Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL07-593 - MAACO
MAACO 355 TREK DR ELO7-593 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: D J ELECTRIC & CONSTRUCTION Address: P 0 BOX 266 , HOBART WA Contractor License No: DJELECIO27L9 DESCRIPTION OF WORK: TENANT IMPROVEMENT: 200 AMP SERVICE AND WIRE EQUIPMENT Value of Electrical: $30,870.00 Type of Fire Protection: Electrical Service provided by: Permit Center Authorized Signature. I hereby certify that I have read and governing this work will be comp The granting of this pe - 't d construction or the p Signature: Print Name: doc: EL -4/07 0223400042 355 TRECK DR TUKW Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us MAACO 355 TRECK DR , TUKWILA WA JENKINS PROPERTIES INC PO BOX 53290 , BELLEVUE WA DOUG JARVIS PO BOX 266 , HOBART WA PUGET SOUND ENERGY ELECTRICAL PERMIT EL07 -593 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 396 -2856 Phone: Expiration Date: 06/29/2008 ELO7 -593 10/29/2007 04/26/2008 Fees Collected: $738.00 National Electrical Code Edition: 2005 ed this permit and know the same to be true and correct. All provisions of law and ordinances d , whether specified herein or not. to give authority to violate or cancel the provisions of any other state or local laws regulating orized to sign and obtain this electrical permit. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 10 -29 -2007 Parcel No.: 0223400042 Address: Suite No: Tenant: MARCO 1: ** *ELECTRICAL * ** 355 TRECK DR TUKW City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: ELO7 -593 ISSUED 10/18/2007 10/29/2007 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not • resume to give authority to violate or cancel the provision of any other work or local laws regulating construction or th •erformanc- •f work. Signature: Print Name: doc: Cond -Elec / /,6 /Z-- Date: —2 5 EL07 -593 Printed: 10 -29 -2007 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwita.wa.us Tenant Name: ,1,9C 7 Property Owners Name: Mailing Address: ❑ Low Voltage ❑ Generator Property Served by: Puget Sound Energy ❑ Seattle City Light ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION 1 King Co Assessor's Tax No.: 02 - j.- Site Address: 3 5 Suite Number: Floor: E -Mail Address: Valuation of Project (contractor's bid price): $ .30 87'€ s6LD Scope of Work (please provide detailed information): ! r� v/ /e6" e Q't < �Lr HAApplications\Fonns- Applications On Line\4 -2007 - Electrical] Permit Appliation.doc bb City City New Tenant: [...Yes ❑ ..No State CONTACT PERSON Who do we contact when your permit is ready y to be issue Name: Day Telephone: Mailing Address: State Zip Zip Fax Number: ELECTRICAL CONTRACTOR INFORMATION` Company Name: � J - I. Cam. `T/tv Mailing Address: f .0 0642 w 9e6 _ th City Zip Contact Person: , �) l Day Telephone: 2 '6" 324:. �.s" E -Mail Address: Fax Number: 4 /2S , y3 Z Z S 13 Contractor Registration Number: 0 7 Expiration Date: 2_PO4-4.16 Sc?IWfCL Will service be altered? k_ Yes ❑ No Type of Use: P4-7/1 T 3 Type of work: ;® --New ❑ Addition ❑ Service Change ❑ Remodel ._Tenant Improvement ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Adding more than 50 amps? (K Yes ❑ No Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR E C �s►' OR: Print Name: t✓ l � 4. � L ��� S C olo ,lac zle� Signature: Mailing Address: I Date Application Accepted: toM H: ■Applications\Forms- Applications On Line \4-2007 - Electrical Permit Applicat on.doc bh City MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea Date: Day Telephone: '6 3 P6 aeS cv Q RoZs-- State Zip Date Application Expires: ty_i 1 it, /0% Staff Initials: Page 2 of 2 Parcel No.: 0223400042 Address: 355 TRECK DR TUICW Suite No: Applicant: MARCO Receipt No.: R07 -02352 ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Initials: JEM Payment Date: 10/29/2007 12:47 PM User ID: 1165 Balance: 60.00 Payee: D j ELECTRIC & CONSTRUCTION INC. TRANSACTION LIST: Type Method Description Amount Payment Check 2841 590.40 Account Code Current Pmts 000.322.101.00.0 590.40 Total: $590.40 Permit Number: EL07 -593 Status: APPROVED Applied Date: 10/18/2007 Issue Date: Payment Amount: $590.40 0 ; 2 9710 TOTAL doc: Receiot -06 Printed: 10-29 -2007 Parcel No.: 0223400042 Permit Number: EL07 -593 Address: 355 TRECK DR TUKW Status: PENDING Suite No: Applied Date: 10/18/2007 Applicant: MAACO Issue Date: Receipt No.: R07 -02282 Initials: JEM Payment Date: 10/18/2007 10:36 AM User ID: 1165 Balance: $590.40 Payee: D J ELECTRIC & CONSTRUCTION INC. TRANSACTION LIST: Type Method Description Amount Payment Check 2833 147.60 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000.345.832.00.0 147.60 Total: $147.60 Payment Amount: $147.60 4:)96 :10/19 7 TOTAL 147.60 don. Rwnaint -OR Printed. 10 -1R -7007 Project: M G4l Type of Inspection: /l � / ' � //r s: � n Date Called: Special Instructions: Date Wanted: / / �� i Y ,�rn� Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit l�w ?- sss PrIMrr NO. CITY OF TUKWILA BUILDING DIVISION g. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 - F/,¼9 ved per applicable codes. El Corrections required prior to approval. Ins c or: 'Date/ ❑ $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Project: Mil4 co Type of Inspection: dress: 77171: C6e j i-) /4.._ Date Called: Special Instructions: Date Wanted: Requester: Phone No: 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit -5-73 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 JJ Approved per applicable codes. Irrections required prior to approval. COMMENTS: MoVIA F&1 ficieThca GoA /Mimi( r_eurt/rE Inspect r: y I Date: ID $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 1Date: Project: PM 44 _ Type of Inspection: 7t Address: Date Called: Special Instructions: l Date Wanted: Ph 5 a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. ERMIT NO. CITY OF TUKWILA BUILDING DIVISION ,R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: >-PRoi/A6. /'tAfifgNENT tM . < /i «O /N G- A/ c. A/s c d4 » 2s /46- proved per applicable codes. JForrections required prior to approval. 8 Inspector /G1— arc:4691/4P Dat J 2 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: A Type of Inspection: Address: .5 4 wa M Da te Called: ` Special Instructions: Date Wanted: , ! Requester: Phone No: 1 INSPECTION RECORD Retain a copy with permit /z.)7-T,.7 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 70 PERMIT NO. 6MMENTS: 3.9 Q -- iewiA/4/6 rr s/64i Z ,)/ - - f GAG TT /C.1 L gar/7f roved per applicable codes. El Corrections required prior to approval. Inspector: Date: tif/ Air/Me/N(0 I ///.2 th? $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Project: ///9C/0 Type of Inspection: - 7 A re fug M Date Called: Special Instructions: Date Wanted: // /6j p.m. Requester: Phone No: INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: i� OX )rG L c_ov =x f4i, r S?ZA, %F proved per applicable codes. Corrections required prior to approval. Inspec] /Li— /? 4, ix 'Date: AA 2 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: Date: INSPECTION RECORD Retain a copy with permit ACTIVITY NUMBER: EL07 -593 DATE: 10 -18 -07 PROJECT NAME: MAACO SITE ADDRESS: 355 TRECK DR X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: B d ing�Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 .PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete n APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Planning Division ❑ Permit Coordinator TUES/THURS ROUT NG: Please Route Structural Review Required ❑ No further Review Required DATE: DATE: n DUE DATE: 10-22-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 11 -19-07 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Business Owner Information Name Role Effective Date Expiration Date JARVIS, VIRGIL D 01/01/1980 JARVIS, VIRGIL D AGENT 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License Licensee Name Licensee Type UBI Ind. Ins. Account Id Business Type Address 1 Address 2 City County State Zip Phone Status Specialty 1 Specialty 2 Effective Date Expiration Date Suspend Date Separation Date Parent Company Previous License Next License Associated License DJELECIO27L9 D J ELECTRIC & CONST INC ELECTRICAL CONTRACTOR 601872945 CORPORATION PO BOX 266 HOBART KING WA 98025 4254322513 ACTIVE GENERAL UNUSED 6/29/1998 6/29/2008 DJENT * *022BT JARVIVD962O9 Master Electrician Information License Name Status JARVIVD962O9 JARVIS, VIRGIL D ACTIVE I Bond Information 1 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= DJELECIO27L9 10/29/2007 SYMBOL LEGEND RECEPTACLE OUTLETS UGHTING OUTLETS le SINGLE PQ DUPLEX qii DOUBLE DUPLEX SINGLE SPECIAL PURPOSE IIIR DUPLEX OUTLET ON DEDICATED CIRCUIT 0 DOUBLE DUPLEX OUTLET ON DEDICATED CIRCUIT 19 SWITCHED RECEPTACLE ID FLUSH FLOOR OUTLET BOX TV TELEVISION ® TELEPHONE ® TELEPHONE /DATA 0 JUNCTION BOX WITH BLANK COVER IQ TIMER- CONTROLLED RECEPTACLE FOR COFFEE MAKER 0 SURFACE MOUNTED DOWNUGHT © RECESSED DOWNUGHT � PENDANT FIXTURE OR CHANDEUER 0 �-.{ Q WALL MOUNTED FIXTURE CO RECESSED EMERGENCY EGRESS FIXTURE OR NIGHT LIGHT (NL) ( ( SURFACE FLUORESCENT Applicant Name: CASE ENGINEERING I .---- 1 RECESSED FLUORESCENT LOAD DESCRIPTION 1• •I PENDANT FLUORESCENT a FLUORESCENT I OPEN STRIP E = = =7 UNDERCOUNTER FLUORESCENT P"...1.7%//A RECESSED FLUORESCENT CONNECTED TO EMERGENCY CIRCUIT Ka EXIT UGHT (CEIUNG OR UNIVERSAL MOUNT) L•] EXIT UGHT (WALL MOUNT) l � L-► DUAL HEAD EMERGENCY EGRESS FIXTURE 7 V ❑ TRACK LIGHT SWITCH OUTLETS S SINGLE -POLE s2 DOUBLE -POLE s3 THREE -WAY s4 FOUR -WAY SD DIMMER S OCCUPANCY SENSOR Sp PILOT - LIGHTED S KEY - OPERATED SLV LOW VOLTAGE S MASTER CI PUSHBUTTON os CEIUNG MOUNTED OCCUPANCY SENSOR 2 ABBREVIATIONS CKT CIRCUIT C.O. CONDUIT ONLY AL ALUMINUM CU COPPER REC RECEPTACLES LTS LIGHTS GFCI GROUND FAULT CIRCUIT INTERRUPTER (R) REMOVE EXISTING XFMR TRANSFORMER GND GROUND NL NIGHT UGHT PP POWER POLE WP WEATHER PROOF EXTG EXISTING P.O.S. POINT OF SERVICE CLG CEILING TTB TELEPHONE TERMINAL BOARD (E) EXTG. TO REMAIN (RE) RELOCATED EXISTING U.O.N. UNLESS OTHERWISE NOTED PANELBOARDS, SWITCHES & EQUIPMENT CIRCUIT BREAKER PANEL .A SWITCHBOARD OR MOTOR CONTROL CENTER TERMINAL CABINET QJ DISCONNECT SWITCH Q1 FUSED DISCONNECT SWITCH ®.1 COMB. STARTER & DISCONNECT SWITCH FAN CONNECTION ® EQUIPMENT CONNECTION 0 MOTOR CONNECTION 0-- MULTI -- OUTLET PLUG -IN ASSEMBLY (SEE NOTES) ADDITIONAL SYMBOLS 5 CIRCUITING 1.2 WIRING CONCEALED IN CLG. OR WALL - - - WIRING CONCEALED IN FLOOR 1+I- NO. OF CONDUCTORS --a-- BRANCH CIRCUIT HOME RUN �II GROUNDING ELECTRODE -LV- LOW VOLTAGE -e--fl- CIRCUIT WITH ISOLATED GROUND PANEL SCHEDULE NUMBER L1 LOCATION: SHOP SERVING: RECEPTACLES, EQUIPMENT 208Y/120 VOLTS 3 PHASE 4 WIRE 100 C AMP with MAIN BREAKER NQ . LOAD DESCRIPTION KVA Applicant Name: CASE ENGINEERING KVA LOAD DESCRIPTION NO. 1 REC - SHOP EAST WALL 1.2 SPARE SPARE . SPARE SPRAY BOOTH OVEN SUBFEED - PANEL L1 SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 Lt) U) 7 CC ! C l C l CC ! Cl CO T T T CD T TO 0 CD REC - BREAKROOM COFFEE 2 3 REC - SHOP EAST WALL 1.2 PAINTING SHOP 2.30 7769 REC - BREAKROOM MICROWAVE 4 5 REC - SHOP NORTH WALL 1.2 1 45.6 1. CALCULATIONS ARE BASED ON OHMIC METHOD, 277 VOLTS UNE TO GROUND FAULT. 2. CONDUCTOR IMPEDANCE IS BASED ON NATIONAL ELECTRICAL CODE TABLE 9. REC - BREAKROOM REFRIGERATOR 6 7 REC - SHOP CENTER 0.8 Location Fixture Description REC - BREAKROOM 8 9 REC - WEST WALL 1.2 1 5 64.0 960.0 REC - OFFICES 10 11 SPARE 215.0 4 -LAMP INDUSTRIAL STRIP FIXTURE 10 REC - OFFICES 12 13 SPARE 2455.0 PAINT BOOTH AIR RESPIRATOR 14 15 LTS - PAINT BOOTH 0.8 PAINT STORAGE SCALE 16 17 LTS - PAINT BOOTH 0.8 PAINT STORAGE MIXER 18 H 19 SPARE PAINT STORAGE SPARE 20 21 SPARE SPARE 22 23 SPARE SPARE 24 25 SPACE SPACE 26 27 SPACE SPACE 28 29 SPACE SPACE 30 REMARKS: CONNECTED LOAD: 15.9 KVA 44 AMPS DEMAND LOAD: KVA AMPS PANEL SCHEDULE NUMBER H1 LOCATION: SHOP SERVING: LTS, EQUIPMENT 480Y/277 VOLTS 3 PHASE 4 WIRE 200 AMP with MAIN BREAKER N0. LOAD DESCRIPTION KVA Applicant Name: CASE ENGINEERING LL Applicant Address: 10614 BEARDSLEE BLVD, STE C, BOTHE, WA 98011 Applicant Phone: 425- 402.9400 KVA LOAD DESCRIPTION N0. 17.6 12.2 15.9 SPARE SPARE . SPARE SPRAY BOOTH OVEN SUBFEED - PANEL L1 SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 LTS - EXISTING OFFICES SPARE SPARE COMPRESSOR COMPRESSOR SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE 1.2 17.4 17.4 Allowed W /SF Area in ft2 Allowed x Area 125 3/0 CU 1 PAINTING SHOP 2.30 7769 17868.7 200 PAINT STORAGE 0.80 182 1 45.6 1. CALCULATIONS ARE BASED ON OHMIC METHOD, 277 VOLTS UNE TO GROUND FAULT. 2. CONDUCTOR IMPEDANCE IS BASED ON NATIONAL ELECTRICAL CODE TABLE 9. 2. CONTRACTOR SHALL VERIFY AVAILABLE FAULT CURRENT WITH UTILITY. 0.0 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts Proposed Lighting Wattage (Interior) 18014,3 Location Fixture Description # of Fixtures W /Fixt W Proposed H RELOCATED 2-LAMP FLUORESCENT 1 5 64.0 960.0 175W METAL HALIDE 1 215.0 215.0 4 -LAMP INDUSTRIAL STRIP FIXTURE 10 128.0 1280.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 2455.0 REMARKS: CONNECTED LOAD: 81.7 KVA 98 AMPS DEMAND LOAD: KVA AMPS Lighting Summary 2007 Washington State Nonresidential Energy Code CempGa,ce Farms Revised - Jury 2007 Project Info Project Address MAACO Date 8/21/2007 355 TRECK DRIVE For Building Department Use TUKWILLA, WA Applicant Name: CASE ENGINEERING LL Applicant Address: 10614 BEARDSLEE BLVD, STE C, BOTHE, WA 98011 Applicant Phone: 425- 402.9400 CURRENT 1 o ct Description NEW CONSTRUCTION 3/4 Compliance Option LIGHTING POWER ALLOWANCE Maximum Allowed Lighting Wattage (Interior) Location Occupancy Description Allowed W /SF Area in ft2 Allowed x Area 125 3/0 CU 1 PAINTING SHOP 2.30 7769 17868.7 200 PAINT STORAGE 0.80 182 1 45.6 1. CALCULATIONS ARE BASED ON OHMIC METHOD, 277 VOLTS UNE TO GROUND FAULT. 2. CONDUCTOR IMPEDANCE IS BASED ON NATIONAL ELECTRICAL CODE TABLE 9. 2. CONTRACTOR SHALL VERIFY AVAILABLE FAULT CURRENT WITH UTILITY. 0.0 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts Proposed Lighting Wattage (Interior) 18014,3 Location Fixture Description # of Fixtures W /Fixt W Proposed RELOCATED 2-LAMP FLUORESCENT 1 5 64.0 960.0 175W METAL HALIDE 1 215.0 215.0 4 -LAMP INDUSTRIAL STRIP FIXTURE 10 128.0 1280.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 2455.0 SHORT CIRCUIT CALCULATIONS DESCRIPTION CIRCUIT DEFINITION # IN CONDUCTOR OHMS /MFT CIRCUIT IMPEDENCE OHMS AVAILABLE FAULT QTY LENGTH SIZE PARALLEL R X R X Z CURRENT AVAILABLE FAULT CURRENT 1 3/4 3 #8 CU 1 #10 CU @ PSE 500 kVA XFMR 0.00000 0.01057 0.01057 26,200 FEEDER TO PANEL H1 125 3/0 CU 1 0.077 0.042 0.00963 0.00525 0.01096 200 1 0.00963 0.01582 0.01852 14,957 NOTES TO CALCULATIONS: 1. CALCULATIONS ARE BASED ON OHMIC METHOD, 277 VOLTS UNE TO GROUND FAULT. 2. CONDUCTOR IMPEDANCE IS BASED ON NATIONAL ELECTRICAL CODE TABLE 9. 2. CONTRACTOR SHALL VERIFY AVAILABLE FAULT CURRENT WITH UTILITY. FEEDER SCHEDULE CONDUIT CONDUCTORS TAG AMPS QTY SIZE PHASE /NEUTRAL GROUND 50 1 3/4 3 #8 CU 1 #10 CU 50G > 100 1 1 -1/4 4#3 CU 1 #8 CU OONG* 200 1 2 4#3/0 CU 200N > LOAD SUMMARY (PER NEC 220 CATEGORIES) PANEL H DESCRIPTION CONNECTED LOAD -kVA DEMAND FACTOR DEMAND kVA LOAD AMPS UGHTING RECEPTACLES - RECEPTACLES -- MOTORS LARGEST MOTOR HEATING COOLING MISCELLANEOUS TOTAL SPECIFIC USE GENERAL USE ** LOAD 2.8 5.7 8 -6 17.4 17.4 0.0 0.0 29.8 81.7 1.25 1.00 1.00 1.25 1.00 1.00 1.00 *50% DEMAND ON GENERAL USE RECEPTACLES OVER 10 kVA * *DOES NOT INCLUDE RECEPTACLES FOR SPECIFIC EQUIPMENT 3.5 5.7 8.6 17.4 21.8 0.0 0.0 29.8 4 7 10 21 26 0 0 36 86.8 105 ID 480Y/277V 3PH, 4W ELECTRICAL SITE PLAN SCALE: „ 1" = 20'-0" NORTH SEE RISER DIAGRAM FOR SERVICE SIZE. '17\11 APPROXIMATE LOCATION OF EXISTING PSE PAD - MOUNTED TRANSFORMER Plan mew Approval of the *Won of OProved BY Debt, /0 r City orWeft BUILDING DIVISION le ins and emission& does I)! authorize Receipt NO changes shall be made to. the scope of work j �taildi o Division. ap of NOTE: Revisions will require a new plan submittal and may include additional plan review fees. w`C coo p N E G CN A TO EXISTING 15OkVA UTILITY CO. PAD -MTD TRANSFORMER 200N H1 f < 50G RISER DIAGRAM NOT TO SCALE 30 kVA XFMR • #8 CU L1 100NG2> LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION INTERIOR RELOCATED EXISTING 2 -LAMP, 8' INDUSTRIAL STRIP FLUORESCENT FIXTURES MOUNTED AT 16' AFF. F1 175W METAL HALIDE EXPLOSION PROOF FIXTURE MOUNTED AT 10' AFF F2 4 -LAMP, 8' INDUSTRIAL STRIP FLUORESCENT FIXTURE MOUNTED AT 16' AFF LAMP 2 -F32T8 1 -175W MH 4 -F32T8 WATTS /FIXT 64 215 128 APPROVED PL • *:S , ^ „`I7 SPECIFI A9ONS 411 V11.. hn "m 2'° 'ANGED, MODIFIED OR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING orFIc :AL, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND IS , �'-12..'4CT TO FIELD INSPECTIONS. Puhlc Works, Building Division PERMIT NUMBER 07 APIY r v RECEIVED CITY OF Ti Ii1'Vt OLI 1 8 tiii l PEHMI r CENTER Project Title: 355 Treck Drive Tukwila, Washington Sheet Title: Designed By: MSC Drawn By: CJP Project No: 7105 Date: 08/06/07 Sheet Number: F;1 El■°1-G15 FILE COPY D.J. ELECTRIC, INC P.O. BOX 256 HOBART, WA 98025 TEL 206-396-2856 FAX 425-432-2513 CASE ENGINEERING Consulting Electrical Engineers 10614 Beardslee Blvd., Suite C Bothell, Washington 98011 Phone: 425 -402 -9400 Fax: 425- 402 -9402 Tenant Improvements for: MAACO Collision Repair & Auto Painting ELECTRICAL SITE PLAN, RISER DIAGRAM, LEGEND & SCHEDULES PAINT MIXING E STORAGE rrirrrrr.112 rmrrrriiriiir. AVAIIVAIFAIF +48" GFCI 3 +48 GFCI OFFICE BREAKPJ" 1 L1- 2,4,6, 8,10,12 OFFICE OFFICE DRY STORAGE NEW RAMP / / COMPRESSOR COMPRESSOR #6 CU TO SERVICE GROUND L1- 16,18,20 H1- 13,15,17 L1 -1,3 +48" L1 GFCI METER + 48" GFCI L1 -9 PREFAB PAINT BOOT -1 S +48" GFCI 3 J 1 ❑ 1 NEUJ 9 +48" GFCI RAMP +48" GFCI 51 +48" GFCI 7 (VERIFY MOUNTING) GFCI 3 2—HR BUILDING SEPARATION (VERIFY) +48" GFCI +48" GFCI L1 -5,7 5 +48" GFCI +48" GFCC POWER /COMMUNICATIONS FLOOR PLAN ■ ) NORTH SCALE: 1/8" = 1' -0" FLAG NOTES PROVIDE CIRCUIT FOR SPRAY BOOTH /OVEN CONTROL PANEL. VERIFY EXACT LOCATION. FURNISH 30A -3P NON —FUSED DISCONNECT SWITCH (INSTALLED BY OTHERS). J —BOX FOR AIR RESPIRATOR LOCATED ABOVE PAINT BOOTH. VERIFY EXACT LOCATION OF NON —FUSED DISCONNECT WITH COMPRESSOR SUPPLIER PRIOR TO ROUGH —IN. PROVIDE CIRCUITS FOR PAINT SCALE, MIXER & FUTURE. VERIFY J —BOX MOUNTING LOCATION. PROVIDE 48" GROUNDING BAR FOR DRUMS. GROUNDING BAR SHALL BE FIELD LOCATED BY THE MAACO INSTALLER. VERIFY GROUNDING REQUIREMENTS. PROVIDE CIRCUITS FOR EXISTING OFFICE RECEPTACLES. VERIFY REQUIREMENTS. REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC OCT 2 6 2007 City Of Tukwila B ILDIN DUISION RECEIVED CITY OF TOKw►I A oci 1 8 2007 PEHMI1 CENTER �1E D.J. ELECTRIC, INC P.O. BOX 256 HOBART, WA 98025 TEL 206-396-2856 fAX 425-432-2513 NI CA S h; Pr ENGINEERING Consulting Electrical Engineers 10614 Beardslee Blvd., Suite C Bothell, Washington 98011 Phone: 425 -402 -9400 Fax: 425- 402 -9402 Project Title: Tenant Improvements for: MAACO Collision Repair & Auto Painting 355 Treck Drive Tukwila, Washington Sheet Title: ELECTRICAL PLAN L cl 3 Designed By: MSC Drawn By: CJP Project No: 7105 Date: Sheet Number: 08/21/07 E2 GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REF R TO PANEL H1 UNLESS OTHERWISE NOTED. LIGHTING FLOOR PLAN ■ NOi27H SCALE: 1/8" = 1 —o" REVIEWED FOR CODE COMPLIANCE NFPA70 -NEC OC i 2 6 2007 City Of Tukwila EILDINC DIVISION FLAG NOTES MOUNT J —BOX ABOVE BOOTH FOR PAINT BOOTH LIGHTING. LIGHTING BY OTHERS. PROVIDE CIRCUIT FOR EXISTING LIGHTING TO REMAIN. •L(A RECEIVED CITY OF TUKVVII A OCT 1 8 2007 PEHIVIIT CENTER 01E D.J. ELECTRIC, INC. PO Box 256 HOBAR T, WA 98025 TEL 206-396-2856 FAX 425-432-2513 Consulting Electrical Engineers 10614 Beardslee Blvd., Suite C Bothell, Washington 98011 Phone: 425- 402 -9400 Fax: 425- 402 -9402 Project Title: NI CASE ENGINEERING Tenant Improvements for: MARCO Collision Repair & Auto Painting 355 Treck Drive Tukwila, Washington Sheet Title: LIGHTIN G FLOOR PLAN Designed By: MSC Drawn By: CJP Project No: 7105 Date: Sheet Number: 08/21/07 E3