Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL07-780 - WESTFIELD SOUTHCENTER MALL - ESCAPE OUTDOORS
ESCAPE OUTDOORS 817 SOUTHCENTER MALL ELO7-780 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Permit Center Authorized Signature: Signature: Print Name: doc: EL -4/07 City,if Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 817 SOUTHCENTER MALL TUKW ESCAPE OUTDOORS 817 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA YEN NGUYEN 105 S MAIN ST, STE 323 , SEATTLE WA Contractor: Name: H & M ELECTRIC INC Address: 918 CEDAR , MARYSVILLE WA Contractor License No: HMELEI *077KR DESCRIPTION OF WORK: TENANT IMPROVEMENT: INSTALL NEW ELECTRICAL PANELS AND CIRCUITS. Value of Electrical: $40,000.00 Fees Collected: $922.50 Type of Fire Protection: SPRINKLERS /AFA National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this •ermit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or y�'- erformance of work. I a authorized to sign and obtain this electrical permit. /✓�2 c- jJ •2rS -W ELECTRICAL PERMIT ,Ata Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 624 -4222 Phone: 360 - 658 -0501 Expiration Date: 05/19/2009 ELO7 -780 05/07/2008 11/03/2008 Date: k5 - N k Date: c„/ ? — of This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. EL07 -780 Printed: 05-07 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: 1: ** *ELECTRICAL * ** ESCAPE OUTDOORS City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 817 SOUTHCENTER MALL TUKW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL07 -780 ISSUED 12/13/2007 05/07/2008 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: doc: Cond -Elec G Print Name: PE /'PC/ C• IU E 2 l S 0 i/ Date: 3'.r 7— od EL07 -780 Printed: 05-07 -2008 Site Address: (Dot 1.44OA � Ma Tenant Name: E S r P © SV`% Property Owners Name: Mailing Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tkwila. wa. us CONTACT PERSON - Who do we contact when your permit is ready to beissued Name:y,Q41 k) C U Mailing Address: Q E -Mail Address: (\QM � PjJIDA 6. O.yTjtel -PAA ELECTRICA CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): SA 0, OCTO Scope of Work (r lease • rovide detail information): Will service be altered? Yes [� No Type of Use: a — c!/ (J Type of work: New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: Puget Sound Energy ❑ Seattle City Light H:Upplications\Fonns- Applications On Line \4 -2007 - Electrical Permit Application.doc bit ❑ Service Change ❑ Fire Alarm ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 43 I-, 12.0 ^ CSO I Q Suite Number: 1440 Floor: New Tenant: Yes ❑..No City State Day Telephone: /.c t, — 4,2_14 - S- - w City State Zip Fax Number: 20 4, - 2y - y 9 22- State Zip Zip Adding more than 50 amps? ❑ Yes ❑ No ❑ Remodel ❑ Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) PERMIT APPLICATION NOTE Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR TRICAL CONTRACTOR: Signature: Print Name: Mailing Address: 4 I70 13r/ LZi — S54 MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea Date: /21/3A Day Telephone: 6 Y3 6� >/e tis w 52300'1 City State Zip Date Application Accepted: Date Application Expires: apt (411) Staff Initials: � A H:\Applications\Forms- Applications On Line\4 -2007 - Electrical Permit Appliation.doc bh Page 2 of 2 Parcel No.: 6364200010 Permit Number: EL07 -780 Address: 817 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 12/13/2007 Applicant: ESCAPE OUTDOORS Issue Date: Receipt No.: R08 -01518 Initials: WER Payment Date: 05/07/2008 02:23 PM User ID: 1655 Balance: $0.00 Payee: H & M ELECTRIC INC TRANSACTION LIST: Type Method Descriptio Amount ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Payment Check 025718 738.00 RECEIPT Account Code Current Pmts 000.322.101.00.0 738.00 Total: $738.00 Payment Amount: $738.00 2102 05/07 9711 TOTAL 738.00 doc: Receiot -06 Printed: 05-07 -2008 RECEIPT NO: R07 -02752 Initials: JEM User ID: 1165 Payee: URBAN TRADING, LLC SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http.• / /www.ci.tukwila.wa.us D07 -461 827.85 D07 -462 45.88 EL07 -780 184.50 M07 -276 70.97 TOTAL: 1,129.20 SET RECEIPT SET ID: S000000920 SET NAME: Tmp set/Initialized Activities TRANSACTION LIST: Type Method Description Amount Payment Check 1001 1,129.20 TOTAL: 1,129.20 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES Account Code Current Pmts 000.345.832.00.0 184.50 000/345.830 944.70 TOTAL: 1,129.20 Payment Date: 12/13/2007 Total Payment: 1,129.20 5996 12/13 9710 TOTAL 1129.20 Project: � � j - /,tT ` �V'(�0 S (k Type of Ins loa Address: c'-f M Date Called: Special Instructio s: Date Wanted: // .m. Requester: I Phone No: i INSPECTION RECORD Retain a copy with permit . 1 ` INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION a- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 367.0 COMMENTS: K de- ry\i44.. Approved per applicable codes. Corrections required prior to approval. Inspector: Date: pzi ar n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Pr IG ,sc, — dd 4$u i Ao ( Type O/ %n . �r' / Addre V1> SL /4ifLL Date Called: Special Instructions: Date Wanted: a m Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431- 0 OMMENTS: /9 O/4 - //vxz-- / bV, /4Jo / 494,-) 2 )L of En 644'cy 4/64' r/1/ f )gE )Af, proved per applicable codes. El Corrections required prior to approval. Jl nsPyr: 6-Tetcoa Date /� f / $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project: SC � 6 U u � Ll Type of Inspection: � D � A ddress : T i l ((//��a Date Called: Special Instructions: Date Wanted: 6/Z0 a.m. p.m. Requester: Phone No: 2- INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6-°7— Ire) 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. Approved per applicable codes. COMMENTS: Kc - cA,cIA-ea -+dcA RE J'e F0 7_77/ yc�'o�1 �JA) t el V �/ .7 . ReLbC `fkJ 1 Inspector:f . 6Dij t nl El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. -Call to schedule reinspection. (Receipt No.: 'Date: .6-tov=-etg- Corrections required prior to approval. I 0at OL2 0, Project* 0 Type of Inspection: 700 Address: N Date Called: Special Instructions: Date Wanted: 6 l! a.m. Requester: Phone No: INSPECTION RECORD Retain © with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 z_ ti -01-. ?o Approved per applicable codes. Corrections required prior to approval. COMMENTS: PN� D(. - vJA4/5 X Sti gfilAtA Inspector: (Date: 0 61 / 0. fJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project: t 4Gfi(E G rmo/1.S Type of Inspection: 7M 7 A ress: � /J, Date Called: Special Instructions: Date Wanted: 4/ a Requester: Phone No: 4/ 60 7-75 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 OMMENTS: *- //UP- 6 -W----riezz_et - - , 4 - pproved per applicable codes. El Corrections required prior to approval. I lnspe a x ,&7/4 I U $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Pro'ect: f�/°� avT,�/, /lLS Type of Inspection: 700,7 AO ) ress: / f 7 JOK A1 4 / 1 7Aw Ii Date Called: Special Instructions: Date Wanted: 67, p 2 a Requester: Phone No: INSPECTION RECORD Retain a copy with permit fro- 76 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 17 ' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 MMENTS: fie) 0/4 Mu s41 A tads — Titf14)6/AV Aviy� LAM"- - /wiz shat SAt t /1444 'Ins proved per applicable codes. El Corrections required prior to approval. G1 YJG/ en/4 Dale /x $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: IDate: 0 Project:6 /„� �� I C Type of Inspection: 70o3 Address: g l 1 1 + 41 4/ Date Called: Special Instructions: Date Wanted: 52l 41 Requester: Phone No: I El Approved per applicable codes. Corrections required prior to approval. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: yA voit vitt14.5 'Inspector: -- 13ex Date: oS21 fo El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: 607 -l PERMIT NO. (206)431 -3670 Projec GA D �ObiCS U Type of Inspe - -� d � O Z Address: � A " �� � " Date Called: Special Instruction : Date Wanted: 5 (0 I p. m. Requester: Phone No: INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IP- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 -3670 pproved per applicable codes. El Corrections required prior to approval. COMMENTS: — CAfte4 r z� Date: 05 .A/4 0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Inspector: J; &JOS (Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit 601- -ND COMMENTS: Type of Inspection: td/UI Ve O W d r s: / 7 cirr,/4i / t / lla. Date Called: 7 i Fm pm. L- oc4T' /) 6-Oi2 N.M. G1 AMR / 4E4 /Pi — Rfifiri TV CL 6<4 /41 Phone No: P ect: /] ��.lf7vXj/z Type of Inspection: d r s: / 7 cirr,/4i / t / lla. Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: i INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 'Inspector Cw7 -7L proved per applicable codes. El Corrections required prior to approval. "/k(7 #. 2 / 0 , 5 El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Main Floor Ll Adjustable Downlight - 1L 50W MR16 8 50.0 400.0 Main Floor L2 Adjustable Quad Downlight - 4L 50W MR16 8 200.0 1600.0 Main Floor L3 Hanging Pendant - 3L 60W 3 180.0 540.0 Bldg. (by facade) BIdg. (by Perim) L4 Hanging Pendant - IL SOW 6 50.0 300.0 -.si .Aa L5 2x4 Recess Prismatic 2L -F32T8 5 60.0 300.0 L6 Compact Fluorescent Downlight - 26W TRT 1 26.0 26.0 L7 3' - Fluorescent Strip 1L -F25T8 4 28.0 112.0 18 4' -0" Fluorescent Strip 1L -F32T8 2 30.0 60.0 L9 LED Strip Cove Lighting 1 42.0 42.0 XP White Polycarbonate Exit Sign 2 5.0 10.0 XL Surface Mount Emergency "Bug -eye" Wall Pack 2 11.0 22.0 Location (floor /room no.) _ - _ Occupancy Description Allowed Watts per ft " Area in ft' Allowed x Area Main Floor Retail 1.50 1422.7 2134.1 Main Floor Office 1.00 365.3 365.3 Main Floor Additional Retail Allowance (per WSEC 15 -1) 1.50 1485.7 2228.6 Project Info Project Address Escape Outdoors at Southcenter Mall Date REVIE IE �� 1460 Southcenter Parkway For flittf� T ar>�nOM NFPA 70 - NEC (�j� � JAN - 7 2UUY (,/ / Tukwila, WA. 98188 -2886 Applicant Name: DeStephano Consulting, Inc. Applicant Address: 170 Bellevue Square Bellevue WA, 98004 Applicant Phone: (425) 467 -6643 Location Description Mowed Watts per ft or per If Area in ft' Allowed Watts (or If for perimeter) x ft (or x If) Covered Parking (standard paint) 0.2 W/fl Covered Parking (reflective paint) HEULIVEU CITY OF TUKWILA 0.3 W/ft Open Parking DEC 1 3 2n07 0'2 Witt2 Outdoor Areas 0.2 W/fl Bldg. (by facade) BIdg. (by Perim) hill 1 .1 i R - 1 ] 0.25 W/ft2 1 •l : L1' &'I 1 -.si .Aa .�� I/ 2001 Washington State Nonresidential Energy Code Compliance Forms Project Description Maximum Allowed Lighting Wattage (Interior 2001 Washington State Nonresidential Energy Code Compliance Form Lighting Summary LTG -SUM " From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Proposed Watts may not exceed Total Allowed Watts for Interior Maximum Allowed Lighting Wattage (Exterior ▪ New Building Q Addition ® Alteration Refer to WSEC Section 1513 for controls and commissioning .kme 2001 - KIM Or Tukwila NG DIVISIO Compliance Option o Prescriptive • Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box) ▪ No changes are being made to the lighting 0 Less than 60% of the fixtures are new, and installed lighting wattage is not being increased Total Allowed Watt4 4727.9 Notes: 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default table In the NREC Technical Reference Manual may also be used 2. Include exit lights unless less than 5 watts per fixture. Proposed Lighting Wattage (Interiarl all fixtures. For exempt fighting, not exception and leave Watts/Fixture blank. Total Proposed Wa 3412.0 Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 2001 Washington State Nonresidential Energy Code Compliance Form 'Bldg. (by perim) I 7.5 W/If Note: for building exterior, choose either the facade area or the perimeter method, but not both) Total Allowed Watts Use mfgr listed maximum input wattage. For fixtures with hard -wvea oanasts only, the default table in the NREC Technical Reference Manual may also be used. Proposed Lighting Wattage (Exterior) Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts TABLE 15 -1 Unit Lighting Power Allowance (LPA) Use' LPA` (W /sf) Use' LPA` (W /sf) Painting, welding, carpentry, machine shops 2.3 Police and fire stations 1.5 Barber shops, beauty shops 2.0 Atria (atriums) 1.0 Hotel banquet/conference/exhibition hall''` 2.0 Assembly spaces ° , auditoriums, gymnasia ° , heaters 1.0 Laboratories 2.0 Group R -1 common areas 1.0 Aircraft repair hangars 1.5 Process plants 1.0 Cafeterias, fast food establishments 1.5 Restaurants/bars 1.0 Factories, workshops, handling 1.5 Locker and /or shower facilities 0.8 Gas stations, auto repair shops 1.5 Warehouses ', storage areas 0.5 Institutions 1.5 Aircraft storage hangars 0.4 Libraries' 1.5 Retail retail banking 1.5 Nursing homes and hotel /motel guest rooms 1.5 Parking garages See Section 1532 Wholesale stores (pallet rack shelving) 1.5 Mall concourses 1.4 Plans Submitted for Common Areas Only' Schools buildings (Group E occupancy only), school classrooms, day care centers 1.35 Main floor building lobbies' (except mall concourses) 1.2 Laundries 1.3 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools hospitals, pitals, institutions, museums, banks, churches) ' ' 1.2 Footnotes for Table 15 -1 Lighting Summary (back) LTG-SUM 2001 Washington State Nonresidential Energy Code Compliance Forms Prescriptive Spaces Qualification Checklist Note: If occupancy type Is "Other and fixture answer is checked, the number of fixtures In the space Is not limited by Code. Clearly Indicate these spaces on plans. If not qualified, do LPA Calculations. Occupancy: Q Warehouses, storage areas or aircraft storage hangers d Other Lighting Fixtures: Check here if at least 95% of fixtures in the space meet all four criteria: 1. Fixtures are fluorescent, non - lensed, with only one or two lamps, and 2. Lamps are T -1, T -2, T-4, T -5, T-6, T -8 3. Lamps are 5 -50 Watts, and 4. Ballasts are electronic ballasts 5. Exit lights < 5 watts/fixture 6. Screw -in compact fluorescent fixtures do not qualify In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Includes pump area under canopy. 7) In cases in which a lighting plan is submitted for only a portion of a floor, a Unit Lighting Power Allowance of 1.35 may be used for usable office floor area and 0.80 watts per square foot shall be used for the common areas, which may include elevator space, lobby area and rest rooms. Common areas, as herein defined do not include mall concourses. 8) For the fire engine room, the Unit Lighting Power Allowance is 1.0 watts per square foot. 9) For indoor sport tournament courts with adjacent spectator seating, the Unit Lighting Power Allowance for the court area is 2.6 watts per square foot. 10) Display window illumination installed within 2 feet of the window, lighting for free - standing display where the lighting moves with the display, and building showcase illumination where the lighting is enclosed within the showcase are exempt. An additional 1.5 w/ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 1) 2001 Washington State Nonresidential Energy Code Compliance Form June 2001 - KJM 2001 Washington State Nonresidential Energy Code Compliance Form Lighting Power Allowance Adjustments LTG -LPA 2001 Washington State Nonresidential Energy Code Compliance Forms Adjusted Lighting Power Allowances (Interior) "" From Table 15-1 based on exceptions listed in footnotes June 2001 - KJM Project Address 'Escape Outdoors at Southcenter mall 'Date 12/11 /2007 Use this form if you are daiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15-1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft Carry the Adjusted LPA to the corresponding "Allowed Watts per ft 2 " location on LTG -SUM. Location (floor /room no.) Occupancy Description Allowed Watts per ft Ceiling Height for this room Ceiling Height limit for this exception *" Adjusted LPA Watts per ft2 Lighting Permit Plans Checklist 2001 Washington State Nonresidential Energy Code Compliance Forms LTG -CHK June 2001 - KJM Project Address Escape Outdoors at Southcenter mall 'Date 12/11/2007 The following information is necessary to check a lighting permit application for compliance with the lighting requirements in the 1994 Washington State Nonresidential Energy Code. Applicability I Code I Component Information Required on Plans Notes LIGHTING CONTROLS (Section 1513) 1513.1 Local control /access Schedule with type, indicate locations 1513.2 Area controls Maximum limit per switch 1513.3 Daylight zone control Schedule with type and features, indicate locations vertical glazing Indicate vertical glazing on plans overhead glazing Indicate overhead glazing on plans 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location (a) timer w /backup Indicate location (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location 1513.6.1 (a) occup. sensors Schedule with type and locations 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans 4 1513.7 Commissioning Indicate requirements for lighting controls commissioning n.a. Lighting Sum. Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture I I Elec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I 2001 Washing ton State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: Lighting - General Requirements 1513 Lighting Controls. Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a twenty ampere circuit loaded to not more than eighty percent. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than five percent of footprint for footprints over 100,000 square feet. 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight -or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition, and Specialty Lighting Controls: All display, exhibition, or specialty lighting shall be controlled independently of general area lighting. 2001 Washin ton State Nonresidential Ene • Code Com•liance Form Lighting Permit Plans Checklist LTG -CHK 2001 Washington State Nonresidential Energy Code Compliance Forms June 2001 - KJM 1513.5 Automatic Shut -Off Controls, Exterior: Exterior lighting not intended for 24 -hour continuous use shall be automatically switched by timer, photocell, or a combination of timer and photocell. Automatic time switches must also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. 1513.6 Automatic Shut -Off Controls, Interior: Office buildings greater than 5,000 sq. ft. and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Automatic controls may be an occupancy sensor, time switch, or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated, or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off" feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a) is readily accessible; b) is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; and c) is manually operated; d) allows the lighting to remain on for no more than two hours when an over -ride is initiated; and e) controls an area not exceeding 5,000 square feet or 5 percent of footprint for footprints over 100,000 square feet, whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu/h Total CFM OSA CFM or Econo? SEER or EER IPLV Location FPT -1 TITUS DTQS -6 5 KW 1400 Econo Ceiling FPT -2 TITUS DTQS -2 1.5 KW 300 Existing RFt ,F C IVED 100.000 FPT - 2 TITUS DTQS - 2 300 Econo C1TY OF TUKWIIP Ceiling 13[0:(: 1 Existing t EhvitT CL-vial Fan Equipment Schedule Equip. ID Brand Name' Model No. CFM sp HP /BHP Flow Control Location of Service N/A FPT -1 TITUS DTQS -6 5 KW 1400 100.000 FPT -2 TITUS DTQS -2 1.5 KW 300 RFt ,F C IVED 100.000 C1TY OF TUKWIIP 13[0:(: 1 oFr, 1 a 2007 Heating Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu/h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency FPT -1 TITUS DTQS -6 5 KW 1400 100.000 FPT -2 TITUS DTQS -2 1.5 KW 300 RFt ,F C IVED 100.000 C1TY OF TUKWIIP oFr, 1 a 2007 t EhvitT CL-vial Project Info Project Address Escape Outdoors at Southcenter Mall a att E3� 2 CC 10E 14060 Southcenter Parkway nnnngg ' a I E' r � ' r f IAI Tukwila, WA. 98188 -2886 NFPA 70 - NEC Applicant Name: Destephano Consulting, Inc. Applicant Address: 17o Bellevue Square Bellevue WA, 98004 JAN - 7 2000 Applicant Phone: (425) 467 -6643 t Mechanical Summary MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. Indudes Plans 2006 Washington State Nonresidential Energy Code Compliance Form Tenant improvement. Add Fan Terminal Units and d ifiotl 4 Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Revised July 2007 Of Tukwil it IIIVIS Compliance Option ® Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 'If available. 2 As tested according to Table 14 -1A through 14-1G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). FILE COP ON System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? ❑ Packaged sys? ❑ <20,000 Btuh? ❑ Economizer included? If Heating Only: ❑ <5000 cfm? ❑ <70% outside air? Mechanical Summary (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only 2006 Washington State Nonresidential Energy Code Compliance Form Reference Section 1421 otal Ca • . wo economize <240,000 Btuh r 10 %? Heating/Cooling or Cooling Only Yes Reference S ection 1423 • Use Complex Systems (section 1430) !Complex Systems I Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical - Complex Systems 2006 Washington State Nonresidential Energy Code Compliance Forms Checklist MECH -COMP Revised July 2007 Project Address Escape Outdoors at Southcenter Nall Date 12/12/2007 The following additional information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH- CHK checklist for additional system requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptable alternative. For Building Department Use Applicability I (yes, no, n.a.) Code I Section Component Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY 1431.1 Field assem. sys. Provide calculations 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans 1432.2.1 Air system reset Indicate automatic reset 1432.2.2 Hydronic System Indicate automatic reset, cooling tower, & heat pump loop valves 1433 Air Economizer Indicate economizer on equipment schedule or provide calculations to justify exemption and demonstrate 10% higher efficiency for equipment with out economizer. 1433 Water Economizer Indicate water economizer and provide calculations if 1433 Exception 2 is utilized 1434 Separate air sys. Indicate separate systems on plans 1435 Simul. htg. & cig. Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified 1436 Heat recovery Indicate heat recovery on plans; complete and attach heat recovery calculations 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp, rpm, efficiency 1438 Variable flow sys. Indicate variable flow on fan and pump schedules 1439.1 Kitchen Hoods Indicate uncooled and unheated make -up air 1439.2 Fume Hoods Indicate VAV, unheated /uncooled or heat rec. makeup no is circled for any question, provide explanation: Decision flowchart Use this flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for more complete information on the requirements. ( Start Here ) Section 1432.2.2 Hot Water Supply Temperature Reset Required • Section 1411.1 Equipmen Eftidency Shad Meet Tables 14-1A through 14-1G Yes • 1411.1 Intermittent Ignition Device & Power Venting or Damper. If input 225,000 Btuh then 1412.8 Modulating or Staged Combustion Controls Required 2006 Washington State Nonresidential Energy Code Compliance Form Yes • 1411.1 0.75% Maximum Jacket Loss Section 1431.1 Calculations of Total On-Site Energy Input & Ouput Required (continued on back) Section 1432.2.1 Supply Alr Reset Controls Required Yes No 2006 Washington State Nonresidential Energy Code Compliance Forms Yes 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical - Complex Systems (back) MECH -COMP Section 1438 50% Effective Heat Recovery Required Yes No DONE Yes♦ Section 1435 Zone Controls Must Reduce Supply Air Quantity Before Reheating/Recooling Section 1439.1 No Heating or Cooling for at Least 50% of Make -up Air No-* Section 1433 Economizer Required Yes Section 1437 Motors Must Meet Efficiencies in Table 14-4 Section 1438 Variable Flow Devices Required Section 1439.2 One Required: a. 50% VAV Exhaust & Make -up b. 75% Direct Makeup w/ Tempering Only c. Heat Recovery per 1436 d. Constant Volume w/ < 50fpm Face Velocity Yes Revised July 2007 Open Motors dosed Motors 3.600 I 1,800 I 1,200 3,600 I 1,800 I 1,200 Efficiency ( %) Efficiency ( %) - 82.5 80.0 75.5 82.5 80.0 82.5 84.0 84.0 82.5 84.0 85.5 84.0 84.0 85.5 84.0 84.0 86.5 84.0 86.5 86.5 85.5 87.5 87.5 85.5 87.5 87.5 87.5 87.5 87.5 87.5 88.5 88.5 88.5 89.5 89.5 88.5 89.5 90.2 89.5 89.5 89.5 89.5 91.0 90.2 90.2 91.0 90.2 90.2 91.0 91.0 90.2 91.0 90.2 91.0 91.7 91.7 91.0 92.4 91.7 91.0 92.4 92.4 91.0 92.4 91.7 91.7 93.0 93.0 91.7 93.0 93.0 92.4 93.0 93.0 92.4 93.0 93.0 93.0 93.6 93.6 93.0 93.6 93.6 93.0 94.1 93.6 93.0 94.1 936 93.0 94.1 94.1 93.6 94.5 94.1 93.6 94.5 94.1 94.5 94.5 94.1 93.6 95.0 94.5 94.5 95.0 95.0 94.5 _ 95.0 94.5 95.0 95.0 95.0 Electric Motors MECH -MOT 2006 Washington State Nonresidential Energy Code Compliance Forms Project Address Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). Motor No. or Location Minimum Nominal Full -Load Efficienc Synchronous Speed (RPM) HP 1.0 1.5 2.0 3.0 5.0 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 HP 2006 Washin ton State Nonresidential Ene • Code Corn • Hance Form Escape Outdoors at Southcenter Mall Type (opeNclosed) Description of Application or Use Date For Building Department Use Synch. Speed 12/12/2007 Revised July 2007 Min.Nom. Full load Efficiency Exceptions: 1. Motors in systems designed to use more than one speed of a multi-speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14- I A or 14-1 B) . 3. Motors that are an integral part (i.e. not easily removed and replaced) of specialized process equipment (i.e. equipment which requires a special motor, such as an explosion - proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (i.e. if the only U.L. listing for the equipment is with a less- efficient motor and there is no energy - efficient motor option). For motors claiming an exception, list motor and note which exception applies. Mechanical Permit Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Escape Outdoors at Southcenter Mall 'Date 12/12/2007 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability , es, no, n.a.) I Code I Section 'Component I p Information R wired I eq I Location I on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& cig. List heat pumps on schedule n.a. 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans ml . 0 yes 1412.2 Deadband control Indicate 5 degree deadband minimum SPECS n.a. 1412.3 Humidity control Indicate humidistat yea 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types EXIST n.a. 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage n.a. 1412.4.2 Optimum Start Indicate optimum start controls n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n. a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans SPECS 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans n.a. 1423 Economizers Equipment schedule EXIST 1413 Air economizers n.a. 1413.1 Air Econo Operation Indicate 100% capability on schedule EXIST n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate clg load & water econoe & cig tower performance n.a. 1413.3 Integrated operation Indicate capability for partial cooling n.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary rn . 0 yes 1414.2 Duct insulation Indicate R -value of insulation on duct rsl . o n.a. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements yes 1416.2.1 Commissioning Provide commissioning plan SPECS yes 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing SPECS yes 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training SPECS yes 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report SPECS n.a. 1434 Separate air sys. Indicate separate systems on plans ! Mechanical Completed and attached. Equipment schedule with types, ! Summary Form Linput/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. n.a. 1441 Elec. water heater Indicate R -10 insulation under tank n.a. 1442 Shut -off controls Indicate automatic shut -off n.a. 1443 Pipe Insulation Indicate R -value of insulation on piping n.a. 1452 Heat Pump COP Indicate minimum COP of 4.0 n.a. 1452 Heater Efficiency Indicate pool heater efficiency n.a. 1453 Pool heater controls Indicate switch and 65 degree control n.a. 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form no Is circled for any question, prow ae explanation: 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown In Table 14 -1A through 14-1G. If a nationally recognized certification program exists for a product covered in Tables 14-1A through 14 -1G, and it indudes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings 225,000 Btu/h (85 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with Input ratings > 225,000 Btu/h (85 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F Inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (8,828 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High -Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 f12, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or e. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1438. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 efm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 efm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 85,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413,4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 248 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.8 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system dm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating Interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation Installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by Insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown In Table 14 -1A through 14-1G. If a nationally recognized certification program exists for a product covered in Tables 14-1A through 14 -1G, and it indudes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings 225,000 Btu/h (85 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with Input ratings > 225,000 Btu/h (85 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F Inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (8,828 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High -Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 f12, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or e. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1438. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 efm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 efm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 85,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413,4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 248 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.8 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system dm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating Interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation Installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by Insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying 2006 Washington State Nonresidential Energy Code Compliance Form 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2. are isolated from the exterior with an automatic shut -off damper complying air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating Is being used through visual means (e.g., LED indicators). 1412.8 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btulh shall have modulating or staged combustion control. 000 EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14-5 requirements. Other ducts and plenums shall be thermally insulated per Table 14-5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14-8. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -28) 1418 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) Project Name: Escape Outdoor Prepared by: Air System Sizing Summary for Office/Storage 12/03/2007 03:20PM Air System Information Air System Name. Office/Storage Equipment Class UNDEF Air System Type .. SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM .. Sum of space airflow rates Space CFM ..._______ Individual peak space loads Central Heating Coil Sizing Data No central heating coil loads occurred during this calculation. Hourly Analysis Program v.4.3 Number of zones .1 Floor Area 500.0 ft Location . Seattle IAP, Washington Calculation Months Sizing Data Central Cooling Coil Sizing Data Total coil load 0.9 Tons Load occurs at Feb 0000 Total coil load 11.3 MBH OA DB / WB 55.8 150.0 'F Sensible coil load . 8.5 MBH Entering DB / WB 77.3 166.8 •F Coil CFM at Feb 0000 .................________ 456 CFM Leaving DB /WS 59.8 / 58.8 •F Max block CFM _456 CFM Coil ADP • 57.9 'F Sum of peak zone CFM 456 CFM Bypass Factor 0.100 Sensible heat ratio . 0.751 Resulting RH .58 To ft 531.2 Design supply temp. 58.0 'F STU/(hr-ft ........ ..................._ ______ ....... _. 22.6 Zone T-stat Check ..... _ ___.1 of 1 OK Water flow @ 10.0 'F rise 2.26 gpm Max zone temperature deviation . 0.0 IT Supply Fan Sizing Data Actual max CFM . 456 CFM Fan motor BHP 0.00 BHP Standard CFM _449 CFM Fan motor kW 0.00 kW Actual max CFM/ft 0.91 CFM/ft Fan static 0.00 in wg Outdoor Ventilation Air Data Design airflow CFM 0 CFM CFM/person 0.00 CFM/person CFM/ft 0.00 CFM/ft Jan to Dec Calculated RECEIVED CITY OF TUKWILA DEC 1 3 2007 PEI-tivilT FILE COPY 4 601 - 1'6 Page 1 of 67 :'. . :. ...:.: .... ai , . s ::.:.' . ��: i^'r..Jy ":;: > r_ : �u'�..�Yi : ''�i <,;; - r.t,� �.'•.�j�I:�.'.001:$+1G _. ', : -- nri ,:.:;�,s..pl���'�._N A :-6: s e' {Y "'` Y3 ,YL A#T 00.409° . l\;'D `.' % = :55:8'F / 50:0 } l id, - DAT AA.:DES HTG I9N0!;QA f . Q !fig T E�.1,�bAD$ :.�. �' t., ,.:. - _::. ::..: :a : .. ` „D�etatls �::Senstbfe - � (B� Late B (TUfi�I >;'� N�a-S =`; is ... nta.. ens .. ViTtgh, tit ...0 **1 ....I Window 8 Skylight Solar Loads Ott' 0 - 0 ft - - Wall Transmission 0 ft • 0 - 0 ft 0 - Roof Transmission 0 W 0 - 0 ft2 0 - Window Transmission 0 ft 0 - 0 ft2 0 - Skylight Transmission 0 ft 0 - 0 ft 0 - Door Loads 0 ft 0 • 0 ft 0 - Floor Transmission 0 ft 0 • 0 f 2 0 - Partitions 0 ft 0 • 0 ft 0 - Ceiling 0 ft 0 - 011 0 - Overhead Lighting 600 W 2047 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 600 W 2047 - 0 0 - People 8 2240 2160 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 30% 130% 1900 648 30% 0 0 ( ' 'Zone. ds :?: : 8234 2808 _ T st'; , :, 0. Zone Conditioning - 8488 2808 - 0 0 Plenum Wall Load Plenum 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Retmn Fan Load 456 CFM 0 - 456 CFM 0 - Ventilation Load 0 CFM 0 0 0 CFM 0 0 Supply Fan Load 456 CFM 0 - 456 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - Total:System entral Cooling Coil - 8486 2809 - 0 0 Central Heating Coil - 0 - - 0 - ....,.o. nditioni ' :.' ...::` °.:” 8486:. ': = r1# - • . -...: :. . . . . .. .. ...: '. . . ...:. <- . >...,..... tu G Sat tft9 e� ' lve aralues are loads .loads ov:< !rod. x ,;. :.< ;= o itnre valusss�''1it .ao : ads ;:.` ;: ,:i " �'�..,.�N " alive :values a�clg��oads>�'. � .... e9 Air System Design Load Summary for Office /Storage Project Name: Escape Outdoor Prepared. by 12/03/2007 03:16PM Hourly Analysis Program v.4.3 Page 1 of 1 ......... ...:' .....: T ACE e7!:;.. : "Zo 1r.. ABI.�.'1t�:�<:�0!�f�QIJE�T °GOADS FOR SPACE �tor�g . ZONE n4 . . ,.::... � DESIGN COOLING •'• .. • OES[GLV;NEi4 i :.... ,.,.:,,.. ..:... • •. ..a' a . ,:.,:.• ' X530 � fiNB::': /.48.8 OC CUPIED t•STPIT 15:6-4F. ` ' .. NEATLNG. HEATING DALt Fa•19:2'F ... -•..- OCCUPIED'T -S AI.7Q ' :.... '1,' ; ' ::::. r ...:. , r; . .. rai �,a �..... .... -... . ,`'Y• e�ii- �::•':.� . ._� :•;:.::. . .... ... •: <:.i: �'• ; Seilslple :�:nt8r�t � - :`.e.: ..:�$- rt Ie '�.atteflt $ . C � ;° - :::;Detaii B: (BTU/hr) Details : ' t7l0) (BTU/hr) Window & Skylight Solar Loads 0 ft 0 - O ft. - - Wall Transmission 0 ft' 0 - 0 ft 0 - Roof Transmission 0 ft 0 - 0 ft 0 - Window Transmission 0 ft 0 - 0 ft. 0 - Skylight Transmission 0 ft' 0 - 0 ft2 0 - Door Loads 0 ft 0 • 0 0 0 - Floor Transmission 0 ft 0 - 0 ft. 0 - Partitions 0 ft! 0 - 0 ft. 0 - Ceiling 0 ft 0 - 0 ft= 0 - Overhead Lighting 600 W 2047 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 600 W 2047 - 0 0 - People 8 2240 2160 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 30% / 30% 1900 648 30% 0 0 ,, Total': Zone Loads is? :: ,: :; ::::::.� ..... 8235 2808 :: -. TABLEa 1 6. •• _ t±_NYELQQE;LOADS FOR SPACE.. ".: Office /Storage" °lN ZONE "Zone`? -' '. >:: .::::::'...:: :; r . .. Area • ` VaCu` - s "S ilo e' S SOLAR . : :T#CS' ." - (ft.) (BTIU(hr fer ` <�aef : ' t7l0) (BTU/hr) :' Project Name: Escape Outdoor Prepared by: Space Design Load Summary for Office/Storage 12/03/2007 03:10PM Hourly Analysis Program v.4.3 Page 1 of 1 Air System Sizing Summary for Retail Project Name: Escape Outdoor Prepared by: 12/03/2007 03:12PM Air System Information Jr System Name . Retail Equipment Class . UNDEF Air System Type SZCAV Number of zones 1 Floor Area 1485.0 ft Location Seattle IAP, Washington Sizing Calculation Information Zone and Space Sizing Method: Zone CFM . Sum of space airflow rates Calculation Months Jan to Dec Space CFM Individual peak apace loads Sizing Data Calculated Central Cooling Coil Sizing Data Total coil load 3.6 Tons Load occurs at Jan 2100 Total coil load 42.7 MBH OA DB / WB .. 58.21 50.4 'F Sensible coil load _ 28.8 MBH Entering DB / WB ---------- 77.3 1 67.7 •F Coil CFM at Jan 2100 1541 CFM Leaving DB / WB 59.8 / 58.9 °F Max block CFM 1541 CFM Coil ADP 57.8 °F Sum of peak zone CFM 1541 CFM Bypass Factor 0.100 Sensible heat ratio 0.674 Resulting RH _61 % ft'/Ton 417.2 Design supply temp. 58.0 'F BTUghr-ft _ ... 28.8 Zone T-stat Check ..__ _ _ .... ___ 1 of 1 OK Water flow 42 10.0 °F rise 8.55 gpm Max zone temperature deviation 0.0 'F Central Heating Coil Sizing Data No central heating coil loads occurred during this calculation. Supply Fan Sizing Data Actual max CFM 1541 CFM Fan motor BHP 0.00 BHP Standard CFM .1516 CFM Fan motor kW 0.00 kW Actual max CFMMt 1.04 CFM/ft Fan static 0.00 in wg Outdoor Ventilation Air Data Design airflow CFM ..... ........ _ 0 CFM CFM/person 0.00 CFM/person CFNVft . 0.00 CFM/fr Hourly Analysis Program v.4.3 Page 1 of 1 Project Name: Escape Outdoor ,Prepared by: Air System Design Load Summary for Retail 12/03/2007 03:12PM ZONE LOADS Window & Skylight Solar Loads Wail Transmission Roof Transmission Window Transmission Skylight Transmission Door Loads Floor Transmission Partitions Ceiling Overhead Lighting Task Lighting Electric Equipment People Infiltration Miscellaneous Safety Factor Total Zone Loads °i: Zone Conditioning P lenum Wall Load Plenum Roof Load Plenum Lighting Load Return Fan Load Ventilation Load Supply Fan Load Space Fan Coil Fans Duct Heat Gain / Loss • :TotarAystem toads Central Cooling Coil Central Heating Coll Toth! Condrtioni Key DESIGN. COOLING': ' DESIGN HEATI AcIPLING DATA AT Jar{2100 • DUNG OA DB /.WB - 58:2;' 150.4 • H TWG DATAAT:Paq HEATING OA-D13 r;WB 23 0'F 1.:19.2'F • 0 ft 0 ft 0 ft 0 ft 0 ft 0 ft Oft= 0 ft Oft' 2228 W 0W 1 000 W 33 30%130% 0% 0% 0% 1541 CFM 0 CFM 1541 CFM 0% bb . fir) 0 0 0 0 0 0 0 0 0 7600 0 3412 10395 0 0 6422 28768 0 0 0 0 0 0 0 0 :28768 28768 0 28768 .Latent (BTU/hr) ' • .•Details 0 ftz 0 ft 0 f 0 ft Oft' • O ft oft' Oft' 0 ft 0 0 0 10725 0 0 0 3218 30% 13943 13943 0 0 0 1541 CFM 0 O CFM 1541 CFM 13944 13944 e risible:; Bll/tit 0 0 0 . 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ent 0 0 0 0 0 0 0 1 0 0 0 ,,: Positive values are Clg loads `:Negative values :ara htg loads Positive halt stare htg; loads' Negative values are.cfg;loads Hourly Analysis Program v.4.3 Page 1 of 1 :r.xi.j4 •° >:',_'TAt31:E'1.1A COMPQNF_tgis Os.,forkUACE,• QNrit 'l1e'1.. ' .:f; ::TABLE.1.1.B. ENVELOPELQAD$PO1'SPACE Retail 4147,o• .7.one1.• s a n t .. :: • .;� .. ';,�•;, ,,:.:•:� . ... •: • •,: ,.• .. r g - •;.Y'�•�?�'�, : 1t�EStGN ; : x ; <; +' : :'�.:`' . , '� .. r COOUNG'DATAAT Jan 2 300 . , } COOL. H+ IO. OADB /:iiVB. S4;9Fa.�6.�'F�:�� OCCUPIED T-STAT 7 - TI NG D ATA , AT `D BI WB : 23b,' H TIN A OCCUPIED . DES �`l Q . ;1'2 'FM1 . :. ._;�_ ,; . .. . ... Vi i... /i.c. F ::i ` `S ' ;'F' ,. - .` :'LL Sensible Sha `:TifANS • '.Latent { , L ' t ti SPACE LOADS' ' ..,, - L�:�::- ry::�� a ..... Details . '•.�BTU/h� .. . � OM/WI v'4: < .f.. ils r... �r ,..- �,Deta� s s @fil/(hrdt TLJ - (B . fill ;'� °':: Tll /hr ' � , Window & Skylight Solar Loads 0 ft (3 - 0 ft Wall Transmission 0 ft 0 - 0 ft 01 - Roof Transmission O ft* 0 - 0 ft 0 - Window Transmission 0 ft 0 - 0 ft 0 - Skylight Transmission 0 ft 0 - 0 ft 0 - Door Loads 0 W 0 - 0 ft 0 - Floor Transmission 0 ft 0 - 0 ft 0 - Partitions 0 ft 0 - 0 ft 0 - Ceiling 0 ft 0 - 0 ft 0 - Overhead lighting 2228 W 7600 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 1000 W 3412 - 0 0 - People 33 10395 10725 0 0 0 Infiltration • - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 30% / 30% 6422 3218 30% 0 0 .,; : ' ' ' » oad :=" : ToWiZone.l -,._ s: . .. . .:..,. - �::``�r � ... X3943: `'''' r yi =`.r _.... r- .. ,..} :,. :.. 0: . ..... "..0 ;: _ .:f; ::TABLE.1.1.B. ENVELOPELQAD$PO1'SPACE Retail 4147,o• .7.one1.• s a n t .. :: • a- , .... . ... •: • •,: ,.• .. .:44r. <= � CO1CftL1N10 - •4001a1VG 1J TING Vi i... /i.c. F ::i ` rJ :'LL slue Sha `:TifANS : TRANS l(BTU/hr) , : -. it °= r°- `: s @fil/(hrdt Coeff. BTU/hr ( Project Name: Escape Outdoor Prepared by: Space Design Load Summary for Retail 12/03/2007 03 :12PM Hourly Analysis Program v.4.3 Page 1 of 1 ,PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL07 - 780 DATE: 12 -13 -07 PROJECT NAME: ESCAPE OUTDOORS SITE ADDRESS: 817 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: L Building Msion Public Works Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 Incomplete ❑ TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: Planning Division C ❑ Permit Coordinator ❑ DUE DATE: 12-18-07 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: n DUE DATE: 01-15-08 Approved ❑ Approved with Conditions M Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License HMELEI *077KR Licensee Name H & M ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 601461695 Ind. Ins. Account Id PRESIDENT Business Type CORPORATION Address 1 918 CEDAR Address 2 City MARYSVILLE County SNOHOMISH State WA Zip 98270 Phone 3606580501 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 5/19/1993 Expiration Date 5/19/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License MCCANJF077LF Business Owner Information Name Role Effective Date Expiration Date CHMELIK, SITKIN & DAVIS PS AGENT 04 /19/2001 MCCANN, KENNETH F PRESIDENT 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Electrical Administrator Information License Name Status MCCANJF077LF MCCANN, JOSEPH F ACTIVE https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= HMELEI *077KR 05/07/2008 RACEWAY STUB —OUT WITH BUSHING HOME RUN TO PANEL OR LOCATION NOTED --- • CIRCUIT CONTINUATION Q /1-Q JUNCTION BOX, CEILING /WALL DUPLEX RECEPTACLE 120V MW = MICROWAVE POS = POINT OF SALE TL — TWIST LOCK DOUBLE DUPLEX RECEPTACLE 120V DUPLEX RECEPTACLE — GROUND FAULT CIRCUIT INTERRUPTER TYPE DEDICATED 20 AMP DUPLEX RECEPTACLE SPLIT SWITCHED DUPLEX RECEPTACLE SPLIT SWITCHED DOUBLE DUPLEX RECEPTACLE DUPLEX RECEPTACLE — ABOVE COUNTER: MOUNT +6" ABOVE COUNTER /SINK/ BACKSPLASH OR MOUNT +54" AFF AS APPLICABLE GFI DUPLEX RECEPTACLE -- ABOVE COUNTER: MOUNT +6" ABOVE COUNTER /SINK/ BACKSPLASH OR MOUNT +54" AFF AS APPLICABLE FLUSH FLOOR BOX WITH DEVICE AS INDICATED t r — i r- .__ - /1/ xxx NEW WIRING. HASH MARKS INDICATE NUMBER OF #12 AWG WIRE UNLESS NOTED OTHERWISE, NO HASH MARKS INDICATES TWO WIRES PLUS GROUND UNLESS NOTED OTHERWISE. LONG HASH MARKS DENOTES NEUTRAL. INDICATES GROUND WIRE. INDICATES ISOLATED GROUND WIRE, WHERE SHOWN. NEW WIRING RUN IN OR BELOW SLAB OR BELOW GRADE. EXISTING RACEWAY OR WIRING (IF HASH MARKS ARE SHOWN PULL NEW CONDUCTORS) — OVERHEAD POWER FROM SERVICE PROVIDER PEDESTAL —STYLE MOUNTED FLOORBOX WITH DEVICE AS INDICATED FLUSH MOUNTED CEILING RECEPTACLE SPECIAL RECEPTACLE, NEMA /VOLTAGE AS INDICATED ON SCHEDULE OR PLAN SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED ON SCHEDULE OR PLAN ON DROP CORD FROM CEILING D DISCONNECT SWITCH ®' FUSED DISCONNECT ®' COMBINATION MOTOR STARTER, DISCONNECT XY MOTOR, SINGLE PHASE EQUIPMENT CONNECTION MOTOR RATED SWITCH PANEL — 208/120 VOLT SYSTEM, +6' TO TOP U.N.O. t M PANEL — 480 VOLT SYSTEM, +6' TO TOP U.N.O. WEATHERHEAD FOR INCOMING POWER FROM SERVICE PROVIDER to PANEL {III WALL — MOUNTED METER FROM SERVICE PROVIDER CIRCUIT BREAKER GROUND PANEL TRANSFORMER 1 AVAILABLE SHORT CIRCUIT CURRENT METER xx — M — EY.Y CIRCUITING SYMBOLS POWER SYMBOLS RISER SYMBOLS MISCELLANEOUS Q FLAG NOTE REVISION SYMBOL EXISTING EQUIPMENT OR DEVICE REMOVE EXISTING ELECTRICAL EQUIPMENT MECHANICAL EQUIPMENT IDENTIFIER KITCHEN EQUIPMENT IDENTIFER, REFERENCE KITCHEN EQUIPMENT SCHEDULE TYPICAL ROOM DETAIL REFERENCES: INDICATES DETAIL NUMBER INDICATES THAT DETAIL IS MIRROR IMAGE OF REFERENCED LOCATION INDICATES SHEET WHERE DETAIL IS FOUND DIRECTION OF ARROW INDICATES PLAN ORIENTATION IN RELATION TO DETAIL SYMBOLS & ABBREVIATIONS xx NL 1 1 NL LIGHTING SYMBOLS FLUORESCENT FIXTURE, TYPE AS INDICATED ON PLAN "XX" INDICATES FIXTURE TYPE, "NL" INDICATES 24HR NIGHTLIGHT OPERATION FLUORESCENT STRIP FIXTURE, DRAWN TO SCALE FIXTURE CEILING MOUNTED FIXTURE WALL MOUNTED SHADED FIXTURES SHALL HAVE INTEGRAL BATTERY BALLASTS "NL" INDICATES 24HR NIGHTLIGHT OPERATION BATTERY PACK EMERGENCY LIGHTING UNIT BATTERY POWERED EXIT SIGN — ARROWS-AS INDICATED, SHADING INDICATES SIDE(S) ILLUMINATED. BATTERY POWERED EXIT SIGN WITH INTEGRAL EMERGENCY LIGHTS, ARROWS AS INDICATED SINGLE POLE SWITCH (LEI ILR INDICATES SWITCH LEG) OCCUPANCY SENSOR WALL SWITCH 3 WAY SWITCH INCANDESCENT DIMMER /SWITCH FLUORESCENT DIMMER /SWITCH NIGHT SETBACK # INDICATES CONTROL ZONE PHOTO —CELL SWITCH MOUNTED UNDER SOFFIT, ORIENT NORTH 11MECLOCK FIXTURE PENDANT MOUNTED SIGNAL & COMMUNICATION SYMBOLS W ® TELEPHONE OUTLET: "W" INDICATES WALL PHONE AT +54" I> DATA OUTLET B COMBINATION TELE /DATA OUTLET -I> COMBINATION TEL /DATA /CABLE TV COMMUNICATION OUTLET 1T = DENOTES No. OF TEL JACKS 1D = DENOTES No. OF DATA JACKS 1C = DENOTES No. OF CABLE TV JACKS THESE EXAMPLES 1 (ONE) JACK EACH D TELEPHONE SERVICE BOX CEILING MOUNTED SPEAKER MOTION DETECTOR SECURITY ALARM KEYPAD DOOR CONTACT FLUSH ENTRY DOOR PUSHBUTTON OPERATOR DOOR CHIME c/w TRANSFORMER CABLE TELEVISION SERVICE BOX ABBREVIATIONS AC INDICATES ABOVE COUNTER MOUNTING AT +4" ABOVE BACKSPLASH OR +6" ABOVE COUNTERS WITHOUT BACKSPLASH AFF ABOVE FINISHED FLOOR A, AMP AMPERE AWG AMERICAN WIRE GAGE CB CIRCUIT BREAKER CKT CIRCUIT c/w COMPLETE WITH DED DEDICATED DW DISHWASHER (E) EXISTING EWC ELECTRIC WATER COOLER FA FIRE ALARM FBOIC FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR G, GND GROUND GFI, GFCI GROUND FAULT CIRCUIT INTERRUPTER HT HEIGHT HWT HOT WATER TANK IH INSTA HOT J —BOX JUNCTION BOX MW N P PNL (R) RO RECPT REF SWBD TELE TYP UC UNO V W 0 W/0 WP MICROWAVE — COORDINATE MOUNTING HEIGHT NEUTRAL POLE PANEL RELOCATED (INDICATES EXISTING EQUIPMENT TO BE RE— INSTALLED AS SHOWN) RACEWAY ONLY RECEPTACLE REFRIGERATOR SWITCHBOARD TELEPHONE TYPICAL UNDERCABINET UNLESS NOTED OTHERWISE VOLT WIRE OR WATT PHASE WITHOUT WEATHERPROOF DRAWING INDEX E0.0 — SYMBOLS & ABBRIEVIATIONS SHEET E0.1 — LIGHTING SCHEDULES & DETAIL SHEET E2.0 — POWER PLAN E3.0 — LIGHTING PLAN E4.0 — ONE —LINE RISER DIAGRAMS & PANEL SCHEDULES SITE KEY PLAN SCALE: NONE „ ee p .m of two o•1 . NOTE: Revisions v, :`s1 .e iu:r ant. plan a eflittat 1 and may :rclude additional plan review lees. i :3Li-ARATE PERMIT , EQUll sED FOR: LMectianlcal ❑ Electrical 1 i Plumbing Gas Piping City of Tukwila 1BUILQIr9G DIVISION LOCATION OF WORK AREA App FILE COPY REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC JAN - 7 2UU8 JAN - 7 2U08 City Of Tukwila BUILDING DIVISION City Of TLa ila BUILDING DIVISION FILE COPY P it I Oo - 1 Plan review a ppraNal Is aslre 4ect entire and omis� �Y8 -' � does not the v o I o f adopted Cede C nance, Rec of = ... .. F>��: • Copy and Is w C City of Tukwila BUILDING DIVISION APPROVED PI "N. "_ AMA r��r -c CATiO c���1 t h' ^T ^T :'ANCED, MODIFIED OR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING on-rAL., ALl WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND IS "3,2c "T TO FIELD INSPECTIONS Public Works, Building division PERMIT NUMBER 07;7 TA RECEIVED CITY OF TUK ILA DEC 13 2007 Ptt�tvtt i (;tNN! I ER ai m z 0 F- 0 or) z 0 0 0 LL, 0 z 1 w CO w 0_ DOLLUDA AINCHITECTS 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206 -624 -4222 f: 206 -624 -4226 ELECTRIC, INC. Drawn Checked Date CLIENTS! OWNER URBAN TRADING 170 BELLEVUE SQUARE BELLEVUE, WA 98004 CONSULTANTS P.O. Box 799 918 Cedar Street Marysville, WA 98270 Office (360) 658 -0501 Fax (360) 658 -0502 www.hmelec.com DESIGN TEAM BrN Engineering, Inc. Electrical Consulting Engineering 2101 9th Avenue, Suite 215 tel: (206)223 -6446 Seattle, Washington 98121 fax: (206)223-6465 Design AO /BB AO BB 12/14/07 REVISIONS No. Date Description INSURANCE TITLE PERMIT SUBMITTAL PROJECT TITLE ESCAPE OUTDOORS AT SOUTHCENTER MALL 633 SOUTHCENTER PARKWAY TU KW I LA, WA 98188 -2886 TEL: 206 -246 -0423 LEVEL 1 AREA 2 TENANT # 1460 DRAWING TITLE SYFVBOLS 8c ABBREVIATIONS SHEET DRAWING NUMBER E0.0 LIGHT FIXTURE SCHEDULE project Address Eecape Outdoors At southcenter Halt Date 12/3/2007 Mowed x Area LAiiP For Building Department Use 1.5 Tukwila WA 98188.2886 TYPE IAAtiUFACTURER SERIES NO. (CATALOG NO.) vOL'tti . TYPE BALLAST FiXTUiI WATTS DESCRIPTION INTERIOR LIGHTING 2228.6 ** From Table 15-1 (over) - document all exceptions on form LTG -LPA Totals 3273.7 4727.9 50 300.0 L1 Eurofase TH -G02 120V 1 50W MR16 XFMR 50 Decorator Adjustable Downlight Satin Chrome Finish L2 Eurofase JIVE 14700 120V 4 50W MR16 XFMR 200 Decorator Adjustable Quad Track Downliight Platinum Finish L3 Eurofase DERVISH 12530 120V 3 60W B13 42.0 180 Decorative Pendant Cord Fixture L4 LBL Onyx HS176 120V 1 50W MR16 11 50 Decorative Onyx cord pendant Cylinder Shade, Satin Nickel hardware L5 Lightolier Lithonia Metatux VS Series 2SP Series, GP Series 120V 2 F32T8 Electronic <1O%I1ID 60 Specification grade recessed mounted lensed troffer nominal 2'x4', code guage steel housing, flush steel door with mitered comers, enclosed positive cam action latches, virgin acrylic prismatic .125" lens. MI interior metal surface to be painted white (min 90%) LB Ughtoler Lithonia Halo Calculite 8011 Series Gotham AFV Series, C4018 Series 120/277V 1 F26W TRT Multi -tap Electronic <10%THD 26 Recessed compact fluorescent open downlight with nominal 4" aperature, vertical lamp position, Clear Alzak semi - specular reflector, self flange matte white. Provided with complete housing frame in kit as required. L7 Ughtdier Uthonia Metalux Si Series S Series, SN Gies 120V 1 F25T8 Electronic <10%THD 28 Surface mounted fluorescent strip fixture, 36" nominal length, low profile steel housing with high reflectance baked white enamel finish. Provide with chain hangar unless specified otherwise. Provide with wireguard where noted 18 Ughtalier Lithonla Metalux SN Series S Series, SN Series 120V 1 F32T8 Electronic <10%THD 30 Surface mounted fluorescent ship fbcture, 48' nominal length, low profile steel housing with high reflectance baked white enamel finish. Provide with chain hangar unless specified otherwise. Provide with wireguard where noted L9 Edge Lighting Inline LED Series 120V 1 LED 24V Xfmr 600W 42 Surface mount LED cove lighting. 7' -2' total consisting of (7) 12' sections and (1) 2' section. Provide system complete with all mounting hardware and interconnecting pieces to make one complete linear Light Provide system with 600W Liitran LV Transformer XP Sure -Liter Lithcnia Lightalier CCX Series Quantum Series LA Series 120V 1 LED 5 Universal mount LED exit sign with green letters, faces and arrow indicators as shown on plans. Mite pcI vcrbcnate housing with stencil face. 20 year LED fife. Integral two circuit transfer relay & NiCad battery for emergency operation. XL Sure -Cites Uthonia Ughtoller CC Series Quantum ELM Series E2 Series 120V 2 6W Halogen 11 Surface mount emergency lighting bug eye" pack. White polycarbonate housing with Integral sealed lead calcium battery for standard 2 -hour operation. Integral sell diagnostic test system GENERAL NOTES REPRESENT A DESIGN BASIS ONLY AND CORRESPOND TO THE LISTED MANUFACTURERS SERIES NUMBER. AND /OR FIXTURE COMPONENTS MAY NOT BE REFLECTED iN THIS NUMBER AND CONTRACTOR RESPONSIBLE FOR PROVIDING IN FIXTURE DESORiPTION AND /OR SPECIFICATIONS. SUBSTITUTION OF FIXTURE TYPES WiLL ONLY BE ACCEPTED IF /COMPONENT QUALITY AND DESIGN INTEGRITY ARE SHOWN TO BE EQUAL TO THE DESIGN INTENT. FINAL DISCRETION ALL SUBSTITUTIONS SHALL INCLUDE PHOTOMETRICS AND BE RECEIVED (5) BUSINESS DAYS PRIOR TO 1. AIL INDICATE) CATALOG NUMBERS ALL OPTIONS, ACCESSORIES ALL SUCH ITEMS DISCLOSED PHOTOMETRICS, CONSTRUCTION TO BE DETERMINED BY ENGINEER. CLOSING FOR ENGINEERING ANALYSIS Project into project Address Eecape Outdoors At southcenter Halt Date 12/3/2007 Mowed x Area 1450 Southcenter Parkway For Building Department Use 1.5 Tukwila WA 98188.2886 Applicant Name: BrN Engineering, inc Applicant Address: 2101 9th Ave Suite 215 - Seattle, WA 98121 Applicant Phone: (205) 223 4448 Location (floor /room no.) Occupancy Description Mowed Watts per ft2 ** Area in ft2 Mowed x Area Marl Floor Rotaail 1.5 1422.7 2134,1 Main Floor Office 1.0 365.3 365.3 liMaiin Floor Additional Retail Allowance (per WSEC 15 fnll;10) 1.50 1485.7 2228.6 ** From Table 15-1 (over) - document all exceptions on form LTG -LPA Totals 3273.7 4727.9 Location (floor/room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed L1 Adjustable Dowrgght - 1L SOW NUM 8 50 400.0 L2 Adjustable Quad Downlight - 4L 'SOW 11818 8 200 1600.0 L3 Hanging Pendant - X. 60W 3 180 540.0 L4 Hanging Pendant - IL SOW 8 50 300.0 L5 2X4 recess prlamega 2L -F32T8 5 60 300.0 La Compact Fluor Downitght - 26W TRT 1 26 26.0 Li 3 Fluor Strip IL-FP-FPS 4 28 112.0 Ls 4'-O' Fluor Strp 1L -F32T8 2 30 60.0 L9 LED strap Cove lighting 1 42 42.0 XP White Pobicarbonate Exit Sign 2 5 10.0 XL Surface mount enure °Bug Eye" Wall pack 2 11 22.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 3412.0 Lighting Summary Note new automatic daylighting. occupancy sensor. and other control requirements of Section 1513. CIS applicable. Project Description 0 New Building ❑ Addition Alteration 11 Bldg. >5,000 sq.ft. (auto shutoff req Indicate controls (SEC Section 1513) including commissioning requirements on plans. 0 Plans Included Compliance Option Prescriptive Lighting Power Allowance Systems Analysis Alteration Exceptions (check appropriate box) 9 No changes are being made to the lighting II<60% of fixtures new, installed lighitng wattage is not increased, and Table 15-1 use is not changed Maximum Allowed Lighting Wattage (Interior) Proposed Lighting Wattage (rot.) Notes on Proposed Lighting Wattage: 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. 2. Include exit lights exceeding 5.0 watts per fixture. 3. List all fixtures. For exempt lighting, note exception on applicable fixtures. LTG -SUM TO LIGHTING CIRCUITS FLAG NOTES: PROVIDE 1- CHANNEL TIMECLOCK 24 HOUR/7- DAY /HOLIDAY, PROGRAMMABLE TiMECLOCK WITH BA I I ERY BACKUP, COMPLIANT WITH WASHINGTON STATE ENERGY CODE REQUIREMENTS. PARAGON EL71D /185 OR EQUAL COORDINATE PROPER INPUT VOLTAGE. STOREFRONT SIGNAGE AND LIGHTING TiMECLOCK SHALL BE SET TO MALL'S OPERATING HOURS. LIGHTING CONTACTOR LOCATED IN ACCESSIBLE CEILING SPACE PROVIDE SUITABLE NIGHT SETBACK CONTROL WITH FLICKER WARNING FUNCTION TO PROVIDE UP TO 2 -HOUR OPERATION. PARAGON ET1100F OR EQUAL OFF PANEL B2 13 15 = 17 ---� 19 SCALE: NONE AUTO 0 0 HAND HOA SWITCH m m MULTi -HEAD TRACK LIGHTS STORE PENDANTS PRIVA UTE GLASS DISPLAY BACK OF HOUSE SPARE SPARE LIGHTING CONTROL DETAIL RED IEWMP�NCE C ®DE CO NFPA 70 a NEC JAN - 7 Nti SIGN Cetygf Tu" .11 a g L�11)5 D LO77° RECEIVED CITY OF TUKWILA DEC 1 3 2007 i- iGnivu a L ;;I\I I tR CD tcr C� z 0 H C H U) z 0 O LL H O z I lopIoLLuDA AINCHITECTS ELECTRIC, INC. Design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206 -624 -4222 f: 206 -624 -4226 CLIENTS/ OWNER URBAN TRADING 170 BELLEVUE SQUARE BELLEVUE, WA 98004 CONSULTANTS P.O. Box 799 918 Cedar Street Marysville, WA 98270 Office (360) 658 -0501 Fax (360) 658 -0502 www.hmelec.com DESIGN TEAM BrN Engineering, Inc. Electrical Consulting Engineering 2101 9th Avenue, Suite 215 tel: (206)223 -6446 Seattle, Washington 98121 fax: (206)223 -6465 AO /BB Drawn Checked Date AO BB 12/14/07 EXPIRES 1/17/ . : REVISIONS No. Date Description INSURANCE TITLE PERMIT SUBMITTAL PROJECT TITLE ESCAPE OUTDOORS AT SOUTHCENTER MALL 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188 -2886 TEL: 206- 246 -0423 LEVEL 1 AREA 2 TENANT # 1460 DRAWING TITLE LIGHTING SCHEDULES &c DETAIL SHEET DRAWING NUMBER E0.1 PROJECTOR POWER SUPPLY LOCATION OF PRIVA GLASS POWER SUPPLY (SEE E3.0) SECURITY 8,10,12,14 013 10 0 ' 3 10 F� (1) 1" RACEWAY FOR POWER (1) 1" RACEWAY FOR LOW VOLTAGE IN SLAB POWER PLAN SCALE 1/4" = 1' -0" 0i3 B2 -16,18 B2 -2,4,6 14 14 B2— x,10,12,14 COFFEE J 'MICROWA I L FPT -1 +3' -6 "AFF A4 -1 \ B2 -1,3, 5,7,9 PANEL B2 FAN IN CEILING #10 A4 -3 .11 \ \� \\ 1!1' 11 U FPT -2 I FIRESEAL 6 TRANSFORMER PANEL A4 RELOCATED EXISTING FUSD DISCONNECT SWITCH(PROVIDED BY LAN LORD) TELEPHONE SERVICE BACKBOARD GENERAL NOTES: 1 FIRE ALARM SYSTEM DESIGN, SHOP DRAWINGS PLAN, AND REVIEW PERMIT TESTING BY OTHERS: GUARDIAN SECURITY. 2. CONTRACTOR MUST PREDRILL AND USE ANCHORS FOR ANY ATTACHMENT OF ANCHORS, HANGARS AND EQUIPMENT TO THE DECK STRUCTURE ABOVE. WHEREVER POSSIBLE ALL ATTACHMENTS SHOULD BE MADE TO THE STRUCTURAL BEAMS. DIRECT POWER SHOOTING OF ANCHORS OR ATTACHMENTS TO THE DECK WILL NOT BE ALLOWED. FLAG NOTES: STUB RACEWAYS INTO CABINET BASE. PROVIDE 4 —GANG HOUSING PEDESTAL —STYLE BOX WITH BLANK COVER PLATE ON BACK AND WITH APPROPRIATE COVER ON FRONT FOR BOTH THE POWER AND DATA DEVICES. HUBBELL SA6688 OR EQUAL TO LANDLORD TELEPHONE VIA LANDLORD CABLE TRAY. PROVIDE DOOR BELL IN ACCORDANCE WITH LANDLORD REQUIREMENT. ��. E XCW NCB CODE COMPLIANCE NrC NRA AO -1 ` CO Of Uonila EL07-'1g RECEIVED CITY OF TUKzNILA DEC 13 2007 PLntvtt s (,tl' I ER lOPIOLLUDA A1NCHITECTS t: 206 -624 -4222 f: 206- 624 -4226 CLIENTS/ OWNER ELECTRIC, INC. DESIGN TEAM 105 S. Main Street Suite 323 Seattle, WA 98104 URBAN TRADING 170 BELLEVUE SQUARE BELLEVUE, WA 98004 Design Drawn CONSULTANTS P.O. Box 799 918 Cedar Street Marysville, WA 98270 Office (360) 658 -0501 Fax (360) 658 -0502 www.hmelec.com BrN Engineering, Inc. Electrical Consulting Engineering 2101 9th Avenue, Suite 215 tel: (206)223 -6446 Seattle, Washington 98121 fax: (206)223-6465 AO /BB AO Checked BB Date 12/14/07 RE IM11 /17/ REVISIONS No. Date Description INSURANCE TITLE PERMIT SUBMITTAL PROJECT TITLE ESCAPE OUTDOORS AT SOUTHCENTER MALL 633 SOUTHCENTER PARKWAY TU KW I LA, WA 98188 -2886 TEL: 206 - 246 -0423 LEVEL 1 AREA 2 TENANT # 1460 DRAWING TITLE POWER PLAN DRAWING NUMBER E2.0 PRIVA LITE GLASS CONNECTIO 5c 15d 1 ^,4 j,4 f5c \ L4 LED. STRIP POWER SUPPLY PRIVA LITE POWER SUPPLY � n 13a 0 L2 XP 16" X 1 SHELF 4 _. n n 13a U V L2 0 1 /vim o fiDDU /,DF AVF/L/i-- / A /.-4 ,1/4 i4JA -T /a - cC 13a ' U U 1L2 • 1 3a = L2 'A 5�c � 1 ° -t1 •15b L3 XL (4) 3' — FLUORESCENT STRIP FIXTURES MOUNTED HORIZONTALLY BEHIND SIGN (TV.) i 8 130 O 0 . . - L 2 - o o 130 15c 15c 15c - L4 L4 L4 0 TYPICAL 15c 15c1 L8 L? _15c LZ LS I 4' —O" FLUORESCENT STRIP FIXTURE MOUNTED VERTICALLY BEHIND SIGN (1W.) XL � 13a • ao L2 0 0 13a V L2 LIGHTING PLAIo! O SCALE: 1/4" = r —o SCALE: 1 /4" = 1' -0" U B2- 13.15,17.19 ' CO\ GENERAL NOTES: 1. CONTRACTOR MUST PREDRILL AND USE ANCHORS FOR ANY ATTACHMENT OF ANCHORS, HANGARS AND EQUIPMENT TO THE DECK STRUCTURE ABOVE. WHEREVER POSSIBLE ALL ATTACHMENTS SHOULD BE MADE TO THE STRUCTURAL BEAMS. DIRECT POWER SHOOTING OF ANCHORS OR ATTACHMENTS TO THE DECK WILL NOT BE ALLOWED. FLAG NOTES: POWER SUPPLY /CONTROL RELAY AND LED STRIP POWER SUPPLY LOCATED ON SHELF INSIDE OF ENTRANCE PORTAL SHELF PROVIDED WITH ACCESS PANEL SEE ARCHITECTURAL PLANS FOR DETAILS. ROUTE PRIVA LITE CABLES CONCEALED IN STORE FRONT MULLION. SEE ARCHITECTURAL DETAIL 1/A2.02. COORDINATE SPEAKERS WITH FIRE ALARM VENDOR. i-p Cl � OF T�UKt fILA DEC 13 2007 I'tl�lvli i (.;tN I ER z 0 F- F- z 0 0 0 F- 0 z F— r w U) F- w 0 DOLLUDA AlkCHITECTS CLIENTS/ OWNER 170 BELLEVUE SQUARE BELLEVUE, WA 98004 ELECTRIC, INC. DESIGN TEAM Design Drawn Checked Date 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206 -624 -4222 f: 206 - 624 -4226 URBAN TRADING CONSULTANTS P.Q. Box 799 918 Cedar Street Marysville, WA 98270 Office (360) 658 -0501 Fax (360) 658 -0502 www.hmelec.com BrN Engineering, Inc. Electrical Consulting Engineering 2101 9th Avenue, Suite 215 tel: (206)223 -6446 Seattle, Washington 98121 fax: (206)223 -6465 AO/BB AO BB 12/14/07 LI TRES 1 /17 /za- I ASITIONMOMMIIIIEL REVISIONS No. Date Description INSURANCE TITLE PERMIT SUBMITTAL PROJECT TITLE ESCAPE OUTDOORS AT SOUTHCENTER MALL 633 SOUTHCENTER PARKWAY TU KW I LA, WA 98188 -2886 TEL: 206- 246 -0423 LEVEL 1 AREA 2 TENANT # 1460 DRAWING TITLE LIGHTING PLAN DRAWING NUMBER E3.0 GENERAL NOTES: 1. EXISTING LOADS ON MAIN DISTRIBUTION PANEL (MDP) HAVE NOT BEEN VERIFIED. IT IS ASSUMED THAT THE LANDLORD AND TENANT HAVE AN AGREEMENT THAT THE MDP HALL HAVE SUFFICIENT CAPACITY TO ACCOMODATE LOAD REQUIREMENTS FOR THE NEW TENANT PANEL TENANT DISCONNECT TO UTILITY 2. RISER DIAGRAM IS NOT REPRE TA11VE OF ACTUAL SWITCHBOARD LAYOUT. FIELD VERIFY ELECTRICAL ROOM FOR PHYSICAL LAYOUT WITH RESPECT TO ACTUAL MANUFACTURED AND INSTALLED CONDITIONS. 3. ALL TENANT BRANCH WIRING TO BE COPPER WITH TYPE TW, THW, THWN OR THHN INSULATION AND BE MINIMUM #12 AWG UNLESS NOTED OTHERWISE 4. NO BX, AC, OR ROMEX TYPE WIRING ALLOWED. 5. INSTALL TYPEWRITTEN PANEL L-..EDULES IN ALL TENANT PANELS INDICATING FINAL AS -BUILT CONDITIONS. FLAG NOTES: PROVIDE CONDUIT /CONDUCTORS AS REQUIRED TO NEW TENANT PANEL FROM LANDLORD DISTRIBUTION. PROVIDE LABEUNG AT LANDLORD SWITCHBOARD IN ACCORDANCE WITH LANDLORD REQUIRMENTS. 2 "C,4#3/0,1 #4 GND PANEL A4 FBOIC 200/3 2"C,4#3/0,1#4 GND L EXISTING COMMERCIAL METER STACK 200/3 SCALE: NONE 4 ESCAPE OUTDOORS TENANT SPACE (E) MAIN DISTRIBUTION SWITCHBOARD 30KVA 480: 208Y/120V 30, 4W 3/4 "C, 3#6, #10G = r e G #3/0 CU PANEL B2 100A MCB J POWER ONE -LINE DIAGRAM -TC 1 1/4"C,4-#1, #6G EXISTING BUILDING GROUND CONDFP COMPLIANCE NEC )gl - 7 r uti rite Of Tukwila EL.cn-w s 0 OLLUDA A1NCHITECTS 170 BELLEVUE SQUARE BELLEVUE, WA 98004 ELECTRIC, INC. DESIGN TEAM Design AO /BB Drawn AO Checked Date 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206- 624 -4222 f: 206- 624 -4226 CLIENTS/ OWNER URBAN TRADING CONSULTANTS P.O. Box 799 918 Cedar Street Marysville, WA 98270 Office (360) 658 -0501 Fax (360) 658 -0502 www.hmelec.com BrN Engineering, Inc. Electrical Consulting Engineering 2101 9th Avenue, Suite 215 tel: (206)223 -6446 Seattle, Washington 98121 fax: (206)223 -6465 BB 12/14/07 1D P RES 1/17/ . ow REVISIONS No. Date Description INSURANCE TITLE PERMIT SUBMITTAL PROJECT TITLE ESCAPE OUTDOORS AT SOUTHCENTER MALL 633 SOUTHCENTER PARKWAY TU KW I LA, WA 98188 -2886 TEL: 206 -246 -0423 LEVEL 1 AREA 2 TENANT # 1460 DRAWING TITLE ONE -LINE RISER DIAGRAMS & PANEL SCHEDULES DRAWING NUMBER E4.0 PERMIT SET - NOT FOR CONSTRUCTION - 12/14/07 OI Iti niNG DIVIV-V-D---' PANEL SCHEDULE PANEL: B2 LOCATION: Tenant Space Tenant Space VOLTS: 208 Y/ 120 P 3 W: 4 AIC RATING: 10,000 MOUNT: X SURFACE FLUSH NEUTRAL: 100% FED FROM PANEL A4 (via 30kva Xfmr) AMP: 100 MLO NICE X AMP: 200 MLO X MCB D TYPE: EXISTING NEW X STYLE: TYPE: EXISTING NEW X STYLE: CIRCUIT DESCRIPTION LOAD TYPE LOAD KVA CKT BKR CKT BKR P P CIR £ ! O. = CIR £ P CKT BKR LOAD KVA LOAD TYPE CIRCUIT DESCRIPTION REC - STORAGE ROOM REC 0.90 20 30 1 1 1 2 1 20 0.90 REC REC - SOUTH WALL REC - OFFICE 105 REC 0.72 20 15 1 1 3 4 4 1 20 1.20 MISC REC - CASH WRAP BACK REC - OFFICE 106 REC 0.72 20 1 5 5 j 6 1 20 1.20 MISC REC - CASH WRAP BACK COFFEE MISC 1.20 20 20 1 1 7 8 8 1 20 0.36 MISC REC - CEILING MICROWAVE MISC 1.20 20 1 ` 9 ! 10 1 20 0.36 MISC REC - CEILING 20 1 11 11 12 1 20 0.72 MISC SECURITY/PROJECTOR LTG - MULTI HEAD TRACK LIGHTS LTG t60 20 20 1 1 13 ; i � 14 1 20 0.54 REC REC - NORTH WALL LTG - STORE PENDANTS, BACK OF HOUSE LTG 1.30 20 1 15 I 15 16 1 20 1.20 MISC REC - CASH WRAP FRONT 1LTG - PRIVA GLASS DISPLAY LTG 1.00 20 1 17 17 18 1 20 1.20 MISC REC - CASH WRAP FRONT LTG - BACK OF HOUSE LTG 0.40 20 1 19 19 1 20 1 20 I 20 20 1 1 21 22 1 20 I 20 20 1 : 23 j 24 1 20 I I 20 LOAD SUMMARY: LOAD 11101INNECTED E.M.D. CALCULATED 1 25 j 26 1 20 PHASE A: 12.47 KVA PHASE B: 8.31 KVA PHASE C: 4.84 KVA GENERAL NOTES: i 1 NOTES FLAG NOTES: 20 "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD "MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED 1 27 ' I 28 1 20 20 1 29 30 1 20 ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS LOAD SUMMARY: LOAD TIVONNECTED E.M.D. CALCULATED CONNECTED PHASE LOADING LIGHTING LTG 4.30 KVA RESIDENT LTG/RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR 0.00 KVA REMAINING MOTORS MTR 0.00 KVA GEN PURPOSE RECPT REC 3.78 KVA COMPUTER RECPT MISC 4.80 KVA EQUIP /OTHER MISC 3.84 KVA HEATING MISC 0.00 KVA ELEVATOR ELEV 0.00 KVA KITCHEN EQPT KITCH 0.00 KVA TOTALS 16.72 KVA 46.41 AMPS WAD TYPE NOTES: 5.38 KVA (125 %) 0.00 KVA ( 100/35/25 %) 0.00 KVA ( 100/35/25 %) 0.00 KVA (125 %) 0.00 KVA (100 %) 3.78 KVA ( 50% > 1 OKVA) 4.80 KVA (100 %) 3.84 KVA (100 %) 0.00 KVA (100 %) 0.00 KVA CO 100% 0.00 KVA CO 65% 17.80 KVA 49.39 AMPS TAKEN AT INDICATED DEMAND CIRCUIT AT 100% PHASE A: 5.90 KVA PHASE B: 5.98 KVA PHASE C: 4.84 KVA GENERAL NOTES: DEVICE FOR ALL BRAKERS FEEDING FIRE ALARM, SECURITY LIGHTING. RECEIVED CITY OF TUrP;lLA DEC 1 3 2007 1 crlIVII 1 traINI t ER 1 PROVIDE LOCK ON AND /OR EMERGENCY FLAG NOTES: 1 "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES" = RESIDENTIAL LTG /RECPT OR SMALL APPLIANCE LOAD "MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED GENERAL NOTES: 1. EXISTING LOADS ON MAIN DISTRIBUTION PANEL (MDP) HAVE NOT BEEN VERIFIED. IT IS ASSUMED THAT THE LANDLORD AND TENANT HAVE AN AGREEMENT THAT THE MDP HALL HAVE SUFFICIENT CAPACITY TO ACCOMODATE LOAD REQUIREMENTS FOR THE NEW TENANT PANEL TENANT DISCONNECT TO UTILITY 2. RISER DIAGRAM IS NOT REPRE TA11VE OF ACTUAL SWITCHBOARD LAYOUT. FIELD VERIFY ELECTRICAL ROOM FOR PHYSICAL LAYOUT WITH RESPECT TO ACTUAL MANUFACTURED AND INSTALLED CONDITIONS. 3. ALL TENANT BRANCH WIRING TO BE COPPER WITH TYPE TW, THW, THWN OR THHN INSULATION AND BE MINIMUM #12 AWG UNLESS NOTED OTHERWISE 4. NO BX, AC, OR ROMEX TYPE WIRING ALLOWED. 5. INSTALL TYPEWRITTEN PANEL L-..EDULES IN ALL TENANT PANELS INDICATING FINAL AS -BUILT CONDITIONS. FLAG NOTES: PROVIDE CONDUIT /CONDUCTORS AS REQUIRED TO NEW TENANT PANEL FROM LANDLORD DISTRIBUTION. PROVIDE LABEUNG AT LANDLORD SWITCHBOARD IN ACCORDANCE WITH LANDLORD REQUIRMENTS. 2 "C,4#3/0,1 #4 GND PANEL A4 FBOIC 200/3 2"C,4#3/0,1#4 GND L EXISTING COMMERCIAL METER STACK 200/3 SCALE: NONE 4 ESCAPE OUTDOORS TENANT SPACE (E) MAIN DISTRIBUTION SWITCHBOARD 30KVA 480: 208Y/120V 30, 4W 3/4 "C, 3#6, #10G = r e G #3/0 CU PANEL B2 100A MCB J POWER ONE -LINE DIAGRAM -TC 1 1/4"C,4-#1, #6G EXISTING BUILDING GROUND CONDFP COMPLIANCE NEC )gl - 7 r uti rite Of Tukwila EL.cn-w s 0 OLLUDA A1NCHITECTS 170 BELLEVUE SQUARE BELLEVUE, WA 98004 ELECTRIC, INC. DESIGN TEAM Design AO /BB Drawn AO Checked Date 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206- 624 -4222 f: 206- 624 -4226 CLIENTS/ OWNER URBAN TRADING CONSULTANTS P.O. Box 799 918 Cedar Street Marysville, WA 98270 Office (360) 658 -0501 Fax (360) 658 -0502 www.hmelec.com BrN Engineering, Inc. Electrical Consulting Engineering 2101 9th Avenue, Suite 215 tel: (206)223 -6446 Seattle, Washington 98121 fax: (206)223 -6465 BB 12/14/07 1D P RES 1/17/ . ow REVISIONS No. Date Description INSURANCE TITLE PERMIT SUBMITTAL PROJECT TITLE ESCAPE OUTDOORS AT SOUTHCENTER MALL 633 SOUTHCENTER PARKWAY TU KW I LA, WA 98188 -2886 TEL: 206 -246 -0423 LEVEL 1 AREA 2 TENANT # 1460 DRAWING TITLE ONE -LINE RISER DIAGRAMS & PANEL SCHEDULES DRAWING NUMBER E4.0 PERMIT SET - NOT FOR CONSTRUCTION - 12/14/07 PANEL SCHEDULE PANEL: A4 LOCATION: Tenant Space VOLTS: 480 Y/ 277 P 3 W: 4 AIC RATING: 14,000 MOUNT: X SURFACE NEUTRAL 100% FED FROM: MALL DISTRIBUTION FLUSH AMP: 200 MLO X MCB D TYPE: EXISTING NEW X STYLE: CIRCUIT DESCRIPTION LOAD TYPE LOAD KVA CKT BKR P CM 2 II CIR £ P CKT BKR LOAD KVA LOAD TYPE CIRCUIT DESCRIPTION FPT -1 (5KW HEAT, 3 /4HP, FAN) COMB 6.57 30 1 1 j 2 3 50 5.90 COMB PANEL B2 (VIA 30KVA XFMR) FPT -2 (1.5KW HEAT, 1/3HP, FAN) ' COMB 2.33 15 1 3 4 - - 5.98 COMB - 20 1 5 i 1 6 - - 4.84 COMB - 20 1 7 8 1 20 20 1 9 10 1 20 20 1 11 I 12 1 20 20 1 13 j 14 1 20 20 1 15 I 16 1 20 20 1 17 I 18 1 20 1 20 1 19 20 1 20 I 20 1 21 22 1 20 I 20 1 23 24 1 20 I ESTIMATED MAXIMUM DEMAND IEMDI CALCULATIONS LOAD SUMMARY: LOAD 11101INNECTED E.M.D. CALCULATED CONNECTED PHASE LOADING LIGHTING LTG 4.30 KVA RESIDENT LTG /RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR 0.00 KVA REMAINING MOTORS MTR 2.40 KVA GEN PURPOSE RECPT REC 3.78 KVA COMPUTER RECPT MISC 4.80 KVA EQUIP /OTHER MISC 3.84 KVA HEATING MISC 6.50 KVA ELEVATOR ELEV 0.00 KVA KITCHEN EQPT KITCH 0.00 KVA TOTALS 25.62 KVA 30.82 AMPS LOAD TYPE NOTES: 5.38 KVA (125 %) 0.00 KVA ( 100/35/25 %) 0.00 KVA ( 100/35/25 %) 0.00 KVA (125 %) 2.40 KVA (100 %) 3.78 KVA ( 50% > 10KVA) 4.80 KVA (100 %) 3.84 KVA (100 %) 6.50 KVA (100 %) 0.00 KVA © 100% 0.00 KVA Co 65% 26.70 KVA 32.11 AMPS TAKEN AT INDICATED DEMAND CIRCUIT AT 100% PHASE A: 12.47 KVA PHASE B: 8.31 KVA PHASE C: 4.84 KVA GENERAL NOTES: 1 NOTES FLAG NOTES: 1 "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD "MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED GENERAL NOTES: 1. EXISTING LOADS ON MAIN DISTRIBUTION PANEL (MDP) HAVE NOT BEEN VERIFIED. IT IS ASSUMED THAT THE LANDLORD AND TENANT HAVE AN AGREEMENT THAT THE MDP HALL HAVE SUFFICIENT CAPACITY TO ACCOMODATE LOAD REQUIREMENTS FOR THE NEW TENANT PANEL TENANT DISCONNECT TO UTILITY 2. RISER DIAGRAM IS NOT REPRE TA11VE OF ACTUAL SWITCHBOARD LAYOUT. FIELD VERIFY ELECTRICAL ROOM FOR PHYSICAL LAYOUT WITH RESPECT TO ACTUAL MANUFACTURED AND INSTALLED CONDITIONS. 3. ALL TENANT BRANCH WIRING TO BE COPPER WITH TYPE TW, THW, THWN OR THHN INSULATION AND BE MINIMUM #12 AWG UNLESS NOTED OTHERWISE 4. NO BX, AC, OR ROMEX TYPE WIRING ALLOWED. 5. INSTALL TYPEWRITTEN PANEL L-..EDULES IN ALL TENANT PANELS INDICATING FINAL AS -BUILT CONDITIONS. FLAG NOTES: PROVIDE CONDUIT /CONDUCTORS AS REQUIRED TO NEW TENANT PANEL FROM LANDLORD DISTRIBUTION. PROVIDE LABEUNG AT LANDLORD SWITCHBOARD IN ACCORDANCE WITH LANDLORD REQUIRMENTS. 2 "C,4#3/0,1 #4 GND PANEL A4 FBOIC 200/3 2"C,4#3/0,1#4 GND L EXISTING COMMERCIAL METER STACK 200/3 SCALE: NONE 4 ESCAPE OUTDOORS TENANT SPACE (E) MAIN DISTRIBUTION SWITCHBOARD 30KVA 480: 208Y/120V 30, 4W 3/4 "C, 3#6, #10G = r e G #3/0 CU PANEL B2 100A MCB J POWER ONE -LINE DIAGRAM -TC 1 1/4"C,4-#1, #6G EXISTING BUILDING GROUND CONDFP COMPLIANCE NEC )gl - 7 r uti rite Of Tukwila EL.cn-w s 0 OLLUDA A1NCHITECTS 170 BELLEVUE SQUARE BELLEVUE, WA 98004 ELECTRIC, INC. DESIGN TEAM Design AO /BB Drawn AO Checked Date 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206- 624 -4222 f: 206- 624 -4226 CLIENTS/ OWNER URBAN TRADING CONSULTANTS P.O. Box 799 918 Cedar Street Marysville, WA 98270 Office (360) 658 -0501 Fax (360) 658 -0502 www.hmelec.com BrN Engineering, Inc. Electrical Consulting Engineering 2101 9th Avenue, Suite 215 tel: (206)223 -6446 Seattle, Washington 98121 fax: (206)223 -6465 BB 12/14/07 1D P RES 1/17/ . ow REVISIONS No. Date Description INSURANCE TITLE PERMIT SUBMITTAL PROJECT TITLE ESCAPE OUTDOORS AT SOUTHCENTER MALL 633 SOUTHCENTER PARKWAY TU KW I LA, WA 98188 -2886 TEL: 206 -246 -0423 LEVEL 1 AREA 2 TENANT # 1460 DRAWING TITLE ONE -LINE RISER DIAGRAMS & PANEL SCHEDULES DRAWING NUMBER E4.0 PERMIT SET - NOT FOR CONSTRUCTION - 12/14/07