit Plans Checklist LTG -CHK Energy Code Compliance Forms Revised July 2007 Project Address 633 SOUTHCENTER MALL I Date 10/4/2007 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) I Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yH 1513.1 Local control/access Schedule with type, indicate locations yes 1513.2 Area controls Maximum limit per switch n.a. 1513.3 Daylight zone control Schedule with type and features, indicate locations n.a. vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location n.a. (a) timer w/backup Indicate location n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans yes 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes I 1514 'Max. watts 'Indicate (Section watts for each exit sign I 1530 -1532) I LIGHTING POWER ALLOWANCE yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture n.e. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) yes I 1511 IElec motor efficiency'MECH -MOT or Equipment Schedule with hp, rpm, efficiency I I TRANSFORMERS (Section 1540) yes I 1540 'Transformers 'Indicate size and efficiency I I 2006 Washington State Nonresidential Energy Code Compliance Form no is c i rc l e d f or any question, provide explanation: 2006 Washington State Nonresidential Energ Code Compliance Form Lighting; Motor, and Transformer Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant - sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1613.6 Automatic Shut -Off Controls, Interior. Buildings greater than 5,000 ft and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of turning off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting tc remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft or 5% of the building footprint for footprints over 100,000 ft whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP -1- 2002). 03 -05 -2008 TIM SCHENK 1120 E 80 ST, STE 211 BLOOMINGTON MN 55420 RE: Permit Application No. EL07 -583 616 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 10/12/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 04/09/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 04/09/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: er Marshall it Technician Permit File No. EL07 -583 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: EL07 -583 DATE: 04 -10 -08 PROJECT NAME: SEPHORA SITE ADDRESS: 616 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 'I After Permit Issued DEPARTMENTS � Bug U�risi'n jle Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete [O Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Structural Structural Review Required APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Documents/routing slip.doc 2 -28-02 Fire Prevention Planning Division ❑ Permit Coordinator DUE DATE: 04-15-08 ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 05 -13 -08 x Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: EL07 -583 DATE: 10 -12 -07 PROJECT NAME: SEPHORA SITE ADDRESS: SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: G i I V Buil m Ivlslon Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete VI Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 ' PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural ❑ ❑ Permit Coordinator DUE DATE: 10-16-07 Not Applicable El No further Review Required DATE: Planning Division n CI DUE DATE: 11 -13-07 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 I-k o .-oR U4L 0 `tirt Pi? Summary of Revision: Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 I-k o .-oR U4L 0 `tirt Pi? Summary of Revision: Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 I-k o .-oR U4L 0 `tirt Pi? Summary of Revision: Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 I-k o .-oR U4L 0 `tirt Pi? Summary of Revision: Summary of Revision: v i ge, Lo \iii4f.41 t. 10 i d1 vkc S reCS I b{ t 4 64 K, V ck 'k \ (4lM ) 1\ i `t' 1 able_ c WkuA P Ir. ciNtSA.)1-e j Received by: it/Cke Cv , ky. • ° s , . c, s REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: PROJECT NAME: Se p6r6C SITE ADDRESS: (p((o Soo4 cue kvter J & LI ORIGINAL ISSUE DATE: 3- 13-09 REVISION LOG PERMIT NO: E LO 583 (please print) (please print) (please print) (please print) (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 4 l 9 f O Plan Check/Permit Number: EL of - 5133 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # (r Revision # ( I after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: SE P14aRA Project Address: 6I6 Scdri-k .).- d'ri f / & i ? a SPnLkr:. 112O Contact Person: TL M S A k— Phone Number: 1 • S QO. 54 I •0 8 Summary of Revision: See AtTA(A4I U (T 'l. P(L(W\ 13riG Sheet Number(s): � 1.0 • ea.° E7 .0 • C 4:o t• t S.o "Cloud" or highlight all areas of revision including date of revisi Received at the City of Tukwila Permit Center by: "Entered in Permits Plus on 1 1 — . O U \ applications \forms- applications on Iine\revision submittal Created: 8 -13 -2004 Revised: Steven M. Mullet, Mayor Steve Lancaster, Director CITY TUKWILA APR 10 2008 QEAMIT,c ~ktv -rt_ a« License Information License ABACUEL967DA Licensee Name ABACUS ELECTRIC LLC Licensee Type ELECTRICAL CONTRACTOR UBI 602371073 Ind. Ins. Account Id Business Type LIMITED LIABILITY COMPANY Address 1 9804 SALES RD S STE A -1 Address 2 City LAKEWOOD County PIERCE State WA Zip 98499 Phone 2539841611 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/1/2004 Expiration Date 3/1/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License OUELLMR9605O Look Up a Contractor, Electrir;an or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Master Electrician Information License Name Status OUELLMR9605O OUELLETTE, MARK R ACTIVE Business Owner Information Name OUELLETTE, MARK R Role PARTNER/MEMBER Effective Date 03/01/2004 Expiration Date OUELLETTE, GARY B PARTNER/MEMBER 03/01/2004 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= ABACUEL967DA 03/13/2008 A\ 04 -03-08 REVISION JAH WPK & 03 -27 -08 REVISION JAH WPK L 03 -19 -08 REVISION RL MW /2\ 03 -14-08 REVISION JAH WPK 02 -01-08 ISSUE FOR BID JAH WPK / l \ 11 -12 -07 CITY COMMENTS RE- SUBMITTAL JAH WPK 10 -08-07 ISSUE FOR PERMIT JAH WPK 07 -27 -07 CLIENT /PRELIM. LL REVIEW JAH WPK Q DATE ISSUE DESCRIPTION BY CHECK 112.5KVA TRANSFORMER CLP PANEL "C" B -40 B -25/ 7 B-18 14 C -14,16 C -8 C 8 C -10 C -8 C -2,4,6 B -7 B -1 A -15 VAV -1 ENSOR C - 1 2 VAV -4 . SENSOR VAV -4 SENSOR BUILDING CORRIDOR I I PANEL "H" I B -10 B_ 8 B -14 LOW VOLTAGE WRING SPECIFICATIONS (USING CAT - 5 WIRING) 1 FROM CASHWRAP TO TEL /DATA TERMINAL BOARD - FOUR CABLES PER REGISTER LOCATION AND TWO SPARE (18 CABLES TOTAL PER TYPICAL 4 REGISTER CASHWRAP AND 28 CABLES TOTAL PER 6 SECTION CASHWRAP (4 SPARE)). A 20 FOOT SERVICE LOOP AT EACH CASHWRAP CONDUIT STUB IS REQUESTED. SEE DETAIL D SHEET E3.0. 2 FROM OFFICE LOCATION TO TEL/DATA TERMINAL BOARD— 5 INDIVIDUAL DROPS (4 CABLES PER DROP). (4) DROPS BELOW COUNTERTOP, (1) DROP ABOVE COUNTERTOP (GUEST PORT). A THREE FOOT SERVICE LOOP AT EACH DATA JACK IN OFFICE AND A 20' SERIVCE LOOP AT THE TEL /DATA TERMINAL BOARD. 3 FROM RECEIVING DESK LOCATION TO TEL /DATA TERMINAL BOARD- ONE DROP (FOUR CABLES PER DROP). A THREE FOOT SERVICE LOOP AT RECEIVING DESK LOCATION AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 4 FROM TIME AND ATTENDANCE DEVICE (BY OFFICE DOOR) TO TEL/DATA TERMINAL BOARD— ONE DROP (TWO CABLES PER DROP). A THREE FOOT SERVICE LOOP AT TIME AND ATTENDANCE LOCATION AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 5 FROM BURGLAR ALARM BOX TO TEL /DATA TERMINAL BOARD— ONE DROP (ONE CABLE PER DROP). A THREE FOOT SERVICE LOOP AT THE BURGLAR ALARM AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 6 FROM UGHTING CONTROL PANEL TO TEL /DATA TERMINAL BOARD ONE DROP (ONE CABLE PER DROP). A SIX FOOT SERVICE LOOP AT THE LIGHTING CONTROL PANEL LOCATION AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 7 FROM FIRE ALARM BOX TO TEL /DATA TERMINAL BOARD— ONE DROP (ONE CABLE PER DROP). A THREE FOOT SERVICE LOOP AT THE FIRE ALARM LOCATION AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 8 IF CONDUIT TERMINATES AT TELEPHONE TEL /DATA TERMINAL BOARD, A 20 FOOT SERVICE LOOP SHALL BE MEASURED FROM THE END OF THE CONDUIT. 9 IF CONDUIT DOES NOT TERMINATE AT TELEPHONE TEL /DATA TERMINAL BOARD, CABLE LENGTH SHOULD BE SUFFICIENT TO EXTEND TO THE MIDDLE OF THE BACKBOARD, THEN ADD A 20 FOOT SERVICE LOOP. 10 FROM FRONT DOOR HEADER ABOVE CEIUNG TO TEL /DATA TERMINAL BOARD— ONE DROP (2 CABLES PER DROP). A 25 FOOT SERVICE LOOP AND TIE OFF TO THE STRUCTURE FOR FUTURE PEOPLE COUNTER, AND A 20' SERIVCE LOOP AT TEL/DATA TERMINAL BOARD IS REQUESTED. 11 FROM SECURTIY (OVER SAFE) TO TEL /DATA TERMINAL BOARD— ONE DROP (4 CABLES PER DROP). A THREE FOOT SERVICE LOOP AT THE SECURITY END AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 12 LIGHTING CONTROL PANEL TO HAVE A DEDICATED PHONE UNE FOR REMOTE ACCESS. CONTRACTOR IS TO ROUTE A DEDICATED RJ -11 PHONE CABLE TO LC &D CONTROL PANEL AND MAKE THE TERMINATION. 13 HVAC CONTROL PANEL TO HAVE A DEDICATED PHONE LINE AND DATA UNE FOR REMOTE ACCESS. CONTRACTOR IS TO ROUTE A DEDICATED RJ-11 PHONE CABLE AND A DEDICATED RJ -45 CABLE TO HVAC CONTROL PANEL AND MAKE THE TERMINATION. NOTE: ALL CONDUIT AND WIRE MATERIALS TO BE PROVIDED BY ELECTRICAL CONTRACTOR. 5 n TYP O CODED NOTES: ® PROVIDE A DUPLEX RECEPTACLE, MOUNTED HORIZONTALLY AT 4" AF.F. FOR WINDOW DISPLAY. ® PROVIDE CONNECTION TO WALL MOUNTED DISPLAY UNITS. SEE DETAIL C, SHEET E3.0 FOR ADDITIONAL CONNECTION REQUIREMENTS. ® PROVIDE A JUNNCTION BOX FOR FUTURE PEOPLE COUNTER. PROVIDE A TWENTY FOOT :SERVICE LOOP OF CABLE AND TIE OFF TO THE STRUCTURE FOR FUTURE USE. 0 PROVIDE (1) 8 "X8" PULL BOX WITH (2) 1" CONDUITS STUB OUT ABOVE CEIUNG FOR SECURITY SYSTEM. PROVIDE PULL BUSHINGS ON CONDUIT ENDS AND PULL STRINGS IN EACH. MOUNT PULL BOX AT SAME HEIGHT AS RECEPTACLES AND PROVIDE (1) 2" NIPPLE BUSHING IN THE FACEPLATE. SEE DETAIL E, SHEET E3.0. FOR MORE INFORMATION. ® PROVIDE CONNECTION TO HOT WATER HEATER. COORDINATE LOCATION IN THE FIELD WITH PLUMBING CONTRACTOR. ® CONDUIT SAW -CUT OR CORE DRILLED IN FLOOR. VERIFY REQUIREMENTS FOR SAW - CUTTING OR CORE DRILLING WITH LANDLORD. ROUTE CONDUIT TO NEAREST ACCESSIBLE WALL AND RISE UP TO CEILING. ®7 PROVIDE DUPLEX RECEPTACLE AND DATA FOR EMPLOYEE TIME CLOCK. ® MASTER LIGHTING CONTROL PANEL. CONNECT TO CIRCUIT B -15. SEE SCHEDULE ON SHEET E5.0. ® PROVIDE RECESSED DUPLEX FLOOR RECEPTACLE AT GONDOLA. CENTER UNDER 3 SECTION AND THE 1 SECTION GONDOLAS. OFFSET UNDER 2 SECTION GONDOLA. ELECTRICAL CONTRACTOR TO PROVIDE CORD AND PLUG CONNECTION FROM CENTER J -BOX. PROVIDE CONDUIT AND WIRE CONNECTIONS BETWEEN MANUFACTURER SUPPLIED J -BOXES IN GONDOLA SECTIONS. CONTRACTOR IS TO VERIFY THE SLAB TYPE AND REFER TO DETAILS A AND H ON SHEET E3.0. GONDOLAS WITH MAKE -UP MIRROR WILL BE SUPPLIED WITH A WHIP THAT SHALL BE CONNECTED INTO THE JUNCTION BOX OF THE GONDOLA. COORDINATE WITH ARCHITECTURAL PLANS. •10 CONTRACTOR IS TO VERIFY THE USE OF A SIX SECTION OR A FOUR SECTION AND SEE "CASH WRAP CONDUIT AND WIRING" DETAIL D ON SHEET E3.0 FOR ELECTRICAL REQUIREMENTS AND CIRCUITING IN THIS AREA. ® PROVIDE A J -BOX FOR SECURITY MOTION DETECTOR. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH SECURITY INSTALLER. 12 LOCATION OF THERMOSTAT OR SENSOR. COORDINATE EXACT LOCATIONS, MOUNTING HEIGHTS AND QUANTITY WITH MECHANICAL AND ARCHITECTURAL PLANS. PROVIDE A JUNCTION BOX, MOUNTED HORIZONTALLY, AND STUB A 3/4" CONDUIT, WITH A PULL STRING, ABOVE THE CEILING FOR EACH DEVICE. 13 PROVIDE A DUPLEX RECEPTACLE MOUNTED BELOW SINK, FOR THE GARBAGE DISPOSAL. RECEPTACLE SHALL BE CONTROLLED BY WALL MOUNTED SWITCH. 14 TEL /DATA TERMINAL BOARD, SEE DETAIL B SHEET E3.0 FOR FURTHER REQUIREMENTS. LOCATE LUCENT CABINET IN UPPER CORNER OF PLYWOOD TERMINAL BOARD. 4 C- 3,5,23 15 MAINTAIN CLEARANCE FOR ELECTRICAL EQUIPMENT AS REQUIRED BY N.E.C. TABLE 110- 26(A)(1). 36" FOR 208V EQUIPMENT, AND 42" FOR 480V EQUIPMENT. 16 EF -1 AND EF-2: 120V, 10, 98W, PROVIDED BY HVAC CONTRACTOR. FAN SHALL BE CONTROLLED BY WALL MOUNTED OCCUPANCY SENSOR, PROVIDED BY ELECTRICAL CONTRACTOR. MAKE ALL FINAL CONNECTIONS. VERIFY EXACT LOCATION WITH HVAC CONTRACTOR. 17 LOCATION OF SECURITY KEYPAD. PROVIDE J -BOX AND CONDUIT BACK TO SECURITY PANEL. 18 APPROXIMATE LOCATION OF CEILING MOUNTED SECURITY CAMERA. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH SECURITY INSTALLER. ® DUCT SMOKE DETECTOR PROVIDED BY MECHANICAL CONTRACTOR. ELECTRICAL CONTRACTOR TO MAKE ALL FINAL CONNECTIONS. COORDINATE WITH LANDLORD FOR CONNECTION REQUIREMENTS. 20 PROVIDE SERVICE DOOR BUZZER SYSTEM INCLUDING TRANSFORMER, PUSH - BUTTON AND BUZZER. SEE DETAIL G ON SHEET E3.0 FOR MORE INFORMATION. 21 CEILING MOUNTED DUPLEX RECEPTACLE SHALL BE MOUNTED HORIZONTAL TO STOREFRONT AT 18" OFF OF STOREFRONT GLASS. 22 PROVIDE 120V 20A DEDICATED CIRCUIT FOR SIGNAGE. COORDINATE WITH SIGNAGE SUPPLIER FOR LOCATION AND ROUTING OF CONDUIT. IF SIGN IS IN AN EXTERIOR LOCATION, PROVIDE A WEATHERPROOF JUNCTION BOX. 23 MOUNT RECEPTACLE AT 86" A.F.F. FOR TELEVISION /DVD PLAYER. 24 MOUNT RECEPTACLE AT 21"± AFF. FROM CENTER OF BOX. RECEPTACLE SHALL BE CENTERED WITHIN COLUMN A BLACK OR WHITE STRIPE ON COLUMN. REFER TO ARCH DETAILS FOR COLOR REQUIRED. 3 ELECTRICAL POWER PLAN 1/4".1'-o" AIR TRANSFER FAN (TF -1): 120V, 10, 172W, PROVIDED BY MECHANICAL CONTRACTOR. VERIFY EXACT LOCATION WITH MECHANICAL DRAWINGS. TYP ELECTRICAL CONTRACTOR TO PROVIDE PULL BOX(ES) (SIZED PER NEC 314) FOR ALL POWER CIRCUITS FEEDING THE SALES FLOOR, INCLUDING BUT NOT LIMITED TO FLOOR BOXES, CASHWRAP, WALL DISPLAYS AND STORE FRONT RECEPTACLES. MOUNT BOXES AS HIGH AS POSSIBLE ON BACK OF HOUSE WALL. ALL HOMERUNS BACK TO PANEL ARE TO BE EMT. PROVIDE POWER AND DATA CONNECTIONS TO RECEIVING DESK. SEE DETAIL F, SHEET E3.0 FOR ADDITIONAL INFORMATION. 28 ELECTRICAL CONTRACTOR TO PROVIDE A CONTACTOR FOR RTU -4. CONTACTOR IS TO BE USED TO INSURE THAT RTU -3 AND RTU -4 WILL NOT SIMULTANEOUSLY OPERATE. REFER TO HVAC CONNECTION SCHEDULE, SHEET E5.0, FOR CONDUCTOR, CONDUIT AND OVERCURRENT SIZES. FIELD VERIFY EXACT LOCATION. 30 PROVIDE JUNCTION BOX FOR MOTOR OPERATED DUCT DAMPERS. COORDINATE EXACT LOCATION WITH HVAC CONTRACTOR. ADJACENT TENANT ADJACENT TENANT C -7,9 2 31 PROVIDE A DUPLEX RECEPTACLE FOR OWNER FURNISHED ILLUMINATED MIRROR. RECEPTACLE IS TO BE CONTROLLED VIA THE LIGHTING CONTROL PANEL AND MOUNTED AT 54" A.F.F. 32 CURRENT LIMITING PANEL SEE "CURRENT LIMITING PANEL DETAIL" SHEET E5.0. 33 APPROXIMATE LOCATION OF TEMPERATURE CONTROL PANEL. PROVIDE (1) RJ -11 AND (1) RJ -45 CONNECTION FOR TEMPERATURE CONTROL. SEE DETAIL B ON SHEET E3.0 FOR MORE INFORMATION. VERIFY EXACT LOCATION WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. 34 PROVIDE A DUPLEX RECEPTACLE, MOUNTED BELOW THE SINK, FOR THE INSTANT WATER HEATER. 0 , PROVIDE A SWITCH TO CONTROL UNDER COUNTER LIGHT. SEE SHEET E2.0 FOR MORE INFORMATION. 36 PROVIDE A 30A NEMA L5 -30R TWIST LOCK RECEPTACLE. O . ELECTRICAL CONTRACTOR TO FIELD VERIFY LOCATION OF LANDLORD PROVIDED FUSED DISCONNECT SWITCH BEFORE BIDDING, AND RELOCATE AS REQUIRED. SEE "RISER DIAGRAM ", SHEET E5.0, FOR MORE INFORMATION. 0 ELECTRICAL CONTRACTOR TO PROVIDE A 1" CONDUIT FROM THE MALL COMMINICATION CABLE TRAY, LOCATED IN THE SERVICE CORRIDOR, TO THE NETWORK CABINET. ANY CORRIDOR WALL PENETRATIONS MUST BE FIRE CAULKED AS REQUIRED. VERIFY EXACT LOCATIONS BEFORE BIDDING WORK. SEE "RISER DIAGRAM ", SHEET E5.0, FOR MORE INFORMATION. 0 FIRE ALARM CONTRACTOR SHALL PROVIDE CEILING /WALL MOUNTED AUDIO /VISUAL DEVICES AND INTERCONNECT DEVICES WITH LANDLORD'S CENTRAL FIRE ALARM SYSTEM. DEVICES SHALL BE COMPATIBLE WITH THE LANDLORD'S FIRE ALARM SYSTEM. ALL DEVICES SHALL BE WHITE. 0 LANDLORD TO PROVIDE J -BOX FOR INTERCONNECTION TO MALL FIRE ALARM SYSTEM. VERIFY EXACT LOCATION PRIOR TO ROUGH -IN. A LANDLORD APPROVED FIRE ALARM CONTRACTOR TO MAKE FINAL CONNECTION TO MALL FIRE ALARM SYSTEM. 41 FIRE ALARM CONTRACTOR SHALL PROVIDE SMOKE DETECTOR AND INTERCONNECT DEVICES WITH LANDLORD'S CENTRAL FIRE ALARM SYSTEM. ALL DEVICES SHALL BE WHITE. 0 , FIRE ALARM CONTRACTOR SHALL PROVIDE AN ANNUNICATOR PANEL AND INTERCONNECT DEVICES WITH LANDLORD'S CENTRAL FIRE ALARM SYSTEM. ALL DEVICES SHALL BE WHITE. 43 PROVIDE A RECESSED FLOOR DUPLEX RECEPTACLE. SEE DETAIL H ON SHEET E3.0 FOR MORE INFORMATION. e PROVIDE AN EDWARDS SYSTEMS MODEL# 6538 —G5, OR APPOVED EQUAL, CALL FOR ASSISTANCE KIT. KIT SHALL INCLUDE AN AUDIBLE HORN /STROBE, POWER TRANSFORMER, AND (2) PULL CORD STATIONS. PULL CORD STATIONS SHALL BE MOUNTED NEAR THE TOLIET, AS INDICATED. SEE DETAIL I, SHEET E3.0, FOR MORE INFORMATION. O. PROVIDE A CEILING MOUNTED JUNCTION BOX FOR AN OWNER FUNISHED SIGN AT THE CASHWRAP. COORDINATE EXACT LOCATION WITH ARCHTECTUAL SHEETS. I 2 GENERAL NOTES: APPROVED I Ft �t r rn -� RO � � VED P: � ..�,...� .. r,.�,.,A 10P! cuF1 t PICT "' C' ANGEED, MODIFIED OR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING 07FICIAL, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND ES 2:1J3. :::DT TO FIELD INSPECTIONS TYP 11 II if II 11 I II II II l l I 1 B-13>5 I I II I 11 1I II II 11 1 11 II I I II I I I I II 11 II 1 1 I !I 1 1 11 ..�-■ I I 1 I II I1 4 11P'-'! ~ II II ll I ll I fl l l I II I II 01 I 11 B' ll II 11 II II ll 1 1 II II 11 ll I 1 A ALL DEVICES SHALL BE NEW UNLESS OTHERWISE NOTED. COORDINATE LOCATION OF ALL OUTLETS AND SWITCHES WITH ARCHITECT'S DRAWINGS By i Date: City of Tul a 6UlL DING DP :1S ON B COORDINATE LOCATIONS OF SECURITY DEVICES WITH SECURITY CONTRACTOR. PROVIDE JUNCTION BOXES AND POWER AS REQUIRED. C ALL LINE, LOW VOLTAGE, DATA, COMMUNICATION. SECURITY, SOUND SYSTEM AND ANY OTHER WIRE PULLS SHALL BE IN CONDUIT UNLESS THE LOCAL CODES DO NOT REQUIRE IT. D RECEPTACLES NOTED AS ISOLATED GROUND (IG) SHALL BE ORANGE WITH A WHITE FACE PLATE. E REFER TO DETAIL B ON SHEET E4.0 FOR CONDUIT PENETRATIONS IN RATED WALLS. F ALL FIRE ALARM SYSTEM COMPONENTS PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR AND /OR LANDLORD CONTRACTOR. 1 I I Pu6Gc Works, Bulldog Division PERMIT NUMBER G ALL CONDUIT HOME RUNS TO THE ELECTRICAL PANELS SHALL BE EMT ONLY. FLEXIBLE ARMORED CABLE SHALL BE ALLOWED IN CONCEALED AREAS FOR BRANCH CIRCUITS WHERE IT IS ALLOWED BY THE NATIONAL FIRE COD AND THE LANDLORD. MALL COMMON REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC APR 2 5 NOB City Of Tukwila BUILDING DIVISION Piar review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted b or or. apt of approved Reid Copy and conditions is acknowledged: EVISION N E Lo7S93 FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. AREA: SCALE: DATE: FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 TSAO r APR 0 3 2CO PROJECT LOCATION: SHEET TITLE: PROJECT NO. DRAWN BY: REVIEWED BY: SHEET NO. RECEIVED APR 10 2008 PERMIT CENTER l■ FILL COPY Emphasis On ce M- Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 JOB #0712121 l de, to th^ Gt:nrh i No change ; shall he ma of work without prior approval of Tukwila Building Division NOTE: Revisions will require a new plan sl lhmittal and may include additional plan review tees 1. 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesign.com c SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 98118 ELECTRICAL POWER PJ>\ 5,439 SF 0712121 1 /4 " =1' - 0" 10 -08 -07 FJM DEG C B A A\ \ 04 -03-08 REVISION JAH WPK ,4\ 03 -27-08 REVISION JAH WPK JII 03 -19 -08 REVISION A\ \ 04 -03-08 REVISION JAH WPK ,4\ 03 -27-08 REVISION JAH WPK /3\ 03 -19 -08 REVISION RL MW /2\ 03 -14 -08 REVISION JAH WPK 02 -01 -08 ISSUE FOR BID JAH WPK 11 -12 -07 CITY COMMENTS RE- SUBMITTAL JAH WPK 10 -08 -07 ISSUE FOR PERMIT JAH WPK 07 -27 -07 CLIENT /PRELIM. LL REVIEW JAH WPK Q DATE ISSUE DESCRIPTION BY CHECK 5 5 4 4 3 3 2 2 1 1 112.5KVA TRANSFORMER BUILDING CORRIDOR FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. ELECTRICAL LIGHTING PLAN 1 /4 " =l' -0" ADJACENT TENANT ADJACENT TENANT O 0 0 V 0 0 V 0 10 11 CODED NOTES: PROVIDE J--BOX AND CONDUIT TO LIGHTING CONTROL PANEL FOR EMPLOYEE ON /OFF LOW VOLTAGE KEYPAD. CONTRACTOR MUST INSTALL MANUFACTURE SUPPLIED HINGED COVER PLATE. REFER TO "LV RELAY PANEL DIAGRAM ", SHEET E5.0, FOR MORE INFORMATION. PROVIDE A CAT5 CABLE TO THE LC &D CONTROL PANEL, AND MAKE ALL FINAL CONNECTIONS, FOR CONTROL OF THE RELAYS. MOUNT EXIT SIGN AT 11' -0" ABOVE THE FINISHED FLOOR OVER THE BLIND DOOR. CONNECT EXIT SIGN TO LOCAL LIGHTING CIRCUIT, AHEAD OF ANY SWITCHING. NON -SALES NIGHT /EMERGENCY LIGHT FIXTURE. THIS FIXTURE SHALL BE CONNECTED AHEAD OF ANY SWITCHING AND HAVE A BATTERY BACKUP TO PROVIDE AT LEAST 90 MIN. OF EMERGENCY ILLUMINATION AND MAINTAIN NOT LESS THAN 60% OF THE INITIAL EMERGENCY ILLUMINATION PER NEC 700.12 (F). PROVIDE 120V 20A SWITCH FOR CONTROL OF UNDER COUNTER LIGHT FIXTURE. FEED SWITCH FROM LOAD SIDE OF GFCI RECEPTACLE. REFER TO SHEET E1.0 FOR MORE INFORMATION. PROVIDE A THREE -LAMP DUAL BALLAST RECESSED FIXTURE. ONE BALLAST SHALL CONTROL THE CENTER LAMP WHICH WILL SERVE AS AN EMERGENCY LIGHT. THIS LAMP SHALL BE CONTROLLED BY THE WALL MOUNTED OCCUPANCY SENSOR UNDER NORMAL POWER, AND TURN ON, VIA A BATTERY BACK -UP WHEN NORMAL POWER IS LOSSED, REGARDLESS OF SWITCH POSITION. THE OTHER 2 LAMPS ARE TO BE WIRED TO THE 2 CIRCUIT WALL MOTION SENSOR SWITCH ALONG WITH EXHAUST FAN. a7 CONTRACTOR TO PROVIDE PULL BOX(ES) (SIZED PER NEC 314) FOR ALL LIGHTING CIRCUITS FEEDING THE SALES FLOOR, INCLUDING BUT NOT LIMITED TO TRACK AND COVE LIGHTING. MOUNT BOXES AS HIGH AS POSSIBLE ON BACK OF HOUSE WALL. ALL HOMERUNS FROM BACK TO PANEL ARE TO BE EMT. v PROVIDE J -BOX AND CONDUIT TO LIGHTING CONTROL PANEL FOR MASTER CONTROL ON /OFF LOW VOLTAGE KEYPAD. LOW VOLTAGE BUTTONS ARE TO BE IN 2 SEPARATE BOXES, ONE FOR EACH SWITCH. CONTRACTOR MUST INSTALL MANUFACTURE SUPPLIED HINGED COVER PLATE. SEE DETAIL #2 SHEET E -2. CONTRACTOR IS TO PROVIDE A CAT -5 CABLE BACK TO THE LC &D CONTROL PANEL, AND MAKE TERMINATION AT BOTH, FOR CONTROL OF THE RELAYS. CONNECT TRACK THUR CURRENT LIMITING PANEL. REFER TO "CURRENT LIMITING PANEL DIAGRAM ", SHEET E5.0, FOR MORE INFORMATION. PROVIDE J -BOX AND A 120V, 20A DEDICATED CIRCUIT FOR REAR SKIN CARE WALL LIGHTING. COORDINATE ALL RELATED WORK WITH SEPHORA CONTACT IN FIELD. CONNECT EXIT, EMERGENCY, NIGHT LIGHT FIXTURES IN SALES AREA TO CIRCUIT A -23. PROVIDE SCREW TYPE LO'S AT THE BREAKER. 12 COVE LIGHTS SHOWN ON PLAN ARE AN APPROXIMATION OF QUANTITY NEEDED. LIGHTING SUPPLIER SHALL PROVIDE SUFFICIENT FIXTURES TO CREATE A CONTINUOUS RUN. GENERAL NOTES: MALL COMMON A ALL DEVICES TO BE NEW UNLESS OTHERWISE NOTED. COORDINATE LOCATION OF ALL FIXTURES AND SWITCHES WITH ARCHITECT'S DRAWINGS. B THE LIGHTING FIXTURE SUPPLIER SHALL PROVIDE FROM THE FIXTURE MANUFACTURER A COMPLETE SET OF INSTRUCTIONS FOR OPERATION AND MAINTENANCE OF THE FIXTURES. AT EACH BATTERY UNIT A LOG OF THE ORIGINAL INSTALLATION DATE AND SUBSEQUENT MAINTENANCE DATES SHALL BE POSTED. C SEE SHEET E4.0 FOR LIGHT FIXTURE SCHEDULE. D ALL NORMAL LIGHTING CIRCUITS SHALL BE CONTROLLED THROUGH LOW VOLTAGE RELAY PANELS. INSTALL LV LJGHIING CONTROL SYSTEM. SEE SHEET E5.0 FOR MORE INFORMATION. E REFER TO DETAIL B ON SHEET E4.0 FOR CONDUIT PENETRATIONS IN RATED WALLS. F FOR EMERGENCY AND EXIT LIGHTING, FEED FIXTURE FROM ADJACENT LIGHTING CIRCUIT IN THE AREA AHEAD OF THE LIGHTING CONTROL PANEL. G ALL CONDUIT HOMERUNS TO THE ELECTRICAL PANELS SHALL BE EMT ONLY. FLEXIBLE ARMORED CABLE WILL ONLY BE ALLOWED IN CONCEALED AREAS FOR BRANCH CIRCUITS WHERE IT IS ALLOWED BY CODE AND THE LANDLORD. H REFER TO DETAIL A ON SHEET E4.0 FOR CEILING EQUIPMENT /FIXTURE MOUNTING. NOTE: 2006 IBC — Sec. 1006 Provide an average of one foot- candle illumination at the floor along the entire egress pathway and exit discharge ELOTh 583 PROJECT LOCATION: AREA: SHEET TITLE: ELECTRICAL LIGHTI PROJECT NO. 0712121 SCALE: 1/4"=l'-0" DATE: DRAWN BY: REVIEWED BY: FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 TSAO 41 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesign.com APR 0 3 2Q0$ On pence M- Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.8182337 SHEET NO. RECE1VEDE 2.0 APR 102008 PERMIT MITE JOB #0712121 N AL fr ; ergte EZ77s — 07 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 981 18 5,439 SF G PLAN FJM DEG 10 -08 -07 THE WIRE AND PUL • v .. STRINGS. •-____ '_ . / O \ 04 -03 -08 REVISION JAH WPK , AN. 03 -27 -08 REVISION JAH WPK /3\ 03 -19 -08 REVISION RL MW / \ 03 -14 -08 REVISION JAH WPK 02 -01 -08 ISSUE FOR BID JAH WPK / I \ 11 -12 -07 CITY COMMENTS RE- SUBMITTAL JAH WPK 10 -08 -07 ISSUE FOR PERMIT JAH WPK 07 -27 -07 CLIENT /PRELIM. LL REVIEW JAH WPK A DATE ISSUE DESCRIPTION BY CHECK 5 5 MANUFACTURER PROVIDED WHIP TO MAKE -UP MIRROR. (OPTIONAL) ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS. VERIFY EXACT NUMBER WITH ARCHITECTUAL SHEETS. (1) SPARE CAT. 5 GONDOLA DETAIL N.T.S. r. mrr=Mirri \tom 11 1 11" V / / ' / IG MMMUEkV/MMA � ' ! IMM T Ii i I • (4) CAT. 5 (1) DUPLEX ISOLATED GROUND RECEIPT. & (1) NORMAL POWER DUPLEX RECEPT. IN 4X4 BOX. TYPICAL CONDUIT STUB UP TYP. CONDUIT STUB UP TYPICAL (1) DUPLEX ISOLATED GROUND RECEIP' & (1) NORMAL POWER DUPLEX RECEP IN 4X4 BOX. TYPICAL (4) CAT. 5 (4) CAT. 5 -1 2 "C. W/ (4) CAT. 5 (1) 1- 1/2 "C. W/ (5) CAT. 5 (1) 1 "C. EMPTY SPARE WITH PULLSTRING: RUN BETWEEN CASH WRAP SIDES. (1) 3/4 "C. RUN BETWEEN CASH WRAP SIDES TO SUPPLY POWER TO THE GENERAL RECEPTACLES. (1) 1-1/2"C. W/ (5) CAT. 5 (1) 1-1/2"C. W/ (4) C 5 T II N.T.S. N.T.S. � - T (1)_1 "C. W/ (9) #12 rr (1) SPARE CAT. 5 SECTION a 44 9 (4) CAT. 5 (1) 3/4 "C. W/ PULL STRING FOR VOLUME CONTROL / / r / / / r 1) 3/4 "C. / / / WI PULL / / / I STRING / I FOR VOLUME / 4 CONTROL • FOUR SECTION CASH WRAP DETAIL 18" 48" RECEIVING DESK DETAIL T -FRAME MOUNTED J -BOX SUPPLED BY FIXTURE MANUFACTURER. ELECTRICAL CONTRACTOR TO MAKE UP BOXES AND TO PROVIDE CONDUIT AND WIRE TO MAKE FINAL CONNECTIONS BETWEEN THE 3 GONDOLA J- BOXES. ELECTRICAL CONTRACTOR IS TO PROVIDE A 6 FOOT, 2 #12 & 1 #12 GND SYPE SJO CORD AND PLUG A NEMA5 -20 FROM THE CENTER J -BOX TO THE DUPLEX OUTLET UNDER THE GONDOLA. FLUSH MOUNTED DUPLEX OUTLET FROM DETAIL H IS CENTERED UNDER THE THREE AND ONE SECTION GONDOLAS AND OFFSET UNDER 2 SECTION GONDOLAS. SAW CUT OPENING FOR FLEX CONDUIT CONNECTED TO EMT STUB -UP. CONDUIT SAW CUT OR CORE DRILLED (VERIFY WITH LANDLORD) IN FLOOR. BRING TO NEAREST WALL OR COLUMN AND UP TO CEIUNG. FLEX CONDUIT CONNECTED TO EMT STUB -UP. rrH CT E.M.T. CONDUIT NOTE: RIGID CONDUIT SHALL BE USED FOR FLOOR PENETRATIONS. NOTE: IF CASH WRAP FIXTURE COMES WITH WHffE DUPLEX RECEPTACLES IN THE ISOLATED GROUND LOCATION, REPLACE WITH ORANGE ISOLATED GROUND DEVICES. DOUBLE DUPLEX LOCATED ABOUT 48" A.F.F. (ONE DUPLEX TO BE IG AND ONE TO BE NORMAL) PROVIDE ONE RJ -11 AND ONE RJ -45 TO JUNCTION BOX IN THIS LOCATION FOR TEMP CONTROL TERMINATE HARD PIPE AT 108" A.F.F. TEMPERATURE CONTROL UNIT, PLUGED IN TO DOUBLE DUPLEX LOCATED ABOVE. PROVIDE (1) 2 NIPPLE BUSHING IN COVERPLATE ,r PROVIDE INSULATED BUSHINGS ON THE END OF CONDUITS AND A PULL CORD IN EACH 8"X8" RECESSED PULLBOX PROVIDE A 3 GAN MOUNTING OF PULL BOX AND RECEPTACLES CAN NOT EXCEED 24' FROM WALL (WIDTH OF SAFE AREA) 0 CONNECT TO NEAREST 120V, CONVENIENCE RECEPTACLE CIRCUIT. N 0 CONNECT TO NEAREST 120V, CONVENIENCE RECEPTACLE CIRCUIT. N 8' N.T.S. O 0 O 0 I — 2'4' I 2'8" TEL /DATA TERMINAL BOARD 24V SEC N.T.S. 6' r `I NETWORK DATA CABINET 24" WIDE X 84" HIGH X 32" DEEP KEEP THIS AREA CLEAR 24V, SYSTEM 1111 3.0 0 24V SEC 120V TO 24V SYSTEM TRANSFORMER IN NEMA 1 ENCLOSURE. EDWARDS #590 0 0 TERMINATE ALL DATA CONDUITS AT 108" A.F.F. WITHIN THE FIRST 24" OF THE DATA BOARD ON THIS SIDE DEDICATED (IG) DUPLEX FOR SCAN GUN LOCATED AT ABOUT 84" A.F.F. DEDICATED (IG) 30 AMP TWIST LOCK RECEPTACLE (NEMA L5 -30R) TO BE LOCATED ABOUT 18" A.F.F. N.T.S. �5\ COVERPLATE 42" PUSHBUTTON, SEE FLOOR PLAN FOR LOCATION. EDWARDS #1786C —B BUZZER IN SECURITY OFFICE, EDWARDS #C212W NON —SALES BUZZER, EDWARDS #C212W BUZZER NOTE: INSTALL A DELIVERY BUZZER SYSTEM AS SHOWN, INCLUDING EDWARDS #1786C —B PUSH BUTTON AT REAR DOOR, #590 TRANSFORMER, #C212W BUZZER IN OFFICE AND AT CASHWRAP AS INDICATED. COORDINATE ALL REQUIREMENTS WITH OWNER AS TO LOCATIONS AND QUANTITIES PRIOR TO BIDDING. DELIVERY BUZZER DETAIL N.T.S. PULL CORD STATION SEE FLOOR PLAN FOR LOCATION. EDWARDS #6537 AUIDIBLE ALARM STROBE, EDWARDS #6536 —G5 120V TO 24V SYSTEM TRANSFORMER IN NEMA 1 ENCLOSURE. EDWARDS #592 CEIUNG BOX WITH COVER PLATE FOR POWER. DE A SINGLE GANG BOX WITH COVER PLATE FOR DATA. CALL FOR ASSISTANCE DETAIL TELE /DATA GENERAL NOTES A) THIS DIAGRAM IS FOR REFERENCE PURPOSES AND MAY NOT NECESSARILY REFLECT THE EXACT ARRANGEMENT OF EQUIPMENT ON THE BACKBOARD. THIS IS THE "RECOMMENDED" PLAN, BUT STORE CONDITIONS MAY PREVENT THE BACKBOARD FROM BEING LAID OUT IN THIS SPECIFIC CONFIGURATION. HOWEVER, FOR EASE OF ACCESS AND PROXIMITY OF DEVICES, EVERY EFFORT SHOULD BE MADE TO INSTALL DEVICES AS CLOSELY TO THIS EXAMPLE AS POSSIBLE. DETAIL SHOWN FOR REFERENCE ONLY. FOR EXACT EQUIPMENT SIZES COORDINATE WITH TEL /DATA CONSULTANT B) ALL RECEPTACLES ARE TO BE MOUNTED 4" IN FROM THE CLOSEST EDGE OF THE PLYWOOD. C) E.C. IS TO PROVIDE A 6 AWG CONDUCTOR TO BOND THE COMMUNICATION GROUNDING ELECTRODE AND THE POWER GROUNDING ELECTRODE SYSTEM. COUNTER TOP 44 FLOOR SECURITY COUNTER DETAIL CALL FOR ASSISTANCE NOTE: INSTALL AN EDWARDS MODEL#6538 —G5 CALL FOR ASSISTANCE SYSTEM AS SHOWN, INCLUDING EDWARDS #6537 PULL CORDS AT NEAR THE TOLIETS, #592 TRANSFORMER, #6536 —G5 HORN /STROBE OUTSIDE THE RESTROOMS WHERE INDICATED. VERIFY MOUNTING HEIGHTS AND REQUIREMENTS PRIOR TO BIDDING. - 54" SAW CUT /CHIP OUT EXISTING CONCRETE SLAB AND PROVIDE WATER PROOF GROUT SEAL WALL DISPLAY #1 • CONDUIT FOR POWER WALL DISPLAY #2 SECTION PLAN DISPLAY # 0 WALL DISPLAY # NOTES: WALL DISPLAY # THREE DISPLAYS ARE WIRED TO A JUNCTION BOX LOCATED 54 FROM THE LEFT END. THIS CENTERS THE BOX ON THE 2ND SECTION OF PLUGMOLD. WALL FIXTURE POWER CONNECTION DETAIL N.T.S. OWNER PROVIDED THOMAS & BETTS - STEEEL CITY MODEL 640 OR 840SC FLOOR OUTLET CAST IRON CONCRETE TIGHT FLOOR BOX WITH THOMAS & BETTS -STEEL CITY MODEL F64-- D5--AL COVERPLATE TO BE THOMAS & BETTS- STEEL CITY MODEL # P64 -LCP ALUMINUM CARPET PLATE WITH (2) FUP UDS AND (1) 20 AMP 120 VOLT DUPLEX RECEPTACLE. FILL BACK IN W/ CONCRETE AS NEEDED ONLY REMOVE /CHIP OUT ENOUGH CONCRETE TO CONCEAL CONDUIT. VERIFY CONCRETE SLAB DEPTH AND ADD CONCRETE WHERE NEEDED TO HAVE 3" MINIMUM CONCRETE UNDER FLUSH FLOOR BOX \\— LEVEUNG SCREWS AT EACH CORNER CONDUIT FOR POWER 3/4 "C. MAX. SIZE SLAB GRADE SLAB -ON -GRADE FLUSH FLOOR BOX DETAIL N.T.S. ELECTRICAL J -BOX AND WALL MOUNTED WRING SUPPLIED BY ELECTRICAL CONTRACTOR. MOUNT AT 48" AFF. CENTER ON FIXTURE INDICATED. PLUGMOLD PROVIDED BY FIXTURE MANUFACTURER. CONDUIT /WIRES SUPPLIED BY FIXTURE MANUFACTURER, 96" LONG PLAN VIEW TOP VIEW COVER PLATE 583 4 4 3 3 2 2 1 1 AREA: SHEET TITLE: DATE: DRAWN BY: REVIEWED BY: SHEET NO. FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 TSAO P'R0 PROJECT LOCATION: 0 IA 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesig com Embeds Qn Excellence M Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 JOB 0712121 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 98118 ELECTRICAL DETAILS RECEIVED E 3 . 0 AIM 1 0 2008 PERMIT CENTER 5,439 SF PROJECT NO. 0712121 SCALE: NONE 10 -08 -07 FJM DEG `---- AND OR CONCRETE v ° • • • ` `•' V • P a °• A / O \ 04 -03 -08 REVISION JAH WPK , AN. 03 -27 -08 REVISION JAH WPK /3\ 03 -19 -08 REVISION RL MW / \ 03 -14 -08 REVISION JAH WPK 02 -01 -08 ISSUE FOR BID JAH WPK / I \ 11 -12 -07 CITY COMMENTS RE- SUBMITTAL JAH WPK 10 -08 -07 ISSUE FOR PERMIT JAH WPK 07 -27 -07 CLIENT /PRELIM. LL REVIEW JAH WPK A DATE ISSUE DESCRIPTION BY CHECK 5 5 MANUFACTURER PROVIDED WHIP TO MAKE -UP MIRROR. (OPTIONAL) ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS. VERIFY EXACT NUMBER WITH ARCHITECTUAL SHEETS. (1) SPARE CAT. 5 GONDOLA DETAIL N.T.S. r. mrr=Mirri \tom 11 1 11" V / / ' / IG MMMUEkV/MMA � ' ! IMM T Ii i I • (4) CAT. 5 (1) DUPLEX ISOLATED GROUND RECEIPT. & (1) NORMAL POWER DUPLEX RECEPT. IN 4X4 BOX. TYPICAL CONDUIT STUB UP TYP. CONDUIT STUB UP TYPICAL (1) DUPLEX ISOLATED GROUND RECEIP' & (1) NORMAL POWER DUPLEX RECEP IN 4X4 BOX. TYPICAL (4) CAT. 5 (4) CAT. 5 -1 2 "C. W/ (4) CAT. 5 (1) 1- 1/2 "C. W/ (5) CAT. 5 (1) 1 "C. EMPTY SPARE WITH PULLSTRING: RUN BETWEEN CASH WRAP SIDES. (1) 3/4 "C. RUN BETWEEN CASH WRAP SIDES TO SUPPLY POWER TO THE GENERAL RECEPTACLES. (1) 1-1/2"C. W/ (5) CAT. 5 (1) 1-1/2"C. W/ (4) C 5 T II N.T.S. N.T.S. � - T (1)_1 "C. W/ (9) #12 rr (1) SPARE CAT. 5 SECTION a 44 9 (4) CAT. 5 (1) 3/4 "C. W/ PULL STRING FOR VOLUME CONTROL / / r / / / r 1) 3/4 "C. / / / WI PULL / / / I STRING / I FOR VOLUME / 4 CONTROL • FOUR SECTION CASH WRAP DETAIL 18" 48" RECEIVING DESK DETAIL T -FRAME MOUNTED J -BOX SUPPLED BY FIXTURE MANUFACTURER. ELECTRICAL CONTRACTOR TO MAKE UP BOXES AND TO PROVIDE CONDUIT AND WIRE TO MAKE FINAL CONNECTIONS BETWEEN THE 3 GONDOLA J- BOXES. ELECTRICAL CONTRACTOR IS TO PROVIDE A 6 FOOT, 2 #12 & 1 #12 GND SYPE SJO CORD AND PLUG A NEMA5 -20 FROM THE CENTER J -BOX TO THE DUPLEX OUTLET UNDER THE GONDOLA. FLUSH MOUNTED DUPLEX OUTLET FROM DETAIL H IS CENTERED UNDER THE THREE AND ONE SECTION GONDOLAS AND OFFSET UNDER 2 SECTION GONDOLAS. SAW CUT OPENING FOR FLEX CONDUIT CONNECTED TO EMT STUB -UP. CONDUIT SAW CUT OR CORE DRILLED (VERIFY WITH LANDLORD) IN FLOOR. BRING TO NEAREST WALL OR COLUMN AND UP TO CEIUNG. FLEX CONDUIT CONNECTED TO EMT STUB -UP. rrH CT E.M.T. CONDUIT NOTE: RIGID CONDUIT SHALL BE USED FOR FLOOR PENETRATIONS. NOTE: IF CASH WRAP FIXTURE COMES WITH WHffE DUPLEX RECEPTACLES IN THE ISOLATED GROUND LOCATION, REPLACE WITH ORANGE ISOLATED GROUND DEVICES. DOUBLE DUPLEX LOCATED ABOUT 48" A.F.F. (ONE DUPLEX TO BE IG AND ONE TO BE NORMAL) PROVIDE ONE RJ -11 AND ONE RJ -45 TO JUNCTION BOX IN THIS LOCATION FOR TEMP CONTROL TERMINATE HARD PIPE AT 108" A.F.F. TEMPERATURE CONTROL UNIT, PLUGED IN TO DOUBLE DUPLEX LOCATED ABOVE. PROVIDE (1) 2 NIPPLE BUSHING IN COVERPLATE ,r PROVIDE INSULATED BUSHINGS ON THE END OF CONDUITS AND A PULL CORD IN EACH 8"X8" RECESSED PULLBOX PROVIDE A 3 GAN MOUNTING OF PULL BOX AND RECEPTACLES CAN NOT EXCEED 24' FROM WALL (WIDTH OF SAFE AREA) 0 CONNECT TO NEAREST 120V, CONVENIENCE RECEPTACLE CIRCUIT. N 0 CONNECT TO NEAREST 120V, CONVENIENCE RECEPTACLE CIRCUIT. N 8' N.T.S. O 0 O 0 I — 2'4' I 2'8" TEL /DATA TERMINAL BOARD 24V SEC N.T.S. 6' r `I NETWORK DATA CABINET 24" WIDE X 84" HIGH X 32" DEEP KEEP THIS AREA CLEAR 24V, SYSTEM 1111 3.0 0 24V SEC 120V TO 24V SYSTEM TRANSFORMER IN NEMA 1 ENCLOSURE. EDWARDS #590 0 0 TERMINATE ALL DATA CONDUITS AT 108" A.F.F. WITHIN THE FIRST 24" OF THE DATA BOARD ON THIS SIDE DEDICATED (IG) DUPLEX FOR SCAN GUN LOCATED AT ABOUT 84" A.F.F. DEDICATED (IG) 30 AMP TWIST LOCK RECEPTACLE (NEMA L5 -30R) TO BE LOCATED ABOUT 18" A.F.F. N.T.S. �5\ COVERPLATE 42" PUSHBUTTON, SEE FLOOR PLAN FOR LOCATION. EDWARDS #1786C —B BUZZER IN SECURITY OFFICE, EDWARDS #C212W NON —SALES BUZZER, EDWARDS #C212W BUZZER NOTE: INSTALL A DELIVERY BUZZER SYSTEM AS SHOWN, INCLUDING EDWARDS #1786C —B PUSH BUTTON AT REAR DOOR, #590 TRANSFORMER, #C212W BUZZER IN OFFICE AND AT CASHWRAP AS INDICATED. COORDINATE ALL REQUIREMENTS WITH OWNER AS TO LOCATIONS AND QUANTITIES PRIOR TO BIDDING. DELIVERY BUZZER DETAIL N.T.S. PULL CORD STATION SEE FLOOR PLAN FOR LOCATION. EDWARDS #6537 AUIDIBLE ALARM STROBE, EDWARDS #6536 —G5 120V TO 24V SYSTEM TRANSFORMER IN NEMA 1 ENCLOSURE. EDWARDS #592 CEIUNG BOX WITH COVER PLATE FOR POWER. DE A SINGLE GANG BOX WITH COVER PLATE FOR DATA. CALL FOR ASSISTANCE DETAIL TELE /DATA GENERAL NOTES A) THIS DIAGRAM IS FOR REFERENCE PURPOSES AND MAY NOT NECESSARILY REFLECT THE EXACT ARRANGEMENT OF EQUIPMENT ON THE BACKBOARD. THIS IS THE "RECOMMENDED" PLAN, BUT STORE CONDITIONS MAY PREVENT THE BACKBOARD FROM BEING LAID OUT IN THIS SPECIFIC CONFIGURATION. HOWEVER, FOR EASE OF ACCESS AND PROXIMITY OF DEVICES, EVERY EFFORT SHOULD BE MADE TO INSTALL DEVICES AS CLOSELY TO THIS EXAMPLE AS POSSIBLE. DETAIL SHOWN FOR REFERENCE ONLY. FOR EXACT EQUIPMENT SIZES COORDINATE WITH TEL /DATA CONSULTANT B) ALL RECEPTACLES ARE TO BE MOUNTED 4" IN FROM THE CLOSEST EDGE OF THE PLYWOOD. C) E.C. IS TO PROVIDE A 6 AWG CONDUCTOR TO BOND THE COMMUNICATION GROUNDING ELECTRODE AND THE POWER GROUNDING ELECTRODE SYSTEM. COUNTER TOP 44 FLOOR SECURITY COUNTER DETAIL CALL FOR ASSISTANCE NOTE: INSTALL AN EDWARDS MODEL#6538 —G5 CALL FOR ASSISTANCE SYSTEM AS SHOWN, INCLUDING EDWARDS #6537 PULL CORDS AT NEAR THE TOLIETS, #592 TRANSFORMER, #6536 —G5 HORN /STROBE OUTSIDE THE RESTROOMS WHERE INDICATED. VERIFY MOUNTING HEIGHTS AND REQUIREMENTS PRIOR TO BIDDING. - 54" SAW CUT /CHIP OUT EXISTING CONCRETE SLAB AND PROVIDE WATER PROOF GROUT SEAL WALL DISPLAY #1 • CONDUIT FOR POWER WALL DISPLAY #2 SECTION PLAN DISPLAY # 0 WALL DISPLAY # NOTES: WALL DISPLAY # THREE DISPLAYS ARE WIRED TO A JUNCTION BOX LOCATED 54 FROM THE LEFT END. THIS CENTERS THE BOX ON THE 2ND SECTION OF PLUGMOLD. WALL FIXTURE POWER CONNECTION DETAIL N.T.S. OWNER PROVIDED THOMAS & BETTS - STEEEL CITY MODEL 640 OR 840SC FLOOR OUTLET CAST IRON CONCRETE TIGHT FLOOR BOX WITH THOMAS & BETTS -STEEL CITY MODEL F64-- D5--AL COVERPLATE TO BE THOMAS & BETTS- STEEL CITY MODEL # P64 -LCP ALUMINUM CARPET PLATE WITH (2) FUP UDS AND (1) 20 AMP 120 VOLT DUPLEX RECEPTACLE. FILL BACK IN W/ CONCRETE AS NEEDED ONLY REMOVE /CHIP OUT ENOUGH CONCRETE TO CONCEAL CONDUIT. VERIFY CONCRETE SLAB DEPTH AND ADD CONCRETE WHERE NEEDED TO HAVE 3" MINIMUM CONCRETE UNDER FLUSH FLOOR BOX \\— LEVEUNG SCREWS AT EACH CORNER CONDUIT FOR POWER 3/4 "C. MAX. SIZE SLAB GRADE SLAB -ON -GRADE FLUSH FLOOR BOX DETAIL N.T.S. ELECTRICAL J -BOX AND WALL MOUNTED WRING SUPPLIED BY ELECTRICAL CONTRACTOR. MOUNT AT 48" AFF. CENTER ON FIXTURE INDICATED. PLUGMOLD PROVIDED BY FIXTURE MANUFACTURER. CONDUIT /WIRES SUPPLIED BY FIXTURE MANUFACTURER, 96" LONG PLAN VIEW TOP VIEW COVER PLATE 583 4 4 3 3 2 2 1 1 AREA: SHEET TITLE: DATE: DRAWN BY: REVIEWED BY: SHEET NO. FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 TSAO P'R0 PROJECT LOCATION: 0 IA 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesig com Embeds Qn Excellence M Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 JOB 0712121 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 98118 ELECTRICAL DETAILS RECEIVED E 3 . 0 AIM 1 0 2008 PERMIT CENTER 5,439 SF PROJECT NO. 0712121 SCALE: NONE 10 -08 -07 FJM DEG 5 5 MANUFACTURER PROVIDED WHIP TO MAKE -UP MIRROR. (OPTIONAL) ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS. VERIFY EXACT NUMBER WITH ARCHITECTUAL SHEETS. (1) SPARE CAT. 5 GONDOLA DETAIL N.T.S. r. mrr=Mirri \tom 11 1 11" V / / ' / IG MMMUEkV/MMA � ' ! IMM T Ii i I • (4) CAT. 5 (1) DUPLEX ISOLATED GROUND RECEIPT. & (1) NORMAL POWER DUPLEX RECEPT. IN 4X4 BOX. TYPICAL CONDUIT STUB UP TYP. CONDUIT STUB UP TYPICAL (1) DUPLEX ISOLATED GROUND RECEIP' & (1) NORMAL POWER DUPLEX RECEP IN 4X4 BOX. TYPICAL (4) CAT. 5 (4) CAT. 5 -1 2 "C. W/ (4) CAT. 5 (1) 1- 1/2 "C. W/ (5) CAT. 5 (1) 1 "C. EMPTY SPARE WITH PULLSTRING: RUN BETWEEN CASH WRAP SIDES. (1) 3/4 "C. RUN BETWEEN CASH WRAP SIDES TO SUPPLY POWER TO THE GENERAL RECEPTACLES. (1) 1-1/2"C. W/ (5) CAT. 5 (1) 1-1/2"C. W/ (4) C 5 T II N.T.S. N.T.S. � - T (1)_1 "C. W/ (9) #12 rr (1) SPARE CAT. 5 SECTION a 44 9 (4) CAT. 5 (1) 3/4 "C. W/ PULL STRING FOR VOLUME CONTROL / / r / / / r 1) 3/4 "C. / / / WI PULL / / / I STRING / I FOR VOLUME / 4 CONTROL • FOUR SECTION CASH WRAP DETAIL 18" 48" RECEIVING DESK DETAIL T -FRAME MOUNTED J -BOX SUPPLED BY FIXTURE MANUFACTURER. ELECTRICAL CONTRACTOR TO MAKE UP BOXES AND TO PROVIDE CONDUIT AND WIRE TO MAKE FINAL CONNECTIONS BETWEEN THE 3 GONDOLA J- BOXES. ELECTRICAL CONTRACTOR IS TO PROVIDE A 6 FOOT, 2 #12 & 1 #12 GND SYPE SJO CORD AND PLUG A NEMA5 -20 FROM THE CENTER J -BOX TO THE DUPLEX OUTLET UNDER THE GONDOLA. FLUSH MOUNTED DUPLEX OUTLET FROM DETAIL H IS CENTERED UNDER THE THREE AND ONE SECTION GONDOLAS AND OFFSET UNDER 2 SECTION GONDOLAS. SAW CUT OPENING FOR FLEX CONDUIT CONNECTED TO EMT STUB -UP. CONDUIT SAW CUT OR CORE DRILLED (VERIFY WITH LANDLORD) IN FLOOR. BRING TO NEAREST WALL OR COLUMN AND UP TO CEIUNG. FLEX CONDUIT CONNECTED TO EMT STUB -UP. rrH CT E.M.T. CONDUIT NOTE: RIGID CONDUIT SHALL BE USED FOR FLOOR PENETRATIONS. NOTE: IF CASH WRAP FIXTURE COMES WITH WHffE DUPLEX RECEPTACLES IN THE ISOLATED GROUND LOCATION, REPLACE WITH ORANGE ISOLATED GROUND DEVICES. DOUBLE DUPLEX LOCATED ABOUT 48" A.F.F. (ONE DUPLEX TO BE IG AND ONE TO BE NORMAL) PROVIDE ONE RJ -11 AND ONE RJ -45 TO JUNCTION BOX IN THIS LOCATION FOR TEMP CONTROL TERMINATE HARD PIPE AT 108" A.F.F. TEMPERATURE CONTROL UNIT, PLUGED IN TO DOUBLE DUPLEX LOCATED ABOVE. PROVIDE (1) 2 NIPPLE BUSHING IN COVERPLATE ,r PROVIDE INSULATED BUSHINGS ON THE END OF CONDUITS AND A PULL CORD IN EACH 8"X8" RECESSED PULLBOX PROVIDE A 3 GAN MOUNTING OF PULL BOX AND RECEPTACLES CAN NOT EXCEED 24' FROM WALL (WIDTH OF SAFE AREA) 0 CONNECT TO NEAREST 120V, CONVENIENCE RECEPTACLE CIRCUIT. N 0 CONNECT TO NEAREST 120V, CONVENIENCE RECEPTACLE CIRCUIT. N 8' N.T.S. O 0 O 0 I — 2'4' I 2'8" TEL /DATA TERMINAL BOARD 24V SEC N.T.S. 6' r `I NETWORK DATA CABINET 24" WIDE X 84" HIGH X 32" DEEP KEEP THIS AREA CLEAR 24V, SYSTEM 1111 3.0 0 24V SEC 120V TO 24V SYSTEM TRANSFORMER IN NEMA 1 ENCLOSURE. EDWARDS #590 0 0 TERMINATE ALL DATA CONDUITS AT 108" A.F.F. WITHIN THE FIRST 24" OF THE DATA BOARD ON THIS SIDE DEDICATED (IG) DUPLEX FOR SCAN GUN LOCATED AT ABOUT 84" A.F.F. DEDICATED (IG) 30 AMP TWIST LOCK RECEPTACLE (NEMA L5 -30R) TO BE LOCATED ABOUT 18" A.F.F. N.T.S. �5\ COVERPLATE 42" PUSHBUTTON, SEE FLOOR PLAN FOR LOCATION. EDWARDS #1786C —B BUZZER IN SECURITY OFFICE, EDWARDS #C212W NON —SALES BUZZER, EDWARDS #C212W BUZZER NOTE: INSTALL A DELIVERY BUZZER SYSTEM AS SHOWN, INCLUDING EDWARDS #1786C —B PUSH BUTTON AT REAR DOOR, #590 TRANSFORMER, #C212W BUZZER IN OFFICE AND AT CASHWRAP AS INDICATED. COORDINATE ALL REQUIREMENTS WITH OWNER AS TO LOCATIONS AND QUANTITIES PRIOR TO BIDDING. DELIVERY BUZZER DETAIL N.T.S. PULL CORD STATION SEE FLOOR PLAN FOR LOCATION. EDWARDS #6537 AUIDIBLE ALARM STROBE, EDWARDS #6536 —G5 120V TO 24V SYSTEM TRANSFORMER IN NEMA 1 ENCLOSURE. EDWARDS #592 CEIUNG BOX WITH COVER PLATE FOR POWER. DE A SINGLE GANG BOX WITH COVER PLATE FOR DATA. CALL FOR ASSISTANCE DETAIL TELE /DATA GENERAL NOTES A) THIS DIAGRAM IS FOR REFERENCE PURPOSES AND MAY NOT NECESSARILY REFLECT THE EXACT ARRANGEMENT OF EQUIPMENT ON THE BACKBOARD. THIS IS THE "RECOMMENDED" PLAN, BUT STORE CONDITIONS MAY PREVENT THE BACKBOARD FROM BEING LAID OUT IN THIS SPECIFIC CONFIGURATION. HOWEVER, FOR EASE OF ACCESS AND PROXIMITY OF DEVICES, EVERY EFFORT SHOULD BE MADE TO INSTALL DEVICES AS CLOSELY TO THIS EXAMPLE AS POSSIBLE. DETAIL SHOWN FOR REFERENCE ONLY. FOR EXACT EQUIPMENT SIZES COORDINATE WITH TEL /DATA CONSULTANT B) ALL RECEPTACLES ARE TO BE MOUNTED 4" IN FROM THE CLOSEST EDGE OF THE PLYWOOD. C) E.C. IS TO PROVIDE A 6 AWG CONDUCTOR TO BOND THE COMMUNICATION GROUNDING ELECTRODE AND THE POWER GROUNDING ELECTRODE SYSTEM. COUNTER TOP 44 FLOOR SECURITY COUNTER DETAIL CALL FOR ASSISTANCE NOTE: INSTALL AN EDWARDS MODEL#6538 —G5 CALL FOR ASSISTANCE SYSTEM AS SHOWN, INCLUDING EDWARDS #6537 PULL CORDS AT NEAR THE TOLIETS, #592 TRANSFORMER, #6536 —G5 HORN /STROBE OUTSIDE THE RESTROOMS WHERE INDICATED. VERIFY MOUNTING HEIGHTS AND REQUIREMENTS PRIOR TO BIDDING. - 54" SAW CUT /CHIP OUT EXISTING CONCRETE SLAB AND PROVIDE WATER PROOF GROUT SEAL WALL DISPLAY #1 • CONDUIT FOR POWER WALL DISPLAY #2 SECTION PLAN DISPLAY # 0 WALL DISPLAY # NOTES: WALL DISPLAY # THREE DISPLAYS ARE WIRED TO A JUNCTION BOX LOCATED 54 FROM THE LEFT END. THIS CENTERS THE BOX ON THE 2ND SECTION OF PLUGMOLD. WALL FIXTURE POWER CONNECTION DETAIL N.T.S. OWNER PROVIDED THOMAS & BETTS - STEEEL CITY MODEL 640 OR 840SC FLOOR OUTLET CAST IRON CONCRETE TIGHT FLOOR BOX WITH THOMAS & BETTS -STEEL CITY MODEL F64-- D5--AL COVERPLATE TO BE THOMAS & BETTS- STEEL CITY MODEL # P64 -LCP ALUMINUM CARPET PLATE WITH (2) FUP UDS AND (1) 20 AMP 120 VOLT DUPLEX RECEPTACLE. FILL BACK IN W/ CONCRETE AS NEEDED ONLY REMOVE /CHIP OUT ENOUGH CONCRETE TO CONCEAL CONDUIT. VERIFY CONCRETE SLAB DEPTH AND ADD CONCRETE WHERE NEEDED TO HAVE 3" MINIMUM CONCRETE UNDER FLUSH FLOOR BOX \\— LEVEUNG SCREWS AT EACH CORNER CONDUIT FOR POWER 3/4 "C. MAX. SIZE SLAB GRADE SLAB -ON -GRADE FLUSH FLOOR BOX DETAIL N.T.S. ELECTRICAL J -BOX AND WALL MOUNTED WRING SUPPLIED BY ELECTRICAL CONTRACTOR. MOUNT AT 48" AFF. CENTER ON FIXTURE INDICATED. PLUGMOLD PROVIDED BY FIXTURE MANUFACTURER. CONDUIT /WIRES SUPPLIED BY FIXTURE MANUFACTURER, 96" LONG PLAN VIEW TOP VIEW COVER PLATE 583 4 4 3 3 2 2 1 1 AREA: SHEET TITLE: DATE: DRAWN BY: REVIEWED BY: SHEET NO. FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 TSAO P'R0 PROJECT LOCATION: 0 IA 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesig com Embeds Qn Excellence M Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 JOB 0712121 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 98118 ELECTRICAL DETAILS RECEIVED E 3 . 0 AIM 1 0 2008 PERMIT CENTER 5,439 SF PROJECT NO. 0712121 SCALE: NONE 10 -08 -07 FJM DEG LIGHTING FIXTURE SCHEDULE SYMBOL DESCRIPTION DESCRIPTION MANUFACTURER & MODEL NUMBER NOTE LAMP WATTAGE VOLTAGE FA - 1 AURESCENT LENSED TROFFLER. 2'- 0"X4' -0" RECESSED FLOURESCENT TRACK MOUNTED METAL HALIDE ACCENT LIGHT. LIGHTOUER, SOF —TECH. 8338 WH (3) F32T8. 32 WATT 25 WATT. PAR38. CERAMIC 25 WATTS 120 V METAL HALIDE LAMP. 30' NARROW FLOOD. 10.000 LAMP, 2000 HOURS. 5900 LUMENS. 3000' HOURS. 2200 LUMENS. 3000' KELVIN. 81 CR1 BY PHILIPS KELVIN 82 CRI BY PHIUPS FA -1(T) JAH SINGLE CIRCUIT TRACK AVAILABLE IN THE FOLLOWING LENGTHS: UGHTOUER, BASIC LYTESPAN SINGLE CIRCUIT TRACK. VERIFY WHETHER PENDANT OR SURFACE MOUNTED N/A N/A 120 V , 4. ISSUE FOR PERMIT SERIES 6000 WPK E 12: FJ UGHTALARMS — SPLEDDWRCD FIXTURE'S PROVIDED WITH BAULKY PACK TO PROVIDE 90 MINUTES OF EMERGENCY OPERATION STAGGERER ( ADJISTABLE) 35 FLUORESCENT STRIP BARTCO. BFL281 (SINGLE LAMP) 120 V 1 —(:28 T5. 32 WATT FLUORESCENT 32 WATTS 120 V DAMP. 2000 HOURS. 5900 LUMENS. 1--- -0 I UGHTOUER — SOLUTIONWCL (2) 35W. MR16 LAMPS 3000' KELVIN 82 CRI BY PHIUPS 120 V FJ - 1 Q Q ( STAGGERED T5 FLUORESCENT STRIP BARTCO. BFL281 - •2 (ADJUSTABLE TWP LAMP) BALLAST INTEGRAL WITH UNIT 2 —F28 T5. 32 WATT 64 WATTS 120 V FLUORESCENT LAMP, 2000 .01 C6P38D 120 WATT, PAR38, CERAMIC HOURS, 5900 LUMENS. X000' KELVIN 82 CRI BY PHILIPS METAL HALIDE LAME. 2000 NARROW FLOOD, 2000 WOURS, FU3 2200 LUMENS. 3000' KELVIN. 1' X 4" RECESSED FLUORESCENT LENSED TROFFER. MERCURY 31 E 2 32 OCT-- 9A ELB• - UNI SEE NOTE "B" BELOW AND AND WITH LIGHTING PLAN (2) F32T8. 32 WATT 58 WATTS 120 V FLUORESCENT LAMP, 2000 { r HOURS, 5900 LUMENS, 3000' HOURS. /NL -EM 82 CRI BY PHILIPS ' • :: .. • am ; 4:;,. a ; a 1l : JAI. a,t:7a•�: L.::1= --= �. SEE NOTE :E LOW 12) F32T8, 32 WATT UOR SCENT • MP 000 HOURS. 5900 LUMENS. 3000' KELVIN 82 CRI BY PHILIPS - -. ru 1 �. __ _ .. ... WITH - _ PLAN IAAPFRIA TA WALL WAgu -- �.: BrALT z n _TA — G ua — r_A � n unu WLC•np T'EF? MAUBC Li) 3W £ M 44 WAIT 120 V • LIGHTING FIXTURE SCHEDULE SYMBOL DESCRIPTION MANUFACTURER & MODEL NUMBER NOTE LAMP WATTAGE VOLTAGE FT JAH AURESCENT LENSED TROFFLER. 2'- 0"X4' -0" RECESSED FLOURESCENT MERCURY 35E 332 OCT 9A — ELB - 120 SEE NOTE " B " BELOW AND COORDINATE WITH LIGHTING PLAN (3) F32T8. 32 WATT 86 WATTS 120 V MW 0 03 -14 -08 LAMP, 2000 HOURS. 5900 LUMENS. 3000' WPK KELVIN 82 CRI BY PHIUPS ISSUE FOR BID JAH G3 I-10—I UNDER CABINET FIXTURE ALKO QUICK INCH 0116— RSW —L —ELB JAH (?} F6r5 21 WATTS 120 V ISSUE FOR PERMIT JAM WPK E 2 SINGAL FACE 2 DOUBLE FACE 2 W /DIRECI1ONAL ARROWS WAI I MOUNTED. I FD I IT. EXIT SIGN, UGHTALARMS — SPLEDDWRCD FIXTURE'S PROVIDED WITH BAULKY PACK TO PROVIDE 90 MINUTES OF EMERGENCY OPERATION LED LAMPS INCLUDED WITH FIXTURE 3.5 WATTS 120 V BY CHECK X6 RECESSED EMERGENCY LIGHT FIXTURE WfTH BATTERY PACK UGHTOUER — SOLUTIONWCL (2) 35W. MR16 LAMPS 72 WATTS 120 V Q Q ( Si 0 6" INCANDESCENT DOWNUGHT .01 C6P38D 120 WATT, PAR38, CERAMIC 120 WATTS 120 V METAL HALIDE LAME. 2000 NARROW FLOOD, 2000 WOURS, 2200 LUMENS. 3000' KELVIN. 81 CR1 BY PHIUPS NOTES: { r /NL -EM /NL /NL -EM /EM JJIGHT LIGHT NIGHT UGHT /EQUIPPED WITH BATTERY BACKUP EMERGENCY LIGHT EQUIPPED WITH BATTERY BACKUP EMERGENCY LIGHT' L 04 -03 -08 REVISION JAH WPK / \ 03x27 -08 REVISION JAH WPK i L 03 -19-08 REVISION RL MW /2\ 03 -14 -08 REVISION JAH WPK 02 -01 -08 ISSUE FOR BID JAH WPK A 11 -12 -07 CITY COMMENTS RE- SUBMITTAL JAH WPK 10-08 -07 ISSUE FOR PERMIT JAM WPK 07 -27 -07 CLIENT /PRELIM. LL REVIEW JAH WPK A DATE ISSUE DESCRIPTION BY CHECK 5 5 4 4 3 3 2 FOR FIXTURES WEIGHING LESS THAN 56 POUNDS O MINIMUM TWO #12 GAUGE SLACK WIRE AT 45 DEGREES FROM OPPOSITE FIXTURE CORNERS TO STRUCTURE ABOVE. ATTACH DIRECTLY TO FIXTURE WITH 3 TURN TIGHT WRAP MINIMUM. ATTACH TO STRUCTURE PER ACOUSTICAL CEILING ATTACHMENT DETAILS. SET WIRE SLIGHTLY SLACK, TO ALLOW FULL SEATING INTO T —BAR. © POSITIVELY ATTACH FIXTURE WITH METAL SCREW THROUGH T —BAR INTO FIXTURE AT OPPOSITE CORNERS. FOR FIXTURES WEIGHING 56 POUNDS OR MQRL O 12 GAUGE SUPPORT WIRES WITH THREE TURN TIGHT WRAP (WITHIN 1 1/2 ") MINIMUM AT EACH END. ATTACH TO STRUCTURE DIRECTLY ABOVE PER CEILING SUSPENSION DETAILS (4 PER FIXTURE). PENDANT HUNG FIXTURES Q 9 GAUGE SUPPORT WIRES WITH THREE TURN TIGHT WRAP (WITHIN 1 1/2 ") MINIMUM AT EACH END. ATTACH TO STRUCTURE DIRECTLY ABOVE PER CEILING SUSPENSION DETAILS. T—BAR CE UN CEILING MEMBERS N.T.S. T —BAR CEILING MEMBERS FIXTURE MOUNTING DETAIL NOT TO SCALE MAIN RUNNER EQUIPMENT /FIXTURE MOUNTING NOT TO SCALE MAIN RUNNER TYPICAL RECESSED TROFFER IN HEAVY DUTY T —BAR CEILING TYPICAL RECESSED FIXTURE MINIMUM 12 GAUGE SLACK WIRE AT 45 DEGREES FROM OPPOSITE EQUIP. HOUSING CORNERS TO STRUCTURE ABOVE. ATTACH DIRECTLY TO FIXTURE WITH 3 TURN TIGHT WRAP MINIMUM. ATTACH TO STRUCTURE PER ACOUSTICAL CEILING ATTACHMENT DETAILS. SET WIRE SLIGHTLY SLACK, TO ALLOW FULL SEATING INTO T —BAR. CROSS RUNNER TYPICAL CEILING MID. EQUIPMENT SPEAKER, EXIT SIGN, ETC. IN HEAVY DUTY T--BAR CEILING EQUIPMENT /FIXTURE MOUNTING DETAIL Pr . P T O / op / o O 00 NOTES: A 1. GYP BOARD, 5/8" THICK: 1HR. — 1 LAYER, 2HR. — 2 LAYERS. 2. FILL, VOID OR CAVITY MATERIAL — CAULK: CAULK FILL MATERIAL FORCED INTO ANNULAR SPACE TO MAX. EXTENT POSSIBLE AND WITH A MIN. 1/4" DIAMETER BEAD OF CAULK APPLIED TO PERIMETER OF PIPE OR CONDUIT AT ITS EGRESS FROM THE WALL MINNESOTA MINING & MANUFACTURING CO.: TYPES SP —25 S /L, CP —25 N /S. 3. CONDUIT: NOM. 4" DIAMETER (OR SMALLER) STEEL EMT CONDUIT OR NOM. 1" DIAMETER (OR SMALLER) FLEXIBLE STEEL CONDUIT. A MAX. OF ONE PIPE OR CONDUIT IS PERMITTED IN THE FIRESTOP SYSTEM. PIPE OR CONDUIT TO BE INSTALLED NEAR CENTER OF STUD CAVITY WIDTH AND TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 4. FIRESTOP SYSTEM: INSTALLED SYMMETRICALLY ON BOTH SIDES OF WALL ASSEMBLY. THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EITHER 1 OR 2 HR. DEPENDING UPON THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. THE HOURLY T RATING FOR THE FIRESTOP SYSTEM ARE DEPENDENT UPON THE SIZE OF THE CONDUIT, THE FIRESTOP CONFIGURATION AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. THE FIRESTOP CONFIGURATION IS DEPENDENT UPON THE SIZE OF THE ANNULAR SPACE BETWEEN THE STEEL PIPE OR CONDUIT (OR PIPE COVERING) AND THE PERIMETER OF THE CIRCULAR THROUGH OPENING IN THE GYPSUM WALLBOARD LAYERS. 5. ALL FIRE STOP SYSTEMS SHALL BE UL LISTED SYSTEMS APPROVED FOR USE WITH THE SIZE AND TYPE OF PENETRATION. OBTAIN UL SYSTEM REQUIREMENTS FROM FIRE STOP MATERIAL MANUFACTURER. RATED FIRE WALL, FLOOR OR CLG. RATED FIRE WALL, FLOOR OR CLG. SYSTEM WL-1001 F RATINGS — 1 AND 2 HR. SECTION A —A FOR FIRE RATED WALLS N.T.S. SLEEVE CONDUIT — SEE PLAN FOR SIZE & LOCATION INTUMESCENT PACKING AS REQUIRED TO MAINTAIN FIRE RATING OF ASSEMBLY SLEEVE — SEE PLAN FOR LOCATIONS FUTURE CABLE (N.I.C.) INTUMESCENT PACKING AS REQUIRED TO MAINTAIN FIRE RATING OF ASSEMBLY RATED PENATRATION DETAIL ANNULAR SPACE 1 1/4" C TO 4" C -1/4" MAX d 4-. UNISTRUT SUPPORT EAGLE #604 PORCELAIN LAMPHOLDER WITH AN EAGLE 469B METAL LAMP GUARD AND A 100A -19 LAMP. IF BUILDING STRUCTURE IS MORE THAN 7' -0" ABOVE FINISHED CEILING, INSTALL JUNCTION BOX AND LAMPHOLDER ON A 3/4" CONDUIT SUPPORT STUB EXTENDED DOWN SO LAMPHOLDER IS NO MORE THAN 7' -O" ABOVE FINISHED CEILING: LEVITON #5299 -I COMBINATION SINGLE POLE SWITCH AND GFCI OUTLET IN SWITCHBOX LOCATED BY CEILING ACCESS PANEL /AIR DEVICE. N.T.S. ALIGN BOTTOM OF FIXTURE WITH TOP OF RTU 3/4" RIGID GALVANIZED STEEL CONDUIT N.T.S. O NOTE: COORDINATE EXACT LOCATION OF RECEPTACLE & LIGHT WITH MECH. CONTR. SO AS NOT TO BLOCK ACCESS PANELS a VAV & AHU UNIT LIGHT RECEPTACLE DETAIL CU UNIT LIGHT RECEPTACLE DETAIL LIGHTING FIXTURE GENERAL NOTES STANCHION MOUNT LIGHT FIXTURE WITH GLOBE AND GUARD AND 100W. A -21 LAMP f ROOF OR FLOOR ABOVE. BLDG. STRUCTURE 3/4" SWITCH CONDUIT 3/4" CONDUIT TO 120 VOLT CIRCUIT. SEE FLOOR PLANS FOR CIRCUIT NUMBER. 3/4" RIGID GALVANIZED STEEL CONDUIT LEVITON #5299 -I COMBINATION SINGLE POLE SWITCH AND GFI OUTLET IN WEATHERPROOF SWITCH BOX ROUTE CONDUIT UP THRU OPENING FINISHED ROOF SURFACE ELECTRICAL DEVICE LEGEND ALL SYMBOLS DO NOT NECESSARILY APPLY SYMBOL DESCRIPTION �IG 34 EK C WIRED JUNCTION BOX WIRED JUNCTION BOX MOUNTING HGT. TO CENTERLINE UNLESS OTHERWISE NOTED DUPLEX RECEPTACLE, 3 WIRE GRD. TYPE, 20A DUPLEX RECEPTACLE, WEATHERPROOF,20A GROUND FAULT PROTECTED DUPLEX RECEPTACLE, 20A DUPLEX RECEPTACLE WITH ISOLATED GROUND QUADRAPLEX WALL RECEPTACLE, 20A DUPLEX RECEPTACLE, MOUNTED ABOVE COUNTER (1) ISOLATED GROUND RECEPTACLE AND ONE DUPLEX RECEPTACLE AS A QUADRAPLEX WALL RECEPTACLE FLOOR MOUNTED QUAD RECEPTACLE, 20A CEILING MOUNTED DUPLEX RECEPTACLE, 20A PUSHBUTTON STATION LOW VOLTAGE BUZZER TRANSFORMER DOOR BUZZER TOGGLE SWITCH - SINGLE, 3 -WAY & 4 -WAY SWITCHED CIRCUIT UNSWITCHED CIRCUIT MANUAL MOTOR STARTING SWITCH W/ PILOT LIGHT TELEPHONE OUTLET FLOOR MOUNTED TELEPHONE OUTLET DATA OUTLET - CATEGORY 5 DATA OUTLET - DUPLEX CATEGORY 5 SAFETY SWITCH MAGNETIC MOTOR STARTER COMBINATION STARTER /SAFETY SWITCH MOTOR OUTLET - 1 PHASE MOTOR OUTLET - 3 PHASE FIRE ALARM HORN /STROBE SIGNAL DEVICE CEILING MOUNTED FIRE ALARM HORN /STROBE SIGNAL DEVICE FIRE ALARM STROBE SIGNAL DEVICE W/CREMOT$NDICATORS KE DETECTOR FIRE ALARM PULL STATION SYSTEM SMOKE DETECTOR ® FIRE ALARM BOOSTER BOX KEY PAD CEILING MOUNTED MOTION SENSOR SEE DRAWINGS SEE DRAWINGS 18" 18" 18" 18" 18" 44" 18" 48" AS REQUIRED 54" 48" 48" 18" 18" 18" AS REQUIRED AS REQUIRED AS REQUIRED AS REQUIRED AS REQUIRED 80" 80" AS REQUIRED 48" CEILING MTD. 46" Nult: IN HANDICAPPED AREAS, THE RECEPTACLES AND TELEPHONE OUTLETS SHALL BE MOUNTED AT 24" A.F.F.; THE TOGGLE SWITCHES, THERMOSTATS AND MANUAL MOTOR STARTERS SHALL BE MOUNTED AT 42" A.F.F. A. ALL FIXTURES TO BE PROVIDED BY SEPHORA LIGHTING SUPPLIER. B. FIXTURES TYPES "FT ", "FU" AND "FU -1" AS INDICATED WITH CODED NOTE #4 ON THE SHEET E2.0, WILL BE SUPPLIED WITH EMERGENCY BATTERY PACKS TO PROVIDE 90— MINUTES OF EMERGENCY OPERATION. E 0a -583 FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. 2 1 1 APR 0 3 3 PROJECT LOCATION: AREA: 5,439 SF SHEET TITLE: PROJECT NO. SCALE: DATE: DRAWN BY: REVIEWED BY: SHEET NO. RECEIVED E APK 102008 PERMIT CENTER FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 TSAO _ JrclEA 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesign.com Ems On Fxeeaexe AA-Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 JOB #'0712121 Elks 07 J 11 l 09 I SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 981 18 ELECTRICAL DETAILS, SYVBOLS ADD LEGE DS 0712121 NONE 10 -08 -07 FJM DEG ELECTRICAL RESPONSIBILITY SCHEDULE .ext,rE.'D ft3 ht V C_ RELAY# FURNISHED BY INSTALLED BY RE -USE EXISTING VIN 1:L�Go�P,�t \ :Opt ai STIcii0--1.C1 ELEC. CONTR. LANDLORD SEPHORA OTHERS ELEC. CONTR. LANDLORD SEPHORA OTHERS MAIN OVERCURRENT DEVICE IN LANDLORD'S ELECTRIC ROOM Z11 - TRACK LIGHTING • R4 R5 A -5 • Z11 - TRACK LIGHTING A -6 R6 R7 Fj >` - PANEL BOARD CONDUIT TO SPACE Z11 - TRACK LIGHTING • R8 R9 A -9 • Z11 - TRACK LIGHTING A-10 R10 R11 A -11 PANELBOARD FEEDERS TO SPACE Z11 - TRACK LIGHTING • R12 R13 A -13 • Z1 - STORE FRONT UGHTTNG A -14 R14 R15 A -27 METER REQUIREMENTS Z1 - STORE FRONT LIGHTING • R16 R17 A -29 • Z12 - SPARE A -10 R18 R19 C -3 LIGHT FIXTURES AND LAMPS Z12 - SPARE Z11 - TRACK UGHTTNG • R21 • Z8 - GONDOLAS Z9 - BACK OF HOUSE LIGHTING -- ,3Q .1322 R24 6 - A - R23 C -7 OUTLETS AND SWITCHES • A -28 R25 C -9 • Z6 - 1/3 OF WALL DISPLAY - R27 C -11 Z8 - GONDOLAS 77 - 2/3 OF WALL DISPLAY GENERAL CONDUIT & WIRING • R29 C -13 Z8 - GONDOLAS • C -6 R30 R31 C -15 Z8 - GONDOLAS Z6 - 1/3 OF WALL DISPLAY TELEPHONE CONDUIT W/ PULL WIRE R32 • C -17 Z8 - GONDOLAS Z7 -- 2/3 OF WALL DISPLAY • R34 R35 C -19 Z8 - GONDOLAS Z6 - 2/3 OF WALL DISPLAY TELEPHONE CABLING • R37 C -21 Z8 - GONDOLAS • C -14 R38 R39 C -23 Z8 - GONDOLAS O TELEPHONE EQUIPMENT R40 R39 • Z8 - GONDOLAS Z5 - COVE LIGHTS C -18 • R39 C -27 Z8 - GONDOLAS Z5 - COVE LIGHTS DATA CONDUIT • R41 A-15 Z11 - CASH REGISTER SIGN • 20 21 SPARE RECEIVING (IG) Z12 - SPARE Z12 - SPARE DATA CABLING • 0.280 SPARE 0.000 • 23 22 23 24 LEARNING CENTER (IG O VIDEO /TV CONDUIT 0.360 C 0.000 24 SPARE 24 25 • FUTURE VIDEO /TV CABLING r. 0,. _ _ 0.180 A 0.000 . 27 SPARE SKIN CARE LIGHTS 26 • FUTURE TEMPORARY UTILITY CHARGES • 1.400 1.500 B • 29 SPACE INSTANT HOT DISP. - - - 28 29 TENANT ELECTRICAL PANELS • A 0.000 0.500 • 0.900 31 32 STORE FRONT RECEP. 30 TENANT ELECTRICAL TRANSFORMER • SPARE SPARE • A 0.900 GONDOLAS SPARE STORE FRONT RECEP. 0.700 TENANT FIRE ALARM SYSTEM • r.rir' MOTORIZED DAMPERS • 0.500 B 0.000 SPACE SPARE FLOOR BOXES 34 35 • SPARE • SPACE 0.000 C 0.000 0.000 B UGHTING CONTROL PANEL 36 • 6.890 • 41 SPARE 0.000 A 0.000 C UGHITNG CONTROL PANEL LOW VOLTAGE SWITCHES SPACE • 39 • SPACE 100/3 PANEL B 0.000 B 0.300 WALL MOUNTED OCCUPANCY SENSORS • FAP 40 • 6.620 SPACE 0.000 C RESPONSIBIUTY SCHEDULE CODED NOTES BY OTHERS. 0 ALL FINAL CONNECTIONS TO EQUIPMENT 02 SEE POWER RISER FOR ADDITIONAL INFORMATION. 0 PANEL NAME: R1 PANEL VOLTAGE = 120V RELAY# CKT # LIGHTING ZONE LIGHTING ZONE CKT # RELAY # R1 A -1 Z11 - TRACK LIGHTING Z11 - TRACK LIGHTING A -2 R2 R3 A-3 Z11 - TRACK LIGHTING Z11 - TRACK LIGHTING A -4 R4 R5 A -5 Z11 - TRACK LIGHTING Z11 - TRACK LIGHTING A -6 R6 R7 A -7 Z11 - TRACK LIGHTING Z11 - TRACK LIGHTING A -8 R8 R9 A -9 Z11 - TRACK UGHTING Z11 - TRACK LIGHTING A-10 R10 R11 A -11 Z11 - TRACK UGHTING Z11 - TRACK LIGHTING A -12 R12 R13 A -13 Z11 - TRACK LIGHTING Z1 - STORE FRONT UGHTTNG A -14 R14 R15 A -27 Z2 - ILLUMINATED MIRRORS Z1 - STORE FRONT LIGHTING A -16 R16 R17 A -29 Z10 - ANIMATION WALL Z12 - SPARE A -10 R18 R19 C -3 Z8 - GONDOLAS Z12 - SPARE Z11 - TRACK UGHTTNG R20 R21 C -5 Z8 - GONDOLAS Z9 - BACK OF HOUSE LIGHTING -- ,3Q .1322 R24 6 - A - R23 C -7 Z8 -- GONDOLAS Z9 - BACK OF HOUSE UGHTING A -28 R25 C -9 Z8 - GONDOLAS Z6 - 1/3 OF WALL DISPLAY - R27 C -11 Z8 - GONDOLAS 77 - 2/3 OF WALL DISPLAY C -4 R28 R29 C -13 Z8 - GONDOLAS Z7 - 2/3 OF WALL DISPLAY C -6 R30 R31 C -15 Z8 - GONDOLAS Z6 - 1/3 OF WALL DISPLAY C -8 R32 R33 C -17 Z8 - GONDOLAS Z7 -- 2/3 OF WALL DISPLAY C - 10 R34 R35 C -19 Z8 - GONDOLAS Z6 - 2/3 OF WALL DISPLAY C -12 R36 R37 C -21 Z8 - GONDOLAS Z6 -- 2/3 OF WALL DISPLAY C -14 R38 R39 C -23 Z8 - GONDOLAS Z6 - 1/3 OF WALL DISPLAY C -16 R40 R39 C -25 Z8 - GONDOLAS Z5 - COVE LIGHTS C -18 R42 R39 C -27 Z8 - GONDOLAS Z5 - COVE LIGHTS C -20 R44 R41 A-15 Z11 - CASH REGISTER SIGN Z12 - SPARE 20 21 SPARE RECEIVING (IG) Z12 - SPARE Z12 - SPARE 0.180 B ELECTRICAL CONNECTION SCHEDULE UNIT VOLTAGE FLA MCA MOCP A/POLE GROUNDED AND UNGROUNDED CONDUCTORS CONDUIT SWITCH DISCONNECT AT UNIT CIRCUIT CONNECTION NOTES VAV -1 480V, 3 PHASE 480V, 3 PHASE 20.83 20.83 27.44 27.44 20.5 30/3 30/3 25/3 (4) #10 THWN & (1) #10 GND (4) #10 THWN & (1) #10 GND (4) #10 THWN & (1) #10 GND 3/4" 3/4" 3/4" 30A, 3 -POLE, NONFUSED 30A, 3 -POLE, NONFUSED 30A, 3 -POLE, NONFUSED H- 7/9/11 CL2 VAV -2 H -8/10/12 H- 13/15/17 36 VAV -3 480V, 3 PHASE 16.43 4 VAV -4 480V, 1 PHASE 20.83 27.44 30/3 (4) #10 THWN & (1) #10 GND 3/4" 30A, 3 -POLE, NONFUSED H -2/4/6 8 PANEL NAME: R1 PANEL VOLTAGE = 120V CL CKT NO. PANEL CKT NO. Brkr. Size * CL BREAK AMPS UGHT1NG ZONE LIGHTING ZONE CL BREAK AMPS TRACK LENGTH FT. PANEL CKT NO. CL CKT NO. CL1 A -1 16 4 Z11 - TRACK UGHT1NG Z11 - TRACK LIGHTING 4 36 A -2 CL2 CL3 A -3 36 6 Z11 - TRACK UGHTING Z11 '--- TRACK LIGHTING 4 36 A -4 CL4 CL5 A -5 36 8 Z11 - TRACK UGHTING Z11 - TRACK LIGHTING 8 36 A -6 CL6 CL7 A -7 36 6 Z11 - TRACK UGHTING Z11 - TRACK UGHT1NG 8 36 A -8 CL8 CL9 A -9 36 8 Z11 - TRACK UGHTING Z11 - TRACK LIGHTING 6 36 A -10 CL1O CL11 A -11 36 8 Z11 - TRACK UGHTTNG Z11 - TRACK UGHTING 8 36 A -12 CL12 CL13 A -13 36 6 Z11 - TRACK UGHTING Z1 - STORE FRONT UGHTING 6 20 A -14 CL14 CL15 0.540 C 0.180 SPARE SPARE SCAN GUN (IG) GONDOLAS 12 CL16 CL17 ADMIN RECEP (IG) 1.050 SPARE SPARE 2.800 15 30 CL18 CL19 14 15 SPARE SPARE 0.100 B CL20 CL21 CONVENIENCE RECEP. C SPARE 17 --- MUX CAMERA POWER Lo (j Z Zone Load Description Brkr. Size * Brkr. Opts. N.E.C. kVA Phase N.E.C. kVA Brkr. Opts. � Load Description Zone Ckt No. r + M MW CASH REGISTER (IG) 03 -14 -08 to 0.360 A 0.850 0.000 02 -01 -08 REFRIGERATOR JAH 2 3 TRACK LIGHTING CASH REGISTER (IG) JAH Lo 0.360 B 1.130 ISSUE FOR PERMIT TRACK LIGHTING GARBAGE DISPOSAL [6],[7] stlm 5 TRACK LIGHTING CASH REGISTER (IG) L to 0.360 C 0.600 [8] TRACK LIGHTING MICROWAVE MISCELLANEOUS 7 - FEEDER AMPERAGE AMPS CASH REGISTER (IG) 6.000 _- 104.563 to 0.360 A 0.360 Lo 208 X 1.732 TEL/DATA BOARD (IG) 9 8 9 CASH REG. RECEP. 0.700 B 0.360 B 0.360 LO 10 TEL/DATA BOARD 10 11 ADMIN RECEP (IG) C 1.500 0.540 C 0.180 12 14 SCAN GUN (IG) GONDOLAS 12 13 1.400 1.400 ADMIN RECEP (IG) 1.050 0.360 A 2.800 15 30 UPS TWIST LOCK (IG) 14 15 LTG. CONTROL PANEL 1/3 WALL DISPLAY 0.100 B 1.200 CONVENIENCE RECEP. C 16 17 MUX CAMERA POWER Lo 1.200 C 1.260 1.400 CONVENIENCE RECEP. 0.704 18 19 COVE LTS EMPLOYEE TIMECLOCK 20 0.180 A 0.540 1.400 SPARE CONVENIENCE RECEP. 20 20 21 SPARE RECEIVING (IG) 23 0.000 0.180 B 0.280 SPARE 0.000 TF -1, EF -1 23 22 23 24 LEARNING CENTER (IG 0.900 C 0.360 C 0.000 24 SPARE 24 25 GONDOLAS A r. 0,. _ _ 0.180 A 0.000 . 27 SPARE SKIN CARE LIGHTS 26 27 0.300 EWH -1 20/2 1.400 1.500 B 0.750 29 SPACE INSTANT HOT DISP. - - - 28 29 C HVAC CONTROL PANEL A 0.000 0.500 C 0.900 31 32 STORE FRONT RECEP. 30 31 0.000 SPARE SPARE 0.000 A 0.900 GONDOLAS SPARE STORE FRONT RECEP. 0.700 32 33 r.rir' MOTORIZED DAMPERS ' ' 0.500 B 0.000 SPACE SPARE A 34 35 0.000 SPARE SPACE 0.000 C 0.000 0.000 B SPARE 36 37 6.890 SPARE 41 SPARE 0.000 A 0.000 C PANEL C SPACE 38 39 7.020 SPACE 100/3 PANEL B 0.000 B 0.300 Lo FAP 40 41 6.620 SPACE 0.000 C 0.720 MECHANICAL RECEP. 42 Ckt No. Zone Load Description I m Brkr. Opts. N.E.C. kVA ** Phase N.E.C. kVA ** Brkr. Opts. Brkr. Size * Load Description Zone Oct No. r + M MW TRACK LIGHTING 03 -14 -08 REVISION 0.270 A 0.300 0.000 02 -01 -08 TRACK LIGHTING JAH 2 / I \ TRACK LIGHTING CITY COMMENTS RE- SUBMITTAL JAH 0.390 B 0.120 10 -08 -07 ISSUE FOR PERMIT TRACK LIGHTING WPK [6],[7] 5 CLIENT /PRELIM. LL REVIEW TRACK LIGHTING WPK L 0.480 C 0.600 CHECK [8] TRACK LIGHTING 3.038 MISCELLANEOUS 7 - FEEDER AMPERAGE AMPS TRACK LIGHTING 6.000 _- 104.563 N.E.C. DEM. KVAX 1000 0.450 A 0.660 SYS. VOLTAGE X 1.732 104.563 X 1000 208 X 1.732 TRACK LIGHTING 9 8 9 TRACK LIGHTING 0.700 B 0.480 B 0.270 10 TRACK LIGHTING 10 11 TRACK LIGHTING C 1.500 0.510 G 0.510 12 14 TRACK LIGHTING GONDOLAS 12 13 1.400 1.400 TRACK LIGHTING 1.050 0.390 A 0.420 15 GONDOLAS STORE FRONT LTS 14 15 CASH REG. SIGN 1/3 WALL DISPLAY 0.400 B 0.100 ENTRY LTS C 16 17 SPARE 18 0.000 C 0.000 1.400 SPARE 0.704 18 19 COVE LTS SPARE 20 0.000 A 0.000 1.400 SPARE 0.000 20 21 SPARE SPARE 22 23 0.000 B 0.000 1.400 1.400 SPARE 0.000 22 23 SPARE NUEM SALES 24 Lo 0.900 C 0.000 A SPARE 24 25 ILLUMINATION MIRROR 27 GONDOLAS 0.600 A r. 0,. _ _ B S - • - . 27 SKIN CARE LIGHTS 29 31 33 35 _ = 0.300 B 1.024 1.400 NON -SALES LTS 0.000 28 29 SPACE SPARE - - - SPARE 0.000 C 0.574 A 0.000 NON /SALES LTS 30 31 32 SIGN 1.200 A 0.000 0.000 SPARE SPACE 32 33 GONDOLAS SPARE 0.700 0.000 B r.rir' ' ' w It 35 SPACE 0.000 A 0.000 C 0.000 SPACE SPACE SPARE 36 37 0.000 B 0.000 10.754 A 6.890 40 41 SPARE 38 39 C PANEL C 125x3 11.150 B 7.020 100/3 PANEL B 40 41 10.950 C 6.620 42 A\ 04 -03-08 REVISION JAH WPK /4\ 03 -27-08 REVISION JAH WPK /3\ 03 -19 -08 REVISION RL MW h\ \ 03 -14 -08 REVISION JAH WPK KIT APPLIANCE 0.000 02 -01 -08 ISSUE FOR BID JAH WPK / I \ 11 -12 -07 CITY COMMENTS RE- SUBMITTAL JAH WPK 0.280 [6] 10 -08 -07 ISSUE FOR PERMIT JAH WPK [6],[7] 07 -27 -07 CLIENT /PRELIM. LL REVIEW JAH WPK L DATE ISSUE DESCRIPTION BY CHECK ELECTRIC LOAD SUMMARY (TRANSFORMER) 208Y/120V LOADS DESCRIPTION N.E.C. CONNECTED kVA NEC DEMAND NOTES N.E.C. DEMAND FACTOR N.E.C. DEMAND kVA - 54.753 LIGHTING (CONTINUOUS) 43.802 [1] 1.25 TRACK LIGHT DEMAND ALLOWANCE - [2] 24.038 24.038 SHOW WINDOW DEMAND ALLOWANCE - [3] - 5.475 KIT APPLIANCE 0.000 [4 1.00 0.000 RECEPTACLES 11.820 [5] - 10.910 MOTORS 0.280 [6] - 0.350 FIXED ELECTRIC SPACE HEATING 0.000 [6],[7] - 0.000 AIR CONDITIONING SYSTEM 0.000 [6].[7] - 0.000 ELECTRIC WATER HEATER 2.430 [8] 12 3.038 MISCELLANEOUS 6.000 64.332 - FEEDER AMPERAGE AMPS 1.0 6.000 _- 104.563 N.E.C. DEM. KVAX 1000 TOTAL = MINIMUM = 2902 = MINIMUM = 189.1 SYS. VOLTAGE X 1.732 104.563 X 1000 208 X 1.732 ELECTRIC LOAD SUMMARY 480Y/277V SYSTEM DESCRIPTION N.E.C. CONNECTED kVA NEC DEMAND NOTES N.E.C. DEMAND FACTOR N.E.C. DEMAND kVA LIGHTING (CONTINUOUS) 43.802 [1] [2] 1.25 - 54.753 _ _ WA TRACK LIGHT DEMAND ALLOWANCE w Ckt No. 24.038 SHOW WINDOW DEMAND ALLOWANCE - [3] - 5.475 KIT APPLIANCE 0.000 [4 1.00 0.000 RECEPTACLES 11.820 [5] 10.910 MOTORS 0.280 [6] - 0.350 FIXED ELECTRIC SPACE HEATING 0.000 [6].[7) - 0.000 AIR CONDITIONING SYSTEM 49.415 [ - 52.640 ELECTRIC WATER HEATER 2.430 [8] 1.2 3.038 MISCELLANEOUS 6.000 - J FEEDER AMPERAGE AMPS 1.0 6.000 TOTAL N.E.C. DEM. KVA X 1000 113.747 TOTAL 157.203 = MINIMUM = 189.1 1/3 WALL DISPLAY SYS. VOLTAGE X 1.732 157.203 X 1000 480 X 1.732 Cid. No. Zone Load Description Brkr. Size Brkr. Opts. N.E.G. kVA Phase N.E.C. kVA Brkr. Opts. Brkr. Size • Load Description Zone Ckt No. 1 GONDOLAS 0.700 A 1.200 1/3 WALL DISPLAY 2 3 GONDOLAS 1.400 B 1.500 2/3 WALL DISPLAY 4 5 GONDOLAS 1.400 1.400 C 1.200 2/3 WALL DISPLAY 6 GONDOLAS A 1.500 1.500 1/3 WALL DISPLAY 8 9 GONDOLAS 0.700 B 2/3 WALL DISPLAY 10 11 GONDOLAS 1.400 C 1.500 2/3 WALL DISPLAY 12 14 13 GONDOLAS 1.400 1.400 A 1.050 2/3 WALL DISPLAY 15 GONDOLAS B 0.450 1/3 WALL DISPLAY 16 17 GONDOLAS 1.400 C 0.550 COVE LTS 18 19 GONDOLAS 1.400 A 0.704 COVE LTS 20 21 GONDOLAS 1.400 B 0.000 SPARE 22 23 GONDOLAS 1.400 1.400 C 0.000 SPARE 24 25 GONDOLAS A 0.000 SPARE 26 27 GONDOLAS 1.400 B 0.000 SPARE 28 29 31 33 35 _ = GONDOLAS 1.400 C 0.000 SPACE 30 SPARE 0.000 A 0.000 SPACE 32 GONDOLAS 1.400 B 0.000 SPACE 34 GONDOLAS 0.700 C 0.000 SPACE 36 38 37 SPARE 0.000 A 0.000 SPACE 39 SPARE 0.000 B 0.000 SPACE 40 41 SPARE 0.000 C 0.000 SPACE 42 5 5 4 NOTE: LANDLORD TO PROVIDE 4 #350MCM AND 1 #1/0 GRD. IN LANDLORD PROVIDED 3" CONDUIT. TENANT PROVIDED 1" CONDUIT FOR TELECOMMUNICATIONS. CONDUIT SHALL BE TERMINATED AT LANDLORD CABLE TRAY LOCATED IN SERVICE CORRIDOR. VERIFY EXACT LOCATION PRIOR TO BIDDING.- LANDLORD SHALL PROVIDE 300A /3P CIRCUIT BREAKER IN LANDLORD'S SWITCH GEAR.-- EXISTING 277/480V, 30, 4W, LANDLORD SWITCHBOARD LOCATED IN ELECTRICAL ROOM. FIELD VERIFY EXACT REQUIREMENTS PRIOR TO BIDS. A HVAC CIRCUIT BREAKERS SHALL BE "HACR" TYPE WHERE REQUIRED BY EQUIPMENT NAMEPLATE PER N.E.C. B TENANT'S ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXACT A.I.C. RATING OF LANDLORD'S DISTRIBUTION EQUIPMENT, FURNISH AND INSTALL TENANTS SYSTEM TO MATCH. C ELECTRICAL CONTRACTOR SHALL BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT TO ±10% BETWEEN PHASES: A/B B /C, A/C REGARDLESS OF CIRCUITING INDICATED. D PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.C. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. E ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. F TENANT'S NAME AND SPACE NUMBER SHALL BE APPUED TO DISCONNECT SWITCH AT SWITCHGEAR WITH BLACK PLASTIC LAMENT WITH WHITE LETTERS. G TENANT'S ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BID. Panelboard Panel Type NEMA Type Notes FINAL CONNECTION TO SWITCHGEAR BY LANDLORDS E.C. AT TENANTS EXPENSE METER AND METER SOCKET PER POWER CO. REQUIREMENTS. FLOOR "A" N000 1 All circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted. All Phases to be balanced to within 10% using Actual Load Totals. N.E.C. Connected Totals: Ph.A N.E.C. Connected Totals: Ph.B N.E.C. Connected Totals: Ph.0 Total E Existing Circuit to remain IG Isolated Ground Circuit Connected Load: NEC 2005 Demand Feeder Load: Panelboard Panel Type NOOD NEMA Type 1 E Existing Circuit to remain IG Isolated Ground Circuit Voltage OCPD Mounting 300A 208Y/120 400A M.C.B. SURFACE Voltage 208Y/120 OCPD M.L.Q. Mounting SURFACE Notes * All circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted. All Phases to be balanced to within 10% using Actual Load Totals. N.E.C. Connected Totals: Ph.A N.E.C. Connected Totals: Ph.B N.E.C. Connected Totals: Ph.0 Total LL'S ELECTRIC RM Phase Wire Buss 21.934 21.254 21.144 64.332 178.6 290.1 10.754 11.150 10.950 32.854 Connected Load: 91.2 NEC 2005 Demand Feeder Load: 114.0 5 3 4 400A kVA kVA kVA kVA amps amps Phase 3 Wire 4 Buss 225A kVA kVA kVA kVA amps amps APPROX. 125' VERIFY EXACT DISTANCE) LEASE LINE Options/Notes AIC Rang Options/Notes AIC Rating TELEPHONE BOARD TENANT SPACE Breaker Options: AS Powerlink AS Breaker LO Handle lock -on device ST Shunt Trip Type AUX Auxiliary Contacts PA Handle Padlock Attachment GFCI Ground Fault Circuit Interrupter HACR Heating, NC & Refrigeration SF Subfeed AFCI Arc Fault Circuit Interrupter Breaker Options: AS Powerlink AS Breaker LO Handle lock -on device ST Shunt Trip Type AUX Auxiliary Contacts PA Handle Padlock Attachment GFCI Ground Fault Circuit Interrupter HACR Heating, NC & Refrigeration SF Subfeed AFCI Arc Fault Circuit Interrupter 10,000 10,000 ■ 4 #350MCM AND 1 #1/0 GRD. IN 3" CONDUIT. LANDLORD PROVIDED 400A /3P FUSED DISCONNECT SWITCH, WITH LANDLORD PROVIDED 300A FUSES. TENANT TO RELOCATE IF REQUIRED, AND EXTEND WIRE AND CONDUIT AS NEEDED. 112.5 KVA TRANSFORMER 480V, 30 DELTA PRI. 120/ 208V, 30, 4W WYE SEC. - POWER RISER DIAGRAM NTS POWER RISER GENERAL NOTES: ALL NEW TERMINATIONS SHALL BE 75' C RATED O POWER RISER CODED NOTES: Panelboard Panel Type NEMA Type PANEL "HP" 277/480V. 30, 4W, 300A M.C.B. 1 MASTER LIGHTING CONTROL PANEL PROVIDED BY LIGHTING SUPPLIER. SEE RELAY CONTROL PANEL SCHEDULE, THIS SHEET, FOR WIRING AND ZONE REQUIREMENTS. PROVIDE (1) CAT5 CONTROL CABLE BETWEEN THE MASTER AND THE SLAVE LIGHTING PANEL. 2 REFER TO "CURRENT LIMITING DETAIL ", THIS SHEET FOR MORE INFORMATION. 'B" N00D E Existing Circuit to remain IG Isolated Ground Circuit 2" MIN. PANEL "B" 120/208V, 30, 4W FED FROM PANEL "A" 3 #2/0 THWN AND 1 #6 GRD. IN 2" CONDUIT. VERIFY EXACT OVER CURRENT PROTECTION /DISCONNECT REQUIREMENTS (PER N.E.G. #440) WITH EQUIPMENT MANUFACTURER NAMEPLATE DATA UPON RECEIPT AT JOB SITE. CONTACT ENGINEER WITH ANY DISCREPANCIES. ELECTRICAL CONTRACTOR TO MAKE ALL FINAL ELECTRICAL POWER CONNECTIONS. Voltage OCPD Mounting MICARTA LABEL TYIPICAL FOR ALL PANELS 208Y/120 M.L.O. SURFACE Connected Load: 57.0 NEC 2005 Demand Feeder Load: 56.1 4" MIN. Notes • All circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted. All Phases to be balanced to within 10% using Actual Load Totals. N.E.C. Connected Totals: Ph.A 6.890 N.E.C. Connected Totals: Ph.B 7.020 N.E.C. Connected Totals: Ph.0 6.620 Total 20.530 PANEL " 120/208V, 30, 4W, 400A M.C.B. 4 #600 MCM 4 #3 THWN, 1 #8 GRD. THWN AND 1 AND 1 #8 ISOLATED GRD. #1/0 GRD. IN IN 1-1/2" CONDUIT. 3 -1/2" CONDUIT. #1/0 GRD. TO BLDG. STEEL PER NEC. CURRENT LIMITING PANEL GENERAL NOTES 1. CURRENT UMITING PANEL PROVIDED BY OWNERS UGHTING FIXTURE SUPPUER. PANEL SHALL BE LC &D T24CL 21 CIRCUIT SILVER BULLET PANEL. 2. THE CIRCUITING SHOWN ON THE PLAN CORRESPONDS TO THE LIGHTING CONTROL SCHEME, IF THE CIRCUITING IS CHANGED IN THE FIELD THE ELECTRICAL CONTRACTOR SHALL CONTACT THE ENGINEER AND NOTIFY THEM OF THE CHANGES IN WRITING. 3. ROUTE ALL TRACK LIGHTING CIRCUITS FROM BREAKER PANEL TO CURRENT UMITING PANEL LANDING EACH TRACK ON THE INPUT SIDE OF THE SUPPLEMENTARY BREAKER DESIGNATED BY LC &D. WIRE FROM THE OUTPUT SIDE OF EAC SUPPLEMENTARY BREAKER TO THE MASTER LCP. LANDING EACH CIRCUIT ON THE LINE TERMINAL DESIGNATED BY LC &D. ALL OTHER UGHTING CIRCUITS SHALL BE ROUTED THROUGH LCP PER MFG. SCHEDULE. Phase 3 Wire 4 Buss 225A kVA kVA kVA kVA amps amps LC &D CURRENT LIMITING PANEL. Options/Notes AIC Rating 4 #1 THWN, AND 1 #6 GRD. IN 1-1/2" CONDUIT. 0 Breaker Options: AS Powerlink AS Breaker LO Handle lock -on device ST Shunt Trip Type AUX Auxiliary Contacts PA Handle Padlock Attachment GFCI Ground Fault Circuit Interrupter HACR Heating, NC & Refrigeration SF Subfeed AFCI Arc Fault Circuit Interrupter MASTER LC &D LIGHTING CONTROL PANEL. O 10,000 an board Panel Type NEMA Type Ckt No. Zone 1 3 5 9 11 13 15 17 19 21 23 25 27 29 VAV -1 VAV -3 HP" NF Load Description TRANSFORMER 175/3 Voltage •:'Yr2 OCPD 300A M.C.B. Mounting Brkr. Brkr. N.E.C. Size Opts. kVA 30/3 SURFACE 6.075 3.330 3.330 3.330 25/3 3.330 4.550 0.000 0.000 0.000 0.000 A 0.000 B 0.000 21.934 21.254 21.144 Phase A C A B C Notes • All circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted. • All Phases to be balanced to within 10% using Actual Load Totals. N.E.C. Connected Totals: Ph.A N.E.C. Connected Totals: Ph.B N.E.C. Connected Totals: Ph.0 Total E Existing Circuit to remain IG Isolated Ground Circuit Connected Load: NEC 2005 Demand Feeder Load: 'hose 3 Wire 4 Buss 450A N.E.C. kVA 3.330 6.075 3.330 3.330 3.330 6.075 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 136.8 189.1 Brkr. Opts. 37.999 kVA 37.319 kVA 38.429 kVA 113.747 kVA Brkr. Size 30/3 amps amps O.,o otes AIC Rating VAV -2 VAV-4 Breaker Options: Load Description Zone AS Powerlink AS Breaker LO Handle lock -on device ST Shunt Trip Type AUX Auxiliary Contacts PA Handle Padlock Attachment GFCI Ground Fault Circuit Interrupter HACR Heating, A/C & Refrigeration SF Subfeed AFCI Arc Fault Circuit Interrupter 14,000 Ckt No. 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 PANEL "C" 120/208V, 30, 4W, 225A M.L.0 n PANEL " 120/208V, 30, 4W, 225A M.L.O. FLOOR CURRENT LIMITER PANEL PANEL "A" 0 O LV RELAY PANEL NOTES 1 LOW VOLTAGE UGHTING CONTROL PANEL PROVIDED BY OWNERS' LIGHTING FIXTURE SUPPLIER. LOW VOLTAGE LIGHTING CONTROL SYSTEM COMPLETE WITH PROGRAMMABLE TIME CLOCK, LV RELAYS, AND LV MASTER CONTROL SWITCHING. REFER TO SCHEDULE AND PARTIAL RISER DIAGRAM FOR CONTROL ZONING AND CAPACITY. 2 THE CIRCUITING SHOWN ON THE PLAN CORRESPONDS TO THE LIGHTING CONTROLS SCHEME. IF THE CIRCUITING IS CHANGED IN THE FIELD THE ELECTRICAL CONTRACTOR SHALL CONTACT THE ENGINEER AND NOTIFY THEM OF THE CHANGES IN WRITING. 3 ELECTRICAL CONTRACTOR SHALL COORDINATE WITH SEPHORA AND MALL LANDLORD FOR PROGRAMMING TIMECLOCK SCHEDULES. THE ELECTRICAL CONTRACTOR SHALL PROVIDE THE GENERAL CONTRACTOR WITH THE OPERATIONS MANUAL AFTER THE JOB IS COMPLETE. A COPY OF THE RELAY SCHEDULE WITH ANY HELD CONDITION CHANGES IDENTIFIED SHALL BE LEFT IN THE DOOR OF THE LC &D RELAY PANEL 4 ELECTRICAL CONTRACTOR SHALL CALL LC &D TO PERFORM DIAGNOSTIC TEST AT COMPLETION OF INSTALLATION. CURRENT UMITING BREAKER PANEL OUT TO LIGHTING LOADS T T TC 11 'P LIGHTING CONTROL PANEL 0 IMO MIM ■ M IMIIMI CURRENT LIMITING PANEL CODED NOTES 1. ROUTE ALL TRACK UGHTING CIRCUITS FROM BREAKER PANEL TO T24CL LANDING EACH TRACK CIRCUIT ON THE INPUT SIDE OF THE SUPPLEMENTARY BREAKER DESIGNATED BY LC &D. 2. WIRE FROM THE OUTPUT SIDE OF EACH SUPPLEMENTARY BREAKER TO THE MASTER LCP, LANDING EACH CIRCUIT ON THE LINE TERMINAL DESIGNATED BY LC &D. 3. ROUTE ALL OTHER LIGHTING CIRCUITS THROUGH LCP PER SCHEDULE. 4. 4" X 4" X 60" GUTTER MOUNTED BELOW OR ABOVE PANELS. C CURRENT LIMITING PANEL DIAGRAM N.T.S LOAD SUMMARY NOTES: [1l [ [3] [4] [5] [ m [81 POWER FACTOR IS ALREADY INCLUDED IN LIGHTING LOAD. 150VA/2FT OF LINE VOLTAGE TRACK + SUM LOW VOLTAGE XFRMS - CONNECTED LOAD 200VA/LF - ACTUAL CONNECTED LOAD KIT APPLIANCE DEMAND FACTOR PER NEC 220-20 0.0 < 10KW = 100%, REMAINING - 50% 125% OF THE LARGEST MOTOR OR COMPRESSOR IN SYSTEM APPUED ON ONE UNIT. USE GREATER VALUE OF THESE TWO CATEGORIES 125% DEMAND FACTOR FOR TANK TYPE, 100% FOR INSTANT HOT LIGHTING ZONES Z1 - STORE FRONT LIGHTING Z2 - WALL MOUNT SALES Z3 - "5" DOXES AND Z4 - SIGNS AND EXTERIOR LIGHTING Z5 - COVE LIGHTING /REAR SKIN CARE Z6 - 1/3 OF WALL DISPLAY Z7 - 2/3 OF WALL DISPLAY Z8 - GONDOLAS /LIGHTED MIRRORS Z9 - BACK OF HOUSE LIGHTING Z10 - ANIMATION WALL Z11 - TRACK LIGHTING Z12 - SPARE STAFF UGHT1NG SHALL CONSIST OF: Z1 - STORE FRONT LIGHTING Z3 "S" BOXES & BLADE CICNS Z5 - COVE LIGHTING Z6 - 1/3 OF WALL DISPLAY Z9 - BACK OF HOUSE LIGHTING MASTER CONTROL IN ELECTRICAL AREA z1 Z2 Z3 Z7 STAFF LIGHTING 0 ALL OFF U ENTRANCE CONTROL SWITCHES AT STAGE DOOR (SW1) 1 LANDLORD NOTES: ELECTRICAL CONTRACTOR SHALL UTILIZE LANDLORD PROVIDED FUSED DISCONNECT SWITCH LOCATED WITHIN THE TENANT SPACE FOR TEMPORARY ELECTRIC FOR CONSTRUCTION. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY TRANSFORMER AND PANEL AS REQUIRED WITHIN TENANT SPACE. 2 LANDLORD PROVIDED MASTER METERING EQUIPMENT IN THE LANDLORD'S ELECTRICAL ROOM. THE LANDLORD OWNED NETWORK METERING SYSTEM WILL METER TENANT POWER CONSUMPTION. 0 0 0 0 0 0 0 0 0 0 0 0 Z8 Z9 Z4 Z5 Z6 Z10 211 Z12 CATAGORY 5, 4 TW PAIR J BY ELEC. CONTRACTOR FROM BRANCH CIRCUIT PANEL 20"Wx38 "Hx6 "D MASTER LIGHTING CONTROL PANEL GR2400 I"1 TO LIGHTING LOADS NOTE: ELECTRICAL CONTRACTOR SHALL TERMINATE ALL CAR -5 CABLE FROM SEITCHES TO TERMINALS IN LC &D PANEL mommimm MASTER LIGHTING CONTROL PANEL LV RELAY PANEL DIAGRAM N.T.S Sg FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. AREA: SHEET TITLE: SCALE: DATE: TSAO DRAWN BY: REVIEWED BY: SHEET NO. RECEIVED APR 102008 PERMIT CENTER FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f Www.tsaodosign.com Emphasis On Excel M- Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 APR 0 3 20C3 PROJECT LOCATION: JOB l0712121 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 98118 POWER RISER & SCHEDULES PROJECT NO. 0712121 E5.0 5,439 SF NONE 10 -08 -07 FJM DEG 4 3 3 2 2 1 1 B L c- t - - I'� _ - ,- 5 5 4 4 3 3 2 2 1 BUILDING CORRIDOR I 112.5KVA TRANSFORMER 1 1 <VA RM T;AN`. - • -MI= I ^ r III Ili a PANEL �tAVr__ I I NETWORK --1 : -� �C-F -H LC r L B I18 1 8 -40 I .__1 ANEL "C 36 "x12" 36 "x 12' 36 "x 12" B -25/27 ( B -18 C -14,16 C-14 C —L -- -- L__ 4W 4a��i�ri�rr/ Il l PANEL "H" PANEL "B" B -10 B _ 8 B -14 LOW VOLTAGE WRING SPECIFICATIONS (USING CAT -5 WIRING) 1 FROM CASHWRAP TO TEL /DATA TERMINAL BOARD - FOUR CABLES PER REGISTER LOCATION AND TWO SPARE (18 CABLES TOTAL PER TYPICAL 4 REGISTER CASHWRAP AND 28 CABLES TOTAL PER 6 SECTION CASHWRAP (4 SPARE)). A 20 FOOT SERVICE LOOP AT EACH CASHWRAP CONDUIT STUB IS REQUESTED. SEE DETAIL D SHEET E3.0. 2 FROM OFFICE LOCATION TO TEL/DATA TERMINAL BOARD- 4 INDIVIDUAL DROPS BELOW COUNTERTOP. A THREE FOOT SERVICE LOOP AT EACH DATA JACK IN OFFICE AND A 20' SERIVCE LOOP AT THE TEL /DATA TERMINAL BOARD 3 FROM RECEIVING DESK LOCATION TO TEL /DATA TERMINAL BOARD ONE DROP (FOUR CABLES PER DROP). A THREE FOOT SERVICE LOOP AT RECEIVING DESK LOCATION AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 4 FROM TIME AND ATTENDANCE DEVICE (BY OFFICE DOOR) TO TEL/DATA TERMINAL BOARD- ONE DROP (TWO CABLES PER DROP). A THREE FOOT SERVICE LOOP AT TIME AND ATTENDANCE LOCATION AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 5 FROM BURGLAR ALARM BOX TO TEL /DATA TERMINAL BOARD- ONE DROP (ONE CABLE PER DROP). A THREE FOOT SERVICE LOOP AT THE BURGLAR ALARM AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 6 FROM UGHTING CONTROL PANEL TO TEL /DATA TERMINAL BOARD- ONE DROP (ONE CABLE PER DROP). A SIX FOOT SERVICE LOOP AT THE UGHTING CONTROL PANEL LOCATION AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 7 FROM FIRE ALARM BOX TO TEL /DATA TERMINAL BOARD- ONE DROP (ONE CABLE PER DROP). A THREE FOOT SERVICE LOOP AT THE FIRE ALARM LOCATION AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 8 IF CONDUIT TERMINATES AT TELEPHONE TEL /DATA TERMINAL BOARD, A 20 FOOT SERVICE LOOP SHALL BE MEASURED FROM THE END OF THE CONDUIT. 9 IF CONDUIT DOES NOT TERMINATE AT TFI FPHONE TEL /DATA TERMINAL BOARD, CABLE LENGTH SHOULD BE SUFFICIENT TO EXTEND TO THE MIDDLE OF THE BACKBOARD, THEN ADD A 20 FOOT SERVICE LOOP. 10 FROM FRONT DOOR HEADER ABOVE CEILING TO TEL /DATA TERMINAL BOARD- ONE DROP (2 CABLES PER DROP). A 25 FOOT SERVICE LOOP AND TIE OFF TO THE STRUCTURE FOR FUTURE PEOPLE COUNTER, AND A 20' SERIVCE LOOP AT TEL/DATA TERMINAL BOARD IS REQUESTED. 11 FROM SECURTIY (OVER SAFE) TO TEL /DATA TERMINAL BOARD- ONE DROP (4 CABLES PER DROP). A THREE FOOT SERVICE LOOP AT THE SECURITY END AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 12 UGHTING CONTROL PANEL TO HAVE A DEDICATED PHONE UNE FOR REMOTE ACCESS. CONTRACTOR IS TO ROUTE A DEDICATED RJ-11 PHONE CABLE TO LC&D CONTROL PANEL AND MAKE THE TERMINATION. 13 HVAC CONTROL PANEL TO HAVE A DEDICATED PHONE UNE AND DATA LINE FOR REMOTE ACCESS. CONTRACTOR IS TO ROUTE A DEDICATED RJ-11 PHONE CABLE AND A DEDICATED RJ -45 CABLE TO HVAC CONTROL PANEL AND MAKE THE TERMINATION. NOTE: ALL CONDUIT AND WIRE MATERIALS TO BE PROVIDED BY ELECTRICAL CONTRACTOR. 11 12 TYP C -2,4,6 ( LMT PROVIDE DUPLEX RECEPTACLE AND DATA FOR EMPLOYEE TIME CLOCK. VAV -4 CODED NOTES: 0 PROVIDE A DUPLEX RECEPTACLE, MOUNTED HORIZONTALLY AT 4" AF.F. FOR WINDOW DISPLAY. ® PROVIDE (2) 1" CONDUITS FOR SECURITY SYSTEM RACEWAY. STUB ONE END OF CONDUITS 46" A.F.F, AND THE OTHER END ABOVE THE CEILING, IN THE SECURITY OFFICE. PROVIDE PULL BUSHINGS ON ALL CONDUIT ENDS AND PULL STRINGS IN EACH. SEE DETAIL E, SHEET E3.0. FOR MORE INFORMATION. 10 CONTRACTOR IS TO VERIFY THE USE OF A SIX SECTION OR A FOUR SECTION AND SEE "CASH WRAP CONDUIT AND WRING" DETAIL D ON SHEET E3.0 FOR ELECTRICAL REQUIREMENTS AND CIRCUITING IN THIS AREA. PROVIDE A J -BOX FOR SECURITY M0110N DETECTOR. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH SECURITY INSTALLER. LOCATION OF THERMOSTAT OR SENSOR. COORDINATE EXACT LOCATIONS, MOUNTING HEIGHTS AND QUANTITY WITH MECHANICAL AND ARCHITECTURAL PLANS. PROVIDE A JUNCTION BOX, MOUNTED HORIZONTALLY, AND STUB A 3/4" CONDUIT, WITH A PULL STRING, ABOVE THE CEILING FOR EACH DEVICE. PROVIDE A DUPLEX RECEPTACLE MOUNTED BELOW SINK, FOR THE GARBAGE DISPOSAL. RECEPTACLE SHALL BE CONTROLLED BY WALL MOUNTED SWITCH. C- 3,5,23 - -- T■\ C =3 ® PROVIDE CONNECTION TO WALL MOUNTED DISPLAY UNITS. SEE DETAIL C, SHEET E3.O FOR ADDITIONAL CONNECTION REQUIREMENTS. ®3 PROVIDE A JUNCTION BOX FOR FUTURE PEOPLE COUNTER. PROVIDE A TWENTY FOOT SERVICE LOOP OF CABLE AND TIE OFF TO THE STRUCTURE FOR FUTURE USE. ® PROVIDE CONNECTION TO HOT WATER HEATER. COORDINATE LOCATION IN THE FIELD WITH PLUMBING CONTRACTOR. ® CONDUIT SAW -CUT OR CORE DRILLED IN FLOOR. VERIFY REQUIREMENTS FOR SAW - CUTTING OR CORE DRILLING WITH LANDLORD. ROUTE CONDUIT TO NEAREST ACCESSIBLE WALL AND RISE UP TO CEILING. ® MASTER LIGHTING CONTROL PANEL. CONNECT TO CIRCUIT B -15. SEE SCHEDULE ON SHEET E5.0. ® PROVIDE RECESSED DUPLEX FLOOR RECEPTACLE AT GONDOLA. CENTER UNDER 3 SECTION AND THE 1 SECTION GONDOLAS. OFFSET UNDER 2 SECTION GONDOLA. ELECTRICAL CONTRACTOR TO PROVIDE CORD AND PLUG CONNECTION FROM CENTER J -BOX. PROVIDE CONDUIT AND WIRE CONNECTIONS BETWEEN MANUFACTURER SUPPLIED J -BOXES IN GONDOLA SECTIONS. CONTRACTOR IS TO VERIFY THE SLAB TYPE AND REFER TO DETAILS A AND H ON SHEET E3.0. GONDOLAS WITH MAKE -UP MIRROR WILL BE SUPPLIED WITH A WHIP THAT SHALL BE CONNECTED INTO THE JUNCTION BOX OF THE GONDOLA. COORDINATE WITH ARCHITECTURAL PLANS. 14 TEL /DATA TERMINAL BOARD, SEE DETAIL B SHEET E3.O FOR FURTHER REQUIREMENTS. LOCATE LUCENT CABINET IN UPPER CORNER OF PLYWOOD TERMINAL BOARD. VAV -1 I- 0 C -19 \ Q ( TYP) - C - \ I C -19,21 \ 1 15 MAINTAIN CLEARANCE FOR ELECTRICAL EQUIPMENT AS REQUIRED BY N.E.C. TABLE 110- 26(A)(1). 36" FOR 208V EQUIPMENT, AND 42" FOR 480V EQUIPMENT. 16 17 18 20 22 23 24 29 30 r L 1k fi I C -6 IG 0 B-7, B -9 B -5 0 (nP) C- 13,15,17 TS - - -. T -23 ELECTRICAL POWER PLAN 1 /4 " =1' -0" 25 AIR TRANSFER FAN (7--1): 120V, 10, 172W, PROVIDED BY MECHANICAL CONTRACTOR. VERIFY EXACT LOCATION WITH MECHANICAL DRAWINGS. - TT - - - -TT. ' ' C -12 C -12 C -1 TYP EF - AND EF - 2: 120V, 10, 98W, PROVIDED BY HVAC CONTRACTOR. FAN SHALL BE CONTROLLED BY WALL MOUNTED OCCUPANCY SENSOR, PROVIDED BY ELECTRICAL CONTRACTOR. MAKE ALL FINAL CONNECTIONS. VERIFY EXACT LOCATION WITH HVAC CONTRACTOR. LOCATION OF SECURITY KEYPAD. PROVIDE J -BOX AND CONDUIT BACK TO SECURITY PANEL. APPROXIMATE LOCATION OF CEILING MOUNTED SECURITY CAMERA. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH SECURITY INSTALLER. ® DUCT SMOKE DETECTOR PROVIDED BY MECHANICAL CONTRACTOR. ELECTRICAL CONTRACTOR TO MAKE ALL FINAL CONNECTIONS. COORDINATE WITH LANDLORD FOR CONNECTION REQUIREMENTS. PROVIDE SERVICE DOOR BUZZER SYSTEM INCLUDING TRANSFORMER, PUSH - BUTTON AND BUZZER. SEE DETAIL G ON SHEET E3.0 FOR MORE INFORMATION. 21 CEILING MOUNTED DUPLEX RECEPTACLE SHALL BE MOUNTED HORIZONTAL TO STOREFRONT AT 18" OFF OF STOREFRONT GLASS. MOUNT RECEPTACLE AT 86" A.F.F. FOR TELEVISION /DVD PLAYER. MOUNT RECEPTACLE AT 21"± AFF. FROM CENTER OF BOX. RECEPTACLE SHALL BE CENTERED WITHIN COLUMN A BLACK OR WHITE STRIPE ON COLUMN. REFER TO ARCH DETAILS FOR COLOR REQUIRED. PROVIDE POWER AND DATA CONNECTIONS TO RECEIVING DESK. SEE DETAIL F, SHEET E3.0 FOR ADDITIONAL INFORMATION. ELECTRICAL CONTRACTOR TO PROVIDE A CONTACTOR FOR RTU -4, CONTACTOR IS TO BE USED TO INSURE THAT RTU -3 AND RTU -4 WILL NOT SIMULTANEOUSLY OPERATE. PROVIDE JUNCTION BOX FOR MOTOR OPERATED DUCT DAMPERS. COORDINATE EXACT LOCATION WITH HVAC CONTRACTOR. oVAV -1 SENSOR ':lug B -3 IG IG C -2 1 J 1 J. C -4 (M� PROVIDE 120V 20A DEDICATED CIRCUIT FOR SIGNAGE. COORDINATE WITH SIGNAGE SUPPLIER FOR LOCATION AND ROUTING OF CONDUIT. IF SIGN IS IN AN EXTERIOR LOCATION, PROVIDE A WEATHERPROOF JUNCTION BOX. ELECTRICAL CONTRACTOR TO PROVIDE PULL BOX(ES) (SIZED PER NEC 314) FOR ALL POWER CIRCUITS FEEDING THE SALES FLOOR, INCLUDING BUT NOT LIMITED TO FLOOR BOXES, CASHWRAP, WALL DISPLAYS AND STORE FRONT RECEPTACLES. MOUNT BOXES AS HIGH AS POSSIBLE ON BACK OF HOUSE WALL. ALL HOMERUNS BACK TO PANEL ARE TO BE EMT. REFER TO HVAC CONNECTION SCHEDULE, SHEET E5.0, FOR CONDUCTOR, CONDUIT AND OVERCURRENT SIZES. FIELD VERIFY EXACT LOCATION. I uGi C-15 I ADJACENT TENANT 33 34 38 42 43 44 ADJACENT TENANT SHEET E5.0. C -2 C- 7,9,11 (MP) C -12 C -I5 \ 4 1 I I I 36 PROVIDE A 30A NEMA L5 -30R TWIST LOCK RECEPTACLE. C 41 FIRE ALARM CONTRACTOR SHALL PROVIDE SMOKE DETECTOR AND INTERCONNECT DEVICES WITH LANDLORD'S CENTRAL FIRE ALARM SYSTEM. ALL DEVICES SHALL BE WHITE. A-25 1 11 31 PROVIDE A DUPLEX RECEPTACLE FOR OWNER FURNISHED ILLUMINATED MIRROR. RECEPTACLE IS TO BE CONTROLLED VIA THE LIGHTING CONTROL PANEL AND MOUNTED AT 54" A.F.F. 32 CURRENT LIMITING PANEL. SEE "CURRENT LIMITING PANEL DETAIL" APPROXIMATE LOCATION OF TEMPERATURE CONTROL PANEL. PROVIDE (1) RJ -11 AND (1) RJ -45 CONNECTION FOR TEMPERATURE CONTROL. SEE DETAIL B ON SHEET E3.0 FOR MORE INFORMATION. VERIFY EXACT LOCATION WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. PROVIDE A DUPLEX RECEPTACLE, MOUNTED BELOW THE SINK, FOR THE INSTANT WATER HEATER. 35 PROVIDE A SWITCH TO CONTROL UNDER COUNTER LIGHT. SEE SHEET E2.0 FOR MORE INFORMATION. 37 ELECTRICAL CONTRACTOR TO FIELD VERIFY LOCATION OF LANDLORD PROVIDED FUSED DISCONNECT SWITCH BEFORE BIDDING, AND RELOCATE AS REQUIRED. SEE "RISER DIAGRAM ", SHEET E5.0, FOR MORE INFORMATION. ELECTRICAL CONTRACTOR TO PROVIDE A 1" CONDUIT FROM THE MALL COMMINICATION CABLE TRAY, LOCATED IN THE SERVICE CORRIDOR, TO THE NETWORK CABINET. ANY CORRIDOR WALL PENETRATIONS MUST BE FIRE CAULKED AS REQUIRED. VERIFY EXACT LOCATIONS BEFORE BIDDING WORK. SEE "RISER DIAGRAM ", SHEET E5.0, FOR MORE INFORMATION. 39 FIRE ALARM CONTRACTOR SHALL PROVIDE CEILING /WALL MOUNTED AUDIO /VISUAL DEVICES AND INTERCONNECT DEVICES WITH LANDLORD'S CENTRAL FIRE ALARM SYSTEM. DEVICES SHALL BE COMPATIBLE WITH THE LANDLORD'S FIRE ALARM SYSTEM. ALL DEVICES SHALL BE WHITE. 40 LANDLORD TO PROVIDE J -BOX FOR INTERCONNECTION TO MALL FIRE ALARM SYSTEM. VERIFY EXACT LOCATION PRIOR TO ROUGH-IN. A LANDLORD APPROVED FIRE ALARM CONTRACTOR TO MAKE FINAL CONNECTION TO MALL FIRE ALARM SYSTEM. FIRE ALARM CONTRACTOR SHALL PROVIDE AN ANNUNICATOR PANEL AND INTERCONNECT DEVICES WITH LANDLORD'S CENTRAL FIRE ALARM SYSTEM. ALL DEVICES SHALL BE WHITE. PROVIDE A RECESSED FLOOR DUPLEX RECEPTACLE. SEE DETAIL H ON SHEET E3.0 FOR MORE INFORMATION. PROVIDE AN EDWARDS SYSTEMS MODEL# 6538 -G5, OR APPOVED EQUAL, - CALL FOR ASSISTANCE KIT. KIT SHALL INCLUDE AN AUDIBLE HORN /STROBE, POWER TRANSFORMER, AND (2) PULL CORD STATIONS. PULL CORD STATIONS SHALL BE MOUNTED NEAR THE TOLIET, AS INDICATED. SEE DETAIL 1, SHEET E3.O, FOR MORE INFORMATION. F 0 0 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. / C-I-1 - -- r B -20 GENERAL NOTES: C- VAV -4 ENSOR 0 0 TYP �F 1 II II I I I I I I I JII I 1 I II 111 I 11 I II II 11 11 II II II 11 11 11 II B- 31. 11 1 1 11 II 11 11 II 1I II II I Penult Kw A ALL DEVICES SHALL BE NEW UNLESS OTHERWISE NOTED. COORDINATE LOCATION OF ALL OUTLETS AND SWITCHES WITH ARCHITECT'S DRAWINGS B COORDINATE LOCATIONS OF SECURITY DEVICES WITH SECURITY CONTRACTOR. PROVIDE JUNCTION BOXES AND POWER AS REQUIRED. C ALL LINE, LOW VOLTAGE, DATA, COMMUNICATION. SECURITY, SOUND SYSTEM AND ANY OTHER WIRE PULLS SHALL BE IN CONDUIT UNLESS THE LOCAL CODES DO NOT REQUIRE IT. D RECEPTACLES NOTED AS ISOLATED GROUND (IG) SHALL BE ORANGE WITH A WHITE FACE PLATE. E REFER TO DETAIL B ON SHEET E4.0 FOR CONDUIT PENETRATIONS IN RATED WALLS. F ALL FIRE ALARM SYSTEM COMPONENTS PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR AND /OR LANDLORD CONTRACTOR. G ALL CONDUIT HOME RUNS TO THE ELECTRICAL PANELS SHALL BE EMT ONLY. FLEXIBLE ARMORED CABLE SHALL BE ALLOWED IN CONCEALED AREAS FOR BRANCH CIRCUITS WHERE IT IS ALLOWED BY THE NATIONAL FIRE CODE AND THE LANDLORD. I I II II I I II II 11 11 II 11 II I I II 1 lI 1 11�� I 1 13 I - I I 11 II 1 I I I II II X10.9 MALL COMMON 10; Pa.13...bb Ran palm wand lo MOM* Approval r come don not authorize the *Won of cods olradnmres. RoceiPt of approved Rid • and melons iaadmodetlg / X4 Deblc.123 -i City of Tukwila BUILDING DIVISION APPROVED PL ".NG AND `PECIFICAr[OI[' c'u F".7 27 G. ' MODIFIED CR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING ornc :AL, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND I5 "a'.'B.:aCT TO FIELD INSPECTIONS Public works, Bulld!ng Divan PERMIT NUMBER aGICtZs FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. 1 AREA: SHEET TITLE: PROJECT NO. SCALE: DATE: DRAWN BY: REVIEWED BY: SHEET NO. FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 TSAO D= Emp ioda on Em eUN ce M- Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 RMJ Robinson Meier Juilly & Associates www.rmjse.com RMJ Job No.: 07186 PROJECT LOCATION: ELECTRICAL POWER P I1fr 1 2 ?; F L - eI GiN I��j JOB #0712121 C� �'• -� Fi: FILE COPY El .O 41 7 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesign.com 4 Structural Engineers 103 Linden Avenue So. San Francisco, CA 94080 Tel: 650.871.2282 Fax: 650.871.2459 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 98118 5,439 SF 0744.03 10-08-07 FJM DEG � C-9-- --- --- 0 r 9 5 5 4 4 3 3 2 2 1 BUILDING CORRIDOR I 112.5KVA TRANSFORMER 1 1 <VA RM T;AN`. - • -MI= I ^ r III Ili a PANEL �tAVr__ I I NETWORK --1 : -� �C-F -H LC r L B I18 1 8 -40 I .__1 ANEL "C 36 "x12" 36 "x 12' 36 "x 12" B -25/27 ( B -18 C -14,16 C-14 C —L -- -- L__ 4W 4a��i�ri�rr/ Il l PANEL "H" PANEL "B" B -10 B _ 8 B -14 LOW VOLTAGE WRING SPECIFICATIONS (USING CAT -5 WIRING) 1 FROM CASHWRAP TO TEL /DATA TERMINAL BOARD - FOUR CABLES PER REGISTER LOCATION AND TWO SPARE (18 CABLES TOTAL PER TYPICAL 4 REGISTER CASHWRAP AND 28 CABLES TOTAL PER 6 SECTION CASHWRAP (4 SPARE)). A 20 FOOT SERVICE LOOP AT EACH CASHWRAP CONDUIT STUB IS REQUESTED. SEE DETAIL D SHEET E3.0. 2 FROM OFFICE LOCATION TO TEL/DATA TERMINAL BOARD- 4 INDIVIDUAL DROPS BELOW COUNTERTOP. A THREE FOOT SERVICE LOOP AT EACH DATA JACK IN OFFICE AND A 20' SERIVCE LOOP AT THE TEL /DATA TERMINAL BOARD 3 FROM RECEIVING DESK LOCATION TO TEL /DATA TERMINAL BOARD ONE DROP (FOUR CABLES PER DROP). A THREE FOOT SERVICE LOOP AT RECEIVING DESK LOCATION AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 4 FROM TIME AND ATTENDANCE DEVICE (BY OFFICE DOOR) TO TEL/DATA TERMINAL BOARD- ONE DROP (TWO CABLES PER DROP). A THREE FOOT SERVICE LOOP AT TIME AND ATTENDANCE LOCATION AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 5 FROM BURGLAR ALARM BOX TO TEL /DATA TERMINAL BOARD- ONE DROP (ONE CABLE PER DROP). A THREE FOOT SERVICE LOOP AT THE BURGLAR ALARM AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 6 FROM UGHTING CONTROL PANEL TO TEL /DATA TERMINAL BOARD- ONE DROP (ONE CABLE PER DROP). A SIX FOOT SERVICE LOOP AT THE UGHTING CONTROL PANEL LOCATION AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 7 FROM FIRE ALARM BOX TO TEL /DATA TERMINAL BOARD- ONE DROP (ONE CABLE PER DROP). A THREE FOOT SERVICE LOOP AT THE FIRE ALARM LOCATION AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 8 IF CONDUIT TERMINATES AT TELEPHONE TEL /DATA TERMINAL BOARD, A 20 FOOT SERVICE LOOP SHALL BE MEASURED FROM THE END OF THE CONDUIT. 9 IF CONDUIT DOES NOT TERMINATE AT TFI FPHONE TEL /DATA TERMINAL BOARD, CABLE LENGTH SHOULD BE SUFFICIENT TO EXTEND TO THE MIDDLE OF THE BACKBOARD, THEN ADD A 20 FOOT SERVICE LOOP. 10 FROM FRONT DOOR HEADER ABOVE CEILING TO TEL /DATA TERMINAL BOARD- ONE DROP (2 CABLES PER DROP). A 25 FOOT SERVICE LOOP AND TIE OFF TO THE STRUCTURE FOR FUTURE PEOPLE COUNTER, AND A 20' SERIVCE LOOP AT TEL/DATA TERMINAL BOARD IS REQUESTED. 11 FROM SECURTIY (OVER SAFE) TO TEL /DATA TERMINAL BOARD- ONE DROP (4 CABLES PER DROP). A THREE FOOT SERVICE LOOP AT THE SECURITY END AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 12 UGHTING CONTROL PANEL TO HAVE A DEDICATED PHONE UNE FOR REMOTE ACCESS. CONTRACTOR IS TO ROUTE A DEDICATED RJ-11 PHONE CABLE TO LC&D CONTROL PANEL AND MAKE THE TERMINATION. 13 HVAC CONTROL PANEL TO HAVE A DEDICATED PHONE UNE AND DATA LINE FOR REMOTE ACCESS. CONTRACTOR IS TO ROUTE A DEDICATED RJ-11 PHONE CABLE AND A DEDICATED RJ -45 CABLE TO HVAC CONTROL PANEL AND MAKE THE TERMINATION. NOTE: ALL CONDUIT AND WIRE MATERIALS TO BE PROVIDED BY ELECTRICAL CONTRACTOR. 11 12 TYP C -2,4,6 ( LMT PROVIDE DUPLEX RECEPTACLE AND DATA FOR EMPLOYEE TIME CLOCK. VAV -4 CODED NOTES: 0 PROVIDE A DUPLEX RECEPTACLE, MOUNTED HORIZONTALLY AT 4" AF.F. FOR WINDOW DISPLAY. ® PROVIDE (2) 1" CONDUITS FOR SECURITY SYSTEM RACEWAY. STUB ONE END OF CONDUITS 46" A.F.F, AND THE OTHER END ABOVE THE CEILING, IN THE SECURITY OFFICE. PROVIDE PULL BUSHINGS ON ALL CONDUIT ENDS AND PULL STRINGS IN EACH. SEE DETAIL E, SHEET E3.0. FOR MORE INFORMATION. 10 CONTRACTOR IS TO VERIFY THE USE OF A SIX SECTION OR A FOUR SECTION AND SEE "CASH WRAP CONDUIT AND WRING" DETAIL D ON SHEET E3.0 FOR ELECTRICAL REQUIREMENTS AND CIRCUITING IN THIS AREA. PROVIDE A J -BOX FOR SECURITY M0110N DETECTOR. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH SECURITY INSTALLER. LOCATION OF THERMOSTAT OR SENSOR. COORDINATE EXACT LOCATIONS, MOUNTING HEIGHTS AND QUANTITY WITH MECHANICAL AND ARCHITECTURAL PLANS. PROVIDE A JUNCTION BOX, MOUNTED HORIZONTALLY, AND STUB A 3/4" CONDUIT, WITH A PULL STRING, ABOVE THE CEILING FOR EACH DEVICE. PROVIDE A DUPLEX RECEPTACLE MOUNTED BELOW SINK, FOR THE GARBAGE DISPOSAL. RECEPTACLE SHALL BE CONTROLLED BY WALL MOUNTED SWITCH. C- 3,5,23 - -- T■\ C =3 ® PROVIDE CONNECTION TO WALL MOUNTED DISPLAY UNITS. SEE DETAIL C, SHEET E3.O FOR ADDITIONAL CONNECTION REQUIREMENTS. ®3 PROVIDE A JUNCTION BOX FOR FUTURE PEOPLE COUNTER. PROVIDE A TWENTY FOOT SERVICE LOOP OF CABLE AND TIE OFF TO THE STRUCTURE FOR FUTURE USE. ® PROVIDE CONNECTION TO HOT WATER HEATER. COORDINATE LOCATION IN THE FIELD WITH PLUMBING CONTRACTOR. ® CONDUIT SAW -CUT OR CORE DRILLED IN FLOOR. VERIFY REQUIREMENTS FOR SAW - CUTTING OR CORE DRILLING WITH LANDLORD. ROUTE CONDUIT TO NEAREST ACCESSIBLE WALL AND RISE UP TO CEILING. ® MASTER LIGHTING CONTROL PANEL. CONNECT TO CIRCUIT B -15. SEE SCHEDULE ON SHEET E5.0. ® PROVIDE RECESSED DUPLEX FLOOR RECEPTACLE AT GONDOLA. CENTER UNDER 3 SECTION AND THE 1 SECTION GONDOLAS. OFFSET UNDER 2 SECTION GONDOLA. ELECTRICAL CONTRACTOR TO PROVIDE CORD AND PLUG CONNECTION FROM CENTER J -BOX. PROVIDE CONDUIT AND WIRE CONNECTIONS BETWEEN MANUFACTURER SUPPLIED J -BOXES IN GONDOLA SECTIONS. CONTRACTOR IS TO VERIFY THE SLAB TYPE AND REFER TO DETAILS A AND H ON SHEET E3.0. GONDOLAS WITH MAKE -UP MIRROR WILL BE SUPPLIED WITH A WHIP THAT SHALL BE CONNECTED INTO THE JUNCTION BOX OF THE GONDOLA. COORDINATE WITH ARCHITECTURAL PLANS. 14 TEL /DATA TERMINAL BOARD, SEE DETAIL B SHEET E3.O FOR FURTHER REQUIREMENTS. LOCATE LUCENT CABINET IN UPPER CORNER OF PLYWOOD TERMINAL BOARD. VAV -1 I- 0 C -19 \ Q ( TYP) - C - \ I C -19,21 \ 1 15 MAINTAIN CLEARANCE FOR ELECTRICAL EQUIPMENT AS REQUIRED BY N.E.C. TABLE 110- 26(A)(1). 36" FOR 208V EQUIPMENT, AND 42" FOR 480V EQUIPMENT. 16 17 18 20 22 23 24 29 30 r L 1k fi I C -6 IG 0 B-7, B -9 B -5 0 (nP) C- 13,15,17 TS - - -. T -23 ELECTRICAL POWER PLAN 1 /4 " =1' -0" 25 AIR TRANSFER FAN (7--1): 120V, 10, 172W, PROVIDED BY MECHANICAL CONTRACTOR. VERIFY EXACT LOCATION WITH MECHANICAL DRAWINGS. - TT - - - -TT. ' ' C -12 C -12 C -1 TYP EF - AND EF - 2: 120V, 10, 98W, PROVIDED BY HVAC CONTRACTOR. FAN SHALL BE CONTROLLED BY WALL MOUNTED OCCUPANCY SENSOR, PROVIDED BY ELECTRICAL CONTRACTOR. MAKE ALL FINAL CONNECTIONS. VERIFY EXACT LOCATION WITH HVAC CONTRACTOR. LOCATION OF SECURITY KEYPAD. PROVIDE J -BOX AND CONDUIT BACK TO SECURITY PANEL. APPROXIMATE LOCATION OF CEILING MOUNTED SECURITY CAMERA. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH SECURITY INSTALLER. ® DUCT SMOKE DETECTOR PROVIDED BY MECHANICAL CONTRACTOR. ELECTRICAL CONTRACTOR TO MAKE ALL FINAL CONNECTIONS. COORDINATE WITH LANDLORD FOR CONNECTION REQUIREMENTS. PROVIDE SERVICE DOOR BUZZER SYSTEM INCLUDING TRANSFORMER, PUSH - BUTTON AND BUZZER. SEE DETAIL G ON SHEET E3.0 FOR MORE INFORMATION. 21 CEILING MOUNTED DUPLEX RECEPTACLE SHALL BE MOUNTED HORIZONTAL TO STOREFRONT AT 18" OFF OF STOREFRONT GLASS. MOUNT RECEPTACLE AT 86" A.F.F. FOR TELEVISION /DVD PLAYER. MOUNT RECEPTACLE AT 21"± AFF. FROM CENTER OF BOX. RECEPTACLE SHALL BE CENTERED WITHIN COLUMN A BLACK OR WHITE STRIPE ON COLUMN. REFER TO ARCH DETAILS FOR COLOR REQUIRED. PROVIDE POWER AND DATA CONNECTIONS TO RECEIVING DESK. SEE DETAIL F, SHEET E3.0 FOR ADDITIONAL INFORMATION. ELECTRICAL CONTRACTOR TO PROVIDE A CONTACTOR FOR RTU -4, CONTACTOR IS TO BE USED TO INSURE THAT RTU -3 AND RTU -4 WILL NOT SIMULTANEOUSLY OPERATE. PROVIDE JUNCTION BOX FOR MOTOR OPERATED DUCT DAMPERS. COORDINATE EXACT LOCATION WITH HVAC CONTRACTOR. oVAV -1 SENSOR ':lug B -3 IG IG C -2 1 J 1 J. C -4 (M� PROVIDE 120V 20A DEDICATED CIRCUIT FOR SIGNAGE. COORDINATE WITH SIGNAGE SUPPLIER FOR LOCATION AND ROUTING OF CONDUIT. IF SIGN IS IN AN EXTERIOR LOCATION, PROVIDE A WEATHERPROOF JUNCTION BOX. ELECTRICAL CONTRACTOR TO PROVIDE PULL BOX(ES) (SIZED PER NEC 314) FOR ALL POWER CIRCUITS FEEDING THE SALES FLOOR, INCLUDING BUT NOT LIMITED TO FLOOR BOXES, CASHWRAP, WALL DISPLAYS AND STORE FRONT RECEPTACLES. MOUNT BOXES AS HIGH AS POSSIBLE ON BACK OF HOUSE WALL. ALL HOMERUNS BACK TO PANEL ARE TO BE EMT. REFER TO HVAC CONNECTION SCHEDULE, SHEET E5.0, FOR CONDUCTOR, CONDUIT AND OVERCURRENT SIZES. FIELD VERIFY EXACT LOCATION. I uGi C-15 I ADJACENT TENANT 33 34 38 42 43 44 ADJACENT TENANT SHEET E5.0. C -2 C- 7,9,11 (MP) C -12 C -I5 \ 4 1 I I I 36 PROVIDE A 30A NEMA L5 -30R TWIST LOCK RECEPTACLE. C 41 FIRE ALARM CONTRACTOR SHALL PROVIDE SMOKE DETECTOR AND INTERCONNECT DEVICES WITH LANDLORD'S CENTRAL FIRE ALARM SYSTEM. ALL DEVICES SHALL BE WHITE. A-25 1 11 31 PROVIDE A DUPLEX RECEPTACLE FOR OWNER FURNISHED ILLUMINATED MIRROR. RECEPTACLE IS TO BE CONTROLLED VIA THE LIGHTING CONTROL PANEL AND MOUNTED AT 54" A.F.F. 32 CURRENT LIMITING PANEL. SEE "CURRENT LIMITING PANEL DETAIL" APPROXIMATE LOCATION OF TEMPERATURE CONTROL PANEL. PROVIDE (1) RJ -11 AND (1) RJ -45 CONNECTION FOR TEMPERATURE CONTROL. SEE DETAIL B ON SHEET E3.0 FOR MORE INFORMATION. VERIFY EXACT LOCATION WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. PROVIDE A DUPLEX RECEPTACLE, MOUNTED BELOW THE SINK, FOR THE INSTANT WATER HEATER. 35 PROVIDE A SWITCH TO CONTROL UNDER COUNTER LIGHT. SEE SHEET E2.0 FOR MORE INFORMATION. 37 ELECTRICAL CONTRACTOR TO FIELD VERIFY LOCATION OF LANDLORD PROVIDED FUSED DISCONNECT SWITCH BEFORE BIDDING, AND RELOCATE AS REQUIRED. SEE "RISER DIAGRAM ", SHEET E5.0, FOR MORE INFORMATION. ELECTRICAL CONTRACTOR TO PROVIDE A 1" CONDUIT FROM THE MALL COMMINICATION CABLE TRAY, LOCATED IN THE SERVICE CORRIDOR, TO THE NETWORK CABINET. ANY CORRIDOR WALL PENETRATIONS MUST BE FIRE CAULKED AS REQUIRED. VERIFY EXACT LOCATIONS BEFORE BIDDING WORK. SEE "RISER DIAGRAM ", SHEET E5.0, FOR MORE INFORMATION. 39 FIRE ALARM CONTRACTOR SHALL PROVIDE CEILING /WALL MOUNTED AUDIO /VISUAL DEVICES AND INTERCONNECT DEVICES WITH LANDLORD'S CENTRAL FIRE ALARM SYSTEM. DEVICES SHALL BE COMPATIBLE WITH THE LANDLORD'S FIRE ALARM SYSTEM. ALL DEVICES SHALL BE WHITE. 40 LANDLORD TO PROVIDE J -BOX FOR INTERCONNECTION TO MALL FIRE ALARM SYSTEM. VERIFY EXACT LOCATION PRIOR TO ROUGH-IN. A LANDLORD APPROVED FIRE ALARM CONTRACTOR TO MAKE FINAL CONNECTION TO MALL FIRE ALARM SYSTEM. FIRE ALARM CONTRACTOR SHALL PROVIDE AN ANNUNICATOR PANEL AND INTERCONNECT DEVICES WITH LANDLORD'S CENTRAL FIRE ALARM SYSTEM. ALL DEVICES SHALL BE WHITE. PROVIDE A RECESSED FLOOR DUPLEX RECEPTACLE. SEE DETAIL H ON SHEET E3.0 FOR MORE INFORMATION. PROVIDE AN EDWARDS SYSTEMS MODEL# 6538 -G5, OR APPOVED EQUAL, - CALL FOR ASSISTANCE KIT. KIT SHALL INCLUDE AN AUDIBLE HORN /STROBE, POWER TRANSFORMER, AND (2) PULL CORD STATIONS. PULL CORD STATIONS SHALL BE MOUNTED NEAR THE TOLIET, AS INDICATED. SEE DETAIL 1, SHEET E3.O, FOR MORE INFORMATION. F 0 0 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. / C-I-1 - -- r B -20 GENERAL NOTES: C- VAV -4 ENSOR 0 0 TYP �F 1 II II I I I I I I I JII I 1 I II 111 I 11 I II II 11 11 II II II 11 11 11 II B- 31. 11 1 1 11 II 11 11 II 1I II II I Penult Kw A ALL DEVICES SHALL BE NEW UNLESS OTHERWISE NOTED. COORDINATE LOCATION OF ALL OUTLETS AND SWITCHES WITH ARCHITECT'S DRAWINGS B COORDINATE LOCATIONS OF SECURITY DEVICES WITH SECURITY CONTRACTOR. PROVIDE JUNCTION BOXES AND POWER AS REQUIRED. C ALL LINE, LOW VOLTAGE, DATA, COMMUNICATION. SECURITY, SOUND SYSTEM AND ANY OTHER WIRE PULLS SHALL BE IN CONDUIT UNLESS THE LOCAL CODES DO NOT REQUIRE IT. D RECEPTACLES NOTED AS ISOLATED GROUND (IG) SHALL BE ORANGE WITH A WHITE FACE PLATE. E REFER TO DETAIL B ON SHEET E4.0 FOR CONDUIT PENETRATIONS IN RATED WALLS. F ALL FIRE ALARM SYSTEM COMPONENTS PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR AND /OR LANDLORD CONTRACTOR. G ALL CONDUIT HOME RUNS TO THE ELECTRICAL PANELS SHALL BE EMT ONLY. FLEXIBLE ARMORED CABLE SHALL BE ALLOWED IN CONCEALED AREAS FOR BRANCH CIRCUITS WHERE IT IS ALLOWED BY THE NATIONAL FIRE CODE AND THE LANDLORD. I I II II I I II II 11 11 II 11 II I I II 1 lI 1 11�� I 1 13 I - I I 11 II 1 I I I II II X10.9 MALL COMMON 10; Pa.13...bb Ran palm wand lo MOM* Approval r come don not authorize the *Won of cods olradnmres. RoceiPt of approved Rid • and melons iaadmodetlg / X4 Deblc.123 -i City of Tukwila BUILDING DIVISION APPROVED PL ".NG AND `PECIFICAr[OI[' c'u F".7 27 G. ' MODIFIED CR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING ornc :AL, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND I5 "a'.'B.:aCT TO FIELD INSPECTIONS Public works, Bulld!ng Divan PERMIT NUMBER aGICtZs FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. 1 AREA: SHEET TITLE: PROJECT NO. SCALE: DATE: DRAWN BY: REVIEWED BY: SHEET NO. FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 TSAO D= Emp ioda on Em eUN ce M- Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 RMJ Robinson Meier Juilly & Associates www.rmjse.com RMJ Job No.: 07186 PROJECT LOCATION: ELECTRICAL POWER P I1fr 1 2 ?; F L - eI GiN I��j JOB #0712121 C� �'• -� Fi: FILE COPY El .O 41 7 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesign.com 4 Structural Engineers 103 Linden Avenue So. San Francisco, CA 94080 Tel: 650.871.2282 Fax: 650.871.2459 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 98118 5,439 SF 0744.03 10-08-07 FJM DEG 10-08 -07 ISSUE FOR PERMIT JAH WPK 07 -27 -07 CLIENT /PRELIM. LL REVIEW JAH WPK A DATE ISSUE DESCRIPTION BY CHECK 5 5 4 4 3 3 2 2 1 BUILDING CORRIDOR I 112.5KVA TRANSFORMER 1 1 <VA RM T;AN`. - • -MI= I ^ r III Ili a PANEL �tAVr__ I I NETWORK --1 : -� �C-F -H LC r L B I18 1 8 -40 I .__1 ANEL "C 36 "x12" 36 "x 12' 36 "x 12" B -25/27 ( B -18 C -14,16 C-14 C —L -- -- L__ 4W 4a��i�ri�rr/ Il l PANEL "H" PANEL "B" B -10 B _ 8 B -14 LOW VOLTAGE WRING SPECIFICATIONS (USING CAT -5 WIRING) 1 FROM CASHWRAP TO TEL /DATA TERMINAL BOARD - FOUR CABLES PER REGISTER LOCATION AND TWO SPARE (18 CABLES TOTAL PER TYPICAL 4 REGISTER CASHWRAP AND 28 CABLES TOTAL PER 6 SECTION CASHWRAP (4 SPARE)). A 20 FOOT SERVICE LOOP AT EACH CASHWRAP CONDUIT STUB IS REQUESTED. SEE DETAIL D SHEET E3.0. 2 FROM OFFICE LOCATION TO TEL/DATA TERMINAL BOARD- 4 INDIVIDUAL DROPS BELOW COUNTERTOP. A THREE FOOT SERVICE LOOP AT EACH DATA JACK IN OFFICE AND A 20' SERIVCE LOOP AT THE TEL /DATA TERMINAL BOARD 3 FROM RECEIVING DESK LOCATION TO TEL /DATA TERMINAL BOARD ONE DROP (FOUR CABLES PER DROP). A THREE FOOT SERVICE LOOP AT RECEIVING DESK LOCATION AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 4 FROM TIME AND ATTENDANCE DEVICE (BY OFFICE DOOR) TO TEL/DATA TERMINAL BOARD- ONE DROP (TWO CABLES PER DROP). A THREE FOOT SERVICE LOOP AT TIME AND ATTENDANCE LOCATION AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 5 FROM BURGLAR ALARM BOX TO TEL /DATA TERMINAL BOARD- ONE DROP (ONE CABLE PER DROP). A THREE FOOT SERVICE LOOP AT THE BURGLAR ALARM AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 6 FROM UGHTING CONTROL PANEL TO TEL /DATA TERMINAL BOARD- ONE DROP (ONE CABLE PER DROP). A SIX FOOT SERVICE LOOP AT THE UGHTING CONTROL PANEL LOCATION AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 7 FROM FIRE ALARM BOX TO TEL /DATA TERMINAL BOARD- ONE DROP (ONE CABLE PER DROP). A THREE FOOT SERVICE LOOP AT THE FIRE ALARM LOCATION AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 8 IF CONDUIT TERMINATES AT TELEPHONE TEL /DATA TERMINAL BOARD, A 20 FOOT SERVICE LOOP SHALL BE MEASURED FROM THE END OF THE CONDUIT. 9 IF CONDUIT DOES NOT TERMINATE AT TFI FPHONE TEL /DATA TERMINAL BOARD, CABLE LENGTH SHOULD BE SUFFICIENT TO EXTEND TO THE MIDDLE OF THE BACKBOARD, THEN ADD A 20 FOOT SERVICE LOOP. 10 FROM FRONT DOOR HEADER ABOVE CEILING TO TEL /DATA TERMINAL BOARD- ONE DROP (2 CABLES PER DROP). A 25 FOOT SERVICE LOOP AND TIE OFF TO THE STRUCTURE FOR FUTURE PEOPLE COUNTER, AND A 20' SERIVCE LOOP AT TEL/DATA TERMINAL BOARD IS REQUESTED. 11 FROM SECURTIY (OVER SAFE) TO TEL /DATA TERMINAL BOARD- ONE DROP (4 CABLES PER DROP). A THREE FOOT SERVICE LOOP AT THE SECURITY END AND A 20' SERIVCE LOOP AT TEL /DATA TERMINAL BOARD IS REQUESTED. 12 UGHTING CONTROL PANEL TO HAVE A DEDICATED PHONE UNE FOR REMOTE ACCESS. CONTRACTOR IS TO ROUTE A DEDICATED RJ-11 PHONE CABLE TO LC&D CONTROL PANEL AND MAKE THE TERMINATION. 13 HVAC CONTROL PANEL TO HAVE A DEDICATED PHONE UNE AND DATA LINE FOR REMOTE ACCESS. CONTRACTOR IS TO ROUTE A DEDICATED RJ-11 PHONE CABLE AND A DEDICATED RJ -45 CABLE TO HVAC CONTROL PANEL AND MAKE THE TERMINATION. NOTE: ALL CONDUIT AND WIRE MATERIALS TO BE PROVIDED BY ELECTRICAL CONTRACTOR. 11 12 TYP C -2,4,6 ( LMT PROVIDE DUPLEX RECEPTACLE AND DATA FOR EMPLOYEE TIME CLOCK. VAV -4 CODED NOTES: 0 PROVIDE A DUPLEX RECEPTACLE, MOUNTED HORIZONTALLY AT 4" AF.F. FOR WINDOW DISPLAY. ® PROVIDE (2) 1" CONDUITS FOR SECURITY SYSTEM RACEWAY. STUB ONE END OF CONDUITS 46" A.F.F, AND THE OTHER END ABOVE THE CEILING, IN THE SECURITY OFFICE. PROVIDE PULL BUSHINGS ON ALL CONDUIT ENDS AND PULL STRINGS IN EACH. SEE DETAIL E, SHEET E3.0. FOR MORE INFORMATION. 10 CONTRACTOR IS TO VERIFY THE USE OF A SIX SECTION OR A FOUR SECTION AND SEE "CASH WRAP CONDUIT AND WRING" DETAIL D ON SHEET E3.0 FOR ELECTRICAL REQUIREMENTS AND CIRCUITING IN THIS AREA. PROVIDE A J -BOX FOR SECURITY M0110N DETECTOR. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH SECURITY INSTALLER. LOCATION OF THERMOSTAT OR SENSOR. COORDINATE EXACT LOCATIONS, MOUNTING HEIGHTS AND QUANTITY WITH MECHANICAL AND ARCHITECTURAL PLANS. PROVIDE A JUNCTION BOX, MOUNTED HORIZONTALLY, AND STUB A 3/4" CONDUIT, WITH A PULL STRING, ABOVE THE CEILING FOR EACH DEVICE. PROVIDE A DUPLEX RECEPTACLE MOUNTED BELOW SINK, FOR THE GARBAGE DISPOSAL. RECEPTACLE SHALL BE CONTROLLED BY WALL MOUNTED SWITCH. C- 3,5,23 - -- T■\ C =3 ® PROVIDE CONNECTION TO WALL MOUNTED DISPLAY UNITS. SEE DETAIL C, SHEET E3.O FOR ADDITIONAL CONNECTION REQUIREMENTS. ®3 PROVIDE A JUNCTION BOX FOR FUTURE PEOPLE COUNTER. PROVIDE A TWENTY FOOT SERVICE LOOP OF CABLE AND TIE OFF TO THE STRUCTURE FOR FUTURE USE. ® PROVIDE CONNECTION TO HOT WATER HEATER. COORDINATE LOCATION IN THE FIELD WITH PLUMBING CONTRACTOR. ® CONDUIT SAW -CUT OR CORE DRILLED IN FLOOR. VERIFY REQUIREMENTS FOR SAW - CUTTING OR CORE DRILLING WITH LANDLORD. ROUTE CONDUIT TO NEAREST ACCESSIBLE WALL AND RISE UP TO CEILING. ® MASTER LIGHTING CONTROL PANEL. CONNECT TO CIRCUIT B -15. SEE SCHEDULE ON SHEET E5.0. ® PROVIDE RECESSED DUPLEX FLOOR RECEPTACLE AT GONDOLA. CENTER UNDER 3 SECTION AND THE 1 SECTION GONDOLAS. OFFSET UNDER 2 SECTION GONDOLA. ELECTRICAL CONTRACTOR TO PROVIDE CORD AND PLUG CONNECTION FROM CENTER J -BOX. PROVIDE CONDUIT AND WIRE CONNECTIONS BETWEEN MANUFACTURER SUPPLIED J -BOXES IN GONDOLA SECTIONS. CONTRACTOR IS TO VERIFY THE SLAB TYPE AND REFER TO DETAILS A AND H ON SHEET E3.0. GONDOLAS WITH MAKE -UP MIRROR WILL BE SUPPLIED WITH A WHIP THAT SHALL BE CONNECTED INTO THE JUNCTION BOX OF THE GONDOLA. COORDINATE WITH ARCHITECTURAL PLANS. 14 TEL /DATA TERMINAL BOARD, SEE DETAIL B SHEET E3.O FOR FURTHER REQUIREMENTS. LOCATE LUCENT CABINET IN UPPER CORNER OF PLYWOOD TERMINAL BOARD. VAV -1 I- 0 C -19 \ Q ( TYP) - C - \ I C -19,21 \ 1 15 MAINTAIN CLEARANCE FOR ELECTRICAL EQUIPMENT AS REQUIRED BY N.E.C. TABLE 110- 26(A)(1). 36" FOR 208V EQUIPMENT, AND 42" FOR 480V EQUIPMENT. 16 17 18 20 22 23 24 29 30 r L 1k fi I C -6 IG 0 B-7, B -9 B -5 0 (nP) C- 13,15,17 TS - - -. T -23 ELECTRICAL POWER PLAN 1 /4 " =1' -0" 25 AIR TRANSFER FAN (7--1): 120V, 10, 172W, PROVIDED BY MECHANICAL CONTRACTOR. VERIFY EXACT LOCATION WITH MECHANICAL DRAWINGS. - TT - - - -TT. ' ' C -12 C -12 C -1 TYP EF - AND EF - 2: 120V, 10, 98W, PROVIDED BY HVAC CONTRACTOR. FAN SHALL BE CONTROLLED BY WALL MOUNTED OCCUPANCY SENSOR, PROVIDED BY ELECTRICAL CONTRACTOR. MAKE ALL FINAL CONNECTIONS. VERIFY EXACT LOCATION WITH HVAC CONTRACTOR. LOCATION OF SECURITY KEYPAD. PROVIDE J -BOX AND CONDUIT BACK TO SECURITY PANEL. APPROXIMATE LOCATION OF CEILING MOUNTED SECURITY CAMERA. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH SECURITY INSTALLER. ® DUCT SMOKE DETECTOR PROVIDED BY MECHANICAL CONTRACTOR. ELECTRICAL CONTRACTOR TO MAKE ALL FINAL CONNECTIONS. COORDINATE WITH LANDLORD FOR CONNECTION REQUIREMENTS. PROVIDE SERVICE DOOR BUZZER SYSTEM INCLUDING TRANSFORMER, PUSH - BUTTON AND BUZZER. SEE DETAIL G ON SHEET E3.0 FOR MORE INFORMATION. 21 CEILING MOUNTED DUPLEX RECEPTACLE SHALL BE MOUNTED HORIZONTAL TO STOREFRONT AT 18" OFF OF STOREFRONT GLASS. MOUNT RECEPTACLE AT 86" A.F.F. FOR TELEVISION /DVD PLAYER. MOUNT RECEPTACLE AT 21"± AFF. FROM CENTER OF BOX. RECEPTACLE SHALL BE CENTERED WITHIN COLUMN A BLACK OR WHITE STRIPE ON COLUMN. REFER TO ARCH DETAILS FOR COLOR REQUIRED. PROVIDE POWER AND DATA CONNECTIONS TO RECEIVING DESK. SEE DETAIL F, SHEET E3.0 FOR ADDITIONAL INFORMATION. ELECTRICAL CONTRACTOR TO PROVIDE A CONTACTOR FOR RTU -4, CONTACTOR IS TO BE USED TO INSURE THAT RTU -3 AND RTU -4 WILL NOT SIMULTANEOUSLY OPERATE. PROVIDE JUNCTION BOX FOR MOTOR OPERATED DUCT DAMPERS. COORDINATE EXACT LOCATION WITH HVAC CONTRACTOR. oVAV -1 SENSOR ':lug B -3 IG IG C -2 1 J 1 J. C -4 (M� PROVIDE 120V 20A DEDICATED CIRCUIT FOR SIGNAGE. COORDINATE WITH SIGNAGE SUPPLIER FOR LOCATION AND ROUTING OF CONDUIT. IF SIGN IS IN AN EXTERIOR LOCATION, PROVIDE A WEATHERPROOF JUNCTION BOX. ELECTRICAL CONTRACTOR TO PROVIDE PULL BOX(ES) (SIZED PER NEC 314) FOR ALL POWER CIRCUITS FEEDING THE SALES FLOOR, INCLUDING BUT NOT LIMITED TO FLOOR BOXES, CASHWRAP, WALL DISPLAYS AND STORE FRONT RECEPTACLES. MOUNT BOXES AS HIGH AS POSSIBLE ON BACK OF HOUSE WALL. ALL HOMERUNS BACK TO PANEL ARE TO BE EMT. REFER TO HVAC CONNECTION SCHEDULE, SHEET E5.0, FOR CONDUCTOR, CONDUIT AND OVERCURRENT SIZES. FIELD VERIFY EXACT LOCATION. I uGi C-15 I ADJACENT TENANT 33 34 38 42 43 44 ADJACENT TENANT SHEET E5.0. C -2 C- 7,9,11 (MP) C -12 C -I5 \ 4 1 I I I 36 PROVIDE A 30A NEMA L5 -30R TWIST LOCK RECEPTACLE. C 41 FIRE ALARM CONTRACTOR SHALL PROVIDE SMOKE DETECTOR AND INTERCONNECT DEVICES WITH LANDLORD'S CENTRAL FIRE ALARM SYSTEM. ALL DEVICES SHALL BE WHITE. A-25 1 11 31 PROVIDE A DUPLEX RECEPTACLE FOR OWNER FURNISHED ILLUMINATED MIRROR. RECEPTACLE IS TO BE CONTROLLED VIA THE LIGHTING CONTROL PANEL AND MOUNTED AT 54" A.F.F. 32 CURRENT LIMITING PANEL. SEE "CURRENT LIMITING PANEL DETAIL" APPROXIMATE LOCATION OF TEMPERATURE CONTROL PANEL. PROVIDE (1) RJ -11 AND (1) RJ -45 CONNECTION FOR TEMPERATURE CONTROL. SEE DETAIL B ON SHEET E3.0 FOR MORE INFORMATION. VERIFY EXACT LOCATION WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. PROVIDE A DUPLEX RECEPTACLE, MOUNTED BELOW THE SINK, FOR THE INSTANT WATER HEATER. 35 PROVIDE A SWITCH TO CONTROL UNDER COUNTER LIGHT. SEE SHEET E2.0 FOR MORE INFORMATION. 37 ELECTRICAL CONTRACTOR TO FIELD VERIFY LOCATION OF LANDLORD PROVIDED FUSED DISCONNECT SWITCH BEFORE BIDDING, AND RELOCATE AS REQUIRED. SEE "RISER DIAGRAM ", SHEET E5.0, FOR MORE INFORMATION. ELECTRICAL CONTRACTOR TO PROVIDE A 1" CONDUIT FROM THE MALL COMMINICATION CABLE TRAY, LOCATED IN THE SERVICE CORRIDOR, TO THE NETWORK CABINET. ANY CORRIDOR WALL PENETRATIONS MUST BE FIRE CAULKED AS REQUIRED. VERIFY EXACT LOCATIONS BEFORE BIDDING WORK. SEE "RISER DIAGRAM ", SHEET E5.0, FOR MORE INFORMATION. 39 FIRE ALARM CONTRACTOR SHALL PROVIDE CEILING /WALL MOUNTED AUDIO /VISUAL DEVICES AND INTERCONNECT DEVICES WITH LANDLORD'S CENTRAL FIRE ALARM SYSTEM. DEVICES SHALL BE COMPATIBLE WITH THE LANDLORD'S FIRE ALARM SYSTEM. ALL DEVICES SHALL BE WHITE. 40 LANDLORD TO PROVIDE J -BOX FOR INTERCONNECTION TO MALL FIRE ALARM SYSTEM. VERIFY EXACT LOCATION PRIOR TO ROUGH-IN. A LANDLORD APPROVED FIRE ALARM CONTRACTOR TO MAKE FINAL CONNECTION TO MALL FIRE ALARM SYSTEM. FIRE ALARM CONTRACTOR SHALL PROVIDE AN ANNUNICATOR PANEL AND INTERCONNECT DEVICES WITH LANDLORD'S CENTRAL FIRE ALARM SYSTEM. ALL DEVICES SHALL BE WHITE. PROVIDE A RECESSED FLOOR DUPLEX RECEPTACLE. SEE DETAIL H ON SHEET E3.0 FOR MORE INFORMATION. PROVIDE AN EDWARDS SYSTEMS MODEL# 6538 -G5, OR APPOVED EQUAL, - CALL FOR ASSISTANCE KIT. KIT SHALL INCLUDE AN AUDIBLE HORN /STROBE, POWER TRANSFORMER, AND (2) PULL CORD STATIONS. PULL CORD STATIONS SHALL BE MOUNTED NEAR THE TOLIET, AS INDICATED. SEE DETAIL 1, SHEET E3.O, FOR MORE INFORMATION. F 0 0 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. / C-I-1 - -- r B -20 GENERAL NOTES: C- VAV -4 ENSOR 0 0 TYP �F 1 II II I I I I I I I JII I 1 I II 111 I 11 I II II 11 11 II II II 11 11 11 II B- 31. 11 1 1 11 II 11 11 II 1I II II I Penult Kw A ALL DEVICES SHALL BE NEW UNLESS OTHERWISE NOTED. COORDINATE LOCATION OF ALL OUTLETS AND SWITCHES WITH ARCHITECT'S DRAWINGS B COORDINATE LOCATIONS OF SECURITY DEVICES WITH SECURITY CONTRACTOR. PROVIDE JUNCTION BOXES AND POWER AS REQUIRED. C ALL LINE, LOW VOLTAGE, DATA, COMMUNICATION. SECURITY, SOUND SYSTEM AND ANY OTHER WIRE PULLS SHALL BE IN CONDUIT UNLESS THE LOCAL CODES DO NOT REQUIRE IT. D RECEPTACLES NOTED AS ISOLATED GROUND (IG) SHALL BE ORANGE WITH A WHITE FACE PLATE. E REFER TO DETAIL B ON SHEET E4.0 FOR CONDUIT PENETRATIONS IN RATED WALLS. F ALL FIRE ALARM SYSTEM COMPONENTS PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR AND /OR LANDLORD CONTRACTOR. G ALL CONDUIT HOME RUNS TO THE ELECTRICAL PANELS SHALL BE EMT ONLY. FLEXIBLE ARMORED CABLE SHALL BE ALLOWED IN CONCEALED AREAS FOR BRANCH CIRCUITS WHERE IT IS ALLOWED BY THE NATIONAL FIRE CODE AND THE LANDLORD. I I II II I I II II 11 11 II 11 II I I II 1 lI 1 11�� I 1 13 I - I I 11 II 1 I I I II II X10.9 MALL COMMON 10; Pa.13...bb Ran palm wand lo MOM* Approval r come don not authorize the *Won of cods olradnmres. RoceiPt of approved Rid • and melons iaadmodetlg / X4 Deblc.123 -i City of Tukwila BUILDING DIVISION APPROVED PL ".NG AND `PECIFICAr[OI[' c'u F".7 27 G. ' MODIFIED CR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING ornc :AL, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND I5 "a'.'B.:aCT TO FIELD INSPECTIONS Public works, Bulld!ng Divan PERMIT NUMBER aGICtZs FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. 1 AREA: SHEET TITLE: PROJECT NO. SCALE: DATE: DRAWN BY: REVIEWED BY: SHEET NO. FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 TSAO D= Emp ioda on Em eUN ce M- Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 RMJ Robinson Meier Juilly & Associates www.rmjse.com RMJ Job No.: 07186 PROJECT LOCATION: ELECTRICAL POWER P I1fr 1 2 ?; F L - eI GiN I��j JOB #0712121 C� �'• -� Fi: FILE COPY El .O 41 7 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesign.com 4 Structural Engineers 103 Linden Avenue So. San Francisco, CA 94080 Tel: 650.871.2282 Fax: 650.871.2459 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 98118 5,439 SF 0744.03 10-08-07 FJM DEG 5 5 4 4 3 3 2 2 1 112.5KVA TRANSFORMER BUILDING CORRIDOR MAIN DISCONNECT PANEL "H" PANEL "B" FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. C-20 ELECTRICAL LIGHTING PLAN 1 /4 "= 1'--0" ADJACENT TENANT FU/NL-EM L L FU /NL -EM CURRENT LIMITING PANEL r l FU /NL -EM FU/NL-EM FT /NL -EM FA -1 FA- FA-1 FA -1 FA -1 FA -1 FA -1 FA -1 FA -1 FA -1 FA -1 FA -1 FA -1 FA -1 -S DP) F +/ NL FJ FA -1 L FA -1 FA -1 FA -1 FA -1 FA -1 — FJ — FJ �► �TYR FJ F �NL -- - FJ/ — - - - J . '� ... • ..._ i ce ' . — _. 0____ urr. • ■� � s • o � a ® o FJ _ — � � A -7 FA -1 FA -1 FA -1 FA -1 FA -1 FA -1 FA--1 FA -1 FA -1 FA -1 ADJACENT TENANT 0 0 0 0 0 0 0 0 0 0 10 11 12 CODED NOTES: PROVIDE J -BOX AND CONDUIT TO LIGHTING CONTROL PANEL FOR EMPLOYEE ON /OFF LOW VOLTAGE KEYPAD. CONTRACTOR MUST INSTALL MANUFACTURE SUPPLIED HINGED COVER PLATE. REFER TO "LV RELAY PANEL DIAGRAM ", SHEET E5.0, FOR MORE INFORMATION. PROVIDE A CAT5 CABLE TO THE LC &D CONTROL PANEL, AND MAKE ALL FINAL CONNECTIONS, FOR CONTROL OF THE RELAYS. MOUNT EXIT SIGN AT 11' -0" ABOVE THE FINISHED FLOOR OVER THE BLIND DOOR. CONNECT EXIT SIGN TO LOCAL LIGHTING CIRCUIT, AHEAD OF ANY SWITCHING. NON -SALES NIGHT /EMERGENCY LIGHT FIXTURE. THIS FIXTURE SHALL BE CONNECTED AHEAD OF ANY SWITCHING AND HAVE A BATTERY BACKUP TO PROVIDE AT LEAST 90 MIN. OF EMERGENCY ILLUMINATION AND MAINTAIN NOT LESS THAN 60% OF THE INITIAL EMERGENCY ILLUMINATION PER NEC 700.12 (F). PROVIDE 120V 20A SWITCH FOR CONTROL OF UNDER COUNTER LIGHT FIXTURE. FEED SWITCH FROM LOAD SIDE OF GFCI RECEPTACLE. REFER TO SHEET E1.0 FOR MORE INFORMATION. PROVIDE A THREE -LAMP DUAL BALLAST RECESSED FIXTURE. ONE BALLAST SHALL CONTROL THE CENTER LAMP WHICH WILL SERVE AS AN EMERGENCY LIGHT. THIS LAMP SHALL BE CONTROLLED BY THE WALL MOUNTED OCCUPANCY SENSOR UNDER NORMAL POWER, AND TURN ON, VIA A BATTERY BACK -UP WHEN NORMAL POWER IS LOSSED, REGARDLESS OF SWITCH POSITION. THE OTHER 2 LAMPS ARE TO BE WIRED TO THE 2 CIRCUIT WALL MOTION SENSOR SWITCH ALONG WITH EXHAUST FAN. CONTRACTOR TO PROVIDE PULL BOX(ES) (SIZED PER NEC 314) FOR ALL LIGHTING CIRCUITS FEEDING THE SALES FLOOR, INCLUDING BUT NOT LIMITED TO TRACK AND COVE LIGHTING. MOUNT BOXES AS HIGH AS POSSIBLE ON BACK OF HOUSE WALL. ALL HOMERUNS FROM BACK TO PANEL ARE TO BE EMT. PROVIDE J -BOX AND CONDUIT TO LIGHTING CONTROL PANEL FOR MASTER CONTROL ON /OFF LOW VOLTAGE KEYPAD. LOW VOLTAGE BUTTONS ARE TO BE IN 2 SEPARATE BOXES, ONE FOR EACH SWITCH. CONTRACTOR MUST INSTALL MANUFACTURE SUPPLIED HINGED COVER PLATE. SEE DETAIL #2 SHEET E -2. CONTRACTOR IS TO PROVIDE A CAT -5 CABLE BACK TO THE LC &D CONTROL PANEL, AND MAKE TERMINATION AT BOTH, FOR CONTROL OF THE RELAYS. CONNECT TRACK THUR CURRENT LIMITING PANEL. REFER TO "CURRENT LIMITING PANEL DIAGRAM ", SHEET E5.0, FOR MORE INFORMATION. PROVIDE J - BOX AND A 120V, 20A DEDICATED CIRCUIT FOR REAR SKIN CARE WALL LIGHTING. COORDINATE ALL RELATED WORK WITH SEPHORA CONTACT IN FIELD. CONNECT EXIT, EMERGENCY, NIGHT LIGHT FIXTURES IN SALES AREA TO CIRCUIT A-23. PROVIDE SCREW TYPE LO'S AT THE BREAKER. COVE LIGHTS SHOWN ON PLAN ARE AN APPROXIMATION OF QUANTITY NEEDED. LIGHTING SUPPLIER SHALL PROVIDE SUFFICIENT FIXTURES TO CREATE A CONTINUOUS RUN. 1 1 GENERAL NOTES: 1 A ALL DEVICES TO BE NEW UNLESS OTHERWISE NOTED. COORDINATE LOCATION OF ALL FIXTURES AND SWITCHES WITH ARCHITECT'S DRAWINGS. B THE LIGHTING FIXTURE SUPPLIER SHALL PROVIDE FROM THE FIXTURE MANUFACTURER A COMPLETE SET OF INSTRUCTIONS FOR OPERATION AND MAINTENANCE OF THE FIXTURES. AT EACH BATTERY UNIT A LOG OF THE ORIGINAL INSTALLATION DATE AND SUBSEQUENT MAINTENANCE DATES SHALL BE POSTED. C SEE SHEET E4.0 FOR LIGHT FIXTURE SCHEDULE. D ALL NORMAL LIGHTING CIRCUITS SHALL BE CONTROLLED THROUGH LOW VOLTAGE RELAY PANELS. INSTALL LV LIGHTING CONTROL SYSTEM. SEE SHEET E5.0 FOR MORE INFORMATION. E REFER TO DETAIL B ON SHEET E4.0 FOR CONDUIT PENETRATIONS IN RATED WALLS. F FOR EMERGENCY AND EXIT LIGHTING, FEED FIXTURE FROM ADJACENT LIGHTING CIRCUIT IN THE AREA AHEAD OF THE LIGHTING CONTROL PANEL. G ALL CONDUIT HOMERUNS TO THE ELECTRICAL PANELS SHALL BE EMT ONLY. FLEXIBLE ARMORED CABLE WILL ONLY BE ALLOWED IN CONCEALED AREAS FOR BRANCH CIRCUITS WHERE IT IS ALLOWED BY CODE AND THE LANDLORD. H REFER TO DETAIL A ON SHEET E4.0 FOR CEILING EQUIPMENT /FIXTURE MOUNTING. J 1 1 1 1 1 1 11 I I I1 I 1 1 1 1 1 I1 1 1 1 1 11 1 1 1 11 II 11 1 11 1 11 I I i 1 1 1 1 11 11 11 II 1I 11 1 1 I1 II 11 1I I1 1 1 1 11 1 MALL COMMON 10 REVVED FOR CODE A 70P COMPLIANCE NEC E NF NOV 2 6 2007 City Of Tukwila BUILDING D 510N J 1 FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 TSAO 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 RMJ Robinson Meier Juilly & Associates www.rulse.corn RMJ Job No.: 07186 PROJECT LOCATION: AREA: SHEET TITLE: DRAWN BY: REVIEWED BY: SHEET NO. 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f Www.tsaodosign.com Emphasis on pence M- Retail Engineering, Inc. JOB #0712121 Structural Engineers 103 Linden Avenue So. San Francisco, CA 94080 Tel: 650.871.2282 Fax: 650.871.2459 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 98118 ELECTRICAL LIGHTI\ CL.(\I I Sri G P E2.0 5,439 SF LA PROJECT NO. 0744.03 SCALE: FF.HC:=s4la) 1/4" = ' — 0" DATE: C CT 12 07 10 -08 -07 FJM DEG D C B A 10 -08-07 ISSUE FOR PERMIT JAH WPK 07 -27 -07 CLIENT /PRELIM. LL REVIEW JAH WPK L DATE ISSUE DESCRIPTION BY CHECK 5 5 4 4 3 3 2 2 1 112.5KVA TRANSFORMER BUILDING CORRIDOR MAIN DISCONNECT PANEL "H" PANEL "B" FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. C-20 ELECTRICAL LIGHTING PLAN 1 /4 "= 1'--0" ADJACENT TENANT FU/NL-EM L L FU /NL -EM CURRENT LIMITING PANEL r l FU /NL -EM FU/NL-EM FT /NL -EM FA -1 FA- FA-1 FA -1 FA -1 FA -1 FA -1 FA -1 FA -1 FA -1 FA -1 FA -1 FA -1 FA -1 -S DP) F +/ NL FJ FA -1 L FA -1 FA -1 FA -1 FA -1 FA -1 — FJ — FJ �► �TYR FJ F �NL -- - FJ/ — - - - J . '� ... • ..._ i ce ' . — _. 0____ urr. • ■� � s • o � a ® o FJ _ — � � A -7 FA -1 FA -1 FA -1 FA -1 FA -1 FA -1 FA--1 FA -1 FA -1 FA -1 ADJACENT TENANT 0 0 0 0 0 0 0 0 0 0 10 11 12 CODED NOTES: PROVIDE J -BOX AND CONDUIT TO LIGHTING CONTROL PANEL FOR EMPLOYEE ON /OFF LOW VOLTAGE KEYPAD. CONTRACTOR MUST INSTALL MANUFACTURE SUPPLIED HINGED COVER PLATE. REFER TO "LV RELAY PANEL DIAGRAM ", SHEET E5.0, FOR MORE INFORMATION. PROVIDE A CAT5 CABLE TO THE LC &D CONTROL PANEL, AND MAKE ALL FINAL CONNECTIONS, FOR CONTROL OF THE RELAYS. MOUNT EXIT SIGN AT 11' -0" ABOVE THE FINISHED FLOOR OVER THE BLIND DOOR. CONNECT EXIT SIGN TO LOCAL LIGHTING CIRCUIT, AHEAD OF ANY SWITCHING. NON -SALES NIGHT /EMERGENCY LIGHT FIXTURE. THIS FIXTURE SHALL BE CONNECTED AHEAD OF ANY SWITCHING AND HAVE A BATTERY BACKUP TO PROVIDE AT LEAST 90 MIN. OF EMERGENCY ILLUMINATION AND MAINTAIN NOT LESS THAN 60% OF THE INITIAL EMERGENCY ILLUMINATION PER NEC 700.12 (F). PROVIDE 120V 20A SWITCH FOR CONTROL OF UNDER COUNTER LIGHT FIXTURE. FEED SWITCH FROM LOAD SIDE OF GFCI RECEPTACLE. REFER TO SHEET E1.0 FOR MORE INFORMATION. PROVIDE A THREE -LAMP DUAL BALLAST RECESSED FIXTURE. ONE BALLAST SHALL CONTROL THE CENTER LAMP WHICH WILL SERVE AS AN EMERGENCY LIGHT. THIS LAMP SHALL BE CONTROLLED BY THE WALL MOUNTED OCCUPANCY SENSOR UNDER NORMAL POWER, AND TURN ON, VIA A BATTERY BACK -UP WHEN NORMAL POWER IS LOSSED, REGARDLESS OF SWITCH POSITION. THE OTHER 2 LAMPS ARE TO BE WIRED TO THE 2 CIRCUIT WALL MOTION SENSOR SWITCH ALONG WITH EXHAUST FAN. CONTRACTOR TO PROVIDE PULL BOX(ES) (SIZED PER NEC 314) FOR ALL LIGHTING CIRCUITS FEEDING THE SALES FLOOR, INCLUDING BUT NOT LIMITED TO TRACK AND COVE LIGHTING. MOUNT BOXES AS HIGH AS POSSIBLE ON BACK OF HOUSE WALL. ALL HOMERUNS FROM BACK TO PANEL ARE TO BE EMT. PROVIDE J -BOX AND CONDUIT TO LIGHTING CONTROL PANEL FOR MASTER CONTROL ON /OFF LOW VOLTAGE KEYPAD. LOW VOLTAGE BUTTONS ARE TO BE IN 2 SEPARATE BOXES, ONE FOR EACH SWITCH. CONTRACTOR MUST INSTALL MANUFACTURE SUPPLIED HINGED COVER PLATE. SEE DETAIL #2 SHEET E -2. CONTRACTOR IS TO PROVIDE A CAT -5 CABLE BACK TO THE LC &D CONTROL PANEL, AND MAKE TERMINATION AT BOTH, FOR CONTROL OF THE RELAYS. CONNECT TRACK THUR CURRENT LIMITING PANEL. REFER TO "CURRENT LIMITING PANEL DIAGRAM ", SHEET E5.0, FOR MORE INFORMATION. PROVIDE J - BOX AND A 120V, 20A DEDICATED CIRCUIT FOR REAR SKIN CARE WALL LIGHTING. COORDINATE ALL RELATED WORK WITH SEPHORA CONTACT IN FIELD. CONNECT EXIT, EMERGENCY, NIGHT LIGHT FIXTURES IN SALES AREA TO CIRCUIT A-23. PROVIDE SCREW TYPE LO'S AT THE BREAKER. COVE LIGHTS SHOWN ON PLAN ARE AN APPROXIMATION OF QUANTITY NEEDED. LIGHTING SUPPLIER SHALL PROVIDE SUFFICIENT FIXTURES TO CREATE A CONTINUOUS RUN. 1 1 GENERAL NOTES: 1 A ALL DEVICES TO BE NEW UNLESS OTHERWISE NOTED. COORDINATE LOCATION OF ALL FIXTURES AND SWITCHES WITH ARCHITECT'S DRAWINGS. B THE LIGHTING FIXTURE SUPPLIER SHALL PROVIDE FROM THE FIXTURE MANUFACTURER A COMPLETE SET OF INSTRUCTIONS FOR OPERATION AND MAINTENANCE OF THE FIXTURES. AT EACH BATTERY UNIT A LOG OF THE ORIGINAL INSTALLATION DATE AND SUBSEQUENT MAINTENANCE DATES SHALL BE POSTED. C SEE SHEET E4.0 FOR LIGHT FIXTURE SCHEDULE. D ALL NORMAL LIGHTING CIRCUITS SHALL BE CONTROLLED THROUGH LOW VOLTAGE RELAY PANELS. INSTALL LV LIGHTING CONTROL SYSTEM. SEE SHEET E5.0 FOR MORE INFORMATION. E REFER TO DETAIL B ON SHEET E4.0 FOR CONDUIT PENETRATIONS IN RATED WALLS. F FOR EMERGENCY AND EXIT LIGHTING, FEED FIXTURE FROM ADJACENT LIGHTING CIRCUIT IN THE AREA AHEAD OF THE LIGHTING CONTROL PANEL. G ALL CONDUIT HOMERUNS TO THE ELECTRICAL PANELS SHALL BE EMT ONLY. FLEXIBLE ARMORED CABLE WILL ONLY BE ALLOWED IN CONCEALED AREAS FOR BRANCH CIRCUITS WHERE IT IS ALLOWED BY CODE AND THE LANDLORD. H REFER TO DETAIL A ON SHEET E4.0 FOR CEILING EQUIPMENT /FIXTURE MOUNTING. J 1 1 1 1 1 1 11 I I I1 I 1 1 1 1 1 I1 1 1 1 1 11 1 1 1 11 II 11 1 11 1 11 I I i 1 1 1 1 11 11 11 II 1I 11 1 1 I1 II 11 1I I1 1 1 1 11 1 MALL COMMON 10 REVVED FOR CODE A 70P COMPLIANCE NEC E NF NOV 2 6 2007 City Of Tukwila BUILDING D 510N J 1 FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 TSAO 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 RMJ Robinson Meier Juilly & Associates www.rulse.corn RMJ Job No.: 07186 PROJECT LOCATION: AREA: SHEET TITLE: DRAWN BY: REVIEWED BY: SHEET NO. 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f Www.tsaodosign.com Emphasis on pence M- Retail Engineering, Inc. JOB #0712121 Structural Engineers 103 Linden Avenue So. San Francisco, CA 94080 Tel: 650.871.2282 Fax: 650.871.2459 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 98118 ELECTRICAL LIGHTI\ CL.(\I I Sri G P E2.0 5,439 SF LA PROJECT NO. 0744.03 SCALE: FF.HC:=s4la) 1/4" = ' — 0" DATE: C CT 12 07 10 -08 -07 FJM DEG D C B A MANUFACTURER PROVIDED WHIP TO MAKE -UP MIRROR. (OPTIONAL) ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS. VERIFY EXACT NUMBER WITH ARCHITECTUAL SHEETS. ---- -- , (1) DUPLEX ISOLATED GROUND RECEIPT: & (1) NORMAL POWER DUPLEX RECEPT. IN 4X4 BOX. TYPICAL (1) 1"C. EMPTY SPARE WITH PULLSTRING. SIDES TO SUPPLY POWER TO THE GENER RUN BETWEEN CASH WRAP SIDES. (1) 1 "C. W/ (9) #12 (1) 3/4 "C. RUN BETWEEN CASH WRAP / RECEPTACLES. (1) 1 -1 /2 "C. W/ (5) CAT. 5 / (1) 1- 1/2 "C. W/ (4) CAT. 5 / 1 / I CONDUIT STUB UP TYPICAL (1) DUPLEX ISOLATED GROUND REC IP & (1) NORMAL POWER DUPLEX RE EP IN 4X4 BOX. TYPICAL (4) CAT. 5 (4) CAT. 5 (1) SPARE CAT. 5 FOUR SECTION CASH WRAP DETAIL (1) SPARE CAT. 5 SECTION GONDOLA DETAIL 11� -------- ELECTRICAL CONTRACTOR IS TO PROVIDE A 6 FOOT, 2 #12 & 1 #12 GND SYPE SJO CORD AND PLUG A NEMA5 -20 FROM THE CENTER J -BOX TO THE DUPLEX OUTLET UNDER THE GONDOLA. FLUSH MOUNTED DUPLEX OUTLET FROM DETAIL H IS UNDER THE THREE AND ONE SECTION GONDOLAS AND OFFSET UNDER 2 SECTION GONDOLAS. (4) CAT. 5 (4) CAT. RECEIVING DESK DETAIL T -FRAME MOUNTED J -BOX SUPPUED BY FIXTURE MANUFACTURER. ELECTRICAL CONTRACTOR TO MAKE UP BOXES AND TO PROVIDE CONDUIT AND WIRE TO MAKE FINAL CONNECTIONS BETWEEN THE 3 GONDOLA J- BOXES. SAW CUT OPENING FOR CONDUIT, FIRE SEAL AND OR CONCRETE. VERIFY LOCATION WITH ARCH. DRAWINGS. PROVIDE PULL BUSHINGS TO PROTECT THE WIRE AND PULL STRINGS. FLEX CONDUIT CONNECTED TO EMT STUB -UP. CONDUIT SAW CUT OR CORE DRILLED (VERIFY WTTH LANDLORD) IN FLOOR. BRING TO NEAREST WALL OR COLUMN AND UP TO CEILING. E.M.T. CONDUIT CENTERED NOTE: RIGID CONDUIT SHALL BE USED FOR FLOOR PENETRATIONS. NOTE IF CASH WRAP FIXTURE COMES WITH WHITE DUPLEX RECEPTACLES IN THE ISOLATED GROUND LOCATION, REPLACE WITH ORANGE ISOLATED GROUND DEVICES. DOUBLE DUPLEX LOCATED ABOUT 48" A.F.F. (ONE DUPLEX TO BE IG AND ONE TO BE NORMAL) f PROVIDE ONE RJ -11 AND ONE RJ -45 TO JUNCTION BOX IN THIS LOCATION FOR TEMP CONTROL TERMINATE HARD PIPE AT 108" A.F.F. TEMPERATURE CONTROL UNIT, PLUGED IN TO DOUBLE DUPLEX LOCATED ABOVE. Lr STUB CONDUITS THROUGH WALL. PROVIDE INSULATED BUSHINGS ON THE END OF CONDUITS AND A PULL CORD IN EACH MOUNTING OF PULL BOX AND RECEPTACLES CAN NOT EXCEED 24" FROM WALL (WIDTH OF SAFE AREA) 0— CONNECT TO NEAREST 120V, CONVENIENCE RECEPTACLE CIRCUIT. 0— CONNECT TO NEAREST 120V, CONVENIENCE RECEPTACLE CIRCUIT. 24V SEC 24V SEC r — 1 1 NETWORK DATA 1 1 CABINET 1 24" WIDE X I 84" HIGH X I 32" DEEP I TEL /DATA TERMINAL BOARD N.T.S. PROVIDE INSULATED BUSHINGS ON THE END OF CONDUITS AND A PULL CORD IN EACH 4V, SYSTEM Z 120V TO 24V SYSTEM TRANSFORMER IN NEMA 1 ENCLOSURE. EDWARDS #590 TERMINATE ALL DATA CONDUITS AT 108" A.F.F. WITHIN THE FIRST 24" OF THE DATA BOARD ON THIS SIDE - AUIDIBLE ALARM N STROBE, EDWARDS #6536 —G5 120V TO 24V SYSTEM TRANSFORMER IN NEMA 1 ENCLOSURE. EDWARDS #592 DEDICATED (IG) DUPLEX FOR SCAN GUN LOCATED AT ABOUT 84" A.F.F. DEDICATED (IG) 30 AMP TWIST LOCK RECEPTACLE (NEMA L5 -30R) TO BE LOCATED ABOUT 18" A.F.F. CEIUNG PROVIDE A 3 GANG BOX WITH COVER PLATE FOR POWER. BUZZER IN SECURITY OFFICE, EDWARDS #C212W NON —SALES BUZZER, EDWARDS #C212W G DELIVERY BUZZER DETAIL PULL CORD STATION SEE FLOOR PLAN FOR LOCATION. EDWARDS #6537 CALL FOR ASSISTANCE DETAIL TELE /DATA GENERAL NOTES A) THIS DIAGRAM IS FOR REFERENCE PURPOSES AND MAY NOT NECESSARILY REFLECT THE EXACT ARRANGEMENT OF EQUIPMENT ON THE BACKBOARD. THIS IS THE "RECOMMENDED" PLAN, BUT STORE CONDMONS MAY PREVENT THE BACKBOARD FROM BEING LAID OUT IN THIS SPECIFIC CONFIGURATION. HOWEVER, FOR EASE OF ACCESS AND PROXIMITY OF DEVICES, EVERY EFFORT SHOULD BE MADE TO INSTALL DEVICES AS CLOSELY TO THIS EXAMPLE AS POSSIBLE. DETAIL SHOWN FOR REFERENCE ONLY. FOR EXACT EQUIPMENT SIZES COORDINATE WITH TEL /DATA CONSULTANT B) ALL RECEPTACLES ARE TO BE MOUNTED 4" IN FROM THE CLOSEST EDGE OF THE PLYWOOD. C) E.C. IS TO PROVIDE A 6 AWG CONDUCTOR TO BOND THE COMMUNICATION GROUNDING ELECTRODE AND THE POWER GROUNDING ELECTRODE SYSTEM. PROVIDE A SINGLE GANG BOX i WITH COVER PLATE FOR DATA. COUNTER TOP SECURITY COUNTER DETAIL PUSHBUTTON, SEE FLOOR PLAN FOR LOCATION. EDWARDS #1786C —B BUZZER NOTE: INSTALL A DELIVERY BUZZER SYSTEM AS SHOWN, INCLUDING EDWARDS #1786C —B PUSH BUTTON AT REAR DOOR, #590 TRANSFORMER, #C212W BUZZER IN OFFICE AND AT CASHWRAP AS INDICATED. COORDINATE ALL REQUIREMENTS WITH OWNER AS TO LOCATIONS AND QUANTITIES PRIOR TO BIDDING. CALL FOR ASSISTANCE NOTE: INSTALL AN EDWARDS MODEL #6538 —G5 CALL FOR ASSISTANCE SYSTEM AS SHOWN, INCLUDING EDWARDS #6537 PULL CORDS AT NEAR THE TOLIETS, #592 TRANSFORMER, #6536 —G5 HORN /STROBE OUTSIDE THE RESTROOMS WHERE INDICATED. VERIFY MOUNTING HEIGHTS AND REQUIREMENTS PRIOR TO BIDDING. SAW CUT /CHIP OUT EXISTING - CONCRETE SLAB AND PROVIDE WATER PROOF GROUT SEAL WALL DISP 1 CONDUIT FOR POWER WALL DISPLAY # E3..0 SECTION DISPLAY # G WALL FIXTURE POWER CONNECTION DETAIL WALL DISPLAY # OWNER PROVIDED THOMAS & BETTS - STEEEL CITY MODEL 640 OR 840SC FLOOR OUTLET CAST IRON CONCRETE TIGHT FLOOR BOX WITH THOMAS & BETTS -STEEL CITY MODEL r64 -DS-AL COVERPLATE TO BE THOMAS & BLIIS- STEEL CITY MODEL # P64-LCP ALUMINUM CARPET PLATE WITH (2) FLIP UDS AND (1) 20 AMP 120 VOLT DUPLEX RECEPTACLE. FILL BACK IN W/ CONCRETE AS NEEDED ONLY REMOVE /CHIP OUT ENOUGH CONCRETE TO CONCEAL CONDUIT. WALL DISPLAY NOTES: THREE DISPLAYS ARE WIRED TO A JUNCTION BOX LOCATED 54" FROM THE LEFT END. THIS CENTERS THE BOX ON THE 2ND SECTION OF PLUGMOLD. VERIFY CONCRETE SLAB DEPTH AND ADD CONCRETE WHERE NEEDED TO HAVE 3" MINIMUM CONCRETE UNDER FLUSH FLOOR BOX LEVELING SCREWS AT EACH CORNER CONDUIT FOR POWER - 3/4 "C. MAX. SIZE SLAB GRADE SLAB -ON -GRADE FLUSH FLOOR BOX DETAIL ELECTRICAL J -BOX AND WALL MOUNTED WIRING SUPPUED BY ELECTRICAL CONTRACTOR. MOUNT AT 48" AFF. CENTER ON FIXTURE INDICATED. PLUGMOLD PROVIDED BY FIXTURE MANUFACTURER. CONDUIT /WIRES SUPPLIED BY FIXTURE MANUFACTURER, 96" LONG — REVIEWED�N CE CODE COM NFPA 70 - NEC NOV 2 6 2007 City O f Tukwila PLAN VIEW TOP VIEW COVER PLATE AREA: SHEET TITLE: SCALE: DATE: DRAWN BY: SHEET NO. gmEmmme FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 Emphasis Excellence M- Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614. 818.2337 Robinson Meier Juilly & Associates www.rmjse.com RMJ Job No.: 07186 10 -08-07 07 -27 -07 OJECT LOCATION: REVIEWED BY: 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesign.com Structural Engineers 103 Linden Avenue So. San Francisco, CA 94080 Tel: 650. 871.2282 Fax 650.871.2459 OCT 0 4 2617 6r ISSUE FOR PERMIT CLIENT /PRELIM. LL REVIEW ISSUE DESCRIPTION JOB #0712121 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 98118 ELECTRICAL DETAILS G Zrrjl EEiiM 1 GLN 1 tr f CHECK 5,439 SF 10 -08 -07 5 5 4 4 3 3 2 1 2 1 .4• 4 .7 . • MANUFACTURER PROVIDED WHIP TO MAKE -UP MIRROR. (OPTIONAL) ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS. VERIFY EXACT NUMBER WITH ARCHITECTUAL SHEETS. ---- -- , (1) DUPLEX ISOLATED GROUND RECEIPT: & (1) NORMAL POWER DUPLEX RECEPT. IN 4X4 BOX. TYPICAL (1) 1"C. EMPTY SPARE WITH PULLSTRING. SIDES TO SUPPLY POWER TO THE GENER RUN BETWEEN CASH WRAP SIDES. (1) 1 "C. W/ (9) #12 (1) 3/4 "C. RUN BETWEEN CASH WRAP / RECEPTACLES. (1) 1 -1 /2 "C. W/ (5) CAT. 5 / (1) 1- 1/2 "C. W/ (4) CAT. 5 / 1 / I CONDUIT STUB UP TYPICAL (1) DUPLEX ISOLATED GROUND REC IP & (1) NORMAL POWER DUPLEX RE EP IN 4X4 BOX. TYPICAL (4) CAT. 5 (4) CAT. 5 (1) SPARE CAT. 5 FOUR SECTION CASH WRAP DETAIL (1) SPARE CAT. 5 SECTION GONDOLA DETAIL 11� -------- ELECTRICAL CONTRACTOR IS TO PROVIDE A 6 FOOT, 2 #12 & 1 #12 GND SYPE SJO CORD AND PLUG A NEMA5 -20 FROM THE CENTER J -BOX TO THE DUPLEX OUTLET UNDER THE GONDOLA. FLUSH MOUNTED DUPLEX OUTLET FROM DETAIL H IS UNDER THE THREE AND ONE SECTION GONDOLAS AND OFFSET UNDER 2 SECTION GONDOLAS. (4) CAT. 5 (4) CAT. RECEIVING DESK DETAIL T -FRAME MOUNTED J -BOX SUPPUED BY FIXTURE MANUFACTURER. ELECTRICAL CONTRACTOR TO MAKE UP BOXES AND TO PROVIDE CONDUIT AND WIRE TO MAKE FINAL CONNECTIONS BETWEEN THE 3 GONDOLA J- BOXES. SAW CUT OPENING FOR CONDUIT, FIRE SEAL AND OR CONCRETE. VERIFY LOCATION WITH ARCH. DRAWINGS. PROVIDE PULL BUSHINGS TO PROTECT THE WIRE AND PULL STRINGS. FLEX CONDUIT CONNECTED TO EMT STUB -UP. CONDUIT SAW CUT OR CORE DRILLED (VERIFY WTTH LANDLORD) IN FLOOR. BRING TO NEAREST WALL OR COLUMN AND UP TO CEILING. E.M.T. CONDUIT CENTERED NOTE: RIGID CONDUIT SHALL BE USED FOR FLOOR PENETRATIONS. NOTE IF CASH WRAP FIXTURE COMES WITH WHITE DUPLEX RECEPTACLES IN THE ISOLATED GROUND LOCATION, REPLACE WITH ORANGE ISOLATED GROUND DEVICES. DOUBLE DUPLEX LOCATED ABOUT 48" A.F.F. (ONE DUPLEX TO BE IG AND ONE TO BE NORMAL) f PROVIDE ONE RJ -11 AND ONE RJ -45 TO JUNCTION BOX IN THIS LOCATION FOR TEMP CONTROL TERMINATE HARD PIPE AT 108" A.F.F. TEMPERATURE CONTROL UNIT, PLUGED IN TO DOUBLE DUPLEX LOCATED ABOVE. Lr STUB CONDUITS THROUGH WALL. PROVIDE INSULATED BUSHINGS ON THE END OF CONDUITS AND A PULL CORD IN EACH MOUNTING OF PULL BOX AND RECEPTACLES CAN NOT EXCEED 24" FROM WALL (WIDTH OF SAFE AREA) 0— CONNECT TO NEAREST 120V, CONVENIENCE RECEPTACLE CIRCUIT. 0— CONNECT TO NEAREST 120V, CONVENIENCE RECEPTACLE CIRCUIT. 24V SEC 24V SEC r — 1 1 NETWORK DATA 1 1 CABINET 1 24" WIDE X I 84" HIGH X I 32" DEEP I TEL /DATA TERMINAL BOARD N.T.S. PROVIDE INSULATED BUSHINGS ON THE END OF CONDUITS AND A PULL CORD IN EACH 4V, SYSTEM Z 120V TO 24V SYSTEM TRANSFORMER IN NEMA 1 ENCLOSURE. EDWARDS #590 TERMINATE ALL DATA CONDUITS AT 108" A.F.F. WITHIN THE FIRST 24" OF THE DATA BOARD ON THIS SIDE - AUIDIBLE ALARM N STROBE, EDWARDS #6536 —G5 120V TO 24V SYSTEM TRANSFORMER IN NEMA 1 ENCLOSURE. EDWARDS #592 DEDICATED (IG) DUPLEX FOR SCAN GUN LOCATED AT ABOUT 84" A.F.F. DEDICATED (IG) 30 AMP TWIST LOCK RECEPTACLE (NEMA L5 -30R) TO BE LOCATED ABOUT 18" A.F.F. CEIUNG PROVIDE A 3 GANG BOX WITH COVER PLATE FOR POWER. BUZZER IN SECURITY OFFICE, EDWARDS #C212W NON —SALES BUZZER, EDWARDS #C212W G DELIVERY BUZZER DETAIL PULL CORD STATION SEE FLOOR PLAN FOR LOCATION. EDWARDS #6537 CALL FOR ASSISTANCE DETAIL TELE /DATA GENERAL NOTES A) THIS DIAGRAM IS FOR REFERENCE PURPOSES AND MAY NOT NECESSARILY REFLECT THE EXACT ARRANGEMENT OF EQUIPMENT ON THE BACKBOARD. THIS IS THE "RECOMMENDED" PLAN, BUT STORE CONDMONS MAY PREVENT THE BACKBOARD FROM BEING LAID OUT IN THIS SPECIFIC CONFIGURATION. HOWEVER, FOR EASE OF ACCESS AND PROXIMITY OF DEVICES, EVERY EFFORT SHOULD BE MADE TO INSTALL DEVICES AS CLOSELY TO THIS EXAMPLE AS POSSIBLE. DETAIL SHOWN FOR REFERENCE ONLY. FOR EXACT EQUIPMENT SIZES COORDINATE WITH TEL /DATA CONSULTANT B) ALL RECEPTACLES ARE TO BE MOUNTED 4" IN FROM THE CLOSEST EDGE OF THE PLYWOOD. C) E.C. IS TO PROVIDE A 6 AWG CONDUCTOR TO BOND THE COMMUNICATION GROUNDING ELECTRODE AND THE POWER GROUNDING ELECTRODE SYSTEM. PROVIDE A SINGLE GANG BOX i WITH COVER PLATE FOR DATA. COUNTER TOP SECURITY COUNTER DETAIL PUSHBUTTON, SEE FLOOR PLAN FOR LOCATION. EDWARDS #1786C —B BUZZER NOTE: INSTALL A DELIVERY BUZZER SYSTEM AS SHOWN, INCLUDING EDWARDS #1786C —B PUSH BUTTON AT REAR DOOR, #590 TRANSFORMER, #C212W BUZZER IN OFFICE AND AT CASHWRAP AS INDICATED. COORDINATE ALL REQUIREMENTS WITH OWNER AS TO LOCATIONS AND QUANTITIES PRIOR TO BIDDING. CALL FOR ASSISTANCE NOTE: INSTALL AN EDWARDS MODEL #6538 —G5 CALL FOR ASSISTANCE SYSTEM AS SHOWN, INCLUDING EDWARDS #6537 PULL CORDS AT NEAR THE TOLIETS, #592 TRANSFORMER, #6536 —G5 HORN /STROBE OUTSIDE THE RESTROOMS WHERE INDICATED. VERIFY MOUNTING HEIGHTS AND REQUIREMENTS PRIOR TO BIDDING. SAW CUT /CHIP OUT EXISTING - CONCRETE SLAB AND PROVIDE WATER PROOF GROUT SEAL WALL DISP 1 CONDUIT FOR POWER WALL DISPLAY # E3..0 SECTION DISPLAY # G WALL FIXTURE POWER CONNECTION DETAIL WALL DISPLAY # OWNER PROVIDED THOMAS & BETTS - STEEEL CITY MODEL 640 OR 840SC FLOOR OUTLET CAST IRON CONCRETE TIGHT FLOOR BOX WITH THOMAS & BETTS -STEEL CITY MODEL r64 -DS-AL COVERPLATE TO BE THOMAS & BLIIS- STEEL CITY MODEL # P64-LCP ALUMINUM CARPET PLATE WITH (2) FLIP UDS AND (1) 20 AMP 120 VOLT DUPLEX RECEPTACLE. FILL BACK IN W/ CONCRETE AS NEEDED ONLY REMOVE /CHIP OUT ENOUGH CONCRETE TO CONCEAL CONDUIT. WALL DISPLAY NOTES: THREE DISPLAYS ARE WIRED TO A JUNCTION BOX LOCATED 54" FROM THE LEFT END. THIS CENTERS THE BOX ON THE 2ND SECTION OF PLUGMOLD. VERIFY CONCRETE SLAB DEPTH AND ADD CONCRETE WHERE NEEDED TO HAVE 3" MINIMUM CONCRETE UNDER FLUSH FLOOR BOX LEVELING SCREWS AT EACH CORNER CONDUIT FOR POWER - 3/4 "C. MAX. SIZE SLAB GRADE SLAB -ON -GRADE FLUSH FLOOR BOX DETAIL ELECTRICAL J -BOX AND WALL MOUNTED WIRING SUPPUED BY ELECTRICAL CONTRACTOR. MOUNT AT 48" AFF. CENTER ON FIXTURE INDICATED. PLUGMOLD PROVIDED BY FIXTURE MANUFACTURER. CONDUIT /WIRES SUPPLIED BY FIXTURE MANUFACTURER, 96" LONG — REVIEWED�N CE CODE COM NFPA 70 - NEC NOV 2 6 2007 City O f Tukwila PLAN VIEW TOP VIEW COVER PLATE AREA: SHEET TITLE: SCALE: DATE: DRAWN BY: SHEET NO. gmEmmme FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 Emphasis Excellence M- Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614. 818.2337 Robinson Meier Juilly & Associates www.rmjse.com RMJ Job No.: 07186 10 -08-07 07 -27 -07 OJECT LOCATION: REVIEWED BY: 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesign.com Structural Engineers 103 Linden Avenue So. San Francisco, CA 94080 Tel: 650. 871.2282 Fax 650.871.2459 OCT 0 4 2617 6r ISSUE FOR PERMIT CLIENT /PRELIM. LL REVIEW ISSUE DESCRIPTION JOB #0712121 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 98118 ELECTRICAL DETAILS G Zrrjl EEiiM 1 GLN 1 tr f CHECK 5,439 SF 10 -08 -07 5 5 4 4 3 3 2 1 2 1 LIGHTING FIXTURE SCHEDULE SYMBOL DESCRIPTION DESCRIPTION MANUFACTURER & MODEL NUMBER NOTE LAMP WATTAGE VOLTAGE FA -1 2' D"X4' – D" RECESSED FLDURESCEN� LENSED TROFFLER, TRACK MOUNTED METAL HALIDE ACCENT LIGHT. LJGHTOLJER. SOF –TECH. 8338 WH (3) F32T8. 32 WATT 25 WATT. PAR38. CERAMIC 25 WATTS 120 V METAL HALIDE LAMP. 30' NARROW FLOOD, 10.000 FLUORESCENT LAMP, 2000 HOURS. 5900 LUMENS. 3000' HOURS. 2200 LUMENS. 3000' KELVIN, 81 CR1 BY PHIUPS KELVIN 82 CRI BY PHILIPS FA --1(T) SINGLE CIRCUIT TRACK AVAILABLE IN THE FOLLOWING LENGTHS: LIGHTOLJER. BASIC LYTESPAN SINGLE CIRCUIT TRACK. VERIFY WHETHER PENDANT OR SURFACE MOUNTED N/A N/A 120 V 21 WATTS 120 V 8' SERIES 600Q 07 -27 -07 E _12' , FJ I-0 �� I STAGGERED (ADJUSTABLEU5 FLUORESCENT STRIP BARTCO. BFL281 (SINGLE_LAME) 120 V 1–F28 T5. 32 WATT FLUORESCENT 32 WATTS 120 V LAMP. 2000 HOURS. 5900 LUMENS. ``'''` RECESSED EMERGENCY LIGHT FIXTURE WITH BATTERY PACK UGHTDLIER – SOLUTIONWCL 3000' KELVIN 82 CRI BY PHILIPS 72 WATTS FJ -1 STAGGERED T5 FLUORESCENT STRIP BARTCO. BFL281-2 (ADJUSTABLE TWP LAMPI BALLAST INTEGRAL WITH UNIT 2 –F28 T5. 32 WATT 64 WATTS 120 V FLUORESCENT LAMP, 2000 I 0 I 6" INCANDESCENT DOWNLIGHT LIGHTOLIER _ C6P3SD HOURS. 5900 LUMENS. 3000' KELVIN 82 CRI BY PHILIPS 120 WATTS FU METAL HALIDE LAMP 30', 1' X 4" SURFACE MOUNTED FLUORESCENT FIXTURE WITH LENSED TROFFER MERCURY MM 132 — OCL ELB SEE NOTE "B" BELOW AND COORDINATE WITH LIGHTING PLAN f 1) F32T8, 32 WATT 32 WATTS 120 V FLUORESCENT LAMP. 2000 AND WIR GU o HOURS 5900 L UMEN S . 3000' KELVIN 82 CRI BY PHILIPS �_ 1 1-0 /NL—EM 1' X 4" SURFACE MOUNTED FLUORESCENT FIXTURE WITH LENSED TROFFER MERCURY MM- 232— OCT —ELH SEE NOTE "B" BELOW C OORDINATE WITH LIGHTING PLAN (2) F32T8. 32 WATT 64 WATTS 120 V FLUORESCENT LAMP 2000 I ARD AND W GUARD HOURS 5900 LUMENS. 300D' KELVIN 82 CRI BY PHIUPS WW IMPERIA T6 WALL WASH AMERLUX – IMZW- 39– T6– E –WI –C- 120– WW –WISOR (1) 39W T6 METAL HALIDE 44 WATTS 120 V A LIGHTING FIXTURE SCHEDULE SYMBOL DESCRIPTION MANUFACTURER & MODEL NUMBER NOTE LAMP WATTAGE VOLTAGE FT I 2' D"X4' – D" RECESSED FLDURESCEN� LENSED TROFFLER, MERCURY 35E 332 OCT 9A – ELB - 120 SEE NOTE "B" BELOW AND COORDINATE Wm I LIGHTING PLAN (3) F32T8. 32 WATT 86 WATTS 120 V 0 FLUORESCENT LAMP, 2000 HOURS. 5900 LUMENS. 3000' KELVIN 82 CRI BY PHILIPS G3 1 UNDER CABINET FIXTURE ALKO QUICK INCH 0116 RSW – L – ELB (2) FSTS 21 WATTS 120 V WPK 07 -27 -07 E 2 SINGAL FACE 2 DOUBLE FACE 2 W /DIRECTIONAL ARROWS WALL MOUNTED. LED LIT. EXTT SIGN LIGHTALARM – SPLE DWRCO FIXTURE'S PROVIDED WITH BATTERY PACK TO PROVIDE 90 MINUTES OF EMERGENCY OPERATION LED LAMPS INCLUDED WITH FIXP.IRE 3.5 WATTS 120 V X6 RECESSED EMERGENCY LIGHT FIXTURE WITH BATTERY PACK UGHTDLIER – SOLUTIONWCL f2) 35W. MR16 LAMPS 72 WATTS 120 V O 0 Si 6" INCANDESCENT DOWNLIGHT LIGHTOLIER _ C6P3SD 120 WATT, PAR38, CERAMIC 120 WATTS 120 V METAL HALIDE LAMP 30', NARROW FLOOD, 2000 HOURS. 2200 LUMENS. 3000' KELVIN 81 CR1 BY PHILIPS NOTES: o 1 I /NL L 1-0 /NL—EM /NL /NL –EM /EM NIGH UQUI NIGHT LIGHT /EQUIPPED WITH BATTERY BACKUP EME!3GEN_CY LIGHT EQUIPPED WITH BATTERY BACKUP EMERGENCY LIGHT: O MINIMUM 12 GAUGE SLACK WIRE AT 45 DEGREES FROM OPPOSITE EQUIP. HOUSING CORNERS TO STRUCTURE ABOVE. ATTACH DIRECTLY TO FIXTURE WITH 3 TURN TIGHT WRAP MINIMUM. ATTACH TO STRUCTURE PER ACOUSTICAL CEIUNG ATTACHMENT DETAILS. SET WIRE SLIGHTLY SLACK, TO ALLOW FULL SEATING INTO T --BAR. FOR FIXTURES WEIGHING LESS THAN 56 POUNDS ® MINIMUM TWO #12 GAUGE SLACK WIRE AT 45 DEGREES FROM OPPOSITE FIXTURE CORNERS TO STRUCTURE ABOVE. ATTACH DIRECTLY TO FIXTURE WITH 3 TURN TIGHT WRAP MINIMUM. ATTACH TO STRUCTURE PER ACOUSTICAL CEILING ATTACHMENT DETAILS. SET WIRE SLIGHTLY SLACK, TO ALLOW FULL SEATING INTO T –BAR. 0 POSITIVELY ATTACH FIXTURE WITH METAL SCREW THROUGH T –BAR INTO FIXTURE AT OPPOSITE CORNERS. FOR FIXTURES WEIGHING 56 POUNDS OR MORE ® 12 GAUGE SUPPORT WIRES WITH THREE TURN TIGHT WRAP (WITHIN 1 1/2 ") MINIMUM AT EACH END. ATTACH TO STRUCTURE DIRECTLY ABOVE PER CEILING SUSPENSION DETAILS (4 PER FIXTURE). PENDANT HUNG FIXTURES O 9 GAUGE SUPPORT WIRES WITH THREE TURN TIGHT WRAP (WITHIN 1 1/2 ") MINIMUM AT EACH END. ATTACH TO STRUCTURE DIRECTLY ABOVE PER CEILING SUSPENSION DETAILS. T –BAR CEILING MEMBERS EQUIPMENT /FIXTURE MOUNTING NOT TO SCALE EQUIPMENT /FIXTURE MOUNTING DETAIL N.T.S. T –BAR CEILING MEMBERS NOT TO SCALE 5 FIXTURE MOUNTING DETAIL MAIN RUNNER TYPICAL RECESSED TROFFER IN HEAVY DUTY T –BAR CEILING MAIN RUNNER TYPICAL RECESSED FIXTURE CROSS RUNNER TYPICAL CEILING MID. EQUIPMENT SPEAKER, EXIT SIGN, ETC. IN HEAVY DUTY T –BAR CEILING NOTES: 1. GYP BOARD, 5/8" THICK: 1HR. – 1 LAYER, 2HR. – 2 LAYERS. 2. FILL, VOID OR CAVITY MATERIAL – CAULK: CAULK FILL MATERIAL FORCED INTO ANNULAR SPACE TO MAX. EXTENT POSSIBLE AND WITH A MIN. 1/4" DIAMETER BEAD OF CAULK APPLIED TO PERIMETER OF PIPE OR CONDUIT AT ITS EGRESS FROM THE WALL MINNESOTA MINING & MANUFACTURING CO.: TYPES SP –25 S /L, CP –25 N /S. 3. CONDUIT: NOM. 4" DIAMETER (OR SMALLER) STEEL EMT CONDUIT OR NOM. 1" DIAMETER (OR SMALLER) FLEXIBLE STEEL CONDUIT. A MAX. OF ONE PIPE OR CONDUIT IS PERMITTED IN THE FIRESTOP SYSTEM. PIPE OR CONDUIT TO BE INSTALLED NEAR CENTER OF STUD CAVITY WIDTH AND TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 4. FIRESTOP SYSTEM: INSTALLED SYMMETRICALLY ON BOTH SIDES OF WALL ASSEMBLY. THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EITHER 1 OR 2 HR. DEPENDING UPON THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. THE HOURLY T RATING FOR THE FIRESTOP SYSTEM ARE DEPENDENT UPON THE SIZE OF THE CONDUIT, THE FIRESTOP CONFIGURATION AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. THE FIRESTOP CONFIGURATION IS DEPENDENT UPON THE SIZE OF THE ANNULAR SPACE BETWEEN THE STEEL PIPE OR CONDUIT (OR PIPE COVERING) AND THE PERIMETER OF THE CIRCULAR THROUGH OPENING IN THE GYPSUM WALLBOARD LAYERS. 5. ALL FIRE STOP SYSTEMS SHALL BE UL LISTED SYSTEMS APPROVED FOR USE WITH THE SIZE AND TYPE OF PENETRATION. OBTAIN UL SYSTEM REQUIREMENTS FROM FIRE STOP MATERIAL MANUFACTURER. RATED FIRE WALT., FLOOR OR CLG. RATED FIRE WALL, FLOOR OR CLG. I B E4.0 A 4 SYSTEM WL -1001 F RATINGS – 1 AND 2 HR. SECTION A —A 11111 111111 Ill11I rI'.'. uW ImmmilIII FOR FIRE RATED WALLS SLEEVE CONDUIT -- SEE PLAN FOR SIZE & LOCATION INTUMESCENT PACKING AS REQUIRED TO MAINTAIN FIRE RATING OF ASSEMBLY SLEEVE – SEE PLAN FOR LOCATIONS FUTURE CABLE (N.I.C.) INTUMESCENT PACKING AS REQUIRED TO MAINTAIN FIRE RATING OF ASSEMBLY RATED PENATRATION DETAIL N.T.S. ANNULAR SPACE 1 1 /4" C TO 4" C-1/4" MAX 4 UNISTRUT SUPPORT EAGLE #604 PORCELAIN LAMPHOLDER WITH AN EAGLE 469B METAL LAMP GUARD AND A 100A -19 LAMP. IF BUILDING STRUCTURE IS MORE THAN 7' —O" ABOVE FINISHED CEILING, INSTALL JUNCTION BOX AND LAMPHOLDER ON A 3/4" CONDUIT SUPPORT STUB EXTENDED DOWN SO LAMPHOLDER IS NO MORE THAN 7' -0" ABOVE FINISHED CEILING. LEVITON #5299 —I COMBINATION SINGLE POLE SWITCH AND GFCI OUTLET IN SWITCHBOX LOCATED BY CEILING ACCESS PANEL /AIR DEVICE. 4.o N.T.S. 3 ALIGN BOTTOM OF FIXTURE WITH TOP OF RTU A N.T.S. NOTE: COORDINATE EXACT LOCATION OF RECEPTACLE & LIGHT WITH MECH. CONTR. SO AS NOT TO BLOCK ACCESS PANELS 4 VAV & AHU UNIT LIGHT RECEPTACLE DETAIL 3/4" RIGID GALVANIZED STEEL CONDUIT IN LIGHTING FIXTURE GENERAL NOTES ROOF OR FLOOR ABOVE. BLDG. STRUCTURE 3/4" SWITCH CONDUIT 3/4" CONDUIT TO 120 VOLT CIRCUIT. SEE FLOOR PLANS FOR CIRCUIT NUMBER. STANCHION MOUNT LIGHT FIXTURE WITH GLOBE AND GUARD AND 100W. A-21 LAMP 3/4" RIGID GALVANIZED STEEL CONDUIT LEVITON #5299 —I COMBINATION SINGLE POLE SWITCH AND GFI OUTLET IN WEATHERPROOF SWITCH BOX ROUTE CONDUIT UP THRU OPENING FINISHED ROOF SURFACE CU UNIT LIGHT RECEPTACLE DETAIL A. ALL FIXTURES TO BE PROVIDED BY SEPHORA LIGHTING SUPPLIER. B. FIXTURES TYPES "FT ", "FU" AND "FU -1" AS INDICATED WITH CODED NOTE #4 ON THE SHEET E2.0, WILL BE SUPPLIED WITH EMERGENCY BATTERY PACKS TO PROVIDE 90– MINUTES OF EMERGENCY OPERATION. 2 ELECTRICAL DEVICE LEGEND ALL SYMBOLS DO NOT NECESSARILY APPLY MOUNTING HGT. TO CENTERLINE UNLESS OTHERWISE NOTED SYMBOL DESCRIPTION 0 DQWP GFI �IG ■.. 0 -69- 3 4 K1 K2 al 1D 1 C WIRED JUNCTION BOX WIRED JUNCTION BOX DUPLEX RECEPTACLE, 3 WIRE GRD. TYPE, 20A DUPLEX RECEPTACLE, WEATHERPROOF,20A GROUND FAULT PROTECTED DUPLEX RECEPTACLE, 20A DUPLEX RECEPTACLE WITH ISOLATED GROUND QUADRAPLEX WALL RECEPTACLE, 20A DUPLEX RECEPTACLE, MOUNTED ABOVE COUNTER (1) ISOLATED GROUND RECEPTACLE AND ONE DUPLEX RECEPTACLE AS A QUADRAPLEX WALL RECEPTACLE FLOOR MOUNTED QUAD RECEPTACLE, 20A CEILING MOUNTED DUPLEX RECEPTACLE, 20A PUSHBUTTON STATION LOW VOLTAGE BUZZER TRANSFORMER DOOR BUZZER TOGGLE SWITCH — SINGLE, 3 —WAY & 4 —WAY SWITCHED CIRCUIT UNSWITCHED CIRCUIT MANUAL MOTOR STARTING SWITCH W/ PILOT LIGHT TELEPHONE OUTLET FLOOR MOUNTED TELEPHONE OUTLET DATA OUTLET — CATEGORY 5 DATA OUTLET -- DUPLEX CATEGORY 5 SAFETY SWITCH MAGNETIC MOTOR STARTER ® - I COMBINATION STARTER /SAFETY SWITCH ® MOTOR OUTLET – 1 PHASE ® MOTOR OUTLET — 3 PHASE FIRE ALARM HORN /STROBE SIGNAL DEVICE CEIUNG MOUNTED FIRE ALARM HORN /STROBE SIGNAL DEVICE FIRE ALARM STROBE SIGNAL DEVICE DUCT MTh. SYSTEM SMOKE DETECTOR W/ REMOTE INDICATORS © FIRE ALARM PULL STATION Q SYSTEM SMOKE DETECTOR TBB1 FIRE ALARM BOOSTER BOX ® KEY PAD CEILING MOUNTED MOTION SENSOR SEE DRAWINGS SEE DRAWINGS 18" 18" 18" 18" 18" 44" 18" 48" AS REQUIRED 54" 48" 48" 18" 18" 18" AS REQUIRED AS REQUIRED AS REQUIRED AS REQUIRED AS REQUIRED 80" 80" AS REQUIRED 48" CEIUNG MTh. 46" NUIE IN HANDICAPPED AREAS, THE RECEPTACLES AND TELEPHONE OUTLETS SHALL BE MOUNTED AT 24" A.F.F.; THE TOGGLE SWITCHES, THERMOSTATS AND MANUAL MOTOR STARTERS SHALL BE MOUNTED AT 42" A.F.F. EWED all CODE COMP NFPA 70 - NEC NOV 2 6 2 City O€ Ti �kwila r DING DIVISION FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. { PROJECT LOCATION: AREA: SHEET TITLE: ELECTRICAL SYv BOLS AN PROJECT NO. 0744.03 SCALE: DATE: DRAWN BY: REVIEWED BY: SHEET NO. FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 TSAO 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesign.com RMJ Robinson Meier Juiily & Associates www.rmjse.com RMJ Job No.: 07186 Emphasis On Excellence M • Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 JOB #0712121 Structural Engineers 103 Linden Avenue So. San Francisco, CA 94080 Tel: 650.871.2282 Fax: 650.871.2459 OCT o 42007 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 98118 Pi iWi; i GEN DETAILS, D LEGE E4.0 5,439 SF DS L NONE 10 -08 -07 FJM DEG / :;x_411: O I • 0 V i P. O MINIMUM 12 GAUGE SLACK WIRE AT 45 DEGREES FROM OPPOSITE EQUIP. HOUSING CORNERS TO STRUCTURE ABOVE. ATTACH DIRECTLY TO FIXTURE WITH 3 TURN TIGHT WRAP MINIMUM. ATTACH TO STRUCTURE PER ACOUSTICAL CEIUNG ATTACHMENT DETAILS. SET WIRE SLIGHTLY SLACK, TO ALLOW FULL SEATING INTO T --BAR. FOR FIXTURES WEIGHING LESS THAN 56 POUNDS ® MINIMUM TWO #12 GAUGE SLACK WIRE AT 45 DEGREES FROM OPPOSITE FIXTURE CORNERS TO STRUCTURE ABOVE. ATTACH DIRECTLY TO FIXTURE WITH 3 TURN TIGHT WRAP MINIMUM. ATTACH TO STRUCTURE PER ACOUSTICAL CEILING ATTACHMENT DETAILS. SET WIRE SLIGHTLY SLACK, TO ALLOW FULL SEATING INTO T –BAR. 0 POSITIVELY ATTACH FIXTURE WITH METAL SCREW THROUGH T –BAR INTO FIXTURE AT OPPOSITE CORNERS. FOR FIXTURES WEIGHING 56 POUNDS OR MORE ® 12 GAUGE SUPPORT WIRES WITH THREE TURN TIGHT WRAP (WITHIN 1 1/2 ") MINIMUM AT EACH END. ATTACH TO STRUCTURE DIRECTLY ABOVE PER CEILING SUSPENSION DETAILS (4 PER FIXTURE). PENDANT HUNG FIXTURES O 9 GAUGE SUPPORT WIRES WITH THREE TURN TIGHT WRAP (WITHIN 1 1/2 ") MINIMUM AT EACH END. ATTACH TO STRUCTURE DIRECTLY ABOVE PER CEILING SUSPENSION DETAILS. T –BAR CEILING MEMBERS EQUIPMENT /FIXTURE MOUNTING NOT TO SCALE EQUIPMENT /FIXTURE MOUNTING DETAIL N.T.S. T –BAR CEILING MEMBERS NOT TO SCALE 5 FIXTURE MOUNTING DETAIL MAIN RUNNER TYPICAL RECESSED TROFFER IN HEAVY DUTY T –BAR CEILING MAIN RUNNER TYPICAL RECESSED FIXTURE CROSS RUNNER TYPICAL CEILING MID. EQUIPMENT SPEAKER, EXIT SIGN, ETC. IN HEAVY DUTY T –BAR CEILING NOTES: 1. GYP BOARD, 5/8" THICK: 1HR. – 1 LAYER, 2HR. – 2 LAYERS. 2. FILL, VOID OR CAVITY MATERIAL – CAULK: CAULK FILL MATERIAL FORCED INTO ANNULAR SPACE TO MAX. EXTENT POSSIBLE AND WITH A MIN. 1/4" DIAMETER BEAD OF CAULK APPLIED TO PERIMETER OF PIPE OR CONDUIT AT ITS EGRESS FROM THE WALL MINNESOTA MINING & MANUFACTURING CO.: TYPES SP –25 S /L, CP –25 N /S. 3. CONDUIT: NOM. 4" DIAMETER (OR SMALLER) STEEL EMT CONDUIT OR NOM. 1" DIAMETER (OR SMALLER) FLEXIBLE STEEL CONDUIT. A MAX. OF ONE PIPE OR CONDUIT IS PERMITTED IN THE FIRESTOP SYSTEM. PIPE OR CONDUIT TO BE INSTALLED NEAR CENTER OF STUD CAVITY WIDTH AND TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 4. FIRESTOP SYSTEM: INSTALLED SYMMETRICALLY ON BOTH SIDES OF WALL ASSEMBLY. THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EITHER 1 OR 2 HR. DEPENDING UPON THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. THE HOURLY T RATING FOR THE FIRESTOP SYSTEM ARE DEPENDENT UPON THE SIZE OF THE CONDUIT, THE FIRESTOP CONFIGURATION AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. THE FIRESTOP CONFIGURATION IS DEPENDENT UPON THE SIZE OF THE ANNULAR SPACE BETWEEN THE STEEL PIPE OR CONDUIT (OR PIPE COVERING) AND THE PERIMETER OF THE CIRCULAR THROUGH OPENING IN THE GYPSUM WALLBOARD LAYERS. 5. ALL FIRE STOP SYSTEMS SHALL BE UL LISTED SYSTEMS APPROVED FOR USE WITH THE SIZE AND TYPE OF PENETRATION. OBTAIN UL SYSTEM REQUIREMENTS FROM FIRE STOP MATERIAL MANUFACTURER. RATED FIRE WALT., FLOOR OR CLG. RATED FIRE WALL, FLOOR OR CLG. I B E4.0 A 4 SYSTEM WL -1001 F RATINGS – 1 AND 2 HR. SECTION A —A 11111 111111 Ill11I rI'.'. uW ImmmilIII FOR FIRE RATED WALLS SLEEVE CONDUIT -- SEE PLAN FOR SIZE & LOCATION INTUMESCENT PACKING AS REQUIRED TO MAINTAIN FIRE RATING OF ASSEMBLY SLEEVE – SEE PLAN FOR LOCATIONS FUTURE CABLE (N.I.C.) INTUMESCENT PACKING AS REQUIRED TO MAINTAIN FIRE RATING OF ASSEMBLY RATED PENATRATION DETAIL N.T.S. ANNULAR SPACE 1 1 /4" C TO 4" C-1/4" MAX 4 UNISTRUT SUPPORT EAGLE #604 PORCELAIN LAMPHOLDER WITH AN EAGLE 469B METAL LAMP GUARD AND A 100A -19 LAMP. IF BUILDING STRUCTURE IS MORE THAN 7' —O" ABOVE FINISHED CEILING, INSTALL JUNCTION BOX AND LAMPHOLDER ON A 3/4" CONDUIT SUPPORT STUB EXTENDED DOWN SO LAMPHOLDER IS NO MORE THAN 7' -0" ABOVE FINISHED CEILING. LEVITON #5299 —I COMBINATION SINGLE POLE SWITCH AND GFCI OUTLET IN SWITCHBOX LOCATED BY CEILING ACCESS PANEL /AIR DEVICE. 4.o N.T.S. 3 ALIGN BOTTOM OF FIXTURE WITH TOP OF RTU A N.T.S. NOTE: COORDINATE EXACT LOCATION OF RECEPTACLE & LIGHT WITH MECH. CONTR. SO AS NOT TO BLOCK ACCESS PANELS 4 VAV & AHU UNIT LIGHT RECEPTACLE DETAIL 3/4" RIGID GALVANIZED STEEL CONDUIT IN LIGHTING FIXTURE GENERAL NOTES ROOF OR FLOOR ABOVE. BLDG. STRUCTURE 3/4" SWITCH CONDUIT 3/4" CONDUIT TO 120 VOLT CIRCUIT. SEE FLOOR PLANS FOR CIRCUIT NUMBER. STANCHION MOUNT LIGHT FIXTURE WITH GLOBE AND GUARD AND 100W. A-21 LAMP 3/4" RIGID GALVANIZED STEEL CONDUIT LEVITON #5299 —I COMBINATION SINGLE POLE SWITCH AND GFI OUTLET IN WEATHERPROOF SWITCH BOX ROUTE CONDUIT UP THRU OPENING FINISHED ROOF SURFACE CU UNIT LIGHT RECEPTACLE DETAIL A. ALL FIXTURES TO BE PROVIDED BY SEPHORA LIGHTING SUPPLIER. B. FIXTURES TYPES "FT ", "FU" AND "FU -1" AS INDICATED WITH CODED NOTE #4 ON THE SHEET E2.0, WILL BE SUPPLIED WITH EMERGENCY BATTERY PACKS TO PROVIDE 90– MINUTES OF EMERGENCY OPERATION. 2 ELECTRICAL DEVICE LEGEND ALL SYMBOLS DO NOT NECESSARILY APPLY MOUNTING HGT. TO CENTERLINE UNLESS OTHERWISE NOTED SYMBOL DESCRIPTION 0 DQWP GFI �IG ■.. 0 -69- 3 4 K1 K2 al 1D 1 C WIRED JUNCTION BOX WIRED JUNCTION BOX DUPLEX RECEPTACLE, 3 WIRE GRD. TYPE, 20A DUPLEX RECEPTACLE, WEATHERPROOF,20A GROUND FAULT PROTECTED DUPLEX RECEPTACLE, 20A DUPLEX RECEPTACLE WITH ISOLATED GROUND QUADRAPLEX WALL RECEPTACLE, 20A DUPLEX RECEPTACLE, MOUNTED ABOVE COUNTER (1) ISOLATED GROUND RECEPTACLE AND ONE DUPLEX RECEPTACLE AS A QUADRAPLEX WALL RECEPTACLE FLOOR MOUNTED QUAD RECEPTACLE, 20A CEILING MOUNTED DUPLEX RECEPTACLE, 20A PUSHBUTTON STATION LOW VOLTAGE BUZZER TRANSFORMER DOOR BUZZER TOGGLE SWITCH — SINGLE, 3 —WAY & 4 —WAY SWITCHED CIRCUIT UNSWITCHED CIRCUIT MANUAL MOTOR STARTING SWITCH W/ PILOT LIGHT TELEPHONE OUTLET FLOOR MOUNTED TELEPHONE OUTLET DATA OUTLET — CATEGORY 5 DATA OUTLET -- DUPLEX CATEGORY 5 SAFETY SWITCH MAGNETIC MOTOR STARTER ® - I COMBINATION STARTER /SAFETY SWITCH ® MOTOR OUTLET – 1 PHASE ® MOTOR OUTLET — 3 PHASE FIRE ALARM HORN /STROBE SIGNAL DEVICE CEIUNG MOUNTED FIRE ALARM HORN /STROBE SIGNAL DEVICE FIRE ALARM STROBE SIGNAL DEVICE DUCT MTh. SYSTEM SMOKE DETECTOR W/ REMOTE INDICATORS © FIRE ALARM PULL STATION Q SYSTEM SMOKE DETECTOR TBB1 FIRE ALARM BOOSTER BOX ® KEY PAD CEILING MOUNTED MOTION SENSOR SEE DRAWINGS SEE DRAWINGS 18" 18" 18" 18" 18" 44" 18" 48" AS REQUIRED 54" 48" 48" 18" 18" 18" AS REQUIRED AS REQUIRED AS REQUIRED AS REQUIRED AS REQUIRED 80" 80" AS REQUIRED 48" CEIUNG MTh. 46" NUIE IN HANDICAPPED AREAS, THE RECEPTACLES AND TELEPHONE OUTLETS SHALL BE MOUNTED AT 24" A.F.F.; THE TOGGLE SWITCHES, THERMOSTATS AND MANUAL MOTOR STARTERS SHALL BE MOUNTED AT 42" A.F.F. EWED all CODE COMP NFPA 70 - NEC NOV 2 6 2 City O€ Ti �kwila r DING DIVISION FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. { PROJECT LOCATION: AREA: SHEET TITLE: ELECTRICAL SYv BOLS AN PROJECT NO. 0744.03 SCALE: DATE: DRAWN BY: REVIEWED BY: SHEET NO. FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 TSAO 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesign.com RMJ Robinson Meier Juiily & Associates www.rmjse.com RMJ Job No.: 07186 Emphasis On Excellence M • Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 JOB #0712121 Structural Engineers 103 Linden Avenue So. San Francisco, CA 94080 Tel: 650.871.2282 Fax: 650.871.2459 OCT o 42007 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 98118 Pi iWi; i GEN DETAILS, D LEGE E4.0 5,439 SF DS L NONE 10 -08 -07 FJM DEG 10 -08 -07 ISSUE FOR PERMIT JAH WPK 07 -27 -07 CLIENT /PRELIM. LL REVIEW JAH WPK A DATE ISSUE DESCRIPTION BY CHECK O MINIMUM 12 GAUGE SLACK WIRE AT 45 DEGREES FROM OPPOSITE EQUIP. HOUSING CORNERS TO STRUCTURE ABOVE. ATTACH DIRECTLY TO FIXTURE WITH 3 TURN TIGHT WRAP MINIMUM. ATTACH TO STRUCTURE PER ACOUSTICAL CEIUNG ATTACHMENT DETAILS. SET WIRE SLIGHTLY SLACK, TO ALLOW FULL SEATING INTO T --BAR. FOR FIXTURES WEIGHING LESS THAN 56 POUNDS ® MINIMUM TWO #12 GAUGE SLACK WIRE AT 45 DEGREES FROM OPPOSITE FIXTURE CORNERS TO STRUCTURE ABOVE. ATTACH DIRECTLY TO FIXTURE WITH 3 TURN TIGHT WRAP MINIMUM. ATTACH TO STRUCTURE PER ACOUSTICAL CEILING ATTACHMENT DETAILS. SET WIRE SLIGHTLY SLACK, TO ALLOW FULL SEATING INTO T –BAR. 0 POSITIVELY ATTACH FIXTURE WITH METAL SCREW THROUGH T –BAR INTO FIXTURE AT OPPOSITE CORNERS. FOR FIXTURES WEIGHING 56 POUNDS OR MORE ® 12 GAUGE SUPPORT WIRES WITH THREE TURN TIGHT WRAP (WITHIN 1 1/2 ") MINIMUM AT EACH END. ATTACH TO STRUCTURE DIRECTLY ABOVE PER CEILING SUSPENSION DETAILS (4 PER FIXTURE). PENDANT HUNG FIXTURES O 9 GAUGE SUPPORT WIRES WITH THREE TURN TIGHT WRAP (WITHIN 1 1/2 ") MINIMUM AT EACH END. ATTACH TO STRUCTURE DIRECTLY ABOVE PER CEILING SUSPENSION DETAILS. T –BAR CEILING MEMBERS EQUIPMENT /FIXTURE MOUNTING NOT TO SCALE EQUIPMENT /FIXTURE MOUNTING DETAIL N.T.S. T –BAR CEILING MEMBERS NOT TO SCALE 5 FIXTURE MOUNTING DETAIL MAIN RUNNER TYPICAL RECESSED TROFFER IN HEAVY DUTY T –BAR CEILING MAIN RUNNER TYPICAL RECESSED FIXTURE CROSS RUNNER TYPICAL CEILING MID. EQUIPMENT SPEAKER, EXIT SIGN, ETC. IN HEAVY DUTY T –BAR CEILING NOTES: 1. GYP BOARD, 5/8" THICK: 1HR. – 1 LAYER, 2HR. – 2 LAYERS. 2. FILL, VOID OR CAVITY MATERIAL – CAULK: CAULK FILL MATERIAL FORCED INTO ANNULAR SPACE TO MAX. EXTENT POSSIBLE AND WITH A MIN. 1/4" DIAMETER BEAD OF CAULK APPLIED TO PERIMETER OF PIPE OR CONDUIT AT ITS EGRESS FROM THE WALL MINNESOTA MINING & MANUFACTURING CO.: TYPES SP –25 S /L, CP –25 N /S. 3. CONDUIT: NOM. 4" DIAMETER (OR SMALLER) STEEL EMT CONDUIT OR NOM. 1" DIAMETER (OR SMALLER) FLEXIBLE STEEL CONDUIT. A MAX. OF ONE PIPE OR CONDUIT IS PERMITTED IN THE FIRESTOP SYSTEM. PIPE OR CONDUIT TO BE INSTALLED NEAR CENTER OF STUD CAVITY WIDTH AND TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 4. FIRESTOP SYSTEM: INSTALLED SYMMETRICALLY ON BOTH SIDES OF WALL ASSEMBLY. THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EITHER 1 OR 2 HR. DEPENDING UPON THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. THE HOURLY T RATING FOR THE FIRESTOP SYSTEM ARE DEPENDENT UPON THE SIZE OF THE CONDUIT, THE FIRESTOP CONFIGURATION AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. THE FIRESTOP CONFIGURATION IS DEPENDENT UPON THE SIZE OF THE ANNULAR SPACE BETWEEN THE STEEL PIPE OR CONDUIT (OR PIPE COVERING) AND THE PERIMETER OF THE CIRCULAR THROUGH OPENING IN THE GYPSUM WALLBOARD LAYERS. 5. ALL FIRE STOP SYSTEMS SHALL BE UL LISTED SYSTEMS APPROVED FOR USE WITH THE SIZE AND TYPE OF PENETRATION. OBTAIN UL SYSTEM REQUIREMENTS FROM FIRE STOP MATERIAL MANUFACTURER. RATED FIRE WALT., FLOOR OR CLG. RATED FIRE WALL, FLOOR OR CLG. I B E4.0 A 4 SYSTEM WL -1001 F RATINGS – 1 AND 2 HR. SECTION A —A 11111 111111 Ill11I rI'.'. uW ImmmilIII FOR FIRE RATED WALLS SLEEVE CONDUIT -- SEE PLAN FOR SIZE & LOCATION INTUMESCENT PACKING AS REQUIRED TO MAINTAIN FIRE RATING OF ASSEMBLY SLEEVE – SEE PLAN FOR LOCATIONS FUTURE CABLE (N.I.C.) INTUMESCENT PACKING AS REQUIRED TO MAINTAIN FIRE RATING OF ASSEMBLY RATED PENATRATION DETAIL N.T.S. ANNULAR SPACE 1 1 /4" C TO 4" C-1/4" MAX 4 UNISTRUT SUPPORT EAGLE #604 PORCELAIN LAMPHOLDER WITH AN EAGLE 469B METAL LAMP GUARD AND A 100A -19 LAMP. IF BUILDING STRUCTURE IS MORE THAN 7' —O" ABOVE FINISHED CEILING, INSTALL JUNCTION BOX AND LAMPHOLDER ON A 3/4" CONDUIT SUPPORT STUB EXTENDED DOWN SO LAMPHOLDER IS NO MORE THAN 7' -0" ABOVE FINISHED CEILING. LEVITON #5299 —I COMBINATION SINGLE POLE SWITCH AND GFCI OUTLET IN SWITCHBOX LOCATED BY CEILING ACCESS PANEL /AIR DEVICE. 4.o N.T.S. 3 ALIGN BOTTOM OF FIXTURE WITH TOP OF RTU A N.T.S. NOTE: COORDINATE EXACT LOCATION OF RECEPTACLE & LIGHT WITH MECH. CONTR. SO AS NOT TO BLOCK ACCESS PANELS 4 VAV & AHU UNIT LIGHT RECEPTACLE DETAIL 3/4" RIGID GALVANIZED STEEL CONDUIT IN LIGHTING FIXTURE GENERAL NOTES ROOF OR FLOOR ABOVE. BLDG. STRUCTURE 3/4" SWITCH CONDUIT 3/4" CONDUIT TO 120 VOLT CIRCUIT. SEE FLOOR PLANS FOR CIRCUIT NUMBER. STANCHION MOUNT LIGHT FIXTURE WITH GLOBE AND GUARD AND 100W. A-21 LAMP 3/4" RIGID GALVANIZED STEEL CONDUIT LEVITON #5299 —I COMBINATION SINGLE POLE SWITCH AND GFI OUTLET IN WEATHERPROOF SWITCH BOX ROUTE CONDUIT UP THRU OPENING FINISHED ROOF SURFACE CU UNIT LIGHT RECEPTACLE DETAIL A. ALL FIXTURES TO BE PROVIDED BY SEPHORA LIGHTING SUPPLIER. B. FIXTURES TYPES "FT ", "FU" AND "FU -1" AS INDICATED WITH CODED NOTE #4 ON THE SHEET E2.0, WILL BE SUPPLIED WITH EMERGENCY BATTERY PACKS TO PROVIDE 90– MINUTES OF EMERGENCY OPERATION. 2 ELECTRICAL DEVICE LEGEND ALL SYMBOLS DO NOT NECESSARILY APPLY MOUNTING HGT. TO CENTERLINE UNLESS OTHERWISE NOTED SYMBOL DESCRIPTION 0 DQWP GFI �IG ■.. 0 -69- 3 4 K1 K2 al 1D 1 C WIRED JUNCTION BOX WIRED JUNCTION BOX DUPLEX RECEPTACLE, 3 WIRE GRD. TYPE, 20A DUPLEX RECEPTACLE, WEATHERPROOF,20A GROUND FAULT PROTECTED DUPLEX RECEPTACLE, 20A DUPLEX RECEPTACLE WITH ISOLATED GROUND QUADRAPLEX WALL RECEPTACLE, 20A DUPLEX RECEPTACLE, MOUNTED ABOVE COUNTER (1) ISOLATED GROUND RECEPTACLE AND ONE DUPLEX RECEPTACLE AS A QUADRAPLEX WALL RECEPTACLE FLOOR MOUNTED QUAD RECEPTACLE, 20A CEILING MOUNTED DUPLEX RECEPTACLE, 20A PUSHBUTTON STATION LOW VOLTAGE BUZZER TRANSFORMER DOOR BUZZER TOGGLE SWITCH — SINGLE, 3 —WAY & 4 —WAY SWITCHED CIRCUIT UNSWITCHED CIRCUIT MANUAL MOTOR STARTING SWITCH W/ PILOT LIGHT TELEPHONE OUTLET FLOOR MOUNTED TELEPHONE OUTLET DATA OUTLET — CATEGORY 5 DATA OUTLET -- DUPLEX CATEGORY 5 SAFETY SWITCH MAGNETIC MOTOR STARTER ® - I COMBINATION STARTER /SAFETY SWITCH ® MOTOR OUTLET – 1 PHASE ® MOTOR OUTLET — 3 PHASE FIRE ALARM HORN /STROBE SIGNAL DEVICE CEIUNG MOUNTED FIRE ALARM HORN /STROBE SIGNAL DEVICE FIRE ALARM STROBE SIGNAL DEVICE DUCT MTh. SYSTEM SMOKE DETECTOR W/ REMOTE INDICATORS © FIRE ALARM PULL STATION Q SYSTEM SMOKE DETECTOR TBB1 FIRE ALARM BOOSTER BOX ® KEY PAD CEILING MOUNTED MOTION SENSOR SEE DRAWINGS SEE DRAWINGS 18" 18" 18" 18" 18" 44" 18" 48" AS REQUIRED 54" 48" 48" 18" 18" 18" AS REQUIRED AS REQUIRED AS REQUIRED AS REQUIRED AS REQUIRED 80" 80" AS REQUIRED 48" CEIUNG MTh. 46" NUIE IN HANDICAPPED AREAS, THE RECEPTACLES AND TELEPHONE OUTLETS SHALL BE MOUNTED AT 24" A.F.F.; THE TOGGLE SWITCHES, THERMOSTATS AND MANUAL MOTOR STARTERS SHALL BE MOUNTED AT 42" A.F.F. EWED all CODE COMP NFPA 70 - NEC NOV 2 6 2 City O€ Ti �kwila r DING DIVISION FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. { PROJECT LOCATION: AREA: SHEET TITLE: ELECTRICAL SYv BOLS AN PROJECT NO. 0744.03 SCALE: DATE: DRAWN BY: REVIEWED BY: SHEET NO. FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 TSAO 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesign.com RMJ Robinson Meier Juiily & Associates www.rmjse.com RMJ Job No.: 07186 Emphasis On Excellence M • Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 JOB #0712121 Structural Engineers 103 Linden Avenue So. San Francisco, CA 94080 Tel: 650.871.2282 Fax: 650.871.2459 OCT o 42007 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 98118 Pi iWi; i GEN DETAILS, D LEGE E4.0 5,439 SF DS L NONE 10 -08 -07 FJM DEG ELECTRICAL RESPONSIBILITY SCHEDULE RELAY# FURNISHED BY INSTALLED BY RE -USE EXISTING V/N RELAY # ELEC. CONTR. LANDLORD SEPHORA OTHERS ELEC. CONTR. LANDLORD SEPHORA OTHERS MAIN OVERCURRENT DEVICE IN LANDLORD'S ELECTRIC ROOM Z11 - TRACK LIGHTING • R4 R5 A -5 • Z11 - TRACK LIGHTING A -6 R6 R7 A -7 PANEL BOARD CONDUIT TO SPACE Z11 - TRACK LIGHTING • R8 R9 A -9 • Z11 - TRACK LIGHTING A -10 R10 R11 A -11 PANELBOARD FEEDERS TO SPACE Z11 - TRACK LIGHTING • R12 R13 A -13 • Z1 - STORE FRONT UGHTING A -14 R14 R15 A -27 METER REQUIREMENTS Z1 - STORE FRONT LIGHTING • R16 R17 A -29 • Z5 - WALL WASH UGHTING A -26 R18 R19 C -3 LIGHT FIXTURES AND LAMPS Z5 - WALL WASH UGHTING A -28 • R21 • Z8 - GONDOLAS Z9 -- BACK OF HOUSE LIGHTING A -30 R22 R23 C -7 OUTLETS AND SWITCHES • A -32 R24 R25 • Z8 - GONDOLAS Z6 - 1/3 OF WALL DISPLAY C -2 R26 R27 C -11 GENERAL CONDUIT & WIRING • C -4 R28 R29 • Z8 - GONDOLAS Z7 - 2/3 OF WALL DISPLAY C -6 R30 R31 C-15 TELEPHONE CONDUIT W/ PULL WIRE Z6 - 1/3 OF WALL DISPLAY • R32 R33 C -17 • Z7 - 2/3 OF WALL DISPLAY C - 10 R34 _ R35 C -19 TELEPHONE CABLING • C -12 R36 R37 • Z8 - GONDOLAS Z6 - 2/3 OF WALL DISPLAY C-14 R38 R39 0 TELEPHONE EQUIPMENT Z6 - 1/3 OF WALL DISPLAY C -16 • R39 C-25 Z8 - GONDOLAS • C---18 R42 R39 C -27 DATA CONDUIT • C -20 R44 SPARE • Z12 - SPARE Z12 - SPARE 22 23 _23 25 27 SPARE DATA CABLING • C 0.000 SPARE • SPARE 23 24 25 26 0 -_ VIDEO /TV CONDUIT 0.180 A 0.000 0.000 SPARE SPARE 24 26 26 27 • �������� d FUTURE ODE CONiPLI/ IlittC___z,a_1;. VIDEO /TV CABLING B 0.750 0.660 0.000 INSTANT HOT DISP. WALL WASH LTS 28 29 30 • FUTURE ���� �� !� TEMPORARY UTILITY CHARGES • 0.900 0.924 • WALL WASH LTS 30 31 29 31 SPARE III O car TENANT ELECTRICAL PANELS • 0.900 C 0.600 • 0.000 32 33 30 MOTORIZED DAMPERS Cf Tukv TENANT ELECTRICAL TRANSFORMER • 0.000 NON /SALES LTS SPARE • 33 34 35 0.000 SPARE a 11 R9� TENANT FIRE ALARM SYSTEM • C A 0.000 SPARE • SPARE 35 36 37 SPARE FLOOR BOXES 0.000 0.000 • SPACE • 38 39 37 SPACE 0.000 LIGHTING CONTROL PANEL 0.300 LO • FAP • 40 41 PANEL C SPACE 0.000 0.000 LIGHITNG CONTROL PANEL LOW VOLTAGE SWITCHES 0.720 • MECHANICAL RECEP. • 42 0.000 C 8.850 T WALL MOUNTED OCCUPANCY SENSORS • SPACE 42 42 • RESPONSIBILITY SCHEDULE CODED NOTES BY OTHERS. IF , eb-..., 0 ALL FINAL CONNECTIONS TO EQUIPMENT 0 SEE POWER RISER FOR ADDITIONAL INFORMATION. 0 PANEL NAME: R1 PANEL VOLTAGE = 120V RELAY# CKT # UGHTING ZONE LIGHTING ZONE CKT # RELAY # R1 A -1 Z11 - TRACK LIGHTING Z11 - TRACK LIGHTING A -2 R2 R3 A -3 Z11 - TRACK LIGHTING Z11 - TRACK LIGHTING A -4 R4 R5 A -5 Z11 - TRACK LIGHTING Z11 - TRACK LIGHTING A -6 R6 R7 A -7 Z11 - TRACK LIGHTING Z11 - TRACK LIGHTING A -8 R8 R9 A -9 Z11 - TRACK UGHTING Z11 - TRACK LIGHTING A -10 R10 R11 A -11 Z11 - TRACK LIGHTING Z11 - TRACK LIGHTING A -12 R12 R13 A -13 Z11 - TRACK LIGHTING Z1 - STORE FRONT UGHTING A -14 R14 R15 A -27 Z2 - ILLUMINATED MIRRORS Z1 - STORE FRONT LIGHTING A -16 R16 R17 A -29 Z10 - ANIMATION WALL Z5 - WALL WASH UGHTING A -26 R18 R19 C -3 Z8 - GONDOLAS Z5 - WALL WASH UGHTING A -28 R20 R21 C -5 Z8 - GONDOLAS Z9 -- BACK OF HOUSE LIGHTING A -30 R22 R23 C -7 Z8 - GONDOLAS Z9 - BACK OF HOUSE UGHTING A -32 R24 R25 C -9 Z8 - GONDOLAS Z6 - 1/3 OF WALL DISPLAY C -2 R26 R27 C -11 Z8 - GONDOLAS Z7 - 2/3 OF WALL DISPLAY C -4 R28 R29 C -13 Z8 - GONDOLAS Z7 - 2/3 OF WALL DISPLAY C -6 R30 R31 C-15 Z8 - GONDOLAS Z6 - 1/3 OF WALL DISPLAY C--8 R32 R33 C -17 Z8 - GONDOLAS Z7 - 2/3 OF WALL DISPLAY C - 10 R34 _ R35 C -19 28 - GONDOLAS Z6 - 2/3 OF WALL DISPLAY C -12 R36 R37 C-21 Z8 - GONDOLAS Z6 - 2/3 OF WALL DISPLAY C-14 R38 R39 C -23 Z8 - GONDOLAS Z6 - 1/3 OF WALL DISPLAY C -16 R40 R39 C-25 Z8 - GONDOLAS Z5 - COVE LIGHTS C---18 R42 R39 C -27 Z8 - GONDOLAS Z5 - COVE LIGHTS C -20 R44 SPARE Z12 - SPARE Z12 - SPARE 22 23 _23 25 27 SPARE Z12 - SPARE Z12 - SPARE C 0.000 ELECTRIC LOAD SUMMARY 480Y/277V SYSTEM DESCRIPTION N.E.C. CONNECTED kVA NEC DEMAND NOTES N.E.C. DEMAND FACTOR N.E.C. DEMAND kVA LIGHTINGSCONTINUOUSL 41.388 - [1] [2] t25 51.735 24.038 TRACK LIGHT DEMAND ALLOWANCE - SHOW WINDOW DEMAND ALLOWANCE - [31 - 5.475 KIT APPLIANCE 0.000 [4 1.00 0.000 11.090 RECEPTACLES 12.180 (Si - MOTORS 0.280 [6] - 0.350 FIXED ELECTRIC SPACE HEATING 0.000 [6],[71 - I 0.000 AIR CONDITIONING SYSTEM 50.025 I - 53.250 ELECTRIC WATER HEATER 2.430 [81 1.2 7 3.038 MISCELLANEOUS 4.560 - 1.0 4.560 TOTAL N.E.C. DEM. KVAX 1000 110.863 TOTAL -- 153.535 FEEDER AMPERAGE AMPS = MINIMUM = 184.7 SYS. VOLTAGE X 1.732 - -- 153.535 X 1000 480 X 1.732 ELECTRIC LOAD SUMMARY (TRANSFORMER) 208Y/120V LOADS DESCRIPTION LIGHTING (CONTINUOUS N.E.C. CONNECTED kVA NEC DEMAND NOTES [1] [ N.E.C. DEMAND FACTOR N.E.C. DEMAND kVA 41.388 - 1.25 51.735 24.038 TRACK LIGHT DEMAND ALLOWANCE SHOW WINDOW DEMAND ALLOWANCE - [ - 1.00 5.475 KIT APPLIANCE 0.000 [4 0.000 RECEPTACLES 11180 [5] 16] [6],[7] - 11.090 MOTORS 0.280 - 0.350 FIXED ELECTRIC SPACE HEATING 0.000 CL4 0.000 AIR CONDITIONING SYSTEM 0.000 [ ] - 0.000 ELECTRIC WATER HEATER 2.430 [8] 1.2 3.038 MISCELLANEOUS 4.560 - FEEDER AMPERAGE AMPS 1.0 4.560 7_ N.E.C. DEM. KVA X 1000 60.838 36 100.285 = MINIMUM = 278.4 CL9 SYS. VOLTAGE X 1.732 100.285 X 1000 208 X 1.732 PANEL NAME: R1 PANEL VOLTAGE = 120V �� V U Z PANEL CKT NO. TRACK LENGTH FT. CL BREAK AMPS UGHTING ZONE LIGHTING ZONE CL BREAK AMPS TRACK LENGTH FT. PANEL CKT NO. CL CKT NO. CL1 A -1 16 4 Z11 - TRACK UGHTING Z11 - TRACK LIGHTING 4 36 A -2 CL2 CL3 A -3 36 6 Z11 - TRACK UGHTING Z11 - TRACK UGHTING 4 36 A -4 CL4 CL5 A -5 36 8 Z11 - TRACK LIGHTING Z11 - TRACK UGHTING 8 36 A -6 CL6 CL7 A-7 36 6 711 - TRACK UGHTING Z11 - TRACK LIGHTING 8 36 A -8 CL8 CL9 A-9 36 8 Z11 - TRACK UGHTING Z11 - TRACK LIGHTING 6 36 A -10 CL1O CL11 A -11 36 8 Z11 - TRACK UGHTING Z11 - TRACK LIGHTING 8 36 A -12 CL12 CL13 A -13 36 6 Z11 - TRACK LIGHTING Z1 - STORE FRONT LIGHTING 6 20 A -14 CL14 CL15 0.510 13 0.510 SPARE SPARE TRACK LIGHTING 0.360 A CL16 CL17 30/1 UPS TWIST LOCK (i CONVENIENCE RECEP. SPARE SPARE 0.420 LTG. CONTROL PANEL CL18 CL19 B 1.200 SPARE SPARE MUX CAMERA POWER 0.000 Lo CL20 CL21 1.260 ENTRY LTS 1.400 SPARE 17 18 19 21 EMPLOYEE TIMECLOCK ELECTRICAL CONNECTION SCHEDULE UNIT VOLTAGE FLA MCA MOCP A/POLE GROUNDED AND UNGROUNDED CONDUCTORS CONDUCT SWITCH DISCONNECT AT UNIT CIRCUIT CONNECTION NOTES VAV -1 480V, 3 PHASE 15.23 18.64 20/3 (3) #12 THWN & (1) #12 GND 3/4" 30A, 3- POLE, NONFUSED H- 7/9/11 0.850 VAV -2 480V, 3 PHASE 15.23 18.64 20/3 (3) #12 THWN & (1) #12 GND 3/4" 30A, 3 -POLE, NONFUSED H- 8/10/12 LO _ VAV -3 480V, 3 PHASE 13.63 17.04 20/3 (3) #12 THWN & (1) #12 GND 3/4" 30A, 3 -POLE, NONFUSED H- 13/15/17 TRACK LIGHTING VAV -4 480V, 1 PHASE 15.23 18.64 40/3 (3) #12 THWN & (1) #12 GND 3/4" 30A, 3 -POLE, NONFUSED H- 2/4/6 6 • d U Zone Load Description Brkr. Size * Brkr. Opts. N.E.C. kVA 4* Phase N.E.C. kVA .-. Brkr. Opts. Brkr. Size * Load Description Zone Ckt. No. 1 TRACK LIGHTING CASH REGISTER (IG) Lo 0.180 A 0.850 TRACK LIGHTING REFRIGERATOR 2 2 3 TRACK LIGHTING CASH REGISTER (IG) B LO 0.180 B 1.130 WPK TRACK LIGHTING GARBAGE DISPOSAL 4 4 5 TRACK LIGHTING CASH REGISTER (IG) ISSUE DESCRIPTION Lo 0.180 C 0.600 2/3 WALL DISPLAY TRACK LIGHTING MICROWAVE 6 7 GONDOLAS CASH REGISTER (IG) 20/3 LO 0.180 A 0.360 Lo 20/3 TEL/DATA BOARDLG1 TEL/DATA BOARD 1.400 _6 8 10 12 9 C CASH REG. RECEP. 2/3 WALL DISPLAY 0.360 B C 0.360 0.180 Lo 11 1.400 ADMIN RECEP (IG) 11 0.000 0.540 2/3 WALL DISPLAY SCAN GUN (IG) 0.510 13 0.510 ADMIN RECEP (IG) TRACK LIGHTING 0.360 A 2.800 30/1 UPS TWIST LOCK (i CONVENIENCE RECEP. 14 16 15 0.420 LTG. CONTROL PANEL STORE FRONT LTS 0.100 B 1.200 17 1/3 WALL DISPLAY MUX CAMERA POWER 0.000 Lo 1.200 C 1.260 ENTRY LTS 1.400 CONVENIENCE RECEP. 17 18 19 21 EMPLOYEE TIMECLOCK 0.000 C 0.180 A 0.540 SPARE CONVENIENCE RECEP. 19 20 21 21 RECEIVING (IG) 0.000 A 0.180 B 0.280 SPARE TF -1, EF -1 21 22 23 _23 25 27 SPARE B 0.000 C 0.000 SPARE 0.000 SPARE 23 24 25 26 EWH -1 20/2 0.900 0.180 A 0.000 0.000 SPARE SPARE 24 26 26 27 ILLUMINATION MIRROR 27 1.500 B 0.750 0.660 0.000 INSTANT HOT DISP. WALL WASH LTS 28 29 30 HVAC CONTROL PANEL 28 0.500 C 0.900 0.924 STORE FRONT RECEP. WALL WASH LTS 30 31 29 31 SPARE SPARE _ SIGN 0.000 A 0.900 C 0.600 STORE FRONT RECEP. 0.000 32 33 30 MOTORIZED DAMPERS A 0.500 B 0.000 NON /SALES LTS SPARE SPARE 33 34 35 0.000 SPARE 0.000 C A 0.000 SPARE _ SPARE - SPARE 35 36 37 SPARE _ 0.000 0.000 SPACE SPACE 38 39 37 SPACE 0.000 B 0.300 LO 39 FAP T 40 41 PANEL C SPACE 0.000 0.000 C 0.720 1oor3 MECHANICAL RECEP. 40 42 Ckt No. Zone Load Description Brkr. Size Brkr. Opts. N.E.G. kVA Phase N.E.C. kVA Brkr. Opts. Brkr. Size Load Description Zone • d U Z 1 TRACK LIGHTING VAV -1 VAV -3 0.270 A 0.300 4.300 TRACK LIGHTING VAV -2 2 3 20/3 TRACK LIGHTING 4.300 B 0.390 B 0.120 JAH WPK TRACK LIGHTING 07 -27 -07 4 5 WPK TRACK LIGHTING DATE ISSUE DESCRIPTION 0.480 C 0.600 2/3 WALL DISPLAY TRACK LIGHTING A 6 7 GONDOLAS TRACK LIGHTING 20/3 HACR 0.450 A 0.660 HACR 20/3 TRACK LIGHTING 1.400 S 9 C TRACK LIGHTING 2/3 WALL DISPLAY 0.480 B 0.270 GONDOLAS TRACK LIGHTING 1.400 10 11 0.000 TRACK LIGHTING 2/3 WALL DISPLAY 0.510 C 0.510 GONDOLAS TRACK LIGHTING 0.000 12 13 TRACK LIGHTING 2/3 WALL DISPLAY 0.390 A 0.420 GONDOLAS STORE FRONT LTS C 14 15 SPARE 1/3 WALL DISPLAY 0.000 B 0.100 0.000 A ENTRY LTS 1.400 16 17 SPARE 21 0.000 C 0.000 0.000 B SPARE 18 19 SPARE 21 0.000 A 0.000 0.000 C SPARE 20 21 22 SPARE _23 25 27 0.000 B 0.000 1.400 22.434 SPARE 0.000 22 23 NL/EM SALES 26 LO 0.900 C 0.000 B 0.000 SPARE 24 26 25 28 ILLUMINATION MIRROR 27 1.000 A 0.660 0.000 B WALL WASH LTS 27 30 SKIN CARE LIGHTS 28 29 0.300 B 0.924 0.000 WALL WASH LTS 0.000 28 29 31 _ SPARE _ SIGN _ 31 0.000 C 0.600 0.000 NON /SALES LTS 0.000 30 1.200 A 0.500 32 33 NON /SALES LTS SPARE 32 33 0.000 SPARE 0.000 0.000 B 0.000 34 35 SPARE _ SPARE - 34 35 SPACE SPACE 0.000 C 0.000 SPACE SPACE 36 38 37 10.054 A 6.530 39 T 39 PANEL C 125/3 0.000 10.450 B C 6.840 1oor3 PANEL B 40 41 0.000 C 8.850 T 6.080 SPACE 42 Z Zone Load Description I m Brkr. Opts. N.E.C. kVA .* Phase N.E.C. kVA .,. Brkr. Opts. Brkr. Size * Load Description Zone Ckt. No. 1 VAV -1 VAV -3 4.300 A 4.300 VAV -2 2 20/3 HACR 4.300 B 4.300 10 -08 -07 ISSUE FOR PERMIT JAH WPK 07 -27 -07 CLIENT /PRELIM. LL REVIEW JAH WPK A DATE ISSUE DESCRIPTION BY CHECK Z Zone Load Description I m Brkr. Opts. N.E.C. kVA .* Phase N.E.C. kVA .,. Brkr. Opts. Brkr. Size * Load Description Zone Ckt. No. 1 VAV -1 VAV -3 4.300 A 4.300 VAV -2 2 20/3 HACR 4.300 B 4.300 HACR 20/3 4 6 8 10 2/3 WALL DISPLAY 5 4.300 C 4.300 1.400 C 1 _ 2/3 WALL DISPLAY 3.775 A 4.300 GONDOLAS VAV-4 20/3 HACR 3.775 B 4.300 HACR 20/3 1.400 B 3.775 C 4.300 2/3 WALL DISPLAY 10 12 13 GONDOLAS 1.400 0.000 A 0.000 2/3 WALL DISPLAY 14 15 177 19 GONDOLAS 0.000 B 0.000 2/3 WALL DISPLAY 16 18 15 GONDOLAS 0.000 C 0.000 0.450 1/3 WALL DISPLAY 16 17 19 0.000 A 0.000 1.400 C 0.550 20 21 18 GONDOLAS 0.000 B 0.000 COVE LTS 22 21 1.400 0.000 C 0.000 SPARE 22 24 _23 25 27 GONDOLAS TRANSFORMER 1.400 22.434 A 0.000 SPARE 24 26 175/3 19.874 B 0.000 0.000 SPARE 28 29 27 GONDOLAS 18.530 C 0.000 B 0.000 30 • d U Zone Load Description mi Brkr. Opts. N.E.C. kVA Phase N.E.C. kVA Brkr. Opts. Brkr. Size * Load Description Zone Ckt. No. 1 SPARE 0.000 A 1.200 1/3 WALL DISPLAY CV 'Kt 3 GONDOLAS 1.400 B 1.500 2/3 WALL DISPLAY 5 GONDOLAS 1.400 C 1.200 2/3 WALL DISPLAY CO FCO N a, GONDOLAS 1.400 A 1.500 1/3 WALL DISPLAY GONDOLAS 1.400 B 1.500 2/3 WALL DISPLAY 10 11 GONDOLAS 1.400 C 1.500 2/3 WALL DISPLAY 12 13 GONDOLAS 1.400 A 1.050 2/3 WALL DISPLAY 14 15 GONDOLAS 1.400 B 0.450 1/3 WALL DISPLAY 16 17 19 GONDOLAS 1.400 C 0.550 COVE LTS 18 GONDOLAS 1.400 A 0.704 COVE LTS 20 21 GONDOLAS 1.400 B 0.000 SPARE 22 23 GONDOLAS 1.400 C 0.000 SPARE 24 25 GONDOLAS 1.400 A 0.000 SPARE 26 27 GONDOLAS 1.400 B 0.000 SPARE 28 29 SPARE 0.000 C 0.000 SPACE 30 31 SPARE 0.000 A 0.000 SPACE 32 33 SPARE -_ 0.000 B 0.000 SPACE 34 35 _ SPARE - ^ 0.000 C 0.000 SPACE 36 37 SPACE 0.000 A 0.000 SPACE 38 39 SPACE 0.000 B 0.000 SPACE 40 41 SPACE 0.000 C 0.000 SPACE 42 5 5 4 LANDLORD TO PROVIDE 4 #350MCM AND 1 #1/0 GRD. IN LANDLORD PROVIDED 3" CONDUIT. TENANT PROVIDED 1" CONDUIT FOR TELECOMMUNICATIONS. CONDUIT SHALL BE TERMINATED AT LANDLORD CABLE TRAY LOCATED IN SERVICE CORRIDOR. VERIFY EXACT LOCATION PRIOR TO BIDDING.- - Panelboard Panel Type NEMA Type NOTE: FINAL CONNECTION TO SWITCHGEAR BY LANDLORDS E.C. AT TENANTS EXPENSE EXISTING 277/480V, 30, 4W, LANDLORD SWITCHBOARD LOCATED IN ELECTRICAL ROOM. FIELD VERIFY EXACT REQUIREMENTS PRIOR TO BIDS. Panelboard Panel Type NEMAType _ METER AND METER SOCKET PER POWER CO. REQUIREMENTS. FLOOR "A" NQOD °C" NQOD 1 E Existing Circuit to remain IG Isolated Ground Circuit LANDLORD SHALL PROVIDE 300A /3P CIRCUIT BREAKER IN LANDLORD'S SWITCH GEAR. 300A LL'S ELECTRIC RM POWER RISER DIAGRAM NTS POWER RISER GENERAL NOTES: ALL NEW TERMINATIONS SHALL BE 75' C RATED A HVAC CIRCUIT BREAKERS SHALL BE "HACR" TYPE WHERE REQUIRED BY EQUIPMENT NAMEPLATE PER N.E.C. B TENANT'S ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXACT A.I.C. RATING OF LANDLORD'S DISTRIBUTION EQUIPMENT, FURNISH AND INSTALL TENANTS SYSTEM TO MATCH. C ELECTRICAL CONTRACTOR SHALL BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT TO ±10% BETWEEN PHASES: A/B B /C, A/C REGARDLESS OF CIRCUITING INDICATED. D PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.C. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. E ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. F TENANT'S NAME AND SPACE NUMBER SHALL BE APPLIED TO DISCONNECT SWITCH AT SWITCHGEAR WITH BLACK PLASTIC LAMENT WITH WHITE LETTERS. G TENANT'S ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BID. VERIFY EXACT OVER CURRENT PROTECTION /DISCONNECT REQUIREMENTS (PER N.E.C. #140) WITH EQUIPMENT MANUFACTURER NAMEPLATE DATA UPON RECEIPT AT JOB SITE. CONTACT ENGINEER WITH ANY DISCREPANCIES. ELECTRICAL CONTRACTOR TO MAKE ALL FINAL ELECTRICAL POWER CONNECTIONS. Voltage OCPD Mounting 208Y/120 400A M.C.B. SURFACE Notes * All circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted. All Phases to be balanced to within 10% using Actual Load Totals. N.E.C. Connected Totals: Ph.A N.E.C. Connected Totals: Ph.B N.E.C. Connected Totals: Ph.0 Total E Existing Circuit to remain IG Isolated Ground Circuit Connected Load: 168.9 NEC 2005 Demand Feeder Load: 278.2 Voltage 208Y/120 OCPD M.L.O. Mounting SURFACE Notes * All circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted. All Phases to be balanced to within 10% using Actual Load Totals. N.E.C. Connected Totals: Ph.A N.E.C. Connected Totals: Ph.B N.E.C. Connected Totals: Ph.0 Total Connected Load: Phase 3 Wire 4 Buss 400A 22.434 19.874 18.530 60.838 Phase Wire Buss 10.054 10.450 8.850 29.354 kVA kVA kVA kVA amps amps 3 4 225A kVA kVA kVA kVA 81.5 amps NEC 2005 Demand Feeder Load: 101.9 amps APPROX. 125' VERIFY EXACT DISTANCE) LEASE LINE Options/Notes AIC Rating TELEPHONE BOARD TENANT SPACE Breaker Options: AS Powerlink AS Breaker LO Handle lock -on device ST Shunt Trip Type AUX Auxiliary Contacts PA Handle Padlock Attachment GFCI Ground Fault Circuit Interrupter HACR Heating, NC & Refrigeration SF Subfeed AFCI Arc Fault Circuit Interrupter Options/Notes AIC Rating Breaker Options: AS Powerlink AS Breaker LO Handle lock -on device ST Shunt Trip Type AUX Auxiliary Contacts PA Handle Padlock Attachment GFCI Ground Fault Circuit Interrupter HACR Heating, NC & Refrigeration SF Subfeed AFCI Arc Fault Circuit Interrupter 10,000 10,000 4 #350MCM AND 1 #1/0 GRD. IN 3" CONDUIT. -.. LANDLORD PROVIDED 400A /3P FUSED DISCONNECT SWITCH, WITH LANDLORD PROVIDED 300A FUSES. TENANT TO RELOCATE IF REQUIRED, AND EXTEND WIRE AND CONDUIT AS NEEDED. 112.5 KVA TRANSFORMER 480V, 30 DELTA PRI. 120/ 208V, 30, 4W WYE SEC. - 0 POWER RISER CODED NOTES: 1 MASTER LIGHTING CONTROL PANEL PROVIDED BY LIGHTING SUPPLIER. SEE RELAY CONTROL PANEL SCHEDULE, THIS SHEET, FOR WIRING AND ZONE REQUIREMENTS. PROVIDE (1) CAT5 CONTROL CABLE BETWEEN THE MASTER AND THE SLAVE LIGHTING PANEL. 2 REFER TO "CURRENT LIMITING DETAIL ", THIS SHEET FOR MORE INFORMATION. Panelboard Panel Type NEMA Type Notes * All circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted. "* All Phases to be balanced to within 10% using Actual Load Totals. N.E.C. Connected Totals: Ph.A N.E.C. Connected Totals: Ph.B N.E.C. Connected Totals: Ph.0 Total Panelboard Panel Type NEMA Type PANEL "HP" 277/480V. 30, 4W, 300A M.C.B. "B HOOD "HP" NQOD 1 2" MIN. 1 3 #2/0 THWN AND 1 #6 GRD. IN 2" CONDUIT. Voltage OCPD Mounting Notes * All circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted. All Phases to be balanced to within 10% using Actual Load Totals. N.E.C. Connected Totals: Ph.A N.E.C. Connected Totals: Ph.B N.E.C. Connected Totals: Ph.0 Total E Existing Circuit to remain IG Isolated Ground Circuit Connected Load: NEC 2005 Demand Feeder Load: MICARTA LABEL TYIPICAL FOR ALL PANELS 208Y/120 M.L.O. SURFACE E Existing Circuit to remain 1G Isolated Ground Circuit Connected Load: 54.0 NEC 2005 Demand Feeder Load: 52.7 PANEL » 120/208V, 30, 4W FED FROM PANEL "A" Voltage 480Y/277 OCPD 300A M.C.B. Mounting SURFACE 4" MIN. PANEL "A" 120/208V, 30, 4W, 400A M.C.B. 4 #600 MCM THWN AND 1 #1/0 GRD. IN 3 -1/2" CONDUIT. #1/0 GRD. TO BLDG. STEEL PER NEC. 6.530 kVA 6.840 kVA 6.080 kVA 19.450 kVA 39.109 kVA 36.549 kVA 35.205 kVA 110.863 kVA 133.4 amps 184.7 amps LC &D CURRENT LIMITING PANEL. CURRENT LIMITING PANEL GENERAL NOTES 1. CURRENT LIMITING PANEL PROVIDED BY OWNERS LIGHTING FIXTURE SUPPLIER. PANEL SHALL BE LC &D T24CL 21 CIRCUIT SILVER BULLET PANEL. 2. THE CIRCUITING SHOWN ON THE PLAN CORRESPONDS TO THE LIGHTING CONTROL SCHEME, IF THE CIRCUITING IS CHANGED IN THE FIELD THE ELECTRICAL CONTRACTOR SHALL CONTACT THE ENGINEER AND NOTIFY THEM OF THE CHANGES IN WRITING. 3. ROUTE ALL TRACK LIGHTING CIRCUITS FROM BREAKER PANEL TO CURRENT LIMITING PANEL LANDING EACH TRACK ON THE INPUT SIDE OF THE SUPPLEMENTARY BREAKER DESIGNATED BY LC &D. WIRE FROM THE OUTPUT SIDE OF EAC SUPPLEMENTARY BREAKER TO THE MASTER LCP. LANDING EACH CIRCUIT ON THE UNE TERMINAL DESIGNATED BY LC &D. ALL OTHER LIGHTING CIRCUITS SHALL BE ROUTED THROUGH LCP PER MFG. SCHEDULE. Phase 3 Wire 4 Buss 225A amps amps Phase 3 Wire 4 Buss 450A Options/Notes AIC Rating Options/Notes AIC Rating 0 Breaker Options: AS Powerlink AS Breaker LO Handle lock -on device ST Shunt Trip Type AUX Auxiliary Contacts PA Handle Padlock Attachment GFCI Ground Fault Circuit Interrupter HACR Heating, A/C & Refrigeration SF Subfeed AFCI Arc Fault Circuit Interrupter Breaker Options: AS Powerlink AS Breaker LO Handle lock -on device ST Shunt Trip Type AUX Auxiliary Contacts PA Handle Padlock Attachment GFCI Ground Fault Circuit Interrupter HACR Heating, NC & Refrigeration SF Subfeed AFCI Arc Fault Circuit Interrupter -4 #1 THWN, AND 1 #6 GRD. IN 1-1/2" CONDUIT. MASTER LC &D LIGHTING CONTROL PANEL. 0 4 #3 THWN, 1 #8 GRD. AND 1 #8 ISOLATED GRD. IN 1 -1/2" CONDUIT. 10,000 14,000 PANEL "C" 120/208V, 30, 4W, 225A M.L.O LOAD SUMMARY NOTES: [ [ [3] [4] [5] [ [ [ PANEL "B" 120/208V, 30, 4W, 225A M.L.O. FLOOR CURRENT LIMITER PANEL PANEL "A" 0 POWER FACTOR IS ALREADY INCLUDED IN LIGHTING LOAD. 150VA/2FT OF LINE VOLTAGE TRACK + SUM LOW VOLTAGE XFRMS - CONNECTED LOAD 200VA/LF - ACTUAL CONNECTED LOAD KIT APPLIANCE DEMAND FACTOR PER NEC 220-20 0.0 < 10KW = 100%, REMAINING - 50% 125% OF THE LARGEST MOTOR OR COMPRESSOR IN SYSTEM APPLIED ON ONE UNIT. USE GREATER VALUE OF THESE TWO CATEGORIES 125% DEMAND FACTOR FOR TANK TYPE, 100% FOR INSTANT HOT LV RELAY PANEL NOTES 1 LOW VOLTAGE LIGHTING CONTROL PANEL PROVIDED BY OWNERS' LIGHTING FIXTURE SUPPLIER. LOW VOLTAGE LIGHTING CONTROL SYSTEM COMPLETE WITH PROGRAMMABLE TIME CLOCK, LV RELAYS, AND LV MASTER CONTROL SWITCHING. REFER TO SCHEDULE AND PARTIAL RISER DIAGRAM FOR CONTROL ZONING AND CAPACITY. 2 THE CIRCUITING SHOWN ON THE PLAN CORRESPONDS TO THE LIGHTING CONTROLS SCHEME. IF THE CIRCUITING IS CHANGED IN THE FIELD THE ELECTRICAL CONTRACTOR SHALL CONTACT THE ENGINEER AND NOTIFY THEM OF THE CHANGES IN WRITING. 3 ELECTRICAL CONTRACTOR SHALL COORDINATE WITH SEPHORA AND MALL LANDLORD FOR PROGRAMMING TIMECLOCK SCHEDULES. THE ELECTRICAL CONTRACTOR SHALL PROVIDE THE GENERAL CONTRACTOR WITH THE OPERATIONS MANUAL AFTER THE JOB IS COMPLETE. A COPY OF THE RELAY SCHEDULE WITH ANY FIELD CONDITION CHANGES IDENTIFIED SHALL BE LEFT IN THE DOOR OF THE LC &D RELAY PANEL. 4 ELECTRICAL CONTRACTOR SHALL CALL LC &D TO PERFORM DIAGNOSTIC TEST AT COMPLETION OF INSTALLATION. CURRENT LIMITING BREAKER PANEL OUT ,T Y 0 LIVING LOADS TC T LIGHTING CONTROL PANEL CURRENT LIMITING PANEL CODED NOTES 1. ROUTE ALL TRACK LIGHTING CIRCUITS FROM BREAKER PANEL TO T24CL LANDING EACH TRACK CIRCUIT ON THE INPUT SIDE OF THE SUPPLEMENTARY BREAKER DESIGNATED BY LC &D. 2. WIRE FROM THE OUTPUT SIDE OF EACH SUPPLEMENTARY BREAKER TO THE MASTER LCP, LANDING EACH CIRCUIT ON THE LINE TERMINAL DESIGNATED BY LC &D. 3. ROUTE ALL OTHER LIGHTING CIRCUITS THROUGH LCP PER SCHEDULE. 4. 4" X 4" X 60" GUTTER MOUNTED BELOW OR ABOVE PANELS. CURRENT LIMITING PANEL DIAGRAM N.T.S LIGHTING ZONES Z1 - STORE FRONT LIGHTING Z2 - WALL MOUNT SALES Z3 "5" DOXES AND DLADE SIGNS Z4 -- SIGNS AND EXTERIOR LIGHTING Z5 - COVE LIGHTING /REAR SKIN CARE Z6 - 1/3 OF WALL DISPLAY Z7 - 2/3 OF WALL DISPLAY ZB - GONDOLAS /LIGHTED MIRRORS Z9 - BACK OF HOUSE LIGHTING Z10 - ANIMATION WALL Z11 - TRACK LIGHTING Z12 - SPARE STAFF LIGHTING SHALL CONSIST OF: Z1 - STORE FRONT LIGHTING Z3 "S" BOXES & BLADE CICNS Z5 - COVE LIGHTING Z6 - 1/3 OF WALL DISPLAY Z9 - BACK OF HOUSE LIGHTING MASTER CONTROL IN ELECTRICAL AREA Z1 Z2 Z3 Z7 STAFF LIGHTING ALL OFF D ENTRANCE CONTROL SWITCHES AT STAGE DOOR (SW1) 1 LANDLORD NOTES: ELECTRICAL CONTRACTOR SHALL UTILIZE LANDLORD PROVIDED FUSED DISCONNECT SWITCH LOCATED WITHIN THE TENANT SPACE FOR TEMPORARY ELECTRIC FOR CONSTRUCTION. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY TRANSFORMER AND PANEL AS REQUIRED WITHIN TENANT SPACE. 2 LANDLORD PROVIDED MASTER METERING EQUIPMENT IN THE LANDLORD'S ELECTRICAL ROOM. THE LANDLORD OWNED NETWORK METERING SYSTEM WILL METER TENANT POWER CONSUMPTION. U 0 Z8 Z9 U I] Z4 Z5 Z6 Z10 Z11 Z12 L CATAGORY 5, 4 TW PAIR - BY ELEC. CONTRACTOR FROM BRANCH CIRCUIT PANEL 20"Wx38 "Hx6 "D MASTER LIGHTING CONTROL PANEL GR2400 -> LIGHTING LOADS NOTE: ELECTRICAL CONTRACTOR SHALL TERMINATE ALL CAR -5 CABLE FROM SEITCHES TO TERMINALS IN LC &D PANEL MASTER LIGHTING CONTROL PANEL LV RELAY PANEL DIAGRAM N.T.S FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. 4 3 2 1 1 AREA: SHEET TITLE: SCALE: DATE: DRAWN BY: REVIEWED BY: SHEET NO. FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 TSAO 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesign.com Emphasis On Excalsrms M. Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 RMJ Robinson Meier Juilly & Associates wwwamjse.cam RMJ rob No.: 07186 PROJECT LOCATION: JOB #0712121 Structural Engineers 103 Linden Avenue So. San Francisco, CA 94080 TeL 650.871.2282 Fax 650.871.2459 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 981 18 POWER RISER & SCHEDULES PROJECT NO. 0744.03 10 -08 -07 i r i 7 .. 1 Pbi-iM;I GEN -�`r E5.0 OCT 0 4 2007 5,439 SF NONE FJM DEG D C B A GENERAL CONDITIONS: ELECTRICAL SPECIFICATIONS A. THE REQUIREMENTS AS SET FORTH UNDER GENERAL CONDITIONS, INSTRUCTIONS TO BIDDERS AND GENERAL REQUIREMENTS ARE A PART OF THIS CONTRACT. B. BIDS SHALL BE BASED ON A COMPLE It/FULL SET OF DRAWINGS. C. CONTRACTOR MUST READ THE ENTIRE SPECIFICATIONS COVERING OTHER BRANCHES OF WORK AND IS RESPONSIBLE FOR COORDINATION OF THE WORK WITH WORK PERFORMED BY OTHER TRADES. SCOPE OF WORK: A. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS. ALL REQUIREMENTS INCLUDING MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS ARE TO BE OBTAINED BY ELECTRICAL CONTRACTOR PRIOR TO AND INCLUDED IN BID PRICE. FIELD VERIFY ALL EXISTING ELECTRICAL AND TELEPHONE EQUIPMENT, LOCATIONS, CONDITIONS ETC. FAILURE TO VISIT THE SITE SHALL NOT RELIEVE THE CONTRACTOR FROM ANY RESPONSIBIU1 Y IN THE PERFORMANCE OF THE ELECTRICAL WORK. B. FURNISH ALL LABOR, MATERIALS, TESTING, EQUIPMENT, INCIDENTALS AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. 1. MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW AND AS SUCH APPEAR ON THE UNDERWRITERS LABORATORIES LIST OF APPROVED ITEMS AND SHALL BE SIZED IN CONFORMITY WITH REQUIREMENTS OF THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND OTHER APPLICABLE CODES, WHICHEVER ARE MORE STRINGENT. C. THE WORK IS TO BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NEC AND ALL APPUCABLE FEDERAL, STATE AND LOCAL CODES. D. INCLUDE ANY LABOR AND MATERIALS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO PROVIDE A COMPLETE AND FULLY OPERATIVE ELECTRICAL SYSTEMS. PERMITS: A. SECURE AND PAY FOR ALL REQUIRED PERMITS, FEES, ASSESMENTS AND INSPECTION CERTIFICATES THAT RELATE TO THE ELECTRICAL CONTRACT. B. FURNISH APPROVED CERTIFICATE OF FINAL INSPECTION, AND TURN OVER TO OWNER AT COMPLETION OF PROJECT. DRAWINGS AND SPECIFICATIONS: A. THIS ELECTRICAL PLANS ARE DIAGRAMMATIC, NOT SHOWING EVERY ITEM IN EXACT LOCATION OR DETAIL. MEASUREMENTS AND LOCATIONS MUST BE FIELD VERIFIED AND COORDINATED WITH ARCHITECTURAL, PLUMBING, HVAC, FIRE PROTECTION, FIRE ALARM, STRUCTURAL, AND OTHER BUILDING DRAWINGS. SHOP DRAWINGS: A. SUBMIT FIVE COPIES OF MATERIAL LISTS AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE OWNER'S CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS EARLY ENOUGH IN PROJECT TO ALLOW AMPLE TIME FOR OWNER'S REVIEW WITHOUT CAUSING TIME DELAYS OR CONFUCTS IN THE JOB PROGRESS. SUBMITTALS SHALL BE IN ACCORDANCE WITH GENERAL CONDITIONS AND THE MANUFACTURERS LISTED ON THE DRAWINGS AND SHALL BEAR THE STAMP OF THE CONTRACTOR SHOWING THAT HE HAS REVIEWED AND APPROVED THEM AND THAT THEY ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS. LACK OF SUCH CONTRACTOR'S APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY THE OWNER. B. WHERE TRADE NAMES, BRANDS OF MANUFACTURERS OF EQUIPMENT OR MATERIALS ARE SHOWN ON THE DRAWINGS OR SPECIFICATIONS THE EXACT EQUIPMENT SHALL BE USED ON THE PROJECT. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL /REPLACEMENT AT THE REQUEST OF THE OWNER'S CONSTRUCTION MANAGER (AT THE ELECTRICAL CONTRACTORS EXPENSE). CONDUITS: A. CONDUIT SHALL BE STANDARD STEEL RIGID, IMC OR EMT (THIN WALL) ACCORDING TO LOCAL CODE AND LANDLORD REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FINISHED AREAS, EXCEPT AS OTHERWISE APPROVED BY ARCHITECT. EMT CONNECTIONS SHALL BE COMPRESSION OR SET SCREW TYPE. B. FLEXIBLE CONDUIT OR TYPE MC CABLE SHALL BE USED FOR FINAL CONNECTIONS TO LIGHT FIXTURES, MOTORS AND VIBRATING EQUIPMENT ONLY; AND WHERE SO USED TO BE GROUNDED WITH A SEPARATE FULL SIZED GREEN GROUNDING CONDUCTOR. FINAL TYPE MC /FLEX CONNECTIONS SHALL BE LIMITED TO 6' -0" IN LENGTH. (ARRANGE CIRCUITS SO AS TO AVOID THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILING AREAS, JUNCTION BOXES LOCATED ABOVE LAY —IN CEILINGS ARE ACCEPTABLE.) 1. MINIMUM SIZES OF CONDUITS SHALL BE 3/4" FOR STANDARD CONDUIT, AND 1/2" FOR FLEX CONDUIT (1/2" STANDARD CONDUIT AND 3/8" MC CABLE MAY BE USED AS SPECIFIED ABOVE, IF ACCEPTABLE WITH LANDLORD AND LOCAL CODES, ELECTRICAL CONTRACTOR SHALL FIELD COORDINATE WITH LANDLORD & INSPECTION AGENCIES PRIOR TO INSTALLATION). ELECTRIC METALUC TUBING (EMT) SHALL BE GALVANIZED OR ELECTRO—GALVANIZED. FITTINGS SHALL BE SET SCREW OR COMPRESSION TYPE, FITTING SHALL BE AS MANUFACTURED BY REGEL, STEEL CITY, RACO, T & B, EFCOR OR EQUAL. EMT SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS RUN ABOVE SUSPENDED CEILINGS OR CONCEALED IN INTERIOR PARTITIONS. 2. PAINTING OF ELECTRICAL CONDUITS, ETC., IF REQUIRED, WILL BE BY GENERAL CONTRACTOR. C. THE USE OF ROMEX OR BX IS NOT PERMITTED. D. MAXIMUM CONDUIT HANGER SPACING SHALL BE 8' -0" FOR 3/4" THRU 1 1/4" AND 10' -0" FOR 1 1/2" THRU 4" CONDUITS. DO NOT SUPPORT CONDUIT FROM THE CEILING SYSTEM. E. LEAVE A #10 AWG PULL WIRE OR NYLON PULL STRING IN ALL EMPTY CONDUITS. F. SECURE ALL RACEWAYS TO THE BUILDING STRUCTURE IN A RIGID AND SECURE MANNER, USING FASTENERS SUCH AS "CADDY CUPS" OR EQUAL. G. FLASH AND COUNTERFLASH ALL RACEWAYS WHICH PENETRATE THE ROOF OR USE PITCH POCKETS. INSURE THAT PENETRATIONS ARE COMPLETELY WEATHERPROOF. ALL RACEWAY SYSTEMS EXPOSED TO THE WEATHER SHALL BE WEATHERPROOF. PRIOR APPROVAL BY LANDLORD IS REQUIRED TO ADD ADDITIONAL EQUIPMENT LOADS TO STRUCTURE OR TO MAKE HOLES IN EXISTING ROOF. NOTIFY LANDLORD'S ROOFING CONTRACTOR AT LEAST 72 HOURS PRIOR TO ANY REQUIRED ROOF WORK. WIRE: A. WIRE SHALL BE SINGLE CONDUCTOR COPPER WITH 600 VOLT INSULATION. MINIMUM WIRE SIZE SHALL BE #12 AWG, ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. ALL WIRING OF ANY TYPE SHALL BE IN CONDUIT. NO STRANDED WIRE ALLOWED FOR #10 AND #12 AWG SIZES. (INCREASE CONDUCTOR BY ONE SIZE FOR EVERY 150' INCREMENT OF DISTANCE FROM THE PANEL BOARD FOR 120 VOLT CIRCUITS.) 1. GENERAL WIRING SHALL BE THW OR THHN. (ALUMINUM CONDUCTORS ARE NOT PERMITTED.) B. WIRE CONNECTORS SHALL BE EQUAL TO SCOTCHLOCK FOR #8 AND SMALLER, AND EQUAL TO T & B "LOCK -11TE" FOR #6 AND LARGER. C. THE USE OF SHARED NEUTRALS IS ACCEPTABLE FOR LIGHTING AND RECEPTACLE CIRCUITS IF INSTALLED IN ACCORDANCE WITH N.E.C. #310, AND LOCAL CODES. D. ALL WIRING TO BE COLOR CODED AS FOLLOWS: UGHTING: A. UGHTING FIXTURES AND LAMPS SHALL BE FURNISHED AS SCHEDULED ON THE UGHTING FIXTURE SCHEDULE. (THE MAJORITY OR THE FIXTURES AND LAMPS ARE FURNISHED BY THE TENANT) ELECTRICAL CONTRACTOR SHALL INSTALL ALL FIXTURES AND LAMPS. FLUORESCENT FIXTURES SHALL HAVE HPF BALLASTS WITH EFFICIENCY FACTORS IN ACCORDANCE WITH "INTERNATIONAL ENRGY CONSERVATION CODE 2001." B. LIGHT FIXTURES SHALL BE SUPPORTED FROM THE BUILDING STRUCTURAL VIA ALL THREAD AND UNI— STRUT, AND NOT SUPPORTED BY CEILING SYSTEM. WIRED GROUND SYSTEM: A. FURNISH AND INSTALL A COMPLETE WIRED GROUNDING SYSTEM FOR ELECTRICAL EQUIPMENT AND CIRCUITS AS SHOWN ON THE DRAWINGS AND DESCRIBED GENERALLY BELOW. B. ALL GROUNDING CONDUCTORS SHALL BE GREEN, WHERE EXPOSED IN PANEL, SWITCHBOARD, OUTLET, BOXES, ETC. C. ALL ENCLOSURES AND NON— CURRENT CARRYING METALS TO BE GROUNDED. CONDUIT SYSTEM TO BE ELECTRICALLY CONTINUOUS. ALL LOCK NUTS MUST CUT THROUGH ENAMELED OR PAINTED SURFACES ON ENCLOSURES. WHERE ENCLOSURES AND NON— CURRENT CARRYING METALS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS WITH APPROVED CLAMPS. D. RUN A SEPARATE GROUNDING CONDUCTOR IN EACH CONDUIT, #12 MINIMUM, OR AS SHOWN ON DRAWINGS. FOR PANEL FEEDERS BOND THE GROUNDING CONDUCTOR TO THE CONDUIT, WHERE ENTERING AND LEAVING THE CONDUIT. ALL GROUND CLAMPS SHALL BE PENN — UNION OR EQUAL, SIMILAR TO "GPL" TYPE. CONDUIT GROUND BUSHINGS SHALL BE THOMAS & BETTS OR EQUAL, SIMILAR TO #3800 SERIES WITH NYLON INSULATED THROAT. E. ALL DEVICES SHALL BE BONDED TO THE CONDUIT SYSTEM. USE A BONDING JUMPER BETWEEN THE OUTLET BOX AND THE DEVICE GROUNDING TERMINAL. METAL—TO—METAL CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX IS NOT ACCEPTABLE AS A BOND FOR EITHER SURFACE MOUNTED BOXES OR FLUSH TYPE BOXES. ALL JUNCTION BOXES, OUTLET BOXES AND PULL BOXES SHALL BE BONDED TO THE CONDUIT SYSTEM. ALL FLEXIBLE CONDUIT SHALL BE JUMPERED WITH A GROUND CONDUCTOR. WIRE DEVICES: 120/208 VOLT SYSTEM NEUTRAL — WHITE PHASE A OR L1 —BLACK PHASE B OR L2 —RED PHASE C OR L3 —BLUE GROUND —GREEN 277/480 VOLT SYSTEM NEUTRAL — WHITE WITH TRACER OR GRAY PHASE A OR L1 — BROWN PHASE B OR L2— ORANGE PHASE C OR L3 —YELLOW GROUND —GREEN WITH TRACER A. COLOR OF WIRING DEVICES AND COVERPLATES SHALL BE SELECTED BY ARCHITECT. (SEE PLAN NOTES FOR ADDITIONAL INFORMATION). 1. RECEPTACLES SHALL BE 20 AMP, 3 —WIRE GROUNDING TYPE EQUAL TO HUBBELL 5362. 2. SWITCHES SHALL BE 20 AMP SPECIFICATION GRADE, RATED AT 120 OR 277 VOLT, AS REQUIRED. 3. SPECIAL DEVICES SHALL BE A SPECIFICATION GRADE. 4. EQUAL BY ARROW —HART, GENERAL ELECTRIC, BRYANT, PASS & SEYMOUR, OR SIERRA. PANELBOARDS AND SAFETY SWITCHES: A. PROVIDE BRANCH CIRCUIT PANELS WHICH SHALL BE OF THE BOLTED CIRCUIT BREAKER TYPE WITH SOLID COPPER BUSSING FULL SIZED NEUTRAL, 25% GROUND BUSSING, OVERALL HINGED /LOCKABLE DOOR, AND TYPEWRITTEN DIRECTORY INSIDE DOOR. ALL SERVICE ENTRANCE EQUIPMENT SHALL BEAR THE MANUFACTURER'S LABEL WHICH SHALL STATE THAT THE EQUIPMENT IS RATED FOR SERVICE ENTRANCE APPLICATION IN ACCORDANCE WITH N.E.C. #230 -70. LOAD BALANCE ALL ELECTRICAL PHASES AT PANELS AND SWITCHBOARDS. TWO AND THREE POLE BREAKERS SHALL BE COMMON TRIP TYPE. WHEN USED AS SWITCHES IN 120V. AND 277V. UGHTING CIRCUITS, FURNISH TYPE "SWD" BREAKERS IN ACCORDANCE WITH N.E.C. #240 -83B. SQUARE D OR EQUAL BY SIEMENS ITE, CUTLER — HAMMER, OR GENERAL ELECTRIC (OR APPROVED EQUAL). B. PROVIDE SAFETY AND DISCONNECT SWITCHES, FUSED OR NONFUSED, AS CALLED FOR ON DRAWINGS AND AS REQUIRED BY CODE. (FUSES AS MANUFACTURED BY BUSSMAN, CHASE SHAWMUT, ECONOMY FUSE CO., OR LITTLE FUSE CO. ARE ACCEPTABLE). DISCONNECT SWITCHES THAT ARE INSTALLED AT AIR CONDITIONING EQUIPMENT, HEAT PUMPS, ETC SHALL BE FUSED IN ACCORDANCE WITH THE EQUIPMENT'S NAME PLATE REQUIREMENTS PER N.E.C. 440 -21 & 110 -3B. SWITCHES SHALL BE HEAVY DUTY, QUICK MAKE /QUICK BREAK TYPE, FUSIBLE OR NON— FUSIBLE, WEATHERPROOF AS INDICATED ON THE DRAWINGS, OR AS REQUIRED BY LOCAL CODES. LOAD AND HORSEPOWER RATED AS MANUFACTURED BY SQUARE D, SIEMENS ITE, CUTLER HAMMER, OR GENERAL ELECTRIC (OR APPROVED EQUAL). C. MANUAL MOTOR STARTERS WITH OVERLOAD PROTECTION MAY BE USED FOR FRACTIONAL HORSEPOWER MOTORS THAT DO NOT REQUIRE AUXILIARY CONTROL. SINGLE PHASE STARTERS SHALL BE SQUARE D OR EQUAL. THREE PHASE STARTERS SHALL BE PROVIDED WITH OVERLOAD DEVICE IN EACH PHASE MATCHED TO MOTOR NAMEPLATE RATING. MAGNETIC MOTOR STARTERS (MINIMUM SIZE #1) SHALL BE USED FOR ALL SINGLE PHASE AND THREE PHASE MOTORS RATED ABOVE 1/2 HP OR THAT REQUIRE AUXIUARY CONTROL. PROVIDE CONTROL DEVICES (CONTACTS, TRANSFORMERS, ETC.) IN STARTERS AS REQUIRED FOR INTERLOCKS, COORDINATE WITH MECHANICAL AND /OR TEMPERATURE CONTROL CONTRACTORS. COMBINATION STARTERS, WHEN USED, SHALL CONTAIN FUSIBLE SWITCHES. BOXES: A. OUTLET BOXES AND COVERS PRESSED STEEL KNOCKOUT. B. JUNCTION, PULL BOXES AND CODE GAUGE SIZE. C. INSTALL BOXES RIGIDLY ON BUILDING STRUCTURE AND SUPPORT INDEPENDENTLY OF THE CONDUIT SYSTEM. ALSO PROVIDE SUITABLE /PROPER BOX EXTENSIONS TO EXTEND BOXES TO FINISHED FACES OF WALLS ETC. ALL OUTLET BOXES TO HAVE SUITABLE BLOCKING BEHIND THEM TO MINIMIZE THE DEFLECTION THAT OCCURS WHEN PLUGGING /UNPLUGGING INTO THESE DEVICES. D. WHERE A 277 VOLT LIGHT SWITCH IS GANGED WITH A 120 VOLT RECEPTACLE PROVIDE A SUITABLE DIVIDER OR SEPARATE JUNCTION BOXES IN ACCORDANCE WITH NEC AND LOCAL CODES. SERVICES: SHALL BE GALVANIZED, ONE —PIECE COVERS SHALL BE GALVANIZED STEEL, A. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY SERVICE FROM LANDLORD'S DESIGNATED LOCATION AND PROVIDE LIGHTING, POWER AND WIRING AS REQUIRED TO FACIUTATE APPUCABLE TEMPORARY NEEDS, AND FURNISH EXTENSION CORDS. ANY TEMPORARY WRING, FUSES, ETC., SHALL BE REMOVED UPON COMPLETION OF THE PROJECT. PROVIDE GROUND FAULT PROTECTION AS REQUIRED BY N.E.C. AND LOCAL CODES. B. PROVIDE ELECTRICAL SERVICE AS SHOWN ON THE DRAWINGS, FIELD VERIFY EXACT REQUIREMENTS PRIOR TO BIDS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR POWER COMPANY SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE ENTIRE INSTALLATION WITH LANDLORD AND POWER COMPANY AS REQUIRED. (PROVIDE EQUIPMENT THAT IS COMPATIBLE WITH AVAILABLE FAULT CURRENT LEVELS, PROVIDE "CABLE UMITERS" IF NECESSARY FOR SYSTEM COORDINATION). FIELD VERIFY EXACT TYPE, SIZE, LOCATION, REQUIREMENTS, ETC. OF EXISTING POWER AND TELEPHONE FACILITIES PRIOR TO BIDDING PROJECT. C. MAKE PROVISIONS FOR NEW TELEPHONE SERVICE AS REQUIRED, AND AS INDICATED ON THE DRAWINGS. D. CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION WITHIN TENANT'S PREMISES SHALL BE PROVIDED AS REQUIRED FOR A COMPLETE TELEPHONE SYSTEM. OUTLET BOXES SHALL BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. CLOSELY FIELD COORDINATE WITH TENANTS CONSTRUCTION MANAGER TO AVOID CONFLICTS. STEP —DOWN TRANSFORMER: (IF APPUCABLE) A. PROVIDE DRY —TYPE TRANSFORMER AS MANUFACTURED BY SQUARE "D" , HEAVY DUTY, ACME, GENERAL ELECTRIC, SIEMENS ITE OR OTHER EQUIVALENT MANUFACTURERS, OF THE ENCLOSED VENTILATED TYPE WITH KVA AND VOLTAGE RATINGS AS CALLED FOR ON THE DRAWINGS WITH COILS DESIGNED FOR 150 DEGREE C RISE ABOVE A 40 DEGREE C AMBIENT WITH 100% OF RATED LOAD CONNECTED TO THE SECONDARY, CLASS 220 DEGREE C INSULATION AND A MINIMUM OF SIX STANDARD FULL CAPACITY TAPS (TWO ABOVE AND FOUR BELOW NORMAL). SOUND LEVEL /DECIBELS SHALL BE IN ACCORDANCE WITH "NEMA" STANDARDS, AND INSTALLATION SHALL INCLUDE "KORFOUND" OR EQUAL VIBRATION— DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY CONNECTIONS TO MINIMIZE SOUND TRANSMISSION. MOUNT TRANSFORMER ON SEPARATE VIBRATION ISOLATORS. THESE ARE ADDITIONAL VIBRATION ISOLATORS AND ARE USED IN CONJUNCTION WITH ANY INTEGRAL FACTORY INSTALLED VIBRATION ISOLATORS. LANDLORD'S NOTES: 1 ALL CABLING SHALL BE PLENUM RATED. ALL TENANTS SERVED BY LANDLORD'S AIR CONDITIONING UNIT HAVE PLENUM RETURNS. LIGHTING CONTACTOR AND TIMER SWITCHES: A. B. INSTALLATION: CONTACTORS FOR CONTROL OF LIGHTING AND SIGNS SHALL BE SQUARE "D ", CLASS 8903, TYPE "L ", ELECTRICALLY HELD. EQUIVALENT PRODUCTS BY OTHER MANUFACTURERS ARE PERMITTED. ELECTRONIC DIGITAL TIME SWITCHES SHALL BE USED FOR CONTROL OF SHOW WINDOW LIGHTING, SIGNS, AND IF REQUIRED /DESIRED OTHER LIGHTING. THE ELECTRONIC DIGITAL TIMER SHALL BE A TORK MODEL DWZ100A OR EQUIVALENT WITH A 7 —DAY FORMAT, 365 DAY ADVANCED HOLIDAY SCHEDULE, CAPABLE OF DIFFERENT SETTINGS EACH DAY OF THE WEEK, AND HAVE AN ASTRONOMIC FEATURE. A. ALL ELECTRIC WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIRING. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE FASTENED TO BUILDING STEEL, CONCRETE OR MASONRY, BUT NOT PIPING OR DUCTWORK. ALL CONDUIT SHALL BE CONCEALED WHEREVER POSSIBLE. EXPOSED CONDUITS SHALL BE IN STRAIGHT ONES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES OR BEAMS AND SEPARATED AT LEAST 3 INCHES FROM WATER LINES WHEREVER THEY RUN ALONGSIDE OR ACROSS SUCH UNES. ALL CONDUCTORS SHALL BE IN CONDUIT, DUCTS OR OTHER CODE APPROVED RACEWAYS. B. ALL LINE AND LOW VOLTAGE POWER AND CONTROL WIRING (EXCEPT HVAC LOW VOLTAGE WIRING) INCLUDING CONNECTIONS TO MOTORS, DAMPERS, INTERLOCKING, ETC., SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. (ALL LINE VOLTAGE WIRING, CONDUIT, AND FINAL CONNECTIONS FROM THE POWER SOURCE THRU THE STARTER /DISCONNECT ETC. TO THE MOTOR OR EQUIPMENT IS THE RESPONSIBILITY OR THE ELECTRICAL CONTRACTOR. ALL HVAC RELATED LOW VOLTAGE CONTROL WIRING, CONDUIT AND FINAL CONNECTIONS IS THE RESPONSIBILITY OF THE MECHANICAL /TEMPERATURE CONTROL CONTRACTOR, UNLESS OTHERWISE NOTED ON THE PLANS). C. THE ELECTRICAL CONTRACTOR SHALL DO ALL CUTTING, CHASING OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK UNDER THE ELECTRICAL DIVISION, ANY CUTTING SHALL HAVE PRIOR APPROVAL OF THE LANDLORD. SLEEVES SHALL EXTEND AT LEAST TWO (2 ") INCHES ABOVE FINISHED FLOOR AND ALL SLEEVES, OPENINGS, ETC., THROUGH FIRE RATED WALLS AND FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL BY HIL11 AFTER CONDUIT /CABLES INSTALLATION SO AS TO RETAIN THE FIRE RATING. D. THE ELECTRICAL CONTRACTORS, INSOFAR AS THE WORK IS CONCERNED, SHALL AT ALL TIMES KEEP THE PREMISES IN A NEAT AND ORDERLY CONDITION AND, AT THE COMPLETION OF THE WORK, SHALL PROPERLY CLEAN UP AND CART AWAY ANY DEBRIS AND EXCESS MATERIAL. E. THE FOLLOWING EQUIPMENT SHALL BE IDENTIFIED WITH ENGRAVED BAKELITE NAMEPLATES AS TO NAME AND /OR FUNCTION; DISTRIBUTION PANELS, LIGHTING PANELS, MOTOR STARTERS AND DISCONNECT SWITCHES. NAMEPLATES TO BE APPROXIMATELY 1" X 2" IN SIZE AND BE FASTENED WITH POP RIVETS OR SCREWS. F. THE LOCATION OF OUTLETS AND EQUIPMENT SHOWN ON THE DRAWINGS ARE APPROXIMATE AND THE ARCHITECT /TENANT CONSTRUCTION MANAGER SHALL HAVE THE RIGHT TO RELOCATE ANY OUTLETS OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. G. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN THE WORK AS THE JOB PROGRESSES, AND TURN THIS "AS BUILT" INFORMATION OVER TO THE OWNER AT THE COMPLETION OF THE PROJECT. H. ELECTRICAL CONTRACTOR SHALL PROTECT ALL FIXTURES /EQUIPMENT AGAINST DAMAGE FROM LEAKS, ABUSE, ETC., AND PAY COST OF REPAIR OR REPLACEMENT OF FIXTURES OR EQUIPMENT MADE NECESSARY BY FAILURE TO PROVIDE SUITABLE SAFEGUARDS OR PROTECTION. I. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. AFTER ALL EQUIPMENT HAS BEEN INSPECTED AND APPROVED, THOROUGHLY CLEAN ALL EQUIPMENT PROVIDED UNDER THIS WORK JUST PRIOR TO COMPLETION OF PROJECT. J. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ANY /ALL NECESSARY ELECTRICAL DEMOLITION WORK THAT IS REQUIRED TO FACILITATE THE NEW INSTALLATION, FIELD COORDINATE PRIOR TO BIDS. REMOVE AND /OR MODIFY EQUIPMENT, ETC. AS REQUIRED FOR A COMPLETE INSTALLATION. ANY EQUIPMENT OR DEVICE REMAINING IN USE AFTER PART OF THE EQUIPMENT OR DEVICES HAVE BEEN REMOVED ARE TO BE RECONNECTED TO EXISTING OR NEW CIRCUITS AND LEFT IN WORKING ORDER. FEEDERS TO PANELS AND WIRING TO OTHER EQUIPMENT TO BE ROUTED CONCEALED IN FINISHED AREAS. COORDINATE ANY DISRUPTION OF ELECTRICAL OR TELEPHONE SERVICES WITH LANDLORD AND TENANT CONSTRUCTION MANAGER TO AVOID CONFLICTS. GUARANTEE: A. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THE ELECTRICAL CONTRACTOR'S EXPENSE. B. FOR THE SAME PERIOD, ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND /OR INSTALLED BY THE ELECTRICAL CONTRACTOR. FINALLY: A. IT IS THE INTENT THAT THE FOREGOING WORK SHALL BE COMPLETE IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. REVIEWED F O R CODE COMPLIANCE EC NFPA NOV 2 C • �l�y flf Tukwila B ILDING DIVISION AREA: TSAO REVIEWED BY: SHEET NO. FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 Nrr PROJECT LOCATION: 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesign.com Embank, On lnea M• Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 RMJ Robinson M eie r Juilly & Associates www.rmjse.com RMJ Job No.: 07186 GON JOB 0712121 Structural Engineers 103 Linden Avenue So. San Francisco, CA 94080 Tel: 650.871.2282 Fax 650.8712459 13 4.2 35495 IONAL h =rs 07 / t OCT 042007 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 981 18 E6.0 5,439 SF DEG 5 5 4 4 I 1 3 3 2 2 1 1 SHEET TITLE: ELECTRICAL SPECIFICATIO\S PROJECT NO. 0744.03 SCALE: DATE: DRAWN BY: CITY OF _ t J � NONE E+F- i- e'i.4.i• r+ - -•.• • • v�1V1�C( 10 -08-07 FJM D C B 10 -08-07 ISSUE FOR PERMIT JAH WPK 07 -27 -07 CLIENT /PRELIM. LL REVIEW JAH WPK A DATE ISSUE DESCRIPTION BY CHECK GENERAL CONDITIONS: ELECTRICAL SPECIFICATIONS A. THE REQUIREMENTS AS SET FORTH UNDER GENERAL CONDITIONS, INSTRUCTIONS TO BIDDERS AND GENERAL REQUIREMENTS ARE A PART OF THIS CONTRACT. B. BIDS SHALL BE BASED ON A COMPLE It/FULL SET OF DRAWINGS. C. CONTRACTOR MUST READ THE ENTIRE SPECIFICATIONS COVERING OTHER BRANCHES OF WORK AND IS RESPONSIBLE FOR COORDINATION OF THE WORK WITH WORK PERFORMED BY OTHER TRADES. SCOPE OF WORK: A. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS. ALL REQUIREMENTS INCLUDING MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS ARE TO BE OBTAINED BY ELECTRICAL CONTRACTOR PRIOR TO AND INCLUDED IN BID PRICE. FIELD VERIFY ALL EXISTING ELECTRICAL AND TELEPHONE EQUIPMENT, LOCATIONS, CONDITIONS ETC. FAILURE TO VISIT THE SITE SHALL NOT RELIEVE THE CONTRACTOR FROM ANY RESPONSIBIU1 Y IN THE PERFORMANCE OF THE ELECTRICAL WORK. B. FURNISH ALL LABOR, MATERIALS, TESTING, EQUIPMENT, INCIDENTALS AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. 1. MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW AND AS SUCH APPEAR ON THE UNDERWRITERS LABORATORIES LIST OF APPROVED ITEMS AND SHALL BE SIZED IN CONFORMITY WITH REQUIREMENTS OF THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND OTHER APPLICABLE CODES, WHICHEVER ARE MORE STRINGENT. C. THE WORK IS TO BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NEC AND ALL APPUCABLE FEDERAL, STATE AND LOCAL CODES. D. INCLUDE ANY LABOR AND MATERIALS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO PROVIDE A COMPLETE AND FULLY OPERATIVE ELECTRICAL SYSTEMS. PERMITS: A. SECURE AND PAY FOR ALL REQUIRED PERMITS, FEES, ASSESMENTS AND INSPECTION CERTIFICATES THAT RELATE TO THE ELECTRICAL CONTRACT. B. FURNISH APPROVED CERTIFICATE OF FINAL INSPECTION, AND TURN OVER TO OWNER AT COMPLETION OF PROJECT. DRAWINGS AND SPECIFICATIONS: A. THIS ELECTRICAL PLANS ARE DIAGRAMMATIC, NOT SHOWING EVERY ITEM IN EXACT LOCATION OR DETAIL. MEASUREMENTS AND LOCATIONS MUST BE FIELD VERIFIED AND COORDINATED WITH ARCHITECTURAL, PLUMBING, HVAC, FIRE PROTECTION, FIRE ALARM, STRUCTURAL, AND OTHER BUILDING DRAWINGS. SHOP DRAWINGS: A. SUBMIT FIVE COPIES OF MATERIAL LISTS AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE OWNER'S CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS EARLY ENOUGH IN PROJECT TO ALLOW AMPLE TIME FOR OWNER'S REVIEW WITHOUT CAUSING TIME DELAYS OR CONFUCTS IN THE JOB PROGRESS. SUBMITTALS SHALL BE IN ACCORDANCE WITH GENERAL CONDITIONS AND THE MANUFACTURERS LISTED ON THE DRAWINGS AND SHALL BEAR THE STAMP OF THE CONTRACTOR SHOWING THAT HE HAS REVIEWED AND APPROVED THEM AND THAT THEY ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS. LACK OF SUCH CONTRACTOR'S APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY THE OWNER. B. WHERE TRADE NAMES, BRANDS OF MANUFACTURERS OF EQUIPMENT OR MATERIALS ARE SHOWN ON THE DRAWINGS OR SPECIFICATIONS THE EXACT EQUIPMENT SHALL BE USED ON THE PROJECT. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL /REPLACEMENT AT THE REQUEST OF THE OWNER'S CONSTRUCTION MANAGER (AT THE ELECTRICAL CONTRACTORS EXPENSE). CONDUITS: A. CONDUIT SHALL BE STANDARD STEEL RIGID, IMC OR EMT (THIN WALL) ACCORDING TO LOCAL CODE AND LANDLORD REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FINISHED AREAS, EXCEPT AS OTHERWISE APPROVED BY ARCHITECT. EMT CONNECTIONS SHALL BE COMPRESSION OR SET SCREW TYPE. B. FLEXIBLE CONDUIT OR TYPE MC CABLE SHALL BE USED FOR FINAL CONNECTIONS TO LIGHT FIXTURES, MOTORS AND VIBRATING EQUIPMENT ONLY; AND WHERE SO USED TO BE GROUNDED WITH A SEPARATE FULL SIZED GREEN GROUNDING CONDUCTOR. FINAL TYPE MC /FLEX CONNECTIONS SHALL BE LIMITED TO 6' -0" IN LENGTH. (ARRANGE CIRCUITS SO AS TO AVOID THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILING AREAS, JUNCTION BOXES LOCATED ABOVE LAY —IN CEILINGS ARE ACCEPTABLE.) 1. MINIMUM SIZES OF CONDUITS SHALL BE 3/4" FOR STANDARD CONDUIT, AND 1/2" FOR FLEX CONDUIT (1/2" STANDARD CONDUIT AND 3/8" MC CABLE MAY BE USED AS SPECIFIED ABOVE, IF ACCEPTABLE WITH LANDLORD AND LOCAL CODES, ELECTRICAL CONTRACTOR SHALL FIELD COORDINATE WITH LANDLORD & INSPECTION AGENCIES PRIOR TO INSTALLATION). ELECTRIC METALUC TUBING (EMT) SHALL BE GALVANIZED OR ELECTRO—GALVANIZED. FITTINGS SHALL BE SET SCREW OR COMPRESSION TYPE, FITTING SHALL BE AS MANUFACTURED BY REGEL, STEEL CITY, RACO, T & B, EFCOR OR EQUAL. EMT SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS RUN ABOVE SUSPENDED CEILINGS OR CONCEALED IN INTERIOR PARTITIONS. 2. PAINTING OF ELECTRICAL CONDUITS, ETC., IF REQUIRED, WILL BE BY GENERAL CONTRACTOR. C. THE USE OF ROMEX OR BX IS NOT PERMITTED. D. MAXIMUM CONDUIT HANGER SPACING SHALL BE 8' -0" FOR 3/4" THRU 1 1/4" AND 10' -0" FOR 1 1/2" THRU 4" CONDUITS. DO NOT SUPPORT CONDUIT FROM THE CEILING SYSTEM. E. LEAVE A #10 AWG PULL WIRE OR NYLON PULL STRING IN ALL EMPTY CONDUITS. F. SECURE ALL RACEWAYS TO THE BUILDING STRUCTURE IN A RIGID AND SECURE MANNER, USING FASTENERS SUCH AS "CADDY CUPS" OR EQUAL. G. FLASH AND COUNTERFLASH ALL RACEWAYS WHICH PENETRATE THE ROOF OR USE PITCH POCKETS. INSURE THAT PENETRATIONS ARE COMPLETELY WEATHERPROOF. ALL RACEWAY SYSTEMS EXPOSED TO THE WEATHER SHALL BE WEATHERPROOF. PRIOR APPROVAL BY LANDLORD IS REQUIRED TO ADD ADDITIONAL EQUIPMENT LOADS TO STRUCTURE OR TO MAKE HOLES IN EXISTING ROOF. NOTIFY LANDLORD'S ROOFING CONTRACTOR AT LEAST 72 HOURS PRIOR TO ANY REQUIRED ROOF WORK. WIRE: A. WIRE SHALL BE SINGLE CONDUCTOR COPPER WITH 600 VOLT INSULATION. MINIMUM WIRE SIZE SHALL BE #12 AWG, ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. ALL WIRING OF ANY TYPE SHALL BE IN CONDUIT. NO STRANDED WIRE ALLOWED FOR #10 AND #12 AWG SIZES. (INCREASE CONDUCTOR BY ONE SIZE FOR EVERY 150' INCREMENT OF DISTANCE FROM THE PANEL BOARD FOR 120 VOLT CIRCUITS.) 1. GENERAL WIRING SHALL BE THW OR THHN. (ALUMINUM CONDUCTORS ARE NOT PERMITTED.) B. WIRE CONNECTORS SHALL BE EQUAL TO SCOTCHLOCK FOR #8 AND SMALLER, AND EQUAL TO T & B "LOCK -11TE" FOR #6 AND LARGER. C. THE USE OF SHARED NEUTRALS IS ACCEPTABLE FOR LIGHTING AND RECEPTACLE CIRCUITS IF INSTALLED IN ACCORDANCE WITH N.E.C. #310, AND LOCAL CODES. D. ALL WIRING TO BE COLOR CODED AS FOLLOWS: UGHTING: A. UGHTING FIXTURES AND LAMPS SHALL BE FURNISHED AS SCHEDULED ON THE UGHTING FIXTURE SCHEDULE. (THE MAJORITY OR THE FIXTURES AND LAMPS ARE FURNISHED BY THE TENANT) ELECTRICAL CONTRACTOR SHALL INSTALL ALL FIXTURES AND LAMPS. FLUORESCENT FIXTURES SHALL HAVE HPF BALLASTS WITH EFFICIENCY FACTORS IN ACCORDANCE WITH "INTERNATIONAL ENRGY CONSERVATION CODE 2001." B. LIGHT FIXTURES SHALL BE SUPPORTED FROM THE BUILDING STRUCTURAL VIA ALL THREAD AND UNI— STRUT, AND NOT SUPPORTED BY CEILING SYSTEM. WIRED GROUND SYSTEM: A. FURNISH AND INSTALL A COMPLETE WIRED GROUNDING SYSTEM FOR ELECTRICAL EQUIPMENT AND CIRCUITS AS SHOWN ON THE DRAWINGS AND DESCRIBED GENERALLY BELOW. B. ALL GROUNDING CONDUCTORS SHALL BE GREEN, WHERE EXPOSED IN PANEL, SWITCHBOARD, OUTLET, BOXES, ETC. C. ALL ENCLOSURES AND NON— CURRENT CARRYING METALS TO BE GROUNDED. CONDUIT SYSTEM TO BE ELECTRICALLY CONTINUOUS. ALL LOCK NUTS MUST CUT THROUGH ENAMELED OR PAINTED SURFACES ON ENCLOSURES. WHERE ENCLOSURES AND NON— CURRENT CARRYING METALS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS WITH APPROVED CLAMPS. D. RUN A SEPARATE GROUNDING CONDUCTOR IN EACH CONDUIT, #12 MINIMUM, OR AS SHOWN ON DRAWINGS. FOR PANEL FEEDERS BOND THE GROUNDING CONDUCTOR TO THE CONDUIT, WHERE ENTERING AND LEAVING THE CONDUIT. ALL GROUND CLAMPS SHALL BE PENN — UNION OR EQUAL, SIMILAR TO "GPL" TYPE. CONDUIT GROUND BUSHINGS SHALL BE THOMAS & BETTS OR EQUAL, SIMILAR TO #3800 SERIES WITH NYLON INSULATED THROAT. E. ALL DEVICES SHALL BE BONDED TO THE CONDUIT SYSTEM. USE A BONDING JUMPER BETWEEN THE OUTLET BOX AND THE DEVICE GROUNDING TERMINAL. METAL—TO—METAL CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX IS NOT ACCEPTABLE AS A BOND FOR EITHER SURFACE MOUNTED BOXES OR FLUSH TYPE BOXES. ALL JUNCTION BOXES, OUTLET BOXES AND PULL BOXES SHALL BE BONDED TO THE CONDUIT SYSTEM. ALL FLEXIBLE CONDUIT SHALL BE JUMPERED WITH A GROUND CONDUCTOR. WIRE DEVICES: 120/208 VOLT SYSTEM NEUTRAL — WHITE PHASE A OR L1 —BLACK PHASE B OR L2 —RED PHASE C OR L3 —BLUE GROUND —GREEN 277/480 VOLT SYSTEM NEUTRAL — WHITE WITH TRACER OR GRAY PHASE A OR L1 — BROWN PHASE B OR L2— ORANGE PHASE C OR L3 —YELLOW GROUND —GREEN WITH TRACER A. COLOR OF WIRING DEVICES AND COVERPLATES SHALL BE SELECTED BY ARCHITECT. (SEE PLAN NOTES FOR ADDITIONAL INFORMATION). 1. RECEPTACLES SHALL BE 20 AMP, 3 —WIRE GROUNDING TYPE EQUAL TO HUBBELL 5362. 2. SWITCHES SHALL BE 20 AMP SPECIFICATION GRADE, RATED AT 120 OR 277 VOLT, AS REQUIRED. 3. SPECIAL DEVICES SHALL BE A SPECIFICATION GRADE. 4. EQUAL BY ARROW —HART, GENERAL ELECTRIC, BRYANT, PASS & SEYMOUR, OR SIERRA. PANELBOARDS AND SAFETY SWITCHES: A. PROVIDE BRANCH CIRCUIT PANELS WHICH SHALL BE OF THE BOLTED CIRCUIT BREAKER TYPE WITH SOLID COPPER BUSSING FULL SIZED NEUTRAL, 25% GROUND BUSSING, OVERALL HINGED /LOCKABLE DOOR, AND TYPEWRITTEN DIRECTORY INSIDE DOOR. ALL SERVICE ENTRANCE EQUIPMENT SHALL BEAR THE MANUFACTURER'S LABEL WHICH SHALL STATE THAT THE EQUIPMENT IS RATED FOR SERVICE ENTRANCE APPLICATION IN ACCORDANCE WITH N.E.C. #230 -70. LOAD BALANCE ALL ELECTRICAL PHASES AT PANELS AND SWITCHBOARDS. TWO AND THREE POLE BREAKERS SHALL BE COMMON TRIP TYPE. WHEN USED AS SWITCHES IN 120V. AND 277V. UGHTING CIRCUITS, FURNISH TYPE "SWD" BREAKERS IN ACCORDANCE WITH N.E.C. #240 -83B. SQUARE D OR EQUAL BY SIEMENS ITE, CUTLER — HAMMER, OR GENERAL ELECTRIC (OR APPROVED EQUAL). B. PROVIDE SAFETY AND DISCONNECT SWITCHES, FUSED OR NONFUSED, AS CALLED FOR ON DRAWINGS AND AS REQUIRED BY CODE. (FUSES AS MANUFACTURED BY BUSSMAN, CHASE SHAWMUT, ECONOMY FUSE CO., OR LITTLE FUSE CO. ARE ACCEPTABLE). DISCONNECT SWITCHES THAT ARE INSTALLED AT AIR CONDITIONING EQUIPMENT, HEAT PUMPS, ETC SHALL BE FUSED IN ACCORDANCE WITH THE EQUIPMENT'S NAME PLATE REQUIREMENTS PER N.E.C. 440 -21 & 110 -3B. SWITCHES SHALL BE HEAVY DUTY, QUICK MAKE /QUICK BREAK TYPE, FUSIBLE OR NON— FUSIBLE, WEATHERPROOF AS INDICATED ON THE DRAWINGS, OR AS REQUIRED BY LOCAL CODES. LOAD AND HORSEPOWER RATED AS MANUFACTURED BY SQUARE D, SIEMENS ITE, CUTLER HAMMER, OR GENERAL ELECTRIC (OR APPROVED EQUAL). C. MANUAL MOTOR STARTERS WITH OVERLOAD PROTECTION MAY BE USED FOR FRACTIONAL HORSEPOWER MOTORS THAT DO NOT REQUIRE AUXILIARY CONTROL. SINGLE PHASE STARTERS SHALL BE SQUARE D OR EQUAL. THREE PHASE STARTERS SHALL BE PROVIDED WITH OVERLOAD DEVICE IN EACH PHASE MATCHED TO MOTOR NAMEPLATE RATING. MAGNETIC MOTOR STARTERS (MINIMUM SIZE #1) SHALL BE USED FOR ALL SINGLE PHASE AND THREE PHASE MOTORS RATED ABOVE 1/2 HP OR THAT REQUIRE AUXIUARY CONTROL. PROVIDE CONTROL DEVICES (CONTACTS, TRANSFORMERS, ETC.) IN STARTERS AS REQUIRED FOR INTERLOCKS, COORDINATE WITH MECHANICAL AND /OR TEMPERATURE CONTROL CONTRACTORS. COMBINATION STARTERS, WHEN USED, SHALL CONTAIN FUSIBLE SWITCHES. BOXES: A. OUTLET BOXES AND COVERS PRESSED STEEL KNOCKOUT. B. JUNCTION, PULL BOXES AND CODE GAUGE SIZE. C. INSTALL BOXES RIGIDLY ON BUILDING STRUCTURE AND SUPPORT INDEPENDENTLY OF THE CONDUIT SYSTEM. ALSO PROVIDE SUITABLE /PROPER BOX EXTENSIONS TO EXTEND BOXES TO FINISHED FACES OF WALLS ETC. ALL OUTLET BOXES TO HAVE SUITABLE BLOCKING BEHIND THEM TO MINIMIZE THE DEFLECTION THAT OCCURS WHEN PLUGGING /UNPLUGGING INTO THESE DEVICES. D. WHERE A 277 VOLT LIGHT SWITCH IS GANGED WITH A 120 VOLT RECEPTACLE PROVIDE A SUITABLE DIVIDER OR SEPARATE JUNCTION BOXES IN ACCORDANCE WITH NEC AND LOCAL CODES. SERVICES: SHALL BE GALVANIZED, ONE —PIECE COVERS SHALL BE GALVANIZED STEEL, A. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY SERVICE FROM LANDLORD'S DESIGNATED LOCATION AND PROVIDE LIGHTING, POWER AND WIRING AS REQUIRED TO FACIUTATE APPUCABLE TEMPORARY NEEDS, AND FURNISH EXTENSION CORDS. ANY TEMPORARY WRING, FUSES, ETC., SHALL BE REMOVED UPON COMPLETION OF THE PROJECT. PROVIDE GROUND FAULT PROTECTION AS REQUIRED BY N.E.C. AND LOCAL CODES. B. PROVIDE ELECTRICAL SERVICE AS SHOWN ON THE DRAWINGS, FIELD VERIFY EXACT REQUIREMENTS PRIOR TO BIDS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR POWER COMPANY SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE ENTIRE INSTALLATION WITH LANDLORD AND POWER COMPANY AS REQUIRED. (PROVIDE EQUIPMENT THAT IS COMPATIBLE WITH AVAILABLE FAULT CURRENT LEVELS, PROVIDE "CABLE UMITERS" IF NECESSARY FOR SYSTEM COORDINATION). FIELD VERIFY EXACT TYPE, SIZE, LOCATION, REQUIREMENTS, ETC. OF EXISTING POWER AND TELEPHONE FACILITIES PRIOR TO BIDDING PROJECT. C. MAKE PROVISIONS FOR NEW TELEPHONE SERVICE AS REQUIRED, AND AS INDICATED ON THE DRAWINGS. D. CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION WITHIN TENANT'S PREMISES SHALL BE PROVIDED AS REQUIRED FOR A COMPLETE TELEPHONE SYSTEM. OUTLET BOXES SHALL BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. CLOSELY FIELD COORDINATE WITH TENANTS CONSTRUCTION MANAGER TO AVOID CONFLICTS. STEP —DOWN TRANSFORMER: (IF APPUCABLE) A. PROVIDE DRY —TYPE TRANSFORMER AS MANUFACTURED BY SQUARE "D" , HEAVY DUTY, ACME, GENERAL ELECTRIC, SIEMENS ITE OR OTHER EQUIVALENT MANUFACTURERS, OF THE ENCLOSED VENTILATED TYPE WITH KVA AND VOLTAGE RATINGS AS CALLED FOR ON THE DRAWINGS WITH COILS DESIGNED FOR 150 DEGREE C RISE ABOVE A 40 DEGREE C AMBIENT WITH 100% OF RATED LOAD CONNECTED TO THE SECONDARY, CLASS 220 DEGREE C INSULATION AND A MINIMUM OF SIX STANDARD FULL CAPACITY TAPS (TWO ABOVE AND FOUR BELOW NORMAL). SOUND LEVEL /DECIBELS SHALL BE IN ACCORDANCE WITH "NEMA" STANDARDS, AND INSTALLATION SHALL INCLUDE "KORFOUND" OR EQUAL VIBRATION— DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY CONNECTIONS TO MINIMIZE SOUND TRANSMISSION. MOUNT TRANSFORMER ON SEPARATE VIBRATION ISOLATORS. THESE ARE ADDITIONAL VIBRATION ISOLATORS AND ARE USED IN CONJUNCTION WITH ANY INTEGRAL FACTORY INSTALLED VIBRATION ISOLATORS. LANDLORD'S NOTES: 1 ALL CABLING SHALL BE PLENUM RATED. ALL TENANTS SERVED BY LANDLORD'S AIR CONDITIONING UNIT HAVE PLENUM RETURNS. LIGHTING CONTACTOR AND TIMER SWITCHES: A. B. INSTALLATION: CONTACTORS FOR CONTROL OF LIGHTING AND SIGNS SHALL BE SQUARE "D ", CLASS 8903, TYPE "L ", ELECTRICALLY HELD. EQUIVALENT PRODUCTS BY OTHER MANUFACTURERS ARE PERMITTED. ELECTRONIC DIGITAL TIME SWITCHES SHALL BE USED FOR CONTROL OF SHOW WINDOW LIGHTING, SIGNS, AND IF REQUIRED /DESIRED OTHER LIGHTING. THE ELECTRONIC DIGITAL TIMER SHALL BE A TORK MODEL DWZ100A OR EQUIVALENT WITH A 7 —DAY FORMAT, 365 DAY ADVANCED HOLIDAY SCHEDULE, CAPABLE OF DIFFERENT SETTINGS EACH DAY OF THE WEEK, AND HAVE AN ASTRONOMIC FEATURE. A. ALL ELECTRIC WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIRING. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE FASTENED TO BUILDING STEEL, CONCRETE OR MASONRY, BUT NOT PIPING OR DUCTWORK. ALL CONDUIT SHALL BE CONCEALED WHEREVER POSSIBLE. EXPOSED CONDUITS SHALL BE IN STRAIGHT ONES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES OR BEAMS AND SEPARATED AT LEAST 3 INCHES FROM WATER LINES WHEREVER THEY RUN ALONGSIDE OR ACROSS SUCH UNES. ALL CONDUCTORS SHALL BE IN CONDUIT, DUCTS OR OTHER CODE APPROVED RACEWAYS. B. ALL LINE AND LOW VOLTAGE POWER AND CONTROL WIRING (EXCEPT HVAC LOW VOLTAGE WIRING) INCLUDING CONNECTIONS TO MOTORS, DAMPERS, INTERLOCKING, ETC., SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. (ALL LINE VOLTAGE WIRING, CONDUIT, AND FINAL CONNECTIONS FROM THE POWER SOURCE THRU THE STARTER /DISCONNECT ETC. TO THE MOTOR OR EQUIPMENT IS THE RESPONSIBILITY OR THE ELECTRICAL CONTRACTOR. ALL HVAC RELATED LOW VOLTAGE CONTROL WIRING, CONDUIT AND FINAL CONNECTIONS IS THE RESPONSIBILITY OF THE MECHANICAL /TEMPERATURE CONTROL CONTRACTOR, UNLESS OTHERWISE NOTED ON THE PLANS). C. THE ELECTRICAL CONTRACTOR SHALL DO ALL CUTTING, CHASING OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK UNDER THE ELECTRICAL DIVISION, ANY CUTTING SHALL HAVE PRIOR APPROVAL OF THE LANDLORD. SLEEVES SHALL EXTEND AT LEAST TWO (2 ") INCHES ABOVE FINISHED FLOOR AND ALL SLEEVES, OPENINGS, ETC., THROUGH FIRE RATED WALLS AND FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL BY HIL11 AFTER CONDUIT /CABLES INSTALLATION SO AS TO RETAIN THE FIRE RATING. D. THE ELECTRICAL CONTRACTORS, INSOFAR AS THE WORK IS CONCERNED, SHALL AT ALL TIMES KEEP THE PREMISES IN A NEAT AND ORDERLY CONDITION AND, AT THE COMPLETION OF THE WORK, SHALL PROPERLY CLEAN UP AND CART AWAY ANY DEBRIS AND EXCESS MATERIAL. E. THE FOLLOWING EQUIPMENT SHALL BE IDENTIFIED WITH ENGRAVED BAKELITE NAMEPLATES AS TO NAME AND /OR FUNCTION; DISTRIBUTION PANELS, LIGHTING PANELS, MOTOR STARTERS AND DISCONNECT SWITCHES. NAMEPLATES TO BE APPROXIMATELY 1" X 2" IN SIZE AND BE FASTENED WITH POP RIVETS OR SCREWS. F. THE LOCATION OF OUTLETS AND EQUIPMENT SHOWN ON THE DRAWINGS ARE APPROXIMATE AND THE ARCHITECT /TENANT CONSTRUCTION MANAGER SHALL HAVE THE RIGHT TO RELOCATE ANY OUTLETS OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. G. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN THE WORK AS THE JOB PROGRESSES, AND TURN THIS "AS BUILT" INFORMATION OVER TO THE OWNER AT THE COMPLETION OF THE PROJECT. H. ELECTRICAL CONTRACTOR SHALL PROTECT ALL FIXTURES /EQUIPMENT AGAINST DAMAGE FROM LEAKS, ABUSE, ETC., AND PAY COST OF REPAIR OR REPLACEMENT OF FIXTURES OR EQUIPMENT MADE NECESSARY BY FAILURE TO PROVIDE SUITABLE SAFEGUARDS OR PROTECTION. I. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. AFTER ALL EQUIPMENT HAS BEEN INSPECTED AND APPROVED, THOROUGHLY CLEAN ALL EQUIPMENT PROVIDED UNDER THIS WORK JUST PRIOR TO COMPLETION OF PROJECT. J. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ANY /ALL NECESSARY ELECTRICAL DEMOLITION WORK THAT IS REQUIRED TO FACILITATE THE NEW INSTALLATION, FIELD COORDINATE PRIOR TO BIDS. REMOVE AND /OR MODIFY EQUIPMENT, ETC. AS REQUIRED FOR A COMPLETE INSTALLATION. ANY EQUIPMENT OR DEVICE REMAINING IN USE AFTER PART OF THE EQUIPMENT OR DEVICES HAVE BEEN REMOVED ARE TO BE RECONNECTED TO EXISTING OR NEW CIRCUITS AND LEFT IN WORKING ORDER. FEEDERS TO PANELS AND WIRING TO OTHER EQUIPMENT TO BE ROUTED CONCEALED IN FINISHED AREAS. COORDINATE ANY DISRUPTION OF ELECTRICAL OR TELEPHONE SERVICES WITH LANDLORD AND TENANT CONSTRUCTION MANAGER TO AVOID CONFLICTS. GUARANTEE: A. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THE ELECTRICAL CONTRACTOR'S EXPENSE. B. FOR THE SAME PERIOD, ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND /OR INSTALLED BY THE ELECTRICAL CONTRACTOR. FINALLY: A. IT IS THE INTENT THAT THE FOREGOING WORK SHALL BE COMPLETE IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. REVIEWED F O R CODE COMPLIANCE EC NFPA NOV 2 C • �l�y flf Tukwila B ILDING DIVISION AREA: TSAO REVIEWED BY: SHEET NO. FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 Nrr PROJECT LOCATION: 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesign.com Embank, On lnea M• Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 RMJ Robinson M eie r Juilly & Associates www.rmjse.com RMJ Job No.: 07186 GON JOB 0712121 Structural Engineers 103 Linden Avenue So. San Francisco, CA 94080 Tel: 650.871.2282 Fax 650.8712459 13 4.2 35495 IONAL h =rs 07 / t OCT 042007 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 981 18 E6.0 5,439 SF DEG 5 5 4 4 I 1 3 3 2 2 1 1 SHEET TITLE: ELECTRICAL SPECIFICATIO\S PROJECT NO. 0744.03 SCALE: DATE: DRAWN BY: CITY OF _ t J � NONE E+F- i- e'i.4.i• r+ - -•.• • • v�1V1�C( 10 -08-07 FJM D C B