Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL07-791 - WESTFIELD SOUTHCENTER MALL - BARE ESCENTUALS
BARE ESCENTUALS 827 SOUTHCENTER MALL ELO7-79 1 Parcel No.: Address: Suite No: doc: EL -4/07 Tenant: Name: Address: Owner: Name: Address: Chf Tukwila Contact Person: Name: BOB ROBINSON Address: 37936 23 PL S , FEDERAL WAY WA Contractor: Name: BURICE ELECTRIC LLC Address: 13563 SE 27 PL , BELLEVUE WA Contractor License No: BURKEEL022BA Value of Electrical: $31,900.00 Type of Fire Protection: Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 827 SOUTHCENTER MALL TUKW BARE ESCENTUALS 827 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA DESCRIPTION OF WORK: ELECTRICAL WORK FOR TENANT IMPROVEMENT: (1) NEW TRANSFORMER PANEL AND POWER & LIGHTING. Electrical Service provided by: PUGET SOUND ENERGY . th ELECTRICAL PERMIT EL07 -791 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 677 -6874 Phone: 425 644 -0351 Expiration Date: 01/01/2010 Fees Collected: National Electrical Code Edition: EL07 -791 05/12/2008 11/08/2008 Date: F $758.50 2005 ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this peymit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pei!o e of work. I am authorized to sign and obtain this electrical permit. Signature: Date: Print Name: e 67/ ?/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 05-12 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: I: ** *ELECTRICAL * ** Signature: Print Name: doc: Cond -Elec City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 827 SOUTHCENTER MALL TUKW BARE ESCENTUALS 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: Date: 05- 7/ 6 0 7 0 EL07 -791 ISSUED 12/19/2007 05/12/2008 EL07 -791 Printed: 05-12 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www. ci. tkwila. wa. us Electrical Permit No. ft/01 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** I SITE LOCATION 4 Kin Co Assessor's Tax No.: 1/ C Site Address • SOUn'l C - p � 0 � r Suite Number: �'' � Floor: Tenant Name: ...S v 11 tY'W //�� New Tenant: I=1 Yes ❑ ..No Property Owners Name: w ��TF A Cb��T 1 D'v l } � � a �� WI I.-Sii IM Bub, j 1 { F- L tt VR L Cf ' 1 002V Mailing Address: FL/ State Zip CONTACT PERSON — Who do we contact when your permit is ready to be lamed Name: 11' i t 1 Day Telephone: ?S 7 7 S 1 7 -` Mailing Address: ?O Z.-3/4 P' s Feel 149azi r f 0143 n Y City State zip E -Mail Address: /�'1 t+ 5 LP l0 �� ►s7 • no Fax Number: Zs3 `�O�O -�O Of ELECTRICAL CONTRACTOR INFORMATION Will service be altered? ❑ Yes ( $f No Adding more than 50 amps? ❑ Yes 71 No Type of Use: Type of work: 14 New ❑ Addition ❑ Service Change ❑ Remodel Tenant Improvement UYIrN) ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Pro rtv Served bv: Puget Sound Energy ❑ Seattle City Light Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ 3i1 �� Scope of Work (please provide detailed information): C. Y C-ftt-- 4 1 N i 1 N 4 oNe N - s rogm-CK z kV\ L G fiT M G T kNT 1 m rIzw arn mr1 wD H:\Applications\Forms- Applications On Line4-2007 - Electrical Permit Application.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) BUILDING OWNER OR ELECTRICAL CONTRACTOR: Mailing Address: 5713 z P . $ Date Application Accepted: ( t 1 H: Applicationffonns•Applications On Line4-2007 - Electrical Permit Application.doc bh MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. :ecIti v YVal City MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea [ EiMITAPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Signature: Date: k.2/11 1 b Print Name: 1354:2 O .61 tler, P) Day Telephone: 2.5 34077 - 7 state Staff Initials: Zip Date Application Expires: o( I0i Page 2 of 2 Receipt No.: R07 -02803 Payee: TECTA ASSOCIATES TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL07 -791 Address: 827 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 12/19/2007 Applicant: BARE ESCENTUALS Issue Date: Initials: JEM Payment Date: 12/19/2007 10:24 AM User ID: 1165 Balance: $606.80 Amount Payment Check 2676 151.70 Account Code Current Pmts 000.345.832.00.0 151.70 Total: $151.70 Payment Amount: $151.70 6263 12/19 9710 TOTAL 151.70 doc: Receiot -06 Printed: 12 -19 -2007 Receipt No.: R08 -01556 Payee: BURKE ELECTRIC, LLC ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Payment Check 3003 606.80 TRANSACTION LIST: Type Method Descriptio Amount RECEIPT Parcel No.: 6364200010 Permit Number: ELO7 -791 Address: 827 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 12/19/2007 Applicant: BARE ESCENTUALS Issue Date: Initials: JEM Payment Date: 05/12/2008 10:24 AM User ID: 1165 Balance: 60.00 Account Code Current Pmts 000.322.101.00.0 606.80 Total: $606.80 Payment Amount: 6606.80 2268 05/12 9711 TOTAL 606.80 doc: Receipt -06 Printed: 05-12 -2008 Project: Type of Inspection: /0 v Address: .1 Date Called: Special Instructions: Date Wanted: �� a.m. p.m Requester: Phone No: (Inspector: -1;16 INSPECTION RECORD Retain a copy with permit t�� -1 ' INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION w 6300 S ou t h ce nter Blvd. #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. COMMENTS: e ■ 1Date: ( (�1 D). $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: k - �.,._� Project: Type of Inspection: VOO Address: n , IO Date Called: Special Instructions: Date Wanted: 7/(1 ea.L., Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. [] Corrections required prior to approval. COMMENTS: D_K rf/JA-t- 'Inspector: �!�! API( 'Date: in ©o' l� El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 4141#1610411. - t . g ftli ;.' CL-07-791 PERMIT NO. (206)431 -3670 'Receipt No.: 'Date: COMMENTS: T ype o f Ins - 7ToG4. SI71 Address: y ` , p - PtJct,'iI, 4 4k 51 Rite 9 .rn &1 oP Mac L1ctwfoL\ - 5f J & e,....,..7 • 'B�5 l G ty 62- `, PE • KC -- C114 AL p.m. Requester: Project`/ 6� ��/S T ype o f Ins 2,00 Address: y ` , p Date Called: Special Instructions: Date Wanted: ii6 p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit 601-11 I PERMrr NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 63 00 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. !Inspector: 'Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 Receipt No.: 'Date: • Project: bow � s Type of Inspection: 7003 Address: � Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 1 40104 (A (inspector: �� 6 _ _ /� f, !Date: a7 /110 (V' n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. !Receipt No.: 'Date: i!> ^` v ���71i,5. Type of Ins spectior 790 ? A 4P: 7 5 C P L Date Called: Special Instructions: Date Wanted: t, , �) �/ 1 C/ a.m. p.m. Requester: Phone No: [407-7v INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION \it 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 I pproved per applicable codes. Corrections required prior to approval. COMMENTS: e �y< G1lA — GG � Ei� ,(r/1C1� /ZO7 Pita" C��� - /�ES� c M / /se - 146 1)//v4t vuif % 664S /fT 5 Inspector / 2 /,164%MDate: ‘0/494 r $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Project :131a ( 5 c I ,`/ _ �Tri Type of Inspection: 7003 � OO' Address: `i at f V , Date Called: Special Instructions: Date Wanted: .m. �/ 3 p Requester: Phone No: INSPECTION RECORD ' Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Ei Approved per applicable codes. El Corrections required prior to approval. COMMENTS: vJ44.0 I iE,A-ep u5 6iCP,ter 64(4_ Raa1 0.K. — oNoR5 -3 605 G 77O2.-- Inspector: ad 66 r ate 04/ El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project Info Project Address BARE itscilacaug Date 12/14/2007 633 SoDTac PARKWAY For Buildir�Bep SPACE f ED F CODE COMPLI) NFPA 70 - NI - 2 7Iiiif T°KWIL`' 'A Applicant Name: AHemD IIZAB Applicant Address: 2747 19TH STREET, SAN PPANCISOO, ca 94110 Applicant Phone: 415-362-5857 Project Description III New Building Q Addition 0 Alteration Q Plans Refer to WSEC Section 1513 for controls and commissioning req .IAN duded p lreme ty T u Iv' Compliance Option o Prescriptive 0 Lighting Power Allowance 0 Syste (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces l s D 540.0 Alteration Exceptions (check appropriate box - sec. 1132.3) Q No changes are being made to the lighting 0 Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed SPACE nit 4 26.0 104.0 SPACE Da 6 75.0 450.0 SPACE Dc 1 540.0 540.0 SPA= as 24 44.0 1056.0 SPACE MU 13 44.0 572.0 SPACE rC 1 26.0 26.0 SPACE Pr 32 37.0 1184.0 SPACE rG 16 25.0 400.0 SPACE PH 4 28.0 112.0 SPACE s 1 17.0 17.0 SPACE M 4 62.0 248.0 Location (floor /room no.) Occupancy Description Allowed Watts per ft Area in ft Allowed x Area SPACE RETAIL 1.50 1260.0 1890.0 SALES DffitCHANDISE DISPLAY 1.50 1785.0 2677.5 SPACE 2% INCREASE FOR HEIGHT PLR FOOT OF 4042.5 WATTS 0.04 4042.1 161.7 Interior Lighting Summary 11• •• •• k•1 •-• . •- • •.•- •u• .• • LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised Jriy 2007 Maximum Allowed Lighting Wattage From Table 15-1 (over) - document all exceptions on form LTG-LPA Proposed Lighting Wattage Total Allowed Watts 4729.2 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 4709.0 )R NCE a ION Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. RECEIVED 3. List all fixtures. For exemot liahtina. note section and exception number. and leave Watts/Fbcture blank. CITY OF TUKWILA DEC 19 2007 PEHMIT CENTER FILE COPY -ts,01 ri Use' v... ILPA` (W /sf) Use' LPA`(W /sf) 1.0 Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches) ' ' Convention center 1.2 Penitentiary and other 9rouo 1 -3 Occuoancies 1.0 Courthouse 1.2 Police and fire stations 1.0 Cafeterias, fast food establishments', restaurants/bars' 1.3 Post office 1.1 Dormitory 1.0 Retail' retail banking, mall concourses, wholesale stores (pallet rack shelvina) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms. day care centers 1.2 Gymnasia". assembly soaces 1.0 Theater motion picture 1.2 Health care clinic 1.0 Theater. performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses storaae areas 0.5 Hotel banquet/conference/exhibition hall'" 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate cateaories) 1.8 Parking garages 0.2 Laundriet 1.2 Libraries 1.3 Plans Submitted for Common Areas Only' Manufacturina facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms. elevator lobbies 0.8 Prescriptive Spaces Occupancy: O Warehouses, storage areas or aircraft storage hangers O Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521 ) O Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T-8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. 1 1 . S. 1 1 • • 1 - ► • 1 - • - 1 - 1 - • Off" • 11 • _ 1 - • 11 Interior Lighting Summary (back) LTG -INT 2006 Washington State Nc residential Energy Code Compliance Forms Revised July 2007 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w/ft may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three-quarter-height partitions (transparent or opaque). and lighting for free -standing display where the lighting moves with the display are exempt. An additional 1.5 w/ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Cooling Equipment Schedule Equip. ID Brand Name' Model No ' Capacity Btulh Total CFM OSA CFM or Econo? SEER or EER IPLV Location TU1omA, WA Applicant Name: AFIMAD r»HAZAB CIT OF uKW I[A 2747 19TH STREET, SAN FRANCISCO, CA 94110 CODE COMPL] NFPA 70 - P Applicant Phone: 415- 362 -5857 1 iIrl, 1 9 2007 PFl- l,rn CEN[CR Fan Equipment Schedule Equip. ID Brand Name' Model No .1 CFM SP' HP/BHP Flow Control Location of Service Efficiency' TU1omA, WA Applicant Name: AFIMAD r»HAZAB CIT OF uKW I[A 2747 19TH STREET, SAN FRANCISCO, CA 94110 CODE COMPL] NFPA 70 - P Applicant Phone: 415- 362 -5857 1 iIrl, 1 9 2007 PFl- l,rn CEN[CR Heating Equipment Schedule Equip. ID Brand Name' Model No . Capacity Btu/h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency' TU1omA, WA Applicant Name: AFIMAD r»HAZAB REVIEWED IEWED Applicant Address: 2747 19TH STREET, SAN FRANCISCO, CA 94110 CODE COMPL] NFPA 70 - P Applicant Phone: 415- 362 -5857 1 Project Info Project Address BARE ESCENTOALS Date 12/14/2007 633 SOOTHCENTER PARLAY For Building Dept. Use TU1omA, WA Applicant Name: AFIMAD r»HAZAB REVIEWED IEWED Applicant Address: 2747 19TH STREET, SAN FRANCISCO, CA 94110 CODE COMPL] NFPA 70 - P Applicant Phone: 415- 362 -5857 1 i Mechanical Summary 11• L- s as se - - a•s - •-s - i • •.•- •u• -a r.- •m MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. Q Indudes Plans i Revised July 2007 JAN - 2 208 City - 0= ukw ila Compliance Option • Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the I plans. For projects without plans, fill in the required information below. OR NCE EC Include documentation requiring compliance with commissioning requirements, SVai$ ILANG DIVJSION ' If available. 2 As tested according to Table 14-1A through 14-1G. 3 If required. ' COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). FILE COP System Description See Section 1421 for full description of Simple System qualifications. If Heating/Cooling or Cooling Only: Q Constant vol? a Split system? ■ Air cooled? Q Packaged sys? 0 <20,000 Btuh? (] Economizer induded? If Heating Only: O <5000 cfm? 0 <70% outside air? Mechanical Summary (back) 11• A. *as •/ . - l•I - • . 1- •d •H• .Ir, ILLI MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Complex Systems I Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical Permit Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address BARE EsCENTtu..s 'Date 12/14/2007 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section 'Component 'Information Required Location ' on Plans Building Department Notes " HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& dg. List heat pumps on schedule n. a. 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency RFVTFWED FOR 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss gC QE Comp NCE 1412 HVAC controls 70 NEC yes 1412.1 Temperature zones Indicate locations on plans l isIFPA yes 1412.2 Deadband control Indicate 5 degree deadband minimum JAN - 2 2000 1412.3 Humidity control Indicate humidistat 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage - f Tukwila �MCTnsON 1412.4.2 Optimum Start Indicate optimum start controls gUlLDT(1t T 1412.5 Heat pump control Indicate microprocessor on thermostat schedule , � . � 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans M 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas 1422 Thermostat interlock Indicate thermostat interlock on plans 1423 Economizers Equipment schedule 1413 Air economizers 1413.1 Air Econo Operation Indicate 100% capability on schedule 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb 1413.2 Water Econo Doc Indicate dg load & water econoe & dg tower performance 1413.3 Integrated operation Indicate capability for partial cooling 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary M2 yes 1414.2 Dud insulation Indicate R -value of insulation on dud M 2 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements 1416.2.1 Commissioning Provide commissioning plan 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report 1434 Separate air sys. Indicate separate systems on plans ' Mechanical Completed and attached. Equipment schedule with types, Summary Form ' input/output, efficiency, dm, hp, economizer I SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) REGEIVI_U 1440 Service water htg. .)IIY 01 I U KW ILA 1441 Elec. water heater Indicate R -10 insulation under tank t; 1 A 2007 yes 1442 Shut - off controls Indicate automatic shut - off E2 n.a. 1443 Pipe Insulation Indicate R -value of insulation on piping t'C MIT Calf ER 1452 Heat Pump COP Indicate minimum COP of 4.0 1452 Heater Efficiency Indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control / 1454 1454 Pool covers Pools 90+ degrees Indicate vapor re . • ant «• - r • .r a , .s Indicate R -12 • •C zz i M„+ aVM 1 Washington State Nonresidential Energy Code Compliance Form 2006 Washington State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: 2006 Washin ton State Nonresidential Ener• Code Corn • liance Form • Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14-1A through 14-1G. If a nationally recognized certification program exists for a product covered in Tables 14-1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings 225,000 Btu/h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off-hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity ( nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings 1412.8 Ventilation Controls for High -Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 efm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2006 Washin ton State Nonresidential Ener• Code Corn • liance Form • Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14-1A through 14-1G. If a nationally recognized certification program exists for a product covered in Tables 14-1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings 225,000 Btu/h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off-hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity ( nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings 1412.8 Ventilation Controls for High -Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 efm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, ,,,,, . ,, «.,..2Q06LVastsiqgtoa, State llontesidential- nergy•Gode CompliianceForm -- .._..., outlets in the first story and levels below the first story of buildings duct runs are considered building envelope until they, three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.6 Heat Pump Controls: Unitary air cooled heat pumps shall Include microprocessor controls that minimize supplemental heat usage during start-up, set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 000 EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14-5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1416 Piping Systems 1416.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) 1. a . 1513.6.1 (a) occup. sensors Schedule with type and locations yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans Completed and attached. Schedule with fixture types, 1513.7 Commissioning Indicate requirements for lighting controls commissioning 1E2 yes 1 1531 I Interior Lighting C Completed and attached. Schedule with fixture types, E2 1.a. 1 1532 E Exterior Lighting C Completed and attached. Schedule with fixture types, As •• . - ►•* - • . i • s• •u• .1 • Lighting, Motor, and Transformer Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms Project Address The following information is necessary to check a permit application for compliance with the lighting, motor, and tran requirements ip the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) LIGHTING CONTROLS (Section 1513) yes yes yes i.a. 1.a. yes .a. Code Section 1513.1 1513.2 1513.3 1513.4 1513.5 1513.6 MOTORS (Section 1511) BARE ESCENTURLS Component EXIT SIGNS (Section 1514) Local control/access Area controls Daylight zone control vertical glazing overhead glazing Display /exhib /special Exterior shut -off (a) timer w/backup (b) photocell. Inter. auto shut -off Information Required LIGHTING POWER ALLOWANCE (Section 1530 - 153 ; Schedule with type, indicate locations Maximum limit per switch Schedule with type and features, indicate locations Indicate vertical glazing on plans Indicate overhead glazing on plans Indicate separate controls Schedule with type and features, indicate location Indicate location Indicate location Indicate location . a . I 1514 I Max. watts 'Indicate watts for each exit sign . a . I 1511 I Elec motor efficiency I MECH -MOT or Equipment Schedule with hp, rpm, efficiency TRANSFORMERS (Section 1540) . a. I 1540 (Transformers 'Indicate size and efficiency If "no" is circled for any question, provide explanation: Date Lo on E2 E3 fom, REVIEWED FOR DE COMPLIANCE NFPA 70 - NEC Lion ans B JAN - 2 2008 City Of Tukwila [ LDYN D SION RECEIVED CITY OF TUKWILA DEC 19 2007 PEfiMIT CENTER FILE COPY V1/01"- 11• I. 1 1• •1 . - ke. - •'1 . 1' • •■ 1111 71 111 LTG -CHK Lighting, Motor, and Transformer Permit Plans Che • ter 12/14/2007 Revised Jtiy 2007 2008 Washington State Naresidential Energy Code Compliance Forms Building Department Notes Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as maybe required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant-sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1613.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior. Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk4o -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power fora period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior. Buildings greater than 5,000 ft and all school Classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied Fours. Within these buildings, all office areas less than 300 ft enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated in a manner requiring man( the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manure facilities as may be required for produc 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental performed are exempt from the occupe requirement. 1513.6.1 Occupancy Sensors: Occupant be capable of automatically turning off all ti area, no more than 30 minutes after the are vacated. Light fixtures controlled by occupancy sens wall- mounted, manual switch capable of tut when the space is occupied. EXCEPTION: Occupancy sensors ii allowed to have two step lighting (high- light) provided the control fails in the hi 1513.6.2 Automatic Time Switches: Autc switches shall have a minimum 7 day clock of being set for 7 different day types per we incorporate an automatic holiday "shut-off' turns off all loads for at least 24 hours and I normally scheduled operations. Automatic I shall also have program back -up capabilitie the loss of program and time settings for at power is interrupted. Automatic time switches shall incorporate switching device which: a. is readily accessible; b. is located so that a person using the de' lights or the areas controlled by the switch, area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no m when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft building footprint for footprints over 100,00( greater. 1513.7 Commissioning Requirements: F controls which include daylight or occupant automatic controls, automatic shut-off contl sensors, or automatic time switches, the lig shall be tested to ensure that control device equipment and systems are calibrated, adji. in accordance with approved plans and ape Sequences of operation shall be functionall ensure they operate in accordance with apt specifications. A complete report of test pr. results shall be prepared and filed with the notes shall require commissioning in accon paragraph. 1514 Exit Signs: Exit signs shall have an i demand of 5 Watts or less per sign. Motors - General Requirement 1511 Electric Motors: All permanently wir motors of 1 hp or more, which are not part system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are a specialized process equipment. 2. Where the motor is integral to a Ii equipment for which no complying mot approved. Transformers - General Requil SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltag distribution transformer shall be the Class I for distribution transformers specified in Tal "Guide for Determining Energy Efficiency fc Transformers" published by the National El Manufacturers Association (NEMA TP -1 -20 Revised July 2007 requiring manual operation of systems. ;trial or manufacturing process ired for production. ratory spaces. dical or dental tasks are :om the occupancy sensor rs: Occupancy sensors shall :uming off all the lights in an as after the area has been rcupancy sensors shall have a capable of turning off lights sncy sensors in stairwells are lighting (high-light and low- DI fails in the high-light position. witches: Automatic time J 7 day clock and be capable iy types per week and iday "shut-off' feature, which 24 hours and then resumes ns. Automatic time switches (-up capabilities, which prevent settings for at least 10 hours, if call incorporate an over -ride n using the device can see the by the switch, or so that the wnciated; ain on for no more than 2 hours ; and eding 5,000 ft or 5% of the s over 100,000 ft whichever is iuirements: For lighting ht or occupant sensing c shut-off controls, occupancy witches, the lighting controls t control devices, components, jalibrated, adjusted and operate plans and specifications. I be functionally tested to dance with approved plans and sport of test procedures and !filed with the owner. Drawing oning in accordance with this shall have an input power er sign. quirements ermanently wired polyphase h are not part of an HVAC action 1437. 'tors that are an integral part of ipment. i integral to a listed piece of complying motor has been ?ral Requirements ORMERS of a low voltage dry-type be the Class I Efficiency Levels specified in Table 4 -2 of the ly Efficiency for Distribution :he National Electrical JEMA TP- 1- 2002). 6 Washington State Nonresidential Energy Code Compliance Form 05 -08 -2008 BOB ROBINSON 37936 23 PL S FEDERAL WAY WA 98003 RE: Permit Application No. EL07 -791 827 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 12/19/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 06/16/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 06/16/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, / in& xc: fer Marshall 't Technician Permit File No. EL07 -791 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: EL07 - 791 DATE: 12 - -07 PROJECT NAME: BARE ESCENTUALS SITE ADDRESS: 827 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: I' A 1 ' Z 6 I ding Division Public Works Complete Comments: Documents/routing slip.doc 2-28-02 PERMIT COORD COPY `4 ` PLAN REVIEW /ROUTING SLIP -0 ' C Fire Prevention Structural DETERMINAT ON OF COMPLETENESS: (Tues., Thurs.) Incomplete TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: • APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DATE: Planning Division ❑ Permit Coordinator n DUE DATE: 12-20-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DUE DATE: 01-17 -08 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License BURKEEL022BA Licensee Name BURKE ELECTRIC LLC Licensee Type ELECTRICAL CONTRACTOR UBI 601759838 Ind. Ins. Account Id Business Type LIMITED LIABILITY COMPANY Address 1 13563 SE 27TH PL Address 2 City BELLEVUE County KING State WA Zip 98005 Phone 4256440351 Status ACTIVE Specialty I GENERAL Specialty 2 UNUSED Effective Date 1/1/1998 Expiration Date 1/1/2010 Suspend Date Separation Date Parent Company Previous License BURKEE*412L9 Next License BURKEEL967K4 Associated License BURKEDM95808 Look Up a Contractor, El 'ir"ln or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Electrical Administrator Information License Name Status BURKEDM958O8 BURKE, DOMINIC M ACTIVE Business Owner Information Name BURKE, RANDALL W Role AGENT Effective Date 01/01/1980 Expiration Date BURKE, RANDALL W PARTNER/MEMBER 01/01/1980 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= BURKEEL022BA 05/12/2008 ELECTRICAL SYMBOLS SYMBOL DESCRIPTION A a 0 3 LIGHT OUTLET a- SWITCH DESIGNATION 3 -CIRC. NO. (SEE PANEL) A- FIXTURE TYPE (SEE SCHEDULE) CONDUIT RUN CONCEALED IN WALL OR CEILING. CROSS LINES INDICATE NO. OF #12 COPPER WIRES EXCLUDING GND CONDUCTORS WHERE REQUIRED. (INSULATION TYPE THHN /TTHWN U.O.N) /// CONDUIT RUN WITH GROUND CONDUCTOR --- CONDUIT RUN W /ISOLATED GROUND CONDUCTOR - - - -- CONDUIT RUN IN FLOOR OR U.G. -X- CONDUIT RUN, EXPOSED CONDUIT STUB UP -O - a CONDUIT STUB DOWN -S- SOUND SYSTEM CONDUIT -T- TELEPHONE CONDUIT ONLY CONDUIT SEAL T I - III' GROUND CONNECTION 1 CONDUIT STUB OUT WITH CAP ] 1 2 FLEXIBLE CONDUIT PANEL MOUNTED CIRCUIT BREAKER 0- - •-o- PANEL MOUNTED FUSED SWITCH Li S SINGLE POLE SWITCH S2 TWO POLE SWITCH 53 THREE WAY SWITCH SR MOMENTARY CONTACT SWITCH SM MOTOR RATED SWITCH a DISCONNECT SWITCH, FUSED a DISCONNECT SWITCH, NON FUSED HE DIMMER SWITCH PUSH BUTTON 0 MAGNETIC MOTOR STARTER ' ' PANELBOARD SWITCHBOARD 111 l� TERMINAL CABINET TELEPHONE BACKBOARD SURFACE RACEWAY T TRANSFORMER - 0. MOTOR CONNECTION & 120V, 20A DUPLEX RECEPT. @ +15" UON c 120V, 20A DUPLEX RECEPTACLE & DOUBLE DUPLEX RECEPTACLE ® FLOOR MOUNTED RECEPTACLE CP RECEPTACLE WITH G.F.I. (I.G.) & ISOLATED GROUND RECEPTACLE HALF SWITCHED RECEPTACLE eE 208/240V RECEPTACLE 0 OR ®- SPECIAL RECEPTACLE O LOCK ON DEVICE 0 JUNCTION BOX ® FLOOR MOUNTED J -BOX H TELEPHONE OUTLET ® TELEPHONE FLOOR OUTLET b TELEPHONE /DATA OUTLET ID DATA OUTLET ❑I INTERCOM OUTLET I{9 CLOCK OUTLET OT THERMOSTAT OUTLET W CABLE TV. OUTLET Ha OR El ILLUMINATED EXIT SIGN (WALL OR CLG.) d SMOKE DETECTOR O5 MOTION SENSOR (WALL OR CLG_) SO SYSTEM SMOKE DETECTOR ABBREVIATIONS SYMBOL r DESCRIPTION A/C AIR CONDITIONING CO CONDUIT ONLY CKT CIRCUIT FLA FULL LOAD AMPERES GFI GROUND FAULT INTERRUPTER HP HORSEPOWER LTG UGHTING NIC NOT IN CONTRACT NTS NOT TO SCALE NL UNSWITCHED NIGHT LIGHT PB PULL BOX UG UNDERGROUND UON UNLESS OTHERWISE NOTED VL VERIFY LOCATION WP WEATHER PROOF RECEIVE I C;TY Or TUM FILE COPY C PART 1 - GENERAL 1.0 GENERAL 1.1 SCOPE 1.2 CONTRACT DRAWINGS THE "GENERAL CONDITIONS OF THE CONTRACT" ARE A PART OF THIS SECTION AND SHALL BE AS BINDING AS IF REPRODUCED HEREIN. A. THE WORK UNDER THIS SECTION SHALL INCLUDE FURNISHING ALL LABOR, MATERIALS, TOOLS AND EQUIPMENT REQUIRED FOR THE COMPLETE INSTALLATION OF ALL ELECTRICAL WORK AS INDICATED ON THE ELECTRICAL DRAWINGS AND AS HEREINAFTER SPECIFIED, TOGETHER WITH OTHER ITEMS OF MISCELLANEOUS WORK SO INDICATED, EXCEPTING ONLY WORK CLEARLY INDICATED TO BE DONE UNDER OTHER SECTIONS OF THESE SPECIFICATIONS OR UNDER OTHER CONTRACTS. A. IN GENERAL, THE ELECTRICAL DRAWINGS ARE DIAGRAMATIC IN NATURE AND INDICATE THE LOCATION OF OUTLETS AND EQUIPMENT AND THEIR INTERCONNECTION; AND THOUGH NOT NECESSARILY INDICATING THE ACTUAL PROPER COORDINATION WITH THE WORK OF THEIR TRADES AND IN SPACE AVAILABLE WILL PERMIT. THE DRAWINGS ARE NOT INTENDED TO BE SCALED. REFER TO THE ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND LIMITATIONS OF THE BUILDING STRUCTURE OR FINISH, AND TO THE MECHANICAL DRAWINGS FOR THE LOCATION OF EQUIPMENT OF THOSE TRADES REQUIREING ELECTRICAL SERVICE CONNECTIONS. ANY DISCREPEN CY, CONFLICT, OR QUESTIONABLE POINT SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER BEFORE COMMENCING WORK, B. "PROVIDE" MEANS FURNISH, INSTALL, AND CONNECT UNLESS OTHERWISE NOTED. 1.3 RECORD DRAWINGS A. DURING THE PROGRESS OF THE WORK, MAINTAIN ONE COMPLETE SET OF RECORD DRAWINGS AS OUTLINED UNDER GENERAL NOTE 12. AS THE WORK IS INSTALLED, NEATLY AND CLEARLY MARK ON THESE PRINTS THE FOLLOWING INFORMATION: 1. ALL DEVIATIONS FROM ORIGINAL CONTRACT DRAWINGS. 2. INFORMATION CONTAINED ON CHANGE ORDERS. 3. DIMENSIONED LOCATIONS OF CONCEALED CONDUITS. 4. DIAGRAMS OF EQUIPMENT CONNECTIONS. AT THE CONCLUSION OF THE JOB, THESE PRINTS SHALL BE DELIVERED TO THE ARCHITECT. 1.4 CODES, PERMITS, AND INSPECTIONS A. NOTHING IN THESE SPECIFICATIONS OR ON THE DRAWINGS SHALL BE INTERPRETED AS PERMISSION TO VIOLATE CODES OR ORDINANCES. ELECTRICAL WORK SHALL CONFORM TO THE LATEST EDITION OF THE FOLLOWING, AND ALL OTHER APPLICABLE, CODES AND STANDARDS: 1. STATE DIVISION OF INDUSTRIAL SAFETY, ELECTRICAL SAFETY ORDERS. 2. NATIONAL ELECTRICAL MANUFACTURERS' ASSOCIATION. 3. UNDERWRITERS' LABORATORIES 4, LOCAL CODES AND INSPECTION AUTHORITIES, 5. NATIONAL ELECTRICAL CODE FOR ALL ITEMS NOT SPECIFICALLY COVERED BY STATE OR LOCAL ORDINANCES. B. INSPECT THE JOB SITE PRIOR TO SUBMITTING A BID AND MAKE ALLOWANCE FOR EXISTING CONDITIONS WHICH MAY AFFECT THE WORK AND ARRANGE FOR AND PAY FOR TESTS AND INSPECTIONS, AND PROVIDE NOTICES REQUIRED BY ANY AND ALL LAWS, RULES, REGULATIONS, AND ORDINANCES WHICH PERTAIN TO THIS WORK, WHERE ADDITIONS OR ALTERATIONS ARE REQUIRED IN OR AT EXISTING ELECTRICAL INSTALLATION AS INDICATED. 1, INFORMATION GIVEN ON THE DRAWINGS REGARDING EXISTING INSTALLATIONS OR CONDITIONS HAS BEEN OBTAINED FROM THE BEST SOURCES AVAILABLE BUT CANNOT BE GUARANTEED ACCURATE IN ALL RESPECTS. VERIFY ALL SUCH INFORMATION BEFORE PROCEEDING WITH ANY NEW WORK THAT MAY BE AFFECTED. INCLUDE AS A PART OF THE CONTRACT ALL WORK REQUIRED TO PRODUCE THE INDICATED RESULT. 2. RELOCATE AND /OR RECONNECT EXISTING CIRCUITS WHERE CONTINUITY HAS BEEN AFFECTED OR AS MAY BE REQUIRED TO PROVIDE FOR NEW CONSTRUCTION. 3. DETACH ALL EXISTING NONSUPPORTED CONDUITS, BOXES AND ELECTRICAL DIVICES PER CODE 4. EXTEND NEW WIRING AS REQUIRED TO NEW DEVICES AND OUTLETS. PART 2 - PRODUCTS 2.1 GENERAL: A. ALL MATERIALS USED IN THE ELECTRICAL WORK HEREIN SPECIFIED SHALL BE NEW AND SUITED TO THE USE INTENDED AND SHALL BE LISTED BY THE UNDERWRITERS' LABORATORIES, INC., AND SHALL MEET THEIR REQUIREMENTS AND BEAR THEIR LABEL WHENEVER STANDARDS HAVE BEEN ESTABLISHED AND LABEL SERVICE IS REGULARLY FURNISHED BY THAT AGENCY. THE ARCHITECT RESERVES THE RIGHT TO REJECT ANY MATERIAL WHICH IN HIS OPINION IS NOT IN COMPLIANCE WITH THIS SPECIFICATION, EITHER BEFORE OR AF ILR INSTALLATION. ALL MATERIALS SHALL BE OF THE TYPES OR MAKES HEREINAFTER SPECIFIED, AND NO SUBSTITUTIONS WILL BE PERMITTED WITHOUT SUBMITTAL FOR REVIEW BY THE ARCHITECT. "PRODUCTS" AND "MATERIALS" ARE USED INTERCHANGEABLY AND MEAN MATERIALS, FIXTURES AND EQUIPMENT. 2.2 CONDUIT 2.3 WIRE AND CABLE 2.4 LIGHTING FIXTURES 2.5 WIRING DEVICES 2.6 NAMEPLATES A. PROVIDE ONLY NEW CONDUIT WITH UL LISTING OR LABEL AND DELIVER TO THE SITE IN STANDARD LENGTHS. UNLESS OTHERWISE INDICATED, PROVIDE CONDUITS FOR ALL TYPES OF CONDUCTORS OR CABLES OF ALL SYSTEMS AND VOLTAGES. 1. RIGID STEEL CONDUIT AND COUPLINGS: HOT- DIPPED GALVANIZED OR SHERARDIZED INSIDE AND OUT, WITH GALVANIZED THREADS. PROVIDE INSULATED METALLIC BUSHINGS EXCEPT THAT SIZES 1 INCH AND SMALLER MAY BE NONMETALLIC TYPE. 2. ELECTRICAL METALLIC STEEL TUBING: HOT - DIPPED GALVANIZED OR SHERARDIZED INSIDE AND OUT. PROVIDE INSULATED AND BUSHED TAP -ON TYPE CONNECTORS AND COUPLINGS AS MADE BY TOMIC OR T & B, OR WRENCH TIGHTENED SCREW TYPE. 1 FLEXIBLE CONDUIT: MANUFACTURED FROM ALUMINUM OR SINGLE STRIP GALVANIZED STEEL. PROVIDE INSULATED DIE -CAST CONNECTORS WITH RIDGES THAT THREAD INTO THE INSIDE OF THE CONDUIT TO INSURE A FORCE FIT AS MADE BY D & H ELECTRICAL COMPANY OR EQUAL. 4. LIQUIDTIGHT FLEXIBLE CONDUIT: IDENTICAL TO FLEXIBLE STEEL CONDUIT BUT WITH OVERALL POLYVINYL CHLORIDE PLASTIC JACKET. PROVIDE INSULATING CONNECTORS, APPLETON STN SERIES OR EQUAL. A. ALL WIRE AND CABLE SHALL BE ANNEALED COPPER WITH 98% CONDUCTIVITY AND 600 -VOLT INSULATION. 1. CONDUCTORS NO.10 AWG AND SMALLER SHALL BE SOLID TYPE THHN OR THW INSULATION: NO.8 AWG AND LARGER SHALL BE STRANDED TYPE THHN OR THW INSULATION. USE TYPE THW IN WET LOCATIONS, IN CONDUITS INSTALLED WITHIN OR JUST UNDER ROOFING MATERIALS AND FOR ALL AREAS EXTERIOR TO BUILDINGS. 2. CONDUCTORS INSTALLED IN AREAS SUBJECTED TO TEMPERATURES EXCEEDING 140 DEGREES F., TERMINATING IN INCANDESCENT LIGHTING FIXTURES, AND INSTALLED THROUGH OR INTO HOUSING CONTAINING BALLASTS, SHALL BE TYPE AVA. 3. FOR ALL SIZES, CONDUCTORS WITH MINERAL FILLED CROSSLINKED THERMOSETTING POLYETHYLENE INSULATION, UL TYPE XHHW RATED 75 DEGREES C. IN WET OR DRY LOCATIONS MAY BE USED. A. PROVIDE RECESSED, SURFACE AND PENDANT MOUNTED LIGHTING FIXTURES, COMPLETE WITH LAMPS, AND BALLASTS WHERE REQUIRED, AS SHOWN OF THE DRAWINGS AS SPECIFIED. 1. FLUORESCENT BALLASTS OF PROPER TYPE AND CHARACTERISTICS FOR THE LAMPS IN THE FIXTURE AND WITH VOLTAGE RATING AS REQUIRED BY THE CIRCUIT WHICH THE FIXTURE IS CONNECTED. 2. PROVIDE LAMPS AS INDICATED ON THE DRAWINGS. A. WIRING DEVICES SHALL BE OF THE MOLDED COMPOSITION SPECIFICATION GRADE. ALL DEVICES SHALL BE FLUSH MOUNTED UNLESS OTHERWISE NOTED AND WITH FINISH MATCHING DEVICE PLATES. LOCAL SWITCHES SHALL HAVE ALTERNATING CURRENT RATINGS EQUAL TO FULL NOMINAL CAPACITY. 1. RECEPTACLES: PROVIDE TYPE IN ACCORDANCE WITH NEMA STANDARD CONFIGURATION AS SHOWN. 2. SWITCHES: SINGLE POLE, 3 -WAY AND 4 -WAY AS SHOWN, FINISH AS SELECTED. 3. PROVIDE PLATES FOR ALL OUTLET BOXES AND FITTINGS OF ALL SYSTEMS EXCEPT AT OUTLETS WHERE FIXTURE CANOPIES ARE USED. A. PROVIDE A NAMEPLATE FOR EACH PANELBOARD, DISCONNECT SWITCH, AND FOR ANY OTHER CONTROL DEVICE OR MAJOR ITEM OF ELECTRICAL EQUIPMENT, AS FOLLOWS: 1. PROVIDE BLACK -ON -WHITE LAMINATED PLASTIC NAMEPLATES ENGRAVED IN 1/4" HIGH LETTERS TO CORRESPOND WITH THE DESIGNATIONS ON THE DRAWINGS. PROVIDE OTHER OR ADDITIONAL INFORMATION ON NAMEPLATES WHERE INDICATED. 2. ATTACH NAMEPLATES TO EQUIPMENT WITH RIVETS, BOLTS, OR APPLICABLE SHEET METAL SCREWS. GLUE -ON TYPES AND POPRIVET TYPES ARE NOT ACCEPTABLE. 3. PROVIDE DYMO TYPE PLASTIC TAPE FOR EACH RECEPTACLE AND J -BOX INDICATING CIRCUIT NUMBERS AND PANEL. PROVIDE ADDITIONAL INFORMATION AS INDICATED ON THE DRAWINGS. THE COLOR CODE FOR THE TAPES SHALL BE AS FOLLOWS: A. ORANGE FOR ISOLATED GROUND CIRCUITS B. BLACK FOR STANDARD 120V CIRCUITS 2.7 OUTLETS A. OUTLET AND JUNCTION BOXES USED IN CONCEALED WORK, SHALL BE GALVANIZED OR SHERARDIZED ONE- PIECE, PRESSED STEEL. KNOCK -OUT TYPE SIZED IN ACCORDANCE WITH THE CODE FOR THE NUMBER OF CONDUCTORS OR THE NUMBER AND SIZE OF CONDUITS ENTERING THE BOX, BUT SHALL NOT BE LESS THAN 4" SQUARE AND 1 -1/2" DEEP. PLASTER RINGS SHALL BE PROVIDED FOR ALL FLUSH MOUNTED BOXES. APPROVED PI , �; °'�T ; r to C: LANCED, MODIFIED CR ALTERED WITHOUT AUTHORIZATION FROM THE BL',I,DWG Or :,wL, ALI WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND IS 313 4 ,'T TO FIFLC INSPECTIONS 2.8 SAFETY SWITCHES A. PROVIDE SWITCHES WITH THE NUMBER OF POLES AND THE VOLTAGE, CURRENT AND HORSEPOWER RATINGS AS REQUIRED. PROVIDE EXTERNALLY OPERABLE, QUICK -MAKE, QUICK -BREAK TYPE WITH COVER INTERLOCK AND PADLOCKABLE IN EITHER THE OPEN OR CLOSED POSITION. UNLESS INDICATED OTHERWISE, PROVIDE SWITCHES INDOORS IN NEMA TYPE 1 ENCLOSURE AND OUTDOORS, OR WHERE INDICATED TO BE WEATHERPROOF IN NEMA TYPE 3R RAIN -TIGHT ENCLOSURE. SWITCHES SHALL BE HEAVY -DUTY TYPE MEETING NEMA SPECIFICATIONS KS1 -2.02. PROVIDE NAMEPLATES INDICATING EQUIPMENT SERVED. PROVIDE UNIT AS MANUFACTURED BY GENERAL ELECTRIC, SQUARE -D OR CUTTLER - HAMMER. 2.9 PANELBOARD A. PROVIDE SURFACE MOUNTED PANELBOARD WITH MAIN LUGS, SUBFEED LUGS, BUS SIZE AND CIRCUIT BREAKERS OF A RATING AS SHOWN ON THE DRAWINGS. B. CIRCUIT BREAKERS SHALL BE BOLT -ON TYPE WITH INTERRUPTING CAPACITY AS SHOWN ON THE PANEL SCHEDULE. SINGLE POLE BREAKERS SHALL BE FULL MODULE SIZE. MULTIPOLE BREAKERS SHALL BE OF THE COMMON TRIP TYPE HAVING A SINGLE HANDLE. C. PROVIDE NEATLY TYPED CIRCUIT DIRECTORY CARD, CLEARLY IDENTIFYING ALL CIRCUITS, MOUNTED IN A CARD HOLDER, BEHIND HEAVY PLASIC ON THE INSIDE OF THE HINGED DOOR D. PROVIDE PANELBOARDS MANUFACTURED BY "SQUARE D ", CUTTLER - HAMMER OR GENERAL ELECTRIC. 2.10 TRANSFORMERS A. PROVIDE DRY TYPE, COPPER WINDING, SELF - COATED, VENTILATED TRANSFORMERS FOR USE ON 60 -CYCLE SYSTEM WITH THE FOLLOWING CHARACTERISTICS: 1. RATINGS: PHASE, VOLTAGE AND CONNECTION ARRANGEMENT AS INDICATED. 2. INSULATION: CLASS H 115 C AVERAGE CONDUCTOR TEMPERATURE RISE. 3. TAPS: FOUR 2 -1/2 PERCENT PRIMARY TAPS, TWO ABOVE AND TWO BELOW RATED VOLTAGE. 4. MOUNTING: TRANSFORMERS SHALL BE FURNISHED COMPLETE WITH MOUNTING CHANNELS AND MOUNTING BOLTS. ENCLOSURES SHALL BE PROVIDED WITH LIFTING LUGS AND JACKING PLATES AS REQUIRED. 5. VIBRATION DAMPENING: CONSTRUCTED WITH BUILT -IN VIBRATION DAMPERS WITCH COMPLETELY ISOLATE THE CORES AND COILS FROM ALL SUPPORTS AND ENCLOSURES. 6. SOUND RATINGS: IN THE INSTALLED CONDITION, THE SOUND LEVELS SHALL NOT EXCEED 50 DB. TRANSFORMERS SHALL BE MANUFACTURED BY SQUARE "D ", GENERAL ELECTRIC, CUTTLER - HAMMER OR WESTINGHOUSE. PART 3 - EXECUTION 3.1 MATERIALS AND WORKMANSHIP 3.2 WIRE A. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH RECOMMENDATIONS OF THE MANUFACTURER TO CONFORM WITH THE CONTRACT DOCUMENTS. THE INSTALLATION SHALL BE ACCOMPLISHED IN CONFORMANCE WITH THE APPLICABLE RULES. AND WIRING METHODS A. ALL WIRING AND CABLE INCLUDING LOW VOLTAGE AND CONTROL CIRCUITS SHALL BE INSTALLED IN CONDUIT UNLESS OTHERWISE NOTED. 1. COLOR CODE ALL BRANCH CIRCUIT AND CONTROL CIRCUIT WIRING BY MEANS OF FACTORY COLOR CODED CONDUCTORS. EACH PHASE SHALL BE THE SAME COLOR THROUGHOUT THE SYSTEM AND SHALL BE A DIFFERENT COLOR FROM OTHER PHASES AND OTHER SYSTEMS THE IDENTIFIED NEUTRAL CONDUCTOR SHALL BE WHITE, AND GROUND WIRES SHALL BE GREEN. 3.3 CONDUIT AND TUBING A. EXCEPT WHEN OTHERWISE INDICATED AS MORE STRINGENT, PROVIDE THE TYPE OF CONDUIT LEGALLY PERMITTED OR REQUIRED FOR EACH LOCATION OR CONDITION. UNLESS INDICATED OTHERWISE, CONDUITS SHALL BE CONCEALED WHERE POSSIBLE WITHIN OR BEHIND FINISHED WALLS OR CEILINGS. 1. ELECTRICAL METALLIC TUBING (EMT) MAY BE INSTALLED ONLY WITHIN BUILDINGS ABOVE GRADE IN DRY LOCATIONS AND WHERE NOT SUBJECT TO MECHANICAL INJURY OR OTHERWISE PROHIBITED. 2. USE RIGID METAL CONDUIT WHERE LEGALLY REQUIRED, WHERE EXPOSED TO THE WEATHER; ALSO WHERE SUBJECT TO MECHANICAL INJURY, HERE DEFINED AS EXPOSED CONDUIT LESS THAN 7' -6" ABOVE THE FLOOR, WHERE UNDERGROUND, AND WHERE OTHER TYPES OF CONDUITS ARE NOT ALLOWED UNDER THIS SPECIFICATION. B. PROVIDE A GREEN INSULATION GROUNDING CONDUCTOR OF SIZE AS REQUIRED BY CODE IN ALL FLEXIBLE CONDUITS OR OTHER CONDUIT RUNS HAVING A LENGTH OF FLEXIBLE CONDUIT AS ANY PART OF THE RUN. USE FLEXIBLE CONDUIT ONLY AS FOLLOWS: A. WHERE INDICATED. B. FINAL CONNECTIONS TO MOTORS, TRANSFORMER, VIBRATING EQUIPMENT OR WHERE REQUIRED FOR EQUIPMENT SERVICING. C. CONNECTIONS TO RECESSED LIGHTING FIXTURES FROM NEARBY ACCESSIBLE JUNCTION BOXES. D. CONCEALED RUNS IN DRY LOCATIONS WHERE STRUCTURAL CONDITIONS PREVENT THE USE OF OTHER TYPES OF CONDUIT. E. IN DAMP LOCATIONS OR AREAS EXPOSED TO THE WEATHER, FLEXIBLE CONDUIT, WHERE REQUIRED, SHALL BE OF THE LIQUID -TIGHT TYPE PROVIDED THE JACKET TEMPERATURE LIMITATIONS WILL NOT BE EXCEEDED. C. SUPPORT CONDUIT AT LEGAL INTERVALS. PROVIDE ADDITIONAL SUPPORTS WHERE OBVIOUSLY REQUIRED OR AS DIRECTED. R: '; ;c' NS No oharlpa� s!vil `�e made to th^ Srnnrn Of work without prior approval of Tukwila Building Division. I I NOTE: R evisions will require a new plan submittal and may include 8dditinn2l nlan re„l^L,, fees. 1 3.4 LIGHTING FIXTURES 3.6 TESTS 4.0 1. 2. 3. 4, 3.5 EQUIPMENT CONNECTIONS 3.7 CUTTING AND PATCHING WARRANTY Ran MAW approval b subject to errors and am. Appl'OYa1 of consbuction documents does Apt &Mori= the violation of any adopted code or cedinema Receipt of approved Reid 4 -. condi= is By Dew City of Tkikwila BUILDING DIVISION A. FURNISH AND INSTALL FIXTURES COMPLETE IN CONFORMANCE WITH THE SPECIFICATION, THE REQUIREMENTS SPECIFIED BELOW, AND DETAILED ON THE DRAWINGS. DETAILS SHOWN ON THE DRAWINGS ARE INDICATIVE OF THE GENERAL TYPE DESIRED AND ARE NOT INTENDED TO RESTRICT SELECTION TO FIXTURES OF ANY PARTICULAR MANUFACTURER. (SUBMIT FOR ARCHITECTS APPROVAL) LIGHTING FIXTURES SHALL BE SET PLUMB, SQUARE, LEVEL, AND IN ALIGNMENT AND SHALL BE SECURED IN ACCORDANCE WITH THE MANUFACTURERS' DIRECTIONS AND SHOP DRAWINGS EXCEPT AS OTHERWISE NOTED. ACCESSORIES SUCH AS STRAPS, MOUNTING PLATES, NIPPLES, OR BRACKETS SHALL BE PROVIDED FOR PROPER INSTALLATION. FOR FLUORESCENT FIXTURES, THE CATALOG NUMBERS ARE THOSE FOR INDIVIDUAL UNITS. WHERE CONTINUOUS ROWS ARE INDICATED, PROVIDE ALL NECESSARY ACCESSORIES. WHERE SINGLE -LAMP FIXTURES ARE INDICATED IN CONTINUOUS ROWS PROVIDE TANDEM UNITS WITH 2 -LAMP BALLASTS WHEREVER POSSIBLE. WHERE FIXTURES ARE FOR LAY -IN MOUNTING IN AN EXP RUNNER TYPE OF CEILING, THE ADDITIONAL CEILING WIRE TIES FOR THE FIXTURES WILL BE PROVIDED AS PART OF THE CEILING WORK. THIS CONTRACTOR SHALL INSTALL A TIE OFF EACH FIXTURE. IN SUCH CEILINGS OR SIMILAR, PROVIDE EACH FIXTURES WITH CUPS (4 REQUIRED) OR EQUIVALENT MEANS TO PREVENT THE ACCIDENTAL DISENGAGEMENT OF THE FIXTURE FROM THE CEILING. LAMPS OF THE PROPER SIZE, TYPE, WATTAGE, AND VOLTAG RATINGS AS INDICATED ON THE DRAWINGS SHALL BE DELIVERED TO THE PROJECT IN THE ORIGINAL CARTONS ANL�? INSTALLED IN THE FIXTURES JUST PRIOR TO THE COMPLETION OF THE PROJECT. LAMPS THAT HAVE BEEN USED DURING THE CONSTRUCTION SHALL BE REPLACED WITH NEW UNITS SO AS TO ASSURE A NEW INSTALLATION AT THE TIME OF FINAL ACCEPTANCE. A. ALL WIRING FOR THE CONNECTION OF MOTORS AND CONTROL EQUIPMENT AS INDICATED ON THE DRAWING SHALL BE FURNISHED AND INSTALLED UNDER THIS SECTION OF THESE SPECIFICATIONS. B. FLEXIBLE CONNECTIONS OF SHORT LENGTH SHALL BE PROVIDED FOR EQUIPMENT SUBJECT TO VIBRATION OR MOVEMENT AND FOR ALL MOTORS. LIQUID -TIGHT FLEXIBLY CONDUIT SHALL BE USED IN WET LOCATIONS. A SEPARATE GROUND CONDUCTOR SHALL BE PROVIDED ACROSS ALL FLEXIBLE CONNECTIONS. A. IN ADDITION TO TEXTS REQUIRED BY OTHER SECTIONS, PERFORM OR CAUSE TO BE PERFORMED, ANY TESTS SPECIFIED FOR ELECTRICAL WORK WHEN THE WORK IS SUBSTANTIALLY COMPLETE, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 1. UPON COMPLETION OF THE WORK AND ADJUSTMENT OF ALL EQUIPMENT, CONDUCT AN OPERATING TEST AND SUBMIT FOR APPROVAL AT SUCH TIME AS THE ARCHITECT DIRECTS. CONDUCT THE TEXT IN THE PRESENCE OF AN AUTHORIZED REPRESENTATIVE OF THE ARCHITECT. DEMONSTRATE THAT ALL SYSTEMS AND EQUIPMENT ARE: A. OPERATING IN ACCORDANCE WITH ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS. B. FREE FROM ALL ELECTRICAL AND MECHANICAL DEFECTS. C. FREE FROM SHORT CIRCUITS AND GROUNDS OTHER THAN INTENTIONAL GROUNDS. 2. CONDUCT ALL OTHER AND ADDITIONAL TESTS THAT ARE REQUIRED BY AUTHORITIES HAVING JURISDICTION OR ARE REQUESTED BY THE ARCHITECT. 3. ALL COSTS INCURRED, INCLUDING REQUIRED INSTRUMENTS AND PERSONNEL FOR THE TESTS, SHALL BE PAID FOR BY THE CONTRACTOR. A. BE RESPONSIBLE FOR THE CUTTING AND PATCHING OF ROUGH OR FINISH WORK REQUIRED BY THIS INSTALLATION. PATCHING SHALL BE OF THE SAME MATERIAL, FINISH AND WORKMANSHIP AS THE ORIGINAL WORK, AND WHEN REQUIRED BY THE ARCHITECT, DONE BY MECHANICS OF THE ORIGINAL TRADE AT CONTRACTOR'S EXPENSE. A. UNCONDITIONALLY WARRANT FOR ONE YEAR EVERY PART OF THE WORK EXCEPT THAT FLOURESCENT BALLASTS SHALL BE WARRANTED FOR (2) YEARS. FURNISH MANUFACTURERS' WARRANTIES. ALL WARRANTIES SHALL START FROM THE TIME OF ACCEPTANCE OF THE COMPLETED PROJECT BY THE OWNER. R FOR E SC COMPLIANC IVD NFPA 70 Public Works, Building Division PERMIT NUMBER SA N - 2 Lei NOTE TO THE CONTRACTOR: DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. A ukwila r M Q UE.0 I LU ILA Fi rslvi, I : ER • • • associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PI-I: 415 - 362 -5857 FX: 415-362-5044 B ARE E SCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS, ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEMI WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET H z w 4t4 U cD -1 W ‘4 0 0 0 PROJ. NO.: PM: JC: CHECKED: 7.112 A.M. A.C. SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: SYMBOLS AND NOTES E -1 Riga !" finny F ILL uur 120/208 BUS, , 10000 A.I.C. R PA\ FL: ,5 L A " MAIN 100A C.B. (W/ GND. BUS) FLUSH MOUNT CT No C.B. OUTLETS LOAD (VA) L.C.L LOAD DESCRIPTION AMP P LTG REC ETC L -1 L -2 L -3 1 20 1 24 768 / / GENERAL LTG. 3 20 1 36 . 1152 /i j / 5 20 1 19 � 836 7 20 1 23 1012 . �f/// 9 20 1 38 / 1184 ` / /i 11 20 1 20 j// 460 460 13 20 1 9 700 fff // 15 20 1 / 800 j //i SPARE 17 20 1 5 3 j 220 220 NL & EXIT SIGNS 19 20 1 7 1 390 ff� /// STOCKROOM 21 20 1 1 / 600 //� SECURITY 23 20 1 1 j/ 1100 SHOW WINDOW 25 20 1 2 600 DOOR HOLDERS 27 20 1 4 / j 72 O/� 720 j //� GENERAL RECEPT. 29 20 1 1 300 SPRINKLER CONTROLLER 31 20 1 4 720 //� GENERAL RECEPT. 33 20 1 1 / j 600 j //� 600 PLASMA TV 35 20 1 0 SPARE 37 20 1 0 SPARE 39 20 1 0 / /i SPARE 41 20 1 /////// 0 SPARE 2 20 1 2 360 / / / / / //j OFFICE 4 20 1 2 / / 600 /� TELE. BKBD. 6 20 1 5 j / 900 STOCKROOM /RESTROOM 8 20 1 1 1200 //f 1200 SIGN 10 20 1 / 0 // SPARE 12 20 1//� 1500 SPARE 14 20 1 2 600 /� P.O.S. 16 20 2 1 1150 / EWH -1 18 /, 1150 - - -- 20 20 1 1 500 /� WATER METER 22 20 1 0 j�� SPARE 24 20 1 j / //� 0 SPARE 26 20 1 0 �ff // SPARE 28 20 1 7 0 j / / 30 20 1 j /� 0 32 20 1 0 /��� . 34 20 1 / 0 / //, 36 20 1 0 38 20 1 0 / //� 40 20 1 0j 42 20 1 j / / / / / / /// 0 T TOTAL LOAD AND SPARE 25% OF L.C.L TOTAL 6850 6806 6466 8522 V, 3 PH = 62 AMPS 20122 VA. 2131 VA. 22253 VA. © 120/208 SPECIFIC \OTES 1 2 3 4 EXISTING MAIN SWITCHBOARD WITH ASSOCIATED SEVICES TO REMAIN. VERIFY AT THE SITE. VERIFY EXACT LOCATION OF EXISTING 480V, 200A, 3P DISCONNECT SWITCH PROVIDED BY LANDLORD, INSTALL A GUTTER AS SHOWN. VERIFY EXACT LOCATION AT THE SITE. PROVIDE 480V, 60A, 3P DISCONNECT SWITCH WITH 40A CLASS RK -1 FUSES FOR CONNECTION TO NEW TRANSFORMER AS SHOWN. NEW 30 KVA, 480V — 120/208V, 30, 4W, COPPER WINDING DRY TYPE TRANSFORMER TO BE MOUNTED ON WALL ABOVE PANEL "LA ". PROVIDE ALL REQUIRED MOUNTING HARDWARE PER MANUFACTURER'S RECOMMENDATIONS. PROVIDE 3/4 "C, 1 #6 GND., CONNECT TO BLDG GND. STEEL STRUCTURE AND BOND TO MAIN COLD WATER PIPE. 1 —LI \L \0 ?LS A. B. C. D. E. F. L3A sJ V V GUTTER VAIN SWITCHBOARD 277/480 V, 30, 4W EXISTING FEEDER <10' "TA" 30 KVA 480V- 120/208V <10' 0 0- PANEL "LA" NOTE: ALL ITEMS ARE NEW U.O.N. ARY 3/4 "C, 3 #8 1 1/2"C, 4 #1 +1 #6 GND. 1 B DIAGRAIV ALL SWITCHES SHALL HAVE REJECTION CLIP. ALL FUSES SHALL BE CURRENT LIMITING, CLASS "RK -5 ". ALL WIRING SHALL BE TYPE THHN /THWN, CU CONDUCTORS, U.O.N.. ALL DEVICES SHALL BE LISTED BY U.L. OR ANY APPROVED TESTING LAB FOR INTENDED USE. ALL FEEDER LENGTHS ARE SHOWN FOR VOLTAGE DROP CALC'S ONLY. ALL DEVICES SPECIFIED ARE SQUARE D PRODUCTS. DESIGN LOAD ( ©100 %) 100A NEW TOTAL CONNECTED LOAD (PANEL "LA ", INCLUDING SPARE (Sc L.C.L. LOADS) — 62A LO17ctI PVIE CE CODE � 0 - NEC NF r;,,,. „�a CltY Of Tukwila ILDI$G DIVISION N.T.S. RECEIVED CITY OF TUKWILA DEC 19 2007 PEHMI i" c. i ER • • tl associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415 - 362 -5857 FX 415-362-5044 B ARE E SCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO. TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF TMEMI WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBC[EU. REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET 4t4 z U (/) a) C (1) >.% CO a5 CO C 01) a "Ci — a Q ., u O 4t U R:1 w CD Cr) a PROJ. NO.: PM: JC: CHECKED: 7.112 A.M. A.C. SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: SINGLE LINE DIAGRAM E -2 FIXTURE SCHEDULE SYMBOL & TYPE DESCRIPTION MOUNT VOLT. LAMP TOTAL V.A. NOTE NO TYPE DA 0 PENDENT MOUNT FLUOR. FIXTURE RESOLUTE # 5100 SERIES PEND. 120 1 26W PL 26 FINISH: PROGENY BLONDE DB A ki WALL SCONCE MURRAY FEISS LTG. # WB1218BRB SURFACE 3 25 W INC. 75 FINISH: BLANCHED PATINA DC O CHANDELIER ELK LIGHTING, ROCOCO SERIES # ELK 271 7 -8 -1 -120 CHAIN HUNG 9 60W 540 FB r.7 L(o u CALCULITE HID ADJUSTABLE ACCENT LT. LIGHTOLIER # C4T4A- CCDP- MHT4RNF- C4A39T4E1 REC. 1 39 MH 4.5 44 FB1 rte _, "0" L% ,iJ CALCULITE HID ADJUSTABLE ACCENT LT. LIGHTOLIER # C4T4A- CCDP- MHT4RF- C4A39T4E1 REC. 1 39 MH 4.5 44 FC 0 CALCULITE COMPACT FLUORESCENT LT. LIGHTOLIER # 8021 CCDP- 56132BU REC. 1 26W PL 26 FF RECESSED FLUORESCENT WALL WASHER LIGHTOLIER # 315STX- 302MRIC9X REC. 1 37W MR16 37 FG 1-- --0-- --1 4' OPEN STRIP FLUORESCENT FIXTURE BARTCO LIGHTING # BFL800 -1 T/32 -120 SURFACE 1 25W T8 25 FN 1 ---0-- --1 4' OPEN STRIP FLUORESCENT FIXTURE LIGHTOLIER # CL- 1 -4 -E81 -120 SURFACE 1 28W T8 28 J ® BASIC BATH STRIP ARTEMIDE # RZK-BASICBTH SURFACE 1 17W T8 17 CENTER ABOVE MIRROR M LOW - PROFILE WRAPAROUND LITHONIA LIGHTING # LB- 2- 32- 120 -GEB SURFACE 2 32W T8 62 0 EM EMERGENCY LIGHTING McPHILBEN # CAX6 SURFACE I 2 6W MR16 HALOGEN 12 USE BA I I LRY UNIT MINIMUM OF 90 MIN. X 0 RENAISSANCE SERIES MULE LIGHTING # CEL -B SURFACE 1 LED 4 USE BA I ILRY UNIT MINIMUM OF 90 MIN. --- B 7 B ' �"�o\ • — � .�� � P�{o—_ \ ./.,s2_ iJ�/ r --... 6 i�'ri � L`at1 1 / 7 ,. NNL ", s . SPECIFIC NOTES 1 2 LIGHTING NOTES 1) k) L L _ J� DOOR BELL SPEAKER. RUN 1/2"C.O. WITH PULL WIRE TO P.A. SYSTEM UNIT LOCATION. VERIFY AT THE SITE. SALES AREA LIGHTING CONTROL SWITCH BANK. VERIFY EXACT LOCATION WITH ARCHITECT. a) ALL LIGHT FIXTURES SHALL BE BARE ESCENTUALS STANDARDS AND BE FURNISHED AND INSTALLED BY THE CONTRACTOR, U.D.N. PROVIDE FIXTURE SUBMITTAL FOR APPROVAL PRIOR TO PLACING THE ORDER. b) VERIFY TYPE OF CEILING, MOUNTING DETAILS, REQUIRED HANGERS & FASTENERS, TRIMS AND VOLTAGE PRIOR TO PLACING THE ORDER. c) ALL RECESSED DOWNLIGHTS TO BE THERMALLY PROTECTED PER N.E.C. & U.L. REQUIREMENTS . d) USE ENERGY EFFICIENT FLUOR. LAMPS, (T8, PL, ETC.) & ELECTRONIC BALLAST FOR ALL FLUORESCENT LIGHT FIXTURES. e) VERIFY EXACT LOCATION OF ALL LIGHT FIXTURES & MOUNTING HEIGHTS PRIOR TO ANY WORK. f) INSTALL SWITCHES & DIMMERS IN A GANG BOX UNDER COMMON COVERPLATE, WHERE APPLICABLE, g) ALL LIGHT FIXTURES USED IN THE PROJECT SHALL BE LISTED FOR INTENDED USE. h) EXIT SIGNS: REVIEW BUILDING DEPARTMENT APPROVED ARCHITECTURAL REFLECTED CEILING PLAN FOR ANY REVISIONS ON REQUIRED QUANTITY, FACES, DIRECTIONAL ARROWS PRIOR TO PLACING THE ORDER. i) PROVIDE ASTRONOMICAL TIME CLOCK FOR LIGHTING CONTROL PER BARE ESSENTUAL REQUIREMENTS. "NL" INDICATES 24 HR. UNSWITCHED NIGHT LIGHT WITH EMERGENCY BA I I tRY PACK UNIT. BATTERY SHALL HAVE MINIMUM OF 90 MINUTES OPERATION CAPACITY AT FULL LOAD. PROVIDE ALL REQUIRED MOUNTING HARDWARE FOR CHANDELIER PER MANUFACTURER'S RECOMMENDATIONS. m) STORE FRONT, SHOW WINDOW & SIGN SHALL BE CONTROLLED BY TIME CLOCK & BE "ON" FROM DUSK TO 12:00 AM n) ALL J -BOX'S SHOULD BE PLACED AT THE HEIGHT OF S' -O ". STOCKROOM LA -17 FC H.C. UNISEX RESTROOM /iiiii rii/ a 0 0- /I PI 19c '0 J 19 � �jjj/2 I I= I■ 61 I dt 19a ,� ►rif_L�1 • bi i!! i b I� 1a 1ai I it - 5!b I O A r 1 O %f/ �\ 17 7e z L- 0 5c� 5c 5�; L O A 5c u _7e 5c '�0-- IH-rr rP -r L 7e r L - 5c 7NLa r 7e 5c SALES r 7e 5c L ° L -° L `O Jt L`° LbeJ 7e p r �p i gip r r 7e 5c 17-7-1 r r ri 7. i 7er 7e 5c 7e 5c 4 r - - III —�i:; 7e 5c I O iy O J L‘1 0,4 Imp bi I \'/ i 3bi b � 1\ / I 3b 1 � .1 1\ 3b 1 i 1ai 1a r 1 1ai 1a1 1 r 1 1a1 1a 1 �ri .. 1 i 31 i i ` I i i t , 9 17NL\ l o. `p ■b _q —q —„, —,q — — — —q —a 7 5c 7e 13m L'�!J 7e 13 r' vo 13k FC ' B1 17NL d 13 13m LA -19 SWITCH BANK 2 LA -9,11 (VIA SW g,h) LIGHTING PLAN SCALE: 1/4"=1-0" PA e 19 /216e- I i co6 - rc 41-6 t-aatmi/y1/0 phi 4/07 fit 4644(6 / e/m/ / # O /sc(f 4R LA-- 1,3 -5,7 (VIA SW a,b,c,d,e) r rfik -Alt 4 ' I ' II!` r . 11010 9• 9. 9 • 9•i 94 9qI %�— TYPICAL 1 = = = i LA -13 (VIA SW j,k,m) ELOT q REVIEWED FOR COMPLIANCE CODE A � P NEC NF JAN - ? Iu8 City6Tuk BUILDING D RECEIVED CITY OF TUKWILA DEG 1 9 2007 PEHMIT CENTER • • • associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415 - 362 -5857 FX: 415-362-5044 B ARE E SCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO. TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND/OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SEf H z U a) C C) _C 0 C!) 0 I PROJ. NO.: PM: JC: CHECKED: 7.112 A.M. A.C. SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: LIGHTING PLAN E -3 g Q9: u Q9; a ` SPECIFIC NOTES 1 2 LIGHTING NOTES 1) k) L L _ J� DOOR BELL SPEAKER. RUN 1/2"C.O. WITH PULL WIRE TO P.A. SYSTEM UNIT LOCATION. VERIFY AT THE SITE. SALES AREA LIGHTING CONTROL SWITCH BANK. VERIFY EXACT LOCATION WITH ARCHITECT. a) ALL LIGHT FIXTURES SHALL BE BARE ESCENTUALS STANDARDS AND BE FURNISHED AND INSTALLED BY THE CONTRACTOR, U.D.N. PROVIDE FIXTURE SUBMITTAL FOR APPROVAL PRIOR TO PLACING THE ORDER. b) VERIFY TYPE OF CEILING, MOUNTING DETAILS, REQUIRED HANGERS & FASTENERS, TRIMS AND VOLTAGE PRIOR TO PLACING THE ORDER. c) ALL RECESSED DOWNLIGHTS TO BE THERMALLY PROTECTED PER N.E.C. & U.L. REQUIREMENTS . d) USE ENERGY EFFICIENT FLUOR. LAMPS, (T8, PL, ETC.) & ELECTRONIC BALLAST FOR ALL FLUORESCENT LIGHT FIXTURES. e) VERIFY EXACT LOCATION OF ALL LIGHT FIXTURES & MOUNTING HEIGHTS PRIOR TO ANY WORK. f) INSTALL SWITCHES & DIMMERS IN A GANG BOX UNDER COMMON COVERPLATE, WHERE APPLICABLE, g) ALL LIGHT FIXTURES USED IN THE PROJECT SHALL BE LISTED FOR INTENDED USE. h) EXIT SIGNS: REVIEW BUILDING DEPARTMENT APPROVED ARCHITECTURAL REFLECTED CEILING PLAN FOR ANY REVISIONS ON REQUIRED QUANTITY, FACES, DIRECTIONAL ARROWS PRIOR TO PLACING THE ORDER. i) PROVIDE ASTRONOMICAL TIME CLOCK FOR LIGHTING CONTROL PER BARE ESSENTUAL REQUIREMENTS. "NL" INDICATES 24 HR. UNSWITCHED NIGHT LIGHT WITH EMERGENCY BA I I tRY PACK UNIT. BATTERY SHALL HAVE MINIMUM OF 90 MINUTES OPERATION CAPACITY AT FULL LOAD. PROVIDE ALL REQUIRED MOUNTING HARDWARE FOR CHANDELIER PER MANUFACTURER'S RECOMMENDATIONS. m) STORE FRONT, SHOW WINDOW & SIGN SHALL BE CONTROLLED BY TIME CLOCK & BE "ON" FROM DUSK TO 12:00 AM n) ALL J -BOX'S SHOULD BE PLACED AT THE HEIGHT OF S' -O ". STOCKROOM LA -17 FC H.C. UNISEX RESTROOM /iiiii rii/ a 0 0- /I PI 19c '0 J 19 � �jjj/2 I I= I■ 61 I dt 19a ,� ►rif_L�1 • bi i!! i b I� 1a 1ai I it - 5!b I O A r 1 O %f/ �\ 17 7e z L- 0 5c� 5c 5�; L O A 5c u _7e 5c '�0-- IH-rr rP -r L 7e r L - 5c 7NLa r 7e 5c SALES r 7e 5c L ° L -° L `O Jt L`° LbeJ 7e p r �p i gip r r 7e 5c 17-7-1 r r ri 7. i 7er 7e 5c 7e 5c 4 r - - III —�i:; 7e 5c I O iy O J L‘1 0,4 Imp bi I \'/ i 3bi b � 1\ / I 3b 1 � .1 1\ 3b 1 i 1ai 1a r 1 1ai 1a1 1 r 1 1a1 1a 1 �ri .. 1 i 31 i i ` I i i t , 9 17NL\ l o. `p ■b _q —q —„, —,q — — — —q —a 7 5c 7e 13m L'�!J 7e 13 r' vo 13k FC ' B1 17NL d 13 13m LA -19 SWITCH BANK 2 LA -9,11 (VIA SW g,h) LIGHTING PLAN SCALE: 1/4"=1-0" PA e 19 /216e- I i co6 - rc 41-6 t-aatmi/y1/0 phi 4/07 fit 4644(6 / e/m/ / # O /sc(f 4R LA-- 1,3 -5,7 (VIA SW a,b,c,d,e) r rfik -Alt 4 ' I ' II!` r . 11010 9• 9. 9 • 9•i 94 9qI %�— TYPICAL 1 = = = i LA -13 (VIA SW j,k,m) ELOT q REVIEWED FOR COMPLIANCE CODE A � P NEC NF JAN - ? Iu8 City6Tuk BUILDING D RECEIVED CITY OF TUKWILA DEG 1 9 2007 PEHMIT CENTER • • • associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415 - 362 -5857 FX: 415-362-5044 B ARE E SCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO. TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND/OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SEf H z U a) C C) _C 0 C!) 0 I PROJ. NO.: PM: JC: CHECKED: 7.112 A.M. A.C. SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: LIGHTING PLAN E -3 r F 1 2 3 4 I 5 6 7 8 9 GUTTER (SEE E -2) SPECIFIC NOTES . UNISEX STROOM STOCKROOM illl / // %z % i/ // // I/ //II// i/// / / / /// // // / / / /// .� LA -20 _ — LA -16,18 POWER PLAN LA -31,33 LA -27 LA -14 WP J -BOX FOR CONNECTION TO REMOTE WATER METER. VERIFY EXACT LOCATIO AND REQUIREMENTS WITH PLUMBING CONTRACTOR. SCALE: 1/4"=V-0" TELEPHONE BACKBOARD. SEE SHEET E -5. 480V MAIN DISCONNECT SWITCH. SEE DWG. E -2 SINGLE LINE DIAGRAM. FOR CONNECTION TO SIGN. VERIFY EXACT LOCATION AND REQUIREMENTS WITH SIGN CONTRACTOR. PROVIDE 120V, 20A, 1P DISCONNECT SWITCH MOUNT NEXT TO J -BOX AS RERQUIRED. FOR CONNECTION TO INSTA -HOT WATER HEATER. VERIFY EXACT LOCATION WITH PLUMBING CONTRACTOR. PROVIDE 240V, 20A, 2P DISCONNECT SWITCH AS RERQUIRED. PROVIDE 120V, 20A CEILING MOUNTED SHOW WINDOW RECEPTACLE. VERIFY EXACT LOCATION AT THE SITE. PROVIDE 120V, 20A CEILING MOUNTED RECEPTACLE FOR INSTALLATION OF FUTURE SECURITY DEVICE. VERIFY EXACT LOCATION WITH SECURITY SYSTEM CONTRACTOR. VERIFY EXACT LOCATION OF 120V, 20A PLASMA TV DUPLEX RECEPTACLE. AND AUDIO VISUAL OUTLETS WITH ARCHITECT. VERIFY ALL REQUIREMENTS WITH COMMUNICATION CONTRACTOR PRIOR TO ANY WORK. FOR CONNECTION TO DOOR HOLD OPEN AT ENTRY. VERIFY ALL REQUIREMENTS PRIOR TO INSTALLATION OF OUTLET. 27 31 SALES 31 GENERAL NOTES J- K- FIRE ALARM SYSTEM: = = 27 27 LA- 21,23,25 LA--- 8 4I► 31 1 G-- PROVIDE GROUND WIRE WITH ALL HOMERUNS & BRANCH WIRING. H- 7 A- VERIFY EXACT LOCATION OF ALL OUTLETS WITH BARE ESSENTUAL SITE CONSTRUCTION MANAGER PRIOR TO ANY WORK. B- ALL DEVICES, LIGHTING FIXTURES, SWITCHES, RECEPTACLES, ETC. SHALL BE NEW AND U.L. LISTED FOR INTENDED USE. C- STAGGER ALL BACK -TO -BACK OUTLETS (1) STUD SPACE . D- ANY CIRCUIT FEEDING ONLY ONE RECEPTACLE SHALL HAVE 120V, 20A DUPLEX RECEPTACLE, U.O.N. E- ALL POWER, TELE /DATA, TV OR OTHER OUTLETS SHOWN SIDE -BY -SIDE, SHALL BE MOUNTED A 1 1/2" SEPARATION, (OR A STUD WIDTH), BETWEEN THE BOXES. (FLOOR OUTLETS SIMILAR). MOUNT ALL OUTLETS AT +18" A.F.F., U.O.N. F- COLOR OF RECEPTACLES, SWITCHES & COVERPLATES SHALL BE WHITE. U.O.N. REVIEWED FOR CODE COMPLIANCE E NFPA JAN - 2 2000 City Of Tukwila BUILDING DN SION ALTERATIONS TO FIRE -LIFE SAFETY SYSTEM SHALL BE DONE BY A LANDLORD APPROVED VENDOR UNDER THIS CONTRACT. THE FIRE ALARM CONTRACTOR SHALL PROVIDE DETAILED DRAWINGS SHOWING ALL REQUIRED DEVICES (SUCH AS PULL STATION, STROBE, HORN, SMOKE DETECTOR, DUCT DETECTOR, SPEAKER, MAGNETIC HOLD OPENS, TRANSPONDER, ETC), AND THEIR CONNECTION TO EXISTING SYSTEM AND OBTAIN APPROVAL FROM BUILDING DEPARTMENT PRIOR TO ANY WORK. ALL NEW CONNECTIONS TO EXISTING SYSTEM SHALL BE PER NFPA 72 AND MEET LOCAL FIRE MARSHAL REQUIREMENTS. VERIFY ALL PRIOR TO INSTALLATION OF DEVICES. I- INFORMATION GIVEN ON THE DRAWINGS REGARDING EXISTING INSTALLATIONS OR CONDITIONS HAS BEEN OBTAINED FROM THE BEST SOURCES AVAILABLE, BUT CAN NOT BE GUARANTEED ACCURATE IN ALL RESPECTS. VERIFY ALL SUCH INFORMATION BEFORE PROCEEDING WITH ANY NEW WORK THAT MAY BE AFFECTED. INCLUDE AS A PART OF THE CONTRACT ALL WORK REQUIRED TO PRODUCE THE INDICATED RESULT. RELOCATE AND /OR RECONNECT EXISTING CIRCUITS WHERE CONTINUITY HAS BEEN AFFECTED OR AS MAY BE REQUIRED TO PROVIDE FOR NEW CONSTRUCTION. PROVIDE CONDUIT FOR THERMOSTAT, VAV BOX AND DUCT DETECTORS AS REQUIRED. E CITY RECEIVED TUKWILA LO1 DEC 19 2007 PEHMi i CEN i ER • • • associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415 - 362 - 5857 FX: 415 -362 -5044 B ARE E SCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO. TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS, ANY REPRODUCTION, MODIFICATION. DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION DF THEN WITHOUT PRIDR WRITTEN CONSENT IS STRICTLY PROHIBITED. REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET 4= H z U ^ L W -1-r+ C › co 0 co op co C\I cri 00 C 0- CO VJ 4- ^ � W U W a O Co a) Z 0 PROJ. NO.: PM: JC: CHECKED: 7.112 A.M. A.G. SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: POWER PLAN E -4 NUMBER USE USE TBD VOICE LINE 1 MANAGER'S DESK TBD ROLLOVER VOICE 2 MANAGER'S DESK TBD MODEM 1 T.T.B. CASHWRAP, P05 # 1, 2 & 3 TBD MODEM 2 T.T.B. TBD FAX T.T.B. & CASHWRAP Kit% ' /iz#/' 4 i t i I 0 A Ii � • \ \1\, Art 4 r MOM 14E 1 / H.C. UNISEX 111, �I lj � II II r %� I / / // !! /.(/ // / / / // / /// /! // / / / r /// / / / / / /// / / / / % % /I / / / / ///! % %/ //� STOCKROOM 6 FA II t. it i ��} 1/ % % WALL MOUNTED DEMARC 110 PUNCH DOWN BLOCK. (LABLE EACH CONNECTION) 1"C. TO LANDLORD C TELEPHONE CLOSET WALL MOUNTED DATA 24 PORT PATCH PANEL. (LABLE EACH CONNECTION) I CONFIRM EXACT LOCATION OF SERVER EQUIP. WITH ARCHIT. PRIOR TO ROUGH -IN SIGNAL PLAN 5 - - I I I I I I I I I LOCATE WITHIN MILLWORK COORD. EXACT LOCATION W/ ARCHITECTURAL ELEVATIONS AND MILLWORK CONTRACTOR PRIOR TO ROUGH -IN. 0 N.T.S. TELEPHONE BACKBOARD 45(4'X3/4" THICK FIRE RATED PLYWOOD TO TELE /DATA JACKS (CASH WRAP, ETC.) 4 -PLEX RECEPTACLE TELEPHONE BACKBOARD (T.T.B.) DETAIL SALES SCALE: 1/4"=V-0" CABLE DROP ONLY. LOCATED ABOVE CEILING AV (1) CONTACT: DEBORAH TAYLOR @ 415 -489 -5539 IF YOU HAVE ANY QUESTIONS REGARDING THIS DATA PLAN DATA JACK SPECIFICATIONS: 1. T.T.B. - NETWORK PATCH PANEL (36" FROM FLOOR ON WALL ABOVE "BELKIN BOX" - BIG BLACK BOX DELIVERED TO STORE ADDRESSED TO DEBORAH) 2. CASHWRAP - (2) LIVE DATA JACKS (LINKED BACK TO PATCH PANEL # 1). 3. POS # 1 - (2) LIVE DATA JACKS (LINKED BACK TO PATCH PANEL # 1). 4. POS # 2 - (2) LIVE DATA JACKS (LINKED BACK TO PATCH PANEL # 1). 5. PDS # 3 - (2) LIVE DATA JACKS (LINKED BACK TO PATCH PANEL # 1). 6. DEVICE ABOVE ENTERY - (2) LIVE DATA JACKS 7. MANAGER'S DESK - (1) LIVE DATA JACKS AND (1) ANALOG JACK FOR FAX UNE (TO DEMARC). TELECOMMUNICATIONS SPECIFICATIONS PURPOSE - THIS DOCUMENT ESTABUSHES THE STANDARDS AND DEFINES THE TECHINICAL SPECIFICATIONS FOR COMMUNICATION WIRING. CONTRACTORS - THIS DOCUMENT SETS THE MINIMUM COMPLIANCE REQUIREMENTS FOR CABLING INSTALLERS. WIRING SUBCOMPONENTS - THE FOLLOWING WIRING SUBCOMPONENTS ARE COVERED UNDER THIS DOCUMENT. HORIZONTAL CATEGORY 5 (UTP) CABLES RGB AND COAXIAL CABLES WORK STATION JACKS LABEUNG DESIGN STANDARDS - DESIGN STANDARD FOR TEH FOLLOWING AREAS: EXTENDED DEMARC (TELCO MULTI PAIR FROM THE BUILDING MAIN POINT OF ENTRY (MPOE) TO THE EQUIPMENT ROOM) WALL MOUNTED EQUIPMENT LAYOUT. WIRING CONTRACTOR COMPLIANCE - ANY CONTRACTOR PERFORMING TELECOMMUNICATIONS WIRING WORK SHALL BE A CERTIFIED INSTALLER. THE CONTRACTOR SHALL HAVE AT LEAST ONE PERSON ON HIS /HER STAFF THAT IS BICSI RCDD CERTIFIED. ALL WIRING CONTRACTORS MUST AGREE TO COMPLY WITH ALL LOCAL, STATE, AND FEDERAL LAWS REGARDING BUILDING CODES, SAFETY CODES, ENVIROMENTAL CODES, NATIONAL ELECTRICAL CODE AND ANY OTHER APPLICABLE LAWS WITHIN THE JURISDICTION OF THE PROJECT. THE CONTRACTOR IS RESPONSIBLE FOR INSURING THAT ALL UTP CABLES APPLICABLE GOVERNING BODY FLAME RETARDANT SPECIFICATIONS. THE CONTRACTOR MUST BE UCENSED IN THE SUBJECT STATE INSTALLATION OF "LOW VOLTAGE WIRING INSTALLATIONS ", AS REQUIRED BY STATE LAWS AND REGULATIONS. ALL WIRING CONTRACTORS SHALL EXTEND A MINIMUM OF ONE (1) FULL YEAR PARTS AND LABOR WARRANTY ON THE TELECOMMUNICATIONS WIRING WORK PERFORMED. ANY TRAVEL COSTS ASSOCIATED WITH THE WARRANTY SHALL BE THE RESPONSIBLITY OF THE CONTRACTOR AND SHALL NOT BE BILLED BACK TO THE OWNER. DAMAGE TO PARTS AND EQUIPMENT RESULTING WARRANTY 1S IN ADDITION TO THE STANDARD MULTI -YEAR WARRANTY PROVIDED UNDER THE UNIPRISE STRUCTURE WIRING SYSTEMS. THE CONTRACTOR MUST PROVIDE DOCUMENTATION IDENTIFYING WIRING INSTALLATIONS WARRANTY PROVISIONING FOR THE WARRANTY UFE OF THE WIRING INSTALLATIONS. THIS DOCUMENTATION MUST SPECIFICALLY IDENTIFY WHO (SUBCONTRACTOR, UNIPRISE, ETC.) WILL SUPPORT THE WIRING INSTALLATIONS WARRANTY IN THE EVENT THAT THE CONTRACTOR SHOULD CEASE BUSINESS OPERATIONS DURING THE WARRANTY PERIOD THE DOCUMENTATION SHOULD PROVIDE DETAILS ON THE TYPE OF CABLE END -TO -END WARRANTY THAT IS BEING OFFERED, I.E. "CHANNEL LINK WARRANTY". FOR NEW INSTALLATIONS, THE CONTRACTOR MUST SUPPLY AS -BUILT DRAWINGS. THE CONTRACTOR MUST HAVE ALL LEGAL AGREEMENTS IN PLACE, INCLUDING BUT NOT LIMITED TO, STANDARD CONTRACTOR AGREEMENT, CONFIDENTIALITY AND NON - DISCLOSURE AGREEMENT, AND PROOF OF INSURANCE CABLING STANDARD - A CERTIFIED CABLE SOLUTION CARRYING A MANUFACTURER'S WARRANTY IS TO BE INSTAI I FD. MANUFACTURE'S SPECIFICATIONS MEET ANSI /TIA /EIA 568 -B 2.1 STANDARDS. WIRING SUBCOMPONENTS - ALL HORIZONTAL CABLING SHOULD QUALIFY TO BE PART OF THE MANUFACTURER'S CERTIFIED SOLUTION. FROM THE SERVER ROOM. ALL HORIZONTAL CABLING SHOULD BE ROUTED IN A MAIN BUNDLE AND ALWAYS MAKE 90 DEGREE TURNS (NO DIAGONAL ROUTES). THECABLING IS TO BE SUPPORTED SUFFICIENTLY TO MEET LOCAL CODES. ALL VOICE HORIZONTAL CABLING IS TO BE WHITE AND ALL DATA IS TO BE BLUE. LABEUNG - ALL WORKSTATION JACKS AND CABLES ARE TO BE LABELED WITH THE DESIGNATED OFFICE, ROOM OR CUBUCLE LOCATION NUMBER,. IN ADDMON, A,B IS TO BE USED FOR VOICE AND C,D FOR DATA, THESE SAME IDENTIFYING LABELS ARE TO BE USED ON THE ORIGINATING ENDS. (DC. OFFICE 101 WOULD HAVE 101 -A, 101 -B, 101 -C AND 101 -0) THESE LABELS SHOULD APPEAR ON THE PATCH PANEL, EACH END OF THE CABLE AND ON THE WORKSTATION JACK. CASHWRAPS - STANDARD CASHWRAP - 3 EACH, CAT 5 UTP CABLES TO EACH WORKSTATION (1 CABLE FOR VOICE AND 2 CABLES FOR DATA) SINGLE UNE WALL - TELEPHONE -- 1 EACH, CAT 5 UTP WHITE CABLE TO EACH TELEPHONE JACK. THE FIRE RATING OF ALL CABLES MUST COMPLY WITH ALL APPUCABLE LOCAL, STATE AND FEDERAL BUILDING CODE REQUIREMENTS. SINGLE STATION TELEPHONE JACKS WILL UTILIZE A SINGLE RJ -45 JACK TO TERMINATE THE 4 PAIR CAT. 5 CABLE. ALL FOUR PAIRS OF THE CABLE MUST BE TERMINATED ON THE STATION JACK IN ORDER TO MAINTAIN THE ANSI/11A /EIA - 568 - STANDARD. DESIGN STANDARDS - EXTENDED DEMARC THE EXTENDED DEMARC SHOULD BE A MINIMUM OF 50 PAIR, MEETING LOCAL BUILDING CODES FOR FIRE SAFETY. THE CABLE SHOULD ORIGINATE ON A 66 BLOCK IN THE BUILDING MPOE AND TERMINATE ON A 110 STYLE BLOCK IN THE TELEPHONE BACKBOARD. SPECIFIC NOTES -- SIGNAL 1 4 pi I 4' X 4' X 3/4" THICK FIRE RETARDANT PLYWOOD TELE. BACKBOARD. PAINT TO MATCH ADJACENT FINISH. RUN 1"C. TELEPHONE WITH PULL STRING TO EXISTING BUILDING TELEPHONE BACKBOARD. VERIFY REQUIRED CONDUIT SIZE WITH COMMUNICATION CONTRACTOR. PROVIDE 3/4 "C, 1#6 GND., CONNECT TO BLDG. GND., STEEL STRUCTURE AND BOND TO MAIN C.W. PIPE. PROVIDE TV OUTLET WITH COAX CABLING FOR PLASMA TV UNIT (IN NICHE) BACK TO TELEPHONE BACKBOARD. COORDINATE LOCATION AND WIRING REQUIREMENTS PER OWNER'S /ARCHITECT'S VENDOR. PROVIDE 1 "C. FOR TELE. /DATA CABLING WITH THREE CAT. 5 CABLES AND ROUTE BACK TO PATCH PANEL. 5 6 7 PROVIDE 1 "C. WITH ONE CAT. 5 BACK TO PATCH PANEL AT T.T.B. STUB CONDUIT TO ABOVE CLG. NEAR CENTER DOORWAY AND LEAVE 10' CABLE SERVICE LOOP FOR FUTURE TRAFFIC COUNTER. STORE USES 2 LINE PHONES- ONE CORDDED PHONE IN THE BACK OFFICE AND ONE REMOTE UNIT. -MAIN VOICE LINE AND ROLLOVER LINE NEEDS TO BE TERMINATED ON "2 LINE JACK" AT THIS LOCATION. - REMOTE EXTENSION UNIT AT CASH WRAP (NO JACK NEEDED). USE "66" TYPE BLOCK PANEL FOR ALL PHONE TERMINATIONS AT MAIN DEMARC AT THIS LOCATION. USE 12 PORT NETWORK PATCH PANEL FOR ALL DATA /VOICE TERMINATIONS AT THIS NOT WALL PLATES. 1.0 t LOCATION - RECEIVED CITY OF TUKWILA GAL, 1 9 2007 PERMIT CENTER ,............r,, ...... A T . nAt 140„ \ Vii L_41/4.S_ 0 assoc • ARCHITECTURE • INTERIORS • PLANNING 274719th STREET SAN FRANCISCO, CA 94110 PH: 415 -362 -5857 FX: 415 -362 -5044 BARE ESCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO. TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION. MODIRCATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET 46 AP .0 4 s C1 s' `Ip #04, x., v 14786 c %�� } . - w � / I Souti iter Park 98188 -c g Count PROJ. NO.: 7.112 PM: A.M. „IC: A.C. CHECKED: SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: SIGNAL PLAN -5 Kit% ' /iz#/' 4 i t i I 0 A Ii � • \ \1\, Art 4 r MOM 14E 1 / H.C. UNISEX 111, �I lj � II II r %� I / / // !! /.(/ // / / / // / /// /! // / / / r /// / / / / / /// / / / / % % /I / / / / ///! % %/ //� STOCKROOM 6 FA II t. it i ��} 1/ % % WALL MOUNTED DEMARC 110 PUNCH DOWN BLOCK. (LABLE EACH CONNECTION) 1"C. TO LANDLORD C TELEPHONE CLOSET WALL MOUNTED DATA 24 PORT PATCH PANEL. (LABLE EACH CONNECTION) I CONFIRM EXACT LOCATION OF SERVER EQUIP. WITH ARCHIT. PRIOR TO ROUGH -IN SIGNAL PLAN 5 - - I I I I I I I I I LOCATE WITHIN MILLWORK COORD. EXACT LOCATION W/ ARCHITECTURAL ELEVATIONS AND MILLWORK CONTRACTOR PRIOR TO ROUGH -IN. 0 N.T.S. TELEPHONE BACKBOARD 45(4'X3/4" THICK FIRE RATED PLYWOOD TO TELE /DATA JACKS (CASH WRAP, ETC.) 4 -PLEX RECEPTACLE TELEPHONE BACKBOARD (T.T.B.) DETAIL SALES SCALE: 1/4"=V-0" CABLE DROP ONLY. LOCATED ABOVE CEILING AV (1) CONTACT: DEBORAH TAYLOR @ 415 -489 -5539 IF YOU HAVE ANY QUESTIONS REGARDING THIS DATA PLAN DATA JACK SPECIFICATIONS: 1. T.T.B. - NETWORK PATCH PANEL (36" FROM FLOOR ON WALL ABOVE "BELKIN BOX" - BIG BLACK BOX DELIVERED TO STORE ADDRESSED TO DEBORAH) 2. CASHWRAP - (2) LIVE DATA JACKS (LINKED BACK TO PATCH PANEL # 1). 3. POS # 1 - (2) LIVE DATA JACKS (LINKED BACK TO PATCH PANEL # 1). 4. POS # 2 - (2) LIVE DATA JACKS (LINKED BACK TO PATCH PANEL # 1). 5. PDS # 3 - (2) LIVE DATA JACKS (LINKED BACK TO PATCH PANEL # 1). 6. DEVICE ABOVE ENTERY - (2) LIVE DATA JACKS 7. MANAGER'S DESK - (1) LIVE DATA JACKS AND (1) ANALOG JACK FOR FAX UNE (TO DEMARC). TELECOMMUNICATIONS SPECIFICATIONS PURPOSE - THIS DOCUMENT ESTABUSHES THE STANDARDS AND DEFINES THE TECHINICAL SPECIFICATIONS FOR COMMUNICATION WIRING. CONTRACTORS - THIS DOCUMENT SETS THE MINIMUM COMPLIANCE REQUIREMENTS FOR CABLING INSTALLERS. WIRING SUBCOMPONENTS - THE FOLLOWING WIRING SUBCOMPONENTS ARE COVERED UNDER THIS DOCUMENT. HORIZONTAL CATEGORY 5 (UTP) CABLES RGB AND COAXIAL CABLES WORK STATION JACKS LABEUNG DESIGN STANDARDS - DESIGN STANDARD FOR TEH FOLLOWING AREAS: EXTENDED DEMARC (TELCO MULTI PAIR FROM THE BUILDING MAIN POINT OF ENTRY (MPOE) TO THE EQUIPMENT ROOM) WALL MOUNTED EQUIPMENT LAYOUT. WIRING CONTRACTOR COMPLIANCE - ANY CONTRACTOR PERFORMING TELECOMMUNICATIONS WIRING WORK SHALL BE A CERTIFIED INSTALLER. THE CONTRACTOR SHALL HAVE AT LEAST ONE PERSON ON HIS /HER STAFF THAT IS BICSI RCDD CERTIFIED. ALL WIRING CONTRACTORS MUST AGREE TO COMPLY WITH ALL LOCAL, STATE, AND FEDERAL LAWS REGARDING BUILDING CODES, SAFETY CODES, ENVIROMENTAL CODES, NATIONAL ELECTRICAL CODE AND ANY OTHER APPLICABLE LAWS WITHIN THE JURISDICTION OF THE PROJECT. THE CONTRACTOR IS RESPONSIBLE FOR INSURING THAT ALL UTP CABLES APPLICABLE GOVERNING BODY FLAME RETARDANT SPECIFICATIONS. THE CONTRACTOR MUST BE UCENSED IN THE SUBJECT STATE INSTALLATION OF "LOW VOLTAGE WIRING INSTALLATIONS ", AS REQUIRED BY STATE LAWS AND REGULATIONS. ALL WIRING CONTRACTORS SHALL EXTEND A MINIMUM OF ONE (1) FULL YEAR PARTS AND LABOR WARRANTY ON THE TELECOMMUNICATIONS WIRING WORK PERFORMED. ANY TRAVEL COSTS ASSOCIATED WITH THE WARRANTY SHALL BE THE RESPONSIBLITY OF THE CONTRACTOR AND SHALL NOT BE BILLED BACK TO THE OWNER. DAMAGE TO PARTS AND EQUIPMENT RESULTING WARRANTY 1S IN ADDITION TO THE STANDARD MULTI -YEAR WARRANTY PROVIDED UNDER THE UNIPRISE STRUCTURE WIRING SYSTEMS. THE CONTRACTOR MUST PROVIDE DOCUMENTATION IDENTIFYING WIRING INSTALLATIONS WARRANTY PROVISIONING FOR THE WARRANTY UFE OF THE WIRING INSTALLATIONS. THIS DOCUMENTATION MUST SPECIFICALLY IDENTIFY WHO (SUBCONTRACTOR, UNIPRISE, ETC.) WILL SUPPORT THE WIRING INSTALLATIONS WARRANTY IN THE EVENT THAT THE CONTRACTOR SHOULD CEASE BUSINESS OPERATIONS DURING THE WARRANTY PERIOD THE DOCUMENTATION SHOULD PROVIDE DETAILS ON THE TYPE OF CABLE END -TO -END WARRANTY THAT IS BEING OFFERED, I.E. "CHANNEL LINK WARRANTY". FOR NEW INSTALLATIONS, THE CONTRACTOR MUST SUPPLY AS -BUILT DRAWINGS. THE CONTRACTOR MUST HAVE ALL LEGAL AGREEMENTS IN PLACE, INCLUDING BUT NOT LIMITED TO, STANDARD CONTRACTOR AGREEMENT, CONFIDENTIALITY AND NON - DISCLOSURE AGREEMENT, AND PROOF OF INSURANCE CABLING STANDARD - A CERTIFIED CABLE SOLUTION CARRYING A MANUFACTURER'S WARRANTY IS TO BE INSTAI I FD. MANUFACTURE'S SPECIFICATIONS MEET ANSI /TIA /EIA 568 -B 2.1 STANDARDS. WIRING SUBCOMPONENTS - ALL HORIZONTAL CABLING SHOULD QUALIFY TO BE PART OF THE MANUFACTURER'S CERTIFIED SOLUTION. FROM THE SERVER ROOM. ALL HORIZONTAL CABLING SHOULD BE ROUTED IN A MAIN BUNDLE AND ALWAYS MAKE 90 DEGREE TURNS (NO DIAGONAL ROUTES). THECABLING IS TO BE SUPPORTED SUFFICIENTLY TO MEET LOCAL CODES. ALL VOICE HORIZONTAL CABLING IS TO BE WHITE AND ALL DATA IS TO BE BLUE. LABEUNG - ALL WORKSTATION JACKS AND CABLES ARE TO BE LABELED WITH THE DESIGNATED OFFICE, ROOM OR CUBUCLE LOCATION NUMBER,. IN ADDMON, A,B IS TO BE USED FOR VOICE AND C,D FOR DATA, THESE SAME IDENTIFYING LABELS ARE TO BE USED ON THE ORIGINATING ENDS. (DC. OFFICE 101 WOULD HAVE 101 -A, 101 -B, 101 -C AND 101 -0) THESE LABELS SHOULD APPEAR ON THE PATCH PANEL, EACH END OF THE CABLE AND ON THE WORKSTATION JACK. CASHWRAPS - STANDARD CASHWRAP - 3 EACH, CAT 5 UTP CABLES TO EACH WORKSTATION (1 CABLE FOR VOICE AND 2 CABLES FOR DATA) SINGLE UNE WALL - TELEPHONE -- 1 EACH, CAT 5 UTP WHITE CABLE TO EACH TELEPHONE JACK. THE FIRE RATING OF ALL CABLES MUST COMPLY WITH ALL APPUCABLE LOCAL, STATE AND FEDERAL BUILDING CODE REQUIREMENTS. SINGLE STATION TELEPHONE JACKS WILL UTILIZE A SINGLE RJ -45 JACK TO TERMINATE THE 4 PAIR CAT. 5 CABLE. ALL FOUR PAIRS OF THE CABLE MUST BE TERMINATED ON THE STATION JACK IN ORDER TO MAINTAIN THE ANSI/11A /EIA - 568 - STANDARD. DESIGN STANDARDS - EXTENDED DEMARC THE EXTENDED DEMARC SHOULD BE A MINIMUM OF 50 PAIR, MEETING LOCAL BUILDING CODES FOR FIRE SAFETY. THE CABLE SHOULD ORIGINATE ON A 66 BLOCK IN THE BUILDING MPOE AND TERMINATE ON A 110 STYLE BLOCK IN THE TELEPHONE BACKBOARD. SPECIFIC NOTES -- SIGNAL 1 4 pi I 4' X 4' X 3/4" THICK FIRE RETARDANT PLYWOOD TELE. BACKBOARD. PAINT TO MATCH ADJACENT FINISH. RUN 1"C. TELEPHONE WITH PULL STRING TO EXISTING BUILDING TELEPHONE BACKBOARD. VERIFY REQUIRED CONDUIT SIZE WITH COMMUNICATION CONTRACTOR. PROVIDE 3/4 "C, 1#6 GND., CONNECT TO BLDG. GND., STEEL STRUCTURE AND BOND TO MAIN C.W. PIPE. PROVIDE TV OUTLET WITH COAX CABLING FOR PLASMA TV UNIT (IN NICHE) BACK TO TELEPHONE BACKBOARD. COORDINATE LOCATION AND WIRING REQUIREMENTS PER OWNER'S /ARCHITECT'S VENDOR. PROVIDE 1 "C. FOR TELE. /DATA CABLING WITH THREE CAT. 5 CABLES AND ROUTE BACK TO PATCH PANEL. 5 6 7 PROVIDE 1 "C. WITH ONE CAT. 5 BACK TO PATCH PANEL AT T.T.B. STUB CONDUIT TO ABOVE CLG. NEAR CENTER DOORWAY AND LEAVE 10' CABLE SERVICE LOOP FOR FUTURE TRAFFIC COUNTER. STORE USES 2 LINE PHONES- ONE CORDDED PHONE IN THE BACK OFFICE AND ONE REMOTE UNIT. -MAIN VOICE LINE AND ROLLOVER LINE NEEDS TO BE TERMINATED ON "2 LINE JACK" AT THIS LOCATION. - REMOTE EXTENSION UNIT AT CASH WRAP (NO JACK NEEDED). USE "66" TYPE BLOCK PANEL FOR ALL PHONE TERMINATIONS AT MAIN DEMARC AT THIS LOCATION. USE 12 PORT NETWORK PATCH PANEL FOR ALL DATA /VOICE TERMINATIONS AT THIS NOT WALL PLATES. 1.0 t LOCATION - RECEIVED CITY OF TUKWILA GAL, 1 9 2007 PERMIT CENTER