ELECTRICAL PERMIT
Owner:
Name: WEA SOUTHCENTER LLC Phone:
Address: 11601 WI SHIRE BLVD , LOS ANGELES CA
Permit Number: EL07 -811
Issue Date: 06/11/2008
Permit Expires On: 12/08/2008
Contact Person:
Name: JEFF MCGARRY Phone: 617 - 824 -6403
Address: 191 SPRING ST , LEXINGTON MA
Contractor:
Name: SELECTECH ELECTRIC LLC Phone: 425 - 228 -6167
Address: 1427 QUEEN AVE NE , RENTON WA
Contractor License No: SELECEL935JW Expiration Date: 04/16/2009
DESCRIPTION OF WORK:
INTERIOR CONSTRUCTION OF RETAIL STORE; NEW FEEDERS FROM LL ROOM TO TENANT
SPACE, NEW POWER, LIGHTING PANELS AND DISTRIBUTION
Value of Electrical: $12,000.00
Fees Collected:
Type of Fire Protection: National Electrical Code Edition: 2005
$348.50
Electrical Service provided by: PUGET SOUND ENERGY
• ff
Permit Center Authorized Signature: - 5t Date: cI 4 4� 4fl�
I hereby certify that I have read and e • ed this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied whether specified herein or not.
The granting of this permit does not presume to 've authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance f work. I thorized to sign and obtain this electrical permit.
Signature:
Print Name: 12.4 -IV 00 LT I+
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -4/07
Date: l7 1 ( ^ � 2
EL07 -811 Printed: 06-11 -2008
Parcel No.: 6364200010
Address: 1077 SOUTHCENTER MALL TUKW
Suite No:
Tenant: STRIDE RITE
1: ** *ELECTRICAL * **
Signature:
Print Name:
doc: Cond -Elec
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
— 7 /1 - A) poLPFi
PERMIT CONDITIONS
Permit Number: ELO7 - 811
Status: ISSUED
Applied Date: 12/28/2007
Issue Date: 06/11/2008
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local
laws regulating construction or the performance of work.
Date:
EL07 -811 Printed: 06 -11 -2008
CITY OF:TUKWILA
Coitimuill*DiniekOent
Pprillit CROW
6300 SoiJthcenter 814,, Suite 100
Tokwila,064 98188
ELECTRICAL PERMIT APPLICATION
Applications and plans must be Complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax
**Please Print**
1 0-77 King Co Asiessor'S Tax No:: 4'i6 )-0 -00 1 0
Site Address: Ate Suite Numbcr I2c2 Floor
Tenant Name: "7"(ii6E:ter7E. New Tenant: Fr Yes 0 No
Property Owners Name: 71.-1 1../0.54 kivAcia)
Mailing Address:: #714 /ftkci Iry L6s4f4Rece$ 'roc 24 S
State Zip
Name: Lie•-•
Mailing Address M/
.E -Mail Address 6°— il1c52k-kri .0 .5"tielde *Ire • c;ovo.
Mailing Addmss:
Company Name:
City
Day Telephone: .6/7. e24
1--cwk CV4 V
city Slate Zip
Fax Number 7 - 644D3
State • "
Zip.
City
Contact Person: Day Telephone:
E-Mail Address Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Piojecticonttactor'S bid pike): $
Scope of Work (please provide detailed information): ./A-477-940'4 C/S CA=
AlgiN Enf:70 tfileort LL- Asice/i rir) A.ANK ACK/F-Z.
P
Will : serviCe be altered'? . Ef. Yes 0 .1•410 : Adding, more than - $4,.. 4 0-01 ::(2 :0 No
. ... . . ......
TYPe cif Oie: . / • ..
TV0e OlVVOrk:
0 New 0 Addition
0 Service Change :0 Remodel .g
0 , Lew.Voltage 0 Genera tor . 0 FireAlatin :0 TeleCOMEntiiiitatiOn : 0 • Temporary:Service
PronertyServed:by:
Puget Sound Energy
Seattle City Light
1APplicationsWirrits-ApPlieationi Ofs Lihel:4-2007 Wearied
Page t izif 2
NEWRESIDENTIAL SERVICE
b New singe family. dwellings 5140.00
(inchiding arteehed garage).
o Garages, pools, spas and outbuildings ST5.00 ea
OE L voltage systems
(efarin, furricoe thermostat) 5$100 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
O Service change or alteration $7$.1)0
(no added/altered eircUits)
O Service change .with added/altered circuits 575.00.
number Of added circuits 510.00 ea
O Circuits added/altered without service Change. 550.00
• :(Upto5 Circuits)
O Circuits addecitalieted without service change . . :550.00
(6 or more &CURS) 57.00:ea
• Meter/mastrepair .565.00.
0: Lbw voltage systems $55,00.
(alartu, runtime thermostat)
B 11211
Signat
Print Name.
Mailing Address:
RESIDENTIAL
1
It.■AOplIaltionaoans-ApplIaloong On Lan' oA4-2007 Elvetrical Permit Appliestandoc
6h
bL
MULTI-FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
O Temporary service (residential) S511.00
O Temporary service (generator) 575.00
O Manufactured/mobile home service • $80.00
(excluding garage or outbuilding)
O Carnivals
575.00.
•ttinber of concessions S10.00 ea
Value of Construction -.:In .alt cases, a value:of constructiortamount shouldbe entered by the applicant This figure will be reviewectand..issubject
to iiion by the Permit Center to comply with cintont fee schedules.
Expiration of Plan Role* Applications fOr Whiek iMperniit is issued within t80 days dateOf application sitaIttaisitety,
The Minding Official;may.grantone.:extension:oftiznefor au:additional:period not to exceed 96 days. The extensionshalLbe,reqtreStedia..W,riting
and justifiable cause: detnOitstrated.
1: HEREBYCERTIFY T I:1-IAVERFABAND THIS:APPLICATION KNOW TFIE SAME TO BE-TRUEVNIJER
PENALTY OF P!) THELAWSOF THE STATE OF WASHINGTON:AND-I AM AliTHORIZEDIO APPLY FOR THIS•PERMIT.
Date;
Day Telephone:
City State
I Date Application Accepted _ 7 1 Date Application Expires: Staff Initials: (Me I •
rage 2 of 2
Parcel No.: 6364200010 Permit Number: EL07 -811
Address: 1077 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 12/28/2007
Applicant: STRIDE RITE Issue Date:
Receipt No.: R08 -02069
Initials: JEM Payment Date: 06/11/2008 09:02 AM
User ID: 1165 Balance: $0.00
Payee: SELECTECH ELECTRIC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Cash 278.80
ACCOUNT ITEM LIST:
Description
ELECTRICAL PERMIT - NONR
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: //www.ci.tukwila.wa.us
RECEIPT
Account Code Current Pmts
000.322.101.00.0 278.80
Total: $278.80
Payment Amount: $278.80
3535 06/11 9711 TOTAL 278.80
doc: Receiot -06 Printed: 06-11 -2008
Receipt No.: R07 -02873
Initials: WER
User ID: 1655
ACCOUNT ITEM LIST:
Description
doc: Receipt -06
ELECTRICAL PLAN - NONRES
City of Tukwila
Parcel No.: 6364200010
Address: 1077 SOUTUCENTER MALL TUKW
Suite No:
Applicant: STRIDE RITE
Payee: NATIONAL SERVICES GROUP
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http:/ /www.ci.tukwila.wa.us
RECEIPT
TRANSACTION LIST:
Type Method Description Amount
Payment Check 333600 69.70
Account Code Current Pmts
000.345.832.00.0 69.70
Total: $69.70
Permit Number: EL07 - 811
Status: PENDING
Applied Date: 12/28/2007
Issue Date:
Payment Amount: $69.70
Payment Date: 12/28/2007 03:52 PM
Balance: $278.80
6615 12/31 9710 TOTAL 861.99
Printed: 12 -28 -2007
Project:
Type of Inspection:
Ad , .4C ���
Date Called:
S pecial Instructions:
Date Wanted:
a.m.
p.m.
Requester:
Phone No:
PERMIT N
CITY OF TUKWILA BUILDING DIVISION Iz
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
INSPECTION NO.
OMMENTS:
Inspct cf1 L`
$58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
(Receipt No.:
'Date:
INSPECTION RECORD
"Retairra copy with permit
roved per applicable codes. LJ Corrections required prior to approval.
t rrts 4I/ /I Dat /2(4 q
COMMENTS:
12 LAM-- , //V ('/?Ef4Xf2 / /v
1 /'0 V/ MI/E.,' L
Mai/ 0% Lm &!"L -5 MexiT'i 'X/G
V/o I- TG` f'/I)Z1 0/45 r Ui.-U/Z -S Fa
BLS
FGF_X 1/1i__ cpyobihr 'EGo )
__c
fiiviz, / NA Cyr 1)&1/ E ,,09AliC
10 4kOl'A/04 fa c-7720 E C.6i1A /lc-TN(
s)/ t L. SG/rGt /A) M■/EL ca/c4
6ial. v UPD//1y !c-e 64-4r
/ I7)aA r ,44 SC h4 /71/ //t) / 1r GF 77 j4tY
Phone No:
Pr
Type of Inspection;
/N/ /V / ' '
7 S� /44 L L
Date Called:
Special Instructions:
Date Wanted:
a.m.
p.m.
Requester:
Phone No:
INSPECTION RECORD
Retain a copy with permit
4 - /
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36V0
El Approved per applicable codes.
or ctions required prior to approval.
Imns I U
$58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
(Receipt No.:
!Date:
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
INSPECTION NO. Q
CITY OF TUKWILA BUILDING DIVISION 1
6 300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Type o Inspection: 700
Date Called:
Phone No:
Project:
Address: 101
Special Instructions:
- RAM RITE
Atit/
Approved per applicable codes.
Corrections required prior to approval.
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
'Date:
(Receipt No.:
Project:
1 T_/=
Type of Inspection:
'20.
`�.J
�� g, M t
A �� : SG
Special
/ /mi i••
Date Called:
Instructions:
Date Wanted:
/
l� /��
a.m.
p.m
Requester:
Phone No:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
tLo'7-
PERMIT NO.
g
(206)431 -3 0
CbMMENTS: i f"34,
c-4,1-//06- ( -
.si9 t45
( O4/7"
p roved per applicable codes. El Corrections required prior to approval.
inspenu_ At/773/<44,(,/i (Date: 4/z 7/ g
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
'Receipt No.:
'Date:
:4 +JI1=
Project:
Ji mt / /71
Type of Inspection:
76(j
Address:
/027 5c- /0i9GL
Date Called:
Special Instructions:
Date Wanted:
m.
Requester:
Phone No:
7 - F'//
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
El Approved per applicable codes. El Corrections required prior to approval.
COMMENTS: p
Inspe it.t
I / r
ID $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
'Receipt No.:
'Date:
1 r 1
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION tc
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: Type of Inspection:
$?Rt4E et7t
Address:
/ /4414/ Date Called:
Special Instructions:
INSPECTION RECORD
Retain a copy with permit
Date Wanted:
Requester:
Phone No:
70 0 2-
Z
a.m
D Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
1 lflspector:
'Date: /2./
I
n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
'Receipt No.:
(Date:
1
I Z
05 -08 -2008
JEFF MCGARRY
191 SPRING ST
LEXINGTON MA 02421
RE: Permit Application No. EL07 -811
1077 SOUTHCENTER MALL TUKW
Dear Permit Applicant:
In reviewing our current permit application files, it appears that your permit application applied for on 12/28/2007 , has not been
issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical
Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and
void. Your permit application expires on 06/25/2008 .
If you choose to pursue your project, a written request for extension of your application addressed to the Building Official,
demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 06/25/2008. If it is
determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date.
In the event we do not receive your written request for extension, your permit application will become null and void and your project
will require a new permit application, plans and specifications, and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
xc:
er Marshall
t Technician
Permit File No. ELO7 -811
City of Tukwila it Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
ACTIVITY NUMBER: EL07 - 811 DATE: 01 -28 -08
PROJECT NAME: STRIDE RITE
SITE ADDRESS: 1077 SOUTHCENTER MALL
Original Plan Submittal
Response to Correction Letter #
X Response to Incomplete Letter # 1
Revision # After Permit Issued
DEPARTMENTS:
ision
B
if
I
ing
Public Works
Complete
Comments:
Please Route
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUESJTHURS ROIdTING:
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ri Approved with Conditions Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS:
Documents/routing slip.doc
2 -28 -02
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
Fire Prevention ❑ Planning Division
Structural
Incomplete
Structural Review Required
❑ Permit Coordinator ❑
DUE DATE: 01 -29 -08
❑ No further Review Required
DATE:
DUE DATE: 02 -26 -08
DATE:
Not Applicable
C
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: ' Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
1)ERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: ELO7 -811 DATE: 12 -28 -07
PROJECT NAME: STRIDE RITE
SITE ADDRESS: 1077 SOUTHCENTER MALL
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS;
Bui d n g Ivl'" "sibn
Public Works ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 01-03-08
Complete
El
Comments:
TUES/THURS ROUTING:
Please Route ❑ Structural Review Required ❑ No further Review Required
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Fire Prevention
Structural
Incomplete
12/
DATE:
Planning Division
❑ Permit Coordinator
Not Applicable
DUE DATE: 01 -24 -08
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28-02
REVISION SUBMITTAL
1
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: V 2 Plan Check/Permit Number: & L 01 v ' I
/Response to Incomplete Letter #
❑ Response to Correction Letter #
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
STi21lo LIVE
Project Name: /� /
Project Address: ((c ) s 't- 7 �^ � t J S( C-e- r13
Contact Person: 3 P1 c Zoom' /L-J{0ti Number: to 'f /'
Summary of Revision:
(<7 r
Sheet Number(s):
"Cloud" or highlight all areas of revision including of revis ft—
Received at the City of Tukwila Permit Center by:
4 E --- Entered in Permits Plus on
City of Tukwila
\applications\forms - applications on Iine\revision submittal
Created: 8 -13 -2004
Revised:
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: //www.ci.tukwila.wa.us
`•,
Steven M. Mullet, Mayor
Steve Lancaster, Director
ALCOVED
CITY OF TUKWILA
JAN 28 200$
License Information
License
SELECEL935JW
Licensee Name
SELECTECH ELECTRIC LLC
Licensee Type
ELECTRICAL CONTRACTOR
UBI
602714463
Ind. Ins. Account Id
PARTNER/MEMBER
Business Type
LIMITED LIABILITY COMPANY
Address 1
110 EDMOND AVE NE
Address 2
City
RENTON
County
KING
State
WA
Zip
98056
Phone
4254305333
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
4/16/2007
Expiration Date
4/16/2009
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
EUSE *ZF939D6
Business Owner Information
Name
Role
Effective Date
Expiration Date
RANDOLPH, STEVE
PARTNER/MEMBER
04 /16/2007
EUSE, ZACHARY
PARTNER/MEMBER
04 /16/2007
Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2
Washington State Department of Labor and Industries
Electrical Contractor
A business licensed by L &I to contract electrical work within the scope of
its specialty. Electrical Contractors must maintain a surety bond or
assignment of savings account. They also must have a designated
Electrical Administrator or Master Electrician who is a member of the
firm or a full -time supervisory employee.
Electrical Administrator Information
License
Name
Status
EUSE *ZF939D6
EUSE, ZACHARY F
ACTIVE
Bond Information
1
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= SELECEL935JW 06/11/2008
LIGHTING RXTURE SCHEDULE
TYPE
DESCRIPTION
MOUNTING
LAMPS
FIXTURE
WATTS
VOLTS
MANUFACTURER
CATALOG NO.
SAME AS (11) EXCEPT 2 MOUNTED IN 2 GANG BOX WITH SINGLE COVER PLATE
0Ewe
SAME AS 0 EXCEPT MOUNTED BEHIND IDRI1KIN6 FOUNTAIN
*IG
SAME AS WITH ISOLATED GROUND, HJBBH_L TYPE 165362
0
SAME A51 ONLY RECESSED MOUNTED IN came
LT4
8 OPEN APERTURE DOWNUGHT
RECESSED
PL- C26W/35/4P/
ALTO 10PK
53
120
PATHWAY
FF8226/4E/CB
LAMP -P- 38336 -4
LT8
2'x2'x3" DEEP CELL PARABOLIC
RECESSED
PL- L4OW/35/
R5BIAX2G1125PK
80
120
UGHTOLIER
22- 9- 3BIAX -UNV
LAMPS- P30043 -4
LT8E
SAME AS TYPE 'LTB' EXCEPT WITH EMERGENCY
BATTERY BALLAST
RECESSED
PL- L4OW /35/
R5BIAX2G1125PK
80
120
LIGHTOLIER
22- 9- 3BIAX -UNV
LAMPS- P30043 -4
LT9
DUAL HEAD BATTERY EMERGENCY LIGHT
SURFACE
--
--
120
COOPER
PC20 -105Q
LT11
4' 2 -LAMP STRIP FIXTURE
SURFACE
F32T8/TL735
ALTOEAHV25PK
58
120
MERCURY
MM2320CTCELBMV
LT12
4' UNDERCABINET LIGHT
SURFACE
F13T51 CW
4100K 251PK
30
120
MERCURY
MUCI- 213 -RKS -A -120
LAMPS -P- 33253 -6
LT13
UNE VOLTAGE TRACK SYSTEM. TRACK SHALL
BE RECESS MOUNT OR CONCEALED
SURFACE
50W PAR30/
HALINFL3O
120V 15PK
50
120
CONTECH
CTL610P PAR HOLDER
LA63OP SHADE
LTBP & LT4P TRACK
& REQ'D CONNECTORS
LAMPS- P26358 -2
LT14
UNIVERSAL LED EXIT SIGN
SURFACE
--
4
120
PATHWAY
PEXUR -DL -LT
LT15
BATTERY UNIT WITH 2 REMOTE HEADS
SURFACE
--
4
120
PATHWAY
--
SYLEIOLS
$
20A- 120/217V SINGLE POLE TOGGLE SNITCH, RBBELL, TYPE CSI221, FSL. 1221
$r
20A -300'V MANJAL STARTING SNITCH W/ THERMAL OVERLOAD RELAY- IF NOT INTEGRAL
TO MOTOR - FLUSH MOUNTED IN WALL AND SURFACE MOUNTED AT EQUIPMENT ROOMS
SQUARE D CLASS 2510 (OR APPROVED)
20A -125 V DUPLEX RECEPTACLE, I-UBBELL, TYPE CR5362, 5562
{6 Gm
SAME AS ( EXCEPT WITH INTEGRAL_ 1 6F1' PROTECTION, t JBBELL TYPE 6F5552, 6F8300
SAME AS (11) EXCEPT 2 MOUNTED IN 2 GANG BOX WITH SINGLE COVER PLATE
0Ewe
SAME AS 0 EXCEPT MOUNTED BEHIND IDRI1KIN6 FOUNTAIN
*IG
SAME AS WITH ISOLATED GROUND, HJBBH_L TYPE 165362
0
SAME A51 ONLY RECESSED MOUNTED IN came
1 w
4' SG x 2 ^US' Dom' BOX WITH PLASTER RWN6 TO MATCH DEVICE FOR TELEPRXE AND /OR
DATA OUTLET - 51UB 3/4' GONDUIT INTO ACCESSIBLE GEILIN6 SPACE. PROVIDE LANK
B
COVER IF NOT WED BY OMER. N = DENOTES MOWED AT WALL PHONE HEIGHT - 46' AFF
O
5Y STANDARD JUNCTION BOX SIZED PER N.E.G. AND SUPPORTED INDEPENDENT OF CONDUIT
5 TEM
D D
fEVI -DUTY 3 POLE FUSIBLE DISCONWGT SNITCH Pi/FUSEFRONS 51ZE12 AS NOTED OR AT
I25% OF ACTUAL MOTOR NAMEPLATE RATING• - SWITCH SIZE AS NOTED
N.F. DalOTES NON- FUSIBLE - MOUNTED AT EQUIPMENT
WP. DENOTES NEATI-ERPROOF- MCUNrED AT EQUIPMI3'IT
00/000= DISGONIEGT SIZE / FUSE SIZE - MOUNTED AT EQUIPMENT
PREWIRED UNIT CONTROL PAN EL-GO NECT AND WIRE PER MF6RS. WIRING DIACRAM5.
PROVIDE DIET SNITCH AS REQUIRED BY NEC.
MOTOR CONNECTION AS NOTED-CONNECT WITH FLEXIBLE OR SEAL CONDUIT
'i l
:
!�
ThERMOSTAT CONNECTION, THERMOSTAT PROVIDED BY O1H1 , HIRED 4 INSTALLED BY E.G.
120/208V -3 PHASE-4 WIRE ELECTRICAL BRANCH CIRCUIT PANEL
2T10480V - 3 PHASE - 4 WIRE E EGTRiCAL BRANCH CIRCUIT PANE..
GONDUIT RUM EXPOSED, c7VERLEAD, CONCEALED ABOVE CEILING OR IN NALL CROSSHATCHES
DEMOTE NUMBER OF #I2 AP a COPPER 00 JGTORS UNLESS NOTED OTHERWISE. IF NO
CONDUCTORS ARE SHOWN PROVIDE 2 *I2 + CND. MINIMLI 1 OR AS R.EQIJIRED
GONDUIT RUN IN OR 13EL01✓d FLOOR SLABS - MAINTAIN 2" MINIMUM CONCRETE COVER ABOVE
CONDUIT - GRCSSHATCFES MOTE NUMBER OF *12 ANG COPPER CONDUCTORS UNLESS NOTED
OTHERWISE. IF NO CONDUCTORS ARE SHOWN PROVIDE 2 *I2 + GNP. MINIMUM OR AS REQUIRED
1 DAY TIME ("LOCK WITh-I CARRY OVER, 120V, 3 POLE, TORK POOL.
1!I
Q � L]
PULL STATION
AV HORN STROBE
ACCESSIBLE MODULE
MODULE
DUCT SMOKE DETECTOR
S 0.
I. ALL TOGGLE SWITCHES ARE TO BE FLUSH MOWIE) AT 48' AFF. TO CFA LINE
OF BOX AND BE PROVIDED WITH A 11- MOPLASTIG COVER PLATE TO MATCH
DEVICE UNLESS OTHERWISE SPECIFIED. COLOR OF DEVICE TO BE SELECTED BY
ARCHITECT. COMPLY WITH CURRENT ADA REGUJIRB"E1T5.
2. ALL RECEPTAGL.ES, 1UEPHO , ETC. ARE TO BE LUSH MOUNTED AT IS' A.F.F. TO
CENTER LINE AND BE PROVIDED WITH A TFERMORASTIC COVER PLATE TO MATCH
TI-E DEVIGE UNLESS OTFPERNISE SPECIPIED. COLOR OF THE DEVICE TO BE
SELECTED BY ARCHITECT. ALL BACK -TO -BACK DEVICES TO BE OFFSET
HORIZONTALLY 6' MINIMUM. UM. COMPLY WITH CURRENT ADA REQUIREMENTS.
3. THE EXACT LOCATION AND MOIMTIN6 I-IEI6HT OF ALL SNITCHES, OUTLET'S, ETC. ARE
TO BE CONFIRMED WITH ARCHITECTURAL ELEVATIONS AND OMER PRIOR TO
ROUGH -IN. IF LOCATIONS AND MOUNT1N6 HH6HT5 ARE NOT SHOWN, REST
LOCATIONS PRIOR TO ROUGH -IN. CONFIRM EQUIPMENT OUTLET LOCATION'S WITH
EGIJIPNIENT REGuiREfrans. COMPLY WITH ADA REQUIREMENTS.
4. S11ITCk1 AND DEVICES TO I5E AS SPECIFIED LEVITON, OR P # 5 AS AGCEPTAE3LE
ALTERNATES FOR SPECIFICATION GRADES.
5. NO 1TEM5 ARE TO BE SCALED OFF T}IE 13EGTRIGAL DRAWINCf ALL DIMENSIONS
SHOWN MST BE VERIFIED WITH THE OV+IER PRIOR TO ROU6I.1 -IN.
PANEL IE
208/12cW- PrI-4i
NOTES:
1. ALL FLUORESCENT LAMPS ARE TO BE ENERGY SAVING TYPE OF COLOR TEMPERATURE SPECIFIED AND BY THE SAME MANUFACTURER.
2. ALL FLUORESCENT BALLASTS ARE TO BE ENERGY SAVING ELECTRONIC TO MATCH LAMPS IN FIXTURE
3. ALL EXIT SIGNS TO HAVE RED LETTERS WITH 6" X 3/4" LETTERS AND 90 MINUTES OF BATTERY BACKUP.
4. ALL RECESSED DOWN UGHTS ARE TO HAVE INTEGRAL THERMAL PROTECTION.
5. CONFIRM ALL FIXTURE VOLTAGES WITH CIRCUITING ON PLAN.
6. MANUFACTURER TO VERIFY FIXTURE CATALOG NUMBER WITH THE DESCRIPTION OF THE FIXTURE AND CIRCUITING ON THE PLANS.
7. ALL BATTERY BACKUP FLUORESCENT FIXTURES SHALL HAVE BODINE B -50 (1350 LUMEN OUTPUT) AND CONTROL TWO (2) LAMPS PER FIXTUREE,
8. FIXTURE AND LAMPS FURNISHED BY OWNER AND INSTALLED BY ELECTRICAL CONTRACTOR. ELECTRICAL CONTRACTOR TO PROVIDE ALL MOUNTING
9. ELECTRICAL CONTRACTOR SHALL FURNISH 6 SPARE LAMPS OF EACH TYPE TO THE OWNER.
10. ALL FLUORESCENT LAMPS AND BALLASTS TO BE WATT MISER TYPE.
11. ALL FLUORESCENT LAMPS TO BE G.E. SP35 LAMPS UNLESS NOTED OTHERWISE, NO EXCEPTIONS.
12. HANG EMERGENCY LIGHTING FROM STRUCTURE IN STOCKROOM AREA.
MALL ELECTRICAL
ROOM "ZONE G'
f
MEN
RAM1LY
REFERENCE P0 WER PLAN
'G WITH 4 #1
° 2 -I/2
+ #8 6ND
FUSUG PI5T.4M10E • S3' -3
1/16" = 1'4P"
SEPARATE PERMIT
REQUIRED FOR:
Mechanical
L
Electrical
f Plumbing
[i Gas Piping
City of Tukwila
BUILDING DIVISION
NOTE: 2006 IBC — Sec. 1 006
Provide an average of one
footcandle illumination at the
floor along the entire egress
pathway and exit discharge
No change , ; _ - f
of WO T r• V... :.e _. .:) ai of
Tukwila bLu;k _ :,I. 1„ea.
Nom: Revisions wail; require a new plan submittal
and may include additional plan review flees.
PANEL 5,120/203V,
3PH-4W
15 KVA TRANSFORMER
480/120/203V, 51
PANE A, 2T1/480V,
3PH-4W
HOZ
ALL LJ6HTING FIXTURES AND
LAMP5 RM151-fED BY 01
AND INSTALLED BY
FLECTRIGAL CONTRACTOR
HARDWARE, ETC.
1-
L111/5
OEM
LT11/5
LT11/5
LT11/5
APPROVED P! ":µ . ".' 7'7.17.1riCAT1 IC
r T ry r r! !A.NQED, MODIFIED CR ALTERED
WITHOUT AUTHORIZATION FROM THE BULL
OTFIC!AL, ALI. WORK SHALL BE GONE IN
ACCORDANCE WITH THE APPROVED PLANS AND
IS l'J3:ECT TO FIELD INSPECTIONS
LTQ/5a
LTIII5
TYPICAL
LTI3 /ci
LTI3/4
LTI3/q
LTI3/q
L113/4
LTI3/q
LT13/q
SALM
13-3
STOCK
B-5
TRACK
B-T
TRACK
B-4
TRACK
5-11
CONTACTOR TO VERIFY EXACT CONFIGL RATION REQUIRED WITH
SPACE AVAILABLE.
CIRCUIT MSS ARE FOR REFERENCE ONLY. GOMRGTOR TO
PROVIDE LABELS AS DIRECTED BY OWNER
SBSGRIPT 'a' DENOTES THAT AN IJN NNLTCHED HOT LEG SHALL SE
BROUGHT TO THE FIXTURE. THIS Iht5WITCHBD LE6 SHALL BE ROUTED
ARCM, ALL LOCAL SNITCHING, CONTACTORS, EGT.
.i 2 ALL EXTERIOR LIGIffINS HAS pfd PROVIDED UNDER THE SHELL
CONTRACT AND 15 EXISTING.
7€:
S PACE \'"OVE CE!LINf S 15 UTILIZED
AS A i ;1. 1. N AIR PLE '9 t ALL
MATERI _5 ABOVE G1~ILIN65 SHALL
DE PURIM RAT-'!,
TO SNITCH
PANEL
LT15/4
SWITCH PANEL DETAIL
SC ALE: NONE
CODED NOTES:
LT11/5
- 1 - TO SNITCH
\PANEL
_DE 11
SEE SNITCH
DETAIL ON THIS SHEET
,p
LIGHTING FLOOR PLAN
LT13/1 . LTI3/1
1/4" = 1
ENE
LT8/3
LT5/5
LT8/3
L1133111
Public Works, Building Division
PERMIT NUMBER
ELo7 811
FILE PY
Nandi No.
Plan review approval 1s subject b anus and ornals.
Approval of construction documents does not authorize
the violation of any adopted code orb. Receipt
of approved Petri Copy and - , dj�9
/ ba men.*
r
Date:, r ��
Cfty of Tukwila
BUILDING DIVISION V
B-I THRU
TITBGLOGK I
B-I3 TH1R1J
Tit' CLOCK I
v LTI3/T v LTI3'/T I
LT4/I
II
II
II
1 1
1 LT4/1
II
I LT4/I
L114/3a
LT4/I :: *10 LTT5/3a
LT4/I
RICER T
DEC 2 8 2007
P -M CLNTEh
L113/13
(TYP. 3)
LTI3/13
(TYP. 3)
L113/13
(TYP, 3)
L113/13
(TYP. 3)
EX?JRES // - 2a -rte 1
GONTRAGTOR MUST VERIFY
ALL CLEARANCES AND
DIMENSIONS IN FIELD
FILE COPY
DALE
08- TT -0'T
rn
m
cz) co
rJ
H ~
E CO
_ N
VI
W
� Z �
�O r. �
Lel
tt)
Z rV
a CO
L./
as
18c)
•
EZ
f SSUE
SIMPER -11T
stride rrte SCUM CiakiTER
LIGHTING
FLOOR
PLAN
Dennis T Mitchell
Aug 10, 2001 - 14153'22
PANEL B
VOLTAGE! 208/120 MAINS'
PH & WIRES' 3P 4W AIC RATING'
BUSSING AMPS' 100 MOUNTING'
60/3 M.C,B,
10 KAIC
SURFACE
L❑CATI ❑N' STOCKROOM
FEEDER' 4 #4 + #8 GND - 1'C
KVA LOADS
LOAD DESCRIPTION
KVA
P
AMP
CCT
PH A
PH B
PH C
CCT
AMP
P
KVA
LOAD DESCRIPTI ❑N
DOWN LIGHTS
0,37
1
20
1
0.73
- --
- --
2
20
1
0.36
CASHWRAP IG RECEPTACLE
SALES LIGHTS
0.56
1
20
3
- --
0,86
- --
4
20
1
0.30
2 RECEPTACLES
STOCK LIGHTS
0.35
1
20
5
- --
- --
0.53
6
20
1
0.18
1 RECEPTACLE
TRACK LIGHTS (10')
0.20
1
20
7
0.65
- --
- --
8
20
1
0.45
SHOW WIND ❑W RECEPTACLE
TRACK LIGHTS (18')
0.40
1
20
9
- --
0,85
- --
10
20
1
0.45
SHOW WINDOW RECEPTACLE
TRACK LIGHTS (8')
0.25
1
20
11
- --
- --
0.43
12
20
1
0.18
DISPLAY RECEPTACLE
TRACK LIGHTS (16')
0.60
1
20
13
0.78
- --
- --
14
20
1
0.18
DISPLAY RECEPTACLE
SPARE
0.00
1
20
15
- --
0,36
- --
16
20
1
0,36
TELEPHONE BACKBOARD
GFI RECEPTACLE
0.18
1
20
17
- --
- --
0.38
18
20
1
0,20
FACP
SPARE
0.00
1
20
19
0,00
- --
- --
20
20
1
0.00
SPARE
SPARE
0.00
1
20
21
- --
1.00
- --
22
20
1
1.00
SIGN
SPARE
0.00
1
20
23
- --
- --
1.00
24
20
1
1.00
SIGN
SPACE
25
0.00
- --
---
26
20
1
0.00
SPARE
SPACE
27
---
0,00
---
28
SPACE
SPACE
29
-- --
- --
0.00
30
SPACE
CONNECTED AMPS' 21,01
2.16
3.07
2.34
CONNECTED KVA1 7.57
NOTES' PR ❑VIDE SOLID NEUTRAL BUS & GROUND BAR.
S = INDICATES SWITCH RATED CIRCUIT BREAKER
L = INDICATES LOCK -ON CIRCUIT BREAKER TOTAL DEMAND AMPS 37.23
PALL A
VOLTAGE! 480/277 MAINS:
PH & WIRES! 3P 4W AIC RATING!
BUSSING AMPS' 100 MOUNTING!
100/3 M.C.B.
18 KAIC
SURFACE
LOCATION' STOCKROOM
FEEDER! 4 #2 + #8 GND - 2 -1 /2'C
KVA LOADS
LOAD DESCRIPTION
KVA
P
AMP
CCT
PH A
PH B
PH C
CCT
AMP
P
KVA
LOAD DESCRIPTION
FPB-1
1,90
3
15
1
4,06
- --
- --
2
25
3
2.16
15KVA TRANSFORMER
PANEL 'B'
L90
3
- --
4.97
- --
4
3.07
1.90
5
- --
---
4.24
6
2,34
SPACE
7
0.00
---
- --
8
SPACE
SPACE
9
- --
0.00
- --
10
SPACE
SPACE
11
- --
- --
0.00
12
SPACE
SPACE
13
0.00
- --
- --
14
SPACE
SPACE
15
- --
0.00
- --
16
SPACE
SPACE
17
- --
- --
0.00
18
SPACE
CONNECTED AMPS' 15,96
4.06
4,97
4.24
CONNECTED KVA! 13,27
NOTES' PR ❑VIDE S ❑LID NEUTRAL BUS & GROUND BAR.
S = INDICATES SWITCH RATED CIRCUIT BREAKER
L = INDICATES LOCK-ON CIRCUIT BREAKER TOTAL DEMAND AMPS 22.99
TC1
TC1
TC4
TC4
TC4
TC1
MAIN DISTRIBUTION PANEL
LOADS
- GENERAL LIGHTING
NEC METHOD=
1,202 SQ. FT. X 3.0 VA /
ACTUAL LOAD=
- OUTSIDE SIGN CIRCUITS
2 X 1200 VA /EA. _
- TRACK LIGHTING
52 FEET X 75 VA /FT =
- SHOW WINDOW LIGHTING
10 FEET X 200 VA /FT
- HOT WATER HEATER
MINIMUM SZE SERVICE
LOIN
- RECEPTACLES AT 180 VA EACH
- HVAC LOAD (GREATER OF HEATING/COOLING)
HEATING = 0.0 KVA
COOLING = 5.7 KVA
- MISCELLANEOUS
- SUB TOTAL NON - CONTINUOUS LOADS
- SUB TOTAL CONTINUOUS LOADS
SERVICE VOLTAGE = 480
PHASE = 3
SQ. FT.
Total
Total Amps
v �
COMBINATION SPEAKER $ ADA
STROBE, ADJUSTABLE 15 cd TO
110 ad
ADA STROBE ONLY
VISUAL DEVICES SHALL SYNCHRONIZE
YI-E EVVR MORE THAN ONE ARE
VISIBLE FROM AMY LOCATION..
Lighting
Slgnage
Show Window Length
Track Length
Receptacles
Ac Units
Elec. Heat
Hot Water Htr.
Miscellaneous
3.6 KVA
1.3 KVA
SMOKE DETECTOR
ABOVE PANEL
AV
Connected
1.28
2,00
0.90
1.45
1.38
0.00
0.00
0.00
0,56
7.57
21.01
FACP
TO DEDICATED . p
20/1 WITH LOCK-ON ,
HANDLE S-IS
Demand
1.60
2,50
2.50
4.88
1,38
0,00
0.00
0.00
0,56
13.41
37.23
LOAD
FIRE ALARM WIRING DIAGRAM
SCALE: NONE
D.F. ; c LOAD
1.4 NEC 1.4
5.7 100% 5,7
0.6 100% 0.6
3,2 125% 4.0
2.4 125% 3,0
3.9 125% 4.9
2.0 125% 2,5
0,0 125% 0.0
D P
TOTAL =
WIRING LE4
AMPS = 26.5
D = DATA CIRCUIT AT#187-
SHIELDED, TWISTED PAIR
DH = DOOR HOLD CIRCUIT - 2 #I4
P = 24Vdc POPER 2 #I4
AV= VISUAL CIRCUIT 2 #I4
AUDIO CIRCUIT 2 Ma TSP
M
CM
- ADDIRESABLE
I I PULL STATION
J
7,6
14.4
22.0 KVA
REMOTE TEST
SWITCH BY M.G.
,- INTERLOCK TO
SHIJTDOPIN UNIT ON
ALARM
CONNECTION TO MALL
FIRE ALARM SYSTEM
ON PLAN
KTrgz
TC2
TC2
TC2
TC2
TC3
TC3
EXISTING TELE-METERING
SYSTEM BY LANDLORD
CALCULATED 1 AULT CURRENT -10$04
AMPS VERIFY WITH UTILITY.
ELECTRICAL CONTRACTOR SHALL VERIFY EXACT WIRING WITH
MANUFACTURER'S WIRING DIAGRAMS PRIOR TO INSTALLATION.
2, ALL DEVICES TO BE FIELD TESTED WITH MITI%
CERTIFICATION OF SYSTEM. PERFORM ALL TESTS IN 7I-E
PRESENCE OF THE A)THOWTY HAVING JURISDICTION.
3, PROVIDE CONNECTION TO REMOTE SUPERVISION A5 DIRECTED
FOR SAPERVISION OF SYSTEM IN GONFLIANCE WITH LOCAL
AUTHORITY AND OPENER PROVIDE ALL INTERFACE REWIRED
TO INITIATE REMOTE 5UP8"t1ISION. MONITORING SERVICE WILL
53E PAID FOR BY 11-E LANDLORD.
4. DUCT SMOKE DETECTORS ARE TO BE FURNISHED AND
INSTAU W BY MECHANICAL CONTRACTOR PERM PR.'S
INSTALLATION REQUIREMENTS AND NFPA 72E PROVIDE
MONITORING SYSTEM GONEJEGTION BY ELECTRICAL
CONTRACTOR
E.G. TO COORDINATE WITH MALI_
LANDLORD INSTALLATION OF METER 4 100
AM' 3 POLE MAIN GB., E.G. SHALL INGLIUDE
COST OF LANDLORDS EL. TO INSTALL
METER 4 GB. IN EXISTING SWITGEROOM.
5. INDICATION DEVICE SHALL BE COMBINATION HORN / STROBE,
FIELD ADJUSTABLE, 15 cd T0110 cd. ALL STROBES SHALL
SYNNGHRONIZE.
6. FIRE ALARM PANE_ SHALL 13E SOLID STATE, ADDRESSABLE,
ANALOG PANS WITH CLASS B' BELL CIRCUIT, ALARM AND
TROUBLE INDICATION BY DEVICE:, 24 HOUR 13A BACKUP
AND PANNE STATUS INDICATION LIGHTS
7. SYSTEM SHALL BE .SUPPLIED BY ONE MFR AND BEM': SIMPLEX
TO MATCH MALI- CRITERIA - 206 -2:1I -1400.
S. THE ENTIRE SYSTEM 5HALL CONEFLY WITH ALL APPLICABLE
CODES AND LISTINGS, INCLUDING THE FNFPA 72, UL, FM AND THE
STATE AND LOCAL FIRE MARSHALL.
q. FIRE ALARM SYSTEM MANUFACTURER SHALL PROVIDE ALL
SA3MITTAL5 REWIRED BY LOCAL OFFICIALS FOR PERMIT
INCLUDING, BUT NOT UMITED T0, 3A I i t KY GALCULATIONS,
VOLTAGE DROP CALCULATIONS, GUT SFEETS, DRAWIN 5 ETC.
PAY ALL PERMIT FEES, ETG.
#2+#8 GNP - 21/2'G,
EXISTING CONDUIT STABBED
INTO TENANT SPACE. EG. TO
EXTEND CONDUIT TO PANE.
INSTALL FEEDER WIRE BACK
TO SERVICE CIRCUIT BREAM.
FAULT CURRENT
- U),642 AMPS
NEN 100/3 MAIN
CIRCUIT BREAKER.
L
LANDLORDS MAIN SWITCHBOARD
PANEL lE IN LANDLORDS ELECTRICAL
ROOM
0
O
100/3
MGB
PAN13
'A'
Lighting
Slgnage
Show Window Length
Track Length
Receptacles
Ac Units
Elec. Heat
Hot Water Htr.
Miscellaneous
Total
Total Amps
3 #I0 - 3/4'G
FAULT CURRENT -
619 AMPS
v `
0
6013
MCB
PANEL
t3'
ONE LINE POWER DIAGRAM
SCALE NONE
Connected
1.28
2.00
0.90
1.45
1.38
5.70
0.00
0,00
0.56
13.27
15.96
IEKVA TRANSFORMER 480V
TO 120/2013V-3PH -4W
473 GEV
4#4+ #a GND -
I'G
FAULT CURRENT - 6a2
AMP5
Demand
1.60
2.50
2,50
4.88
1.38
5,70
0.00
0.00
0.56
19.11
22.99
PANEL 5,120/203V,
3P14-4P1
15 KVA TRAM 1188
480A20/208V, 31
PANEL A, 277/480V,
3F14-4N
MALL FIRE ALARM
5 V:L/ TIE: IN .UNCTION BOX
EXISTING SERVICE CONDUITS
STUD INTO SPACE
3/4 TEEEPEONE CONDUIT
2' x4'x3/4"
BACKBOARD
SEE WERENCE POWER
PLAN ON E -I
0
POWER FLOOR PLAN
1/4" = 1
2211E21KEffl _
FAN POWERED BOX, 5 KIN - 480V - 3 PHASE HEATER. + 2TIV - I PHASE MOTOR UNIT PROVIDED WITH
DISCONIEGT.
�2 PROVIDE J-BOX ABOVE CEILING FOR SPEAKER WIRING, SIZED AS REWIRED. SPEAKS PROVIDED
AND INSTALLED BY OYINER, TYPICAL SEE ARLHITEGTURAL CEILING PLAN FOR EXACT LOCATION
• PROVIDE TONE OUTLET, CONDUIT AND PHONE LINE TO TELEPHONE BACKBOARD. SIZE AS REQUIRED
BY TH.EPI.ONE EQUIPMENT SUPPLIER - 3/4' MINIMUM.
O PROVIDE TELEPHONE JACK AND GAT 5 JACK
O TEE: EXISTING FIRE ALARM SYSTEM HAS BEEN PROVIDED UNDER THE LANDLORD MALL WORK I1-E
ACTIVATION OF ANY FULL STATION OR DUCT SMOKE DETECTOR WITHIN THIS TENANT SPACE SHALL 13E
RECOGNIZED A5 A FIRE ALARM CONDITION BY THE EXISTING MALL FIRE ALARM CONTROL PANEL. TEE
ACTIVATION OF ANY FULL STATION, SMOKE DETEGTOR, HEAT DETECTOR, WATER MAN SWITCH OR
ERRVISORY SWITCH ESBE IN THE WALL SHALL SOUND 11-E APPROPRIATE CODE IN THIS TENANT
SPACE AND SHUT DONN THE EXISTING ROOF TOP AG UNIT. RESETTING OF THE SYSTEM SHALL BE
POSSIBLE ONLY FROM THE FIRE ALARM CONTROL PANE..
® ALL DEVICES TO BE LOCATED WITHIN CABINET. COORDINATE WITH OPENER. PRIOR TO INSTALLATION.
O ELECTRONIC GASH REGISTER POYNER SYSTEM. THE CIRCUITS U5ED TO POYER 1 ELEGTP.OtNIG GASH
REGISTERS SHALL NOT BE USED FOR my OTHER. PURPOSES. THE CIRCUITS SHALL NOT SHARE 11-E
N YERAL OR GROUND WITH 071413Z EQUIPMENT. SEPARATE POWER, N I3JTRAL AND ISOLATED GROUND
11IR MINIM SIZE #12 AIMS, SHALL BE RUN TO THE CIRCUIT BREAKER PANELEOARD WHERE GROUND
WIRE SHALL BE TIED TO THE GROUND TERMINAL ISOLATED FROM NEUTRAL. DO NOT USE TEE CONDUIT
FOR GROUNDING AS THIS 15 NOT ADEQUATE AT HIGH EL t4GIE S. THE CIRCUITS FOR THE ELECTRONIC
GASH RESISTERS SHALL BE RUN IN SEPARATE CONDUIT. GASH REGISTER OUTLETS SHALL BE HUBBELL
NO. 16 62, OR APPROVED EQUAL THH5 SYSTEM 15 REQUIRED BY THE TENANT.
• PROVIDE SAFETY TYPE RECEPTACLE LEVITON GRI55 -6 MOUNTED HORIZONTALLY AT I6' AFT..
O SHOW WINDOW REGB'TAGLE FLUSH MOLD IN CEILING ABOVE WINDOW.
10 GOVERPLATES FOR ALL DEVICES IN SALES AREA SHALL BE PAINTED TO MATCH ADJACENT WALL.
SURFACES. DEVICE COLORS SHALL BE AS DIRECTED BY 01^fNER.
11 PROVIDE JUNCTION BOX AND ALL REWIRED CONNECTIONS TO NEW STOREFRONT SIGNS. COORDINATE
REQUIREMENTS WITH SIGN MANUFACTURER MANUFACTURER SHALL PROVIDE DISCONNECT SNITCHES.
ROUTE SIGNAGE CIRCUITS THROUGH TIMEGLOCK LOCATED AT PANEL.
12 PROVIDE SAFETY TYPE RECEPTACLE LEVITON GRI55 -6 MOUNTED AT BASE OF 5P0/114100H.
1 PROVIDE GAT 5 DATA LINE TO TELEPHONE BACKBOARD.
I t " '1;' �ZI -
I' 3-I6 541
j
A-I, 3
45 cd
5-16
277/460V, 31=H
6b FAA FP
82 MEGA
15.0 MOCP
REMOTE
SWITCH
WP
GFI
n ttiVa-6
45 cd
01
1)1
1:111
IL J
•
0 1 ,I ,
0
5-2
1
1
1
1
0
0 Iw�I'
m ^ 0��1 O
0
1Ik O AT 66'
IND
B-4
1 1 I
l8'
1
1
1
1
45
Tt
B-10 THRU
TIt4EGLOGK
B-8
THRU
11 :..
8-1211 J
TIMi£G
'ANAL V
RECEIVED
DEC 2 8 2007
PE ivil i CENTECENTER
Eun�- 8 I )
l 'I J
LOCK 2 m
111111 O
B-22, 24 THRIJ
nurammelp
ri TIMECLOGK 3
1
lExPIREs /I --j
CONTRACTOR MUST VERIFY
ALL CLEARANCES AND
DIMENSIONS IN FIELD
DATE
08 - 17 -07
E2
ISSUE
S
stride rite 12CUT14 c MTEIR
POWERFLOOJ1
PLAN
4
-
s
F
c
Project Info
Project Address Stride Rite South Center Mall Space x1300
Date 8/6/2007
633 South Center Mall
For Building Department Use
Tukwila, WA
Applicant Name: Edward P. McHenry
ApplicantAddress: 25001 Emery nd, Warensville Hts., Ohio 44128
Applicant Phone: 216- 292 -4696
Project Description
LIGHTING CONTROLS (Section 1513)
-' New Building II Addition ❑ Alteration
II Plans Included
Refer to WSEC Section 1513 for controls and commissioning requirements.
..:......:
Lighting= .Permit 'Pl`ans : •: LTG - CHK
2004 Washington State Nonresidential Energy Code Compliance Forms Revised May 2005
Project Address Stride Rite South Center Mali space 01300
Date 8/6/2007
The following information is necessary to check a lighting permit application for compliance with the lighting requirements in the
2004 Washington State Nonresidential Energy Code.
Applicability
(yes, no, n.a)
Code
Section
Component
Information Required
Location
on Plans
Building Department
Notes
LIGHTING CONTROLS (Section 1513)
yes
1513.1
Local control /access
Schedule with type, indicate locations
El
Strip Fluorescent
yes
1513.2
Area controls
Maximum limit per switch
El
0.2 W /ft
no
1513.3
Daylight zone control
Schedule with type and features, indicate locations
0.25 W /ft
no
Bldg. (by Perim)'
vertical glazing
Indicate vertical glazing on plans
no
overhead glazing
Indicate overhead glazing an plans
yes
1513.4
Display /exhit /special
Indicate separate controls
El
1 51 3.5
Exterior shut off
Schedule with type and features, indicate location
w
(a) timer w /backup
Indicate location
no
(b) photocell
Indicate location
1513.6
Inter, auto shut -off
Indicate location
no
1C13 6.1
(it) occup. s■^nsors
Schedule with type and locations
ye S
1513.6,2
(b) auto. switches
Schedule with type and features (back -up, override capability);
Indicate size of zone on plans
El
1513.7
Commissioning
Indicate requirements for lighting controls commissioning
n.a_
Lighting Sum corm
Completed and attached.
Schedule with fixture types,
lamps, ballasts, watts per fixture
n a
1437
Etec motor t�lticiency
MEOW -MOT or Equipment Schedule with hp, rpm, efficiency
Location
(floor /room no.)
Occupancy Description
Allowed
Watts per ft
Area in ft
Allowed x Area
Retail
Down Lights
Retail
1.50
900.0
1350.0
2x2 parabolic
7
80.0
560.0
Retail
Strip Fluorescent
7
58.0
406.0
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts
x.337.0
0.2 W /ft
•* From Table 15 -1 (over) - document all exceptions on form LTG-LPA Total Allowed Watts
1350.0
Location
(floor /room no.)
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Retail
Down Lights
7
53.0
371.0
Retail
2x2 parabolic
7
80.0
560.0
Retail
Strip Fluorescent
7
58.0
406.0
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts
x.337.0
Location
Description
Allowed Watts
per ft or per If
Area in ft
(or If for perimeter)
Allowed Watts
x ft (or x If)
Covered Parking
(standard paint)
N/A
0.2 W /fi
Covered Parking
(reflective paint)
N/A
0.3 W /ft
Open Parking
N/A
0.2 W /ft
Outdoor Areas
N/A
0.2 W /ft
Bldg. (by facade)'
N/A
0.25 W /ft
Bldg. (by Perim)'
N/A
7.5 W/If
t Choose either the facade area or the perimeter method, but not both) Total Allowed Watts
Location
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
N/A
Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts
Lighting Summary
LTG -SUM
2004 Washington Stale Nonresidential Energy Code Compliance Forrns
Compliance Option
Alteration Exceptions
(check appropriate box - sec. 1132.3)
No changes are being made to the lighting
❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed.
Maximum Allowed Lighting Wattage (Interior)
Proposed Lighting Wattage (Interior)
2004 Washington State Nonresidential Energy Code Compliance Form
0 Prescriptive Q Lighting Power Allowance 0 Systems Analysis
(See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.)
Revised Ma 2005
Notes:
1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only,
the default table in the NREC Technical Reference Manual may also be used
2. Include exit lights unless less than 5 watts per fixture.
3. List all fixtures. For exempt lighting, not exception and leave Watts /Fixture blank.
Maximum Allowed Lighting Wattage (Exterior)
...,.. ..., , ..... -.. ,..�...��. �..�.. �.�pu� r.a.,a vi �in�u�cO �rv�u� ��a�u -�rvn cu uGttAAW Vltly,
Proposed Lighting Wattage (Exterior) the default table in the NREC Technical Reference Manual may also be used.
2004 Washington State Nonresidential Energy Code Compliance Form
If
no is circled for any question, provide explanation:
Public Works, Building Division
PERMIT NUMBER
INCOMPLETE
LTR #
E L07- 811
C VE
JAN 2 8 2008
PE iMiT CENTER
rEXPIRES 8/31/ O
CONTRACTOR MUST VERIFY
ALL GLEARANGES ANP
DIMENSIONS IN FIELD
FILE COPY
DATE
08-11-07
eir)
t
rzl O
m
M �
U oh I
▪ 4
kr) co t
W
c 7, co
Lei
C
IJ
W L A
0 a
O • VA
- Qn F
LSD Q co C
E3
ISSUE
BID/PERMIT
etrtdv ra. SCUM CENTER
LIGHTING
FLOOR
PLAN
GBNEIRAL INFORMATION
SFEGIFIGATIONS
A. GENERAL.
I. CONFORM TO ALL GENERAL AND SPECIAL GcNDmoNS OF CONTRACT AS
SPECIFIED BY ARLHHTEGT, TENANT AND OWNER
2. SPECIFICATIONS ARE APPLICABLE TO ALL CONTRACTORS AND
SUBCONTRACTOR5 FOR MECHANICAL AND ELECTRICAL SYSTEMS.
3. CONTRACTOR SHALL COMPLY WITH LANDLORDS STANDARDS, FACILITY
SFEGIFIGATIONS, RUTS AND REGULATIONS. ALL LANDLORD
CRITERIA SHALL EE COMPLIED WITH AND INCLUDED IN T1-115 BID.
CHECK OTHER PLANS AND SPEGIFIGAT10145 AND FULLY COORDINATE
WITH OTHER TRADES AND ARCHITECTS REQUITTTS.
4. VISIT SITE, CHECK FACILITIES AND CONDITIONS, AND VERIFY ALL
UTILITY COMPANY RF JIREME4T5 AND COMMOTION POINTS IN FIELD
PRIOR TO STARTING WORK. TAKE ALL ITEMS INTO CONSIDERATION
IN BID.
5. SYSTEMS ARE TO BE COMPLETE AND WORKABLE IN ALL RESPECTS,
PLACED IN OPERATION AND PROPERLY ADJUSTED.
6. EACH CONTRACTOR SHALL PROVIDE FOR HIS OWN CLEAN-UP, REMOVAL
MD LEGAL DISPOSAL OF ALL RUBBISH DAILY.
1. ARRANGE FOR AND OBTAIN LANDLORD'S AND INSURANCE
REPRESENTATIVE'S PERMISSION FOR ANY SERVICE 51
SFL tPOWJS MUST BE PERFORMED WITHOUT DISRUFflQN TO FACILITY
OPERATIONS, AS SCHEMED WITH THE LANDLORDS REPRESENTATIVE
INCLUDE ANY FREMIUM TIME REQUIRED 114 5117.
8. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION
MEANS, METHODS, SEGIIENCE OF CONSTRUCTION MD TI-E SAFETY OF
WORKMEN. COMPLY WITH ALL OSHA REGULATIONS.
q. NO PIPING, DUCTWORK CONTROLS, ETC., SMALL BE INSTALLED OR
ROUTED ABOVE ELECTRICAL PANELS AND EJIPMBNT.
10. THE MECHANICAL AND ELECTRICAL CONTRACTORS SMALL COORDINATE
THE ELECTRICAL CHARACTERISTICS OF ALL MECHANICAL EQUIPMENT
PRIOR TO ORDERING OF EQUIPMENT. NO ADDITIONAL PAYMENT WILL
BE MADE FOR LACK OF CONTRACTOR COORDINATION OF ELECTRICAL
CHARACTERISTICS.
II. CEILING FLEW 15 UTILIZED AS A RETURN AIR PLEfLM. ONLY
PLENUM RATED MATERIALS WILL BE PERMITTED.
12. ALL MECHANICAL AND E ECTRIGAL SYSTEM COMPONENTS SHALL BE
ROUTED TIGHT TO UNDERSIDE OF STRUCTURE AND THROUGH JOISTS OR
TRUSSES WHERE POSSIBLE. COORDINATE INSTALLATION TO PREEERVE
HEADROOM, EGIUIPM3NT ACCESS, AND ARCHITECTURAL CLEARANCE FOR
FINISHES, INCLUDING CEILING HEIGHTS. COORDINATE WITH ALL
OTFER TRADES AND D0 NOT CONFLICT ROTH THE ,ARCHITECTURAL
REQUIREMENTS FOR THE FINISHED CONSTRUCTION. PROVIDE: OFFSETS
HERE REGdIREP TO COORDINATE WITH OTHER TRADES.
13. REFER TO ARCHITECTURAL REFLECTED CEILING FLANS FOR LOCATIONS
OF ALL GRILLES AND DID.
B. CODES, STANDARDS AND REGUATIONS
I. CONFORM TO ALL APPLICABLE CODES, GOVERNMENT REC CATIONS,
UTILITY COMPANY REGDIRIENTS, AND NATIONAL ELECTRICAL CODE.
2. OBTAIN PERMITS AND PAY ALL FEES. ARRANGE FOR ALL REQUIRED
INSPECTIONS AND APPROVALS.
C. RELATED WORK SPECIFIED
I. OFENNGS AND CHASE, WHEN SHOWN ON ARCHITECTURAL DRAWING .
17. DRAWINGS
I. THE SYSTEMS AS SHOP%' ON THE CONTTRACT DRAWNGS ARE
DIAGRAMMATIC.
2. 11-E INTENT 15 FOR COMPLETE AND WORKABLE SYSTEMS. THE
DRAWINGS AND THESE NOTES ARE TO BE USED TOGETHER AS A BASIS
OF 5HO11146 AND /OR DESCRIBING THE SYSTEM REQUIREMENTS FOR THE
FACILITY.
3. VERIFY ALL PIMEMSION5 AND CLEARANCES BY FIELD MEASUREENT
AND CHECK FOR INTERF E5 PRIOR TO STARTING WORK
E. BASE EGVIPMENT AND MATERIALS ANP S& S117UTIONS
I. ALL EOIJIPMENT AND MATERIALS SHALL BE FEESN, FREE= OF DEFECTS
ARID UL. LABaE D.
2. SUBMIT 5140P DRAWINGS FOR ALL E GUIPMIE3NT, FIXTURES, ETC.,
INGLIDING ALL ACCESSORIES TO BE FURNISHED. BASE B117
MAFIJFACTURERS AND MODELS ARE INCLUDED IN SPECIFICATIONS OR
LISTED N SCHEDULE ON DRAPING. ANY Cill-TER MANJFAG1URER OR
MODEL 15 A SU135TITUTIOHL
3. SUBSTITUTIONS ARE SUB.EGT TO THE APPROVAL OF THE OWNER AND
SHALL BE LISTED ON TIE FORM OF PROPOSAL FOR THE OPIER.5
CONSIDERATION PRIOR TO CONTRACT AWARD. IF SUBSTITUTION 15
SUBMITTED, IT IS THE CONTRACTOR'S RESPONSIBILITY TO EVALUATE
IT AND CERTIFY THAT THE SUBSTITUTION 15 EQUIVALENT IN ALL
RE5FEGT5 TO Tl-IE BASE SPEGIFIGATIONS.
4. IF 5155T1TUTONS ARE APPROVED, No-rip!' ALL oTl DER CONTRACTORS,
SUBCONTRACTORS OR TRADES AFFEGTED BY SUBSTITUTION AND FULLY
COORDINATE AM' COSTS RESULTING FROM SUBSTITUTION, PS TH R
BY CONTRACTOR OR OTHERS, SHALL BE RESP01451131LITY OF AND PAID
FOR BY SUBSTITUTING CONTRACTOR
5. ALL EGUIFIRENT SHALL BE INSTALLS) IN 9 LL ACCORDANCE WITH THE
FMNJFAGTURERS INSTALLATION INSTRUCTIONS. IT 15 THIS
CONTRACTORS RESPONSIBILITY TO CHECK MD CONFORM TO THESE
RBGUIRBFENTS PRIOR TO STARTING ADM
F. GHEGK, TEST, 5TART, ADJUST, BALANCE AND INSTRRUGTIONS
I. AFTER INSTALLATION, CHECK ALL EQUIPMENT, AND PERFORM START
UP IN ACCORDANCE 14IT14 TI-E MANFAGTURER'S INSTIRIJGTIOMS.
2. ALL PIPING SHALL BE TESTES AND FREE= OF LEAKS.
3. BALANCE All SYSTEMS, CALIBRATE CONTROLS, CHECK FOR PROPER
OPERATING SEQUENCE UNDER AU- CONDITIONS, AND MAKE ALL
NECESSARY ADJ15h1ITS.
4. ALL WIRING SHALL BE HILLY TESTED AND MADE FREE OF GROUNDS
AND SHORT CIRCUITS.
5. INSTRUCT OWNER IN OPERATION OF SYSTEMS AND S1E3MIT OPERATING
AND MAINTEIANGE MANUAL ON ALL EQUIPMENT AND SYSTEMS.
6. PROVIDE ENGRAVED LABELS AND IDENTIFICATION TAGS FOR ALL
PIPING SYSTEMS, VALVES AND EQUIPMENT.
7. PROVIDE TYPE=D PANEL DIRECTORIES AND ENGRAVE? LABELS FOR ALL
PADS AND EQIJIPMEtf.
G. CUTTING, PATCHING AND DRILLING
I. ALL GUTTING AND CHASING of THE BUILDING CONSTRUCTION
RSGIJIREC FOR THIS WORK SHALL BE BY 11115 CONTRACTOR UNLE55
SHOWN ON ARCHITECTURAL DRAWINGS AND CONFIRMED AS TO SIZE AND
LOCATION PROR TO NEW CONSTRUCTION. GUTTING SHALL BE IN A
FEAT AND WORKMANLIKE MANNER
2. NEATLY SAW CUT ALL EREGTANGUL.AR OPENINGS, SET SLAVE THROUGH
OPENING, AND FINISH PATCH OR PROVIDE TRIM FLANGE AROUND
OPE]NNE
3. CORE DRILL AND SLEEVE ALL ROUND OPBNIN55.
4. DO Nor CUT ANY SWIJC.1 RAL COMPONENTS WITHOUT ARCHITECTS
APPFROVAL.
5. PATCH MD FINISH TO MATCH ADJACENT AREAS THAT HAVE BEEN CUT,
DAMAGED OR MODIFIED TO INSTALL EQUIPMENT FOR 1145 PROJECT.
6. FIRE STOP ALL PENETRATIONS OF FIRE RATED CONSTRUCTION IN A
CODE APPROVED MANNER, USING U_ LISTED FIRE RATED MATERIALS.
7. ALL CONTRACTORS SHALL CONFIRM WITH OWNER PRIOR TO BID,
- nye AVAILABLE FOR NOISE PRODUCING WORK SUCH AS CUTTING AND
CORE DRILLING OF FLOORS, WALLS, EEG., AS WELL AS TIMES FOR
WORK WHICH REQUIRE ACCESS INTO ADJOINING AREAS. INCLUDE ANY
PREMIUM TIME REQUIRED IN BID.
H WARRANTY
I. FULLY WIARRRANT ALL MATERIALS, EQUIPMENT AND SHIP FOR
ONE (I) YEAR FROM DATE OF ACCEPTANCE
2. EXTEND ALL MANJFAGTURER S WARRANTIES TO OWNER.
3. REPAIR OR REPLACE WITHOUT GORGE TO 11-E OWNER ALL ITEMS
FOIAm DEFECTIVE DURING 11-E WARRANTY PERIOD.
MECHANICAL SYSTEMS
FIRE PROTECTION SPRINKLER SYSTEM
A SCOPE
I. FURNISH ALL LABOR, MATERIALS AND E QUIPHNE T AS REQUIRED TO
INSTALL COMPLETE FIRE PROTECTION SY5TI34 FOR PROJECT.
2. SPRINKLER WORK FOR PROJECT ESSENTIALLY CONSISTS OF THE
FOLLOHING:
A. EXTEND FIRE PROTECTION SYSTEM FOR TENANT SPACE FROM
EASING FIRE PROTECTION Sr51E34, CAPER STUB OUTS BY
LANDLORD.
B. FIRE PROTECTION SYSTEM FOR ALL AREAS OF THE PROJECT.
G. PREPARE SUBMITTAL DRAWING AND HYDRAULIG CALCULATIONS
IN ACCORDANCE WITH OWNERS INSURANCE COMPANY, BUILDING
DEPARTMENT, AND LOCAL FIRE AUTHORITY'S RE DIRE 134T5 AND
SUBMIT TO LANDLORD AND LOCAL AUTHORITY HAVUNG
JURISDICTION FOR APPROVAL.
17. FLUSH AND CONDUCT FRESEXRE TEST OF COMPLETED 5YST94 IN
ACCORDANCE WITH NEPA AND A)11- TIES HAVING
..U2150107ION.
E OTHER ITEMS INDICATED ON DRAY'1NGS OR REQUIRED FOR
COMPLETE INSTALLATION.
B. DESIGN BASIS
I. DESIGN BASIS FOR SYSTEM SHALL BE FIER ALL AFPLJGABLE RHEA
STANDARDS, INGLE DINS, E3UT NOT UNITED TO, BULLETINS 13 AND
30, BUILDING CODE, INSURANCE UNDERI RITER, AND FIRE MARSHAL
R.EQUIRBMEITS. 5Y5T134 SHALL SE A HKDRAULIGALLY DESIGNED
SYSTEM.
G. DRAWIN65 AND CALCULATIONS
I. CONTRACTOR SHALL PREPARE SUBMITTAL DRAWING AND HYDRAULIC
CALCULATIONS FOR SPACE IN ACCORDANCE WITH OWNER'S INSURANCE
COMPANY AND BUILDING DEPARTMENT REQUIREMENTS.
2. CONTRACTOR SHALL OBTAIN FLOW TEST DATA ON CITY WATER MAIN
AND SUBMIT DMA WITH CALCULATIONS. PERFORM FLOW TEST IF
ACCURATE REGENT DATA 15 NOT AVAILABLE
3. CONTRACTOR MP DESIGNER SHALL BE STATE CERTIFIED.
4. CONTRACTOR SHALL INSTALL ALL SPRINKLER PIPING AS HIGH AS
POSSIBLE, TIGHT TO UNDERSIDE OF STRUCTURE, AND THROUGH
JOISTS OR LASSES WHERE POSSIBLE WITH DRAINS AND OFFSETS
BELOW BEAMS. SPRINKLE'. CONTRACTOR SHALL COORDINATE
SPRINKLER SYSTEM WITH DUCTWORK AND LIGHTS. ALL COSTS
ASSOCIATED MTH RAISING SPRINKLER PIPING *ERE 11-E
ARCHITECTURAL DESIGN CANNOT BE ACCOMPLISHED SHALL BE THE
RE OF THE SPRINKLER CONTRACTOR
17. PIPING
1. ALL PIPING SHALL BE INSTALLED IN ACCORDANCE HIM NEPA
REQUIREMENTS AND FM APPROVED.
2. FIRE PROTECTION PIPING SHALL BE AS FOLLOWS:
A INSIDE BUILDING - PIPE AND TUBING SHALL BE 5TE3_ OR
COFFER IN ACCORDANCE WITH THE LATEST ACCEPTED EDITION
OF NFPA -I3.
B. PIPING SHALL MATCH EXISTING BUILDING STANDARDS.
G. CONTRACTOR SHALL ARRANT FOR SHUTDOWN OF EXISTING
SYSTEM WITH LANDLORD, OWNER AND INSURANCE INDEIRWIRMER.
D. FLUSH All PIPING UPON COMPLETION OF PROJECT AND TEST
PER NEPA 13.
E. PLAS11G PIPING 15 NOT APPROVED.
E. SPRINKLE. HEADS
I. SPRINKLER HEADS SHALL 13E 1/2' ORIFICE, K =5.6, 165 DEGREES F,
UL LISTED, AND SHALL MATCH EXISTING BUILDING STANDARDS.
2. SPRINKLER HEADS SHALL BE AS FOLLOWS:
A. AREAS WITH EXPOSED STRUCTURE
I. UPRIGHT - ROUGH BRASS SPRINKLER READ.
5. AREAS WITH CEILINGS
I. RICH SPRINKLER HEAD - FLUSH SPRINKLER READ WITH
OFF -114ITE CEILING DISC PER LANDLORD REQUIREMENTS.
3. INSTALL HIGHER T13MP'ERATURE SPRINKLER HEAPS II-ERE REQUIRED BY
CODE OR APPLIGATION AND QUICK RESPONSE HEADS IN LIGHT HAZARD
OCCUPANCIES.
4. SUBMIT SAMPL E:5 OF SPRINKLER HEADS TO ARCHITECT FRMOR TO
FABRICATION OF ANY PIPING.
5. SPRiNCLEtR READS SHALL BE CENTERED IN THE CEILING GRID IN
BOTH DIRECTIONS.
F. VALVES
1. INSTALL ALL VALVES REQUIRED BY FFPA WHICH ARE 'ILL' LISTED
AND FM APPROVED.
2. ALL 5141If -ORE VALVES SHALL I5E PITTED WITH TAMPER SWITCHES BY
FIRE PROTECTION CONTRACTOR ANP WIRED BY ELECTRICAL
CONTRACTOR,
HEATING, VENTILATING AND AIR GONDI11ONAN6
A SCOPE
I. FURNISH ALL EQUIPMENT, MATERIALS, LABOR, TOOLS, ETC., FoR
T}E COMPLETE WAG SYSTEM. INSTALL COMPLETE AND FLARE IN
OPERATION.
2. H1/AC SYSTEM ESSENTIALLY CONSISTS OF THE FOLLOWING:
A. FAN POWERED VAV TERMINAL UNIT.
B. DUCTWORK, GRILLES, DIFR15ERS AND OTHER AGGE55ORIES.
G. INSULATION OF HVAC 1713ff5.
17. BALANCING, TE5TRN6 AND START LAP.
E. TEMPERATURE CONTROL SYSTEM.
F. OTHER ITEMS INDIGATE7 ON DRAWINGS OR REQUIRED FOR
COMPLETE INSTALLATION.
B. DUCTWORK
1. FABRICATE AND ERECT ALL DUCTWORK TO ASHPAE AND SMAGNA
STANDARDS FROM NO. I GALVANIZED ST®- COMPLY WITH SMAGNA
STANDARD5, AND NFPA BULLETIN q0A REQUIREMENTS
2. DUCTWORK DOWNSTREAM OF VAV TERMINALS SHALL BE SMACNA LOW
PRESSURE CONSTRUCTION 2' STATIC PRESSURE RATING WITH SEAL
GLASS B SEAMS AND JOINTS.
3. DUCTWORK UPSTREAM OF VAV TERMINALS SMALL 8 SMAGNA MEDIUM
� CONSTRUCTION 3 STATIC PRESSURE RATING WITH SEAL
CLASS A SEAMS AND JOINTS SEALED WITH EC -800 COMEPOW OR
SIMILAR ALL FITTINGS SHALL BE CONICAL TYPE
4. ALL DUCTWORK SHALL BE INSTALLED TIGHT TO UNDER5IDE OF STEEL
OR TO HEIGHT AS INDIGATED ON FLANS.
FLEXIBLE DUCTS SHALL BE IFEDEPENDENTLY SUPPORTED HROM 1iE
STRUCTURE AND CONNECTED NTH FETAL DRAW BANDS. FLEXIBLE
DUCTS SHALL BE UNITED TO 60' STRAIGHT LENGTHS ANP ARE NOT
PERMITTED IN ROOMS WITHOUT CEILINGS. FLEXIBLE = DUCTS SHALL
BE ATCO ME ER TYPE 010, I I/2' INSULATION AND RATED AT IO"
W.G. FOR SIZES 11 -ROUGH 12 UL. LISTED, AND MEET 25/50
FLAME AND SMOKE TEST. NO INTERIOR COLOR OTFE R THAN BLACK 15
PERMITTED FOR FLEXIBLE DUCTS. EQUIVALENT BY VALUFLEX, FLEX -
AIRE, FLEXIBLE* TEGf9JOLOGIES, TIER4AFLEX OR GBNREX
6. INCLUDE ALL - TURNING VANES, MANUAL DAMPERS, FLEXIBLE
GOFENEGTORS, GRILLES AND DIES, ACOUSTIC LINING, AND
OTT-fH. SHEET METAL ACCESSORIES FOR 11 PROJECT. VOLUME
DAMPERS TO BE OF OPPOSED BLADE CONSTRUCTION WITH LOCKING
QUADRANTS. PROVIDE VOLUME DAMiFERS A7 SUPPLY AIR RAr0UT5 TO
ALL GEILIN6 DIFFUSE S.
1. ALL BRANCH CONNECTION FITTINGS IN RECTANGULAR DUCTWORK SHALL
BE 45 DEGREE TRANSITION TYPE, CONICAL FITTINGS OR SPiN -IN
FITTINGS NTH INTEGRAL AIR SCOOPS. EU1T FITTIN65 ARE NOT
ACCEPTABLE
8. ACOUSTIC LINE ALL RECTANGULAR DUCTS INDICATED ON DRAWIN65
KITH MINIMUM ONE 0) IFY.,H THICK NON- FLAKMS, GOATEE NWIUM
DENSITY LINER APPLY TO MANUFACTURE RS RE=COMMENDATIONS.
DUCT DIMENSIONS ARE OUTSIDE DIMER51ON5, AND NOME ACOUSTIC
LINING.
G. INSULATION
L 11-E FOLLOWING DUCT SYSTEM SHALL BE IESILATEED INHERE CONGEALED
ABOVE CEILINGS KITH I -1/2' THICK FOIL FACED REINFORCED KRAFT
JACKET FIBERGLASS DUCT WRAP:
A. UNLINED SUPPLY AIR DUCTS, INCLUDING BACKS OF CEILING
DIFFUSERS
2. INSULATION SHALL BE FULLY SECURE? TO DUCTWORK LAP E TAPE
SEAMS AND SECURE TIGHTLY TO DUCTS HiTH WIRE OR STICK PINS.
3. ALL INSULATION TO BE APPLIED IN FUL ACCORDANCE WITH THE
MANUFAG1URE RS RECOMMENDATIONS. ALL INSULATION SHALL COMPLY
WITH 25/50 FLAME AND SMOKE HAZARD RATN65 PIE. ASTM E-84,
NEPA 258 AND UL 123.
D. EQUIPMENT
I. HVAG CONTRACTOR TO FURNISH ALL HVAG EQUIPMENT INDICATED
AND /OR SGH EIDER ED ON THE DRAWINGS COMPLETE NTH BASES,
ISOLATORS, SUPPORTS Alm OTHER REQUIRED ACCESSORIES.
2. IRS COMPLETE AND PLACE IN PROPER OPERATION PEER
MANUFACTURER'S RECOMMENDATIONS, LUBRICATE AND ADJUST AS
REQUIRED.
3. EQUIPMENT TO BE MAKE AND MODEL AS SCHEDULED 11NLE56 OPFER
APPROVED, EQUIVALENT' GILJALITY AND FEFORMANCE EQUIPMENT 15
SLBMIITTED AS 9.ISTITUTiON. ALL SUBSTITUTIONS SUBJECT TO
ACCEPTANCE HITFHOUT GIUALIFIGATION BY OMER, LANDLORD AND
ARCHITECT.
4. CONTRACTOR TO OBTAIN VAV DEVICE SET (5) FROM LANDLORD
E BALANCING, START UP AND INST RUGT1ON5
1. AFTER INSTALLATION AND E GVIPMEtf 15 PLACED IN OPERATION,
HVAL CONTRACTOR 15 RESPONSIBLE FOR BALANCING SYSTEMS TO
DESIGN FLOW YITH REPORT SUBMITTED TO OM ER BALANCING SHALL
BE PERFOR FD BY AN INPmENT AABG OR NEBB CERTIFIED
SUBCONTRACTOR
2. START UP AND PLATE ALL SYSTEMS IN OPERATION AND TAG ALL
SWTCHES AND CONTROLS WITH PERMANENT LABELS.
3. INSTRUCT OMER oN PROPER OPERATION AND MAJNTFNANCE OF
SYSTEM.
F. CONTROLS
I. FURNISH AND INSTALL ALL CONTROLS FOR HVAG SYSTEMS. PROVIDE
ALL RAYS AND DEVICES REQUIRED FOR COMPLETE OPERATION.
MOUNT ALL CONTROL.5 FURNISHED AS ACCESSORIES TO EQUIPMENT AND
PROVIDE ALL CONTROL (LOW VOLTAGE) WIRING OR POWER WIRING
REQUIRED FOR CONTROL SYSTEM WHERE NOT SPECIFICALLY SHOPE ON
ELECTRICAL PLANS. ALL POWER WIRING AND DQ'OSED CONTROL
WIRING SHALL BE IN Et4T CONDUIT. CONGEALED CONTROL WRING IN
CEILING FUMES MAY BE UL LISTED PLENUM RATED GABLE NEATLY
SUPPORTED IN WIRE RINE/5. ALL CONDUIT SHALL BE INSTALLED PER
NEC.
2. SMOKE CONTROL
MECHANICAL CONTRACTOR SHALL FURNISH, INSTALL AND WIRE A
PHOTO-ELECTRIC DUCT SMOKE DETECTOR AND REMOTE TEST SNITCH
AND ALARM AT EACH FAN POWERED TERMINAL TO SHUT DOWN FAN ON
ALARM. REFER TO DETAIL 014 DRAWING. LOCATE ALARM AND TEST
SWITCH PER FIRE MARSHAL'S DIRECTION.
3. NO THERMOSTATS SHALL BE INSTALLED ABOVE ANY HEAT PRODUCING
EQUIPMENT.
4. CONTROL SEGIEI SHALL BE AS FOLLOWS:
A FPB-I CONSTANT VOLJIyE FAN POWERED TERMINAL - THERMOSTAT
SHALL MODULATE VAV DAMPER, SUPPLY AIR FAN, AND ELECTRIC
DUCT HEATER TO MAINTAIN SPACE SET POINT. VAV DAMPER
SHALL OPEN AND FAN SHALL RIJN CONTINUOUSLY URNS ALL
OCCUPIED HOURS. VAV DAMPER SHALL GLOSE AND FAN AND
ELECTRIC HEATER SHALL CYCLE TO MAINTAIN SPACE HEATING
SET POINT DURING UNOCCUPIED HOURS. VAV DAMPER SMALL
CLOSE TO MINMIM POSITION, FAN SHALL DPERATE, AND
EECTRIG HEATER SHALL CYCLE TO MAINTAIN SPACE SET POINT
IN HEATING MODE VAV PAMPER AND SUPPLY AIR FAN SHALL
MODULATE TO MAINTAIN SPACE SET POINT AND CONSTANT AIR
VOLUME DURING OCCUPIED HOURS IN COOLING MODE
ELECTRICAL SYSTEM
A SCOPE
I. INGLU7E ALL LABOR, I@JIP4131T, TOOLS AND MATERIALS FOR
ELECTRIC DISTRIBUTION, AS 5HOWN ON DRAWINGS.
2. EXTEND NEW POWER SERVICE TO SPACE AS SHOWN ON DRAWINGS
THROUGH A I2O/2O6 VOLT, 3 PHASE, 4 WIRE LANDLORD
SNITGHBOAfRD.
3. ALL ELECTRICAL WORK, I14GL POWER WIRING FROM PANEL IN
BUILDING AND WIRING OF O1>IER ITEMS INDICATED.
4. FURNISH AND INSTALL NEW LIGHTING, E EERGEECT AND EXIT
LIGHTING AS INDICATE? ON DRAWINGS.
5. PROVIDE FACILITIES FOR A NEW TELEPHONE SERVICE.
6. PROVIDE A MANUAL FIRE ALARM SYSTEM AS SHOWN ON DRAWINGS.
7. OTHER ELECTRICAL ITEMS INDICATED ON DRAHIFEGS OR REQUIRE? FOR
COMPLETE INSTALLATION, INCLUDING SOUND AND ANFIAHGIATOR
SYSTEMS.
5. ANY INSTALLATION COSTS ASSESSED BY UTILITY COMIPANII=S FOR
INCOMING NICE INSTALLATION SHALL BE INGLUDED IN BID AND
PAID FOR BY THE ELECTRICAL CONTRACTOR
B. CONDUIT INSTAL
I. ALL WIRING TO BE INSTALLED IN CONDUIT IN ACCORDANCE WITH THE
NE.G. AND 50 THE REQUIRED CONDUCTORS MAY BE FILLED WITHOUT
INJURY OR STRAIN AND SLY SUPPORTS). INCREASE CONDUIT
TRADE SIZE AS REWIRED FOR LONG PULLS ABOVE MINIMUM REQUIRED
SIZE.
2. ALL CONDUIT SHALL BE ROUTED TO PRESERVE HEADROOM, SQUI1913
ACCESS, AND ARCHITECTURAL CLEARANCES FOR FlNISHE6, INCLUDING
CEILING HEIGHTS WITHOUT ADDITIONAL CLARIFICATION.
COORDINATE WITH ALL OTI-E TRADES 5o THAT CONI7IJIT RUNS DO NOT
BLOCK ARCHITECTURAL REQUIREMENTS FOR FINISHED CONSTRUCTION.
3. ALL CONDUITS TO a CONGEALED IN BUILDING NEON CONSTRICTION
KURE AVAILABLE
4. E)O CONDUIT MAY BE RUN ON EXISTING MASONRY WALLS IN
EQUIPMENT ROOMS. VERIFY ALL LOCATIONS WITH OWNER PRIOR TO
ROU6H-IR
5. INTERIOR HIRING To BE IN57ALLED IN EL.Ec RIcAL METALLIC.
TURING (BIT) PITH STEEL SET %R& TYPE COUPLINGS AND
CONNECTORS. WHERE CONCEALED, USE TYPE MC ARMORED CABLE. EMT
OR MG GABLE 15 NOT APPROVED FOR INSTALLATION IN CONCRETE
SLA% OR UNDERGROUND.
6. CONDUIT ON BUILDING EXTERIOR SHALL_ BE RIGID Ad /MINIM OR
GALVANIZED STEEL WITH WFAT1 -TIGHT FITTINGS AND DEVICES.
PROVIDE EXPANSION FITTINGS WHERE CONDUITS EXIT FROM GRADE.
1. UNDERGROUND CONDUIT BELOW GRAPE SHALL BE RIGID SCFEDIJI.E 40
PVC WITH SOLVEMf WIELD FITTINGS. INSTALL CODE SIDED GROUND
CONDUCTOR IN ALL PVC CONDUIT. PENETRATIONS OF FLOOR SLABS
SHALL BE MADE WITH RIGID GALVANIZES 51E19_, 11-ERE CONDUITS
ARE EXPOSED TO MECHANICAL DAMAGE. PVC PENETRATIONS ARE
ACCEPTABLE *ERE PROTECTED FROM PHYSIGAL DAMAGE PROVIDE
EXPANSION FITTINGS AS RECOMMENDED BY TINE MANJFAGTRER
5. NO CONDUIT TO BE RUN EXPOSED ON EXTERIOR OF BUILDING WALLS
OR ON 11-E FLOORS.
q. PROVIDE ALL FULL BOXES AND FITTINGS 114EREVER NECESSARY OR
SHOWN. ALL STRAIGHT CONDUIT WADS SHALL NOT EXCEED 100 FEET
WITHOUT PLAT. BOX, NOT OVER 15 FEET FOR RAN WITH ONE (I)
RIGHT ANGLE BEND AND NOT OVER 50 FEET FoR RUN WITH TWO (2)
RIGHT AN5LE5.
10. ALL CONDUIT SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH
THE NEG. CONDUIT SHALL BE IFLTLY SUPPORTED FROM
SIT:IMRE AND NOT FROM DUCTWORK, CEILING HANGERS OR CEILING
SUPPORT HIRES. NO CONDUIT SHALL ROUTE THROUGH ROOFTOP
EQUIPMENT RETURN AIR OPENINGS.
11. FINAL COFNCTION TO LIGHT FIXTURES AND E UIPMHEIT SHALL BE
MADE WITH FLEXIBLE STEEL CONDUIT ('EREENFED" - 6' MAXIMUM
LENGTH) IN DRY AREAS AND LIQUID TIGHT ft XIBLE METALLIC
CONDUIT ('SEALTiiE IN DAMP OR PET AREAS.
12. ALL U 1Y CONDUITS ARE TO BE PROVIDED WITH FULL WIRE5 AND
NYLON EUSHI1SS AT BOTH ENDS.
13. GON DUri FEFEiRA1ION5 OF ROCfS SHALL BE MADE WITH PATE FIF
CURBS OR PIPE SEALS AS REQUIRE, INSTALLED BY THE PROJCT
ROOFING CONTRACTOR FOR EXISTING ROOFS, THE PENETRATION
SHALL BE MADE BY AN OPENER APFROVEDD CONTRACTOR TO MAINTAN
THE ROOF WARRANTY. CONNECTIONS TO ROOF TOP EQUIPMENT SHALL
BE MADE THROUGH THE ROOF CURB WEHERE CURB 15 DESIGNED FOR
- THIS CONNECTION.
14. FROVIDE SURFACE WIRE MOLD LD AND BOXES FOR SURFACE WORK IN
EMBED AREAS WHERE SPECIFICALLY APPROVED BY 11•E ARCHITECT.
15. CONDUITS ROUTED BELOW FLOOR SLAB ARE TO BE COORDINATED WI114
o11-ER BH._OWL -SLAB UTILITIES. INSTALL CONDUITS BOW FLOOR
SLAB, NOT IN FLOOR POUR. GUT AND PATCH E. XISTiNG IWORS
WERE CONDUIT MUST BE CONGEALED IN OR BELOW FLOOR CONDUITS
SHOWN RIJN OVERHEAD CANNOT BE RAN BISON GRADE WITHOUT PRIOR
APPROVAL AND COORDINATION WITH 1TE ENGINEER AND ALL AFFECTED
CONTRACTORS.
16. PROVIDE SEALS YEN CONDUIT I5 PASSING FROM GOLD TO WARM
ENVIRON NITS. U5E SILICONE SEALANT AROUND BOXES AND
FOR OF RACEWAYS AND SEALING COMPOUND OR FOAM -IN- PLACE
SEALANT WITHIN RACBNAYS.
G. OUTLET BOXES
I. SUPPORT ALL BOXES FROM BUILDING STRUCTURE INDEPENDENT OF 1W
CONDUIT SYSTEM.
2. BUSH DEyVIGE BOXES IN MASONRY WALLS SHALL BE DE51614150 FOR
TI-E PURPOSE WITH RAISED COVER.
3. WIRING DEVICE BOXES FOR SURFACE CONDUIT WORK SHALL BE F5
SERIES CAST BOXES.
4. DEVICES ON BUILDING EXTERIOR SHALL BE WEATHERPROOF NSA 3R.
5. BOXES FOR FLUSH MOUNTING SHALL BE 4' 5:31/ARE MINIMUM WITH
DEVICE RING FOR WIRING DEVICE TO BE INSTALLED. COMNIJNIGAiION
JJNGTION BOXES SHALL BE 2 -1/8' DEEP MINIMUM.
6. PROVIDE CUSTOM MADE DEVICE BOXES TO ACCOMMODATE CONDUIT
PENETRATIONS SHOWN ON PLANS.
D. HIRE AND GABLE
I. WIRE AND CABLE SHALL BE AS FOLLOWS:
A. #I2 AWIG AND CO AWG SOLID OR STRANDED CONDUCTOR
600 VOLT, TYPE THEN/THEN, XH-111, OR TI-IN MAO DEGREES
G).
B. 4 AWG TO AND INCLUDING #500 KGMIL AWE, STRANDED
CONDUCTOR, COPPER 600 VOLT, TYPE TFP'WIHEEN, XFIHN OR
TEM MAO DEGREES G.).
G. TYPE Th1ff1 DIGRESS G) WIRE FROM OUTLET BOX TO LI61-11
FIXTURES.
D. 44I4 AW5 MAY BE USED FOR LOW VOLTAGE CONTROL WIRING
ONLY.
E. ELECTRICAL CONTRACTOR MAY OPTION TO USE TYPE MG (METAL -
CLAD CAS) FOR BRANCH CIRCUITS FOR CONGEALED WORK, IF
APPROVED BY OWNER. AND LANDLORD PRIOR TO 8117.
REVIE p�p,NCE
CODE. A 0 ~ NEC
NF
:E8 - 8 2a
jWI ION
2. COLOR CODING SHALL BE U5)D FOR ALL WIRE AND GABLES IN
ACCORDANCE WITH N.EG. CODING STANDARDS. CONTROL CONDUCTORS
SHALL BE CONTI1E000SLY DOLOR CODED. GROUND CONDUCTOR SHALL
BE GREER
3. JOINTS IN #IO MG AND SMALLER WIRE SHALL BE MADE WITH
"SCOTCH LOCKS' OR EQUAL) AND BE INSULATED WITH SCOTCH *33
ELECTRICAL TAPE.
4. .JOINTS IN #6 AWG AND LARGER SHALL BE MADE •TH F SSURE TYPE
MECHANICAL CONNECTOR AND INSUATED WTH ELECTRICAL TAPE TO
150% OF THE INSULATING VALUE OF THE CONDUCTOR
5. INCREASE WIRE SIZE ELY ONE AMERICAN WIRE GAUGE SIZE FOR EVERY
15 LINEAR FEET OF HIRE RUN.
E SWITCHES, SAFETY
I. SAFETY SWITCHES SHALL BE HEAVY DUTY, SiZE AND ELECTRICAL
CHARACTERISTICS INDICATED, WRFACE MOIMfED, FUSIBLE RATED AT
250 VOLTS ON THE 206 VOLT SYSTEM AND 600 VOLTS ON THE 4E0
VOLT SYSTEM, AMPERE RATINGS AS NOTED 014 THE DRAWINGS, 60
HERTZ, THE (3) BLADES, INCORPORATING QUICK -MAKE, QUICK -
BREAK TYPE SWITCHES.
2 FUSES: UNLE55 INDICATED ON THE DRAWINGS A5 NON-9 TYPE,
PROVIDE I3l5E5 FOR SAFETY SWITCHES. FUSES TO BE TIME -DRAY,
CURRENT-LIMITING UL CLASS PKI, AND HAVE AN INTfRRJP11/6
RATING OF 200P00 RYE, AMPS SYMMETRLGAL
3. DISCONNECTS FOR 120 VOLTS, SINGLE PHASE EGVEMENT SHALL BE
HEAVY DUTY TYPE SUITABLE FOR THE SERVICE INTENDED. iNUJJDE
TI-E2MAL OVERLOAD PROTECTION INTEGRAL WITH DISGONUECT FOR
MOTORS OR WHERE REQUIRED BY GODS
4. SWITCHES INSTALLED IN OUTDOOR LOCATIONS SHALL BE
WEATHERPROOF RE NA 3R
5. PROVIDE 134E/RAVED NAMEPLATE FOR EACH DISC/241E0T SWITCH
INDICATING VOLTAGE, PHASE, LOAD SERVED, AND CIRCUIT ORIGIN.
F. LIGHTING AND POWER PANEl80ARDS
1. PROVIDE DEAD -FRONT SAFETY TYPE LIGHTING AND POWER
PANE/ BOARDS AS INDICATED, WITH SWITCHING AND PROTECTIVE
DEVICES IN (IANTiTIES, RATINGS, TYPE, AND ARRANCIENENT AS
SHOWI, EGIJIPPE D WITH STANDARD BUS BARS, FULL -SIZES NBJTRAL
BAR, WITH BOLT -IN TYPE MOLDED CASE BRANCH CIRCUIT BREAKERS
FOR EACH CIRCUIT, WITH TOGGLE HANDLES THAT INDICATE WHEN
TRIPPED. PROVIDE A BARE UNIFSULAT D GROUNDING BAR SUITABLE
FOR BOLTING TO ENCLOSURE. PROVIDE TYPED DIRECTORY.
2. PROVIDE ENGRAVED NAME=PLATE FOR EACH PANELBOARD INDICATING
VOLTAGE, PHASE, PANEL NAME, AND FEEDER ORIGIN
3. MAFNIFAGIURE . SHALL PROVIDE INTERRUPTING RATINGS FOR ALL
EQUIPMENT BASED ON FAULT CURRENT 5HO41 ON PLANS. SERIES
RATED EQUIPMENT SHALL BE LABELED ED '" SERIESS RATED - REPLACE
WITH IDENTICAL COMPONENT PARTS' WITH PERMAFETT LABEL
4. ALL CIRCUIT BREAKERS SERVING HID LIGHTING SHALL PROVIDE HID
CIRCUIT BREAKERS.
5. ALL CIRLUrr BREAKERS SERVING AIR CONDITIONING EQIJIPMEtT
SHALL BE 'HAGR' RATED TO GOMEPLY WITH EQUIPMENT LISTING.
6. PROVIDE ARC-FLASH HAZARD LABEL ON ALL PAHELBOARDS.
G. GROUNDING
1 ENTIRE POKER SYSTEM SHALL BE B FEG11ViiY GROUNDED, INCLUDING
ALL EXPOSED NONE CARRYING PARTS OF ELECTRICAL
EGJIPMENT IN FULL ACCORDANCE WITH N.E.C. ARTICLE 250.
2. A GREEN PIGTAIL SHALL BE INSTALLED FROM GROUNDING SLOTS OF
GROUNDING OUTLETS TO OUTLET BOXES IN EACH IFETANGE k1l-if3RE
RECEPTACLE ATTACHMENT BAR 15 NOT IN DIRECT CONTACT WITH THE
OUTLET BOX.
3. THE EXISTING BUILDING SYSTEM GROUND SHALL SE EXTENDED TO ALL
FEW !'^ARK.
4. TEST GROUND SYSTEM AFTER INSTALLATION FOR A MAXIMUM 5 OHMS
TO GROUND AS MEAWRED IN FEBRUARY. PROVIDE ADDMONAL
GROUND RODS AS REWIRED.
5. ALL METAL PIPING., SYSTEMS, DUCTWORK ARID STEEL FRAMES SHALL
BE BONDED TO E3EGTRIGAL SYSTEMS IN COMPLIANCE W1T14 THE
NEC.
H. LIGHTING
I. STRIDE RITE TO FURNISH LIGHTING FIXTURES WITH LAMPS AS SHOWN ON
SCHEDULE ON DRAWINGS. E.G. TO ItErIALL
2. COORDINATE= FIXTURE TYPE AND TRIM WITH CEILING CONSTRUCTION.
3. ALL LAMPS SHALL BE RATED BY MANUFACTURER FOR INSTALLATION IN
N'S.IFIED FIXiUJRE.
4. ALL FIXTURES IN LAY -IN CEILING SHALL BE SUPPORTED FROM 1IE
STRUCTURE INDEFENDE NT OF 1-E CEILING SYSTEM AT ALL FOUR (4)
CORNERS AND ATTACHED WITH GRID CLIPS.
5. THE MANUFACTURER OF EACH LIGHTING FIXTURE SHALL REAM THE
APPLICATION OF 1415 EQUIPMENT AND CERTIFY AT THEE TIME OF SHOP
DRAWING SUBMIITTAL THAT HIS FIXTURE HAS DEEM PROPERLY APPLIED
AND GAN BE INSTALLED, MAINTAINED AND SERVICED VCEIRE SHOPI4 ON
Ti•E DRAWINGS.
6. ALL FLUORESCENT LAMPS SHALL BE DOLOR CORRECTED, iRI- PHOSPHOR
LAMPS OF COLOR TEWERATURE SPECIFIED. ALL LAMP' SHALL BE BY
TI-E SAME MAIL EAGTURER AND BE GE SYLVANIA- 05RAM, OR
PHLLIPS. IF NO COLOR 15 SFEGDFIED, IT WILL BE SELECTED BY
THE ARCHITECT.
I. EMERGENCY LIGHTING AND EXIT SIGNS
I. FURNISH AND INSTALL BATTERY POPERED 1 GE NCY LIGHTS AND
EXIT SIGNS As SHOWN AND SCHEDULED ON THE DRAWINGS.
2. THE WIRING AND INSTALLATION SHALL GOFEORM TO THE
REQUIREMENTS OF T1-E NFL. AND NEPA LIFE SANI=TY CODE
3. BATTERi' PACKS INTEGRAL TO FLUORESCENT FIXTURES SHALL PROVIDE
A MINIMUM OF 1400 MIENS AND OPERATE TWO LAMPS IN EACH
FIXTURE
J. TEMPORARY
I. 114I5 CONTRACTOR TO PROVIDE ALL TEMPORARY LIGHTING AND POPIED
AS REQUIRED FOR ALL TRADES.
2. ALL TEMPORARY WIRING WM11E13 SHALL BE REMOVED BY THIS
CONTRACTOR
K 713€194Ot SERVICE
I. SERVICE GON515T5 OF AN EXISTING CONDUIT SYSTEM INCOMING
SERVICE AS INDICATED ON DRAWINGS. THIS CONTRACTOR SHALL
FULLY COORDINATE WITH AHD PROVIDE FACILITIES REWIRED BY THE
TELEPHONE UTILITY COMPANY FOR THE SERVICE INSTALLATION.
2. PROVIDE 3/4' FIRE RETARDANT TREAiED PLYWOOD BACKBOARDS WEHERE
INDICATED ON DR.ANINGS FOR U5E BY TELEPHONE SYSTEM
BACKBOARDS SHALL BE PAINTED BOTH SIZES WITH TWO (2) COATS OF
GRAY ENAMEL PAINT. PROVIDE 120 VOLT DUPLEX REGEPTAGLE
ADJACENT TO THE RIGHT SIDE LOCATED Tfi' AFF.
3. PROVIDE t6 AWG COPPER WRE OR 3/4' CONDUIT FROM BACKBOARD TO
MAIN BUILDING GROUND.
4. PROVIDE E3RPTY COFIDUUIT SYSTEM WITH TWb (2.) TWISTED PAIR #24
AWG CATEGORY 5 WIRE FROM EACH NEW OUTLET LOCATION TO
EXISTING TI3J= P1-I0NE CABINETS AS SHOWN ON DRAWINGS.
5. ALL OUTLET LOCATIONS SHOWN ON DRAWING ARE TO BE VERIFIB)
WITH THE OWED PRIOR TO ROUGH -IN.
6. OUTLET BOXES TO BE 4' SQUARE WITH SINGLE COVER PLATE AND
OUTLET NOTED ON DRAWINGS.
FLOC- 81�
RECEIVED
DEC 2 8 2007
PEHMIT CENTER
i
f7RRS // _20) - _I
ISSUE