Loading...
HomeMy WebLinkAboutPermit EL07-808 - WESTFIELD SOUTHCENTER MALL - BANANA REPUBLICBANANA REPUBLIC 806 SOUTHCENTER MALL ELO7-808 Parcel No.: 6364200010 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 806 SOUTHCENTER MALL TUKW BANANA REPUBLIC 806 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA DERRICK PRODIGALIDAD 13648 BURBANK BL , SHEARMAN OAKS CA Contractor: Name: ASSOCIATED ELECTRIC COMPANY Address: PO BOX 280 , SNOHOMISH WA Contractor License No: ASSOCEC088NL DESCRIPTION OF WORK: COMPLETE WIRING AND LIGHTING PACKAGE FOR NEW TI Value of Electrical: $40,000.00 Type of Fire Protection: Electrical Service provided by: PUGET SOUND ENERGY The granting of this permit does constructi erfo I hereby certify that I have read and governing this work will be complied Signatur doc: EL - 4/07 ELECTRICAL PERMIT Permit Number: EL07 -808 Issue Date: 03/31/2008 Permit Expires On: 09/27/2008 Phone: Phone: 818 786 -8960 Phone: 425 741 -9110 Expiration Date: 08/13/2008 Fees Collected: $980.50 National Electrical Code Edition: 2005 Permit Center Authorized Signature: Date: ed this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. i to give authority to violate or cancel the provisions of any other state or local laws regulating authorized to sign and obtain this electrical permit. Print Name: `+ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. EL07 -808 Printed: 03 -31 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: 1: ** *ELECTRICAL * ** doc: Cond -Elec City of Tukwila 806 SOUTHCENTER MALL TUB:W BANANA REPUBLIC Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: Date: 1 ) 6Z) EL07 -808 ISSUED 12/27/2007 03/31/2008 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does no - - + e to give authority to violate or cancel the provision of any other work or local laws regulating construction or • e p ;y ance of work. EL07 -808 Printed: 03 -31 -2008 L SITE LOCATION Site Address: Tenant Name: gelp +J� h ` Property Owners Name: ell dor Mailin g Address: I I (00) UN) L6f/l //plc Name:rnt*- Lt � rd Mailing Address._ l T b l E-Mail Addres DweckGrat Company Name: Mailing Address: CITY OF TUKWIL" Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http.Wwww.ci.tukwila.wa.us `T8Q Will service be altered? ❑ Yes Type of Use: ML LC Type of work: X New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: X Puget Sound Energy ❑ Seattle City Light ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print** .7o Ceder AkI Contact Person: E-Mail Address: Contractor Registration Number. HAApplications\Forms- Applications On Lineal -2007 - Electrical Pnmit Application doc Nt ❑ Service Change ❑ Fire Alarm Electrical Permit No. Project No. King Co Assessor's Tax No.: 6034 4 Ad(6 Suite Number: ll.35-- Floor. I New Tenant: Yes ❑ .. No City CONTACT PERSON - Who do we contact when your permit is ready to be issued rob- oo� NN Dew Telephone: (For office use only) State ❑ No Adding more than 50 amps? Yes '{:741 y'1 ye/ State fol) 91D' tir 7 se6.— f� City ,/, State Zip ) . Fax +7' -f SSi • ELECTRICAL CONTRACTOR INFORMATION Zip City Day Telephone: Fax Number Expiration Date: Valuation of Project (contractor's bid price): $ 140,00 S pe of Work (please provide AP(A) . ❑ No ❑ Remodel g Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL JEW RESIDENTIAL SERVICE ❑ New single family dwellings S140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings S75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) S55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration S75.00 (no added/altered circuits) ❑ Service change with added/altered circuits S75.00 number of added circuits r; ' " • $ 10.00 ea ❑ Circuits added/altered %)1' i thqutservice c(nanige r ..,. $50.00 (up to 5 circuits) , ' ❑ Circuits added/altered without service change • $50.00 (6 or more circuits) • $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) Signature: . Print Name: P ■ 3 Q � j � � r �3rr�l � S Mailing Address 1/ �P Date Application Accepted: `A Z�I o 1 H Applications\Porms.Applicatioos On Line A-2007 Electrical Permit Application.doc bh Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $95.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals - • $75.00 Number of concessions S10.00 ea • MULTI- FAMILY AND COMMERCIAL • ,• PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no pennit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Date: 1 y Telephone: � 477` 474 t� 1► / WA ego 3 state tip Staff Initials: Date Application Expires: 611,21— I o' Page 2 of 2 1 Parcel No.: 6364200010 Permit Number: EL07 -808 Address: 806 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 12/27/2007 Applicant: BANANA REPUBLIC Issue Date: Receipt No.: R08 -00983 City of Tukwila Initials: JEM Payment Date: 03/31/2008 01:59 PM User ID: 1165 Balance: $0.00 Payee: ASSOCIATED ELECTRIC COMPANY TRANSACTION LIST: Type Method Descriptio Amount ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Payment Check 15045 796.00 RECEIPT Account Code Current Pmts 000.322.101.00.0 796.00 Total: $796.00 Payment Amount: $796.00 Of o5 03/31 '''711 TO AL 790 doc: Receipt -06 Printed: 03 -31 -2008 RECEIPT NO: R07 -02863 Payee: PERMIT PLACE, INC. Initials: JEM Payment Date: 12/27/2007 User ID: 1165 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http.• //www.ci.tukwila.wa.us SET ID: S000000928 SET NAME: Tipp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D07 -484 1,274.44 EL07 -808 184.50 M07 -292 82.49 PG07 -349 34.50 TOTAL: 1,575.93 Payment Check 7003 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT TOTAL: Total Payment: 1,575.93 TRANSACTION LIST: Type Method Description Amount 1,575.93 1,575.93 Account Code Current Pmts 000.345.832.00.0 184.50 000/345.830 1,391.43 TOTAL: 1,575.93 6533 12/27 9710 TOTAL 1575.93 Project: _ f� 414 14C1 Type of Inspection: 700 iWC( Address: [. Date Called: Special Instructions: Date Wanted: '7/07 a.m. Requester: Phone No: 6 07 -W S • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: O X. — S Inspector: of4A/ Date: 01 Q0 f El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: riii∎4114111:_,c4 Project6 j _ r4 k Type of Inspection: 7003 Addressv ti Date Called: Special Instructions: Date Wanted: / btu a. .m. Requester: Phone No: f / INSPECTION RECORD Retain a copy with permit INSP CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION $- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 zi Approved per applicable codes. (Inspector: 61,67 Corrections required prior to approval. COMMENTS: _ Gavg - t54‘rcS -ra e c� 1 &fIc—'t (Date: p� i �l rc�s0 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: P t j4c i Type of Inspection: 707)5 AcOs: .W7c-1-.4/7-0111414--D Called: Special Instructions: Date Wanted: .S/ 7 p.m. Requester: Phone No: q Retain a copy with permit 16- ■?. INSPECTION RECORD PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 42- 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 (206)43 1 -3670 INSPECTION NO. I% proved per applicable codes. 0 Corrections required prior to approval. 4 A comMENT: 4 , i eari-Xani/dP I Date: b7/ 1 0 . El $58.00 REINSPECTION FEE REQUIRL. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Pr ject: 4/1/4 OM'at /C Type of Inspection: A q A Z ‘ Ail /VW din Date Called: Special Instructions: Date Wanted: , 72-- a.m .. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 OMMENTS: oiL- cik_ftlit1G ,c4if< 07Z - ()Aca cfil.-44166 Alcr&latf5 proved per applicable codes. Corrections required prior to approval. insPec 6/79 Date:4 0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: !Date: 3 Project: tiMA IA A /AM/ C' Type of Inspection: 7 cipi Addres5: go6 —Y0 Raeg4 A4 rgi Date Called: V Special Instructions: _., Date Wanted: 9 7 p.m. Requester: Phone No: 2-- INSPECTION RECORD Retain a copy with permit 7" INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 (206)431-3670 -A roved per applicable codes. OMMENTS: /04 01 - c-0'6'r P4 c)/c- tO4 6 sral Corrections required prior to approval. iehrM11/9//6/1 Insp r: Date: ' / o sr ID $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Pro ect: /140 'mat/ c. Type of Inspection: 7 7003 Address: gob S flte.f Att. Date Called: Special Instructions: Date Wanted: 1/U Requester: Phone No: i 407- 8 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwita, WA 98188 (206)43 1 -3670 Ap proved per applicable codes. 0 Corrections required prior to approval. COMMENTS: c4V f- /or- gtr_c 7 OM r -- A/W 77 u4/644 5246 r :/-4- Ca-riAie//6/-i (Date: W/0 /0 r ID $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed E6 - TRACK LIGHTING 137 50.0 6850.0 Applicant Phone: 512 - 744 -4400 R2 - cons FLUOR DOWN 23 28.0 644.0 • Plans Included R2 -1 - Des FLUOR DOWN 10 32.0 320.0 0 Systems Analyss spaces clearly on Z7 - CABINET LIGHTING 18 20.0 360.0 • No changes are being made to the lighting Z5 - WALL WASHERS 6 35.0 210.0 F9 -4 - CABINET LINEAR FLOOR 6 28.0 168.0 F9RD -4 - MIRROR LIGHTING 12 28.0 336.0 G1W -4 - 4' STRIP LIGHTING 1 32.0 32.0 G1W -8 - 8' STRIP LIGHTING 6 62.0 372.0 P10 - SALES PENDANT 4 54.0 216.0 F5 - OFFICE LIGHTING 1 62.0 62.0 P2 - CASHWRAP PENDANT 2 60.0 120.0 Project Info Project Address Scuthconter Date 12/14/2007 633 Southcenter Parkway For Building Depa ct REVIEW CODE CO NFPA i JAN 1 Tukwila, WA Applicant Name: Attila Horvath Applicant Address: 6615 Vaught Ranch Rd, Austin, TX 78730 Applicant Phone: 512 - 744 -4400 Project Description 1.50 2743.0 • New Building • Addition '4 Alteration • Plans Included Refer to WSEC Section 1513 for controls and commissioning requirement. • Compliance Option 0 Prescriptive • Lighting Power Allowance (See Qualification Checklist (over). Indicate Prescriptive & LPA 0 Systems Analyss spaces clearly on t ^ Alteration Exceptions (check appropriate box - sec. 1132.3) • No changes are being made to the lighting • Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) Occupancy Description Allowed Watts per f1 Area in ft Allowed x Area RETAIL STORE 1.50 3719.0 5578.5 SALES AREA ALLOWANCE 1.50 2743.0 4114.5 Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washineton State Nonresidential Ene • Code Com•liance Form Maximum Allowed Lighting Wattage " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Proposed Watts may not exceed Total Allowed Watts for Interior Revised July 2007 Total Allowed Watt l 9693.0 Total Proposed Watt s) 9690.0 72008 Notes: 1. For proposed Fixture Description, Indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. RECEIVED CITY OF TUKWILA 'DEC 2 7 20011 FILE COPY PERMIT CEd I ID J ED FOR MPLIANCE 0 - NEC DIVISION Use' LPA (W /sf) Use' LPA (W /sf) Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations 1.0 Cafeterias, fast food establishments restaurants/bars 1.3 Post office 1.1 Dormitory 1.0 Retail retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia ° , assembly spaces 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel/motel 1.0 Warehouses ", storage areas 0.5 Hotel banquet/conference/exhibition hall' 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified " DWY" shDIP1-1-1Milfil DnGRW-r DSSRULD categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers 0 Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly Indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) • Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballas 3. LED lights. 2006 Washin•ton State Nonresidential Ene Code Corn •liance Form Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 TABLE 15 -1 Unit Lichtina Power Allowance (LPA Footnotes for Table 15 -1 1) In cases In which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the r nit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the r nit Light Power Allowance for assembly. 5) Watts per square foot of room may be Increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 15011 with full height partitions, a r nit Lighting Power Allowance of 1.10 w /ft may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft 10) Display window illumination Installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three- quarter - height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed Into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power Is allowed only If the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the Interior r nit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Southcanter I Date 12/14/2007 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements In the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) I Code Section Component Information Requirec I Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations yes 1513.2 Area controls Maximum limit per switch n. a. 1513.3 Daylight zone control Schedule with type and features, Indicate locations vertical glazing Indicate vertical glazing on plans overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location yes (a) timer w/backup Indicate location yes (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability"; Indicate size of zone on plans yes 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1614) yes 1514 'Max. watts 'Indicate watts for each exit sign I LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture type lamps, ballasts, watts per fixture yes 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1611) n. a. I 1511 I Elec motor efficiencyJMECH -MOT or Equipment Schedule with hp, rpm, efficiency I TRANSFORMERS (Section 1540) n.a. I 1540 'Transformers 'indicate size and efficiency I I 2006 Washington State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft 1613.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with Individual controls, or daylight- or occupant- sensing automatic controls, which control the lights Independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either. a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall - mounted, manual switch capable of tuming off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft or 5% of the building footprint for footprints over 100,000 ft whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1614 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4-2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP -1- 2002). ACTIVITY NUMBER: EL07 - 808 DATE: 02 -19 -08 PROJECT NAME: BANANA REPUBLIC SITE ADDRESS: 806 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 Vlermit Issued DEPARTMENTS: _ B g'D�i "vision LE Comments: Documentstrouting slip.doc 2 -28 -02 PLAN REVIEW /ROUTING SLIP ..ERMIT COORD COPY Fire Prevention Planning Division Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1' Incomplete ❑ TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: n n DUE DATE: 02-26-08 Not Applicable E Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 03-5-08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: EL07 - 808 DATE: 12 -27 -07 PROJECT NAME: BANANA REPUBLIC SITE ADDRESS: 806 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: IV 1�i� �0. DTv Buirding ision Public Works ❑ � - ' PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete [El Comments: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2-28-02 Incomplete ❑ Planning Division ❑ Permit Coordinator n n DUE DATE: 01-03-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required El No further Review Required DATE: DUE DATE: 01 -31-08 Approved n Approved with Conditions VI Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: C Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Summary of Revision: ( y /Wm cAl�t=� Oros 'MY-Ot o t krty 3 MA u S,ftru . AltUfic 02_A kZi ' -`, o cc Wt.oc, =0 -, A-o0 tiv,10 ti' OF (k. - Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: - Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: PROJECT NAME: SITE ADDRESS: SC, mirtrL REVISION LOG PERMIT NO: ORIGINAL ISSUE DATE: ` Kt IA (please print) (please. print) (please print) (please print) (please print) Contact Person: City of Tukwila \applications \forms - applications on line\revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Date: feSPALARY (21 2 0 0 i 5 Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # CEI. Revision # .1. after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Sheet Number(s): ( 40 S S+ Ce 1 a 4P to "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on Steven M. Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. poi 104 X1.0 -212 fu+ - X0 I 1101 Project Name: Banana RePub1lc 2191 cbufhaerder kt411 ProjectAddress:4200 SHyrtler TgiwwiLa,wlte cm's? PeovAGFAAVArrs7 Phone Number: S€ • .IS(o . ert (90 t Summary of Revision: SALES AREA = originq I (4) *loin sttleC areas urned into (3) main ra lee a S - e TOWZOOLA : man a gets itficf to oval oddifon of go- back closet License Information License ASSOCEC088NL Licensee Name ASSOCIATED ELECTRIC COMPANY Licensee Type ELECTRICAL CONTRACTOR UBI 601371784 Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 280 Address 2 City SNOHOMISH County SNOHOMISH State WA Zip 98291 Phone 4257419110 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/13/1992 Expiration Date 8/13/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License JOHNSD*970KH Business Owner Information Name Role Effective Date Expiration Date JOHNSON, DIRK A 01/01/1980 JOHNSON, DEBORAH A 01/01/1980 ANDERSON, MARK L 01/01/1980 JOHNSON, DIRK A AGENT 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 "d Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Master Electrician Information License Name Status JOHNSD* 970KH JOHNSON, DIRK A ACTIVE https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= ASSOCEC088NL 03/31/2008 RESPONSIBILITY MATRIX LEGEND DRAWING SCHEDULE STOREFRONT EXTRUSION 0 GC FACTORY FINISHED EO -0 ELECTRICAL NOTES AND LEGEND 2005 NATIONAL ELECTRIC CODE W/ WASHINGTON AMENDMENTS EO -1 ENERGY CODE COMPLIANCE SHEETS L = LANDLORD 0 = OWNER (GAP INC,) RIRNISH® BY POWER PLAN I COMM 'S HVAC POWER PLAN I PARTIAL LIGHTING PLAN E2 -1 PARTIAL LIGHTING PLAN GC= GENERAL CONTRACTOR EMERGENCY LIGHTING PHOTOMETRIC PLAN E3--0 INSTALLED BY E3 -1 PANEL SCHEDULES RESPONSIBILITY MATRIX E3 -2 MAIN OVERCURRENT DEVICE AT LANDLORD'S SERVICE POINT L L LIGHT FIXTURE DETAILS METER AT LANDLORD'S SERVICE POINT L L C/T'S AT LANDLORD'S SERVICE POINT L L E4-2 C/T CABINET AT LANDLORD'S SERVICE POINT L L EAS DETAILS SERVICE ENTRANCE CONDUIT(S) TO LEASE SPACE L L LIGHTING FIXTURES AND LAMPS 0 GC 2 MUSIC SYSTEM /SPEAKERS /CABINET 0 0 1, 2 MUSIC SYSTEM WIRING 0 0 1, 2. 3 REMARKS: 1. ALL FINAL EQUIPMENT WIRING AND EQUIPMENT INSTALLATION BY OTHERS 2. GENERAL CONTRACTOR TO COORDINATE SCHEDULE AND DELIVERY WITH SUPPLIER. STANDARD SHIPPING PROVIDED BY GAP INC. ANY EXPEDITED SHIPPING COSTS ARE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 3. ROUGH —IN BY GC NOTE: 1. THE RESPONSIBILITY MATRIX ONLY DELINEATES ITEMS SUPPLIED AND /OR INSTALLED BY OWNER AND /OR LANDLORD. ANY WORK BY CONSTRUCTION DOCUMENTS NOT DEFINED AS RESPONSIBILITY OF OWNER OR LANDLORD IS SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR. SEE BID CLARIFICATION LETTER FOR ANY VARIATION BY SCOPE OF WORK RESPONSIBILITY. 2 . GENERAL CONTRACTOR IS RESPONSIBLE FOR THE UNLOADING OF ANY OWNER SUPPLIED CONSTRUCTION ITEMS. APPLICABLE CODES HAVING JURISDICTION OVER THIS PROJECT DRAWING SCHEDULE 2006 INTERNATIONAL BUILDING CODE W/ WASHINGTON AMENDMENTS NUMBER TITLE PLUMBING CODE EO -0 ELECTRICAL NOTES AND LEGEND 2005 NATIONAL ELECTRIC CODE W/ WASHINGTON AMENDMENTS EO -1 ENERGY CODE COMPLIANCE SHEETS ENERGY CODE E1 -0 POWER PLAN E1 -1 HVAC POWER PLAN E2 -0 PARTIAL LIGHTING PLAN E2 -1 PARTIAL LIGHTING PLAN E2 -2 EMERGENCY LIGHTING PHOTOMETRIC PLAN E3--0 POWER RISER AND SCHEDULES E3 -1 PANEL SCHEDULES E3 -2 LIGHT FIXTURE SCHEDULE E3 -3 LIGHT FIXTURE DETAILS E4 —O ELECTRICAL DETAILS E4--1 ELECTRICAL DETAILS E4-2 CASHWRAP DETAILS E4 -3 EAS DETAILS FA1 -0 FIRE ALARM PLAN LP1 -0 SECURITY ALARM PLAN E5 -0 ELECTRICAL SPECIFICATIONS f E5 -1 ELECTRICAL SPECIFICATIONS APPLICABLE CODES HAVING JURISDICTION OVER THIS PROJECT BUILDING CODE 2006 INTERNATIONAL BUILDING CODE W/ WASHINGTON AMENDMENTS MECHANICAL CODE 2006 INTERNATIONAL MECHANICAL CODE W/ WASHINGTON AMENDMENTS PLUMBING CODE 2006 UNIFORM PLUMBING CODE W/ WASHINGTON AMENDMENTS ELECTRICAL CODE 2005 NATIONAL ELECTRIC CODE W/ WASHINGTON AMENDMENTS FIRE & LIFE SAFETY CODE 2006 INTERNATIONAL FIRE CODE W/ WASHINGTON AMENDMENTS ENERGY CODE 2006 WASHINGTON NONRESIDENTIAL ENERGY CODE ELECTRICAL EQUIPMENT SUBMITTAL REQUIREMENTS OPTION 1: PROCURE FROM LOEB ELECTRIC THERE ARE NO SUBMITTAL REQUIREMENTS IF ELECTRICAL GEAR EQUIPMENT IS PROCURED THROUGH LOEB ELECTRIC. CONTACT LOEB ELECTRIC FOR PROCUREMENT PROCEDURES. ELECTRICAL GEAR CONSISTS OF BUT IS NOT LIMITED TO THE FOLLOWING ITEMS LISTED BELOW: • ELECTRICAL PANEL(S) • STEP —DOWN TRANSFORMER WITH GRD. LUG KIT AND MOUNTING ACCESSORIES (AS REQUIRED) • DISCONNECT SWITCH(ES) AND GROUND LUG KIT • MANUAL MOTOR STARTER(S) • MOTOR STARTER(S) • PHOTOCELL • LIGHTING CONTROL SWITCH AND COVER • LIGHTING RELAY(S) AND CONTACTOR(S) • CONTACTOR ENCLOSURE(S) • BYPASS BUTTON • LIGHTING CONTROL TIMECLOCKS • MANUAL MOTOR STARTER(S) WITH HOA SWITCH • AC TOGGLE SWITCHES • SPECIAL ENGRAVED LABELING OPTION 2: PROCURE FROM OTHER SOURCE 1. ELECTRICAL SUBMITTAL PROCESS 1.1. GENERAL CONTRACTOR, (G.C.), MUST PROVIDE ELECTRICAL GEAR EQUIPMENT SUBMITTALS TO GAP INC. CONSTRUCTION PROJECT MANAGER, (CPM), WITHIN 10 BUSINESS DAYS AFTER BID AWARD. G.C. SHALL NOT PROCURE ANY ELECTRICAL EQUIPMENT PRIOR TO GAP INC. APPROVAL OF ALL SUBMITTALS. ELECTRICAL GEAR CONSISTS OF BUT IS NOT LIMITED TO THE FOLLOWING ITEMS LISTED BELOW: • ELECTRICAL PANEL(S) • STEP —DOWN TRANSFORMER WITH GRD. LUG KIT AND MOUNTING ACCESSORIES (AS REQUIRED) • DISCONNECT SWITCH(ES) AND GROUND LUG KIT • MANUAL MOTOR STARTER(S) • MOTOR STARTER(S) • PHOTOCELL • LIGHTING CONTROL SWITCH AND COVER • UGHTING RELAY(S) AND CONTACTOR(S) • CONTACTOR ENCLOSURE(S) • BYPASS BUTTON • UGHTING CONTROL TIMECLOCKS • MANUAL MOTOR STARTER(S) WITH HOA SWITCH • AC TOGGLE SWITCHES • SPECIAL ENGRAVED LABELING 1.2 TIMELINES 1.2.1 UPON RECEIVING SUBMITTALS, GAP INC. WILL HAVE 5 BUSINESS DAYS TO REVIEW AND RESPOND TO SUBMITTAL IF ITEMS REQUIRE REVISION, G.C. WILL HAVE 3 BUSINESS DAYS TO RESPOND WITH CORRECTION. THIS PROCESS WILL REPEAT UNTIL SUBMITTAL IS APPROVED. 2. ELECTRICAL DESIGN SUBMITTALS CONTENT 2.1. SUBMITTALS TO INCLUDE AND BUT NOT BE LIMITED TO, THE INFORMATION LISTED BELOW: 2.1.1. NUMBER OF COPIES --- SUBMIT TWO COPIES OF EACH SUBMITTAL 2.1.2. SUBMITTAL SHALL BE PRESENTED WITH THE FOLLOWING: COVER PAGE, INDEX AND INDEX TABS. 2.1.3. IF INFORMATION MUST BE SPECIALLY PREPARED- FOR SUBMITTAL BECAUSE STANDARD PRINTED DATA ARE NOT SUITABLE FOR USE, SUBMIT AS SHOP DRAWINGS, NOT AS PRODUCT DATA. 2.1.4. ALL EQUIPMENT SUBMITTALS SHALL PROVIDE THE FOLLOWING; 2.1.4.1.1 MANUFACTURER PRODUCT CUTS SHEETS — IDENTIFYING SELECTED PRODUCT 2.1.4.1.2. MANUFACTURER PART NUMBERS 2.1.4.1.3. MANUFACTURER PRODUCT INFORMATION — OUTLINING DESCRIPTION 2.1.5. ELECTRICAL PANEL: GENERAL ELECTRIC, (G.E.), WITH NO SUBSTITUTES ACCEPTED. PROVIDE THE FOLLOWING INFORMATION: 2.1.5.1. G.E. MANUFACTURER BILL OF MATERIAL LIST, BOM. 2.1.5.2. GE BOM PANEL CUT SHEETS (PANEL DRAWING LAYOUT GENERATED BY SPEEDI —WIN) LOEB ELECTRIC CONTACT INFORMATION STEVE NGUYEN 915 WILLIAMS AVENUE COLUMBUS, OHIO 43212 PHONE: 877 - 436 -5632 EXT. 4938 FAX: 614- 299 -6268 EMAIL: SNGUYE v LOEB— ELECTRIC.COM APPROVED P' n.7 r•7r'I7lCA7 CT� Q 1 . 7 7 . "I'rNCED, MODIFIED OR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING OTIC!AL, ALI WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND IS T.'3 :ECT TO FIELD INSPECTIONS OPTION 2 PROCURE FROM OTHER SOURCE G.C. SUBMITS ELECTRICAL GEAR SUBMITTALS TO GAP INC. CPM (WITHIN 10 BUSINESS DAYS OF BID AWARD) NO SUBMITTAL REQUIREMENT REJECT APPROVED GC PURCHASE EQUIPMENT GAP INC. CPM REVIEWS SUBMITTAL (WITH IN 5 BUSINESS DAYS) GC REPLIES TO COMPLY WITH COMMENTS (WITHIN 3 BUSINESS DAYS) REJECT OR APPROVED GAP INC. CPM EMAILS APPROVAL NOTICE ELECTRICAL SUBMITTAL PROCESS NOT TO SCALE 100 V 0 V 2 IEI PS IF CFI 9 p SF P $3 $T $D BB LID 0 EH 0 EH r Ibll p FACP I ANNUN P D 0A AFF EAS EBBH EC EM EWC IC NL WP (x) ELECTRICAL SYMBOLS TELEPHONE OUTLET TELEPHONE OUTLET, FLOOR MOUNTED TELEPHONE OUTLET, CEILING MOUNTED DATA OUTLET DATA OUTLET, FLOOR MOUNTED DATA OUTLET, CEILING MOUNTED PHONE /DATA OUTLET , FLOOR MOUNTED PHONE /DATA OUTLET, CEILING MOUNTED PHONE /DATA OUTLET DUPLEX RECEPTACLE CEILING MOUNTED RECEPTACLE DUPLEX RECEPTACLE, FLOOR MOUNTED POWERSTRUT MOUNTED RECEPTACLE QUADRUPLEX RECEPTACLE DUPLEX RECEPTACLE WITH GROUND FAULT CIRCUIT DUPLEX, WHITE RECEPTACLE AND COVERPLATE DUPLEX, WHITE RECEPTACLE AND STAINLESS STEEL DUPLEX RECEPTACLE, STOREFRONT SINGLE RECEPTACLE QUADRUPLEX RECEPTACLE WITH ISOLATED GROUND DUPLEX RECEPTACLE WITH ISOLATED GROUND JUNCTION BOX SWITCH, 1 —POLE, WALL MOUNT AT 44" AFF UON SWITCH, 3 —WAY, WALL MOUNT AT 44" AFF UON MOTOR RATED SWITCH WITH THERMAL OVERLOAD PROTECTION DIMMER SWITCH MOTION SENSOR BYPASS BUTTON REMOTE BALLAST RELAY NON —FUSED DISCONNECT SWITCH FUSED DISCONNECT SWITCH MAGNETIC STARTER ELECTRICAL PANELBOARD (SHOWN TO DRY TYPE TRANSFORMER PUSH BUTTON FOR BELL OR BUZZE DOOR BUZZER BUZZER OR BELL ADA PUSHBUTTON INTERCOM CALL BUTTON ADT CONTROL PANEL SPEAKER VOLUME CONTROL SPEAKER BASS MODULE MOUNTED ABOVE CEILING ACCESS PANEL. SEE ARCHITECTURAL DRAWINGS. HOMERUN CIRCUIT POWERSTRUT SUSPENDED FROM STRUCTURE UNISTRUT FIRE ALARM CONTROL PANEL FACP REMOTE ANNUNCIATOR PHOTO CELL MANUAL PULL STATION CEILING MOUNTED SMOKE DETECTOR DUCT MOUNTED SMOKE DETECTOR 120V POWER FROM RTU REC /LT CCT INTERNAL CONTACTOR CONTROL RELAY TAMPER SWITCH WATER FLOW SWITCH HORN WITH STROBE LIGHT WALL MOUNTED STROBE WALL MOUNTED © 80" AFF HORN WALL MOUNTED © 80" A.F.F. STROBE LIGHT CEILING MOUNTED. HVAC TEMPERATURE SENSOR HVAC THERMOSTAT ELECTRICALLY POWERED EQUIPMENT IF REQUIRED ABOVE FINISH FLOOR ELECTRONIC ARTICLE SURVEILLANCE ELECTRIC BASEBOARD HEATER ELECTRICAL CONTRACTOR EMERGENCY ELECTRIC WATER COOLER — COORDINATE RECEPTACLE LOCATION WITH PLUMBING CONTRACTOR ISOLATED GROUND NIGHT LIGHTING WEATHER PROOF X = QUANTITY OF CONDUCTORS NOTE: NOT ALL SYMBOLS NECESSARILY USED ON PLAN. INTERRUPTER COVERPLATE © 80" AFF SEPARATE PERM T REQUIRED FOR Mechanical ❑ Electrical p Plumbing ati Gas Piping City of Tukwila BUILDING DIVISIC N Date: 4. 6. 7. 10. 11. FILE COP Permit I Plan review approval t Approval of consbucil the violation of any of approved Field c Ito errors and ins. not mithodze . Receipt aged: city of Tukwila BUILDING DIVISION ELECTRICAL GENERAL NOTES THE ABBREVIATION G.C., WHEREVER IT APPEARS IN THESE ELECTRICAL DRAWING, SHALL REFER TO 'GENERAL CONTRACTOR'. 2. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. LIGHTING, RECEPTACLES AND EQUIPMENT SHALL BE CONNECTED TO EXACT PANEL AND BREAKER AS SHOWN ON PLANS. ELECTRICAL HOME RUNS SHOWN ARE SCHEMATIC AND MAY ORIGINATE FROM DIFFERENT LOCATIONS UNLESS OTHERWISE NOTED. MULTIPLE CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE ACCEPTABLE. ANY RELATED COSTS FOR MULTIPLE CONNECTIONS SHALL BE INCLUDED IN BID. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION AND QUANTITY OF LIGHTING FIXTURES AND SIGNAGE ELEMENT LOCATIONS. AIM AND ADJUST ALL TRACK FIXTURES AS DIRECTED BY GAP, INC. ALL UGHTING AND RECEPTACLE CIRCUITS UP TO 60' -0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM, CIRCUITS FROM 61' -0" THRU 100' —O" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM AND FROM 101' -0" THRU 15O' —O" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM, UNLESS OTHERWISE NOTED. IN DRYWALL CEILING AREAS, ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS PANELS AS LOCATED ON PLANS. FIELD COORDINATE WITH G.C. PRIOR TO ROUGH —IN TO AVOID ANY CONFLICTS. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT THROUGH G.C. PRIOR TO ORDERING RELATED ELECTRICAL EQUIPMENT. PLACEMENT OF ALL RECEPTACLES IN THE "SALES" AREA SHALL BE INTENTIONAL (I.E. — CENTERED ON COLUMNS, WALL FEATURES OR TIGHT TO CORNERS AND FLUSH MOUNTED AT GYP BOARD WALL ONLY). FIELD VERIFY EXACT PLACEMENT OF RECEPTACLE WITH G.C. PRIOR TO ROUGH —IN. CONTRACTOR TO VERIFY THAT ALL ITEMS ON CONTRACTOR CHECKUST ARE COMPLETED PRIOR TO MEP COMMISSIONING. CONTRACTOR WILL RECEIVE CONTRACTOR CHECKLIST IN ELECTRONIC FORM WITH BID DOCUMENTS. RECEIVED CITY OF TUK FEB 1 `? 2008 PEHMII CENTER REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. - = ri r ail .. ELECTRICAL CONTRACTOR SHALL UTILIZE LANDLORD PROVIDED FUSED DISCONNECT SWITCH LOCATED WITHIN THE TENANT SPACE, ON BACK WALL, FOR TEMPORARY ELECTRICAL — FOR CONSTRUCTION. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY TRANSFORMER AND PANEL AS REQUIRED WITHIN TENANT SPACE. Public Works, Building Division PERMFT NUMBER 07 row s FeTer" CONSULTANT INFO: MIN RE'/ISION NOJ_.. SHEET STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAIL PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/1 5/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 MIN Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSIONAL STAMP: L EXPIRES 02/20/2010 1 Firm Registration No. 2002 ARCHITECT INFO: McCall Design Group 550 Kearny Sheet Suite 710 Son Francisco CA 94108 t.4 5. 288.81 50 ( . 4 1 5. 2 8 8. 8 1 8 1 www.mccolldeslgn.com ISSUE TYPE: PERMIT /BID 12/21/07 ISSUE SCALE: NOT TO SCALE DRAWN BY: RBC / MNH JOB NO.: 207338 SHEET TITLE: ELECTRICAL NOTES AND LEGEND Location (floor/room no.) Fixture Description Number of Fixtures Watts/ Fixture 200'6 Washin• on State Nonresidential Ener• Code Com.lianoe Form, , .. Interior Lighting Summary (back) :: ; :::.::: :::::::: .:: :.: LTG ANT 2066 Washington State Nonresidential Energy Code Compyanoe Form Revised,i.dy 2097 Prescriptive Spaces Warehouses, storage areas or aircraft storage hangers Other Occupancy: a Qualification Checklist Note: If occupancy type is 'Other' and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting o Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. Fixtures: (Section 1. Fluorescent fixtures which are non- lensed with a) 1 or 2 two lamps, b) reflector 1521) or louvers, c) 5-60 wall T -1, T -2, T -4, T -5, T -8 lamps, and d) hard -wired elect tropic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic bailer 3. LED lights. TABLE 15-1 Unit Lighting Power Allowance (LPA) Use' LPA` (W!Sf) I Us& LPA (1NIsfl Automotive facility 0.9 Office buildings, officeladministraUve areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, 4 • ? ' churches) 1.0 center 12 Penitentiary and other Group I -3 Occupancies 1:0 Courthouse 12 Police and fire stations' 1.0 Cafeterias, fast Todd establishments, resteurantsaars" 1.3 Post office 1.1 Dormitory 1.0. Retail retail banking, mall, concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Croup E Occupancy only), school classrooms, daycare centers 1.2 Gtintinasia assembtv soaces' to Theater . motion picture 1.2 Health care clinic 1.0 Theater, performing arts Transportafion 1.6 1.0 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 12 Hotel /motel 1.0 Warehouses'', storage areas 0.5 Hotel banquet /conference /exhibition hali 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified laboratory' shall meet office and other appropriate cateciaries) 1.8 Parking garages 0.2 Laundries 1.2 60.0 120.0 Libraries 1.3 Plans Submitted for Common Areas Only' 1513:6,1 Manufacturinq facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1,1 Ccmmon areas, corridors, toilet facilities and washroomms elevator lobbies 0,8 •_, _, Footnotes for Table 15 -1 1) In cases in which a general use and a specific Use are listed, the speciflcaly, the Unit Power Allowance shall be determined by the comparable use specified in the table. See Section 1512 for exempt 2) The was per square foot may be increased, by two percent per otherwise by subsequent footnotes. 3) Watts per square foot of roan may be increased by two percent 4) For all other spaces, such as 'seating and c'ammon areas, use the 5) Watts per square foot of room may be increased by two percent 6) Reserved. 7) For conference rooms and offices less than - I 50fl wl"th full height 8) Reserved. 9) For indoor sport tcurrrament courts with adjacent spectator seating 2.60 W/ft 10) Display window illumination installed within 2 feet of the window, walls or at least three- quarter - height partitions (transparent or opaque). with the display are exempt. An additional 1.5 w/ft of merchandise display luminaires are exempt a) located on ceiling- mounted track or directly cn or recessed b) adjustable in both the horizontal and vertical axes (vertical of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity This additional lighting power is allowed only if the lighting is actually 11) Provided that a floor plan, indicating rack location and height, is computing the interior Unit Lighting Per Allowance, as the floor of the racks. The height allowance defined in footnote 2 apples Specific Use shall apply. in cases in which a use is not mentioned building official, This determination shall be based upon the most areas. fod of ceiling height above twenty feet, unless,specifically directed per foot of ceiling height above twelve feet. Unit Light Power Allowance for assembly, per foot or ceiling height above nine feet. partitions, a Unit Lighting Power Allowance of 1.10 w/it` may be used. over 5,000, the Unit Lighting Power Allowance for the court area is provided that the display window is separated from the retail space by and lighting for free - standing display where the lighting mores provided that they comply with al three of the following: into the ceiling itself (not on the wall). axis only is acceptable for fluorescent and other fixtures with two points discharge lamps. installed. r . . EVVED C/'►�j submitted, the square footage for a warehouse ma -�, TA ri<.d � lC � area not covered by racks plus the vertical face ar a -f e- i only to the floor area not covered by racks. N 7 - NEC MAR 2 0 2008 Location (floor/room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Tukwila, SA x 5 -• TRACK LIGHTING 126 50 -0 6300.0 Project Descriptiort a2 - cos EIVOR epee 21 28.0 588.0 0 Prescriptive ® Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). er). Indicate Prescriptive & LPA spaces clearly at plans,) 5.2 -1 - COE FLOOR DOWN 6 32.0 192.0 Maximum limit per switch Z7 - CABINET LIGHTING 16 20 -0 320.0 Daylight zone control z5 - NAL;L uasEaRs 8 35.0 280.0 Y9 - cAattET LINEAR r?LUOR 6 28.0 168.0 _... F9RD -4 - MIRROR LIGHTING 12 28.0 336.0 .... ela -4 - 4' STRIP LIGHTING 2 32.0 64.0 Girt -s - 8' S9RIR I.SGaT19tl 6 62.0 372.0 Schedule with type and features, indicate location P10 - SALES PENDANT 4 54.0 216.0 F5 - OFFICE LIGHTING J 62,0 62.0 indicate location 52 - CASHaRAP PENDANT 2 60.0 120.0 Project Info Project Address Southcenter Date 2/4/2008 SR southcentex Parkway For Building Department Use Tukwila, SA Applicant Name; Attila Horvath Applicant Address: 6615 Vaught Ranch ad, Austin, TX 7573D Applicant Phone: 512 - 4400 Project Descriptiort • New Building • Addition .e Alteration • plans Included Refer to WSEC Section 1513 for Controls and commissioning requirements, Corn lianCe Option 0 Prescriptive ® Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). er). Indicate Prescriptive & LPA spaces clearly at plans,) Alteration Exceptions (check appropriate box - sec. 1132.3) 0 No changes are being made to the lighting • Less than 60% of the fixtures new installed wattage not increased, & space use not changed Location (floor /room no.) Occupancy Description Mowed Watts per fit' Area In fi Allowed x Area Cade Section RETAIL STORE 1.50 3719.0 5578.5 LIGHTING CONTROLS (Section 1513) SALES ARa*a ALLOWANCE 1 -50 2743 -0 4114.5 yes 1513.2 Area controls Lighting :Motor arid Transformer Permit Plans Checklist LTG'CHK a , 2008 Washington State Nenresi denim] Energy Code Compliance Forms Revised Jtlly 2007 Project Address Southcenter Date 2/4/2008 The following information is necessary to check a permit application for compliance with the fighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Cade_ Applicability (yes, no, n.e.) Cade Section Component Information Requfrec Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule With type, indicate locations yes 1513.2 Area controls Maximum limit per switch n.a. 1513.3 Daylight zone control Schedule with type and features. indicate locations vertical glazing Indicate vertical glazing on plans overhead glazing Indicate overhead glazing on plans yes 1513.4 Displaytexhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location yes (a) timerw/backup indicate location yes (b) photocell. indicate location 1513.6 inter, auto shut-off Indicate location yes 1513:6,1 (a) occup, sensors Schedule with type and locations yes 1513.6.2 (b) auto. switches Schedule with type arid features (back -up, override capability); Indicate size of zone on plans yes 1513.7 Commissioning indicate requirements for lighting controls commissioning (Section 1 EXIT SIGNS Section 514) ' y 1514 Max. watts Indicate watts for each exit sign LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture type lamps, ballasts, welts per fixture yes 1532 Exterior Lighting Summary Form Completed and attached- Schedule with'ftxture types, lamps, ballasts, watts per fixture MOTORS (Section 1 ..... _ ...., .. ......._._.. ..__ .... ___ ..._. . n.a. I 1511 gee c motor efficiency MECI -I-MOT or Equipment Schedule with hp, rpm. efficiency........ TRANSFORMERS (Section 1540) n.a. 1540 I Transfohners I Ina'' cote I size and efficiency P 2006 Washin • on. State Nonresidential : Ener• Code tom • fiance Form Interior Lighting Summary .::::: LTG-INT 2009 Washington State Nonresidential gneA]y Code Compliance Pores Maximum Allowed Lighting Wattage "* From Table 15 -1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Proposed Watts may not exceed Total Allowed Watts for Interior Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture. and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information, 2. For proposed Watts/F"ctture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530_ For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual iii iinafre`waitage or length of track multiplied by 50, or as applicable, the wattage of current rmitfng devices or Of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. 7• 008 Revised July 2007 Total Allowed Watt 9693.0 Total Proposed Watts] 9018.0 2006 Washington State Nonresidential nergyCode Compliance Form If "no" is circled for any question, provide explanation: Citv Of Tukwila E Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting In Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling - height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable ref turning off all lights within the space. The controls shall be readily accessible, at the point of entry /exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations' 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automotie control shall not exceed that which is provided by 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently, Circuit breakers may not be used as the sole mea of switc. EXCE PTION ns S: 1, Indu or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 fe. 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with Individual controls, or daylight- or occupant-sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e_ north, east, south, west). Daylight zones under overhead glazirig More than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut - off Controls, Exterior. Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk-to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch, Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power fora period of at least 10 hours, EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut-Off Controls, interior. Buildings greater than 5,000 ft2 and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513,6.1. For other spaces, automatic controls may be an occupancy", sennser, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or 2006 Washin• •n State Nonresidential Ener• Code Com•IianceForm Lighting, Motor, and Transformer Permit Plans Checklist LTG-CHIC 7000 Weshtngtdn Slate Norre ident ra Fnergy Code Compllenrs Forms Revised July 2907 illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4 . Hospitals and la boratory spaces, 5. Areas In which medical or dental tasks are performed are exempt from the occupancy sensor req uirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes afterthe area has been vacated. Light fixtures controlled by occupancy seeSors'shall have a wall mounted, manual switch capable of turning off lights when the space is occupied. EXCEPTION: occupancy sensors in stairwells are allowed to have two step fighting (high -light and low - l prov htro f gh -light piti 1513.6,2 ght) Auto id t T i me con Sw l ils in th Auto mati time o n. switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut-off" feature, which turns off all loads for at feast 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back-up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride s itching d a. Is readily evice accessible ; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illurriinated is annunciated; C. Is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ftz or 59 of the building footprint for footprints over 100,000 if, whichever Is greater. 1513:7 Commissioning Requirements: For lighting controls which include daylight or occupant-sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be furtctiorrallytested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance With this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an I-P/AC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment 2, Where the motor is integral to a fisted piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 - ..TRANSFORMERS The minimum efficiency of a low voltage dry -type distribution transformer shall be the Class 1 Efficiency Levels for distribution transformers specified In Table 4-2 of the Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical t VECE! • ��/ I D Manufacturers Association (NEMA TP- 1- 2002). CITY OF T U 'WILA FEB 1 9 2008 PEH+.4IT CENTER NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.0$ CONSULTANT INFO: illlli =M Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSIONAL STAMP: Firm Registration No. 2002 ARCHITECT INFO: JOB NO.: SHEET TITLE: ENERGY CODE COMPLIANCE SHEETS SHEET NUMBER: EO -1 8997 McCall Design Group 550 Kearny Street Suite 710 Son Francisco CA 94108 1 . 4 1 5. 2 8 8. 8 1 5 0 f . 4 1 5. 2 8 8. 8 1 8 1 www.mccalldesign.com ISSUE TYPE: PERMIT /BID 12/21 /07 ISSUE SCALE: NOT TO SCALE DRAWN BY: RBC / MNH 207338 NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Sauthcenter Parkway Tukwila, WA 98188-2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 CONSULTANT INFO: O k Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSIONAL STAMP: \ \ y„ B. HO,y .- ?,, p 43998 Ge- .' • w 0, , -G /STE `. ; ' , SS,ONAL E'. I EXPIRES 02/20/2010 1 Firm Registration No. 2002 ARCHITECT INFO: McCall Design Group 550 Keamy Street Suite 710 San Francisco CA 94108 t- 4 1 5. 2 8 8. 8 1 5 0 1. 4 1 5. 2 8 8. 8 1 8 1 www.mccalldesign.com ISSUE TYPE: PERMIT /BID 12/21 /07 ISSUE SCALE: 1/8" =1' -0' DRAWN BY: RBC / MNH JOB NO.: 207338 SHEET TITLE: POWER PLAN SHEET NUMBER: E1 -0 E_;; I HAII'WAY 'r S ()CO MM EEN'S l 1 (..)0M OFFICE FIRE A PANEL B39 B25 -1 4 `ail► iii B36 ( B37 201 E4 -0 MEN'S (-„;, OIIFT ROOIM B -27 B17 B30 B26 B28 B24 F I1 TING P0 M MGR'S AREA C- 8 -0" m W W z $1Z B31--I3-35 l !I LIGHTING CONTACTORS IN ENCLOSURE WITH TIMECLOCKS MOUNTED BE k4 r r I r) SALES AREA 3 B13 B13 J 200 100 E1-0 POWER PLAN 1/8" =1'-0" SAI. E S AREA 2 r . SALES AREA 1 A PLACE "AS— BUILT" ELECTRICAL DRAWINGS IN DRAWING TUBE. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. (200) SALES AREA AND STOCKROOM RECEPTACLES SHALL BE WHITE IN COLOR WITH WHITE NYLON COVERPLATE, WITH CENTERLINE 21" AFF. RECEPTACLE SHALL BE FLUSH MOUNTED HORIZONTALLY. FIELD VERIFY EXACT LOCATION WITH G.C. PRIOR TO ROUGH —IN OF RECEPTACLE BOXES. 201) TOILET ROOM RECEPTACLES SHALL BE GFI TYPE, GRAY IN COLOR WITH WHITE NYLON COVERPLATE, WITH CENTERLINE 44 ". FIELD VERIFY WITH G.C. PRIOR TO ROUGH —IN OF RECEPTACLE BOXES. 202) STEAMER RECEPTACLE SHALL BE WHITE IN COLOR WITH WHITE NYLON COVERPLATE, WITH CENTERLINE 48" AFF AT NONE SALES AREA, AND 21 " AFF AT SALES AREA. LABEL COVERPLATE "STEAMER" WITH A 3/8" ENGRAVED LAMINATED PLATE. FIELD VERIFY EXACT LOCATION WITH G.C. PRIOR TO ROUGH IN OF RECEPTACLE BOX. STOREFRONT SHOW WINDOW RECEPTACLES SHALL BE WHITE IN COLOR WITH WHITE NYLON COVERPLATE, RECEPTACLE SHALL BE FLUSH MOUNTED HORIZONTALLY IN CEILING. FIELD VERIFY EXACT LOCATION WITH G.C. PRIOR TO ROUGH —IN OF RECEPTACLE BOXES. 204) POWER AND DATA OUTLET ABOVE COUNTER AT BACKWRAP LOCATION. INSTALL CONDUIT WITH ONE (1) PULLWIRE TO P0S SWIP CABINET. COORDINATE LOCATION WITH GC PRIOR TO ROUGH —IN. POWER CODED NOTES REAR DOOR DELIVERY BELL AND TRANSFORMER. INSTALL LOW VOLTAGE WIRING TO BELL IN STOCKROOM AND PUSHBUTTON AT REAR DOOR. REFER TO DOOR BUZZER DETAIL FOR ADDITIONAL REQUIREMENTS. 4" SQ X 1 1/2" DEEP BOX WITH SINGLE GANG 1/2" PLASTER DEVICE RING COVER, CENTER INSTALLED AT 38" A.F.F. FOR EMPLOYEE TIME CLOCK. VERIFY EXACT LOCATION WITH G.C. PRIOR TO ROUGH —IN. RUN A 3/4" EMPTY CONDUIT, WITH PULLWIRE FROM JUNCTION BOX TO MANAGER'S DESK. DUPLEX RECEPTACLE WITH CENTER INSTALLED AT 38" AFF FOR EMPLOYEE TIME CLOCK POWER AND /OR GENERAL USE. VERIFY EXACT LOCATION WITH G.C. PRIOR TO ROUGH —IN. TELEPHONE TERMINAL BOARD. CONDUIT WITH PULL WIRE FOR EAS SYSTEM. REFER TO EAS DETAIL DRAWINGS FOR FURTHER REQUIREMENTS. RECEPTACLES FOR MICROWAVE OVEN AND REFRIGERATOR (ONE DUPLEX PER APPLIANCE). RECEPTACLE SHALL BE WHITE IN COLOR WITH WHITE NYLON COVERPLATE, WITH CENTERLINE 48" AFF. FIELD VERIFY EXACT LOCATION WITH G.C. PRIOR TO ROUGH—IN OF RECEPTACLE BOXES. STOREFRONT SHOW WINDOW RECEPTACLES SHALL BE WHITE IN COLOR WITH WHITE NYLON COVERPLATE, RECEPTACLE SHALL BE FLUSH MOUNTED IN WALL 21" AFF. FIELD VERIFY EXACT LOCATION WITH G.C. PRIOR TO ROUGH —IN OF RECEPTACLE BOXES. SINGLE GANG JUNCTION BOX AT 48" AFF TO STEREO SYSTEM VOLUME CONTROL, WITH 3/4" CONDUIT AND PULL WIRE STUBBED UP TO ACCESSIBLE CEILING. FIELD VERIFY EXACT LOCATION WITH DISPLAY G.C. PRIOR TO ROUGH—IN. AREA 2 "A° ` RECESSED SINGLE GANG BOX WITH WHITE COVERPLATE FOR TELEPHONE CONNECTION, WITH CENTER LINE AT 48" AFF INSTALL CONDUIT WITH ONE (1) PULLWIRE TO POS SWIP CABINET. REFER TO CONDUIT RISER DIAGRAM. 4" X 4" X 1-1/2" J —BOX WITH COVER FOR TRAFFIC COUNTER SYSTEM. INSTALL CONDUIT BETWEEN EACH J —BOX WITH A HOMERUN BACK TO MANAGER'S OFFICE FOR EVERY GROUP OF FIVE (5) J— BOXES. SEE ARCHITECTURAL DRAWINGS FOR LOCATION. REFER TO CONDUIT RISER DIAGRAM. COORDINATE CORE DRILL /SAWCUT LOCATION FOR UNDERGROUND CONDUIT(S) WITH G.C. AND LANDLORD'S REPRESENTATIVE PRIOR TO PROCEEDING WITH ANY WORK. PATCH /SEAL FLOOR TO MATCH EXISTING FLOOR FINISH AFTER INSTALLATION OF CONDUITS. ISOLATED GROUND QUAD RECEPTACLES FOR NETWORK RACK. EAS JUNCTION BOX. SEE EAS DRAWING FOR REQUIREMENTS. VERIFY LOCATION WITH G.C. PRIOR TO ROUGH IN. 4" X 4" X 1-1/2" J —BOX WITH DUPLEX RECEPTACLE STEREO SYSTEM. INSTALL (2) 3/4" CONDUITS WITH PULL WIRE FROM J--BOX UP TO TOP PHONEBOARD. VERIFY LOCATION WITH G.C. PRIOR TO INSTALLATION. (304) LIGHTING CONTACTORS FOR LIGHTING CONTROLS IN ENCLOSURE. SEE DETAIL FOR QUANTITY. DISCONNECT SWITCH FOR ELECTRIC WATER HEATER. PROVIDE FLEXIBLE SEALTIGHT CONNECTION TO UNIT. RECEIVED CITY OF T Lii.c:-'V9LA FEB 19 2008 PERMIT CENTER F FXI i HALLWAY C[R OC ;1 MEN'S TOILET ROOM FITTING ROOM AREA OFFICE MCX'S - IL .JL JL it 1 L.JL r 1 K,I I�1 LJL I [r L. 2 SALES AREA 3 • E1 -1 / 1/8" =1 SALES AREA rE r (FPB 1) 100 HVAC POWER PLAN U ri F iK> A L _) Jri 70 OIL r � L J SALES AREA 1 • I TL j 3 DISPLAY AREA 1 EN TRY DISPLAY AREA 2 POWER CODED NOTES DUCT MOUNTED SMOKE DETECTOR. COORDINATE WITH G.C. AND MECHANICAL CONTRACTOR FOR LOCATION. J —BOX FOR THERMOSTAT /SENSOR MOUNTED AT 48" A.F.F.. INSTALL 1/2" CONDUIT WITH BUSHINGS AND PULLWIRE TO ABOVE CEILING FOR CONTROL WIRING. COORDINATE LOCATION WITH G.C. PRIOR TO ROUGH —IN. 307) JUNCTION BOX FOR POWER TO FIRE /SMOKE DAMPER. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH —IN. RECEI\ CITY OF T L'K wl.LA FEB 19 2008 PEHMIT CENTER BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 NEW STORE STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 CONSULTANT INFO: O Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744-4400 EEA Project # 2079563 PROFESSIONAL STAMP: ARCHITECT INFO: M McCall Design Group 550 Kearny Street Suite 710 San Francisco CA 94108 1. 4 1 5. 2 8 8. 8 1 5 0 f.415.288.8181 www.mccalidesign.com EXP!RES 02120/2015 Firm Registration No. 2002 ISSUE TYPE: PERMIT /BID ISSUE SHEET NUMBER: E1 -1 12/21/07 SCALE: 1/8" = 11 -0n DRAWN BY: RBC / MNH JOB NO.: 207338 SHEET TITLE: HVAC POWER PLAN L A- - l — 'I -By - -A, l NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 CONSULTANT INFO: _k Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSIONAL STAMP: y co r { : 14 9 43998 O cZ ., SS /ON AL E v_ EXPIRES 02/20/2010 1 Firm Registration No. 2002 ARCHITECT INFO: McCall Design Group 550 Kearny Street Suite 710 San Francisco CA 94108 t. 4 1 5. 2 8 8. 8 1 5 0 ?,415.288.8181 www.mccalldeslgn.com ISSUE TYPE: PERMIT /BID 12/21 /07 ISSUE SCALE: 1/4"=1 DRAWN BY: RBC / MNH JOB NO.: 207338 SHEET TITLE: PARTIAL LIGHTING PLAN SHEET NUMBER: E2 -O EM,NL © rb\ fo j B8 — B8 — B8 B8 FIXTURE TYPE P2, (TYP) 812 EM,NL B12 EM,NL 812 EM,NL FIXTU B1/ A B1/ B3 B1 83 B12 EM,NL 0 i B1/ 1 B3 61/ � < UR: TYPE B3 114B9 �ii► 11 B5 P 4 B7 B� B12 EM,NL B5/ n pi. B7 A_ 1 L . L 1L - r1 a ~1 n L A .& 100 PARTIALLIGHTING PLAN E2 -0 1/4" =1 B12 EM,NL FIXTURE R2E, (TY FIXTURE TYPE XE1, (TYP) p RH B1/ B3 B5/ B7 AREA 1 B2 L. FIXTURE TYPE F9 -4, (TYP) FIXTURE TYPE E6 D7 TRACK, (- B12 B2 ON rP) (NP) B2 B1/ B3 B5/ 87 B6 B12 0— B6 B4 FIXTURE TYPE X1, (TYP) B4 ,I t . 1 • \\ \ FIXTURE TYPE E6 ON I D7 TRACK, (TYP) B6 11 l I V\ - - - i AREA 1 FIXTURE TYPE f Z8, ( 1-'YP) H I FP 7` I FIXTURE TYPE P5, (TYP) AF) FIXTURE TYPE S10, (TYP) i 14 LIGHTING CODED NOTES INSTALL SHADED FIXTURES ON TWO CIRCUIT TRACK UPPER CIRCUIT, (CIRCUIT #2), AND NON— SHADED FIXTURES ON TWO CIRCUIT TRACK LOWER CIRCUIT, (CIRCUIT #1). INSTALL AND WIRE LIGHT FIXTURE ON TWO CIRCUIT TRACK LOWER CIRCUIT, CIRCUIT #1. J NOTE: 2006 IBC — Sec. 1006 Provide an average of one foot- candle illumination at the floor along the entire egress pathway and exit discharge RECEIVED CITY OF 9 :_ FEB 1 9 2008 PEHMJT CENTER EM,NL © rb\ fo j B8 — B8 — B8 B8 FIXTURE TYPE P2, (TYP) 812 EM,NL B12 EM,NL 812 EM,NL FIXTU B1/ A B1/ B3 B1 83 B12 EM,NL 0 i B1/ 1 B3 61/ � < UR: TYPE B3 114B9 �ii► 11 B5 P 4 B7 B� B12 EM,NL B5/ n pi. B7 A_ 1 L . L 1L - r1 a ~1 n L A .& 100 PARTIALLIGHTING PLAN E2 -0 1/4" =1 B12 EM,NL FIXTURE R2E, (TY FIXTURE TYPE XE1, (TYP) p RH B1/ B3 B5/ B7 AREA 1 B2 L. FIXTURE TYPE F9 -4, (TYP) FIXTURE TYPE E6 D7 TRACK, (- B12 B2 ON rP) (NP) B2 B1/ B3 B5/ 87 B6 B12 0— B6 B4 FIXTURE TYPE X1, (TYP) B4 ,I t . 1 • \\ \ FIXTURE TYPE E6 ON I D7 TRACK, (TYP) B6 11 l I V\ - - - i AREA 1 FIXTURE TYPE f Z8, ( 1-'YP) H I FP 7` I FIXTURE TYPE P5, (TYP) AF) FIXTURE TYPE S10, (TYP) i 14 LIGHTING CODED NOTES INSTALL SHADED FIXTURES ON TWO CIRCUIT TRACK UPPER CIRCUIT, (CIRCUIT #2), AND NON— SHADED FIXTURES ON TWO CIRCUIT TRACK LOWER CIRCUIT, (CIRCUIT #1). INSTALL AND WIRE LIGHT FIXTURE ON TWO CIRCUIT TRACK LOWER CIRCUIT, CIRCUIT #1. J NOTE: 2006 IBC — Sec. 1006 Provide an average of one foot- candle illumination at the floor along the entire egress pathway and exit discharge RECEIVED CITY OF 9 :_ FEB 1 9 2008 PEHMJT CENTER NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/1 5/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 Z CONSULTANT INFO: MINI MIN Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSIONA TAMP: F �'�4 yeti , vim O a: G] :. 0 �. 9 43998 I E �a �ti �.� G /sT�R G � a . ss /ON AL t‘ C' '' , EXPIRES 02/20/2010 Firm Registration No. 2002 ARCHITECT INFO: MCCCII Design Group 550 Kearny Street Suite 710 San Francisco CA 94108 1.415.288.8150 1.415.288.8181 www.mccalldesign.com I SSUE TYPE: PERMIT /BID 12/21 /07 ISSUE SCALE: 1/4"=V-0" DRAWN BY: RBC / MNH JOB NO.: 207338 SHEET TITLE: PARTIAL LIGHTING PLAN SHEET NUMBER: E2 -1 LS, FIXTURE TYPE R2, (TYP) FIXTURE TYPE R2E, (TYP) FIXTURE TYPE Z7, (TYP) FIXTURE TYPE Z5, (TYP) EM,NL FIXTURE TYPE F5E, (TYP) l r�� 1r L L. m /W RE . PARTIALLIGHTING PLAN 1/4" =1'-0" B10 B10 AwfovvviA B12 /1312 EM, N EM,NL B2 B1 Ely LIGHTING CODED NOTES EXHAUST FAN IN CEILING, SWITCHED WITH ROOM LIGHTS. OCCUPANCY SENSOR SWITCH FOR CONTROL OF ROOM LIGHTING. OCCUPANCY SWITCH SHALL BE A WATT STOPPER WA200. SET SWITCH FOR MAXIMUM SENSITIVITY. CONTROL AND ADJUST SWITCH TO MAINTAIN LIGHTS ON FOR 15 MINUTES AFTER LAST MOTION IS DETECTED. SWITCH SHALL BE ADJUSTED TO OVERRIDE THE LIGHT LEVEL ENERGY SAVING FEATURE. DIP SWITCH SETTING OF THE SWITCHES BENEATH THE COVER SHALL BE SET AS FOLLOWS: ON -- DIP 1,7,8 OFF - DIP 2,3,4,5,6 BYPASS BUTTON LIGHTING CONTROL SWITCH. DIP SWITCH SETTING FOR DEVICE SHALL BE SET AS FOLLOWS: ON - DIP 2,6 OFF - DIP 1,3,4,5 PROVIDE SEPARATE UNSWITCHED HOT CIRCUIT TO EMERGENCY BALLAST IN FIXTURE. od5 RECEIVE0 CITY OF TL , :\APLA FEB 19 2008 PERMIT CENTER NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 D CONSULTANT INFO: � s Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSIONAL STAMP: :' ` 9 1 / 1 .. pF WAS/../, -1.A. i~ 1. Q i 0 9 43998 i s4 ,c� 6 Q/ST E. ��, >° S /ONAL E� I EXPIRES 02/20/2010 I Firm Registration No. 2002 ARCHITECT INFO: McCall Design Group . 550 Kearny Sheet Suite 710 San Francisco CA 94108 t. 4 1 5. 2 8 8. 8 1 5 0 1.415.288.8181 www.mccalldesign.com ISSUE TYPE: PERMIT /BID 12/21 /07 ISSUE SCALE: 1/8".1 DRAWN BY: RBC / MNH JOB NO.: 207338 SHEET TITLE: EMERGENCY LIGHTING PHOTOMETRIC PLAN SHEET NUMBER: E2 -2 STATISTICS (CALCULATED AT FLOOR HEIGHT) Description Symbol Avg Max Min Max /Min SALES FLOOR + 4.6 fc 10.7 fc 0.5 fc 21.4:1 F_ X I I HAI_I. WAY IO ..; T WOMEN'S TOILET ROOM \ 22 4.6 o F i X7.2 + +2. +Pi +6.P 8� + j1.6 + + * 1 4 + 4.9 - + 5 4 + 2.8 + 5.8 4-. 7.6 + 7.0 + 5.0 + 4.5 + 5.9 + 7.: + 7.1 + 4.8 + 1.8 - - 0 0 0 0 0 0 + + + + + + + + + + + 8.1 8.8 9.3 8.7 7.6 2.9 6.0 7.9 7.6 5.14 + + + 4.7 6.2 8.1 7.7 4.9 1.j 1.0 + + + + + + + + + + + + + + IL 8.3 10.0 10.2 9.8 8.7 1.8 3.8 - - - T 5.6 5.: 4.1 3.9 2.6 1.2 0.8 1.7 TOILET ROOM ` + + + + + + + 5.3 • 6.9 8.1 8.9 9.3 9.4 9.0 + + + 5.5 7.0 82 $au _ . _ 7.6. Ff I f If G ROOM MGGR AREA OFFICE t8 .4 8.8 . 5 7 8.5 9.0 9.6 10.1 1a7_ 7 1 + 953'=9.1 7.4 1.4 76 + 7 1 1 -+ 6.1 1+ 7.3 + + + 0 + + 2.8 WiftnlA L,_ + 4.9 + 6.0 + 6.8 + 7.0 + 6.7 + 6.4 L + 6.1 + 16.1 + 6.9 + 8.1 I + 8.9 17.0 6. 7.7 7.4 4.6 t8 0.6 t8 0.4 + 6.6 0 + 7.4 :7 • + + + +c_ + + � 7.O I - 4.3 t8 0.9 1.1 3.3 4.3 8 5.6 4.6 JA .IC �fsj 1.3 + 2.0 + 3.8 + 4.7 + 4.0 + 1.4 0 + + + + 1.2 t3 1.2 + + + SALES AREA P 0 + + 6.1 6.9 2 + 7.8 0 + 8.3 4. ' SALES AREA 2 + + 3.3 4.1 + 4.6 4.6 + + 5.1 3.6 + + + + Q + 7.8 7.9 5.4 4.1 + 4.9 0 + 5.1 6.0 6.8 + + + ,.+ 3.6 4.6 -L / +4v +4.3.5 + 2.5 1.6 Q O ;ALES AREA 1 + + 4.5 4.0 3:6 + u + 1 + + + + .1 1.8 L8 1.7 1.1 + nl + + 1.7 2.9 + + 3.0 1. + 4.0 + 5.1 + 4.7 + 5.4 + 2.9 + + + + + + + -I- 6.2 7.2 6.4 6.3 6.9 8.4 6.6 + 6.6 + 6.5 7 .0 + + 6.0 3. - - M P + ?.3I 1.1 + + 3.7 t9 +1 L� 4:� + +� ± - --- -- + + 9 4.8 2.7 14 + 2 + + + + .3 2.0 2.0 2.0 1.1 CJ DISPLAY AREA 1 FNIRY DISPLAY AREA 2 ( 10 EMERGENCY LIGHTING PHOTOMETRIC PLAN E2 -2 i 1/8" =1'-0" PHOTOMETRIC GENERAL NOTES 1 UNITS ARE IN FOOT- CANDLES, MEASURED AT FLOOR LEVEL EGRESS AND EXIT ILLUMINATION TO PROVIDE NOT LESS THAN ONE FOOT- CANDLE OF LIGHT THROUGHOUT PATH OF EGRESS. EXIT SIGNS LOCATED AT REQUIRED EXITS AND AT DIRECTIONAL CHANGES ALONG PATH OF EGRESS. 2. EMERGENCY LIGHTING FIXTURES AND EXIT LIGHTING FIXTURES EQUIPPED WITH 90 MIN BACKUP BATTERY PACKS. O 1352=23 + 4.9 PHOTOMETRIC READING (4.9 FC AT FLOOR) EMERGENCY LIGHTING EXIT LIGHT PHOTOMETRIC LEGEND RECEI \ /ED CITY OF IL.v../oLA FEB 19 2008 PEHMIT CENTER EQUIPMENT WIRING SCHEDULE SYM. ITEM VOLTAGE HP KW F.L.A. FEEDERS TYPE OF CONN. NEMA RATING DISC. SW. BUSS FUSES REMARKS WIRE COND. 1 INCOMING SERVICE / PANEL A 480V, 3PH - -- 45.6 - -- 4 #3/0, 1 #4 GND 1 0 2" M.C.B. 1 - -- - -- 1.25 2 XFMR 480V, 3PH - -- - -- 54 3 #4, 1 # GND 1 0 1 -1/4" DIRECT 1 - -- - -- 15.25 FT 3 PANEL B 208V, 3PH - -- 24.7 - -- 4 #1, 1 #6 GND, 1 #8 IG 1 0 2" M.C.B. 1 - -- - -- 6.8 4 XFMR GROUND 6.8 - -- - -- - -- 1 #2 GND. 1 0 3/4" DIRECT 1 - -- - -- SEE NOTE #1 BELOW 5 FPB -1 480V, 3PH 3/4 5.5 - -- 4 #12, 1 #12 GND 1 0 3/4" DISC. SWITCH 1 30 - -- 18.4 * 6 FPB -2 480V, 3PH (2) 3/4 8.0 - -- 4 #10, 1 #10 GND 1 0 3/4" DISC. SWITCH 1 30 - -- AIR CONDITIONING 7 FPB -3 277V, 1 PH 1/4 0.5 ---- 2 #12, 1 #12 GND 1 0 3/4" TOGGLE SWITCH 1 20 - -- 8 EWH 120V, 1PH - -- 1.5 - -- 2 #12, 1 #12 GND 1 o 3/4" DISC. SWITCH 1 30 - -- u A NOTES: 1. GROUND TO BUILDING STEEL IN GENERAL VICINITY OF TRANSFORMER ELECTRICAL LOAD SUMMARY DESCRIPTION ACTUAL CONNECTED KW/KVA DEMAND FACTOR ACTUAL DEMAND KW/KVA N.E.C. CONNECTED KW/KVA N.E.C. DEMAND FACTOR N.E.C. DEMAND KW/KVA TRACK 5.64 1.25 7.04 126 FT 150W / 2FT 11.8 LIGHTING 9.45 KW x 1.25 GENERAL 4.42 1.25 5.53 4.42 1.25 5.53 LIGHTING SHOW WINDOW -*** 1.25 _t** 15.25 FT 200W / LF 2.15 **** LIGHTING ALLOW. 3.05 KW x 1.25 GEN. PURPOSE 6.8 1.0 < 10KW 6.8 6.8 1.0 < 10KW 6.8 RECEPTACLE 0.5 > 10KW 0.5 > 10KW MOTOR(S) 0 1.0 + 25% 0 0 1.0 + 25% 0 LARGEST LARGEST FIXED ELECTRIC 18.4 * 1.0 18.4 * 18.4 * 1.0 18.4 SPACE HTG. AIR CONDITIONING 0* 1.0 + 25% 0* 0* 1.0 + 25% 0* EQUIPMENT LARGEST ** LARGEST ** ELECTRIC 4.16 1.0 4.16 4.16 1.0 4.16 WATER HEATER MISCELLANEOUS 6.32 1.0 6.32 6.32 1.0 6.32 LOADS TOTAL 45.8 48.3 52.6 55.2 NOTES: * USE GREATER VALUE OF THE TWO CATEGORIES WHERE LOADS ARE NON - CONCURRENT. ** 125% OF LARGEST COMPRESSOR MOTOR IN SYSTEM. APPLIES TO ONLY ONE UNIT. *** ACTUAL SHOW WINDOW LIGHTING IS INCLUDED IN TRACK AND GENERAL LIGHTING SECTIONS. **** 200 VA /FT REQUIREMENT LESS ALLOWANCE (150W/2FT) FOR TRACK LIGHTING INSTALLED IN SHOW WINDOWS. MINIMUM FEEDER = 55 INA x 1000 = 66.4 A. AMPACITY 480 x 1.73 ELECTRICAL SERVICE AMPACITY = 200 A. 0 480V, 3 PH ELECTRICAL CONTRACTOR TO VERIFY AND REUSE METER, METER SOCKET, C.T.'S, AND 200 AMP 3 POLE CIRCUIT BREAKER. VERIFY EXACT REQUIREMENTS WITH LANDLORD PRIOR TO BID. LANDLORD VERIFY IN FIELD LEASE UNE TENANT'S SPACE TENANT'S ELECTRICAL CONTRACTOR SHALL FURNISH AN IDENTIFICATION NAMEPLATE ON TENANT'S MAIN DISCONNECT SWITCH IN LANDLORD'S SWITCHBOARD. NAMEPLATES SHALL BE ONE- EIGHTH INCH (1/8") THICK PLASTIC, BLACK ON WHITE AND ETCHED LETTERS. THE MINIMUM SIZE SHALL BE ONE INCH (1") WITH ONLY THE TENANT'S SPACE NUMBER ENGRAVED ON SUCH, PERMANENTLY AFFIXED. I ISC = 24,638A LANDLORD'S SWITCH GEAR -HL 10 "- NETWORK RACK SPACE FOR AVAYA FLOOR MOUNTED STEP - DOWN TRANSFORMER. 480V, 30, 3 -WIRE PRIMARY, 120/208V, 30, 4 -WIRE SECONDARY, REFER TO TRANSFORMER LOAD SUMMARY SPACE FOR LOCAL EXCHANGE CARRIER SPENCER /AVAYA 66 QUIPCK SPACE FOR VARIOUS MUSIC SYSTEMS PLAY NETWORK RACK 21"X21 "X19" REFERENCE POINT FPB -1 ISC = 15,020A 6" FPB -2 C PANEL "A" ISC = 4,323A ISC = 13,799A 8' -0" PANEL 'B' MINIMUM WALL SPACE REQUIREMENT: FPB -3 - 3" MIN (TYP.) m LIGHTING CONTROL TIMECLOCKS ISC = 4,218A BACK PANEL # N1P2020L BY HUBBELL. LANDLORD PROVIDED MAIN DISCONNECT MEANS FOR TENANT IN A LANDLORD ELECTICAL ROOM AS WELL AS CONDUIT AND CONDUCTORS (FEEDER) FROM THE MAIN DISCONNECT MEANS TO A LANDLORD PROVIDED FUSED DISCONNECT SWITCH LOCATED WITHIN THE TENANT SPACE. IF NEEDED TO ACCOMMODATE TENANT CONSTRUCTION, THE TENANT SHALL RELOCATE THE LANDLORD PROVIDED DISCONNECT SWITCH AND ASSOCIATED FEEDER. TENANT SHALL FURNISH AND INSTALL CONDUIT AND CONDUCTORS FROM FUSED DISCONNECT SWITCH TO TENANTS' MAIN FUSED DISCONNECT SWITCH OR MAIN CIRCUIT BREAKER EQUIPPED PANELBOARD. FLOOR ELECTRICAL GEAR BILL OF MATERIALS FPB -1 LGETHN3361 30 AMP 480V NF 3P 4W NEMA 1 DISCONNECT SWITCH FPB-2 LGETHN3361 30 AMP 480V NF 3P 4W NEMA 1 DISCONNECT SWITCH FPB -3 LEV1221 SI (LEVITON) 2 -POLE SINGLE THROW A/C TOGGLE SWITCH EWH TC2368 30 AMP 208V NF 2P 4W NEMA 1 DISCONNECT SWITCH ........ ...... .... . REVIEWED FOR CODE COMPLIANCE E NFPA PEAR 2 0 200E City Of Tukwila BUILDING D I. N • POWER RISER DIAGRAM AND NOTES 100 FAULT CURRENT CALCULATIONS FAULT CURRENT AT INCOMING SERVICE* *FROM EXISITNG LANDLORD DRAWINGS FAULT CURRENT AT PANEL A f 1.73xLxI C x EL -L M= 1 1 + f ISCA = I x M FAULT CURRENT AT XFMR PRIMARY f 1.73xLxI C x EL-L M = 1 1 + f ISCA= IxM FAULT CURRENT AT XFMR SECONDARY f = IP(SCA) x VP x 1.73 x ( %Z) 100,000 x KVA M = 1 1 + f ISCA = (VP/VS) x I x M FAULT CURRENT AT PANEL B f = 173 x Lx I C x EL -L M = 1 1 + f ISCA IxM = 1.73 x 75 x 24.638 10,400 x 480 = 1 1.640 24,638 x 0.610 = 1.73 x 5 x 15.020 3,060 x 480 - 1 1.088 15,020 x 0.919 • 13.799_y 480 x 1.73 _c 2.5 100,000 x 45 = 1 7.366 = (480/208) x 13,799 x 0.136 1.73 x 5 x 4.323 7,190 x 208 1 1.025 = 4,323 x 0.976 24,638 0.640 0.610 15,020 0.088 0.919 I 13,799 = 6.366 0.136 = I 4,323 I = 0.025 = 0.976 - I 4,218 I 1/2" = 1' -0" GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 CONSULTANT INFO: Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 A r I 1 I I LANDLORD PROVIDED MASTER METERING EQUIPMENT IN THE LANDLORD'S ELECTRICAL ROOM. THE LANDLORD -OWNED NETWORK METERING SYSTEM WILL METER TENANT POWER CONSUMPTION. A EWH EQUIPMENT IS SHOWN FOR REFERENCE ONLY I AND NOT TO SCALE. LIGHTING CONTACTORS (TYPICAL) CONTACTORS IN NEMA 1 HINGED WALL -MOUNT N1C SERIES ENCLOSURE # N1 C20206LP BY HUBBELL. BACK PANEL TO BE N 1 P SERIES ROOF POWER RISER DIAGRAM GENERAL NOTES 1. HVAC CIRCUIT BREAKERS SHALL BE "HACR" TYPE WHERE REQUIRED BY EQUIPMENT NAMEPLATE PER N.E.C. 2. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.C. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. 3. INSPECT AND TEST ALL EXISTING EQUIPMENT THAT WILL BE USED /REUSED. REPORT TO G.C. REGARDING ANY REQUIRED MAINTENANCE OR REPAIR ITEMS. 4. INSTALL A MINIMUM OF 1/2" HIGH BLACK ENGRAVED LETTERING ON ALL ELECTRICAL ENCLOSURE COVER PLATES, INDICATING PANELBOARD DESIGNATION, RELAY CONTACTOR, AND LIGHTING CONTACTOR WITHIN ENCLOSURE. WITHIN EACH ENCLOSURE PROVIDE A MINIMUM OF 1/2" HIGH PERMANENT PEN INDICATING EQUIPMENT DESIGNATION. NOTE TO ELECTRICAL CONTRACTOR UPON DELIVERY THE ELECTRICAL CONTRACTOR SHALL BE ULTIMATELY RESPONSIBLE FOR THE EQUIPMENT AND ACCESSORIES, INCLUDING THEIR UNLOADING, STORAGE, INSTALLATION AND START UP ON THE PROJECT. RECEIVED CITY OF FEB 1 9 2008 PERMIT CENTER NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188-2888 PROFESSIONAL STAMP: ARCHITECT INFO: McCall Design Group 550 Kearny Street Stine 710 San Francisco CA 94108 t. 415.2 58.8150 1.415.288. Www.mccalldeslgn.com ISSUE TYPE: PERMIT /BID 12/21 /07 ISSUE SCALE: 1/2"=1 DRAWN BY: RBC / MNH JOB NO.: 207338 SHEET TITLE: POWER RISER AND SCHEDULES Firm Registration No. 2002 SHEET NUMBER: E3 -0 PANELBOARD B NEMA ENCLOSURE 1 AIC RATING 10,000 PANEL TYPE AQ MOUNTING SURFACE NOTES BOTTOM FEED DESCRIPTION ACTUAL CONNECTED KW/KVA CCT NO. LOAD DESCRIPTION BKR SIZE BKR OPT NEC KW ACTUAL KW PHASE ACTUAL KW NEC BKR OPT BKR SIZE LOAD DESCRIPTION CCT NO. 1 LTG 1 -- SALES TRACK 20/1 6.8 M5 1.365 A 1.056 1.056 2A 20/1 LTG 1 - SALES 2 3 LTG 2 -- SALES TRACK 20/1 0 * 1.365 1.365 B 10�' - � _ _ �.�Q3_) 1.0 20/1 LTG 3 - ENTRY 4 5 LTG 1 - SALES TRACK 20/1 BKR OPT 1.330 1.330 C 0.280 0.280 LOADS ARE NON APPLIES TO ONLY 30 INA 20/1 LTG 3 - SHOW WINDOW 6 7 LTG 2 - SALES TRACK 20/1 2.667 1.295 1.295 A 0.320 0.320 3 20/1 LTG 1 - SALES CABINETS 8 9 LTG 2 - STOCKRM /SPECIAL 20/1 5 0.524 0.524 B 0.342 0.342 ' 1 20/1 OFFICE /RR - LTG /EF 10 11 CONTACTOR CONTROLS 20/1 LO 0 360_ 0.360 C 0.900 0.900 LO 20/1 LIGHTING EM /EX /NL 12 13 RECEPT - SALES 20/1 '1 \ 0.90C1§60 9.125 A 0. 20 . '0 LO 20/1 RECEPT - CASHWRAP (IG1) 14 15 RECEPT - SHOW WINDOW 20/1 9.963 0.720 0. 0 B 0.720 0.720 20/1 RECEPT - CASHWRAP 16 17 RECEPT - STOCKROOM 20/1 SPACE 0.180 0.180 C 0.360 0.360 LO 20/1 RECEPT - OFFICE (101) 18 19 EAS J -BOX 20/1 LO 0.360 0.360 A 0.360 0.360 LO 20/1 RECEPT - OFFICE (IG2) 20 21 RECEPT - STEAMER 20/1 1.200 1.200 B 0.360 0.360 CONNECTED 15.379 15.682 17.205 20/1 RECEPT - OFFICE (GEN) 22 23 RECEPT - STEAMER 20/1 1.200 1.200 C 0.360 0.360 LO 20/1 RECEPT - TEL. BOARD (IG1) 24 25 RECEPT - EMPLOYEE TC 29/1 0.180 0.180 A 0.360 0.360 LO 20/1 RECEPT - TEL. BOARD (IG2) 26 27 EWH 20/1 1.500 1.0 50 O.D00 B 0.360 0.360 LO 20/1 RECEPT - TEL BOARD (IG3) 28 29 A SPARE 20/1 0.000 C 0.180 0.180 20/1 RECEPT - MUSIC SYSTEM 30 31 RECEPT - REFRIGERATOR 20/1 GFCI 0.600 0.600 A 0.180 0.180 20/1 RECEPT - DEDICATED 32 33 DUCT DETECTORS 20/1 LO 0.200 0.200 B 0.360 0.360 20/1 RECEPT - NETWORK RACK 34 35 RECEPT -- MICROWAVE 20/1 1.500 1.500 C 0.360 0.360 20/1 RECEPT -- RESTROOMS 36 37 RECEPT - EWC 20/1 0.500 0.500 A 0.000 0.000 20/1 SPARE 38 39 FACP 20/1 LO 0.200 0.200 B 0.000 0.000 20/1 SPARE 40 41 FIRE /SMOKE DAMPERS 20/1 LO 0.200 0.200 C 0.000 0.000 20/1 SPARE 42 MAIN BREAKER VOLTAGE 208/120 PHASE 3 PANEL MAX AMPS 225A MAINS 150A MCB WIRE 4 OPTIONS ACTUAL CONNECTED N.E.C. CONNECTED 8.196 KW PHASE A 11.940 KW 9.054 KW PHASE B 11.689 KW 7.210 KW PHASE C 10.245 KW 94 AMPS 24.460 KW TOTAL 33.874 KW TRANSFORMER LOAD SUMMARY A DESCRIPTION ACTUAL CONNECTED KW/KVA DEMAND FACTOR ACTUAL DEMAND KW /KVA COIL VOLTAGE TRACK LIGHTING 5.64 1.25 7.04 CIRCUITS CONTROLLED GENERAL LIGHTING 4.42 1.25 5.53 1 ALL STORE LIGHTS GEN. PURPOSE RECEPTACLE 6.8 1.0 < 10KW 0.5 > 10KW 6.8 PHASE WIRE MOTOR(S) (208V) 0 1.0 + 25% LARGEST 0 2A FIXED ELECTRIC SPACE HTG. (208V) 0 * 1.0 0 120 AIR CONDITIONING EQUIPMENT (208V) 0 * 1.0 + 25% LARGEST ** 0 * ELECTRIC WATER HEATER 4.16 1.0 4.16 NEC KW MISCELLANEOUS LOADS 6.32 1.0 6.32 BKR OPT TOTAL NOTES: * USE GREATER VALUE OF THE TWO CATEGORIES WHERE ** 125% OF LARGEST COMPRESSOR MOTOR IN SYSTEM. MINIMUM REQUIRED TRANSFORMER CAPACffY: TRANSFORMER TO BE INSTALLED: 27.4 - CONCURRENT. ONE UNIT. 29.9 1 LOADS ARE NON APPLIES TO ONLY 30 INA 15/3 HACR 45 KVA 1.833 MANUFACTURER: GENERAL ELECTRIC DRY TYPE 2.667 HACR TRANSFORMER BILL OF MATERIALS TRANSFORMER LGE9T83B3873 45 KVA 3PH 480 TO 208Y/120V HIGH EFFICIENCY TRANSFORMER TRANSFORMER LUG KIT LGE9T18Y7241 LUG KIT FOR A 45 KVA TRANSFORMER PANELBOARD PANEL TYPE A NEMA ENCLOSURE MOUNTING 1 AIC RATING NOTES 25,000 COIL VOLTAGE CONTACT VOLTAGE AE SURFACE TOP FEED CIRCUITS CONTROLLED N.O. N.C. 1A 1 ALL STORE LIGHTS GENERAL ELECTRIC CR463L60 -AJA MAIN BREAKER VOLTAGE MAINS 480/277 PHASE WIRE 3 PANEL MAX AMPS OPTIONS 225A B- 1,2 2A 200A MCB 4 GENERAL ELECTRIC CR463L60 --AJA ELEC ENERGIZED ELEC HELD 120 600 30 r F , te a o q� 4 43998 ¢6 0 i . G1STE c .: E'"9sioNA0- `` EXPIRES 02/20/2010 No. 4 NEMA 1 CCT NO. LOAD DESCRIPTION BKR SIZE BKR OPT NEC KW ACTUAL KW PHASE ACTUAL KW NEC KW BKR OPT BKR SIZE LOAD DESCRIPTION - B -4,6 CCT NO. 1 FPB -1 15/3 HACR 1.833 1.833 A 2.667 2.667 HACR 25/3 FPB -2 2 3 3.052 3.052 B 2.667 2.667 4 5 1.833 1.833 C 5.409 5.409 6 7 FPB-3 15/ HACR 0.916 0.916 A 9.125 9.963 70/3 TRANSFORMER 8 9 SPACE B 9.125 9.963 10 11 SPACE C 9.125 9.963 12 13 SPACE A SPACE 14 15 SPACE B SPACE 16 17 SPACE C SPACE 18 ACTUAL CONNECTED 15.379 15.682 17.205 N.E.C. KW PHASE A KW PHASE B KW PHASE C KW TOTAL CONNECTED 16.096 16.399 17.922 KW KW KW KW 66 AMPS 48.267 50.417 CONTACTOR SCHEDULE EXTERNAL CONTACTOR LABEL EXTERNAL CONTACTOR PANEL LABEL SCENE MANUFACTURER MODEL TYPE COIL VOLTAGE CONTACT VOLTAGE CONTACT AMPERE RATING NO. OF POLES NEMA TYPE ENCLOSURE CIRCUITS CONTROLLED N.O. N.C. 1A 1 ALL STORE LIGHTS GENERAL ELECTRIC CR463L60 -AJA ELEC ENERGIZED ELEC HELD 120 600 30 6 NEMA 1 B- 1,2 2A 2 EMPLOYEE LIGHTS GENERAL ELECTRIC CR463L60 --AJA ELEC ENERGIZED ELEC HELD 120 600 30 r F , te a o q� 4 43998 ¢6 0 i . G1STE c .: E'"9sioNA0- `` EXPIRES 02/20/2010 No. 4 NEMA 1 B -3,7,9 3A SCALE: NOT TO SCALE 3 SPECIALTY LIGHTS GENERAL ELECTRIC CR463L60 -AJA ELEC ENERGIZED ELEC HELD 120 600 30 4 NEMA 1 - B -4,6 REMARKS: 1. THE ELECTRICALLY HELD CONTACTOR SPECIFIED, (MODEL NUMBER. CR463L20 -AJA), USES A G.E. 2 --POLE CONTACTOR, (MODEL NUMBER CR460XP32,) FOR TOTAL NUMBER OF POLES SEE NO. OF POLES COLUMN IN CONTACTOR SCHEDULE. PANEL SCHEDULE LEGEND BREAKER OPTIONS LO HANDLE - LOCK -ON DEVICE LF HANDLE - LOCK -OFF DEVICE GFCI GROUND FAULT CIRCUIT INTERRUPTER BREAKER HACR HEATING, A /C, & REFRIGERATION RATED BREAKER NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 CONSULTANT INFO: immi k Consu En Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSIONAL A 9 }. 0 ,� . Firm Registration STAMP: 4 f `l 2002 r F , te a o q� 4 43998 ¢6 0 i . G1STE c .: E'"9sioNA0- `` EXPIRES 02/20/2010 No. ARCHITECT INFO: McCall Design Group 550 Kearny Street Suite 710 San Francisco CA 94108 t. 4 1 5- 2 8 8. 8 1 5 0 f.41 5.288.8I81 www.mccalldesign.com ISSUE TYPE: PERMIT /BID 12/21/07 ISSUE SCALE: NOT TO SCALE DRAWN BY: RBC / MNH JOB NO.: 207338 SHEET TITLE: PANEL SCHEDULES SHEET NUMBER: E3 -1 CONTACTORS BILL OF MATERIALS 3A 1A LGECR463L20AJA LGECR463L20AJA ELECTRICALLY -HELD BASE W /2NO CONTACTS ELECTRICALLY -HELD BASE W /2NO CONTACTS 3A POWER BLOCK 1A POWER BLOCK LGECR460XP32 LGECR460XP32 ELECTRICALLY -HELD 2NO POWER BLOCK ELECTRICALLY -HELD 2NO POWER BLOCK 2A LGECR463L20AJA ELECTRICALLY -HELD BASE W /2N0 CONTACTS 2A POWER BLOCK LGECR460XP32 ELECTRICALLY -HELD 2NO POWER BLOCK PANEL A BILL OF MATERIAL INFO 1 PANELBOARD, TYPE AE (101) SINGLE SECTION PANEL TOP FEED SURFACE MNT 18 CKTS 3P4W 480Y/277V 25 KAIC SERIES RATED 200A 3 POLE SGLA4 MAIN 1 15A 1 POLE TEY 1 15A 3 POLE TEY 1 25A 3 POLE TEY 1 70A 3 POLE TEY 1 COPPER BUS 1000A PSI 1 NAMEPLATES 1 NATIONAL ACCT SPECL INSTR 4 GROUND -CU BOX BONDED TGC2 1 GROUND MAIN LUG TGL20 1 AB76B BOX 1 AF76SN FRONT 1 AEF3182KB INTERIOR AXE3B4 THIS PANEL WAS SERIERS RATED AT 25 KAIC WITH 200A SGLA4 MAIN BREAKER. UL SERIES CONNECTED RATINGS ARE IN PUBLICATION DET -008A. PANEL B BILL OF MATERIAL INFO 1 PANELBOARD, TYPE AQ (101) SINGLE SECTION PANEL BOTTOM FEED SURFACE MNT 42 CKTS 3P4W 208Y/120V 10 KAIC SERIES RATED 150A 3 POLE TQD MAIN 39 20A 1 POLE THQB 1 20A 1 POLE THQB -GF 1 30A 2 POLE THQB 1 COPPER BUS 1000A PSI 1 NAMEPLATES 1 NATIONAL ACCT SPECL INSTR 4 GROUND -CU BOX BONDED TGC2 1 GROUND MAIN LUG TGL20 1 AB76B BOX 1 AF76SN FRONT 1 AEF3424JBX INTERIOR AXQ3B4 RECEIVED CITY OF ' >>1iI FEB 19 2008 PERMIT CENTER NEW STORE LIGHT FIXTURE SCHEDULE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 TAG PROVIDED BY DESCRIPTION MANUFACTURER CATALOG NUMBER LAMP BALLAST MANUFACTURER CATALOG NUMBER WATTS VOLTS MOUNTING LOCATION REMARKS OWNER LANDLORD D7 x SURFACE MOUNTED DUAL CIRCUIT TRACK. LENGTH AS INDICATED PER DRAWINGS, WHITE FINISH CON —TECH LA18P N/A N/A N/A 120 TYPICAL SALES AREAS DISPLAY WINDOWS Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSIONAL STAMP: .03. H O,cjL :- `,' o . W.asy / . 7 o � -Q q 4-3998 0 FGISTE ��` �° ■F E6 /0 N AL t EXPIRES 02/20/2010 Firm Registration No. 2002 X ISSUE TYPE: PERMIT /BID 12/21/07 ISSUE TRACK MOUNTED LOW VOLTAGE INCANDESCENT MR16 TRACK HEAD. INTEGRAL ELECTRONIC TRANSFORMER, WHITE FINISH, SOLITE SOFTENING LENS, CLOSED BACK, LABELED FOR 35W MAX. CON —TECH CTL1216TNT35SP PHILIPS (1) 35MR16 /IR /NFL25 N/A SHEET NUMBER: E3-2 35 120 TYPICAL SALES AREAS, DISPLAY WINDOWS. 2 F5E X 1'x4' FLUORESCENT FIXTURE W/ PRISMATIC ACRYUC DIFFUSER ELECTRONIC BALLAST AND EMERGENCY PACK MERCURY #M106-232—OCT—ELB—EM PHILIPS (2) F32T8/TL830 ADVANCE REL- 2P32 —SC 62 120 SURFACE MOUNTED ON GYP. BD. OFFICE 2,5 F9 -4 X SURFACE MOUNTED SINGLE LAMP FLUORESCENT CHANNEL ELECTRONIC BALLAST. MERCURY MB- 128 —T5 —ELB -120 PHIUPS (1) F28T5 / 830 INTEGRAL ELECTRONIC KTE —T5- 228 /RS /MVP 28 120 FEATURE WALL LIGHTING MOUNTED WITHIN 2 F9RD -4 X STRIP MIRROR LIGHT, CLEAR ACRYUC TOP LEN FOR T5 LAMP, STAINLESS STEEL HARDWARE FINISH 48" LENGTH, 2.75" RECESS DEPTH LUMEN ART ILLUMINER LINEAR ILLBR- 48 "- 28WT5— RM —P95 PHILIPS (1) F28T5 / 830 ROBERTSON RSU135— T5 -120V 28 120 FITTING ROOMS 2 G1W -4 X 4' CHANNEL HUNG SINGLE LAMP CHANNEL SYMMETRIC REFECTOR WIRE GUARD ELECRTRONIC BALLAST MERCURY MIE6 -1- 132 —OCT— ELB —EM (STRIP) — • - _ ' -_ • =� _-- _____ - PHILIPS (1) F32T8/TL835 - - - - - - --_-__-_-_-_----_-__A- - _ PHILIPS (1) F32T8/TL835 ADVANCE REL- 1P32 —SC - - - - ADVANCE REL-1P32—SC ..- 32 y - - - 32 120 --- - - -- __-_._-__- __._.. . 120 UNFINISHED CEILING STOCKROOM _ --�-_.�� -_ _._y. ■■��_ __ UNFINISHED CEILING STOCKROOM - 2 2,5 G1 WE -4 _ -..-__ _ x _.__ - 4' CHANNEL HUNG SINGLE LAMP CHANNEL SYMMETRIC REFECTOR WIRE GUARD ELECRTRONIC BALLAST AND EM PACK - —__ MERCURY MIE6 -1- 132 —OCT— ELB --EM (STRIP) WG —MIE 6(WIRE GUARD) G1W -8 X 8' CHANNEL HUNG SINGLE LAMP CHANNEL SYMMETRIC REFECTOR WIRE GUARD ELECRTRONIC BALLAST MERCURY MIE6 -1- 132— OCT /8T —ELB (STRIP) WG —MIE 6(WIRE GUARD)(2) PHILIPS (2) F32T8/TL835 ADVANCE REL - 2P32 —SC 62 120 UNFINISHED CEIUNG STOCKROOM 1,2 G1WE -8 X 8' CHANNEL HUNG SINGLE LAMP CHANNEL SYMMETRIC REFECTOR WIRE GUARD ELECRTRONIC BALLAST AND EM PACK MERCURY MIE6 -1- 132— OCT /8T— ELB --EM (STRIP) WG —MIE 6(WIRE GUARD)(2) PHILIPS (2) F32T8/TL835 ADVANCE REL-2P32—SC 62 120 UNFINISHED CEILING STOCKROOM 1,2,5 P2 x 13" H X 9" DIAMETER PENDANT MOUNTED HALOGEN CONICAL CUSTOM PENDANT. POLISHED NICKEL FINISH, OPAL WHITE GLASS WITH CLEAR 1/4" UP MORRISON 4765-01/10 (BR CUSTOM) PHILIPS (1) BC6OBT15 /HAL /W N/A 60 120 TYPICAL CASHWRAP 2 P5 x PENDANT MOUNTED LINEAR LOW VOLTAGE MR11 SIGN LIGHTER, LENGTH AS NOTED, BI —PIN SOCKETS 4" O.C. LINEAR SPREAD LENSE, REMOTE TRANSFORMER, PAINTED ALUMINUM FINISH SPECIALTY UGHTING 303/B/E BI —PIN SOCKETS FOR 35 WATT MR11 GE Q35MR11 /NFL30 (FTH) N/A 35 (105W / LF) 120 EXTERIOR TRANSOM SIGNAGE 2, 4 P10 x 36" DIAMETER BOWL COMPACT FLUORESCENT DECORATIVE PENDANT, SATIN NICKEL FINISH, SAND ETCHED ACRYLIC, INTEGRAL ELECTRONIC BALLAST MORRISON 4837-01/33 — OAD" (STANDARD PRODUCT HAS 36" OVERALL DROP) PHIUPS (3) PLC18W /27/4P FULHAM WORK HORSE #33 54 120 TYPICAL SALES AREAS 2 R2 x 6" COMPACT FLUORESCENT DOWN UGHT, CLEAR CONE, WHITE TRIM, VERTICAL LAMP, ELECTRONIC BALLAST PRESCOUTE CFT- 632— EB— WTF602 (TRIM AND HOUSING) PHILIPS (1) PLT26W /35/4P /ALTO TRIAD C2642UNVBE 28 120 TYPICAL SALES AREAS, AND PASS THROUGH FITTING ROOMS, CORRIDORS, TOILET ROOMS (INSTALL FOR AREAS WHICH THE CEIUNG IS LESS THAN 11' -0 ") 2 R2E X 6" COMPACT FLUORESCENT DOWN LIGHT, CLEAR CONE, WHITE TRIM, VERTICAL LAMP, ELECTRONIC BALLAST, AND EMERGENCY PACK PRESCOUTE CFT- 632— EB— WTF602 (TRIM AND HOUSING) PHIUPS (1) PLT26W /35/4P /ALTO TRIAD C2642UNVBE 28 120 TYPICAL SALES AREAS, AND PASS THROUGH FITTING ROOMS, CORRIDORS, TOILET ROOMS (INSTALL FOR AREAS WHICH THE CEILING IS LESS THAN 11' -0 ") 2,5 R2 -1 X 6" COMPACT FLUORESCENT DOWN UGHT, CLEAR CONE, WHITE TRIM, VERTICAL LAMP, ELECTRONIC BALLAST PRESCOUTE CFT- 632— EB— WTF602 (TRIM AND HOUSING) PHILIPS (1) PLT32W /35/4P /ALTO TRIAD C2642UNVBE 32 120 TYPICAL SALES AREAS, AND PASS THROUGH FITTING ROOMS, CORRIDORS, TOILET ROOMS (INSTALL FOR AREAS WHICH THE CEIUNG IS GREATER THAN 11' -0 ") 2 R2E -1 x 6" COMPACT FLUORESCENT DOWN UGHT, CLEAR CONE, WHITE TRIM, VERTICAL LAMP, ELECTRONIC BALLAST, AND EMERGENCY PACK PRESCOUTE CFT- 632— EB--- WTF602 (TRIM AND HOUSING) PHILIPS (1) PLT32W /35/4P /ALTO TRIAD C2642UNVBE 32 120 TYPICAL SALES AREAS, AND PASS THROUGH FITTING ROOMS, CORRIDORS, TOILET ROOMS (INSTALL FOR AREAS WHICH THE CEILING IS GREATER THAN 11' ---0 ") 2,5 S10 X EXTERIOR CUSTOM DECORATIVE FLUORESCENT SCONCE. FROSTED GLASS 4" DIA. CYLINDER, BRUSHED NICKEL FINISH, INTEGRAL ELECTRONIC BALLAST. DIMENSIONS: 26 -1/2" H x 7" D x 6 -1/2" W MORRISON LIGHTING 5273 -02 /A PHILIPS (1) PL —L24W /830 INTEGRAL ELECTRONIC PROVIDED BY MORRISON 24 120 EXTERIOR ENTRY SCONCES 2 X1 x LED EXIT SIGN WITH 90 MINUTE BATTERY BACK —UP HIGH LITES —BP— PLED -5 —R (RED LETTERS) BP —PLED— 5 —G (GREEN LETTERS) LETTER COLOR PER CODE REQUIREMENTS INCLUDED WITH FIXTURE N/A 5 120 EXIT SIGNS 2 XE1 X RECESSED DECORATIVE EMERGENCY LIGHT WHITE STEEL HOUSING WITH POYCABONATE COVER WITH INTERGRAL TEST SWITCH LIGHTOLIER — SOLUTION SOLUTION — W —CL N/A (2) 35W MR16 INCLUDED N/A 70 120 THROUGHOUT SPACE 2 Z5 x 4 -5/8" DIA. RECESSED LOW VOLTAGE INCANDESCENT MR16 DOWN UGHT. INTEGRAL TRANSFORMER, SATIN CHROME CONE, WHITE TRIM, 3 -3/4" DIAM CEILING CUTOUT RSA MLV -3055 CLEAR CONE w /WHITE (TRIM) C -500 —MBA (HOUSING) LABEL FOR 35W MAX. OSRAM /SYLVANIA OR GE (1)35MR16/IR/NFL25 N/A 35 120 INTERIOR ENTRY AREA, 3 —WAY MIRRORS 2 Z7 x 4 -5/8" DIA. RECESSED LOW VOLTAGE INCANDESCENT MR16 DOWN LIGHT. INTEGRAL TRANSFORMER, CLEAR CONE, SATIN CHROME TRIM, REMODEL HOUSING, 3.625" DIAM CEILING CUTOUT RSA MLV3055 CLEAR CONE w /SATIN (TRIM) C--800 (HOUSING) LABEL FOR 20W MAX. OSRAM /SYLVANIA OR GE (1)20MR16/IR/FL40 N/A 20 120 TYPICAL CABINET (TOP SHELF) 2 Z8 X 4-3.1" DIA. RECESSED LOW VOLTAGE INCANDENSCENT MR16 DOWN LIGHT. INTEGRAL TRANSFORMER, CLEAR CONE, SATIN CHROME TRIM , REMODEL HOUSING,3 -75" DIAM CEILING CUTOUT RSA, MLV -3055 CLEAR CONE W /SATIN(TRIM), C 800(HOUSING), LABLE FOR 35W MAX. PHILIPS (1) 35MR16 /IR /NFL25 N/A 35 120 EXTERIOR ENTRY RECESS 2 REMARKS: Q 1 (2) 4 FT UNITS TANDEM WIRED 2 PROVIDE 12 EXTRA LAMPS FOR EACH LAMP TYPE. 3 SPECIFY OVER ALL DROP FOR FIXTURE BETWEEN 18 " MIN AND 48 " MAX. IF DIFFERENT THEN STANDARD 4 SPECIFY TOTAL LENGTH FOR FIXTURE. WATTAGE VARIES PER LINEAR FEET SPECIFIED. 5 EMERGENCY BALLAST TO BE A MINIMUM OF 1300 LUMENS FIXTURE OF 36 " OAD . ` I E1� R .nt 1ia CE NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Sauthcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 CONSULTANT INFO: �■ ....k Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSIONAL STAMP: .03. H O,cjL :- `,' o . W.asy / . 7 o � -Q q 4-3998 0 FGISTE ��` �° ■F l y� /0 N AL t EXPIRES 02/20/2010 Firm Registration No. 2002 ARCHITECT INFO: McCall Design Group 550 Kearny Sheet Suite 710 San Francisco CA 94108 t. 4 1 5. 2 8 8. 8 1 5 0 }.415.288.8181 www.mcaaIldesign.cam ISSUE TYPE: PERMIT /BID 12/21/07 ISSUE SCALE: NOT TO SCALE DRAWN BY: RBC / MNH JOB NO.: 207338 SHEET TITLE: LIGHT FIXTURE SCHEDULE SHEET NUMBER: E3-2 P " � . NEC Iy� 7 0 MAR 2 0 Sa City Of TuVala N BUILDIN D SI RECEIVED CITY OF - 1..): 'WILA FEB 1 9 2008 PEHMIT CENTER NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southeenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 CONSULTANT INFO: k Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSIONAL STAMP: \ ,B• Dq� r �,, o _. 43998 e I ss /ONM_E , ill L EXPIR 02/20/20rn Firm Registration No. 2002 ARCHITECT INFO: McColl Design Group 550 Keamy Street Suite 710 San Francisco CA 44108 }. 4 1 5. 2 8 8. 8 1 5 0 t.415.288.8181 www.mccalldesign.com ISSUE TYPE: PERMIT /BID 12/21 /07 ISSUE SCALE: NOT TO SCALE DRAWN BY: RBC / MNH JOB NO.: 207338 SHEET TITLE: ELECTRICAL DETAILS SHEET NUMBER: E4 -O _____ _ MANAGER'S OFFICE GENERAL NOTES 1. REFER TO CONDUIT RISER DIAGRAM FOR EMPTY CONDUIT SIZES. 2. FINAL CONNECTIONS, HUBS AND WIRING FOR POS AND TELEPHONE SYSTEMS ARE PROVIDED AND INSTALLED BY SPENCER ENGINEERING AND LUCENT TECHNOLOGY RESPECTIVELY. 3. FINAL CONNECTIONS AND WIRING FOR MUSIC AND INSTALLED BY PLAY NETWORK. SYSTEM ARE PROVIDED MANAGER'S DESK CODED NOTES 100) 4 —PLEX DATA JACK. INSTALL 4-11/16" SQ X 2-1/8" DEEP BOX WITH SINGLE GANG 1/2" PLASTER RING COVER. EXTEND CONDUIT FROM BOX TO NETWORK RACK. (101) IJ45 JACK FOR TIMECLOCK. INSTALL 4" SQ X 2 -1/8" DEEP BOX WITH SINGLE GANG PLASTER RING COVER. <102) TRAFFIC COUNTER. INSTALL 4" SQ X 2 -1/8" DEEP BOX WITH SINGLE GANG PLASTER RING COVER. EXTEND TRAFFIC COUNTER CONDUIT HOMERUN TO BOX. (103) ISOLATED GROUND QUADRAPLEX RECEPTACLE FOR NETWORK RACK. INSTALL IN 4" SQ X 2-1/8" DEEP BOX WITH TWO GANG 1/2" PLASTER RING COVER. LABEL "P05 ONLY" AND CIRCUIT AS INDICATED ON POWER PLAN AND PANEL SCHEDULE. (104) CONVENIENCE QUADRAPLEX RECEPTACLE FOR GENERAL USE POWER. INSTALL IN 4" SQ X 2-1/8" DEEP BOX WITH TWO GANG 1/2" PLASTER RING COVER. LABEL "CONVENIENCE" AND CIRCUIT AS INDICATED ON POWER PLAN AND PANEL SCHEDULE. 105 NUTONE BUZZER UNIT ON WALL. 200 (201) DUPLEX RECEPTACLE FOR STEREO SYSTEM EQUIPMENT. LABEL RECEPTACLE AS "STEREO ", AND CIRCUIT AS INDICATED ON POWER PLAN AND PANEL SCHEDULE. INSTALL 4" SQ. X 2 -1/8" DEEP BOX FOR STEREO SYSTEM WIRE WITH 1" CONDUIT AND PULLWIRE STUBBED UP TO ACCESSIBLE CEILING. VERIFY EXACT LOCATION WITH G.C. PRIOR TO ROUGH —IN. MANAGERS DESK ELEVATIONS 2" CONDUIT WITH PULLWIRE TO TELEPHONE UTILITY SERVICE. COORDINATE WITT -I LANDLORD AND /OR UTILITY CO. BUSHINGS ON ALL CONDUITS DUPLEX RECEPTACLE DEDICATED CIRCUIT 205 1=1 I G1 „ 2 35" „ 48" o =e NETWORK RACK 23" SPACE FOR AVAYA EQUIP ADT 60" 24" DUPLEX RECEPTACLE 6" 21" 11 11 30" SPACE FOR LOCAL EXCHANGE CARRIER SPENCER /AVAYA 66 BLOCK EQUIP 204 SPACE FOR VARIOUS PLAY NETWORK SYSTEM S PLAY NETWORK RACK 21 "X21 "X19" 21" 1 00 " IG3 1, 96" p / j ' / / / ' / / / / / // / / / / / / / / / / / / / / / / /' / // / /' / / /// "./ ///\\ \\/ < ' / \ \ / \ "/ / \ \ \ \\ \ /\�„ /\ /\f /\ \\�\ /,� �� i /� \ /j� 24" 30" A.F.F. 10" A.F.F. FINISHED FLOOR 208 ISOMETRIC TELEPHONE SYSTEM DETAIL NOTES: 3/4" THICK PLYWOOD TELEPHONE BOARD. SIZE AS INDICATED. PHONE SYSTEM GROUND. DEDICATED ISOLATED #12 AWG SOLID COPPER GROUNDING WIRE OF LENGTH NOT TO EXCEED 35 FEET TO A "GE POWERMARK GOLD" EQUIPMENT GROUND BUS BAR CATALOG NUMBER TGK12 OR EQUAL. IF WIRE EXCEEDS 35 FEET, PROVIDE #10 AWG SOLID COPPER GROUNDING WIRE WITH REDUCING CUP AT BUS BAR. DEDICATED QUADRAPLEX RECEPTACLE CIRCUITED WITH AN ISOLATED GROUND. REFER TO POWER PLAN FOR CIRCUIT NUMBER. CONDUIT WITH PULL WIRE. REFER TO CONDUIT RISER DIAGRAM FOR QUANTITIES AND SIZES. IDENTIFY BOUNDARY LINES AND SPACE USE WITH PAINT OR PERMANENT MARKER AS INDICATED. 1/2" THREADED GALVANIZED STEEL PIPE CONNECTED TO FLOOR AND WALL MOUNTED ESCUTCHEONS. SEE ISOMETRIC. 4" X 4" X 1/2" JUNCTION BOX FOR PLAY NETWORK MUSIC SYSTEM. (2) 3/4" CONDUITS FOR SPEAKER WIRE AND ADDITIONAL PLAY NETWORK EQUIPMENT. (2) 3/4" CONDUIT TO ADT DEVICES. TELECOM BACKBOARD DETAIL I NOT TO SCALE 201 NOT TO SCALE 200 BUZZER AT MANAGER'S WORKSTATION FIELD— INSTALLED STORE FRONT ADT DEVICES TEMPORARY CASHWRAP AT BACKBOARD CASH WRAPS 2T CLASS II LOW VOLTAGE WIRING, 16AWG MINIMUM FIELD — INSTALLED (TYP) DELIVERY DOOR PUSHBUTTON. LABEL "GAP" FIELD— INSTALLED — — q (2) 3/4" (ADT) 3/4" (POS) 1 -1/2" (POS) TIME CLOCK MOUNTING DETAIL r I- YY Y1. Y LANDLORD WILL PROVIDE A COMMUNICATION CABLE TRAY LOCATED IN THE UTILITY CORRIDOR FOR TENANT'S USE. NO CONDUIT WILL BE PROVIDED. LANDLORD WILL PROVIDE A COMMUNICATIONS TERMINAL BOARD WITHIN EACH LANDLORD ELECTRICAL ROOM. TENANT SHALL PROVIDE AND INSTALL A COMPLETE TELEPHONE SERVICE SUPPORT FACILITIES AS REQUIRED BY THE SERVING TELEPHONE COMPANY. ALL TENANT TELEPHONE EQUIPMENT SHALL BE CONTAINED WITHIN THE TENANT'S SPACE. TENANT'S TELEPHONE EQUIPMENT IS NOT PERMITTED IN LANDLORD'S TELEPHONE EQUIPMENT ROOM. TENANT SHALL PROVIDE PLENUM RATED WIRE FROM THE TELEPHONE ROOM TO THE TENANT'S TELEPHONE EQUIPMENT WITHIN THE DEMISED PREMISES UTILIZING THE LANDLORD SUPPLIED CABLE TRAY. ANY CORRIDOR WALL PENETRATIONS WILL NEED TO BE FIRE CAULKED AS REQUIRED. TELECOM BACKBOARD d. J EAS BACKBOARD TIME CLOCK SUPPLIED AND INSTALLED BY SPENCER ENGINEERING RJ45 PHONE JACK BY TELEPHONE SUB — CONTRACTOR. DUPLEX RECEPTACLE FOR TIME CLOCK AND /OR GENERAL USE INSTALLED BY ELECTRICAL CONTRACTOR. 120V FACTORY WIRED TO CASHWRAP CIRCUIT 1 mm 10V (ADT BACP) (NETWORK RACK) (MUSIC) (SPENCER /AVAYA) (PHONE) 3/4 "C WITH ONE PULLWIRE TO MANAGER'S OFFICE. Y+ ♦ - Y Y n YY n Y +48" A.F.F. (TYP.) TRANSFORMER FACTORY PROVIDED IN CASHWRAP NOTE: CLEAR SPACE OF 30"W X 48 "D MUST BE PROVIDED IN FRONT OF THE TIME CLOCK AND TIME CARD RACK. DISPLAY KEYBOARD BUZZER FACTORY PROVIDED IN CASH WRAP FACTORY WIRED IN CASHWRAP "� FIELD —WIRED BY E.C. BUZZER SYSTEM NOTES: NUTONE DOOR BUZZER SYSTEM COMPONENTS WILL BE OWNER FURNISHED AND SHIPPED TO THE JOBSITE WITH THE CASHWRAP. THE TRANSFORMER AND ONE BUZZER WILL BE WIRED AND INSTALLED BY THE CASHWRAP MANUFACTURER. ELECTRICAL CONTRACTOR SHALL INSTALL A BUZZER IN MANAGER'S OFFICE AND A PUSHBUTTON OUTSIDE THE DELIVERY DOOR. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL NECESSARY JUNCTION BOXES, CONDUIT AND WIRE FOR A COMPLETE AND FULLY OPERATIONAL DELIVERY DOOR BUZZER SYSTEM. INSTALL COMPLETE SYSTEM IN CONDUIT IF REQUIRED BY CODE. A. BUZZERS (2) NUTONE #LA -201 (6 -10 VOLT): LOCATE FIRST BUZZER UNDER SWITCH PLATE AT +7' —O" A.F.F. IN STOCK ROOM AREA ABOVE MANAGER'S WORKSTATION, OR AS DIRECTED BY GAP'S REPRESENTATIVE (PAINT PLATE TO MATCH WALL COLOR). SECOND BUZZER AND TRANSFORMER WILL BE FACTORY INSTALLED IN THE CASHWRAP AND WIRED BY THE CASHWRAP MANUFACTURER. B. PUSHBUTTON (1): NUTONE #PB -18 LCL OR EQUAL. LOCATE PUSHBUTTON OUTSIDE DELIVERY DOOR. +48" A.F.F. C. TRANSFORMER (1) NUTONE #515T. INSTALLED IN THE CASHWRAP AND WIRED BY THE CASHWRAP MANUFACTURER. (2) 3/4 1 /2" (TEL) 1/2" (TEL) MANAGER'S OFFICE POS STOCKROOM PHONE FITTING ROOM PHONE Y 1r V Y Y 11 3/4" (POS) 3/4" (POS) +36" A.F.F. TO BOTTOM OF JACK DOOR BUZZER DETAIL CONDUIT RISER DIAGRAM - 2T CASHWRAP YY YY YY rY - q11/""V NOT TO SCALE 100 REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC PEAR 2 0 2008 City Of Tukwila BUILDING DIVISION NOT TO SCALE 202 EMPLOYEE TIME CLOCK TRAFFIC COUNTER RECENED CITY OF Tip K WILA FEB 1 9 2008 PEHMIT CENTER NOT TO SCALE 203 e LABEL LOCATION (TYP) I I 1/2" HIGH ENGRAVED LETTERING (TYP) COVER PLATE LIGHTING CONTACTOR OR CONTROL RELAY (TYP) LABEL LOCATION (TYP) 1" HIGH BLACK PERMANENT PEN (TYP) INSIDE ENCLOSURE LOCATE RELAYS IN ENCLOSURE WHEN APPLICABLE 20" x 20" LIGHTING CONTACTOR ENCLOSURE LABELING NOT TO SCALE 305 LABEL "ALL STORE LIGHTS TIMECLOCK" WITH 1/8" HIGH BLACK ENGRAVED LETTERING SET SCHEDULE FOR 10AM TO 9PM - � ALL STORE LIGHTS LABEL "EMPLOYEE LIGHTS TIMECLOCK" WITH 1/8" HIGH BLACK ENGRAVED LETTERING SET SCHEDULE FOR 8AM TO 11PM EMPLOYEE LIGHTS BLACK BYPASS BUTTON, SEE SHEET E2-0 FOR LOCATION TAPE OFF GREEN/YELLOW "277V GROUND" LABEL "SPECIALTY LIGHTS TIMECLOCK" WITH 1/8" HIGH BLACK ENGRAVED LETTERING SET SCHEDULE FOR 8AM TO 11PM SPECIALTY LIGHTS L REFER TO SHEET E1 -0 FOR CIRCUIT NUMBER AND LOCATION OF DEVICES 1 — — 001) o ff© N.O. I �I II N.C. — CD BP I (301) o� © o . o. n N.C. 120VAC DEDICATED CIRCUIT WITH LOCK —ON CIRCUIT BREAKER RED — GREEN "120V GROUND " 304 N.0 STOREFRONT SIGNAGE AND LIGHTING TIME CLOCKS SHALL BE SET TO MALL'S OPERATING HOURS. L N.C. N EXTERNAL CONTACTOR (TYP) (SCENE 1) (SCENE 2) (SCENE 3) LIGHTING CONTROL CODED NOTES (303) TORK MODEL #EW120BC, 7 DAY DIGITAL TIME CLOCK WITH SKIP —A —DAY FEATURE IN A NEMA 1 ENCLOSURE, WITH ONE N.O. 20 AMP AND ONE N.C. 10 AMP RATED CONTACTS. TORK MODEL #2001 PHOTOCELL, 120VAC RATED N.C. CONTACT. INSTALL PHOTOCELL FACING NORTH AND AWAY FROM ANY LIGHTING SOURCE. BYPASS BUTTON, SET AT 2 HOURS. TORK MODEL #SSA200 (304) RELAYS (WITH 2 N.O. AND 2 N.C.) CONTACTS, G.E. MODEL #MCRA022ATJ. LOCATE CONTROL RELAYS IN 20" X 20" CONTACTOR ENCLOSURE. SEQUENCE OF OPERATION SCENE 1 — ALL STORE LIGHTS TIMECLOCK LIGHTS ON (10AM -9PM ADJUSTABLE): TIMECLOCK NORMALLY CLOSED CONTACT OPENS AND DE— ENERGIZES SCENE 1 CONTACTOR(S). CONTACTOR(S) NORMALLY CLOSED CONTACTS CLOSE AND ENERGIZE LIGHTS. LIGHTS OFF (9PM-1 OAM ADJUSTABLE): TIMECLOCK NORMALLY CLOSED CONTACT CLOSES AND ENERGIZES SCENE 1 CONTACTOR(S). CONTACTOR(S) NORMALLY CLOSED CONTACTS OPEN AND DE— ENERGIZE LIGHTS. SCENE 2 — EMPLOYEE LIGHTS TIMECLOCK LIGHTS ON (8AM-1 1 PM ADJUSTABLE): TIMECLOCK NORMALLY CLOSED CONTACT OPENS AND DE— ENERGIZES SCENE 2 CONTACTOR(S). CONTACTOR(S) NORMALLY CLOSED CONTACTS CLOSE AND ENERGIZE LIGHTS. LIGHTS OFF (1 1 PM -8AM ADJUSTABLE): TIMECLOCK NORMALLY CLOSED CONTACT CLOSES AND ENERGIZES SCENE 2 CONTACTOR(S). CONTACTOR(S) NORMALLY CLOSED CONTACTS OPEN AND DE— ENERGIZE LIGHTS. BYPASS BUTTON FOR SCENE 2 BYPASS BUTTON ENABLED: BYPASS BUTTON CLOSES AND ENERGIZES BYPASS RELAY R-1. RELAY R -1 NORMALLY CLOSED CONTACT OPENS AND DE— ENERGIZES SCENE 2 CONTACTORS. CONTACTOR(S) NORMALLY CLOSED CONTACTS CLOSES AND ENERGIZES LIGHTS. SCENE 3 — SPECIALTY LIGHTS TIMECLOCK LIGHTS ON (8AM-11PM ADJUSTABLE): TIMECLOCK NORMALLY CLOSED CONTACT OPENS AND DE— ENERGIZES SCENE 3 CONTACTOR(S). CONTACTOR(S) NORMALLY CLOSED CONTACTS CLOSE AND ENERGIZE LIGHTS. LIGHTS OFF (11PM-8AM ADJUSTABLE): TIMECLOCK NORMALLY CLOSED CONTACT CLOSES AND ENERGIZES SCENE 3 CONTACTOR(S). CONTACTOR(S) NORMALLY CLOSED CONTACTS OPEN AND DE— ENERGIZE LIGHTS. LIGHTING CONTROL DIAGRAM NOT TO SCALE 300 NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 PROFESSIONAL STAMP: EXPIRES 02/20/2010 I ARCHITECT INFO: McCall Design Group 550 Kearny Street Suite 710 San Francisco CA 94108 7 . 4 1 5. 2 8 8. 8 1 5 0 f.415. 288 -8181 www. macalldesign.com CONSULTANT INFO: Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744-4400 EEA Project # 2079563 Firm Registration No. 2002 CITY )F • ILA FEB 1 9 2008 PERMIT CENTER ISSUE TYPE: PERMIT /BID ISSUE SCALE: NOT TO SCALE DRAWN BY: RBC / MNH JOB NO.: 207338 SHEET TITLE: ELECTRICAL DETAILS SHEET NUMBER: E4 -1 12/21/07 L_XI FIAI LWr ROOM WOMEN MEN'S FITTING BOON MGR'S ' / RLA 3 N v loo 1 FIRE ALARM FLOOR PLAN FA -1 / 1/8" = 1' -0" SALE S AR 2 SALES AREA 1 ) FLAY ETA1 DI AY 'A FIRE ALARM CODED NOTES (100) DUCT MOUNTED SMOKE DETECTOR. WIRE THE THERMOSTAT FAN WIRE THROUGH THE NORMALLY CLOSED CONTACT ON THE SMOKE DETECTOR TO SHUT DOWN THE HVAC UNIT UPON SENSING SMOKE. SMOKE DETECTOR MUST BE INSTALLED IN AN ACCESSIBLE LOCATION. INSTALL REMOTE TEST /RESET STATION AS REQUIRED. COORDINATE LOCATION OF TEST STATION WITH G.C. SMOKE DETECTOR TO BE WIRED TO ACTIVATE FIRE ALARM SYS I EM UPON SENSING SMOKE. SEWED FOR CODE COMPLIANCE NFPA 70 - NEC MAR 2 0 2008 Oty Of Tukwila B ILDIN .. D . ION RECEIVED CITY OF TU `WILA FEB 19 2008 PERMIT CENTER FIRE ALARM SYSTEM DEVICE LOCATIONS ON ENGINEERED ELECTRICAL DRAWINGS ARE FOR SCHEMATIC AND BIDDING PURPOSES ONLY. FIRE ALARM SYSTEM CONTRACTOR SHALL SUBMIT FIRE DRAWINGS, EQUIPMENT CUT SHEETS, ETC... PER LOCAL CODE AND NFPA72 TO LOCAL AUTHORITIES HAVING JURISDICTION AND OWNER'S INSURANCE COMPANY FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. ELECTRICAL ENGINEER WILL NOT APPROVE FIRE ALARM DRAWINGS, EQUIPMENT CUT SHEETS, ETC. INCLUDE IN BID ALL COSTS FOR PERMITS AND FEES. ALL PANELS AND PERIPHERAL DEVICES SHALL BE STANDARD PRODUCT OF SINGLE MANUFACTURER AND SHALL DISPLAY THE MANUFACTURER'S NAME ON EACH COMPONENT. ACCEPTALE MODELS (UNLESS LANDLORD REQUIRES DIFFERENT): SILENT KNIGHT 5204 OR 5207, ADEMCO 100, FIRELITE 9200 SERIES. BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 NEW STORE STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 CONSULTANT INFO: SHEET TITLE: FIRE ALARM PLAN SHEET NUMBER: Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSIONAL STAMP: ARCHITECT INFO: McColl design Group 550 Kearny Street Suite 710 San Francisco CA 94108 1. 4 1 5. 2 8 8. 8 1 5 0 1. 41 5.288.81 81 www.mccolldesign.com ISSUE TYPE: PERMIT /BID 12/21/07 ISSUE SCALE: 10=1 DRAWN BY: RBC / MNH JOB NO.: 207338 EXPIRES 02/20/2010 Firm Registration No. 2002 FAI -O TOILET ROOM TOILET ROOM " AREA OFFICE : --Fil r .... I \\ E .. • ... K57 7- � Ell � r:.- o v 1- 1,..1 L �� ) r ' I 07 O 11 t :1 .. _ O � _ \' 5cd 5cd 1 1 r z - _ _ 1 L ' J 45cd 45cd 45cd 1 8 .- .. E � __ - - __ .._ _ _- III - -.._ -- ENTR - , Q 100 AY 75cd 15cd 100 r . - - -. 1I DI i _. V _ �__. O • Q I4L] l V C -- V 0 AR1 © - 45cd 45cd 45cd lii i I• j[ 1 s __ -_ __._ - - 1 �T —t,: FPB �l 1_ <> alb :7 _ O I O i O.. - ' 7 ----- T I . L. I ~ �• -. ��_ ~ �� ~~ ~ ��' -ti_�� • �. - ��� - _. �...... -... �..._• _- •_• -__ _yam— .�- �•'�� FR ____ .. - -. - L_XI FIAI LWr ROOM WOMEN MEN'S FITTING BOON MGR'S ' / RLA 3 N v loo 1 FIRE ALARM FLOOR PLAN FA -1 / 1/8" = 1' -0" SALE S AR 2 SALES AREA 1 ) FLAY ETA1 DI AY 'A FIRE ALARM CODED NOTES (100) DUCT MOUNTED SMOKE DETECTOR. WIRE THE THERMOSTAT FAN WIRE THROUGH THE NORMALLY CLOSED CONTACT ON THE SMOKE DETECTOR TO SHUT DOWN THE HVAC UNIT UPON SENSING SMOKE. SMOKE DETECTOR MUST BE INSTALLED IN AN ACCESSIBLE LOCATION. INSTALL REMOTE TEST /RESET STATION AS REQUIRED. COORDINATE LOCATION OF TEST STATION WITH G.C. SMOKE DETECTOR TO BE WIRED TO ACTIVATE FIRE ALARM SYS I EM UPON SENSING SMOKE. SEWED FOR CODE COMPLIANCE NFPA 70 - NEC MAR 2 0 2008 Oty Of Tukwila B ILDIN .. D . ION RECEIVED CITY OF TU `WILA FEB 19 2008 PERMIT CENTER FIRE ALARM SYSTEM DEVICE LOCATIONS ON ENGINEERED ELECTRICAL DRAWINGS ARE FOR SCHEMATIC AND BIDDING PURPOSES ONLY. FIRE ALARM SYSTEM CONTRACTOR SHALL SUBMIT FIRE DRAWINGS, EQUIPMENT CUT SHEETS, ETC... PER LOCAL CODE AND NFPA72 TO LOCAL AUTHORITIES HAVING JURISDICTION AND OWNER'S INSURANCE COMPANY FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. ELECTRICAL ENGINEER WILL NOT APPROVE FIRE ALARM DRAWINGS, EQUIPMENT CUT SHEETS, ETC. INCLUDE IN BID ALL COSTS FOR PERMITS AND FEES. ALL PANELS AND PERIPHERAL DEVICES SHALL BE STANDARD PRODUCT OF SINGLE MANUFACTURER AND SHALL DISPLAY THE MANUFACTURER'S NAME ON EACH COMPONENT. ACCEPTALE MODELS (UNLESS LANDLORD REQUIRES DIFFERENT): SILENT KNIGHT 5204 OR 5207, ADEMCO 100, FIRELITE 9200 SERIES. BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 NEW STORE STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 CONSULTANT INFO: SHEET TITLE: FIRE ALARM PLAN SHEET NUMBER: Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSIONAL STAMP: ARCHITECT INFO: McColl design Group 550 Kearny Street Suite 710 San Francisco CA 94108 1. 4 1 5. 2 8 8. 8 1 5 0 1. 41 5.288.81 81 www.mccolldesign.com ISSUE TYPE: PERMIT /BID 12/21/07 ISSUE SCALE: 10=1 DRAWN BY: RBC / MNH JOB NO.: 207338 EXPIRES 02/20/2010 Firm Registration No. 2002 FAI -O NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 /� / I \ CONSULTANT INFO: k Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSIONAL STAMP: ASS /ONAL ANC',= ?1 EYPIRES 02 .DJ?:i4_i Firm Registration No. 2002 ARCHITECT INFO: McCall Design Group 550 Kearny Street Suite 710 San Francisco CA 94108 t. 4 1 5. 2 8 8. 8 1 5 0 f . 4 1 5 . 2 8 8 . 8 1 8 1 www.mccalldesign.com ISSUE TYPE: PERMIT /BID 12/21/07 ISSUE SCALE: 118" = 1` -0" DRAWN BY: RBC / MNH JOB NO.: 207338 SHEET TITLE: SECURITY ALARM PLAN SHEET NUMBER: LPI-O EXI F _ iAl._LWAY WOMEN'S v1LN'S r FITTING ROOM MGR'S . 011 ET ROOM TOILET ROOM AREA OFFICE SALES AREA 3 SALE. SECURITY ALARM PLAN 1/8" =1 Q LP LEGEND 35' PIR RECESSED CONTACT SURFACE CONTACT KEYPAD SOUNDER 360 M0110N DETECTOR DISPLAY AREA 1 FN TRY DISPLAY AREA 2 REVIEWED FOR CODE COMPLIANCE NFPA 70 MAR 2 0 rata O�y �f Tukwila !WING D-ION � RECEI'.'ED CITY OF i f ;(. 7;..tiLA FEB 1 9 2008 PEHNIIT CENTER