Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL07-687 - CLOUD NINE
CLOUD NINE 17302 SOUThCENTER PY EL07-687 Parcel No.: 2623049024 Address: Suite No: Cit;►.if Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17305 SOUTHCENTER PT TUKW Tenant: Name: CLOUD NINE Address: 17305 SOUTHCENTER PY, STE 100 , TUKWILA WA Owner: Name: TR5 LLC Address: 117 E LOUISA ST #230 , SEATTLE WA Contact Person: Name: CLINT MCCUBBIN Address: 4314 103 AV SE , EVEREIT WA Contractor: Name: NORTHLAND ELECTRIC INC Address: 4314 103 AV SE , EVEREIT WA Contractor License No: NORTHEI21879 DESCRIPTION OF WORK: TENANT IMPROVEMENT FOR RETAIL STORE Value of Electrical: $19,455.00 Type of Fire Protection: Electrical Service provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie The granting of this permit does not pres construction or the nerjGrmanne of wor Signature: Print Name: doc: EL -4/07 PUGET SOUND ENERGY ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 377 -1514 Phone: 425 377 -1514 Expiration Date: 03/31/2009 EL07 -687 11/27/2007 05/25/2008 Fees Collected: $512.50 National Electrical Code Edition: 2005 Date: t 0E1401 21401 ed permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating authorized to sign and obtain this electrical permit. Date: / z o 9- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. EL07 - 687 Printed: 11 -27 -2007 1: ** *ELECTRICAL * ** Signature: Print Name: doc: Cond -Elec City of Tukwila Parcel No.: 2623049024 Address: 17305 SOUTIICENTER PY TUKW Suite No: Tenant: CLOUD NINE Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: EL07 - 687 Status: ISSUED Applied Date: 11/14/2007 Issue Date: 11/27 /2007 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: EL07 -687 Printed: 11 -27 -2007 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htth://www.ci.tukwila.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION © /V King Co Assessor's Tax No.: Vi .) Site Address: (7 O s Sb a I h c� e n ,.r 7 c1w 1-�Ot J Suite Number: 1 t Floor: Tenant Name: ( )V u cl 1J i /O e-- New Tenant: El Yes ❑ ..No Property Owners Name: 6 e c k e r he U e I op jvi.e n' 4 (to„ STt u. c-T,o N C a Mailing Address: I 1 7 £a ST U ( $A- Si ' 4 23b gpa7f /e W A- 9 21O D- City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: C Mailing Address: 43 I(4 1 (Y3 • S E E -Mail Address: ELECTRICAL CONTRACTOR INFORMATION Company Name: j D I`7 I Art c� a < ' rr' � cTfr, C (` Mailing Address: 8 -1 3 1 I V3 h-' f C -S� Contact Person: l I I N Jn (I Cu T / N E -Mail Address: r7 I L @ O C R l Z Od• NE 7' Contractor Registration Number: 0)0 i-I t 1 r a I ' 7 7 4 ,/ Valuation of Project (contractor's bid price): $ J 1 'I 5 / 1 co Scope of Work (please provide detailed information): n a n I m l 0 / v v � 1'Yl e CloKF 10,0e R ef &' I Siy Property Served by: lg. Puget Sound Energy ❑ Seattle City Light H°.Applications\Forms- Applications On Lineal -2007 - Electrical Permit Application.doc bh siwo Electrical Permit No, OA* WI" I Project No. (For office use only) e /e7 City Day Telephone: Fax Number: Expiration Date: Day Telephone: 77 - /.57 £0 te F7 W,1- '06 City State Zip , Fax Number: a � ) .3 7 7 - ? / 7 W,A 9flt S State Zip - ►3 ? -isi 377 -9V/ 3 f 31 /a©c' Will service be altered? ❑ Yes No Adding more than 50 amps? I& Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service ❑ Remodel Tenant Improvement Page 1 of 2 • RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) BUILDING OWNER S e ELECTRICAL CONTRACTOR: Signature: iG Print Name: ` 1 l 1 An Lk 9 / t � / Mailing Address: Lf 3 I / I D'-'3" ate A--u e S I Date Application Accepted: 1(I ( (4f 01— H: Applicalions\Forms- Applications On Line14 -2007 - Electrical Permit Applicationdoc bh Date Application Expires: MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Day Telephone: (L( s) 3 57 Y rt 18,90-S City state Zip 6 tikv72 Date: 11--/ (-1-0 Staff Initials: dur"..-- Page 2 of 2 Receipt No.: R07 -02492 Initials: JEM User ID: 1165 ACCOUNT ITEM LIST: Descript ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES Payee: NORTHLAND ELECTRIC INC TRANSACTION LIST: Type Method Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049024 Permit Number: EL07 -687 Address: 17305 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 11/14/2007 Applicant: CLOUD NINE Issue Date: Amount Payment Check 32368 512.50 Account Code Current Pmts 000.322.101.00.0 410.00 000.345.832.00.0 102.50 Total: $512.50 Payment Amount: $512.50 Payment Date: 11/14/2007 12:04 PM Balance: 50.00 4968 11/14 9710 TOTAL 512.50 doc: Receiot -06 Printed: 11 -14 -2007 Project: CI-0/1 A A) / NI- Type of Inspection: Address /?30,5 --CarNadre/Z / Date Called: Special Instructions: ' Date Wanted: /eXii 3 A Requester: Phone No: k407 INSPECTION NO. PERMIT,140. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-36 0 CITY OF TUKWILA BUILDING DIVISION Ilnspect6 A rremmigH INSPECTION RECORD Retain a copy with permit COMMENTS: 0/<- filvfiL proved per applicable codes. El Corrections required prior to approval. 1 Date: 2 //- 7 /6 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: C-40 A- Type of Inspection: � Address: i r.it /72 . ✓T k' Date Called: `/ . Special Instructions: Date Wanted: _ / �5_ ' a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION ' 6300 Sout hcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 p roved per applicable codes. Corrections required prior to approval. OMMENTS: fig 94 - 'Inspect3 Arivamie‘ r/ I /lO El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: ACTIVITY NUMBER: EL07 - 687 DATE: 11 -14 -07 PROJECT NAME: CLOUD NINE SITE ADDRESS: 17302 SOUTHCENTER PY, STE 100 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: ` ��� Buffng Di visn Public Works ❑ `-'PERMIT COCA) COPY `" PLAN REVIEW /ROUTING SLIP DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 Fire Prevention Structural Incomplete ❑ Planning Division n ❑ Permit Coordinator n DUE DATE: 11 -15 -07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 12 -13 -07 n Approved ❑ Approved with Conditions [Y] Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License NORTHEI21879 Licensee Name NORTHLAND ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 600344369 Ind. Ins. Account Id Business Type CORPORATION Address 1 4314 103RD AVE SE Address 2 City EVERETT County SNOHOMISH State WA Zip 98205 Phone 4253771514 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 10/29/1979 Expiration Date 3/31/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License MCCUBCM970RH Business Owner Information Name Role Effective Date Expiration Date HECKMAN, DAVID G 01/01/1980 MCCUBBIN, CLINT M JR 01/01/1980 HECKMAN, DAVID G AGENT 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Master Electrician Information License Name Status MCCUBCM970RH MCCUBBIN, CLINTON M JR ACTIVE https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= NORTHEI21879 11/27/2007 Project info Project Address . .... Date 11/1312007 . , . .. ... , . .. . , . , .. , For Brsrldiricl ep ftmer'rt Las. Ap plicant Name: , .. ..� . .., , , ..... .. . • ...- ,. • . Applicant Address: • , .... ... . . , , . Applicant R nne: • , • • • , , • � . , 0 O !l: •1. 'Jr 11► IG GFI LIGHTING 1 FLUORESCENT STRIP FIXTURE, DRAWN TO SCALE FIXTURE CEILING MOUNTED FIXTURE WALL MOUNTED FIXTURE RECESSED CAN 0 TABLE LAMP E FIXTURE SUPPLIED FROM EMERGENCY CIRCUIT ® EXIT SIGN - DIRECTIONAL ARROWS AS INDICATED, SHADED SIDES ILLUMINATED EMERGENCY WALL MOUNTED LIGHT EMERGENCY CEILING MOUNTED LIGHT WALL PACK FIXTURE WALL MOUNTED SWITCH - SINGLE POLE SUBSCRIPTS a,b, etc., DENOTES CIRCUIT CONTROLLED 3 3 WAY SWITCH 24 HOUR TIMER ® SMOKE DETECTOR KD SMOKE DETECTOR - WALL MOUNTED RECEPTACLES (1) SINGLE RECEPTACLE 120V �Ih DUPLEX RECEPTACLE 120V, "D" = DEDICATED CIRCUIT DUPLEX RECEPTACLE 120V, MOUNTED 3" ABOVE COUNTER BACKSPLASH 4 DOUBLE DUPLEX RECEPTACLE 120V TWIST LOCK RECEPTACLE 120V DUPLEX RECEPTACLE 120V, EMERGENCY CIRCUIT DOUBLE DUPLEX RECEPTACLE 120V, EMERGENCY CIRCUIT SPLIT WIRED RECEPTACLE, 120V, TOP SWITCHED • SPECIAL RECEPTACLE ( TYPE AS NOTES) FLUSH FLOOR OUTLET (DEVICES AS INDICATED) COMBINATION OUTLET (DEVICES AS INDICATED) DUPLEX RECEPTACLE - ISOLATED GROUND TYPE DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE DRAWING INDEX E0.1 TITLE SHEET E1.1 FLOOR PLAN E1.2 LEVEL 1 - POWER & LIGHTING & PANEL SCHEDULES E2.1 ONLINE SERVICE DIAGRAM E LECTRICAL SYST 17305 SOUTHCENTER PARKWAY T(JKVVILA WA_ 981 88 O XXX > ACH AFF AFP AG A, AMP ATS AWG CB CKT CTB DED DW EWC FA FBOIC FT G, GND GD GFI, GFCI HP IH s ELECTRICAL RISER CABLE TO BUS CONNECTION FUSE OR CURRENT LIMITER GROUND CONNECTION EQUIPMENT PANEL - 208 VOLT SYSTEM PANEL - 480 VOLT SYSTEM ® TRANSFORMER ABBREVIATIONS y AVAILABLE SHORT CIRCUIT CURRENT AW MOTOR CONNECTION 3 PHASE ABOVE COUNTER HEIGHT ABOVE FINISHED FLOOR ARC FAULT PROTECTED ABOVE GRADE AMPERE AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GAGE CIRCUIT BREAKER CIRCUIT COMMUNICATIONS TERMINAL BOARD DEDICATED DISHWASHER ELECTRIC WATER COOLER FIRE ALARM FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR FEED THRU GROUND GARBAGE DISPOSAL GROUND FAULT CIRCUIT INTERRUPTER HORSEPOWER INSTA -HOT WATER DISPENSER / FUSED SWITCH CIRCUIT BREAKER DRAWOUT CIRCUIT BREAKER CIRCUIT BREAKER - GROUND FAULT PROTECTION IDENTIFICATION SYMBOL FOR FEEDER SIZES TRANSFORMER O WATT -HOUR METER TRANSFER SWITCH ENGINE - GENERATOR bo ® ® E EQUIPMENT CONNECTION, E = EMERGENCY POWER kY MOTOR CONNECTION SINGLE PHASE J -BOX MW MB M LO N NIC PNL R RO RECEPT REF SPECS SW SWBD TELE TYP V VP W WP XFMR 0 JUNCTION BOX MICROWAVE MAIN BREAKER MAIN LUG ONLY NEUTRAL NOT IN CONTRACT PANEL RACEWAY RACEWAY ONLY RECEPTACLE REFRIGERATOR SPECIFICATIONS SWITCH SWITCHBOARD TELEPHONE TYPICAL VOLT VANDALPROOF WIRE OR WATT WEATHERPROOF TRANSFORMER PHASE s Abbrev FUSED SWITCH (FUSE RATING INDICATED) ID DISCONNECT SWITCH ® MOTOR STARTER - MAGNETIC IR COMBINATION MOTOR STARTER DISCONNECT SWITCH 0 THERMOSTAT IN TIME CLOCK 0 PHOTOCELL CONTROL 0 ENCLOSED CIRCUIT BREAKER X RECEPTACLES LIGHT SWITCHES CLOCK OUTLET PANELBOARDS ELECTRIC HEAT BASEBOARD HEATER CONNECTION (KW INDICATED) CONTROL GENERAL NOTES 0 FLAG NOTE / (REVISION SYMBOL ELECTRICAL DETAIL SYMBOL OUTLET MOUNTING HEIGHTS 0 a Rio 9. PROVIDE SERVICE GROUNDING PER NEC. 10. PROVIDE ASTROLOGICAL TIME CLOCK TO WORK ALL BUILDING AND SITE EXTERIOR LIGHTING. WORK DEFINITION SPECIAL OUTLET HEIGHTS ARE SHOWN ON THE ELECTRICAL DRAWINGS OR ON THE ARCHITECTURAL DRAWINGS. IF SPECIAL OUTLET HEIGHTS ARE NOT SHOWN OR REQUIRED, THEN LOCATE OUTLETS AS NOTED BELOW. OUTLET HEIGHTS ARE MEASURED FROM THE FINISHED FLOOR TO THE CENTERLINE OF THE OUTLET UNLESS OTHERWISE NOTED. +18 INCHES VERTICAL +4 FEET SET VERTICAL -I-6 FEET, 8 INCHES +6 FEET TO TOP OF PANELBOARD SEPARATE PERMIT REQUIRED FOR: If M echanical Pilectrical Plumbing qr Gas Piping Ci ty of Tukwila BUILD DIVISION 1. COMPLY WITH NATIONAL ELECTRICAL CODE 2005 EDITION AND WAC 296 -46. 2. THE LOCATIONS OF ELECTRICAL DEVICES OR LIGHTING FIXTURES INDICATED ON ARCHITECTURAL PLANS ELEVATIONS OR SECTIONS TAKE PRECEDENCE OVER LOCATIONS INDICATED ON THE ELECTRICAL DRAWINGS. 3. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LIGHTING FIXTURE LOCATIONS. 4. HVAC EQUIPMENT SHOWN IN APPROXIMATE LOCATIONS. REFER TO HVAC PLANS FOR EXACT LOCATIONS. 5. ALL NEW WIRE IS #12 THHN /THWN COPPER UNLESS OTHERWISE NOTED 6. FUSE /PROTECT ALL MECHANICAL EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS AND CODE REQUIREMENTS. 7. ALL UTILITY ROUGH -IN WILL BE COORDINATED WITH LOCAL UTILITY COMPANIES. 8. COORDINATE AND OBTAIN MAXIMUM AVAILABLE FAULT CURRENT FROM POWER COMPANY. ALL SERVICE EQUIPMENT WILL BE RATED AND COORDINATED FOR MAXIMUM AVAILABLE FAULT CURRENT. S 1'.ti St S 51't?s Sz 5i St a 17;�rid rnE aa r V .7 5, ixef X13! iS4fiSff ititrri G?r .1.giefira I r ruraDA wr.tt ' rxirpotaM fk 5 ft Pien VICINITY MAP Lighting Summary LTG-SUM Note new autorrratic dayIightiri , occupancy sensor. and other control rrqu; etnents of Section 1513, as applicable. Project Description Compliance Option APPROVED Pt " . �r'rrrr CATrn�rc eu',l L PrI r TT C! tANGGED, MODIFIED OR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING OrFICIAL, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND IS SUBJECT TO FIELD INSPECTIONS Alteration Exceptions (check appropriate box) REVISIONS No Changes shall be made too el COO o f work without prior app Tukwila Building Division_ NOTE: Revisions will require a new plan submittal and may include additional plan reVteW fees cm Maximum Allowed Lighting Wattage (Interior) Location (floor/room na.) Occupancy Description Retail lea Allowed Watts per ft' " 1.50 From Table 15-1 over) - docurr:ent all exceptions on form LTQ -LPA Totals Area in ft= 4467. 4407.4 AlEow ed x Area 6ii (3.5 6610.5 Proposed Lighting Wattage (MO Location (f €oorfroon no.) 1?�t1 Bathroom 2 4 lay in. tropher Bath Bar Light Q No changes are Ming made to the lighting Fixture Description Total Proposed Watts may not exceed Total Allow ed Watts for interior Maximum Allowed Lighting Wattage (Exterior) New Building ❑ Addition A €tetationf Bldg, >5,000 sq.ft. (auto shutoff reci 0 Plans include Refer to SEC Sacfion 1513 for controls and Corn r'r is stonirrr requireme11S. FILE COPY Permit No. BUILDING of lbkwfla DIVISION O Prescriptive 0 Lighting Power Allowance C) Systeres Analysis 0 Clear (See Qualification Checklist (over). indicate Prescriptive • LPA spaces clearly on plans.) • <6014, of futures new . installed ilg w attage not Increased. and Table 15-1 use is not Not on Proposed Lighting Wattage: 1, Use manufacturer's listed maximum input wattage. For hard -w fired ballasts only. the default table in the NREC Technical Reference Manual my also be used 2. Imlude exit lights exceeding 5.0 w a#ts per fixture. 3. List aM € inures For exempt Etoritine not exception on applicable fixtures Public Works, Building Division PERMIT NUMBER 07 APProw Number of Fixtures review approved subiscitosnossiodontissions. movel of Cons/Mon dosumssts doss not r io fze 4 vidationdonyadoptedcodoortichnosilisosipt of approved , ter :. telaeimo egad: 59 1 Watts; Fixture 73.01 Total Proposed Watts Watts Propose 4307.0 1 80. 0 4487.0 Location Covered Parking Note: 2001 SEC does not allow trail ng bete eon covered parldngs and exl. ltg. Open Parking Outdoor Areas Bldg (by facade) Bldg. (by perm) Description Note: choose either the facade area or the perimeter method but not both. Mow ed Watts per ft= of per if 0.2 Wfft Total Allowed Covered Parking Watts 0.15 WIft 0.15 Mt= 015 Mft 7.5 t+�1tlf Area in ft or if for perimeter) Total Allowed Ettrig, Exterior Watts Ally t edWatts x ft= (or x 1) Use rrifgr listed maximum input wattage. For fixtures w ith hard - )red ballasts Proposed Lighting Wattage (Exterior) only, the default table in the NREC Technical Reference Manual may also be used Watts Proposed Location Fixture Descriptbr3 Total Proposed Watts may not exceed Total Allowed Watts for Exterior No. of Fixtures W tts ?' Fixture Total Prvpas Watts RECEIVED CITY OF TUKWILA NOV 14 20071 r ri\ITEt: a014Z 1 DRAWING ONLY TO SCALE IF PLOTTED AT 24" X 36" 10011 North Fleetwood Street 5 po lkeine., WA 99205 Phon : (5O9) 466 -2936 Fax: (5O9) 466 -2937 email: spakaneoff @safeconsulting.biz INSTALLING CONTRACTOR: NORTHLAND ELECTRIC 4314 103RD AVE_ .SE. EVERETT, WA_ 98205 Phone,: (425) 377 -1514 Fcxx: (425) 377 -9414 z 0 In w 0 D 0 J U DRAWN BY: Doug Burton CHECKED BY: Adrian M. Steik PLOT DATE: 11 -13 -2007 PROJECT NUMBER: 07 -087 _SHEET NUMBER: E0.1 FILE COPT' i L • I EXISTING LAY Z BOY FUR \ITURE I L =.1 L.1 PLAN T A FLOOR SCALE =1/8" -1O CLOUD 9 RETAIL I REVIEW MP �NCE CODE C NFPA 70 - NEC N1 6 2001 C►t 0 � ukwiia BU1 SON . taV REcerveo CITY OP WKWILA NOV 1 2007 P ER &A: �� �\\ \N N \ z, \• V N Nry 10011 North Fleetwood Street Spokane, WA 99208 Phone: (509) 466 -2936 Fax: (509) 466 -2937 email: spokaneoffice@safeconsulting .biz INSTALLING CONTRACTOR: NORTHLAND ELECTRIC 4314 10380 AVE_ SE. EVERETT, WA_ 98205 Phone: (425) 377 -1514 Fnx: (425) 377 -9414 O DRAWING ONLY TO SCALE IF PLO1 I ED AT 24" X 36" SHEET NUMBER: z J 0 .1 DRAWN BY: Doug Burton CHECKED BY: Adrian M. Steik PLOT DATE: 11 -13 -2007 PROJECT NUMBER: 07 -087 E1.1 Panel: 106-A Mn ai Bus 200A Panel Location : West Wail Space 106 Panel Location : West Wail Space 106 Main Lug 200 amps 120/208 3 -Phase Ckt. No Load Description ha 1 AC -7 5,50 Trip Amps 60 60 Phase A :Trip Amps 20 kva 1.10 Load Description Ckt. No. Lighting 2 Lighting 4 3 5.53 B 20 110 5 530 50 C • 20 1,10 110 Lighting 6 Lighting _ `_.._._ _. 7 Roof WP CFI 0.36 20 A 20 9 5 i 20 1.60 10 11 3.60 C 50 C 12 1.60 Show Window 6 8 7 15 2.25 B 30 A � ��� 17 Duplex Receptacles C 2.25 18 19 21 B A 8 C 20 22 23 24 25 27 A 1 2 14 15 28 a 16 18 20 22.. 24 26 28 33 36 B • C: 6 34 36 �.._... C ..._.-..._ A 37 __ .__ _________ Y .... _ _ .. �. 38 4 - ' ..._.._ : -4- - -._ . �w -._ -. _ ........ ._...._ ....................... .......�. _ _ _ . Total K'w = Connected Loads 16 86 4.40 Total kw =' C 25 21.26 0.00 A 0.00 27 0.00 0.00 4.40 Total Amps Total kw =. Demand Loads 16.86 4,40 59.06, Panel: 106 -B Main Bus 200A Panel Location : West Wail Space 106 Main Lug 200 amps /2€3:208 3 -Phase • Ckt, No, Load Description kva 3.60 Trip Amps 50 Phase A Trip Amps 20 kva 1.60 Load Description Show Window Show Window . Ckt. No. 2 4 1 AC-6 3 " 3.60 50 i 20 1.60 • 5 3.60 50 C • 20 1.60 Show Window 6 8 7 HWT 2.25 30 A 20 1.26 Duplex Receptacles 9 2.25 30 B 10 1 1 13 C A _...._. 1 2 14 15 a 16 18 20 22.. 24 26 28 17 C: 6 19 21 _ _ _ . 23 C 25 A 27 B 29 C 30 31 A 32 34 33 �. B C 35 36 37 A 8 C 38 40 42 39 41 Total kw = Connected Loads 15.30 6.06 Total kw w 21.36 0.00 0.00 /3.00 0.00 6.06 Total Amps Total kw = Demand Loads 15.30 6.06 59,33 Panel A €C Rating 10K Panel MC Rating 10K PANEL SCHEDULE PANEL SCHEDULE Fed From Panel MDP Fed From Panel MOP 106 -B -7,9 106 -B -8 L v LL d b b A F1 F1 F F Fl F F1 Fl 1 FLOOR PLAN - LIGHTING & POWER SCALE = 3/16" -1' -O" d b b b 1 Fl Fl F F F F F Fl F d Fl b b 1 F Ti F1 F 106 -B -2 F C F d F1 F F F b 106 -A -2 106 -A -4 106 -A -6 106 -A -8 F C F d F Fl b F1 Fl b 106 -B -4 Fl X F d F Fl b F F b 106 -B -6 9 DJI HI RECEIVED Cam` OPT! l OVRA NOV 14 2007 'E DRAWING ONLY TO SCALE IF PLOTTED AT 24" X 36" CO31- \ \� V 10011 North Fleetwood Street 5poknn, WA 99208 Phone: (509) 466 -2936 Fax: (509) 466 -2937 email: spokaneofficec safeconsulting .biz INSTALLING CONTRACTOR: w 0 NORTHLAND ELECTRIC 4314 103RD AVE. SE. EVERETT, WA_ 98205 Phone: (425) 377 --1514 Fax: (425) 377 -9414 CD 1 0 M h w 0 VIEWED FOR E C FPA 70 -NEC NOV 2 6 2001 OMPLIANCE City Of Tukwila 1/••••■■•••iiiii ILDING DIVISION 0 0) z >- c o < F 0 7 I a � V WQ � W Z � J Q D 5 J 1 (9 O' MD O 0 DRAVTh BY: Doug Burton CHECKED BY: Adrian M. Steik PLOT DATE PROJECT NUMBER: 07-087 E1.2 SHEET NUMBER: 11 -13 -2007 O 0 J 200 a . 200 , 200 R .�. �@ l ^S ` . F J �, ., ., A ( (0 a (o) , Z.» . 6» ) 00 DA 100 — /' ! V L 00 11% t (chi) a (6) a - 00 ---?1/ --1 2 9 7 3 i 0 AL N U 000 00 =' A \ L 1C0 —v .'O()A C, O U °o G 0 0 (P)) V V (c)) a )(fl M C. v AL C R N J R VC 60 A T T RA\ RA RA RA —\ A A V AL \, 0 F - C- F v o9 [n] 200 200 200 ) v GPI TT v1 A L. � 3LA 50 U0A CCA 20A. CCCCCAC OC :090A3 ((;-) (0) 0 (0) 0 ( l (, >) Q ? 0 0 100 —O O( V L) AC A' AO 51J 'LA0150 AC C LAO 5J —.LAO CU )OA I-1 I, \ ((a 6 (0) " (�1f :ao 00 0. ,1 (co °00 #� c 1 1 E L FR (:i. N L) 0050 7//90 % /(--J,9 SJ/70 5J/ 70 5C //0 /15 Q/ 00 0 eiD ° L ° o° O° G° Go o° o° Lir ��•, 0o (( rl (1 (0 0 00 00 0 00 CA\ O6 —B ''()(.)A ` O o o 0 °o 0 D D e qO A Z I I 6—L" PVC 3 -00 1 300V CV AL \ V CV VOL AOF 05 205/ 05 /C 208 205/' C0S /3 20 / 3 (67) 0 , , (0)( - ) AL 0 0 0 0 _) A 50 =C 60 5H ID C 50 0 0 C, 2 . O OG 0. w , (c?)) 0a 25,814 SO, X3 WA /77/7 45555 2000 20,000 - -' 1 BO --- R 80 VA 1?00 -A . 500 ?00 S� 1400 . -1 1 4800-12 500 8 00 5 LXT 440 8 CO 500 3500 GENERAL NOTES: SERVICE IS TYPE SQUARE D AND IS SERIES RATED WITH A 65K MAIN AR TS A SC)ARF VAC © C RC HC R!A 07 OW W A CO\ ROL =)A \ T« \ AC— C)_ - T - R COARP SSO C 3) VO — XT LXT RXT- R V R \ U 0 U - 1 H WA 0 W A RO RCD OR OR R —C _\ —\C; S C\ T`S (S\ DOW — C- -no T A D O — (7.4 ©4E:0 WA _T. TS WALL_ SACKS ©43C WA S — SS L C 41 00 WA TS OJT F -- 1 C Y _ . C 7180 W A T I S C:)' 00 WA IA\ —R ROOV REVIE CODE NFPA - NEC N NOV 2. 6 2007 C�tY pf Tukw`5�.0�1 EU1�DING D� WA- (di T RECEIVED cri OF TI NOV 14 2007 DRAWING ONLY TO SCALE IF PLOTTED AT 24” X 36" i \ Ser tA‘ 10011 North Fleetwood Street 5p•kan, WA 99208 Phone: (509) 466 -2936 Fctx: (509) 466 -2937 email: spokaneoffice @safeconsuIting.biz INSTALLING CONTRACTOR: NORTHLAND ELECTRIC 4314 103RO AVE_ SE. EVERETT, WA_ 98205 Phone: (425) 377 -1514 Fcix: (425) 377 -9414 w I- 0 m r, M z 0 w J 0 D 0 J Q� IY CO D I (±)<- Loy U 0 W Z W Z 0 J Q 0 U w J W DRAWN BY: Doug Burton CHECKED BY: Adrian M. Steik PLOT DATE 11 -13 -2007 PROJECT NUMBER: 07 -08 7 E2.1 SHEET NUMBER: