Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG07-026 - QWEST
QWEST 6101 S 180 ST PGO7-026 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: 3523049120 6101 S 180 ST TUKW Value of Plumbing /Gas Piping: Fees Collected: doc: UPC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us QWEST 6101 S 180 ST , TUKWILA WA LA PIANTA LLC PO BOX 88028 , TUKWILA WA GREG LEAVER 6846 48 AV NE , SEATTLE WA Contractor: Name: CLEARVIEW MECHANICAL INC Address: 6846 48 AV NE , SEATTLE WA Contractor License No: CLEARNII051P4 $600.00 $107.50 Plumbing Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic 0 Dental unit, cuspidor 0 Dishwasher, domestic, with independent drain 0 Drinking fountain or water cooler (per head) 0 Food -waste grinder, commercial 0 Floor drain 0 Shower, single head trap 0 Lavatory 0 Wash fountain Receptor, indirect waste 0 Sinks 0 Urinals 0 Water Closet 0 PLUMBING /GAS PIPING PERMIT DESCRIPTION OF WORK: WATTS 009 QT - 1/2 RPBD. INSTALL A 1/2" REDUCED PRESSURE BACKFLOW DEVISE ON COLD WATER TO SERVE HUMIDIFIERS IN PHONE COMPANY EQUIPMENT AREA IN NE CORNER OF BUILDING Uniform Plumbing Code Edition: International Fuel Gas Code Edition: FIXTURE TYPE AND OUANTITY 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 527 -8515 Phone: 206 -527 -8515 Expiration Date: 10/16/2008 Steven M Mullet, Mayor Steve Lancaster, Director PGO7 -026 02/23/2007 08/22/2007 2003 2003 Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 0 Water heater and/or vent 0 Industrial waste treatment interceptor, including its trap and vent, except for kitchen type grease interceptors 0 Repair or alteration of water piping and/or water treatment equipment 1 Repair or alteration of drainage or vent piping 0 Medical gas piping system serving (1 -5) inlets /outlets for a specific gas 0 Medical gas piping (6 +) inlets /outlets 0 Gas Piping Gas piping outlets (0 -5) 0 Gas piping outlets (6 +) 0 PG07 -026 Printed: 02 -23 -2007 Permit Center Authorized Signature: Signature: Print Name: doc: UPC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does - ume to give authori violate or cancel the provisions of any other state or local laws regulating construction or the perfo = ' - ork. I am autho and obtain this plumbing /gas piping permit. Date: 0- Permit Number: PG07 - 026 Issue Date: 02/23/2007 Permit Expires On: 08/22/2007 Steven M Mullet, Mayor Steve Lancaster, Director Date: Da P This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG07 -026 Printed: 02 -23 -2007 Parcel No.: 3523049120 Address: 6101 S 180 ST TUKW Suite No: Tenant: QWEST 1: ** *PLUMBING AND GAS PIPING * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: PG07 -026 ISSUED 01/26/2007 02/23/2007 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire-resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. PG07 -026 Printed: 02 -23 -2007 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of wo Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Signature: Date: 2-2-3 PG07 -026 Printed: 02 -23 -2007 Site Address: Tenant Name: CGtlCgSY Property Owners Name: CDui85 r Mailing Address: Mailing Address: E -Mail Address: G AI%4 C 4 c )u 57 ; /2 7` Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: 7 E/ ,2/r9,Z ©5/Aq Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWIli Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** 61al 5 /R) 7 5r /o/ .S /Z30 7 '57 - 6'84.6 -4f3 r 44 ze9e" ci 4 -'iery ,/ WAddie/FL 6046 4E 7 fie ,V Cs4- ervi sic 4 Qtide Q:\Applications\Fotms- Applications On Line3-2006 - Plumbing -Gas Piping Permit Application.doc Revised: 4 -2006 bh Plumbing /GaPermit No. King Co Assessor's Tax No.: Z 3 4 22 Floor: / � r Suite Number: T /(4 LP City CONTACT PERSON -Who do we contact it is ready to be issued Name: /..614167/t C ( /Zi // ,P ,2/riT New Tenant: ❑ .... Yes -No wA State Zip State a5 ?S Day Telephone: 5 City Fax Number: - Z-7 7967 State Zip PLUMBING / GAS PIPING CONTRACTOR INFORMATION sc 4T7 City State Zip Day Telephone: 2G 52-7-e,5/5 Fax Number: 2_l� X27 - 2 7 ' Expiration Date: ,1L& / — All plans must be wet stamped by Architect of Record ARCHITECT OF RECORD Company Name: Mailing Address: Zip City Day Telephone: Fax Number: ENGINEER OF RECORD All plans must be wet stamped by Engineer of Record State City Day Telephone: Fax Number: Zip Page 1 of 2 Fixture Type: Qty Fixture Type: Qty Fixture Type.'; Qty F fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste R Clothes washer, domestic Floor drain Sinks �� /J 1) 1 Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Valuation of Project (contractor's bid price): $ 6 Scope of Work (please provide detailed information): /1.14Tr5 - P 7' 72_ RP13D .__L�5r,4 A l '4 ,,a ccro AzessUn[4 ∎i4c f irxu A32-1/5 0 ©N � / 0,4 922 5 vs //rC #2 � c7#-t--02 ut,d. T iQ . 6?"3. _ e/rnn d f3c Building Use (per Intl Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: 11i V W U.-A- Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LA S OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT O' - i AGENT: Signature:_ Print Name: Mailing Address: -46 TH ACA3 jAg Date Application Accepted: O lei 01_ Q:\Applications\Forms- Applications On LineU -2006 - Plumbing -Gas Piping Perini Application.doc Revised: 4 -2006 bh 00 Date Application Expires: Day Telephone: 2 52 sus 5; ?A7 7 e . Sewer: '11/1V VA LA- City Date: / 7-1 9 State Zip Staff Initials: Page 2 of 2 Parcel No.: 3523049120 Address: 6101 S 180 ST TUICW Suite No: Applicant: QWEST Receipt No.: R07 - 00117 Initials: JEM User ID: 1165 Payee: CLEARVIEW MECHANICAL TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Descript ion PLAN CHECK - NONRES PLUMBING - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 000/345.830 000/322.100 RECEIPT Permit Number: PG07 -026 Status: PENDING Applied Date: 01/26/2007 Issue Date: Payment Amount: $107.50 Payment Date: 01/26/2007 04:00 PM Balance: $0.00 Amount Payment Check 1922 107.50 Account Code Current Pmts 19.50 88.00 Total: $107.50 9 IL /29 9716 TOTAL 107 _5) doc: Receiot -06 Printed: 01 -26 -2007 Prof A....e 5+ Type of Inspection: U Address: Date Called: Special Instructions: Date Wanted: 7 Requester: Phone No: P6o7-a26 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206 )431 3 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Corrections required prior to approval. 70 COMMENTS 1,4 .00 REINSPECTION FE id at 6300 Southcenter Bt ec pt No.: Date: REQUIRED. Pnorjto inspection, fee must lie d., Suite 100. C It to sechedute reinspection. Date: , 4`it "•0'. Jan . 26. 2001• 5 : 53PM- ..- ...-- JONANSEN MECHANICAL-- — - -w, PUMA 'Ns' GOPffP WALL MOUNTED HUMIDIFIER 2. MOUNT hi.MIDIFIER SENSOR ON COLUMN AND EXTEND WIRE AND CONDUIT UNDER RAISED FLOOR AND CONNECT TV hLMIDIFIER_ GONDENSATE RAO 4. EXTEND CONDENSATE DRAIN LINE UNDER RAISEp PL.00R AND DRAIN INTO JANITORS SINK, TIE INTO EXISTING WATER LINE. FIND COORDINATE EXACT LOCATION. NEW WATT 909 DAGKFL.OW PREVENTOR min AIR en ro INSTALLED DY CERTIFIED 6ACKFLOW PREVENOR INSTALLER. NEW WATER LINE AND CONDENSATE LINE TO. DE INSTALLED UNDER RAISED rwoR. S. CONNECT WATER LINE TO hIUMIDIFIER PER MANLX"ACTURES INSTALLATION INSTRIXGTIGNS. 9. CONNECT CONDENSATE LINE TO hIUMIDIFIER PER MANU INSTALLATION INSTRUCTION, 10. WALL MOUNTED REMOTE ALARM. ALARM TO HAVE LleHTS AND AUDIDLE ALARM. ALRARM r0 DE MOUNTED IN 1100. 11. UNE TO DROP DOWN AND RUN UNDER RAISED FLOOR. RECEIVED CITY OFTUI(WIIA JAN 2 6 ZOOT PERMITCENTER REVIEWE r NCE CODE COMP 1 FEB 2 1 1.00 aNGVilaC4N t ? &vk 0 2 1 i RECEIVED 01- 26 -'07 16:12 FROM- 4254866933 TO- c , Permit No. Appeal c' the vlolat:n d pppiv' - 3 . . No.5418 P. 1 rat cart e fig att • P001/001 4 GPI of Tukw 1a Engineer Approval Series 009 Reduced Pressure Zone Assemblies Sizes: 1/4" - 3" (8 - 80mm) Series 009 Reduced Pressure Zone Assemblies are designed to protect potable water supplies in accordance with national plumbing codes and water authority requirements. This series can be used in a variety of installations, including the prevention of health hazard cross connections in piping systems or for con- tainment at the service line entrance. This series features two in -line, independent check valves, cap- tured springs and replaceable check seats with an intermediate relief valve. Its compact modular design facilitates easy mainte- nance and assembly access. Sizes IA" -1 " (8 - 25mm) shutoffs have tee handles. Features • Single access cover and modular check construction for ease of maintenance • Top entry - all internals immediately accessible • Captured springs for safe maintenance • Internal relief valve for reduced installation clearances • Replaceable seats for economical repair • Bronze body construction for durability 1 /4" - 2" (8 - 50mm) • Fused epoxy coated cast iron body 21/2" and 3" (65 and 8omm) • Ball valve test cocks — screwdriver slotted IA" - 2" (8 - 50mm) • Large body passages provides low pressure drop • Compact, space saving design • No special tools required for servicing Specifications A Reduced Pressure Zone Assembly shall be installed at each potential health hazard location to prevent backflow due to backsiphonage and/or backpressure. The assembly shall con- sist of an intemal pressure differential relief valve located in a zone between two positive seating check modules with cap- tured springs and silicone seat discs. Seats and seat discs shall be replaceable in both check modules and the relief valve. There shall be no threads or screws In the waterway exposed to line fluids. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seated Isolation valves, four resilient seated test cocks and an air gap drain fitting. The assembly shall meet the requirements of: USC Manual 8th Editiont; ASSE Std. 1013; AWWA Std. C511; CSA B64.4. Shall be a Watts Regulator Co. Series 009. tDoes not indicate approval status. Refer to Page 2 for approved sizes & models. Test Cock No. 3 Bali Type Test Cocks Test Cock No. 2 First Check Module Assembly R.P. Zone Relief Valve Assembly FILE COPY For Health Hazard Applications Job Name 2 C�/ ! 7 / K ,P � A�) Contractor Job Location 649/ S /6 � " Ki Approval Contractor's P.O. No Representative G'_gi6*Qv/Bc> .0 A'• L 2" 009M2QTHC ∎Ills �(�._-_� ■, / /,lrj ■� 1 ` I / % !ittI� ,.:!r talk.. ow. Avaii attsBox Insulated Enclosu or more information, send for literature ES -V! IMPORTANT INQUIRE WITH GOVERNING AUTHORITIES FOR LOCAL INSTALLATION REQUIREMENTS ES -009 KWILA N 2 6 2007 PERMITCENTER Test Cock No. 4 Second Check Module Assembly Water Outlet W ATI'S® REGULATOR USA: 815 Chestnut St, No. Andover, MA 01845- 6098 :www.wattsreg.com Canada: 5435 North Service Rd., Bu tington, ONT L7L 5H7; www.wamoreda.ca Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incunng any obligation to make s changes and modifications on Watts products previously or subsequently sold. F ti-- OZ(D MODEL for 909, 009 and 993 sizes DRAIN OUTLET In. mm . In. DIMENSIONS A mm in. B mm WEIGHT lbs. kgs. 909AG -A ''R -'f" 009, % 13 2 60 3'% 79 .625 .28 3 /i 009M2/M3 909AG -C W-1' 009/909, 1 25 3'% 83 4'%e 124 1.50 .68 1 -1 %' 009M2 909AG -F 1W-2' 009M1, 2 51 4 111 6% 171 3.25 1.47 1W-3' 009/909, 2" 009M2, 4 "-6" 993 909AG-K C-6" 909, 3 76 6% 162 9 243 6.25 2.83 8 " -10" 909M1 909AG -M 8' -10' 909 4 102 7% 187 11% 394 15.50 7.03 909EL -A 'A - 'W' 009, Y4' 009M2/M3 - - - - - - - - 909EL-C 3 4 -1" 009/909. - - 2% 60 2%e 60 .38 .17 ' 909EL -F 1%'-2" 009M1, - - 3 92 3% 92 2 .91 1%'-2" 009/909, 2" 009M2. 4"-6" 993 ' 909EL -H 2W-3' 009/909 - - - - - - - - Vertical PC - LH - SH - HC - Prefix: C Available Models: 1/4" - 2" (8 - 50mm) Suffix: QT - quarter -turn ball valves S - bronze strainer LF - without shutoff valves AQT - elbow fittings for 360° rotation 3 /4" - 2" (20 - 50mm) only internal Polymer Coating locking handle ball valves (open position) stainless steel ball valve handles 21/2" inlet/outlet fire hydrant fitting (2" valve) U - clean and check strainer 3 /4" - 1" (20 - 25mm) only union connections (see ES-U009) Available Models: 21/2" - 3" (65 - 80mm) Suffix: NRS - non - rising stem resilient seated gate valves OSY - UUFM outside stem and yoke resilient seated gate valves S -FDA - FDA epoxy coated strainer QT -FDA - FDA epoxy coated quarter -turn ball valve shutoffs LF - without shutoff valves S - cast iron strainer Note: The installation of a drain line is recommended. When installing a drain line, an air gap is necessary (see ES -AG). Materials: 1/4" - 2" (8 - 50mm) Bronze body construction, silicone rubber disc material in the first and second check plus the relief valve. Replaceable poly- mer check seats for first and second checks. Removable stain- less steel relief valve seat. Stainless steel cover bolts. Standardly furnished with NPT body connections. For optional bronze union inlet and outlet connections, specify prefix U ('h" - 2 "(15 - 50mm)). Series 009QT furnished with quarter turn, full port, resilient seated, bronze ball valve shutoffs. Air Gaps and Elbows Materials: 2 and 3" (65 - 80mm) • (FDA approved) Epoxy coated cast iron unibody with bronze seats • Relief valve with stainless steel seat and trim • Bronze body ball valve test cocks Pressure / Temperature Series 009'/4" - 2" (8 - 50mm) Suitable for supply pressure up to 175psi (12 bar). Water temperature: 33 °F -180 °F ( -3 °C - 75 °C). Sizes 21/2" and 3" (65 and 80mm) are suitable for supply pressures up to 175psi (12 bar) and water temperature at 110 °F (43 °C) continuous, 140 °F (60 °C) intermittent. Standards USC Manual 8th Editiont ASSE No. 1013 AW WA C511 -92 CSA B64.4 IAPMO File No. 1563. tDoes not indicate approval status. See below for approved models. Approvals ASSE, AWWA, CSA, IAPMO Approved by the Foundation for Cross - Connection Control and Hydraulic Research at the University of Southern Califomia. Approval models QT, AQT, PC, NRS, OSY. UL Classified 3 /4" - 2' (20 - 50mm) (LF models only) 21/2" and 3" (65 and 80mm) with OSY gate valves. I NV 1 B SIZE (DN) ki. mm In. A mm k1. 8 mm ki. DIMENSIONS C mm (APPROX.) D !n. mm ki. L mm Li. STRAINER DIMENSIONS M mm N !n. mm WEIGHT lbs. kg. 1 /4 8 10 250 4% 117 3% 86 1'% 32 5% 140 2%8 60 2% 64 5 2 % 10 10 250 4 117 3% 86 1'h 32 5% 140 2% 60 2 64 5 2 ' 65 33% 845 15% 403 4% 114 16% 416 18 %8 460 7% 197 10 270 166 75.3 009NRS 15 10 250 4% 117 3 86 1'% 32 5 140 2% 70 2'% 57 5 2. 3 /4 20 10 273 5 127 3'% 89 1'% 38 6 171 33Ae 81 2% 70 6 3 1 25 16 425 5'x4 140 3 76 2% 64 9'x4 241 3 95 3 76 12 5 1' 32 17%8 441 6 150 3'x4 89 2% 64 11 289 4 113 3 89 15 6 1% 40 17% 454 6 150 3 89 2' 64 11'/8 283 4 %e 124 4 102 16 7 2 50 21% 543 73/4 197 4'% 114 3'% 83 13' 343 5 151 5 127 30 13 MODEL SIZE DN DIMENSIONS (APPROX.) WEIGHT In. mm In. A mm in. C mm In. D mm E 1n. mm in. L mm In. R mm in. U mm lbs. kgs. 009LF 2 65 — — — — 4% 114 — — 18 460 — — 10% 270 76 34.5 0090SY 2'% 65 33% 845 15% 403 4% 114 16% 416 18 %8 460 7% 197 10 270 166 75.3 009NRS 2'% 65 33% 845 11% 289 4 114 16% 416 18 %8 460 7% 197 10% 270 161 73.0 009QT 2'% 65 33'% 845 6 152 4% 114 16%8 416 18'%8 460 73/4 197 10 270 150 68.0 009LF 3 80 — — — — 4'x4 114 — — 18'% 460 — — 10% 270 76 34.5 0090SY 3 80 34% 870 18'x4 470 4 114 16% 422 18 460 8% 222 10% 270 198 89.8 009NRS 3 80 34 870 12% 324 4 114 16% 422 18% 460 8 222 10% 270 191 86.6 009QT 3 80 34% 870 7 178 4'x4 114 16% 422 18'%8 460 8% 222 10% 270 158 71.7 Dimensions and Weight: 1/4" - 2" (8 - 50mm) 009 Suffix HC – Fire Hydrant Fittings dimension 'A' = 25' (637mm) 009 1 /s" – 2" Dimensions and Weight: 2 and 3" (65 and 80mm) 009 3 80 10% 257 7 178 10 254 tClearance for servicing Watts G -4000 Series QT - Ball Valves Capacity Performance as established by an independent testing laboratory. ' /." (8mm) 009QT kPa psi 138 20 117 17 96 14 76 1 55 8 35 5 AP O kPa psi 138 20 117 17 96 14 76 11 55 8 35 5 AP 0 kPa 172 138 103 69 psi 25 20 15 10 35 5 AP kPa psi 207 30 kPa psi 207 30 172 25 138 20 103 15 69 10 35 5 0 0 A 0 P ES- 009 0403 .25 .95 1.9 38 165 24 124 18 83 12 41 6 0 0 02 6 AP 07.6 23 .25 .60 .75 1 1.17 gpm .95 1.9 2.9 3.8 4.5 Ipm .50 5 9.5 '/" (10mm) 009QT .75 1.25 1.50 2.5 3.1 gpm 2.9 3 8 4.8 5.7 9.4 11.8 Ipm l" (15mm) 009QT 19 7.5 5 10 20 30 40 19 38 76 114 152 7.5 15 2.3 4.6 28.5 38 '/" (20mm) 009M3QT * gpm 47.5 57 Ipm 15 fps 4.6 mps ■ ■■■■■ ■ ■ •■■■■ •■■• ■ ■ ■ •••■•■■ ■■■■■i■ III■■■■■■■ ■■111!r..i ■ ■■ 11■ ■•■ ■■!Ti■ ■■■■ ■■ 11•■ ■ ■ ■ ■ ■ ■•■•■■■■■ i1 ■■•■ ■ ■ ■■■■■■ ■■■■ f1 •■■ ■ ■■ ■ ■ ■ ■■■■■■■ 10 14 18 22 26 30 34 38 53 68 84 99 114 129 7.5 15 2.3 4.6 1" (25mm) 009M2QT * 38 42 46 gpm 144 160 175 Ipm fps mps 50 60 70 80 gpm 190 228 266 304 Ipm fPs mps *Typical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec) kPa 172 138 103 69 35 0 kPa psi 207 30 172 25 138 20 103 15 69 10 35 5 0 0 AP 0 kPa 207 172 138 103 69 35 0 psi 25 20 15 10 5 0 AP 0 Psi 30 25 20 15 10 5 0 P O 0 kPa psi 172 25 138 20 103 15 69 10 35 5 0 0 AP kPa psi 172 25 138 20 103 15 69 10 35 5 0 0 ® Watts Regulator Co., 2002 1'/" (32mm) 009M2QT 38 76 1 4 152 190 228 5 7.5 10 1.5 2.3 3.0 1W (40mm) 009M2QT 10 20 30 40 50 60 70 80 90 100 110 120 gpm 38 76 1 4 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 20 40 60 80 76 152 228 304 5 7.5 1.5 2.3 2" (50 mm) 009M2QT 2 AN (65mm) 009 5 7.5 10 1.5 2.3 3.0 100 120 380 456 532 10 3.0 3" (80mm) 009 140 160 608 15 4.6 266 15 4.6 180 gpm 304 Ipm fps mps 200 gpm 684 760 Ipm fps mps gpm Ipm 15 fps 4.6 mps 0 25 50 75 100 125 150 175 200 225 250 275 300 325 gpm AP 0 95 190 285 380 475 570 665 760 855 950 1045 11401235 Ipm 5 7.5 10 fps 1.5 2.3 3.0 mps Printed in U.S.A. 1 r� 0 25 5 75 10 12.5 15 0 10 20 30 40 50 60 70 81 Capacity Performance as established by an independent testing laboratory. ' /." (8mm) 009QT kPa psi 138 20 117 17 96 14 76 1 55 8 35 5 AP O kPa psi 138 20 117 17 96 14 76 11 55 8 35 5 AP 0 kPa 172 138 103 69 psi 25 20 15 10 35 5 AP kPa psi 207 30 kPa psi 207 30 172 25 138 20 103 15 69 10 35 5 0 0 A 0 P ES- 009 0403 .25 .95 1.9 38 165 24 124 18 83 12 41 6 0 0 02 6 AP 07.6 23 .25 .60 .75 1 1.17 gpm .95 1.9 2.9 3.8 4.5 Ipm .50 5 9.5 '/" (10mm) 009QT .75 1.25 1.50 2.5 3.1 gpm 2.9 3 8 4.8 5.7 9.4 11.8 Ipm l" (15mm) 009QT 19 7.5 5 10 20 30 40 19 38 76 114 152 7.5 15 2.3 4.6 28.5 38 '/" (20mm) 009M3QT * gpm 47.5 57 Ipm 15 fps 4.6 mps ■ ■■■■■ ■ ■ •■■■■ •■■• ■ ■ ■ •••■•■■ ■■■■■i■ III■■■■■■■ ■■111!r..i ■ ■■ 11■ ■•■ ■■!Ti■ ■■■■ ■■ 11•■ ■ ■ ■ ■ ■ ■•■•■■■■■ i1 ■■•■ ■ ■ ■■■■■■ ■■■■ f1 •■■ ■ ■■ ■ ■ ■ ■■■■■■■ 10 14 18 22 26 30 34 38 53 68 84 99 114 129 7.5 15 2.3 4.6 1" (25mm) 009M2QT * 38 42 46 gpm 144 160 175 Ipm fps mps 50 60 70 80 gpm 190 228 266 304 Ipm fPs mps *Typical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec) kPa 172 138 103 69 35 0 kPa psi 207 30 172 25 138 20 103 15 69 10 35 5 0 0 AP 0 kPa 207 172 138 103 69 35 0 psi 25 20 15 10 5 0 AP 0 Psi 30 25 20 15 10 5 0 P O 0 kPa psi 172 25 138 20 103 15 69 10 35 5 0 0 AP kPa psi 172 25 138 20 103 15 69 10 35 5 0 0 ® Watts Regulator Co., 2002 1'/" (32mm) 009M2QT 38 76 1 4 152 190 228 5 7.5 10 1.5 2.3 3.0 1W (40mm) 009M2QT 10 20 30 40 50 60 70 80 90 100 110 120 gpm 38 76 1 4 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 20 40 60 80 76 152 228 304 5 7.5 1.5 2.3 2" (50 mm) 009M2QT 2 AN (65mm) 009 5 7.5 10 1.5 2.3 3.0 100 120 380 456 532 10 3.0 3" (80mm) 009 140 160 608 15 4.6 266 15 4.6 180 gpm 304 Ipm fps mps 200 gpm 684 760 Ipm fps mps gpm Ipm 15 fps 4.6 mps 0 25 50 75 100 125 150 175 200 225 250 275 300 325 gpm AP 0 95 190 285 380 475 570 665 760 855 950 1045 11401235 Ipm 5 7.5 10 fps 1.5 2.3 3.0 mps Printed in U.S.A. 1 r� 0 25 5 75 10 12.5 15 Capacity Performance as established by an independent testing laboratory. ' /." (8mm) 009QT kPa psi 138 20 117 17 96 14 76 1 55 8 35 5 AP O kPa psi 138 20 117 17 96 14 76 11 55 8 35 5 AP 0 kPa 172 138 103 69 psi 25 20 15 10 35 5 AP kPa psi 207 30 kPa psi 207 30 172 25 138 20 103 15 69 10 35 5 0 0 A 0 P ES- 009 0403 .25 .95 1.9 38 165 24 124 18 83 12 41 6 0 0 02 6 AP 07.6 23 .25 .60 .75 1 1.17 gpm .95 1.9 2.9 3.8 4.5 Ipm .50 5 9.5 '/" (10mm) 009QT .75 1.25 1.50 2.5 3.1 gpm 2.9 3 8 4.8 5.7 9.4 11.8 Ipm l" (15mm) 009QT 19 7.5 5 10 20 30 40 19 38 76 114 152 7.5 15 2.3 4.6 28.5 38 '/" (20mm) 009M3QT * gpm 47.5 57 Ipm 15 fps 4.6 mps ■ ■■■■■ ■ ■ •■■■■ •■■• ■ ■ ■ •••■•■■ ■■■■■i■ III■■■■■■■ ■■111!r..i ■ ■■ 11■ ■•■ ■■!Ti■ ■■■■ ■■ 11•■ ■ ■ ■ ■ ■ ■•■•■■■■■ i1 ■■•■ ■ ■ ■■■■■■ ■■■■ f1 •■■ ■ ■■ ■ ■ ■ ■■■■■■■ 10 14 18 22 26 30 34 38 53 68 84 99 114 129 7.5 15 2.3 4.6 1" (25mm) 009M2QT * 38 42 46 gpm 144 160 175 Ipm fps mps 50 60 70 80 gpm 190 228 266 304 Ipm fPs mps *Typical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec) kPa 172 138 103 69 35 0 kPa psi 207 30 172 25 138 20 103 15 69 10 35 5 0 0 AP 0 kPa 207 172 138 103 69 35 0 psi 25 20 15 10 5 0 AP 0 Psi 30 25 20 15 10 5 0 P O 0 kPa psi 172 25 138 20 103 15 69 10 35 5 0 0 AP kPa psi 172 25 138 20 103 15 69 10 35 5 0 0 ® Watts Regulator Co., 2002 1'/" (32mm) 009M2QT 38 76 1 4 152 190 228 5 7.5 10 1.5 2.3 3.0 1W (40mm) 009M2QT 10 20 30 40 50 60 70 80 90 100 110 120 gpm 38 76 1 4 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 20 40 60 80 76 152 228 304 5 7.5 1.5 2.3 2" (50 mm) 009M2QT 2 AN (65mm) 009 5 7.5 10 1.5 2.3 3.0 100 120 380 456 532 10 3.0 3" (80mm) 009 140 160 608 15 4.6 266 15 4.6 180 gpm 304 Ipm fps mps 200 gpm 684 760 Ipm fps mps gpm Ipm 15 fps 4.6 mps 0 25 50 75 100 125 150 175 200 225 250 275 300 325 gpm AP 0 95 190 285 380 475 570 665 760 855 950 1045 11401235 Ipm 5 7.5 10 fps 1.5 2.3 3.0 mps Printed in U.S.A. r� - 0 25 50 75 100 125 150 175 200 225 251 0 05 10- 295 380 475 570 665 760 885 951 Capacity Performance as established by an independent testing laboratory. ' /." (8mm) 009QT kPa psi 138 20 117 17 96 14 76 1 55 8 35 5 AP O kPa psi 138 20 117 17 96 14 76 11 55 8 35 5 AP 0 kPa 172 138 103 69 psi 25 20 15 10 35 5 AP kPa psi 207 30 kPa psi 207 30 172 25 138 20 103 15 69 10 35 5 0 0 A 0 P ES- 009 0403 .25 .95 1.9 38 165 24 124 18 83 12 41 6 0 0 02 6 AP 07.6 23 .25 .60 .75 1 1.17 gpm .95 1.9 2.9 3.8 4.5 Ipm .50 5 9.5 '/" (10mm) 009QT .75 1.25 1.50 2.5 3.1 gpm 2.9 3 8 4.8 5.7 9.4 11.8 Ipm l" (15mm) 009QT 19 7.5 5 10 20 30 40 19 38 76 114 152 7.5 15 2.3 4.6 28.5 38 '/" (20mm) 009M3QT * gpm 47.5 57 Ipm 15 fps 4.6 mps ■ ■■■■■ ■ ■ •■■■■ •■■• ■ ■ ■ •••■•■■ ■■■■■i■ III■■■■■■■ ■■111!r..i ■ ■■ 11■ ■•■ ■■!Ti■ ■■■■ ■■ 11•■ ■ ■ ■ ■ ■ ■•■•■■■■■ i1 ■■•■ ■ ■ ■■■■■■ ■■■■ f1 •■■ ■ ■■ ■ ■ ■ ■■■■■■■ 10 14 18 22 26 30 34 38 53 68 84 99 114 129 7.5 15 2.3 4.6 1" (25mm) 009M2QT * 38 42 46 gpm 144 160 175 Ipm fps mps 50 60 70 80 gpm 190 228 266 304 Ipm fPs mps *Typical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec) kPa 172 138 103 69 35 0 kPa psi 207 30 172 25 138 20 103 15 69 10 35 5 0 0 AP 0 kPa 207 172 138 103 69 35 0 psi 25 20 15 10 5 0 AP 0 Psi 30 25 20 15 10 5 0 P O 0 kPa psi 172 25 138 20 103 15 69 10 35 5 0 0 AP kPa psi 172 25 138 20 103 15 69 10 35 5 0 0 ® Watts Regulator Co., 2002 1'/" (32mm) 009M2QT 38 76 1 4 152 190 228 5 7.5 10 1.5 2.3 3.0 1W (40mm) 009M2QT 10 20 30 40 50 60 70 80 90 100 110 120 gpm 38 76 1 4 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 20 40 60 80 76 152 228 304 5 7.5 1.5 2.3 2" (50 mm) 009M2QT 2 AN (65mm) 009 5 7.5 10 1.5 2.3 3.0 100 120 380 456 532 10 3.0 3" (80mm) 009 140 160 608 15 4.6 266 15 4.6 180 gpm 304 Ipm fps mps 200 gpm 684 760 Ipm fps mps gpm Ipm 15 fps 4.6 mps 0 25 50 75 100 125 150 175 200 225 250 275 300 325 gpm AP 0 95 190 285 380 475 570 665 760 855 950 1045 11401235 Ipm 5 7.5 10 fps 1.5 2.3 3.0 mps Printed in U.S.A. DEPARTMENTS: C 61 01 building Division Complete Comments: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG07 - 026 DATE: 01 - - PROJECT NAME: QWEST SITE ADDRESS: 6101 S 180 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued Fire Prevention Putjc f Wo i ks . ' , Structural v�.t"Y 0 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUT)NG: Please Route 171 Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: DUE DATE: 02-27-07 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Planning Division El ❑ Permit Coordinator ❑ DUE DATE: 01-30-07 Not Applicable ❑ No further Review Required DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information 1 License CLEARMI051 P4 Licensee Name CLEARVIEW MECHANICAL INC Licensee Type CONSTRUCTION CONTRACTOR , UBI 601655738 Verify Workers Comp Premium Status Ind. Ins. Account id Business Type CORPORATION Address 1 6846 48TH AVE NE Address 2 City SEATTLE County KING State WA Zip 98115 Phone 2065278515 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 10/24/1995 Expiration Date 10/16/2008 Suspend Date Separation Date Parent Company Previous License HARTI**377N6 Next License Associated License Look Up a Contractor, Electr;^ian or Plumber License Detail %iv • tivawn Quip - J 41ojzigJtuStrIes . Search Look Up a Contractor, Electrician or Plumber Printer Friendly Version Home Safety Claims Ft Insurance Workplace Rights Trades � Licensing — ' Topic Index 1 Contact Info Find a Law or Rule Get a Form or Publication General/Specialty Contractor IA business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Page 1 of 3 https://fortress.wa.gov/lni/bbip/Detail.aspx?License=CLEARMI051P4 02/23/2007