Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL07-585 - VERIZON WIRELESS
VERIZON WIRELESS 17100 SOUTHCENTER PY STE 116 EL07-585 Parcel No.: 2623049081 Address: 17100 SOUTHCENTER PY TUKW Suite No: DESCRIPTION OF WORK: ELECTRICAL FOR NEW TI Value of Electrical: $22,400.00 Type of Fire Protection: SPRINKLERS Permit Center Authorized Signature: Signature: Print Name: doc: EL -4/07 Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Tenant: Name: VERIZON WIRELESS Address: 17100 SOUTHCENTER PY, STE 116 , TUKWILA WA ELECTRICAL PERMIT Owner: Name: WIG PROPERTIES LLC -SS Phone: Address: 4811 134Th PL SE , BELLEVUE WA Contact Person: Name: DERRICK PRODIGALIDAD Phone: 818 786 -8960 Address: 13648 BURBANK , SHERMAN OAKS CA Contractor: Name: GSB ELECTRIC INC Phone: 360 652 -3840 Address: 16531 80 AV NW , STANWOOD WA Contractor License No: GSBELEI955L3 Expiration Date: 06/23/2009 Electrical Service provided by: PUGET SOUND ENERGY at c6,ve Permit Number: EL07 -585 Issue Date: 12/17/2007 Permit Expires On: 06/14/2008 Fees Collected: National Electrical Code Edition: $574.00 2005 Date: `© 7 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the erfonna of wo I = _. autthh d to sign and obtain this electrical permit. / sue® Date: / 617 Gre This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. EL07 -585 Printed: 12 -17 -2007 Parcel No.: 2623049081 Address: Suite No: Tenant: 1: ** *ELECTRICAL * ** Print Name: doc: Cond - Elec 17100 SOUTHCENTER PY TUICW VERIZON WIRELESS City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us g4c /LP // PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL07 -585 ISSUED 10/15/2007 12/17/2007 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: ' 8/°' Date: / ?- /7 O7 EL07 -585 Printed: 12 -17 -2007 �1 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://wwwci.tukwila.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 1 I ( D Sa■Ak ti .t/dCle-A__ Tenant Name: Q/ViMv U1JN Property Owners Name: N7A Mailing Address: State Zip Name: 'e ♦il wit I. Mailing Address: (3 (0 4S ov& 11 E -Mail Address: A (‘dab ELECTRICAL CONTRACTOR INFORMATION Puget Sound Energy ❑ Seattle City Light H:Upplications\Forrns- Application On Line44-2007 - Electrical Permit Applicetion.doc bh Electrical Permit No. Project No. - (For office use only) V King Co Assessor's Tax No.: Suite Number: t t F oor: Yes ❑..No City CONTACT PERSON - Who do we contact when your permit is ready to be issued New Tenant: Day Telephone:' 1IC�" eve c City State Zip Fax Number: Company Name: Mailing Address: ^ O City State Zip Contact Person: Day Telephone. E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ 4bV J / ,� Scope of Work (please provide etailed information): IG /� I� r 5/0/2W G /e � A r 3Q0 SQ FT ?� a f ro Will service be altered? ❑ Yes ISS No Adding more than 50 amps? ❑ Yes J No Type of Use: Type of work: New ❑ Addition ❑ Service Change ❑ Remodel .J Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: Page 1 of 2 I Date Application Accepted: RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: L _ Print Name: 15� �� /Y -1/ Mailing Address: 37/36 23rd Pi 10(tCivi H;Apphcations\Forms-Applicattons On Line4-2007 - Electrical Permit Application.doc bh $140.00 $75.00 ea $55.00 ea Date Application Expires: MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Day Telephone: aP S 3 G77 k.74' Fe/.val woi wit leas �y State z, City state Zip ty ii D Date: / /D 7 Staff Initials: /� I Page 2 of 2 City of Tukwila Parcel No.: 2623049081 Address: 17100 SOUTHCENTER PY TUKW Suite No: Applicant: VERIZON WIRELESS Receipt No.: R07 -02772 Initials: WER User ID: 1655 Payee: GSB ELECTRIC doc: Receiot -06 Payment Check 5087 ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT TRANSACTION LIST: Type Method Description Amount Account Code Current Pmts 000.322.101.00.0 459.20 Total: $459.20 Permit Number: EL07 -585 Status: APPROVED Applied Date: 10/15/2007 Issue Date: Payment Amount: $459.20 Payment Date: 12/17/2007 11:38 AM Balance: $0.00 459.20 6121 12/11 9710 TOTAL 459.20 Printed: 12 -17 -2007 RECEIPT NO: R07 -02249 Initials: User ID: 1165 Payee: PERMIT PLACE SET ID: S000000877 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http. //www.ci.tukwila.wa.us D07 -387 704.87 EL07 -585 114.80 M07 -221 57.14 PG07 -275 37.00 TOTAL: 913.81 TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT Payment Date: 10/15/2007 Total Payment: 913.81 Amount Payment Check 6105 913.81 TOTAL: 913.81 Account Code Current Pmts 000.345.832.00.0 114.80 000/345.830 799.01 TOTAL: 913.81 P V / U/ " I Gi � S Type o � / on / 7U0 2.... ` Address: 1?Hm tf � W��� -4� Date Called: S pecial Instructions: Date Wanted: /iXi G..na! P.m. Requester: Phone No: fc n - 7 - Se INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 9- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36i'0 INSPECTION RECORD Retain a copy with permit roved per applicable codes. n Corrections required prior to approval. COMMENTS: -- f /N,9 17 6f- 5A621/6 IDate: 2//1/h1" $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Proyest. /56N i4/0 [/ KS '( Type of Inspection: 70 Address: 7 /aV c01./ j,s/7 4 / Date Called: Special Instructions: Date Wanted: if . . m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD 1 Retain a copy with permit V 7 — J F T PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 I pproved per applicable codes. El Corrections required prior to approval. COMMENTS: /)/) CL / - /4,' -- CL/ 4i i - pZ /i c/ ( W6//7 Ar--6,442e6 Inspe 3 6,,i-r-414X/0/ (Date: ,//k r El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Project: Vi 12ON 0 I R FI. V Type of Inspection: 00 1 Address: I '710 0 _ ul H ervrmc PAO Date Called: 1 0 6 Special Instructions: Date Wanted: ) — /y- Ue 9 a.m. p.m. Requester: 9 999 Phone No: ■ x/73 .33i3 1 /4 /9 y INSPECTION NO. t INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: D IC .5LA \z5 /L 'Inspect Date: Y y� N r � I- /`l- 08 $58.0 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Project: lie4/ 2 o Ai Type of Inspection: Address: P /CFO .. "2! CeAta4 AVY Date Called: Special Instructions: Date Wanted: /247 Cirri,. Pak Requester: Phone No: fi-o7-.Cari INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 OMMENTS: it () / 9 (K - c49(14, proved per applicable codes. El Corrections required prior to approval. Inspen IDate /2-4eA7 El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project Info Project Address SOUTH CENTER SQUARE Date 9/24/2007 17100 SOUTH CENTER PARKWAY, SUITE 116 For Building Department Use TUKWILA, WA 98188 Applicant Name: VERIZON WIRELESS Applicant Address: Applicant Phone: 2006 Washington State Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM 2008 Washington State Nonresidential Energy Code Compliance Forms REVIEWED FOR CODE COMPLIANCE NFPA70 -NEC NOV 2 6 1007 kLz its Of Tukwila BUILDING DIVISION FILE COPY EXE 12 /08/08 Revised July 2007 RECEIVED CITY OF TUKWIIA OCT 1 5 7007 PEhIVII I CENTER wiCic Fan Equipment Schedule . • Equip. ID Brand Name' Brand Name'. Capacity Btu/h Model No. CFM SP' HP /BHP Flow Control Location of Service IF -1 COOK VERIZON WIRELESS 60 ACES 200 0.50 0.25 CV REST ROOMS DFO78 2210 YES 10.4 EER 96 ROOF Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu/h Total CFM OSA CFM or Econo? SEER or EER IPLV Location RTU -1 YORE DF090 VERIZON WIRELESS 2550 YES 10.4 EER 96 ROOF RTU -2 YORK DFO78 2210 YES 10.4 EER 96 ROOF Heating Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu/h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency RTU - 1 YORK D7090 VERIZON WIRELESS 2550 YES 120 96 0.800 RTU - 2 YORK 01078 2210 YES 120 96 0.800 Project Info Project Address SOUTH CENTER SQUARE Date 9/24/2007 17100 SOUTH CENTER PARKWAY, SUITE 116 For Building Dept. Use TUKWILA, WA 98188 Applicant Name: VERIZON WIRELESS Applicant Address: Applicant Phone: 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. ❑ Includes Plans Include documentation requiring compliance with commissioning requirements, Section 1416. Revised July 2007 Compliance Option ® Simple System 0 Complex System O Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 'If available. 2 As tested according to Table 14-1A through 14-1G. 3 1f required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: 5 Constant vol? Split system? 0 Air cooled? . Packaged sys? 0 <20,000 Btuh? Economizer included? • 1S1 If Heating Only: II <5000 cfm? U <70% outside air? Mechanical Summary (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only 2006 Washington State Nonresidential Energy Code Compliance Form C ■ Reference Section 1421 J Heating /Cooling or Cooling Only Yes Simple System Allowed (section 1420) Yes — Yes". otal Ca •. wo economize <240,000 Btuh r 10 %? Yes Yes • Reference Section 1423 Yes No► • Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical Permit Plans Checklist 2008 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised July 2007 Project Address SOUTH CENTER SQUARE IDate 9/24/2007 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component • Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n. a 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency Ma n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket Toss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans Mi yes 1412.2 Deadband control Indicate 5 degree deadband minimum M3 n • a • 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 dill. day types M3 yes 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage M2 -M3 n • a • 1412.4.2 Optimum Start Indicate optimum start controls n • a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule yes 1412.6 Combustion htg. Indicate modulating or staged control M2 yes 1412.7 Balancing Indicate balancing features on plans Mi 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas yes 1422 Thermostat Interlock Indicate thermostat Interlock on plans M3 yes 1423 Economizers Equipment schedule 242 1413 Air economizers yes 1413.1 Air Econo Operation Indicate 100% capability on schedule M2 n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance yes 1413.3 Integrated operation Indicate capability for partial cooling M3 n.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary M3 yes 1414.2 Duct insulation Indicate R -value of insulation on duct M3 n.a. 1415.1 Piping insulation Indicate R -value of Insulation on piping 1416 Completion Requirements yea 1416.2.1 Commissioning Provide commissioning plan M3 yes 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing Ml yes 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training M3 yea 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report • M3 M.A. 1434 Separate air sys. Indicate separate systems on plans . yea I Mechanical 'Completed and attached. Equipment schedule with types, Summary Form input/output, efficiency, cfm,•hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. yes 1441 Elec. water heater Indicate R -10 Insulation under tank P2 1442 Shut -off controls Indicate automatic shut -off yes 1443 Pipe Insulation Indicate R -value of insulation on piping 123 M.A. 1452 Heat Pump COP Indicate minimum COP of 4.0 n. a. 1452 Heater Efficiency Indicate pool heater efficiency n.a. 1453 Pool heater controls Indicate switch and 65 degree control n.a. 1454 Pool covers Indicate vapor retardant cover n. a. 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable altemative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be fumished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 • Packa equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F Inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system Is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power Toss of 10 hours and Include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon Toss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories In height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings 1412.8 Ventilation Controls for High - Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is Tess than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and Internal load shall be the same as those used for peak Toad calculations,' except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following inform ation: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling Is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economiser. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which Is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 Inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seat all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with Tess than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage • 0.55. 0.70 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable altemative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be fumished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 • Packa equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F Inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system Is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power Toss of 10 hours and Include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon Toss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories In height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings 1412.8 Ventilation Controls for High - Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is Tess than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and Internal load shall be the same as those used for peak Toad calculations,' except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following inform ation: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling Is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economiser. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which Is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 Inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seat all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with Tess than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, Project Info Project Address SOUTH CENTER SQUARE Date 10/10/2007 17100 SOUTH CENTER PARKWAY SUITE 116 For Building Department Use TUKWILA, WA 98188 Applicant Name: HENDERSON ENGINEERS Applicant Address: 8325 LENEXA DR. SUITE 400, LENEXA ES 66214 Applicant Phone: (913) 742 -5000 Project Description BACK ARIA ❑ Plans Included requirements. ❑ New Building • Addition 12 Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, Installed wattage not increased, & space use not changed. Location (floor /room no.) Occupancy Description Allowed Watts per ft ** Area in ft Allowed x Area SALES /SERVICE Retail Sales Floor 1.50 2351.0 3526.5 BACK ARIA Office /Support Area 1.00 946.0 946.0 SALES /SERVICE Additional 1.5W /SF for Retail Display (Foot Not. 10) 1.50 2351.0 3526.5 ** From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 7999.0 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed BALKS /sZRVICE •7 6 DOWNLIGHT 63 36.0 2268.0 •G• 6• DOWNLIGHT WITH EM. BALLAST 12 36.0 432.0 •Q• SALES DESKS DOWNLIGHT - 6 29.0 174.0 ■E■ DEMO BAR PENDANT 2 90.0 180.0 •N■ TRACK LIGHT 18 50.0 900.0 •NN• TRACK LIGHT 2 80.0 160.0 'NC' MONOPOINT TRACK LIGHT 5 50.0 250.0 •U• UNDERCABINKT FIXTURE 1 19.0 19.0 •H• PHONE TABLE PENDANT 4 80.0 320.0 •C■ RECESSED 2x4 7 91.0 637.0 •D• RECESSED 2x4 WITH EM. BALLAST 4 91.0 364.0 'CS' SURFACE MOUNT 2x4 . 3 91.0 273.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 5977.0 Interior Lighting Summary LTG -INT 2008 Washington State Nonresidential Energy Code Compliance Forms Maximum Allowed Lighting Wattage Proposed Lighting Wattage 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if Included). For track lighting, list the length of the track (in feet) In addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fbxture, use manufacturer's listed maximum Input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. Use' LPA` (W /sf) Use' LPA (N/ /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches) ' i ' 1.0 Convention center 1.2 Penitentiary and other Group 1-3 Occupancies 1.0 Courthouse 1.2 Police and fire stations 1.0 Cafeterias, fast food establishments', restaurants/bars' 1.3 Post office 1.1 Dormitory 1.0 Retail retail banking, mall concourses, wholesale stores (pallet rack sheMnq) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia', assembly spaces' 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet /conference /exhibition hall''' 2.0 Workshops 1.4 Laboratory spaces (all spaces not classed "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: Q Warehouses, storage areas or aircraft storage hangers Q Other Q ualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) ❑ Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts 3. LED lights. Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms 5 -1 Unit Lighting Power Allowance (LPA ootnotes for Table 15- 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w/ft may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter -height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w/ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually. installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address SOUTH CENTER SQUARE IDate 10/10/2007 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations yes 1513.2 Area controls Maximum limit per switch yea 1513.3 Daylight zone control Schedule with type and features, indicate locations vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location yea (a) timer w/backup Indicate location n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location • yes 1513.6.1 (a) occup. sensors Schedule with type and locations yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans n.a. 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes I 1514 I Max. watts 'Indicate watts for each exit sign I LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting • Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture n.a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fodure MOTORS (Section 1511) yes I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I TRANSFORMERS (Section 1540) n.a. I 1540 (Transformers 'Indicate size and efficiency 2UUb Washington state Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: L uut wasnln ton State Nonresidential Ener• Code Com • liance Form Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1613.2Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which Is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant - sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.6 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk-to-dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall . be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of turning off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which turns off all Toads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft or 5% of the building footprint for footprints over 100,000 ft2, whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP -1- 2002). October 24, 2007 Derrick Prodigalidad 13648 Burbank Sherman Oaks, CA 91401 RE: CORRECTION LETTER #1 Electrical Permit Application Number EL07 -585 Verizon Wireless —17100 Southcenter Py, Ste 116 Dear Mr. Prodigalidad, This letter is to inform you of corrections that must be addressed before your electrical permit can be approved. All correction requests from the Building Department must be addressed and reflected on your drawings. Building Department: Bill Buterbaugh, at 206 973 -4758, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that three (3) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, encl arshall chnician xc: File No. EL07 -585 Cizy of Tukwlla P:\Pemrit Center\Correction Letters \20071ELO7 -585 Correction Ltr #1.DOC jem Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6. 700 .Sn»thrpnter Rnulevard_ Suite #100 • Tukwila. Washington 08188 • Phone: 206 -431 -3670 • Fax: 206- 431 -3665 1 Date: August 23, 2007 Project Name: Verizon Wireless Permit #: EL07 -585 Plan Reviewer. Bill Buterbaugh 2. Panel designations are L -116 and L -116 -A Building Division Review Memo 1. Per approved landlord plans (permit EL07 -422) there are 2 roof top units - they are rated at 15780VA per unit (5260VA per phase). Please revise panel schedules and load calculations. Note: Egress path requires 1 foot candle at floor along the entire pathway and egress discharge area. ACTIVITY NUMBER: EL07 - 585 DATE: 11 -14 -07 PROJECT NAME: VERIZON WIRELESS SITE ADDRESS: 17100 SOUTHCENTER PY STE 116 Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEEP�AjRT,M�'E�NTS: iO41 Building ©Msio Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -15 -07 Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2 -28-02 COPY PLAN P �� M V I EW /R OUTING SLIP Fire Prevention Incomplete ❑ Structural Review Required REVIEWER'S INITIALS: Planning Division Not Applicable ❑ No further Review Required El DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12 -13 -07 Approved ❑ Approved with Conditions II Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY L, PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL07 -585 DATE: 10 -15 -07 PROJECT NAME: VERIZON WIRELESS SITE ADDRESS: 17100 SOUTHCENTER PY, STE 116 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building Alan Public Works Complete Comments: Documents/routing slip.doc 2 -28-02 ; 2.01 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) APPROVALS OR CORRECTIONS: Fire Prevention Structural Incomplete n TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ Permit Coordinator ❑ DUE DATE: 10-1 6-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: Planning Division Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 1'1 Fire ❑ Ping ❑ PW ❑ Staff Initials: n DUE DATE: 11-13-07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www,ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 11 0 Plan Check/Permit Number: EL07 -585 ❑ Response to Incomplete Letter # Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Verizon Wireless Project Address: 17100 Southcenter Py, Ste 116 Contact Person: j t c y t a c 9 x v A , A r 7 1 o Phone Number: Slfs • l5 (o • S-t (o C 1 Summary of Revision: - 'ftvrt n•NY4 k ir107 LnAv Cprt - SEE J 11 - e •?> VeSIArJ?mCA Lllb tr,'O L-1 h. -A E.1, 6.2- -S 6 -y Sheet Number(s): "Cloud" or highlight all areas of revision including date o revision Received at the City of Tukwila Permit Center by: '- - Entered in Permits Plus on 11 ` --vo \applications \forms - applications on line\revision submittal Created: 8 -13 -2004 Revised: Steven M. Mullet, Mayor Steve Lancaster, Director RECEIVED art OF TUKWILA NOV 1420011 Business Owner Information Name Role Effective Date Expiration Date BLACKWELL, GREG T AGENT 06/23/2005 BLACKWELL, GREG T PRESIDENT 06/23/2005 BLACKWELL, Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 ftelo Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License Licensee Name Licensee Type UBI Ind. Ins. Account Id Business Type Address 1 Address 2 City County State Zip Phone Status Specialty 1 Specialty 2 Effective Date Expiration Date Suspend Date Separation Date Parent Company Previous License Next License Associated License GSBELEI955L3 GSB ELECTRIC INC ELECTRICAL CONTRACTOR 602468640 6838501 CORPORATION 16531 80TH AVE NW STANWOOD SNOHOMISH WA 98292 3606523840 ACTIVE GENERAL UNUSED 6/23/2005 6/23/2009 GSBELE *963LT BLACKGT968LT Electrical Administrator Information License Name Status BLACKGT968LT BLACKWELL, GREG T ACTIVE https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= GSBELEI955L3 12/17/2007 29 INVENT(; Loo WP /GFc 1 PA: L- 1-61-A TI C2 C1 r 10 116 ---A L -116 POWER FOR HVAC UNIT NZ UNIT ABOVE DOOR •Y 22 L -116 20 L -116 -A GFCI L -116 E3R1_,�K AHF A 32 I3ACK AkLA I ilf{ 1 POWER AND DATA FOR SECURITY SECURITY PANELS SECURITY EQUIPMENT, BOTTOM OF SHELF 0 - W US. TELCO ROOM PLAN NOT TO SCALE 1 1 32 1 1 '21 L -116 16 -A 1 107 12' LONG GROUNDING BAR 0 z 6' AFF 0 TELEPHONE COMM 4'-0' LONG, 4' 4 SLEEVE WIIH BUSHINGS QUAD OUTLET ® +18" AF.F. 30 AMP TWIST LOCI( OUTLET 0 +18' AFF. (NEM 15 -30R) CABLE TRAY ABOVE TacO RACK 28 L -116 POWER FOR TN STORE MUSIC +70' AFF. IN STORE MUSIC SiSTEII 0 +6O" AFF. 2" 4 TELEPHONE CONDUIT TO MAIN POINT OF ENTRY WITH PULL 5N(NG (-0' LONG 4 0 SLEEVE WITH BUSHINGS CABLE TRAY ABOVE TELEPHONE PAGING SYSTEM ON WALL BEYOND TELCO RACK If LONG GROUNDING FAR 0 +36' AFF TELCO ROOM ELEVATION NOT TO SCALE L-- 16 1 mAh1ACCE t 29 L -116 SECURITY LM BOTTOM 0 +86" AFF. SECURITY PANELS 4'-0" LONG 4' 0 SLEEVE BUSHINGS TELEPHONE PAC= CABLE TRAY ABOVE TELCO RACK 30 AMP TWIST LOCK +18" AFF. (NEMA 15 -30R) QUAD OUTLET 0 +18' AFF. UPS ON FLOOR r -I 1R' 27 L -116 L .. 1 1 �`? 74" SKEWED (TYP) L -116 17(PART) L -116 L -116 23 14 12 116=A t 30 /2 /NF L -116 3(PART) 4(PART) t L -116 C TELCO ROOM ELEVATION NOT TO SCALE f-11/2• CI,1ST@iV . R'lf n: - - 7 TELCO ROOM ELEVATION NOT TO SCALE TELCO ROOM ELEVATION NOT TO SCALE L -116 POWER FOR HVAC UNIT 0 99' A.F.F. HVAC UNIT ABOVE DOOR }VAC PUMP SECURITY MR BOTTOM 0 +86' POWER AFF. SECURITY PANELS l L -116 - 5 POWER PLAN SCALE: 1/4"- L-116 1 11 4 7 8 161 9 1(PART) L -116 2(PART) L -116 1, Mk MMEI 'r► Mrr 11+ . L -116 t I L-116 38 421 40 WP /GFC ELECTRICAL PLAN NOTES: POWER RECEPTACLE FOR VZTV. GENERAL ELECTRICAL NOTES: / • L -116 18 f~v COPY/FAX _' 1. PROVIDE A CODE SIZE GREEN EQUIPMENT GROUNDING CONDUCTOR FOR ALL LINE VOLTAGE CIRCUITS. 2. PROVIDE BACK BOXES WITH 1/2" CONDUIT STUBBED TO ABOVE CEILING WITH BUSHING FOR ALL WALL - MOUNTED HVAC CONTROLLERS. REFER TO MECHANICAL DRAWINGS FOR LOCATIONS. 3. ELECTRICAL CONTRACTOR SHALL COORDINATE PLACEMENT OF POWER AND DATA OUTLETS WITH CABINET CONTRACTOR IN ORDER THAT THEY ARE CENTERED INSIDE LOWER CABINETS. ROUTE CIRCUIT THROUGH CONTACTOR "Cl" AND CONTROL VIA TIMESWITCH "TI ". REFER TO DETAIL 3 AND CONTACTOR SCHEDULE ON SHEET E4. 20 -A RECEPTACLE, FLUSH IN CEILING, ABOVE STORE WINDOW, FOR HANGING FUTURE POWERED DISPLAY UNITS. COORDINATE EXACT LOCATION WITH ARCHITECT. L11 WALKER 880 OMNIBOX SERIES TWO -GANG CAST IRON FLOOR BOX FOR (1) FLUSH DUPLEX RECEPTACLE AND (4) FLUSH CATEGORY 5 COMMUNICATION JACKS FOR PHONE TABLE. REFER TO DETAILS 7 AND 13 /SHEET E5. FLOORBOX - #880CS2 COVER PLATE FLANGE = #827TCAL (BLACK) DUPLEX COVER PLATE _ #828R -TCAL (BLACK) COMMUNICATION COVER PLATE - #829PSTC -BLK (BLACK) COVER PLATES SHALL BE FLUSH WITH FLOORING. PROVIDE (1) 1" CONDUIT, WITH PULL STRINGS FOR POWER AND (1) 1-- 1/2" CONDUIT, WITH PULL STRING FOR DATA. ROUTE CONDUITS UNDER SLAB. STUB DATA UP IN WALL TO 6" ABOVE CEILING LINE. PROVIDE WITH END BUSHING. REFER TO DETAIL 5 /SHEET E5. WALKER 880 OMNIBOX SERIES THREE -GANG CAST IRON FLOOR BOX WITH (2) DUPLEX RECEPTACLES AND (1) OPEN BOX (NO COVER) FOR DATA PULL FOR DEMO BAR. REFER TO DETAILS 7 AND 15 /SHEET E5. FLOORBOX = #880053 COVER PLATE FLANGE - #837TCAL (BLACK) DUPLEX COVER PLATE = #828R -TCAL (BLACK), TYP. OF 2 COMMUNICATION COVER PLATE _ #829CKTCAL -1 (BLACK) COVER PLATES SHALL BE FLUSH WITH FLOORING. PROVIDE (1) 1" CONDUIT, WITH PULL STRINGS FOR POWER AND (1) 2" CONDUIT FOR DATA ROUTE CONDUITS UNDER SLAB. STUB DATA UP IN WALL TO 6" ABOVE CEILING UNE. PROVIDE WITH END BUSHING. ROUTE (1) 1" CONDUIT FOR SECURITY VENDOR FROM OUTLET BOX ON WALL, INSIDE CABINET TO ABOVE CEILING. REFER TO DETAIL 5 /SHEET E5. WALKER 880 OMNIBOX SERIES TWO -GANG CAST IRON FLOOR BOX FOR (1) AMP #557652-1 16" LINE ENTRY CABLE AND (1) OPEN BOX FOR DATA PULL FOR FREESTANDING POS. REFER TO DETAIL 7 /SHEET E5. FLOORBOX = #880CS2 COVER PLATE FLANGE = #827TCAL (BLACK) POWER COVER PLATE - 829CKTTCAL -1 (BLACK) COMMUNICATION COVER PLATE - #829CKTTCAL -1 (BLACK) COVER PLATES SHALL BE FLUSH WITH FLOORING. L-116 6(PART) d ' u L -116 1(PART) L -116 m 15 16 m 18 19 Eta 24 RI:.TAIE. '..3ALES q 9 , _`( - .. i1► 11► 2(PART) L -116 - -2 - - L -116 3(PART) L -116 4(PART) _ . _ 4- - -- REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division, N 1-7: Revisions will require a new plan submittal • r ly include additional plan review flees ` 7 ( ` 7 r L -116 5(PART) 10 L -116 L -116 6(PART) 10 WALKER 880 OMNIBOX SERIES THREE -GANG CAST IRON FLOOR BOX WITH (2) 25 DUPLEX RECEPTACLES AND (4) CATEGORY 5 COMMUNICATION JACKS FOR CUSTOMER CHECK -IN FIXTURE. REFER TO DETAIL 7 AND 14 /SHEET E5. 26 FLOORBOX = #880CS3 COVER PLATE FLANGE = #837TCAL (BLACK) DUPLEX COVER PLATE _ #828R —TCAL (BLACK), TYP. OF 2 COMMUNICATION COVER PLATE = #829PSTC —BLK (BLACK) COVER PLATES SHALL BE FLUSH WITH FLOORING. PROVIDE DUCT DETECTORS IN SUPPLY AND RETURN DUCTS FOR MECHANICAL EQUIPMENT UNLESS EXISTING. PROVIDE REMOTE TEST STATION AND AUDIO VISUAL DEVICE WITH KEYED RESET UNLESS EXISTING. COORDINATE EXACT LOCATION WITH OWNER'S REPRESENTATIVE. WP /GFCI RECEPTACLE AT RTU. PROVIDE IF NOT EXISTING. 13 REFER TO EQUIPMENT SCHEDULE ON SHEET M2 FOR DISCONNECT. R. POWER SUPPLY FOR CONTINUOUS PLUGMOLD STRIP. LOAD CALCULATED AS 180VA /5LF PER CODE. REFER TO DETAIL 3 /SHEET E5. AMP MODULAR POWER RECEPTACLES PROVIDED AND INSTALLED BY CASEWORK MANUFACTURER. DATA WIRING BY VERIZON WIRELESS. PROVIDE JUNCTION BOX AND AMP #557652 -1 16" LINE ENTRY CABLE FOR MANUFACTURED WIRING SYSTEM FEED. REFER TO DETAIL 1 /SHEET E5. PARTS TO BE ORDERED FROM WEIDENBACK -BROWN ALONG WITH LICHT FIXTURES. REFER TO GENERAL LIGHTING NOTES 5 AND 6 /SHEET E2. PROVIDE JUNCTION BOX AND AMP #557652 -3 96" LINE ENTRY CABLE FOR MANUFACTURED WIRING SYSTEM FEED. REFER TO DETAIL 2 /SHEET E5. PARTS TO BE ORDERED FROM WEIDENBACK -BROWN ALONG WITH LIGHT FIXTURES. REFER TO GENERAL LIGHTING NOTES 5 AND 6 /SHEET E2. PROVIDE (1) 2" CONDUIT FOR DATA. ROUTE CONDUIT AND POWER FEED THROUGH ADA UNDER COUNTER COMPARTMENT. STUB DATA UP IN WALL TO 6" ABOVE CEILING LINE. PROVIDE WITH END BUSHING. COORDINATE WITH CASEWORK PROVIDER. RE: DETAIL 2 /SHEET E5. 20 DUPLEX RECEPTACLE AND SINGLE GANG J -BOX WITH BLANK COVER, 3/4" CONDUIT TO 6" ABOVE CEILING, AND END BUSHING. INSTALL 8" BELOW CEILING FOR SECURITY MONITOR CONNECTIONS. 3/4" FIRE RATED, PAINTED CDX PLYWOOD TELEPHONE EQUIPMENT BOARD FLOOR TO CEILING ON ALL WALLS. COORDINATE EXACT LOCATION WITH VERIZON WIRELESS. 22 4' -0" LONG, 4" CONDUIT WITH BUSHINGS AT EACH END. CONDUIT SHALL EXTEND 2' -0" ABOVE AND BELOW CEILING. PROVIDE SUPPORT FOR CONDUIT FROM STRUCTURE AS NECESSARY. REFER TO DETAIL 4 /SHEET E5. ROUTE NEW 2" CONDUIT FROM 24" BELOW CEILING AT LOCATION SHOWN TO BUILDING SERVICE TELCO LOCATION. FIELD VERIFY LOCATION OF EXISTING CIRCUITRY. COORDINATE REQUIRED NUMBER OF PAIRS WITH VERIZON WIRELESS. DEDICATED RACK POWER. PROVIDE 125V NEMA LF -30R, 30A TWIST -LOCK RECEPTACLE PER EQUIPMENT MANUFACTURER'S REQUIREMENTS. L -116 -A +24' ±z4" 29 30 33 29 SEPARATE PERMIT I REQUIRED FOR: Mechanical K ilumbing ❑ Electrical Einas Piping City of Tukwila BUILDING DIVISION DEDICATED POWER FOR TELCO RACK. F2 DATA OUTLET FOR WALL - MOUNTED TELEPHONE. CORRECTION FILE Y Permit M DEDICATED POWER FOR SECURITY EQUIPMENT. COORDINATE EXACT REQUIREMENTS WITH EQUIPMENT SUPPLIER. POWER FOR IN -STORE MUSIC SYSTEM. COORDINATE WALL PENETRATION LOCATION WITH VERIZON WIRELESS PROJECT MANAGER, ARCHITECT, AND SIGN MANUFACTURER. MAKE ALL FINAL CONNECTIONS TO EXTERIOR SIGNAGE. J -BOX, ABOVE ACCESSIBLE CEILING, WITH LOCAL DISCONNECT SWITCH, FOR EXTERIOR SIGNAGE, SHALL CONTAIN (1) 120 -V, 20 -AMP CIRCUIT. ALL BRANCH CIRCUIT WIRING TO THE SIGN SHALL BE PER UL2161 FOR GFCI SIGN TRANSFORMERS. UL2161 REQUIRES THAT ALL CIRCUITS SHALL HAVE A DEDICATED HOT, NEUTRAL, AND GROUND TERMINATING AT THE ELECTRICAL PANELBOARD. COORDINATE WITH VERIZON WIRELESS PROJECT MANAGER. ROUTE CIRCUIT THROUGH CONTACTOR "C3" VIA TIMESWITCH 'l E ". REFER TO DETAIL 2 /SHEET E4 32 RE: DETAIL 1/ SHEET E2 FOR CONTINUATION TO RESTROOM LIGHT FIXTURE. CONNECT EXHAUST FAN EF -1 WITH RESTROOM LIGHT SWITCH SUCH THAT EXHAUST FAN RUNS WHEN EITHER RESTROOM LIGHT FIXTURE IS "ON ". PROVIDE RELAY, CIRCUITRY, ETC. AS NECESSARY. PROVIDE POWER AND DATA CONNECTION IN LOCATION SHOWN FOR QUE SCREEN. ELo1 585 FIDE COPY City of Tukwila BUILDING DIVISION fi • 51.,, Pian review approval Is 8 to en= am, ondselone. � �� does not authorize of approved Copy and ; BY We, / 2- / 7- 627 REVIEWED MPLIP►I�CE CODE C NFPA 70 - NEC NOV 2 6 2 1 City Of Tukwila gUliaDINC D� APPROVED PI " S C r fCAr ' OP 1L, y � ^ 1 1, ' ' "ANGED, MODIFIED OR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING OFrs , L, ALL WORK SHALL BE DUNE IN ACCORDANCE W!TH THE APPROVED PLANS AND Is IS,;ECT TO F!:' INSPECTIONS, Public Works, Bulling Division PERMIT NUMBER RECEIVED NOV 1 4 2007 PERMIT CENTEA-i i co °° W PROJ. 2007 -0174 DRWN. EC DATE 9 -25 -07 El 21.0F27 29 INVENT(; Loo WP /GFc 1 PA: L- 1-61-A TI C2 C1 r 10 116 ---A L -116 POWER FOR HVAC UNIT NZ UNIT ABOVE DOOR •Y 22 L -116 20 L -116 -A GFCI L -116 E3R1_,�K AHF A 32 I3ACK AkLA I ilf{ 1 POWER AND DATA FOR SECURITY SECURITY PANELS SECURITY EQUIPMENT, BOTTOM OF SHELF 0 - W US. TELCO ROOM PLAN NOT TO SCALE 1 1 32 1 1 '21 L -116 16 -A 1 107 12' LONG GROUNDING BAR 0 z 6' AFF 0 TELEPHONE COMM 4'-0' LONG, 4' 4 SLEEVE WIIH BUSHINGS QUAD OUTLET ® +18" AF.F. 30 AMP TWIST LOCI( OUTLET 0 +18' AFF. (NEM 15 -30R) CABLE TRAY ABOVE TacO RACK 28 L -116 POWER FOR TN STORE MUSIC +70' AFF. IN STORE MUSIC SiSTEII 0 +6O" AFF. 2" 4 TELEPHONE CONDUIT TO MAIN POINT OF ENTRY WITH PULL 5N(NG (-0' LONG 4 0 SLEEVE WITH BUSHINGS CABLE TRAY ABOVE TELEPHONE PAGING SYSTEM ON WALL BEYOND TELCO RACK If LONG GROUNDING FAR 0 +36' AFF TELCO ROOM ELEVATION NOT TO SCALE L-- 16 1 mAh1ACCE t 29 L -116 SECURITY LM BOTTOM 0 +86" AFF. SECURITY PANELS 4'-0" LONG 4' 0 SLEEVE BUSHINGS TELEPHONE PAC= CABLE TRAY ABOVE TELCO RACK 30 AMP TWIST LOCK +18" AFF. (NEMA 15 -30R) QUAD OUTLET 0 +18' AFF. UPS ON FLOOR r -I 1R' 27 L -116 L .. 1 1 �`? 74" SKEWED (TYP) L -116 17(PART) L -116 L -116 23 14 12 116=A t 30 /2 /NF L -116 3(PART) 4(PART) t L -116 C TELCO ROOM ELEVATION NOT TO SCALE f-11/2• CI,1ST@iV . R'lf n: - - 7 TELCO ROOM ELEVATION NOT TO SCALE TELCO ROOM ELEVATION NOT TO SCALE L -116 POWER FOR HVAC UNIT 0 99' A.F.F. HVAC UNIT ABOVE DOOR }VAC PUMP SECURITY MR BOTTOM 0 +86' POWER AFF. SECURITY PANELS l L -116 - 5 POWER PLAN SCALE: 1/4"- L-116 1 11 4 7 8 161 9 1(PART) L -116 2(PART) L -116 1, Mk MMEI 'r► Mrr 11+ . L -116 t I L-116 38 421 40 WP /GFC ELECTRICAL PLAN NOTES: POWER RECEPTACLE FOR VZTV. GENERAL ELECTRICAL NOTES: / • L -116 18 f~v COPY/FAX _' 1. PROVIDE A CODE SIZE GREEN EQUIPMENT GROUNDING CONDUCTOR FOR ALL LINE VOLTAGE CIRCUITS. 2. PROVIDE BACK BOXES WITH 1/2" CONDUIT STUBBED TO ABOVE CEILING WITH BUSHING FOR ALL WALL - MOUNTED HVAC CONTROLLERS. REFER TO MECHANICAL DRAWINGS FOR LOCATIONS. 3. ELECTRICAL CONTRACTOR SHALL COORDINATE PLACEMENT OF POWER AND DATA OUTLETS WITH CABINET CONTRACTOR IN ORDER THAT THEY ARE CENTERED INSIDE LOWER CABINETS. ROUTE CIRCUIT THROUGH CONTACTOR "Cl" AND CONTROL VIA TIMESWITCH "TI ". REFER TO DETAIL 3 AND CONTACTOR SCHEDULE ON SHEET E4. 20 -A RECEPTACLE, FLUSH IN CEILING, ABOVE STORE WINDOW, FOR HANGING FUTURE POWERED DISPLAY UNITS. COORDINATE EXACT LOCATION WITH ARCHITECT. L11 WALKER 880 OMNIBOX SERIES TWO -GANG CAST IRON FLOOR BOX FOR (1) FLUSH DUPLEX RECEPTACLE AND (4) FLUSH CATEGORY 5 COMMUNICATION JACKS FOR PHONE TABLE. REFER TO DETAILS 7 AND 13 /SHEET E5. FLOORBOX - #880CS2 COVER PLATE FLANGE = #827TCAL (BLACK) DUPLEX COVER PLATE _ #828R -TCAL (BLACK) COMMUNICATION COVER PLATE - #829PSTC -BLK (BLACK) COVER PLATES SHALL BE FLUSH WITH FLOORING. PROVIDE (1) 1" CONDUIT, WITH PULL STRINGS FOR POWER AND (1) 1-- 1/2" CONDUIT, WITH PULL STRING FOR DATA. ROUTE CONDUITS UNDER SLAB. STUB DATA UP IN WALL TO 6" ABOVE CEILING LINE. PROVIDE WITH END BUSHING. REFER TO DETAIL 5 /SHEET E5. WALKER 880 OMNIBOX SERIES THREE -GANG CAST IRON FLOOR BOX WITH (2) DUPLEX RECEPTACLES AND (1) OPEN BOX (NO COVER) FOR DATA PULL FOR DEMO BAR. REFER TO DETAILS 7 AND 15 /SHEET E5. FLOORBOX = #880053 COVER PLATE FLANGE - #837TCAL (BLACK) DUPLEX COVER PLATE = #828R -TCAL (BLACK), TYP. OF 2 COMMUNICATION COVER PLATE _ #829CKTCAL -1 (BLACK) COVER PLATES SHALL BE FLUSH WITH FLOORING. PROVIDE (1) 1" CONDUIT, WITH PULL STRINGS FOR POWER AND (1) 2" CONDUIT FOR DATA ROUTE CONDUITS UNDER SLAB. STUB DATA UP IN WALL TO 6" ABOVE CEILING UNE. PROVIDE WITH END BUSHING. ROUTE (1) 1" CONDUIT FOR SECURITY VENDOR FROM OUTLET BOX ON WALL, INSIDE CABINET TO ABOVE CEILING. REFER TO DETAIL 5 /SHEET E5. WALKER 880 OMNIBOX SERIES TWO -GANG CAST IRON FLOOR BOX FOR (1) AMP #557652-1 16" LINE ENTRY CABLE AND (1) OPEN BOX FOR DATA PULL FOR FREESTANDING POS. REFER TO DETAIL 7 /SHEET E5. FLOORBOX = #880CS2 COVER PLATE FLANGE = #827TCAL (BLACK) POWER COVER PLATE - 829CKTTCAL -1 (BLACK) COMMUNICATION COVER PLATE - #829CKTTCAL -1 (BLACK) COVER PLATES SHALL BE FLUSH WITH FLOORING. L-116 6(PART) d ' u L -116 1(PART) L -116 m 15 16 m 18 19 Eta 24 RI:.TAIE. '..3ALES q 9 , _`( - .. i1► 11► 2(PART) L -116 - -2 - - L -116 3(PART) L -116 4(PART) _ . _ 4- - -- REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division, N 1-7: Revisions will require a new plan submittal • r ly include additional plan review flees ` 7 ( ` 7 r L -116 5(PART) 10 L -116 L -116 6(PART) 10 WALKER 880 OMNIBOX SERIES THREE -GANG CAST IRON FLOOR BOX WITH (2) 25 DUPLEX RECEPTACLES AND (4) CATEGORY 5 COMMUNICATION JACKS FOR CUSTOMER CHECK -IN FIXTURE. REFER TO DETAIL 7 AND 14 /SHEET E5. 26 FLOORBOX = #880CS3 COVER PLATE FLANGE = #837TCAL (BLACK) DUPLEX COVER PLATE _ #828R —TCAL (BLACK), TYP. OF 2 COMMUNICATION COVER PLATE = #829PSTC —BLK (BLACK) COVER PLATES SHALL BE FLUSH WITH FLOORING. PROVIDE DUCT DETECTORS IN SUPPLY AND RETURN DUCTS FOR MECHANICAL EQUIPMENT UNLESS EXISTING. PROVIDE REMOTE TEST STATION AND AUDIO VISUAL DEVICE WITH KEYED RESET UNLESS EXISTING. COORDINATE EXACT LOCATION WITH OWNER'S REPRESENTATIVE. WP /GFCI RECEPTACLE AT RTU. PROVIDE IF NOT EXISTING. 13 REFER TO EQUIPMENT SCHEDULE ON SHEET M2 FOR DISCONNECT. R. POWER SUPPLY FOR CONTINUOUS PLUGMOLD STRIP. LOAD CALCULATED AS 180VA /5LF PER CODE. REFER TO DETAIL 3 /SHEET E5. AMP MODULAR POWER RECEPTACLES PROVIDED AND INSTALLED BY CASEWORK MANUFACTURER. DATA WIRING BY VERIZON WIRELESS. PROVIDE JUNCTION BOX AND AMP #557652 -1 16" LINE ENTRY CABLE FOR MANUFACTURED WIRING SYSTEM FEED. REFER TO DETAIL 1 /SHEET E5. PARTS TO BE ORDERED FROM WEIDENBACK -BROWN ALONG WITH LICHT FIXTURES. REFER TO GENERAL LIGHTING NOTES 5 AND 6 /SHEET E2. PROVIDE JUNCTION BOX AND AMP #557652 -3 96" LINE ENTRY CABLE FOR MANUFACTURED WIRING SYSTEM FEED. REFER TO DETAIL 2 /SHEET E5. PARTS TO BE ORDERED FROM WEIDENBACK -BROWN ALONG WITH LIGHT FIXTURES. REFER TO GENERAL LIGHTING NOTES 5 AND 6 /SHEET E2. PROVIDE (1) 2" CONDUIT FOR DATA. ROUTE CONDUIT AND POWER FEED THROUGH ADA UNDER COUNTER COMPARTMENT. STUB DATA UP IN WALL TO 6" ABOVE CEILING LINE. PROVIDE WITH END BUSHING. COORDINATE WITH CASEWORK PROVIDER. RE: DETAIL 2 /SHEET E5. 20 DUPLEX RECEPTACLE AND SINGLE GANG J -BOX WITH BLANK COVER, 3/4" CONDUIT TO 6" ABOVE CEILING, AND END BUSHING. INSTALL 8" BELOW CEILING FOR SECURITY MONITOR CONNECTIONS. 3/4" FIRE RATED, PAINTED CDX PLYWOOD TELEPHONE EQUIPMENT BOARD FLOOR TO CEILING ON ALL WALLS. COORDINATE EXACT LOCATION WITH VERIZON WIRELESS. 22 4' -0" LONG, 4" CONDUIT WITH BUSHINGS AT EACH END. CONDUIT SHALL EXTEND 2' -0" ABOVE AND BELOW CEILING. PROVIDE SUPPORT FOR CONDUIT FROM STRUCTURE AS NECESSARY. REFER TO DETAIL 4 /SHEET E5. ROUTE NEW 2" CONDUIT FROM 24" BELOW CEILING AT LOCATION SHOWN TO BUILDING SERVICE TELCO LOCATION. FIELD VERIFY LOCATION OF EXISTING CIRCUITRY. COORDINATE REQUIRED NUMBER OF PAIRS WITH VERIZON WIRELESS. DEDICATED RACK POWER. PROVIDE 125V NEMA LF -30R, 30A TWIST -LOCK RECEPTACLE PER EQUIPMENT MANUFACTURER'S REQUIREMENTS. L -116 -A +24' ±z4" 29 30 33 29 SEPARATE PERMIT I REQUIRED FOR: Mechanical K ilumbing ❑ Electrical Einas Piping City of Tukwila BUILDING DIVISION DEDICATED POWER FOR TELCO RACK. F2 DATA OUTLET FOR WALL - MOUNTED TELEPHONE. CORRECTION FILE Y Permit M DEDICATED POWER FOR SECURITY EQUIPMENT. COORDINATE EXACT REQUIREMENTS WITH EQUIPMENT SUPPLIER. POWER FOR IN -STORE MUSIC SYSTEM. COORDINATE WALL PENETRATION LOCATION WITH VERIZON WIRELESS PROJECT MANAGER, ARCHITECT, AND SIGN MANUFACTURER. MAKE ALL FINAL CONNECTIONS TO EXTERIOR SIGNAGE. J -BOX, ABOVE ACCESSIBLE CEILING, WITH LOCAL DISCONNECT SWITCH, FOR EXTERIOR SIGNAGE, SHALL CONTAIN (1) 120 -V, 20 -AMP CIRCUIT. ALL BRANCH CIRCUIT WIRING TO THE SIGN SHALL BE PER UL2161 FOR GFCI SIGN TRANSFORMERS. UL2161 REQUIRES THAT ALL CIRCUITS SHALL HAVE A DEDICATED HOT, NEUTRAL, AND GROUND TERMINATING AT THE ELECTRICAL PANELBOARD. COORDINATE WITH VERIZON WIRELESS PROJECT MANAGER. ROUTE CIRCUIT THROUGH CONTACTOR "C3" VIA TIMESWITCH 'l E ". REFER TO DETAIL 2 /SHEET E4 32 RE: DETAIL 1/ SHEET E2 FOR CONTINUATION TO RESTROOM LIGHT FIXTURE. CONNECT EXHAUST FAN EF -1 WITH RESTROOM LIGHT SWITCH SUCH THAT EXHAUST FAN RUNS WHEN EITHER RESTROOM LIGHT FIXTURE IS "ON ". PROVIDE RELAY, CIRCUITRY, ETC. AS NECESSARY. PROVIDE POWER AND DATA CONNECTION IN LOCATION SHOWN FOR QUE SCREEN. ELo1 585 FIDE COPY City of Tukwila BUILDING DIVISION fi • 51.,, Pian review approval Is 8 to en= am, ondselone. � �� does not authorize of approved Copy and ; BY We, / 2- / 7- 627 REVIEWED MPLIP►I�CE CODE C NFPA 70 - NEC NOV 2 6 2 1 City Of Tukwila gUliaDINC D� APPROVED PI " S C r fCAr ' OP 1L, y � ^ 1 1, ' ' "ANGED, MODIFIED OR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING OFrs , L, ALL WORK SHALL BE DUNE IN ACCORDANCE W!TH THE APPROVED PLANS AND Is IS,;ECT TO F!:' INSPECTIONS, Public Works, Bulling Division PERMIT NUMBER RECEIVED NOV 1 4 2007 PERMIT CENTEA-i r-0" 29 INVENT(; Loo WP /GFc 1 PA: L- 1-61-A TI C2 C1 r 10 116 ---A L -116 POWER FOR HVAC UNIT NZ UNIT ABOVE DOOR •Y 22 L -116 20 L -116 -A GFCI L -116 E3R1_,�K AHF A 32 I3ACK AkLA I ilf{ 1 POWER AND DATA FOR SECURITY SECURITY PANELS SECURITY EQUIPMENT, BOTTOM OF SHELF 0 - W US. TELCO ROOM PLAN NOT TO SCALE 1 1 32 1 1 '21 L -116 16 -A 1 107 12' LONG GROUNDING BAR 0 z 6' AFF 0 TELEPHONE COMM 4'-0' LONG, 4' 4 SLEEVE WIIH BUSHINGS QUAD OUTLET ® +18" AF.F. 30 AMP TWIST LOCI( OUTLET 0 +18' AFF. (NEM 15 -30R) CABLE TRAY ABOVE TacO RACK 28 L -116 POWER FOR TN STORE MUSIC +70' AFF. IN STORE MUSIC SiSTEII 0 +6O" AFF. 2" 4 TELEPHONE CONDUIT TO MAIN POINT OF ENTRY WITH PULL 5N(NG (-0' LONG 4 0 SLEEVE WITH BUSHINGS CABLE TRAY ABOVE TELEPHONE PAGING SYSTEM ON WALL BEYOND TELCO RACK If LONG GROUNDING FAR 0 +36' AFF TELCO ROOM ELEVATION NOT TO SCALE L-- 16 1 mAh1ACCE t 29 L -116 SECURITY LM BOTTOM 0 +86" AFF. SECURITY PANELS 4'-0" LONG 4' 0 SLEEVE BUSHINGS TELEPHONE PAC= CABLE TRAY ABOVE TELCO RACK 30 AMP TWIST LOCK +18" AFF. (NEMA 15 -30R) QUAD OUTLET 0 +18' AFF. UPS ON FLOOR r -I 1R' 27 L -116 L .. 1 1 �`? 74" SKEWED (TYP) L -116 17(PART) L -116 L -116 23 14 12 116=A t 30 /2 /NF L -116 3(PART) 4(PART) t L -116 C TELCO ROOM ELEVATION NOT TO SCALE f-11/2• CI,1ST@iV . R'lf n: - - 7 TELCO ROOM ELEVATION NOT TO SCALE TELCO ROOM ELEVATION NOT TO SCALE L -116 POWER FOR HVAC UNIT 0 99' A.F.F. HVAC UNIT ABOVE DOOR }VAC PUMP SECURITY MR BOTTOM 0 +86' POWER AFF. SECURITY PANELS l L -116 - 5 POWER PLAN SCALE: 1/4"- L-116 1 11 4 7 8 161 9 1(PART) L -116 2(PART) L -116 1, Mk MMEI 'r► Mrr 11+ . L -116 t I L-116 38 421 40 WP /GFC ELECTRICAL PLAN NOTES: POWER RECEPTACLE FOR VZTV. GENERAL ELECTRICAL NOTES: / • L -116 18 f~v COPY/FAX _' 1. PROVIDE A CODE SIZE GREEN EQUIPMENT GROUNDING CONDUCTOR FOR ALL LINE VOLTAGE CIRCUITS. 2. PROVIDE BACK BOXES WITH 1/2" CONDUIT STUBBED TO ABOVE CEILING WITH BUSHING FOR ALL WALL - MOUNTED HVAC CONTROLLERS. REFER TO MECHANICAL DRAWINGS FOR LOCATIONS. 3. ELECTRICAL CONTRACTOR SHALL COORDINATE PLACEMENT OF POWER AND DATA OUTLETS WITH CABINET CONTRACTOR IN ORDER THAT THEY ARE CENTERED INSIDE LOWER CABINETS. ROUTE CIRCUIT THROUGH CONTACTOR "Cl" AND CONTROL VIA TIMESWITCH "TI ". REFER TO DETAIL 3 AND CONTACTOR SCHEDULE ON SHEET E4. 20 -A RECEPTACLE, FLUSH IN CEILING, ABOVE STORE WINDOW, FOR HANGING FUTURE POWERED DISPLAY UNITS. COORDINATE EXACT LOCATION WITH ARCHITECT. L11 WALKER 880 OMNIBOX SERIES TWO -GANG CAST IRON FLOOR BOX FOR (1) FLUSH DUPLEX RECEPTACLE AND (4) FLUSH CATEGORY 5 COMMUNICATION JACKS FOR PHONE TABLE. REFER TO DETAILS 7 AND 13 /SHEET E5. FLOORBOX - #880CS2 COVER PLATE FLANGE = #827TCAL (BLACK) DUPLEX COVER PLATE _ #828R -TCAL (BLACK) COMMUNICATION COVER PLATE - #829PSTC -BLK (BLACK) COVER PLATES SHALL BE FLUSH WITH FLOORING. PROVIDE (1) 1" CONDUIT, WITH PULL STRINGS FOR POWER AND (1) 1-- 1/2" CONDUIT, WITH PULL STRING FOR DATA. ROUTE CONDUITS UNDER SLAB. STUB DATA UP IN WALL TO 6" ABOVE CEILING LINE. PROVIDE WITH END BUSHING. REFER TO DETAIL 5 /SHEET E5. WALKER 880 OMNIBOX SERIES THREE -GANG CAST IRON FLOOR BOX WITH (2) DUPLEX RECEPTACLES AND (1) OPEN BOX (NO COVER) FOR DATA PULL FOR DEMO BAR. REFER TO DETAILS 7 AND 15 /SHEET E5. FLOORBOX = #880053 COVER PLATE FLANGE - #837TCAL (BLACK) DUPLEX COVER PLATE = #828R -TCAL (BLACK), TYP. OF 2 COMMUNICATION COVER PLATE _ #829CKTCAL -1 (BLACK) COVER PLATES SHALL BE FLUSH WITH FLOORING. PROVIDE (1) 1" CONDUIT, WITH PULL STRINGS FOR POWER AND (1) 2" CONDUIT FOR DATA ROUTE CONDUITS UNDER SLAB. STUB DATA UP IN WALL TO 6" ABOVE CEILING UNE. PROVIDE WITH END BUSHING. ROUTE (1) 1" CONDUIT FOR SECURITY VENDOR FROM OUTLET BOX ON WALL, INSIDE CABINET TO ABOVE CEILING. REFER TO DETAIL 5 /SHEET E5. WALKER 880 OMNIBOX SERIES TWO -GANG CAST IRON FLOOR BOX FOR (1) AMP #557652-1 16" LINE ENTRY CABLE AND (1) OPEN BOX FOR DATA PULL FOR FREESTANDING POS. REFER TO DETAIL 7 /SHEET E5. FLOORBOX = #880CS2 COVER PLATE FLANGE = #827TCAL (BLACK) POWER COVER PLATE - 829CKTTCAL -1 (BLACK) COMMUNICATION COVER PLATE - #829CKTTCAL -1 (BLACK) COVER PLATES SHALL BE FLUSH WITH FLOORING. L-116 6(PART) d ' u L -116 1(PART) L -116 m 15 16 m 18 19 Eta 24 RI:.TAIE. '..3ALES q 9 , _`( - .. i1► 11► 2(PART) L -116 - -2 - - L -116 3(PART) L -116 4(PART) _ . _ 4- - -- REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division, N 1-7: Revisions will require a new plan submittal • r ly include additional plan review flees ` 7 ( ` 7 r L -116 5(PART) 10 L -116 L -116 6(PART) 10 WALKER 880 OMNIBOX SERIES THREE -GANG CAST IRON FLOOR BOX WITH (2) 25 DUPLEX RECEPTACLES AND (4) CATEGORY 5 COMMUNICATION JACKS FOR CUSTOMER CHECK -IN FIXTURE. REFER TO DETAIL 7 AND 14 /SHEET E5. 26 FLOORBOX = #880CS3 COVER PLATE FLANGE = #837TCAL (BLACK) DUPLEX COVER PLATE _ #828R —TCAL (BLACK), TYP. OF 2 COMMUNICATION COVER PLATE = #829PSTC —BLK (BLACK) COVER PLATES SHALL BE FLUSH WITH FLOORING. PROVIDE DUCT DETECTORS IN SUPPLY AND RETURN DUCTS FOR MECHANICAL EQUIPMENT UNLESS EXISTING. PROVIDE REMOTE TEST STATION AND AUDIO VISUAL DEVICE WITH KEYED RESET UNLESS EXISTING. COORDINATE EXACT LOCATION WITH OWNER'S REPRESENTATIVE. WP /GFCI RECEPTACLE AT RTU. PROVIDE IF NOT EXISTING. 13 REFER TO EQUIPMENT SCHEDULE ON SHEET M2 FOR DISCONNECT. R. POWER SUPPLY FOR CONTINUOUS PLUGMOLD STRIP. LOAD CALCULATED AS 180VA /5LF PER CODE. REFER TO DETAIL 3 /SHEET E5. AMP MODULAR POWER RECEPTACLES PROVIDED AND INSTALLED BY CASEWORK MANUFACTURER. DATA WIRING BY VERIZON WIRELESS. PROVIDE JUNCTION BOX AND AMP #557652 -1 16" LINE ENTRY CABLE FOR MANUFACTURED WIRING SYSTEM FEED. REFER TO DETAIL 1 /SHEET E5. PARTS TO BE ORDERED FROM WEIDENBACK -BROWN ALONG WITH LICHT FIXTURES. REFER TO GENERAL LIGHTING NOTES 5 AND 6 /SHEET E2. PROVIDE JUNCTION BOX AND AMP #557652 -3 96" LINE ENTRY CABLE FOR MANUFACTURED WIRING SYSTEM FEED. REFER TO DETAIL 2 /SHEET E5. PARTS TO BE ORDERED FROM WEIDENBACK -BROWN ALONG WITH LIGHT FIXTURES. REFER TO GENERAL LIGHTING NOTES 5 AND 6 /SHEET E2. PROVIDE (1) 2" CONDUIT FOR DATA. ROUTE CONDUIT AND POWER FEED THROUGH ADA UNDER COUNTER COMPARTMENT. STUB DATA UP IN WALL TO 6" ABOVE CEILING LINE. PROVIDE WITH END BUSHING. COORDINATE WITH CASEWORK PROVIDER. RE: DETAIL 2 /SHEET E5. 20 DUPLEX RECEPTACLE AND SINGLE GANG J -BOX WITH BLANK COVER, 3/4" CONDUIT TO 6" ABOVE CEILING, AND END BUSHING. INSTALL 8" BELOW CEILING FOR SECURITY MONITOR CONNECTIONS. 3/4" FIRE RATED, PAINTED CDX PLYWOOD TELEPHONE EQUIPMENT BOARD FLOOR TO CEILING ON ALL WALLS. COORDINATE EXACT LOCATION WITH VERIZON WIRELESS. 22 4' -0" LONG, 4" CONDUIT WITH BUSHINGS AT EACH END. CONDUIT SHALL EXTEND 2' -0" ABOVE AND BELOW CEILING. PROVIDE SUPPORT FOR CONDUIT FROM STRUCTURE AS NECESSARY. REFER TO DETAIL 4 /SHEET E5. ROUTE NEW 2" CONDUIT FROM 24" BELOW CEILING AT LOCATION SHOWN TO BUILDING SERVICE TELCO LOCATION. FIELD VERIFY LOCATION OF EXISTING CIRCUITRY. COORDINATE REQUIRED NUMBER OF PAIRS WITH VERIZON WIRELESS. DEDICATED RACK POWER. PROVIDE 125V NEMA LF -30R, 30A TWIST -LOCK RECEPTACLE PER EQUIPMENT MANUFACTURER'S REQUIREMENTS. L -116 -A +24' ±z4" 29 30 33 29 SEPARATE PERMIT I REQUIRED FOR: Mechanical K ilumbing ❑ Electrical Einas Piping City of Tukwila BUILDING DIVISION DEDICATED POWER FOR TELCO RACK. F2 DATA OUTLET FOR WALL - MOUNTED TELEPHONE. CORRECTION FILE Y Permit M DEDICATED POWER FOR SECURITY EQUIPMENT. COORDINATE EXACT REQUIREMENTS WITH EQUIPMENT SUPPLIER. POWER FOR IN -STORE MUSIC SYSTEM. COORDINATE WALL PENETRATION LOCATION WITH VERIZON WIRELESS PROJECT MANAGER, ARCHITECT, AND SIGN MANUFACTURER. MAKE ALL FINAL CONNECTIONS TO EXTERIOR SIGNAGE. J -BOX, ABOVE ACCESSIBLE CEILING, WITH LOCAL DISCONNECT SWITCH, FOR EXTERIOR SIGNAGE, SHALL CONTAIN (1) 120 -V, 20 -AMP CIRCUIT. ALL BRANCH CIRCUIT WIRING TO THE SIGN SHALL BE PER UL2161 FOR GFCI SIGN TRANSFORMERS. UL2161 REQUIRES THAT ALL CIRCUITS SHALL HAVE A DEDICATED HOT, NEUTRAL, AND GROUND TERMINATING AT THE ELECTRICAL PANELBOARD. COORDINATE WITH VERIZON WIRELESS PROJECT MANAGER. ROUTE CIRCUIT THROUGH CONTACTOR "C3" VIA TIMESWITCH 'l E ". REFER TO DETAIL 2 /SHEET E4 32 RE: DETAIL 1/ SHEET E2 FOR CONTINUATION TO RESTROOM LIGHT FIXTURE. CONNECT EXHAUST FAN EF -1 WITH RESTROOM LIGHT SWITCH SUCH THAT EXHAUST FAN RUNS WHEN EITHER RESTROOM LIGHT FIXTURE IS "ON ". PROVIDE RELAY, CIRCUITRY, ETC. AS NECESSARY. PROVIDE POWER AND DATA CONNECTION IN LOCATION SHOWN FOR QUE SCREEN. ELo1 585 FIDE COPY City of Tukwila BUILDING DIVISION fi • 51.,, Pian review approval Is 8 to en= am, ondselone. � �� does not authorize of approved Copy and ; BY We, / 2- / 7- 627 REVIEWED MPLIP►I�CE CODE C NFPA 70 - NEC NOV 2 6 2 1 City Of Tukwila gUliaDINC D� APPROVED PI " S C r fCAr ' OP 1L, y � ^ 1 1, ' ' "ANGED, MODIFIED OR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING OFrs , L, ALL WORK SHALL BE DUNE IN ACCORDANCE W!TH THE APPROVED PLANS AND Is IS,;ECT TO F!:' INSPECTIONS, Public Works, Bulling Division PERMIT NUMBER RECEIVED NOV 1 4 2007 PERMIT CENTEA-i I ELECTRICAL FIXTURE SCHEDULE I TAG MANUFACTURER SYMBOLS CATALOG NO. LAMPS INPUT VA DESCRIPTION NO. TYPE VOLT C METALUX 2GR8 -332A- 120 -E881 3 32WT8 /SP30 /ECO 3000K, CRI 78 120 96 2'X4' ACRYLIC LENS TROFFER 1 0 CS METALUX 2M- 332A - 120V ---• EB81 3 32WT8 (48 ") 3000K, CRI 78 120 96 2'X4', SURFACE MOUNT FLUORESCENT WITH ACRYLIC LENS. I 0 D METALUX 2GR8 -332A- 120- EM -EB81 BALLAST: IOTA 1232 3 32WT8 /SP30 /ECO 3000K, CRI 78 120 96 2'X4' ACRYLIC LENS TROFFER WITH EM BATTERY PACK EM BALLAST TO ILLUMINATE 2 LAMPS IN PARALLEL 4140A1 E DELRAY LIGHTING Q 6402.18 -5 X 18W CFL 5 18W CFL 3000K, CRI 82 120 90 CYUNDRO WITH SEPARATE MOUNTING POINTS F JUNO 0 CV6- 1/32T -600C 1 32WTBX /830 /A /ECO 3000K, CRI 82 120 36 6" RECESSED DOWNLIGHT WITH LOW IRRIDESCENT FINISH. G JUNO 0 CV6- 132T- 600C -PLK -E 1 32WTBX /830 /A /ECO 3000K, CRI 82 120 36 6" RECESSED DOWNLIGHT WITH LOW IRRIDESCENT FINISH WITH EM BALLAST. H ARCHITECTURAL LIGHTING WORKS L4- S082- S- S -S--S 1 CNH2OT /U830GU6.5 120 80 4 -HEAD SUSPENDED LUMINAIRE ARRANGEMENT PER PLANS ID O O ol K BEST LIGHTING PRODUCTS 0 EZXTEU *RW -EM - - 120 5 EMERGENCY EXIT SIGN (RE: PLANS FOR QTY. OF SIDES AND CHEVRONS) L LITHONIA 0 LRP- 1 -RC -1 20/277 -EL N - 120 5 EDGE LIT EMERGENCY EXIT SIGN N LIGHTOLIER IFI"Y" HEADS: MR16 GLASS RING WH ** TRACK: 650 SERIES WH 1 12V 50W MR16 120 50 TRACK FIXTURE. LENGTH AND NUMBER OF HEADS PER PLAN NN LIGHTOLIER 1^ HEADS: 22M4 WH ** TRACK: 650 SERIES WH 2 50W T4 2 -PIN GY6.35 120 80 TRACK FIXTURE. LENGTH AND NUMBER OF HEADS PER PLAN NC LIGHTOLIER MJ HEADS: 22MW62H 120V ** CANOPY ADAPTER: L973 MB 1 12V 50W MR16 120 50 MONOPOINT TRACK FIXTURE Q LIGHTOLIER 0 8067 CLW 2 7213LPM120 120 26 CALCULITE COMPACT FLOURESCENT DOWNLIGHT U H.E. WILLIAMS, INC 2SF -24 *-- 125- WRS -EB1 -120 *LENGTH PER PLANS (24 ", 36" & 48" AVAILABLE) 1 F25T8 /SPX30 (ALTER PER LENGTH) 120 18 UNDERCABINET LIGHT. LENGTH PER PLANS L -116 L -116 -A cUSTc 1a S RVICE 4 >1 C 1 i� C . TITILA CS `- JANITOR CI. LIGHTING PLAN SCALE: 1 /4" =1' -0" •• ••• H IV ' •••• . NOTE: ALL LIGHT FIXTURES AND LAMPS ARE TO BE PROVIDED BY ELECTRICAL CONTRACTOR PURCHASED FROM VERIZON'S VENDOR. COORDINATE WITH VERIZON WIRELESS PROJECT MANAGER. T' GENERAL LIGHTING NOTES: 1. ALL "N ", "NC" AND "NN" TRACK SYSTEMS AND TRACK LIGHT FIXTURES SHALL BE BY IGHTOLIER. QUANTITY OF HEADS SHALL BE AS SHOWN ON DRAWINGS, UNLESS OTHERWISE DETERMINED BY DESIGN PROFESSIONAL AND VERIZON WIRELESS PROJECT MANAGER. 2. EMERGENCY LIGHT FIXTURES SHALL BE WIRED IN A NORMALLY "ON" NIGHT LIGHT CONFIGURATION UNLESS NOTED OTHERWISE. 3. PROVIDE A CODE SIZE GREEN EQUIPMENT GROUNDING CONDUCTOR FOR ALL LINE VOLTAGE CIRCUITS. 4. ALL EXTERIOR EGRESS LIGHTING AND EXTERIOR EMERGENCY EGRESS LIGHTING PROVIDED BY LANDLORD. 5. ON THE WEST COAST, ELECTRICAL CONTRACTOR SHALL CONTACT SCOTT BRANDINO OF WEIDENBACH -BROWN (714- 692 -2200, EXT. 323) TO ORDER ALL LIGHTING FIXTURES. COORDINATE WITH VERIZON WIRELESS PROJECT MANAGER. 6. ON THE EAST COAST, ELECTRICAL CONTRACTOR SHALL CONTACT MIKE MCLAREN OF WEIDENBACH -BROWN (914- 846 -1423) TO ORDER ALL LIGHTING FIXTURES. COORDINATE WITH VERIZON WIRELESS PROJECT MANAGER. LIGHTING PLAN NOTES: 11 4 6 L -116 -A 15(PART) ■ SWITCH BANK LOCATION FOR RETAIL SALES, CUSTOMER SERVICE AND BACK AREA LIGHTING. REFER TO DETAIL 3 /SHEET E4. ROUTE CIRCUIT THROUGH CONTACTOR "C2" AND CONTROL VIA WALL SWITCH. RE: DETAIL 3 /SHEET E4. PROVIDE WALL MOUNTED INFRARED OCCUPANCY SENSOR FOR AUTOMATIC SHUTOFF CONTROL OF ROOM LIGHTING. OCCUPANCY SENSOR SHALL BE WATTSTOPPER MODEL #WS -200 OR APPROVED EQUAL. ADJUST OCCUPANCY SENSOR TO 30- MINUTE MAXIMUM DELAY. ALL FIXTURES OUTSIDE VERIZON WIRELESS' LEASE SPACE WILL BE BY LANDLORD UNLESS NOTED OTHERWISE, INCLUDING ALL NORMAL AND EMERGENCY EGRESS AND EXIT LIGHTING REQUIRED PER APPLICABLE BUILDING CODE. ROUTE CIRCUIT THROUGH CONTACTOR "C1" AND CONTROL VIA TIMESWITCH "T ". RE: DETAIL 3 /SHEET E4. RE:1 /E1 FOR CONTINUATION TO EF -1. 4 4 L -116 -A p�pNCE COO PA �0 - NEC N� WN 2.6 201 C pf Tukwila RECEWWEr1 NOV 14 2007 PERMIT CEIN I Eh <1... ti r§: Cd8 P ROJ. 2007-0/74 DRWN. EC DATE 9 -25 -07 2 22 OF 27 L -116 L -116 -A cUSTc 1a S RVICE 4 >1 C 1 i� C . TITILA CS `- JANITOR CI. LIGHTING PLAN SCALE: 1 /4" =1' -0" •• ••• H IV ' •••• . NOTE: ALL LIGHT FIXTURES AND LAMPS ARE TO BE PROVIDED BY ELECTRICAL CONTRACTOR PURCHASED FROM VERIZON'S VENDOR. COORDINATE WITH VERIZON WIRELESS PROJECT MANAGER. T' GENERAL LIGHTING NOTES: 1. ALL "N ", "NC" AND "NN" TRACK SYSTEMS AND TRACK LIGHT FIXTURES SHALL BE BY IGHTOLIER. QUANTITY OF HEADS SHALL BE AS SHOWN ON DRAWINGS, UNLESS OTHERWISE DETERMINED BY DESIGN PROFESSIONAL AND VERIZON WIRELESS PROJECT MANAGER. 2. EMERGENCY LIGHT FIXTURES SHALL BE WIRED IN A NORMALLY "ON" NIGHT LIGHT CONFIGURATION UNLESS NOTED OTHERWISE. 3. PROVIDE A CODE SIZE GREEN EQUIPMENT GROUNDING CONDUCTOR FOR ALL LINE VOLTAGE CIRCUITS. 4. ALL EXTERIOR EGRESS LIGHTING AND EXTERIOR EMERGENCY EGRESS LIGHTING PROVIDED BY LANDLORD. 5. ON THE WEST COAST, ELECTRICAL CONTRACTOR SHALL CONTACT SCOTT BRANDINO OF WEIDENBACH -BROWN (714- 692 -2200, EXT. 323) TO ORDER ALL LIGHTING FIXTURES. COORDINATE WITH VERIZON WIRELESS PROJECT MANAGER. 6. ON THE EAST COAST, ELECTRICAL CONTRACTOR SHALL CONTACT MIKE MCLAREN OF WEIDENBACH -BROWN (914- 846 -1423) TO ORDER ALL LIGHTING FIXTURES. COORDINATE WITH VERIZON WIRELESS PROJECT MANAGER. LIGHTING PLAN NOTES: 11 4 6 L -116 -A 15(PART) ■ SWITCH BANK LOCATION FOR RETAIL SALES, CUSTOMER SERVICE AND BACK AREA LIGHTING. REFER TO DETAIL 3 /SHEET E4. ROUTE CIRCUIT THROUGH CONTACTOR "C2" AND CONTROL VIA WALL SWITCH. RE: DETAIL 3 /SHEET E4. PROVIDE WALL MOUNTED INFRARED OCCUPANCY SENSOR FOR AUTOMATIC SHUTOFF CONTROL OF ROOM LIGHTING. OCCUPANCY SENSOR SHALL BE WATTSTOPPER MODEL #WS -200 OR APPROVED EQUAL. ADJUST OCCUPANCY SENSOR TO 30- MINUTE MAXIMUM DELAY. ALL FIXTURES OUTSIDE VERIZON WIRELESS' LEASE SPACE WILL BE BY LANDLORD UNLESS NOTED OTHERWISE, INCLUDING ALL NORMAL AND EMERGENCY EGRESS AND EXIT LIGHTING REQUIRED PER APPLICABLE BUILDING CODE. ROUTE CIRCUIT THROUGH CONTACTOR "C1" AND CONTROL VIA TIMESWITCH "T ". RE: DETAIL 3 /SHEET E4. RE:1 /E1 FOR CONTINUATION TO EF -1. 4 4 L -116 -A p�pNCE COO PA �0 - NEC N� WN 2.6 201 C pf Tukwila RECEWWEr1 NOV 14 2007 PERMIT CEIN I Eh 'PANELBOARD: L -1 16 (NEW) Q FAULT CURRENT: REFER TO ONE -LINE DIAGRAM EQUIPMENT GROUND BUS Bir • • - . AIC RATING: FCA +10% MINIMUM, FULLY RATED MAIN SIZE/TYPE: MLO SERVES: FIRST FLOOR VOLTS /PHASE: 208Y/120V, 3PH, 4W MOUNTING: SURFACE SECTION: 1 LOCATION: BACK AREA, ROOM #:103 CKT NO. DESCRIPTION VOLTAMPS PHASE WIRE NO. BKR AMP P P BKR AMP WIRE NO. VOLTAMPS PHASE DESCRIPTION CKT NO. A B C A B C 1 RCPT -DEMO /CHECK -IN- SWITCHED 600 / / / / /', ' %/i //, 12 20 1 1 20 12 600 /i / //;/ ///////,/ / //: i 600 "2 //////// 400 RCPT -DEMO /CHECK -IN- UNSWITCHEI r RCPT - WHAT'S NEW- UNSWITCHED 0.25 100% 3 RCPT - WHAT'S NEW-SWITCHED ' //; // ; 600 gram 12 20 20 r r I r 20 20 12 12 MOM pr AA 800 ' /7// % /// / 600 % /T; ;///11 600 / / / /// 5 RCPT -SLTN WALL - SWITCHED i/, „/' Ippr MM 600 12 RCPT -SLTN WALL - UNSWITCHED RCPT - SALES DESK P05 #1 6 8 7 RCPT -PHONE TABLES 1,2 500 INZIME / // j/, 12 20 20 EXISTING LOAD TO BE DELETED 20 12 9 RCPT -PHONE TABLES 3,4 //////,,/ 500 ////",/ 12 20 20 12 12 RCPT -SALES DESK P05 #2 10 11 RCPT - SERVICE DESK P05 #1 /////// 400 12 20 FREE STANDING P03 #1 12 13 RCPT - SERVICE DESK P05 #2 400 % /. /', /K // i , _> 500 pf'r // ' ' A 900 12 12 12 12 20 20 20 20 Iv- I 3 20 20 12 12 400 ' FREE STANDING POS #2 14 15 RCPT -VZTV . J//I 600 RCPT -BILL PAY /MY ACCOUNT 16 17 RCPT -QUE SCREENS 20 12 / 1/M / 1,380 2 / / /,' // 3\ RCPT -SALES DESK COPIER 18 19 RCPT-TECH/OPS 720 1 / /// ./ ////// 20 12 RCPT -BREAK AREA 20 21 RCPT -TECH PLUGMOLD /''•y>, 360 / / 12 12 20 20 fi 20 12 /' �' 540 500 7 ' ' %z // 360 ' 1/////1 540 7/7/ ji i// // RCPT - REFRIGERATOR 22 20 12 23 RCPT -TELCO RACK /MUSIC % ;" ,/ 800 RCPT - MANAGER 24 26] 28 25 RCPT -IT EQUIPMENT 2,000 10 30 L -! 20 12 RCPT - INVENTORY 27 RCPT-SECURITY EQUIPMENT REIM 500 WAWA 12 20 20 12 • ' . RCPT-RESTROOMS %` /' i / // /„ 360 7 /' %i ; /� RCPT SERVICE/TECH 30 29 RCPT - SECURITY MONITOR 300 12 20 1 20 12 SPARE 32 31 SPARE /i /i // i �, /, 20 1 1 20 33 SPARE ///,.// 20 1 1 20 /// /� X21 ii SPARE 34 35 SPARE ',/ ;' // W.MA 20 3 0 60 6 260 _ / //, %/ , ' /,/i.L % /,' P R RTU -1 • 4; 40 37 SPACE 39 SPACE % , ; %! - „/®," `�, 5,260 41 SPACE / /�W V/ ; : 5,260 42 ( SUBTOTAL 4.220 2.460 3.000 • 8.980 7.920 _ 7.660 _ _ _ _ _ _ _ _ _ SUBTOTAL TOTAL PHASE A - VA 13,200 LOAD CONN. VA DF LOAD J CONN. VA DF COOLING 9,330 1.00 REFRIGERATION 1.00 AMPS 110 SIGN /DISPLAY 1.25 TOTAL PHASE B - VA 10,380 HEATING 0 AMPS 87 LIGHTING RECEPTACLES 3,060 KITCHEN 1.00 1.25 1.0/.5 1.00 1.00 1.00 TOTAL PHASE C - VA 10,660 EXISTING 1.00 AMPS 89 MOTORS SUPP HEAT 6,450 LARGE MOTOR 1.25 TOTAL DEMAND SHOW WINDOW 2,800 1.25 TOTAL PNLBD - VA 34,240 40,215 VA AMPS 95 MISC EQUIP 15,400 LTG TRACK 2,475 1.00 112 A PANELBOARD NOTES C# - VIA LTG CONTACTOR # LTG TRACK -- TRACK LENGTH SIGN /DISPLAY - SIGNAGE & DISPLAY CASE I PANELBOARD L -116 -A LOAD SUMMARY 1 208Y/120V, 3PH, 4W LOAD DESCRIPTION Connected KVA Demand FACTOR I Demand I KVA EXISTING LOAD 0.00 100% 0.00 HVAC - SUMMER 10.55 100% 10.55 HVAC - WINTER 0.00 100% 5.96 125% 0.00 7.45 LIGHTING RECEPTACLES 0.54 100 %;50% 0.54 KITCHEN EQUIPMENT 0.00 65% 0.00 MOTOR LOADS 5.48 100% 5.48 LARGEST MOTOR LOAD 0.00 125% 0.00 SUPPLEMENTAL ELECTRIC HEAT .3.00 100% 3.00 MISCELLANEOUS EQUIPMENT 0.25 100% 0.25 REFRIGERATION EQUIPMENT 0.00 100% 0.00 DISPLAY CASE 2.40 125% 3.00 SHOW WINDOW 5.28 PER NEC 5.98 EXTERIOR LIGHTING 0.00 125% 0.00 EXISTING LOAD TO BE DELETED 0.00 100% 0.00 0.00 SHOW WINDOW 5.28 PER NEC PROJ. DRWN. DATE 2007 -0174 EC 9 -25 -07 0.00 EXISTING LOAD TO BE DELETED 0.00 100% E3 23 OF 27 I PANELBOARD L -116 -A LOAD SUMMARY 1 208Y/120V, 3PH, 4W LOAD DESCRIPTION Connected KVA Demand FACTOR I Demand I KVA EXISTING LOAD 0.00 100% 0.00 HVAC - SUMMER 10.55 100% 10.55 HVAC - WINTER 0.00 100% 5.96 125% 0.00 7.45 LIGHTING RECEPTACLES 0.54 100 %;50% 0.54 KITCHEN EQUIPMENT 0.00 65% 0.00 MOTOR LOADS 5.48 100% 5.48 LARGEST MOTOR LOAD 0.00 125% 0.00 SUPPLEMENTAL ELECTRIC HEAT .3.00 100% 3.00 MISCELLANEOUS EQUIPMENT 0.25 100% 0.25 REFRIGERATION EQUIPMENT 0.00 100% 0.00 DISPLAY CASE 2.40 125% 3.00 SHOW WINDOW 5.28 PER NEC 5.98 EXTERIOR LIGHTING 0.00 125% 0.00 EXISTING LOAD TO BE DELETED 0.00 100% 0.00 PANELBOARD L - 116 LOAD SUMMARY 208Y/120V, 3PH, 4W LOAD DESCRIPTION Connected KVA Demand FACTOR I Demand I KVA EXISTING LOAD 0.00 100% 0.00 HVAC - SUMMER 9.33 100% 9.33 HVAC - WINTER 0.00 100% 125% 0.00 0.00 L IRTING 0.00 RECEPTACLES 3.06 100 %;50% 3.06 KITCHEN EQUIPMENT 0.00 65% 0.00 MOTOR LOADS 6.45 100% 6.45 LARGEST MOTOR LOAD 0.00 125% 0.00 SUPPLEMENTAL ELECTRIC HEAT 0.00 100% 0.00 - MISCELLANEOUS EQUIPMENT 15.40 100% 15.40 REFRIGERATION EQUIPMENT 0.00 100% 0.00 DISPLAY CASE 0.00 125% 0.00 SHOW WINDOW 5.28 PER NEC 5.9 EXTERIOR LIGHTING 0.00 125% 0.00 EXISTING LOAD TO BE DELETED 0.00 100% 0.00 TOTAL LOAD 33.44 KVA 36.23 TOTAL AMPACITY 92.82 AMPS 100.57 PANEL AMPACITY 200 AMPS 200.00 SPARE CAPACITY AMPS 99 TOTAL LOAD 39.52 KVA 40.22 TOTAL AMPACITY 109.68 AMPS 111.63 PANEL AMPACITY 200 AMPS 200.00 SPARE CAPACITY AMPS 88 0 EXIST EXIST 1 TO GROUND BAR AT MAIN TELEPHONE BOARD (TTB) TO STRUCTURAL STEEL TO ABOVE GROUND METAL PIPING TO WATER SERVICE TO BUILDING FOOTING (UFER) GENERAL ONE LINE NOTES: ELECTRICAL RISER NOTES: MDP (EXISTING) NEUTRAL BUST ' GROUND BUS x w n x w TO GROUND ROD(S) I 1 UTILITY COMPANY: PUGET SOUND ENERGY PHONE: (425) 452 -1234 DATE: 9/17/2007 AVAILABLE FAULT CURRENT: 65,000 AMPS x w x w EXISTING UTILITY TRANSFORMER 208Y/120V, 30, 4W SEC n x w 23,529 FCA 0.9 %CVD 40_ _ __ ( 2000A 3P ).< w 1. INFORMATION SHOWN ON TENANT DRAWINGS 15 INTENDED TO INDICATE MINIMUM REQUIREMENTS TO MEET NEED OF TENANT. VERIFY EXISTING CONDITIONS, CAPACITIES, AND OTHER PROVISIONS BY OTHERS PER TENANT LEASE AGREEMENT PRIOR TO BEGINING CONSTRUCTION. 2. THE LANDLORD IS CONTRACTUALLY OBLIGATED BY THE TENANT LEASE AGREEMENT TO PROVIDE AT LEAST 400A, 208Y/120V CAPACITY. ANY MODIFICATIONS REQUIRED TO PROVIDE SUCH CAPACITY IS THE RESPONSIBIUTY OF THE LANDLORD AND WILL BE PERFORMED UNDER SEPARATE CONTRACT /PERMIT. CONFIRM THIS IS POINT OF SERVICE ENTRANCE AND THAT NEUTRAL AND GROUND ARE BONDED TOGETHER AND TO THE GROUNDING ELECTRODE SYSTEM. MINIMUM SIZE REQUIRED PROVIDED THAT VOLTAGE DROP 15 LESS THAN 3% ALONG FEEDER LENGTH PER NEC REQUIREMENTS. 2000 AMPS 208Y/120V 30 4W ( 200A ( 200A 3P \ 3P UTILITY METER M/E ROOM N 9,114 FCA : 8,888 FCA 1.87 %CVD 1.92 %CVD 190 FEET 195 FEET UTILITY METER ELECTRICAL ONE -LINE DIAGRAM NO SCALE CIRCUIT SCHEDULE: ALL CONDUCTOR SIZES ARE BASED ON 75 DEG C RATED TERMINATION AND COPPER CONDUCTORS WITH TYPE THHN /THWN -2 INSULATION. WHERE ALUMINUM CONDUCTORS ARE ALLOWED PER SPECIFICATIONS AND FOR TERMINATION OR INSULATION TYPES RATED LESS THAN 75 DEG C, MODIFY SIZES ACCORDING TO NFPA 70. 1 204 1 1 DUST 1 200A, (4)- 250kcmil, (1) #6G, 2" C EXISTING TO REMAIN C1 C1 C1 C3 C3 3 C2,EM 5 C2,EM C2,EM C2,EM C2 C2 ANELBOARD: L -116 -A (NEW MAIN SIZE /TYPE: MLO VOLTS /PHASE: 208Y/120V, 3PH, 4W SECTION: 1 CKT DESCRIPTION NO. 7 9 11 13 15 17 19 21 23 25 27 FRONT EXTERIOR SIGNAGE REAR EXTERIOR SIGNAGE LTG -REAR SALES + EM LTG LTG - MIDDLE SALES + EM LTG LTG -FRONT SALES + EM LTG LTG - SERVICE + EM LTG LTG -PHONE TABLES LTG -"N" TRACK SPARE SPARE SPARE SPACE SPACE SPACE VOLTAMPS PHASE A B C 1,200 ' / / /ii /i SUBTOTAL 2,390 2,250 1,446 12 FAULT CURRENT: REFER TO ONE -LINE DIAGRAM AIC RATING: FCA +10% MINIMUM, FULLY RATED SERVES: FIRST FLOOR MOUNTING: SURFACE LOCATION: BACK AREA, ROOM # :103 WIRE BKR P NO. AMP 20 1 P BKR WIRE AMP NO. 1 2 VOLTAMPS PHASE A B C 180 ' / / / /% // 600 EQUIPMENT GROUND BUS DESCRIPTION /////, RCPT -SHOW WINDOW / /; %i LTG - WHAT'S NEW TRACK 330 LTG -DEMO BAR / 2 LTG -BACK AREA + EM LTG /'2Z CONTRACTORS/TIM ESW ITC H ES 120 CRU- 1 /CU -1 / !11Z RCPT - ROOFTOP UNITS SPARE r -'•f1 SPARE SPARE SPACE / %1, SPACE %1/1 SPACE SPACE SPACE /7 ELECTRIC WATER HEATER (EWH) CKT I NO. 29 31 33 35 37 39 41 SPACE SPACE SPACE SPACE SPACE SPACE SPACE 320 320 / / / /// 576 870 12 12 12 12 20 20 20 20 _ZW1 WA/ INIMA IMINIEMMWASII COMM 20 20 20 20 20 20 20_ 20 20 �iIV/ilit 870 540 11,11111 / / sio 510 -D/ / /// MEN 20 VANIra Fa 120 120 / . PYAWA /2/2/ j %11 RTU -2 5 6 30 i //////• 1,200 / / % / // 1 1 20 1 20 12 1 20 12 1 20 12 1 20 2 30 10 i 20 12 7 20 1 20 1 20 12 20 1 20 1 20 6,904 , / 250 , / :/ /,- 7,968 7,208 , SUBTOTAL C1 C1 EM TOTAL PHASE A - VA AMPS TOTAL PHASE B - VA AMPS TOTAL PHASE C - VA AMPS TOTAL PNLBD - VA AMPS 9,294 77 10,218 85 8,654 72 28,166 78 CONN. VA 10,545 5,960_' 540 5,475 2,996 250 LOAD COOLING HEATING LIGHTING m RECEPTACLES MOTORS SUPP HEAT MISC EQUIP DF 1.00 0 1.25 1.0/.5 1 .00 .00 1 .00 LOAD CONN. VA DF REFRIGERATION SIGN /DISPLAY KITCHEN EXISTING LARGE MOTOR SHOW WINDOW LTG TRACK 1.00 2,400 1.25 1.00 1.00 1.25 2,800 1.25 2,475 1.00 TOTAL DEMAND 36,231 VAI 101 A PANELBOARD NOTES C# - VIA LTG CONTACTOR # EM - EMERG LTG / LOCKABLE TAB LTG TRACK - TRACK LENGT SIGN /DISPLAY - SIGNAGE & DISPLAY CA K O 0 1 - 00:0 cOM? N�c 0 TV CA �FpP�O 0a RECEIVED NOV 14 2007 PERMIT CENTER ABBREVIATIONS �USED N THE DRAWINGS.) A A A/C ACC ACCU ADA AF AFC AFC! AFEA AFF AFG AHJ AHU Al AIC AL AO AP AP ATS AV AWG B BAS BB BD BD BD BDF BFF BFG BFP 61 BKR BO BOD BOP BOS BTU C CAT CATV CD CD CT CCTV CH CFM CKT CMP CMR CP CPT CPVC CRAC CRU CT CTP CU CU CVD CWP DB DDC DI DI DN DPDT DPI DPST DS DS DX (E) EA EAT EDB EF EIA EL EM EMI EMS EMT EPO ER ESFR El EWB EWC EWT FACP FBO FCA FCU FD FD FFA FFB FF EHC A B C+ D E F AMPERES AIR (COMPRESSED) AIR CONDITIONING AIR COOLED CHILLER AIR COOLED CONDENSING UNIT AMERICANS WfTH DISABILITIES ACT AMPERE FUSE ABOVE FINISHED CEILING ARC FAULT CIRCUIT INTERRUPTER AREA FOR EVACUATION ASSISTANCE ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AUTHORITY HAVING JURISDICTION AIR HANDLING UNIT ANALOG INPUT AMPERE INTERRUPTING CURRENT ALUMINUM ANALOG OUTPUT ACCESS PANEL ACCESS POINT AUTOMATIC TRANSFER SWITCH AUDIO VISUAL AMERICAN WIRE GAUGE BOILER BUILDING AUTOMATION FL FLA FLR FU FVNR G GC GE GFCI GFR G GND GPM GRS GYP H HC HD HD HOA HTG HTR HVU HWP HZ 1 IC IE IG IMC IN WC IP ISC ISDN ISP ISP J JB J -BOX K kcmil KK kV kVA kVAR kW kWH L L LAN LAT LCC LDB LEC LED LF LP LRA LWB LWT M M -M MAN MAN MAU MAX MBH MC MCA MCB MCC MD MDF MDP MFR MG MH MH MIN MLO MOCP MPOE MPOP MSB MSWB MS/TP MTD MU N N/A N/C N/O NC NEC NFPA NIC NL NM 0 OA OC ORD 05 OSHA OSP P P PBX PCR FLOW UNE FULL LOAD AMPS FLOOR FURNACE FULL - VOLTAGE, NON- REVERSING GENERAL CONTRACTOR GROUNDING EQUALIZER GROUND FAULT CIRCUIT INTERRUPTER GROUND FAULT RELAY GROUND GROUND GALLONS PER MINUTE GALVANIZED RIGID STEEL GYPSUM BOARD HORIZONTAL CROSS - CONNECT HEAD HUB DRAIN HAND -OFF- AUTOMATIC HEATING HEATER HEATING AND VENTILATING UNIT HEATING WATER PUMP HERTZ INTERMEDIATE CROSS- CONNECT INVERT ELEVATION ISOLATED GROUND INTERMEDIATE METAL CONDUI- INCHES OF WATER COLUMN INTERNET PROTOCOL SHORT CIRCUIT CURRENT INTEGRATED SERVICES DIGITAL NETWORK INTERNET SERVICE PROVIDER INSIDE PLANT CABLE JUNCTION BOX JUNCTION BOX 1000 CIRCULAR MILS KIRK KEY KILOVOLT KILOVOLT -AMPS KILOVOLT -AMPS REACTIVE KILOWATT KILOWATT --HOUR LOUVER LOCAL AREA NETWORK LEAVING AIR TEMPERATURE LIMITED COMBUSTIBLE CABLE LEAVING DRY BULB LOCAL EXCHANGE CARRIER LIGHT- EMITTING DIODE LINEAR FEET LOW PRESSURE LOCKED ROTOR AMPS LEAVING WET BULB LEAVING WATER TEMPERATURE MULTIMODE METROPOLITAN AREA NETWORK MASTER ANTENNA TELEVISION SYSTEM MAKE -UP AIR UNIT MAXIMUM 1000 BTU PER HOUR MAIN CROSS - CONNECT MINIMUM CIRCUIT AMPACITY MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MOTORIZED DAMPER MAIN DISTRIBUTION FRAME MAIN DISTRIBUTION PANEL MANUFACTURER MOTOR GENERATOR MAINTENANCE HOLE MANHOLE MINIMUM MAIN LUGS ONLY MAXIMUM OVERCURRENT PROTECTION MAIN POINT OF ENTRANCE MAIN POINT OF PRESENCE MAIN SWITCHBOARD MAIN SWITCHBOARD MASTER SLAVE/TOKEN PASSING -- COMMUNICATION TRUNK MOUNTED MAKE-UP NOT APPLICABLE NORMALLY CLOSED NORMALLY OPEN NOISE CRITERIA NATIONAL ELECTRICAL CODE NATIONAL FIRE PROTECTION ASSOCIATION. INC. NOT IN CONTRACT NIGHT LIGHT NANO METER OUTSIDE AIR ON CENTER OVERFLOW ROOF DRAIN OCCUPANCY SENSOR OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION OUTSIDE PLANT POLE PRIVATE BRANCH EXHANGE PUMPED CONDENSATE RETURN PDI PLUMBING DRAINAGE INSTITUTE PDU POWER DISTRIBUTION UNIT PH PHASE 0 PHASE PIV POST INDICATOR VALVE PNL PANEL PNLBD PANELBOARD POE POWER OVER ETHERNET POTS STANDARD ANALOG TELEPHONE LINE POTS PLAIN OLD TELEPHONE SERVICE PROVIDE FURNISH AND INSTALL PRV PRESSURE REDUCING VALVE PSTN PUBLIC SWITCHED TELELPHONE NETWORK PT POTENTIAL TRANSFORMER PTP POINT -TO -POINT PTZ PAN, TILT, ZOOM PVC POLYVINYL CHLORIDE Q QTY QUANTITY R RA RETURN AIR RC ROOM CRITERIA RCP REINFORCED CONCRETE PIPE RCPT RECEPTACLE RD ROOF DRAIN RD RETURN DUCT REV REVISION RF RETURN FAN RH RELATIVE HUMIDITY RH ROOF HOOD RHG REFRIGERANT HOT GAS RLA RUNNING LOAD AMPS RMC RIGID METAL CONDUIT RPM REVOLUTIONS PER MINUTE RTU ROOFTOP UNIT RU RACK UNIT S SA SUPPLY AIR SATV SYNCHRONOUS OPTICAL NETWORK SD SMOKE DUCT DETECTOR SD SUPPLY DUCT SF SQUARE FEET SF SUPPLY FAN SPDT SINGLE -POLE. DOUBLE -THROW SPST SINGLE -POLE, SINGLE -THROW SP STATIC PRESSURE SP SUMP PUMP 5S STAINLESS STEEL SS SANITARY SEWER SS SOIL STACK ST SHUNT TRIP ST STEAM TRAP STC SOUND TRANSMISSION CLASS STM STEAM SWBD SWITCHBOARD T TBB TELECOMMUNICATIONS BONDING BACKBONE TBD TO BE DETERMINED TC /C TEMPERATURE CONTROLS CONTRACTOR TDH TOTAL DYNAMIC HEAD TFA TO FLOOR ABOVE TFB TO FLOOR BELOW TGB TELECOMMUNICATIONS GROUND BUS BAR TIA TELECOMMUNICATIONS INDUSTRY ASSOCIATION TL TWISTLOCK TMGB TELECOMMUNICATIONS MAIN GROUND BUS BAR TR TELECOMMUNICATIONS ROOM TT TEMPERATURE TRANSMITTER TWU THROUGH WALL AIR CONDITIONING UNIT TX TRANSFORMER TYP TYPICAL U U/F UNDERFLOOR U / G UNDERGROUND U/S UNDERSLAB UH UNIT HEATER UL UNDERWRITERS LABORATORIES, INC. UNO UNLESS NOTED OTHERWISE UPS UNINTERRUPTIBLE POWER SUPPLY UTP UNSHIELDED TWISTED PAIR V V VOLT(S) VAC VOLTS ALTERNATING CURRENT VD VOLTAGE DROP VDC VOLTS DIRECT CURRENT VAV VARIABLE AIR VOLUME VCP VITRIFIED CLAY PIPE VFD VARIABLE FREQUENCY DRIVE VS VENT STACK VTR VENT THROUGH ROOF W W WIRE W/ WITH W/0 WITHOUT WAN WIDE AREA NETWORK WAP WIRELESS ACCESS POINT WB WET BULB WC WATER COLUMN WG WATER GONG WPD WATER PRESSURE DROP WP WEATHERPROOF WS WASTE STACK WT WATERTIGHT WT WEIGHT X XP EXPLOSION -PROOF SYSTEM BACKBONE BACKDRAFT DAMPER SLOWDOWN BUILDING DISTRIBUTOR BUILDING DISTRIBUTION FRAME BELOW FINISHED FLOOR BELOW FINISHED GRADE BOILER FEED PUMP BINARY INPUT BREAKER BINARY OUTPUT BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM OF STRUCTURE BRITISH THERMAL UNIT CONDUIT CATEGORY CABLE TELEVISION SYSTEM CANDELA CAMPUS DISTRIBUTOR CURRENT TRANSFORMER CLOSED CIRCUIT TELEVISION CHILLER CUBIC FEET PER MINUTE CIRCUIT COMMUNICATIONS PLENUM CABLE COMMUNICATIONS RISER CABLE CONDENSATE PUMP CONTROL POWER TRANSFORMER CHLORINATED POLYVINYL CHLORIDE COMPUTER ROOM AIR CONDITIONING UNIT COMPUTER ROOM UNIT COOLING TOWER COOLING TOWER PUMP COPPER CONDENSING UNIT CUMULATIVE VOLTAGE DROP CHILLED WATER PUMP DECIBELS DIRECT DIGITAL CONTROL DIGITAL INPUT DUCTILE IRON DOWN DOUBLE -POLE, DOUBLE -THROW DIFFERENTIAL PRESSURE INDICATOR DOUBLE -POLE, SINGLE -THROW DOWNSPOUT DUCT SILENCER DIRECT EXPANSION EXISTING EXHAUST AIR ENTERING AIR TEMPERATURE ENTERING DRY BULB EXHAUST FAN ELECTRONIC INDUSTRIES ASSOCATIONS ELECTRIFIED LOCK OR LATCH EMERGENCY ELECTROMAGNETIC INTEFERENCE ENERGY MANAGEMENT SYSTEM ELECTRICAL METALLIC TUBING EMERGENCY POWER OFF EQUIPMENT ROOM EARLY SUPPRESSION FAST RESPONSE EXISTING TO REMAIN ENTERING WET BULB ELECTRIC WATER COOLER ENTERING WATER TEMPERATURE FIRE ALARM CONTROL PANEL FURNISHED BY OTHERS /OWNER FAULT CURRENT AMPS FAN COIL UNIT FLOOR DISTRIBUTOR FLOOR DRAIN FROM FLOOR ABOVE FROM FLOOR BELOW FINISHED FLOOR FIRE HOSE CABINET VOLTS OPERATION BY C1 30 L -116: 1,3,5 L- 116 -A: 4,6 120 TIME SWITCH "TI" PROGRAM INTERIOR ITEMS C2 30 L -116 -A: 5,7,9,11,13,15 120 CONTACTOR SCHEDULE CONTACTOR NUMBER CONTACTOR CONTROL CIRCUIT LOAD DESCRIPTION AMPS CIRCUIT NO. VOLTS OPERATION BY C1 30 L -116: 1,3,5 L- 116 -A: 4,6 120 TIME SWITCH "TI" PROGRAM INTERIOR ITEMS C2 30 L -116 -A: 5,7,9,11,13,15 120 WALL SWITCH INTERIOR LIGHTS C3 30 L- 116 -A: 1,3 120 TIME SWITCH "TE" PROGRAM EXTERIOR ITEMS CONTACTOR NOTES: 1. ALL CONTACTORS SHALL BE NORMALLY OPEN, ELECTRICALLY OPERATED AND ELECTRICALLY HELD. 2. PROVIDE ALL REQUIRED CONTROL ACCESSORIES NECESSARY FOR OPERATION AS DESCRIBED ABOVE. 3. PROVIDE LABELS FOR EACH CONTACTOR /TIME SWITCH INDICATING THE LOAD CONTROLLED. 4. NUMBER ALL WIRES AT EACH CONTACTOR /TIMESWITCH. ELECTRICAL SYMBOLS I NOTE: THIS IS A MASTER LEGEND AND NOT ALL SYMBOLS, ABBREVIATIONS, ETC. ARE NECESSARILY USED ON THE DRAWINGS. POWER EQUIPMENT & DEVICES ELECTRICAL SERVICE PANELBOARD 11MK (SURFACE OR FLUSH MOUNT) = TERMINAL CABINET (SURFACE OR FLUSH MOUNT), TYPE AS NOTED ff: % /ir�1 n TRANSFORMER MOTOR 200/3/150 30/3/15/1 ® 2 VFD B m L TIME SWITCH PHOTOCELL INDICATING LIGHT I-® PUSH BUTTON STOP -START PUSH BUTTON CONTROL STATION ® HAND - OFF --AUTO PUSH BUTTON CONTROL STATION CI MUSHROOM -TYPE PUSH BUTTON PLYWOOD TERMINAL BOARD FOR TELEPHONE SYSTEM, UNO. SIZE AS NOTED. ELECTRICAL DISTRIBUTION PANELBOARD SWITCHBOARD OR MOTOR CONTROL CENTER ON HOUSEKEEPING PAD DISCONNECT SWITCH - "200/3/150" DENOTES AMPERES /POLE /FUSE NF= NON -FUSED CB= CIRCUIT BREAKER (200 /3 /CB) COMBINATION DISCONNECT (SAFETY) SWITCH AND MOTOR STARTER "30/3/15/1" DENOTES AMPERES /POLE /FUSE /NEMA STARTER SIZE NF= NON -FUSED CB= CIRCUIT BREAKER (30/3/X6/1) MAGNETIC MOTOR STARTER, NEMA SIZE AS NOTED. 3-POLE, UNO. MANUAL STARTER VARIABLE FREQUENCY DRIVE RELAY OR CONTACTOR (IN SCHEMATICS) MAGNETIC CONTACTOR, SIZE, COIL VOLTAGE AND NUMBER OF POLES AS INDICATED (L= LIGHTING CONTACTOR, P= POWER CONTACTOR) OVERHEAD PADDLE FAN COMMUNICATIONS LJ`I MJ SC 0 IC 0 AMP SPEAKER HORN PROJECTION TYPE SPEAKER VOLUME CONTROL MICROPHONE JACK COMBINATION SPEAKER /CLOCK SYSTEM CLOCK ELAPSED TIME METER INTERCOM POWER SUPPLY AMPLIFIER TV OUTLET (VIDEO) ANTENNA OUTLET (VIDEO) CABLE N OUTLET (VIDEO) SATELLITE DISH CIRCUITING & WIRING 75 3 P1 OR P1-- -3,5,7 0 1 HOMERUN TO PANELBOARD, ARROWS INDICATE NUMBER OF CIRCUITS, HASH MARKS INDICATE NUMBER OF CONDUCTORS. INFORMATION AT ARROWS ARE CIRCUIT NUMBERS AND PANELBOARD. EQUIPMENT GROUNDING CONDUCTOR IN CONDUIT (GREEN INSULATION OR BARE) ISOLATED GROUNDING CONDUCTOR IN CONDUIT (GREEN INSULATION WITH YELLOW TRACER) CONDUIT CONCEALED CONDUIT IN /UNDER FLOOR /GROUND CONSTRUCTION EXPOSED CONDUIT FLEXIBLE CONDUIT LOW VOLTAGE CABLE CONDUIT TURNING DOWN CONDUIT TURNING UP CONNECTION POINT OR EQUIPMENT TERMINATION EQUIPMENT TERMINATION WIRING DEVICES & OUTLETS SINGLE POLE WALL SWITCH (NO LETTER DESIGNATION) (0, CEILING MOUNTED OCCUPANCY SENSOR WITH POWER SUPPLY J AND LOAD RELAY AS REQUIRED OR SPECIFIED. 6 05 RECEPTACLE INSTALLED VIA DROP CORD 6 GFCI RECEPTACLE LETTER DESIGNATIONS AS FOLLOWS: C = CLOCK HANGER TYPE E = EMERGENCY POWER S - SWITCHED IG = ISOLATED GROUND GFCI = GROUND FAULT CIRCUIT INTERRUPTER WP = WEATHERPROOF • e TELEPHONE OUTLET - FLOOR OR WALL MOUNTED. INSTALL 0 AT SAME ELEVATION AS ADJACENT RECEPTACLE, UNO. DATA OUTLET - FLOOR OR WALL MOUNTED. INSTALL AT • SAME ELEVATION AS ADJACENT RECEPTACLE, UNO. MULTI - SERVICE OUTLET; TELEPHONE AND DATA -- FLOOR OR ® • WALL MOUNTED. INSTALL AT SAME ELEVATION AS ADJACENT RECEPTACLE, UNO. 0 A ®A O A 0 O 0 ESR SWITCH LETTER DESIGNATIONS AS FOLLOWS: 2 = TWO POLE WALL SWITCH 3 = THREE -WAY WALL SWITCH 4 = FOUR -WAY WALL SWITCH D = DIMMER TYPE SWITCH OS - OCCUPANCY SENSOR P = SPST PILOT LIGHT SWITCH K = KEYED LIGHT SWITCH M = MOTOR RATED SWITCH SIMPLEX RECEPTACLE - NEMA 5 -20R, UNO DUPLEX RECEPTACLE - NEMA 5 -20R, UNO DOUBLE DUPLEX RECEPTACLE - NEMA 5 -20R, UNO HEAVY DUTY RECEPTACLE - NEMA TYPE AS NOTED TWIST -LOCK TYPE RECEPTACLE RECEPTACLE INSTALLED 6" ABOVE COUNTER OR BACKSPLASH CEILING MOUNTED DUPLEX RECEPTACLE FLOOR MOUNTED DUPLEX RECEPTACLE ISOLATED GROUND (DUPLEX RECEPTACLE, SIMILAR FOR OTHERS) EMERGENCY POWER (DUPLEX RECEPTACLE, SIMILAR FOR OTHERS) MULTI - OUTLET SURFACE RACEWAY WITH NEMA 5 -20R RECEPTACLES 12" ON CENTER, UNO. MULTI- SERVICE POWER POLE WITH TELEPHONE, DATA AND POWER OUTLETS A = TYPE, SEE SCHEDULE IN SPECIFICATIONS MULTI-SERVICE FLOOR BOX WITH TELEPHONE, DATA AND POWER OUTLETS A - TYPE, SEE SCHEDULE IN SPECIFICATIONS POKE THROUGH, A = TYPE, SEE SCHEDULE IN SPECIFICATIONS THERMOSTAT JUNCTION BOX /OUTLET BOX JUNCTION BOX /OUTLET BOX EMERGENCY SHUNT RELAY LIGHTING A 1 F�7 ■• A V 'V 1 7 0 0 0 0 o A Q gQ ® A A 0) A © a FLUORESCENT LIGHT FIXTURE: (SEE LIGHT FIXTURE SCHEDULE) a = SWITCHED BY SWITCH "a" A = LIGHT FIXTURE TYPE "A" FLUORESCENT LIGHT FIXTURE WITH NIGHT LIGHT FLUORESCENT LIGHT FIXTURE WITH EMERGENCY LIGHTING BATTERY PACK FLUORESCENT LIGHT FIXTURE WITH DUAL BALLASTS CIRCUITED SEPARATELY. (SHADING IMPLIES EMERGENCY BALLAST WITH BATTERY PACK) LIGHTING TRACK WITH LIGHT FIXTURE TYPES AS INDICATED MIRROR LIGHTS (SEE LIGHT FIXTURE SCHEDULE) LIGHT FIXTURE - CEILING / WALL MOUNTED. A = LIGHT FIXTURE TYPE "A" WALL WASHER LICHT FIXTURE - ARROW INDICATES DIRECTION. A = LIGHT FIXTURE TYPE "A" WALL MOUNTED LIGHT FIXTURE. A = LIGHT FIXTURE TYPE "A" SITE LIGHTING FIXTURE (SEE LIGHT FIXTURE SCHEDULE) EXIT SIGN - CEILING / WALL MOUNTED, ARROWS AS INDICATED. A = LIGHT FIXTURE TYPE "A" (SEE LIGHT FIXTURE SCHEDULE) A �pEMERGENCY BATTERY PACK LIGHT FIXTURE - CEILING /WALL u MOUNTED. (SEE LIGHT FIXTURE SCHEDULE) AFEA (AREA FOR EVACUATION ASSISTANCE) SIGN - CEILING /WALL EJ MOUNTED, ARROWS AS INDICATED, A = LIGHT FIXTURE TYPE "A" (SEE LIGHT FIXTURE SCHEDULE) D SWITCH FOR TIME SWITCH OVERRIDE. ,I- SINGLE GANG DEVICE BOX & SWITCH WITH HUBBEL SWITCH LOCK -OUT DEVICE #: 'HSLD'. FLIP LOCK -OUT DEVICE UPSIDE DOWN TO ALLOW SWITCH TO BE LOCKED IN THE ON POSITION. TYPICAL CONTACTOR CONTROL () SWITCH C PLATE ELEVATION NO SCALE 120 VAC, TOGGLE SWITCH LOCATE AT MASTER SWITCH LOCATION. (RE: 1/E2) RE: PANELBOARD SCHEDULES FOR CIRCUIT NUMBER. RE: PANELBOARD SCHEDULES FOR CIRCUIT NUMBER. BRANCH CIRCUITS OUT TO LOAD. RE: PANELBOARD SCHEDULES b S N {/V TIMESWITCH "TE" MOUNTED BY PANELBOARD BRANCH CIRCUITS OUT TO LOAD. RE: PANELBOARD SCHEDULES TIMESWITCH "TI" MOUNTED BY PANELBOARD RE: PANELBOARD SCHEDULES FOR CIRCUIT NUMBER. BRANCH CIRCUITS OUT TO LOAD. RE: PANELBOARD SCHEDULES TIMESWITCH "TI" WIRING DIAGRAM NO SCALE "C2" I 0 II 0 y I I I I t-1 I95 "C3" 0 0 0 BRANCH CIRCUITS FROM PANELBOARD CONTACTOR "C2" WIRING DIAGRAM NO SCALE BRANCH CIRCUITS FROM PAN ELBOARD CONTACTOR "C3" WIRING DIAGRAM NO SCALE f < "C1" .I - I , II -1 II 10 RECEIVED NOV 14 2007 PERMIT CENTER w 0_ Q LL w 07 Cf) O I n 0 N 0 O O d 0 cn 0 E E 0 C.) 0 ca rn 7D w 0 v ci co 0 0 0 0 0 Ci) w J W Ct Z 0 N W 5 uJ co Q Q 00 r W ct � z w Q 0 w 0 I G7 0 0 0 12/08/08 W CD to J oZi PRQJ. 2007 -0174 DRWN. EC DATE 9 -25 -07 E4 24 OF 27 REAR OF DESK Q POWER FEED DIAGRAM AT TECH SERVICE DESKS NOT TO SC (1) 1 -1/2 CONDUIT TO 6" ABOVE SUSP. CEILING W /PULL STRING. SEE ELECTRICAL PLAN FOR DETAIL COMMUNICATION COVER PLATE FOR DATA (1) 1 -1/2 "0 OR (1) 2" 0 CONDUIT TO 6" ABOVE SUSP. CEILING W /PULL STRING. SEE ELECTRICAL PLAN FOR DETAIL COMMUNICATION COVER PLATE FOR DATA FLOOR BOX '1A' AND '1B' FLOOR BOX '2A' AND '2B' SECTION THRU DESK (2) FLUSH DUPLEX OUTLETS. FLOOR BOX DETAILS NOT TO SCALE (2) QUAD OUTLETS PER P.O.S. MODULE BY MILLWORK VENDOR FRONT OF DESK 1 1/2" 0 CONDUIT TO 6" ABOVE SUSPENDED CEILING WITH PULL STRING FOR PHONE /DATA 5 -WIRE POWER TRANSUION UNIT RECESSED IN WALL REMOVABLE PANEL FOR WIRE ACCESS 1 "0 CONDUfTS FOR POWER. 1 "0 CONDUITS FOR POWER. (2) FLUSH DUPLEX OUTLETS. r 7 1 1 .J L O DATA CONDUIT r FIXTURE AND OUTLETS "WHAT'S NEW" WALL FIOS FIXTURE POWER DIAGRAM NOT TO SCALE LINE OF SUSPENDED TILE CEILING ADA COUNTER RECEPTACLE VIA 11ME SWITCH "TI" FOR FIXTURE LIGHTING REQUIREMENTS UNSWITCHED QUAD POWER OUTLET FOR FIXTURE CONDUIT FOR DATA. DATA BY VERIZON WIRELESS LINE OF FINISHED FLOOR REAR OF COUNTER SECTION THRU ADA COUNTER OPEN ACCESS CHANNEL FOR RUNNING DATA/ POWER ONES DATA UNE THRU ACCESS C SALES DESK 1 1/2" 0 CONDUIT TO 6" ABOVE SUSPENDED CEIUNG WITH PULL STRING FOR PHONE /DATA POWER FEED DIAGRAM AT SALES DESKS NOT TO SCALE 5 -WIRE POWER ENTRY CABLE ASSEMBLIES THRU ACCESS CHANNEL TO SALES DESK / / / / / / / //C / / / / / /// / / //I / I / / ! // /I i PLAN 4' -fi" ELEVATION 1 -0 4 '- FRONT OF COUNTER UNE OF SUSPENDED • 11LE CEILING DATA CONDUIT UNE OF FINISHED FLOOR DATA CONDUIT "MY ACCOUNT" FIXTURE POWER DIAGRAM NOT TO SCALE PLUGMOLD DETAIL NOT TO SCALE SOLUTION WALL POWER DIAGRAM (RIGHT FACING) NOT TO SCALE UNE OF SUSPENDED TILE CEILING UNE OF FINISHED FLOOR CONTINUOUS PLUGMOLD WITH OUTLETS AT 6" O.C. WIREMOLD 2000 SERIES #G20GB606 (L -1 FINISH), OR APPROVED EQUAL (LENGTH AS REQUIRED) COUNTER AND CABINETRY, TYP. 1" DATA CONDUIT 2' -0" PHONE TABLE POWER DIAGRAM NOT TO SCALE EQ. EQ. i r a I 0 N (FOR DATA WIRING) BUSHING f 4" CONDUIT, SEE PLANS FOR SIZE AND LOCATION. SUSP. CLG. BUSHING THRU- CEILING CONDUIT DETAIL NOT TO SCALE QUEUE SCREEN WALL POWER DIAGRAM NOT TO SCALE UNE OF SUSPENDED TILE CEILING RECESS IN WAIL FOR MONITOR & VESA MOUNT LINE OF FINISHED FLOOR 5 w 0 rn MONITOR PROVIDED BY VERIZON WIRELESS UNE OF PEERLESS ARTICULATING WALL ARM; MODEL # SA740P LOCATION OF POWER AND DATA 1 DATA CONDUIT FLOOR CUSTOMER CHECK-IN POWER DIAGRAM NOT TO SCALE PULL STRING TYP. DATA PULL STRING DETAIL NOT TO SCALE (FOR DATA WIRING) (RE SYMBOLS LEGEND SHEET E4.0) SUSP. CLG. CONDUIT AS REQUIRED ELECTRICAL BOX r F N C W 0 DISPLAY FIXTURE FIXTURE AND OUTLETS EQ. DATA CONDUIT EQ. I PROMO WALL /"WHAT'S NEW" WALL FIXTURE POWER DIAGRAM NOT TO SCALE DEMO BAR POWER DIAGRAM NOT TO SCALE 4. LINE OF SUSPENDED TILE CEILING DATA CONDUIT LINE OF FINISHED FLOOR BILL PAYMENT MACHINE AND VZTV POWER DIAGRAM NOT TO SCALE UNE OF SUSPENDED TILE CEILING J 2" DATA CONDUIT LINE OF FINISHED FLOOR MONITOR PROVIDED BY VERIZON WIRELESS UNE OF PEERLESS ARTICULATING WALL ARM; MODEL # SA740P LOCATION OF POWER AND DATA ' L .D OCT 1 5 FO7 PEr r,;ll I CLiN I EF J QQ co W _.. !r PROJ. 2007 -0174 DRWN. EC DATE 9 -25 -07 5 25 OF 27 / REAR OF DESK Q POWER FEED DIAGRAM AT TECH SERVICE DESKS NOT TO SC (1) 1 -1/2 CONDUIT TO 6" ABOVE SUSP. CEILING W /PULL STRING. SEE ELECTRICAL PLAN FOR DETAIL COMMUNICATION COVER PLATE FOR DATA (1) 1 -1/2 "0 OR (1) 2" 0 CONDUIT TO 6" ABOVE SUSP. CEILING W /PULL STRING. SEE ELECTRICAL PLAN FOR DETAIL COMMUNICATION COVER PLATE FOR DATA FLOOR BOX '1A' AND '1B' FLOOR BOX '2A' AND '2B' SECTION THRU DESK (2) FLUSH DUPLEX OUTLETS. FLOOR BOX DETAILS NOT TO SCALE (2) QUAD OUTLETS PER P.O.S. MODULE BY MILLWORK VENDOR FRONT OF DESK 1 1/2" 0 CONDUIT TO 6" ABOVE SUSPENDED CEILING WITH PULL STRING FOR PHONE /DATA 5 -WIRE POWER TRANSUION UNIT RECESSED IN WALL REMOVABLE PANEL FOR WIRE ACCESS 1 "0 CONDUfTS FOR POWER. 1 "0 CONDUITS FOR POWER. (2) FLUSH DUPLEX OUTLETS. r 7 1 1 .J L O DATA CONDUIT r FIXTURE AND OUTLETS "WHAT'S NEW" WALL FIOS FIXTURE POWER DIAGRAM NOT TO SCALE LINE OF SUSPENDED TILE CEILING ADA COUNTER RECEPTACLE VIA 11ME SWITCH "TI" FOR FIXTURE LIGHTING REQUIREMENTS UNSWITCHED QUAD POWER OUTLET FOR FIXTURE CONDUIT FOR DATA. DATA BY VERIZON WIRELESS LINE OF FINISHED FLOOR REAR OF COUNTER SECTION THRU ADA COUNTER OPEN ACCESS CHANNEL FOR RUNNING DATA/ POWER ONES DATA UNE THRU ACCESS C SALES DESK 1 1/2" 0 CONDUIT TO 6" ABOVE SUSPENDED CEIUNG WITH PULL STRING FOR PHONE /DATA POWER FEED DIAGRAM AT SALES DESKS NOT TO SCALE 5 -WIRE POWER ENTRY CABLE ASSEMBLIES THRU ACCESS CHANNEL TO SALES DESK / / / / / / / //C / / / / / /// / / //I / I / / ! // /I i PLAN 4' -fi" ELEVATION 1 -0 4 '- FRONT OF COUNTER UNE OF SUSPENDED • 11LE CEILING DATA CONDUIT UNE OF FINISHED FLOOR DATA CONDUIT "MY ACCOUNT" FIXTURE POWER DIAGRAM NOT TO SCALE PLUGMOLD DETAIL NOT TO SCALE SOLUTION WALL POWER DIAGRAM (RIGHT FACING) NOT TO SCALE UNE OF SUSPENDED TILE CEILING UNE OF FINISHED FLOOR CONTINUOUS PLUGMOLD WITH OUTLETS AT 6" O.C. WIREMOLD 2000 SERIES #G20GB606 (L -1 FINISH), OR APPROVED EQUAL (LENGTH AS REQUIRED) COUNTER AND CABINETRY, TYP. 1" DATA CONDUIT 2' -0" PHONE TABLE POWER DIAGRAM NOT TO SCALE EQ. EQ. i r a I 0 N (FOR DATA WIRING) BUSHING f 4" CONDUIT, SEE PLANS FOR SIZE AND LOCATION. SUSP. CLG. BUSHING THRU- CEILING CONDUIT DETAIL NOT TO SCALE QUEUE SCREEN WALL POWER DIAGRAM NOT TO SCALE UNE OF SUSPENDED TILE CEILING RECESS IN WAIL FOR MONITOR & VESA MOUNT LINE OF FINISHED FLOOR 5 w 0 rn MONITOR PROVIDED BY VERIZON WIRELESS UNE OF PEERLESS ARTICULATING WALL ARM; MODEL # SA740P LOCATION OF POWER AND DATA 1 DATA CONDUIT FLOOR CUSTOMER CHECK-IN POWER DIAGRAM NOT TO SCALE PULL STRING TYP. DATA PULL STRING DETAIL NOT TO SCALE (FOR DATA WIRING) (RE SYMBOLS LEGEND SHEET E4.0) SUSP. CLG. CONDUIT AS REQUIRED ELECTRICAL BOX r F N C W 0 DISPLAY FIXTURE FIXTURE AND OUTLETS EQ. DATA CONDUIT EQ. I PROMO WALL /"WHAT'S NEW" WALL FIXTURE POWER DIAGRAM NOT TO SCALE DEMO BAR POWER DIAGRAM NOT TO SCALE 4. LINE OF SUSPENDED TILE CEILING DATA CONDUIT LINE OF FINISHED FLOOR BILL PAYMENT MACHINE AND VZTV POWER DIAGRAM NOT TO SCALE UNE OF SUSPENDED TILE CEILING J 2" DATA CONDUIT LINE OF FINISHED FLOOR MONITOR PROVIDED BY VERIZON WIRELESS UNE OF PEERLESS ARTICULATING WALL ARM; MODEL # SA740P LOCATION OF POWER AND DATA ' L .D OCT 1 5 FO7 PEr r,;ll I CLiN I EF SECTION 16A GENERAL ELECTRICAL REQUIREMENTS: 16A 1 GENERAL INSTRUCTIONS 16A 1 -1 GENERAL REQUIREMENTS ALL REQUIREMENTS UNDER DMSION 1 AND THE GENERAL AND SUPPLEMENTARY CONDITIONS OF THESE SPECIFICATIONS APPLY TO THIS SECTION AND DIVISION, WHERE THE REQUIREMENTS OF THIS SECTION AND DIVISION EXCEED THOSE OF DMSION 1, THIS SECTION AND DIVISION TAKE PRECEDENCE. BECOME THOROUGHLY FAMILIAR WITH ALL THEIR CONTENTS AS TO REQUIREMENTS THAT AFFECT THIS DIVISION, SECTION OR BOTH. WORK REQUIRED UNDER THIS DIVISION INCLUDES ALL MATERIAL EQUIPMENT, APPLIANCES, AND LABOR REQUIRED TO COMPLETE THE ENTIRE ELECTRICAL SYSTEM AS REQUIRED BY THE DRAWINGS AND SPECIFICATIONS, OR REASONABLY INFERRED TO BE NECESSARY TO FACILITATE EACH SYSTEM'S FUNCTIONING AS IMPLIED BY THE DESIGN AND THE EQUIPMENT SPECIFIED. THE SPECIFICATIONS AND DRAWINGS FOR THE PROJECT ARE COMPLEMENTARY, AND PORTIONS OF THE WORK DESCRIBED IN ONE, SHALL BE PROVIDED AS IF DESCRIBED IN BOTH. IN THE EVENT OF DISCREPANCIES, NOTIFY THE ENGINEER AND REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH THE WORK INVOLVED. DRAWINGS ARE GRAPHIC REPRESENTATIONS OF THE WORK UPON WHICH THE CONTRACT IS BASED. THEY SHOW THE MATERIALS AND THEIR RELATIONSHIP TO ONE ANOTHER, INCLUDING SIZES, SHAPES, LOCATIONS, AND CONNECTIONS. THEY ALSO CONVEY THE SCOPE OF WORK, INDICATING THE INTENDED GENERAL ARRANGEMENT OF THE EQUIPMENT, FIXTURES, OUTLETS AND CIRCUITS WITHOUT SHOWING ALL OF THE EXACT DETAILS AS TO ELEVATIONS, OFFSETS, CONTROL LINES, AND OTHER INSTALLATION REQUIREMENTS. USE THE DRAWINGS AS A GUIDE WHEN LAYING OUT THE WORK AND TO VERIFY THAT MATERIALS AND EQUIPMENT WILL FIT INTO THE DESIGNATED SPACES, AND WHICH, WHEN INSTALLED PER MANUFACTURERS' REQUIREMENTS, WILL ENSURE A COMPLETE, COORDINATED, SATISFACTORY AND PROPERLY OPERATING SYSTEM. DRAWINGS ARE SCHEMATIC IN NATURE, SHOW THE VARIOUS COMPONENTS OF THE SYSTEMS APPROXIMATELY TO SCALE AND ATTEMPT TO INDICATE HOW THEY SHALL BE INTEGRATED WITH OTHER PARTS OF THE WORK. FIGURED DIMENSIONS TAKE PRECEDENCE TO SCALED DIMENSIONS. DETERMINE EXACT LOCATIONS BY JOB MEASUREMENTS, BY CHECKING THE REQUIREMENTS OF OTHER TRADES, AND BY REVIEWING ALL CONTRACT DOCUMENTS. CORRECT ERRORS THAT COULD HAVE BEEN AVOIDED BY PROPER CHECKING AND INSPECTION, AT NO ADDITIONAL COST TO THE OWNER. SPECIFICATIONS DEFINE THE QUALITATIVE REQUIREMENTS FOR PRODUCTS. MATERIALS, AND WORKMANSHIP UPON WHICH THE CONTRACT IS BASED. 16A 1 -2 DEFINITIONS WHENEVER USED IN THESE SPECIFICATIONS OR DRAWINGS, THE FOLLOWING TERMS SHALL HAVE THE INDICATED MEANINGS: 1. FURNISH: "TO SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBUNG, INSTALLING, AND SIMILAR OPERATIONS." 2. INSTALL ' PERFORM ALL OPERATIONS AT THE PROJECT SITE, INCLUDING, BUT NOT LIMITED TO, AND AS REQUIRED: UNLOADING, UNPACKING, ASSEMBUNG, ERECTING, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, TESTING, COMMISSIONING, STARTING UP AND SIMILAR OPERATIONS, COMPLETE, AND READY FOR THE INTENDED USE." 3. PROVIDE: "TO FURNISH AND INSTALL COMPLETE, AND READY FOR THE INTENDED USE." 4. FURNISHED BY OWNER (OR OWNER - FURNISHED) OR FURNISHED BY OTHERS: AN ITEM FURNISHED BY THE OWNER OR UNDER OTHER DMSIONS OR CONTRACTS, AND INSTALLED UNDER THE REQUIREMENTS OF THIS DIVISION, COMPLETE, AND READY FOR THE INTENDED USE, INCLUDING ALL ITEMS AND SERVICES INCIDENTAL TO THE WORK NECESSARY FOR PROPER INSTALLATION AND OPERATION. INCLUDE THE INSTALLATION UNDER THE WARRANTY REQUIRED BY THIS DIVISION. 5. ENGINEER: WHERE REFERENCED IN THIS DIVISION, "ENGINEER" IS THE ENGINEER OF RECORD AND THE DESIGN PROFESSIONAL FOR THE WORK UNDER THIS DIVISION, AND IS A CONSULTANT TO, AND AN AUTHORIZED REPRESENTATIVE OF, THE ARCHITECT, AS DEFINED IN THE GENERAL AND /OR SUPPLEMENTARY CONDITIONS. WHEN USED IN THIS DIVISION, IT MEANS INCREASED INVOLVEMENT BY, AND OBLIGATIONS TO, THE ENGINEER, IN ADDITION TO INVOLVEMENT BY, AND OBLIGATIONS TO, THE "ARCHITECT ". 6. AHJ: THE LOCAL CODE AND /OR INSPECTION AGENCY (AUTHORITY) HAVING JURISDICTION OVER THE WORK. 7. NRTL: NATIONALLY RECOGNIZED TESTING LABORATORY, AS DEFINED AND LISTED BY OSHA IN 29 CFR 1910.7 (E.G., UL, ETL, CSA), AND ACCEPTABLE TO THE AHJ OVER THIS PROJECT. 8. THE TERMS "APPROVED EQUAL ", "EQUIVALENT ", OR "EQUAL" ARE USED SYNONYMOUSLY AND SHALL MEAN "ACCEPTED BY OR ACCEPTABLE TO THE ENGINEER AS EQUIVALENT TO THE ITEM OR MANUFACTURER SPECIFIED ". THE TERM "APPROVED" SHALL MEAN LABELED, LISTED, CERTIFIED, OR ALL THREE, BY AN NRTL, AND ACCEPTABLE TO THE AHJ OVER THIS PROJECT. 16A 1 -3 PRE -BID SITE VISIT PERSONALLY INSPECT THE SITE OF THE PROPOSED WORK AND BECOME FULLY INFORMED OF CONDITIONS UNDER WHICH THE WORK 15 TO BE DONE. FAILURE TO DO 50 WILL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO REQUEST OR OBTAIN EXTRA COMPENSATION OVER AND ABOVE THE CONTRACT PRICE. 16A 1 -4 MATERIAL AND WORKMANSHIP PROVIDE ALL MATERIAL AND EQUIPMENT NEW AND IN FIRST CLASS CONDITION. PROVIDE MARKINGS OR A NAMEPLATE FOR ALL MATERIAL AND EQUIPMENT IDENTIFYING THE MANUFACTURER AND PROVIDING SUFFICIENT REFERENCE TO ESTABLISH QUALITY, SIZE AND CAPACITY. ALL WORKMANSHIP SHALL BE OF THE FINEST POSSIBLE BY EXPERIENCED MECHANICS OF THE PROPER TRADE. IN GENERAL, PROVIDE THE FOLLOWING QUALITY GRADE(S) FOR ALL MATERIALS AND EQUIPMENT LIGHT DUTY AND RESIDENTIAL TYPE EQUIPMENT WILL NOT BE ACCEPTABLE: 1. COMMERCIAL SPECIFICATION GRADE PROVIDE ALL HOISTS, SCAFFOLDS, STAGING, RUNWAYS, TOOLS, MACHINERY AND EQUIPMENT REQUIRED FOR THE PERFORMANCE OF THE ELECTRICAL WORK. STORE AND MAINTAIN MATERIAL AND EQUIPMENT IN CLEAN CONDITION, AND PROTECTED FROM WEATHER, MOISTURE, AND PHYSICAL DAMAGE. FURNISH ONLY MATERIAL AND EQUIPMENT THAT ARE LISTED, LABELED. CERTIFIED, OR ALL THREE, BY A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL), WHENEVER ANY USTING OR LABELING EXISTS FOR THE TYPES OF MATERIAL AND EQUIPMENT SPECIFIED. AT A MINIMUM, GENERAL WORK PRACTICES FOR ELECTRICAL CONSTRUCTION SHALL BE IN ACCORDANCE WITH NECA 1 (LATEST EDITION), "STANDARD PRACTICES FOR GOOD WORKMANSHIP IN ELECTRICAL CONSTRUCTION ". 16A 1 -5 MANUFACTURERS IN OTHER ARTICLES WHERE USTS OF MANUFACTURERS ARE INTRODUCED, SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE MANUFACTURERS SPECIFIED. WHERE A UST IS PROVIDED, MANUFACTURERS ARE LISTED ALPHABETICALLY AND NOT IN ACCORDANCE WITH ANY RANKING OR PREFERENCE. WHERE MANUFACTURERS ARE NOT LISTED, PROVIDE PRODUCTS SUBJECT TO COMPLIANCE WITH REQUIREMENTS FROM MANUFACTURERS THAT HAVE BEEN ACTIVELY INVOLVED IN MANUFACTURING THE SPECIFIED PRODUCT FOR NO LESS THAN 5 YEARS. 16A 1 -6 COORDINATION COORDINATE ALL WORK WITH OTHER DIVISIONS AND TRADES 50 THAT VARIOUS COMPONENTS OF THE ELECTRICAL SYSTEMS ARE INSTALLED AT THE PROPER TIME, FIT THE AVAILABLE SPACE, AND ALLOW PROPER SERVICE ACCESS TO ALL EQUIPMENT. REFER TO ALL DRAWINGS, INCLUDING, BUT NOT LIMITED TO, CIVIL, ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND PLUMBING, AND TO RELEVANT EQUIPMENT SUBMITTALS AND SHOP DRAWINGS TO DETERMINE THE EXTENT OF CLEAR SPACES. MAKE ALL OFFSETS REQUIRED TO CLEAR EQUIPMENT, BEAMS AND OTHER STRUCTURAL MEMBERS, AND TO FACILITATE CONCEALING RACEWAYS IN THE MANNER ANTICIPATED IN THE DESIGN. PROVIDE MATERIALS WITH TRIM THAT WILL FIT PROPERLY THE TYPES OF CEILING, WALL, OR FLOOR FINISHES ACTUALLY INSTALLED 16A 1-7 ORDINANCES CODES. AND STANDARDS COMPLY. AT A MINIMUM, WITH NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) STANDARDS, STATE AND LOCAL BUILDING CODES, AND ALL OTHER APPLICABLE CODES AND ORDINANCES FOR PERFORMANCE, WORKMANSHIP, EQUIPMENT, AND MATERIALS. ADDITIONALLY, COMPLY WITH RULES AND REGULATIONS OF PUBUC UTILITIES AND MUNICIPAL DEPARTMENTS AFFECTED BY CONNECTION OF SERVICES. WHERE CONFLICTS BETWEEN VARIOUS CODES, ORDINANCES, RULES, AND REGULATIONS DCIST, COMPLY WITH THE MOST STRINGENT. WHEREVER REQUIREMENTS OF THESE SPECIFICATIONS, DRAWINGS, OR BOTH, EXCEED THOSE OF THE ABOVE ITEMS, THE REQUIREMENTS OF THESE SPECIFICATIONS, DRAWINGS, OR BOTH, SHALL GOVERN. CODE COMPLIANCE, AT A MINIMUM, IS MANDATORY. CONSTRUE NOTHING IN THESE CONSTRUCTION DOCUMENTS AS PERMITTING WORK NOT IN COMPLIANCE, AT A MINIMUM, WITH THESE CODES. BRING ALL CONFLICTS OBSERVED BETWEEN CODES, ORDINANCES, RULES, REGULATIONS, REFERENCED STANDARDS, AND THESE DOCUMENTS TO THE ENGINEER'S ATTENTION FOR FINAL RESOLUTION. CONTRACTOR WILL BE HELD RESPONSIBLE FOR ANY VIOLATION OF THE LAW. PROVIDE AND MAINTAIN ALL NECESSARY SIGNAL LIGHTS AND GUARDS FOR THE SAFETY OF THE PUBLIC. OBTAIN AND PAY FOR ALL PERMITS FOR WORK IN THIS DMSION. 16A 1 -8 PROTECTION OF EQUIPMENT AND MATERIALS STORE AND PROTECT FROM DAMAGE EQUIPMENT AND MATERIALS DELIVERED TO JOB SITE, IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. FOR MATERIALS AND EQUIPMENT SUSCEPTIBLE TO CHANGING WEATHER CONDITIONS, DAMPNESS, OR TEMPERATURE VARIATIONS, STORE INSIDE IN CONDITION SPACES. FOR MATERIALS AND EQUIPMENT NOT SUSCEPTIBLE TO THESE CONDITIONS, COVER WITH WATERPROOF, TEAR - RESISTANT, HEAVY TARP OR POLYETHYLENE PLASTIC AS REQUIRED TO PROTECT FROM PLASTER, DIRT, PAINT, WATER, OR PHYSICAL DAMAGE. EQUIPMENT AND MATERIAL THAT HAS BEEN DAMAGED BY CONSTRUCTION ACTIVITIES WILL BE REJECTED, AND CONTRACTOR SHALL FURNISH NEW EQUIPMENT AND MATERIAL OF A LIKE KIND. PLUG OR CAP OPEN ENDS OF CONDUITS WHILE STORED AND INSTALLED DURING CONSTRUCTION WHEN NOT IN USE TO PREVENT THE ENTRANCE OF DEBRIS INTO THE SYSTEMS. 16A 1 -9 SUBSTITUTIONS INCLUDE IN THE BASE BID THE PRODUCTS SPECIFICALLY NAMED IN THESE SPECIFICATIONS OR ON THE DRAWINGS. SUBMIT, IN THE FORM OF ALTERNATES, WITH BID, PRODUCTS OF ANY OTHER MANUFACTURERS FOR SIMILAR USE, PROVIDED THE DIFFERENCES IN COST, IF ANY, ARE INCLUDED FOR EACH PROPOSED ALTERNATE. PRIOR TO THE BID DATE. SUBSTITUTIONS WILL NOT BE CONSIDERED UNLESS SUBMITTED TO THE ARCHITECT, FOR REVIEW, AT LEAST TEN CALENDAR DAYS PRIOR TO THE DATE FOR RECEIPT OF BIDS. INCLUDE THE NAME OF THE MATERIAL OR EQUIPMENT FOR WHICH IT I5 TO BE SUBSTITUTED AND A COMPLETE DESCRIPTION OF THE PROPOSED SUBSTITUTE INCLUDING CUTSHEETS, PHOTOMETRIC DATA, AND ALL OTHER INFORMATION NECESSARY FOR AN EVALUATION FOR EACH SUCH REQUEST. PROVIDE FACTORY GENERATED POINT -BY- POINT CALCULATIONS FOR ALL EXTERIOR LIGHT FIXTURES (PHOTOMETRIC FILES SUPPLIED 50 THE ENGINEER CAN GENERATE A POINT -BY -POINT DO NOT SUFFICE FOR THE POINT -BY- POINT CALCULATIONS). PROVIDE INTERIOR POINT -BY -POINT CALCULATIONS AT THE DISCRETION OF THE ENGINEER. SUBMIT A $100.00 REVIEW FEE TO THE ENGINEER WITH EACH SUCH POINT -BY -POINT CALCULATION FOR USE OF ELECTRONIC BASE FILES. AFTER THE BID DATE, PROPOSALS TO SUBSTITUTE UGHT FIXTURES FOR THOSE SHOWN ON THE DRAWINGS OR SPECIFIED HEREIN, WILL ONLY BE CONSIDERED AS A DEDUCT. SUBMIT PROPOSED SUBSTITUTIONS SEPARATELY, IN SUBMITTAL FORM, WITH A UST OF PROPOSED SUBSTITUTIONS TOGETHER WITH A DEDUCT PRICE FOR EACH SUBSTITUTION. THE ARCHITECT, ENGINEER, OR BOTH, WILL THEN REVIEW PROPOSED SUBSTITUTIONS. THE ENGINEER WILL HAVE THE FINAL AUTHORITY AS TO WHETHER THE LIGHT FIXTURE IS AN ACCEPTABLE REPLACEMENT TO THE SPECIFIED ITEM. THE PROPOSED SUBSTITUTION MAY ALSO BE REJECTED BY THE ARCHITECT FOR AESTHETIC REASONS IF FELT NECESSARY OR DESIRABLE. IN THE EVENT THE PROPOSED SUBSTITUTIONS HEREIN DESCRIBED ARE REJECTED, FURNISH THE SPECIFIED ITEM. 16A 1 -10 ELECTRONIC DRAWING FILES IN PREPARATION OF SHOP DRAWINGS, CONTRACTOR MAY, AS AN OPTION, OBTAIN ELECTRONIC DRAWING FILES IN AUTOCAD OR DXF FORMAT FROM THE ENGINEER FOR A SHIPPING AND HANDLING FEE OF $200 FOR A DRAWING SET UP TO 12 SHEETS AND $15 PER SHEET FOR EACH ADDITIONAL SHEET. CONTACT THE ARCHITECT FOR WRITTEN AUTHORIZATION; AND. CONTACT THE ENGINEER TO OBTAIN THE NECESSARY RELEASE AGREEMENT FORM AND TO INDICATE THE DESIRED SHIPPING METHOD AND DRAWING FORMAT. IF A 100 MB ZIP DISK OR CD -ROM IS DESIRED, ADD THE APPROPRIATE CHARGE INDICATED. IN ADDITION TO PAYMENT, ARCHITECT'S WRITTEN AUTHORIZATION AND ENGINEER'S RELEASE AGREEMENT FORM MUST BE RECEIVED BEFORE ELECTRONIC DRAWING FILES WILL BE SENT. 16A 1 -11 OPERATION AND MAINTENANCE INSTRUCTIONS SUBMIT TO THE ARCHITECT, FOR REVIEW, COPIES EACH OF OPERATIONS AND MAINTENANCE INSTRUCTION MANUALS, APPROPRIATELY BOUND INTO MANUAL FORM INCLUDING APPROVED COPIES OF THE FOLLOWING, REVISED IF NECESSARY TO SHOW SYSTEM AND EQUIPMENT AS ACTUALLY INSTALLED. PROVIDE THE NUMBER OF SUBMITTALS REQUIRED BY DIVISION 1; HOWEVER, AT A MINIMUM, SUBMIT THREE (3) SETS, AND INCLUDE, AT A MINIMUM, THE FOLLOWING INFORMATION: 1. MANUFACTURERS' CATALOGS AND PRODUCT DATA SHEETS 2. WIRING DIAGRAMS 3. MAINTENANCE INSTRUCTIONS 4. OPERATING INSTRUCTIONS 5. PARTS LISTS 6. TEST REPORTS AS DEFINED IN NETA ATS FOR THE SYSTEMS AND EQUIPMENT PROVIDED OR FURNISHED OR INSTALLED UNDER THIS CONTRACT. 7. NAMES, ADDRESSES, TELEPHONE NUMBERS, AND E -MAIL ADDRESSES OF LOCAL CONTACTS FOR WARRANTEE SERVICES AND SPARE PARTS. SUBMIT MANUALS PRIOR TO REQUESTING THE FINAL PUNCH UST AND BEFORE ANY REQUESTS FOR SUBSTANTIAL COMPLETION. ALSO PROVIDE ADEQUATE VERBAL INSTRUCTIONS OF SYSTEM OPERATIONS TO OWNER'S REPRESENTATIVE AT THE COMPLETION OF, AND BEFORE FINAL ACCEPTANCE OF, THE WORK. 16A 1 -12 TRAINING AT A TIME MUTUALLY AGREED UPON BETWEEN THE OWNER AND CONTRACTOR, PROVIDE THE SERVICES OF A FACTORY TRAINED AND AUTHORIZED REPRESENTATIVE TO TRAIN OWNER'S DESIGNATED PERSONNEL ON THE OPERATION AND MAINTENANCE OF THE EQUIPMENT PROVIDED FOR THIS PROJECT. PROVIDE TRAINING TO INCLUDE BUT NOT BE LIMITED TO AN OVERVIEW OF THE SYSTEM AND /OR EQUIPMENT AS IT RELATES TO THE FACILITY AS A WHOLE; OPERATION AND MAINTENANCE PROCEDURES AND SCHEDULES RELATED TO STARTUP AND SHUTDOWN, TROUBLESHOOTING, SERVICING, PREVENTIVE MAINTENANCE AND APPROPRIATE OPERATOR INTERVENTION; AND REVIEW OF DATA INCLUDED IN THE OPERATION AND MAINTENANCE INSTRUCTIONS. SUBMIT A CERTIFICATION LETTER TO THE ARCHITECT STATING THAT THE OWNER'S DESIGNATED REPRESENTATIVE HAS BEEN TRAINED AS SPECIFIED HEREIN. LETTER SHALL INCLUDE DATE, TIME, ATTENDEES AND SUBJECT OF TRAINING. THE CONTRACTOR AND THE OWNER'S REPRESENTATIVE SHALL SIGN THE CERTIFICATION LETTER INDICATING AGREEMENT THAT THE TRAINING HAS BEEN PROVIDED. SCHEDULE TRAINING WITH OWNER WITH AT LEAST 7 DAYS' ADVANCE NOTICE. 16A 1 -13 WARRANTIES WARRANT EACH SYSTEM AND EACH ELEMENT THEREOF AGAINST ALL DEFECTS DUE TO FAULTY WORKMANSHIP, DESIGN OR MATERIAL FOR A PERIOD OF 12 MONTHS FROM DATE OF SUBSTANTIAL COMPLETION, UNLESS SPECIFIC ITEMS ARE NOTED TO CARRY A LONGER WARRANTY IN THE CONSTRUCTION DOCUMENTS OR MANUFACTURER'S STANDARD WARRANTY EXCEEDS 12 MONTHS. REMEDY ALL DEFECTS, OCCURRING WITHIN THE WARRANTY PERIOD(S), AS STATED IN THE GENERAL CONDITIONS AND DMSION 1. ALSO WARRANT THE FOLLOWING ADDITIONAL ITEMS: 1. ALL RACEWAYS ARE FREE FROM OBSTRUCTIONS, HOLES, CRUSHING, OR BREAKS OF ANY NATURE. 2. ALL RACEWAY SEALS ARE EFFECTIVE. 3. THE ENTIRE ELECTRICAL SYSTEM IS FREE FROM ALL SHORT CIRCUITS AND UNWANTED OPEN CIRCUITS AND GROUNDS. THE ABOVE WARRANTIES SHALL INCLUDE LABOR AND MATERIAL MAKE REPAIRS OR REPLACEMENTS WITHOUT ANY ADDITIONAL COSTS TO THE OWNER. PERFORM THE REMEDIAL WORK PROMPTLY, UPON WRITTEN NOTICE FROM THE ENGINEER OR OWNER. AT THE TIME OF SUBSTANTIAL COMPLETION, DELIVER TO THE OWNER ALL WARRANTIES, IN WRITING AND PROPERLY EXECUTED, INCLUDING TERM LIMITS FOR WARRANTIES EXTENDING BEYOND THE ONE YEAR PERIOD. EACH WARRANTY INSTRUMENT BEING ADDRESSED TO THE OWNER AND STATING THE COMMENCEMENT DATE AND TERM. 16A 1 -14 MISCELLANEOUS REMODELING WORK PROVIDE ALL DEMOLITION OF EXISTING ELECTRICAL SYSTEMS AND NEW ELECTRICAL SYSTEM MODIFICATIONS REQUIRED BECAUSE OF BUILDING REMODELING, AS NOTED ON THE DRAWINGS, OR NECESSARY FOR PROPER OPERATION AND NEW CONSTRUCTION. REMOVE ALL ABANDONED CABLES AND WIRING ABOVE ACCESSIBLE CEIUNGS AND VENTILATION SHAFTS. 16A 2 ELECTRICAL WORK 16A 2 -1 BUILDING OPERATION COMPLY WITH THE SCHEDULE OF OPERATIONS AS OUTLINED IN THE ARCHITECTURAL PORTIONS OF THIS SPECIFICATION. BUILDING SHALL BE IN CONTINUOUS OPERATION. ACCOMPLISH WORK THAT REQUIRES INTERRUPTION OF BUILDING OPERATION AT A TIME WHEN THE BUILDING IS NOT IN OPERATION, AND ONLY WITH WRITTEN APPROVAL OF BUILDING OWNER AND /OR TENANT. COORDINATE INTERRUPTION OF BUILDING OPERATION WITH THE OWNER AND /OR TENANT A MINIMUM OF 7 DAYS IN ADVANCE OF WORK. 16A 2-2 EXCAVATION AND BACKFILLING PERFORM EXCAVATION AND BACKFILL REQUIRED FOR INSTALLATION OF UNDERGROUND WORK UNDER THIS CONTRACT. TRENCHES SHALL BE OF SUFFICIENT WIDTH. CRIB OR BRACE TRENCHES TO PREVENT CAVE -IN OR SETTLEMENT. DO NOT EXCAVATE TRENCHES CLOSE TO COLUMNS AND WALLS OF NEW BUILDING WITHOUT PRIOR CONSULTATION WITH THE ENGINEER. USE PUMPING EQUIPMENT IF REQUIRED TO KEEP TRENCHES FREE OF WATER. BACKFILL TRENCHES IN MAXIMUM 6 -INCH LAYERS OF WELL TAMPED DRY EARTH IN A MANNER TO PREVENT FUTURE SLIILEMENT. EXCAVATION AS HEREIN SPECIFIED SHALL BE CLASSIFIED AS COMMON EXCAVATION. COMMON EXCAVATION SHALL COMPRISE THE SATISFACTORY REMOVAL AND DISPOSITION OF MATERIAL OF WHATEVER SUBSTANCES AND OF EVERY DESCRIPTION ENCOUNTERED, INCLUDING ROCK, IF ANY, WITHIN THE LIMITS OF THE WORK AS SPECIFIED AND SHOWN ON THE DRAWINGS. EXCAVATION SHALL BE PERFORMED TO THE UNES AND GRADES INDICATED ON THE DRAWINGS. DISPOSE OF EXCAVATED MATERIALS THAT ARE CONSIDERED UNSUITABLE FOR BACKFILL, AND SURPLUS OF EXCAVATED MATERIAL, WHICH IS NOT REQUIRED FOR BACKFILL, ALL TO THE SATISFACTION OF THE ENGINEER. 16A 2 -3 COINCIDENTAL DAMAGE REPAIR ALL STREETS, SIDEWALKS, DRIVES, PAVING, WALLS, FINISHES, AND OTHER FACILITIES DAMAGED IN THE COURSE OF THIS WORK. REPAIR MATERIALS SHALL MATCH EXISTING CONSTRUCTION. REPAIR MATERIALS SHALL GENERALLY MATCH EXISTING CONSTRUCTION. ALL BACKFILLING AND REPAIRING SHALL MEET ALL REQUIREMENTS OF THE OWNER, CITY AND OTHERS HAVING JURISDICTION. REPAIR WORK SHALL BE THOROUGHLY FIRST CLASS. CONFORM TO ALL REQUIREMENTS OF DMSION 2 OF THESE SPECIFICATIONS. 16A 2 -4 CUTTING AND PATCHING FOLLOWING THE REQUIREMENTS IN DIVISION 1, CUT WALLS, FLOORS, CEILINGS, AND OTHER PORTIONS OF THE FACILITY AS REQUIRED TO PERFORM WORK UNDER THIS DMSION. OBTAIN PERMISSION OF THE ENGINEER, OWNER, OR BOTH, BEFORE DOING ANY CUTTING. CUT ALL HOLES AS SMALL AS POSSIBLE. PATCH WALLS, FLOORS, AND OTHER PORTIONS OF THE FACILTY AS REQUIRED BY WORK UNDER THIS DIVISION. ALL PATCHING SHALL BE THOROUGHLY FIRST CLASS AND SHALL MATCH THE ORIGINAL MATERIAL AND CONSTRUCTION, INCLUDING FIRE RATINGS IF APPLICABLE. 16A 2-5 ROUGH -IN COORDINATE WITHOUT DELAY ALL ROUGHING -IN WITH OTHER DMSIONS. CONCEAL ALL RACEWAYS EXCEPT IN UNFINISHED AREAS AND WHERE OTHERWISE INDICATED ON THE DRAWINGS. 16A 2 -6 SUPPORT SYSTEMS STEEL SLOTTED SUPPORT SYSTEMS (SLOTTED CHANNEL): COMPLY WITH MFMA -3, FACTORY - FABRICATED COMPONENTS FOR FIELD ASSEMBLY; 12- GAUGE, 1 -5/8 -INCH BY 1 -5/8 -INCH; COOPER B -LINE, ERICO INTERNATIONAL CORPORATION, HILTI, INC., POWER- STRUT, THOMAS & BETTS CORPORATION, UNISTRUT. FINISHES: 1. METALUC COATINGS: HOT -DIP GALVANIZED AFTER FABRICATION AND APPLIED ACCORDING TO MFMA -3. 2. FIELD FABRICATION: 1. WHERE FIELD CUTTING OF STANDARD LENGTHS OF CHANNEL ARE REQUIRED, MAKE CUTS STRAIGHT AND PERPENDICULAR TO MANUFACTURED SURFACES. 2. FOR FIELD -CUT OR DAMAGED SURFACES OF COATED CHANNELS, DRESS CUT ENDS, DAMAGED SURFACES, OR BOTH, WITH AN ABRASIVE MATERIAL (E.G., FILE, GRINDING STONE, OR SIMILAR) AND CLEANSER TO REMOVE OILS, RUST, SHARP EDGES AND SHARDS. 3. FOR CHANNEL WITH A FACTORY - APPLIED COATING. RE- FINISH CUT EDGES WITH A COATING COMPATIBLE WITH THE FACTORY FINISH AND AS RECOMMENDED BY THE MANUFACTURER (E.G., MANUFACTURER'S TOUCH -UP PAINT OR ZINC -RICH COLD- GALVANIZING COMPOUND, AS APPUCABLE). 16A 2 -7 PENETRATIONS COORDINATE SLEEVE SELECTION AND APPUCATION WITH SELECTION AND APPLICATION OF FIRE- STOPPING SPECIFIED IN DIVISION 7 SECTION "THROUGH - PENETRATION FIRESTOP SYSTEMS." ROOFS: COORDINATE ALL ROOF PENETRATIONS WITH ENGINEER, OWNER, AND AS APPLICABLE, THE ROOFING CONTRACTOR PROVIDING A ROOF WARRANTY. 2. KEEP ALL RACEWAY PENETRATIONS WITHIN MECHANICAL EQUIPMENT CURBS WHEREVER POSSIBLE. COORDINATE WITH DIVISION 15 WORK. 3. FLASH AND COUNTERFLASH ALL OPENINGS THROUGH ROOF, AND /OR PROVIDE PRE- FABRICATED MOLDED SEALS COMPATIBLE WITH THE ROOF CONSTRUCTION INSTALLED, OR AS REQUIRED BY THE ENGINEER, OWNER, OR ROOFING CONTRACTOR. ALL ROOF PENETRATIONS SHALL BE LEAKTIGHT AT THE TERMINATION OF THE WORK AND SHALL NOT VOID ANY NEW OR EXISTING ROOF WARRANTIES. WALLS AND FLOORS; 1. A. STEEL PIPE SLEEVES: ASTM A 53/A 53M, TYPE E, GRADE B, SCHEDULE 40. GALVANIZED STEEL, PLAIN ENDS AND DRIP RINGS. SLEEVES FOR RACEWAYS AND CABLES B. CAST -IRON PIPE SLEEVES: CAST OR FABRICATED "WALL PIPE," EQUIVALENT TO DUCTILE - IRON PRESSURE PIPE, WITH PLAIN ENDS AND INTEGRAL WATERSTOP, UNLESS OTHERWISE INDICATED. 2. SLEEVES FOR RECTANGULAR OPENINGS: GALVANIZED SHEET STEEL WITH MINIMUM 0.052 - INCH THICKNESS AS INDICATED AND OF LENGTH TO SUIT APPLICATION. 16B 2 -8 FIRF- STOPPING THROUGH PENETRATIONS FIRE- RESISTANT THROUGH PENETRATION SEALANTS: TWO -PART, FOAMED -IN- PLACE, SIUCONE SEALANT FORMULATED FOR USE IN THROUGH- PENETRATION FIRE - STOPPING AROUND CABLES, RACEWAYS, AND CABLE TRAY PENETRATIONS THROUGH FIRE -RATED WALLS AND FLOORS. SEALANTS AND ACCESSORIES SHALL HAVE FIRE- RESISTANCE RATINGS INDICATED, AS ESTABLISHED BY TESTING IDENTICAL ASSEMBLIES IN ACCORDANCE WFTH ASTM E 814, BY UNDERWRITERS' LABORATORIES, INC„ OR OTHER NRTL ACCEPTABLE TO AHJ. 1. ACCEPTABLE MANUFACTURERS: A. HILTI, INC. B. 3M CORP. C. RECTORSEAL. D. SPECIFY TECHNOLOGY INC. E. UNITED STATES GYPSUM COMPANY. 16A 2 -9 ACCESS DOORS PROVIDE ACCESS DOORS IN CEILINGS AND WALLS, WHERE INDICATED OR REQUIRED FOR ACCESS OR MAINTENANCE TO CONCEALED EQUIPMENT INSTALLED UNDER THIS SECTION. PROVIDE CONCEALED HINGES, SCREWDRIVER -TYPE LOCK, AND ANCHOR STRAPS. MANUFACTURED BY MILCOR, ZURN, TITUS, OR EQUAL OBTAIN ARCHITECT'S APPROVAL OF TYPE, SIZE, LOCATION AND COLOR BEFORE ORDERING. 16A 2 -10 EQUIPMENT FURNISHED BY OTHERS PROVIDE NECESSARY EQUIPMENT AND ACCESSORIES THAT ARE NOT PROVIDED BY THE EQUIPMENT SUPPLIER OR OWNER TO COMPLETE INSTALLATION OF EQUIPMENT FURNISHED BY OTHERS, IN LOCATIONS AS INDICATED ON THE DRAWINGS, SPECIFIED HEREIN, OR BOTH. EQUIPMENT AND ACCESSORIES NOT PROVIDED BY THE EQUIPMENT SUPPLIER MAY INCLUDE SUCH ITEMS AS FLEXIBLE CORDS AND PLUGS, AS REQUIRED FOR PROPER OPERATION OF THE COMPLETE SYSTEM, IN ACCORDANCE WITH THE MANUFACTURERS' INSTRUCTIONS. BE RESPONSIBLE FOR CORRECT ROUGH -IN DIMENSIONS, AND VERIFY THEM WITH ENGINEER. OWNER'S REPRESENTATIVE, EQUIPMENT SUPPLIER, OR ALL THREE, PRIOR TO ROUGH -IN AND SERVICE INSTALLATIONS. 16A 2 -11 CLEANING IN ADDITION TO THE REQUIREMENTS OF DIVISION 1, REMOVE FROM THE PREMISES DIRT AND REFUSE RESULTING FROM THE PERFORMANCE OF THE ELECTRICAL WORK, AS REQUIRED, TO PREVENT ACCUMULATION. COOPERATE IN MAINTAINING REASONABLY CLEAN PREMISES AT ALL TIMES. IMMEDIATELY PRIOR TO FINAL INSPECTION, MAKE A FINAL CLEANUP OF DIRT AND REFUSE RESULTING FROM THE WORK. CLEAN ALL MATERIAL AND EQUIPMENT INSTALLED UNDER THIS DIVISION. REMOVE DIRT, DUST, PLASTER, STAINS AND FOREIGN MATTER FROM ALL SURFACES. TOUCH UP AND RESTORE ALT. DAMAGED FINISHES TO THEIR ORIGINAL CONDITION. 16A 2 -12 ADJUSTING, ALIGNING AND TESTING ADJUST, ALIGN, AND TEST ALL ELECTRICAL EQUIPMENT ON THIS PROJECT PROVIDED UNDER THIS DIVISION AND ALL ELECTRICAL EQUIPMENT FURNISHED BY OTHERS FOR INSTALLATION OR WIRING UNDER THIS DIVISION, FOR PROPER OPERATION. TEST ALL SYSTEMS AND EQUIPMENT ACCORDING TO THE REQUIREMENTS IN NETA ATS (LATEST EDITION) AND ALL ADDITIONAL REQUIREMENTS SPECIFIED IN FOLLOWING SECTIONS. MAINTAIN THE FOLLOWING ON THE PROJECT PREMISES AT ALL TIMES: A TRUE RMS READING VOLTMETER, A TRUE RMS READING AMMETER, AND A MEGOHMMETER INSULATION RESISTANCE TESTER. PROVIDE TEST DATA READINGS AS REQUESTED OR AS REQUIRED BY THE ENGINEER. 16A 2 -13 EQUIPMENT IDENTIFICATION PROVIDE EQUIPMENT IDENTIFICATION NAMEPLATES: 1. ON ALL PANELBOARDS, SWITCHES, STARTERS, DIMMERS, SWITCHES IN DISTRIBUTION PANELBOARDS AND SWITCHBOARDS. NAMEPLATES: 1. ENGRAVED, CONTRASTING COLOR, THREE - LAYER, LAMINATED PLASTIC INDICATING THE NAME OF THE EQUIPMENT, LOAD, OR CIRCUIT AS DESIGNATED ON THE DRAWINGS AND IN THE SPECIFICATIONS: 2. SELF - ADHERING, WITH A PERMANENT, WEATHERPROOF ADHESIVE 3. ATTACHMENT METHOD SHALL BE ACCEPTABLE TO THE MANUFACTURERS OF THE EQUIPMENT TO WHICH THE NAMEPLATES ARE BEING APPLIED. 4. COLOR: BLACK BACKGROUND WITH WHITE LETTERS. LETTER HEIGHT: 1/4-INCH MINIMUM. 16A 2 -14 SYSTEM START UP PRIOR TO STARTING UP THE ELECTRICAL SYSTEMS: 1. CHECK ALL COMPONENTS AND DEVICES. 2. LUBRICATE ITEMS ACCORDINGLY. 3. TIGHTEN SCREWS AND BOLTS FOR CONNECTORS AND TERMINALS ACCORDING TO MANUFACTURER'S PUBLISHED TORQUE - TIGHTENING VALUES. IF MANUFACTURER'S TORQUE VALUES ARE NOT INDICATED, USE THOSE SPECIFIED IN UL 486A [AND UL 486B]. 4. ADJUST TAPS ON EACH TRANSFORMER FOR RATED SECONDARY VOLTAGE. 5. CHECK AND RECORD BUILDING'S SERVICE ENTRANCE VOLTAGE, GROUNDING CONDITIONS. GROUNDING RESISTANCE, AND PROPER PHASING. 6. BALANCE ALL SINGLE -PHASE LOADS AT EACH PANELBOARD, REDISTRIBUTING BRANCH CIRCUIT CONNECTIONS UNTIL BALANCE IS ACHIEVED. DO NOT TYPE UP FINAL PANELBOARD DIRECTORIES UNTIL ALL RE- BALANCING AND REDISTRIBUTION OF CIRCUITS ARE COMPLETE. 7. REPLACE ALL BURNED -OUT LAMPS AND LAMPS USED FOR TEMPORARY CONSTRUCTION LIGHTING IN PERMANENT UGHT FIXTURES. 8. AFTER ALL SYSTEMS HAVE BEEN INSPECTED AND ADJUSTED, CONFIRM ALL OPERATING FEATURES REQUIRED BY THE DRAWINGS AND SPECIFICATIONS AND MAKE FINAL ADJUSTMENTS AS NECESSARY. 16A 3 EXISTING EQUIPMENT REUSE AND REMOVAL REMOVE ALL EXISTING WIRING. UGHT FIXTURES. EXPOSED CONDUITS AND OTHER ELECTRICAL INSTALLATIONS NOT REUSED PRIOR TO SUBSTANTIAL COMPLETION OF THE WORK. EXISTING RACEWAYS MAY BE REUSED IF THEIR POINTS OF TERMINATIONS ARE SUITABLE; IF THEY ARE CLEAN INSIDE WITH NO EVIDENCE OF RUST OR BURRS; IF FREE FROM CRACKS, FLATTENED SECTIONS OR SHARP BENDS; AND, IF SUITABLY LOCATED TO AVOID CONFLICTS WITH OTHER TRADES OR INSTALLATIONS. CAREFULLY "FISH" ALL EXISTING CONDUITS REUSED UNDER THIS CONTRACT TO REMOVE ALL DEBRIS AND OBSTRUCTIONS, AND SWAB UNTIL ALL MOISTURE IS REMOVED. CUT. PATCH, AND REPAIR WHERE REQUIRED FOR NEW ELECTRICAL INSTALLATIONS. AND PATCH AND REPAIR ALL SURFACE DAMAGE RESULTING FROM THIS WORK. CUT FLUSH WITH THE FLOOR AND PLUG AT BOTH ENDS, RACEWAYS STUBBED ABOVE THE FLOOR AND NOT USED AT SUBSTANTIAL COMPLETION OF THE WORK. RELOCATE ALL EXISTING ELECTRICAL SYSTEMS REQUIRED TO BE IN OPERATION AT SUBSTANTIAL COMPLETION OF THE CONTRACT, IF REQUIRED, AS A RESULT OF WORK INCLUDED UNDER THIS CONTRACT. EVEN IF NOT SPECIFICALLY INDICATED IN THE DRAWINGS OR SPECIFICATIONS. SECTION 16B BASIC ELECTRICAL MATERIALS AND METHODS 1613 1 METHODS 16B 1 -1 RACEWAYS METALLIC CONDUIT: 1. ELECTRICAL METALLIC TUBING AND FITTINGS (EMT): ANSI C80.3, UL 797. 2. FLEXIBLE METAL CONDUIT (FMC): ZINC - COATED STEEL OR ALUMINUM, UL 1. 3. INTERMEDIATE METAL CONDUIT (IMC): HOT-DIP GALVANIZED RIGID STEEL CONDUIT: ANSI C80.6, UL 1242. 4. UQUIDTIGHT FLEXIBLE METAL CONDUIT (LFMC): FLEXIBLE STEEL CONDUIT WITH PVC JACKET: UL 360 5. RIGID METAL CONDUIT (RMC): HOT -DIP GALVANIZED RIGID STEEL CONDUIT (GRS): ANSI C80.1, UL 6. 6. RIGID ALUMINUM CONDUIT (RAC): ANSI C80.5, UL 6A. 7. PLASTIC - COATED IMC, RMC, AND FITTINGS: NEMA RN 1, UL LISTED. 8. IMC AND RMC FITTINGS: NEMA FB 1; COMPATIBLE WITH CONDUIT TYPE AND MATERIAL, UL LISTED NON- METALLIC CONDUIT AND TUBING: 1. RIGID NONMETALLIC CONDUIT (RNC): SCHEDULE 40 PVC, 90 DEG C RATED, NEMA TC -2, UL 651; FITTINGS: NEMA TC 3, TC 6; UL 514, COMPATIBLE WITH CONDUIT TYPE AND MATERIAL, UL LISTED. 16B 1 -2 RACEWAY INSTALLATION INSTALL ALL CIRCULAR RACEWAYS CONCEALED ABOVE SUSPENDED CEILINGS OR CONCEALED IN WALLS OR FLOORS WHEREVER POSSIBLE EXCEPT WHERE OTHERWISE INDICATED. PROVIDE GRS FOR ALL CONDUITS RUN UNDERGROUND, EXPOSED TO WEATHER, OR EXPOSED TO OTHER HAZARDOUS CONDITIONS. PROVIDE GRS INSTALLED BELOW GRADE WITH A CORROSION RESISTANT BONDED - PLASTIC OR APPROVED MASTIC COATING. THIS SHALL INCLUDE THE 90- DEGREE ELBOW BELOW GRADE AND THE ENTIRE VERTICAL TRANSITION TO ABOVE GRADE. ALL OTHER RACEWAY MAY BE EMT WHERE APPROVED BY LOCAL CODE. USE COMPRESSION TYPE FITTINGS FOR EMT, WITH ALL FITTINGS UL LISTED FOR THE ENVIRONMENT IN WHICH THEY ARE USED. AT CONTRACTOR'S OPTION, PVC CONDUIT MAY BE USED UNDERGROUND WHERE PERMITTED BY LOCAL CODE AND WHERE NOT SPECIFICALLY RESTRICTED BY THESE DOCUMENTS. WHEN USED, PROVIDE COATED GRS, AS SPECIFIED ABOVE, FOR ALL BENDS GREATER THAN 30 DEGREES, INCLUDING THE 90- DEGREE ELBOWS BELOW GRADE AND THE ENTIRE VERTICAL RISERS FOR TRANSITIONS FROM BELOW TO ABOVE GRADE OR ABOVE -SLAB. USE FMC FOR FINAL CONNECTION TO EACH MOTOR AND TRANSFORMER, AND TO ANY DEVICE THAT WOULD OTHERWISE TRANSMIT MOTION, VIBRATION, OR NOISE. USE LFMC WHERE EXPOSED TO UQUIDS, VAPORS OR SUNLIGHT, AND TO CONNECT TO KITCHEN AND FOOD SERVICE EQUIPMENT. PROVIDE ALL FMC AND LFMC WITH AN INSULATED BONDING CONDUCTOR. USE ONLY METAL RACEWAYS FOR ALL POWER WIRING FROM THE OUTPUT OF VARIABLE FREQUENCY DRIVES TO THEIR RESPECTIVE MOTORS. INSTALL RACEWAYS PARALLEL AND PERPENDICULAR TO BUILDING LINES. INSTALL RACEWAYS TO REQUIREMENTS OF STRUCTURE AND TO REQUIREMENTS OF ALL OTHER WORK ON THE PROJECT. INSTALL RACEWAY TO CLEAR ALL OPENINGS, DEPRESSIONS. PIPES, DUCTS, REINFORCING STEEL, AND OTHER IMMOVABLE OBSTACLES. INSTALL RACEWAYS SET IN FORMS FOR CONCRETE STRUCTURE IN SUCH A MANNER THAT INSTALLATION WILL NOT AFFECT THE STRENGTH OF THE STRUCTURE. EXCEPT WHERE APPROVED IN WRITING BY THE ENGINEER, INSTALL NO RACEWAY IN A SLAB -ON- GRADE. LOCATE RACEWAY IN GRANULAR FILL BELOW SLABS -ON- GRADE. INSTALL RACEWAYS CONTINUOUS BETWEEN CONNECTIONS TO OUTLETS, BOXES AND CABINETS WITH A MINIMUM POSSIBLE NUMBER OF BENDS AND NOT MORE THAN THE EQUIVALENT OF FOUR 90- DEGREE BENDS BETWEEN CONNECTIONS. USE MANUFACTURED ELBOWS FOR ALL 45- AND 90- DEGREE BENDS, UNLESS APPROVED BY THE ENGINEER IN ADVANCE. MAKE OTHER BENDS SMOOTH AND EVEN AND WITHOUT FLATTENING RACEWAY OR FLAKING GALVANIZING OR ENAMEL RADII OF BENDS SHALL BE AS LONG AS POSSIBLE AND NEVER SHORTER THAN THE CORRESPONDING TRADE ELBOW. USE LONG RADIUS ELBOWS WHERE NECESSARY, INDICATED, OR BOTH. SECURELY FASTEN RACEWAYS IN PLACE WITH APPROVED STRAPS, HANGERS AND STEEL SUPPORTS AS REQUIRED. ATTACH RACEWAY SUPPORTS TO THE BUILDING STRUCTURE. HANG SINGLE RACEWAYS FOR FEEDERS WITH MALLEABLE SPLIT RING HANGERS WITH ROD AND TURNBUCKLE SUSPENSION FROM INSERTS SPACED NOT OVER 10 FEET APART IN CONSTRUCTION ABOVE. CLAMP GROUPS OF HORIZONTAL FEEDER RACEWAYS TO STEEL CHANNELS THAT ARE SUSPENDED FROM INSERTS SPACED NOT OVER 10 FEET APART IN CONSTRUCTION ABOVE. SECURELY CLAMP VERTICAL FEEDER RACEWAYS TO STRUCTURAL STEEL MEMBERS ATTACHED TO STRUCTURE. INSTALL CABLE CLAMPS FOR SUPPORT OF VERTICAL FEEDERS WHERE REQUIRED. ADD RACEWAY SUPPORTS WITHIN 12 INCHES OF ALL BENDS, ON BOTH SIDES OF THE BENDS. DO NOT SUPPORT RACEWAYS FROM SUSPENDED CEIUNG COMPONENTS. REAM RACEWAY ENDS, THOROUGHLY CLEAN RACEWAYS BEFORE INSTALLATION, AND KEEP CLEAN AFTER INSTALLATION. PLUG OR COVER OPENINGS AND BOXES AS REQUIRED TO KEEP RACEWAYS CLEAN DURING CONSTRUCTION AND FISH ALL RACEWAYS CLEAR OF OBSTRUCTIONS BEFORE PULLING CONDUCTORS WIRES. PROVIDE RACEWAYS OF AMPLE SIZE FOR PUWNG OF WIRE AND NOT SMALLER THAN CODE REQUIREMENTS AND NOT LESS THAN 1/2 -INCH IN SIZE, UNLESS INDICATED OTHERWISE ON DRAWINGS. PROTECT ALL RACEWAY INSTALLATIONS AGAINST DAMAGE DURING CONSTRUCTION. REPAIR ALL RACEWAYS DAMAGED OR MOVED OUT OF UNE AFTER ROUGHING -IN TO MEET ENGINEER'S APPROVAL WITHOUT ADDITIONAL COST TO THE OWNER. AUGN AND INSTALL TRUE AND PLUMB ALL RACEWAY TERMINATIONS AT PANELBOARDS, SWITCHBOARDS, MOTOR CONTROL EQUIPMENT AND JUNCTION BOXES. INSTALL APPROVED EXPANSION /DEFLECTION FITTINGS WHERE RACEWAYS PASS THROUGH (IF EMBEDDED) OR ACROSS (IF EXPOSED) EXPANSION JOINTS. INSTALL A PULL WIRE IN EACH EMPTY RACEWAY THAT IS LEFT FOR INSTALLATION OF CONDUCTORS OR CABLES UNDER OTHER DIVISIONS OR CONTRACTS. USE POLYPROPYLENE OR MONOFILAMENT PLASTIC LINE WITH NOT LESS THAN 200 -LB TENSILE STRENGTH. LEAVE AT LEAST 24 INCHES OF SLACK AT EACH END OF PULL WIRE. MAKE ALL JOINTS AND CONNECTIONS IN A MANNER THAT WILL. ENSURE MECHANICAL STRENGTH AND ELECTRICAL CONTINUITY. EFFECTIVELY SEAL RACEWAYS, BY INSTALLING A CONDUIT I-11 IING AT THE BOUNDARY OF THE TWO SPACES, AND FILLING IT WITH AN APPROVED PLIABLE MATERIAL. AFTER CONDUCTORS OR CABLES HAVE BEEN INSTALLED AND TESTED, WHEN EVER: 1. RACEWAYS PASS FROM NON- COOLED TO COOLED SPACES. 2. RACEWAYS TRANSITION FROM OUTSIDE A FACILITY OR ENCLOSURE TO INSIDE, WHETHER BURIED OR EXPOSED. R `E :V D CT 15nil r Le el4tl 1 CEN I (=f( PROJ. DRWN. DATE 2007 -0174 EC 9 -25 -07 E6 26 OF 27 SECTION 16A GENERAL ELECTRICAL REQUIREMENTS: 16A 1 GENERAL INSTRUCTIONS 16A 1 -1 GENERAL REQUIREMENTS ALL REQUIREMENTS UNDER DMSION 1 AND THE GENERAL AND SUPPLEMENTARY CONDITIONS OF THESE SPECIFICATIONS APPLY TO THIS SECTION AND DIVISION, WHERE THE REQUIREMENTS OF THIS SECTION AND DIVISION EXCEED THOSE OF DMSION 1, THIS SECTION AND DIVISION TAKE PRECEDENCE. BECOME THOROUGHLY FAMILIAR WITH ALL THEIR CONTENTS AS TO REQUIREMENTS THAT AFFECT THIS DIVISION, SECTION OR BOTH. WORK REQUIRED UNDER THIS DIVISION INCLUDES ALL MATERIAL EQUIPMENT, APPLIANCES, AND LABOR REQUIRED TO COMPLETE THE ENTIRE ELECTRICAL SYSTEM AS REQUIRED BY THE DRAWINGS AND SPECIFICATIONS, OR REASONABLY INFERRED TO BE NECESSARY TO FACILITATE EACH SYSTEM'S FUNCTIONING AS IMPLIED BY THE DESIGN AND THE EQUIPMENT SPECIFIED. THE SPECIFICATIONS AND DRAWINGS FOR THE PROJECT ARE COMPLEMENTARY, AND PORTIONS OF THE WORK DESCRIBED IN ONE, SHALL BE PROVIDED AS IF DESCRIBED IN BOTH. IN THE EVENT OF DISCREPANCIES, NOTIFY THE ENGINEER AND REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH THE WORK INVOLVED. DRAWINGS ARE GRAPHIC REPRESENTATIONS OF THE WORK UPON WHICH THE CONTRACT IS BASED. THEY SHOW THE MATERIALS AND THEIR RELATIONSHIP TO ONE ANOTHER, INCLUDING SIZES, SHAPES, LOCATIONS, AND CONNECTIONS. THEY ALSO CONVEY THE SCOPE OF WORK, INDICATING THE INTENDED GENERAL ARRANGEMENT OF THE EQUIPMENT, FIXTURES, OUTLETS AND CIRCUITS WITHOUT SHOWING ALL OF THE EXACT DETAILS AS TO ELEVATIONS, OFFSETS, CONTROL LINES, AND OTHER INSTALLATION REQUIREMENTS. USE THE DRAWINGS AS A GUIDE WHEN LAYING OUT THE WORK AND TO VERIFY THAT MATERIALS AND EQUIPMENT WILL FIT INTO THE DESIGNATED SPACES, AND WHICH, WHEN INSTALLED PER MANUFACTURERS' REQUIREMENTS, WILL ENSURE A COMPLETE, COORDINATED, SATISFACTORY AND PROPERLY OPERATING SYSTEM. DRAWINGS ARE SCHEMATIC IN NATURE, SHOW THE VARIOUS COMPONENTS OF THE SYSTEMS APPROXIMATELY TO SCALE AND ATTEMPT TO INDICATE HOW THEY SHALL BE INTEGRATED WITH OTHER PARTS OF THE WORK. FIGURED DIMENSIONS TAKE PRECEDENCE TO SCALED DIMENSIONS. DETERMINE EXACT LOCATIONS BY JOB MEASUREMENTS, BY CHECKING THE REQUIREMENTS OF OTHER TRADES, AND BY REVIEWING ALL CONTRACT DOCUMENTS. CORRECT ERRORS THAT COULD HAVE BEEN AVOIDED BY PROPER CHECKING AND INSPECTION, AT NO ADDITIONAL COST TO THE OWNER. SPECIFICATIONS DEFINE THE QUALITATIVE REQUIREMENTS FOR PRODUCTS. MATERIALS, AND WORKMANSHIP UPON WHICH THE CONTRACT IS BASED. 16A 1 -2 DEFINITIONS WHENEVER USED IN THESE SPECIFICATIONS OR DRAWINGS, THE FOLLOWING TERMS SHALL HAVE THE INDICATED MEANINGS: 1. FURNISH: "TO SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBUNG, INSTALLING, AND SIMILAR OPERATIONS." 2. INSTALL ' PERFORM ALL OPERATIONS AT THE PROJECT SITE, INCLUDING, BUT NOT LIMITED TO, AND AS REQUIRED: UNLOADING, UNPACKING, ASSEMBUNG, ERECTING, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, TESTING, COMMISSIONING, STARTING UP AND SIMILAR OPERATIONS, COMPLETE, AND READY FOR THE INTENDED USE." 3. PROVIDE: "TO FURNISH AND INSTALL COMPLETE, AND READY FOR THE INTENDED USE." 4. FURNISHED BY OWNER (OR OWNER - FURNISHED) OR FURNISHED BY OTHERS: AN ITEM FURNISHED BY THE OWNER OR UNDER OTHER DMSIONS OR CONTRACTS, AND INSTALLED UNDER THE REQUIREMENTS OF THIS DIVISION, COMPLETE, AND READY FOR THE INTENDED USE, INCLUDING ALL ITEMS AND SERVICES INCIDENTAL TO THE WORK NECESSARY FOR PROPER INSTALLATION AND OPERATION. INCLUDE THE INSTALLATION UNDER THE WARRANTY REQUIRED BY THIS DIVISION. 5. ENGINEER: WHERE REFERENCED IN THIS DIVISION, "ENGINEER" IS THE ENGINEER OF RECORD AND THE DESIGN PROFESSIONAL FOR THE WORK UNDER THIS DIVISION, AND IS A CONSULTANT TO, AND AN AUTHORIZED REPRESENTATIVE OF, THE ARCHITECT, AS DEFINED IN THE GENERAL AND /OR SUPPLEMENTARY CONDITIONS. WHEN USED IN THIS DIVISION, IT MEANS INCREASED INVOLVEMENT BY, AND OBLIGATIONS TO, THE ENGINEER, IN ADDITION TO INVOLVEMENT BY, AND OBLIGATIONS TO, THE "ARCHITECT ". 6. AHJ: THE LOCAL CODE AND /OR INSPECTION AGENCY (AUTHORITY) HAVING JURISDICTION OVER THE WORK. 7. NRTL: NATIONALLY RECOGNIZED TESTING LABORATORY, AS DEFINED AND LISTED BY OSHA IN 29 CFR 1910.7 (E.G., UL, ETL, CSA), AND ACCEPTABLE TO THE AHJ OVER THIS PROJECT. 8. THE TERMS "APPROVED EQUAL ", "EQUIVALENT ", OR "EQUAL" ARE USED SYNONYMOUSLY AND SHALL MEAN "ACCEPTED BY OR ACCEPTABLE TO THE ENGINEER AS EQUIVALENT TO THE ITEM OR MANUFACTURER SPECIFIED ". THE TERM "APPROVED" SHALL MEAN LABELED, LISTED, CERTIFIED, OR ALL THREE, BY AN NRTL, AND ACCEPTABLE TO THE AHJ OVER THIS PROJECT. 16A 1 -3 PRE -BID SITE VISIT PERSONALLY INSPECT THE SITE OF THE PROPOSED WORK AND BECOME FULLY INFORMED OF CONDITIONS UNDER WHICH THE WORK 15 TO BE DONE. FAILURE TO DO 50 WILL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO REQUEST OR OBTAIN EXTRA COMPENSATION OVER AND ABOVE THE CONTRACT PRICE. 16A 1 -4 MATERIAL AND WORKMANSHIP PROVIDE ALL MATERIAL AND EQUIPMENT NEW AND IN FIRST CLASS CONDITION. PROVIDE MARKINGS OR A NAMEPLATE FOR ALL MATERIAL AND EQUIPMENT IDENTIFYING THE MANUFACTURER AND PROVIDING SUFFICIENT REFERENCE TO ESTABLISH QUALITY, SIZE AND CAPACITY. ALL WORKMANSHIP SHALL BE OF THE FINEST POSSIBLE BY EXPERIENCED MECHANICS OF THE PROPER TRADE. IN GENERAL, PROVIDE THE FOLLOWING QUALITY GRADE(S) FOR ALL MATERIALS AND EQUIPMENT LIGHT DUTY AND RESIDENTIAL TYPE EQUIPMENT WILL NOT BE ACCEPTABLE: 1. COMMERCIAL SPECIFICATION GRADE PROVIDE ALL HOISTS, SCAFFOLDS, STAGING, RUNWAYS, TOOLS, MACHINERY AND EQUIPMENT REQUIRED FOR THE PERFORMANCE OF THE ELECTRICAL WORK. STORE AND MAINTAIN MATERIAL AND EQUIPMENT IN CLEAN CONDITION, AND PROTECTED FROM WEATHER, MOISTURE, AND PHYSICAL DAMAGE. FURNISH ONLY MATERIAL AND EQUIPMENT THAT ARE LISTED, LABELED. CERTIFIED, OR ALL THREE, BY A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL), WHENEVER ANY USTING OR LABELING EXISTS FOR THE TYPES OF MATERIAL AND EQUIPMENT SPECIFIED. AT A MINIMUM, GENERAL WORK PRACTICES FOR ELECTRICAL CONSTRUCTION SHALL BE IN ACCORDANCE WITH NECA 1 (LATEST EDITION), "STANDARD PRACTICES FOR GOOD WORKMANSHIP IN ELECTRICAL CONSTRUCTION ". 16A 1 -5 MANUFACTURERS IN OTHER ARTICLES WHERE USTS OF MANUFACTURERS ARE INTRODUCED, SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE MANUFACTURERS SPECIFIED. WHERE A UST IS PROVIDED, MANUFACTURERS ARE LISTED ALPHABETICALLY AND NOT IN ACCORDANCE WITH ANY RANKING OR PREFERENCE. WHERE MANUFACTURERS ARE NOT LISTED, PROVIDE PRODUCTS SUBJECT TO COMPLIANCE WITH REQUIREMENTS FROM MANUFACTURERS THAT HAVE BEEN ACTIVELY INVOLVED IN MANUFACTURING THE SPECIFIED PRODUCT FOR NO LESS THAN 5 YEARS. 16A 1 -6 COORDINATION COORDINATE ALL WORK WITH OTHER DIVISIONS AND TRADES 50 THAT VARIOUS COMPONENTS OF THE ELECTRICAL SYSTEMS ARE INSTALLED AT THE PROPER TIME, FIT THE AVAILABLE SPACE, AND ALLOW PROPER SERVICE ACCESS TO ALL EQUIPMENT. REFER TO ALL DRAWINGS, INCLUDING, BUT NOT LIMITED TO, CIVIL, ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND PLUMBING, AND TO RELEVANT EQUIPMENT SUBMITTALS AND SHOP DRAWINGS TO DETERMINE THE EXTENT OF CLEAR SPACES. MAKE ALL OFFSETS REQUIRED TO CLEAR EQUIPMENT, BEAMS AND OTHER STRUCTURAL MEMBERS, AND TO FACILITATE CONCEALING RACEWAYS IN THE MANNER ANTICIPATED IN THE DESIGN. PROVIDE MATERIALS WITH TRIM THAT WILL FIT PROPERLY THE TYPES OF CEILING, WALL, OR FLOOR FINISHES ACTUALLY INSTALLED 16A 1-7 ORDINANCES CODES. AND STANDARDS COMPLY. AT A MINIMUM, WITH NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) STANDARDS, STATE AND LOCAL BUILDING CODES, AND ALL OTHER APPLICABLE CODES AND ORDINANCES FOR PERFORMANCE, WORKMANSHIP, EQUIPMENT, AND MATERIALS. ADDITIONALLY, COMPLY WITH RULES AND REGULATIONS OF PUBUC UTILITIES AND MUNICIPAL DEPARTMENTS AFFECTED BY CONNECTION OF SERVICES. WHERE CONFLICTS BETWEEN VARIOUS CODES, ORDINANCES, RULES, AND REGULATIONS DCIST, COMPLY WITH THE MOST STRINGENT. WHEREVER REQUIREMENTS OF THESE SPECIFICATIONS, DRAWINGS, OR BOTH, EXCEED THOSE OF THE ABOVE ITEMS, THE REQUIREMENTS OF THESE SPECIFICATIONS, DRAWINGS, OR BOTH, SHALL GOVERN. CODE COMPLIANCE, AT A MINIMUM, IS MANDATORY. CONSTRUE NOTHING IN THESE CONSTRUCTION DOCUMENTS AS PERMITTING WORK NOT IN COMPLIANCE, AT A MINIMUM, WITH THESE CODES. BRING ALL CONFLICTS OBSERVED BETWEEN CODES, ORDINANCES, RULES, REGULATIONS, REFERENCED STANDARDS, AND THESE DOCUMENTS TO THE ENGINEER'S ATTENTION FOR FINAL RESOLUTION. CONTRACTOR WILL BE HELD RESPONSIBLE FOR ANY VIOLATION OF THE LAW. PROVIDE AND MAINTAIN ALL NECESSARY SIGNAL LIGHTS AND GUARDS FOR THE SAFETY OF THE PUBLIC. OBTAIN AND PAY FOR ALL PERMITS FOR WORK IN THIS DMSION. 16A 1 -8 PROTECTION OF EQUIPMENT AND MATERIALS STORE AND PROTECT FROM DAMAGE EQUIPMENT AND MATERIALS DELIVERED TO JOB SITE, IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. FOR MATERIALS AND EQUIPMENT SUSCEPTIBLE TO CHANGING WEATHER CONDITIONS, DAMPNESS, OR TEMPERATURE VARIATIONS, STORE INSIDE IN CONDITION SPACES. FOR MATERIALS AND EQUIPMENT NOT SUSCEPTIBLE TO THESE CONDITIONS, COVER WITH WATERPROOF, TEAR - RESISTANT, HEAVY TARP OR POLYETHYLENE PLASTIC AS REQUIRED TO PROTECT FROM PLASTER, DIRT, PAINT, WATER, OR PHYSICAL DAMAGE. EQUIPMENT AND MATERIAL THAT HAS BEEN DAMAGED BY CONSTRUCTION ACTIVITIES WILL BE REJECTED, AND CONTRACTOR SHALL FURNISH NEW EQUIPMENT AND MATERIAL OF A LIKE KIND. PLUG OR CAP OPEN ENDS OF CONDUITS WHILE STORED AND INSTALLED DURING CONSTRUCTION WHEN NOT IN USE TO PREVENT THE ENTRANCE OF DEBRIS INTO THE SYSTEMS. 16A 1 -9 SUBSTITUTIONS INCLUDE IN THE BASE BID THE PRODUCTS SPECIFICALLY NAMED IN THESE SPECIFICATIONS OR ON THE DRAWINGS. SUBMIT, IN THE FORM OF ALTERNATES, WITH BID, PRODUCTS OF ANY OTHER MANUFACTURERS FOR SIMILAR USE, PROVIDED THE DIFFERENCES IN COST, IF ANY, ARE INCLUDED FOR EACH PROPOSED ALTERNATE. PRIOR TO THE BID DATE. SUBSTITUTIONS WILL NOT BE CONSIDERED UNLESS SUBMITTED TO THE ARCHITECT, FOR REVIEW, AT LEAST TEN CALENDAR DAYS PRIOR TO THE DATE FOR RECEIPT OF BIDS. INCLUDE THE NAME OF THE MATERIAL OR EQUIPMENT FOR WHICH IT I5 TO BE SUBSTITUTED AND A COMPLETE DESCRIPTION OF THE PROPOSED SUBSTITUTE INCLUDING CUTSHEETS, PHOTOMETRIC DATA, AND ALL OTHER INFORMATION NECESSARY FOR AN EVALUATION FOR EACH SUCH REQUEST. PROVIDE FACTORY GENERATED POINT -BY- POINT CALCULATIONS FOR ALL EXTERIOR LIGHT FIXTURES (PHOTOMETRIC FILES SUPPLIED 50 THE ENGINEER CAN GENERATE A POINT -BY -POINT DO NOT SUFFICE FOR THE POINT -BY- POINT CALCULATIONS). PROVIDE INTERIOR POINT -BY -POINT CALCULATIONS AT THE DISCRETION OF THE ENGINEER. SUBMIT A $100.00 REVIEW FEE TO THE ENGINEER WITH EACH SUCH POINT -BY -POINT CALCULATION FOR USE OF ELECTRONIC BASE FILES. AFTER THE BID DATE, PROPOSALS TO SUBSTITUTE UGHT FIXTURES FOR THOSE SHOWN ON THE DRAWINGS OR SPECIFIED HEREIN, WILL ONLY BE CONSIDERED AS A DEDUCT. SUBMIT PROPOSED SUBSTITUTIONS SEPARATELY, IN SUBMITTAL FORM, WITH A UST OF PROPOSED SUBSTITUTIONS TOGETHER WITH A DEDUCT PRICE FOR EACH SUBSTITUTION. THE ARCHITECT, ENGINEER, OR BOTH, WILL THEN REVIEW PROPOSED SUBSTITUTIONS. THE ENGINEER WILL HAVE THE FINAL AUTHORITY AS TO WHETHER THE LIGHT FIXTURE IS AN ACCEPTABLE REPLACEMENT TO THE SPECIFIED ITEM. THE PROPOSED SUBSTITUTION MAY ALSO BE REJECTED BY THE ARCHITECT FOR AESTHETIC REASONS IF FELT NECESSARY OR DESIRABLE. IN THE EVENT THE PROPOSED SUBSTITUTIONS HEREIN DESCRIBED ARE REJECTED, FURNISH THE SPECIFIED ITEM. 16A 1 -10 ELECTRONIC DRAWING FILES IN PREPARATION OF SHOP DRAWINGS, CONTRACTOR MAY, AS AN OPTION, OBTAIN ELECTRONIC DRAWING FILES IN AUTOCAD OR DXF FORMAT FROM THE ENGINEER FOR A SHIPPING AND HANDLING FEE OF $200 FOR A DRAWING SET UP TO 12 SHEETS AND $15 PER SHEET FOR EACH ADDITIONAL SHEET. CONTACT THE ARCHITECT FOR WRITTEN AUTHORIZATION; AND. CONTACT THE ENGINEER TO OBTAIN THE NECESSARY RELEASE AGREEMENT FORM AND TO INDICATE THE DESIRED SHIPPING METHOD AND DRAWING FORMAT. IF A 100 MB ZIP DISK OR CD -ROM IS DESIRED, ADD THE APPROPRIATE CHARGE INDICATED. IN ADDITION TO PAYMENT, ARCHITECT'S WRITTEN AUTHORIZATION AND ENGINEER'S RELEASE AGREEMENT FORM MUST BE RECEIVED BEFORE ELECTRONIC DRAWING FILES WILL BE SENT. 16A 1 -11 OPERATION AND MAINTENANCE INSTRUCTIONS SUBMIT TO THE ARCHITECT, FOR REVIEW, COPIES EACH OF OPERATIONS AND MAINTENANCE INSTRUCTION MANUALS, APPROPRIATELY BOUND INTO MANUAL FORM INCLUDING APPROVED COPIES OF THE FOLLOWING, REVISED IF NECESSARY TO SHOW SYSTEM AND EQUIPMENT AS ACTUALLY INSTALLED. PROVIDE THE NUMBER OF SUBMITTALS REQUIRED BY DIVISION 1; HOWEVER, AT A MINIMUM, SUBMIT THREE (3) SETS, AND INCLUDE, AT A MINIMUM, THE FOLLOWING INFORMATION: 1. MANUFACTURERS' CATALOGS AND PRODUCT DATA SHEETS 2. WIRING DIAGRAMS 3. MAINTENANCE INSTRUCTIONS 4. OPERATING INSTRUCTIONS 5. PARTS LISTS 6. TEST REPORTS AS DEFINED IN NETA ATS FOR THE SYSTEMS AND EQUIPMENT PROVIDED OR FURNISHED OR INSTALLED UNDER THIS CONTRACT. 7. NAMES, ADDRESSES, TELEPHONE NUMBERS, AND E -MAIL ADDRESSES OF LOCAL CONTACTS FOR WARRANTEE SERVICES AND SPARE PARTS. SUBMIT MANUALS PRIOR TO REQUESTING THE FINAL PUNCH UST AND BEFORE ANY REQUESTS FOR SUBSTANTIAL COMPLETION. ALSO PROVIDE ADEQUATE VERBAL INSTRUCTIONS OF SYSTEM OPERATIONS TO OWNER'S REPRESENTATIVE AT THE COMPLETION OF, AND BEFORE FINAL ACCEPTANCE OF, THE WORK. 16A 1 -12 TRAINING AT A TIME MUTUALLY AGREED UPON BETWEEN THE OWNER AND CONTRACTOR, PROVIDE THE SERVICES OF A FACTORY TRAINED AND AUTHORIZED REPRESENTATIVE TO TRAIN OWNER'S DESIGNATED PERSONNEL ON THE OPERATION AND MAINTENANCE OF THE EQUIPMENT PROVIDED FOR THIS PROJECT. PROVIDE TRAINING TO INCLUDE BUT NOT BE LIMITED TO AN OVERVIEW OF THE SYSTEM AND /OR EQUIPMENT AS IT RELATES TO THE FACILITY AS A WHOLE; OPERATION AND MAINTENANCE PROCEDURES AND SCHEDULES RELATED TO STARTUP AND SHUTDOWN, TROUBLESHOOTING, SERVICING, PREVENTIVE MAINTENANCE AND APPROPRIATE OPERATOR INTERVENTION; AND REVIEW OF DATA INCLUDED IN THE OPERATION AND MAINTENANCE INSTRUCTIONS. SUBMIT A CERTIFICATION LETTER TO THE ARCHITECT STATING THAT THE OWNER'S DESIGNATED REPRESENTATIVE HAS BEEN TRAINED AS SPECIFIED HEREIN. LETTER SHALL INCLUDE DATE, TIME, ATTENDEES AND SUBJECT OF TRAINING. THE CONTRACTOR AND THE OWNER'S REPRESENTATIVE SHALL SIGN THE CERTIFICATION LETTER INDICATING AGREEMENT THAT THE TRAINING HAS BEEN PROVIDED. SCHEDULE TRAINING WITH OWNER WITH AT LEAST 7 DAYS' ADVANCE NOTICE. 16A 1 -13 WARRANTIES WARRANT EACH SYSTEM AND EACH ELEMENT THEREOF AGAINST ALL DEFECTS DUE TO FAULTY WORKMANSHIP, DESIGN OR MATERIAL FOR A PERIOD OF 12 MONTHS FROM DATE OF SUBSTANTIAL COMPLETION, UNLESS SPECIFIC ITEMS ARE NOTED TO CARRY A LONGER WARRANTY IN THE CONSTRUCTION DOCUMENTS OR MANUFACTURER'S STANDARD WARRANTY EXCEEDS 12 MONTHS. REMEDY ALL DEFECTS, OCCURRING WITHIN THE WARRANTY PERIOD(S), AS STATED IN THE GENERAL CONDITIONS AND DMSION 1. ALSO WARRANT THE FOLLOWING ADDITIONAL ITEMS: 1. ALL RACEWAYS ARE FREE FROM OBSTRUCTIONS, HOLES, CRUSHING, OR BREAKS OF ANY NATURE. 2. ALL RACEWAY SEALS ARE EFFECTIVE. 3. THE ENTIRE ELECTRICAL SYSTEM IS FREE FROM ALL SHORT CIRCUITS AND UNWANTED OPEN CIRCUITS AND GROUNDS. THE ABOVE WARRANTIES SHALL INCLUDE LABOR AND MATERIAL MAKE REPAIRS OR REPLACEMENTS WITHOUT ANY ADDITIONAL COSTS TO THE OWNER. PERFORM THE REMEDIAL WORK PROMPTLY, UPON WRITTEN NOTICE FROM THE ENGINEER OR OWNER. AT THE TIME OF SUBSTANTIAL COMPLETION, DELIVER TO THE OWNER ALL WARRANTIES, IN WRITING AND PROPERLY EXECUTED, INCLUDING TERM LIMITS FOR WARRANTIES EXTENDING BEYOND THE ONE YEAR PERIOD. EACH WARRANTY INSTRUMENT BEING ADDRESSED TO THE OWNER AND STATING THE COMMENCEMENT DATE AND TERM. 16A 1 -14 MISCELLANEOUS REMODELING WORK PROVIDE ALL DEMOLITION OF EXISTING ELECTRICAL SYSTEMS AND NEW ELECTRICAL SYSTEM MODIFICATIONS REQUIRED BECAUSE OF BUILDING REMODELING, AS NOTED ON THE DRAWINGS, OR NECESSARY FOR PROPER OPERATION AND NEW CONSTRUCTION. REMOVE ALL ABANDONED CABLES AND WIRING ABOVE ACCESSIBLE CEIUNGS AND VENTILATION SHAFTS. 16A 2 ELECTRICAL WORK 16A 2 -1 BUILDING OPERATION COMPLY WITH THE SCHEDULE OF OPERATIONS AS OUTLINED IN THE ARCHITECTURAL PORTIONS OF THIS SPECIFICATION. BUILDING SHALL BE IN CONTINUOUS OPERATION. ACCOMPLISH WORK THAT REQUIRES INTERRUPTION OF BUILDING OPERATION AT A TIME WHEN THE BUILDING IS NOT IN OPERATION, AND ONLY WITH WRITTEN APPROVAL OF BUILDING OWNER AND /OR TENANT. COORDINATE INTERRUPTION OF BUILDING OPERATION WITH THE OWNER AND /OR TENANT A MINIMUM OF 7 DAYS IN ADVANCE OF WORK. 16A 2-2 EXCAVATION AND BACKFILLING PERFORM EXCAVATION AND BACKFILL REQUIRED FOR INSTALLATION OF UNDERGROUND WORK UNDER THIS CONTRACT. TRENCHES SHALL BE OF SUFFICIENT WIDTH. CRIB OR BRACE TRENCHES TO PREVENT CAVE -IN OR SETTLEMENT. DO NOT EXCAVATE TRENCHES CLOSE TO COLUMNS AND WALLS OF NEW BUILDING WITHOUT PRIOR CONSULTATION WITH THE ENGINEER. USE PUMPING EQUIPMENT IF REQUIRED TO KEEP TRENCHES FREE OF WATER. BACKFILL TRENCHES IN MAXIMUM 6 -INCH LAYERS OF WELL TAMPED DRY EARTH IN A MANNER TO PREVENT FUTURE SLIILEMENT. EXCAVATION AS HEREIN SPECIFIED SHALL BE CLASSIFIED AS COMMON EXCAVATION. COMMON EXCAVATION SHALL COMPRISE THE SATISFACTORY REMOVAL AND DISPOSITION OF MATERIAL OF WHATEVER SUBSTANCES AND OF EVERY DESCRIPTION ENCOUNTERED, INCLUDING ROCK, IF ANY, WITHIN THE LIMITS OF THE WORK AS SPECIFIED AND SHOWN ON THE DRAWINGS. EXCAVATION SHALL BE PERFORMED TO THE UNES AND GRADES INDICATED ON THE DRAWINGS. DISPOSE OF EXCAVATED MATERIALS THAT ARE CONSIDERED UNSUITABLE FOR BACKFILL, AND SURPLUS OF EXCAVATED MATERIAL, WHICH IS NOT REQUIRED FOR BACKFILL, ALL TO THE SATISFACTION OF THE ENGINEER. 16A 2 -3 COINCIDENTAL DAMAGE REPAIR ALL STREETS, SIDEWALKS, DRIVES, PAVING, WALLS, FINISHES, AND OTHER FACILITIES DAMAGED IN THE COURSE OF THIS WORK. REPAIR MATERIALS SHALL MATCH EXISTING CONSTRUCTION. REPAIR MATERIALS SHALL GENERALLY MATCH EXISTING CONSTRUCTION. ALL BACKFILLING AND REPAIRING SHALL MEET ALL REQUIREMENTS OF THE OWNER, CITY AND OTHERS HAVING JURISDICTION. REPAIR WORK SHALL BE THOROUGHLY FIRST CLASS. CONFORM TO ALL REQUIREMENTS OF DMSION 2 OF THESE SPECIFICATIONS. 16A 2 -4 CUTTING AND PATCHING FOLLOWING THE REQUIREMENTS IN DIVISION 1, CUT WALLS, FLOORS, CEILINGS, AND OTHER PORTIONS OF THE FACILITY AS REQUIRED TO PERFORM WORK UNDER THIS DMSION. OBTAIN PERMISSION OF THE ENGINEER, OWNER, OR BOTH, BEFORE DOING ANY CUTTING. CUT ALL HOLES AS SMALL AS POSSIBLE. PATCH WALLS, FLOORS, AND OTHER PORTIONS OF THE FACILTY AS REQUIRED BY WORK UNDER THIS DIVISION. ALL PATCHING SHALL BE THOROUGHLY FIRST CLASS AND SHALL MATCH THE ORIGINAL MATERIAL AND CONSTRUCTION, INCLUDING FIRE RATINGS IF APPLICABLE. 16A 2-5 ROUGH -IN COORDINATE WITHOUT DELAY ALL ROUGHING -IN WITH OTHER DMSIONS. CONCEAL ALL RACEWAYS EXCEPT IN UNFINISHED AREAS AND WHERE OTHERWISE INDICATED ON THE DRAWINGS. 16A 2 -6 SUPPORT SYSTEMS STEEL SLOTTED SUPPORT SYSTEMS (SLOTTED CHANNEL): COMPLY WITH MFMA -3, FACTORY - FABRICATED COMPONENTS FOR FIELD ASSEMBLY; 12- GAUGE, 1 -5/8 -INCH BY 1 -5/8 -INCH; COOPER B -LINE, ERICO INTERNATIONAL CORPORATION, HILTI, INC., POWER- STRUT, THOMAS & BETTS CORPORATION, UNISTRUT. FINISHES: 1. METALUC COATINGS: HOT -DIP GALVANIZED AFTER FABRICATION AND APPLIED ACCORDING TO MFMA -3. 2. FIELD FABRICATION: 1. WHERE FIELD CUTTING OF STANDARD LENGTHS OF CHANNEL ARE REQUIRED, MAKE CUTS STRAIGHT AND PERPENDICULAR TO MANUFACTURED SURFACES. 2. FOR FIELD -CUT OR DAMAGED SURFACES OF COATED CHANNELS, DRESS CUT ENDS, DAMAGED SURFACES, OR BOTH, WITH AN ABRASIVE MATERIAL (E.G., FILE, GRINDING STONE, OR SIMILAR) AND CLEANSER TO REMOVE OILS, RUST, SHARP EDGES AND SHARDS. 3. FOR CHANNEL WITH A FACTORY - APPLIED COATING. RE- FINISH CUT EDGES WITH A COATING COMPATIBLE WITH THE FACTORY FINISH AND AS RECOMMENDED BY THE MANUFACTURER (E.G., MANUFACTURER'S TOUCH -UP PAINT OR ZINC -RICH COLD- GALVANIZING COMPOUND, AS APPUCABLE). 16A 2 -7 PENETRATIONS COORDINATE SLEEVE SELECTION AND APPUCATION WITH SELECTION AND APPLICATION OF FIRE- STOPPING SPECIFIED IN DIVISION 7 SECTION "THROUGH - PENETRATION FIRESTOP SYSTEMS." ROOFS: COORDINATE ALL ROOF PENETRATIONS WITH ENGINEER, OWNER, AND AS APPLICABLE, THE ROOFING CONTRACTOR PROVIDING A ROOF WARRANTY. 2. KEEP ALL RACEWAY PENETRATIONS WITHIN MECHANICAL EQUIPMENT CURBS WHEREVER POSSIBLE. COORDINATE WITH DIVISION 15 WORK. 3. FLASH AND COUNTERFLASH ALL OPENINGS THROUGH ROOF, AND /OR PROVIDE PRE- FABRICATED MOLDED SEALS COMPATIBLE WITH THE ROOF CONSTRUCTION INSTALLED, OR AS REQUIRED BY THE ENGINEER, OWNER, OR ROOFING CONTRACTOR. ALL ROOF PENETRATIONS SHALL BE LEAKTIGHT AT THE TERMINATION OF THE WORK AND SHALL NOT VOID ANY NEW OR EXISTING ROOF WARRANTIES. WALLS AND FLOORS; 1. A. STEEL PIPE SLEEVES: ASTM A 53/A 53M, TYPE E, GRADE B, SCHEDULE 40. GALVANIZED STEEL, PLAIN ENDS AND DRIP RINGS. SLEEVES FOR RACEWAYS AND CABLES B. CAST -IRON PIPE SLEEVES: CAST OR FABRICATED "WALL PIPE," EQUIVALENT TO DUCTILE - IRON PRESSURE PIPE, WITH PLAIN ENDS AND INTEGRAL WATERSTOP, UNLESS OTHERWISE INDICATED. 2. SLEEVES FOR RECTANGULAR OPENINGS: GALVANIZED SHEET STEEL WITH MINIMUM 0.052 - INCH THICKNESS AS INDICATED AND OF LENGTH TO SUIT APPLICATION. 16B 2 -8 FIRF- STOPPING THROUGH PENETRATIONS FIRE- RESISTANT THROUGH PENETRATION SEALANTS: TWO -PART, FOAMED -IN- PLACE, SIUCONE SEALANT FORMULATED FOR USE IN THROUGH- PENETRATION FIRE - STOPPING AROUND CABLES, RACEWAYS, AND CABLE TRAY PENETRATIONS THROUGH FIRE -RATED WALLS AND FLOORS. SEALANTS AND ACCESSORIES SHALL HAVE FIRE- RESISTANCE RATINGS INDICATED, AS ESTABLISHED BY TESTING IDENTICAL ASSEMBLIES IN ACCORDANCE WFTH ASTM E 814, BY UNDERWRITERS' LABORATORIES, INC„ OR OTHER NRTL ACCEPTABLE TO AHJ. 1. ACCEPTABLE MANUFACTURERS: A. HILTI, INC. B. 3M CORP. C. RECTORSEAL. D. SPECIFY TECHNOLOGY INC. E. UNITED STATES GYPSUM COMPANY. 16A 2 -9 ACCESS DOORS PROVIDE ACCESS DOORS IN CEILINGS AND WALLS, WHERE INDICATED OR REQUIRED FOR ACCESS OR MAINTENANCE TO CONCEALED EQUIPMENT INSTALLED UNDER THIS SECTION. PROVIDE CONCEALED HINGES, SCREWDRIVER -TYPE LOCK, AND ANCHOR STRAPS. MANUFACTURED BY MILCOR, ZURN, TITUS, OR EQUAL OBTAIN ARCHITECT'S APPROVAL OF TYPE, SIZE, LOCATION AND COLOR BEFORE ORDERING. 16A 2 -10 EQUIPMENT FURNISHED BY OTHERS PROVIDE NECESSARY EQUIPMENT AND ACCESSORIES THAT ARE NOT PROVIDED BY THE EQUIPMENT SUPPLIER OR OWNER TO COMPLETE INSTALLATION OF EQUIPMENT FURNISHED BY OTHERS, IN LOCATIONS AS INDICATED ON THE DRAWINGS, SPECIFIED HEREIN, OR BOTH. EQUIPMENT AND ACCESSORIES NOT PROVIDED BY THE EQUIPMENT SUPPLIER MAY INCLUDE SUCH ITEMS AS FLEXIBLE CORDS AND PLUGS, AS REQUIRED FOR PROPER OPERATION OF THE COMPLETE SYSTEM, IN ACCORDANCE WITH THE MANUFACTURERS' INSTRUCTIONS. BE RESPONSIBLE FOR CORRECT ROUGH -IN DIMENSIONS, AND VERIFY THEM WITH ENGINEER. OWNER'S REPRESENTATIVE, EQUIPMENT SUPPLIER, OR ALL THREE, PRIOR TO ROUGH -IN AND SERVICE INSTALLATIONS. 16A 2 -11 CLEANING IN ADDITION TO THE REQUIREMENTS OF DIVISION 1, REMOVE FROM THE PREMISES DIRT AND REFUSE RESULTING FROM THE PERFORMANCE OF THE ELECTRICAL WORK, AS REQUIRED, TO PREVENT ACCUMULATION. COOPERATE IN MAINTAINING REASONABLY CLEAN PREMISES AT ALL TIMES. IMMEDIATELY PRIOR TO FINAL INSPECTION, MAKE A FINAL CLEANUP OF DIRT AND REFUSE RESULTING FROM THE WORK. CLEAN ALL MATERIAL AND EQUIPMENT INSTALLED UNDER THIS DIVISION. REMOVE DIRT, DUST, PLASTER, STAINS AND FOREIGN MATTER FROM ALL SURFACES. TOUCH UP AND RESTORE ALT. DAMAGED FINISHES TO THEIR ORIGINAL CONDITION. 16A 2 -12 ADJUSTING, ALIGNING AND TESTING ADJUST, ALIGN, AND TEST ALL ELECTRICAL EQUIPMENT ON THIS PROJECT PROVIDED UNDER THIS DIVISION AND ALL ELECTRICAL EQUIPMENT FURNISHED BY OTHERS FOR INSTALLATION OR WIRING UNDER THIS DIVISION, FOR PROPER OPERATION. TEST ALL SYSTEMS AND EQUIPMENT ACCORDING TO THE REQUIREMENTS IN NETA ATS (LATEST EDITION) AND ALL ADDITIONAL REQUIREMENTS SPECIFIED IN FOLLOWING SECTIONS. MAINTAIN THE FOLLOWING ON THE PROJECT PREMISES AT ALL TIMES: A TRUE RMS READING VOLTMETER, A TRUE RMS READING AMMETER, AND A MEGOHMMETER INSULATION RESISTANCE TESTER. PROVIDE TEST DATA READINGS AS REQUESTED OR AS REQUIRED BY THE ENGINEER. 16A 2 -13 EQUIPMENT IDENTIFICATION PROVIDE EQUIPMENT IDENTIFICATION NAMEPLATES: 1. ON ALL PANELBOARDS, SWITCHES, STARTERS, DIMMERS, SWITCHES IN DISTRIBUTION PANELBOARDS AND SWITCHBOARDS. NAMEPLATES: 1. ENGRAVED, CONTRASTING COLOR, THREE - LAYER, LAMINATED PLASTIC INDICATING THE NAME OF THE EQUIPMENT, LOAD, OR CIRCUIT AS DESIGNATED ON THE DRAWINGS AND IN THE SPECIFICATIONS: 2. SELF - ADHERING, WITH A PERMANENT, WEATHERPROOF ADHESIVE 3. ATTACHMENT METHOD SHALL BE ACCEPTABLE TO THE MANUFACTURERS OF THE EQUIPMENT TO WHICH THE NAMEPLATES ARE BEING APPLIED. 4. COLOR: BLACK BACKGROUND WITH WHITE LETTERS. LETTER HEIGHT: 1/4-INCH MINIMUM. 16A 2 -14 SYSTEM START UP PRIOR TO STARTING UP THE ELECTRICAL SYSTEMS: 1. CHECK ALL COMPONENTS AND DEVICES. 2. LUBRICATE ITEMS ACCORDINGLY. 3. TIGHTEN SCREWS AND BOLTS FOR CONNECTORS AND TERMINALS ACCORDING TO MANUFACTURER'S PUBLISHED TORQUE - TIGHTENING VALUES. IF MANUFACTURER'S TORQUE VALUES ARE NOT INDICATED, USE THOSE SPECIFIED IN UL 486A [AND UL 486B]. 4. ADJUST TAPS ON EACH TRANSFORMER FOR RATED SECONDARY VOLTAGE. 5. CHECK AND RECORD BUILDING'S SERVICE ENTRANCE VOLTAGE, GROUNDING CONDITIONS. GROUNDING RESISTANCE, AND PROPER PHASING. 6. BALANCE ALL SINGLE -PHASE LOADS AT EACH PANELBOARD, REDISTRIBUTING BRANCH CIRCUIT CONNECTIONS UNTIL BALANCE IS ACHIEVED. DO NOT TYPE UP FINAL PANELBOARD DIRECTORIES UNTIL ALL RE- BALANCING AND REDISTRIBUTION OF CIRCUITS ARE COMPLETE. 7. REPLACE ALL BURNED -OUT LAMPS AND LAMPS USED FOR TEMPORARY CONSTRUCTION LIGHTING IN PERMANENT UGHT FIXTURES. 8. AFTER ALL SYSTEMS HAVE BEEN INSPECTED AND ADJUSTED, CONFIRM ALL OPERATING FEATURES REQUIRED BY THE DRAWINGS AND SPECIFICATIONS AND MAKE FINAL ADJUSTMENTS AS NECESSARY. 16A 3 EXISTING EQUIPMENT REUSE AND REMOVAL REMOVE ALL EXISTING WIRING. UGHT FIXTURES. EXPOSED CONDUITS AND OTHER ELECTRICAL INSTALLATIONS NOT REUSED PRIOR TO SUBSTANTIAL COMPLETION OF THE WORK. EXISTING RACEWAYS MAY BE REUSED IF THEIR POINTS OF TERMINATIONS ARE SUITABLE; IF THEY ARE CLEAN INSIDE WITH NO EVIDENCE OF RUST OR BURRS; IF FREE FROM CRACKS, FLATTENED SECTIONS OR SHARP BENDS; AND, IF SUITABLY LOCATED TO AVOID CONFLICTS WITH OTHER TRADES OR INSTALLATIONS. CAREFULLY "FISH" ALL EXISTING CONDUITS REUSED UNDER THIS CONTRACT TO REMOVE ALL DEBRIS AND OBSTRUCTIONS, AND SWAB UNTIL ALL MOISTURE IS REMOVED. CUT. PATCH, AND REPAIR WHERE REQUIRED FOR NEW ELECTRICAL INSTALLATIONS. AND PATCH AND REPAIR ALL SURFACE DAMAGE RESULTING FROM THIS WORK. CUT FLUSH WITH THE FLOOR AND PLUG AT BOTH ENDS, RACEWAYS STUBBED ABOVE THE FLOOR AND NOT USED AT SUBSTANTIAL COMPLETION OF THE WORK. RELOCATE ALL EXISTING ELECTRICAL SYSTEMS REQUIRED TO BE IN OPERATION AT SUBSTANTIAL COMPLETION OF THE CONTRACT, IF REQUIRED, AS A RESULT OF WORK INCLUDED UNDER THIS CONTRACT. EVEN IF NOT SPECIFICALLY INDICATED IN THE DRAWINGS OR SPECIFICATIONS. SECTION 16B BASIC ELECTRICAL MATERIALS AND METHODS 1613 1 METHODS 16B 1 -1 RACEWAYS METALLIC CONDUIT: 1. ELECTRICAL METALLIC TUBING AND FITTINGS (EMT): ANSI C80.3, UL 797. 2. FLEXIBLE METAL CONDUIT (FMC): ZINC - COATED STEEL OR ALUMINUM, UL 1. 3. INTERMEDIATE METAL CONDUIT (IMC): HOT-DIP GALVANIZED RIGID STEEL CONDUIT: ANSI C80.6, UL 1242. 4. UQUIDTIGHT FLEXIBLE METAL CONDUIT (LFMC): FLEXIBLE STEEL CONDUIT WITH PVC JACKET: UL 360 5. RIGID METAL CONDUIT (RMC): HOT -DIP GALVANIZED RIGID STEEL CONDUIT (GRS): ANSI C80.1, UL 6. 6. RIGID ALUMINUM CONDUIT (RAC): ANSI C80.5, UL 6A. 7. PLASTIC - COATED IMC, RMC, AND FITTINGS: NEMA RN 1, UL LISTED. 8. IMC AND RMC FITTINGS: NEMA FB 1; COMPATIBLE WITH CONDUIT TYPE AND MATERIAL, UL LISTED NON- METALLIC CONDUIT AND TUBING: 1. RIGID NONMETALLIC CONDUIT (RNC): SCHEDULE 40 PVC, 90 DEG C RATED, NEMA TC -2, UL 651; FITTINGS: NEMA TC 3, TC 6; UL 514, COMPATIBLE WITH CONDUIT TYPE AND MATERIAL, UL LISTED. 16B 1 -2 RACEWAY INSTALLATION INSTALL ALL CIRCULAR RACEWAYS CONCEALED ABOVE SUSPENDED CEILINGS OR CONCEALED IN WALLS OR FLOORS WHEREVER POSSIBLE EXCEPT WHERE OTHERWISE INDICATED. PROVIDE GRS FOR ALL CONDUITS RUN UNDERGROUND, EXPOSED TO WEATHER, OR EXPOSED TO OTHER HAZARDOUS CONDITIONS. PROVIDE GRS INSTALLED BELOW GRADE WITH A CORROSION RESISTANT BONDED - PLASTIC OR APPROVED MASTIC COATING. THIS SHALL INCLUDE THE 90- DEGREE ELBOW BELOW GRADE AND THE ENTIRE VERTICAL TRANSITION TO ABOVE GRADE. ALL OTHER RACEWAY MAY BE EMT WHERE APPROVED BY LOCAL CODE. USE COMPRESSION TYPE FITTINGS FOR EMT, WITH ALL FITTINGS UL LISTED FOR THE ENVIRONMENT IN WHICH THEY ARE USED. AT CONTRACTOR'S OPTION, PVC CONDUIT MAY BE USED UNDERGROUND WHERE PERMITTED BY LOCAL CODE AND WHERE NOT SPECIFICALLY RESTRICTED BY THESE DOCUMENTS. WHEN USED, PROVIDE COATED GRS, AS SPECIFIED ABOVE, FOR ALL BENDS GREATER THAN 30 DEGREES, INCLUDING THE 90- DEGREE ELBOWS BELOW GRADE AND THE ENTIRE VERTICAL RISERS FOR TRANSITIONS FROM BELOW TO ABOVE GRADE OR ABOVE -SLAB. USE FMC FOR FINAL CONNECTION TO EACH MOTOR AND TRANSFORMER, AND TO ANY DEVICE THAT WOULD OTHERWISE TRANSMIT MOTION, VIBRATION, OR NOISE. USE LFMC WHERE EXPOSED TO UQUIDS, VAPORS OR SUNLIGHT, AND TO CONNECT TO KITCHEN AND FOOD SERVICE EQUIPMENT. PROVIDE ALL FMC AND LFMC WITH AN INSULATED BONDING CONDUCTOR. USE ONLY METAL RACEWAYS FOR ALL POWER WIRING FROM THE OUTPUT OF VARIABLE FREQUENCY DRIVES TO THEIR RESPECTIVE MOTORS. INSTALL RACEWAYS PARALLEL AND PERPENDICULAR TO BUILDING LINES. INSTALL RACEWAYS TO REQUIREMENTS OF STRUCTURE AND TO REQUIREMENTS OF ALL OTHER WORK ON THE PROJECT. INSTALL RACEWAY TO CLEAR ALL OPENINGS, DEPRESSIONS. PIPES, DUCTS, REINFORCING STEEL, AND OTHER IMMOVABLE OBSTACLES. INSTALL RACEWAYS SET IN FORMS FOR CONCRETE STRUCTURE IN SUCH A MANNER THAT INSTALLATION WILL NOT AFFECT THE STRENGTH OF THE STRUCTURE. EXCEPT WHERE APPROVED IN WRITING BY THE ENGINEER, INSTALL NO RACEWAY IN A SLAB -ON- GRADE. LOCATE RACEWAY IN GRANULAR FILL BELOW SLABS -ON- GRADE. INSTALL RACEWAYS CONTINUOUS BETWEEN CONNECTIONS TO OUTLETS, BOXES AND CABINETS WITH A MINIMUM POSSIBLE NUMBER OF BENDS AND NOT MORE THAN THE EQUIVALENT OF FOUR 90- DEGREE BENDS BETWEEN CONNECTIONS. USE MANUFACTURED ELBOWS FOR ALL 45- AND 90- DEGREE BENDS, UNLESS APPROVED BY THE ENGINEER IN ADVANCE. MAKE OTHER BENDS SMOOTH AND EVEN AND WITHOUT FLATTENING RACEWAY OR FLAKING GALVANIZING OR ENAMEL RADII OF BENDS SHALL BE AS LONG AS POSSIBLE AND NEVER SHORTER THAN THE CORRESPONDING TRADE ELBOW. USE LONG RADIUS ELBOWS WHERE NECESSARY, INDICATED, OR BOTH. SECURELY FASTEN RACEWAYS IN PLACE WITH APPROVED STRAPS, HANGERS AND STEEL SUPPORTS AS REQUIRED. ATTACH RACEWAY SUPPORTS TO THE BUILDING STRUCTURE. HANG SINGLE RACEWAYS FOR FEEDERS WITH MALLEABLE SPLIT RING HANGERS WITH ROD AND TURNBUCKLE SUSPENSION FROM INSERTS SPACED NOT OVER 10 FEET APART IN CONSTRUCTION ABOVE. CLAMP GROUPS OF HORIZONTAL FEEDER RACEWAYS TO STEEL CHANNELS THAT ARE SUSPENDED FROM INSERTS SPACED NOT OVER 10 FEET APART IN CONSTRUCTION ABOVE. SECURELY CLAMP VERTICAL FEEDER RACEWAYS TO STRUCTURAL STEEL MEMBERS ATTACHED TO STRUCTURE. INSTALL CABLE CLAMPS FOR SUPPORT OF VERTICAL FEEDERS WHERE REQUIRED. ADD RACEWAY SUPPORTS WITHIN 12 INCHES OF ALL BENDS, ON BOTH SIDES OF THE BENDS. DO NOT SUPPORT RACEWAYS FROM SUSPENDED CEIUNG COMPONENTS. REAM RACEWAY ENDS, THOROUGHLY CLEAN RACEWAYS BEFORE INSTALLATION, AND KEEP CLEAN AFTER INSTALLATION. PLUG OR COVER OPENINGS AND BOXES AS REQUIRED TO KEEP RACEWAYS CLEAN DURING CONSTRUCTION AND FISH ALL RACEWAYS CLEAR OF OBSTRUCTIONS BEFORE PULLING CONDUCTORS WIRES. PROVIDE RACEWAYS OF AMPLE SIZE FOR PUWNG OF WIRE AND NOT SMALLER THAN CODE REQUIREMENTS AND NOT LESS THAN 1/2 -INCH IN SIZE, UNLESS INDICATED OTHERWISE ON DRAWINGS. PROTECT ALL RACEWAY INSTALLATIONS AGAINST DAMAGE DURING CONSTRUCTION. REPAIR ALL RACEWAYS DAMAGED OR MOVED OUT OF UNE AFTER ROUGHING -IN TO MEET ENGINEER'S APPROVAL WITHOUT ADDITIONAL COST TO THE OWNER. AUGN AND INSTALL TRUE AND PLUMB ALL RACEWAY TERMINATIONS AT PANELBOARDS, SWITCHBOARDS, MOTOR CONTROL EQUIPMENT AND JUNCTION BOXES. INSTALL APPROVED EXPANSION /DEFLECTION FITTINGS WHERE RACEWAYS PASS THROUGH (IF EMBEDDED) OR ACROSS (IF EXPOSED) EXPANSION JOINTS. INSTALL A PULL WIRE IN EACH EMPTY RACEWAY THAT IS LEFT FOR INSTALLATION OF CONDUCTORS OR CABLES UNDER OTHER DIVISIONS OR CONTRACTS. USE POLYPROPYLENE OR MONOFILAMENT PLASTIC LINE WITH NOT LESS THAN 200 -LB TENSILE STRENGTH. LEAVE AT LEAST 24 INCHES OF SLACK AT EACH END OF PULL WIRE. MAKE ALL JOINTS AND CONNECTIONS IN A MANNER THAT WILL. ENSURE MECHANICAL STRENGTH AND ELECTRICAL CONTINUITY. EFFECTIVELY SEAL RACEWAYS, BY INSTALLING A CONDUIT I-11 IING AT THE BOUNDARY OF THE TWO SPACES, AND FILLING IT WITH AN APPROVED PLIABLE MATERIAL. AFTER CONDUCTORS OR CABLES HAVE BEEN INSTALLED AND TESTED, WHEN EVER: 1. RACEWAYS PASS FROM NON- COOLED TO COOLED SPACES. 2. RACEWAYS TRANSITION FROM OUTSIDE A FACILITY OR ENCLOSURE TO INSIDE, WHETHER BURIED OR EXPOSED. R `E :V D CT 15nil r Le el4tl 1 CEN I (=f( Type of Device Hubbell Pass & Seymour Levi Cooper Wiring Devices Simplex Receptacle HH1 5351.____ 5362 -GY _5.6191._ 5352 5352 5351 Duplex Receptacle 5352 GFCI Receptacle GFR5352 -GYA 2091 6898/6598 XGF20 Safety Receptacle (20A / 125V) HBL8300SG TR63 8300 -SC TR $300 Isolated Ground (IG) RP.CP.p IG5362 -GY IG6300 8300 -IG 105362 Quad /4 -Plex HBL 420 420 21254 N/A 9991 Single Pole Switch CS1991 -GY PS 90 ACI 1791 -2 Double Pole Switch CS1222 PS 20AC2 1222 -2 2222 Three -way Switch 5x1223 SzL P5.20AC3._._.._ 1223-2_ 2223 Four -way Switch CS1224 PS 20AC4 _. 1224 -2 2224 PROJ. DRWN. DATE 2007 -0174 EC 9 -25 -07 Momentary SPDT, Center -Off Switch HBL 1557 1251 E7 1995 27 OF 27 Type of Device Hubbell Pass & Seymour Levi Cooper Wiring Devices Simplex Receptacle HH1 5351.____ 5362 -GY _5.6191._ 5352 5352 5351 Duplex Receptacle 5352 GFCI Receptacle GFR5352 -GYA 2091 6898/6598 XGF20 Safety Receptacle (20A / 125V) HBL8300SG TR63 8300 -SC TR $300 Isolated Ground (IG) RP.CP.p IG5362 -GY IG6300 8300 -IG 105362 Quad /4 -Plex HBL 420 420 21254 N/A 9991 Single Pole Switch CS1991 -GY PS 90 ACI 1791 -2 Double Pole Switch CS1222 PS 20AC2 1222 -2 2222 Three -way Switch 5x1223 SzL P5.20AC3._._.._ 1223-2_ 2223 Four -way Switch CS1224 PS 20AC4 _. 1224 -2 2224 SP3W. Inca ndescent Momentary SPDT, Center -Off Switch HBL 1557 1251 1257 1995 16B 1 -3 BUSHINGS AND LOCKNUTS RIGIDLY TERMINATE CONDUITS ENTERING SHEET METAL ENCLOSURES TO THE ENCLOSURE WITH A BUSHING AND LOCKNUT ON THE INSIDE AND A LOCKNUT OR AN APPROVED HUB THE OUTSIDE. CONDUIT SHALL ENTER THE ENCLOSURE SQUARELY. PROVIDE BUSHINGS AND LOCKNUTS MADE OF GALVANIZED MALLEABLE IRON WITH SHARP, CLEAN -CUT THREADS. WHERE EMT ENTERS A BOX, PROVIDE APPROVED EMT COMPRESSION CONNECTORS. USE INSULATED. GROUNDING, OR COMBINATION. BUSHINGS WHEREVER CONNECTION IS SUBJECT TO VIBRATION OR MOISTURE, WHEN REQUIRED BY NFPA 70, OR BOTH. 16B 1 -4 CONDUCTORS AND CABLES CONDUCTOR MATERIAL: 1. ANNEALED (SOFT) COPPER COMPLYING WITH ICEA S -95- 658 /NEMA WC70; 2. CONDUCTOR INSULATION TYPES: 90- DEGREE C- RATED, TYPE THHN/THWN -2 OR XHHW -2 COMPLYING WITH ICEA S -95- 658 /NEMA WC70. 3. SIZES OF CONDUCTORS AND CABLES INDICATED OR SPECIFIED ARE IN AMERICAN WIRE GAGE (AWG - BROWN AND SHARPE). 4. UNLESS INDICATED OTHERWISE. SPECIAL PURPOSE CONDUCTORS AND CABLES, SUCH AS LOW VOLTAGE CONTROL AND SHIELDED INSTRUMENT WIRING, SHALL BE AS RECOMMENDED BY THE SYSTEM EQUIPMENT MANUFACTURER. ALL FEEDER AND BRANCH CIRCUIT CONDUCTORS NO. 8 AWG AND LARGER: STRANDED, TYPE THWN -2 OR XHHW -2 INSULATION. ALL CONDUCTORS, NO. 10 AWG AND SMALLER, USED FOR POWER AND LIGHTING CIRCUITS: SOLID COPPER, TYPE THWN -2 (WET OR DAMP LOCATIONS, OR IN CONDUIT BELOW GRADE OR SLAB), TYPE THHN (DRY LOCATIONS ONLY AND ABOVE GRADE) INSULATION, OR DUAL -RATED TYPE THHN/THWN-2. ALL BRANCH CIRCUIT WIRING: NOT SMALLER THAN NO. 12 AWG. IF NO CONDUCTOR SIZE IS INDICATED ON THE DRAWINGS FOR A BRANCH CIRCUIT, PROVIDE CONDUCTORS AND CONDUIT SIZED PER NFPA 70 AND BASED ON THE INDICATED BRANCH CIRCUIT OVERCURRENT PROTECTIVE DEVICE (OCPD) RATING AND NUMBER OF POLES. WHERE NO CIRCUIT SIZE (I.E., CONDUCTORS AND OCPD) IS INDICATED ON THE DRAWINGS FOR A BRANCH CIRCUIT, PROVIDE THREE NO. 12 AWG CONDUCTORS, IN 3/4 -INCH RACEWAY, AND A 20A CIRCUIT BREAKER. CONDUCTORS FIELD - INSTALLED WITHIN FLUORESCENT LIGHT FIXTURE CHANNELS: TYPE THHN. CONTROL WIRING: STRANDED COPPER CONDUCTORS, 600V INSULATION, OF THE PROPER TYPE, SIZE AND NUMBER AS REQUIRED TO ACCOMPLISH SPECIFIED FUNCTION. MINIMUM SIZE: NO. 14 AWG, UNLESS NOTED OTHERWISE. TYPE MC CABLE: 600V, UNJACKETED; ANSI E119 AND E814, UL STANDARDS 44 OR 83 (AS APPLICABLE), AND 1569, NFPA 70 ARTICLE 330; ALUMINUM OR GALVANIZED STEEL INTERLOCKED ARMOR; THHN- OR XHHW - INSULATED CONDUCTORS; COLOR CODE: ICEA METHOD 1, WITH GREEN INSULATED GROUNDING CONDUCTOR 16B 1 -5 INSTALLATION OF CONDUCTORS AND CABLES INSTALL ALL WIRING IN APPROVED RACEWAY AND ENCLOSURES. SUPPORT ALL CONDUCTORS AND CABLES IN VERTICAL INSTALLATIONS. AS REQUIRED BY NFPA 70, BY INSTALLING CABLE SUPPORTS OR PLUG -TYPE CONDUIT RISER SUPPORTS, OR WIRE -MESH SAFETY GRIPS. INSTALL ALL CONDUCTORS AND CABLE IN RACEWAYS CONTINUOUS WITHOUT TAPS OR SPLICES. SPLICE OR TAP ONLY IN APPROVED BOXES AND ENCLOSURES WITH APPROVED SOLDERLESS CONNECTORS. OR CRIMP CONNECTORS AND TERMINAL BLOCKS FOR CONTROL WIRING, AND KEEP TO THE MINIMUM REQUIRED. INSULATE ALL SPLICES, TAPS. AND JOINTS AS REQUIRED BY CODES. ALL MATERIALS USED TO TERMINATE, SPUCE OR TAP CONDUCTORS: DESIGNED FOR, PROPERLY SIZED FOR, AND UL LISTED FOR THE SPECIFIC APPLICATION AND CONDUCTORS INVOLVED, AND INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, USING THE MANUFACTURER'S RECOMMENDED TOOLS. WHERE WIRING 15 INDICATED AS INSTALLED, BUT THE CONNECTION IS INDICATED "FUTURE" OR "BY OTHER DIVISION, TRADES, OR CONTRACTS ", LEAVE A MINIMUM 3 -FOOT "PIGTAIL" AT THE BOX, TAPE THE ENDS OF THE CONDUCTORS, AND COVER THE BOX. THE NUMBER OF CONDUCTORS IN A SPECIFIC RACEWAY "HOME RUN" IS INDICATED WITH CROSS UNES (TICK MARKS) ON EACH "CIRCUIT RUN" ON THE DRAWINGS. IN GENERAL, THE DIRECTION OF BRANCH CIRCUIT "HOME RUN" ROUTING IS INDICATED ON THE DRAWINGS, COMPLETE WITH CIRCUIT NUMBERS AND PANELBOARD DESIGNATION. CONTINUE ALL SUCH "HOME RUN" WIRING TO THE DESIGNATED PANELBOARD, AS THOUGH "CIRCUIT RUNS" WERE INDICATED IN THEIR ENTIRETY. WHEN MULTIPLE HOME RUNS ARE COMBINED INTO A SINGLE RACEWAY SUCH THAT THE NUMBER OF CONDUCTORS EXCEEDS FOUR (CONDUCTOR COUNT 15 MADE UP OF ANY COMBINATION OF PHASE AND NEUTRAL CONDUCTORS), THE FOLLOWING RESTRICTIONS APPLY, WHICH ARE IN ADDITION TO THOSE IN NFPA 70: 1. NORMAL OR NON - ESSENTIAL CIRCUITS. A. MAXIMUM OF 16 CONDUCTORS IN A SINGLE RACEWAY. FOR UP TO EIGHT CONDUCTORS IN A RACEWAY, MINIMUM RACEWAY SIZE: 3/4 -INCH. FOR GREATER THAN EIGHT CONDUCTORS, MINIMUM RACEWAY SIZE: 1 -INCH. DO NOT INSTALL ANY OTHER TYPE OF CIRCUIT IN THIS RACEWAY. B. C. 2. A. THE MINIMUM WIRE SIZE FOR ALL CONDUCTORS IN THIS RACEWAY: NO. 10 AWG. ONLY 15A AND 20A BRANCH CIRCUIT HOMERUNS MAY BE COMBINED INTO ONE RACEWAY. GFCI CIRCUITS. DO NOT USE MULTI - CONDUCTOR CIRCUITS, WITH A SHARED NEUTRAL, FOR ANY GFCI CIRCUIT BREAKER OR RECEPTACLE CIRCUIT. FOR BRANCH CIRCUITS FED FROM GFCI CIRCUIT BREAKERS, LIMIT THE ONE-WAY CONDUCTOR LENGTH TO 100 FEET BETWEEN THE PANELBOARD AND THE MOST REMOTE RECEPTACLE OR LOAD ON THE GFCI CIRCUIT. WIRING SHALL HAVE INSULATION OF THE PROPER COLOR TO MATCH COLOR CODE SYSTEM IN THE TABLE BELOW. IN LARGER SIZES, WHERE PROPERLY COLORED INSULATION 15 NOT AVAILABLE, USE VINYL PLASTIC ELECTRICAL TAPE OF THE APPROPRIATE COLOR AROUND EACH CONDUCTOR AT ALL TERMINATION POINTS, JUNCTION AND PULL BOXES. System Voltage Conductor Type 208Y/120 PHASE A PHASE B PHASE C NEUTRAL EQUIPMENT GROUND ISOLATED GROUND Color BLACK RED BLUE WHITE GREEN GREEN MIL YELLO TRIPES 1. IN LIEU OF FLEXIBLE CONDUIT AND WIRING FROM LIGHT FIXTURES IN ACCESSIBLE CEILINGS TO JUNCTION BOXES (ATTACHED TO BUILDING STRUCTURE) ABOVE THE CEILING. PROVIDE CABLE WHIPS OF SUFFICIENT LENGTHS TO ALLOW FOR RELOCATING EACH LIGHT FIXTURE WITHIN A 5 -FOOT RADIUS OF ITS INSTALLED LOCATION, BUT NOT EXCEEDING 6 FEET IN UNSUPPORTED LENGTHS. 2. FOR VERTICAL DROPS IN STUD WALLS. 3. IN LIEU OF EMT, ONLY FOR 15A AND 20A BRANCH CIRCUITS (WITH UP TO FOUR (4) CONDUCTORS, NOT INCLUDING GROUND CONDUCTOR), AND ONLY IN DRY CONCEALED LOCATIONS ABOVE GRADE, EXCEPT WHERE SPECIFICALLY NOT PERMITTED BY NFPA 70. 4. DO NOT USE MC CABLE FOR THE FOLLOWING: A. HOMERUNS TO PANELBOARDS. B. WHERE EXPOSED TO VIEW. C. WHERE EXPOSED TO DAMAGE. D. HAZARDOUS LOCATIONS. E. WET LOCATIONS. F. WHEN RESTRICTED OTHERWISE ABOVE. AND WHEN SPECIFICALLY DISALLOWED BY THE LOCAL AHJ, LANDLORD, OR BOTH. PROPERLY IDENTIFY ALL TERMINAL BLOCKS AND WIRE TERMINALS FOR CONTROL WIRING WITH VINYL STICK -ON MARKERS OR EQUIVALENT. PROVIDE ENGINEER WITH A LIST OF PROPOSED IDENTIFYING NUMBERS FOR REVIEW PRIOR TO INSTALLING MARKERS. PROVIDE AN EQUIPMENT - GROUNDING CONDUCTOR, OR BONDING JUMPER, AS APPLICABLE, IN ALL FEEDER AND NON - UGHTING BRANCH CIRCUITS. SIZED IN ACCORDANCE WITH NFPA 70 TABLES 250.66 OR 250.122, AS APPUCABLE, UNLESS INDICATED AS LARGER ON THE DRAWINGS. PROVIDE AN EQUIPMENT - GROUNDING CONDUCTOR, OR BONDING JUMPER, AS APPLICABLE, IN ALL BRANCH CIRCUITS AND FEEDERS, SIZED IN ACCORDANCE WITH NFPA 70 TABLES 250.66 OR 250.122, AS APPLICABLE, UNLESS INDICATED AS LARGER ON THE DRAWINGS. VOLTAGE DROP IN BRANCH CIRCUITS SHALL NOT EXCEED 3 PERCENT. 16B 1 -6 JUNCTION BOXES. PULL BOXES. CABINETS AND WIREWAYS PROVIDE JUNCTION BOXES, PULL BOXES, CABINETS AND WIREWAYS WHEREVER NECESSARY ON FOR PROPER INSTALLATION OF VARIOUS ELECTRICAL SYSTEMS ACCORDING TO NFPA 70 AND WHERE INDICATED ON THE DRAWINGS. SIZE AS REQUIRED FOR THE SPECIFIC FUNCTION OR AS REQUIRED BY NFPA 70, WHICHEVER IS LARGER. CONSTRUCTION SHALL BE OF A NEMA DESIGN SUITABLE FOR THE ENVIRONMENT INSTALLED. JUNCTION BOXES INSTALLED BEHIND WALL CASES, AND IN OR ON OTHER STORE FIXTURES, EXCEPT WHERE OTHERWISE SPECIFIED, SHALL BE 4 -INCH SQUARE OR LARGER, WITH GALVANIZED COVERS. HORIZONTALLY MOUNT JUNCTION BOXES UNDER CENTER FIXTURES (AND CASES), HANDY BOXES OR 4 -INCH SQUARE BOXES WITH TOPS OF BOXES NOT MORE THAN 3 -1/2 INCHES ABOVE THE FLOOR. SIZE JUNCTION BOXES TO ADEQUATELY CONTAIN ALL REQUIRED CONDUCTORS AND SPLICES. 16B 1 -7 OUTLET BOXES ALL OUTLETS INCLUDING LIGHT FIXTURE, SWITCH, RECEPTACLE, AND SIMILAR OUTLETS: NATIONAL ELECTRICAL, APPLETON, STEEL CITY, RACO, OR APPROVED EQUAL GALVANIZED STEEL KNOCKOUT BOXES, SUITABLE IN DESIGN TO THE PURPOSE THEY SERVE AND THE SPACE THEY OCCUPY. SIZE AS REQUIRED FOR THE SPECIFIC FUNCTION OR AS REQUIRED BY NFPA 70, WHICHEVER 15 LARGER. SET ALL OUTLET BOXES IN WALLS, COLUMNS, FLOORS, OR CEILINGS 50 THEY ARE FLUSH WITH THE FINISHED SURFACE, ACCURATELY SET, AND RIGIDLY SECURED IN POSITION. PROVIDE PLASTER RINGS, EXTENSION RINGS AND /OR MASONRY RINGS AS REQUIRED FOR FLUSH MOUNTING. PROVIDE APPROVED CAST OUTLET BOXES, WITH HUBS AND WEATHERPROOF COVERS, IN ALL AREAS SUBJECT TO DAMP, WET, OR HARSH CONDITIONS. 16B 1 -8 OUTLET LOCATIONS COORDINATE LOCATIONS OF OUTLET BOXES. OUTLETS ARE ONLY APPROXIMATELY LOCATED ON THE SMALL SCALE DRAWINGS. USE GREAT CARE IN THE ACTUAL LOCATION BY CONSULTING THE VARIOUS LARGE SCALE DETAILED DRAWINGS USED BY OTHER DIVISION TRADES, AND BY SECURING DEFINITE LOCATIONS FROM THE ARCHITECT. 16B 1 -9 MOUNTING HEIGHTS UNLESS NOTED OTHERWISE, INSTALL WIRING DEVICES AS INDICATED BELOW (NOTE: ALL DIMENSIONS ARE TO THE BOTTOM OF THE OUTLET BOX UNLESS NOTED OTHERWISE): RECEPTACLES: 1. GENERAL: A. VERTICALLY WITH THE GROUND SLOT MOUNTED AT THE TOP: 16 INCHES ABOVE FINISHED FLOOR. 2. ABOVE COUNTERS: A. FOR 36 -INCH HIGH COUNTER TOPS: 44 INCHES ABOVE FINISHED FLOOR, VERTICALLY. B. FOR 34 --INCH HIGH COUNTER TOPS: 40 INCHES ABOVE FINISHED FLOOR, VERTICALLY. 3. MECHANICAL AND ELECTRICAL EQUIPMENT ROOMS AND JANITORS CLOSETS: 44 INCHES ABOVE FINISHED FLOOR, VERTICALLY. 4. GFCI RECEPTACLES: SAME AS GENERAL RECEPTACLES. 5. ISOLATED GROUND RECEPTACLES: SAME AS GENERAL RECEPTACLES. 6. CONCRETE BLOCK WALLS: DIMENSIONS ABOVE MAY BE ADJUSTED SLIGHTLY, AS REQUIRED TO COMPENSATE FOR VARIABLE JOINT DIMENSIONS, SUCH THAT BOTTOM OR TOP OF BOXES, AS APPUCABLE, ARE AT BLOCK JOINTS. SWITCHES: 1. GENERAL: 44 INCHES ABOVE FINISHED FLOOR. 2. ABOVE COUNTERS: SAME AS FOR RECEPTACLES. 3. CONCRETE BLOCK WALLS: 40 INCHES ABOVE FINISHED FLOOR (DIMENSION MAY BE ADJUSTED SLIGHTLY, AS REQUIRED TO COMPENSATE FOR VARIABLE JOINT DIMENSIONS, SUCH THAT BOTTOM OF BOXES ARE AT BLOCK JOINTS). 4. WALLS WITH WAINSCOTING: 6 INCHES MINIMUM ABOVE WAINSCOTING, BUT NOT EXCEEDING 48 INCHES ABOVE FINISHED FLOOR. MULTI - OUTLET ASSEMBLIES: 1. OTHER MOUNTING HEIGHT AS REQUIRED /DESIRED. TELEPHONE /DATA OUTLET BOXES: 1. GENERAL: MATCH MOUNTING HEIGHT OF ADJACENT WIRING DEVICE LISTED ABOVE. 2. WALL - MOUNTED TELEPHONE: 40 INCHES ABOVE FINISHED FLOOR. 3. FOR OTHER THAN WIRING DEVICES, REFER TO PARAGRAPHS, ARTICLES. SECTIONS, DIVISIONS, OR DRAWINGS TO OBTAIN MOUNTING HEIGHTS FOR SPECIFIC EQUIPMENT OR SYS I EMS. 16B 1 -10 WIRING DEVICES THE CATALOG NUMBERS LISTED FOR WIRING DEVICES ARE GENERALLY FOR 20A RATED DEVICES. WHERE 15A RATED DEVICES ARE INDICATED ON THE DRAWINGS OR REQUIRED FOR CIRCUIT RATING LIMITATIONS, PROVIDE WIRING DEVICES EQUIVALENT TO THOSE SPECIFIED FOR 20A, BUT RATED FOR 15A. PROVIDE THE FOLLOWING WIRING DEVICES WHERE SHOWN ON DRAWINGS OR REQUIRED. MINOR CHANGES RELATIVE TO THE LOCATION OF ELECTRICAL EQUIPMENT MAY BE MADE TO COMPLY WITH STRUCTURAL AND BUILDING REQUIREMENTS AS DETERMINED IN THE COURSE OF CONSTRUCTION. PROVIDE ALL WIRING DEVICES OF THE SAME MANUFACTURER AND NOT MIXED ON THE PROJECT, TO THE MAXIMUM EXTENT POSSIBLE. PROVIDE COLOR OF TOGGLES AND RECEPTACLES AS REQUESTED BY THE ENGINEER: REFER TO DETAIL SHOWING RECEPTACLES TABLE. 168 1 -11 SWITCH AND OUTLET COVER PLATES SWITCH AND OUTLET PLATES: COLORED, SMOOTH NYLON; BY THE SAME MANUFACTURER AS THE WIRING DEVICES, WHEREVER POSSIBLE. VERIFY DESIRED MATERIALS AND COLORS WITH ENGINEER BEFORE INSTALLATION. SWITCH PLATES IN UNFINISHED ROOMS AND SPACES: STAMPED STEEL, CADMIUM PLATED. INSTALL GROUPS OF SWITCHES UNDER ONE GANGED - PLATE, USUALLY HORIZONTALLY; OR, WHERE REQUIRED BY DETAILS, VERTICALLY. SET ALL COVER PLATES PLUMB, PARALLEL, AND FINISHED FLUSH WITH THE WALL. 16B 2 ELECTRICAL SERVICE AND GROUNDING 16B 2 -1 ELECTRICAL SERVICE SEE DRAWINGS FOR TYPE. SIZE, VOLTAGE, PHASE, AND OTHER REQUIREMENTS. LANDLORD SHALL PROVIDE, OR ARRANGE WITH THE SERVING UTILITY FOR INSTALLATION TO PROVIDE, A RECORDING VOLTMETER AT THE SERVICE POINT, ON THE FIRST DAY THE FACILITY IS OPEN FOR BUSINESS, FOR A 24 -HOUR VOLTAGE TEST. IF VOLTAGE AND REGULATION ARE NOT WITHIN ACCEPTABLE OMITS, ARRANGE WITH THE UTILITY FOR PROPER VOLTAGE. SUBMIT TO THE OWNER A REPORT OF MAXIMUM AND MINIMUM VOLTAGE AND A COPY OF THE RECORDING VOLTMETER CHART. 16B 2 -2 CONNECTION TO SERVING UTILITIES PROVIDE RACEWAYS. TERMINATIONS. METERING PROVISIONS, AND MISCELLANEOUS EQUIPMENT. AS REQUIRED, FOR ELECTRICAL AND TELEPHONE SERVICES FOR CONNECTION BY THE SERVING UTIUTY, IN STRICT COMPLIANCE WITH THE REQUIREMENTS OF ALL APPUCABLE CODES AND OF THE SERVING UTILITY INVOLVED. VERIFY ALL SERVICE TERMINATIONS AND CONNECTION POINTS IN THE FIELD AND WORK IN CONJUNCTION WITH THE UTILITY INVOLVED IN THE INSTALLATION OF ALL SERVICES. PROVIDE ALL MATERIALS AND EQUIPMENT REQUIRED FOR COMPLETE UTILITY CONNECTION BUT NOT FURNISHED BY THE SERVING UTIUTY. NOTIFY THE UTILITY COMPANIES INVOLVED WITHIN TWO WEEKS AFTER NOTICE TO PROCEED, OF ALL REQUIRED INFORMATION NECESSARY FOR THE UTIUTY TO SUPPLY THE PROJECT WITHOUT DELAY. PAY ALL CHARGES OF THE SERVING UTILITY FOR THE ELECTRICAL SERVICE(S). 166 2 -3 GROUNDING PERMANENTLY AND EFFECTIVELY GROUND AND BOND THE ELECTRICAL INSTALLATION IN A THOROUGH AND EFFICIENT MANNER, AND IN CONFORMANCE, AT A MINIMUM, WITH NFPA 70, OR THESE DOCUMENTS, WHERE THEY EXCEED CODE REQUIREMENTS. USE BARE OR INSULATED CONDUCTORS. AS SPECIFIED HEREIN, AND OTHER MATERIALS INDICATED ON THE DRAWINGS. 16B 3 DISTRIBUTION AND CONTROL EQUIPMENT 163 3 -1 LIGHTING AND APPLIANCE PANELBOARDS PANELBOARDS: SQUARE ❑ TYPE NQOD OR NF, AS APPLICABLE, BASED ON VOLTAGE AND AMPERE RATINGS AND REQUIRED SHORT- CIRCUIT INTERRUPTING RATINGS AS SCHEDULED ON THE DRAWINGS, OR APPROVED EQUAL BY SIEMENS, CUTLER HAMMER, OR GENERAL ELECTRIC; COMPLETE WITH BOLT -ON THERMAL MAGNETIC, MOLDED CASE CIRCUIT BREAKERS ASSEMBLED IN A DEAD -FRONT FINISHED CABINET CONTAINING A TYPEWRITTEN CARD DIRECTORY INDICATING EXACTLY WHAT EACH CIRCUIT BREAKER CONTROLS; FULLY - OR SERIES -RATED AND WITH THE INTEGRATED SHORT CIRCUIT CURRENT RATINGS INDICATED ON THE DRAWINGS. PLUG -IN TYPE BREAKERS WILL NOT BE ACCEPTABLE. ALL TWO AND THREE POLE BREAKERS: COMMON TRIP TYPE. BREAKERS USED AS SWITCHES FOR 120V OR 277V LIGHTING CIRCUITS: APPROVED FOR THE PURPOSE AND MARKED "SWD ". BREAKERS USED FOR THE PROTECTION OF HVAC AND REFRIGERATION EQUIPMENT: HACR TYPE. 168 3 -4 DISCONNECT (SAFETY) SWITCHES DISCONNECT (SAFETY) SWITCHES: SQUARE 0, SIEMENS, CUTLER HAMMER, OR GENERAL ELECTRIC FUSED OR NON -FUSED (A5 INDICATED ON DRAWINGS OR REQUIRED) NEMA KS1, HEAVY DUTY, EXTERNALLY OPERATED, VISIBLE -BLADE SAFETY SWITCHES; NEMA ENCLOSURE TYPE INDICATED ON THE DRAWINGS OR SUITABLE FOR THE ENVIRONMENT IN WHICH INSTALLED BASED ON FUSIBLE SWITCH AND FUSE SIZES INDICATED, INCLUDE CLASS R, J, OR L FUSE PROVISIONS AS APPLICABLE. WHERE INDICATED, PROVIDE FUSIBLE SWITCHES PERMANENTLY LABELED AS SUITABLE FOR USE AS SERVICE ENTRANCE EQUIPMENT, WITH INTEGRAL AND SEPARATE NEUTRAL AND GROUND ASSEMBLIES, SUITABLE FOR THE SIZES OF CONDUCTORS INDICATED. DO NOT DOUBLE -LUG ANY TERMINATIONS NOT SPECIFICALLY LISTED AS SUITABLE FOR MORE THAN ONE CONDUCTOR. PROVIDE SWITCHES WHERE NOT FURNISHED WITH THE STARTING EQUIPMENT, AT ALL OTHER POINTS REQUIRED BY NFPA 70, AND WHERE INDICATED ON THE DRAWINGS. 16B 3 -5 FUSES PROVIDE EACH CIRCUIT AND SET OF FUSE CLIPS THROUGHOUT THE WORK WITH BUSSMANN, FERRAZ SHAWMUT, OR LITTLEFUSE FUSES, SIZES AND TYPES AS REQUIRED OR INDICATED. ALL FUSES LARGER THAN 600A: UL CLASS L, SIMILAR TO TYPE KRP -C BUSSMANN LOW PEAK OR EQUAL. FUSES USED TO PROTECT MOTORS: UL CLASS RK5, BUSSMANN FUSETRON OR EQUAL. FUSES USED TO PROTECT ALL OTHER ELECTRICAL EQUIPMENT: UL CLASS RK1, DUAL ELEMENT, BUSSMANN LPS /LPN OR EQUAL. ALL FUSED DEVICES SHALL BE LABELED AS TO TYPE AND SIZE OF FUSE REQUIRED. FURNISH THREE SPARE FUSES OF EACH SIZE AND TYPE USED ON THE PROJECT (EXCEPT FOR MAIN SWITCH FUSES, FURNISH ONE SPARE), NEATLY CONTAINED IN A PROPERLY LABELED CABINET. 16B 4 LIGHT FIXTURES. LAMPS AND BALLASTS 16B 4 -1 LIGHT FIXTURE LOCATIONS UGHT FIXTURES SHOWN ON THE ELECTRICAL DRAWINGS REPRESENT GENERAL ARRANGEMENTS ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR MORE EXACT LOCATIONS. COORDINATE LOCATION WITH ALL OTHER TRADES BEFORE INSTALLATION TO AVOID CONFUCTS. COORDINATE LIGHT FIXTURE LOCATIONS IN MECHANICAL ROOMS WITH FINAL INSTALLED PIPING AND DUCTWORK LAYOUTS. 168 4 -2 LIGHT FIXTURES PROVIDE LIGHT FIXTURES AS SCHEDULED ON DRAWINGS, INCLUDING ALL LAMPS, ALL NECESSARY ACCESSORIES, MATERIAL AND LABOR TO SECURELY HANG, CLEAN, AND MAKE LIGHT FIXTURES COMPLETELY READY FOR USE. UGHT FIXTURE MODEL NUMBERS SCHEDULED ON THE DRAWINGS SHOW ONLY THE MANUFACTURER, GRADE AND STYLE OF LIGHT FIXTURES REQUIRED. PROVIDE: ALL HANGERS, SUPPORTS, AND MISCELLANEOUS HARDWARE REQUIRED TO INSTALL UGHT FIXTURES; PROPER TRIM TO FTT EACH CEILING CONDITION ACTUALLY ENCOUNTERED; ADDITIONAL TIE WIRES CONNECTED TO STRUCTURE TO CONFORM TO SEISMIC REQUIREMENTS WHERE REQUIRED BY THE APPLICABLE BUILDING CODE. PACKAGING OF LIGHT FIXTURES WILL NOT BE ALLOWED. ONLY THOSE LUMINARIES USTED IN THE UGHT FIXTURE SCHEDULE, OR APPROVED IN ACCORDANCE WITH SUBSTITUTIONS OF THESE SPECIFICATIONS, WILL BE ACCEPTED. WHERE THE LIGHT FIXTURE SCHEDULE INDICATES AN ALLOWANCE FOR A SPECIFIC LIGHT FIXTURE, THE PRICE IS A CONTRACTOR PRICE. INCLUDE ALL ADDITIONAL COSTS FOR FREIGHT, LAMPS, AND INSTALLATION OF UGHT FIXTURE AND LAMPS. SURFACE -MOUNT ALL FLUORESCENT LIGHT FIXTURES LOCATED IN AREAS WITHOUT SUSPENDED CEIUNGS UNLESS OTHERWISE INDICATED ON THE DRAWINGS. PROVIDE RIGID METAL SPACERS FINISHED IN WHITE ENAMEL BETWEEN THE TOP OF EACH LIGHT FIXTURE AND THE CEILING ABOVE TO MAINTAIN A 1--1/2 -INCH SPACE. SPACERS SHALL BE APPROVED BEFORE INSTALLATION. INSTAU_ FLUORESCENT LIGHT FIXTURES HUNG IN CONTINUOUS ROWS ON CHANNEL STRUTS SPECIFICALLY DESIGNED FOR THIS PURPOSE. INSTALL ALL FLUORESCENT LIGHT FIXTURES LOCATED IN AREAS WITHOUT CEILINGS IMMEDIATELY BELOW THE ROOF- FRAMING MEMBERS, OR SUSPENDED FROM CHAIN HANGERS SUITABLE IN LENGTH TO PROVIDE THE INDICATED MOUNTING HEIGHT. HANGERS: "HYDEE" HANGER TYPE FOR OUTLET BOX MOUNTING, COMPLETE WITH GROUNDING RECEPTACLE. PLUG, 3 -WIRE CORD AND NECESSARY CHAIN. THROUGH WIRING OF RECESSED LIGHT FIXTURES, IN SUSPENDED CEILINGS, IS NOT PERMITTED. CONNECT EACH LIGHT FIXTURE BY A WHIP TO A JUNCTION BOX. THE WHIP SHALL BE OF SUFFICIENT LENGTH TO ALLOW THE UGHT FIXTURE TO BE RELOCATED WITHIN A 6 -FOOT RADIUS. 166 4 -3 LAMPS PROVIDE LAMPS PER LIGHT FIXTURE SCHEDULE. 166 4 -4 BALLASTS PROVIDE BALLASTS PER LIGHT FIXTURE SCHEDULE. 16B 5 MISCELLANEOUS ELECTRICAL 16B 5 -1 WIRING OF MECHANICAL EQUIPMENT PROVIDE ALL RACEWAYS AND POWER WIRING FOR ALL DIVISION 15 EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS, INCLUDING. BUT NOT UMITED TO, PUMPS, WATER HEATERS, AND HVAC EQUIPMENT. AND ALL LINE- VOLTAGE CONTROL AND INTERLOCK WIRING NOT PROVIDED UNDER DIVISION 15. CONNECT PER MANUFACTURERS' WIRING DIAGRAMS. COORDINATE WITH DIVISION 15 FOR DISCONNECTS FURNISHED WITH EQUIPMENT, AND PROVIDE ALL DISCONNECT SWITCHES AS REQUIRED. AFTER INSTAWNG WIRING, VERIFY THAT EACH MOTOR LOAD HAS THE CORRECT PHASE ROTATION. VERIFY THE ACTUAL "MAXIMUM OVERCURRENT PROTECTION" (MOCP) DEVICE RATINGS AND "MINIMUM CIRCUIT AMPACITY" (MCA) CONDUCTOR SIZING FOR MECHANICAL EQUIPMENT FROM THE EQUIPMENT NAMEPLATE. BASE ELECTRICAL INSTALLATIONS ON ACTUAL REQUIRED AMPERAGES, WHICH MAY VARY SOMEWHAT FROM THE CONDUCTOR AND EQUIPMENT SIZES SHOWN ON THE DRAWINGS; HOWEVER. IN NO CASE, REDUCE THE SIZE OF CONDUCTORS INDICATED ON THE DRAWINGS WITHOUT AUTHORIZATION FROM THE ENGINEER. PROVIDE PROPERLY SIZED ELECTRICAL WIRING AND EQUIPMENT WITHOUT EXTRA COST TO THE OWNER. NOTIFY THE ENGINEER OF ALL CHANGES REQUIRED IN THE ELECTRICAL INSTALLATION DUE TO EQUIPMENT VARIANCES 50 THAT THE EFFECTS ON FEEDERS, BRANCH CIRCUITS, PANELBOARDS, FUSES AND CIRCUIT BREAKERS CAN BE CHECKED PRIOR TO PURCHASING AND INSTALLATION. BE RESPONSIBLE FOR COORDINATING WITH DIVISION 15 TO VERIFY THE ACTUAL AMPACITIES AND CORRECT SIZES OF ALL CONDUCTORS AND OVERCURRENT PROTECTIVE DEVICES FOR ALL EQUIPMENT, AND CORRECT OVERLOAD HEATERS FOR ALL MOTORS, WHEN STARTERS ARE PROVIDED UNDER DIVISION 16. 16B 5 -2 WIRING OF THERMOSTATS, TIME AND TEMPERATURE CONTROLS PROVIDE ALL RACEWAYS, POWER WIRING, AND LINE- VOLTAGE CONTROL AND INTERLOCK WIRING NOT PROVIDED UNDER DIVISION 15, FOR ALL THERMOSTATS. TEMPERATURE CONTROL DEVICES, AND CONTROLS, INCLUDING, BUT NOT LIMITED TO, NIGHT - STATS, WATER HEATER INTERLOCKS, TIME SWITCHES AND OVERRIDE TIMERS. SEE MECHANICAL DRAWINGS FOR LOCATIONS AND TEMPERATURE CONTROL DIAGRAMS. LOW- VOLTAGE CONDUCTORS FOR THERMOSTATS AND TEMPERATURE CONTROL SYSTEM MAY BE RUN EXPOSED ABOVE FINISHED ACCESSIBLE CEILINGS, IF APPROVED AND LISTED FOR THIS PURPOSE, BUT SHALL BE INSTALLED IN CONDUIT WITHIN WALLS AND WHERE EXPOSED IN THE WORK AREAS. 16B 5 -3 TELEPHONE SYSItM PROVISIONS PROVIDE INCOMING TELEPHONE SERVICE RACEWAYS AS INDICATED ON DRAWINGS OR AS REQUIRED BY THE SERVING TELEPHONE COMPANY. PROVIDE 3/4 -INCH THICK PLYWOOD BOARD, FIRE- RETARDANT - TREATED AND STAMPED FRT, SECURELY ANCHORED TO THE WALL, AT THE LOCATION AND OF THE SIZE AS INDICATED ON THE DRAWINGS. PROVIDE FLUSH MOUNTED TELEPHONE OUTLET BOXES WITH 1 -INCH EMT STUB -UP CONCEALED TO ACCESSIBLE CEILING SPACE AT LOCATIONS AS INDICATED ON THE DRAWINGS. 16B 5 -4 DATA SYSTEM PROVISIONS PROVIDE FLUSH MOUNTED DATA OUTLET BOXES WITH 1 -INCH CONDUIT STUB -UP CONCEALED TO ACCESSIBLE CEILING SPACE AT LOCATIONS AS INDICATED ON THE DRAWINGS. 16B 5 -5 TIME SWITCHES TIME SWITCHES: TYPE INDICATED, WITH MANUAL BYPASS SWITCH. NEMA ENCLOSURE SUITABLE FOR THE ENVIRONMENT INSTALLED; NUMBER AND TYPES OF CONTACTS, SEQUENCE, AND VOLTAGE AS INDICATED ON THE DRAWINGS, OR AS REQUIRED, BASED ON THE TIME SWITCH FUNCTION AND THE NUMBER OF BRANCH CIRCUITS OR CONTACTORS CONTROLLED. PROVIDE WIRING TO PHOTOCELLS, CONTACTORS, RELAYS OR OTHER CONTROL POINTS AS REQUIRED. MANUFACTURERS: INTERMATIC, PARAGON OR TORK. TYPE: 1. ELECTRONIC DIGITAL 16B 5 -6 PHOTO CONTROL THE PHOTO CONTROL SHALL: 1. PROVIDE AUTOMATIC SWITCHING FOR LIGHTING LOADS USING A THERMAL DESIGN WITH BUILT -IN DELAY TO ENSURE THAT THE CONTROLLED LIGHTING DOES NOT SWITCH OFF DUE TO AMBIENT LIGHT OR UGHTNING STRIKING THE PHOTOCELL 2. HAVE A RATING BASED ON UL TESTING AT 50% POWER FACTOR FOR BALLAST LOADS, BE UL HSTED, AND MEET ALL APPUCABLE AGENCY REQUIREMENTS 3. BE STEM - MOUNTING TYPE WITH ALL NECESSARY MOUNTING HARDWARE AND INSTRUCTIONS; HAVE A HOUSING CONSTRUCTED OF HIGH IMPACT POLYCARBONATE; PHOTO CONTROL COMPONENTS CONSISTING OF A METAL FILM RESISTOR, DUAL TEMPERATURE COMPENSATING BI -METAL BLADES, SNAP ACTION CONTACT BLADES, CHEMICALLY TREATED /POLYMER ENCAPSULATED CADMIUM SULFIDE PHOTOCELL AND SILVER ALLOY CONTACTS TO ENSURE RELIABLE 5 YEAR MANUFACTURER WARRANTED OPERATION. PHOTO CONTROL SHALL BE 100% FACTORY TESTED FOR FUNCTION WITHIN MANUFACTURER'S SPECIFIED LIGHT LEVELS. 4. BE FROM THE SAME MANUFACTURER OF AND TOTALLY COMPATIBLE WITH THE TIME SWITCHES SPECIFIED ABOVE. 16B 5 -7 LIGHTING CONTACTORS LIGHTING CONTACTORS: 1. INDUSTRIAL DUTY TYPE; SILVER ALLOY, DOUBLE BREAK CONTACTS, CONVERTIBLE WITH NO AND NC INDICATORS; CAPABLE OF ADDING POLES IN THE FIELD; NUMBER AND RATING OF POLES AS INDICATED ON THE DRAWINGS OR REQUIRED BY THE LOAD CONTROLLED; TYPED DIRECTORY AFFIXED TO THE INSIDE OF THE ENCLOSURE DOOR LISTING ALL BRANCH CIRCUITS SWITCHED AND THE CONTROL POWER BRANCH CIRCUIT. 2. SHORT CIRCUIT CURRENT RATING: A. 22.000A AT 240V MAXIMUM 3. ENCLOSURES: A. NEMA 1 4. COIL VOLTAGE: A E TYPE: 1. CONTROL INTERFACE: TWO -WIRE 2. MANUFACTURERS: A. SQUARE D CLASS 8903 L B. CUTLER HAMMER EQUIVALENT C. GENERAL ELECTRIC EQUIVALENT D. SIEMENS EQUIVALENT E. ASCO EQUIVALENT 16B 5 -8 MISCELLANEOUS EQUIPMENT AND CONNECTIONS ALL WIRING AND CONNECTIONS TO ILLUMINATED CASES. ALL WIRING AND CONNECTIONS TO EQUIPMENT FURNISHED BY OTHERS, INCLUDING, BUT NOT LIMITED TO P.O.S. STATIONS., ETC. ALL RACEWAYS. AND ALL WIRING AND CONNECTIONS OF DEVICES TO ENERGY MANAGEMENT SYSTEM THAT ARE NOT THE RESPONSIBILITY OF DIVISION 15. ALL WIRING AND CONNECTIONS OF EXIT DOOR ALARMS. 16B 5 -9 EXISTING FIRE ALARM SYSTEM MODIFICATIONS PROVIDE THE FOLLOWING NEW EQUIPMENT, COMPATIBLE WITH, OR OF THE SAME MANUFACTURER AS, THE EXISTING FIRE ALARM CONTROL PANEL AND SYSTEM, AT LOCATIONS INDICATED ON THE DRAWINGS, AS REQUIRED BY BUILDING CODES, THE LANDLORD, OR ALL THREE, AND CONNECT TO THE EXISTING FIRE ALARM CONTROL PANEL: 1. ADDITIONAL INITIATING DEVICES, INDICATING APPLIANCES, AND INTERCONNECTING CIRCUITS. 2. ADDITIONAL ZONE MODULES REQUIRED BY NEW ZONING. 3. NEW AMPUFIERS AND OTHER EQUIPMENT THAT MAY BE REQUIRED TO INCORPORATE THE NEW INITIATING DEVICES AND INDICATING APPLIANCES INTO THE EXISTING SYSTEM. 4. A NEW ZONE MAP, INCLUDING ALL EXISTING ZONES AND ALL NEW ZONES. FRAMED, MOUNTED UNDER GLASS, AND INSTALLED ADJACENT TO THE FIRE ALARM CONTROL PANEL HORN /SIHOBES SHALL MEET ALL REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT. R O D GC{ 1 5 201 FL_.r0i I CLIN tR