Loading...
HomeMy WebLinkAboutPermit EL07-801 - WESTFIELD SOUTHCENTER MALL - EXPANSION PHASE IWESTFIELD EXPANSION PHASE I 2800 SOUTHCENTER MALL ELO7-80 1 City..af Tukwila Parcel No.: 6364200010 Address: 2800 SOUTHCENTER MALL TUKW Suite No: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Tenant: Name: WESTFIELD MALL EXPANSION - PHASE I Address: 2800 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WEA SOUTHCENTER LLC Phone: Address: 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: THERESA LARGUSA Phone: 206 - 915 -2378 Address: 6027 44 AVE SW , SEATTLE WA Contractor: Name: PIONEER GROUP INC Phone: 360 -790 -6805 Address: P 0 BOX 1362 , GOLD BAR WA Contractor License No: PIONEGI932M6 Expiration Date: 07/26/2009 DESCRIPTION OF WORK: TELECOMMUNICATIONS PHASE I: INSTALL FIBER AND COPPER CABLE WITH CONNECTORS FOR THE OPERATION OF IN- BUILDING ANTENNA SYSTEM. Value of Electrical: $99,000.00 Fees Collected: Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Signature: doc: EL -4/07 ELECTRICAL PERMIT Permit Number: EL07 -801 Issue Date: 01/18/2008 Permit Expires On: 07/16/2008 $1,862.50 Date: I hereby certify that I have read and *am4ted this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied tt1IJ,, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or t}ye performance of work. I am authorized to sign and obtain this electrical permit. Date: )---/ Print Name: 71 e're-g This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. EL07 -801 Printed: 01 -18 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: 1: ** *ELECTRICAL * ** Signature: Print Name: doc: Cond -Elec City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2800 SOUTHCENTER MALL TUKW WESTFIELD MALL EXPANSION - PHASE I PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: ELO7 -801 ISSUED 12/24/2007 01/18/2008 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: EL07 -801 Printed: 01 -18 -2008 Name: 1 Lav Gos E -Mail Address. Will service be altered? Type of Use: Type of work: ❑ New ❑ Low Voltage Property Served by: Puget Sound Energy ❑ Seattle City Light CITY OF TUKWILA Community Development Department Permit Center 6300 SouthcenterBlvd., Suite 100 Tukwila, WA 98188 httrx//www.ci.tukwila.wa. us u E -Mail Address 1arq Contractor Registration Number: KAApplieatierrsFor-- 47Feso On Sad.4 -2007 - Elen_•iel Permit Apptimen dec Ah Electrical Permit No. LO7- Po I Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION 63(0 - 00 to King Co Assessor's Tax No.: / "" �� Site Address: 6j 3 3 1��.e l 074 l Suite Number. Floor:Lewe tr L,ew ." Tenant Name: A ne r k_a.h— TDWt f e_c l- onaii.rrlti Propert Owners Name: WeA{'1 te, kt.,: BQ et.� - LL GtX'( YL Mailing Address: 1160 81; F%' r L ede,5 (t, 4 ga925 State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Mailing Address: 10021 efif $1■0 / v i9 ❑ Yes w Addition Generator ❑ Service Change ❑ Fire Alarm New Tenant: ❑ Yes [ No Day Telephone: 2cfp- 6 115-2378 Sea4#t WA( R g 136 CFa r� Zia co y ih x Number. 360- 743- - l 3 20 ELECTRICAL CONTRACTOR INFORMATION Company Name:P Ofee r Am. Pierced C / o rp . o Mailing Address: 430 B')0( 13i0 2 &jp I.GL &Lk- W,- 7 /� 11251 Contact Person: I e e1/4.- City State T :n D a y Telephone: 204 – 415 - .237g Fax Number. 3ipn- 713-732o Expiration Date: Valuation of Project (contractor's bid price): S 1 q, 000 . c o Scope of Work (please provide detailed information): TelecorntriLat kal c 8 Phase_ h&se_ ets ittiA e -Citer akt ecfre.r cable- w►tgt.) e e c4 Adding more than 50 amps? ❑ Yes [ ' No ❑ Tenant Improvement ❑ Remodel lir Telecommunication ❑ Temporary Service Page ! et 2 RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) BUILDING OWNER OR ELECTRICAL CONTRACTOR: RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings S140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, fumace thermostat) $55.00 ea Signature. �j" PrimName: 1 here -3 _ L. Lar-8,4..za _ Mailing Address: (00Z7 £E4 Ave.. ■A MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured /mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of constniction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: /2/z 4 1/Z907 Day Telephone: 2O R/5 '- 25 78 Ste. IA/A c$t 3fe Cry State Zip 1 t) 7 i Date Application Expires: /' Staff Initials: UV 1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL07 -801 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 12/24/2007 Applicant: WESTFIELD MALL EXPANSION - PHASE I Issue Date: Receipt No.: R07 -02849 Initials: WER Payment Date: 12/24/2007 09:35 AM User ID: 1655 Balance: $0.00 Payee: PIONEER GROUP INC TRANSACTION LIST: Type Method Description Amount Payment Check 14940 1,862.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 ELECTRICAL PLAN - NONRES 000.345.832.00.0 1,490.00 372.50 Total: $1,862.50 Payment Amount: $1,862.50 6391 12/24 9710 TOTAL 1862.50 doc: Receiot -06 Printed: 12 -24 -2007 Project: w�s%ji`� ��/° / 1 Type of Inspection: r` /CO " Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION K 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: f /A/4z_ Fay Iln 1/ /JarIi a/v /(/ ( , ,% El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: COMMENTS: — F /AE n ^if A — )1?201/1aF PLYGi)()7 f(j2 14)6N4 621 &72/ 0A) � ` �.� of FA, se 4 / 9 ,gm c4 ,t * f'i S1 /S/'?/ c / Requester: Phone No 9/r f ,23 Project: Type of Inspection: "e<eir : SG /17 /94 L Date Called: Special Instructions: PNASL / Date Wanted: CO / 2-r p.m. Requester: Phone No 9/r f ,23 INSPECTION NO. INSPECTION RECORD Retain a copy with permit kt42.40/ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. Eorrections required prior to approval. J Inspect o. / 6 L jl•/7 /91/4/-1 IDate: / /a 2,��{f ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project:. F. . w r t�Y p Type of Inspection: vG Address: Zoo© qu• Date Called: 00t, 4 IN) ^� Special Instructions: Date Wanted: t0/ a .m. Irr Requester: (7 KO DI /J. AtR4Cif Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6 ‘4, , 00t, 4 IN) • 6,01 (7 KO DI /J. AtR4Cif INSPECTION NO. 'Inspector: INSPECTION RECORD Retain a copy with permit 6- S'61 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ) 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 1 444 'Date. 06 I/ /OP El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: `Date: AL OPT022 INSTALLATION INSTRUCTIONS: 1. CONNECT THE POWER CORD TO THE NC OUTLET. 2. CONNECT THE TEMPERATURE SENSOR TO THE CARD IN SLOT 9 & SECURE SENSOR TO ONE OF THE CABINET RAILS. 3. CONNECT THE CABLE BETWEEN THE CARD IN SLOT 0 AND THE UPS. 4. CONNECT THE CABLES FROM THE OPTO CARD IN SLOT #1 TO THE SUMMARY ALARM RELAY CONNECTOR ON THE BACK OF THE ANDREW SUPERVISION UNIT. 5. CONNECT A NETWORK CABLE FROM THE LAN CONNECTION PORT ON THE ANDREW SUPERVISION UNIT TO OPEN PORT ON THE NETGEAR SWITCH. 6. CALL THE NOC AT 1- 888 - 773 -4122 TO HAVE THE SITE ACTIVATED AND TESTED. MODEM SHELF MODEM FRONT VIEW , STANDARD NETWORK CABLE (PROVIDED BY ATC) ( / NETGEAR 5 PORT SWITCH V _ - ROJECT INFORMATION O 4 7 O O Q O O O 0 Q SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE,WA 98188 CISCO 1721 SITE ID: 344199 // / CURRENT ISSUE DATE 11 /1 9/2007 1. OPT022 INSTALLATION INSTRUCTIONS (PROVIDED BYATC) • J� 5 ACTIVE SUBRACK #1 P \� 5 1,6 5A g5 52 R El ck 5 2 ISSUED FOR CONSTRUCTION CONNECTIVITY MENU CONFIGURATION MENU OPTO IP 10.88.10.162 COM PORT COM 2 =DATE — ISSUED FO Y _REV.: 0 06/19/2007 PRELIMINARY ACS ROUTER IP 172.30.3.202 BAUD RATE 9600 1 0621 /2007 OWNER APPROVAL ACS TSUN IP 10.88.10.163 STANDARD NETWORK CABLE FROM NETGEAR SWITCH TO FRONT OF OPT022 (PROVIDED BY ATC) (PROVIDED BY ATC) 2 09/10/2007 PRELIMINARY ACS BRITECELL CONFIGURATION INSTRUCTIONS: 3 09/26 /2007 OWNER APPROVAL ACS r ACTIVE SUBRACK #2 (PROVIDED P\O FL i 232 4 11/05/2007 CONSTRUCTION ACS 5 11/19/2007 CONSTRUCTION ACS , � mr: 1. SET DIP SWITCHES ON EACH ACTIVE SUBRACK ACCORDING TO ITS ADDRESS (SEE TABLE BELOW). CONNECT ALL MONITORING & SUPERVISION CABLES AS SHOWN. 2. ENSURE ALL ANDREW EQUIPMENT (INCLUDING REMOTE UNITS) IS INSTALLED, CONNECTED, AND POWERED UP. 3. CONFIGURE LAPTOP FOR IP ADDRESS SHOWN IN CHART BELOW AND CONNECT ANDREW CROSSOVER CABLE BETWEEN TSUN AND 4. OPEN INTERNET EXPORER AND BROWSE TO TSUN IP ADDRESS. LOG INTO TSUN. LOG IN AND PASSWORD ARE BOTH "DASIC ". 5. ACCESS TSUN AND PERFORM "CLEAR ALL AND ADD" DISCOVERY DURING INITIAL INSTALLATION. 6. VERIFY THAT ALL SUBRACKS, ACTIVE MODULES, AND REMOTE UNITS APPEAR IN THE INVENTORY. 7. DISABLE ALL UNUSED SUBRACK SLOTS. 8. MASK ALARMS ON ALL UNUSED TFLN PORTS. 9. ENSURE NO WARNINGS OR ALARMS OF ANY KIND REMAIN. BY ATC) STANDARD FUTURE SUBRACKS RS - 232 I,_ CO • ,•' , ~]• � 70 , ; � LA PTOP. ' -� — F ` ANS PREPARED BY l JAN 1 1 ZGOO CABLE (PROVIDED i BY ATC) TO FRONT OF OPT022 SUPERVISION UNIT UPS ANDREW SUPERVISION UNIT C & NC - TSUN G0�2P ON 0 F STANDARD NETWORK CABLE FROM NETGEAR SWITCH TO FRONT y�. C, O f T Jllll U �I a • II . � ^ __ 1 � . , / a = / - - - j-1 +vV American Tower Corporation 0 Proprietary and C employees 2007. Intended Tor limited use by employees and agents only while performing work for American Tower. Not to be distributed without the express written consent of American Tower Corporation ACTIVE ACTIVE SUBRACK DIP SWITCH SETTINGS OF TSUN BY ATC) 1 2 3 4 5 6 7 8 (PROVIDED 0 1 ON OFF OFF OFF OFF OFF OFF OFF o 1 2 6 7 8 9 NOTE: 1. DAISY CHAIN ANY ADDITIONAL ACTIVE SUBRACKS TOGETHER USING ADDITIONAL STANDARD (NON- CROSSOVER) NETWORK CABLES. 2. ALL ALARM / MONITORING CABLES ARE PROVIDED BY ATC 2 OFF ON OFF OFF OFF OFF OFF OFF 12 2 • 19 : OPTO 22 3 ON ON OFF OFF OFF OFF OFF OFF BY CHK — 4 OFF OFF ON OFF OFF OFF OFF OFF + DRAWN _APV A. SLAA I J MD I RF 2. BRITECELL CONFIGURATION NOTES IL _JI _LICENSURE DEC Z'4 2007 PERMIT f` !J CNTEI PERMIT G® L/T1117;711 OPT022 CONFIGURATION BLUE NETWORK CABLE TELEPHON SLOT FROM TO BLUE NETWORK CABLE CONNECTRED FROM EXTERNAL MODEM CONNECTRED TO BACK OF THE CISCO 1841 ROUTER ROUTER HERE JACK ,, TEMPERATURE SENSOR SLOT 0 UPS CARD BACK OF UPS SLOT 1 TERMINALS 1 TERMINALS 2 TERMINALS 3 & 4 TERMINALS 5 & 6 TERMINALS 7 & 8 TSUN ALARM "C" TSUN N ACTIVE SUBRACK K #1 #t AU AUX l0 0 PINS 5 & 6 ACTIVE SUBRACK #2 AUX 10 PINS 5 & 6 ACTIVE SUBRACK #3 AUX 10 PINS 5 &6 TITLE =SHEET _ ale ..n _ c,.ru �u • MODEM SHELF & TSUN ACTIVE SUBRACK CABLE DETAILS � �rM .,..,tuna. . a's s _ I + . � ? ° • r. , c • .�--� L • • n... •,` cI500 t 41 - ..��'�` ' ; - ° 1 ,. BACK OF POWERWARE 9125 UPS BACK OF SLOT 2 TERMINALS 1 & 2 TERMINALS 3 & 4 TERMINALS 5 & 6 TERMINALS 7 & 8 ACTIVE SUBRACK #4 AUX 10 PINS 5 &6 ACTIVE SUBRACK #5 AUX 10 PINS 5 & 6 ACTIVE SUBRACK #6 AUX 10 PINS 5 & 6 ACTIVE SUBRACK #7 AUX* PINS 5 & 6 inn luuTllnlmi, AMR ° A ' 1 , s _ w e ® - I • . t-, ���... -•_ NUMBER REVISION =SHEET CONNECT NETGEAR SWITCH TO THE 10/100 ETHERNET PORT ED 12 5 BATTERY SLOT 9 TEMPERATURE SENSOR 3. CISCO ROUTER REAR VIEW 4. OPT022 & MODEM SHELF WIRING DIAGRAM 0 06/19/2007 PRELIMINARY ACS 1 06/21/2007 OWNER APPROVAL ACS 2 09/10/2007 PRELIMINARY ACS 3 09/26/2007 OWNER APPROVAL ACS 4 11/05/2007 CONSTRUCTION ACS 5 11/19/2007 CONSTRUCTION ACS C •,, • .�, PLANS ' -tYll�iiL MI . iaa C JAN 1 1 2008 L EXAMPLE SHOWS 1 PCS / SMR SYSTEM A AND 1 PCS / CELL SYSTEM B (FUTURE) WITH FULL ANTENNA LAYOUT. SEE PREVIOUS PAGE FOR INSIDE BOX DETAIL 12" x 18" NEMA BOX EXAMPLE SHOWS 1 PCS / CELL SYSTEM A AND 1 PCS / SMR SYSTEM B (FUTURE) WITH FULL ANTENNA LAYOUT. SEE PREVIOUS PAGE FOR INSIDE BOX DETAIL 12" x 18" NEMA BOX REMOTE UNIT NODE 1-4 n n nnn n 11 n mLE �- 2 SMF for Spare REMOTE UNIT NODE 1 -2 r 2 SMF for PCS /SMR SYSTEM A 2 SMF for PCS / CELL SYSTEM A U U Un U U U U Un u_ 2 SMF for Spare =2110 of PIT nl= Typically 75 Feet r RU and Antenna 2 SMF for PCS / CELL SYSTEM B (FUTURE REMOTE UNIT) 2 SMF for PCS / SMR SYSTEM B (FUTURE REMOTE UNIT) OMNI ANTENNA NODE 1-4-1 PCS /SMR SYSTEM A 24 Feet Min Separation PCS /CELL SYSTEM B OMNI ANTENNA NODE 1-4-2 PCS / SMR SYSTEM A 24 Feet Min Separation PCS / CELL SYSTEM B DIRECTIONAL ANTENNA NODE 1-2-1 PCS /CELL SYSTEM A T PCS /SMR SYSTEM B OMNI ANTENNA NODE 1 -2 -2 PCS / CELL SYSTEM A 24 Feet Min Separation PCS /SMR SYSTEM B 5 Feet Min Separation Between SMR and CELL I EXAMPLE SHOWS THE WIRING TO 1 REMOTE UNIT PCS / CELL, SYSTEM A TRI -BAND OMNI �r- BAND OMNI ANTENNA ANTENNA A FIBER TO EQUIPMENT 1 l / / Y2" COAXIAL — f \ 1 ` Y2 " COAXIAL CABLE N -MALE 1 1 CABLE N -MALE TO N -MALE UL 1 DL I TO N -MALE �I -, I n r r il 7 ,- RG -142 OR EQUIVALENT N- FEMALE TO N -MALE REMOTE UNIT EXAMPLE SHOWS THE WIRING TO 1 REMOTE UNIT PCS / CELL, SYSTEM A 1 TRI-BAND OMNI ANTENNA 17 — RG -142 OR EQUIVALENT N- FEMALE TO N -MALE i Y2" COAXIAL j ■ 1 Y" COAXIAL CABLE N -MALE I I CABLE N -MALE TO N -MALE UL I DL I TO N -MALE E 3 riti, : 00 FIBER TO EQUIPMENT iv ■ REMOTE UNIT O O DIRECTIONAL J ANTENNA (N- FEMALE) 7 ,.. , - RG -142 OR EQUIVALENT N- FEMALE TO N -MALE 806 -2500 MHz 0 A ROJECT INFORMATION SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE,WA 98188 SITE ID: 344199 CURRENT ISSUE DATE 11/19/2007 ISSUED FOR CONSTRUCTION REV.:= DATE:— ISSUED FOR �livc D Proprietary and Confidential for limited use by employees and agents only while performing work for American Tower. Not to be distributed without the express written consent of American Tower Corporation. =DRAWN BY: CHK APV 1 A. SLAA I JMD I RF (CENSURE RECEIVED DEC 2'4 2007 NIT nr- nlTr _SHEET TITLE ANTENNA & REMOTE UNIT WIRING EXAMPLES =SHEET NUMBER REVISION— D11 5 0 06/19/2007 PRELIMINARY ACS 1 06/21/2007 OWNER APPROVAL ACS 2 09/10/2007 PRELIMINARY ACS 3 09/26/2007 OWNER APPROVAL ACS 4 11/05/2007 CONSTRUCTION ACS 5 11/19/2007 CONSTRUCTION ACS • It. '._ OMPI TA n,, POLE TO BE MOUNTED TO STRUCTURAL MEMBER OR STUD. METHOD OF FASTENING TO BE DETERMINED IN FIELD 2" DIA. POLE NOTE: DIRECTIONAL ANTENNAS TO BE MOUNTED WITH APPROPRIATE SIDETILT AND /OR DOWNTILT SO THEY POINT DIRECTLY AT THE ENTRANCE TO THE ANCHOR STORE OR OTHER INTENDED COVERAGE AREA OMNI DIRECTIONAL ANTENNA 6. WALL PENETRATION DETAIL WALL STUD %" GYP BD. FINISHED INTERIOR VERTICAL WALL SURFACE DIRECTIONAL ANTENNA DETAIL APPLIES TO ANTENNA NODES ON PAGE D1, D2, & D3 �— CEILING 1. ADJUSTABLE POLE MOUNT EXAMPLE WALL STUD 5/8" GYP BD . FINISHED INTERIOR WALL SURFACE DETAIL APPLIES TO ANTENNA NODES ON PAGE D1 3. WALL /CEILING MOUNT EXAMPLE - OMNI SPACE BETWEEN THE PENETRATING ITEM, AND BETWEEN THE SLEEVE AND ASSEMBLY PENETRATED MUST BE PROTECTED BY AN APPROVED FIRE -STOP MATERIAL OR SYSTEM AGAINST THE PASSAGE OF FLAME AND HOT GASES. MANUFACTURE: 3M (OR EQUIVALENT) FIRE BARRIER SEALANT: CP 25WB+ ASTM E 814 (UL 1479) ASTM E 84 (UL 723) \\-- MUST B SLEEVES UST E SECURELY FASTENED TO THE ASSEMBLY PENETRATED ANTENNA MOUNTING NOTES: 1. ANTENNAS TO BE MOUNTED IN MALL INTERIOR IN EXACT LOCATIONS INDICATED ON FLOOR PLANS UNLESS SPECIFICALLY APPROVED OTHERWISE BY THE ATC PROJECT MANAGER. 2. TWO PARALLEL ANTENNA AND 1/2" COAX SYSTEMS TO BE INSTALLED EACH ANTENNA SHOWN ON FLOOR PLAN INDICATES A GROUP OF ANTENNAS AT THAT LOCATION, EACH ANTENNA WITH ITS OWN COAX BACK TO THE REMOTE UNIT. REMOTE UNITS FOR SYSTEMS SHOWN GRAYED OUT ON MAIN HUB & BTS INTERFACE SYSTEM DRAWING WILL NOT BE INSTALLED DURING THIS CONSTRUCTION. DUST CAPS TO BE PLACED ON ANY COAX CONNECTORS WHICH ARE NOT CONNECTED TO REMOTE UNIT PORTS. 3. BOTH ANTENNAS AT A LOCATION TO BE MOUNTED IN THE SAME PLANE AND WITH SIMILAR VIEWS OF INTENDED COVERAGE AREA. OMNI ANTENNAS TO BE SPACED 24 FEET APART. SMR & CELL BAND DIRECTIONAL ANTENNAS TO BE SPACED A MINIMUM OF 5 FEET APART (SEE DETAIL ON NEXT PAGE). 4. ANTENNAS MUST NOT BE MOUNTED BEHIND OR WITHIN 6 INCHES OF METALLIC OBJECTS, OR NEAR LARGE OR DENSE ARCHITECTURAL FEATURES SUCH AS COLUMNS, OVERHANGS, ETC WHICH MAY OBSTRUCT THEIR SIGNAL. 5. ALL ANTENNAS TO BE RIGIDLY MOUNTED TO AN IMMOBILE OBJECT SO THAT THEIR LOCATION AND ORIENTATION CAN'T BE CHANGED WITHOUT DISASSEMBLY OF THE MOUNTING BRACKET. 6. UTILIZE PROVIDED TORQUE WRENCH FOR ALL SMA CONNECTORS TO ENSURE PROPER TORQUING OF SMA FITTING ONTO RAU & ANTENNA. TORQUE IS 8 LB- INCHES. 7. DIRECTIONAL ANTENNAS TO BE MOUNTED BEHIND FINISHED GYPSUM BOARD SURFACE HIDDEN FROM PUBLIC VIEW UNLESS OTHERWISE NOTED OR APPROVED BY ATC PROJECT MANAGER. THESE ANTENNAS REQUIRE ACCESS FOR MAINTENANCE. ACCESS CAN BE EITHER THROUGH EXISTING ACCESS PANELS OR NEW ACCESS PANELS DETAILED WITHIN THIS DRAWING PACKAGE. 8. ALL DIRECTIONAL ANTENNAS SERVING ANCHOR STORES TO BE POINTED DIRECTLY AT THE CENTER OF THE ENTRANCE OF THE STORE BOTH HORIZONTALLY AND VERTICALLY. 5. NEMA BOX WITH 1 POWER SUPPLY AND 1 COYOTE SPLICE TRAY 82" POWER SUPPLY +5 VDC RF AUXILLIARY CHANNEL INPUT (SMA -F) RF TRx PORT (N -F) --} TKA MOUNTING KIT (SPLICE HOLDER) DL OPTICAL PORT (SC -APC) UL OPTICAL PORT (SC -APC) RF TRx PORT (N -F) I L 3?" 8 1 at V I� U U U U 110 U 0 8 T r 8 91" RF AUXILIARY CHANNEL INPUT (SMA -F) TKA NOTE: 1 Oq" TKA INSTALL KIT CONTAINS A FIBRE OPTICS SPLICE HOLDER AND A COMPACT CASE FOR EASY INSTALLATION OF THE TFA ON WALLS OR POLES. REMOTE UNITS MOUNTED IN PLENUM SPACES TO HAVE REMOTE UNIT POWER SUPPLY ENCLOSED IN ELECTRICAL BOX. 2. REMOTE UNIT DETAILS REMOTE UNIT POWER SUPPLY, SYSTEM A NOT PLENUM RATED, INSTALL IN NEMA BOX 12" x 18" NEMA BOX COMPOSITE CABLE 2 SMF FOR PCS / CELL, SYSTEM A 2 SMF FOR PCS / SMR, SYSTEM B 2 SMF FOR SPARE 3 PAIR #16 AWG COPPER WIRE REMOTE UNIT 7 REMOTE UNIT POWER SUPPLY SYSTEM B NOT INSTALLED (FUTURE) COYOTE TWELVE -COUNT SPLICE TRAY PN: ANIXTER 80806033 COIL FIBER AS NEEDED 2 SMF o 4. REMOTE UNIT & ELECTRICAL BOX WITH SPLICE TRAY FROM REMOTE UNIT OUTPUT Emi COUPLED M Illig DIRECTIONAL COUPLER IN OUT TO THIRD LOW 41 POWER ANTENNA TO FULL POWER ANTENNA 6dB DIRECTIONAL COUPLER 7. DIRECTIONAL COUPLER DETAIL A ROJECT INFORMATION SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE,WA 98188 SITE ID: 344199 CURRENT ISSUE DATE 11/19/2007 ISSUED FOR I CONSTRUCTION EV.= DATE: = ISSUED FOR. 8 PLANS JAN 1 1 2088 American o Proprietary and Confidential ® 2007, for limited use by employees and agents only while performing work for American Tower. Not to be distributed without the express written consent of American Tower Corporation. DRAWN BY: LICENSURE =SHEET TITLE = SHEET NUMBER. CHK _APV J 1 A. SLAA I JMD I RF , RECEflEI DEC 2 ° 4 Z007 PERMIT (BEN I • ANTENNA MOUNTING & REMOTE UNIT DETAILS REVISION_ D10 5 DIRECTIONAL ANTENNAS TO BE MOUNTED WITH APPROPRIATE SIDETILT AND /OR DOWNTILT SO THEY POINT DIRECTLY AT THE ENTRANCE TO THE ANCHOR STORE OR OTHER INTENDED COVERAGE AREA 8 16 Cellular Specialties, Inc Model Number CSI -AP / 806 / 2.5k / 7 -10 Frequency Range 806 -960 / 1710 -2500 Antenna Gain 7dBi (806- 960MHz) 10dBi (1710- 2500MHz) Polarization Vertical Ground Plane Built -In VSWR < 1.5 : 1 Impedance 50ohms Connector N Female Dimensions 8.19" x 7.0" x 1.73" Weight 1.321bs 1.3 Ibs (Mounting Hardware) 3. DIRECTIONAL ANTENNA DETAILS NOTE: 12" BACK PAINTED TO MATCH EXISTING FIXTURES. VERIFY WITH MANAGEMENT. DEPENDING ON EQUIPMENT PLACED ABOVE CEILING DICTATES THE SIZE OF ACCESS PANEL, MIN 12" MAX 24 ". 2. ACCESS PANEL DETAIL ANDREW Part Number Frequency Range Impedance Antenna Gain Azimuth Beamwidth VSWR Connector Dimentions Weight J / — SLEEVES MUST BE SECURELY FASTENED TO THE ASSEMBLY PENETRATED SPACE BETWEEN THE PENETRATING ITEM, AND BETWEEN THE SLEEVE AND ASSEMBLY PENETRATED MUST BE PROTECTED BY AN APPROVED FIRE -STOP MATERIAL OR SYSTEM AGAINST THE PASSAGE OF FLAME AND HOT GASES. MANUFACTURE: 3M (OR EQUIVALENT) FIRE BARRIER SEALANT: CP 25WB+ FIRE ASTM E 814 (UL 1479) ASTM E 84 (UL 723) 2 06" 3. OMNI ANTENNA DETAILS 3 1 PCS - CELL SMR800 /900 CELLMAX- 0 - 25 806- 960MHz 1710- 2500MHz 50 Ohms 3 dBi 360° Omnidirectional <1.6:1 N Female 3.3H x 6.50 0.7Ibs COMMUNICATIONS ROOM PARKING DECK FIRST LEVEL GROUND LEVEL 72 SINGLE MODE FIBER SECOND L EVEL MACY'S 4 FLOORS NORDSTROM 3 FLOORS SEARS 3 FLOORS SECTOR 1 SECTOR 1 2 -2 -2 2 -2 -1 2 -1 -2 2 -1 -1 1 -4 -2 1 -4 -1 1-3-2 1 -3 -1 1 -2 -2 1 -2 -1 1 -1 -2 L . 1 -1 -1 SECTOR 1 TRUNKING LEGEND v FAP OMNI ANTENNAS DIRECTIONAL ANTENNAS 2:1 POWER DIVIDER NEW ACCESS PANEL FIBER AGGREGATE POINT COMMUNICATIONS ROOM DUAL Y2" COAX RUN — — FIBER RUN - -- COMPOSITE FIBER RUN SECTOR 2 SECTOR 2 r FAP #2 SECTOR 2 72 SINGLE MODE FIBER CPENNY'S 3 FLOORS RENUMBERED AMC THEATERS 1 FLOOR FUTURE RETAIL 2 FLOORS PHASE 3 5 -2- 5-2-1 5 -1 -2 ADDED 5 -3 IN 5 -1 -1 FOOD COURT PHASE 2 4-4 -2 4-4 -1 4 -3 -2 4 -3 -1 4 -2 -1 4 -1 -2 4 -1 -1 PHASE 1 1. DESIGN TRUNKING DIAGRAM w ROJECT INFORMATION SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE,WA 98188 SITE ID: 344199 CURRENT ISSUE DATE C 11/19/2007 I SSUE CONSTRUCTION _REV.: = DATE: = ISSUED FOR: BY 2 3 4 06/19/2007 06/21/2007 09/10/2007 09/26/2007 11/05/2007 11/19/2007 PRELIMINARY OWNER APPROVAL PRELIMINARY OWNER APPROVAL CONSTRUCTION CONSTRUCTION tMq■Ip lob ACS ACS ACS ACS ACS ACS 1 Proprietary and Con de for limited use by employees and agen while performing work for American Tower. Not to be distributed without the express written consent of American Tower Corporation. DRAWN BY: CHK _APV I A. SLAA I JMD I RF LICENSURE RE-C I17, DEC 2'4 2007 PERMIT CENTEi =SHEET TITLE TRUNKING DIAGRAM ACCESS PANEL DETAILS — SHEET NUMBER. REVISION_ D9 5 O 3 -2 -2 r ue 3 -2 -1b 3 2 -0 3 -2 -la 0 3 -1 -2 I t 3-1 0 3 -1 -1 " 2 -4 -2 -4.1b II 24 Io 2 II i a 2-4 -1a III 9 2-3-2 r. I 2-3-1b 2 -3 1 III a 2 -3 -1a DIRECTIONAL ANTENNAS TO BE MOUNTED WITH APPROPRIATE SIDETILT AND /OR DOWNTILT SO THEY POINT DIRECTLY AT THE ENTRANCE TO THE ANCHOR STORE OR OTHER INTENDED COVERAGE AREA 8 16 Cellular Specialties, Inc Model Number CSI -AP / 806 / 2.5k / 7 -10 Frequency Range 806 -960 / 1710 -2500 Antenna Gain 7dBi (806- 960MHz) 10dBi (1710- 2500MHz) Polarization Vertical Ground Plane Built -In VSWR < 1.5 : 1 Impedance 50ohms Connector N Female Dimensions 8.19" x 7.0" x 1.73" Weight 1.321bs 1.3 Ibs (Mounting Hardware) 3. DIRECTIONAL ANTENNA DETAILS NOTE: 12" BACK PAINTED TO MATCH EXISTING FIXTURES. VERIFY WITH MANAGEMENT. DEPENDING ON EQUIPMENT PLACED ABOVE CEILING DICTATES THE SIZE OF ACCESS PANEL, MIN 12" MAX 24 ". 2. ACCESS PANEL DETAIL ANDREW Part Number Frequency Range Impedance Antenna Gain Azimuth Beamwidth VSWR Connector Dimentions Weight J / — SLEEVES MUST BE SECURELY FASTENED TO THE ASSEMBLY PENETRATED SPACE BETWEEN THE PENETRATING ITEM, AND BETWEEN THE SLEEVE AND ASSEMBLY PENETRATED MUST BE PROTECTED BY AN APPROVED FIRE -STOP MATERIAL OR SYSTEM AGAINST THE PASSAGE OF FLAME AND HOT GASES. MANUFACTURE: 3M (OR EQUIVALENT) FIRE BARRIER SEALANT: CP 25WB+ FIRE ASTM E 814 (UL 1479) ASTM E 84 (UL 723) 2 06" 3. OMNI ANTENNA DETAILS 3 1 PCS - CELL SMR800 /900 CELLMAX- 0 - 25 806- 960MHz 1710- 2500MHz 50 Ohms 3 dBi 360° Omnidirectional <1.6:1 N Female 3.3H x 6.50 0.7Ibs COMMUNICATIONS ROOM PARKING DECK FIRST LEVEL GROUND LEVEL 72 SINGLE MODE FIBER SECOND L EVEL MACY'S 4 FLOORS NORDSTROM 3 FLOORS SEARS 3 FLOORS SECTOR 1 SECTOR 1 2 -2 -2 2 -2 -1 2 -1 -2 2 -1 -1 1 -4 -2 1 -4 -1 1-3-2 1 -3 -1 1 -2 -2 1 -2 -1 1 -1 -2 L . 1 -1 -1 SECTOR 1 TRUNKING LEGEND v FAP OMNI ANTENNAS DIRECTIONAL ANTENNAS 2:1 POWER DIVIDER NEW ACCESS PANEL FIBER AGGREGATE POINT COMMUNICATIONS ROOM DUAL Y2" COAX RUN — — FIBER RUN - -- COMPOSITE FIBER RUN SECTOR 2 SECTOR 2 r FAP #2 SECTOR 2 72 SINGLE MODE FIBER CPENNY'S 3 FLOORS RENUMBERED AMC THEATERS 1 FLOOR FUTURE RETAIL 2 FLOORS PHASE 3 5 -2- 5-2-1 5 -1 -2 ADDED 5 -3 IN 5 -1 -1 FOOD COURT PHASE 2 4-4 -2 4-4 -1 4 -3 -2 4 -3 -1 4 -2 -1 4 -1 -2 4 -1 -1 PHASE 1 1. DESIGN TRUNKING DIAGRAM w ROJECT INFORMATION SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE,WA 98188 SITE ID: 344199 CURRENT ISSUE DATE C 11/19/2007 I SSUE CONSTRUCTION _REV.: = DATE: = ISSUED FOR: BY 2 3 4 06/19/2007 06/21/2007 09/10/2007 09/26/2007 11/05/2007 11/19/2007 PRELIMINARY OWNER APPROVAL PRELIMINARY OWNER APPROVAL CONSTRUCTION CONSTRUCTION tMq■Ip lob ACS ACS ACS ACS ACS ACS 1 Proprietary and Con de for limited use by employees and agen while performing work for American Tower. Not to be distributed without the express written consent of American Tower Corporation. DRAWN BY: CHK _APV I A. SLAA I JMD I RF LICENSURE RE-C I17, DEC 2'4 2007 PERMIT CENTEi =SHEET TITLE TRUNKING DIAGRAM ACCESS PANEL DETAILS — SHEET NUMBER. REVISION_ D9 5 4 LEGEN �j� I. I. �� j�/ jj�.. I Ii I: BAR JOIST 3 1/4" AMERICAN TOVVIIFt RO�E� INFORMATION 0 U ATTACHED TO CONCRETE CEILING OR ROOF IRON. ( MIN. 4' LONG) 2 THREADED ROD (TYP 5/8 ") 3 UNISTRUT FOR TOP OF CABINET (- 26" LONG) 4 UNISTRUT FOR BOTTOM OF CABINET ( -26" LONG) 5 TYP 5/8" NUTS & WASHERS FOR THREADED ROD O 6 NO E 8 AND NOTE #g WWIST -LOCK) 120 VAC, 3 WIRE- SEE 7 REAR DOOR 20" I I DOOR FIBER SPLICE TRAY 3 RU FRONT RACK RAILS BRIGHTCELL REMOTE POWER SUPPLY TRS/TRSN 3RU — BRIGHTCELL REMOTE POWER SUPPLY TRS/TRSN -3RU (FUTURE) MOUNTING BRACKET FOR UPS -2RU OC / SOUTHCENTER 0 i 19 RACK 633 SOUTHCENTER MALL SEATTLE,WA 98188 0 UNITS © iI I iI THREADED RODS II • SUPPORTING EHUB SITE ID: 344199 CURRENT ISSUE DATE !". 1 I I` © © O �fame � / ���� / ^�((� L � v � -�� ^ t /rA7 �' /J /' 4 ` \Y / � V /� A{ /. J \ / EHUB CABINET 36" CABINETS TO BE MOUNTED SECURELY TO BAR JOIST I 11/19/2007 I REAR RACK RAILS ISSUED FOR I CONSTRUCTION I ISSUED FOR: _REV.:CDATE:= 0 06/19/2007 PRELIMINARY r ACS 1 06/21/2007 OWNERAPPROVAL ACS 2 09/10/2007 PRELIMINARY ACS 3 4 09/26/1007 11/05/2007 OWNER APPROVAL CONSTRUCTION ACS ACS — — — — • O J R 5 11/19/2007 CONSTRUCTION ACS — � I_I 7'-6" 1 A.F.F. t — UNISTRUT (TYP) IEWED FOR C� � E COMPLIANCE SIDE VIEW NFPA 70 - NEC JAN 1 1 2008 r ' RU = RACK UNIT 1 ISOMETRIC VIEW 2 BAR JOIST MOUNTING DIAGRAM `PLANS PREPARED BY' CONSTRUCTION NOTES --- 0 o 0 o o o o 0 0 0 0 ° 0 o 0 0 REAR RACK RAILS 1 2. 3. BRACKETS CABINET ' / f �l ' ,/ � MOUNT FRONT RACK RAILS IN CABINET ATTACH REAR RACK RAILS TO UPS ATTACH COMPLETED ASSEMBLY, WILL ATTACH TO FRONT READY FOR EQUIPMENT ° 0 ° o ° ° MOUNTING FROM RACK TO BE FRONT RACK RAILS MOUNTING BRACKET FOR UPS 3.25" FROM FRONT DOOR GLASS BRACKETS STEP 2, TO CABINET. UPS RAILS. INSTALLED. 1. FIBER AGGREGATE POINT CABINET IS TO BE SUPPORTED BY THREADED ROD /UNISTRUT STRUCTURE. 2. SIDE OF CABINET IS TO BE SECURED TO WALL ONLY TO ENSURE THAT THERE IS NO MOVEMENT OF THE CABINET. THIS IS NOT FOR STRUCTURAL SUPPORT. 3 THE ATTACHMENT OF THE UNISTRUT TO THE CEILING BEAMS IS AT THE DISCRETION OF THE INSTALLER. INSTALLER TO USE APPROPRIATE ANCHORING GIVEN THE LOAD OF THE CABINET (- 225 LBS). 4. EXPOSED THREADED ROD AND UNISTRUT ENDS TO BE COVERED WITH PROTECTIVE CAPS. 5. BOTTOM OF CABINET TO BE MOUNTED AT 7' -6" AFF. 6. PULL BOX TO BE LOCATED WITHIN 6 CABLE FEET OF FIBER AGGREGATE POINT CABINET. 7. FIBER AGGREG POINT TO BE LOCATED AWAY FROM DOORS (APPROX. 6') SUCH THAT THE DOOR SWING WILL NOT CONTACT THE CABINET AND WORK CAN BE DONE SAFELY IN REAR OF CABINET, AS SHOWN IN FIGURE 6. 8. FIBER AGGREGATE POINT RECEPTACLE, CONNECT TO NEAREST UNSWITCHED 120V NORMAL POWER CIRCUIT (PROVIDE 277/120V TRANSFORMER IF POWER IS PROVIDED FROM UNSWITCHED 277V LIGHTING CIRCUIT) 9. CONTRACTOR TO PROVIDE CORD WITH 5 -20R OUTPUT CONNECTOR AND L5 -15P INPUT CONNECTOR. THIS CORD IS TO BE USED TO CONNECT THE UPS TO THE TWIST LOCK RECEPTACLE (SEE NOTE #9) TuDIV lfw 3 SIDE VIEW UPS BRACKET DIVI SION 3 "MIN — i ll / \ \ 1 \ / \ / ..- O / -� OTICE American Tower Corporation Proprietary and Confidential ® 2007. Intended for limited use by employees and agents only while performing work for American Tower. Not to be distributed without the express written consent of American Tower Corporation. DRAWN BY: CHK _APV / L — — A. SLAA I JMD I RF I b ICENSURE \ \ REAR \ \ REAR ��gg : RE ' DEC 2'4 2007 Eh PERMIT GENIE HINGE 3" MIN c DOOR JIDOOR ` _SHEET L TITLE FRONT \\ \� HINGE FRONT �' / FIBER AGGREGATE POINT MOUNTING DETAILS - REVISION_ , SHEET NUMBER OPTION A OPTION B (PREFERRED) HALLWAY D 8 5 4 BRACKETS MOUNTED IN RACK DETAIL 5 NOTES 6 EXAMPLE OF DISTANCE FROM DOOR v 4 CABLING NOTES 1. ALL CABLES TO BE NEATLY SECURED IN PLACE. AVOID SECURING CABLES OF DIFFERENT TYPES INTO THE SAME BUNDLE (I.E. SECURING ALARM CABLES TO POWER CABLE). 2. ALL CABLES (INCLUDING GROUND CABLES) MUST PENETRATE THE CABINET EITHER THROUGH THE CONDUIT AND JUNCTION BOXES SHOWN, OR THROUGH A PROPER WEATHERPROOF BULKHEAD FEED THROUGH DEVICE. DRIP LOOPS MUST BE PROVIDED ON ALL CABLES AS THEY ENTER JUNCTION BOXES AND CABINETS. 3. 110VAC POWER CABLES TURN FROM ALL HUBS AND OPT022 DOWN LEFT SIDE IN REAR OF CABINET IN VERTICAL PANDUIT RINGS, AND PLUGGED INTO POWER STRIP. SEE TABLE 4. UPS POWER CABLE PLUGGED INTO RECEPTACLE. 5. FRAME RELAY AND TELEPHONE WILL BE EXTENDED TO CABINET BY TELCO PROVIDER. 6. FIBER OPTIC CABLES ROUTED FROM CABLE TRAY DOWN ALONG LEFT AND RIGHT FRONT EDGES OF RACK RAILS IN VERTICAL PANDUIT RINGS. 7. TEMPERATURE SENSOR SECURED TO LEFT SIDE OF RAILS (NOT TO WALL OF CABINET). 8. CONTRACTOR TO PROVIDE AND INSTALL 25 PAIR CAT -5 CABLE FROM TELECOM CLOSET TO TELCO ENCLOSURE PROVIDED BY OTHERS IN EQUIPMENT ROOM. LEAVE SERVICE LOOP IN TELCOM CLOSET ADEQUATE TO REACH NETWORK INTERFACE UNITS IN THE ROOM. LEAVE 10' SERVICE LOOP IN THE TELCO ENCLOSURE IN EQUIPMENT ROOM. KEY SAFE NOTES -. ` t t 1. DASIC TO PROVIDE KEY SAFE. GE * t • SUPRA PUSH BUTTON PORTABLE k. LOCKBOX OR EQUIVALENT. r - - 2. PROGRAM KEY SAFE TO THE ATC +4 - } COMBINATION SPECIFIED BY THE ATC ( _..4 PROJECT MANAGER. #� 3. PLACE DAS CABINET KEY(S) INSIDE f AND SECURE TO CONDUIT, FENCE, OR ? } I OTHER DAS FIXTURE IN PLAIN VIEW OF 1 THE DAS CABINET. ti f KEY SAFE fs A �� •ROJECT INFORMATION SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE,WA 98188 SITE ID: 344199 CURRENT ISSUE DATE 11/19/2007 I NOTE: ISSUED FOR SET THE INTERNAL A/C UNIT'S THERMOSTAT TO 72° NC UNIT PLUGGED INTO POWER RECEPTACLE, NOT THE POWER CONSTRUCTION i ( 12" LADDER TRAY - - REV..-DATE_- ISSUED FOR: BY POWER RUNS - OUTSIDE CABINET - 0 06/19/2007 PRELIMINARY ACS STRIP OR UPS. _ - ATTENUATER SHELF From: To: Comment: 1 06/21/2007 OWNER APPROVAL ACS Duplex Receptacle Powerware 9125 UPS Main Power Feed for Cabinet 2 09/10/2007 PRELIMINARY ACS , � - 2RU Duplex Receptacle HVAC Main AC Feed for Cabinet 3 09/26/2007 OWNER APPROVAL ACS Powerware 9125 UPS REAR OUTLET Cabinet Power Strip All Main Hubs #1 -10 LADDER RACK 4 11/05/2007 CONSTRUCTION ACS _ SPLICE TRAY - 2RU k $ ELEV. = 8' / 5 11/19/2007 CONSTRUCTION ACS 1 PLUGS #1 O - II I • •• •• •• •• .... •• •• 8,1 .• •• •• •• .... •• •• •• •• • 1 11 , I ACTIVE SUBRACK 1 HOUSING SUBRACK INSTALLED 2 - - -4RU I PASSIVE SUBRACK h 3 _ _ 4 - - TOP OF CABINET 2" FIBER CONDUIT 5 ELEV. = 6' -3" -PLANS PREPARED BY' NEMA J -BOX 6 j 1 -4RU • I ACTIVE SUBRACK 7 1" TELCO CONDUIT FROM TELCO BOX CARRIER DEMARC w Z m U. 0 < 8 - - -4RU M I REMOTE ERVISION UNIT ; 9 - - 10 - - OTICE American Tower Corporation yee C empl yee s a and a nd a gents Intended Pro for pr limited use ietary and by empl:ye only while pe forming work for American Tower. Not to be distributed without the express written consent of American Tower Corporation. 11 - RU 12 ACTIVE SUB RACK INSTALLED I i � � � I 1 ' o I 022 ORU ; 13 ACTIVE SUB RACK INSTALLED VERTICAL LADDER - RACK • I 14 # •, 1 1'•' T TVA/ FOR r \ n ( DRAWN BV: CHK APV 15 REMOTE SUPERVISION UNIT INSTALLED = , N F7G ' -NEC L A. SLAA I JMD I RF 16 OPT022 HVAC TO 'I - POWER CORD (` JAN 11 2008 LICENSURE W _ DEC 224 2007 PERMIT CENTE 17 Modem Shelf TRANSFORMER 18 Modem Shelf TRANSFORMER 19 NEMA J -BOX BACK _ City Of Tukwila BUILDING DIVISION POWER IN 20 DUPLEX RECEPTACLE PROVIDED AND INSTALLED BY DASIC FINISHED FLOOR 1 UPS #1 Cabinet Power Strip #1 LEFT SIDE STRIP SHEET TITLE II ■ d � � O O O O POWERWARE 9125 OUTSIDE CABINET VIEWS OPT022, CABINET, POW DETAILS - - - - FLEX JUNCTION VIEW � , UPS 2 UARE JUNCTION BOX PROVIDED BY OTHERS * *RU = RACK UNIT 4 5 6 CONDUIT TO ELECTRICAL BOX AND 20A CIRCUIT OF CABINET UPS #3 UPS #4 SHEET NUMBER: REVISION; UPS #s - - S ELEV. = 0' ANCHOR TO CONCRETE SIDE VIEW OF CABINET D7 5 UPS #6 Cabinet Power Strip #2 RIGHT SIDE STRIP POWER SCHEDULE OF CABINET NOTES: A L# 2SVHd TFLN CARDS TO MAIN SPLICE TRAY IN CABINET MAIN SPLICE TO FIBER AGGREGATE POINT #2 SPLICE TRAY FIBER AGGREGATE POINT #2 SPLICE TRAY TO REMOTE UNITS A. FIBER PLANNING IS DONE ;MIT THE INSTALLATION OF TWO PARALLEL SYSTEMS. ONE SYSTEM WILL SUPPORT R AND PCS; THE OTHER SYSTEM WILL SUPPORT CELL AND PCS. ONLY THE CELL/PCS SYSTEM IS BEING INSTALLED AT THIS TIME B. IN GENERAL, THE CABLE SCHEDULE GOES FROM THE TFLN CARD IN IBRACK (IN MAIN CABINET) TOWARDS THE RU AS THE TABLE READS FROM LEFT RIGHT. C. FIBER BUNDLES COMING AGGREGATION POINTS / CEDED WITH "F „' D. FIBER BUNDLES COMING U's HAVE 6 FIBERS, AND IN THE SCHEDULE ARE PRECEDED WITH "R”. E. FIBER CONNECTORS ARE 'LACED ON ALL FIBERS WITH FROM/TO INFORMATION CALLED OUT IN THE SCHEDULE ABOVE, INCLUDING THOSE LISTE ARES. F. ALL 6- STRAND FIBER BUNDLES THAT RUN FROM THE FAP TO THE F ALSO INCLUDE (6) #16 AWG CC CABLES AS PART OF THE CABLE BLIP G. FIBER IN SCHEDULE SHO - -- _R■Y ARE TO BE LABELED AND STORED WITH CONNECTORS. H. FIBERS SHOULD BE FITTED WITH CONNECTORS AND LEFT COILED IN THE 12" x 18" PULL BOXES NEXT TO EACH RU. FIBER NUMBER FROM TO FIBER NUMBER FROM TO BUNDLE NUMBER FIBER NUMBER FROM TO EQUIPMENT PORT EQUIPMENT PORT EQUIPMENT PORT EQUIPMENT PORT EQUIPMENT PORT EQUIPMENT PORT F 1 SLOT 7 TFLN 1 UL MAIN CABINET SPLICE TRAY 1 F 1 MAIN CABINET SPLICE TRAY 1 FAP#2 SPLICE TRAY 1 R4 -1 1 FAP#2 SPLICE TRAY 25 SYSTEM A RU 4 -1 UL F 2 SLOT 7 TFLN 1 DL MAIN CABINET SPLICE TRAY 2 F 2 MAIN CABINET SPLICE TRAY 2 FAP#2 SPLICE TRAY 2 2 FAP#2 SPLICE TRAY 26 SYSTEM A RU 4 -1 DL F3 MAIN CABINET SPLICE TRAY 3 F3 MAIN CABINET SPLICE TRAY 3 FAP#2 SPLICE TRAY 3 3 FAP#2 SPLICE TRAY 27 SPARE 41 NOTE 'ROJECT INFORMATION F 4 MAIN CABINET SPLICE TRAY 4 F 4 MAIN CABINET SPLICE TRAY 4 FAP#2 SPLICE TRAY 4 4 FAP#2 SPLICE TRAY 28 SPARE 4 -1 NOTE H SOUTHCENTER F5 MAIN CABINET SPLICE TRAY 5 F 5 MAIN CABINET SPLICE TRAY 5 FAP#2 SPLICE TRAY 5 5 FAP#2 SPLICE TRAY 29 SPARE 4-1 NOTE H F6 MAIN CABINET SPLICE TRAY 6 F6 MAIN CABINET SPLICE TRAY 6 FAP#2 SPLICE TRAY 6 6 FAP1/2 SPLICE TRAY 30 SPARE 4.1 NOTE 633 SOUTHCENTER MALL SEATTLE,WA 98188 F7 SLOT 7 TFLN 2 UL MAIN CABINET SPLICE TRAY 7 F7 MAIN CABINET SPLICE TRAY 7 FAP #2 SPLICETRAV 7 R4 -2 1 FAP#2 SPLICE TRAY 31 SYSTEM A RU 4-2 UL F 8 SLOT 7 TFLN 2 DL MAIN CABINET SPLICE TRAY 8 F 8 MAIN CABINET SPLICE TRAY 8 FAP#2 SPLICE TRAY 8 2 FAP#2 SPLICE TRAY 32 SYSTEM A RU 4 -2 DL F 9 MA IN CABINET SPLICE TRAY 9 F9 MAI CABINET SPLICE TRAY 9 FAP#2 SPLICE TRAY 9 3 FAP# SPLICE TRAY 33 SPARE 4 -2 NOTE H SITE ID: 344199 F 10 MAIN CABINET SPLICE TRAY 10 F 10 MAIN CABINET SPLICE TRAY 10 FAP #2 SPLICE TRAY 10 4 FAP#2 SPLICE TRAY 34 SPAR 4 -2 NOTE H F11 MAIN CABINET SPLICE TRAY 11 F11 MAIN CABINET SPLICE TRAY 11 FAP#2 SPLICE TRAY 11 5 FAP#2 SPLICE TRAY 35 SPARE 42 NOTE H CURRENT ISSUE DATE F 12 MAIN CABINET SPLICE TRAY 12 F 12 MAIN CABINET SPLICE TRAY 12 FAP#2 SPLICE TRAY 12 6 FAP#2 SPLICE TRAY 36 SPARE 4 2 NOTE H r F 13 SLOT 7 TFLN 3 UL MAIN CABINET SPLICE TRAY 13 F 13 MAIN CABINET SPLICE TRAY 13 FAP#2 SPLICE TRAY 13 R4 - 3 1 FAP#2 SPLICE TRAY 31 SYSTEM A RU 4 - 3 UL (' 11 /19/2007 L F 14 SLOT 7 TFLN 3 DL MAIN CABINET SPLICE TRAY 14 F 14 MAIN CABINET SPLICE TRAY 14 FAP#2 SPLICE TRAY 14 2 FAP#2 SPLICE TRAY 32 SYSTEM A RU 4 - 3 DL F 15 MAIN CABINET SPLICE TRAY 15 F 15 MAIN CABINET SPLICE TRAY 15 FAP#2 SPLICE TRAY 15 3 FAP#2 SPLICE TRAY 33 SPARE 4.3 NOTE H F 16 MAIN CABINET SPLICE TRAY 16 F 16 MAIN CABINET SPLICE TRAY 16 FAP#2 SPLICE TRAY 16 4 FAP#2 SPLICE TRAY 34 SPARE 4 3 NOTE H ISSUED FOR F17 MAIN CABINET SPLICE TRAY 17 F17 MAIN CABINET SPLICE TRAY 17 FAP#25PLICETRAY 17 5 FAP#2SPLICETRAV 35 SPHKE4- NOTE H CONSTRUCTION F18 MAIN CABINET SPLICE TRAY 18 F18 MAIN CABINET SPLICE TRAY 18 FAP#2 SPLICE TRAY 18 6 FAP#2 SPLICE TRAY 36 SPARE 43 NOTE F 19 SLOT 7 TFLN 4 UL MAIN CABINET SPLICE TRAY 19 F 19 MAIN CABINET SPLICE TRAY 19 FAP #2 SPLICE TRAY 19 R4 1 FAP#2 SPLICE TRAY 31 SYSTEM A RU 4 UL F 20 SLOT 7 TFLN 4 DL MAIN CABINET SPLICE TRAY 20 F 20 MAIN CABINET SPLICE TRAY 20 FAP#2 SPLICE TRAY 20 2 FAP#2 SPLICE TRAY 32 SYSTEM A RU 44 DL ISSUED FOR Y _REV. 0 06/19/2007 PRELIMINARY ACS F 21 MAIN CABINET SPLICE TRAY 21 F 21 MAIN CABINET SPLICE TRAY 21 FAP#2 SPLICE TRAY 21 3 FAP#2 SPLICE TRAY 33 SPARE_ 4-4 NOTE F22 MAIN CABINET SPLICE TRAY 22 F22 MAIN CABINET SPLICE TRAY 22 FAP#2 SPLICE TRAY '22 4 FAP#2 SPLICE TRAY 34 SPARE 44 NOTEH F23 MAIN CABINET SPLICE TRAY 23 F23 MAIN CABINET SPLICE TRAY 23 FAP#2 SPLICE TRAY 23 5 FAP#2 SPLICE TRAY 35 SPARS 44 NOTE 1 06/21/2007 OWNER APPROVAL ACS F 24 MAIN CABINET SPLICE TRAY 24 F 24 MAIN CABINET SPLICE TRAY 24 FAP#2 SPLICE TRAY 24 6 FAP#2 SPLICE TRAY 36 SPARE 4 -4 NOTE H 2 09/10/2007 PRELIMINARY ACS PHASE #2 ® • ® ® F 25 MAIN CABINET SPLICE TRAY 25 FAP#2 SPLICE TRAY 25 R5 - 1 1 FAP#1 SPLICE TRAY 31 SYSTEM A RU 5 - 1 UL 3 09/26/2007 OWNER APPROVAL ACS � • ® • 0 F 26 MAIN CABINET SPLICE TRAY 26 FAP#2 SPLICE TRAY 26 2 FAP #1 SPLICE TRAY 32 SYSTEM A RU 5 - 1 DL ® - ® 0 F 27 MAIN CABINET SPLICE TRAY 27 FAP#2 SPLICE TRAY 27 3 FAP#1 SPLICE TRAY 33 SHAKE 5 NOTE H 4 11/052007 CONSTRUCTION ACS F 28 MAIN CABINET SPLICE TRAY 28 FAP#2 SPLICE TRAY 28 4 FAP #1 SPLICE TRAY 34 SPARE ■-1 NOTE 5 11/19/2007 CONSTRUCTION ACS F 29 MAIN CABINET SPLICE TRAY 29 FAP#2 SPLICE TRAY 29 5 FAP #1 SPLICE TRAY 35 SPAR J -1 NOTE H MM F 30 MAIN CABINET SPLICE TRAY 30 FAP#2 SPLICE TRAY 30 6 FAP#1 SPLICE TRAY 36 SFH KE J -i NOTE H ® 1■REMMIE=IEEIN CI=IIMM F 31 MAIN CABINET SPLICE TRAY 31 FAP#2 SPLICE TRAY 31 R5 1 FAP#1 SPLICE TRAY 31 SYSTEM A RU 5 - 2 UL ® SLOT 8 TFLN NEM =HMI F 32 MAIN CABINET SPLICE TRAY 32 FAP#2 SPLICE TRAY 32 2 FAP 1$1 SPLICE TRAY 32 SYSTEM A RU 5 -2 DL F 33 MAIN CABINET SPLICE TRAY 33 FAP#2 SPLICE TRAY 33 3 FAP#1 SPLICE TRAY 33 S-A J L NOTE H IEEMIMMMMMMOMMIIMNIII ® EMI ® F 34 MAIN CABINET SPLICE TRAY 34 FAP#2 SPLICE TRAY 34 4 FAP#1 SPLICE TRAY 34 5I J, NOTE H F 35 MAIN CABINET SPLICE TRAY 35 FA2 SPLICE TRAY Po 35 5 FAP#1 SPLICE TRAY 35 A 5KKL J - 2 NOTE H �� er'y 'i I LJ I rr. al` .. . -. F 37 YaY'...ame Jam..ia MAIN CABINET SPLICE TRAY 37 Am. :liras' i'ii Am. FAP2 SPLICE TY ANC 37 ■ IMM R5 .ice . a/00. 1 Aii. r'ia.'dm. Am.' F#1 SPLICE TRAY 31 SYSTEM A RU 5 - 3 !ay UL F 38 MAIN CABINET SPLICE TRAY 38 FAP#2 SPLICE TRAY 38 2 FAP#1 SPLICE TRAY 32 SYSTEM A RU 5 - 3 DL F 39 MIN CABINET SPLICE TRAY 39 FAP2 SPLICE TRAY 39 3 FAP#1 SPLICE TRAY 33 $ - AE J . NOTE H — F 40 MAIN CABINET SPLICETRAV 40 FP#2 SPLICE TRAY 40 4 FA#1 SPLICE TRAY 34 Si 'AKL `: NOTE H — PLANS PREPARED BY F 41 MAIN CABINET SPLICE TRAY 41 FAP1/2 SPLICE TRAY 41 5 FAP#1 SPLICE TRAY 35 ,t ,t: :, .t NOTE H — F 42 MAIN CABINET SPLICE TRAY 42 FAP#2 SPLICE TRAY 42 6 FAP#1 SPLICE TRAY 36 NOTE H F 43 SLOT 8 TFLN 4 UL MAIN CABINET SPLICE TRAY 43 F 43 MAIN CABINET SPLICE TRAY 43 FAP#2 SPLICE TRAY 43 1 1 FAP#1 SPLICE TRAY 31 SYSTEM A RU 5 UL F 44 SLOT 8 TFLN 4 DL MAIN CABINET SPLICE TRAY 44 F 44 MAIN CABINET SPLICE TRAY 44 FAP#2 SPLICE TRAY 44 ,w= FAP #1 SPLICE TRAY 32 SYSTEM A RU 5 DL F 45 MAIN CABINET SPLICE TRAY 45 F 45 MAIN CABINET SPLICE TRAY 45 FAP#2 SPLICE TRAY 45 Im FAP#1 SPLICE TRAY 33 L J •I NOTE H F 46 MAIN CABINET SPLICE TRAY 46 F 46 MAIN CABINET SPLICE TRAY 46 FAP#2 SPLICE TRAY 46 ,w= FAP#1 SPLICE TRAY 34 s ,r-t. , . NOTE H F 47 MAIN CABINET SPLICE TRAY 47 F 47 MAIN CABINET SPLICE TRAY 47 FAP#2 SPLICE TRAY 47 rion. FAP #1 SPLICE TRAY 35 i-A - L : 4 NOTE H F 48 MAIN CABINET SPLICE TRAY 48 F 48 MAIN CABINET SPLICE TRAY 48 FAP#2 SPLICE TRAY 48 `v FAP1t1 SPLICE TRAY 36 :sPAKL b 4 NOTE H OTICE American Tower Corporation Proprietary and Confidential ®2007. Intended for limited use by employees and agents only while performing work for American Tower. Not to be distributed without the express wdtten consent of American Tower Corporation. CO F 49 SLOT 9 TFLN 1 UL MAIN CABINET SPLICE TRAY 49 F 49 MAIN CABINET SPLICE TRAY 49 FAP#2 SPLICE TRAY 49 ,S FAP#1 SPLICE TRAY 31 SYSTEM A RU 6 - 1 UL F 50 SLOT 9 TFLN 1 DL MAIN CABINET SPLICE TRAY 50 F 50 MAIN CABINET SPLICE TRAY 50 FAP#2 SPLICE TRAY 50 r© FAP#1 SPLICE TRAY 32 SYSTEM A RU 6 - 1 DL It F 51 MAIN CABINET SPLICE TRAY 51 F 51 MAIN CABINET SPLICE TRAY 51 FAP#2 SPLICE TRAY 51 ,© FAP#1 SPLICE TRAY 33 sPAIRL n 1 NOTE H F 52 MAIN CABINET SPLICE TRAY 52 F 52 MAIN CABINET SPLICE TRAY 52 FAP#2 SPLICE TRAY 52 m FAP#1 SPLICE TRAY 34 S P /i n i NOTE H III F 53 MAIN CABINET SPLICE TRAY 53 F 53 MAIN CABINET SPLICE TRAY 53 FAP #2 SPLICE TRAY 53 gum FAP#1 SPLICE TRAY 35 St'ti \r,L ti NOTE H CO F 54 MAIN CABINET SPLICE TRAY 54 F 54 MAIN CABINET SPLICE TRAY 54 FAP#2 SPLICE TRAY 54 WEE FAP #1 SPLICE TRAY 36 P' L o. 1 NOTE H F 55 SLOT 9 TFLN 2 UL MAIN CABINET SPLICE TRAY 55 F 55 MAIN CABINET SPLICE TRAY 55 FAPII2 SPLICE TRAY 55 III= FAP#1 SPLICE TRAY 31 SYSTEM A RU 6 -2 UL Q F 56 SLOT 9 TFLN 2 DL MAIN CABINET SPLICE TRAY 56 F 56 MAIN CABINET SPLICE TRAY 56 FAP#2 SPLICE TRAY 56 ,BENI FAP#1 SPLICE TRAY 32 SYSTEM A RU 6 -2 DL I F 57 MAIN CABINET SPLICE TRAY 57 F 57 MAIN CABINET SPLICE TRAY 57 FAP#2 SPLICE TRAY 57 ,� FAP#1 SPLICE TRAY 33 SP \Kt n NOTE H F 58 MAIN CABINET SPLICE TRAY 58 F SB MAIN CABINET SPLICE TRAY 58 FAP #2 SPLICE TRAY 58 , FAP#1 SPLICE TRAY 34 S - L p - L NOTE H DRAWN BY: CHK _APV o_ F 59 MAIN CABINET SPLICE TRAY 59 F 59 MAIN CABINET SPLICE TRAY 59 FAP#2 SPLICE TRAY 59 \© FAP#1 SPLICE TRAY 35 _; PAI,L NOTE H I A. SLAA I JMD I RF I F 60 MAIN CABINET SPLICE TRAY 60 F 60 MAIN CABINET SPLICE TRAY 60 FAP#2 SPLICE TRAY 60 ■S FAP#1 SPLICE TRAY 36 S -'A- L n r NOTE H F 61 SLOT 9 TFLN 3 UL MAIN CABINET SPLICE TRAY 61 F 61 MAIN CABINET SPLICE TRAY 61 FAP#2 SPLICE TRAY 61 r0 FAP#1 SPLICE TRAY 31 SYSTEM A RU 6 - 3 UL _LICENSURE F 62 SLOT 9 TFLN 3 DL MAIN CABINET SPLICE TRAY 62 F 62 MAIN CABINET SPLICE TRAY 62 FAP#2 SPLICE TRAY 62 '© FAP#1 SPLICE TRAY 32 SYSTEM A RU 6 - 3 DL q � Y �' DEC 2 4 2007 OaP_2h117 F 63 MAIN CABINET SPLICE TRAY 63 F 63 MAIN CABINET SPLICE TRAY 63 FAP#2 SPLICE TRAY 63 r© FAP #1 SPLICE TRAY 33 Sf'AKL h-2 NOTE H F 64 MAIN CABINET SPLICE TRAY 64 F 64 MAIN CABINET SPLICE TRAY 64 FAP #2 SPLICE TRAY 64 '� FAP#1 SPLICE TRAY 34 SPARE fi -:' NOTE H F 65 MAIN CABINET SPLICE TRAY 65 F 65 MAIN CABINET SPLICE TRAY 65 FAP #2 SPLICE TRAY 65 Irmo. FAP#1 SPLICE TRAY 35 :i f'AKL ti -2 NOTE H F 66 MAIN CABINET SPLICE TRAY 66 F 66 MAIN CABINET SPLICE TRAY 66 FAP #2 SPLICE TRAY 66 I 6 FAP#1 SPLICE TRAY 36 SPARE NOTE H F 67 SLOT 9 TFLN 4 UL MAIN CABINET SPLICE TRAY 67 F 67 MAIN CABINET SPLICE TRAY 67 FAP#2 SPLICE TRAY 67 FIBER FROM SPLICE TRAY IN FIBER BUNDLE FROM FRONT OF PATCH PANEL F 68 SLOT 9 TFLN 4 DL MAIN CABINET SPLICE TRAY 68 F 68 MAIN CABINET SPLICE TRAY 68 FAP #2 SPLICE TRAY 68 MAIN HUB CABINET TO SPLICE F 69 MAIN CABINET SPLICE TRAY 69 F 69 MAIN CABINET SPLICE TRAY 69 FAP#2 SPLICE TRAY 69 TRAY IN AGGREGATE POINT © F 70 MAIN CABINET SPLICE TRAY 70 F 70 MAIN CABINET SPLICE TRAY 70 FAP#2 SPLICE TRAY 70 F 71 MAIN CABINET SPLICETRAV F 71 MAIN CABINET SPLICETRAV 71 FAP #2 SPLICE rRAV 71 RENUMBERED = SHEET TITLE - ' - "" ' F 72 MAIN CABINET SPLICE T 72 F 72 MAIN CABINET SPLICE TRAY 72 FAP#2 SPLICE TRAY 72 / NOTES &ILLUSTRATION FIBER SCHEDULE FAP #2 FIBER FROM TLFN CARDS IN ACTIVE O ��G SUBRACK TO FIBER SPLICE TRAY ` � V j © FIBER SPLICE TRAY Y V , 1 - � IN AGGREGATE POINT TO UPLINK AND DOWNLINK OF REMOTE UNIT. 1 FIBER C O P P E R P IS6FIBER & 3 CPPER PAIR. - — SHEET NUMBER. REVISION_ ADDING 5 -3 IN (PP) �' ` ///'��_ D V 5 - .\-‘ \" �pO FOOD COURT MAIN HUB FIBER REMOTE Pk" CABINET (MHUB) AGGREGATE UNIT POINT (FAP) (RU) AMMIIRICAN TOVIIIIR 1-# 2SVHd TFLN CARDS TO MAIN SPLICE TRAY IN CABINET MAIN SPLICE TO FIBER AGGREGATE POINT #1 SPLICE TRAY FIBER AGGREGATE POINT #1 SPLICE TRAY TO REMOTE UNITS FIBER NUMBER FROM TO FIBER NUMBER FROM TOI BUNDLE NUMBER FIBER NUMBER FROM TO EQUIPMENT PORT EQUIPMENT PORT EQUIPMENT PORT EQUIPMENT . PORT EQUIPMENT PORT EQUIPMENT PORT F 1 SLOT 1 TFLN 1 UL MAIN CABINET SPLICE TRAY 1 F 1 MAIN CABINET SPLICE TRAY 1 FAP#1 SPLICE TRAY 1 R1 - 1 1 FAP#1 SPLICE TRAY 1 SYSTEM A RU 1.1 UL F 2 SLOT 1 TFLN 1 DL MAIN CABINET SPLICE TRAY 2 F 2 MAIN CABINET SPLICE TRAY 2 FAP#1 SPLICE TRAY 2 2 FAP #1 SPLICE TRAY 2 SYSTEM A RU 1 DL F 3 MAIN CABINET SPLICE TRAY 3 F 3 MAIN CABINET SPLICE TRAY 3 FAP#1 SPLICE TRAY 3 3 FAP#1 SPLICE TRAY 3 SPARE 1 -1 NOTE H • ROJECT INFORMATION F4 MAIN CABINET SPLICE TRAY 4 F4 MAIN CABINET SPLICE TRAY 4 FAP#1 SPLICE TRAY 4 4 FAP#1 SPLICE TRAY 4 SPARE 1 -2 NOTE H SOUTHCENTER F 5 MAIN CABINET SPLICE TRAY 5 F 5 MAIN CABINET SPLICE TRAY 5 FAP#1 SPLICE TRAY 5 5 FAP#1 SPLICE TRAY 5 SPARE 1 -1 NOTE H F 6 MAIN CABINET SPLICE TRAY 6 F 6 MAIN CABINET SPLICE TRAY 6 FAP#1 SPLICE TRAY 6 6 FAP#1 SPLICE TRAY 6 SPARE 1 -2 NOTE H 633 SOUTHCENTER MALL SEATTLE,WA 98188 F 7 SLOT 1 TFLN 2 UL MAIN CABINET SPLICE TRAY 7 F 7 MAIN CABINET SPLICE TRAY 7 FAP#1 SPLICE TRAY 7 R1 - 2 1 FAP#1 SPLICE TRAY 7 SYSTEM A RU 1 - 2 UL F 8 SLOT 1 TFLN 2 DL MAIN CABINET SPLICE TRAY 8 F 8 MAIN CABINET SPLICE TRAY 8 FAP#1 SPLICE TRAY 8 2 FAP#1 SPLICE TRAY 8 SYSTEM A RU 1 - 2 DL SITE ID: 344199 F 9 MAIN CABINET SPLICE TRAY 9 F 9 MAIN CABINET SPLICE TRAY 9 FAP#1 SPLICE TRAY 9 3 FAP#1 SPLICE TRAY 9 SPARE 1 -2 NOTE H F 10 MAIN CABINET SPLICE TRAY 10 F 10 MAIN CABINET SPLICE TRAY 10 FAP#1 SPLICE TRAY 10 4 FAP#1 SPLICE TRAY 10 SPARE 1 -2 NOTE H CURRENT ISSUE DATE. F 11 MAIN CABINET SPLICE TRAY 11 F 11 MAIN CABINET SPLICE TRAY 11 FAP#1 SPLICE TRAY 11 5 FAP #1 SPLICE TRAY 11 SPARE 1 -2 NOTE H 11/ 19/2007 F 12 MAIN CABINET SPLICE TRAY 12 F 12 MAIN CABINET SPLICE TRAY 12 FAP #1 SPLICE TRAY 12 6 FAP#1 SPLICE TRAY 12 SPARE 1-2 NOTE F 13 SLOT 1 TFLN 3 UL MAIN CABINET SPLICE TRAY 13 F 13 MAIN CABINET SPLICE TRAY 13 FAP#1 SPLICE TRAY 13 R1 - 3 1 FAP#1 SPLICE TRAY 13 SYSTEM A RU 1 - 3 UL F 14 SLOT 1 TFLN 3 DL MAIN CABINET SPLICE TRAY 14 F 14 MAIN CABINET SPLICE TRAY 14 FAP#1 SPLICE TRAY 14 2 FAP#1 SPLICE TRAY 14 SYSTEM A RU 1 - 3 DL ISSUED FOR F 15 MAIN CABINET SPLICE TRAY 15 F 15 MAIN CABINET SPLICE TRAY 15 FAP#1 SPLICE TRAY 15 3 FAP#1 SPLICE TRAY 15 SPARE 1 -3 NOTE H t I CONSTRUCTION F 16 MAIN CABINET SPLICE TRAY 16 F 16 MAIN CABINET SPLICE TRAY 16 FAP#1 SPLICE TRAY 16 4 FAP#1 SPLICE TRAY 16 SPARE 1,3 NOTE H F 17 MAIN CABINET SPLICE TRAY 17 F 17 MAIN CABINET SPLICE TRAY 17 FAP #1 SPLICE TRAY 17 5 FAP#1 SPLICE TRAY 17 SPARE NOTE REV. FOR F 18 MAIN CABINET SPLICE TRAY 18 F 18 MAIN CABINET SPLICE TRAY 18 FAP#1 SPLICE TRAY 18 6 FAP #1 SPLICE TRAY 18 SPARE 1 ,3 NOTE H 0 06/192007 PRELIMINARY BY ACS F 19 SLOT 1 TFLN 4 UL MAIN CABINET SPLICE TRAY 19 F 19 MAIN CABINET SPLICE TRAY 19 FAP#1 SPLICE TRAY 19 R1 - 4 1 FAP#1 SPLICE TRAY 19 SYSTEM A RU 1 UL F 20 SLOT 1 TFLN 4 DL MAIN CABINET SPLICE TRAY 20 F 20 MAIN CABINET SPLICE TRAY 20 FAP#1 SPLICE TRAY 20 2 FAP#1 SPLICE TRAY 20 SYSTEM A RU 1 DL 1 0621/2007 OWNER APPROVAL ACS F 21 MAIN CABINET SPLICE TRAY 21 F 21 MAIN CABINET SPLICE TRAY 21 FAP#1 SPLICE TRAY 21 3 FAP#1 SPLICE TRAY 21 SPARE 1 -4 NOTE H F 22 MAIN CABINET SPLICE TRAY 22 F 22 MAIN CABINET SPLICE TRAY 22 FAP#1 SPLICE TRAY 22 4 FAP#1 SPLICE TRAY 22 SPARE 1 -4 NOTE H 2 09/10/2007 PRELIMINARY ACS F 23 MAIN CABINET SPLICE TRAY 23 F 23 MAIN CABINET SPLICE TRAY 23 FAP#1 SPLICE TRAY 23 5 FAP#1 SPLICE TRAY 23 SPARE 1-4 NOTE 11 F 24 MAIN CABINET SPLICE TRAY 24 F 24 MAIN CABINET SPLICE TRAY 24 - FAP#1 SPLICE TRAY 24 6 FAP#1 SPLICE TRAY 24 SPARE 1 -4 NOTE 11 3 09/26/2007 OWNER APPROVAL ACS 4 11/05/2007 CONSTRUCTION ACS PHASE #2 F 25 SLOT 2 TFLN 1 UL MAIN CABINET SPLICE TRAY 25 F 25 MAIN CABINET SPLICE TRAY 25 FAP#1 SPLICE TRAY 25 R2 - 1 1 FAP #1 SPLICE TRAY 25 SYSTEM A RU 2 - 1 UL 5 11/19/2007 CONSTRUCTION ACS F 26 SLOT 2 TFLN 1 DL MAIN CABINET SPLICE TRAY 26 F 26 MAIN CABINET SPLICE TRAY 26 FAP#1 SPLICE TRAY 26 2 FAP#1 SPLICE TRAY 26 SYSTEM A RU 2 - 1 DL F 27 MAIN CABINET SPLICE TRAY 27 F 27 MAIN CABINET SPLICE TRAY 27 FAP#1 SPLICE TRAY 27 3 FAP#1 SPLICE TRAY 27 SPARE 2 -1 NOTE H F 28 MAIN CABINET SPLICE TRAY 28 F 28 MAIN CABINET SPLICE TRAY 28 FAP#1 SPLICE TRAY 28 4 FAP#1 SPLICE TRAY 28 SPARE 2 -1 NOTE H F 29 MAIN CABINET SPLICE TRAY 29 F 29 MAIN CABINET SPLICE TRAY 29 FAP#1 SPLICE TRAY 29 5 FAP#1 SPLICE TRAY 29 S PARE 2 -1 NOTE H F 30 MAIN CABINET SPLICE TRAY 30 F 30 MAIN CABINET SPLICE TRAY 30 FAP#1 SPLICE TRAY 30 6 FAP#1 SPLICE TRAY 30 5PARE 2-1 NOTE H F 31 SLOT 2 TFLN 2 UL MAIN CABINET SPLICE TRAY 31 F 31 MAIN CABINET SPLICE TRAY 31 FAP#1 SPLICE TRAY 31 R2 - 2 1 FAP#1 SPLICE TRAY 31 SYSTEM A RU 2 - 2 UL F 32 SLOT 2 TFLN 2 DL MAIN CABINET SPLICE TRAY 32 F 32 MAIN CABINET SPLICE TRAY 32 FAP#1 SPLICE TRAY 32 2 FAP#1 SPLICE TRAY 32 SYSTEM A RU 2 - 2 DL F 33 MAIN CABINET SPLICE TRAY 33 F 33 MAIN CABINET SPLICE TRAY 33 FAP#1 SPLICE TRAY 33 3 FAP#1 SPLICE TRAY 33 SPARE 2 -2 NOTE 11 F 34 MAIN CABINET SPLICE TRAY 34 F 34 MAIN CABINET SPLICE TRAY 34 FAP#1 SPLICE TRAY 34 4 FAP#1 SPLICE TRAY 34 SPARE 2 -2 NOTE 11 F 35 MAIN CABINET SPLICE TRAY 35 F 35 MAIN CABINET SPLICE TRAY 35 FAP #1 SPLICE TRAY 35 5 FAP#1 SPLICE TRAY 35 SPARE 2 -2 NOTE H — PLANS PREPARED BY F 36 MAIN CABINET SPLICE TRAY 36 F 36 MAIN CABINET SPLICE TRAY 36 FAP #1 SPLICE TRAY 36 6 FAP #1 SPLICE TRAY 36 SPARE ' -2 NOTE H F 37 SLOT 2 TFLN 3 UL MAIN CABINET SPLICE TRAY 37 F 37 MAIN CABINET SPLICE TRAY 37 FAP#1 SPLICE TRAY 37 R2 - 3 1 FAP #1 SPLICE TRAY 31 SYSTEM A RU 2 - 3 UL F 38 SLOT 2 TFLN 3 DL MAIN CABINET SPLICE TRAY 38 F 38 MAIN CABINET SPLICE TRAY 38 FAP #1 SPLICE TRAY 38 2 FAP #1 SPLICE TRAY 32 SYSTEM A RU 2 - 3 DL F 39 MAIN CABINET SPLICE TRAY 39 F 39 MAIN CABINET SPLICE TRAY 39 FAP#1 SPLICE TRAY 39 3 FAP #1 SPLICE TRAY 33 SPARE 2 -3 NOTE H F 40 MAIN CABINET SPLICE TRAY 40 F 40 MAIN CABINET SPLICE TRAY 40 FAP#1 SPLICE TRAY 40 4 FAP #1 SPLICE TRAY 34 SPARE 2 -3 NOTE H F 41 MAIN CABINET SPLICE TRAY 41 F 41 MAIN CABINET SPLICE TRAY 41 FAP#1 SPLICE TRAY 41 5 FAP#1 SPLICE TRAY 35 SPARE 2 -3 NOTE H F 42 MAIN CABINET SPLICE TRAY 42 F 42 MAIN CABINET SPLICE TRAY 42 FAP#1 SPLICE TRAY 42 6 FAP#1 SPLICE TRAY 36 SPARE. 2 -3 NOTE H OTICE F 43 SLOT 2 TFLN 4 UL MAIN CABINET SPLICE TRAY 43 F 43 MAIN CABINET SPLICE TRAY 43 FAP#1 SPLICE TRAY 43 R2 - 4 1 FAP#1 SPLICE TRAY 31 SYSTEM A RU 2 UL American Tower Corporation Proprietary and Confidential ®2007. Intended for limited use by employees and agents only while performing work for American Tower. Not to be distributed without the express written consent of American Tower Corporation. F 44 SLOT 2 TFLN 4 DL MAIN CABINET SPLICE TRAY 44 F 44 MAIN CABINET SPLICE TRAY 44 FAP#1 SPLICE TRAY 44 2 FAP#1 SPLICE TRAY 32 SYSTEM A RU 2 DL F 45 MAIN CABINET SPLICE TRAY 45 F 45 MAIN CABINET SPLICE TRAY 45 FAP#1 SPLICE TRAY 45 3 FAP#1 SPLICE TRAY 33 SPARE 2.4 NOTE H F 46 MAIN CABINET SPLICE TRAY 46 F 46 MAIN CABINET SPLICE TRAY 46 FAP#1 SPLICE TRAY 46 4 FAP#1 SPLICE TRAY 34 SPARE 2 -4 NOTE H F 47 MAIN CABINET SPLICE TRAY 47 F 47 MAIN CABINET SPLICE TRAY 47 FAP#1 SPLICE TRAY 47 5 FAP#1 SPLICE TRAY 35 SPARE 2-4 NOTE H F 48 MAIN CABINET SPLICE TRAY 48 F 48 MAIN CABINET SPLICE TRAY 48 FAP#1 SPLICE TRAY 48 6 FAP#1 SPLICE TRAY 36 SPARE 2 -4 NOTE H 3 F 49 SLOT 3 TFLN 1 UL MAIN CABINET SPLICE TRAY 49 F 49 MAIN CABINET SPLICE TRAY 49 FAP#1 SPLICE TRAY 49 R3 - 1 1 FAP#2 SPLICE TRAY 1 SYSTEM A RU 3 - 1 UL F 50 SLOT 3 TFLN 1 DL MAIN CABINET SPLICE TRAY 50 F 50 MAIN CABINET SPLICE TRAY 50 FAP#1 SPLICE TRAY 50 2 FAP#2 SPLICE TRAY 2 SYSTEM A RU 3 - 1 DL F 51 MAIN CABINET SPLICE TRAY 51 F 51 MAIN CABINET SPLICE TRAY 51 FAP #1 SPLICE TRAY 51 3 FAP#2 SPLICE TRAY 3 SPARE 3 -1 NOTE H DRAWN BY CHK APV F 52 MAIN CABINET SPLICE TRAY 52 F 52 MAIN CABINET SPLICE TRAY 52 FAP #1 SPLICE TRAY 52 4 FAP#2 SPLICE TRAY 4 SP.AkE 3 -1 NOTE H I A. SLAA I JMD I RF I F 53 MAIN CABINET SPLICE TRAY 53 F 53 MAIN CABINET SPLICE TRAY 53 FAP#1 SPLICE TRAY 53 5 FAP#2 SPLICE TRAY 5 SPARE 3-1 NOTE H F 54 MAIN CABINET SPLICE TRAY 54 F 54 MAIN CABINET SPLICE TRAY 54 FAP #1 SPLICE TRAY 54 6 FAP #2 SPLICE TRAY 6 SPARE 3 -1 NOTE H _LICEN 9 s A' PIE _ DEC 2' 2007 PERMIT CENTEk-I F 55 SLOT 3 TFLN 2 UL MAIN CABINET SPLICE TRAY 55 F 55 MAIN CABINET SPLICE TRAY 55 FAP#1 SPLICE TRAY 55 R3 - 2 1 FAP#2 SPLICE TRAY 7 SYSTEM A RU 3 - 2 UL F 56 SLOT 3 TFLN 2 DL MAIN CABINET SPLICE TRAY 56 F 56 MAIN CABINET SPLICE TRAY 56 FAP#1 SPLICE TRAY 56 2 FAP#2 SPLICE TRAY 8 SYSTEM A RU 3 - 2 DL F 57 MAIN CABINET SPLICE TRAY 57 F 57 MAIN CABINET SPLICE TRAY 57 FAP #1 SPLICE TRAY 57 3 FAP#2 SPLICE TRAY 9 SPARE 3 -2 NOTE H F 58 MAIN CABINET SPLICE TRAY 58 F 58 MAIN CABINET SPLICE TRAY 58 FAP#1 SPLICE TRAY 58 4 FAP #2 SPLICE TRAY 10 SPARE "x -^ �y F 59 MAIN CABINET SPLICE TRAY 59 F 59 MAIN CABINET SPLICE TRAY 59 FAP#1 SPLICE TRAY 59 5 FAP #2 SPLICE TRAY 11 �� /- ''/ * R �Z.7Z�1 1 \ F 60 MAIN CABINET SPLICE TRAY 60 F 60 MAIN CABINET SPLICE TRAY 60 FAP#1 SPLICE TRAY 60 6 FAP #2 SPLICE TRAY 12 - z C � ICI : • yj �E F 61 SLOT 3 TFLN 3 UL MAIN CABINET SPLICE TRAY 61 F 61 MAIN CABINET SPLICE TRAY 61 FAP #1 SPLICE TRAY 61 _ � O L+ �J F 62 SLOT 3 TFLN 3 DL MAIN CABINET SPLICE TRAY 62 F 62 MAIN CABINET SPLICE TRAY 62 FAP #1 SPLICE TRAY 62 w NFP 70 — NEC ,v �A 1 1 2008 TIOf Fe'�TUI F 63 MAIN CABINET SPLICE TRAY 63 F 63 MAIN CABINET SPLICE TRAY 63 FAP #1 SPLICE TRAY 63 =SHEET TITLE F 64 MAIN CABINET SPLICE TRAY 64 F 64 MAIN CABINET SPLICE TRAY 64 FAP #1 SPLICE TRAY 64 FIBER SCHEDULE FAP #1 F 65 MAIN CABINET SPLICE TRAY 65 F 65 MAIN CABINET SPLICE TRAY 65 FAP#1 SPLICE TRAY 65 F 66 MAIN CABINET SPLICE TRAY 66 F 66 MAIN CABINET SPLICE TRAY 66 FAP#1 SPLICE TRAY 66 F 67 SLOT 3 TFLN 4 UL MAIN CABINET SPLICE TRAY 67 F 67 MAIN CABINET SPLICE TRAY 67 FAP#1 SPLICE TRAY 67 * F 68 SLOT 3 TFLN 4 DL MAIN CABINET SPLICE TRAY 66 F 68 MAIN CABINET SPLICE TRAY 68 FAP#1 SPLICE TRAY 68 SEE SHEET D6 FOR NOTES F 69 MAIN CABINET SPLICE TRAY 69 F 69 MAIN CABINET SPLICE TRAY 69 FAP#1 SPLICE TRAY 69 NUMBER. REVISION, F 70 MAIN CABINET SPLICE TRAY 70 F 70 MAIN CABINET SPLICE TRAY 70 FAP#1 SPLICE TRAY 70 * *SEE SHEET D6 FOR ILLUST =SHEET D 5 5 F 71 MAIN CABINET SPLICE TRAY 71 F 71 MAIN CABINET SPLICE TRAY 71 FAP #1 SPLICE TRAY 71 ROUTES F 72 MAIN CABINET SPLICE TRAY 72 F 72 MAIN CABINET SPLICE TRAY 72 FAP #1 SPLICE TRAY 72 BUILDING D SION • k T>diN�i NOTE: 1. ALL UNUSED SMA PORTS TO BE PROPERLY TERMINATED (W /SMA TERMINATORS) 2. SYSTEM IS DESIGNED FOR -14dBm PER RADIO INTO EACH TFLN DOWNLINK CONNECTOR ' ROJECT INFORMATION SOUTHCENTER COAX CABLE SCHEDULE SECTOR #1 PCS / SMR 633SOUTHCENTERMALL SEATTLE,WA 98188 O Q o 0 0 0 0 0 0 0 O O (ASR #1) ACTIVE SUBRACK (TPRN -14) (PSR #1) PASSIVE SUBRACK SECTOR 1 (TPRN -14) I TMP ) ( TLCN2 ) I TMP ) I TMP ) CABLE NUMBER FROM TO RF Rp OUT O we a `» q� U L oL O O 10 0 2 O 0 O IN RF OUT O -e a A —' O RF IN RF oU7 0 werwi - J SITE ID: 344199 PART PORT PART PORT NOTE: THIS ACTIVE SUBRACK INSTALLED AND CONNECTED TO POWER AND MONITORING EQUIPMENT. NO BRITECELL CARDS TO BE INSTALLED BY DASIC. CURRENT ISSUE DATE. 1 PSR #1 slot 1 TLCN4 UL C PSR #1 slot 3 TLDN high band UL 11/19/2007 I 2 PSR #1 slot 1 TLCN4 DL C PSR #1 slot 3 TLDN high band DL ISSUED FOR CONSTRUCTION 3 PSR #1 slot 2 TLCN2 UL C PSR #1 slot 3 TLDN low band UL 4 PSR #1 slot 2 TLCN2 DL C PSR #1 slot 3 TLDN low band DL DATE: ISSUED FOR BY _REV.: = 0 = 06/19/2007 PRELIMINARY ACS 5 PSR #1 slot 3 TLDN UL C PSR #1 slot 4 TLCN4 UL C 1 06/27/2007 OWNER APPROVAL ACS 6 PSR #1 slot 3 TLDN DL C PSR #1 slot 4 TLCN4 DL C 2 09/10 /2007 PRELIMINARY ACS 3 09 /26 /2007 OWNER APPROVAL ACS 7 PSR #1 slot 4 TLCN4 DL 1 ASR #2 slot 1 TFLN main DL 8 PSR #1 slot 4 TLCN4 UL 1 ASR #2 slot 1 TFLN main UL 4 11/05/2007 CONSTRUCTION ACS 9 PSR #1 slot 4 TLCN4 DL 2 ASR #2 slot 2 TFLN main DL o 0 o CD 0 0 0 5 11/19 /2007 CONSTRUCTION ACS O o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 10 PSR #1 slot 4 TLCN4 UL 2 ASR #2 slot 2 TFLN main UL ( TLCN4) I TLCN2 3 ( TLDN ) I TLCN4 ) ( TLCN4 ) (TLCN2 ) I TLDN ) (TLCN4) UL DL UL DL O 7 O> 5 UL DL t5-75) 19 UL DL � p�p1 11 PSR #1 slot 4 TLCN4 DL 1 ASR #2 slot 3 TFLN main DL -6 UL DL -20r UL I T1 D L - :OD 12 PSR #1 slot 4 TLCN4 UL 1 ASR #2 slot 3 TFLN main UL NO 1 -22 'O c0) r,OD0) _._ r —L 0 0 2 1 3 I o o 400 3-4 15 -16r — — 17 -11 HIGH BAND HIGH: 10 O 1 i O O JO 21 -26 _ D 0 - PLANS PREPARED BY 1 0 0 20 O OO �O 7 -12 2 0 10 O '' 20 0 'O O � 0 COAX CABLE SCHEDULE SECTOR #2 PCS / SMR I 3� o 400 SEE N — LOW ND 3 0 0 Li 30 0 CABLE FROM TO `O O` 40 O O 40 0 NUMBER PART PORT PART PORT SEE N •TE #1 TE #1 15 PSR #1 slot 7 TLCN4 UL C PSR #1 slot 9 TLDN high band UL OTICE American Tower Corporation Proprietary and Confidential ©2007. Intended for limited use by employees and agents only while performing work for American Tower. Not to be distributed without the express written consent of American Tower Corporation. 16 PSR #1 slot 7 TLCN4 DL C PSR #1 slot 9 TLDN high band DL O O O O O O O O O O O O O O O O 0 0 0 0 0 0 0 0 0 0 o 17 PSR #1 slot 8 TLCN2 UL C PSR #1 slot 9 TLDN low band UL ® ® ( TFLN ) ® ® ( TFLN ) 18 PSR #1 slot 8 TLCN2 DL C PSR #1 slot 9 TLDN low band DL r AUX MAN � _ AUX AA JN r AUX MAN AUX MAIN AUX MAIN o •• •!! O — = = — = = — UL'0' � DLO ' -2- — _ _ — o sift, •! O — _ _ — uL ! DL ' -2- O� 1 O _ — i i 0 ••I ••• O = - _ — _ _ — _ UL DL ' -2- j O:. = - _ — o oil ••• O = - _ — _ _ _ UL DL ' -2- -3- 4 Q O, = _ _ — _ _ 0 ••t ••• O = _ _ — _ _ a DLL/ ' -2- -3- 4 p I = _ — = _ _ REVIEWE FOR EODE COMP NEB E IVFP 70 �A 11 2008 \ Of Tukwa (AS R #2) ACTIVE SUBRACK�'V PCS SMR800 /900 (TPRN -14) 19 PSR #1 slot 9 TLDN UL C PSR #1 slot 10 TLCN4 UL C L BY: HK _APV 20 PSR #1 slot 9 TLDN DL C PSR #1 slot 10 TLCN4 DL C A. SLAA I JMD I RF I LICENSURE _ DEC 2'4 2001 PERMIT CENTEir. 21 PSR #1 slot 10 TLCN4 DL 1 ASR #2 slot 7 TFLN main DL 22 PSR #1 slot 10 TLCN4 UL 1 ASR #2 slot 7 TFLN main UL 23 PSR #1 slot 10 TLCN4 DL 2 ASR #2 slot 8 TFLN main DL 24 PSR #1 slot 10 TLCN4 UL 2 ASR #2 slot 8 TFLN main UL -3- 4 _ _ _ — _ _ - — -3- -4 _ _ -3- 4 = _ _ BUILDI � D LION • 25 PSR #1 slot 10 TLCN4 DL 1 ASR #2 slot 9 TFLN main DL 26 PSR #1 slot 10 TLCN4 UL 1 ASR #2 slot 9 TFLN main UL =SHEET TITLE BTS INTERFACE SYSTEM DRAWING 0 0 0 O o O O O o 0 0 O 1 2 3 4 5 6 7 8 9 10 11 12 (SLOT #) SECTOR #1 SECTOR #2 NUMBER. REVISION_ =SHEET D4 5 1 COAX JUMPER SCHEDULE 2 ACTIVE (POWERED) & PASSIVE SUB RACK COMPONENTS LEGEND: TOIMV� ,,C PCS /CELL OMNI ANTENNA PHASE 3 FUTURE EXPANSION OF .s PCS /SMR OMNI ANTENNA PROPOSED DIRECTIONAL ANTENNA DAS SYSTEM .1:P1 NODE •ROJECT INFORMATION C S M �C � s 3 -2 -t \ 32 l • - -2 ` /\ ` ` ON FOURTH LEVEL ,F m a 0 f1 S I' , OLR LEVELS J FUTURE RETAIL SOUTHCENTER II PROPOSED AGGREGATION POINT NM PROPOSED REMOTE UNIT I It J� 633SOUTHCENTERMALL SEATTLE,WA 98188 72 COMMUNICATIONS ROOM LOCATION SITE ID: 344199 — DUAL Y2 COAX RUN CURRENT ISSUE DATE 11/19/2007 I --- FIBER RUN 12 NEW ACCESS PANEL AS NEEDED ISSUED FOR CONSTRUCTION • 2 -0 -2 Li C S NORDSTROM THREE LEVELS ISSUED FOR: BY _REV. _DATE: 0 = 06/192007 PRELIMINARY ACS / �® / 1 06/21/2007 OWNER APPROVAL ACS 2 09/10/2007 PRELIMINARY ACS 3 4 5 09262007 11/05/2007 11/192007 OWNER APPROVAL CONSTRUCTION CONSTRUCTION ACS ACS ACS /--� / \ - - j JCPenney THREE LEVELS C S • • 6 -2 -2 ; f c - PLANS PREPARED BY -. . . -. i RENUMBERED C S C> • • • 6-3 -2 � 6 I I t 7 F e_ _ ■- " f -- 1 t 1 ti 1 - 1111111 ` 4 f l • I ' i — f , — f - m 1�1 _ 1 _ Iffnfll J t i f OHMS - •�` r ; • 1111 _ i ' II i 1 LEELS C 5 2 -3 -2 le 111 i�� '. L!__ IL. - DYKE ' P i ° REVI FOR CODE OP NE THRE NFPA - while performing work for American Tower. Not to be distributed without the express written consent of American Tower Corporation. � � J RENUMBERED L � _.� 1 I Aa .. K y o .. r � - 7 , \ L ' L u � �� ^ =' •4 �,.. ` 1 .I - --- = pp4 - -- - L I 'AI nri a,u . m .. ' x . a' - aft \ DRAWN BY HK PV ' i 1 _ OI A. SLAA JW I RF I ( LICENSURE l l , o` �1 ■H .7 ■� ■� I4 Of Tukwila ING DNISIO� • R, P3 09 r"d s = ��� 1 W,n ' r �.. a O - _ ill Bt1I � E ��' . DEC 2`'4 2007 PERMIT GENIE, ,� lipr \\ - • 1, Cr �: - _- — — —." �_, _ _„ _-. __ 6 �_ ._" - " �"t ��' ors - " - � 6. ----, " �' ��< SHEETTITLE O OO C) n ©� I lz fl�>� I,s-_ �.s DAS LAYOUT UPPER LEVEL PHASE 3 I I _'.- • 7 - - I I I I I I I I I I I I I I I I I I I I I I I I — SHEET NUMBER. REVISION — I D 3 5 S — b9 b9 b9 80 LEGEND: . PHASE 2 • C PCS /CELL OMNI ANTENNA .s PCS /SMR OMNI ANTENNA PROPOSED DIRECTIONAL ANTENNA MALL EXPANSION RENUMBERED ROJECT INFORMATION NODE MI PROPOSED AGGREGATION POINT IIII PROPOSED REMOTE UNIT C. . 5-4 5 -0 -2 s FUT r L S • 3-2-1a m , ' I (/�_ * 1 1 1�CyS = SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE,WA 98188 SITE ID: 344199 j� COMMUNICATIONS ROOM LOCATION CURRENT ISSUE DATE — DUAL Y2" COAX RUN -- FIBER RUN ►�� NEW ACCESS PANEL AS NEEDED 1 � 11/19/2007 li ISSUED FOR CONSTRUCTION • : 2-0 2 -0 -1b NORDSTROM ISSUED FOR BY _I _REV . iDATE: 0 = 06/19/2007 PRELIMINARY ACS \ / 1 06/11/1007 OWNER APPROVAL ACS / 2 09/10/2007 PRELIMINARY ACS \ /�I 3 09/26/1007 OWNER APPROVAL ACS \ � 7 1 4 11/05/2007 CONSTRUCTION ACS A 5 JVI Vf l y 11/19/2007 CONSTRUCTION ACS CORE IN ELEC. ROOM MOVED 5 -1 -1 CLOSER TO FOOD COURT. ADDED REMOTE UNIT 5 -3 CORE IN FOOD COURT - - c 6 -2 -1b s 6-2 .aeK aa - _ 9p o „ -r - 3. I ! r t` 9 F C !1 . © . y i • x , T • ""•�- -..- T C.M • - ` -PLANS PREPARED BY' Pt 1 1 . ll w� 1 - — — 3 ® .: 5 0 RENUMBERED ® c S 6 - 1b 6 3 a .•--. J h. r , • 6 .. 1 12, .. k C,ag ° • • 2 -*9,2T'�^R-^� • . 2u] r I :nsl 4 . -I .— 1 ( uvk �� L = 1 {, F . - � 1 x3_ I — S 2 -3 -tb w 2 - 3 ® ' -1 -1 : - ,�,- —,„ - - - _"�V 2 -T"— - 1 - � MI i.i4. r B2r ,rE I T . r I,� CODE CO ED FOR PLIANCE OTICE American Tower Corporation Proprietary and Confidential B 2007. Intended f or limited use by employees and agents only while performing work tor American Tower. Not to be distributed without the express written c onsent of American Tower Corporation. �° n u ''• 1014 r / 1: i ; , N - 'r 2 -� MN u p IL Lei : 1 1 , ;• � /gS� . 65 -`� p • / QAIf o d.d u° •� 2 -2 -2 « Rc s� g by .� BIB s1 N I „ Y.. } ++«. � t ma B ®'A 1 ∎ .. & g5 ' i W y' 1 ` . dll NEC �li fi•� ®11 ly 6® 00 ri '1 Ci S0Y , • n� ®HBq. ti h r II J `I g 2.1” 0 JAN 1 1 2008 91 ? s� — ®� > s 8 —: a 1 .a tract 1 ,, • r :C -- r . 4 A RM It ..:__ 887 sT *4 411 te r } , _ m ,r, . uMin M. DR,4W N BY: CHK _APV a"° ®: W -- '- ,o, ✓ „ .ARE" gb7 MI _ __ niii����l A. SL JW RF ILICENSURE ri 3 ��:� a !! 116i Ili ... 11 I .. lrt9� �•. ea �1 ® b � -\ � s0. p. l. ..922 Irca1 . gyp - • gr e a a ► Rfi:. -- -1 6i .,' g� ((�� c � � t � 'i` amC « t 1 W E MMDedr• ... ... C7 - 1 141 \Y�h Of Tukwila RECEIVE DEC 2'4 2007 pMfM T r .PIN.1 I — 4. "° '/ a h , NG DWISION ,4M �. — !� ii ��A ' , �'= .� � __ _ ._. -. , -s. .... a�Flce 4 t • _ � , bea�. , mai `` 1 r 11� - -� `' 4 b 4 4 4_ 4 4 - _ O .� K / a rt >< x_ .; � t! t?) Q d, ':' f 4 „ F• r x — SHEET TITLE - - L. V V Cr,' �`` @ u C z� e _ ( 2 rQ 4F • 1111 I I I I I I L1 CABLE NOTES: Q SOUTHCENTER UPPER LEVEL 0' 25 50' 100' DAS LAYOUT UPPER LEVEL PHASE2 • — — �. COAX: HL4RP -50 y " AIR DIELECTRIC PLENUM RATED (CATVP), HL-SERIES 50ohm AWG16 COPPER: BELDEN 6202UE - PLENUM COMMERCIAL AUDIO CABLE _. e 8 4 - -- 6 t = = I ALL CABLE TO BE PLENUM RATED FIBER: OPTICAL FIBER NONCONDUCTIVE PLENUM 6- CHANNEL: ATTENUATION 0.5 dB /km 36- CHANNEL: ATTENUATION 0.5 dB /km _ _ — — — flfl (A� I I l I I I I I I V I I I II I I NUMBER. REVISION_ — — _SHEET _ D 2 5 -� II 1 a6 — 16 64 LEGEND: PHASE 1 ,C PCS /CELL OMNI ANTENNA .s PCS /SMR OMNI ANTENNA PROPOSED DIRECTIONAL ANTENNA EXISTING MALL SPACE © I RENUMBERED NODE PROPOSED AGGREGATION POINT IN PROPOSED REMOTE UNIT •INFORMATION ROJEC SOUTHCENTER 3-1 �J ` W t / • l �• - 633 SOUTHCENTER MALL SEATTLE,WA98188 c c S 3-1.1 3 -1 -2 FU TU TAIL TWO LEVELS �»• l I / COMMUNICATIONS ROOM LOCATION 6 ■ SITE ID: 344199 g , _ m 732,0 10 : 0 st e +� 229 m �^ , � " T g E1 o :, -.Y_6 -' I' �i �� I 1196 s, 2966 t I�LF p�I -- CURRENT ISSUE DATE — DUAL RUN - - FIBER RUN . NEW ACCESS PANEL AS NEEDED A■. r .6. 'k rnac Y FOUR LEVELS ". 10 ti " 'OR I l 11/19/200 I l _ 06 a - e ti• L W °1 t ,oe3 sf fg RI ffi12 - • 1653 sf� _ ° p „ 1 r '.� 9 ,_,[7 1 . 1 . 4 ■ 1� aj 1060 sr _ _ an; • ■ a - ' r-6 n X75 ten g • SSUED FOR 22 . ■ j 923 s1 _JE'a p m� I I ,I. I b IL9� m 1 13'21 RE it " i. . I C ° Ifs r I CONSTRUCTION 1 i i 2-4 -1a N ORDSTROM THREE LEVELS ,n'2r,n I�.i ■ ■ ■ ��� -, 1-1 -, . • 100 _ _ '-'- r i _ $ t ry — ©. - , - 6 1 k ' - "" m le es • ■ , n d I —, J , 3s • • r;� 7 ft REV.CDATE:= ISSUED FOR Y Ntq t CI 4-0- i�t530 e J C •$ L I - 0 06/19/2007 PRELIMINARY ACS � �(�'� _ ._ . n'_T . _ .. .a _.. - - ]. ? - ir ' a o. oi9 12 y Mn55r cf 4 - , $ C1s �r ,32±4 -.- _ - — ">_. _. •32.3232 'E ® (ST51 _, - - ." _ _ ` 1'a - 17 - Z - gsg -1 -- - l �L - � 1 06/21/2007 OWNER APPROVAL ACS + -l.�e s �� ! ^ ti =^ =� - - ':° J I �s gs ww 4-1- 1 ,uc , I_ 0 4 - 3 - 1 ra 14' -� 5 iC27 1 4 - 0 2 909 I_8 [ u� s, vo]° L SOe - F 4-0 1 . -72..--c mf ,m °s_ 5a>fJ 'emu '_ -inE — _ 7^ 2 09/10/2007 PRELIMINARY ACS 9 c K C 00 h 1] 9 ' C -�. �O I9?t 5j32j 1 ( 0 - L*.3�) y s k FIBER IN CONDUI' s C 4 X BUILD' PROVI■ BY OTH: T - G, ED RS f w , i w (__) ^ l�jl I b _ , 1+ ° �re i Sze_ ° ^ a° (� n • I� N t -" Q - l'- - • 929 JCPenney ids _ . '- _ v r - o- ,_ s — m ",- 'r n -' °' • r r 3 09/26/2007 OWNER APPROVAL ACS • e 3 • • � 1 _ r 6 6 '1 -1 g © I]5B sf � m e3 636 ® 6 1, 1 I ry ( sx j - L m 669 i s]6 � • 1 - 4 - 1 . I a y ' (sib 3 8 i I - j Yi sf Si-7n, _ THREE LEVELS 2168,1•∎ 4 11/05/2007 CONSTRUCTION ACS o --f—/ 5 11/19/2007 CONSTRUCTION ACS d z.,_- t &SE ,, I r ■ I 956 s ,f ' el ' a 1461 s, J s� C $ 6 -2 -la 1 20A ELEC. CIRCUIT ( ) PROVIDED BY LANDLORD Tom/ I _ 650 s11�1' 1 1 ;4 I_ i Y I i, I.. 1129 1 � - 1 EG -t0' $ 974 sf • R �� .= 19]9 ^ v L • n5 s w- l I I I I,, � B2] 1 �1b • i�6sl -2 ` z4:1 sf --0-- 121 l , fw II �I651 � j ^I I CORE 9. ... �i � / �' 194., l II 2345 sr ' - � Qp j 111 I ,- W n. 694' � �_ -• • 32 . � zf �r tip N L ' N J 1 9$$T� ' - L - • 1 — IS � t• A911 1 __•__• 1 FAP - # 1 - __ °s7 s, mob J —r 9 1 � 122 I 1i Ic96 004, 1n]9 632 �+ M. p �pc. � O � • 1 iG 1 g}��y]\ 2 t #2 t i I t � xt \ �* 0.`l-Ck Tr � J_4 - - - - -----"---- °t 4 �. 0 c C S ,,Et 1 ! _ —^ .._i461 .1 ' . j ! gt1Lls ,° �� 1 _ -. .a 9, ,a. r a? = _ I I MODE FIBER % c7 V t U _ m * ® J f? d_- i �� - PLANS PREPARED BY 6 -2 1461 • r r�� 11 ® . 321 s T) SINGLE FIBER w= 4 i9 q. � 1 0 _ 5 IIU _ � � 1! ' T - T ' . I _ ■ - - 11926 s `• • vu IL! i9 ^ 957 ■ • 1 �,1 �F7 (1) 7 MMoll l ® - ° e , L�,.� ^ II $ p ,?R ly , 650 : R�: -1102] sf A �. 0 a ] ` ] n 1."+ a m G:. ] I ..,c ,Y1'i'(a•11cu• 1331 t^ A'1'lcl L�*U � c q W 2�a- H 3204 9, . I. p I�1 t'tlyr� dY 4 =05 5: ~ © � , 76 r 'o' � 1 - 3 - 1a ■r I i _a. _ " ' -.19 d. A' _ 11 `. (� OC OS _ u .ffi� � � � 3 W �i0�1 r Fh , . • J • ��r 71 � 1 � . SEARS CORE IN THREE L ELEC. RO E (1) 20A ELEC. CIRCUIT PROVIDED BY LANDLORD - C S - 2 -3 -1 . p ,. 1 a d I ' , ' -. _ P • ]. v e-� 3 ... ' �, 0, m� � .^r & - ED ® / CODE COMPLIANCE NFPA 70 - NEC a JAN 1 20� V OTICE :. R e _ _ - r- , Bea m 8 � 1ri'"°�_ m° V g g Gj_ - , ..ONDUIT PROVI 3Y LANDLORD_ �( ^' 7�� American Tower Corporation Proprietary and Confidential ® 2007. Intended for limited use b d ts l while perlorming y work employees Tor American an Tower agenony . Not to be distributed without the express written consent of American Tower Corporation. I t s3 s � - ___ +c , n w=�a y y s � , t•,./ n1 -. � _ - ;,� j 1� 6 °; _ � , ' - a r i 698 sl -,� m _bu - f ' . �� • I • � �o r l x p •! 739 s'Ll�c - Lyiv,7 � I K`6 . - ■ s . _ 1 I 1 tl -}- J a ' 1 ' 6326 ,f • - • M qe \ /' - { V� ` • f / ' 1 { T L T 1y — {A' O 1 1 1 \.' �h b 1 X G ______,..1 a . y ,t I M �... El %.1 X ,.y - '° I 1 = 1827 + I 20 1 r 0. DRAWN BY • 1 1 • h r1. -. � � CHK —APV ° ( .JtE' ' lus s l I • [ LICENSURE I JW I RF t / � X A 9000 s <p t b \ \ \ \ y ION D `' 39 6 s 6651 V • I � BUIW'ING ■ - ( F ®. de's l ' 2 >z -.� r. DEC 2`4 2007 P PE fv11T CIENTEi —; i N Y - `-" p i 1 r I.I. ° � • ' \\ \\ 1 r a' -T..n° s' -,t' �, Th. St F ,. ,. CONDUIT PROVIDED BY LANDLORD '— .. , , pino 4, . V n •e. _ _.-- _ -_ — — - • �_ 1 84 44 0 Ic — 2 e I q c_ t._ar �c i sr_ ■: . � i <_ - -x_ _a jc — a >K� 0 6 �, �_ .1 0 9 �_ �� Tr ® M _ SHEET TITLE - _ - __•: _ _. DAS LAYOUT LOWER LEVEL PHASE 1 / • NM IE .. , • CABLE NOTES: — - BER C . COAX: HL4RP -50 Xz" AIR DIELECTRIC PLENUM RATED (CATVP), HL- SERIES - SOohm O SOUTHCENTER AWG16 COPPER: BELDEN 6202UE - PLENUM COMMERCIAL AUDIO CABLE LOWER LEVEL (2) 72 SINGLE MODE FIBER — „DI - 9rG ATC EQUIPMENT ROOM FIBER: OPTICAL FIBER NONCONDUCTIVE PLENUM �/ �� — 6- CHANNEL: ATTENUATION 0.5 dB /km 0' 25 50' 100' I �p 1 I - -- — NUMBER. REVISION— _SHEET '^_ — _ _ L. 36- CHANNEL: ATTENUATION 0.5 dB/km t p 1 5 ttt 323232- 1 - - 49 ; ;; 9a 49 -- of „ (2) 20A ELEC. CIRCUITS -- ---ddd 1 Approxmate area 1 '` A LL CABLE TO BE of ATC equipment . PLENUM RATED _ • DAS Design: Active, BriteCell Manufact Andrew ANDREW'o American Tower Provided Materials from Andrew Phase 1 Phase 2 Phase 3 Item P/N Description Quantity Quantity Quantify 1 TLDN25 BriteCell Plus- Crossband Coupler card 2 2 TPRN14 Brite Cell Plus subrackVe backplane, 110/220 VAC 2 • ROJECT INFORMATION CARRIER INFORMATION SOUTHCENTER 3 4 TPRNO4 TFLN2504/4 BriteCell Plus subrack, no supply, passive backplane BriteCell Plus- Donor Unit 1 6 CARRIER NAME PCS A/D /B PCS E/F /C CELL NB SMR 800/900 633 SOUTHCENTER MALL SEATTLE,WA 98188 SPRINT CINGULAR 5 TLCN2 BriteCell Plus 2-way combiner /splittercard 2 NEXTEL SITE ID: 344199 VERIZON A5 B 6 7 8 TLCN4 TSUN1 TFAM 80/92/19E -34 BriteCell Plus 4 - way combiner /splitter card BriteCell Plus- Rack -mount Supervision Unit BriteCell Plus- Med RU SMR800 /SMR900/PCS 4 1 8 S 8 T MOBILE C4 & F & E CURRENT ISSUE DATE 11 /19/2007 EMS 800 ADDED REMOTE UNIT 5 -3 IN FOOD COURT ISSUED FOR f CONSTRUCTION 9 TML006 SMA terminators 22 10 TRSN 12 -1 BriteCell Plus- -48 VDC Power Supply (12 remotes) 2 = DATE: — ISSUED FOR Y _REV. 0 06/19/2007 PRELIMINARY ACS 1 06/21/2007 OWNER APPROVAL ACS American Tower Provided Materials Directly from Manufacturer Phase 1 Quantity Phase 2 Quantity Phase 3 Quantity 2 09/10/2007 PRELIMINARY ACS Item Manufacturer Description WIRING INSIDE THE MALL TO BE CONCEALED WHERE POSSIBLE. OUR CABLING INSTALLATION WILL COMPLY WITH THE NEC GUIDELINES. WE WILL NOT HAVE EXPOSED CABLING IN THE PUBLIC SPACES, FRONT OF HOUSE AREA OR WHERE EXPOSED TO DAMAGE. ALL DEVICES TO BE INSTALLED IN CEILING THAT WILL BE VISIBLE SHALL MEET THE FOLLOWING CRITERIA: • FACTORY WHITE OR OFF -WHITE ARE ACCEPTABLE. • ALL VISIBLE ATTACHMENTS SHALL BE PAINTED TO MATCH THE ADJACENT SURFACE OR DEVICE. • WHENEVER POSSIBLE PLACE DEVICES IN THOUGHTFUL LOCATIONS AWAY FROM STOREFRONTS, EDGES, AND OTHER DEVICES. ANY CONDUIT THAT PENETRATES A WALL OR ROOF MOISTURE BARRIER TO BE FULLY SEALED IN ACCORDANCE WITH THE MANUFACTURES REQUIREMENTS TO MAINTAIN WARRANTIES AND INTEGRITY OF THE BUILDING SHELL. 3 09n6n007 OWNER APPROVAL ACS 1 Eaton UPS Controller - Powerware 9125 3 4 11/05/2007 CONSTRUCTION ACS 5 11/19/2007 CONSTRUCTION ACS 2 Eaton - Powerware UPS Battery - Powerware 9125 3 Eaton National Power Corporation X - Slot Relay Card with Dry contacts (Card is installed in one UPS Controller, box is marked) 3 4 Eaton - Powerware 4 - post Rack Mounting Kit for UPS 3 5 Opto Opto22 1 — PUNS PREPARED BY 6 Select Product Group Modem Shelf 1 7 N/A Initial Carrier Commissioning 1 T \N ED R lE • ED :O 1�EE 1v CODE C�MP NEC NFP A 7O Jh�tV ^ Al 1 n" City Of TuT G D loN • BUILDING 1L 1 8 Concert Telco Extension 1 Contractor Provided Materials Phase 1 Phase 2 Phase 3 © OTICE American Tower Corporation Proprietary and Confidential ® 2007. Intended for limited use by employees and agents only while performing work for American Tower. Not to be distributed without the express written consent of American Tower Corporation. Item Part Number Description Quantity Quantity Quantity 1 BKN F4D153 - 1 Attenuator shelf (Belkin) 1 2 70 "x25 "x25 - 718" cabinet with 1500 BTU air conditioner EIC Solutions, Inc: FRM- 070- 4 -SPEC3 1 3 Sercurity Package for 1500 BTU air conditioner EIC Solutions, Inc- TRP -145V 1 DRAWN BY CHK — APV A. SLAA J JMD I RF I _LICENSURE 4 CMVDR1 Panduit Vertical Cable Management 16 ,� E It� DEC 2'4 2007 err c .rr OrA rTr-r 5 CWMPHF1 Panduit Horizontal Cable Management 2 6 CELLMAX -O -25 Cellwave Omni antenna- Td-band 22 1 4 42 ADDED 2 OMNI IN FOOD COURT 7 CSI- AP/806/2.5k/7 -10 806- 2500MHz Directional Antenna & Mount 8 4 8 Anixter 80806033 Coyote Twelve -Count Splice Tray 8 4 8 =sHE r.Lt?" ' ' MATERIAL LIST SITE INFORMATION 9 FE411920 -02 Cube -IT Wall Mount Enclosure 3F1 21.5 "W x 27"D 2 10 006e88- 31131 -29 6 Strand SMF Bundle with Copper Pairs 8 4 8 11 General Electric G/E Supra Push Button Portable Lockbox or Equivalent 1 — SHEET NUMBER. REVISION, _` {/1 T ^ 5 12 Meca Electronics, Inc 2:1 Power Divider 5 1 MATERIAL LIST 2 1 SITE INFORMATION A.B. ANCHOR BOLT A.F.F. ABOVE FINISHED FLOOR A.F.G. ABOVE FINISHED GRADE ANT. ALUMINUM ALUM. ANTENNA APPRX. APPROXIMATE(LY) ARCH. ARCHITECT(URAL) AWG. AMERICAN WIRE GAUGE BCW. BARE COPPER WIRE BLDG. BUILDING CAB. CABINET CLG. CEILING COL. COLUMN CONC. CONCRETE CONN. CONNECTION(OR) CONST. CONSTRUCTION CL CENTERLINE DIA DIAMETER DIM DIMENSION DWG DRAWING(S) EA. EACH EHUB EXPANSION HUB EL. ELEVATION ELEC. ELECTRICAL ELEV. ELEVATOR E.M.T. ELECTRICAL METALLIC TUBING ENG. ENGINEER EQ. EQUAL EXP. EXPANSION EXIST. EXISTING EXT. EXTERIOR F.F. FINISH FLOOR FIN. FINISH(ED) FLR. FLOOR FT(') FOOT(FEET) GA GAUGE GI GALVANIZE(D) G.F.I. GROUND FAULT CIRCUIT INTERRUPTER GPS GLOBAL POSITIONING SYSTEM GRND. GROUND HT. HEIGHT ICGB. ISOLATED COPPER GROUND BUS INC) INCH(ES) LB.( #) POUND(S) L.F. LINEAR FEET (FOOT) MGB. MASTER GROUND BAR/BUS MAX. MAXIMUM MECH. MECHANICAL MFR. MANUFACTURER MHUB MAIN HUB MIN. MINIMUM MISC. MISCELLANEOUS NO.( #) NUMBER N.T.S. NOT TO SCALE O.C. ON CENTER OMNI OMNIDIRECTIONAL ANTENNA PCS PERSONAL COMMUNICATION SERVICES PLY. PLYWOOD P.S.F. POUNDS PER SQUARE FOOT P.S.I. POUNDS PER SQUARE INCH PWR. POWER (CABINET) QTY. QUANTITY RAD.(R) RADIUS RAU REMOTE ACCESS UNIT REF. REQ'D. RGS. SCH. SHT. SPEC. SQ. S.S. STD. STL. STRUC. TEMP. TYP. U.G. U.L. V.I.F. W W/ W.P. WT. REFERENCE REQUIRED RIGID GALVANIZED STEEL SCHEDULE SHEET SPECIFICATION(S) SQUARE STAINLESS STEEL STANDARD STEEL STRUCTURAL TEMPORARY TYPICAL UNDER GROUND UNDERWRITERS LABORATORY VERIFY IN FIELD WIDE(WIDTH) WITH WEATHERPROOF WEIGHT 1 ABBREVIATIONS DIAMETER O S SPRINKLER HEAD LOCATION 0 GROUND ROD GROUND BUS BAR • MECHANICAL GRND. CONN. • A 0 Alk 1 C; O d " h I�i �.IL.". 11: CADWELD ELECTRIC PANEL SPOT ELEVATION REVISION GRID REFERENCE DETAIL REFERENCE ELEVATION REFERENCE SECTION REFERENCE APPROXIMATE OMNI ANTENNA UNIT LOCATION APPROXIMATE DIRECTIONAL ANTENNA LOCATION APPROXIMATE BI- DIRECTIONAL ANTENNA LOCATION POWER SPLITTER CONCRETE CONCRETE BLOCK SHEETROCK STEEL EARTH COAXIAL CABLE FIBER RUN CHAIN LINK FENCE 21 LEGEND GENERAL CONSTRUCTION NOTES: 1. THE FACILITY IS AN UNOCCUPIED DIGITAL TELECOMMUNICATION FACILITY. 2. PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY, UNLESS NOTED OTHERWISE. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 3. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE AMERICAN TOWER CORPORATION (ATC) SITE REPRESENTATIVE PRIOR TO PROCEEDING WITH THE WORK. 4. THE CONTRACTOR SHALL RECEIVE, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. 5. CONTRACTOR SHALL CONTACT USA -ALERT BEFORE PROCEEDING WITH ANY EXCAVATION, SITE WORK OR CONSTRUCTION. 6. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OTHERWISE OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 7. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. THE GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING THE BEST SKILLS AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT INCLUDING CONTACT AND COORDINATION WITH THE ATC SITE REPRESENTATIVE AND WITH THE LANDLORD'S AUTHORIZED REPRESENTATIVE. 9. SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH U.L. LISTED AND FIRE CODE APPROVED MATERIALS, PER PROPERTY OWNER APPROVAL. 10. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CHAPTER 23 OF THE UBC REGARDING EARTHQUAKE PIPING, LIGHT FIXTURES, CEILING GRID, INTERIOR PARTITIONS AND MECHANICAL EQUIPMENT. ALL WORK MUST BE IN ACCORDANCE WITH LOCAL EARTHQUAKE CODES AND REGULATIONS. 11. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. 12. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, PAVING, CURBING, VEGETATION, GALVANIZED SURFACES, EXTERIOR BUILDING WALL SURFACES, EXISTING ROOF TOP SURFACE /S, ETC. AND UPON COMPLETION OF WORK REPAIR ANY DAMAGE THAT OCCURRED DURING CONSTRUCTION TO THE SATISFACTION OF THE PROPERTY OWNER. 13. KEEP GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, RUBBISH AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY. LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST OR SMUDGES OF ANY NATURE. 14. PENETRATIONS OF ROOF MEMBRANES SHALL BE PATCHED /FLASHED AND MADE WATERTIGHT USING LIKE MATERIALS IN ACCORDANCE WITH NRCA ROOFING STANDARDS AND DETAILS. CONTRACTOR SHALL USE APPROVED PROPERTY OWNER ROOFING CONTRACTOR. 15. USE ONLY RJ-45 SHIELDED CONNECTORS. CATS TO BE TERMINATED AND TESTED TO TIA/EIA 568 -A STANDARDS STANDARD CIVIL NOTES: 1. ALL SITE WORK SHALL BE AS INDICATED ON THE DRAWINGS AND STIPULATED IN THE STATEMENT OF WORK (SOW). 2. RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 3. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY THE ATC SITE REPRESENTATIVE. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR CORE DRILLING AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. 4. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND SHALL BE CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF ATC SITE REPRESENTATIVE. STANDARD STRUCTURAL STEEL NOTES: 1. ALL METAL WORK SHALL BE IN ACCORDANCE WITH THE SPECIFICATION GALVANIZED ASTM A36 UNLESS NOTED OTHERWISE. STANDARD CARRIER NOTES: 1. AMERICAN TOWER CORPORATION (ATC) WILL NOT PROVIDE ANY CONDUIT TO THE TELCO ROOM FOR ANY CARRIER. 2. CARRIER WILL FOLLOW THE PROCEDURE OUTLINED IN THE ATC BASE TRANSCEIVER STATION ROOM AND RULES DOCUMENT. THE ATC BTS ROOM AND RULES DOCUMENT PROVIDES FOR ALL CARRIERS THE SPECTRASITE IN- BUILDING ROOM SPECIFICATIONS AND CARRIER INSTALLATION PROCEDURES. 3. CARRIER WILL COMPLETE THE SPECTRASITE BUILDING DIVISION CARRIER APPLICATION (IN- BUILDING) PRIOR TO ANY IMPLEMENTATION IN THE ATC BTS ROOM. 3'GENERAL NOTES ADDITIONAL NOTES 1. SPRINKLER SHOP DRAWINGS SHALL BE SUBMITTED TO THE LOCAL FM OFFICE AND RECEIVE THEIR APPROVAL BEFORE ANY INSTALLATION CAN BEGIN. APPROVED DRAWINGS MUST BE AT THE JOB SITE DURING CONSTRUCTION. NO VALUED OR ALARMS ALLOWED IN TENANTS SPRINKLER SYSTEM. NO THIN WALL PIPE. USE LANDLORD APPROVED SPRINKLER CONTRACTOR. A ROJECT INFORMATION SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE,WA 98188 SITE ID: 344199 CURRENT ISSUE DATE. ISSUED FOR _REV.=DATE:= ISSUED FOR 11 /19/2007 CONSTRUCTION 0 2 3 4 5 06/19/2007 06/21/2007 09/10 /2007 09 /26 /2007 11/05/2007 11/19 /2007 PRELIMINARY OWNER APPROVAL PRELIMINARY OWNER APPROVAL CONSTRUCTION CONSTRUCTION ACS ACS ACS ACS ACS ACS PLANS PREPARED BY NOTICE American Tower Corporation Proprietary and Confidential © 2007. Intended for limited use by employees and agents only while performing work for American Tower. Not to be distributed without the express written consent of American Tower Corporation. DRAWN BY I A. SLAA I JMD I RF _LICENSURE REC! DEC 2`4 2007 PERMIT GENTEEL —SHEET TITLE SHEET NUMBER HK _APV BY _1 GENERAL NOTES, LEGEND AND ABBREVIATIONS REVISION_ T2 5 0 06/19/2007 PRELIMINARY ACS 1 06/21/2007 OWNER APPROVAL ACS 2 09/10/2007 PRELIMINARY ACS 3 09/26/2007 OWNER APPROVAL ACS 4 11/05/2007 CONSTRUCTION ACS 5 11/19/2007 CONSTRUCTION ACS CVIEWE u :PLANS REPAR / = = == JAN 1 1 20( C ity Of Tukuti T10TICE American Tower Corporation Proprietary and Confidential 0 2007. Intended for limited use by employees and agents only while performing work for American Tower. Not to be distributed without the express written consent of American Tower Corporation. Permit Na Plan review approval Is subject to enms and omissions. Approval of construction documents does not authorize the violation of any adopted code Of ordinance. Receipt of approved - = - Copy and .. , . Is acknowledged: B TEMPLATE VERSION 5 -15 -2007 eld Nov 11111% Date: / ' / , ,2 )aK City of Tukwila BUILDING DIVISION VICINITY MAP o DO NOT SCALE DRAWINGS CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY • THE PROJECT MANAGER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. GENERAL CONTRACTOR NOTES -401 THE PROJECT CONSISTS OF THE INSTALLATION AND OPERATION OF AN IN- BUILDING DISTRIBUTED ANTENNA SYSTEM (DAS). PROJECT DESCRIPTION PROPERTY INFORMATION OWNER: WESTFIELD CORPORATION ADDRESS 11601 WILSHIRE BLVD. 12TH FLOOR CONTACT: BARBARA FARASH PHONE: 310- 652 -6660 AREA OF CONSTRUCTION: IN- BUILDING PRESENT OCCUPANCY TYPE: RETAIL PROPOSED OCCUPANCY TYPE: CURRENT ZONING: IM ZONING APPLICATION #: A.P.N.: TELECOMMUNICATIONS FACILITY HANDICAP REQUIREMENTS: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION HANDICAPPED ACCESS NOT REQUIRED. PROJECT SUMMARY AMERICAN TOWER SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE,WA 98188 SITE ID: 344199 ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING CODES. 1. ANSI /EIA -222 -F LIFE SAFETY CODE NFPA -101 2. UNIFORM PLUMBING CODE 3. NATIONAL ELECTRICAL CODE 4. LOCAL BUILDING CODE 5. CITY /COUNTY /ST4TE ORDINANCES CODE COMPLIANCE ASSET MANAGER NAME: BARBARA FARASH ADDRESS: 8577 RUGBY DRIVE, SUITE 103 WEST HOLLYWOOD, CA 90069 PHONE: 310- 652 -6660 PROJECT MANAGER NAME: ADDRESS: RICK FOSTER 400 REGENCY FOREST DR. CARY, NC 27518 972 -442 -2946 NATIONAL DIRECTOR OF DEPLOYMENT NAME: RICK FOSTER ADDRESS: 400 REGENCY FOREST DR. CARY, NC 27518 PHONE: 972 -442 -2946 DESIGN RF- AMERICAN TOWER NAME: JOHN WHATLEY ADDRESS: i 400 REGENCY FOREST DR. CARY, NC 27518 PHONE: 919 -466 -5655 DESIGN - AMERICAN TOWER NAME: ARIE SLAA ADDRESS: 400 REGENCY FOREST DR. CARY, NC 27518 PHONE: 919 -466 -5988 PHONE: PROJECT TEAM SHEET T1 D4 5 D 8 D9 D 0 D11 D12 ) char OT w Revi a may DESCRIPTION TITLE PAGE GENERAL NOTES, LEGEND AND ABBREVIATIONS MATERIAL LIST SITE INFORMATION DAS LAYOUT LOWER LEVEL PHASE 1 DAS LAYOUT UPPER LEVEL PHASE 2 DAS LAYOUT UPPER LEVEL PHASE 3 BTS INTERFACE SYSTEM DRAWING FIBER SCHEDULE FAP #1 NOTES & ILLUSTRATION FIBER SCHEDULE FAP #2 OUTSIDE CABINET VIEWS OPTO22, CABINET, POWER DETAILS FIBER AGGREGATE POINT MOUNTING DETAILS TRUNKING DIAGRAM ACCESS PANEL DETAILS ANTENNA MOUNTING & REMOTE UNIT DETAILS ANTENNA & REMOTE UNIT WIRING EXAMPLES MODEM SHELF & TSUN ACTIVE SUBRACK CABLE DETAILS /SS xi 11.'a II Ka ran n r[w 6— 66_, : - ikwila 1 ;ions will rat/14r.; ., _ I .�uun ulldl I nclurfa 9 ula %.4 ripiii9 City of Tukwila RUILDING DIVISION SEPARATE PERM TI REQUIRED FOR: Mechanical ❑ Electrical (irPlumbin REV. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 PublL Wor4a, Building Diviainn PERMIT NI IMRER Ap SHEET INDEX 80 1 FILE CO A ROJECT INFORMATION SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE,WA 98188 SITE ID: 344199 5 CURRENT ISSUE DATE 11/19/2007 ISSUED FOR CONSTRUCTION _REV.; DATE:= ISSUED FOR _L DRAWN BY: ICENSURE A. SLAA I JMD I RF "SHEET TITLE _SHEET NUMBER. DEC 2 4 2007 PERMIT CENTEh TITLE PAGE Y T1 REVISION_ 5 06 -05 -2008 THERESA LARGUSA 6027 44 AVE SW SEATTLE WA 98136 RE: Permit No. EL07 -801 2800 SOUTHCENTER MALL TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writinx and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 07/16/2008 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. Sincerely, er Marshall Permit Technician xc: Permit File No. ELO7 -801 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: EL07 -801 DATE: 12 -24 -07 PROJECT NAME: WESTFIELD EXPANSION - PHASE 1 SITE ADDRESS: 2800 SOUTHCENTER MALL X Original Plan Submittal _ Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPART ENTS: t r 1 19 p B ing Ivision Fire Prevention ❑ Planning Division Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2-28-02 ` COORD COPY PLAN REVIEW /ROUTING SLIP Incomplete Structural Review Required APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions DUE DATE: 12 -27 -07 Not Applicable ❑ No further Review Required REVIEWER'S INITIALS: DATE: Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 01 -24 -08 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License PIONEGI932M6 Licensee Name PIONEER GROUP INC Licensee Type ELECTRICAL CONTRACTOR UBI 601858390 Ind. Ins. Account Id 98020300 Business Type CORPORATION Address 1 PO BOX 1362 Address 2 City GOLD BAR County SNOHOMISH State WA Zip 98251 Phone 3607906805 Status ACTIVE Specialty 1 TELECOMMUNICATIONS Specialty 2 UNUSED Effective Date 7/26/2007 Expiration Date 7/26/2009 Suspend Date Separation Date Parent Company NA PIERCE CORP Previous License Next License Associated License PIERCN*932M6 Business Owner Information Name Role Effective Date Expiration Date PIERCE, NATHAN A AGENT 07/26/2007 PIERCE, NATHAN A PRESIDENT 07/26/2007 PIERCE, KATHRYN S SECRETARY 07/26/2007 Look Up a Contractor, Electrir qn or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Electrical Administrator Information License Name Status PIERCN *932M6 PIERCE, NATHAN ACTIVE https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= PIONEGI932M6 01/18/2008