Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL07-770 - WESTFIELD SOUTHCENTER MALL - GUESS
GUESS 467 SOUTHCENTER MALL ELO7-770 Cityf Tukwila Parcel No.: 6364200010 Address: 467 SOUTHCENTER MALL TUICW Suite No: Tenant: Name: GUESS Address: 467 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WEA SOUTHCENTER LLC Address: 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: LAUREN CHASE Address: 626 C ADMIRAL DR, PMB STE 120 , ANNAPOLIS MD Contractor: Name: CLOVER CREEK ELECTRIC Address: 1413 CENTER ST , TACOMA WA Contractor License No: CLOVECE293LA Value of Electrical: $30,000.00 Type of Fire Protection: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us DESCRIPTION OF WORK: INSTALLATION OF NEW LIGHT FIXTURES, AUDIO EQUIPMENT, ELECTRICAL PANELS, RECEPTACLES, SECURITY SYSTEMS, AND ALL REQUIRED WIRING AND CONDUIT. Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Print Name: doc: EL -4/07 ELECTRICAL PERMIT Permit Number: EL07 -770 Issue Date: 04/28/2008 Permit Expires On: 10/25/2008 Phone: Phone: 410 544 -1700 Phone: (253)627 -6648 Expiration Date: 04/30/2010 Fees Collected: National Electrical Code Edition: Date: $717.50 2005 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pe ance of work. I au ed to sign and obtain this electrical permit. Signature Date: y -2g -0 r / This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. EL07 -770 Printed: 04 -28 -2008 Parcel No.: 6364200010 Address: 467 SOUTHCENTER MALL TUKW Suite No: Tenant: GUESS 1: ** *ELECTRICAL * ** Signature fit Print Name: doc: Cond -Elec City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: EL07 -770 Status: ISSUED Applied Date: 12/11/2007 Issue Date: 04/28/2008 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of art electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: 7 2e- - d EL07 -770 Printed: 04 -28 -2008 SITE LOCATION Site Address: Name'RAAy KoPP CITY OF TUKWIL.✓ Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** 3 .50crulcEi t 'SA *'Y AAK1A. Tenant Name: C L,E-S Property Owners Name: WEST F IEcej cart to 4 Aria wJ Mailing Address: /Mal Wuxi/ IJGV Mailing Address: /3 cij r,Jkr R 1 Lr D Q E -Mail AddressrT KGcaA1soc r, a cyst r , J/ET H: Wpplications\Fmms- Applications On Lineal -2007 - Electrical Permit Application.doc Electrical Permit No. Project No. Los A'c &E3 City (For office use only) King Co Assessor's Tax No.: 2423o1c108 1 Suite Number: /Sys Floor: / New Tenant: Yes ❑ .. No cA state Ciao Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Day Telephone:2c - 384'- 1 STA rc CcuEc r IA 148.33 Cit State Zip Fax Number: 814 - 410 - 16 1 !0 ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: city Contact Person: Day Telephone: E -Mail Address: Fax Number Contractor Registration Number: Expiration Date: State Valuation of Project (contractor's bid price): $ Scn ! mo Scope of Work (please provide detailed information): '= a.r c f p., yr LKy arr �r *Tc t�S gtf� £4:1c.% 1 ,Jr i ELEci **ex'. PAW1-5, RE rrAc[C3 SF cs ja i rf S YS? dPt A^I REd , t11Ft7 Wr /rIG A.0) 425,4ikn rT Zip Will service be altered? AT Yes ❑ No Adding more than 50 amps? J Yes ❑ No Type of Use:' -- rA 04. Type of work: ,I New ❑ Addition ❑ Service Change ❑ Remodel 121 Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: Puget Sound Energy ❑ Seattle City Light Page 1 of 2 NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) BUILDING OWNE)t' OR ELEC RI !A . CONTRACTOR: Signature: Print Name: Ad i n Mailing Address: ,,?.2d 8 /Gy'' /el .Q y /Le I ( 6,44- I Date Application Accepted: REsmENTIAL 121 II 1 oit- H: \Applications\Fo ms- Applications On Lineal -2007 - Electrical Permit Application.doc City MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: A 2/ ,/ /6 7 Day Telephone: Zip State Date Application Expires: CO 1 1 1 1 u7 Staff Initials: Page 2 of 2 RECEIPT NO: R08 -01226 Initials: JEM User ID: 1165 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: hup../Iwww.ci.tukwila.wa.us Payee: HORIZON RETAIL CONSTRUCTION, INC. SET ID: 0418 SET NAME: GUESS SET TRANSACTIONS: Set Member Amount D07 -454 2,621.99 EL07 -770 574.00 M07 -271 406.06 PG07 -334 118.00 TOTAL: 3,720.05 TRANSACTION LIST: Type Method Description Payment Check 156585 ACCOUNT ITEM LIST: Description BUILDING - NONRES ELECTRICAL PERMIT - NONR MECHANICAL - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE SET RECEIPT TOTAL: Payment Date: 04/18/2008 Total Payment: 3,720.05 Amount 3,720.05 3,720.05 Account Code Current Pmts 000/322.100 2,619.98 000.322.101.00.0 574.00 000/322.100 406.06 000/322.100 118.00 000/386.904 2.01 TOTAL: 3,720.05 1326 04/18 9711 TOTAL 3720.45 RECEIPT NO: R07 -02719 Initials: JEM User ID: 1165 SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.cLtukwila.wa.us Payee: NATIONAL SERVICES GROUP SET ID: S000000912 SET NAME: Tmp set/Initialized Activities D07 -454 1,705.48 EL07 -770 143.50 M07 -271 94.02 PG07 -334 24.50 TOTAL: 1,96/.50 TRANSACTION LIST: Type Method Description Payment Check 333590 ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE SET RECEIPT TOTAL: Payment Date: 12/11/2007 Total Payment: 1,967.50 Amount 1,967.50 1,967.50 Account Code Current Pmts 000.345.832.00.0 143.50 000/345.830 1,821.51 000/386.904 2.49 TOTAL: 1,967.50 5919 12/11 9710 TOTAL 1967.50 Project: G * 6si Type of Inspection: . 10c) Address: , `( ti Date Called: �^ Special Instructions: 1 Date Wanted: — 7 / (a4r.n. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION re- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: • Approved per applicable codes. El Corrections required prior to approval. Inspector: Date: $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: !Date: COMMENTS: Type of Inspection: + P 104 — FIB Pf4P/AN ri e - Fin/q-t.., kritT. 67 -1S 'yam NoT - Pg-c-Alowc- L S6,5 KE/t? - Liirgro Worm. II Pi 5E em-o($ Fo PIF,ce2.&T VOLT' 6C 5157E-145 Requester: Project: J"7 Type of Inspection: + 2_1 DO Address: t o Date Called: Special Instructions: Date Wanted: ` r lrc� Ca.m„ p.m. Requester: Phone No: PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 42 " 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Approved per applicable codes. El Corrections required prior to approval. 'Inspector: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 0- Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project: C � S Type of Inspection: /Do Address: y �� r r' "' v Date Called: _...". Special Ins 1 Date Wanted: D4i� a, . m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Cz 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 MENTS: O.K. c(iLtAk covat - (6•.4.1.1 I A) Approved per applicable codes. Corrections required prior to approval. (Inspector: 6-61- 710 �Cry (Date: OL't b ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project: 606 .5 Type of Inspection: ^oon Address: � 7 Om/ Date Called: Special Ins ructions: Date Wanted: ' l a Requester: Phone No: INSPECTION RECORD �, 7 _ „� 7 D Retain a copy with permit Lo IN ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION M 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Ig Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Inspector: I Date: (9 01 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project: 6uc... Type of Inspection: loo (A Address: vo tikw Date Called: , 5 Special Instructibns: Date Wanted: 5 1 2 1. C Requester: Phone No: INSPECTION RECORD tP Retain a copy with permit INSPEtIION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 El Approved per applicable codes. El Corrections required prior to approval. COMMENTS: CoVK f)(CEPT !Inspector: 'Date: 0 5 ../ n 0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southebritee Blvd.. Suite 100. Call the schedule reinspection. 6.07-710 'Receipt No.: 'Date: Project: 6 V / 5 Type of Inspection: 7003 Address: ii ' f Date Called: Special Instructions: Date Wanted: s/. 3 t Requester: 4==x-• Phone No: 60/-?70 r --L- 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 4' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ID Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Pk _ 0 . cif cokik 4(64 !Inspector: - &tool\ ( /0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. !Receipt No.: IDate: Project: � j655 Type of Inspection: 70D3 Address: si � i Date Called: Special Instruct ons: Date Wanted: s / i ( J la rr `gym. Requester: Phone No: El Approved per applicable codes. Inspector: INSPECTION RECORD Retain a copy with permit eLo7 77O P MIT NO. INSPEi ION NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Corrections required prior to approval. COMMENTS: - vk cool W 44> r >1- o k411/ (Date: o It 0 El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: (Date: Project: 606iS Type of Inspection: 712°3 Address: 1G1 44 ` Date Called: Special Instructions: Date Wanted: �- ` d:m Requester: Phone No: 6,01-1 INSPECTION RECORD Retain a copy with permit ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION r 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ID Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: PA Inspector: Date: 051/(1 O., ❑ $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Project: 6 65 /5 Type of Inspection: OD/ r Address: - ((p 7 tl Date Called: Special Instructions: Date Wanted: - / / a.m Requester: Phone No: 2 INSPECTION RECORD Retain a copy with permit D INSPECTION NO. O. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: Date: 05 !v 0 El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: V , � Type of Inspection: 7 D0 3 Address: 1 /67 M�A/ Date Called: Special Instructions: Date Wanted: / s ey a.� p.m. Requester: ((( Phone No: 1 Approved per applicable codes. E 7 770 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1ft 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. COMMENTS: PA V\, -- EAU, ITV &A IA 57bet-FI 9.K - J4Dt-e-s-u45 I 0 \ 3 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Inspector: 1t� Receipt No.: 'Date: Project Info . Project Address 633 Southcenter Date 11/16/2007 Seattle, WA 98188 For Building Department Use Space No. 1545 Applicant Name: Randall A. Nelson Applicant Address: 8016 Reeder Road, Lenexa, RS 66214 Applicant Phone: 913 -322 -5150 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Project. Summary PRJ -SUM Revised July 2007 FILE COPY CITY OF TUKWILA DEC 112007 PERMIT CENTER 11At2 Project Info Project Address 633 Southcenter Date 11/16/2007 Seattle, WA 98188 For Building Department Use Space No. 1545 Applicant Name: Randall A. Nelson Applicant Address: 8016 Reeder Road, Lenexa, XS 66214 Applicant Phone: 913 -322 -5150 Project Description Space No. 1545 ❑ New Building ❑ Addition 4 Alteration 4 Plans Induded Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option 0 Prescriptive O Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) Occupancy Description Allowed Watts per ft2** Area in ft Allowed x Area Space No. 1545 Retail 1.50 4591.0 6886.5 Space No. 1545 BA - Recessed Adjustable Spot 36 35.0 1260.0 Space No. 1545 C - Recessed Metal Halid Downlight 15 39.0 585.0 ** From Table 15-1 (over) - document all exceptions on form LTG-LPA Total Allowed Watts 6886.5 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Space No. 1545 A - Ceramic Metal Halide Track Fixture 111 39.0 4329.0 Space No. 1545 BA - Recessed Adjustable Spot 36 35.0 1260.0 Space No. 1545 C - Recessed Metal Halid Downlight 15 39.0 585.0 Space No. 1545 H - 4' Strip Light 1 54.0 54.0 Space No. 1545 F - Metal Halide Adjustable Nall Washer 1 100.0 100.0 Space No. 1545 0 - 8' Strip Light 5 54.0 270.0 Space No. 1545 I - Under Counter Task Light 1 32.0 32.0 Space No. 1545 PA, PS, PC - Decorative Pendant 6 100.0 600.0 Space No. 1545 BB - Recessed Adjustable Spot 44 70.0 3080.0 Fixture A Exempt Per Footnote 10 -111 39.0 - 4329.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 5981.0 Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Maximum Allowed Lighting Wattage Provosed Lighting Wattage 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 Notes: 1. For proposed Fixture Description, indicate fixture type, Tamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, Tamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. Use' LPA` (Wig) Use' LPA` (W/sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) , 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire station 1.0 Cafeterias, fast food establishments', restaurants /bars 1.3 Post office 1.1 Dormitory 1.0 Retail retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia, assembly spaces 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference /exhibition hall'• 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers Q Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) J Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T -4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. 2006 Washington State Nonresidential Energy Code Compliance Form interior Lighting Summary (back) LTG-INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 -1 Unit Lighting Power Allowance (LPA Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices Tess than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 633 Southcenter 'Date 11/16/2007 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) I Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations E1.0 yes 1513.2 Area controls Maximum limit per switch E1.0, E4.0 n.a. 1513.3 Daylight zone control Schedule with type and features, indicate locations n.a. vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib /special Indicate separate controls E1.0, E3.0 1513.5 Exterior shut -off Schedule with type and features, indicate location n.a. (a) timer w/backup Indicate location n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations E1.0 yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans E1.0, E3.0 yea 1513.7 Commissioning Indicate requirements for lighting controls commissioning El.() EXIT SIGNS (Section 1514) yea I 1514 I Max. watts 'Indicate watts for each exit sign 1E1.0 I LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture n.a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) a. a. I 1511 IElec motor efficiency'MECH -MOT or Equipment Schedule with hp, rpm, efficiency I ' TRANSFORMERS (Section 1540) n.a. I 1540 (Transformers (Indicate size and efficiency I I • 2006 Washington State Nonresidential Ener Code Compliance Form If "no" is circled for any question, provide explanation: • Lighting - General Requirements • 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features l isted in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of tuming off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of tuming off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or 2006 Washin •ton State Nonresidential Energy Code Compliance Form illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of turning off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off" feature, which tums off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft or 5% of the building footprint for footprints over 100,000 ft whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry -type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP -1- 2002). Project Info Project Address 633 Southcenter Date 11/16/2007 Seattle, WA 98188 For Building Department Use Space 8 1545 Applicant Name: Randall Nelson Applicant Address: 8016 Reeder Rd. Lenexa, RS 66214 Applicant Phone: 913-322-5150 2006 Washington State Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms REVIEWED FOR CODE COMPLIANCE NFPA70 -NEC JAN - 2 2008 City Of Tukwila B ILDIN D ION Revised July 2007 RECEIVED CITY OF TUKWILA FILE COPY DEC 112007 PEHMIT CENTER •Eal---11T Cooling Equipment Schedule Equip. ID Brand Name Model No. Capacity2 Btu/h Total CFM OSA CFM or Econo? SEER or EER IPLV Location TRANS VSEF -16 3000 Randall Nelson VAV CEILING VAV -2 TRANS VCEF -12 1000 VAV CEILING Fan Equipment Schedule Equip. ID Brand Name' Model No. CFM SP' HP /BHP Flow Control Location of Service VAV -1 TRANS VSEF -16 3000 Randall Nelson VAV CEILING VAV -2 TRANS VCEF -12 1000 VAV CEILING Heating Equipment Schedule Equip. ID Brand Name' Model No. Capacity2 Btu/h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency' Space t 1545 Applicant Name: Randall Nelson Applicant Address: 8016 Reeder Rd. Lenexa, KS 66214 Applicant Phone: 913- 322 -5150 Project Info • Project Address 633 Southcenter Date 11/16/2007 Seattle, WA 98188 For Building Dept. Use Space t 1545 Applicant Name: Randall Nelson Applicant Address: 8016 Reeder Rd. Lenexa, KS 66214 Applicant Phone: 913- 322 -5150 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Description Briefly describe mechanical system type and features. ❑ Includes Plans Include documentation requiring compliance with commissioning requirements, Section 1416. Compliance Option Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 'If available. 2 As tested according to Table 14 -1A through 14 -1 G. 3 1f required. 4 COP, HSPF Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? ❑ Packaged sys? ❑ <20,000 Btuh? ❑ Economizer included? If Heating Only: ❑ <5000 cfm? ❑ <70% outside air? Mechanical Summary (back) MECH -SUM Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. 'Decision Flowchart 1 Heating Only 2006 Washington State Nonresidential Energy Code Compliance Form Simple System Allowed (section 1420) Yes — Yes* ( Reference Section 1421 otal Ca •. wo economize <240,000 Btuh or 10 %1 Heating /Cooling or Cooling Only Yes Yes Reference Section 1423 Yes Yes Yes • Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical- Complex Systerns'Checklist MECH -COMP 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 633 Southcenter Date 11/16/2007 The following additional information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH - CHK checklist for additional system requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptable alternative. For Building Department Use Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY n.a. 1431.1 Field assem. sys. Provide calculations n.a. 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans n.a. 1432.2.1 Air system reset Indicate automatic reset n.a. 1432.2.2 Hydronic System Indicate automatic reset, cooling tower, & heat pump loop valves n.a. 1433 Air Economizer Indicate economizer on equipment schedule or provide calculations to justify exemption and demonstrate 10% higher efficiency for equipment with out economizer. n.a. 1433 Water Economizer Indicate water economizer and provide calculations if 1433 Exception 2 is utilized n.a. 1434 Separate air sys. Indicate separate systems on plans n.a. 1435 Simul. ht g. & clg. g g Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified n.a. 1436 Heat recovery Indicate heat recovery on plans; complete and attach heat recovery calculations n.a. 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp, rpm, efficiency yes 1438 Variable flow sys. Indicate variable flow on fan and pump schedules M2 n.a. 1439.1 Kitchen Hoods Indicate uncooled and unheated make -up air n.a. 1439.2 Fume Hoods Indicate VAV, unheated/uncooled or heat rec. makeup BUILDING SYSTEM IS EXISTING. ( Start Here T Section 1411.1 Equipmen Efficiency Shall Meet Tables 14 -1A through 14 -1G Yes 4, 1411.1 Intermittent Ignition Device & Power Venting or Damper. If input Btuh then 1412.6 Modulating or Staged Combustion Controls Required 2006 Washington State Nonresidential Energy Code Compliance Form no is circled for any question, provlae explanation: Decision Flowchart Use this flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for more complete information on the requirements. s/Oil Fuma input > 225,000 tuh or Gas/O' • Heat apacity of H Heating System > 00,000 Btuh? Yes 4, 1411.1 0.75% Maximum Jacket Loss a Yes Section 1431.1 Calculations of Total On -Site Energy Input & Ouput Required (continued on back) Yes 4, Section 1432.2.1 Supply Air Reset Controls Required Yes No Section 1432.2.2 Hot Water Supply Temperature Reset Required 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Complex. Systems (back) MECH- COMP 2006 Washington State Nonresidential Energy Code Compliance Forms 0% Air Econ Provided? Section 1413 Water Cooled w/Water Econo? Total Clg Capacity w/ Water Econo 500 Tons pply Air >5,0 cfm & OSA > 70% otorInd.l qpmt Covr'd by Tbl 14- 1A -14- 1G? EER 10% Better than Code tal Cap. cono <= 480,00 Btuh or 20% of otal Cap. Section 1436 50% Effective Heat Recovery Required Yes Yes • DONE Yes.♦ stern or Zon w/ Simultaneous Htg. & Clg.? Application Involves Variable Flow? Section 1435 Zone Controls Must Reduce Supply Air Quantity Before Reheating/Recooling Section 1439.1 No Heating or Cooling for at Least 50% of Make -up Air Yes No-* Section 1433 Economizer Required Yes Section 1437 Motors Must Meet Efficiencies in Table 14-4 Section 1438 Variable Flow Devices Required Section 1439.2 One Required: a. 50% VAV Exhaust & Make -up b. 75% Direct Makeup w/ Tempering Only c. Heat Recovery per 1436 d. Constant Volume w/ < 5ofpm Face Velocity Yes Revised July 2007 Open Motors dosed Motors 3,600 I 1,800 1 1,200 3,600 1 1,800 1 1,200 Efficiency ( %) Efficiency (%) - 825 80.0 75.5 825 80.0 82.5 84.0 84.0 82.5 84.0 85.5 84.0 84.0 85.5 84.0 84.0 86.5 84.0 86.5 86.5 85.5 87.5 87.5 85.5 87.5 87.5 87.5 87.5 87.5 87.5 88.5 88.5 88.5 89.5 89.5 88.5 89.5 90.2 89.5 89.5 89.5 89.5 91.0 90.2 90.2 91.0 90.2 90.2 91.0 91.0 90.2 91.0 90.2 91.0 91.7 91.7 91.0 924 91.7 91.0 924 92.4 91.0 924 91.7 91.7 93.0 93.0 91.7 93.0 93.0 92.4 93.0 93.0 924 93.0 93.0 93.0 93.6 93.6 93.0 93.6 93.6 93.0 94.1 93.6 93.0 94.1 93.6 93.0 94.1 94.1 93.6 94.5 94.1 93.6 94.5 94.1 94.5 94.5 94.1 93.6 95.0 94.5 94.5 95.0 95.0 94.5 95.0 94.5 95.0 95.0 95.0 Electric; Motors MECH -MOT 2006 Washington State Nonresidential Energy Code Compliance Forms Project Address Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). Motor No. or Location Minimum Nominal Full -Load Efficienc Synchronous Speed (RPM) HP 1.0 1.5 20 3.0 5.0 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 HP 2006 Washington State Nonresidential Energy Code Compliance Form 633 Southcenter Type (open/closed) Description of Application or Use Date Synch. Speed 11/16/2007 For Building Department Use Revised July 2007 Min.Nom. Full Toad Efficiency Exceptions: 1. Motors in systems designed to use more than one speed of a multi - speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14- I A or 14-1B). 3. Motors that are an integral part (i.e. not easily removed and replaced) of specialized process equipment (i.e. equipment which requires a special motor, such as an explosion - proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (i.e. if the only U.L. listing for the equipment is with a Tess- efficient motor and there is no energy - efficient motor option). For motors claiming an exception, list motor and note which exception applies. Mechanical Permit 2006 Washington State Nonresidential Plans Cfecklist MECH -CHK Energy Code Compliance Forms Revised July 2007 Project Address 633 Southcenter 'Date 11/16/2007 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 - 1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule n.a. 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency n. a 1411:1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls 1412.1 Temperature zones Indicate locations on plans 1412.2 Deadband control Indicate 5 degree deadband minimum n.a. 1412.3 Humidity control Indicate humidistat 1412.4 Automatic setback Indicate thermostat with night setback and 7 dill. day types n.a. 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage 241 yes 1412.4.2 Optimum Start Indicate optimum start controls n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans M1 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans n.a. 1423 Economizers Equipment schedule 1413 Air economizers n.a. 1413.1 Air Econo Operation Indicate 100% capability on schedule n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate clg Toad & water econoe & clg tower performance n.a. 1413.3 Integrated operation Indicate capability for partial cooling n.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary M1 yes 1414.2 Duct insulation Indicate R -value of insulation on duct M1 yea 1415.1 Piping insulation Indicate R - value of insulation on piping M2 1416 Completion Requirements n.a. 1416.2.1 Commissioning Provide commissioning plan n.a. 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing n.a. 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training n.a. 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report n.a. 1434 Separate air sys. Indicate separate systems on plans I Mechanical ( Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 - 1454) 1440 Service water htg. n.a. 1441 Elec. water heater Indicate R -10 insulation under tank n.a. 1442 Shut -off controls Indicate automatic shut -off yes 1443 Pipe Insulation Indicate R -value of insulation on piping M2 n.a. 1452 Heat Pump COP Indicate minimum COP of 4.0 n.a. 1452 Heater Efficiency Indicate pool heater efficiency n.a. 1453 Pool heater controls Indicate switch and 65 degree control n.a. 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form is circled for any question, proviae explanation: 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms MECH-CHK Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings? 225,000 Btu/h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (111 4, and have either mechanical draft (including power venting) or a flue damper. A vent damper Is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used In combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that Is capable of shutting the system off when no occupant Is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery com plying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and retum air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling Toad served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 Inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms MECH-CHK Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings? 225,000 Btu/h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (111 4, and have either mechanical draft (including power venting) or a flue damper. A vent damper Is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used In combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that Is capable of shutting the system off when no occupant Is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery com plying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and retum air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling Toad served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 Inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying 2006 Washington State Nonresidential Energy Code Compliance Form 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2. are isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels Immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating Is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 000 EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. Jennifer Marshall - Guess Southcenter Tukwila WA Change of contact From: "Lauren Chase" <lauren _chase @nationalpermits.com> To: "Jennifer Marshall" <jarshall @ci.tukwila.wa.us> Date: 01/09/2008 1:16 PM Subject: Guess Southcenter Tukwila WA Change of contact CC: "'Lauren Chase.NSG (Lauren Chase.NSG)"' <lauren_chase@nationalpermits.com> From: Lauren Chase, National Account Manager National Services Group 626 C Admiral Drive, Pmb Suite 120 Annapolis, MD 21401 Tel 410 544 1700 Fax 410 544 1692 Lauren : Cell 443 994 8531 <mailto: Lauren _chase@nationalpermits.com> http: / /www.nationalpermits.com Westfield South Center Mall Guess # Guess 633 Southcenter Mall Space 1545 Tukwila WA 98188 D07 -454 EL07 - 770 M07 - 271 PG07 - 334 Brett Delmez Tel 314 - 721 -1340 PM Mobile # Arch : Epoch GC : Pdg Re: Report To: Retail Dev Team : 1) Change of contact request (To : Lauren Chase ) 2) Please forward the latest comments (12 21 07 ) If you have any questions, please contact the writer at Tel 410 544 1700 Page 1 of 2 k file: / /C:\ Documents %20and %20Settinas \iennifer -m\ Local %20Settines \Temn\XPGmWis... 01/09/2008 Thank You Lauren Chase, National Account Manager National Services Group, Inc Page 2 of 2 NSG INC 2006 All Rights Reserved . This Document and the associated documentation are the property of NSG INC and may be used under license as authorized by NSG INC. Please Note : All reporting data / status / estimates / accuracy are time sensitive and may / will be revised / updated ,please contact the NSG and or the goveming jurisdiction if you have any questions . Final Approval is directly contingent upon acceptance and approval by the governing jurisdictional authorities of the required Owner / Designer / Contractor documentation.Approval Notification : The Client and /or their General Contractors , Subcontractor(s), Vendor(s) must submit their required License(s) , Insurance(s) , Bond(s) , Fee(s),etc as required to the governing jurisdictions This email and any attachments are confidential and intended solely for the use of the named addressee. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and deiete this e from your system. If you are not the intended recipient you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited. E -mail transmission cannot be guaranteed to be secure or error -free as information could be intercepted. corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard -copy version file: / /C:\ Documents %20and %20S ettings \j ennifer -m\ Local %20Settings \Temp\XPGroWis... 01/09/2008 ACTIVITY NUMBER: EL07 -770 PROJECT NAME: GUESS SITE ADDRESS: 467 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # DATE: 12 -12 -07 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Buil Ing Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 1 2-13-07 Complete F, Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP C Fire Prevention Structural Structural Review Required DATE: DATE: Planning Division Permit Coordinator n Not Applicable ❑ ❑ No further Review Required n DUE DATE: 01-10-08 Approved El Approved with Conditions 0 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License CLOVECE293LA Licensee Name CLOVER CREEK ELECTRIC Licensee Type ELECTRICAL CONTRACTOR UBI 601047056 Ind. Ins. Account Id Business Type CORPORATION Address 1 1413 CENTER ST Address 2 City TACOMA County PIERCE State WA Zip 98409 Phone 2536276648 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 6/1/1971 Expiration Date 4/30/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License SCHUMH *960K6 Business Owner Information Name Role Effective Date Expiration Date SCHUMACHER, A H 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full - time supervisory employee. Master Electrician Information License Name Status SCHUMH *960K6 SCHUMACHER, A H ACTIVE Bond Information https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= CLOVECE293LA 04/28/2008 LIGHT FIXTURE SCHEDULE SYMBOL TYPE MANUFACTURER MODEL # LAMP VOLTAGE WATTS DESCRIPTION NOTES A SPECIALTY LIGHTING GROUP 056- 20G2- B- AJ -12B (1) 39W CMH 120/12 39 CERAMIC METAL HALIDE TRACK FIXTURE BA, BB RSA LIGHTING COT4(X)MH -WH -WH (1) 35W MH 120 35,70 RECESSED ADJUSTABLE SPOT 5 0 1001 0 C SPECTRUM SP7- MH- 35- H1- 7210CL (1) 35W MH 120 39 7" RECESSED DOWNLIGHT 7 E METALUX SS- 232 - UNV -EB81 (2) 32W T8 120 54 4' STRIP LIGHT I I SPECTRUM LIGHTING ED17- 100 -EX- PDWW /ED17 (1) 100W MH 120 100 ADJUSTABLE WALL WASHER 1 1 I G METALUX 8T -SS- 132 - UNV -EB81 (2) 32W T8 120 54 8' STRIP LIGHT I I LIGHTOLIER TCU- 40- W- UNV- RO -BPR (1) 32W T8 120 32 UNDER COUNTER TASK LIGHT 3 I I O) PA, PB, PC VISO BOLIO INCLUDED 120 100 DECORATIVE PENDANT 6 1 T CON —TECH LT —X —B — — — 2', 4', 6', 8', OR 12' LENGTH TRACK 1,2 1 X1 PATHWAY LTEX1CRC INCLUDED 120 5 EDGE LIT EXIT SIGN WITH BATTERY BACK UP 4 EM1 PATHWAY AR -2 -DL INCLUDED 120 12 EMERGENCY LIGHT WITH BATTERY BACK UP EM2 EVENLITE APRGC- 25 -LC -UI INCLUDED 120 25 RECESSED EMERGENCY LIGHT WITH BATTERY BACK UP • • teP EM3 ASTRALITE EEU -U -R -W INCLUDED 120 10 EXIT SIGN WITH EMERGENCY LIGHTS NOTES: Public Works, Building Division CITY RECEIVED T 1. PROVIDE LENGTH OF TRACK REQUIRED TO MATCH PLAN. PERMIT NUMBER PER 2. PROVIDE WITH TOP ACCESS END FEEDS (LA - 10 - 8) AND MINI - CONNECTORS (LA - 2 - B). DEC 1 1 2007 3. SEE MANAGER'S DESK DETAIL ON SHEET E3.0 FOR MOUNTING LOCATION. A ` � y 4. PROVIDE WITH RED LETTERS ON CLEAR BACKGROUND. FOR DOUBLE FACE, PROVIDE WITH A MIRRORED BACKGROUND. 5. REPLACE "X" IN MODEL NUMBER WITH NUMBER OF LAMPS AS SHOWN ON PLAN. BA = 1 LAMP; BB = 2 LAMPS pp� " -;T - ._ • e; � 6. PA = SMALL DIAMETER FIXTURE; PB = MEDIUM; PC = LARGE, f '._ .... 7. PROVIDE WITH SPECTRUM LIGHTING HANGER BAR BH27, A A A A IA A A A 00 BB 1 BB ridI naw . Orl d�i��f 'prior a Tukwila tlkiilT:iifl9 Divls14 NOTE: `i evisions will require an and may include additional plan review fe 0 BB �BA LP 17 BA BA A 1 0 BA BB ex: 20 FILE Permit No. Plan review approval le table ° to errom and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field r ' and erl tr acknowledged: Date: City of Tukwila OU DINE DIVIS'O! SCALE: 1 /4 " =1' -0" v 1-1% [. ' PEB S (�- U1RE V 1'' ✓l Mechanical 0 Electrical ilurnbin9 X G as Piing I' City of Tukwila FOR LIGHTING CONTROLS WHICH INCLUDE DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, AUTOMATIC SHUT —OFF CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME SWITCHES, THE LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. ELECTRICAL CEILING PLAN PANELBOARD 'LP' PANELBOARD 'PP' TRANSFORMER PANELBOARD 'HP' LP 4 APPRO'E.D P1 ' 797CIF:12,AT!Ot1S SHALL. r1ryT ''.L.I:1A.;OED, MODIFIED OR ALTERED WITHOUT virrHour AUTHORIL+TION FROM THE BUILDING OFFICIAL, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANSAN!) I5 CI.J1I2CT TO FIELD INSPECTIONS 0 SCALE: N/A LP 9 LIGHTING FIXTURE SCHEDULE NOTE: EXISTING CONDITIONS WERE TAKEN FROM SITE VISITS AND MAY NOT REFLECT EXACT "AS— BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. 1 2 3 4 5 6 7 8 9 10 11 PROVIDE DISCONNECT AND JUNCTION BOX FOR SIGN. COORDINATE ALL REQUIREMENTS WITH SIGN VENDOR PRIOR TO ROUGH -IN. REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFORMATION. DUPLEX RECEPTACLE MOUNTED IN CEILING FOR SHOW WINDOW REQUIREMENTS. CONNECT FIXTURE TO UNSWITCHED CIRCUIT LP -2 FOR EXIT SIGNS, EMERGENCY LIGHTS, AND NIGHT LIGHTS. CONNECT EMERGENCY /EXIT FIXTURE TO UNSWITCHED LEG OF LIGHTING CIRCUIT SERVING AREA. LIGHT FIXTURE MOUNTED WITHIN MANAGER'S DESK. REFER TO MANAGER'S DESK DETAIL ON SHEET E3.0. ROUTE CIRCUIT THROUGH AUTOMATIC TIME CLOCK CONTROLLED LIGHTING CONTACTOR. REFER TO AUTOMATIC CONTROLS DETAIL ON SHEET E3.0. INSTALL SPEAKERS PROVIDED BY TENANT. SPEAKERS SHALL BE FLUSH MOUNTED IN CEILING. PROVIDE JUNCTION BOX AND 70 VOLT SPEAKER WIRE IN 3/4 "C FROM RECEIVER TO SPEAKERS. FIELD VERIFY EXACT LOCATION WITH GENERAL CONTRACTOR. EXHAUST FAN BY OTHERS. INSTALL COMPLETE AND READY FOR OPERATION. LIGHTING CONTACTOR OVERRIDE TOGGLE SWITCHES WITHIN SIGHT OF LOAD BEING CONTROLLED. REFER TO AUTOMATIC CONTROLS DETAIL ON SHEET E3.0. PROVIDE MOTION SENSOR SWITCH, HUBBELL MODEL # ATP1277W, OR EQUAL. CEILING PLAN KEYED NOTES SCALE: N/A THE REFLECTED CEILING PLAN SHALL GOVERN ALL PENETRATION LOCATIONS. MECHANICAL DUCTWORK AND ALL ELECTRICAL CONDUITS SHALL BE RUN TO AVOID CONFLICT WITH THE REFLECTED CEILING PLAN. GENERAL CONTRACTOR SHALL NOTIFY UPON THE START OF PROJECT IF EXISTING DUCTWORK, CONDUIT OR OTHER EXISTING SYSTEMS WILL CONFLICT WITH THE PROPOSED REFLECTED CEILING PLAN. NO MODIFICATIONS TO THE REFLECTED CEILING PLAN WILL BE ACCEPTED DUE TO INSTALLATION OF CONTRACTOR PROVIDED SYSTEM OR EQUIPMENT. REFER T!..) ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF FIXTURES. DIMENSIONS SHOWN ON ARCHITECTURAL REFLECTED CEILING PLAN ARE FINISH DIMENSIONS UNLESS NOTED OTHERWISE. BATTERY PACK FOR EXIT SIGNS AND EMERGENCY LIGHTS MUST BE REMOTE OR RECESSED UNLESS INTEGRAL TO FIXTURE. ALL CEILING HEIGHTS ARE BASED ON FINISH FLOOR HEIGHT. GENERA?.. CONTRACTOR TO INFORM ARCHITECT OF ANY DISCREPANCIES /OBSTRUCTIONS PRIOR COMMENCING WORK. ALL SUSPENSION FASTENING DEVICES SHALL BE SUSPENDED FROM STRUCTURE ABOVE WITH ADEQUATE STRUCTURAL STEEL. GENERAL NOTES SCALE: N/A PR U P-4 PROJECT TEAM: Architect: Epoch Design Group, Inc. 1 155 Olivette Exec. Pkwy. Suite 100 St. Louts, MO 63132 TEL: 314.721.1340 FAX: 314.721.0344 M. E. P. & F.P. Engineer: COPYRIGHT DISCLAIMER: THIS DOCUMENT IS THE PROPERTY OF EPOCH DESIGN GROUP, COPYRIGHTED AS DATED, ALL RIGHTS RESERVED. AUTHORISATION FROM EPOCH DESIGN GROUP FOR USE OF THIS DOCUMENT IS NOT TRANSFERABLE. THE RECIPIENT OF THIS DOCUMENT I5 HEREBY ADVISED THAT IT 15 RELEASED FOR USE UNDER THE FOLLOWING TERMS AND CONDITIONS: THE DOCUMENT 15 TO BE USED ONLY IN CONJUNCTION WITH THIS PROJECT. REUSE OF ANY PORTION OF THE DOCUMENT IN ANY OTHER CIRCUMSTANCE CONSTITUTES COPYRIGHT INFRINGEMENT. THE DOCUMENT I5 FOR DESIGN INTENT AND INFORMATION ONLY, AND DOES NOT CONSTITUTE AS -BURT CONDITIONS. THE RECIPIENT RETAINS THE OBLIGATION TO VERIFY THE CONDITIONS OF THE SUBJECT PROPERTY AND TO COMPLETELY COORDINATE ALL DIMENSIONS, FABRICATION METHODS, RELATED AND INTEGRATED SYSTEMS, ETC, WITH RESPECT TO ALL ASPECTS OF THE WORK. EPOCH DESIGN GROUP MAKES NO WARRANTY AS TO THE SUITABILITY OF THE DOCUMENT FOR THE RECIPIENT'S INTENDED USE. THE RECIPIENT SPECIFICALLY AGREES TO WAIVE AND TO INDEMNIFY AND DEFEND ANY AND ALL CLAIMS AGAINST EPOCH DESIGN GROUP, ITS CONSULTANTS, ANY OF ITS RELATED ENTRIES, VENDORS, OR CONTRACTORS, FOR MY LOSS INCURRED AS A RESULT OF PROPER OR IMPROPER USE OF THIS DOCUMENT. THE RECIPIENT A E -_v = �RNOJF Y THIS DOCUMENT UPON COMP ... ••' 1 03 TERALfJATION 9F $I(,FERFORMED RV IS PROJECT. E Gj • Z 1.•C' ' PROJECT TITLE: O� CO 0 O vi w SHEET TITLE: DRAWN BY: LBS ISSUE DATE: 11/07/07 434€8.. /ONAL 1 Ormird RANDALL A. NELSON 8016 Reeder Rd. Lenexa, KS 66214 TEL, 913 - 322 -5150 FAX, 913- 322 -5155 0 ELECTRICAL CEILING PLAN Q N M a ( 7 . 7 7 a V 00 IL N X N E 0 I n Z N w 0 z ui w �v a. N 1- m No.Q Revision Description Date PROJECT NO.: SHEET NUMBER: 07073 E1.0 FILE CiPY it\ 11 PP 9 PP PANELBOARD 'LP' PANELBOARD 'PP' TRANSFORMER 'T1' PANELBOARD 'HP' TO PU BU TTON AT TO PUSH - DOOR BUTTON IN CASHWRAP TO PUSH - BUTTON AT REAR DOOR TO CHIME IN STOCK ROOM II I III 1 6 66666 - PP -12 PP -14 PP- 8 SENSORMATIC FLOOR SENSORS 20 TO BUZZER IN`' STOCK ROOM GF PP 23 pp 13 zeta PROVIDE (2) 1"C TO COMM. STRUCTURE ELECTRICAL POWER PLAN SCALE: 1 /4 " =1' -0' pp 22 COMMUNICATION STRUCTURE I II II FT] PROVIDE POWER FOR FRONT CASHWRAP RECEPTACLES ROUTED FROM JUNCTION BOX CASHWRAP STUB UP. PROVIDE RECEPTACLES WITHIN CASEWORK AT LOCATIONS COORDINATED WITH CASEWORK CONTRACTOR. VERIFY CONDUIT ROUTING WITHIN CASEWORK FIELD VERIFY EXACT FEED LOCATION FROM WALL. L 211 DUPLEX RECEPTACLE FOR MICROWAVE MOUNTED AT +42" AFF. COORDINATE EXACT LOCATION. L ] DUPLEX RECEPTACLE FOR REFRIGERATOR MOUNTED AT +15" AFF. COORDINATE EXACT LOCATION. 5 6 7 9 18 GFCI RECEPTACE FOR RESTROOM SINK AT +42" AFF. COORDINATE EXACT LOCATION. GFCI RECEPTACE FOR INSTANTANEOUS WATER HEATER. SEE MECHANICAL DRAWINGS FOR MORE INFORMATION. TENANT'S CONTRACTOR TO FURNISH WITH EQUIPMENT AS FOLLOWS: A. PUSHBUTTON - - -- EDWARDS IN CASHWRAP. B. BUZZER EDWARDS CEILING AND IN CASHWRAP. C. TRANSFORMER EDWARDS D. CHIME EDWARDS AND INSTALL SERVICE DOOR SIGNAL #852. MOUNT AT +4' -0" AFF AND #340A -G5. MOUNT IN STOCKROOM #88 -50. MOUNT AT +8' -0" AFF #338 -G5. MOUNT AT +8' -0" AFF PROVIDE 20 AMP, 110 VOLT JUNCTION BOX AND DEDICATED DUPLEX RECEPTACLE (WITH ISOLATED GROUND) FOR ANTENNA DIRECTLY ABOVE DOOR. JUNCTION BOX NEEDS 1" CONDUIT WITH A PULL STRING TO RUN TO THE COMM. STRUCTURE. COORDINATE EXACT LOCATION. FLUSH JUNCTION BOX AT +42" AFF WITH 3/4" CONDUIT WITH PULL STRING TO CEILING SPACE FOR ROBBERY ALARM PAD. COORDINATE EXACT LOCATION AND OTHER RELATED ELECTRICAL REQUIREMENTS. 20 AMP RATED JUNCTION BOX WITH ISOLATED GROUND ABOVE CEILING FOR SENSORMATIC SYSTEM. THE AC SOURCE MUST BE A 3 WIRE 24 HOUR UNSWITCHED OUTLET WITH LESS THAN 0.5 VAC BETWEEN NEUTRAL AND GROUND. PROVIDE 'LOCK -ON' DEVICE ON BREAKER AT PANEL. PROVIDE 1" OR 3/4" CONDUIT FROM POWER RACK ABOVE CEILING DOWN TO EACH ANTENNA IN FLOOR. CONDUIT RUN CANNOT EXCEED 30 FEET AND MUST BE HIDDEN IN WALL. VERIFY EXACT SPECS WITH SENSORMATIC ELECTRONIC CORPORATION C/O ED ENGLAND AT 800 - 297 -1442. POWER PLAN KEYED NOTES SCALE: N/A TENANT WORK: GENERAL REQUIREMENTS TENANTS SHALL PROVIDE THE FOLLOWING: • EXTEND, AS REQUIRED WITHIN THE DEMISED PREMISES, THE ELECTRICAL SERVICE FEEDER TO TENANT'S MAIN DISCONNECT SWITCH OR MAIN CIRCUIT BREAKER EQUIPPED PANEL BOARD. • TENANT'S ELECTRICAL SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH LANDLORD'S CRITERIA AS OUTLINED IN THIS MANUAL, THE LATEST ADOPTED EDITIONS OF THE NEC AND THE REQUIREMENTS OF ALL LOCAL AUTHORITIES HAVING JURISDICTION. MATERIALS, ELECTRICAL PRODUCTS AND EQUIPMENT, INCLUDING ALL COMPONENTS SHALL BE NEW AND APPEAR ON THE UNDERWRITERS LABORATORIES LIST OF APPROVED ITEMS. • TENANT SHALL INSTALL ALL ELECTRICAL WORK NECESSARY FOR A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM WITHIN THE PREMISES, INCLUDING, WITHOUT LIMITATION, TRANSFORMERS, ELECTRICAL PANELS, DISCONNECT SWITCHES, ETC. CONDUIT AND WIRES: 1 : ALL MAIN FEEDER WIRES FROM THE MAIN ELECTRICAL SWITCH SHALL BE SIZED TO MEET THE MINIMUM FUSE PROTECTION CAPACITY OF TENANT'S MAIN ELECTRICAL CIRCUIT BREAKER. MAIN SERVICE FEEDERS, AS A MINIMUM, SHALL BE TREATED FOR THE SUM OF ALL LOADS, PLUS TWENTY -FIVE PERCENT (25 %) SPARE CAPACITY. BRANCH CIRCUITS CONNECTED LOADS SHALL NOT EXCEED EIGHTY PERCENT (80 %) OF RATED CAPACITY. 2 • MINIMUM CIRCUIT WIRE SIZE SHALL BE #12 AWG, EXCLUDING CONTROL WIRING. ALL MAIN AND BRANCH CIRCUITRY WIRING SHALL BE COPPER. ALL WIRING IS TO HAVE 600 -VOLT INSULATION, TYPE TW, THW, THWN OR THHN FOR MAIN FEEDERS. SAME COLOR SHALL IDENTIFY SAME PHASE THROUGHOUT THE SYSTEM. 3 : AT NO TIME CAN FLEXIBLE CONDUIT BE USED AS COMMON ROUTING FOR WIRES. 4 : PANEL CONNECTED LOADS WITHIN THE TENANT SPACE AND MAIN FEEDER CONDUCTORS (FROM LANDLORD SWITCHGEAR TO PANEL) SHALL BE BALANCED WITHIN PLUS OR MINUS TEN PERCENT (10 %) ACROSS ALL PHASES. 5 : ALL CONDUITS SHALL BE CONCEALED IN FINISHED AREAS. MINIMUM CONDUIT SHALL BE ONE -HALF INCH (1/2 ") DIAMETER AND CONCEALED IN SLAB SHALL BE THREE - QUARTER INCH (3/4 "). NO CONDUIT IS ALLOWED TO BE INSTALLED IN THE SLAB UNLESS ABSOLUTELY NECESSARY. COORDINATE ALL IN SLAB WORK WITH LANDLORD'S STRUCTURAL ENGINEER. 6 • ALL WIRING SHALL BE INSTALLED IN CONDUIT. CONDUIT SHALL BE GALVANIZED STEEL, RIGID HEAVY WALL OR ELECTRICAL METALLIC TUBING. WATERTIGHT FITTINGS SHALL BE USED WHERE REQUIRED BY CODE. 7 : CONDUIT HANGERS, CLAMPS, LIGHT FIXTURESUPPORTS, ETC SHALL BE FASTENED TO BAR JOISTS OR BEAMS. NO ATTACHMENT OR SUPPORT FROM ANY ROOF DECK IS ALLOWED. EXPOSED CONDUITS SHALL BE IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES OR BEAMS AND SEPARATED AT LEAST THREE INCHES (3 ") FROM WATER OR GAS LINES, WHEREVER THEY RUN ALONGSIDE OR ACROSS SUCH LINES. 8 : FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR CONNECTIONS INSIDE CASEWORK AND AS THE FINAL CONNECTION FOUR FEET (4' -0 ") MAXIMUM LENGTH, MINIMUM ONE -HALF INCH (1/2 ") ELECTRICAL TRADE SIZE TO RECESSED FIXTURES, MOTORS AND ELECTRICAL EQUIPMENT THAT MAY GENERATE VIBRATION THROUGH THE CONDUIT SYSTEM. NO BX, AC, MC OR ROMEX TYPE WIRING CAN BE ALLOWED. FURNISH LIQUID -TIGHT FLEXIBLE CONDUITS FOR OUTDOOR INSTALLATIONS AND FLOOR BOXES SHALL BE WATERTIGHT WITH CAST THREADED CONDUIT HUBS. 9 : PULL BOXES OR JUNCTION BOXES ARE REQUIRED TO BE OF MINIMUM TWELVE- (12) GAUGE GALVANIZED STEEL. BOXES IN WALLS SHALL BE GALVANIZED PRESSED STEEL OR CAST METAL. CAULK AROUND BOXES TO ELIMINATE NOISE TRANSMISSION. 10 • THE ELECTRICAL SYSTEM SERVING THE TENANT SPACE SHALL BE GROUNDED IN ACCORDANCE WITH THE LATEST REQUIREMENTS OF THE NEC. 11 • GROUND FAULT CIRCUIT INTERRUPTERS SHALL BE INSTALLED IN BRANCH CIRCUITS, WHERE REQUIRED BY CODE. 12 : PRIOR TO MAKING ANY CONDUIT, PIPE OR DUCT -ROOF PENETRATION AND /OR POSITIONING ANY EQUIPMENT ON THE ROOF, ALL THE PROPOSED LOCATIONS AND /OR PENETRATIONS SHALL MATCH LOCATIONS, AS INDICATED ON THE LANDLORD- APPROVED PLANS AND BE APPROVED BY LANDLORD'S ON -SITE REPRESENTATIVE. 13 • ALL TENANT EQUIPMENT ON THE ROOF SHALL BE LABELED WITH TENANT NAME AND SUITE NUMBER. ALL TENANT EQUIPMENT MUST BE LOCATED IN THE LANDLORD APPROVED LOCATION. ALL ROOF PENETRATIONS SHALL BE MADE AT THE TENANT'S EXPENSE BY A LANDLORD APPROVED ROOFING CONTRACTOR PER THE LANDLORD SPECIFICATIONS. ALL WATERPROOFING SHALL BE DONE AT THE TENANT'S EXPENSE BY A LANDLORD APPROVED WATERPROOFING CONSULTANT PER THE LANDLORD SPECIFICATIONS. ON COMPLETION OF INSTALLATION, TENANT SHALL OBTAIN AT THE TENANT'S EXPENSE, A SPECIAL INSPECTION SIGN- OFF FROM THE LANDLORD'S DESIGNATED ROOFING CONTRACTOR AND SHALL DELIVER PROOF OF SIGN -OFF TO THE LANDLORD TENANT COORDINATOR REPRESENTATIVE ON SITE. ELECTRICAL PANELS 1 : AS REQUIRED, PROVIDE LOCK -ON DEVICES ON PANEL CIRCUIT . BREAKERS FOR EXIT AND EMERGENCY LIGHT AND FIRE /SMOKE ALARM SYSTEM. 2 • FURNISH A COMPLETE TYPEWRITTEN IDENTIFICATION DIRECTORY CARD FOR ALL MAIN AND BRANCH CIRCUITS IN THE PANEL DOOR. MISCELLANEOUS ITEMS: 1 : DRY TYPE TRANSFORMER NOISE LEVEL IS LIMITED TO A MAXIMUM OF FIFTY (50) DB AVERAGE, MEASURED AT A DISTANCE OF ONE FOOT (1' -0 ") FORM THE CASE, PER NEMA PUBLICATION NO. TR- 1 -1960 OR LATEST REVISION. THEREOF. 2 • AS REQUIRED BY GOVERNING CODES, FURNISH SELF - CONTAINED, BATTERY PACK EMERGENCY LIGHTING AND EXIT SIGNS THROUGHOUT THE DEMISED PREMISES. 3 • PROVIDE WEATHERPROOF DISCONNECT SWITCH, 120 VOLT DUPLEX SERVICE OUTLET AT EACH ROOF- MOUNTED HVAC UNIT. 4 : ALL DEVICES AND EQUIPMENT IN FINISHED AREAS SHALL BE FLUSH MOUNTED, WHERE POSSIBLE. 5 • NO LIGHTING CAN BE INSTALLED OUTSIDE THE TENANT SPACE, IN THE COMMON AREA AND /OR CEILING FOR STOREFRONT LIGHTING OR SIGN ILLUMINATION. 6 : TENANT'S ELECTRICAL CONTRACTOR SHALL FURNISH AN IDENTIFICATION NAMEPLATE ON TENANT'S MAIN DISCONNECT SWITCH IN LANDLORD'S SWITCHBOARD. NAMEPLATES SHALL BE ONE- EIGHTH INCH (1/8 ") THICK PLASTIC, BLACK ON WHITE AND ETCHED LETTERS. THE MINIMUM SIZE SHALL BE ONE INCH (1") WITH ONLY THE TENANT'S SPACE NUMBER ENGRAVED ON SUCH, PERMANENTLY AFFIXED. 7 • TENANT SHALL PROVIDE AND INSTALL COMPLETE TELEPHONE SERVICE SUPPORT FACILITIES AS REQUIRED BY THE SERVING TELEPHONE COMPANY. ALL TENANT TELEPHONE EQUIPMENT IS TO BE CONTAINED WITHIN " INCH 3 4 EMPTY CONDUIT SHALL PROVIDE ONE THREE-QUARTER THE TENANTS S PACE. LANDLORD S (/ ) FROM LANDLORD'S TELEPHONE EQUIPMENT ROOM TO TENANT'S DEMISED SPACE. EXTENSION OF LANDLORD- PROVIDED CONDUIT TO TENANT'S TELEPHONE EQUIPMENT IS THE RESPONSIBILITY OF THE TENANT. TENANT SHALL MAKE APPLICATION TO THE SERVING TELEPHONE COMPANY FOR SERVICE AND SHALL COMPLY WITH THEIR REQUIREMENTS. TENANT'S TELEPHONE EQUIPMENT IS NOT PERMITTED IN LANDLORD'S TELEPHONE EQUIPMENT ROOM. 8 : TENANT'S HVAC SYSTEM SHALL BE POWERED OFF TENANT'S ELECTRICAL DISTRIBUTION SYSTEM. TENANT SHALL PROVIDE ALL POWER AND CONTROL WIRING, INCLUDING FINAL CONNECTION. 9 • TENANT'S LIGHTING AND LIGHTING CONTROL SYSTEM SHALL COMPLY WITH THE WASHINGTON STATe NON- RESIDENTIAL ENERGY CODE. FIRE ALARM SYSTEM LANDLORD SHALL FURNISH AND INSTALL ONE FIRE ALARM JUNCTION BOX INSIDE THE DEMISED PREMISES FOR EACH TENANT'S USE IN CONNECTING THEIR INDIVIDUAL FIRE ALARM SYSTEMS OR COMPONENTS. TENANT SHALL FURNISH AND INSTALL ALL NECESSARY INITIATION DEVICES, ANNUNCIATION DEVICES AND CONTROLS AS REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. THE TENANT SHALL CONTRACT WITH LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR FOR DESIGN AND PROGRAMMING. SYSTEM DESIGN A CENTRAL FIRE ALARM SYSTEM - COORDINATE SYSTEM MANUFACTURER AND MODEL WITH LANDLORD. • ALL NEW AND RELOCATING TENANTS SHALL BE CONNECTED TO AND SHALL COMPLY WITH ALL REQUIREMENTS OF LANDLORD'S NEW FIRE ALARM SYSTEM. LANDLORD WORK: LANDLORD SHALL PROVIDE A FIRE ALARM SYSTEM, AS FOLLOWS: • A CENTRAL ADDRESSABLE, VOICE EVACUATION TYPE, FIRE ALARM SYSTEM SERVING THE ENTIRE MALL. • LANDLORD WILL PROVIDE 'A RED FIRE ALARM JUNCTION BOX IN THE CORRIDOR WITH A 3/4" CONDUIT STUBBED INSIDE DEMISED TENANT SPACE FOR TENANT'S FIRE ALARM SYSTEM DEVICES. JUNCTION BOX WILL BE PROVIDED WITH FIRE ALARM ANNUNCIATION AND INITIATION CABLING AND TERMINAL BLOCKS. • LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO LANDLORD'S FIRE ALARM SYSTEM AT THE TENANT'S SOLE COST AND EXPENSE. TENANT WORK : GENERAL REQUIREMENTS 1 : TENANT SHALL INSTALL WITHIN TENANT'S PREMISES A FIRE ALARM SYSTEM OR COMPONENTS AS DELINEATED THROUGH DESIGN DOCUMENTS ISSUED BY LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR (AT TENANT'S EXPENSE). 2 : PROVIDE WIRING IN ACCORDANCE WITH NEC, NFPA AND AS REQUIRED BY LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR AND ANY LOCAL AUTHORITIES WHICH MAY HAVE JURISDICTION. 3 : THE TENANT SHALL FURNISH AND INSTALL DUCT DETECTOR(S) WITH REMOTE TEST SWITCH AND LED INDICATOR LIGHT IN EACH TENANT HVAC UNIT, IF REQUIRED BY CODE OR BY THE AUTHORITY HAVING JURISDICTION. 4 • ALL ZONES SHALL BE CLEARLY LABELED ON THE FIRE ALARM CONTROL PANEL. IF TENANT DEMISED PREMISES OCCUPIES TWO LEVELS, ZONES SHALL ALARM EACH LEVEL INDEPENDENTLY. 6 : THE TENANT SHALL USE ONLY LANDLORD DESIGNATED FIRE ALARM CONTRACTOR SPECIFIED EQUIPMENT TO ENSURE COMPATIBILITY WITH THE LANDLORD'S FIRE ALARM SYSTEM. FINAL TESTING OF FIRE ALARM SYSTEM PROGRAMMING AND TESTING OF THE DEVICES AND SEQUENCE OF OPERATION SHALL BE BY THE LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR AT THE TENANT'S EXPENSE. EACH TENANT'S FIRE ALARM SYSTEM SHALL BE FINAL TESTED BY THE LOCAL BUILDING AND FIRE MARSHAL AND WITNESSED BY LANDLORD'S ON -SITE REPRESENTATIVE. 16 TENANT DESIGN CRITERIA SCALE: N/A 10 12 13 14 15 16 17 18 19 20 21 22 PROVIDE PHONE JACK AT 5' -0" AFF AT LOCATION SHOWN. REVIEWED FOR 'CODE COMPLIANCE NE C J N 2 Pla City Of .Tukwila.:... SHOPPER TRACK SINGLE ORBIT 2 JUNCTION BOX. GENERAL CONTRACTOR SHALL PROVIDE (1) 1"c AND (1) CATEGORY 5 CABLE FROM JUNCTION BOX TO COMM. STRUCTURE. RJ JACK FOR SHOPPER TRACK TO BE ABOVE CEILING. VERIFY EXACT LOCATION OF SHOPPER TRACK JUNCTION BOXES AND CABLING REQUIREMENTS WITH GUESS PROJECT MANAGER PRIOR TO ROUGH -IN. EMBEDDED DOOR CONTACTS AND DOOR ALARM CONTACT MOUNTED ON HEAD OF DOOR FRAME WITH MAGNET MOUNTED IN TOP OF DOOR AT BACK OF HOUSE. PROVIDE JUNCTION BOX ABOVE CEILING WITH 1/2" CONDUIT STUBBED INTO HEAD OF DOOR FRAME. SENSORMATIC ALARM BOX MOUNTED ON THE CEILING. VERIFY AND COORDINATE EXACT LOCATION AND OTHER RELATED ELECTRICAL REQUIREMENTS WITH GUESS PROJECT MANAGER PRIOR TO ROUGH -IN. ALL CONDUIT SHALL BE HIDDEN FROM PUBLIC VIEW. PROVIDE 12 "X12 "X3/4" FIRE RATED PLYWOOD TELEPHONE BACKBOARD ABOVE IFS. PROVIDE #6 AWG GROUND WIRE TO SERVICE GROUND ELECTRODE. MOUNT GROUND TERMINAL AND RECEPTACLE AT UPPER LEFT HAND SIDE OF BACKBOARD. CONNECT THE GROUND WIRE TO THE BUILDING STEEL OR COLD WATER PIPE. SAW CUT FLOOR FOR INSTALLATION OF CONDUITS TO CASHWRAPS. PATCH FLOOR TO MATCH SURROUNDING FLOOR AREA. PRIOR TO SAW CUTTING, PERFORM FLOOR X- RAYING WITH LANDLORD PRIOR APPROVAL AND CONFIRM WITH LANDLORD SAW CUT LOCATION EXISTING UTILITIES. GENERAL CONTRACTOR TO RUN 1/2" CONDUIT WITH PULL STRING DOWN IN WALL FOR FLOOR MOUNTED SENSORMATIC UNITS. EXTEND CONDUIT UP TO CONTRLLER MOUNTED ABOVE CEILING. GENERAL CONTRACTOR TO COORDINATE WITH SENSORMATIC. JUNCTION BOX FOR RS -232 PLATE AT 6" AFF. PROVIDE POWER FOR FRONT CASHWRAP RECEPTACLE AND LIGHTS ROUTED FROM JUNCTION BOX CASHWRAP STUB UP. PROVIDE RECEPTACLES WITHIN CASEWORK AT LOCATIONS COORDINATED WITH CASEWORK CONTRACTOR. VERIFY CONDUIT ROUTING WITHIN CASEWORK, FIELD VERIFY EXACT FEED LOCATION FROM WALL. ROUTE CIRCUIT THROUGH AUTOMATIC TIME CLOCK CONTROLLED LIGHTING CONTACTOR. SEE AUTOMATIC CONTROLS DETAIL ON SHEET E3.0. PROVIDE (3) JUNCTION BOXES MOUNTED AT 39 1/2" AFF, 58 1/2" AFF, AND 77 1/2" AFF. PROVIDE (1) 20A, 1 PHASE, 120V GROUNDING TYPE RECEPTACLE HUBBLE #5362 AND FLUSH FLOOR BOX HUBBLE #B2422- (2)S3825. PROVIDE DUCT SMOKE DETECTOR AND CIRCUIT AS SHOWN. CONNECT TO FIRE ALARM SYSTEM AS REQUIRED. LO11 7 0 U N PROJECT TEAM: Architect: Epoch Design Group, Inc. 1 155 Olivette Exec. Pkwy. Suite 100 St. Louts, MO 63132 TEL: 314.721.1340 FAX: 314.721.0344 M. E. P. & F.P. Engineer: COPYRIGHT DISCLAIMER: THIS DOCUMENT IS THE PROPERTY OF EPOCH DESIGN GROUP, COPYRIGHTED AS DATED, ALL RIGHTS RESERVED. AUTHORIZATION FROM EPOCH DESIGN GROUP FOR USE OF THIS DOCUMENT I5 NOT TRANSFERABLE. THE REaPIENT OF THIS DOCUMENT 15 HEREBY ADVISED THAT IT I5 RELEASED FOR USE UNDER THE FOLLOWING TERMS AND CONDITIONS, THE DOCUMENT I5 FOR DESIGN INTENT AND INFORMATION ONLY, AND DOES all' AS -BUILT CONDITIONS. THE RECIPIENT RETAINS THE OBLIGATION TO VERIFY THE CONDITIONS OF THE SUBJECT PROPERTY AND TO COMPLETELY COORDINATE ALL DIMENSIONS, FABRICATION METHODS, RELATED AND INTEGRATED SYSTEMS, ETC, WITH RESPECT TO ALL ASPECTS OF THE WORK. EPOCH DESIGN GROUP MAKES NO WARRANTY AS TO THE SUITABILITY OF THE DOCUMENT FOR THE RECIPIENT'S INTENDED USE. THE RECIPIENT SPEaFICALLY AGREES TO WAIVE AND TO INDEMNIFY AND DEFEND ANY AND ALL aAIMS AGAINST EPOCH DESIGN GROUP, ITS CONSULTANTS, ANY OF ITS RELATED ENTITIES, VENDORS, OR CONTRACTORS, FOR ANY 1055 INCURRED AS A RESULT OF PROPE • E OF THIS DOCUMENT. THE RECIPIENT A TO�ETUR OR DES ' CFl{; S DOCUMENT UPON COM P,6IFORMED RJ H TLPROIECT. THE DOCUMENT I5 TO BE USED ONLY IN CONJUNCTION WITH THIS PROJECT. REUSE OF ANY PORTION OF THE DOCUMENT IN ANY OTHER CIRCUMSTANCE CONSTITUTES COPYRIGHT INFRINGEMENT, E irIf ES et ""Ll ' LJ `; PROJECT TITLE: 0% W Q 1 1) CO I— in w ll. 0 =�0 Z cv. W W v) 0 to 112 rn < 0 No.. Revision Description Date SHEET TITLE: ELECTRICAL POWER PLAN DRAWN BY: LBS ISSUE DATE: 11/07/07 o� — O Nt M M W LL • J o � 0. N LL u_ 1— RANDALL A. NELSON 8016 Reeder Rd. Lenexa, KS 66214 TEL, 913- 322 -5150 FAXI 913- 322 -5155 RECEIVED CITY OF TUKWILA DEC 1 1 2007 PErIIvI1 I CEI\ 1 ER 1— � (1) PROJECT NO.: SHEET NUMBER: 07073 E2.0 £LO17 7 U PROJECT TEAM: Architect: Epoch Design Group, Inc. 1 155 Olivette Exec. Pkwy. Suite 100 St. Louts, MO 63132 TEL 314.721.1340 FAX: 314.721.0344 M. E. P. & F.P. Engineer: COPYRIGHT DISCLAIMER: THIS DOCUMENT IS THE PROPERTY OF EPOCH DESIGN GROUP, COPYRIGHTED AS DATED, ALL RIGHTS RESERVED. AUTHORIZATION FROM EPOCH DESIGN GROUP FOR USE OF THIS DOCUMENT I5 NOT TRANSFERABLE. THE RECIPIENT OF THIS DOCUMENT I5 HEREBY ADVISED THAT IT IS RELEASED FOR USE UNDER THE FOLLOWING TERMS AND CONDITIONS: THE DOCUMENT I5 TO BE USED ONLY IN CONJUNCTION WITH THIS PROTECT. REUSE OF ANY PORTION OF THE DOCUMENT IN ANY OTHER CIRCUMSTANCE CONSTITUTES COPYRIGHT INFRINGEMENT. THE DOCUMENT I5 FOR DESIGN INTENT AND INFORMATION ONLY, AND DOES NOT CONSTITUTE AS•BUILT CONDITIONS. THE RECIPIENT RETAINS THE OBLIGATION TO VERIFY THE CONDITIONS OF THE SUBJECT PROPERTY AND TO COMPLETELY COORDINATE ALL DIMENSIONS, FABRICATION METHODS, RELATED AND INTEGRATED SYSTEMS, ETC, WITH RESPECT TO ALL ASPECTS OF THE WORK. EPOCH DESIGN GROUP MAIDS NO WARRANTY AS TO THE SUITABILITY OF THE DOCUMENT FOR THE RECIPIENTS INTENDED USE. THE RECIPIENT SPEOFICMLY AGREES TO WAIVE AND TO INDEMNIFY AND DEFEND ANY AND ALL CLAMS AGAINST EPOCH DESIGN GROUP, ITS CONSULTANTS, ANY OF ITS RELATED ENTITIES, VENDORS, OR CONTRACTORS, FOR ANY LOSS INCURRED AS A RESULT OF PROPER OR IMPR• ER LASE OF THIS DOCUMENT. THE RECIPIENT AGRE UPON COMPLET PROF 434_-8 1 °NAL ate K Wgrar EXPlikS PROJECT TITLE: cf) ci) w No.Q Revision Description Date SHEET TITLE: ELECTRICAL DETAILS DRAWN BY: LBS ISSUE DATE: 11/07/07 lv RANDALI A. NELSON 8016 Reeder Rd. Lenexa, KS 66214 TEL, 913- 322 -5150 FAX: 913- 322 -5155 RECEIVED CITY OF TUKWILA DEC 1 1 2007 PEhivn CEO,! 1 ER PROJECT NO.: SHEET NUMBER: 07073 E3.O TELEPHONE: 314721.1 340 FACSIMILE: 314.721.0344 CONTROLLER ELECTRICIAN TO INSTALL JUNCTION BOX ABOVE CEILING WITHIN 5 FEET OF ELECTRICAL CAP BOARD ENCLOSURE, I.G. CIRCUIT. ENCLOSURE 1" CONDUIT TO COMM. STRUCTURE C k O P LP -6 TRACK LP -7 SALES AREA 1 2 L - 9 OUTLET ACCESS POINT LIGHTING LP CONTACTORS LC2 SALES AREA TRACK -10 LC2 LC3 LP -11 SALES AREA RUN CONDUIT WITHIN STOCKROOM CEILING STOCK ROOM SIDE OF THE WALL LP -12 LP TRACK AREA -13 SALES OVERRIDE TOGGLE SWITCHES WITHIN SIGHT OF LOAD BEING CONTROLLED o - I 0 Q0 LP -15 SALES AREA LP -17 SALES AREA LP -19 SALES AREA \ O k1 CEILING LINE (BOTTOM OF JOISTS) LP -22 DISPLAY LIGHT LP -24 DISPLAY LIGHT DISPLAY LIGHT Q ©P � Q ©P LP -26 LP -4 \ LIGHTING STOCK AREA ■ LP -1 \ LIGHTING SIGNAGE LP -30 DISPLAY LIGHT LP -15 SALES AREA •; RE ALARM TO BE LOCATED TO SALES FLOOR LP -3 SHOW WINDOW LP -17 SALES AREA AT CEILING (FINISHED) LOCATE RS -232 PLATE ON FACE OF PLATFORM (TOEKICK) LP -5 SHOW WINDOW LP -20 CONTACTORS LC3 DRESSING ROOM AREA CONTACTORS LC1 I 7 1 1 COORDINATE LOCATION WITH THE ARCHITECT AND SEE THE ARCHITECTURAL DRAWING. 7 GC TO CUT 3" DIA HOLE COORD WITH OWNER'S REP o o -0 TORK TIMECLOCK SEE ARCH PLANS +� Q ee . `• y LC1 - STOREFRONT AND SIGN LC2 - SALES AREA LIGHTS NEEDS LC3 - MERCHANDISING LIGHTS NEED NEED TO BE SET PER TO BE SET TO TURN ON 30 TO BE SET TO TURN ON 2 LANDLORD REQUIRED TIME. MIN, BEFORE STORE OPENS HOURS BEFORE STORE AND 30 MIN. AFTER STORE OPENS AND 2 HOURS AFTER CLOSES. STORE CLOSES. (2) IN -FLOOR ANTENNAS (TERMINATE CONDUIT AT CENTER OF FLOOR) VERIFY ALL SPECIFICATIONS WITH TO SENSORMATIC SUPPLIER PRIOR TO INSTALLATION CONTACT ED ENGLAND 0 (800) 279 -1442 ELECTRICAL (SENSORMATIC NOTES) - THE AC SOURCE MUST BE A 3 -WIRE, 24 HOUR UNSWITCHED OUTLET WITH LESS THAN 0.5 VAC BETWEEN NEUTRAL AND GROUND. - DO NOT SHARE THE AC SOURCE WITH NEON SIGNS, MOTORS, COMPUTERS, CASH REGISTER, TERMINALS OR DATA COMMUNICATIONS EQUIPMENT. - DO NOT USE ORANGE - COLORED OUTLETS DEDICATED FOR COMPUTER EQUIPMENT. 1 RUN 1" CONDUIT W /PULL STRING FROM J -BOX ABOVE SALES /STOCK DOOR TO COMMUNICATION STRUCTURE. 2 ACCESS POINT: GENERAL CONTRACTOR TO PROVIDE AND INSTALL in DEDICATED CIRCUIT 20AMP /110VOLT J -BOX & DUPLEX RECEPTACLE FOR ACCESS POINT DIRECTLY ABOVE THE DOOR FROM CORRIDOR TO RETAIL FLOOR ON THE CORRIDOR SIDE (SEE POWER PLAN). RUN 1" CONDUIT TO COMM. STRUCTURE. 5 AUTOMATIC CONTROLS DETAIL SCALE: N/A ;.; 0 0 3 GENERAL CONTRACTOR TO PROVIDE 20A DOUBLE DUPLEX RECEPTACLE _ BUZZER PUSH BUTTON EDWARDS #15-3E1 AT OUTSIDE OF REAR # � — TO ELECTRICAL PANEL O CONNECT TO THE NEAREST AVAILABLE POWER ISOLATED GROUND, ON DEDICATED CIRCUIT - ORANGE COLOR -FOR BACK OFFICE PC. j I y 4 UPS UNIT FOR COMPUTER. (BY OTHERS) RUN 1" CONDUIT W /PULL STING FROM MANAGERS DESK TO DOOR MTD AT 48" A.F.F. �•-� a TAP _ 5 6V T COMMON 4 PORTS (2) DATA (2) VOICE TO —6 �� TRANSFORMER 3 4 COMM STRUCT TELEPHONE BOARD FOR FAX AND PHONE. PHONE JACK AT 42" ( ) 6 UNDER COUNTER FLOURESCENT LIGHT FIXTURE WITH SWITCH, SEE EDWARDS BUZZER #725 ABOVE STOCK CEILING I IN STOCKROOM "C. LIGHTING FIXTURE SCHEDULE. PROVIDE FLEX CONDUIT TO HARD WIRE FIXTURE IN WALL BEHIND UPPER CABINET. o #14 CU IN 3/4 TYPICAL EDWARDS BUZZER #725 r 7 QUAD RECEPTACLE. WITHIN CASH WRAP COORD CHIME PUSH BUTTON EDWARDS #15 -3E1 MTD W /IN CASH WRAP -- COORD LOC /W LOC /W OWNER'S REP. — TO ELECTRICAL PANEL OR CONNECT TO THE 8 SENSORMATIC ELEVATION 7 / STOCK ROOM DETAILS SCALE: N/A SCALE: N/A �'"•`�`� CO g p . �W y p COMPLIANCE NFPA ® of OJ NEC , '7 6mC H 2 ai y �ib — 2 12" X 12" PLYWOOD MOUNTED OWNER'S REP. NEAREST AVAILABLE POWER BB��BB T o CHIME IN Tr"-TT''''''----TRANSFORMER STOCKROOM CEILING OPERATIONAL NOTE: I TO WALL "li Ll6U V/1 1 r City Of Tukwila T Tr..... fr fi fi fri I CONDUIT TO TOP OF COM STRUCTURE BY E.C. BUZZER RINGS AT CASHWRAP AND IN STOCKROOM FROM REAR DOOR. CHIME RINGS IN STOCKROOM FROM CACHWRAP. I 1 BUZZER AND CHIME SCHEMATIC GUESS COMMUNICATION STRUCTURE NOTES: 1. FULL LENGTH FRONT DOOR 2. INSTALL 3 HINGES ON FRONT DOOR FOR STABILITY 3. FRONT DOOR TO BE VENTED AT TOP & BOTTOM 4. INSTALL (2) - 1" WIDE X 2" DEEP PANDUIT WIRE CHANNELS AS INDICATED ON DRAWINGS 5, INSTALL (1) - 4' 15 AMP WIRE MOLD POWER STRIP AS INDICATED ON DRAWINGS. PLUG INTO ONE OF (3) 15 AMP SURGE SUPPRESS RECEPTACLES. ' 6. INSTALL 84' DATA EQUIPMENT RACK AS INDICATED ON DRAWINGS 7. IN (3) EQUIPMENT SHELVES AS INDICATED ON DRAWINGS 8. MANUFACTURE & INSTALL 1/4' 19" X 15.75" ALUMINUM BACK PANE. FOR SECURITY SYSTEM AS INDICATED 01 DRAWINGS 9. MANUFACTURE ;TALL 1/4" X 19" X 19.25" ALUMINUM BACK FOR TELEPHONE SYSTEM AS INDICATED ON DRAWINGS EACH ON ITS OWN 'I Ip ° ° °I of ° 8 o o 8 : e Q „, - 0 - ° ° OI1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 - TELEPHONE SYSTEM INSTALLED BY GUESS VENDOR MOUNTED CUTLER H CUTLER-HAMMER N VB AX K PAN BY 1 H - UNINTERRUPTIBLE POWER SI ILY BY GUESS VENDOR - EQUIPMENT XIPM SHELF BY CUTLER-HAMMER 17.75" -CROWN CTS -600 POWER Al A! -1ER 19" W X 5.25" H - SHURE SCM2�� MIXER 19 X 1.75 H - DMX PROF PLAYER 19 X 3.5" H - EQUIPMENT BY CUTLI -I AMMER 17.75" W X 10" 1 (INVERTED) TELEPHONE SYSTEM (COMMSYS)BACK PANEL " 19.25” H SUPPLIED BY CUTLER - HAMMER SCALE: N/A _ _ CATS CABLE (IN CONDUIT) P.O.S. CONTROLLER OR IN STORE PROCESSOR C I 1 I ORBIT STORE TELEPHONE ° ° o -- ❑ 1-1. _ ® ® ® ® -- 1 ® ® ® ® ® ® ® ® ® ® ® 1 - STOR MUSIC 0 o g UPS INSTALLED BY OTHERS STORE POS 11 - - ON I SINGLE ORBIT 2 \ ° SEE ARCHITECTURAL FOR MOUNTING COMMUNICATION WORK: 1. FOR SINGLE ORBIT 2 INSTALLATIONS, A CATEGORY 5 CABLE MUST BE RUN FROM THE STORE CONTROLLER /SP TO THE FRONT DOOR (MAIN CUSTOMER ENTRANCE). IF A STORE HAS MULTIPLE CONTROLLERS. PLEASE CALL SHOPPER TRAK OR THE CLIENTS STORES SYSTEMS GROUP TO DETERMINE WHICH ONE WILL BE USED. 2. PROVIDE 15' -20' OF CABLE COILED UP AT EACH END OF THE RUN. AT THE FRONT DOOR LEAVE THE CABLE COIL IN A LOCATION THAT CAN BE REACHED USING AN 8' LADDER. GENERAL CONTRACTOR NOTES: 1. THE ORBIT 2 UNIT WILL BE INSTALLED CENTERED ABOVE THE DOORWAY. THE DISTANCE IN FROM THE DOORWAY WILL VARY DEPENDING ON WHETHER OR NOT THERE IS A DOOR THAT USED DURING THE DAY, AND WHICH DIRECTION THE DOOR SWINGS: A. IF THERE IS NO DOOR AT THE DOORWAY, OR THE DOORS WILL BE PROPPED OPEN DURING THE DAY THE ORBIT 2 WILL BE MOUNTED 6 " -12" INSIDE OF THE DOORWAY. B. IF THERE IS A DOOR THAT SWINGS OUT, THE ORBIT 2 WILL BE MOUNTED 12 " -18" INSIDE THE DOORWAY. C. IF THERE IS A DOOR THAT SWINGS IN, THE ORBIT 2 WILL BE MOUNTED 4 " -6" IN FROM THE FURTHEST IN -SWING OF THE DOOR. 2. IF THE CEILING /SOFIT IS 15' AFF OR LESS AT THE MOUNTING LOCATION SPECIFIED ABOVE, ORBIT 2 WILL BE ATTACHED DIRECTLY TO THE CEILING. FOR CEILING /SOFFITS HIGHER THAN 15', SHOPPER TRAK WILL INSTALL A MOUNTING BRACKET THAT ATTACHES TO THE WALL ABOVE THE DOOR THAT WILL SUPPORT THE ORBIT AND POSITION TH UNIT 6 " -18" INTO THE STORE. THE MOUNTING BRACKET WILL GENERALLY BE INSTALLED AT 12" AFF, UNLESS CONSTRUCTION CONDITIONS PREVENT THIS, 3. IF THE CEILING HEIGHT IS GREATER THAN 15' AFF, AND THE UNIT CANNOT BE MOUNTED BELOW 15' USING A BRACKET ATTACHED TO THE WALL ABOVE THE DOOR BECAUSE OF A CONTINUOUS, MULLION -FREE GLAZING, OR AN OPENING THAT EXTENDS TO THE CEILING, AN ORBIT WITH A SPECIAL TELEPHOTO LENS WILL BE INSTALLED AT THE CEILING LEVEL. THE TELEPHOTO LENS IS NOT EFFECTIVE ABOVE 30' AFF. 4. IF THE STORE HAS A VESTIBULE, THE ORBIT WILL BE MOUNTED INSIDE OF THE STORE ITSELF, RATHER THAN IN THE VESTIBULE. 5. IF THE STORE WILL HAVE A HARD (PLASTER OR GYPSUM BOARD) CEILING, INSTALL A JUNCTION BOX 1"-2" AWAY FROM THE RECOMMENDED ORBIT LOCATION SPECIFIED ABOVE. 6. PROVIDE 1" CONDUIT W /PULL STRING FROM THE COMMUNICATIONS STRUCTURE TO A LOCATION ABOVE ENTRY SOFFIT. LOOP CONDUIT TO OTHER DOORS AS REQUIRED. STORE ALARM O o g g 8 v ° PLEASE NOTE THAT THIS SHELF HAS BEEN INVERTED, t = 1 �E • �•„ e • ' --- •• o g ° °' ° I to 01 P m) 0 0 1 g a e g % g o g O % 8 ° 1 QUIPMENT SHELF o 0 a - CIRCUIT AT BASE STRUCTURE AS INDICATED ON = 24 PORT 1 PANEL BY VENDOR - DRAWINGS 10. INSTALL BARRIER ELECTRICAL & COMMUNICATION S 1 1 • LABEL DOOR E NT INSTALLED IMPORTANT NOTE: rn ` -'- - - -- - -� ENET REG G 2 REG BOPC, ACCESS POINT, 56K U ;MANAGER BY POS VENDOR - US ROBOTIC`. - IM HUB BY P05 VENDOR - CISCO ROUTE — LANTRONIX S ,K GUESS VENDOR - EQUIPMENT CUTLER-HAMMER JAMMER 17.75 W X 10" D - SECURITY SYSTEM BY ADT (LOCATE TO RIGHT SIDE OF BACK PANEL) MOUNTED ON BACK PANEL BY CUTLER- HAMMER 19" W X 15.75" H _ (3) - 15 AMP CIRCUITS WITH SURGE SUPPRESS RECEPT INSTALLED BY CUTLER - HAMMER 8 8 % O i�L I Iu ICI ..,....... IARTRORIRBHOPPERTMat [ i g g o e ° ° o o ° ° ° o o o Q uc■ I t )o o I MX AND ADT SHALL E NUMBER TWO, FAILURE TO COMPI REQUIREMENT SHALL BE CORRECTED BY VENDOR NO COST TO OWNER. _ . I - I �-- of LOCATION. Q '•7t �`1 I p ; s ° s `s O o o s • • • ADT SECURITY SYSTEM CONTROL BOX INSTALLED BY OTHERS 12.5 WIDE X14.5 HIGH X3 DEEP • ° 1 0ew eoe pee Doe ew ow ew Doe 7 t eeo 0 ADT EQUIPMENT PANEL INSTALLED BY CUTLER - HAMMER BACK PANEL 19" W X 15.75" H • F - - Q °i . ° ° a I II 21" \ \ "- "— 26" 26 - -10 2 O SHOPPER TRACK DETAIL p o COMMUNICATION STRUCTURE DETAIL SCALE: N/A SCALE: N/A £LO17 7 U PROJECT TEAM: Architect: Epoch Design Group, Inc. 1 155 Olivette Exec. Pkwy. Suite 100 St. Louts, MO 63132 TEL 314.721.1340 FAX: 314.721.0344 M. E. P. & F.P. Engineer: COPYRIGHT DISCLAIMER: THIS DOCUMENT IS THE PROPERTY OF EPOCH DESIGN GROUP, COPYRIGHTED AS DATED, ALL RIGHTS RESERVED. AUTHORIZATION FROM EPOCH DESIGN GROUP FOR USE OF THIS DOCUMENT I5 NOT TRANSFERABLE. THE RECIPIENT OF THIS DOCUMENT I5 HEREBY ADVISED THAT IT IS RELEASED FOR USE UNDER THE FOLLOWING TERMS AND CONDITIONS: THE DOCUMENT I5 TO BE USED ONLY IN CONJUNCTION WITH THIS PROTECT. REUSE OF ANY PORTION OF THE DOCUMENT IN ANY OTHER CIRCUMSTANCE CONSTITUTES COPYRIGHT INFRINGEMENT. THE DOCUMENT I5 FOR DESIGN INTENT AND INFORMATION ONLY, AND DOES NOT CONSTITUTE AS•BUILT CONDITIONS. THE RECIPIENT RETAINS THE OBLIGATION TO VERIFY THE CONDITIONS OF THE SUBJECT PROPERTY AND TO COMPLETELY COORDINATE ALL DIMENSIONS, FABRICATION METHODS, RELATED AND INTEGRATED SYSTEMS, ETC, WITH RESPECT TO ALL ASPECTS OF THE WORK. EPOCH DESIGN GROUP MAIDS NO WARRANTY AS TO THE SUITABILITY OF THE DOCUMENT FOR THE RECIPIENTS INTENDED USE. THE RECIPIENT SPEOFICMLY AGREES TO WAIVE AND TO INDEMNIFY AND DEFEND ANY AND ALL CLAMS AGAINST EPOCH DESIGN GROUP, ITS CONSULTANTS, ANY OF ITS RELATED ENTITIES, VENDORS, OR CONTRACTORS, FOR ANY LOSS INCURRED AS A RESULT OF PROPER OR IMPR• ER LASE OF THIS DOCUMENT. THE RECIPIENT AGRE UPON COMPLET PROF 434_-8 1 °NAL ate K Wgrar EXPlikS PROJECT TITLE: cf) ci) w No.Q Revision Description Date SHEET TITLE: ELECTRICAL DETAILS DRAWN BY: LBS ISSUE DATE: 11/07/07 lv RANDALI A. NELSON 8016 Reeder Rd. Lenexa, KS 66214 TEL, 913- 322 -5150 FAX: 913- 322 -5155 RECEIVED CITY OF TUKWILA DEC 1 1 2007 PEhivn CEO,! 1 ER PROJECT NO.: SHEET NUMBER: 07073 E3.O TELEPHONE: 314721.1 340 FACSIMILE: 314.721.0344 PANELBOARD PP BUS AMPS: 225A LOCATION: STOCK ROOM GROUND BUS: YES MAIN SIZE / TYPE: 150A MCB NEMA RATING: NEMA 1 ISOL. GROUND BUS: NP VOLTS / PHASE: 280Y/120V, 3PH, 4W AFC VALUE: VERIFY FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: VERIFY SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # P AMPS A 8 f C AMPS P 1 SPARE 20 1 1,200 1 0 0 250 1 0 1 2 1 20 SPARE 2 12 1 1,380 20 S 180 12 1 20 POS 4 3 MICROWAVE 20 1 12 1,200 1,506 9 980 180 12 1 20 POS 6 I 5 REFRIGERATOR 20 1 12 800 580 7 S 180 12 1 20 POS 8 I 7 COMMUNICATIONS STRUCTURE 20 1 12 400 SALES AREA LTG 2 760 1 1 360 12 1 20 POS RCPT 10 9 COMMUNICATIONS STRUCTURE 20 1 12 400 TRACK LTG 1 12 760 360 360 12 12 1 1 20 20 POS RCPT POS RCPT 12 14 11 COMMUNICATIONS STRUCTURE 20 1 12 400 760 630 6 0 1 13 TTB /TC 20 1 12 400 SALES AREA LTG 2 380 ! 200 12 1 20 BUZZER 16 15 RESTROOM RCPT 20 1 12 180 C 750 0 1 20 SPARE 18 17 INSTANTANEOUS WATER HEATERS 20 1 12 750 800 0 1 20 SPARE 20 19 MANAGER'S DESK 20 1 12 800 560 200 12 1 20 RF ANTENNA 22 21 MANAGER'S DESK 20 1 12 360 740 380 12 1 20 ALARM PAD 24 23 MANAGER'S DESK 20 1 12 360 360 0 1 20 SPARE 26 25 SALES FLOOR RCPT 20 1 12 360 540 0 1 20 SPARE 28 27 SALES FLOOR RCPT 20 1 12 540 800 0 1 20 SPARE 30 29 SENSORMATIC 20 1 12 800 200 0 SPACE 32 31 FIRE ALARM PANEL 20 1 12 200 0 0 SPACE 34 33 SPARE 20 1 0 200 0 6,232 - SPACE PANELBOARD 'LP' 36 38 35 DUCT SMOKE DETECTORS 20 1 12 200 6,232 37 SPARE 20 1 0 40 6,288 6,288 4 3 70 39 SPARE 20 1 0 42 6,465 6,465 - 41 SPARE 20 1 0 PER PHASE SUB - TOTALS 8,932 1 9,908 1 10,695 1 LEGEND: TOTAL CONNECTED PANELBOARD (VA) TOTAL CONNECTED PANELBOARD (AMPS) TOTAL PANELBOARD DEMAND (VA) TOTAL PANELBOARD DEMAND (AMPS) 19,627 . TS - VIA TIME SWITCH ST - SHUNT TRIP GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND EM - EMERGENCY LTG. / LOCKING TAB 70 33,528 120 EX - EXISTING TO REMAIN PANELBOARD LP BUS AMPS: 225A LOCATION: STOCK ROOM GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 ISOL. GROUND BUS: NO VOLTS / PHASE: 208Y/120V, 3PH, 4W AFC VALUE: VERIFY FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: VERIFY SECTIONS: 1 OF 1 CKT C CIRCUIT B BREAKER W WIRE L LOAD C CONNECTED PER PHASE (VA) L LOAD W WIRE B BREAKER C CIRCUIT C CKT P AMPS D A B B C ( AMPS P P S 1 S SIGNAGE 2 20 1 1 1 12 1 1,200 1 1,450 2 250 1 12 1 1 2 20 E EMERGENCY / EXIT / NIGHT LTG 2 2 356 1 12 1 1 2 20 S STOCK ROOM /EM LTG 4 4 3 S SHOW WINDOW LTG / RCPT 2 20 1 1 1 12 6 609 9 965 3 1,506 9 936 1 12 1 1 2 20 T TRACK LTG 6 6 5 S SHOW WINDOW LTG / RCPT 2 20 1 1 1 12 5 570 1 1,706 9 7 S SALES AREA LTG 2 20 1 1 1 12 7 770 1 1,404 1 12 1 1 2 20 T TRACK LTG 1 10 9 S SALES AREA LTG 2 20 1 1 1 12 7 700 . . 2,104 • • 1 2,034 1 1,404 1 12 1 1 2 20 T TRACK LTG 1 12 11 S SALES AREA LTG 2 20 1 1 1 12 6 630 2 630 0 13 S SALES AREA LTG 2 20 1 1 1 12 6 630 6 0 1 12 1 1 2 20 S SPARE 1 16 15 S SALES AREA LTG 2 20 1 1 1 12 8 819 8 819 0 PANELBOARD HP BUS AMPS: 225A LOCATION: STOCK ROOM GROUND BUS: YES MAIN SIZE / TYPE: 125A MCB NEMA RATING: NEMA 1 ISOL. GROUND BUS: NO VOLTS /PHASE: 480Y/277V, 3PH, 4W AFC VALUE: VERIFY FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: VERIFY SECTIONS: 1 OF 1 CKT CIRCUIT BREAKER WIRE LOAD CONNECTED PER PHASE VA LOAD WIRE BREAKER CIRCUIT CKT # DESCRIPTION AMPS P SIZE (VA) A I B PHASE (VA) SIZE P AMPS DESCRIPTION # 1 PANELBOARD 'PP' VIA - 8,932 13,932 5,000 - 2 3 TRANSFORMER 'Tt' 60 3 6 9,908 16,238 6,330 10 3 30 VAV -1 4 5 - 10,695 15,695 5,000 - 6 7 SPACE 20 1 0 443 443 12 1 15 VAV -2 8 9 SPACE 20 1 0 0 ! 0 1 20 SPARE 10 11 SPACE 20 1 0 l 0 0 1 20 SPARE 12 13 SPACE 20 1 0 0 0 1 20 SPACE 14 15 SPACE 20 1 0 0 f 0 1 20 SPACE 16 17 SPACE 20 1 0 I 0 0 1 20 SPACE 18 19 SPACE 20 1 0 0 1 0 1 20 SPACE 20 PER PHASE SUB - TOTALS 1 14,375 1 16,238 I 15,695 1 LEGEND: TOTAL CONNECTED PANELBOARD (VA) 46,308 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 56 GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 50,301 FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 61 EM - EMERGENCY LTG. / LOCKING TAB OL - RE: ONE -LINE DIAGRAM 20 A B C NEUTRAL GROUND BLACK RED BLUE WHITE GREEN NOTE: MANUFACTURERS' NAMES ON WHICH THE SPECIFICATION IS BASED INDICATE THE MINIMUM QUALITY OF PRODUCT REQUIRED. SUBSTITUTION MAY BE MADE TO THOSE SPECIFIED IF DEEMED EQUIVALENT BY THE OWNER'S REPRESENTATIVE. ALL WORK AND PRODUCTS SHALL MEET THE REQUIREMENTS OF THE LANDLORD. 1. THE GENERAL CONDITIONS AND SUPPLEMENTARY GENERAL CONDITIONS SHALL BE CONSIDERED AS PART OF THIS SPECIFICATION. 2. CONTRACTORS SHALL VISIT SITE PRIOR TO BIDDING. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS. FIELD VERIFY LANDLORD'S ELECTRICAL AND TELEPHONE EQUIPMENT AND DISTANCE FROM LEASED SPACE. NO CLAIMS FOR EXTRAS RESULTING FROM LACK OF KNOWLEDGE OF EXISTING SITE CONDITIONS SHALL BE APPROVED. 3. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. ALL MATERIALS AND EQUIPMENT SHALL BE COMMERCIAL GRADE AND SHALL CARRY A U.L. LABEL. MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING COMPONENTS THEREOF SHALL BE NEW AND SUCH AS APPEARS ON THE UNDERWRITER'S LABORATORY LIST OF APPROVED ITEMS AND SHALL MEET THE REQUIREMENTS OF RECOGNIZED STANDARDS. EQUIPMENT SHALL BE SIZED IN CONFORMITY WITH REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AND OTHER APPLICABLE CODES. 4. THE WORD "PROVIDE" AS USED HEREIN MEANS TO FURNISH AND INSTALL COMPLETE. 5. ALL WORK TO BE IN ACCORDANCE WITH NEC AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES. 6. CONTRACTOR SHALL BE RESPONSIBLE TO COMPLETE ALL FORMS REQUIRED TO SECURE AND PAY FOR ALL REQUIRED PERMITS AND INSPECTION CERTIFICATES. 7. SUBMIT MATERIAL LISTS AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE ARCHITECT FOR APPROVAL. SUBMITTALS SHALL BE IN ACCORDANCE WITH GENERAL CONDITIONS AND SHALL BEAR THE STAMP OF THE ELECTRICAL CONTRACTOR SHOWING THAT HE HAS REVIEWED AND APPROVED THEM. LACK OF SUCH CONTRACTOR'S APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY THE ARCHITECT. 8. SCOPE OF WORK: PROVIDE ELECTRICAL SERVICE TO SPACE PER DRAWINGS AND LANDLORDS REQUIREMENTS. INSTALL NEW LIGHTING FIXTURES, PER SCHEDULE. NEW RECEPTACLES AS INDICATED. IF APPLICABLE, CIRCUITING OF RELOCATED PANEL(S). PROVIDE NEW CIRCUIT BREAKERS AS REQUIRED. RELOCATE TRANSFORMER. PROVIDE TELEPHONE SERVICE AND TELEPHONE SYSTEM RACEWAY AND JUNCTION BOXES. ALL TELEPHONE SYSTEM WIRING AND DEVICES WITHIN TENANT SPACE FURNISHED AND INSTALLED BY OWNER. TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION. TESTING OF ALL ELECTRICAL EQUIPMENT. PROVISION FOR TEMPORARY CONSTRUCTION POWER. 9. CONDUIT SHALL BE STANDARD STEEL, RIGID IMC OR EMT (THIN WALL). CONDUIT SHALL BE CONCEALED IN FINISHED AREAS. EXCEPT AS OTHERWISE APPROVED BY LANDLORD'S REPRESENTATIVE. EMT CONNECTIONS SHALL BE COMPRESSION TYPE. MINIMUM SIZES OF CONDUIT SHALL BE 3/4" EXCEPT 1/2" FOR SWITCH LEGS. EMT SHALL BE GALVANIZED OR ELECTRO- GALVANIZED. EMT SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS RUN ABOVE SUSPENDED CEILINGS OR CONCEALED IN INTERIOR PARTITIONS. EMT SHALL NOT BE CONCEALED IN POURED CONCRETE FLOOR OR WALLS. USE HEAVY WALL CONDUIT OR IMC FOR UNDER SLAB INSTALLATIONS. IMC IS PERMITTED WITH SCREW CONNECTIONS. FLEXIBLE METAL CONDUIT MAY BE USED ONLY FOR SHORT CONNECTIONS TO FIXTURES AND EQUIPMENT, AS PERMITTED BY CODE. MAXIMUM LENGTH 5' -0 ". 10. ALL CONDUCTORS SHALL BE SOFT DRAWN, ANNEALED COPPER, WITH 600V INSULATION: #10 AND SMALLER -SOLID WITH SINGLE BRAID. #8 AND LARGER- STRANDED WITH AT LEAST DOUBLE BRAID. ALL WIRING TO BE 2 #12, UNLESS OTHERWISE NOTED. #14 MAY BE USED FOR CONTROL APPLICATIONS. ALL LOW VOLTAGE WIRING NOT REQUIRED TO BE IN CONDUIT SHALL BE FIRE RETARDANT PLENUM RATED. ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. GENERAL WIRING SHALL HAVE (75' C) THW AND THWN OR (90' C) THHN INSULATION. ALUMINUM CONDUCTORS ARE NOT PERMITTED. WIRE CONNECTORS SHALL BE EQUAL TO SCOTCHLOCK FOR #8 AND SMALLER, AND T &B "LOCK -TITE" FOR #6 AND LARGER. WIRES SHALL BE COLOR CODED AND FOLLOWED THROUGHOUT FOR FEEDERS AND BRANCH CIRCUITS AND USED AS A BASIS FOR BALANCING LOADS: USE 10 AWG (MINIMUM) CONDUCTORS FOR 20 AMPERE, 120 VOLT BRANCH CIRCUITS LONGER THAN 75 FEET. USE 10 AWG (MINIMUM) CONDUCTORS FOR THAN 150 FEET. 120/208 Y VOLTS PHASE COLOR 20 AMPERE, 277 VOLT BRANCH CIRCUITS LONGER 277/480 Y VOLTS PHASE COLOR A YELLOW B BROWN C ORANGE NEUTRAL WHITE W /TRACER OR GRAY GROUND GREEN 11. BOXES AND FITTINGS: BOXES AND FITTINGS SHALL BE NEW, TOP QUALITY AND LOCATED WHERE REQUIRED TO INSTALL THE CONDUCTORS IN COMPLIANCE WITH THE PREVAILING CODES. APPROVED MANUFACTURES ARE: STEEL CITY, RACO OR APPLETON. SHEET METAL BOXES: NEMA OS 1. CAST METAL BOXES: NEMA FB 1, TYPE FS OR FD, CAST FERROALLOY BOX WITH GASKETED COVER. BOXES IN FIRE -RATED WALLS SHALL HAVE A FIRE RATING EQUAL TO OR GREATER THAN THE RATING OF THE WALL. 12. WIRING DEVICES: WALL SWITCHES, SINGLE POLE, DOUBLE POLE, AND THREE WAY SHALL BE SPEC. GRADE, 20A, 120/277V, WITH SCREW TERMINALS, EQUAL TO HUBBELL #HBL1221. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR OR LEVITON. GENERAL DUTY DUPLEX RECEPTACLES SHALL BE 2 -POLE, 3 -WIRE GROUNDING TYPE, COMMERCIAL GRADE, 20A, 125V EQUAL TO HUBBELL #5362. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR, OR LEVITON. GROUND FAULT INTERRUPTER RECEPTACLE SHALL BE, DUPLEX RECEPTACLES, FEED - THROUGH TYPE, CAPABLE OF PROTECTING CONNECTED DOWNSTREAM RECEPTACLES ON A SINGLE CIRCUIT, 20A, 120V, 60 HZ; WITH SOLID -STATE GROUND FAULT SENSING AND SIGNALING; WITH 5 MILLIAMPERES GROUND -FAULT TRIP LEVEL EQUAL TO HUBBELL #GF5362. APPROVED MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR, OR LEVITON. WEATHERPROOF RECEPTACLE COVER SHALL BE HUBBELL #WP826MP. APPROVED MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR, OR LEVITON. DEDICATED DUPLEX RECEPTACLES SHALL BE RED, 2 -POLE, 3 -WIRE 20A, 125V, STRAIGHT BLADE DEVICE WITH DEDICATED GROUND CONNECTION, EQUAL TO HUBBELL #5362 -R. APPROVED MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR, OR LEVITON. WIRING DEVICE ACCESSORIES INCLUDING ALL WALL PLATES SHALL BE PROVIDED AT EACH DEVICE. WALL PLATES SHALL BE SAME COLOR AS DEVICE AND MANUFACTURED AS A ICAL SPECIFICATIONS COMPANION TO THE DEVICE. ALL WIRING DEVICES AND COVERPLATES SHALL BE WHITE UNLESS NOTED OTHERWISE. MOUNTING HEIGHTS OF DEVICES SHALL BE TO THE FOLLOWING CENTERLINES, UNLESS NOTED OTHERWISE: TOGGLE SWITCHES RECEPTACLES TELEPHONE OUTLETS DISCONNECT SWITCHES (TOP) PANELBOARDS (TOP) 4' -0" 1' -6" 4' -6" 5' -6" 6' -0" 13. GROUNDING SYSTEM: THIS CONTRACTOR SHALL PROVIDE, INSTALL, AND CONNECT A COMPLETE SYSTEM OF GROUNDING FOR ALL EQUIPMENT AND STRUCTURES. MECHANICAL AND ELECTRICAL CONNECTION SHALL BE MADE WITH APPROVED GROUNDING CONNECTORS. ELECTRICAL SYSTEM AND EQUIPMENT GROUNDS SHALL COMPLY WITH ALL LOCAL, STATE, AND NEC CODES AND REGULATIONS. PANELS, CONDUIT SYSTEMS, MOTOR FRAMES, LIGHTING FIXTURES AND OTHER EQUIPMENT THAT ARE A PART OF THIS INSTALLATION SHALL BE SECURELY GROUNDED. MAIN GROUNDING SYSTEM SHALL BE SIZED TO CONFIRM WITH SECTION 250 OF THE NEC. PROVIDE CONDUIT TO PROTECT GROUND WIRE FROM DAMAGE TO AN AREA 6' -0" ABOVE FLOOR. GROUND ALL 3 WIRE RECEPTACLES TO THE OUTLET BOXES. GROUND CONDUCTOR SHALL BE SUPPLIED IN ALL NON- METALLIC CONDUIT. A SEPARATE DEDICATED, INSULATED GROUND SYSTEM SHALL BE INSTALLED FOR ELECTRONIC CASH REGISTERS. PANELBOARDS: PANELBOARDS SHALL BE DEAD FRONT AND CONSIST OF CABINETS, INTERIORS, BUS, MAIN AND BRANCH CIRCUIT PROTECTIVE DEVICES, MAIN LUGS, AND ALL NECESSARY EQUIPMENT FOR A COMPLETE PANELBOARD. DETAILED CHARACTERISTICS SUCH AS NUMBER OF BRANCHES, FRAME OR AMPERE RATING, TRIP, BUS SIZE, TYPE MOUNTING OR VOLTAGE RATINGS, SHALL BE AS SHOWN ON THE DRAWINGS. CABINET SHALL BE FABRICATED OF CODE GAUGE, HOT GALVANIZED STEEL WITH ADEQUATE GUTTERS. JOINTS SHALL BE WELDED AND REINFORCED WHERE REQUIRED. THE OUTSIDE OF SURFACE MOUNTED CABINETS SHALL BE FINISHED WITH ONE COAT OF ZINC CHROMATE PRIMER AND AT LEAST ONE COAT OF GRAY ENAMEL. LOAD CENTER TYPE PANELBOARDS ARE NOT ACCEPTABLE. TRIM AND PANELBOARD FRONT SHALL BE MADE OF COLD- ROLLED STEEL OF CODE GAUGE STEEL. TRIM SHALL HAVE DOORS WITH CONCEALED HINGES AND HAVE A FLUSH TYPE COMBINATION LOCK AND CATCH OR A MULTIPLE POINT CONTACT CATCH. EACH LOCK SHALL BE PROVIDED WITH TWO KEYS. ALL PANELBOARDS SHALL BE KEYED ALIKE. FURNISH AND INSTALL A TYPED INDEX IDENTIFYING THE PANELBOARD AND INDICATING THE CIRCUIT NUMBER WITH THE DESCRIPTION OR FUNCTION OF THE ASSOCIATED BRANCH CIRCUIT. INDEX SHALL BE MOUNTED UNDER A CLEAR GLASS OR PLASTIC PROTECTIVE COVER. TRIM SHALL BE CLEANED, AND GIVEN A PRIME COAT OF PAINT AND AT LEAST ONE FINISHED COAT OF GRAY ENAMEL. ALL LUGS SHALL BE OF THE SOLDERLESS TYPE. ALL PANELBOARDS SHALL INCLUDE EQUIPMENT GROUND BUS. ALL PANELBOARDS SHALL HAVE ENGRAVED NAMEPLATES IDENTIFYING PANELBOARDS AS INDICATED BY OWNER. ALL PANELBOARD SWITCHES AND CIRCUIT BREAKERS SHALL BE LABELED AS DIRECTED BY OWNER. PROVIDE EQUIPMENT AND ISOLATED GROUND BUSES, AS CALLED OUT IN THE PANELBOARD SCHEDULE. 277/480 VOLT PANELS SHALL BE EQUAL TO SQUARE D TYPE NF WITH TYPE EDB (25000 AIC) BOLT -ON CIRCUIT BREAKERS. 120/208 VOLT PANELS SHALL BE EQUAL TO SQUARE D TYPE NQOD WITH TYPE QOB (22000 AIC) BOLT -ON CIRCUIT BREAKERS. THE FOLLOWING ARE APPROVED MANUFACTURERS: GENERAL ELECTRIC, SIEMENS, AND SQUARE D. 14. WORK IN ELECTRICAL PANEL SHALL INCLUDE: CHECK AND TIGHTEN ALL CONNECTIONS AND WIRING. VERIFY OPERATION OF ALL BREAKERS. CIRCUIT BREAKERS SHALL BE QUICK -MAKE, QUICK- BREAK, TRIP INDICATING TYPE AMBIENT COMPENSATING. CIRCUIT BREAKERS SHALL BE BOLT ON TYPE, MINIMUM INTERRUPTING SHALL BE AS NOTED ON PANEL SCHEDULE. BREAKERS SERVING LIGHTING CIRCUITS SHALL BE RATED FOR SWITCH SERVICE. BREAKERS SERVING HVAC EQUIPMENT SHALL BE HACR RATED. PROVIDE "LOCK -ON" DEVICE AT BREAKERS SERVING CASH REGISTER, NIGHT LIGHT /EMERGENCY, FIRE ALARM EQUIPMENT AND TIME SWITCH CIRCUITS, AS THE PANEL SCHEDULE. PROVIDE PANEL DIRECTORY, TYPED AND INSTALLED BEHIND CLEAR PLASTIC COVER ON INSIDE OF THE DOOR. PANEL SHALL BE CIRCUITED SO THAT THE LOAD IS DISTRIBUTED EVENLY ACROSS ALL THREE PHASES TO WITHIN 10% PER NEC. 15. SAFETY AND DISCONNECT SWITCHES: PROVIDE SAFETY AND DISCONNECT SWITCHES, FUSED OR NON- FUSED, AS CALLED FOR ON DRAWING AND AS REQUIRED BY CODE. SWITCHES SHALL BE HEAVY DUTY, LOAD AND HORSEPOWER RATED. EQUAL TO SQUARE 16. D TYPE H, AS MANUFACTURED BY SQUARE D, GENERAL ELECTRIC OR EQUAL. SWITCH ENCLOSURE TO BE SUITABLE FOR APPLICATION. AND INDICATED ON 17. FUSES: CARTRIDGE FUSES SHALL BE ONE TIME BUSSMANN "LOW- PEAK" SIZED ACCORDING TO THE LOAD OR AS INDICATED ON THE DRAWINGS. PROVIDE FUSES IN ALL SWITCHES REQUIRING THEM. IN ADDITION, FURNISH TO THE OWNER ONE SET OF EACH SIZE AND TYPE FUSE ON THE JOB. 18. DRY TYPE TRANSFORMERS: TRANSFORMERS SHALL BE OF KVA RATING AS NOTED ON THE DRAWINGS, 2 WINDING, DRY TYPE, 3 PHASE, WITH SIX 2 -1/2% TAPS, 2 ABOVE AND 4 BELOW NORMAL PRIMARY VOLTAGE. TRANSFORMER SHALL BE NEMA TYPE 1, QUIET TYPE WITH CORE AND COILS ISOLATED FROM THE CASE BY VIBRATION DAMPERS. TRANSFORMERS SHALL BE EQUAL TO SQUARE D TYPE WATCHDOG (TP -1), AS MANUFACTURED BY SQUARE -D, GENERAL ELECTRIC, OR EQUAL. 19. SEISMIC RESTRAINS ON ELECTRICAL EQUIPMENT: ALL ELECTRICAL EQUIPMENT SHALL BE PROVIDED WITH SEISMIC RESTRAINING SERVICES AS REQUIRED BY LOCAL BUILDING CODES. CONTRACTOR SHALL HAVE LOCAL BUILDING OFFICE REVIEW EACH PIECE OF EQUIPMENT WHEN INSTALLED AND THE CONTRACTOR SHALL INSTALL ALL REQUIRED TIE DOWN, ANCHORS, STRAPS OR OTHER DEVICES REQUIRED. 20. TELEPHONE SYSTEM: MAKE ARRANGEMENTS WITH THE LOCAL UTILITY FOR INSTALLATION OF TELEPHONE SERVICE. CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION WITHIN TENANTS PREMISES SHALL BE PROVIDED AS REQUIRED BY CODE OR AS INDICATED ON THE DRAWINGS. TELEPHONE ROUGH -IN OUTLET BOXES SHALL BE 2 -1/8" MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. 21. THIS CONTRACTOR SHALL MAKE ARRANGEMENTS FOR TEMPORARY POWER AND SHALL PAY COST FOR THE UTILITY CONNECTION AND SHALL BE RESPONSIBLE FOR THE PROPER MAINTENANCE OF THE TEMPORARY WORK AND FOR THE REMOVAL OF SAME. CONTRACTOR SHALL PAY ALL UTILITY CHARGES IN CONNECTION WITH THE TEMPORARY POWER. CONTRACTOR SHALL PROVIDE GROUND FAULT PROTECTION FOR ALL EQUIPMENT USED ON THE PREMISES DURING CONSTRUCTION. 22. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING, OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK HEREIN SPECIFIED. ANY CUTTING SHALL HAVE PRIOR APPROVAL BY THE LANDLORD. CONTRACTOR IS RESPONSIBLE TO TAKE WHATEVER MEASURES ARE NECESSARY INCLUDING BUT NOT LIMITED TO THOSE MEASURES PRESCRIBED BY THE LANDLORD IN THE EXERCISE OF ITS REASONABLE JUDGEMENT TO ASSURE THAT COREBORING WILL NOT DAMAGE LANDLORD'S STRUCTURE, CONDUITS, ETC. OR THE WORK OF OTHER TENANT'S BELOW. THE COST OF SUCH TESTS OR REPAIR OF ANY DAMAGE WILL BE BORNE BY THIS CONTRACTOR. ALL SLEEVED, OPENINGS, ETC. THROUGH FIRE RATED WALLS AND FLOORS SHALL BE SEALED AFTER CONDUIT INSTALLATION WITH SEALER EQUAL TO OR EXCEEDING FIRE RATING OF FLOOR OR WALL. THE 23. ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIR. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL, SUCH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE SECURED TO THE BUILDING STRUCTURE, NOT TO PIPING OR DUCTWORK. ALL CONDUIT SHALL BE CONCEALED WHERE POSSIBLE. EXPOSED CONDUIT SHALL BE RUN IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES AND SEPARATED AT LEAST 3" FROM WATER LINES WHEREVER THEY RUN ALONG SIDE OR ACROSS SUCK LINES. 24. LIGHTING FIXTURES: THE CONTRACTOR SHALL INSTALL A NEW LIGHTING FIXTURE OF THE TYPE SPECIFIED FOR EACH LIGHTING OUTLET SHOWN WITH COMPLETE LAMPS OR TUBES. ALL FIXTURES SHALL BE HUNG AND MOUNTED IN PLACE, PROPERLY WIRED, TESTED AND LEFT READY FOR OPERATION. NOTE! THIS CONTRACTOR SHALL REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, FOR FIXTURE SCHEDULE AND SHALL INSTALL FIXTURES AS DIMENSIONED ON THAT PLAN. THE OWNER SELECTS AND PROVIDES ALL LIGHTING FIXTURES, COMPLETE WITH ACCESSORIES AND LAMPS. REFER TO THE LIGHT FIXTURE SCHEDULE ON ELECTRICAL DRAWINGS. FIXTURES PROVIDED BY OWNER SHALL BE SHIPPED TO THE SITE FOR INSTALLATION BY THE ELECTRICAL CONTRACTOR, THE CONTRACTOR SHALL SURVEY THE SHIPMENT TO VERIFY FIXTURE QUANTITIES AND DAMAGES. IN THE EVENT THAT SHIPMENT IS INCOMPLETE OR DAMAGED, THIS CONTRACTOR SHALL INFORM OWNER. AFTER THE SHIPMENT IS VERIFIED AND ACCEPTED, CONTRACTOR SHALL MOVE FIXTURE TO AN AREA OF SAFETY FOR STORAGE UNTIL THEY MAY BE INSTALLED. HE ASSUMES RESPONSIBILITY FOR THE FIXTURES UNTIL THE PROJECT IS TURNED OVER TO THE OWNER. 25. PAINTING OF ELECTRICAL CONDUITS, ETC., IF REQUIRED, WILL BE BY GENERAL CONTRACTOR. 26. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN HIS WORK AS THE JOB PROGRESSES, AND UPON COMPLETION SHALL TURN OVER TO THE TENANT A RECORD SET OF PRINTS SHOWING THESE CHANGES. 27. AT THE COMPLETION OF JOB, CONTRACTOR SHALL REPLACE ANY LAMPS THAT HAVE BURNED OUT, NEW AND EXISTING, CLEAN ALL FIXTURES, TOUCH UP ANY SCRATCHES AND REPLACE ANY FIXTURES THAT HAVE BEEN DAMAGED. 28. GUARANTEE: MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THIS CONTRACTOR'S EXPENSE. FOR THE SAME PERIOD, ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND /OR INSTALLED BY HIM. WARRANTY OF ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF PROJECT CLOSE -OUT. 29. IT IS THE INTENT THAT THE FOREGOING WORT( SHALL BE COMPLETE IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. 30. THE LOCATION OF RECEPTACLES AND FIXTURES SHOWN ON THE DRAWING IS APPROXIMATE AND THE OWNER SHALL HAVE THE RIGHT TO RELOCATE ANY RECEPTACLES OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. SYMBOL O SINGLE POLE WALL SWITCH 2 $ WALL SWITCH - DESIGNATIONS AS FOLLOWS: 2 =2 POLE 4 =4 -WAY 3 =3 -WAY P =PILOT LIGHT M =MOTOR RATED S\M rCH H= LIGHTED HANDLE DM= DIMMER MS= MOTION SENSOR SWITCH (HUBBELL #ATP1277W) GF 6 18 Fl LV +12" OD DESCRIPTION EXHAUST FAN DATA OUTLET TELEPHONE OUTLET TIMESWITCH SCALE: N/A CONDUIT UP +2" UNLESS NOTED CONDUIT DOWN CONDUIT HOMERUN UNDERGROUND CONDUIT HOMERUN CONDUIT - AS SHOWN INDICATES (1) HOT /SWITCH LEG, (1) NEUTRAL, (1) GROUND UNDERGROUND CONDUIT - AS SHOWN INDICATES (1) HOT /SWITCH LEG, (1) NEUTRAL, (1) GROUND THREE PHASE CIRCUIT - TICK MARK INDICATES (3) CONDUCTORS, (1) GROUND SINGLE PHASE CIRCUIT - TICK MARK INDICATES (2) CONDUCTORS, (1) GROUND * NOTE: 3 -WAY AND 4 -WAY SWITCHING REQUIRES ADDITIONAL CONDUCTORS FOR PROPER OPERATION. PROVIDE AS REQUIRED FOR A COMPLETE WORKING LIGHTING CONTROL SYSTEM. PROVIDE UN- SWITCHED HOT TO ALL EMERGENCY LIGHTING FIXTURES AND EXIT SIGNS. SIMPLEX RECEPTACLE - NEMA 5 -20R UNLESS NOTED OTHERWISE DUPLEX RECEPTACLE - NEMA 5 -20R UNLESS NOTED OTHERWISE DOUBLE- DUPLEX RECEPTACLE - NEMA 5 -20R UNLESS NOTED OTHERWISE RECEPTACLE DESIGNATIONS AS FOLLOWS: GFCI = GROUND FAULT INTERRUPTER WP= WEATHERPROOF S= SWITCHED - E= EMERGENCY POWER IG= ISOLATED GROUND AC =ABOVE COUNTER HEAVY DUTY RECEPTACLE - NEMA TYPE AS NOTED ON PLANS. FLOOR MOUNTED DUPLEX RECEPTACLE CEILING MOUNTED DUPLEX RECEPTACLE QUAD RECEPTACLE JUNCTION BOX LOW VOLTAGE BELL LOW VOLTAGE CHIME SUB - WOOFER SPEAKERS ELECTRICAL SYMBOLS NON -FUSED DISCONNECT SWITCH 60/3 = 60 AMP SWITCH, 3 POLE FUSED DISCONNECT SWITCH 60/3/40 = 60 AMP SWITCH, 3 POLE, 40 AMP FUSE LOW VOLTAGE 12" ABOVE FLOOR LINE OF AREA WHERE SHOWN ELECTRICAL PANELBOARD DUCT SMOKE DETECTOR 1 2 3 4 7 9 10 11 12 LCK,IG LANDLORD'S MAIN DISTRIBUTION AND MASTER METERING EQUIPMENT LOCATED IN LANDLORD'S ELECTRICAL ROOM. VERIFY LOCATION ON SITE. LANDLORD SHALL PROVIDE (4) #3/0 AND (1) #6 GROUND IN 2" CONDUIT FROM LANDLORD'S DISTRIBUTION EQUIPMENT TO TENANT SPACE. F LC1 LC1 LC1 LC2 LC2 LC2 LC2 LC3 LC LC2 17 LANDLORD PROVIDED MAIN CIRCUIT BREAKER. UTILITY METER WITHIN LANDLORD'S EQUIPMENT. COORDINATE ALL REQUIREMENTS WITH LANDLORD AND UTILITY COMPANY. CONTRACTOR SHALL EXTEND FEEDERS AND CONDUIT, AS REQUIRED, TO PANELBOARD 'HP' WITHIN TENANT SPACE. PROVIDE 225 AMP PANELBOARD 'HP' WITH 125 AMP MAIN CIRCUIT BREAKER. SEE PANELBOARD SCHEDULES FOR MORE INFORMATION. PROVIDE (3) #6 FEEDERS IN 1" CONDUIT FROM PANELBOARD 'HP' TO TRANSFORMER 'T1'. PROVIDE 45 KVA DRY TYPE TRANSFORMER WITH 480V, 3 PHASE DELTA PRIMARY TO 120/208V, 3 PHASE WYE SECONDARY. TRANSFORMER SHALL BE FLOOR MOUNTED. PROVIDE #6 GROUND IN CONDUIT FROM TRANSFORMER TO BUILDING STEEL. PROVIDE (4) #1/0, (1) #6 GROUND, AND (1) #6 ISOLATED GROUND IN 2" CONDUIT FROM TRANSFORMER 'T1' TO PANELBOARD 'PP'. PROVIDE 225 AMP PANELBOARD 'PP' WITH 150 AMP MAIN CIRCUIT BREAKER. SEE PANELBOARD SCHEDULES FOR MORE INFORMATION. PROVIDE 225 AMP PANELBOARD 'LP' WITH MAIN LUGS ONLY. SEE PANELBOARD SCHEDULES FOR MORE INFORMATION. POWER RISER DIAGRAM SCALE: N/A 13 14 FURNISH AND INSTALL TORK DZS400A (7 -DAY PROGRAMMABLE) TIME CLOCK TO CONTROL LIGHTING CONTACTORS. SET TIME AS DIRECTED BY LANDLORD AND OWNER. FURNISH AND INSTALL (3) ACO 917 LIGHTING CONTACTORS, POLES AS REQUIRED, IN STANDARD NEMA 1 ENCLOSURE. MOUNT ADJACENT TO PANEL LP. 4 HP 6 8 PP 10 LP 12 fl NOTE: THIS RISER DIAGRAM REPRESENTS (AS ACCURATELY AS POSSIBLE) THE EXISTING ELECTRICAL DISTRIBUTION SYSTEM. FIELD VERIFY ALL SIZES OF EQUIPMENT, CONDUCTORS, FUSES, ETC. SIZES SHOWN ON THIS DRAWING SHALL BE CONSIDERED A MINIMUM. ANY EXISTING EQUIPMENT CONDUCTORS, FUSES, ETC. WHICH DO NOT MEET MINIMUM SHALL BE REPLACED TO MEET MINIMUM. FUSES FOR HVAC EQUIPMENT SHALL BE PER UNIT NAMEPLATE DATA FUSE AMPACITY SHALL NOT EXCEED CONDUCTOR AMPACITY. 13 14 PANELBOARD SCHEDULES SCALE: N/A G,LCK G,LCK G,LCK EM E M,LC3 LC2 LC2 LC2 LC2 EM,LC3 LC2 LC2 LC2 LC2 LC2 ELO 0 ° v 4 0 vv M M W -1 a`� I j u_ 1-- PROJECT TEAM: Architect: Epoch Design Group, Inc. 1 155 Olivette Exec. Pkwy. Suite 100 St. Louis, MO 63132 TEL: 314.721.1340 FAX: 314.721.0344 M. E. P. & F.P. Engineer: COPYRIGHT DISCLAIMER: RANDALL A. NELSON 8016 Reeder Rd. Lenexa, KS 66214 TEL, 913- 322 -5150 FAX, 913- 322 -5155 THIS DOCUMENT IS THE PROPERTY OF EPOCH DESIGN GROUP, COPYRIGHTED M DATED, ALL RIGHTS RESERVED. AUTHORIZATION FROM EPOCH DESIGN GROUP FOR USE OF THIS DOCUMENT IS NOT TRANSFERABLE. THE RECIPIENT OF THIS DOCUMENT I5 HEREBY ADVISED THAT IT IS RELEASED FOR USE UNDER THE FOLLOWING TERMS AND CONDITIONS. THE DOCUMENT IS TO BE USED ONLY IN CONJUNCTION WITH TIES PROJECT. REUSE OF ANY PORTION OF THE DOCUMENT IN ANY OTHER CIRCUMSTANCE CONSTITUTES COPYRIGHT INFRINGEMENT. THE DOCUMENT IS FOR DESIGN INTENT AND INFORMATION ONLY, AND DOES tigi CONSTITUTE AS -BUILT CONDITIONS. THE RECIPIENT RETAINS THE OBLIGATION TO VERIFY THE CONDITIONS OF THE SUBJECT PROPERTY MID TO COMPLETELY COORDINATE ALL DIMENSIONS, FABRICATION METHODS, RELATED AND INTEGRATED SYSTEMS, ETC, WITH RESPECT TO ALL ASPECTS OF THE WORK. EPOCH DESIGN GROUP MAKES NO WARRANTY AS TO THE SUITABILITY OF THE DOCUMENT FOR THE RECIPIENTS INTENDED USE. THE RECIPIENT SPECIFICALLY AGREES TO WAIVE AND TO INDEMNIFY AND DEFEND ANY AND ALL CLAIMS AGAINST EPOCH DESIGN GROUP, ITS CONSULTANTS, ANY OF ITS RELATED ENTITIES, VENDORS, OR CON R C OR3 FOIL MIY LOSS INCURRED A S RESULT OF PR P 4 IACRROPERy'1}SF,IP THIS DOCUMENT. THE RECIPIE GREF T LA1 pR DE,£JI:j �OYHIi DOCUMENT UPON C ETIQ.L7 k LAN 6Pa WO ORMED 5911 ION THIS PROJECT. PROJECT TITLE: SHEET TITLE: PROJECT NO.: 07073 DRAWN BY: LBS ISSUE DATE: 11/07/07 0 uJ t O Z ,- `n w Uj O = iO Z h- ~ Z cv• w v)ON 111 tn -"( a. O RECEIVED CITY OF TIJKVUILA DEC 1 1 2007 P�HIVl1T CEN I ER W (I) No.41 Revision Description Date ELECTRICAL SPECIFICATIONS, PANELS, AND RISER SHEET NUMBER: E4.0 20 A B C NEUTRAL GROUND BLACK RED BLUE WHITE GREEN NOTE: MANUFACTURERS' NAMES ON WHICH THE SPECIFICATION IS BASED INDICATE THE MINIMUM QUALITY OF PRODUCT REQUIRED. SUBSTITUTION MAY BE MADE TO THOSE SPECIFIED IF DEEMED EQUIVALENT BY THE OWNER'S REPRESENTATIVE. ALL WORK AND PRODUCTS SHALL MEET THE REQUIREMENTS OF THE LANDLORD. 1. THE GENERAL CONDITIONS AND SUPPLEMENTARY GENERAL CONDITIONS SHALL BE CONSIDERED AS PART OF THIS SPECIFICATION. 2. CONTRACTORS SHALL VISIT SITE PRIOR TO BIDDING. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS. FIELD VERIFY LANDLORD'S ELECTRICAL AND TELEPHONE EQUIPMENT AND DISTANCE FROM LEASED SPACE. NO CLAIMS FOR EXTRAS RESULTING FROM LACK OF KNOWLEDGE OF EXISTING SITE CONDITIONS SHALL BE APPROVED. 3. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. ALL MATERIALS AND EQUIPMENT SHALL BE COMMERCIAL GRADE AND SHALL CARRY A U.L. LABEL. MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING COMPONENTS THEREOF SHALL BE NEW AND SUCH AS APPEARS ON THE UNDERWRITER'S LABORATORY LIST OF APPROVED ITEMS AND SHALL MEET THE REQUIREMENTS OF RECOGNIZED STANDARDS. EQUIPMENT SHALL BE SIZED IN CONFORMITY WITH REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AND OTHER APPLICABLE CODES. 4. THE WORD "PROVIDE" AS USED HEREIN MEANS TO FURNISH AND INSTALL COMPLETE. 5. ALL WORK TO BE IN ACCORDANCE WITH NEC AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES. 6. CONTRACTOR SHALL BE RESPONSIBLE TO COMPLETE ALL FORMS REQUIRED TO SECURE AND PAY FOR ALL REQUIRED PERMITS AND INSPECTION CERTIFICATES. 7. SUBMIT MATERIAL LISTS AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE ARCHITECT FOR APPROVAL. SUBMITTALS SHALL BE IN ACCORDANCE WITH GENERAL CONDITIONS AND SHALL BEAR THE STAMP OF THE ELECTRICAL CONTRACTOR SHOWING THAT HE HAS REVIEWED AND APPROVED THEM. LACK OF SUCH CONTRACTOR'S APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY THE ARCHITECT. 8. SCOPE OF WORK: PROVIDE ELECTRICAL SERVICE TO SPACE PER DRAWINGS AND LANDLORDS REQUIREMENTS. INSTALL NEW LIGHTING FIXTURES, PER SCHEDULE. NEW RECEPTACLES AS INDICATED. IF APPLICABLE, CIRCUITING OF RELOCATED PANEL(S). PROVIDE NEW CIRCUIT BREAKERS AS REQUIRED. RELOCATE TRANSFORMER. PROVIDE TELEPHONE SERVICE AND TELEPHONE SYSTEM RACEWAY AND JUNCTION BOXES. ALL TELEPHONE SYSTEM WIRING AND DEVICES WITHIN TENANT SPACE FURNISHED AND INSTALLED BY OWNER. TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION. TESTING OF ALL ELECTRICAL EQUIPMENT. PROVISION FOR TEMPORARY CONSTRUCTION POWER. 9. CONDUIT SHALL BE STANDARD STEEL, RIGID IMC OR EMT (THIN WALL). CONDUIT SHALL BE CONCEALED IN FINISHED AREAS. EXCEPT AS OTHERWISE APPROVED BY LANDLORD'S REPRESENTATIVE. EMT CONNECTIONS SHALL BE COMPRESSION TYPE. MINIMUM SIZES OF CONDUIT SHALL BE 3/4" EXCEPT 1/2" FOR SWITCH LEGS. EMT SHALL BE GALVANIZED OR ELECTRO- GALVANIZED. EMT SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS RUN ABOVE SUSPENDED CEILINGS OR CONCEALED IN INTERIOR PARTITIONS. EMT SHALL NOT BE CONCEALED IN POURED CONCRETE FLOOR OR WALLS. USE HEAVY WALL CONDUIT OR IMC FOR UNDER SLAB INSTALLATIONS. IMC IS PERMITTED WITH SCREW CONNECTIONS. FLEXIBLE METAL CONDUIT MAY BE USED ONLY FOR SHORT CONNECTIONS TO FIXTURES AND EQUIPMENT, AS PERMITTED BY CODE. MAXIMUM LENGTH 5' -0 ". 10. ALL CONDUCTORS SHALL BE SOFT DRAWN, ANNEALED COPPER, WITH 600V INSULATION: #10 AND SMALLER -SOLID WITH SINGLE BRAID. #8 AND LARGER- STRANDED WITH AT LEAST DOUBLE BRAID. ALL WIRING TO BE 2 #12, UNLESS OTHERWISE NOTED. #14 MAY BE USED FOR CONTROL APPLICATIONS. ALL LOW VOLTAGE WIRING NOT REQUIRED TO BE IN CONDUIT SHALL BE FIRE RETARDANT PLENUM RATED. ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. GENERAL WIRING SHALL HAVE (75' C) THW AND THWN OR (90' C) THHN INSULATION. ALUMINUM CONDUCTORS ARE NOT PERMITTED. WIRE CONNECTORS SHALL BE EQUAL TO SCOTCHLOCK FOR #8 AND SMALLER, AND T &B "LOCK -TITE" FOR #6 AND LARGER. WIRES SHALL BE COLOR CODED AND FOLLOWED THROUGHOUT FOR FEEDERS AND BRANCH CIRCUITS AND USED AS A BASIS FOR BALANCING LOADS: USE 10 AWG (MINIMUM) CONDUCTORS FOR 20 AMPERE, 120 VOLT BRANCH CIRCUITS LONGER THAN 75 FEET. USE 10 AWG (MINIMUM) CONDUCTORS FOR THAN 150 FEET. 120/208 Y VOLTS PHASE COLOR 20 AMPERE, 277 VOLT BRANCH CIRCUITS LONGER 277/480 Y VOLTS PHASE COLOR A YELLOW B BROWN C ORANGE NEUTRAL WHITE W /TRACER OR GRAY GROUND GREEN 11. BOXES AND FITTINGS: BOXES AND FITTINGS SHALL BE NEW, TOP QUALITY AND LOCATED WHERE REQUIRED TO INSTALL THE CONDUCTORS IN COMPLIANCE WITH THE PREVAILING CODES. APPROVED MANUFACTURES ARE: STEEL CITY, RACO OR APPLETON. SHEET METAL BOXES: NEMA OS 1. CAST METAL BOXES: NEMA FB 1, TYPE FS OR FD, CAST FERROALLOY BOX WITH GASKETED COVER. BOXES IN FIRE -RATED WALLS SHALL HAVE A FIRE RATING EQUAL TO OR GREATER THAN THE RATING OF THE WALL. 12. WIRING DEVICES: WALL SWITCHES, SINGLE POLE, DOUBLE POLE, AND THREE WAY SHALL BE SPEC. GRADE, 20A, 120/277V, WITH SCREW TERMINALS, EQUAL TO HUBBELL #HBL1221. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR OR LEVITON. GENERAL DUTY DUPLEX RECEPTACLES SHALL BE 2 -POLE, 3 -WIRE GROUNDING TYPE, COMMERCIAL GRADE, 20A, 125V EQUAL TO HUBBELL #5362. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR, OR LEVITON. GROUND FAULT INTERRUPTER RECEPTACLE SHALL BE, DUPLEX RECEPTACLES, FEED - THROUGH TYPE, CAPABLE OF PROTECTING CONNECTED DOWNSTREAM RECEPTACLES ON A SINGLE CIRCUIT, 20A, 120V, 60 HZ; WITH SOLID -STATE GROUND FAULT SENSING AND SIGNALING; WITH 5 MILLIAMPERES GROUND -FAULT TRIP LEVEL EQUAL TO HUBBELL #GF5362. APPROVED MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR, OR LEVITON. WEATHERPROOF RECEPTACLE COVER SHALL BE HUBBELL #WP826MP. APPROVED MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR, OR LEVITON. DEDICATED DUPLEX RECEPTACLES SHALL BE RED, 2 -POLE, 3 -WIRE 20A, 125V, STRAIGHT BLADE DEVICE WITH DEDICATED GROUND CONNECTION, EQUAL TO HUBBELL #5362 -R. APPROVED MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR, OR LEVITON. WIRING DEVICE ACCESSORIES INCLUDING ALL WALL PLATES SHALL BE PROVIDED AT EACH DEVICE. WALL PLATES SHALL BE SAME COLOR AS DEVICE AND MANUFACTURED AS A ICAL SPECIFICATIONS COMPANION TO THE DEVICE. ALL WIRING DEVICES AND COVERPLATES SHALL BE WHITE UNLESS NOTED OTHERWISE. MOUNTING HEIGHTS OF DEVICES SHALL BE TO THE FOLLOWING CENTERLINES, UNLESS NOTED OTHERWISE: TOGGLE SWITCHES RECEPTACLES TELEPHONE OUTLETS DISCONNECT SWITCHES (TOP) PANELBOARDS (TOP) 4' -0" 1' -6" 4' -6" 5' -6" 6' -0" 13. GROUNDING SYSTEM: THIS CONTRACTOR SHALL PROVIDE, INSTALL, AND CONNECT A COMPLETE SYSTEM OF GROUNDING FOR ALL EQUIPMENT AND STRUCTURES. MECHANICAL AND ELECTRICAL CONNECTION SHALL BE MADE WITH APPROVED GROUNDING CONNECTORS. ELECTRICAL SYSTEM AND EQUIPMENT GROUNDS SHALL COMPLY WITH ALL LOCAL, STATE, AND NEC CODES AND REGULATIONS. PANELS, CONDUIT SYSTEMS, MOTOR FRAMES, LIGHTING FIXTURES AND OTHER EQUIPMENT THAT ARE A PART OF THIS INSTALLATION SHALL BE SECURELY GROUNDED. MAIN GROUNDING SYSTEM SHALL BE SIZED TO CONFIRM WITH SECTION 250 OF THE NEC. PROVIDE CONDUIT TO PROTECT GROUND WIRE FROM DAMAGE TO AN AREA 6' -0" ABOVE FLOOR. GROUND ALL 3 WIRE RECEPTACLES TO THE OUTLET BOXES. GROUND CONDUCTOR SHALL BE SUPPLIED IN ALL NON- METALLIC CONDUIT. A SEPARATE DEDICATED, INSULATED GROUND SYSTEM SHALL BE INSTALLED FOR ELECTRONIC CASH REGISTERS. PANELBOARDS: PANELBOARDS SHALL BE DEAD FRONT AND CONSIST OF CABINETS, INTERIORS, BUS, MAIN AND BRANCH CIRCUIT PROTECTIVE DEVICES, MAIN LUGS, AND ALL NECESSARY EQUIPMENT FOR A COMPLETE PANELBOARD. DETAILED CHARACTERISTICS SUCH AS NUMBER OF BRANCHES, FRAME OR AMPERE RATING, TRIP, BUS SIZE, TYPE MOUNTING OR VOLTAGE RATINGS, SHALL BE AS SHOWN ON THE DRAWINGS. CABINET SHALL BE FABRICATED OF CODE GAUGE, HOT GALVANIZED STEEL WITH ADEQUATE GUTTERS. JOINTS SHALL BE WELDED AND REINFORCED WHERE REQUIRED. THE OUTSIDE OF SURFACE MOUNTED CABINETS SHALL BE FINISHED WITH ONE COAT OF ZINC CHROMATE PRIMER AND AT LEAST ONE COAT OF GRAY ENAMEL. LOAD CENTER TYPE PANELBOARDS ARE NOT ACCEPTABLE. TRIM AND PANELBOARD FRONT SHALL BE MADE OF COLD- ROLLED STEEL OF CODE GAUGE STEEL. TRIM SHALL HAVE DOORS WITH CONCEALED HINGES AND HAVE A FLUSH TYPE COMBINATION LOCK AND CATCH OR A MULTIPLE POINT CONTACT CATCH. EACH LOCK SHALL BE PROVIDED WITH TWO KEYS. ALL PANELBOARDS SHALL BE KEYED ALIKE. FURNISH AND INSTALL A TYPED INDEX IDENTIFYING THE PANELBOARD AND INDICATING THE CIRCUIT NUMBER WITH THE DESCRIPTION OR FUNCTION OF THE ASSOCIATED BRANCH CIRCUIT. INDEX SHALL BE MOUNTED UNDER A CLEAR GLASS OR PLASTIC PROTECTIVE COVER. TRIM SHALL BE CLEANED, AND GIVEN A PRIME COAT OF PAINT AND AT LEAST ONE FINISHED COAT OF GRAY ENAMEL. ALL LUGS SHALL BE OF THE SOLDERLESS TYPE. ALL PANELBOARDS SHALL INCLUDE EQUIPMENT GROUND BUS. ALL PANELBOARDS SHALL HAVE ENGRAVED NAMEPLATES IDENTIFYING PANELBOARDS AS INDICATED BY OWNER. ALL PANELBOARD SWITCHES AND CIRCUIT BREAKERS SHALL BE LABELED AS DIRECTED BY OWNER. PROVIDE EQUIPMENT AND ISOLATED GROUND BUSES, AS CALLED OUT IN THE PANELBOARD SCHEDULE. 277/480 VOLT PANELS SHALL BE EQUAL TO SQUARE D TYPE NF WITH TYPE EDB (25000 AIC) BOLT -ON CIRCUIT BREAKERS. 120/208 VOLT PANELS SHALL BE EQUAL TO SQUARE D TYPE NQOD WITH TYPE QOB (22000 AIC) BOLT -ON CIRCUIT BREAKERS. THE FOLLOWING ARE APPROVED MANUFACTURERS: GENERAL ELECTRIC, SIEMENS, AND SQUARE D. 14. WORK IN ELECTRICAL PANEL SHALL INCLUDE: CHECK AND TIGHTEN ALL CONNECTIONS AND WIRING. VERIFY OPERATION OF ALL BREAKERS. CIRCUIT BREAKERS SHALL BE QUICK -MAKE, QUICK- BREAK, TRIP INDICATING TYPE AMBIENT COMPENSATING. CIRCUIT BREAKERS SHALL BE BOLT ON TYPE, MINIMUM INTERRUPTING SHALL BE AS NOTED ON PANEL SCHEDULE. BREAKERS SERVING LIGHTING CIRCUITS SHALL BE RATED FOR SWITCH SERVICE. BREAKERS SERVING HVAC EQUIPMENT SHALL BE HACR RATED. PROVIDE "LOCK -ON" DEVICE AT BREAKERS SERVING CASH REGISTER, NIGHT LIGHT /EMERGENCY, FIRE ALARM EQUIPMENT AND TIME SWITCH CIRCUITS, AS THE PANEL SCHEDULE. PROVIDE PANEL DIRECTORY, TYPED AND INSTALLED BEHIND CLEAR PLASTIC COVER ON INSIDE OF THE DOOR. PANEL SHALL BE CIRCUITED SO THAT THE LOAD IS DISTRIBUTED EVENLY ACROSS ALL THREE PHASES TO WITHIN 10% PER NEC. 15. SAFETY AND DISCONNECT SWITCHES: PROVIDE SAFETY AND DISCONNECT SWITCHES, FUSED OR NON- FUSED, AS CALLED FOR ON DRAWING AND AS REQUIRED BY CODE. SWITCHES SHALL BE HEAVY DUTY, LOAD AND HORSEPOWER RATED. EQUAL TO SQUARE 16. D TYPE H, AS MANUFACTURED BY SQUARE D, GENERAL ELECTRIC OR EQUAL. SWITCH ENCLOSURE TO BE SUITABLE FOR APPLICATION. AND INDICATED ON 17. FUSES: CARTRIDGE FUSES SHALL BE ONE TIME BUSSMANN "LOW- PEAK" SIZED ACCORDING TO THE LOAD OR AS INDICATED ON THE DRAWINGS. PROVIDE FUSES IN ALL SWITCHES REQUIRING THEM. IN ADDITION, FURNISH TO THE OWNER ONE SET OF EACH SIZE AND TYPE FUSE ON THE JOB. 18. DRY TYPE TRANSFORMERS: TRANSFORMERS SHALL BE OF KVA RATING AS NOTED ON THE DRAWINGS, 2 WINDING, DRY TYPE, 3 PHASE, WITH SIX 2 -1/2% TAPS, 2 ABOVE AND 4 BELOW NORMAL PRIMARY VOLTAGE. TRANSFORMER SHALL BE NEMA TYPE 1, QUIET TYPE WITH CORE AND COILS ISOLATED FROM THE CASE BY VIBRATION DAMPERS. TRANSFORMERS SHALL BE EQUAL TO SQUARE D TYPE WATCHDOG (TP -1), AS MANUFACTURED BY SQUARE -D, GENERAL ELECTRIC, OR EQUAL. 19. SEISMIC RESTRAINS ON ELECTRICAL EQUIPMENT: ALL ELECTRICAL EQUIPMENT SHALL BE PROVIDED WITH SEISMIC RESTRAINING SERVICES AS REQUIRED BY LOCAL BUILDING CODES. CONTRACTOR SHALL HAVE LOCAL BUILDING OFFICE REVIEW EACH PIECE OF EQUIPMENT WHEN INSTALLED AND THE CONTRACTOR SHALL INSTALL ALL REQUIRED TIE DOWN, ANCHORS, STRAPS OR OTHER DEVICES REQUIRED. 20. TELEPHONE SYSTEM: MAKE ARRANGEMENTS WITH THE LOCAL UTILITY FOR INSTALLATION OF TELEPHONE SERVICE. CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION WITHIN TENANTS PREMISES SHALL BE PROVIDED AS REQUIRED BY CODE OR AS INDICATED ON THE DRAWINGS. TELEPHONE ROUGH -IN OUTLET BOXES SHALL BE 2 -1/8" MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. 21. THIS CONTRACTOR SHALL MAKE ARRANGEMENTS FOR TEMPORARY POWER AND SHALL PAY COST FOR THE UTILITY CONNECTION AND SHALL BE RESPONSIBLE FOR THE PROPER MAINTENANCE OF THE TEMPORARY WORK AND FOR THE REMOVAL OF SAME. CONTRACTOR SHALL PAY ALL UTILITY CHARGES IN CONNECTION WITH THE TEMPORARY POWER. CONTRACTOR SHALL PROVIDE GROUND FAULT PROTECTION FOR ALL EQUIPMENT USED ON THE PREMISES DURING CONSTRUCTION. 22. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING, OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK HEREIN SPECIFIED. ANY CUTTING SHALL HAVE PRIOR APPROVAL BY THE LANDLORD. CONTRACTOR IS RESPONSIBLE TO TAKE WHATEVER MEASURES ARE NECESSARY INCLUDING BUT NOT LIMITED TO THOSE MEASURES PRESCRIBED BY THE LANDLORD IN THE EXERCISE OF ITS REASONABLE JUDGEMENT TO ASSURE THAT COREBORING WILL NOT DAMAGE LANDLORD'S STRUCTURE, CONDUITS, ETC. OR THE WORK OF OTHER TENANT'S BELOW. THE COST OF SUCH TESTS OR REPAIR OF ANY DAMAGE WILL BE BORNE BY THIS CONTRACTOR. ALL SLEEVED, OPENINGS, ETC. THROUGH FIRE RATED WALLS AND FLOORS SHALL BE SEALED AFTER CONDUIT INSTALLATION WITH SEALER EQUAL TO OR EXCEEDING FIRE RATING OF FLOOR OR WALL. THE 23. ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIR. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL, SUCH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE SECURED TO THE BUILDING STRUCTURE, NOT TO PIPING OR DUCTWORK. ALL CONDUIT SHALL BE CONCEALED WHERE POSSIBLE. EXPOSED CONDUIT SHALL BE RUN IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES AND SEPARATED AT LEAST 3" FROM WATER LINES WHEREVER THEY RUN ALONG SIDE OR ACROSS SUCK LINES. 24. LIGHTING FIXTURES: THE CONTRACTOR SHALL INSTALL A NEW LIGHTING FIXTURE OF THE TYPE SPECIFIED FOR EACH LIGHTING OUTLET SHOWN WITH COMPLETE LAMPS OR TUBES. ALL FIXTURES SHALL BE HUNG AND MOUNTED IN PLACE, PROPERLY WIRED, TESTED AND LEFT READY FOR OPERATION. NOTE! THIS CONTRACTOR SHALL REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, FOR FIXTURE SCHEDULE AND SHALL INSTALL FIXTURES AS DIMENSIONED ON THAT PLAN. THE OWNER SELECTS AND PROVIDES ALL LIGHTING FIXTURES, COMPLETE WITH ACCESSORIES AND LAMPS. REFER TO THE LIGHT FIXTURE SCHEDULE ON ELECTRICAL DRAWINGS. FIXTURES PROVIDED BY OWNER SHALL BE SHIPPED TO THE SITE FOR INSTALLATION BY THE ELECTRICAL CONTRACTOR, THE CONTRACTOR SHALL SURVEY THE SHIPMENT TO VERIFY FIXTURE QUANTITIES AND DAMAGES. IN THE EVENT THAT SHIPMENT IS INCOMPLETE OR DAMAGED, THIS CONTRACTOR SHALL INFORM OWNER. AFTER THE SHIPMENT IS VERIFIED AND ACCEPTED, CONTRACTOR SHALL MOVE FIXTURE TO AN AREA OF SAFETY FOR STORAGE UNTIL THEY MAY BE INSTALLED. HE ASSUMES RESPONSIBILITY FOR THE FIXTURES UNTIL THE PROJECT IS TURNED OVER TO THE OWNER. 25. PAINTING OF ELECTRICAL CONDUITS, ETC., IF REQUIRED, WILL BE BY GENERAL CONTRACTOR. 26. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN HIS WORK AS THE JOB PROGRESSES, AND UPON COMPLETION SHALL TURN OVER TO THE TENANT A RECORD SET OF PRINTS SHOWING THESE CHANGES. 27. AT THE COMPLETION OF JOB, CONTRACTOR SHALL REPLACE ANY LAMPS THAT HAVE BURNED OUT, NEW AND EXISTING, CLEAN ALL FIXTURES, TOUCH UP ANY SCRATCHES AND REPLACE ANY FIXTURES THAT HAVE BEEN DAMAGED. 28. GUARANTEE: MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THIS CONTRACTOR'S EXPENSE. FOR THE SAME PERIOD, ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND /OR INSTALLED BY HIM. WARRANTY OF ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF PROJECT CLOSE -OUT. 29. IT IS THE INTENT THAT THE FOREGOING WORT( SHALL BE COMPLETE IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. 30. THE LOCATION OF RECEPTACLES AND FIXTURES SHOWN ON THE DRAWING IS APPROXIMATE AND THE OWNER SHALL HAVE THE RIGHT TO RELOCATE ANY RECEPTACLES OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. SYMBOL O SINGLE POLE WALL SWITCH 2 $ WALL SWITCH - DESIGNATIONS AS FOLLOWS: 2 =2 POLE 4 =4 -WAY 3 =3 -WAY P =PILOT LIGHT M =MOTOR RATED S\M rCH H= LIGHTED HANDLE DM= DIMMER MS= MOTION SENSOR SWITCH (HUBBELL #ATP1277W) GF 6 18 Fl LV +12" OD DESCRIPTION EXHAUST FAN DATA OUTLET TELEPHONE OUTLET TIMESWITCH SCALE: N/A CONDUIT UP +2" UNLESS NOTED CONDUIT DOWN CONDUIT HOMERUN UNDERGROUND CONDUIT HOMERUN CONDUIT - AS SHOWN INDICATES (1) HOT /SWITCH LEG, (1) NEUTRAL, (1) GROUND UNDERGROUND CONDUIT - AS SHOWN INDICATES (1) HOT /SWITCH LEG, (1) NEUTRAL, (1) GROUND THREE PHASE CIRCUIT - TICK MARK INDICATES (3) CONDUCTORS, (1) GROUND SINGLE PHASE CIRCUIT - TICK MARK INDICATES (2) CONDUCTORS, (1) GROUND * NOTE: 3 -WAY AND 4 -WAY SWITCHING REQUIRES ADDITIONAL CONDUCTORS FOR PROPER OPERATION. PROVIDE AS REQUIRED FOR A COMPLETE WORKING LIGHTING CONTROL SYSTEM. PROVIDE UN- SWITCHED HOT TO ALL EMERGENCY LIGHTING FIXTURES AND EXIT SIGNS. SIMPLEX RECEPTACLE - NEMA 5 -20R UNLESS NOTED OTHERWISE DUPLEX RECEPTACLE - NEMA 5 -20R UNLESS NOTED OTHERWISE DOUBLE- DUPLEX RECEPTACLE - NEMA 5 -20R UNLESS NOTED OTHERWISE RECEPTACLE DESIGNATIONS AS FOLLOWS: GFCI = GROUND FAULT INTERRUPTER WP= WEATHERPROOF S= SWITCHED - E= EMERGENCY POWER IG= ISOLATED GROUND AC =ABOVE COUNTER HEAVY DUTY RECEPTACLE - NEMA TYPE AS NOTED ON PLANS. FLOOR MOUNTED DUPLEX RECEPTACLE CEILING MOUNTED DUPLEX RECEPTACLE QUAD RECEPTACLE JUNCTION BOX LOW VOLTAGE BELL LOW VOLTAGE CHIME SUB - WOOFER SPEAKERS ELECTRICAL SYMBOLS NON -FUSED DISCONNECT SWITCH 60/3 = 60 AMP SWITCH, 3 POLE FUSED DISCONNECT SWITCH 60/3/40 = 60 AMP SWITCH, 3 POLE, 40 AMP FUSE LOW VOLTAGE 12" ABOVE FLOOR LINE OF AREA WHERE SHOWN ELECTRICAL PANELBOARD DUCT SMOKE DETECTOR 1 2 3 4 7 9 10 11 12 LCK,IG LANDLORD'S MAIN DISTRIBUTION AND MASTER METERING EQUIPMENT LOCATED IN LANDLORD'S ELECTRICAL ROOM. VERIFY LOCATION ON SITE. LANDLORD SHALL PROVIDE (4) #3/0 AND (1) #6 GROUND IN 2" CONDUIT FROM LANDLORD'S DISTRIBUTION EQUIPMENT TO TENANT SPACE. F LC1 LC1 LC1 LC2 LC2 LC2 LC2 LC3 LC LC2 17 LANDLORD PROVIDED MAIN CIRCUIT BREAKER. UTILITY METER WITHIN LANDLORD'S EQUIPMENT. COORDINATE ALL REQUIREMENTS WITH LANDLORD AND UTILITY COMPANY. CONTRACTOR SHALL EXTEND FEEDERS AND CONDUIT, AS REQUIRED, TO PANELBOARD 'HP' WITHIN TENANT SPACE. PROVIDE 225 AMP PANELBOARD 'HP' WITH 125 AMP MAIN CIRCUIT BREAKER. SEE PANELBOARD SCHEDULES FOR MORE INFORMATION. PROVIDE (3) #6 FEEDERS IN 1" CONDUIT FROM PANELBOARD 'HP' TO TRANSFORMER 'T1'. PROVIDE 45 KVA DRY TYPE TRANSFORMER WITH 480V, 3 PHASE DELTA PRIMARY TO 120/208V, 3 PHASE WYE SECONDARY. TRANSFORMER SHALL BE FLOOR MOUNTED. PROVIDE #6 GROUND IN CONDUIT FROM TRANSFORMER TO BUILDING STEEL. PROVIDE (4) #1/0, (1) #6 GROUND, AND (1) #6 ISOLATED GROUND IN 2" CONDUIT FROM TRANSFORMER 'T1' TO PANELBOARD 'PP'. PROVIDE 225 AMP PANELBOARD 'PP' WITH 150 AMP MAIN CIRCUIT BREAKER. SEE PANELBOARD SCHEDULES FOR MORE INFORMATION. PROVIDE 225 AMP PANELBOARD 'LP' WITH MAIN LUGS ONLY. SEE PANELBOARD SCHEDULES FOR MORE INFORMATION. POWER RISER DIAGRAM SCALE: N/A 13 14 FURNISH AND INSTALL TORK DZS400A (7 -DAY PROGRAMMABLE) TIME CLOCK TO CONTROL LIGHTING CONTACTORS. SET TIME AS DIRECTED BY LANDLORD AND OWNER. FURNISH AND INSTALL (3) ACO 917 LIGHTING CONTACTORS, POLES AS REQUIRED, IN STANDARD NEMA 1 ENCLOSURE. MOUNT ADJACENT TO PANEL LP. 4 HP 6 8 PP 10 LP 12 fl NOTE: THIS RISER DIAGRAM REPRESENTS (AS ACCURATELY AS POSSIBLE) THE EXISTING ELECTRICAL DISTRIBUTION SYSTEM. FIELD VERIFY ALL SIZES OF EQUIPMENT, CONDUCTORS, FUSES, ETC. SIZES SHOWN ON THIS DRAWING SHALL BE CONSIDERED A MINIMUM. ANY EXISTING EQUIPMENT CONDUCTORS, FUSES, ETC. WHICH DO NOT MEET MINIMUM SHALL BE REPLACED TO MEET MINIMUM. FUSES FOR HVAC EQUIPMENT SHALL BE PER UNIT NAMEPLATE DATA FUSE AMPACITY SHALL NOT EXCEED CONDUCTOR AMPACITY. 13 14 PANELBOARD SCHEDULES SCALE: N/A G,LCK G,LCK G,LCK EM E M,LC3 LC2 LC2 LC2 LC2 EM,LC3 LC2 LC2 LC2 LC2 LC2 ELO 0 ° v 4 0 vv M M W -1 a`� I j u_ 1-- PROJECT TEAM: Architect: Epoch Design Group, Inc. 1 155 Olivette Exec. Pkwy. Suite 100 St. Louis, MO 63132 TEL: 314.721.1340 FAX: 314.721.0344 M. E. P. & F.P. Engineer: COPYRIGHT DISCLAIMER: RANDALL A. NELSON 8016 Reeder Rd. Lenexa, KS 66214 TEL, 913- 322 -5150 FAX, 913- 322 -5155 THIS DOCUMENT IS THE PROPERTY OF EPOCH DESIGN GROUP, COPYRIGHTED M DATED, ALL RIGHTS RESERVED. AUTHORIZATION FROM EPOCH DESIGN GROUP FOR USE OF THIS DOCUMENT IS NOT TRANSFERABLE. THE RECIPIENT OF THIS DOCUMENT I5 HEREBY ADVISED THAT IT IS RELEASED FOR USE UNDER THE FOLLOWING TERMS AND CONDITIONS. THE DOCUMENT IS TO BE USED ONLY IN CONJUNCTION WITH TIES PROJECT. REUSE OF ANY PORTION OF THE DOCUMENT IN ANY OTHER CIRCUMSTANCE CONSTITUTES COPYRIGHT INFRINGEMENT. THE DOCUMENT IS FOR DESIGN INTENT AND INFORMATION ONLY, AND DOES tigi CONSTITUTE AS -BUILT CONDITIONS. THE RECIPIENT RETAINS THE OBLIGATION TO VERIFY THE CONDITIONS OF THE SUBJECT PROPERTY MID TO COMPLETELY COORDINATE ALL DIMENSIONS, FABRICATION METHODS, RELATED AND INTEGRATED SYSTEMS, ETC, WITH RESPECT TO ALL ASPECTS OF THE WORK. EPOCH DESIGN GROUP MAKES NO WARRANTY AS TO THE SUITABILITY OF THE DOCUMENT FOR THE RECIPIENTS INTENDED USE. THE RECIPIENT SPECIFICALLY AGREES TO WAIVE AND TO INDEMNIFY AND DEFEND ANY AND ALL CLAIMS AGAINST EPOCH DESIGN GROUP, ITS CONSULTANTS, ANY OF ITS RELATED ENTITIES, VENDORS, OR CON R C OR3 FOIL MIY LOSS INCURRED A S RESULT OF PR P 4 IACRROPERy'1}SF,IP THIS DOCUMENT. THE RECIPIE GREF T LA1 pR DE,£JI:j �OYHIi DOCUMENT UPON C ETIQ.L7 k LAN 6Pa WO ORMED 5911 ION THIS PROJECT. PROJECT TITLE: SHEET TITLE: PROJECT NO.: 07073 DRAWN BY: LBS ISSUE DATE: 11/07/07 0 uJ t O Z ,- `n w Uj O = iO Z h- ~ Z cv• w v)ON 111 tn -"( a. O RECEIVED CITY OF TIJKVUILA DEC 1 1 2007 P�HIVl1T CEN I ER W (I) No.41 Revision Description Date ELECTRICAL SPECIFICATIONS, PANELS, AND RISER SHEET NUMBER: E4.0