Permit EL07-734 - FAMILY FUN CENTER - WORLD HEADQUARTERS
FAMILY FUN CENTER WORLD HEADQUARTERS 7100 FUN CENTER WY ELO7-734 Parcel No.: 2423049092 Address: 7100 FUN CENTER WY TUKW Suite No: City,.:,f Tukwila epartment of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.citukwila.wa.us ELECTRICAL PERMIT Tenant: Name: FAMILY FUN CENTER WORLD HEADQUARTERS Address: 7100 FUN CENTER WY , TUKWILA WA Owner: Name: 112 OFFICE LLC Phone: Address: 7300 FUN CENTER WAY , TUKWILA WA Permit Number: EL07 -734 Issue Date: 12/19/2007 Permit Expires On: 06/16/2008 Contact Person: Name: ALEX KOROLENGKO Phone: 425 869 -7170 Address: 18342 REDMOND WY , REDMOND WA Contractor: Name: ALEXANDERS ELECTRIC INC Phone: Address: 18342 REDMOND WAY , REDMOND WA Contractor License No: ALEXAEI964L9 Expiration Date: 06/29/2008 DESCRIPTION OF WORK: INSTALL LIGHT FIXTURES, CONVENIENT OUTLETS, AND PHONE/DATA Value of Electrical: $8,000.00 Fees Collected: Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: $266.50 Date: /e-2 /ll k7 v i I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am auth Arized j n and obtain this electrical permit. Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL - 4/07 Date: // / 1f/P cR o - o EL07 -734 Printed: 12 -19 -2007 1: ** *ELECTRICAL * ** doc: Cond -Elec City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 2423049092 Permit Number: EL07 -734 Address: 7100 FUN CENTER WY TUKW Status: ISSUED Suite No: Applied Date: 12/03/2007 Tenant: FAMILY FUN CENTER WORLD HEADQUARTERS Issue Date: 12/19/2007 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. ( /� Signature: Date: < / / _,/ Print Name: /9 i/r 00/. 1 O fz e'E/ti c) EL07 -734 Printed: 12 -19 -2007 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION -� / King Co Assessor's Tax No.: � { 7- 30 ' 90 C t 2. ` Site Address: ` ` Q � �' �' % F lid 6 Nf 2Q Will Suite Number: 10 0 Floor: 1 - /e 2S New Tenant: IV Yes ❑ ..No 761-w (41 Cit wog State Zip Name: Ale -.4C ko ( j e r✓ Day � �ZS g C _/ 71 7 0 Mailing Address: I A 2 ►Jri.cc W , A Gt' j/lir CJ�L 0( f� a' 0J Z- ty State Zip E -Mail Address: C Z.k. erS EL � J V e r i • 2 On) i N e i . Fax Number: ( - L2C ) S 6 q 73 O ELECTRICAL' CONTRACTOR INFORMATION Company Name: 74 1- e 147 �� r' E /ec...572lC , /N e. Mailing Address: I S 3 4 Z QaA'✓L.-0 ,,,/4 w Qcp -0 K-0( U 9F9S City State zip Contact Person: 4(64c /--,c) Co( e N t Go Day Telephone: S ) g 6 g -7(70 E -Mail Address: 0-1 e ? � Q . /t. al e r5' et € V ( f zo/t/ . NQ % Fax Number: 0 - / 2 . 5 - ) 86 QJ - 730 3 Contractor Registration Number: /9 sF ( .* 96 41 L- 9 Expiration Date: Valuation of Project (contractor's bid price): $ t g r O 'o Scope of Work (please provide detailed information): / PC-1-1" fig 1 ■ Ui ti e acA_ 7/ S Pkow -- +1 Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: T eofw k: New ❑ Addition ❑ Service Change ❑ Remodel Tenant Improvement Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property erved by: Puget Sound Energy ❑ Seattle City Light H: ApplicanonsWorms- Applications On Iine\4 -2007 - Electrical Permit Application.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) Signature: Print Name: Mailing Address: I Date Application Accepted: e4C 1'(4r YliOe�% l$3(4 R. wity 1140401- H:\Applications\Forms- Applications On Line\4 -2007 - Electrical Permit Application.doc bh MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOT Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OF .ECTRICAL CONTRACTOR: Day Teie hone: R City Date: 1/ . 3 0 28D 7 ir6'M 0 L474- '' S'v c2_ State Staff Initials: Zip Date Application Expires: t/(p I t29 r 03 Page 2 of 2 1 Payee: ALEXANDER'S ELECTRIC, INC. ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2423049092 Permit Number: EL07 -734 Address: 7100 FUN CENTER WY TUKW Status: PENDING Suite No: Applied Date: 12/03/2007 Applicant: FAMILY FUN CENTER WORLD HEADQUARTERS Issue Date: Receipt No.: R07 -02639 Payment Amount: 3266.50 Initials: JEM Payment Date: 12/03/2007 11:29 AM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 8714 266.50 Account Code Current Pmts 000.322.101.00.0 213.20 000.345.832.00.0 53.30 Total: $266.50 5602 12/03 9710 TOTAL 266.50 doc: Receipt -06 Printed: 12 -03 -2007 Project: filmy rim 1 c-tnirm. Type of Inspection: Address: Fov ‘,...w../x4 w) Date Called: Special Instructions: Date Wanted: t P.m. Requester: Phone No: a INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. r CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 v Ilnspe proved per applicable codes. El Corrections required prior to approval. ) 1-1 611"11 Date: fl $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: !Date: • COMMENTS: Type of Inspection: _..., _ . / ..,_. /4 ; Date Called: t c-4/t// & C-inte Special Instructions: Date Wanted: " Requester: C-/A) - At (-45/7X /.19 - 7 - 0,-(/ /4 CA /f/ NoT CC S%2/Z7 A y 77-/E C__t4/14 fral -- 130, , To (?- 1,4)/7 yet" Project: (19/WAY Am/ 61417.4 Iti,4 Type of Inspection: _..., _ . / ..,_. /4 ; Date Called: Address: ,- 2 7/(70 ill/li (-1 41W , IN Special Instructions: Date Wanted: " Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. IT NO. CITY OF TUKWILA BUILDING DIVISION 7 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 -3 67Q j proved per applicable codes. Insper: ea 74/ (441 erections required prior to approval. D a t e# /e $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: iiio Type of Inspection: 70 3 Address: ljy Date Called: Special Instructions: Date Wanted: / / v a.m. p.m. Requester: Phone No: l '° 7 -7 3 1, / INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 proved per applicable codes. Corrections required prior to approval. : OMMENTS: P/ Inspecto ��116G 6TfQ4' f/ I /2 - /3"C /O 0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: 41e x+i-NJer`s Elea ktC , t IIJ c. (242, ge motic� W �-Y cod , vJ4 ci%OS Is) - 869 -71 7o txr ST/ r2 PA NQG -. tiDace i'ANEL_ IThL. t Izo Flex too R JZofa0$ # / 4L 3� ToPsEUf ti L' PVc. 25L) wzma AL LI seT Soo k -mit R t E . i1 St p ki et MA-I T d /ao A Ps 120/202, 3qS T ie. zc. 4. to(Z*" wets lot , i 2. 2' E too ia- M•( EM9ilNS PR14•f5 IR'1• 2-c>0 ZO /log 34 u t.) ro3, ( 0 m• 5 200 FA I 200 m. a. rn '8 To &tck S* Pro \e ; 2 "e /4r 2So[e-oc AL. E /ovy In NNSERyrC.r; RECEIVED CITY OF TUKWILA DEC 1012007 PERMIT CENTER ro -ru t y r�IJ 620-e e 146acitc alb O ( ciz 7(00 Fu-t-- ak\J((P , WA REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC DEC 1 7 2007 D NfTu Tukwila D ION FILE COPY INCOMPLETE LTR# t1,141-9-1 ilexantler'sfleciric, Inc. Commercial Industrial Residential 18342 Redmond Fall City Rd Redmond, WA 98052 Ph. (425) 869 -7170; Fax (425) 869 -7303 alexandersel@verizon.ne Project Name: Family Fun Center Headquarters Unit 100 Panel schedule: 200 amps 120/208 volt, 3 ph 1 HVAC roof top 30 A 2 Lights (Reception) 20A 3 (4 " " - -- 4 Lights (Offices) 20 A Si -- " - - - " - -- 6 Lights (Confer. room) 20 A 5 7 Outlets (Rooms 103,104) 20 A 8 Refrigerator 20 A 9 Outlets (Rooms 101, 105) 20 A 10 Insta -hot 20 A 11 Outlets (Rooms 105, 106) 20 A 12 Kitchen 20 A 13 Restroom 20 A 14 Spare 20 A 15 CPU 20 A 16 Spare 20 A FILE COPY INCOMP .ETE CITY OF TUIMIILA LTR# utU 12 2007 PERMIT CENT ER 1 1°QA Commercial Industrial Residential 18342 Redmond Fall City Rd Redmond WA 98052 Ph. (425) 869 - 7170; Fax (425) 869 -7303 alexanderseJa verizon.net Project Name: Family Fun Center headquarters General lighting: 3.5VA/sq. ft x 1,221 sq. ft = Small Appliance: 2 x 3 kVA = Water Heater: 1 x 1.5 kVA = Microwave: 1 x 1.5 kVA = Disposal (1/2 hp): 1 x 1.2 kVA= Largest motor: 1 x 1.2 kVA = HVAC:1xio kVA = Convenient outlets: 32 x 18o kVA = Total: Total Amps at 120/208 volt 3 phase: A /exander'sElectric, /nc, Load Calculation 4.3 kVA 6 kVA 1.5 kVA 1.5 kVA 1.2 kVA 1.2 kVA 10 kVA 5.8 kVA 31.5 kVA 87.5 Amps FILE COPY December 6, 2007 Alex Korolenlco 18342 Redmond Wy Redmond WA 98052 RE: Letter of Incomplete Application # 1 Electrical Permit Application EL07 -734 Family Fun Center Headquarters — 7100 Fun Center Wy Dear Mr. Korolenlco, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on _ December 3, 2007 is determined to be incomplete. Before your application can continue the plan review process the following item from the following department needs to be addressed: Building Department: Bill Buterbaugh, at 206 973 -4758, if you have any questions concerning the following comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that three (3) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, ifer M. shall it Technician Enclosures File: EL07 -734 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director P:\Permit Center\Incomplete Letters\2007\EL07 -734 Incomplete Ltr #1.DOC Jem 1. Provide one line diagram and panel schedules. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: ELO7 -731 DATE: 12 -12 -07 PROJECT NAME: FAMILY FUN CENER WOLD HDQRTS SITE ADDRESS: 7100 FUN CENTER WY Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: P t*n J Bui'c"ifig uwision Public Works n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Please Route TUES/THURS ROUTING: Documents/routing slip.doc 2 -28 -02 REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required ❑ DUE DATE: 1 2-1 3-07 Not Applicable E No further Review Required DATE: DATE: Planning Division Permit Coordinator n n DUE DATE: 01-10-08 Approved n Approved with Conditions I V I Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL07 - 734 DATE: 12 -03 -07 PROJECT NAME: FAMILY FUN CENTER WORLD HDQTRS SITE ADDRESS: 7100 FUN CENTER WY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: ned ang t h an Public Works Comments: n Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: `il a,t i LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials:: TUESITHURS ROUTING: Please Route ❑ Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY ❑ Planning Division C Permit Coordinator n DUE DATE: 12-04 -07 Not Applicable ❑ No further Review Required DATE: DATE: n DUE DATE: 01-01-08 Approved n Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Project Address: Contact Person: 1 '7, 1 p - l oek City of Tukwila Sheet Number(s): "Cloud" or highlight all areas of revision including date o Received at the City of Tukwila Permit Center by: Entered in Permits Plus on G \applications\ orm s- applications on line\revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 981 S8 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Plan Check/Permit Number: EL07 -734 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Family Fun Center World Headquarters Phone Number: revision Steven M Mullet, Mayor Steve Lancaster, Director CITY RECEIVED UKWILA DEC 12 2007 PERMIT CENTER Summary of Revision: License Information License ALEXAEI964L9 Licensee Name ALEXANDER'S ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 602343709 Verify Workers Comp Premium Status Ind. Ins. Account Id 4743001 Business Type CORPORATION Address 1 18342 REDMOND FALL CITY RD Address 2 City REDMOND County KING State WA Zip 98052 Phone 2069315588 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 6/29/2004 Expiration Date 6/29/2008 Suspend Date Separation Date Parent Company Previous License ALEXAE *980L7 Next License Associated License KRATMA *980C1 Look Up a Contractor, Electrician or Plumber License Detail bora id:: Printer Friendly Version Look Up a Contractor, Electrician or Plumber Topic Index 1 Contact Info search Safety (- r Claims & Insurance Workplace Rights Trades & Licensing Find a Law or Rule Get a Form or Publication Electrical Contractor A business licensed by L£tl to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. rage 1 or https: // fortress. wa. gov /lni/bbip/Detail.aspx ?License= ALEXAEI964L9 12/19/2007 GENERAL CONSTRUCTION NOTES 1. This set represents "the construction drawings" and is intended to show minimum requirements. It is the responsibility of the contractor to provide all construction necessary for the complete installation of all operating systems, materials and finishes in accordance with mfr.'s recommendation. Contractor shall thoroughly review drawings, specifications and owner's requirements. 2. Contractor shall field verify all existing dimensions prior tc bid. Discrepancies in dimensions, drawings, graphic representation and actual field measurements shall be brought to the immediate attention of the designer. 3. Construction shall be based on the city's approved plans and owner's comments. The approved plans are to remain on site at all times for use by all involved trades and inspectors. 4. These documents are prepared for the use by contractor and in no way, either in whole or in part constitute any direction or instruction to any contractor with regard to construction methods, means or techniques. 5. Contractor shall be responsible for demolition work including, but not limited to, sequence & temporary shoring of all existing structures & verification of existing utilities & services. 6. Contractor shall notify utilities prior to commencement of all work. The contractor is responsible for repairs, subject to city and utility inspector's final approval. 7. Contractor shall clean up all public right -of -way and private driveways after each work day. Construction vehicles shall not block public traffic or entries at any time. Contractor shall work according to city's allowed schedules only. 8. All items shown or specified on these plans to be provided and installed by the General Contractor or appropriate Subcontractor unless otherwise noted. 9. New construction shall conform to International Building Code 2003 Edition, minimum requirements for Type VB- sprinklered, throughout a B occupancy. 10. General Contractor to remove exisiting window blinds prior to demolition, and re- install cleaned window treatments after all work completed. 11. General Contractor to clean entire tenant improvement, including interior face of exterior windows, after all sub - contractors are completed and prior to the owner's move -in. 12. All trades working in plenum must meet all applicable codes. 13. Design of new or relocation of HVAC by subcontractor. Insulate mechanical supply ducts with batting or duct board. 14. Provide smoke detectors to code. Provide fire extinguishers to code and locate as per plan if designated or contact Designer for approval of location. Paint recessed metal cabinets to match walls. 15. Insulate all walls with sound attenuation batting as per plan. 16. Height differences between flooring materials shall bevel at a ratio of 1:2 if greater than 1/4" per ADA accessibility codes. 17. Plumbing walls with toilet drains, interior Mechanical Room walls, and walls with Pocket Doors are 2X6 construction. 18. General Contractor to contact telephone, computer, sound and communication system or other involved parties, when walls are open to receive wiring. 19. Equipment Supplier, General Contractor and Subcontractors shall coordinate exact locations and specific requirements for th equipment installation. Provide templates for .. locations of all stub -outs and blocking points fo the equipment, if necessary. General Contractor to coordinate and is responsible for proper installation of all equipment. 20. Any items or surfaces which are unspecified as to material and or color are to be brought to the Designer's attention for specification. 21. Cabinetmaker to verify field dimensions for all fabrications. 22. Contractor to provide backing / blocking for all wall hung cabinets, towel bars, and coat hooks as required. Contractor to provide in -wall brackets for unsupported countertops, attached to framing. Verify locations, gauge , height and weight requirements with cabinetmaker. When other type of suports are to be used, verify style w/ Designer. 23. General wall finish to be smooth, level 4, plus fist coat (prime coat). Areas with high sun exposure to be level 5. 44 Eo T 5-4" VIC 2' -0" \ITY NOT TO SCALE 16'-8" 24' -2" V AP i 16'-8" 25' -0° 9' 0" 6'- 101/2' BUL3\G PLOOR PLA\ 25' -0" 10' -0" I\TERIOR DESLAER officewraps, inc. LORI SALEBA, DESIGNER YUKO MATSUURA, DESIGNER 570 KIRKLAND WAY SUITE 201 KIRKLAND, WA 98033 (425) 952 -5393 FAX (425) 952 -5397 EMAIL: Iori©officewraps.com yuko®officewraps.com CO \TRACTOR AXIOM COMMERCIAL CORP __ NICK GALLASH 13110 N.E. 117TH PL SUITE 312 WOODINVILLE, WA 98072 (206)335 -2770 LIC #: AXIOMCC997NH EMAIL: nick©axiomcommercialcorp.com BULDI \G OW FAMILY FUN CENTERS SCOTT HUISH 7300 FUN CENTER WAY TUKWILA, WA 98188 (503) 381 -9590 EMAIL: huwish@aoll.com ER 3'-6' O 24' -2" 7 Fo O 0 • w C REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. '.r Revisions will require a new plan submittal T:,,,- include additional plan review fees. FILE COPY : Permit No, 6 Pier review approval Is subject to ewers end omissions. Approval of c onsauctian documents does not eultiodze the violation of any adopted code or ordinance. Receipt of approved Retd • yk . and Is admowledged: B Y e /9z67) cOPPEP. Date: 2 / J6 City of / Tukwila Rt�IWIN( DMSVONI REVISION LIST NUMBER DATE SHEET NOTE SCOPE OF VPROVEVENTS: CONSTRUCT TENANT IMPROVEMENTS FOR A 1,221 S.F. OFFICE, INCLUDING INTERIOR PARTITIONS, FINISHES, PLUMBING, ELECTRICAL WIRING AND LIGHTING. F P U RE SPRMLER SYSTEV, LUVBI\G & -VAC TO BE \�ER SEPARATE PERvT vIEC V A OFE_, CAL DRAWING INDEX: A - 1.0 BUILDING FLOOR PLAN VICINITY MAP PROJECT DATA GENERAL CONSTRUCTION NOTES CONTACT INFO SHEET INDEX A -2.0 FLOOR PLAN WALL LEGEND DOOR / HARDWARE SCHEDULE DOOR & DOOR FRAME TYPES TYPICAL INTERIOR WALL SECTIONS GENERAL CABINETRY NOTES A - 3.0 RCP / LIGHTING PLAN RCP LEGEND RCP GENERAL NOTES CEILING DETAILS A - 4.0 ELECTRICAL PLAN ELECTRICAL LEGEND / ABBREVIATION ELECTRICAL / PLUMBING NOTES PLUMBING SCHEDULE MISC. ACCESSORIES / HARDWARE SCHEDULE A -5.0 FINISH PLAN INTERIOR ELEVATIONS FINISH SCHEDULE PLASTIC LAMINATE SCHEDULE FLOOR TRANSITION DETAILS PROJECT DATA: STREET ADDRESS FAMILY FUN CENTER WORLD HEADQUARTERS SCOTT HUISH 7100 FUN CENTER WAY TUKWILA, WA LEGAL DESCRIPTIO v 242304 92 PORTION OF W OF SECTION 24 -23 -04 BEGIN INTERSECTION OF 2M LINE OF PRIMARY STATE HIGHWAY NO 1, GREEN RIVER INTERCHANGE UNDER KC SUPERIOR COURT CAUSE NO 596089 STA POC (2M) 134 +28.56 WITH A -LINE STA POT (A) 102 +82.12 WITH STATE OF WASHINGTON DEPT OF TRANSPORTATION SR 405 GREEN RIVER INTERCHANGE R/W STA 99 +00 TO STA 120 +00 SHEET 2 OF 2 REVISED DECEMBER 31, 1992 TH N 42 -30 -02 E ALONG CA OF SAID A -LINE 88.55 FT TO STA 103 +70.67 OF SAID A -LINE TH N 47-29-58 W 60 FT TO POINT ON NLY R/W OF SAID PRIMARY STATE HIGHWAY NO 1 SAID POINT BEING BEGINNING OF CURVE CONCAVE TO SOUTH RADIUS OF 163 FT AND ALSO BEING POINT OF BEGINING TH NLY, ELY & SLY ALONG SAID R/W ON ARC OF SAID CURVE THRU C/A 0 64-48-29 184.37 FT TH LEAVING SAID R/W & BEARING N 21 -14 -41 E 38.16 FT TH N 64 -48 -08 W 5.90 FT TH N 22 -58 -18 W 166.10 FT TH N 22 -01 -42 E 229.49 FT TO POINT ON ORDINARY HIGH WATER LINE OF GREEN (WHITE) RIVER AS APPEARED ON AUGUST 11, 1997 TH ALONG ORDINARY HIGH WATER OF SAID RIVER THE FOLLOWING COURSES AND DISTANCES S 70 -00 -00 W 39.06 FT TH S 73 -00 -00 W 65 FT TH 5 67 -00 -00 W 100FT TH S 57 -40 -00 W 30 FT TH 63 -50 -00 W 35 FT TH S 56 -30 -00 W 100 FT TH S 51 -00 -00 W 50 FT TH S 35 -40 -00 W 40 FT TH S 39-00-00 W 60 FT TH S 52-20-00 W 50 FT TO NELY R/W FOR 2M-LINE TH SLY ALONG R/W TO ITS INTERSECTION WITH NLY R/W OF SAID A -LINE TH N 42 -30 -02 E 9.42 FT TO POINT OF BEGINING -AKA ADJUSTED PARCEL 1 OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L98 -0028 RECORDING NO 9806309017 ASSESSOR'S PARCEL \ U V B -R: 242304909201 SITE (Sc LOT COVERAGE TOTAL SITE AREA: N/A IMPERVIOUS AREA: N/A BUILDING ENVELOPE AREA: N/A LOT COVERAGE: N/A TI/ BUL\C STATISTICS NUMBER OF STORIES : 1 OCCUPANCY CLASSIFICATION : B- BUSINESS OCCUPANCY LOAD :13 (1,221 SF / 100 SF = 13 OCCUPANTS) NUMBER OF EXIT REQUIRED : 1 NUMBER OF EXIT PROVIDED : 1 BUILDING TYPE: TYPE -V -B SPRIBKLERED AREA OF SPACE TO BE REMODELED: 1 jE �� - FOR CONSTRUCTION VALUE: $ 36,630.00 CODECOt''�P NFPA 70 -NEC PAR<\C I\F0RvAT10 oEc „ Z;m STANDARD -73 COMPACT - 5 ACCESSIBLE -4 ZO\I\G I\F0RvAT10 JURISDICTION: CITY OF TUKWILA, WA ZONING : CITY OF TUKWILA, WASHINGTON 98188 ZONING DESIGNATION CAI-COMMERCIAL LIGHT INDUSTORIES SETBACK REQUIREMENTS: N/A BUILDING HEIGHT PERMITTED: N/A PROPOSED BUILDING HEIGHT: N/A TRANSPORTATION MANAGEMENT PLAN NOT REQUIRED CODE COVPLA\CE I \FORvAT10\ BUILDING C0DE:2003 INTERNATIONAL BUILDING CODES 2003 WA STATE ENERGY CODE AMERICAN NATIONAL STANDARD - ANSI A117.1 -2003 6"ir ARw.... err; r : Ti 1 14'SNf1_i Put& Works, Bolding won PERMIT NUMBER DEC 0 3 2007 ANY 07 7 '!_'; ii'vil -- :N•i eta 4 t4iffl This set of drawings shall not be copied in whole or in part without prior written consent from the owner. This document is considered as one unit and shall not be considered complete of whole if documents are separated in any manner. Documents shall not be separated for the purpose of submitting proposals or for separate phases of construction. (0 W ct 0 0 w 0 J 0 OC W W 0 z LL J 0 0 J CO 1- W oc 1-- z LL DATE: 10/1 5/2007 REVISIONS BY: A 1.0 OF: 5 SCALE: AS NOTED SHEET: CONSTRUCTION SET FILE COPY GENERAL CABINETRY NOTES Shop drawings are required for approval before fabrication, and should be drawn using actual field measurements. Any substitutions to these specifications should be approved by the Designer before proceeding. 1. Casework construction: AWI Custom grade white low- pressure laminate over 3/4" Industrial board. 2. All shelving to be adjustable. Exposed shelving and exposed cabinet box interiors to be high pressure laminate. 3. Drawers: White low- pressure laminate bonded over 3/4" industrial board. All file drawers will need to be constructed to receive the pendaflex hangers without a separate rack and need to be letter size hanging front to back unless otherwise noted. 4. Drawer slides: Full extension, 100Ib rating zinc finish- Accuride #3832. Full extension, 150Ib rating zinc finish- Accuride #4034 on all file drawers. Blum 125 degree self - closing hinges or equal. 5. Countertops: Plastic laminate bonded over 3/4" industrial board unless otherwise noted. 6. Self- edges: Plastic laminate unless otherwise noted. Other edges such as wood or stone when specified will have a detail provided or check with designer. 7. Locks to be included where specified on elevations. Finish to match pulls or verify with Designer. 8. Electrical grommets: Included on all desk - height surfaces in kneeholes. Power, phone and computer jacks will be installed 18" AFF in kneeholes and cords brought through grommets. Verify color of grommets with designer. Final placement of grommets to be determined by tenant and drilled on -site. 9. Plastic laminates are specifed from Pionite, Wilsonart, Nevamar, Laminart or Formica. See Plastic Laminate schedule for manufacturer and color. If unclear on specification for any surface, call Designer. 10. Interior finished dimensions of upper cabinets should be 12" clear minimum, unless noted otherwise. 21. Undercabinet lighting to be mounted behind valence at front of upper cabinet. Sides of upper cabinet boxes must not extend below cabinet bottom to allow for installation of this lighting. 12. Trash management grommets where specified to be placed in the counter as shown on the Interior Finish Plan. Refer to Misc Hardware Schedule for style and finish. 13. Provide keyboard arm with sliding mouse tray where indicated on plans. Submit brand specification and verify with designer before installation. 14. Backsplashes to be 3/4" x 4" wrapped with plastic laminate unless otherwise noted. Check elevations, if full backsplashes to the underside of the upper cabinets are called out they are to be 3/4" thick. 15. Check desk height surfaces for backsplashes. If backsplash is not specified, scribe surface for tight fit to wall. 16. Doors and drawer heads to be plastic laminate with white low - pressure cabinet liner, banded with plastic laminate. 17. Pulls are to meet barrier free codes. Style and finish called out on Misc Hardware Schedule. 18. Provide Marine Grade Plywood for cabinets above and around sterilizers where indicated in Labs or Sterilization. Do not place seams in laminate under sterilizers to avoid delamination from moisture and heat. 19. Refer to Misc Hardware Schedule for dispenser specifications where applicable. 20. Where applicable, cabinetmaker to verify chart size with Client / Doctor to determine chart rack dimensions. Horizontal sections not to exceed 2' -6" to prevent sagging. Vertical wire dividers to be installed front to back at equal intervals of not more than 12" for chart support. DOOR SCHEDULE LOCATION SPECIFICATION FRAME GROUP REMARKS NO. SIZCOR TYPE MAIN ENTRANCE 1 EXISTING DO EXISTING LOCKSET DOOR CLOSER NOTED AS: "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" RESTROOM 2 1 3/4" x 3' -0" x 7 -0" U FLUSH 0 PRIVACY DOOR CLOSER, WALL STOP, COLOR: T.B.D. CONFERENCE 3 1 3/4" x 3' -0" x 7-0" CO 0 LATCHSET WALL STOP, GLASS DESIGN: T.B.D. OFFICE 1 4- 1 3/4 x 3' -0" x 7' -0" (O LOCKSET WALL STOP, GLASS DESIGN: T.B.D. OFFICE 2 5 1 3/4' x 3'-O" x 7--O" Q tO LOCKSET WALL STOP, GLASS DESIGN: T.B.D. OFFICE 3 6 1 3/4" x 3' -O' x 7' -0" OA Q LOCKSET WALL STOP, GLASS DESIGN: T.B.D. DOOR NOTES: 1. SUBMIT KEYING SCHEDULE AND HARDWARE SAMPLES FOR APPROVAL. HDWR TO MATCH EXISTING. 2. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 3. HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS, CABINETS, PLUMBING FIXTURES AND STORAGE FACILITIES SHALL HAVE A LEVER OR OTHER SHAPE WHICH WILL PERMIT OPERATION BY WRIST OR ARM PRESSURE AND WHICH DOES NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING TO OPERATE. 4. DOOR THRESHOLD SHALL NOT EXCEED 1/2" IN HEIGHT. 5. MAX. DOOR OPENING PRESSURES ARE LIMITED TO 8.5 LBS. AT EXTERIOR DOORS AND 5.0 LBS. AT INTERIOR DOORS. 8. VERIFY ALL DOOR SWINGS, HARDWARE AND KEYING REQUIREMENTS. 7. NEW DOORS AND FRAMES: FINISH T.B.D. 8. EXISTING DOORS AND FRAMES TO BE CLEANED AND REFINISHED. 9. ALL DOOR FRAMES TO BE CUSTOM GRADE. 10. NEW DOOR TRIM TO BE 2 -3/4 X 3/4' WITH EASED EDGE, UNLESS OTHERWISE SPECIFIED. 11. ACCESSIBLE RESTROOM SIGNAGE W/ TACTILE CHARACTOR TO BE LOCATED ON PUSH SIDE OF DOOR W/ CLOSERS AND WITHOUT HOLD -OPEN DEVICE TACTILE CHARACTOR SHALL BE 48 INCH MIN., 60 INCH MAX ABOVE FLOOR. DOOR HARDWARE TYPE OF LOCK SPECIFICATION Passageway SCHLAGE: AL Series Lever: NEPTUNE Finish: #626 Satin Chromium Plated Privacy (Restroom) SCHLAGE: AL Series Lever: NEPTUNE Finish: #626 Satin Chromium Plated 11INCH (280mm) MAXIMUM REACH HEIGHT NOTES: 1. Provide standard weight commercial door hinges 2. All doors with closers to have ball bearing hinges 3. Provide door stops at appropriate locations 4. Wood doors & frames to receive 1 coat of benite prior to stain and lacquer. Stain color to match wood veneer (provide sample for designer's approval) 5. Door hardware finish: Oil Rubbed Bronze 6. Alternate Manufacturers may be selected with designer's approval TABLE 606.7 ICC / ANSI A-117.1-2003 MAXIMUM REACH DEPTH AND HEIGHT MAXIMUM REACH DEPTH .5 INCH (13mm) 2 INCH (50mm) 5 INCH (125mm) 6 INCH (150mm) 9INCH (230mm) 11INCH (280mm) MAXIMUM REACH HEIGHT 48 INCH (1220mm) 46 INCH (1170mm) 42 INCH (1065mm) 40 INCH (1050mm) 36 INCH (915mm) 34 INCH (865mm) UTILITIES 0) E (I571NG PLUMBING CONFERENCE MEN r 0 0 0 11 T Ir • • 111 Awe 1u J■r 111 aw• 111 rr IN • I ■r 1• ■■r IN ■r 1■ ANY I■ IP m NMI 1■ lii IO AEI 111 AMP" Iu /•• 1■ � .r r iu 1 iu \ II: . o / ii Air � 411 ; AEI OFFICE 1 ; • L 104 I i n Iu / m • / ii . • ■■. I m i1 1■ I/ iw u 1 12' -1 12 I 11 11 u i 11 I■ N ' 1 11 11■ • • • • • I v • 111 • • i i iu �I 1■ 111 tr • . l 1 • 11 i 11 • a iu IF 1■ 11 • • • ■ ■ • ••• / 1• I! 1■ 111 Iu 1u II 1 1� ILI I1"1 Iu Iu I■ IN IN IA Ir 1■ Ir 1■ I■ 1■ In lu 1■ I■ IN 1■ in I■ IL 1■ 1■ 111 w Iu IN 1r I■ IN IU Iu Ilt 1■ u J!! ■r■u OFFICE 2 UTILITIES RECEPTION [V ;4" N ti M in EN N f 41 -211 3' -0" 17' -10" 1 le 6' -7" I 10' -1 112'I • r Iw FLOOR PLAN SCALE: 1 /4 " =1 '-0" 24' -2" 23 -9" = r M to WALL LEGEND NEW PARTITION WALL o"o"o o` "o" 0000( WALL W /BLOCKING 11010 ■•01�■■■■1•=.�1 , rri DEMISING /SOUND WALL EXISTING WALL NO SCALE 5/5' G.W.B. ON 3.5' MET. STUDS 0 16' O.C. W/ RG CHANNEL Or O.C.) & SOUND ATTENUATION BLANKET (•) 0 DEMISING WALL TYP. BETWEEN TENANT SPACES TYP. INT. PARTITIONS INSTALLATION NOTES: 5/B' G.W.B. ON 3.5' HET. STUDS 0 24 C.C. NON -RATED WALL USE DEFLECTION TRACKS ® TOP OF PARTITIONS TO STRUCTURAL SUPPORTS ABOVE TYPICAL INTERIOR WALL SECTIONS - CHD. DIM- 1 4" 1 -LITE W/ TOP -LITE TEMPERED GLASS NOT TO SCALE � 4 39-41 54 min 12 42 min S1de WaII 1 4" 1 -LITE TEMPERED GLASS DOOR TYPES FRAME TYPES WHEELCHAIR TURNING SPACE CLEAR FLOOR SPACE CP W/C NOT TO SCALE NOT TO SCALE CD co GRAB BARS © W/C NOT TO SCALE HD. DI HD. DI 0 1 4" SOLID WD. FLUSH DOOR E C9 Lr) NOT TO SCALE 3G min ---- 13 13 13- min clear floor spa J GO min STORE DOOR TEMPERED GLASS 2 3/4" l" PLOUGH 41/2" DOOR TRIM -,1-1/2"1- CUSTOM WOOD NOT TO SCALE DOOR OPENING EASED EDGE RT1- RADIUS TO BE PLACED AT OUTSIDE EDGE OF DOOR OPENING ELom 734 RECEIVED er,/inc 71 "(WILA DEC 0 3 2007 b ALAI i I�iNTI� This set of drawings shall not be copied in whole or in part without prior written consent from the owner. This document is considered as one unit and shall not be considered complete of whole if documents are separated in any manner. Documents shall not be separated for the purpose of submitting proposals or for separate phases of construction. 0 Z 0 J co LLI LU L.L. irr C U-I LL LL DATE: 10/15/2007 REVISIONS BY: SCALE: AS NOTED SHEET: CONSTRUCTION SET A 2.0 OF: 5 RCP LEGEND CEILING LEGEND WALL SWITCH ( +48 ") -tom 2'X 4' GRID @ 10' -0" A.F.F. WALL SWITCH W/ MOTION SENSOR ( +48 ") ( QVS2GPFOS332 ' "LIGHTOLIER" 2'X4' -3 LAMP 5i "DEEP MICROPERFORATED MESH LAMP, (3) T8 TRIM KIT: "LITHONIA" DGA 24 INDICATE 24 HOUR FIXTURE UNDERCABINET FLUORESCENT STRIP — - = "JUNO" CH6- 213Q- 650C -WH W /35K LAMPS W/ HB -26 HANGER BARS ® VIBIA - #0356 -01 (1) TULIP HANGING LAMPS POLISHED CHROME METAL FINISH. MATTE OPAL BLOWN GLASS DIFFUSER VERIFY EXACT LOCATION & HEIGHT W/ DESIGNER (RECEPTION) W VIBIA - #0361 -01 (1) TULIP WALL LAMP POLISHED CHROME METAL FINISH. MATTE OPAL BLOWN GLASS DIFFUSER SEE ELEVATION FOR EXACT LOCATION (RESTROOM) "WAC" (3) HR -837 3" LOW VOLTAGE ROUND MINIATURE DIRECTIONAL SPOT FINISH: BN- BRUSHED NICKEL PROVIDE NECESSARY LAMP / HOUSING (CONFERENCE) �o "SEAGULL LIGHTING" (3) #9485 -298 AMBIENCE ACCENT DISK FINISH: EUROTECH (CONFERENCE) L "LIGHTOLIER" EDGE -LIT EXIT SIGN EX- SERIES / RECESSED MOUNT =� 7 i + + -0.2.00 BROAN EXHAUST FAN / L100 - 100 CFM EXHAUST THRU ROOF "LITHONIA "AFFINITY EMERGENCY LIGHTS W/ BATTERY 9 Q FINISH:t(ICKEL P/2ov/M foal cliA Ipt- lui 11A!rlto I"' ft et /»L -evM iIVr7/1 O'Glais Plint logy /9Nb TF/L /G/L 1 1.= 111 0, 1111.1 1 RE . 6' 10° 101 PTION + + f + + + + + + + F .+ + + + + + + + + ; + +� + + + + + + - + + + + + i /\ ONFERENCE + + + + + + - ± T + 8 + + +� + + + T + + + + + T T + + + + . + + Ty + + + + ▪ + +.+ + �T T • + T ++ + T + + + - + + + T + + + + + ;n n Q RCP / SIGHT SCALE: 1 /4 " =1' -0" \G PLAN 10' 1 1/2 ltC 3 3 1 2 NOT TO SCALE EXISTING ROOF STRUCTURE 11II1IMIMIIIIIIIIIIIMIII■. CEILING EDGE TRIM ACOUSTICAL CEILING TILES IN SUSPENDED T BAR GRID SYSTEM t PER RCP PER RCP %' TYPE 'X' GYP. BOON METAL FRAMING SYSTEM TYP. SOFFIT DETAIL 0 U OC ce a. RCP GEN. NOTES 1. PROVIDE AND INSTALL EMERGENCY EXIT SIGNS, HORNS, AND EMERGENCY LIGHTING AS PER CODE. VERIFY LOCATION WITH DESIGNER. 2. PROVIDE AND INSTALL NEW 2 X 4 GRID WITH ACCOUSTICAL PANELS TO BE ARMSTRONG / DUNE. 3. CONTRACTOR TO FURNISH AND INSTALL ` UNDERCABINET LIGHTING AS SHOWN ON RCP. FIELD VERIFY LOCATIONS AND SIZE WITH DESIGNER. 4. DESIGNER IS NOT RESPONSIBLE FOR VENTILATION REQUIREMENT OF MEDICAL EQUIPMENT. VERIFY VENTILATION REQ WITH DOCTOR AND EQUIPMENT SPECIALIST WHEN APPLICABLE. 5. PENDANTS TO BE FIELD LOCATED. VERIFY DROP HEIGHT AND LOCATION W/ DESIGNER BEFORE INSTALLATION. 6. SUBMIT LIGHTING SCHEDULE TO DESIGNER FOR APPROVAL. 7. FIRE REQUIREMENTS UNDER SEPARATE PERMIT. PROVIDE AND INSTALL ALL NECESSARY FIRE REQUIREMENTS PER CODE. (INCLUDING FIRE EXTINGUISHER) 8. VERIFY LEAD TIMES FOR LIGHTING AS SOME PRODUCTS MAY HAVE EXTENDED LEAD TIME. \ \ S NP7 ROOF STRU 45' MAX. 12 GA. TENSION WIRES (TYP.) 31/2°W 20 GAUGE METAL STUDS @ 6' -0° O.C. TYP., FASTEN TO TOP OF WALL & EXIST. CONST. WI 2 - #10 GA. SCREWS RUNNER CHANNEL HEAVY DUTY MAIN RUNNERS @ 48" O.C.. TYP. 2' BERG CLIPS WITH 7I8° ARMSTRONG WALL MOLDING ( #7800) (SEE ARMSTRONG SEISMIC INSTALLATION INSTRUCTIONS) 5 /8' TYPE °X° GYP. BD. EACH SIDE 7 ,---- WITH 3 5/89° x 25 GA. METAL STUDS @ 24° 0. FASTEN BOT. OF STUDS TO FRAMING W/ 2 - #10 GA. SCREWS @ 4' -0' O.C. WOOD OR RUBBER BASE SEE FINISH SCHEDULE RUNNER CHANNELTh ( FINISH SEE FINISH SCHEDULE CEILING SEISMIC REINF. DETAIL NOT TO SCALE TYP. ROOF STRUCT: 3/4° DIA. CONDUIT TENSION WIRE & SLEEVE SLEEVE W12- # 10 GA. SCREWS TYPICAL ACOUSTICAL CEILING: PROVIDE SEISMIC REINFORCING PER 2003 IBC AND CISCA GUIDELINES FOR SEISMIC ZONES 3-4 SEISMIC STRUCTS @ 12-0' EA. WAY, BRACED WI 4 -12 GA. WIRE PER STRUT INSTALL PERIMETER WIRE AT ALL T -BARS PROVIDE 2 -12 GA LIGHT WIRES PER LIGHT FIXTURE (TYP.) R Q NFPA 70 1 7 2111 City Of Tukwila I B ILDXN NISI ©�1 ELo7 73'1 RECEIVED r n ' r r 'I<WIt DEC 0 3 2001 °�tia'v11 N T EIS This set of drawings shall not be copied in whole or in part without prior written consent from the owner. This document is considered as one unit and shall not be considered complete of whole if documents are separated in any manner. Documents shall not be separated for the purpose of submitting proposals or for separate phases of construction. 0 vi W W U U- 0 a) 0 c LL CD Z 0 J m J LL! w F-- Z W 0 z LL LL DATE: 10/15/2007 REVISIONS BY: A 3.0 OF: 5 SCALE: AS NOTED SHEET: CONSTRUCTION SET CEILING LEGEND 2'X 4' GRID @ 10' -0" A.F.F. GWB CEILING @ 10' -0" A.F.F. (P -2) GWB CEILING @9- 6 "A.F.F. (P-2) 7 i + + + � t + + ± � + . + + + + +T + +T- GWB CEILING @ 9 -0" A.F.F. P/2ov/M foal cliA Ipt- lui 11A!rlto I"' ft et /»L -evM iIVr7/1 O'Glais Plint logy /9Nb TF/L /G/L 1 1.= 111 0, 1111.1 1 RE . 6' 10° 101 PTION + + f + + + + + + + F .+ + + + + + + + + ; + +� + + + + + + - + + + + + i /\ ONFERENCE + + + + + + - ± T + 8 + + +� + + + T + + + + + T T + + + + . + + Ty + + + + ▪ + +.+ + �T T • + T ++ + T + + + - + + + T + + + + + ;n n Q RCP / SIGHT SCALE: 1 /4 " =1' -0" \G PLAN 10' 1 1/2 ltC 3 3 1 2 NOT TO SCALE EXISTING ROOF STRUCTURE 11II1IMIMIIIIIIIIIIIMIII■. CEILING EDGE TRIM ACOUSTICAL CEILING TILES IN SUSPENDED T BAR GRID SYSTEM t PER RCP PER RCP %' TYPE 'X' GYP. BOON METAL FRAMING SYSTEM TYP. SOFFIT DETAIL 0 U OC ce a. RCP GEN. NOTES 1. PROVIDE AND INSTALL EMERGENCY EXIT SIGNS, HORNS, AND EMERGENCY LIGHTING AS PER CODE. VERIFY LOCATION WITH DESIGNER. 2. PROVIDE AND INSTALL NEW 2 X 4 GRID WITH ACCOUSTICAL PANELS TO BE ARMSTRONG / DUNE. 3. CONTRACTOR TO FURNISH AND INSTALL ` UNDERCABINET LIGHTING AS SHOWN ON RCP. FIELD VERIFY LOCATIONS AND SIZE WITH DESIGNER. 4. DESIGNER IS NOT RESPONSIBLE FOR VENTILATION REQUIREMENT OF MEDICAL EQUIPMENT. VERIFY VENTILATION REQ WITH DOCTOR AND EQUIPMENT SPECIALIST WHEN APPLICABLE. 5. PENDANTS TO BE FIELD LOCATED. VERIFY DROP HEIGHT AND LOCATION W/ DESIGNER BEFORE INSTALLATION. 6. SUBMIT LIGHTING SCHEDULE TO DESIGNER FOR APPROVAL. 7. FIRE REQUIREMENTS UNDER SEPARATE PERMIT. PROVIDE AND INSTALL ALL NECESSARY FIRE REQUIREMENTS PER CODE. (INCLUDING FIRE EXTINGUISHER) 8. VERIFY LEAD TIMES FOR LIGHTING AS SOME PRODUCTS MAY HAVE EXTENDED LEAD TIME. \ \ S NP7 ROOF STRU 45' MAX. 12 GA. TENSION WIRES (TYP.) 31/2°W 20 GAUGE METAL STUDS @ 6' -0° O.C. TYP., FASTEN TO TOP OF WALL & EXIST. CONST. WI 2 - #10 GA. SCREWS RUNNER CHANNEL HEAVY DUTY MAIN RUNNERS @ 48" O.C.. TYP. 2' BERG CLIPS WITH 7I8° ARMSTRONG WALL MOLDING ( #7800) (SEE ARMSTRONG SEISMIC INSTALLATION INSTRUCTIONS) 5 /8' TYPE °X° GYP. BD. EACH SIDE 7 ,---- WITH 3 5/89° x 25 GA. METAL STUDS @ 24° 0. FASTEN BOT. OF STUDS TO FRAMING W/ 2 - #10 GA. SCREWS @ 4' -0' O.C. WOOD OR RUBBER BASE SEE FINISH SCHEDULE RUNNER CHANNELTh ( FINISH SEE FINISH SCHEDULE CEILING SEISMIC REINF. DETAIL NOT TO SCALE TYP. ROOF STRUCT: 3/4° DIA. CONDUIT TENSION WIRE & SLEEVE SLEEVE W12- # 10 GA. SCREWS TYPICAL ACOUSTICAL CEILING: PROVIDE SEISMIC REINFORCING PER 2003 IBC AND CISCA GUIDELINES FOR SEISMIC ZONES 3-4 SEISMIC STRUCTS @ 12-0' EA. WAY, BRACED WI 4 -12 GA. WIRE PER STRUT INSTALL PERIMETER WIRE AT ALL T -BARS PROVIDE 2 -12 GA LIGHT WIRES PER LIGHT FIXTURE (TYP.) R Q NFPA 70 1 7 2111 City Of Tukwila I B ILDXN NISI ©�1 ELo7 73'1 RECEIVED r n ' r r 'I<WIt DEC 0 3 2001 °�tia'v11 N T EIS This set of drawings shall not be copied in whole or in part without prior written consent from the owner. This document is considered as one unit and shall not be considered complete of whole if documents are separated in any manner. Documents shall not be separated for the purpose of submitting proposals or for separate phases of construction. 0 vi W W U U- 0 a) 0 c LL CD Z 0 J m J LL! w F-- Z W 0 z LL LL DATE: 10/15/2007 REVISIONS BY: A 3.0 OF: 5 SCALE: AS NOTED SHEET: CONSTRUCTION SET PLUMBING SCHEDULE QTY ITEM LOCATION SPECIFICATION FIXTURES / FITTINGS 1 Sink Restroom #102 "Kohler" K- 2606 -S Samba Self- rimming lavatory Finish: Satin "Dante" D223158* Parma Single Handle Lavatory Faucet Finish: Chrome 1 Sink Conference #103 "Kohler" K -23382 Verse Single BasinSelf- rimming Entertainment kitchen sink "Kohler" K -6665* Wellspring Beverage Faucet w/ Contemporary Styling Finish: CP- Polished Chrome 1 Toilet Restroom #102 "Kohler" K- 3496 -TR Cimarron Comfort Height Two Piece Elongated Toilet w/ Tank cover locks and right hand trip lever Finish: White Supply all the necessary fixtures and fittings 1 Insta -hot Conference #103 "Insinkerator" F- HC1100SN plus SST -FLTR Instant Hot Water Dispenser and filtration system. Finish: Satin Nickel Install to the right of the kitchen faucet Supply all the necessary fixtures and fittings 1 Hot water heater Restroom (above ceiling) Verify style and specification with Owner Supply all the necessary fixtures and fittings Verify @Site Throughout "Hafele" #109.74.601 Modern Zinc Handle 96mm Brushed Nickel verify Per elevations *Complies with Regulation for Barrier -Free facilities Note: Submit all Plumbing product specifications and shop drawings for approval by Designer. Quantities, where listed are for the Contractor's convenience only. Verify all counts. Provide plaster traps and other dental related plumbing needs where necessary. Check with dental supplier for requirements. MISCELLANEOUS ACCESSORIES / HARDWARE SCHEDULE QTY LOCATION SPECIFICATION 1 Restroom "Bobrick" #B -221 Classic Series Surface- Mounted Seat Cover Dispenser Satin finish Stainless Steel 1 Restroom "Bobrick" #B -6806 x 36 ", 11 -1/2" dia. grab bar Satin finish Stainless Steel' 1 Restroom "Bobrick" #B-6806 x 42 ", 1 -1/2" dia. grab bar Satin finish Stainless Steel 1 Restroom "Bobrick" #B-6806 x18 Concealed Mounting 18" Vertical Grab Bar, Stainless Steel, Finish: Satin 1 Restroom "Bobrick" #B -36903 / TrimLine Series Recessed Paper Dispenser / Waste Receptacle / Satin finish Stainless Steel 1 Restroom "Bobrick" #B -6697 / Satin Stainless Steel Finish/ Recessed Toilet Tissue Dispenser w/ Hood for Single Roll 1 Conference "Doug Mockett" 6 "Dia, 2 "deep Trash Management Grommet TM1 B Polished Stainless Steel Doug Mockett 800 - 523 -1269 3 (verify) Office 1, 2, and 3 , "Umbra" #022582 -158 - Stream Double Hook Finish: Nickel. Provide backing, see finish plan for locations. 1 (verify) Conference "Umbra" #022585 -158 - Stream Multi Hook Finish: Nickel. Provide backing, see finish plan for locations. Verify @Site Throughout "Hafele" #109.74.601 Modern Zinc Handle 96mm Brushed Nickel verify Per elevations Provide and install in -wall brackets for support WALL MOUNT EXHAUST FAN Note: Quantities, where listed are for the contractors convenience only. Please verify all counts. ELECTRICAL LGND 1.Security system if applicable, to be designed and installed by others. DUPLEX RECEPTACLE 120V, +VERIFY" AFF 3.Design and install or add sprinkler system per code under separate permit, if applicable. FLUSH FLOOR CAT 5E/ PHONE COMBINATION 5.Washer / Dryer (if applicable): Provide drain line and vent for dryer to exterior of building. 6.Provide conduit for all equipment as required. Verify size and location with Sound System Subcontractor, Computers (data wiring / low voltage wiring contractor), Cabinetmaker and Equipment technician. 7.Where full height 3/4" backsplash is specified, extend plumbing and electrical services 3/4 ". DOUBLE DUPLEX RECEPTACLE 120V, +VERIFY" AFF 9.Barrier -Free Restrooms to have all exposed plumbing insulated. FLUSH FLOOR 4—PLEX 120V 11.Plumber to provide hot and cold water to all sink locations. 12.AII trades working in this plenum must meet all applicable codes. 13.Verify if treatment rooms require separate ground wire per Washington State Electrical Code. See Equipment Suppliers plans for Electrical / Plumbing Notes for all Equipment. DUPLEX RECEPTACLE 120V, +18" AFF 15.Provide and install smoke detectors and recessed fire extinguishers to code. Verify paint color of metal fire extinguisher cabinet w/ Designer. WATER AS REQUIRED BY EQUIPMENT SUPPLIER DUPLEX RECEPTACLE 120V, +7" ACH (2) CAT5—E DATA JACKS, +18 AFF DOUBLE DUPLEX RECEPTACLE 120V, +18" AFF TELEPHONE OUTLET, +18" AFF D '1 DOUBLE DUPLEX RECEPTACLE 120V, +7" ACH CABLE TV OUTLET, VERIFY HEIGHTS W/ AUDIO /VISUAL CONTRACTOR DUPLEX RECEPTACLE 220V, +18" AFF ELECTRICAL PANEL WALL MOUNT EXHAUST FAN FIRE EXTINGUISHER THIS ELECTRICAL PLAN DOES NOT SUPERSEDE FINAL ELECTRICAL PLANS PROVIDED BY ELECTRICIAL / TECHNICIAN. GENERAL ELECTRICAL / PLUMBING NOTES 1.Security system if applicable, to be designed and installed by others. 2.Provide water line to icemaker when applicable. 3.Design and install or add sprinkler system per code under separate permit, if applicable. 4.Call system panels, if applicable, will require a conduit run and power provided by the Electrician. Locations to be job -site verified by Communication Supplier. See plan for general locations but verify locations with Client / Doctor and Designer. 5.Washer / Dryer (if applicable): Provide drain line and vent for dryer to exterior of building. 6.Provide conduit for all equipment as required. Verify size and location with Sound System Subcontractor, Computers (data wiring / low voltage wiring contractor), Cabinetmaker and Equipment technician. 7.Where full height 3/4" backsplash is specified, extend plumbing and electrical services 3/4 ". 8.Dimensioned heights for electrical boxes are to centerline of box and are to be located as specified. If no height specification is called out, check with Designer. 9.Barrier -Free Restrooms to have all exposed plumbing insulated. 10.Electrical Panel and Phone board locations to be verified with Designer. 11.Plumber to provide hot and cold water to all sink locations. 12.AII trades working in this plenum must meet all applicable codes. 13.Verify if treatment rooms require separate ground wire per Washington State Electrical Code. See Equipment Suppliers plans for Electrical / Plumbing Notes for all Equipment. 14.Outlet covers and toggle switches to be standard white unless otherwise noted. When color denotation is required by code, use appropriately colored dot. Verify number of CPU's to be grouped per circuit with Computer installer (no more than four). Use gray dot to denote computer outlets. 15.Provide and install smoke detectors and recessed fire extinguishers to code. Verify paint color of metal fire extinguisher cabinet w/ Designer. 16. Provide water line to pedicure chair when required. Verify with client and equipment supplier. RESTRO 102 CONFERENCE RECEPTION OFFICE 3 106 OFFICE 1 OFFICE 2 ELECTRICAL PLA SCALE: 1 /4 " =1 ' -0" PROVIDE NECESSARY ELECTRICAL AND VENTING. VERIFY LOCATION - VERIFY ALL COMPUTER / TV 1 SOUND SYSTEM / LOW VOLTAGE WITH SUPPLIER - VERIFY REQUIREMENT & LOCATION OF EQUIPMENTS WITH OWNER & SUPPLIER FINISH HARDWARE Provide finish hardware for complete work in compliance with ADA. Quantities, where listed are for the contractors convenience only. Provide all necessary items for all doors, including: butts, latch and locksets, closers, door stops and holders, kick plates, door silencers, thresholds, smoke gasket and weather - stripping. Finish hardware shall be supplied by recognized builder's hardware supplier. Submit hardware schedule for approval. Keys and Keying: Coordinate keying with Owner. All cylinder items shall be master -keyed into a new keying system. Submit keying schedule for approval. LO7 7 3y RECEIVED "'Iry r ri i3'WflA DEC 0 3 2007 B ‘.;N TER logo This set of drawings shall not be copied in whole or in part without prior written consent from the owner. This document is considered as one unit and shall not be considered complete of whole if documents are separated in any manner. Documents shall not be separated for the purpose of submitting proposals or for separate phases of construction. a c V ATO\ ASRRH OFFICE WRAPS, INC. infcrinr docirrn ACH ABOVE COUNTER HEIGHT AFF ABOVE FINISHED FLOOR GROUND FAULT CIRCUIT GFI INTERUPTER REF REFRIGERATOR TV TELEVISION W WATTS OR WALL WH WATER HEATER TANK V VOLTS W/D WASHER / DRYER NOTE: DIMENSIONS GIVEN ARE TO CENTERLINE OF BOX RESTRO 102 CONFERENCE RECEPTION OFFICE 3 106 OFFICE 1 OFFICE 2 ELECTRICAL PLA SCALE: 1 /4 " =1 ' -0" PROVIDE NECESSARY ELECTRICAL AND VENTING. VERIFY LOCATION - VERIFY ALL COMPUTER / TV 1 SOUND SYSTEM / LOW VOLTAGE WITH SUPPLIER - VERIFY REQUIREMENT & LOCATION OF EQUIPMENTS WITH OWNER & SUPPLIER FINISH HARDWARE Provide finish hardware for complete work in compliance with ADA. Quantities, where listed are for the contractors convenience only. Provide all necessary items for all doors, including: butts, latch and locksets, closers, door stops and holders, kick plates, door silencers, thresholds, smoke gasket and weather - stripping. Finish hardware shall be supplied by recognized builder's hardware supplier. Submit hardware schedule for approval. Keys and Keying: Coordinate keying with Owner. All cylinder items shall be master -keyed into a new keying system. Submit keying schedule for approval. LO7 7 3y RECEIVED "'Iry r ri i3'WflA DEC 0 3 2007 B ‘.;N TER logo This set of drawings shall not be copied in whole or in part without prior written consent from the owner. This document is considered as one unit and shall not be considered complete of whole if documents are separated in any manner. Documents shall not be separated for the purpose of submitting proposals or for separate phases of construction. a c OFFICE WRAPS, INC. infcrinr docirrn 570 Kirkland Way Sufte 201 Kirkland, WA. 98033 P: 4255525393 F:425-952-5397 D '1 ER I DATE: 10/15/2007 REVISIONS BY: SCALE: AS NOTED SHEET: CONSTRUCTION SET A4.0 OF: 5 RESTRO 102 CONFERENCE RECEPTION OFFICE 3 106 OFFICE 1 OFFICE 2 ELECTRICAL PLA SCALE: 1 /4 " =1 ' -0" PROVIDE NECESSARY ELECTRICAL AND VENTING. VERIFY LOCATION - VERIFY ALL COMPUTER / TV 1 SOUND SYSTEM / LOW VOLTAGE WITH SUPPLIER - VERIFY REQUIREMENT & LOCATION OF EQUIPMENTS WITH OWNER & SUPPLIER FINISH HARDWARE Provide finish hardware for complete work in compliance with ADA. Quantities, where listed are for the contractors convenience only. Provide all necessary items for all doors, including: butts, latch and locksets, closers, door stops and holders, kick plates, door silencers, thresholds, smoke gasket and weather - stripping. Finish hardware shall be supplied by recognized builder's hardware supplier. Submit hardware schedule for approval. Keys and Keying: Coordinate keying with Owner. All cylinder items shall be master -keyed into a new keying system. Submit keying schedule for approval. LO7 7 3y RECEIVED "'Iry r ri i3'WflA DEC 0 3 2007 B ‘.;N TER logo This set of drawings shall not be copied in whole or in part without prior written consent from the owner. This document is considered as one unit and shall not be considered complete of whole if documents are separated in any manner. Documents shall not be separated for the purpose of submitting proposals or for separate phases of construction. a c