HomeMy WebLinkAboutPermit EL07-800 - WESTFIELD SOUTHCENTER MALL - LIMITED TOOLIMITED TOO 1046 SOUTHCENTER MALL ELO7-800 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 1046 SOUTHCENTER MALL TUKW LIMITED TOO 1046 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA SARAH NIELSEN 1120 E 80 ST, STE 211 , BLOOMINGTON MN Contractor: Name: STATIC ELECTRIC INC Address: PO BOX 972 , GRAHAM WA Contractor License No: STATIEI951C8 ELECTRICAL PERMIT DESCRIPTION OF WORK: ELECTRICAL FOR TI: NEW RECEPTACLES, JUNCTION BOX, CIRCUITS, PHONE & DATA OUTLETS, CASHWRAP, SWITCHES, AND LIGHTING. Permit Center Authorized Signature: Signature: Print Name: C ✓t e t Vt Surm Permit Number: Issue Date: Permit Expires On: Phone: Phone: 800 541 -0821 Phone: 253 468 -3296 Expiration Date: 02/25/2009 ELOZ -800 05/22/2008 11/18/2008 Value of Electrical: $35,000.00 Fees Collected: $936.00 Type of Fire Protection: SPRINXLERS /AFA National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY C -\I, Date: J ` d-'.' I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of w'k. I ax authorized to sign and obtain this electrical permit. Date: 5 - 2-zr07( This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL07 -800 Printed: 05-22 -2008 Parcel No.: 6364200010 Address: 1046 SOUTHCENTER MALL TUKW Suite No: Tenant: LIMITED TOO 1: ** *ELECTRICAL * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: EL07 -800 Status: ISSUED Applied Date: 12/21/2007 Issue Date: 05/22/2008 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 286 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: doc: Cond -Elec Print Name: tel -e-- r1 Y►.SG r1 Date: S "2 �G EL07 -800 Printed: 05-22 -2008 r CITY OF TUKWIL°' Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.d.tukwila.wa.us Site Address:I 047 .Airlte i-e3 -- � I Tenant Name: L r k Iola Property Owners Name: VAES A Cr Mailing Address: LIGOI WAS k Neyord los p►Y1f1e_W -S CA g6o2s i 1 City State CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Flr►xcr\r1 Ni' ,2-\S Day Telephone: SOd I'4-1 -CR21 Mailing Address: (17() M €17.Yr, Sice Ztt, gatecwlirN(142n, NtN 554-70 City State Zip E -Mail Address: gciecr Reeirterio 1eS _COvr Fax Number: 'i'SZ !SSA - 4g09 ELECTRICAL CONTRACTOR INFORMATION Company Name: T.R . b. Mailing Address: Electrical Permit No > Project No. 1201- 16 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: Ga3t04 Suite Number: 12- Floor: New Tenant: ® Yes ❑ ..No State Zip Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ 3 OOb Scope of Work (please provide detailed information): lS4..w rec..eS'4o.Cs, ;. i(\c*Or troc tacc �tS p rldr∎2 = daeox p► ��ic'ES pxsh LA-)co.p t 9 ,j kd-e.S, [ i C.th r9 Will service be altered? ❑ Yes 1111 No Type of Use: MerceorA l Adding more than 50 amps? ❑ Yes ® No Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel • Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Pro Served by: Puget Sound Energy Seattle City Light H :\Applications\Fonns-Applications On Line\4 -2007 - Electrical Permit Application.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits.. $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: I Date Application Accepted: Mailing Address: ( t■ C g ettl 'P` s 1U 12-174 1 H :lApplications\Forms-Applications On Line \4 -2007 - Electrical Pennit Application.doc bh MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: Day Telephone: 1 $1 P�� 4444 City State gall Zip Date Application Expires: 71 to, Staff Initials: �. — 1 Page 2 of 2 Receipt No.: R08 -01778 Initials: WER User ID: 1655 Payee: STATIC ELECTRIC ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL07 -800 Address: 1046 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 12/21/2007 Applicant: LIMITED TOO Issue Date: TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3714 772.00 Account Code Current Pmts 000.322.101.00.0 772.00 Total: $772.00 Payment Amount: 5772.00 Payment Date: 05/22/2008 10:58 AM Balance: $0.00 2761 05/22 9711 TOTAL 1568.00 doc: Receiot -06 Printed: 05-22 -2008 Receipt No.: R07 -02843 Initials: JEM User ID: 1165 Payee: ELDER -JONES TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL07 -800 Address: 1046 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 12/21/2007 Applicant: LIMITED TOO Issue Date: Amount Payment Check 50591 164.00 Account Code Current Pmts 000.345.832.00.0 164.00 Total: $164.00 Payment Amount: $164.00 Payment Date: 12/21/2007 02:49 PM Balance: 3656.00 6394 12/24 9710 TOTAL 164.00 rlor.• RPCPint -06 Printer: 12 -21 -2007 Project: l UPI OV Type of Inspection: 21o° DO v Address: / 1144/ Date Called: r-- Special Instructions: Date Wanted: 24 7/ 6.sa. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION l 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 9.K (Inspector: do( (Date: 07/2,f/04 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project: � � � d0 � Type of Inspection: o 0 Address: / Dq to tikui Date Called: �-- Special Instructions: Date Wanted: f /�� !�(/ (ilk Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION Za- I` (206)431 -3670 6300 Southcenter Blvd., #100, Tukwila, WA 98188 EJ Approved per applicable codes. Corrections required prior to approval. COMMENTS: STacid srivi--r 6 sly- (4m-1 atc,terkuks A 'Inspector: &Ai INSPECTION RECORD Retain a copy with permit ELo'7 \Zoo PERMIT NO. (Date: J 23 ' JJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project: �'� I�� Type of Inspection: 7D03 f i Address: /0 ! 11 T+'v Date Called: Special Instructions: Date Wanted: /6 p: m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPE • ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. Corrections required prior to approval. COMMENTS: ?Pc OK- 114 /U 44 6:. PERMIT NO. P- (206)431-3670 'Inspector: c d; - 81 ,/ 'Date: 0 Or 40 � V � El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project: L M, ' 5/ -Go of Inspection: n � o J`' Address: Date Called: Special Instructions: etST &O01( Date Wanted: 6/15 6Ine p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IP 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. 11 Corrections required prior to approval. COMMENTS: ?A- b.K C‘51'2001 WAUiS /u' c.J! &Iwo (Date: N t� O� Uco ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Inspector: (Receipt No.: 'Date: Project: Type of Inspection: Address: j1 �rit,77/4A417 / *9t Date Called: Special Instructions: Date Wanted: �� {,� p.m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit [12 V PERMIT N O. CITY OF TUKWILA BUILDING DIVISION 1 4 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 roved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Pig - Of& - /91// Insp or: Date: ff‘il I b,' r $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: COMMENTS: Type of Inspection: 399117C, Date Called: V C- Special Instructions: Oi -- c04 tc WAv ksJ t) liAp>J S t�siP F, W o1 oif?I 15 (A /M2- PJom5 . ► $(c.a* Me- sy hMrJ 2) clet44Difsik tt toix cfl (cmo,,l 9-6 3t Accosi cst.E Project: r- L -rh sTt9 Ida Type of Inspection: 399117C, Date Called: Address: / / 1144A/ Special Instructions: Date Wanted: a .m. S/30 p.m. Requester: Phone No: aoi i7co INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION f- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. ['Corrections required prior to approval. Inspector: &-ri Date: 05/30A $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: !Date: Project: LI w Too Type of Inspection: ^„ �j700.2..._ Address: /01/6 t Date Called: Special Instructions: Date Wanted: / �J30 ((( a.m. p.m. Requester: ■ Phone No: INSPECTION NO. Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 14; 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. COMMENTS: go> 51L. ?a° f ‘ti,5 Kaoittep our o{ 51_ Inspector: /r, 'Date: o S 3a o El $60.00 REII4SPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project: lim/?ib o Type of Inspection: /�' vfr lrJ� Addres : /0V . 5� //itt Date Called: Special Instructions: Date Wanted: rh 3 a m m. Requester: Phone No: 1 INSPECTION NO. Retain a copy with ► 7 - 9001 INSPECTION RECORD PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 206)431- COMMENTS: -- vv,* (s - Inspe proved per applicable codes. 12 Corrections required prior to approval. /dG dr/ 0mm Date /J/ /7 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project Info Project Address Limited Too - Southcenter Date 3/3/2008 633 Southcenter For Building Department Use Seattle, WA 98188 Applicant Name: sax Consultants Applicant Address: 171 Charring Cross Drive South Suite 1B Applicant Phone: Westerville, OH 43081 614 -882 -1199 2006 Washington State Nonresidential Energy Code Compliance Fonns 2006 Washington State Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM REVISION N0:? FILECOPY ELo18oO FILE COPY ! S?.,rIN A J C:7071 end om!ssic REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC APR - 2 2008 City Of Tukwila B LDING DIVL I, N Revised July 2007 RECEIVED MAR 0 7 2008 PERMIT CENTEE Project Info Project Address Limited Too - Southcenter Date 3/3/2008 633 Southcenter For Building Department Use Seattle, WA 98188 Applicant Name: HBK Consultants Applicant Address: 171 Charring Cross Drive South Suite 18 Applicant Phone: Westerville, OH 43081 614 -882 -1199 Project Description ❑ Plans Induded requirements. ❑ New Building ❑ Addition ' Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces dearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) Occupancy Description Allowed Watts per ft Area in ft Allowed x Area B Retail 1.50 3277.0 4915.5 C Merchandise Display 1.50 3085.0 4627.5 N Stockroom /Office 1.00 579.0 579.0 -- From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 10122.0 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed B Recessed Downlight 23 52.0 1196.0 C Fitting Room Mono -Point 7 50.0 350.0 N Recessed Dovnlight 1 225.0 225.0 2 x 2 Recessed Fluorescent 26 71.0 1846.0 1 x 4 Fluorescent Strip 21 38.0 798.0 Track Track 114 50.0 5700.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 10115.0 Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Maximum Allowed Lighting Wattage Provosed Lighting Wattage 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturers listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) " 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations' 1.0 Cafeterias, fast food establishments', restaurants/bars 1.3 Post office 1.1 Dormitory 1.0 Retail' retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia", assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 HoteVmotel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference/exhibition hall'` 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only` Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers 0 Other Qualification Checklist Note: If occupancy type is "Other and fixture answer is checked, the number of fixtures in the space is not limited by Code. Cleary indicate these spaces on plans. if not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elect tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. 2006 Washington State Nonresidential Energy Code Compliance Forms TABLE 15 -1 Unit Lighting Power Allowance (LPA 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) LTG -INT Revised July 2007 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w/ft may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w/ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Tradable Locations Description Allowed Watts per ft or per If Area (ft perimeter (If) or # of items Allowed Watts x ft (or x If) Seattle, WA 98188 Name: FMK Consultant. Appl. Name 171 Charring Cross Drive South Suite 1B Appl. Phone yresterviile, OR 43081 614- 882 -1199 Project Description ❑ New ❑ Addition ❑ Alteration ❑ Plans Induded Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy> 60 lumens/W ❑ Controlled by motion Sensor Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new. installed wattage not increased. & soace use not changed. Non - Tradable Locations Description Allowed Watts per ft or per If Area (ft perimeter (If) or # of items Allowed Watts x ft (or x If) Seattle, WA 98188 Name: FMK Consultant. Appl. Name 171 Charring Cross Drive South Suite 1B Appl. Phone yresterviile, OR 43081 614- 882 -1199 Project Description ❑ New ❑ Addition ❑ Alteration ❑ Plans Induded Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy> 60 lumens/W ❑ Controlled by motion Sensor Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new. installed wattage not increased. & soace use not changed. Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Seattle, WA 98188 Name: FMK Consultant. Appl. Name 171 Charring Cross Drive South Suite 1B Appl. Phone yresterviile, OR 43081 614- 882 -1199 Project Description ❑ New ❑ Addition ❑ Alteration ❑ Plans Induded Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy> 60 lumens/W ❑ Controlled by motion Sensor Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new. installed wattage not increased. & soace use not changed. Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Seattle, WA 98188 Name: FMK Consultant. Appl. Name 171 Charring Cross Drive South Suite 1B Appl. Phone yresterviile, OR 43081 614- 882 -1199 Project Description ❑ New ❑ Addition ❑ Alteration ❑ Plans Induded Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy> 60 lumens/W ❑ Controlled by motion Sensor Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new. installed wattage not increased. & soace use not changed. Project Info Proj Address Limited Too - Southcenter Date 3/3/2008 633 Southcenter For Building Department Use Seattle, WA 98188 Name: FMK Consultant. Appl. Name 171 Charring Cross Drive South Suite 1B Appl. Phone yresterviile, OR 43081 614- 882 -1199 Project Description ❑ New ❑ Addition ❑ Alteration ❑ Plans Induded Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy> 60 lumens/W ❑ Controlled by motion Sensor Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new. installed wattage not increased. & soace use not changed. Exterior Lighting Summary LTG -EXT 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Tradable Maximum Allowed Lighting Wattage Tradable Provosed Lighting Wattage Total Proposed Watts may not exceed Total Allowed Watts for Exterior Non - Tradable Maximum Allowed Lighting Wattage Non - Tradable Proposed Lighting Wattage Proposed Watts may not exceed Allowed Watts for Category Total Allowed Watts Revised July 2007 Use mfgr listed maximum input wattage. For fixtures with hard -w'red ballasts only, the default table in the NREC Technical Reference Manual may also be used. Total Proposed Watts Tradable Surfaces (Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded.) Uncovered Parking Areas Parking lots and drives 0.15 W/ft Building Grounds Walkways less than 10 feet wide 1.0 W/linear foot Walkways 10 feet wide or greater Plaza areas Special feature areas 0.2W /ft Stairways 1.0 W/ft Building Entrances and Exits Main entries 30 W/linear foot of door width Other doors 20 W/linear foot of door width Canopies and Overhangs Canopies (free standing and attached and overhangs) 1.25 W/ft Outdoor Sales Open areas (including vehicle sales lots) 0.5 W/ft Street frontage for vehicle sales lots in addition to `open area" allowance 20 W/linear foot Non - Tradable Surfaces (Lighting power density calculations for the following applications can be used only for the specific application and cannot be traded between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in the "Tradable Surfaces" section of this table.) Building Facades 0.2 W/ft for each illuminated wall or surface or 5.0W /linear foot for each illuminated wall or surface length Automated teller machines and night depositories 270 W per location plus 90 W per additional ATM per location Entrances and gatehouse inspection stations at guarded facilities 1.25 W /ft of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces ") Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W/ft f uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces") Material handling and associated storage 0.5 W /ft Drive -up windows at fast food restaurants 400W per drive- through Parking near 24 -hour retail entrances 800 W per main entry 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary (back) LTG-EXT TABLE 15 -2 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS Revised July 2007 2006 Washington State Nonresidential Energy Code Compliance Form Lighting Power Allowance Adjustments LTG -LPA 2006 Washington State Nonresidential Energy Code Compliance Forms Adjusted Lighting Power Allowances (Interior) " From Table 15-1 based on exceptions listed in footnotes Revised July 2007 Project Address I Liarited Too - Southcantar 'Date 3/3/2008 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft Carry the Adjusted LPA to the corresponding "Allowed Watts per ft location on LTG - SUM. Location (floor /room no.) Occupancy Description Allowed Watts per ft Ceiling Height for this room Ceiling Height limit for this exception" Adjusted LPA Watts per ft2 Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Limited Too - Southcenter 'Date 3/3/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations E -2 yes 1513.2 Area controls Maximum limit per switch E -2 no 1513.3 Daylight zone control Schedule with type and features, indicate locations no vertical glazing Indicate vertical glazing on plans no overhead glazing Indicate overhead glazing on plans no 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location no (a) timer w/backup Indicate location no (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations E -2 yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans ED -2 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes I 1514 (Max. watts 'Indicate watts for each exit sign I ED -2 1 LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture ED -2 no 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) n.a. I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I l t TRANSFORMERS (Section 1540) yes I 1540 (Transformers 'Indicate size and efficiency IED_2 1 2006 Washington State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the Individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of tuming off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shalt be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically tuming off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of tuming off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low- light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which tums off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft or 5% of the building footprint for footprints over 100,000 ft whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate In accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class 1 Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP- 1- 2002). 05 -08 -2008 SARAH NIELSEN 1120E 80 ST,STE211 BLOOMINGTON MN 55420 RE: Permit Application No. EL07 -800 1046 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 12/21/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 06/18/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 06/18/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: fer Marshall • vsi t Technician Permit File No. EL07 -800 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 - 431 -3665 D PT RTM�' T /Zf)Pt> Bu • ' g D i ion 1K Public Works TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2-28-02 PLAN REVIEW %ROUT SLIP ACTIVITY NUMBER: EL07 -800 DATE: 03 -07 -08 PROJECT NAME: LIMITED TOO SITE ADDRESS: 1046 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 2 Before Permit Issued APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: Fire Prevention Structural Structural Review Required DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1 Incomplete ❑ Planning Division ❑ Permit Coordinator DUE DATE: 03 -11 -08 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required n REVIEWER'S INITIALS: DATE: DUE DATE: 04 -08 -08 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: C Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: EL07 -800 DATE: 02 -13 -08 PROJECT NAME: LIMITED TOO SITE ADDRESS: 1046 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 BEFORE Permit Issued DEPARTMENTS: B ing isi t-‘4] � uild DiV n Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: kftuv PERMIT COORD COPY, PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 ❑ Permit Coordinator n DUE DATE: 02-19-08 Not Applicable ❑ No further Review Required DATE: DUE DATE: 03-18-08 Approved with Conditions Not Approved (attach comments) n DATE: Planning Division Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: EL07 -800 DATE: 12 -21 -07 PROJECT NAME: LIMITED TOO SITE ADDRESS: 1046 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: V�jj G Build(rt sion Public Works Complete Comments: DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route u Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 HERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete ❑ Planning Division Permit Coordinator DUE DATE: 12-27 -07 Not Applicable E No further Review Required DATE: DUE DATE: 01-24-08 Approved E Approved with Conditions ITf Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: n n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INITIALS z 3 -- 7-08 L)K Summary of Revision: u ` Received by: Summary of Revision: v ; a —c (L I c. I6+1 ‘ e'^`'i ft. io r0,4 kA.,-1-&. -e lAev, y co ge s Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 -t -0° � M Summary of Revision: u ` Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: PROJECT NAME: SITE ADDRESS: \OA (o 50,41Nre,n t( PERMIT NO: E L.D 7 - G Oa ORIGINAL ISSUE DATE: REVISION LOG (please print) (please print) (please print) (please print) (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //w►tinv.ci.tukwilawa.us Revision submittals must be submitted in person at the Permit Center. Revisions wiII not be accepted through the mail, fax, etc. Q / - � Plan Check/Permit Number: / Date: ' 3 - 7 - 0 6 ❑ Response to Incomplete Letter # ® Response to C 'o Letter # 2 Revision # ermit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: LIMITED TOO Project Address: 1046 Southcenter Mali Contact Person: W ` °� � s Phone Number: 614- 9'1 14 41 Summary of Revision: S1% -eet E - Re' 4a i rc&c,k ICrliANs r r I�t wi fIN Q nf/ yy Cook PF. Sheet Number(s): �' a "Cloud" or highlight all areas of revision including date � revs ion n �JII Received at the City of Tukwila Permit Center by: lir Entered in Permits Plus on - 7 ? `O lapplicationslfacrosapplications on linelcevision submittal Created: 8 -13 -2004 Revised: AECENED ry op T1 wvAn MAR 07 2008 PFRMCT rE'NTRR Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.waus Steven M Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: �' t3 OS Plan Check/Permit Number: �l' �$ ❑ Response to Incomplete Letter # ❑ Response to Co ction Letter # ❑ Revision # , * , Permit is Issued 0 Revision requested by a City Building Inspector or Plans Examiner 1- olio RECe Ve FEB 13 1008 � RMI T LENTER Project Address: 4e4 s a/ Ke z /6 Contact Person: S,erc.44( Kt's - -' Phone Number: t g tri j4l 0 024 Summary of Revision: 0 W 1 'L 1 t CM4-- '14'N-P dV P(i Sheet Number(s): 1 E V - I 7t' 2 "Cloud" or highlight all are of revls n i � ncluding a of revision Received at the City of Tukwila Permit Center by: / 1j\A Entered in Permits Plus on a I )3:( appplic ationslforms- applications on linelcevision submittal r„M►owt• rt_rsanna �f l License Information License STATIEI951C8 Licensee Name STATIC ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 602455807 Ind. Ins. Account Id PRESIDENT Business Type CORPORATION Address 1 26026 116TH AVE SE Address 2 City KENT County KING State WA Zip 98030 Phone 2534683296 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 2/25 /2005 Expiration Date 2/25 /2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License JOHNSS *973PH Business Owner Information Name Role Effective Date Expiration Date JOHNSON, SHANE E AGENT 02/28/2005 JOHNSON, SHANE E PRESIDENT 02/28/2005 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Electrical Administrator Information License Name Status JOHNSS*973PH JOHNSON, SHANE ACTIVE I Bond Information 5 r 1 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= STATIEI951 C8 05/22/2008 M1� c91 LEN HBK # 0) z z z CI- i 1 DRAWING NUMBER: Id g a 0 S • i 4 E .0° I r ‘"Cr EXPIRES 6112 > J CC U) G co cc r W � H CD W aW� a W W �!. oU uuz: op Im it Oc+) J THE ENGINEER ASSUMES NO RESPONSIBILITY OR UA9ILRY FOR THE USE OF THESE PLANS FOR ANY PROJECT OTHER THAN SPECIFICALLY AUTHORIZED BY THEM AND SIGNED AND SEALED FOR SUCH SPECIFIC LOCATION IN THE STATE SHOWN ON THE SEAL. THIS WILDING USE IS ONLY APPLICABLE IN AREAS MEETING THE STATED DESIGN CIUTERIA. 07164 1. THE ABBREVIATION T.S.P., WHEREVER IT APPEARS IN THESE ELECTRICAL DRAWINGS, SHALL REFER TO "TWEEN BRANDS STORE PLANNING, INC. ". ANY REFERENCE TO TENANT'S, OR LIMITED TOO OR FURNISHED BY ANY OF THE ABOVE REFERS TO T.S.P.. 2. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. CIRCUITING INDICATED ON PLAN IS PARTIALLY DIAGRAMMATIC FOR CLARITY. CIRCUITING SHALL BE "THRU- WIRING" WHERE AND WHENEVER POSSIBLE. 4. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING RELATED ELECTRICAL EQUIPMENT. 5. ALL RECEPTACLE CIRCUITS UP TO 100' -0" SHALL UTIIZE #12 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS FROM 101' -0" TO 150' -0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS 151' -O" UP TO 250' -0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. CIRCUITS ABOVE 251' •0" SHALL UTILIZE #6 CONDUCTORS MINIMUM. 6. PLACEMENT OF ALL RECEPTACLES IN THE "SALES" AREA SHALL BE INTENTIONAL (I.E. - CENTERED ON COLUMNS, WALL FEATURES OR TIGHT TO CORNERS). IF THE RECEPTACLE IS NOT SHOWN IN A DESIRABLE LOCATION, FIELD VERIFY EXACT PLACEMENT OF RECEPTACLE WITH T.S.P.'S CONSTRUCTION MANAGER PRIOR TO ROUGH -IN. 7. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. 8. WHERE DRYWALL CEILINGS ARE USED IN THE "SALES" AREA, THE ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. FIELD COORDINATE WITH T.S.P. CONSTRUCTION MANAGER PRIOR TO ROUGH-IN TO AVOID ANY CONFLICTS. JUNCTION BOXES ABOVE LAY -IN CEILINGS ARE ACCEPTABLE. 9. EQUIPMENT LABELED "GENERAL ELECTRIC" SHALL BE FURNISHED BY T.S.P. AND INSTALLED BY THE ELECTRICAL CONTRACTOR. REFER TO CODED NOTES, ELECTRICAL RESPONSIBILITY SCHEDULE, PANEL SCHEDULE AND POWER RISER DIAGRAM FOR SPECIFIC EQUIPMENT DESCRIPTION. 10. REFER TO SHEETS ED-1, ED -2 AND ES -1 FOR DETAILS, SCHEDULES AND SPECIFICATIONS. 11. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INQUIRE WITH THE LANDLORD'S REPRESENTATIVE ON ANY FIRE ALARM SYSTEMS IN USE AT THE MALL AT THE TIME OF THE BID. IF THE FIRE ALARM SYSTEM IS NOT ADEQUATELY DESCRIBED ON THE DRAWINGS, THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INFORM THE GENERAL CONTRACTOR AND INCLUDE THE COST AS A SEPARATE LINE ITEM IN THE BID. NO ADDITIONAL MONIES SHALL BE AWARDED FOR TIE -IN REQUIREMENTS TO A LANDLORD'S FIRE ALARM SYSTEM THAT IS IN EXISTENCE AT THE TIME OF THE BID, WITHOUT .t jEPARATE LINE ITEM FOR THE FIRE ALARM SYSTEM AT THE T I L T nF THE I3 I O 12. INSTALL ENGRAVED BAKELITE NAMEPLATE ON SERVICE DISCONNECT SWITCH IN LANDLORD'S SWiTCHGEAR WITH DEMISED PREMISFS' SPACE NUMBER. 13. NO HANGERS, SUPPORTS, JUNCTION BOXES, ETC. SHALL BE ATTACHED TO ROOF DECK. 1O RECEPTACLES AND COVERPLATES DESIGNATED "SF" SHALL BE WHITE IN COLOR, FURNISHED BY T.S.P. AND INSTALLED BY ELECTRICAL CONTRACTOR WHERE SHOWN ON PLANS IN THE UNDERSIDE OF THE STOREFRONT SOFFIT WITH THE 4" SIDE PARALLEL TO THE STOREFRONT GLASS. FIELD VERIFY EXACT LOCATION OF ALL RECEPTACLES WITH T.S.P.'S CONSTRUCTION MANAGER PRIOR TO ROUGH - IN OF RECEPTACLE BOXES. O2 RECEPTACLES AND COVERPLATES SHALL BE IVORY IN COLOR UNLESS NOTED OTHERWISE. RECEPTACLES AND COVERPLATES SHALL BE FURNISHED BY T.S.P. AND INSTALLED BY ELECTRICAL CONTRACTOR. MOUNT ALL RECEPTACLES HORIZONTALLY IN CENTER OF BASEBOARD. FIELD COORDINATE WITH WALL SYSTEM INSTALLER BEFORE WALL SYSTEM INSTALLED TO AVOID CONSTRUCTION DELAYS. FIELD VERIFY EXACT LOCATION OF ALL RECEPTACLES WITH T.S.P.'S CONSTRUCTION MANAGER PRIOR TO ROUGH -IN OF RECEPTACLE BOXES. V RECEPTACLES AND COVERPLATES IN "NON- SALES" SHALL BE WHITE IN COLOR, FURNISHED BY T.S.P. AND INSTALLED BY ELECTRICAL CONTRACTOR. MOUNT ALL RECEPTACLES AT 18" A.F.F. EXCEPT AS NOTED ON FLOOR PLAN. FIELD VERIFY EXACT LOCATION OF ALL RECEPTACLES WITH T.S.P.'S CONSTRUCTION MANAGER PRIOR TO ROUGH - IN OF RECEPTACLE BOXES. TYPICAL OF ALL RECEPTACLES IN "RECEIVING" AND "H C. L ." A A N 5 N O H 1 E 4� INSTALL A DELIVERY BUZZER SYSTEM AT 3 "- 6" A.F.F.. T.S.P. SHALL FURNISH PUSHBUTTONS, TRANSFORMER AND BUZZERS WITH LOUVERED COVERPLATES AND TRANSFORMER MOUNTING PLATE. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NECESSARY JUNCTION BOXES, ONDUIT AND WIRE TO COMPLETELY INSTALL THE DELIVERY BUZZER SYSTEM. POWER GENERAL NOTES 14. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF CEILING - RECESSED SPEAKERS. SPEAKERS SHALL BE INSTALLED INTO CENTER OF SUSPENDED CEILING ACOUSTICAL TILES AND HUNG FROM STRUCTURAL SUPPORT. 15. COORDINATE ALL ROOF PENETRATIONS WITH THE LANDLORD. WRITTEN PERMISSION FROM THE LANDLORD SHALL BE RECEIVED PRIOR TO ANY WORK BEING PERFORMED. ALL ROOF PENETRATIONS TO BE BY LANDLORD'S CONTRACTOR AT TENANT'S ELECTRICAL CONTRACTOR'S EXPENSE. 16. SALES AND NON -SALES CEILING SPACE IS USED AS A RETURN AIR PLENUM. ALL LOW VOLTAGE WIRES SHALL BE IN CONDUIT. 17. ELECTRICAL /MECHANICAL SHOP DRAWINGS AND CONTROL DIAGRAMS SHALL BE PLACED IN A NOTEBOOK AND MOUNTED AND CHAINED TO THE WALL BESIDE THE DRAWING TUBE. AS -BUILT DRAWINGS AND CONTROL DIAGRAMS SHALL BE PLACED IN THE DRAWING TUBE. DRAWING TUBE SHALL BE LOCATED BELOW THE UTILITY PANELS. VERIFY EXACT LOCATION WITH T.S.P.'S CONSTRUCTION MANAGER IN FIELD PRIOR TO MOUNTING. POWER CODED NOTES TELEPHONE OUTLET IN WALL TO INCLUDE BOX AND BLANK PLATE. ELECTRICAL CONTRACTOR TO RUN A 3/4" CONDUIT, WITH TWO TWISTED PAIR CABLE, BACK TO TELEPHONE BOARD. TELEPHONE WIRE AND #RJ14C JACK FOR TWO LINE TELEPHONE BY ELECTRICAL CONTRACTOR. REFER TO "TELEPHONE /COMPUTER SYSTEM SCHEMATIC" ON SHEET ED -1 FOR ADDITIONAL INFORMATION. MOUNT TELEPHONE OUTLET AT 36" A.F.F. UNLESS NOTED OTHERWISE. 2'W X 4'H X 3/4" TELEPHONE BOARD WITH DEDICATED QUADRAPLEX RECEPTACLE AND CIRCUIT WITH ISOLATED GROUND. VERIFY SYSTEM GROUNDING AND ALL OTHER REQUIREMENTS WITH LOCAL TELEPHONE COMPANY. EXTEND 1" TELEPHONE CONDUIT WITH PULLWIRE FROM SERVICE ENTRANCE AT DEMISING WALL TO TELEPHONE BOARD. VERIFY EXACT LOCATION IN FIELD. TENANT SHALL PROVIDE PLENUM RATED WIRE FROM THE LANDLORD'S TELEPHONE ROOM TO THE TENANT'S TELEPHONE EQUIPMENT WITHIN THE DEMISED PREMISIS UTILIZING THE LANDLORD SUPPLIED CABLE TRAY. 4" X 4" JUNCTION BOX IN WALL, WITH COVERPLATE, INSTALLED AT 66" A.F.F. AND 120 VOLT QUADRAPLEX RECEPTACLE INSTALLED AT 66" A.F.F. FOR SOUND SYSTEM. RUN ONE CONDUIT, SIZE AS SHOWN ON DETAIL, WITH PULLWIRE. UP IN WALL TO ABOVE CEILING. ELECTRICAL CONTRACTOR TO RUN A 1/2" CONDUIT TO EACH SPEAKER LOCATION WHERE/WHEN REQUIRED BY CODE. ELECTRICAL CONTRACTOR TO PULL SPEAKER WIRE AS INDICATED ON PLANS, LEAVING 36" SLACK WIRE AT EACH SPEAKER ENCLOSURE AND AT THE JUNCTION BOX. REFER TO "SOUND SYSTEM DETAIL" ON SHEET ED -1 FOR ADDITIONAL INFORMATION ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL "CALL FOR AID SYSTEM ". FIELD VERIFY EXACT LOCATION AND HEIGHT WITH LANDLORD IN FIELD PRIOR TO BID. INCLUDE ALL COSTS IN BID. 0 0 eO I� 15 3®GFI 0 44 "A.F.F. L B -12 HALLWAY VAVw1� . HV -1 /3/5 r �" 1 1 1 A -]7 L ���� B -15 �. . . T!JiI1iI � I II • IL I • • r • H.C. FTG. RM. • • • • • • r • • FTG. RM. Lr FTG. RM. 14. ENCLOSURE WITH SENSORMATIC POWER PACK AND DUPLEX RECEPTACLE WITH ISOLATED GROUND SHALL BE MOUNTED ON VERTICAL FACE OF SOFFIT ABOVE CEILING GRID. COORDINATE SENSORMATIC FREQUENCY WITH ADJACENT SENSORMATIC SYSTEMS. SEE SENSORMATIC DETAIL ON SHEET ED -1. PAINT ENCLOSURE TO MATCH CEILING. NON -SALES 0 14 0 20 AMP, 120 VOLT SINGLE PHASE DEDICATED CIRCUIT AND TWO (2) HUBBELL #IG -5362 RECEPTACLES WITH ISOLATED THIRD WIRE GROUND IN A SINGLE 3/4" CONDUIT BACK TO PANEL FOR COMPUTER TERMINAL. MOUNT RECEPTACLES AT 36" A.F.F. TO BOTTOM. FIELD VERIFY EXACT LOCATION WITH T.S.P.'S CONSTRUCTION MANAGER PRIOR TO ELECTRICAL ROUGH -IN. FURNISH AND INSTALL LOCK -OFF DEVICE ON BREAKER. INSTALL 8" X 8" X 4" PULLBOX, WITH COVERPLATE, ABOVE CEILING ON WALL ABOVE MANAGER'S DESK AREA. REFER TO "CASH WRAP /BACK WRAP PLAN" AND TELEPHONE /COMPUTER WIRING SCHEMATIC" ON SHEET ED-1 FOR ADDITIONAL INFORMATION. DATA CABLING BY OTHERS. 0 JUNCTION BOX AND DATA OUTLET AT 36" A.F.F. TO BOTTOM FOR COMPUTER TERMINAL. FIELD VERIFY EXACT LOCATION WITH T.S.P.'S CONSTRUCTION MANAGER PRIOR TO ROUGH -IN. REFER TO "TELEPHONE /COMPUTER SCHEMATIC" ON SHEET ED -1 FOR ADDITIONAL INFORMATION. DATA CABLE AND #RJ11C JACK BY OTHERS. 11 7-DAY, 24-HOUR DIGITAL TIME CLOCK IN A NEMA 1 ENCLOSURE FOR CONTROL OF ZONE "A" LIGHTS /RECEPTACLES. 1] PROVIDE TYPEWRITTEN PANELBOARD CIRCUIT BREAKER LEGENDS. SEE PANEL SCHEDULE FOR CIRCUIT BREAKERS TO RECEIVE LOCKING DEVICES. 13 FOUR REGISTER CASH WRAP /BACK WRAP COUNTER. ELECTRICAL CONTRACTOR TO PERFORM ALL WORK AS INDICATED IN THE "CASH WRAP /BACK WRAP DETAIL(S)" AS SHOWN ON SHEET ED -1. REFER TO ARCHITECTURAL FLOOR PLANS FOR EXACT ROUGH -IN INFORMATION. LIGHTING CONTACTORS IN NEMA 1 ENCLOSURE FURNISHED BY T.S.P. AND INSTALLED BY ELECTRICAL CONTRACTOR TO BE CONTROLLED BY T.S.P. 7-- DAY, 24-HOUR DIGITAL TIME CLOCK. 16 CEILING RECESSED SOUND SYSTEM SPEAKER. SEE SOUND SYSTEM INSTALLATION DETAIL ON SHEET ED -1 FOR ADDITIONAL INFORMATION. ]7 LANDLORD PROVIDED JUNCTION BOX FOR FIRE ALARM INTERFACE. CONNECT TO CIRCUIT INDICATED. ELECTRICAL CONTRACTOR SHALL CONTACT LANDLORD'S FIRE ALARM CONTRACTOR, FRANK CLOSE (FCLOSE@GUARDIANSECURITY.COM) OR BOB VEZZANI (BVEZZANIOGUARDIANSECURITY.COM) WITH GUARDIAN SECURITY AT ]- 800- 282 -6998 TO OBTAIN ENGINEERED FIRE ALARM DRAWINGS TO BE SUBMITTED FOR APPROVAL TO THE AUTHORITY HAVING JURISDICTION, FIRE ALARM DEVICE PRICING, AND FIRE ALARM INSTALLATION OPTIONS /PRICING. VERIFY EXACT REQUIREMENTS AND JUNCTION BOX LOCATION IN FIELD PRIOR TO BID AND INCLUDE ALL COST IN BID. 18 SENSORMATIC SYSTEM PROVIDED BY T.S.P.. REFER TO SENSORMATIC DETAIL ON SHEET ED-] FOR ELECTRICAL CONTRACTOR'S RESPONSIBILITIES. 19 ELECTRICAL CONTRACTOR TO PROVIDE A DUPLEX RECEPTACLE AT 18" A.F.F. FOR CONNECTION TO THE PHOTO BOOTH. VERIFY EXACT LOCATION AND REQUIREMENTS WITH T.S.P.'S CONSTRUCTION MANAGER. COORDINATE EXACT LOCATION OF PANELBOARDS WITH EXISTING CONDITIONS TO PROVIDE DEDICATED SPACE REQUIRED PER N.E.C. 384 -4. B -5 r!lo B -14 � B -6 ���� IU 8 -17 L_ _J <E) 4E) B -18 B 4- REGISTER CASHWRAP UNIT. USE CIRCUIT$ "B -1 & 3" SEE DETAIL w VAV— HV- 7/9/11 I 1 L. 1 1 I • DOOR CHIME FURNISHED BY T.S.P. AND INSTALLED ON DOOR BY ELECTRICAL CONTRACTOR. FTG. RM. SOUND SYSTEM VOLUME CONTROL IN WALL AT 48" A.F.F.. EXTEND EMPTY 3/4" CONDUIT UP IN WALL AND STUB OUT ABOVE CEILING OR STUBBED OUT AT 13' -0" A.F.F.. ELECTRICAL CONTRACTOR IS TO INSTALL T.S.P. PROVIDED PLENUM RATED 3- CONDUCTOR SHIELDED CABLE FROM VOLUME CONTROL TO 4" X 4" SOUND SYSTEM JUNCTION BOX ABOVE CEILING AT MANAGER'S DESK. VOLUME CONTROL AND FINAL CONNECTIONS BY DMX. ZONE DAMPER OR SMOKE /FIRE DAMPER TRANSFORMER FURNISHED BY T.S.P. AND INSTALLED BY MECHANICAL CONTRACTOR. 120 VOLT POWER WIRING BY ELECTRICAL CONTRACTOR ON NIGHT LIGHT CIRCUIT. ELECTRICAL CONTRACTOR IS TO INSTALL DUPLEX RECEPTACLE IN BASE AT SHOW WINDOW PLATFORM. COORDINATE EXACT LOCATION WITH T.S.P. CONSTRUCTION MANAGER IN FIELD. ELECTRICAL CONTRACTOR 15 TO INSTALL DUPLEX RECEPTACLE 18" ABOVE SALES FLOOR TO CENTER. 1 1 FTG. 1 RM. 1 11 m a► ile 0 FTG. RM. B -10 r TYP) SALES REVISIONS No changes shall be made to the l scope of work without prior app of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. n. i f r• i ST E r O Ti Ir r' A! APPROVED P!. .: ,� .� _, . -�,, a.,A ! �r � L I' ^T 77 C! !A MODIFIED OR ALIERED WITHOUT AUTHORIZATION FROM THE BUILDING • orrnAL, ALL WORK SHAM BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND IS TO FIELD INSPECTIONS , l B _.4 VERIFY: ALL CONDITIONS D.1 0 1 1 A -5 (TYP) COVERPLATE IN BASE. FILE COPY 000 P�nitl�b. �i�� - Plan goyim is ettieotto ems and missions. Approval of co11lNIICu0f1 dDE1C11m11{8 does not authorize the violation 0f any8d0pt8Q170dB0 [ordnance. Receipt of approved Copyand acknowledged: D a t e: . City of Tukwila BUILDING DIVISION Y REVISION NO.2_ : ELo7 Boo 07 (2 ) REVIEWED O PUAANCE CODE N M 70 -NEC APR - 2 2008 Of Tukwila EUIL®N DINT ION Works, Building DivlsTon PERMIT NUMBER 81 RECEIVED MAR 0 7 2008 PERMIT CENTER N:.FIELD....PRIOR , TO BIDS. PROVIDE TWO DEDICATEI WITH ISOLATED• GROUND 120 VAC ©183mA GND ,+24VDC CTRL NORM SET LEVEL F-- LOW MIN --3 PLAN SECTION A ELEVATION MOUNT ON SHELF ABOVE MANAGER'S DESK. $- CASHWRAP & BACKWRAP 2 COND. 20 AWG W /SHIED RDL PS -24A 24 Vdc 400 mA POWER SUPPLY TRANSFORMER (MD. REF.) LOCATE REMOTE LEVEL CONTROL SWITCH ON NON —SALES SIDE OF SALES /NON —SALES DOOR. VERIFY EXACT LOCATION IN FIELD WITH T.S.P. CONSTRUCTION MANAGER. 2 COND. 20 AWG W /SHIELD C100 A 1 CASHWRAP /BACKWRAP DETAIL ED-1/ N.T.S. PROVIDE TWO D CIRCUITS WITH ISOLATED• 5 FOR CASH REGISTERS. IDENTIFY SUCH CIRCUITS ON COVERPLATES. SEE PLAN AND SCHEDULES FOR ADDITIONAL INFORMATION. CIRC. #2) RDL ST- VCA2 VOLTAGE CONTROLLED AMP RF_D I= 1 fBLK 1•-- -I LINE 10V OUT LINE OUT MOUNT ON PROFUSION '. USING SUPPLIED "DUAL —LOCK" VELCRO.. CONE, h P dILLD AMPLIFIER SOUND SYSTEM INSTALLATION DETAIL SECTION B 120 VAC D 834mA LIMITED TOO CASH /WRAP CODED NOTES TWO 20 AMP, 120 VOLT DEDICATED CIRCUITS EACH WITH ISOLATED GROUND IN A 1" CONDUIT. EXTEND CONDUIT BACK TO PANEL FOR CASH REGISTERS. DO NOT INSTALL WITH ANY OTHER CIRCUITS. STUB CONDUIT UP 6" A.F.F. INTO CASHWRAP UNIT. CONNECT 1" FLEXIBLE METALLIC CONDUIT TO STUB —UP AND EXTEND UP TO CONTRACTOR FURNISHED JUNCTION BOX IN CASHWRAP. RUN A 3/4" FLEXIBLE METALLIC CONDUIT FROM JUNCTION BOX TO CASH REGISTER ISOLATED GROUND RECEPTACLES (WIRE TWO "QUADS" PER CIRCUIT AS SHOWN). RECEPTACLES SHALL BE HUBBELL IG -5362, 20 AMP ISOLATED GROUND TYPE FURNISHED BY "TWEEN BRANDS STORE PLANNING" AND INSTALLED AND WIRED IN CASHWRAP BY ELECTRICAL CONTRACTOR. CUT AND PATCH FLOOR AS REQUIRED TO ROUTE CONDUIT CONCEALED IN WALL UP TO CEILING SPACE AND EXTEND TO PANEL. TWO 1" CONDUITS WITH PULLWIRE FOR DATA CABLING TO CASH REGISTERS. CUT AND PATCH FLOOR AS REQUIRED TO ROUTE CONDUITS BELOW FLOOR SLAB TO WALL AS SHOWN. ROUTE CONDUITS CONCEALED IN WALL UP TO CEILING SPACE AND EXTEND TO AN 8" X 8" X 4" PULLBOX ON WALL ABOVE MANAGER'S DESK AREA IN STOCKROOM FOR DATA CABLING FISHED AND INSTALLED BY "TWEEN BRANDS STORE PLANNING ". SEE NOTE 9 ON SHEET E -1 POWER PLAN FOR ADDITIONAL INFORMATION. 20 AMP, 120 VOLT RECEPTACLE AT BACKWRAP. CONNECT TO LOCAL CIRCUITRY AS NOTED ON SHEET E -1. DATA TERMINAL(S) AND CONNECTIONS BY "TWEEN BRANDS STORE PLANNING" P.O.S. CONTRACTOR. PROVIDE 3/4" CONDUIT WITH PULLWIRE FROM STUB UP IN BOTTOM OF CASHWRAP CABINET BACK TO TELEPHONE BOARD. TELEPHONE CABLE AND DUPLEX #RJ14C JACK F 2 —LINE TELEPHONES BY "TWEEN BRANDS STORE PLANNING" SEE NOTE 5 ON SHEET E -1 POWER PLAN FOR ADDITIONAL INFORMATION. PROVIDE JUNCTION BOX FOR DUPLEX TELEPHONE OUTLET IN BACKWRAP CUTOUT. PROVIDE 3/4" CONDUIT WITH PULLWIRE BACK TO TELEPHONE BOARD. TELEPHONE CABLE AND DUPLEX #RJ14C JACK FOR 2 —LI TELEPHONES BY "TWEEN BRANDS STORE PLANNING ". SEE NOTE 5 ON SHEET E -1 POWER PLAN FOR ADDITIONAL INFORMATION. BUZZER IN OUTLET BOX WITH LOUVERED COVER PLATE MOUNTED IN BACKWRAP AND EXTEND TO PUSHBUTTON. BUZZER SYSTEM SHALL BE FURNISHED BY "TWEEN BRANDS STORE PLANNING" 1 BY LIMITED TOO ELECTRICAL CONTRACTOR. SEE NOTE ON SHEET E -1 POWER PLAN FOR ADDITIONAL INFORMATION. 4" x 4" EMPTY JUNCTION BOX FURNISHED AND INSTALLED WITH CASHWRAP COUNTER. ELECTRICAL OUTLETS FURNISHED BY "TWEEN BRANDS STORE PLANNING" AND INSTALLED BY ELECTRICAL CONTRACTOR (TYP. OF 4 LOCATIONS). NOTE: ELECTRICAL CONTRACTOR MUST INSTALL CONDUITS AS SHOWN. ELIMINATE INTERIM JUNCTION BOXES WHEREVER POSSIBLE. SUPPLY PULLWIRE IN EACH CONDUIT. MAKE ALL FINAL ELECTRICAL CONNECTIONS TO RECEPTACLES, TELEPHONE OUTLETS. ETC. AS REQUIRED FOR A COMPLETE WORKING SYSTEM. NO CHASING OR CUTTING OF THE FLOOR SLAB, EXCEPT FOR SLABS ON— GRADE, WILL BE ALLOWED. ALL CONDUITS AND /OR PIPING MUST BE RUN BENEATH THE SLAB AND ALL SLAB PENETRATIONS SHALL BE FULLY SLEEVED AND FLASHED. COORDINATE ALL FLOOR SLAB CUTTING WITH MALL OPERATIONS MANAGER. NOTE 2 -TO -1 TELEPHONE SPLITTER TO BE PROVIDED BY DMX TECH. 2 COND. 18 AWG APHEX 520D TOA P-906 AMPLIFIER INPUT RED BLK MANAGER'S DESK SHELF ® DIGITAL CONTROLLER PACK O2 DEDICATED 120 VOLT CIRCUIT WITH ISOLATED GROUND AS SHOWN IN PANEL SCHEDULE CEILING 2 SENSORMATIC EQUIPMENT PROVIDED BY T.S.P. INSTALLED BY G.C. LEASE LINE ROUTE CONDUIT UP WALL OR COLUMN TO CEILING SPACE — 8" MIN. 27 3/4*- SOUND SYSTEM GENERAL NOTES SOUND SYSTEM CODED NOTES STORE ENTRANCE ELEVATION 1. ELECTRICAL CONTRACTOR MALL INSTALL SPEAKER ENCLOSURES AND SUPPORTS AS FURNISHED BY "T.S.P.". ELECTRICAL CONTRACTOR IS TO FURNISH ADDITIONAL HARDWARE (I.E.- MOUNTING BRACKETS, SCREWS, CLIPS, ETC.) AS REQUIRED FOR SOUND SYSTEM INSTALLATION. FOR CUSTOM PAINTED CEILING, THE SPEAKER GRILLES WILL BE SHIPPED EARLY TO BE PAINTED BY THE GENERAL CONTRACTOR. 2. PROFUSION "X" DIGITAL MEDIA MANAGER, VOLTAGE AMPLIFIER, TOA AMPLIFIER, SPEAKERS. SPEAKER GRILLES FURNISHED BY T.S.P. AND INSTALLED BY ELECTRICAL CONTRACTOR. ALL FINAL CONNECTIONS TO BE MADE BY DMX. 3- SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT QUANTITY AND LOCATION OF SPEAKERS. ELECTRICAL CONTRACTOR SHALL NOTE ANY CONFLICTS IN FIELD AND NOTIFY T.S.P. CONSTRUCTION MANAGER OF SAME. CIRCUIT CHANGE MUST BE APPROVED BY T.S.P. CONSTRUCTION MANAGER. NOTE: SPEAKERS THAT MUST BE MOVED, DUE TO FIELD CONDITIONS, MUST MAINTAIN A SYMMETRICAL PATTERN. 4. ANY QUESTIONS REGARDING MUSIC SYSTEM SHALL BE DIRECTED TO T.S.P. CONSTRUCTION MANAGER. RECESSED CEILING SPEAKER FURNISHED BY T.S.P. AND INSTALLED BY ELECTRICAL CONTRACTOR. 2® SPEAKER WIRE FURNISHED BY "T.S.P." AND INSTALLED BY ELECTRICAL CONTRACTOR, (18 GAUGE, 2 CONDUCTOR TWISTED CL2P PLENUM RATED CABLE). NO SUBSTITUTIONS ALLOWED. INSTALL WIRE IN CONDUIT, BETWEEN SPEAKER ENCLOSURES AND TO SOUND SYSTEM LOCATED IN NON —SALES AREA. INSTALL WIRE IN 1" CONDUIT DROP IN WALL TO JUNCTION BOX. PROFUSION "X" DIGITAL MEDIA MANAGER, VOLTAGE AMPLIFIER AND TOA AMPLIFIER FURNISHED BY "T.S.P." AND INSTALLED BY ELECTRICAL CONTRACTOR ON SHELF IN MANAGER'S OFFICE. SHELF FURNISHED AND INSTALLED BY GENERAL CONTRACTOR. JUNCTION BOX FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR AT 66" A.F.F. TO CENTER WITH 1" CONDUIT UP IN WALL AND STUBBED OUT 6" ABOVE FINISHED CEILING OR 13'-0" A.F.F. IF NO CEILING. BUSH BOTH CONDUIT ENDS. INSTALL SPEAKER WIRING TO ALL SALES AREA SPEAKERS IN A SEQUENTIAL CIRCUIT LEAVING 36" OF SLACK WIRE, BELOW CEILING LINE. AT EACH SPEAKER LOCATION. MAXIMUM OF 25 SPEAKERS PER CIRCUIT. ®6 INSTALL 3' -0" OF COILED SPEAKER WIRING FOR EACH CIRCUIT. LABEL AND TAG EACH CIRCUIT AT SOUND SYSTEM AS TO AREA SERVED. VOLUME CONTROL WITH EMPTY 3/4" CONDUIT STUBBED ABOVE CEILING OR STUBBED OUT AT 13'-0" A.F.F. AT SALES /NON —SALES DOOR. PLENUM RATED 3— CONDUCTOR SHIELDED CABLE FURNISHED BY T.S.P. AND INSTALLED BY ELECTRICAL CONTRACTOR. ALL FINAL CONNECTIONS BY DMX. ROLLING GRILLE ANTENNA 10 RS232 PLATE REMOTE CEILING MOUNTED ALARM THIN DIGITAL FLOOR MAX DETAILS INI i— TOP OF FSHED FLOOR TELPHONE & DATA WIRING DIAGRAM THIN DIGITAL FLOOR MAX CODED NOTES �1 3/4" CONDUITS INTERCONNECT BETWEEN CAPACITOR BOARD AND POWER PACK LOCATED ABOVE CEILING AND IN —FLOOR ANTENNA. CONDUIT SHALL BE CONCEALED IN FALSE COLUMNS AND SHALL NOT EXCEED 35 FEET IN LENGTH. 2® DUPLEX RECEPTACLE BOX LOCATED IN AREA ABOVE CEILING. ELECTRICAL REQUIREMENTS ARE 120 VAC , THREE WIRE, ISOLATED GROUND, 24 HOUR CIRCUIT WITH LESS THAN 0.5 VAC BETWEEN NEUTRAL AND GROUND. INSTALLATION AND TRANSFORMER AND INTERCONNECT CABLE BY OTHERS. ® RETURN AIR GRILLE OR ACCESS PANEL TO BE USED FOR SERVICING OF EQUIPMENT LOCATED ABOVE THE CEILING. COORDINATE ROUGH—IN OF JUNCTION BOX AND RECEPTACLE WITH THE GENERAL CONTRACTOR. 4 AUDIBLE ALARM SPEAKER IN CEILING. ALARM FURNISHED AND INSTALLED BY OTHERS. ® 3 1/2" DEEP FLOOR CAVITY, LOCATED BETWEEN STORE OPENING AS SHOWN ON PLAN VIEW DETAIL. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT OPENING LENGTH AND NUMBER OF PANELS. ® DIGITAL CONTROLLER PACK UNIT LOCATED INSIDE ENCLOSURE. DIGITAL CONTROLLER PACK FURNISHED AND INSTALLED BY SENSORMATIC. 7 APPROVED HOFFMAN ENCLOSURE ZP700, PART #0351 - 1150 -01, PROVIDED BY T.S.P. AND INSTALLED BY ELECTRICAL CONTRACTOR. ® USE SEPARATE CONDUIT RUN FOR EACH ANTENNA. • CAPACITOR BOARD /DIFFERENTIAL AMPLIFIER AND ENCLOSURE. MAXIMUM DISTANCE FROM POWER PACK TO CAPACITOR BOARD /DIFFERENTIAL AMP ENCLOSURE IS 7' -0 ". CS 2" X 4" JUNCTION BOX AND 1/2" CONDUIT WITH PULLWIRE TO CAPACITOR BOARD FOR REMOTE TEST SWITCH AND PROGRAMMING JACK. COORDINATE EXACT LOCATION WITH T.S.P. CONSTRUCTION MANAGER IN FIELD. MAXIMUM DISTANCE FROM CAPACITOR BOARD TO JUNCTION BOX IS 25' -0 ". FOR TECHNICAL QUESTIONS REGARDING INSTALLATION CAW 1 -800- 327 -1765 1 -800- 241 -6678 NOTE ALL CONDUITS WITHIN THE SENSORMATIC TRENCH SHALL BE SCHEDULE 40 PVC. TRANSITION FROM PVC TO RIGID GALVANIZED STEEL CONDUIT BELOW FLOOR AND EXTEND RIGID GALVANIZED STEEL CONDUITS UP TO SENSORMATIC 1 EQUIPMENT. CONDUIT W/ PULL WIRE MANAGER'S DESK 2 — 1" CONDUITS W/ PULL WIRE 36" A.F.F. 1. FIXTURES MARKED WITH "1" ARE PROVIDED WITH A MASTER MULTI —LAMP BALLAST. 2. FIXTURES MARKED WITH "2 ", "3 ", AND "4" ARE PRE —WIRED TO THE MASTER MULTI —LAMP BALLAST. 3. FOR CLARITY, FACTORY PRE — WIRING 1S NOT INDICATED ON LIGHTING PLAN. 4. FOR MORE INFORMATION, CONTACT DOUG HAMRICK OF LOEB ELECTRIC AT (614) 294 -6351. FLUORESCENT FIXTURE WIRING NOTE: �_/ 1. ADDITIONAL PHONE OUTLETS MAY BE REQUIRED. SEE FLOOR PLAN FOR LOCATION. QTY TYPE AREA TAP X JBL C26CT MAIN SALES 7.5W EXPIRES 6/10/ 0 THE ENGINEER ASSUMES NO RESPONSIBILRY OR UABIUTY FOR THE USE OF THESE PLANS FOR ANY PROJECT OTHER THAN SPECIFICALLY AUTHORIZED BY THEM AND SIGNED AND SEALED FOR SUCH SPECIFIC LOCATION IN THE STATE SHOWN ON THE SEAL THIS BUILDING USE IS ONLY APPLICABLE IN AREAS MEETING THE STATED DESIGN CRITERIA. LIMITED TOO ELECTRICAL EQUIPMENT SCHEDULE DE IS USED SYMBOL DESCRIPTION MANUFACTURER & MODEL NUMBER FURN.BY MAX WATTS INPUT WATTS 'O NI 1 ' d'S'l c TRACK LIGHT LIGHTOLIER 8239WH/8202V1H & 50PAR30 /HIR /SP9* LAMP. T.S.P., INC. 75W /FT 50 O 0 TRACK UGHT LIGHTOLIER 9022WH w/ 100PAR /HIR /FL25' LAMP T.S.P., INC. 75W /FT 100 • ® O RECESSED DOWNLIGHT HANGER & (2)F26DBXT4 /SPx30 /4P LAAMP. BAFFLE T.S.P., INC. 52 52 • © TRACK UGHT LIGHTOLIER 9023WH & SOPAR30/HIR /SP9' AMP T.S.P., INC. 75W /FT 50 SERVICE ENTRANCE CONDUIT(S) TO LEASE SPACE 0 PENDANT DOWNLIGHT ALTMAN PAR38CDMCUS W/72" PAINTED STEM, CANOPY, 712X712 LENSE & CMH7O/PAR38 /830WF LAMP T.S.P., INC. 70 81 ---' 0 0 PENDANT DOWNLIGHT SONOMA CVWL & 100A/90WM LAMP T.S.P., INC. 100 90 AIR CONDITIONING SYSTEM FQ TRACK UGHT TRANSUTE- SONOMA FLEXIBLE TRACK 1BT4- 505 -B -AL WITH BT- 526 -AL XFMR, FLX- BTC -NG HEAD & 050MR16 /C/NFL25' LAMP T.S.P., INC. 300 300 O VERIFY IN FIELD SERVICE ENTRANCE FEEDER(S) TO LEASE SPACE PENDAN WN DO LIGHT T RAIL T.B.D. T.S.P.. INC. 300 300 IQI ®I®1 0.104 1MISCELLANEOUS 0 COLOR PROJECTOR COLOR KINETICS #C -200. LE.D. LAMPS INCLUDED. 24 V.D.C. POWER PROVIDED BY LIGHTING CONTROLLER. T.S. P" N/A N/A . 0 MONOPOINT HALO MSP4338 W /LUMIERE PHVS50 WHITE TRIM, AND 050MR16NSP15 -EXT. LAMP T,S,P., INC. 55 55 STEP -DOWN TRANSFORMERS AND MOUNTING ACCESSORIES (AS REQUIRED) QD RECESSED ADJ. DOWNLIGHT CON -TECH UGHTING 4 LAMP #RAN5016X4 & Q50MR16 /C/NFL25' GE LAMP T.S.P. INC. 220 220 O © e l RECESSED ADJ. DOWNLIGHT JUNO 3 -LAMP #MS303 -WH W/ (3) 75PAR30 /H /FL25' LAMP T.S.P., INC. 225 225 0 0 Qz PENDANT DOWNLIGHT SONOMA WG12 W/ FLE28QBX/SPX27 (28 WATT COMPACT FLUORESCENT) LAMP T.S.P., INC. 28 28 0 Q PENDANT DOWNLIGHT SONOMA WHGL16 w/ FLE28QBX /SPX27 (28 WATT COMPACT FLUORESCENT) LAMPCOMPACT FLUORESCENT) LAMP T.S.P., INC. 28 28 Q PENDANT DOWNUGHT SONOMA WG20 W/ FLE280BX /SPX27 (28 WATT COMPACT FLUORESCENT) LAMP T.S.P„ INC, 28 28 LO M I 1 SINGLE TUBE FLUORESCENT 4 FT FLUORESCENT STRIP WITH LAMP GUARD - " DURAY" #DUFEQH- 1132 -120 WITH (1) F32T8XL /SP3O /IS /WM /ECG T.S.P., INC. 38 38 z O RECEPTACLES: NON -SALES AREA 0.532 0 FL ORESCENT WITH F32T8 /s 30% /6 I X 2U6T8S331 T.S.P., INC, 71 71 r4 C 16 POWER WIRING TO HVAC EQUIPMENT FLUO WITH F32T8XL /SP30/IS AMP T.S.P., INC, 90 90 c5l0 C • 1.500 LO C EXIT LIGHT HIGH -LITE #BPSLED5RBK W/ BATTERY PACK SALES AREA ONLY (LE.D., SURFACE MTD). T.S.P., INC. 5 5 0 NL /EM SALES ® ® EXIT UGHT HIGH -LITE ; : PSLED5R W/ BATTERY PACK NON -SALES AREA ONLY (L.E,D., SURFACE MTD). T.S.P., INC. 5 5 0 EXIT MERG. LIGHT H ACK -LITE . "NON #BPSLED SALES" 5RDEH36 ONL (L WITH BATTERY E D., SURFACE MTD.) PA T.S.P., INC. 5 5 O 0.300 AimmiN EMERGENCY LIGHT HIGH-UTE #XC -1 -W W/BATTERY PACK WALL MTD. 2 BELOW CEILING (IF PRESENT) OR 11 -0 A.F.F. T.S.P., INC. 10 10 SPARE 0 23 CEILING EXHAUST FAN GREENHECK #SPB150 W/ OPTIONAL STEEL GRILLE, 120 V, 1 PHASE, 113 WATTS, T.S.P., INC. 113 113 0.416 C x I SINGLE TUBE FLUORESCENT DURAY EQH -1125 -120 W/ F25T8 /SP30 LAMP, 120V. T.S.P., INC. 30 30 • 4 SINGLE TUBE FLUORESCENT DURAY EOH-1132-120 W/ F32T8XL /SP30/IS/WM/ECO LAMP T.S.P., INC. 38 38 I x r' 0 I' 4�T SINGLE TUBE FLUORESCENT DURAY Q13132 -120 CHAIN HUNG W/ F32T8XL /SP30/IS/WM/ECO LAMP, 120V. MOUNT AT 12' -6' AF.F. TO BOTTOM OF REFLECTOR T.S.P . INC, ' 38 38 I O $ TS TOGGLE SWITCH HUBBELL TOGGLE TYPE SWITCH CONTR. - - O T y TELEPHONE OUTLET LOCATED IN BASE UNLESS OTHERWISE NOTED CONTR. - - • V C DATA OUTLET LOCATED IN � BASE UNLESS OTHERWISE NOTED CONTR. - - ® a BUZZER SEE CODED NOTE 4 SHEET E -1 T,S.P., INC. - - ® 30 31 0 BUZZER BUTTON SEE CODED NOTE 4 SHEET E -1 T.S.P., INC. _ _ A - -- • di DUPLEX RECEPT. LEVITON #5352W OR #5352L (WALL MOUNTED) CONTR. 180VA 180VA • oGF DUPLEX UL C REPT. KT, LEVITON #6899. (GROUND FAULT WALL MOUNTED) CONTR. 180VA 180VA • - -- DOUBLE RECEPT. D LEVITON #5352W OR #53521. (WALL MOUNTED) CONTR. 36OVA 360VA 35 S3 3 3- HUBBELL #1223-COLOR SHALL BE IVORY CONTR. -- - • MUSIC SYSTEM /SPEAKERS /CABINET - -- TRANSFORMER SEE SPECIFICATIONS T.S.P., INC. - -- U. • - -- MUSIC SYSTEM WIRING IN CONDUIT - -- MOTION SWITCH LEVITON 16775W T.S.P., INC. - .- NS • ® MUSIC SPEAKER FURNISHED BY OWNER - 1/2' CONDUIT (IF REQ'D BY CODE) BY E.C. T,S,P., INC. - - - -- WP ABBREVIATION WEATHERPROOF DEVICE - - - 40 SQ AIR TEMP. SENSOR FURNISHED BY T.S.P. T.S.P., INC. - - - -- 3'.5'00' MULTI- OUTLET RACEWAY WIREMOLD SPLW2OGB306 (3' -0" LENGTH), SPLW2OGB506 (5' -0" LENGTH), SPLW20GB12006 (10' -0" LENGTH) COLOR SHALL BE WHITE (WITH GIRL CARE WALL PACKAGE) T.S.P.. INC. - - • 1 '• 0 EXT LIGHT SURE UGHT #LPXH7QRWH W /BATTERY PACK AND REMOTE HEAD CAPACITY T.S.P., INC. 5 5 w ei REMOTE EMER. HEAD BEST #RH1WP REMOTE EMERGENCY LIGHT WIRED OFF EXIT SIGN T.S.P. INC. - THIS SCHEDULE IS INTENDED AS A "QUICK" REFERENCE. ON THESE DRAWINGS. IF THE CONTRACTOR ENCOUNTERS RESPONSIBILITY TO INFORM T.S.P.'S CONSTRUCTION FOR THE CONTRACTOR. ELECTRICAL RESPONSIBILITY SCHEDULE ITEM FURNISHED BY INSTALLED BY ONI LSIX3 REMARKS ELEC. CONTR. LANDLORD 'O NI 1 ' d'S'l OTHERS ELEC. CONTR. LANDLORD OTHERS V/N MAIN OVERCURRENT DEVICE IN LANDLORDS ELECTRIC ROOM O O 120V, 10 SHOW WINDOW LIGHTING ALLOWANCE O O 2.100 7,400"* ® ()VERIFY IN FIELD ELECTRICAL METER IN LANDLORDS ELECTRIC ROOM 0 0 1.0 7.200 0 0 7.200 --- 0 O VERIFY IN FIELD SERVICE ENTRANCE CONDUIT(S) TO LEASE SPACE 0 0 1.0 +25% LARGEST - -` 0 0 ---' 1.0 0 O VERIFY IN FIELD SERVICE ENTRANCE CONDUIT(S) FROM STUB IN LEASE SPACE TO UTILIZATION EQUIPMENT O O AIR CONDITIONING SYSTEM '" -- * O O --- * 1.0 ss* +25% LARGEST o O VERIFY IN FIELD SERVICE ENTRANCE FEEDER(S) TO LEASE SPACE 0 0 1.500 1.500 0 0 0.104 1MISCELLANEOUS 0 O VERIFY IN FIELD DISTRIBUTION PANELBOARDS 13.826 1.0 0 . 0 34.107 TWO CATEGORIES INSTALLED OF COMPRESSOR INCLUDED = MINIMUM 37.002 45,427 O STEP -DOWN TRANSFORMERS AND MOUNTING ACCESSORIES (AS REQUIRED) 0.250 VALUE OF THE 220-12 REQUIREMENT MINUS ACTUAL MOTOR IS ALREADY KVA x 1000 O UNIT. SERVICE O * USE GREATER ** N.E.C. ARTICLE SHOW WINDOW) * ** 125% OF THE LARGEST ♦ POWER FACTOR N.E.C. DEMAND SYSTEM VOLTAGE 51.152 x 1000 x 61.53 AMPS = 480 x 1.73 0 LIGHTING FIXTURES AND LAMPS SHOW WIN LTS 0 1.050 0 C 0.550 1.500 LO F TOILET EXHAUST FAN(S) C 12 13 SPARE 0 - -- A RECEPTACLES: SALES AREA 1.500 LO M 0 TRACK LTS. 0 14 15 NON -SALES LTS RECEPTACLES: NON -SALES AREA 0.532 0.532 0 0.550 0 LO L TRACK LTS. C 16 POWER WIRING TO HVAC EQUIPMENT 0 NL /EM NS LO 0 0.519 C 0.600 1.500 LO C LIGHTING CONTROL SYSTEM TRACK LTS. C 0 19 0 NL /EM SALES LO 0.951 0.951 POWER WIRING TO " CASHWRAP" 0 - -- 0 20 21 B FUTURE POWER WIRING AND CONDUIT FOR SENSORMATIC EQUIPMENT O 0.300 0.300 B O - -- SPARE POWER WIRING FOR ROLLING GRILLE 23 B DOWNLIGHTS 0.416 0.416 C - -- - -- DELIVERY BUZZER SYSTEM SPARE 0 24 0 SPARE - -- - - -- TELEPHONE OUTLETS AND CONDUITS 0 - -- - -- 0 SPARE 26 26 27 B DATA OUTLETS AND CONDUITS WITH PULLWIRE O - -_ - 0.468 0.468 O - -- - -- -- -SPACE 2 SPARE TELEPHONE CABLING AND CONDUIT • 29 B ADJ. DOWNLIGHT 0 - -- C 0.225 0.225 C --- DATA CABLING AND CONDUIT 30 SPARE 0 30 31 0 SPARE CEILING MID. SMOKE DETECTORS - -- A - -- - -- SPARE O 32 33 DUCT MTD. SMOKE DETECTOR FLUORESCENTS 1.136 1.136 B - -- - -- TENANTS FIRE ALARM SYSTEM (SEE DETAILS) 0 35 SPARE 0 - -- - -- AT EC'S EXPENSE MUSIC SYSTEM /SPEAKERS /CABINET - -- 0 SPARE 0 36 37 SPACE - -- MUSIC SYSTEM WIRING IN CONDUIT - -- - -- 0 ---- 0 -- -SPACE 38 0 MUSIC SYSTEM VOLUME CONTROL SPACE - 0 - -- B 0 - -- 0 TEMPERATURE CONTROL SYSTEM IN CONDUIT 40 41 SPACE _ -- - -- - -- C -- -- PLUGMOLD -- -SPACE 42 0 VAV- 1 &2 SERVICE LITE, SWITCH AND RECEPTACLE 0 GENERAL NOTE ALL ITEMS LISTED HERE ARE SPECIFIED AND DETAILED ITEMS THAT ARE CONTRADICTORY THEN IT IS HIS MANAGER SO THAT THESE ITEMS CAN BE CLARIFIED THIS SCHEDULE IS INTENDED AS A "QUICK" REFERENCE. ON THESE DRAWINGS. IF THE CONTRACTOR ENCOUNTERS RESPONSIBILITY TO INFORM T.S.P.'S CONSTRUCTION FOR THE CONTRACTOR. RESPONSIBILITY SCHEDULE CODED NOTES T.S.P.. 0 ALL FINAL CONNECTIONS TO EQUIPMENT BY 0 SEE POWER RISER FOR ADDITIONAL INFORMATION. ELECTRIC LOAD SUMMARY 277/480V DESCRIPTION - ACTUAL CONNECTED KW /KVA POWER FACTOR ACTUAL DEMAND - KVA N.E.C. CONNECTED KW/KVA N.E.C. DEMAND FACTOR N.E.C. DEMAND KVA BRANCH BREAKER LIGHTING 9.901 A 12.376 15.501 1.25 19.376 120V, 10 SHOW WINDOW LIGHTING ALLOWANCE 1.680 A 2.100 7,400"* 1.25 9.250 - -- RECEPTACLES 7.200 1.0 7.200 7.200 1.0 ING Q.5 REMAINING KW 7.200 --- MOTORS - -- 0.9 - -- * --- 1.0 +25% LARGEST - -` 1 FIXED ELECTRIC SPACE HEATING ---' 1.0 - -- * - -- * 1.0 - -- s AIR CONDITIONING SYSTEM '" -- * 1 . 0 ___ * --- * 1.0 ss* +25% LARGEST - -- * ELECTRIC WATER HEATER 1.500 1.0 1.500 1.500 1.0 1.500 0.104 1MISCELLANEOUS 13.826 1.0 13.826 13.826 1.0 13.82E . TOTAL NOTES 34.107 TWO CATEGORIES INSTALLED OF COMPRESSOR INCLUDED = MINIMUM 37.002 45,427 VA. ONLY ON ONE EXISTING 200 AMP 51.152 0.250 VALUE OF THE 220-12 REQUIREMENT MINUS ACTUAL MOTOR IS ALREADY KVA x 1000 (200VA PER FOOT OF SHOW WINDOW LIGHTING IN SYSTEM. APPLIED IN LIGHTING LOAD. FEEDER AMPERAGE REUSE UNIT. SERVICE * USE GREATER ** N.E.C. ARTICLE SHOW WINDOW) * ** 125% OF THE LARGEST ♦ POWER FACTOR N.E.C. DEMAND SYSTEM VOLTAGE 51.152 x 1000 x 61.53 AMPS = 480 x 1.73 TRANSFORMER LOAD SUMMARY 120/208V DESCRIPTION ACTUAL CONNECTED KW /KVA POWER FACTOR ACTUAL DEMAND KVA N.E.C. CONNECTED KW /KVA N.E.C. DEMAND FACTOR N.E.C. DEMAND KVA BRANCH BREAKER LIGHTING 11.581 1.0 14.476 18.381 1.25 22.976 120V, 10 RECEPTACLES 7.200 1.0 7.200 7.200 1 . 0 < 10Kw 0.5 REMAINING KW 7.200 - -- MOTORS - -- 0.9 - -- - -- 1.0 +25% LARGEST - -- --- FIXED ELECTRIC SPACE HEATING --- * 1.0 - -- * - -- • 1.0 - -- 1 AIR CONDITIONING SYSTEM - -- * 1 . 0 - -- * - -- * 1.0 ** +25% LARGEST - -- s ELECTRIC WATER HEATER 1.500 1.0 1.500 1.500 1.0 1.500 TRACK LTS. MISCELLANEOUS 1.000 1.0 1.000 1.000 1.0 1.000 0.104 TOTAL NOTES 21.281 TWO CATEGORIES OF COMPRESSOR 24.176 28.081 1 ONLY ON ONE - 32.676 C VALUE OF THE MOTOR IN SYSTEM. APPLIED UNIT. SHOW WIN LTS * USE GREATER ** 125% OF THE LARGEST USE 45 KVA TRANSFORMER EQUIPMENT WIRING SCHEDULE SW. ITEM VOLTAGE HP, KW, F.L.A. FEEDERS TYPE OF CONN. BRANCH BREAKER DISC. SW, BUSS FUSES REMARKS WIRE COND. 0 W HEATEATER R 120V, 10 -- 1.5 -- 2#12 THHN 1 #12 GRD 3/4" 'AC' TOGGLE SWITCH 20A -1P - -- ___ SEE NOTE NO, 1 BELOW ZO . VAV -1 & 2 277/480V 30, 4W 1 5.0 --- 4112 THHN 1 #12 GRD 3/4" DIRECT 20A -3P - -- - -- DISC. MEANS INTEGRAL TO UNIT . NOTES: . TO BE FURNISHED BY T.S.P. AND INSTALLED BY ELECTRICAL CONTRACTOR. 1. 'AC' TOGGLE SWITCH Ckt. No. Zone Load Description Brkr Size Size Brkr Opts N.E.C. Actual Phase Actual N.E.C. Brkr Opts Brkr Size Load Description Zone Ckt. No 1 A SIGN LO 1.200 1.200 A 0.350 0.350 FITTING RM. LTS. C 2 3 A SHOW WIN. REC. LO 0.540 0.540 B - -- -- -- LO S SPARE 4 5 A SHOW WIN. REC. LO 0.540 0.540 C 0.600 1.500 LO S TRACK LTS. C 6 7 A ENTRY LIGHTS J 0.104 0.104 A 0.600 1.650 LO W TRACK LTS. C 8 9 A SHOW WIN LTS LO 0.750 0.250 B 0.150 0.450 TRACK LTS. C 10 11 A SHOW WIN LTS LO 1.050 0.350 C 0.550 1.500 LO F TRACK LTS. C 12 13 SPARE - -- - -- A 0.650 1.500 LO M TRACK LTS. C 14 15 NON -SALES LTS LO 0.532 0.532 B 0.550 1.200 LO L TRACK LTS. C 16 17 NL /EM NS LO 0.519 0.519 C 0.600 1.500 LO C TRACK LTS. C 18 19 NL /EM SALES LO 0.951 0.951 A - -- - -- SPARE 20 21 B FUTURE 0.300 0.300 B - -- - -- SPARE 22 23 B DOWNLIGHTS 0.416 0.416 C - -- - -- SPARE 24 25 SPARE - -- - - -- - -- A - -- - -- -- -SPACE 2 SPARE 26 26 27 B FITTING RM LTS. . - -_ - 0.468 0.468 B - -- - -- -- -SPACE 2 SPARE 29 S 28 29 B ADJ. DOWNLIGHT - -- - - -- C 0.225 0.225 C --- - -- 30 SPARE 30 31 SPARE - -- - -- A - -- - -- SPARE 32 33 B FLUORESCENTS 1.136 1.136 B - -- - -- SPARE 34 35 SPARE - -- - -- C - -- - -- SPARE 36 37 SPACE - -- - -- - -- A ---- - -- -- -SPACE 38 39 SPACE - - -- - -- B - -- - -- -- -SPACE 40 41 SPACE _ -- - -- - -- C -- -- - -- -- -SPACE 42 No. Ckt. Z Zone L Load Description S Brkr Brkr N N.E.C. A Actual P Phase A Actual N N.E.G. B Brkr B Brkr Load Description Z Zone f fit 1 C CASHWRAP REC L LO 1 1.100 1 1.100 A A - - -- - - -- S SPARE 2 2 3 C CASHWRAP REC L LO 1 1.100 1 1.100 B B 0 0.400 0 0.400 L LO S SENSORMATIC 4 4 5 B BACKWRAP REC L LO 0 0.720 0 0,720 C C 0 0.360 0 0.360 L LO S SOUND SYSTEM 6 6 7 T TELEPHONE L LO 0 0.360 0 0.360 A A 1 1.500 1 1.500 L LO W WATER HEATER 8 8 9 S SPARE - - -- - - -- B B 0 0.360 0 0.360 P PHOTO BOOTH 1 10 11 S SALES RECEPT 0 0.720 0 0.720 C C 0 0.500 0 0.500 L LO F FIRE ALARM 1 12 13 S SPARE - - --` - - -- A A 0 0.360 0 0.360 L LO M MANAGER'S DESK 1 14 15 N NS RECEPT 0 0.820 0 0.820 B B 0 0.500 0 0.500 L LO L LTG. CTRL 1 16 17 S SALES RECEPT 0 0.540 0 0.540 C C 0 0.360 0 0.360 L LO C COMPUTER 1 18 19 S SPARE - - -- - - -- A A - - -- - - -- S SPARE 2 20 21 S SPARE - - -- - - -- B B - -- -- - - -- S SPARE 2 22 23 S SPARE _ _--- - - -- C C - - -- - - -- S SPARE 2 24 25 S SPACE - - -- - ---- - - -- A A - - -- - - -- - -- -SPACE 2 26 27 S SPACE - -- -- - - -_ - - -- B B - - -- - - -- - -- -SPACE 2 28 29 S SPACE - - -- - - -- - - -- C C - - -- - - -- - -- -SPAN 3 30 Brkr N.E.C. Actual Actual N.E.C. Brkr Brkr hat. Zone Load Description Size Phase Size Load Description Zone No. KW KW KW KW Opts A I No. 1 2.138 2.138 A 7.175 9.075 t 2 3 VAV -1 20/3 10 2.138 2.138 B 7.106 8.556 LO 70/3 } TRANSFORMER ! 4 y 5 2.137 2.137 C 7.000 10.450 � 6 7 2.138 2.138 A - -- - -- -- -SPACE 8 9 VAV -2 i 20/3 10 2.138 2.138 B - --- -- - - -- - SPACE 10 11 2.137 2.137 C SPACE 12 13 SPACE - -- - -- - -- A - -- - -- -- -SPACE 14 15 SPACE - -- - -- -- -- B ---- - -- -- -SPACE 16 17 SPACE - -- - -- - -- C - -- - -- -- -SPACE 1 18 A8' LIGHTING CONTACTOR "A" (QTY. AND POLES AS REQUIRED) FURNISHED BY T.S.P., INC. AND INSTALLED BY ELECTRICAL CONTRACTOR. REFER TO PANEL SCHEDULE ZONE LEGEND FOR CIRCUITS TO BE CONTROLLED. NEMA 1 LIGHTING CONTACTOR ENCLOSURE FURNISHED BY T.S.P., INC. AND INSTALLED BY ELECTRICAL CONTRACTOR ON WALL. 7 -DAY. 24 -HOUR DIGITAL TIME CLOCK IN NEMA 1 ENCLOSURE ZONE A ZONE B ZONE C LIGHTING ZONE LEGEND STOREFRONT LIGHTS SHOW WINDOW LIGHTS SIGN(S) SALES FLOOR TRACK LIGHTING LIGHTING CONTROL DIAGRAM LIGHTING CONTACTOR CONTROL SWITCH LOCATED BY ELECTRICAL PANELS FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR (TYP. FOR ZONE "B" AND "C"). LIGHTING CONTACTOR "B" AND "C" (QTY. AND POLES AS REQUIRED) FURNISHED BY T.S.P., INC. AND INSTALLED BY ELECTRICAL CONTRACTOR. REFER TO PANEL SCHEDULE ZONE LEGEND FOR CIRCUITS TO BE CONTROLLED. CONNECT CONTACTOR COIL TO LIGHTING CONTROL CIRCUIT. VOTES: FIXTURE LABELED "NL/EM" IS TO BE PROVIDED WITH A "EL4" EMERGENCY BALLAST a "W" INDICATES WALL MOUNTED & "C" INDICATES CEILING MOUNTED. SEE ARCHITECTURAL LIGHTING PLAN FOR MOUNTING HEIGHTS. 04 FIXTURE LABELED "NL/EM" IS TO BE PROVIDED WITH AN EMERGENCY BALLAST INDICATES FIXTURE TO BE SUPPLIED /INSTALLED WITH BLACK TRIM RING WHERE NOTED ON PLANS. NOTE: TRIM RINGS SHALL BE PAINTED TO MATCH ADJACENT CEILING COLOR AS REQUIRED. Panelboard Panel Type NEMA Type Enclosure _ t Notes • Ail circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted. Actual Load Totals: 0A 11.451 kw N.EC. Connected Totals 0A 13.351 kw 0B 11.382 -kw 0C 11.2_74 kw Total 34.107 kw Voltage 277/480 Phase Wire 4 AIC Rating 14.000 Mains 225 AMP MLO Mains Rating 225 AMP Mounting SURFACE Options Note 0B 12.832 kw 0C 14.724 kw Total 40.907 kw Breaker Op tions AS - Powerlink AS Breaker LO - Handle lock --off device ST - Shunt Trip Type AUX - Auxiliary Contacts PA - Handle Padlock Attachment GFCI - Ground Fault Circuit Interrupter HACR - Heating, A/C & Refrigeration Parma Wig Scheme (3 -Ile) Panelboard A Voltage 120/208 Panel Type AQ Mains 90A -3P MCB NEMA Type Enclosure 1 Mounting SURFACE Notes •All circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted Breaker Options: AS - Powerlink AS Breaker 1.0 - Handle lock -off device Actual Load Totals 0A 3.855 kw N.E.C. Connected Totals: 0A 5.755 kw ST - Shunt Trip Type AUX - Auxiliary Contacts PA - Handle Padlock Attachment GFCI - Ground Fault Circuit Interrupter HACR - Heating, A/C & Refrigeration 06 3.926 kw 0C 3.800 kw Total 11,581 kw LANDLORD NOTE: STOREFRONT SIGNAGE AND LIGHTING TIMECLOCK'S SHALL BE SET TO MALL'S OPERATING HOURS. LANDLORD NOTE: TENANT'S ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL AN IDENTIFICATION NAMEPLATE ON TENANT'S MAIN DISCONNECT SWITCH IN LANDLORD'S SWITCHBOARD. NAMEPLATE'S SHALL BE 1/8" THICK PLASTIC, BLACK ON WHITE AND ETCHED LETTERS. THE MINIMUM SIZE SHALL BE 1" THICK WITH ONLY THE TENANT'S SPACE NUMBER ENGRAVED ON SUCH, PERMANENTLY AFFIXED. 200A -3P CIRCUIT BREAKER, FURNISHED AND INSTALLED BY LANDLORD AT THIS ELECTRICAL CONTRACTOR'S EXPENSE, TO REMAIN AND BE REUSED. VERIFY EXACT REQUIREMENTS WITH LANDLORD IN FIELD PRIOR TO BID AND INCLUDE ALL COSTS IN BID. 013 5.376 kw 0C 7.250 kw Total 18.381 kw Phase 3 Wire 4 AIC Rating 10.000 Mains Rating 225 AMP Options Note LANDLORD PROVIDED 200A -3P FUSED DISCONNECT SWITCH WITH 200 AMP FUSES, FURNISHED AND INSTALLED BY LANDLORD AT THIS ELECTRICAL CONTRACTOR'S EXPENSE, TO REMAIN AND BE REUSED. ELECTRICAL CONTRACTOR SHALL RELOCATE SWITCH AND EXTEND EXISTING INCOMING SERVICE CONDUCTORS AND CONDUIT AS NECESSARY. VERIFY EXACT REQUIREMENTS WITH LANDLORD IN FIELD PRIOR TO BID AND INCLUDE ALL COSTS IN BID. LEASE LINE Zone Legend: LIMITED TOO SPACE METER, FURNISHED AND INSTALLED BY LANDLORD AT THIS ELECTRICAL CONTRACTOR'S L .., EXPENSE, TO REMAIN AND BE I I I REUSED. VERIFY EXACT 1 1i REQUIREMENTS WITH LANDLORD 1 IN FIELD PRIOR TO BID AND INCLUDE ALL COSTS IN B1D. L #4 THW GROUND TO BUILDING STEEL BY ELECTRICAL CONTRACTOR 1 NEW 45 KVA STEP -DOWN XFMR. FLOOR MOUNTED, 480 VOLT, 3- PHASE, 3 -WIRE PRIMARY, 120/208 VOLT, 3- PHASE, 4 -WIRE SECONDARY. Panelboard Panel Type NEMA Type Enclosure • All circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted. Actual Load Totals: 0A 3.320 kw 08 3 180k 0C 3.200 kw Total 9.700 kw 4 #3/0 THHN AND 1#4 GROUND IN A NEW 2" CONDUIT FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. 4 #3/0 THHN AND 1#4 GROUND IN A 2" CONDUIT, FURNISHED AND INSTALLED BY LANDLORD AT THIS ELECTRICAL CONTRACTOR'S EXPENSE, TO REMAIN AND BE REUSED. VERIFY EXACT REQUIREMENTS WITH LANDLORD IN FIELD PRIOR TO BID AND INCLUDE ALL COSTS IN BID. 3 #4 THHN AND 1 #8 GROUND IN A 1" CONDUIT FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. Voltage 120/208 Phase 3 Wire Mains 50A -3P MCB Mains Rating 125 AMP Mounting SURFACE Options AS - Powerlink AS Breaker 10 - Handle lock -off device N.E.C. Connected Totals: 0A 3.320 kw ST - Shunt Trip Type 03 AUX - Auxiliary Contacts OC PA - Handle Padlock Attachment GFCI - Ground Fault Circuit Interrupter HACR - Heating, A/C & Refrigeration PNL "B" 120/208V 30, 4W 50 AMP M.C.B. 3.180 kw 3.200 kw Total 9.700 kw POWER RISER DIAGRAM GENERAL NOTES Breaker Options: ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXACT K.A.I,C, RATING OF LANDLORDS DISTRIBUTION EQUIPMENT, FURNISH AND INSTALL LIMITED TOO'S SYSTEM TO MATCH. ELECTRICAL CONTRACTOR TO BALANCE TRANSFORMER TO SUPPLY 120V±3% AFTER ALL CONNECTIONS ARE MADE AND RUNNING. PROVIDE BALANCE SHEET TO TSP CONSTRUCTION MANAGER AT PUNCHLIST. PNL "A" 120/208V 30, 4W 90 AMP M.C.B. 4 #6 THHN AND 1#8 GROUND IN A 1" CONDUIT FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. 4 AIC Rating 10.000 HVAC CIRCUIT BREAKERS SHALL BE "HACK" TYPE WHERE REQUIRED BY EQUIPMENT NAMEPLATE PER N.E.C. ELECTRICAL CONTRACTOR SHALL BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT TO 7% ( +) BETWEEN PHASES: A /B, B /C. A/C REGARDLESS OF CIRCUITING INDICATED. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.C. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRI11P.MEN T. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. CEILING LIGHTING CONTACTORS FOR CONTROL OF LIGHTING. CONTACTORS CONTROLLED BY 7 -DAY, 24 -HOUR DIGITAL TIME CLOCK AND LIGHT SWITCH. SEE 4 #2 THHN AND 1#8 GROUND IN A 1 1/4" CONDUIT FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. FLOOR a 0 W N w J w 1 co J 4 0 2 0 w J W w 0 0) z z z IJ ca. ED -2 L0 0 co qicr 0 z m J LLI z Q Y CC a z M N M W cc 2 0 1 OC 3 0 W 0 Z 1 co 7HE ENGINEER ASSUMES NO RESPONSIBILITY OR LIABILITY FOR THE USE OF THESE PLANS FOR ANY PROJECT OTHER THAN SPECIFICALLY AUTHORIZED BY THEM AND SIGNED AND SEALED FOR SUCH SPECIFIC LOCATION IN THE STATE SHOWN ON THE SEAL THIS BUILDING USE IS ONLY APPIJCASLE IN AREAS MEETING THE STATED DESIGN CRITERIA. HBK # 07164 DRAWING NUMBER: A. NOTE B. GENERAL REQUIREMENTS C. TEMPORARY LIGHT AND POWER D. CODES G. GUARANTEE DIVISION 16 - ELECTRICAL SECTION 16000 BASIC ELECTRICAL REQUIREMENTS 1. THE ABBREVIATION T.S.P. WHEREVER IT APPEARS IN THESE ELECTRICAL DRAWINGS, SHALL REFER TO 'TWEEN BRAND STORE PLANNING, INC.'. ANY REFERENCE TO TENANT'S, OR LIMITED TOO'S CONSTRUCTION MANAGER OR FURNISHED BY ANY OF THE ABOVE REFERS TO T.S.P. 2_ DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 16. 3. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF HIS WORK AND THE WORK OF HIS SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE HIS SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 4. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF HIS WORK AND THE WORK OF HIS SUBCONTRACTORS WORK TO COMPLY WITH THE T.S.P. SCHEDULE AND THE PROJECT COMPLETION DATE_ 5. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTOR'S BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK. 6. REFER TO RESPONSIBILITY SCHEDULE ON THE ELECTRICAL DRAWINGS FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT BID. 1. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE COMPLETE ELECTRICAL SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD, POWER COMPANY OR T.S.P. SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH LANDLORD, POWER COMPANY AND T.S.P. CONSTRUCTION MANAGER AS REQUIRED. FURNISH AND INSTALL FQUIPMENT THAT IS RATED FOR AVAILABLE FAULT CURRENT LEVELS. BURNISH AND INSTALL "CABLE LIMITERS' iF NECESSARY TO LIRIT FAULT CURRENT. FIELD VERIFY THE EXACT TYPE, SIZE, LOCATION, REQUIREMENTS, ETC. OF EXISTING POWER AND TELEPHONE FACILITIES PRIOR TO SUBMISSION OF BID. 2. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. 3. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE PROVIDED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH 15 OBVIOUSLY NECESSARY TO COMPLETE•THE WORK OR WHICH 15 USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, .SHALL BE PROVIDED AS PART OF CONTRACT. 4. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS NOTED OTHERWISE. 5. ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT_ 6. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING, OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK UNDER THIS DIVISION. CUTTING SHALL HAVE PRIOR APPROVAL BY T.S.P. CONSTRUCTION MANAGER AND THE LANDLORD. PATCHING IS TO MATCH SURROUNDING SURFACES. 7. THE ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. 1. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL TEMPORARY WIRING AND RELATED GROUND FAULT INTERRUPTION PROTECTION FOR LIGHT A D prAER-F°a -i-L WRAC -TORS AND IS RE SL JR ITS REMOVAL. 2. THE GENERAL CONTRACTOR SHALL PAY FOR ALL ELECTRICITY PRIOR TO STORE MERCHANDISING AND INCLUDE COST IN BID. 1. ALL WORK SHALL BE PERFORMED IN A NEAT AND PROFESSIONAL MANNER AND CONFORM TO THE LATEST ADOPTED EDITION OF THE NATIONAL ELECTRICAL CODE, LANDLORD'S CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES, AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS_ THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY T.S.P. TO THE CONTRACTOR. E. LICENSES, PERMITS, INSPECTIONS & FEES 1. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO HIS WORK. 2. FURNISH TO T.S.P. CONSTRUCTION MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF PROJECT. F. TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING, THROUGH SHOP DRAWING SUBMITTAL PROCESS, BY T.S.P.'S CONSTRUCTION MANAGER /ENGINEERING MANAGER PRIOR TO ACCEPTANCE. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. 2. GENERAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO T.S.P.'S CONSTRUCTION MANAGER FOR APPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS FOR T.S.P. CONSTRUCTION MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP OF THE GENERAL CONTRACTOR AND SUB - CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BE TAKEN_ 1_ THIS CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK PROVIDED UNDER HIS CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT HIS OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL, OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY T.S.P.'S CONSTRUCTION MANAGER /ENGINEERING MANAGER. EXTENDED WARRANTIES ARE SPECIFIED WITH INDIVIDUAL EQUIPMENT. • 2_ T.S.P., INC_ SHALL PROVIDE A COMPLETE 12 -MONTH WARRANTY FOR ALL PARTS ON EQUIPMENT PROVIDED BY T.S.P.; INC. AND T.S.P.'S VENDORS. THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM, AND AS SUCH, NO ADDITIONAL MONIES SHOULD BE INCLUDED IN THE BID. H. RECORD DRAWINGS 1. THIS CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: A. LOCATION OF JUNCTION BOXES AND RECEPTACLES. B. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. C_ SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. 2. AT COMPLETION OF PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. ONE COPY OF DRAWINGS STAMPED 'DO NOT REMOVE" SHALL BE PLACED IN DRAWING TUBE LOCATED NEXT TO THE ELECTRICAL PANELS (SEE ARCHITECTURAL DRAWINGS FOR LOCATION). I. DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATICAL AND INDICATE THE GENERAL LOCATION AND INTENT OF THE ELECTRICAL' SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING PRIOR TO SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE T.S.P.'S CONSTRUCTION MANAGER IN WRITING OF ANY VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF THE BID. OTHERWISE, T.S.P. CONSTRUCTION MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. 2. THE LOCATION OF OUTLETS AND EQUIPMENT SHOWN ON THE DRAWINGS ARE APPROXIMATE AND SCHEMATIC IN NATURE. T.S.P. SHALL HAVE THE RIGHT TO RELOCATE ANY OUTLETS OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. - 1= F -1 i•r •i •I - 1 I? : r .�_ -. 4; le • _ FOR AN INCLUDE IN HI REQUIRED TO KEEP THE SERVICE IN OPERATION. CO CONSTRUCTION MANA PRIOR TO ELE r 1. 1 IS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINAT DEMOLITION OF EXISTING WORK AND THE DEMOLITION P BY GENERAL CONTRACTOR. COORDINATE WITH THE G RAL CONTAAC A. ANY EXISTING EQUIPMENT TO BE LEFT I CT AND ADVISE T. .'.'S CONSTRUCTION MANAGER AT TIME : BID. 2. THIS CONTRACTOR . .L INCLUDE, AND WIL �E HELD RESPONSIBLE FOR, THE REMOVAL 1 ALL EXISTING CON .IT, FIRE ALARM SYSTEM, SNITCH GEAR, PITCH Pe- ETS AND E` - RENT ETC. UNLESS SPECIFICALLY NOTED OTHERWISE. •NTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED -.::.•ZONED EQUIPMENT, CONDUIT AND SWITCH GEAR PRIOR TO REMO .1 PITCH POCKETS SHALL BE MINED AND THE ROOF P HED, A EQUIRED BY THE LANDLORD. ALL EXTRANEOUS ITEMS THE SPACE :' ON THE ROOF NOT APPLICABLE TO THE WORK MUST BE R •SVED AND ROOF/WALL /FLOG' - ATCHED /REPAIRED TO LIK EW CONDITION. EXISTING AB•+ONED CONDUIT OR EQUIPMENT I HE FLOOR, EMBEDDED CONCRETE, OR OTHERWISE INACCESSI: , ARE TO BE CUT OFF D SEALED BELOW OR WITHIN FLOOR OR ORAL EVEL WHEN THEY •1'E NOT TO BE REUSED IN THIS PROJECT. IF REQb RED BY ...LORD OR CODES, ABANDONED CONDUIT MUST BE REMOVED 'TINT OF ORIGIN. CONFIRM EXTENT OF DEMOLITION PRIOR TO D AND INCLUDE IN PROPOSAL. L. SLEEVES 1. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE 'RTE' FOAM, "3M' FIRE RATED SEALANTS OR EQUAL, 50 AS TO RETAIN THEIR FIRE RATING. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL CONDUIT, SLEEVES SHALL BE ND. 22 U.S.G. GALVANIZED STEEL MINIMUM. M. HANGERS 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, WIRE, UNISTRUT, C- CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF N10RK. 2. RS ALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, 3T mil TO OTHER CONDUIT OR PIPING. HANGERS UPPER ATTACHMENT MUST BE SUPPORTED FROM THE TOP OF THE BAR JOIST. HANGING FROM METAL DECK IS NOT PERMITTED. WHERE INTERFERENCES OCCUR, IN ORDER TO SUPPORT CONDUIT, THE CCTITRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS 11iHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, JUNCTION BOXES, ACCESS DOORS, OTHER EQUIPMENT SERVICE REQUIREMENTS AND /OR OTHER TRADES_ HANGER TYPES AND INSTALLATION METHODS ARE SUBJECT TO LANDLORD CRITERIA. N. FINAL ELECTRICAL INSP CTIONS 1. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, T_S_P. SHALL HAVE AN INDEPENDENT ELECTRICAL CONTRACTOR INSPECT THE FINISHED ELECTRICAL INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PLANS, SPECIFICATIONS AND CODES. THE ORIGINAL ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED UP TO PLAN AND SPECIFICATION REQUIREMENTS. END OF SECTION 16000 A. SCOPE OF WORK NOT APPLICABLE) ED STORE CONSTRUCTION, THIS CONT ALL NECESSARY ELECT ATING DIVISION 16 - ELECTRICAL SECTION 16050 BASIC ELECTRICAL MATERIALS AND METHODS IS TO SERVICE CHANGES OF THE STORE'S ELECTRIC MUST SCHEDULE WITH T.S.P.'S !TING) ONE WEEK ERS, GENERAL D LANDLORD DOWN OF THE POS, CASH 1 , TELEPHONE OR FIRE ALARM SYSTEMS. CTOR AT TIME OF BID IF ANY CONFLICTS EXIST. -NOT APPLICABLE} OF IDED 1. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE ELECTRICAL SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: A. A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM INCLUDING THE INSTALLATION OF T.S.P. PROVIDED PANELBOARDS, SAFETY AND DISCONNECT SWITCHES, MOTOR STARTERS, LIGHTING CONTACTORS, LIGHTING AND TRANSFORMERS. IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO INCLUDE IN HIS BID FOR PROVIDING SERVICE EQUIPMENT NECESSARY FOR TIE -IN TO LANDLORD'S DISTRIBUTION EQUIPMENT OR TO OBTAIN SERVICE FROM LOCAL UTILITY COMPANY. REFER TO ELECTRICAL RESPONSIBILITY SCHEDULE AND ELECTRICAL POWER RISER DIAGRAM FOR ADDITIONAL INFORMATION. B. CONTRACTOR MUST ALSO INCLUDE IN BID ALL NECESSARY MATERIALS REQUIRED TO COMPLETE THE SYSTEM INCLUDING, BUT NOT LIMITED TO. FEEDERS, BRANCH CIRCUITS, JUNCTION BOXES, OUTLET BOXES, WIRING DEVICES, COVERPLATES, CONDUITS, ETC. C. METERING AND CURRENT TRANSFORMERS AS REQUIRED BY DRAWINGS, T.S.P., UTILITY COMPANY, AND /OR LANDLORD. D. THE WIRING OF MECHANICAL EQUIPMENT AS OUTLINED ON THE BID SET DRAWINGS AND IN THE SPECIFICATIONS. WORK SHALL INCLUDE WIRING OF ALL STARTERS, DISCONNECTS, AND POWER WIRING OF MECHANICAL EQUIPMENT EXCEPT AS SPECIFICALLY NOTED OTHERWISE. ALL LOW VOLTAGE (24 VOLT) TEMPERATURE CONTROL WIRING SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR UNLESS NOTED SPECIFICALLY ON DRAWING. E_ INSTALLATION OF LIGHT FIXTURES AND LAMPS AS SHOWN ON THE DRAWINGS INCLUDING ALL DEVICES, EQUIPMENT, ETC. REQUIRED FOR MOUNTING. F_ A COMPLETE CONDUIT SYSTEM FOR TELEPHONE /DATA INCLUDING TERMINAL BOARD, BRANCH CONDUITS, OUTLET BOXES, PULL WIRES, GROUND CONDUCTORS, COVER PLATES, ETC. OR AS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. G. A COMPLETE EMERGENCY AND EXIT LIGHTING SYSTEM AS SHOWN ON THE DRAWINGS. H. TEMPORARY SERVICE AS INDICATED IN THE SPECIFICATIONS, INCLUDING IT'S REMOVAL. 1. FINAL CONNECTIONS TO ALL SIGNS, CORNICE LIGHTING, CASE LIGHTING, ETC. AS SHOWN ON DRAWINGS. J. INSTALLATION AND WIRING OF SPEAKERS, AMPLIFIERS, CONDUIT AND FINAL CONNECTIONS FOR SOUND SYSTEM AS SHOWN ON DRAWINGS. K. SMOKE /FIRE ALARM WIRING, DEVICES AND CONDUIT, AS SHOWN OR DESCRIBED ON DRAWINGS OR AS NECESSARY TO MEET LANDLORD, STATE, LOCAL, INSURANCE AND FIRE DEPARTMENT REQUIREMENTS. L. INSTALLATION OF CONDUITS STUBBED TO ABOVE CEILING FOR HVAC AND /OR LIGHTING CONTROL PANEL. ALSO, ANY ADDITIONAL CONDUIT FOR HVAC CONTROL EQUIPMENT WHERE PLENUM RATED CABLES ARE NOT PERMITTED. REFER TO DRAWING M-1. 2. WORK NOT INCLUDED THE FOLLOWING ITEMS OF ELECTRICAL CONSTRUCTION ARE NOT INCLUDED IN THIS CONTRACT: A. 24 VOLT TEMPERATURE CONTROL WIRING UNLESS NOTED OTHERWISE. B. TELEPHONE INSTRUMENTS AND WIRING UNLESS NOTED OTHERWISE. C. DATA LINES WIRING UNLESS NOTED OTHERWISE. 3. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, FIRE PROTECTION, MECHANICAL AND PLUMBING PLANS, SHOP DRAWINGS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE ELECTRICAL SYSTEM, MATERIALS AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. B. CONDUIT 1_ THIS CONTRACTOR SHALL FURNISH AND INSTALL ALI CONDUITS SERVING ALL EQUIPMENT, INCLUDING BUT NOT LIMITED TO, LIGHTING, RECEPTACLES, HEATING, AIR CONDITIONING, PLUMBING EQUIPMENT, TELEPHONE, DATA, SPEAKERS, AND ELECTRICAL EQUIPMENT. 2. ALL CONDUITS SHALL BE GALVANIZED IMC OR EMT UNLESS OTHERWISE SPECIFIED IN SPECIFICATIONS OR ON DRAWINGS. ALL CONDUIT 15 TORE UL LABELED. EMT CONNECTORS SHALL BE STEEL COMPRESSION OR SET SCREW TYPE. CONDUIT UNDER SLAB ON GRADE SHALL BE RIGID STEEL, OR SCHEDULE 40 PVC WITH RIGID STEEL ELLS WHERE PEI+MIITT£D BY LANDLORD OR CODE. 3. MINIMUM SIZE OF CONDUIT SHALL BE 1/2" FOR INDIVIDUAL LIGHTING FIXTURE CONNECTIONS OR TO INDIVIDUAL LIGHT SWITCHES (IF ACCEPTABLE BY THE LANDLORD AND LOCAL CODE OFFICIALS) AND 314 FOR ALL OTHER LOCATIONS. IF HVAC CONTROL WIRING IS REWIRED TO BE RUN IN CONDUIT, IT SHALL BE A MINIMUM OF 3/4 ' UNLESS NOTED OTHERWISE ON DRAWINGS. ALL 1N /UNDER FLOOR CONDUIT SHALL BE OF MINIMUM 3/4" SIZE. 4. SUPPORT ALL CONDUIT, INCLUDING SEISMIC AND SWAY BRACING, IN ACCORDANCE WITH THE NEC AND LOCAL CODES. 5_ GEIIERALLY, ALL CONDUIT SHALL BE CONCEALED EXCEPT FOR UNFINISHED AREAS, SUCH AS EQUIPMENT ROOMS. EXPOSED CONDUIT SHALL BE ALLOWED ONLY AS NOTED ON PLAN AND AS APPROVED BY T.S.P.'S CONSTRUCTION MANAGER. PAINTING OF CONDUITS, NOTED ONIIXiAWINGS OR SPECIFICATIONS WILL BE BY GENERAL CONTRACTOR. 6. FLEXIBLE METAL CONDUIT OR MC TYPE CABLE A FLEXIBLE CONDUIT OR MC TYPE CABLE SHALL BE USED FOR THE FOLLOWING APPLICATIONS ONLY (MAX. LENGTH TO BE 6 FT): 1. FINAL CONNECTIONS TO MOTORS. 2. FINAL CONNECTIONS INTO AND OUT OF THE TRANSFORMER. 3. FINAL CONNECTIONS TO VIBRATING EQUIPMENT. 4. INTER - CONNECTIONS BETWEEN ALL LIGHT FIXTURES. (NOT TO INCLUDE HOMERUN FROM FIXTURE OR DEVICE TO PANELBOARD, WHICH MUST BE RIGID). 5. FINAL CONNECTIONS WHERE RIGID CONDUIT IS NOT PRACTICAL. 6. IN WALLS (FOR LIGHT SWITCHES AND 120 VOLT POWER RECEPTACLES AND HVAC CONTROL EQUIPMENT). B. FLEXIBLE METAL CONDUIT OR MC TYPE CABLE MUST BE THE SAME SIZE AS THE IMC OR EMT CONDUIT TO WHICH IT IS CONNECTED. BOTH THE FLEXIBLE METAL CONDUIT AND IT'S FITTINGS ARE TO BE LISTED FOR GROUNDING. A GREEN GROUNDING CONDUCTOR SHALL BE INSTALLED. ALL CONNECTORS ARE TO BE OF A NEMA APPROVED TYPE. C. THE USE OF ROMEX, BX, ETC. IS NOT PERMITTED. D. CONNECTION TO OUTDOOR EQUIPMENT MUST BE WEATHERPROOF, I.E. LIQUIDTIGHT OR SEALTIGHT. 7_ PROVIDE PULL-WIRE IN ALL EMPTY CONDUITS EXCEPT AS NOTED OTHERWISE ON DRAWINGS. 8_ HOME RUNS AND MAIN CONDUIT RUNS ARE TO BE HELD TIGHT TO STRUCTURE ABOVE OR AS REQUIRED TO ALLOW PROPER SERVICE ACCESS AND OTHER TRADES WORK. CONDUIT MUST BE TRAPEZED TO ALLON 3 FEET MINIMUM CLEARANCE ABOVE CEILING. ALL CONOUITSRNRF51 BE S 91E'il Fe NEC AND LOCAL 4 DES. C. OUTLET BOXES 1. ALL OUTLET BOXES SHALL BE GALVANIZED PRESSED STEEL OF THE STANDARD KNOCKOUT TYPE. NO ROUND OUTLET BOXES SHALL BE FI HATTED, EXCEPT AS SPECIFICALLY NOTED ON DRAWINGS. COIh1LLALED BOXES SHALL NOT BE LESS THAN 4' SQUARE AND 1 1/2' DEEP, WITH PLASTER RINGS. 2. ALL KNOCKOUT BOXES, UPON WHICH LIGHTING FIXTURES ARE TO BE INSTALLED, SHALL BE EQUIPPED WITH 3/8' FIXTURE STUDS. 3. EXTERIOR BOXES SHALL BE CAST RUST - RESISTING METAL WITH GASTED COVERS. 4_ MALL BOXES RIGIDLY FROM BUILDING STRUCTURE AND SUPPORT DEPENDENTLY OF THE CONDUIT SYSTEM. ALSO PROVIDE SUITABLE BOX EXTENSIONS TO EXTEND BOXES TO FINISHED FACES OF FLOORS, CEILINGS, WALLS ETC. ALL OUTLET BOXES TO BE PROVIDED WITH CAM "QUICK -MOUNT BOX SUPPORT' TO MINIMIZE THE DEFLECTION THAT OCCURS WHEN PLUGGING /UNPLUGGING INTO THESE DEVICES. 5_ UNLESS OTHERWISE NOTED ON DRAWINGS OR OTHERWISE REQUIRED BY THE NATIONAL ELECTRICAL CODE, HANDICAP CODES OR LOCAL CODES, CUTLET HEIGHTS SHALL BE AS FOLLOWS: E_ WIRING A SWITCH HEIGHT 48' FROM FINISHED FLOOR TO CENTERLINE OF OUTLET. B. CONVENIENCE OUTLETS: SALES: HORIZONTALLY MOUNTED IN BASEBOARD BENEATH CABINETS, AS SHOWN ON DRAWINGS, OR AS REQUIRED BY LOCAL CODES. NON- SALES: 18" FROM FINISHED FLOOR TO CENTERLINE OF OUTLET C_ TELEPHONE OUTLETS SHALL BE LOCATED AS NOTED ON DRAWINGS. D. JUNCTION AND PULL BOXES 1. THE PLANS INDICATE ONLY SCHEMATIC ROUTINGS FOR CONDUIT RUNS. THIS CONTRACTOR SHALL FURNISH AND INSTALL ADDITIONAL BOXES WHERE REQUIRED BY FIELD CONDITIONS OR BY CODE. 2. BOGIES AND COVERS SHALL BE GALVANIZED STEEL OF CODE GAUGE SIZE. 3. INSTALL BOXES RIGIDLY SUPPORTED FROM THE BUILDING STRUCTURE AND SUPPORTED INDEPENDENT OF THE CONDUIT SYSTEM. 4_ ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DR1tWALL CEILINGS SHOULD BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS_ . 5. JUNCTION AND PULL BOXES MUST BE LABELED WITH CIRCUIT NUMBER IDENTIFICATION AND SYSTEM TYPE ON COVER. 1_ CONDUCTORS FOR FEEDERS AND BRANCH CIRCUITS SHALL BE COPPER AND THE AWG SIZE AND TYPE AS SHOWN ON DRAWINGS_ MINIMUM WIRE SIZE #12. THE CONDUCTORS SHALL BE 600 VOLT INSULATION, TYPE THW, THWN OR THHN. ELECTRICAL SPECIFICATIONS 2. !MINIMUM WIRE SIZE - 20 AMP BRANCH CIRCUIT SHALL BE AWG LISTED SIZE PER DISTANCE SHOWN BELOW. DISTANCE SHALL BE MEASURED FROM THE PANELBOARD CIRCUIT BREAKER TO THE FURTHEST OUTLET. A_ 112 LESS THAN 100 FEET B. #10 BETWEEN 100 -150 FEET C. #8 BETWEEN 150 - 250 FEET D_ 116 OVER 250 FEET 3. ON ALL 20 AMP BRANCH CIRCUITS, CONDUCTORS LARGER THAN 110 AWG SHALL BE REDUCED TO #10 AWG WITHIN 10 FEET OF PANEL HOARD AND DEVICE IN JUNCTION BOXES ON RATED TERMINAL STRIPS. 4. CONDUCTORS MAY BE STRANDED FOR SIZES #10 AWG AND LARGER. CONDUCTORS SIZE #12 SHALL BE SOLID (NOT STRANDED). 5. ALUMINUM CONDUCTORS ARE NOT PERMITTED, EXCEPT AT SERVICE ENTRANCE, WHERE REQUIRED BY LANDLORD. CONDUCTOR CONNECTION MUST BE PER MANUFACTURER'S REQUIREMENTS. CONTRACTOR MUST ADVISE GENERAL CONTRACTOR AND T.S.P.'S CONSTRUCTION MANAGER MEN USED. 6. ALL WIRING SHALL BE IN CONDUIT, UNLESS SPECIFICALLY NOTED OTHERWISE (IE. LOW VOLTAGE PLENUM RATED WIRE). 7. THE USE OF SHARED NEUTRALS 1S REQUIRED FOR LIGHTING CIRCUITS AND SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND LOCAL CODES. ALL OTHER EQUIPMENT REQUIRING A NEUTRAL CONDUCTOR SHALL HAVE A DEDICATED FULL SIZE NEUTRAL. 8. THE USE OF ROMEX, BX, ETC. IS Q PERMITTED. 9. WIRE CONNECTORS SHALL BE EQUAL TO 'SCOTCH LOCK' FOR #8 AWG WIRE AND SMALLER AND EQUAL TO T & B 'LOCKTIGHT" FOR #6 AWG AND LARGER. 10. ALL WIRING TO BE COLOR -CODED AS FOLLOWS: 120/208 VOLT SYSTEM NEUTRAL - WHITE PHASE A OR L1 - BLACK PRASE B OR L2 - RED PHASE C OR L3 - BLUE GROUND - GREEN F. WIRING DEVICES 277/480 VOLT SYSTEM NEUTRAL - GRAY PHASE A OR Li - YELLOW PHASE B OR L2 - ORANGE PHASE C OR L3 - BROWN GROUND - GREEN WITH YELLOW TRACER 1. THIS CONTRACTOR SHALL FURNISH AND INSTALL SWITCHES AND RECEPTACLES, UNLESS NOTED OTHERWISE, AS NECESSARY FOR A COMPLETE INSTALLATION. COLOR OF DEVICES AND PLATES SHALL BE SELECTED BY T.S.P. THE DEVICES SHALL BE OF THE TYPES AND RATINGS LISTED, OR EQUALS BY ARROW -HART, GENERAL ELECTRIC OR PASS 8: SEYMOUR. WEATHERPROOF GFI RECEPTACLES SHALL BE INSTALLED WHERE SHOWN ON DRAWINGS OR AS REQUIRED BY CODE. SINGLE POLE SWITCHES: 20AMP - 120-277V: HUBBELL 'I;BL -1221 " THREE WAY SWITCHES: 20AMP - 120 -277V: HUBBELL "HBL -1223" DUPLEX RECEPTACLES: 20AMP - 125V: LEVITON '5352" ISOLATED GROUND RECEPTACLES: 20AMP - 125V: LEVITON "5362 -IG" GROUND FAULT CIRCUIT INTERRUPTING RECEPTACLES: 20AMP - 125V: LEVITON '6899' 2. ALL DEVICE COVERPLATES SHALL BE PASS AND SEYMOUR SERIES 'RP" OR EQUAL BY EAGLE ELECTRIC MFG.00.. G_ HEATING, VENTILATING & AIR CONDITIONING, PLUMBING, AND FIRE PROTECTION WIRING 1. ELECTRICAL CONTRACTOR SHALL REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL ELECTRICAL WORK TO BE INCLUDED HIS BID. 2. ELECTRICAL CONTRACTOR SHALL DO ALL POWER WIRING, LINE VOLTAGE WIRING, AND LINE VOLTAGE CONTROL WIRING INDICATED UNDER THE HEATING, VENTILATION AND AIR CONDITIONING, PLUMBING AND FIRE PROTECTION SPECIFICATIONS AND DRAWINGS. THIS CONTRACTOR SHALL ALSO DO ALL INTERCONNECTING LINE VOLTAGE WIRING BETWEEN RELAYS AND SWITCHES AS REQUIRED. 4. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING CONDUIT FOR HVAC CONTROL WIRING WHERE REQUIRED BY CODE TO BE IN CONDUIT. REFER TO PLANS FOR REQUIREMENTS AND SIZE. 5_ REFER TO MECHANICAL DRAWINGS FOR AVAILABLE SCHEMATIC WIRING DIAGRAMS OF EQUIPMENT. H. SAFETY AND DISCONNECT SWITCHES 1. SAFETY AND DISCONNECT SWITCHES SHALL BE HEAVY DUTY TYPE, WICK -MAKE, QUICK -BREAK FUSED OR NON- FUSIBLE WITH RATINGS AN) SIZES AS NOTED ON PLANS AND REQUIRED BY CODES. 2. SNITCHES SHALL BE IKANIRRPROOF IN OUTDOOR LOCATIONS OR AS REQUIRED BY LOCAL CODES. DISCONNECT SWITCHES THAT-ARE INSTALLED AT HEATING, VENTILATING AND AIR CONDITIONING (HVAC) EQUIPMENT SHALL BE FUSED IF NOT PROTECTED WITH A 'HACR' BREAKER IN ACCORDANCE WITH THE EQUIPMENT'S NAMEPLATE AND MANUFACTURER'S REQUIREMENTS PER THE NATIONAL ELECTRICAL CODE, STATE AND LOCAL CODES. 3. AT SERVICE ENTRANCE, DISCONNECT SHALL BEAR THE WNI1FACTURER'S LABEL INDICATING THE EQUIPMENT IS UL RATED FOR APPLICATION IN ACCORDANCE WITH ALL CODES. 4. GENERAL ELECTRIC CR101/CR1062 MANUAL MOTOR STARTERS, LESS OVERLOAD PROTECTION HEATERS, ARE TO BE USED AS A DISCONNECTING MEANS ONLY WHERE INDICATED ON DRAWINGS FOR FRACTIONAL HORSEPOWER MOTORS ABOVE 1 1/2 HP AT 120 VOLTS AND 2 HP AT 240 VOLTS THAT DO NOT REQUIRE AUXILIARY CONTROL. MOTORS THAT ARE BELOW THE 1 HP AT 120 VOLTS, 2 HP AT 240 VOLTS, WATER HEATER AND ROLLING GRILLE'ARE TO BE PROVIDED WITH HUBBELL 'HBL -1221, OR 1222' AC SWITCH. 5. MANUFACTURER SHALL BE GENERAL ELECTRIC. J. GROUNDING NOT APPLICABLE) 1 • • I r � STARTERS SHALL BE PROVIDED WITH RES YPE CLOSELY MATCH MOTOR NAMEPLATE ; NG AND ICALLY HELD (MINIMUM SIZE , IN A NEMA 1 ED FOR ALL SING - E AND THREE PHASE TIC MOTOR OIERLO THAT SHALL BE EL ENCLOSURE) AND MOTORS RATED ABOVE 1 PROVIDE CONTROL DEVICES HRO-A, ETC.) IN START COORDINATE ALL C OL DEVICES WITH COMBINATION TER /DISCONNECT SWITCHES fUSIBL ITCHES AND ONLY USED WHERE INDICAT THAT ' •' . . AS RE FACTURER SHALL BE GENERAL ELECTRIC. IRE AUXILIARY CONTROL_ MARY CONTACTS, TRANSFORMERS, D FOR INTERLOCKS. ANICAL CONTRACTOR. L CONTAIN DRAWINGS 1. FURNISH AND INSTALL COMPLETE WIRED GROUNDING CONDUCTOR SYSTEM, #12 AWG MINIMUM, SIZED AND INSTALLED IN ACCORDANCE WITH THE LATEST ADOPTED EDITION OF THE NATIONAL ELECTRICAL CODE, STATE AND LOCAL CODES, THE LANDLORD'S TENANT CRITERIA AND AS NOTED IN THE SPECIFICATIONS AND AS INDICATED ON THE DRAWINGS. 2. ALL CONDUIT, INCLUDING FLEXIBLE CONDUIT, SHALL BE GROUNDED IDTH A GREEN GROUNDING CONDUCTOR. • 3_ GROUNDING CONNECTIONS MADE TO THE WATER PIPING SYSTEM SHALL BE COORDINATED WITH THE PLUMBING CONTRACTOR AND A BONDING JUMPER INSTALLED AROUND WATER METER PER CODES AND AS INDICATED ON DRAWINGS. 4_ ALL DEVICES SHALL BE BONDED TO THE CONDUIT SYSTEM. USE A BONDING JUMPER BETWEEN THE OUTLET BOX AND THE DEVICE GROUNDING TERMINAL. METAL -TO -METAL CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX IS NOT ACCEPTABLE AS A BOND FOR EITHER SURFACE MOUNTED BOXES OR FLUSH TYPE BOXES. ALL JUNCTION BOXES, OUTLET BOXES, AND PULL BOXES SHALL BE BONDED TO THE CONDUIT SYSTEM. 5. RUN A SEPARATE ISOLATED GROUNDING CONDUCTOR, #12 AWG MINIMUM, IN EACH CONDUIT FEEDING THE CASH WRAP, THE SENSORMATIC, HVAC CONTROL PANEL, AND OTHER COMPUTERIZED EQUIPMENT AS SHOWN ON DRAWINGS. 6. FOR PANEL FEEDERS, BOND THE GROUNDING CONDUCTOR TO THE CONDUIT, WHERE ENTERING AND LEAVING THE CONDUIT. THE GROUNDING CONDUCTOR SHALL BE COPPER WITH GREEN IDENTIFICATION AND SIZED PER N.E.C. 7. ALL ENCLOSURES AND NON- CURRENT CARRYING METAL PARTS ARE TO BE GROUNDED_ CONDUIT SYSTEM IS TO BE ELECTRICALLY CONTINUOUS. ALL LOCKNUTS MUST CUT THROUGH ENAMELED OR PAINTED SURFACES ON ENCLOSURES. WHERE ENCLOSURES AND NON- CURRENT CARRYING METAL PARTS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS WITH APPROVED CLAMPS. ALL GROUND CLAMPS SHALL BE "PENN - UNION' OR EQUAL, SIMILAR TO 'CPL" TYPE. K. DRY TYPE TRANSFORMERS 1_ TRANSFORMERS WHICH ARE NOT PAD MOUNTED SHALL BE SECURELY MOUNTED FROM THE BUILDING STRUCTURE, REINFORCED WALLS, OR AS NOTED ON DRAWINGS. USE ADDITIONAL VIBRATION ISOLATORS AT POINTS OF MOUNTING TO CUT VIBRATION NOISES. USE FLEXIBLE METALLIC CONDUIT WITH GROUNDING BUSHING FOR PRIMARY AND SECONDARY CONNECTIONS TO TRANSFORMER. TRANSFORMERS SHALL BE LOCATED, SET, MOUNTED AND CONNECTED IN SUCH A MANNER AS TO KEEP NOISE LEVELS WITHIN THE SURROUNDING AMBIENT NOISE LEVELS AND MAINTAIN ALL CODE REQUIRED CLEARANCES. 2_ TRANSFORMER SHALL BE QUIET TYPE CONSTRUCTION AND HAVE SIX (6) 2 1/2% TAPS, TWO (2) TAPS ABOVE AND FOUR (4) TAPS BELOW NORMAL PRIMARY RATING. 3. MANUFACTURER SHALL BE GENERAL ELECTRIC. L. PANELBOARDS 1. ALL PANELBOARDS SHALL BE FACTORY ASSEMBLED OF THE BOLTED CIRCUIT BREAKER TYPE WITH SOLID COPPER BUSSING, FULL SIZED COPPER NEUTRAL, 100% GROUND BUSSING, AND OVERALL HINGED /LOCKABLE DOOR. ALL CIRCUIT BREAKERS SHALL BE OF THE QUICK -MAKE AND QUICK -BREAK DESIGN, THERMAL - MAGNETIC TYPE,' TRIP FREE AND TRIP - INDICATING. ALL PANELS SHALL BE DEAD FRONT AND FLUSH OR SURFACE MOUNTED AS SHOWN. 2_ CONTRACTOR SHALL FURNISH AND INSTALL A TYPEWRITTEN DIRECTORY CARD OF THE CIRCUITS AND PLACE IN PANEL DOOR. 3. ALL PANELBOARDS PHASE AMPERAGE SHALL BE BALANCED TO WITHIN 7 PERCENT MAX. TO MIN. REARRANGE NON - LIGHTING BRANCH CIRCUITS AS REQUIRED AND NOTE CHANGES ON RECORD DRAWINGS. LIGHTING PANEL CIRCUIT BREAKERS MUST BE INSTALLED AND WIRED EXACTLY AS SHOWN ON DRAWINGS. 4_ PANELBOARDS MUST BE MOUNTED ON MINIMUM 3/4' A/D PLYWOOD AND PAINTED IN A COLOR TO MATCH THE SURROUNDING WALLS OR A COLOR AS REQUIRED BY LOCAL CODE. PLYWOOD SHALL EXTEND 1 FOOT MINIMUM BEYOND EDGE OF EQUIPMENT. 5_ PANELBOARDS SHALL HAVE A MINIMUM SHORT CIRCUIT CURRENT RATING AND LUG CONNECTIONS AS FOLLOWS: 120/208 VOLT PANELBOARDS: 10,000 A.I.C. 277/480 VOLT PANELBOARDS: 14,000 A.I.C. VERIFY ACTUAL A.I.C. SHORT CIRCUIT CURRENT REQUIREMENTS WITH THE LANDLORD OR UTILITY COMPANY PRIOR TO ORDERING EQUIPMENT. ALL LUG CONNECTIONS TO BE 75'C RATED. 6. MANUFACTURER SHALL BE GENERAL ELECTRIC. M. LIGHTING FIXTURES & LAMPS 1. THIS CONTRACTOR SHALL INSTALL ALL LIGHTING FIXTURES AND LAMPS AS SHOWN ON THE DRAWINGS. LIGHTING FIXTURES AND LAMPS ARE SUPPLIED BY T.S.P., UNLESS NOTED OTHERWISE. CONTRACTOR IS TO REPLACE ALL NON- WORKING LAMPS PRIOR TO MERCHANDISE DATE AND IS TO INCLUDE COST IN BID. 2. ALL RECESSED INCANDESCENT FIXTURES SHALL BE PROVIDED WITH APPLICABLE THERMAL PROTECTION. 3. WHERE FLUORESCENT FIXTURES ARE SPECIFIED, THEY SHALL BE PROVIDED WITH HIGH POWER FACTOR RAPID START BALLASTS, U.L. LISTED, C.B.M. CERTIFIED, AND E.T.L. APPROVED WITH EFFICIENCY FACTORS IN ACCORDANCE WITH THE ENERGY POLICY ACT OF 1992' AND ITS AMENDMENTS AS A MINIMUM. 4. THIS CONTRACTOR SHALL FURNISH ADDITIONAL AUXILIARY SUPPORT STEEL HANGER WIRES ADEQUATELY SIZED TO SUPPORT THE WEIGHT OF T E ; I XTU. RE FASTENED TO THE WILDING STRUCTURE (MINIMUM TWO PER FIXTURE) FOR ALL F1XTU ES IN LAY -IN CEILINGS AND OTHER FIXTURES AS REQUIRED BY THE LANDLORD AND LOCAL CODE OFFICIALS. 5. FURNISH AND INSTALL APPLICABLE FIRE RATED DRYWALL BOXES OVER RECESSED FIXTURES IN FIRE RATED CEILINGS AS REQUIRED BY CODES. FIELD COORDINATE AS REQUIRED TO AVOID CONFLICTS. N. LIGHTING CONTROLS 1 WHERE A LIGHTING CONTROL PANEL IS INDICATED ON THE DRAWINGS, IT WILL BE PROVIDED BY T.S.P. AND INSTALLED BY THE ELECTRICAL CONTRACTOR COMPLETE WITH CONDUIT. THE CONTROL PANEL SHALL BE PREPROGRAMMED AND COMPLETE WHEN SHIPPED TO THE .HOB SITE. THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE TO INSTALL THE PANEL AND PULL ALL WIRES AS DETAILED ON THESE DRAWINGS AND CIRCUITED EXACTLY AS DIAGRAMMED ON THE LIGHTING PLAN DRAWINGS. NO VARIATIONS TO THE CIRCUITING ARE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL BY T.S.P.'S ENGINEERING MANAGER. O. TELEPHONE DATA AND COMPUTER WIRING 1_ FURNISH AND INSTALL A SYSTEM OF CONDUIT RACEWAYS, OUTLET BOXES, PULL WIRES, AND TERMINAL BOARDS AS SHOWN ON THE DRAWINGS UNLESS OTHERWISE NOTED ON PLANS. TELEPHONE SWITCHING APPARATUS, CONDUCTORS, INSTRUMENTS, MISCELLANEOUS EQUIPMENT AND APPURTENANCES ARE NOT PART OF THIS CONTRACT AND WILL BE PROVIDED AND INSTALLED BY T.S.P.. 2. OUTLET BOXES TO BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. 3. CONDUIT RUNS FROM TELEPHONE BOARD OR MANAGER'S OFFICE FOR TELEPHONE AND DATA LINES TO CASHWRAPS ARE TO BE CONTINUOUS WITH NO JUNCTION BOXES EXCEPT AS NOTED OTHERWISE ON DRAWINGS. 4. ALL PULL WIRES ARE TO BE LABELED FOR PURPOSE DESIGNATED. 5. NO OTHER CIRCUITS ARE TO BE RUN IN SAME CONDUIT FEEDING ISOLATED GROUND RECEPTACLES. P. TESTS AND ADJUSTMENTS 1_ ALL CONNECTIONS AT PANELS AND SWITCHES ARE TO BE MADE, ALL SPLICES COMPLETE, ALL FUSES IN PLACE, AND ALL CIRCUITS CONTINUOUS FROM POINT OF SERVICE CONNECTION TO ITS FINAL DESTINATION, AND ALL COVERS AND PLATES INSTALLED PRIOR TO THE TIME OF FINAL INSPECTION BY T.S.P.'S CONSTRUCTION MANAGER. 2. UPON COMPLETION OF THE WORK, ALL PARTS OF THE ELECTRICAL INSTALLATION SHALL BE TESTED AND PROVED FREE OF UNWANTED GROUNDS AND OTHER DEFECTS. 3. ALL OVERLOAD DEVICES, INCLUDING EQUIPMENT FURNISHED UNDER OTHER CONTRACTS, SHALL BE SET AND ADJUSTED TO SUIT THE LOAD CONDITIONS. 4. TEST AND MAKE CORRECTIONS /ADJUSTMENTS FOR PHASE BALANCING_ 5. THIS CONTRACTOR IS TO BALANCE THE VOLTAGE LEAVING THE STEP - DOWN TRANSFORMER TO PROVIDE A SECONDARY VOLTAGE OF 120 MINIMUM TO 125 VOLTS MAXIMUM BY ADJUSTING THE TRANSFORMER TAPS ONCE ALL THE FINAL CONNECTIONS HAVE BEEN MADE TO THE LOW VOLTAGE PANELBOARD. PROVIDE FINAL BALANCE REPORT TO T.S.P. CONSTRUCTION MANAGER AT TIME OF PUNCH-OUT. O. CLEANING 1. AT THE END OF THE PROJECT, THIS CONTRACTOR SHALL CLEAN ALL EQUIPMENT, INCLUDING LIGHT FIXTURES, TO THE SATI'S'FACTION OF T.S.P.. ALL DUST, DIRT, DEBRIS, AND FOREIGN MATTER SHALL BE REMOVED FROM ALL EQUIPMENT. END OF SECTION 16050 CODE RMENNED FOR NF APR - 2 no COY Tukwila ILDIN • DM :I N RECEIVED MAR 07 2008 PERMIT CENTER 0 01 r O r co z 0 W co d V 1- 0 f/ I I ' + 9 . / _co ES- e S iLu z N 1 4, a ' c , ' . 5 c S f Et ON A\ 'c , _ . E XPIRES 6/10/ d r+33:G limn7i7 inr.:."i:9 . :3:intz7:.'li.znii7S[unniSt; 0 z 4, fJ • n 0 CO THE IET4GINEER ASSUN/ES NO RESPONSIBILITY OR LIABILITY FOR THE USE OF THESE PLANS FOR ANY PROJECT OTHER THAN SPECZfICALI.Y AUTHORIZED BY THEM AND STIED AND SEALED FOR SUCH SPECIFIC LOCATION IN THE STATE SHOWN ON THE SEAL. THIS BUILDING USE I5 ONLY APPLICABLE IN AREAS MEETING THE STATED DESYGN CRITERIA. HBK # 07164 DRAWING NUMBER: 0 z 0.3 tri 1 W z