Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL07-668 - DIGITAL FOREST
DIGITAL FOREST 12201 TUKWILA INL BL STE 400 ELO 7-668 Cityf Tukwila Parcel No.: 0923049120 Permit Number: EL07 -668 Address: 12201 TUKWILA INTERNATIONAL BL TUKW Issue Date: 01/08/2008 Suite No: Permit Expires On: 07/06/2008 Tenant: Name: DIGITAL FOREST Address: 12201 TUKWILA INTERNATIONAL BL , TUKWILA WA Owner: Name: INTERNATIONAL GATEWAY WEST Phone: Address: 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA Contact Person: Name: KEVAN ARTHURS Phone: 206 -769 -1676 Address: 5614 7TH AVE S , SEATTLE WA Contractor: Name: VECA ELECTRIC CO INC Phone: 206 860 -0231 Address: 5614 7 AV S , SEATTLE WA Contractor License No: VECAECI542MU Expiration Date: 10/31/2009 DESCRIPTION OF WORK: INSTALL (2) NEW ROOF TOP HVAC UN1TS (175 AMP FEEDERS) Value of Electrical: $18,000.00 Fees Collected: Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: SEATTLE CITY LIGHT doc: EL -4/07 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us • ELECTRICAL PERMIT $471.50 Permit Center Authorized Signature: W Date: 1 e-0 ZJ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this • - ... 't does not pr - sume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or e • e ce of w •i. I am authorized to sign and obtain this electrical permit. !� Signature: t �!� Date: / D — 60 7` Print Name: . /7 y S 17 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. EL07 -668 Printed: 01 -08 -2008 I: ** *ELECTRICAL * ** doc: Cond -Elec City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 0923049120 Permit Number: ELO7 -668 Address: 12201 TUICWILA INTERNATIONAL EL TUICW Status: ISSUED Suite No: Applied Date: 11/08/2007 Tenant: DIGITAL FOREST Issue Date: 01/08/2008 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: / 0 ' EL07 -668 Printed: 01 -08 -2008 CITY OF TUKWIL' Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Site Address: 12201 Tukwila International Blvd. Tenant Name: Digital Forest Property Owners Name: Sabey Construction Mailing Address: 12201 Tukwila International Blvd Name: Wovan Art Mailing Address: 5614 7th Ave South E - Mail Address: kevan.arthurs@veca.com Company Name: VECA Electric Mailing Address: P.O. Box 80467 Contact Person: Kevan Arthurs E -Mail Address: kevan arthurs@veca.com Contractor Registration Number: VECAECI -542 -14U Property Served by: ❑ Puget Sound Energy Seattle City Light H:Wpplications\Fo'ms- Applications On Line \ 4-2007 - Electrical Permit Application.doc bh Electrical Permit No. E ' -- 196 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: oq,30) -1- 1.1)1) Tukwila City Seattle City Suite Number: 400 Floor: 4th New Tenant: ❑ Yes © ..No WA State CONTACT PERSON - Who do we contact when your permit is ready to be issued Day Telephone: 206 - 769 - 1676 Fax Number: 206 - 763 -0505 ELECTRICAL CONTRACTOR INFORMATION Seattle City WA State WA State Day Telephone: 206 769 - 1676 Fax Number: 206 - 763 - 0505 Expiration Date: 10/31/08 98168 Zip 98108 Zip 98108 Zip Valuation of Project (contractor's bid price): $ 18, 000.00 Scope of Work (please provide detailed information): Install (2) new roof top HVAC units ( 175 amp Feeders) Will service be altered? ❑ Yes ® No Adding more than 50 amps? ® Yes ❑ No Type of Use: Type of work: ❑ New © Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Page 1 of 2 Signatur : Print Name: - Laura Mailing Address: 5614 7th Ave South RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) BUILDING 0 i R OR ELECTRICAL I ` CTO H: Wpplications\Fonns- Applications On Line4-2007 - Electrical Permit Application.doc bb Seattle City MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58:00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: 11/06/07 Day Telephone: 206- 436 -5245 WA State 98108 Zip I Date Application Accepted: Il —4_07 I Date Application Expires: 5-49, g Staff Initials: I Page 2 of 2 Parcel No.: 0923049120 Permit Number: EL07 -668 Address: 12201 TUKWILA INTERNATIONAL BL TUB:W Status: PENDING Suite No: Applied Date: 11/08/2007 Applicant: DIGITAL FOREST Issue Date: Receipt No.: R07 -02451 Initials: WER Payment Date: 11/08/2007 10:56 AM User ID: 1655 Balance: $0.00 Payee: VECA ELECTRIC TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Payment Amount: $471.50 Amount Payment Check 1193 471.50 Account Code Current Pmts 000.322.101.00.0 377.20 000.345.832.00.0 94.30 Total: $471.50 doc: Receiot -06 Printed: 11-08 -2007 Project: ibIGnWt ottt,5' -7 Type of Inspection: er/0 Addreisb / 7- 1 7 fiewim z ipecicl Called: Instructions: /9 is .... 102•,10/ Date Wanted: Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 PERMIT NO. (206)431-3670 gomMENTS: 01 -- Fla A.. roved per applicable codes. Corrections required prior to approval. l fil, ra $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: %.nart r� i ( 44. r ti 6 A 123: 122 121 120 M- 118 117- 116 115- 114° 113 112 - 111 110 109: 108 107 106 105 104 103 102 101- 100 99 ; 98 97- 96- 95 94 93 92- 91 90 89- 88 87- 86 - 85- 84= 83- 82 81 80- 79- 78 77 76 75- 74- 73 72- 71 ° 70 . 69 68 67 - 66 65 64 - Location: Digital Forest 11/30/200712:00:00 AM 12/1/2007 611/Mk #er / cod Nt^.e / J G J9 , J 4p 12:00:00 Start: 11/29/2007 9:33:34 AM End: 12/7/2007 11:27:04 AM Digital Forest AM 12/2/2007 12:00:00 AM Chart 12/3/2007 12:00:00 AM 12/4/2007 12:00:00 AM 12/5/2007 RMS Current - IA (A)— RMS Current -IB (A) — RMS Current -IC (A) FILE COPY i INCOMPLETE '.TR # Page 1 of 1 12:00:00 AM 12/6/2004tfff(2007 12:00:00 AM DEC 2 4 2007 PERMIT CENTEh User Id: Steve Yarhrnunh Kevan Arthurs To: Subject: Bill Buterbaugh application ELO7 -668 Bill, Please look at the recorded readings from the main panel in question. You can seethe peaks etc but readings were. Avg current IA- 494.64 IB -485.1 IC — 495.6 Max or peak current IA — 740.7 IB -700.5 IC -736.2 Hopefully this clears up any questions on the connected load but if you have any questions Please give me a call at 206 - 769 -1676 Thanks Kevan Arthurs General Foreman VECA Electric & Communications 5614 7 Ave S I PO Box 80467 I Seattle, WA 98108 I P. 206 - 436 -5200 I C. 206 - 769 -16761 F. 206 -763 -0505 I www.veca.com REVIEWED FOR CODE COMPLIANCE NFPA70 -NEC JAN -2 2008 C ity Of Tukwila B ILDXN D ION 0 13° 1 (18 RECEIVED FILE COPY INCOMPLETE DEC 242007 LT R# . PERMIT CENTEt- November 13, 2007 Kevan Arthurs 5614 7 Ave S Seattle WA 98108 Dear Mr. Arthurs, Bill Rambo Permit Technician Enclosures File: EL07 -668 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director RE: Letter of Incomplete Application # 1 Electrical Permit Application EL07 -668 Digital Forest — 12201 Tukwila International Bl This letter is to inform you that your permit application received at the City of Tukwila Permit Center on November 8, 2007 is determined to be incomplete. Before your application can continue the plan review process the following item from the following department needs to be addressed: Building Department: Bill Buterbaugh, at 206 973 -4758, if you have any questions concerning the following comments. 1. Provide load calculations for SWBD 4DI, show existing and new loads per NEC 220.87 Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that three (3) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted throe** the mail or by a messenzer service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, CeA44/ P:\Permit Center\Incomplete Letters\2007\EL07 -668 Incomplete Ltr #I.DOC wer 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DEPARTMENTS: ending 11A)(/ (ti � ��t Bending Division Complete TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY REVIEW /ROU SLIP ACTIVITY NUMBER: EL07 -668 DATE: 12 -24 -07 PROJECT NAME: DIGITAL FOREST SITE ADDRESS: 12201 TUKWILA INTERNATIONAL BL Original Plan Submittal X Response to Incomplete Letter # 'I Response to Correction Letter # Revision # After Permit Issued DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Structural Review Required Fire Prevention Li Planning Division Public Works ❑ Structural ❑ Permit Coordinator Incomplete DUE DATE: 12-27-07 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01 -24 -08 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: D�E TS: Btt ivision Public Works ❑ Complete PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL07 -668 DATE: 11 -08 -07 PROJECT NAME: DIGITAL FOREST SITE ADDRESS: 12201 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: 1 11 -- ` ?'"O, LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2-28-02 Fire Prevention Structural Incomplete Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: Planning Division ❑ Permit Coordinator DUE DATE: 11 -13 -07 Not Applicable DUE DATE: 12 -11 -07 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: EL07 -668 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Digital Forest Project Address: 12201 Tukwila International B1 Contact Person: Kevan Arthurs Phone Number: 40 b — 70-/‘ 71 Summary of Revision: Sheet Number(s): e f GovG/• "Cloud" or highlight all areas of revision including daterevisio (- 4f ^ ^ Received at the City of Tukwila Permit Center by: Entered in Permits Plus on g \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Steven M. Mullet, Mayor Steve Lancaster, Director RECEIVED CITY OF TUKWILA 'DEC 24 HP E MIT CENTER License Information License VECAECI542MU Licensee Name VECA ELECTRIC CO INC Licensee Type ELECTRICAL CONTRACTOR UBI 601190731 Ind. Ins. Account Id AGENT Business Type CORPORATION Address 1 5614 7TH AVE S Address 2 PO BOX 80467 City SEATTLE County KING State WA Zip 98108 Phone 2064365200 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 7/31/1946 Expiration Date 10/31/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License CONTIK *965D6 Business Owner Information Name Role Effective Date Expiration Date FAIRBANKS, THOMAS 01/01/1980 ALLEN, RON AGENT 01/01/1980 Look Up a Contractor, Electric , n or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Master Electrician Information License Name Status CONTIK *965D6 CONTI, KEITH ACTIVE I Bond Information i https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= VECAECI542MU 01/08/2008 FEEDER SCHEDULE I 8° (q sa /S \1 FEEDER COPPER CONDUCTORS AMPACITY NO. CONDUIT WIRE NOTE 2 A4 1" 4 - #4, 1#8 G. 70 A3 1" 3 -- #4, 1#8 G. 70 B4 1 1 /4" 4 - #2, 1 #6 G. 115 B3 1 1/4" 3 - #2, 1 #6 G. 115 CH 2" 3 - #1, 1111 /0 N, 1#6 G. 120 C4 1 1 /2" 4 - #1, 1 #6 G. 130 C3 1 1/2" 3 - #1, 1 #6 G. 130 D5 2" 5 - #1/0, 1 #6 G. 136 D4 1 1/2" 4 -- #1/0, 1 #6 G. 150 D3 1 1/4" 3- #1/0, 1 #6 G. 150 E5 2" 5 - #2/0, 1 #6 G. 156 E4 2" 4 - #2/0, 1 #6 G. 175 ,-- - .. __.- " 175 2 . _._ 3 ; #2/0, 1` #6 G. - ------F5 2„ 5 - #3/0, 1 #6 G. 180 F4 2" 4 -- #3/O, 1 #6 G. 200 F3 1 1/2" 3 -- #3/0, 1 #6 G. 200 05 2 1/2" 5 - #4/0, 1 #6 G. 208 G4 2" 4 -- #4/0, 1 #4 G. 230 G3 2" 3 - #4/0, 1 # • G. 230 H5 3" 5- 250kcmil, 1 #4 C. 232 H4 2 1/2" 4- 250kcmil, 1 #4 G. 255 H3 2 1/2" 3--- 250kcmil, 1 #4 G. 255 J5 3" 5- 300kcmII, 1 #4 G. 256 J4 3" 4- 300kcmil, 1 #4 G. 285 J3 3" 3- 300kcmil, 1 #4 G. • 285 K5 3" 5- 350kcmil, 1 #4 G. 280 K4 3" 4- 350kcmil, 1 #4 G. 310 K3 3" 3-- 350kcmil, 1 #4 C. 310 L5 3" 5- 400kcmil, 1 #2 G. 304 L4 3" 4- 400kcmil, 1 #2 G. 335 L3 3" 3-400kcmil, 1 #2 G. 335 M5 3 1/2" 5- 500kcmil, 1 #2 G. 344 M4 3" 4- 500kcmil, 1 #2 G. 380 M3 3" 3- 500kcmil, 1 #2 G. 380 N5 4" 5- 600kcmil, 1 #2 G. 380 N4 3 1/2" 4- 600kcmil, 1 #2 G. 420 N3 3 1/2" 3- 600kcmil, 1 #2 G. 420 2H5 (2) 3" 5- 250kcmil, 1 #2 G. EA. 464 2H4 (2) 2-1/2" 4- 250kcmil, 1 #2 G. EA. 510 2H3 (2) 2 -1/2" 3- 250kcmil, 1 #2 G. EA. 510 2J5 (2) 3" 5- 300kcmil, 1 #2 G. EA. 512 2K5 (2) 3" 5--- 350kcmil, 1 #1 G. EA. 560 2K4 (2) 3" 4- 350kcmil, 1 #1 G. EA. 620 2K3 (2) 2-1/2" 3- 350kcmil, 1 #1 G. EA. 620 2M4 (2) 3" 4- 500kcmil, 1 #1/0 G. EA. 760 2M3 (2) 3 3- 500kcmil, 1 #1/0 G. EA. 760 2N4 (2) 3 -1/2" 4- 600kcmil, 1 #1/0 G. EA. 840 2N3 (2) 3 -1/2" 3--- 600kcmil, 1 #1/0 G. EA. 840 3L4 (3) 3" 4- -400kcmil, 1 #2/0 G. EA. 1005 3L3 (3) 3" 3- 400kcmil, 1 #2/0 G. EA. 1005 4H4 (4) 2 -1/2" 4- 250kcmil, 1 #2/0 G. EA. 1020 4H3 (4) 2 -1/2" 3- 250kcmil, 1 #2/0 G. EA. 1020 4-K4 (4) 3" 4- 350kcmil, 1 #3/0 G. EA. 1240 4-K3 (4) 3" 3- 350kcmil, 1 #3/0 G. EA. 1240 4N4 (4) 3 -1/2" 4-600kcmil, 1 #4/0 G. EA. 1680 4N3 (4) 3 -1/2" 3- 600kcmil, 1 #4/0 G. EA. 1680 5N4 (5) 3 -1/2" 4- 600kcmil, 1 #250 G. EA. 2100 5N3 (5) 3 -1/2" 3- 600kcmil, 1 #250 G. EA. 2100 6M4 (6) 3" 6- 500kcmil, 1 #250 G. EA. 2280 6N4 (6) 3 -1/2" 4- 600kcmil, 1 #350 G. EA. 2520 6N3 (6) 3-1/2" 3- 600kcmil, 1 #350 G. EA. 2520 ROOF 4TH FLOOR LEVEL P -2 r 5N 4 2000A -4P 65KAIC TVSS REMOTE GENERATOR ANNUNCIATOR (IN UPS ROOM) DIGITAL METERING l ¢ 1 CD CO CD METERING COMPARTMENT PER SEATTLE CITY LIGHT REQUIREMENTS 5N 4 BYPASS/ ISOLATION SWITCH Nod & i J AC -1 Y' AC -2 AC -3 ` AC- 4 [f►1V T/IT d I F l H3 TO SCL F LIGHTNING ARRESTER r L ._ 3 G 7 1250KW/1563KVA ENGINE /GENERATOR 180KW ■nr- UPS (TYP) 180KW UPS (TYP) 5N4 8 2M 4 (2 N3 N3 LL I- Q¢ 00 00 UPS 1 9 UPS 2 SWBD 401 - DIGITAL FOREST 480Y/277V, 30, 4W, 65KAIC, 2000A SWBD MSB -2 - DIGITAL FOREST & BLDG COMMON LOADS 480V/277V, 30, 4W, 65KAIC, 2500A 12 MINUTE BATTERIES (TYP) 10 M4 12 MINUTE BATTERIES (TYP) 11 DC POWER (¢¢ 12 DIGITAL METERING DP2 - BLDG COMMON LOADS 800A 480V/277V,_30, 4W 65KAIC AI 2M 4 1 SYSTEM CONTROL CABINET DC POWER FUTURE 2M4 w I ¢ Q 0 0 EXTERNAL MAINTENANCE BYPASS H4 SOUTH CLOSET 125A MLO 00 0 00 15 r r C4 r p U4 800A TVSS 750KW LOAD BANK 2000A BUSWAY r 16 H3 00 00 C3 SWBD, G -1 - DIGITAL FOREST 480V/277V, 30, 4W, 65KAIC, 2000A STANDBY POWER RISER DIAGRAM SCALE: NONE PDU -1 75K VA C3 PDU -2 75K VA C3 , PDU -3 75KVA a a 4 4 a T -1 30 KVA 480V 208Y/120V 30 4W 63 B4 B4 w eE a l u-r ¢¢ (° to to NN 17 18 19 20 21 J MLO I G4 225A 75 KVA 480V 208Y/120V 30 4W II C3 ,'~ PDU -4 75KVA C2P4 100A MLO LP 225A MCB T � C3 , [PDU -5 75KVA H4A NORTH CLOSET 125A 4P2 MLO 225A MCB C3 PDU -6 75KVA C3 , PDU ---7 75KVA T- 2 30 KVA 480V 208Y/120V 30 4W B3 B4 - - • �.;,:r, -;c No r, Or?";s fi 'II ' rn of ,,,,fork prIor , NOTE: Revisions win requirr 9nd may Include aoditio jai T- 2 30 KVA 480V 208Y/120V 30 4W B3 B4 C3 City of Tukwila BUILDING DIVISION r 1 I I PDU -8 I � I I I I I I 75KVA l I L__,__I L4A NORTH CLOSET 100A MCB 2P2 100A MCB 115 MCA RTU -3 } I °` c.ryhnn, Plan review eggeovalbsubjectio MOM andareissions• Approval of con iU on daatinente does net authorize the violation deny adapted code°raanae. Receipt °improved - J =41. ;. . ,. .. isecimowledgeck 41.101 &WPM BY 200A J C4 125A ST City Of Tukw' all E -DING D ELEV ° � - - 1 -1 /4 "c,3#, SION REVVED FOR CODE COMPLIANCE NFPA 70 - NEC _/ 2 Lijud ,ry 125A ST ROOF ELEV 4TH FLOOR APPROVE) .. r- r. C47A� 1 7 ...!'t';_ " MOD F ED CR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING Orrl!':AL, ALI WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND IS I'?.';_ ^T TO r;`:; C INSPI SCHEDULE NOTES: 1. CONDUIT SIZING BASED ON RIGID GALVANIZED STEEL CONDUIT TYPE THHN -2 /THWN -2 AND XHHW WIRE TAKING INTO ACCOUNT BOTH CONDUIT FILL AND JAMB RATIO. 2. AMPACITIES LISTED ARE BASED ON THE FOLLOWING TAKEN FROM TABLE 310 --16. 3. INCREASE RACEWAY SIZE FOR OTHER TYPES OF RACEWAYS AND DIFFICULT OR LONG PULLS. 4. GROUND WIRE SIZE INCREASED FOR PARALLEL CONDUCTOR RUNS PER NEC TABLE 250 -95. 5. PROVIDE A SEPERATE ISOLATED GROUND CONDUCTOR ON ALL FEEDERS SHOWN. 6. INCREASE GROUND SIZE FOR GROUNDING ELECTRODES PER NEC TABLE 250 -94. A. 60' RATING FOR TERMINATION TO DEVICES © 100A OR LESS PER UL. B. 75' RATING FOR 3W AND 4W FEEDERS. C. 90" RATING FOR 5W FEEDERS DE-RATED TO 80% WHERE PREDOMINATLY HARMONIC CURRENTS ARE PRESENT. NEUTRALS > #1/0 ARE PARALLED ON 5W FEEDERS. ELO'7- 66$ Public Works, Building Division PERMIT NUMBER 0 7..6 APP' FLAG NOTES: 3 "H CONCRETE HOUSEKEEPING PAD. COORDINATE INSTALLATION REQUIREMENTS WIN SEATTLE CITY LIGHT. 3 PANEL PDU. 2 PANEL PDU. SQUARE D 2350 WITH IOM -4444 I/O MODULE. 0 PROVIDE A NEUTRAL CURRENT SUMMING SYSTEM THAT SENSES WHEN THE SUM OF THE NEUTRAL CURRENTS BETWEEN THE PORTABLE GENERATOR AND THE PERMANENT GENERATOR IS 1200 AMPS OR MORE AND WILL TRIP THE GROUND FAULT PROTECTION DEVICES ON THE CIRCUIT BREAKERS. APPROPRIATE SYSTEM SHALL BE DESIGNED AND PROVIDED BY THE SWITCHGEAR MANUFACTURER. SUBMIT DESIGN DRAWINGS FOR REVIEW BY THE ENGINEER. THE SYSTEM SHALL CONSIST OF ADDITIONAL CT'S, INTELLIGENT CURRENT SUMMING DEVICES, AND ALL OTHER DEVICES AND EQUIPMENT NECESSARY FOR PROPER OPERATION. RECEIVED Nov - 6 2007 PERMIT CENTER 2/2 PLOT: S BEY CONSULTANTS ARCHITECTURE VEC ISSUE DATE August 14, 2000 DRAWING TITLE: PROGRESS DATE: 06/14/00 FILE: E8.1. DRAWING NUMBER: EL EC T R IC CONSULTANT: VECA ELECTRIC 5614 7th AVENUE SOUTH SEATTLE, WA 98108 -0467 Ph (206) 436 -5200 Fx (206) 763 -0505 www.veca.com ASBUILT UPDATE 08/11/05 /1\ GENERATOR ROOM 08/14/00 REVISIONS All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the some may not be duplicated, used or disclosed without the written concent of the Sabey Corporation. Tenant Improvement for S: \Intergte \Bldg_C \Netstream \Copy of netlogo.gif at Intergate West 12101 Tukwila International Blvd. Tukwila, WA PROJECT NUMBER: 606302 DRAWN BY: CHECKED BY: TJ APPROVED BY: irE Q STANDBY POWER RISER DIAGRAM 1: \B1 0371 VADDV81.DWG I 8° (q sa /S \1 ` 125A H4 125 RTU3 125 ELV1 21 5 ELV2 s ° 225A HP N ROOF 4TH FLOOR LEVEL P -2 r 5N 4 2000A -4P 65KAIC TVSS REMOTE GENERATOR ANNUNCIATOR (IN UPS ROOM) DIGITAL METERING l ¢ 1 CD CO CD METERING COMPARTMENT PER SEATTLE CITY LIGHT REQUIREMENTS 5N 4 BYPASS/ ISOLATION SWITCH Nod & i J AC -1 Y' AC -2 AC -3 ` AC- 4 [f►1V T/IT d I F l H3 TO SCL F LIGHTNING ARRESTER r L ._ 3 G 7 1250KW/1563KVA ENGINE /GENERATOR 180KW ■nr- UPS (TYP) 180KW UPS (TYP) 5N4 8 2M 4 (2 N3 N3 LL I- Q¢ 00 00 UPS 1 9 UPS 2 SWBD 401 - DIGITAL FOREST 480Y/277V, 30, 4W, 65KAIC, 2000A SWBD MSB -2 - DIGITAL FOREST & BLDG COMMON LOADS 480V/277V, 30, 4W, 65KAIC, 2500A 12 MINUTE BATTERIES (TYP) 10 M4 12 MINUTE BATTERIES (TYP) 11 DC POWER (¢¢ 12 DIGITAL METERING DP2 - BLDG COMMON LOADS 800A 480V/277V,_30, 4W 65KAIC AI 2M 4 1 SYSTEM CONTROL CABINET DC POWER FUTURE 2M4 w I ¢ Q 0 0 EXTERNAL MAINTENANCE BYPASS H4 SOUTH CLOSET 125A MLO 00 0 00 15 r r C4 r p U4 800A TVSS 750KW LOAD BANK 2000A BUSWAY r 16 H3 00 00 C3 SWBD, G -1 - DIGITAL FOREST 480V/277V, 30, 4W, 65KAIC, 2000A STANDBY POWER RISER DIAGRAM SCALE: NONE PDU -1 75K VA C3 PDU -2 75K VA C3 , PDU -3 75KVA a a 4 4 a T -1 30 KVA 480V 208Y/120V 30 4W 63 B4 B4 w eE a l u-r ¢¢ (° to to NN 17 18 19 20 21 J MLO I G4 225A 75 KVA 480V 208Y/120V 30 4W II C3 ,'~ PDU -4 75KVA C2P4 100A MLO LP 225A MCB T � C3 , [PDU -5 75KVA H4A NORTH CLOSET 125A 4P2 MLO 225A MCB C3 PDU -6 75KVA C3 , PDU ---7 75KVA T- 2 30 KVA 480V 208Y/120V 30 4W B3 B4 - - • �.;,:r, -;c No r, Or?";s fi 'II ' rn of ,,,,fork prIor , NOTE: Revisions win requirr 9nd may Include aoditio jai T- 2 30 KVA 480V 208Y/120V 30 4W B3 B4 C3 City of Tukwila BUILDING DIVISION r 1 I I PDU -8 I � I I I I I I 75KVA l I L__,__I L4A NORTH CLOSET 100A MCB 2P2 100A MCB 115 MCA RTU -3 } I °` c.ryhnn, Plan review eggeovalbsubjectio MOM andareissions• Approval of con iU on daatinente does net authorize the violation deny adapted code°raanae. Receipt °improved - J =41. ;. . ,. .. isecimowledgeck 41.101 &WPM BY 200A J C4 125A ST City Of Tukw' all E -DING D ELEV ° � - - 1 -1 /4 "c,3#, SION REVVED FOR CODE COMPLIANCE NFPA 70 - NEC _/ 2 Lijud ,ry 125A ST ROOF ELEV 4TH FLOOR APPROVE) .. r- r. C47A� 1 7 ...!'t';_ " MOD F ED CR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING Orrl!':AL, ALI WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND IS I'?.';_ ^T TO r;`:; C INSPI SCHEDULE NOTES: 1. CONDUIT SIZING BASED ON RIGID GALVANIZED STEEL CONDUIT TYPE THHN -2 /THWN -2 AND XHHW WIRE TAKING INTO ACCOUNT BOTH CONDUIT FILL AND JAMB RATIO. 2. AMPACITIES LISTED ARE BASED ON THE FOLLOWING TAKEN FROM TABLE 310 --16. 3. INCREASE RACEWAY SIZE FOR OTHER TYPES OF RACEWAYS AND DIFFICULT OR LONG PULLS. 4. GROUND WIRE SIZE INCREASED FOR PARALLEL CONDUCTOR RUNS PER NEC TABLE 250 -95. 5. PROVIDE A SEPERATE ISOLATED GROUND CONDUCTOR ON ALL FEEDERS SHOWN. 6. INCREASE GROUND SIZE FOR GROUNDING ELECTRODES PER NEC TABLE 250 -94. A. 60' RATING FOR TERMINATION TO DEVICES © 100A OR LESS PER UL. B. 75' RATING FOR 3W AND 4W FEEDERS. C. 90" RATING FOR 5W FEEDERS DE-RATED TO 80% WHERE PREDOMINATLY HARMONIC CURRENTS ARE PRESENT. NEUTRALS > #1/0 ARE PARALLED ON 5W FEEDERS. ELO'7- 66$ Public Works, Building Division PERMIT NUMBER 0 7..6 APP' FLAG NOTES: 3 "H CONCRETE HOUSEKEEPING PAD. COORDINATE INSTALLATION REQUIREMENTS WIN SEATTLE CITY LIGHT. 3 PANEL PDU. 2 PANEL PDU. SQUARE D 2350 WITH IOM -4444 I/O MODULE. 0 PROVIDE A NEUTRAL CURRENT SUMMING SYSTEM THAT SENSES WHEN THE SUM OF THE NEUTRAL CURRENTS BETWEEN THE PORTABLE GENERATOR AND THE PERMANENT GENERATOR IS 1200 AMPS OR MORE AND WILL TRIP THE GROUND FAULT PROTECTION DEVICES ON THE CIRCUIT BREAKERS. APPROPRIATE SYSTEM SHALL BE DESIGNED AND PROVIDED BY THE SWITCHGEAR MANUFACTURER. SUBMIT DESIGN DRAWINGS FOR REVIEW BY THE ENGINEER. THE SYSTEM SHALL CONSIST OF ADDITIONAL CT'S, INTELLIGENT CURRENT SUMMING DEVICES, AND ALL OTHER DEVICES AND EQUIPMENT NECESSARY FOR PROPER OPERATION. RECEIVED Nov - 6 2007 PERMIT CENTER 2/2 PLOT: S BEY CONSULTANTS ARCHITECTURE VEC ISSUE DATE August 14, 2000 DRAWING TITLE: PROGRESS DATE: 06/14/00 FILE: E8.1. DRAWING NUMBER: EL EC T R IC CONSULTANT: VECA ELECTRIC 5614 7th AVENUE SOUTH SEATTLE, WA 98108 -0467 Ph (206) 436 -5200 Fx (206) 763 -0505 www.veca.com ASBUILT UPDATE 08/11/05 /1\ GENERATOR ROOM 08/14/00 REVISIONS All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the some may not be duplicated, used or disclosed without the written concent of the Sabey Corporation. Tenant Improvement for S: \Intergte \Bldg_C \Netstream \Copy of netlogo.gif at Intergate West 12101 Tukwila International Blvd. Tukwila, WA PROJECT NUMBER: 606302 DRAWN BY: CHECKED BY: TJ APPROVED BY: irE Q STANDBY POWER RISER DIAGRAM 1: \B1 0371 VADDV81.DWG