Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG07-043 - B AND K TAYLOR
B & K TAYLOR 960 INDUSTRY DR PG0 7-043 Parcel No.: 2523049015 Address: Suite No: City of Tukwila 960 INDUSTRY DR TUKW Tenant: Name: B & K TAYLOR Address: 960 INDUSTRY DR , TUKWILA WA Owner: Name: CALWEST INDUSTRIAL PROP Address: C/O DELOITTE & TOUCHE LLP , 2235 FARADAY AVE #0 Contact Person: Name: CHUCK GILLETTE Address: 2310 112 ST SW, STE B2 , EVEREIT WA Contractor: Name: THOMAS INDUSTRIES INC Address: 20942 NE 78TH STREET , REDMOND, WA Contractor License No: THOMAII072P9 DESCRIPTION OF WORK: CONNECT GAS PIPING FROM NEW METER (PSE SUPPLIED) TO HEATED AIR MAKEUP UNIT, APPROX 28'. Value of Plumbing /Gas Piping: Fees Collected: $110.00 Plumbing Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic 0 Dental unit, cuspidor 0 Dishwasher, domestic, with independent drain 0 Drinking fountain or water cooler (per head) 0 Food -waste grinder, commercial 0 Floor drain 0 Shower, single head trap 0 Lavatory 0 Wash fountain Receptor, indirect waste 0 Sinks 0 Urinals 0 Water Closet 0 doc: UPC -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT FIXTURE TYPE AND OUANTITY 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 353 -9499 Phone: 425 868 -7742 Expiration Date: 10/15/2007 PG07 -043 04/06/2007 10/03/2007 $0.00 Uniform Plumbing Code Edition: 2003 International Fuel Gas Code Edition: 2003 Steven M Mullet, Mayor Steve Lancaster, Director Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 0 Water heater and/or vent 0 Industrial waste treatment interceptor, including its trap and vent, except for kitchen type grease interceptors 0 Repair or alteration of water piping and/or water treatment equipment 0 Repair or alteration of drainage or vent piping 0 Medical gas piping system serving (1 -5) inlets /outlets for a specific gas 0 Medical gas piping (6 +) inlets /outlets 0 Gas Piping Gas piping outlets (0 -5) 1 Gas piping outlets (6 +) 0 PG07 - 043 Printed: 04 -06 -2007 Permit Center Authorized Signature: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Signature: Print Name: r / �GG7T c7 doc: UPC-10 /06 Steven M Mullet, Mayor Steve Lancaster, Director Permit Number: PG07 -043 Issue Date: 04/06/2007 Permit Expires On: 10/03/2007 /U -e e: � '" _`� Date: O WO (a / I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pe formance , �,� authorized to sign and obtain this plumbing /gas piping permit. Date: y ' 7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG07 -043 Printed: 04 -06 -2007 Parcel No.: 2523049015 Address: Suite No: Tenant: 960 INDUSTRY DR TUKW B & IC TAYLOR 1: ** *PLUMBING AND GAS PIPING * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: PG07 -043 ISSUED 02/07/2007 04/06/2007 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 8: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 9: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. PG07 -043 Printed: 04 -06 -2007 doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: / � ` " ( W6 - / 4 , 6 G Date: l� �O PG07 -043 Printed: 04 -06 -2007 p SITE LOCATION King Co Assessor's Tax No.: Site Address: a60 Ewa S / Q'P "� �+� 9� Suite Number: Floor: Tenant Name: � f'/ � L0 /2. New Tenant: ..Yes ❑..No � L C Property Owners Name: C4Ll✓ES I i'Sri2/ /4t h 0G/,/�t4 .?, L Mailing Address: CONTACT PERSON — who do we contact when your permit is ready to be issued Name: t�/ / C, CM-PP-6: Day Telephone: l/ ?S - 3 S 3 - 94/ 47? Mailing Address: ?VC) // zIi SX •S, tv • i 5 W7 I Z nV /2E1t- 14, e 20 City State Zip E -Mail Address: cyloce) i>4641/44 Ceizscr-) 4ti7S .C"44 Fax Number: V 2 )S3 3 GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg S)) Company Name: - Phi u1 4 Z /i0 57—/E'S ,/ Mailing Address: ,?O 4 74/? 'ACT 74S r- 5) •) Q&) Me mo t. W7`- • C7 3 City State zip Contact Person: re) I' 1714-NS0 '✓ Day Telephone: V ?-5 - - 7 7 ' 2. E -Mail Address: j7%our i 15 -C6vv. Fax Number: t {2. - 840 CS — g Contractor Registration Number: 7#o 1 ,ATS 07? P 7 Expiration Date: 0 S - ? ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Zip Contact Person: E -Mail Address: ENGINEER OF RECORD - All plans . must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q:Mpplications\Fomu- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bb CITY OF TUKWII& Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hum: //invw.ci.Tukwila.wa.us Building Perno. Mechanical Permit No. /1 ?fro-- Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** City i2. —ot State State City Day Telephone: Fax Number: State Zip Zip Page 1 of 6 BUILDING PERMIT INFOlr 4TION - 206- 431 -3670 Valuation of Project (contractor's bid price): $ Existing Building Valuation: $ Scope of Work (please provide detailed information): Will there be new rack storage? ❑ Yes ❑ .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Is Floor 2a ° Floor 3 Floor Floors Basement Accessory; Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck Interior Remodel Addition to Existing Structure Type of Construction per MC Type of Occupancy per IBC Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: D FIRE PROTECTION/HAZARDOUS MATERIALS: R " yf 5v& //Tre '2p 7i 7 4 ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None la Other (specify) Q:1Applications\Ponns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 PUBLIC WORKS PERMIT IN RMATION - 206 -433 -0179 Scope of Work (please provide detailed information): Water District ❑ ...Tukwila ❑ ...Water District #I25 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill Please refer to Public Works Bulletin #1 for fees and estimate sheet. cubic yards cubic yards ..Sanitary Side Sewer ..Cap or Remove Utilities ..Frontage Improvements ..Traffic Control ..Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public _ ❑ ...Water Main Extension Public _ ❑ ... ValVue ❑...Sewer Availability Provided „ „ „ ❑ . ❑ . ❑ . ❑ . . Abandon Septic Tank . Curb Cut . Pavement Cut . Looped Fire Line „ Q:1Applieations\Forms- Applications On Line13 -2006 - Permit Application.doc Revised: 9 -2006 Call before you Dig: 1-800- 424 -5555 ❑ .. Highline ❑ .. Renton ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ .. Renton ❑ .. Seattle ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding WO # WO # WO # ❑...Deduct Water Meter Size Private Private ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) , , FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter RefundBillinp: Name: Mailing Address: Day Telephone: City State Zip Page 3 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System ■ ood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent _...s—... Hood and Duct Emergency Generator 50+ HP/1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator - Comm/Ind MECHANICAL PERMIT IN ZMATION- 206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: TM; 04/1-'3. SJ-/ E - Mailing Address: a-05 Y ' - 4 5 . 7 $7. I Contact Person: � /`O "- /fi/t A/.9'1../ E -Mail Address: 71)43 146 43 / A+) ( $IS Ai-cc:7\ ^ Contractor Registration Number: 77ki 14f 4.27' O 72- / q Valuation of Mechanical work (contractor's bid price): $ i /C; (' au Scope of Work (please provide detailed information): 7) 3 MZC D1444 sbe4/ AU 4 121 4i/2 o1/4 ° , 7 Use: Residential: Commercial: New .... ❑ Replacement .... ❑ New ... Replacement .... ❑ 2679Ieo, w4. q -os City State Zip Day Telephone: if 2 S ' D(o D 77/ Z Fax Number: V Lam' 86 SC - 156q Expiration Date: /D kr 0 Fuel Tvpe: Electric ❑ Gas .. Other: Indicate type of mechanical work being installed and the quantity below: Q:Npplications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 4 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPINIERMIT INFORMATION - 206 - 431 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: / /Y" v S /6 Z/ n ,.,, Mailing Address: 20e7 4 Z Nt b ' 7c6 S7`' l NU)- t4 Lv4 er ISO S 3 Contact Person: 77) 141 #4 N.SD 1) E -Mail Address: Thin Lst 2 fl?_SN Cdw Contractor Registration Number: 'h.U}l. 7 Z Ag Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): ci 4fA 2 / 7 ICA� /i' i 141 9lln A&' PPG/ Q: ApplicationsWonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh i //ts,/ /Ar 62 >4 Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: City Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: State Zip Day Telephone: 4 L 3' g'b6 77V Fax Number: 1/ ?'.S ' $455 — Keg' Z Expiration Date: /6 / S' CO 7 Sewer: Page 5 of 6 PERMIT APPLICATION N S — Applicable to all permits in this a lication Signature: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Print Name: /2 4 1 Date: G-7 ' 7 Day Telephone: ¥ t S 35'3 ZS Mailing Address: 3/ // 21 •=3J` • S 4 SUIT) 3? / %21 `P7 4' irg y City State Zip Date Application Expires: a t04 Date Application Accepted: D 0,14c4 Q: Applications\Fonns- Applications On Line V-2006 - Permit Application.doe Revised: 9-2006 bh Staff Initials: ( Page 6 of 6 Parcel No.: 2523049015 Address: 960 INDUSTRY DR TUICW Suite No: Applicant: B & K TAYLOR Receipt No.: R07 -00522 s - City of Tukwila Payee: MANUFACTURERS' AGENTS NW INC TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description GAS - NONRES Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Initials: LAW Payment Date: 04/06/2007 11:18 AM User ID: 1632 Balance: $0.00 Amount Payment Check 11421 88.00 Account Code Current Pmts 000/322.100 88.00 Total: $88.00 Permit Number: PG07 - 043 Status: APPROVED Applied Date: 02/07/2007 Issue Date: Payment Amount: $88.00 doc: Receiot -06 Printed: 04-06 -2007 Doc: RECSETS-06 RECEIPT NO: R07 -00177 Initials: User ID: ) 1165 Payee: MANUFACTURERS' AGENTS NW, INC SET ID: 0207 SET NAME: B & K TAYLOR SET TRANSACTIONS: Set Member Amount City • Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431 -3665 Web site: http: //www.ci.tukwila.wa.us M07 -029 135.51 PG07 -043 22.00 TOTAL: 157.51 TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES SET RECEIPT 000/345.830 TOTAL: Payment Date: 02/07/2007 Total Payment: 157.51 Amount Payment Check 11154 157.51 TOTAL: 157.51 Account Code Current Pmts 157.51 157.51 Project: / IF , e 7- 4y 4 r- Type of Inspection: ,C74/ 4' /— 0 9 C Address: Date Called: — Special Instructions: Date Wanted: / — I -7- e fri: Requester: Phone No: z,/z. - 7 5• -s INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1 6300 Southcenter Blvd., #100, Tukwila, WA 98188 / (206)431-3 7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 'Date: 0c F s ," Inspeor:N $58.00 REINSPECT! N FEE EQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: COMMENTS: ('1k Address: 9 Q TNo s -r' D2 4 o:I 1 (J/lE W .U. a. i dl: r/1 G AA 'p'A_ Xe 0. � ;I 1 i i - A') a.m. p :ni s (f 11 4J_ / £ .f / /7,_t ` p / __4V4 4v - r (e -Sc h - . ,_ - ..- � _ Project IC ( 'Al + v � Type of Inspection: • •,t//} —, . 64J f' :P, 4 Address: 9 Q TNo s -r' D2 Date Called: Special Instructions: Z� ' AC 4 P.t p c ��� /4 e', it ru - -) p un,T Date Wanted: / -- /r -QS a.m. p :ni Requester: Phone Phon ('' / -gi733 (� INSPECTION RECORD 0 ` Retain a copy with permit rG / 7 J INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Approved per applicable codes. El Corrections required prior to approval. (Inspector 1 Date: 11 'OS" mot $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule 'reinsp fiction. 'Receipt No.: 'Date: Proje t: ; 4�rLv� Type of Inspection: � /9 -, ,L.i � \ &,/ S Address: , /= fT( 617 Date Date Called: Special Instructions: Date Wanted: 7 - 7 Q 7 a :1 p.m. Requester: Phone No: ` 1 2 - S— 2 5 1 - / z S INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: El $58.00 REIN CTION FEE REQUIRED. Prior to inspection. fee must be paid at 6301 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: pproved per applicable codes. ❑ Corrections required prior to approval. lab (206)431 -3 1/ 12 -11 -2007 CHUCK GILLETTE 2310 112 ST SW, STE B2 EVERETT WA 98204 RE: Permit No. PG07 -043 960 INDUSTRY DR TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the Uniform Plumbing Code and/or International Fuel Gas Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Plumbing and/or Gas Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 01/20/2008 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Ter Marshall, it Technician xc: Permit File No. PG07 -043 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DEPARTMENTS: u I ini 'Divisi n B Public Works Complete Comments: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG07 - 043 DATE: 02 -07 -07 PROJECT NAME: B & K TAYLOR SITE ADDRESS: 960 INDUSTRY DR X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU NG: Please Route len Structural Review Required REVIEWER'S INITIALS: ❑ ❑ Permit Coordinator No further Review Required DATE: DATE: Planning Division C DUE DATE: 02-08-07 Not Applicable ❑ n DUE DATE: 03-08-07 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Q 15' WIDE c DRAINAGE _ . k UTILITY EASEMENT N ; NO1•47'28'E j i 18.00 \ i 15' WMOE _ UNITY EASEMENT 90' 9 ° 0 to n fr _1 OS Z z r 0 i LEGAL DESCRIPTION I 1 f PARCEL 1 O 31 b O BLDG. 28 23.858 SO. TT. C) 50' WIDE SETBACK 904 •2.S - - - • 43 0 15' WIDE SETBACK 2 T__J :b3 • • c •J • • • • 15' WIDE SETBACK r: N01'47'28'E 430.00 • 1 SITUATED IN THE SOUTHWEST QUARTER OF SECTION 25, TOWNSHIP 23 NORTH. RANGE 4 EAST, WILLAMETTE MERIDIAN, CITY OF TUKWILA. KING COUNTY, WASHINGTON, AND BEING DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE CENTERLINE OF A PRIVATE ROAD, ALSO KNOWN AS INDUSTRY DRIVE. SAID POINT BEING SOUTH 014728' WEST. A DISTANCE OF 90.48 FEET AND SOUTH 88'12'32' EAST, A DISTANCE OF 127.16 FROM THE WEST QUARTER CORNER OF SAID SECTION 25 ANO RUNNING THENCE SOUTH 88'12'32' EAST. A DISTANCE OF 291.50 FEET TO A POINT ON THE WEST RIGHT -OF -WAY UNE OF JAMES CHRISTENSEN ROAD NO. 1479; THEME FOLLOWING SAID WEST RIGHT -OF -WAY LINE THE FOLLOWING COURSES: SOUTH 3239'25' WEST, A DISTANCE OF 96.43 FEET; THENCE SOUTH 20`16'2&• WEST. A DISTANCE OF 114.09 FEET; THENCE SOUTH 03'06'25' WEST A DISTANCE OF 122.73 FEET; THENCE SOUTH 0241'35' EAST. A DISTANCE OF 98.54 FEET; THENCE SOUTH 1963'35' EAST, A DISTANCE OF 168.88 FEET; THENCE SOUTH 32`38'35' EAST, A DISTANCE OF 158.24 FEET; THENCE SOUTH 44'38'35' EAST. A DISTANCE OF 25.37 FEET TO A POINT; THENCE LEAVING SAID WEST RIGHT -OF -WAY LINE AND RUNNING SOUTH 0147'28' WEST, A DISTANCE OF 461.42 FEET; THENCE NORTH 88x1732' WEST. A DISTANCE OF 254.00 FEET TO A POINT ON THE EAST TERMINUS LINE OF 11NNlKLER BLVD.; THENCE NORTH 01'4728' EAST. ON SAID TERMINUS LINE A DISTANCE OF 18.00 FEET TO THE NORTHEAST CORNER OF SAID MSNKLER BLVD. AND BEING ON THE NORTH RIGHT-OF-WAY UNE THEREOF, SAID POINT ALSO BEING 46.00 FEET FROM THE CE)N1TUtINE; THENCE NORTH 88'12'32' WEST, ON SAID NORTH RIGHT- OF-WAY LINE A DISTANCE OF 103.00 FEET TO A POINT ON THE CENTERLINE OF A PRIVATE DRIVE THENCE ON SAID CENTERLINE THE FOLLOWING COURSES: NORTH 0147'28' EAST. A DISTANCE OF 430.00 FEET TO THE BEGINNING OF A TANGENT 26000 FOOT RADIUS CURVE LEFT; THENCE ON SAID CURVE THROUGH A CENTRAL ANGLE OF 1149•33' (THE LONG CHORD OF WHICH BEARS NORTH 0t0719' WEST, A DISTANCE OF 77.47 FEET) AN ARC DISTANCE OF 77.78 FEET TO THE END THEREOF AND THE BEGINNING OF A TANGENT 250.00 FOOT RADIUS CURVE RIGHT; THENCE ON SAID CURVE THROUGH A CENTRAL ANGLE OF 17''4933' (THE LONG CHORD OF WHICH BEARS NORTH 07'OT1 - WEST. A DISTANCE OF 77.47 FEET) AN ARC DISTANCE OF 77.78 FEET TO THE END THEREOF; THENCE NORTH 01'47'28• EAST. A DISTANCE OF 577.17 FEET TO THE POINT OF BEGINNING, CONTAINING 7.783 ACRES MORE OR LESS. BASIS OF BEARING BEING THE CENTERLINE OF STRANDER BLVD. PER SURVEY NO. 8704029002. BLDG. 26 1. 12.400 SO. FT 4 • ' 96 i- S01'47'28'W 46142 I6 20' WIDE INGRESS & EGRESS EASEMENT . 11 4 I. I • X BLDG. 24 16.671 SO. F' • 7 Z. 9 i J r J ' b 0 .1 :'a l' 13' N =250 W A : ;7 78 a=s07 0719 .. .77 47 BLDG. 22 - 19 200 SO Ft A :317 k .?5000 A=77 ;0=507'07'19T =7747 • 3 • 0 20' WIDE NON - EXCLUSIVE ACCESS EASEMENT 2 • INDUSTRY DRIVE 0 i, a VICINITY MAP .I'.:, I 1.•':L ` -: M ! * :'Ji r UANQhtl1 f . aE -•ii•'a.Y' 99 rER LIFTER E.T,51r VAN;[ ,a3 urE TER -4 4&.( AP PAR,- n .1•` ?rN.r41_ P ;:t NITER ;A *..."A•p Poi' . •:. u :,y ., N , (1) 20' WIDE 1 INGRESS & EGRESS I EASEMENT LEGEND R I V E R r • 50' 50 25 0 50 100 1 401'47'78 - E 57' 17 O ri 1 : :3 06 - * 122 73 SPRAY SYSTEMS STD. DESIGN FEATURES BOOTH CONSTRUCTION PANELS ARE MANUFACTURED OF 18 GA. GALVANMZED STEEL ALL PANE! S HAVE PEED HOLES FOR EASY NIT & BOLT ASSEMBLY. BOTH THE FLIER AND SOLID TYPE DOORS NAVE A STRUCTURAL STEEL TUBE FRAME, LEM PROOF WIPER TYPE SEALSATTNE BOTTOM & POLYFOAY SEALS ATTHE CENTER &JAMBS. LIGHTING HIGH EFACENCY UGHTING UNITS DESIGNED FOR NOUN= OUTSIDE BOOTH. SET IN FRAMED WIRE GLASS OPENINGS, HAVE DUST TIGHT SEALS &ARE UL USED. FAN SPECIFICATIONS DESK FOR SPRAY BOOTHS. HEAVY DUTY TUBEAAAL TYPES= ENCLOSED BELTS& BALLBEARIG&. MOTORS ALL MOTORS ARE BIERGY EEfCEiNT, TOTALLY EIICLOSEO, FM COOLED, MUL1WOLTAGE, 21Rf23W4601HREE PHASE NTH SINGLE PHASE OPTION. FILTER GAUGE A MANOMETER IDICATES WEEK PAINT ARRESTORS OF DIME RUBIS IM RE RNPLACSIENT. EXHAUST FILTERS DISPOSABLE WIT ARRESTOR EXHAUST AR R.TERSARE ASPECIALLYSIIIIN FUR DESIG EDTORE10WEPANT PARTICLES E fIOENTLYFROMSPRAT BOOTHECHAINSTAR UL LISTED ELECTRICAL COIOIETS A1ID lA OW= UL LISTED. SINESUPFRESSOMPRIVIER MEI POW NIL BE APP FOR ATA LATMAITE6TVE IESIVIVROINSTAIIANDIF corm. nos IRK WA Di SOINITTAL 15' WIDE •- SETBACK GENERAL NOTES C) 15' WIDE SETBACK S4, N 15' WIDE SETBACK ALL SPRAY BOOTHS & M1ONG ROOMS SHALL CONPLY WITH 2003 NTERNATION BUILDING CODE & ALL LOCAL CODES INCLUDING FIRE CODES. 1. ©ONTRACTOR SHALL FIELD VERIFYALL LOCATIONS & 1EASUREMENTS, ANY DISI REPANCES FOUND CONTACT OWNER & OR DESIGNER IMMEDIATLY. 2. ELECTRICAL WIRING SHALL COMPLY WUH NBC WIRING CODE. 3. ALL METAL PARTS OF THE SPRAY BOOTIN, MOTORS, EXHAUST DUCTS &PIPING SHALL BE ELECTRICALLY GROUNDED 4. ELECTRICAL WIRING & EQUWIIEIR IN SPRAY BOOTH & VAPOR AREASSHALL BE OF AN EXPOSION -PROOF TYPE FOR USE IN SUCH HAZORDOUS LOCATIONS. S. OPEN FLAMES &SPARK - PRODUCING DEVICES SHALL NOT LOCATED ON SPRAY OR VAPOR AREAS & SHALL NOT LOCATED W THIN 20 FT OF SUCH AREAS. 6. EQUIP ENTORAPPARABJS TWIT IS CAPABLE OF PRODUCING SPARKS OR PARTICLES OF HOT METAL WOULD FALLINTOSPRAYBOOTH OR VAPORAREASHALLBE TOTALLYENCLOSED. 7. SMOKING SHALL BE PROHIBITED IN SPRAY BOOTH OR VAPOR AREAS. 'N0 SMOKING SIGNS SHALL BE CONSPICUOUSLYPOSTED N SUCH AREAS` L COMBUSTBLE FLOORN SPRAYING AREAS SHALL BE DOWERED BY AFFRONTED; NONCOMBUSTIBLE, NON SPARRING WARM, EXCEPT WHERE COMBUSTIBLE COVERWGS,SUCHASUIN PAPER OR PLASTIC AND STRIPPABLE COATINGS ARE UUI2ED OVER NONCOIBUTIBLE MATERIALS TO FACT ?ATE CLEANING OPERATIONS IN SPRAYINGAREAS: 9. SPRAYSISPRAY ROOMS & SPRAYAREAS SHALL NOTAUERNATELY UTIQED FOR DIFFERENT TYPES OF COATING MATERIALS WHERE TIE COMBINATION OF MATERIALS IS COIDUCTME TO SPONANEOUS IGNITION, UNLESS ALL DEPOSITS OF ONE WHEW. ARE REMOVED FROM THE BOOTH, ROOMORLEA& COIAUST DUCTS PRIOR 10 SPRAYING INDIA DEFERENT MATERIAL ILIUM SPRAYING AREAS, SPRAY ROOMS OR SPRAY BOOTHS ARE LLU HATED THR000H GLASS PANELS OR OTHER TRANSPARENT MATERIAL S,ONLYFDALIGHTING WITS SNAIL BE UMMEDASA SOURCE OF ILWMINNATION. it SPRAY BOOTHS & MDWGROOMSSHALL BEAIICIIOREDTOTHE FLOOR AT LOCATIONS PROVIDED BY A IIIFACIIRIE. 1L BOOM DOLA1STSSHALLE) DWAlIST6FTIN !ABOVE ROOF &WFTMINFROMPROPERTYLBO. 13. rEciunCALVBITRATION OF SPRAYING ARES SHAD. BE PROVED R ACCORR1ANCE WITH INTERNATIONAL IENOWICAL 14. VBTRAIIONSHALLBEAINOF30FTFROM PROPERTY WES & OFTFROM FRONOPENINGSRITO BMDING, 6 FT FROD WALLS AND ROOFS. IS. ARRESMAGUISIIR CLASS C, 4A SHILL BE PROVIDED W I WI 7S FT MAX SPRAY BOOTHSPECS It SPRAYSTSTEI SPRAY BOOTH M BIM.TNA000RQRUICENITH NFPA 33,FC,1iEC, BC„ MIC. 17 TIESPRAYBOOTH ISOONSTRUCEDOF ROE 18GAUGEHOTNPED IL FM BELISOONOT EM1 TIE HOUSRIG, DUCT OR BOOTH. it TI ENMEI80RSURFACEOFTESPRAY800THM1.OESMMOTH &CONTMUOUSIMIOUTEDGES. 21. UGNTiRTIRBS ML BE 4 TUBE RUORSCEl1T, OPEN WPE SEALED FROM gJISDE OF THE SPRATOOODI 88120110 SAF EWYGUS& 21. TIE SPRAYBOOTHHASHAVISINEL7QUID17 TW. ARGAQGE(6AMONETEEFOROOIAUIVTFMLTEIR RERACEEIMITINARIMIG. 21 THEED IM15T RUMPLE/Oa LILOCATEDpITIEBAOLOFT)ESPRATBOOTH. THE MAST FIfTT3T3ai COOKY=TH 000EE STS IDA 33, INOE NIRT LDS, MC.1114 E MVlORMENFALAGENCY PAT; SAFETY& IEALN ASSOCIATION( IDS/SSW UMW. a ENIRAUST CULTISM' ERIN$6AUGE . & COMPLIEa 1HIH NC. 24. TIEREAIE NO BENDSINUE ELHAUSTOUCTGREATERTHANAMEGREEMOLE Z. TIE EDWAINSTD ETi .LMVEAOREMO1RFORCIEM G&IISPECiiOt 2L OOMPRTSSEDARtTOOPETd1TE "RAT WSW II DEOFTHESPRAYBOOTHITN .BERITERLOCIEDWIN ELIWAITFIVESPRATE ursei1IALl TOPERATEWTHOUTTMESPRATSOOTR1iB0EDOR. V. RAM & SPionmTc13 FOR TIE DESIGN & INVOLUTION OF TIE FIE 9,P ON maims THE 800MR11NRLL IE SUBMITTED B7 OTHERS. PILE COPY Permit No. Plan reV.ew approval Is subject to errors and omission& Approval of c:nsbuctlo.n dxcumcnts does not authorise the violation cf cny c d cr ordlnanc3• Receipt Of approved r_: ; r .I ccri : y ^ ^r; 13 acknowledged: By bate: City of Tljkwlla BUILDING DIVISION B the cope C � _3*! jes shalt be made the Cl - --- without prior opprosmi l4 rCge re ,,, 'Ore. T'�',:'V'u.O11S ,�i � i;+l'.^.:f t.,eS. -;eel may include additional p�ca PAGE DIRECTORY: s SEPARATE PERMIT r:: .IZRED FOR: ▪ Mechankal ReC' rkai O I um5ing © Gels Pip'ng City of '�Lkwffa BUILDING DMSIoN REVIEWED NE CODE CO Pik -- 4 249 C t - cl! � ��ICTN PROPERTY OWNER: CIO EPROPERTYTAX INC. 800 INDUSTY DR. TUKWILA, WASH. 98188 BUSINESS: WHOLESALE SIGN SOLUTIONS ADDRESS: 960 INDUSTRY DR. TUKWILA, WASH. 98188 LEASING COMPANY: RREEF SR. LEASING PROP. MANAGER: CONNIE DOBBS 631 STRANDER BLVD., SUITE G TUKWILA, WASH. 98188 PHONE 206675-0765 PARCEL NO.: 2523049015 PROPERTY DESCRIPTION: SEE PLOT PLAN ON PAGE A01 PROJECT DESCRIPTION: 1. INSTALL A PARR BOOTH. 2. NO CHANGES TO FOUNDATION, NO EXCAVATION REQ'D, NO CHANGES TO BLDG SPACE. 4. E GIAUST GOES STRAIGHT UP THRU ROOF & THEN ALONG ROOF TO A POINT THAT IS A MIN. OF 30'.' FROM PROPERTY LINES AND MIN OF 6'41' ABOVE ROOF. 5. PART BOOTH, MIXING ROOM & AIR MAKE UP TO BE ATTACHED TO EXISTING CONCRETE FLOORS PER DETAIL 1 IA 01 A PLOT PLAN, PROPERTY DESCRIPTION, GENERAL NOTES, A at DETAL PLANS & SECTIONAL ELEVATION 40 PROJECT PLAN r t Z z X W 2 CO3 ^ a i u12 z O ea W O V H d= B E I S tri z c I S • d 49 • • a wal 10 awl 0 ig 0 40'4" r r i d y g '0 C) e �0 v xi Ni 0O CO 00 0 77 > 950 O VERIFY ROOF HEIGHT •--- 8' - 0.0. --�I T p p T i !IF 1 •-_ 8'-5" O.D. ---- �-- 7 - 9" I.D. 7 -9" D.O. -- cn -co i s 2 11 310" I . I � I 9 11 —1--ar till 1 •-- 9 -0" O.D. --- r 7 -6" I.D. 952 rdp 16 954 1 0 16'4' I 180'-0" 956 958 15'•0" THOMAS INDUSTRIES, INC. 20942 N.E. 78 TH STREET REDMOND, WASH. 98053 PH: 425.8684142 FAX 425.8688692 LICENSE 9 THOMA11072P9 EXP,10.07 cv) rn n r > rn 1 C rn > —44 11 C m 4E2 3" DEEP HOLE w! 318" 0 ANCHOR BOLT rre 6") I - • •- ' 960 0 0 ; ; I; 30' -0" r J 24' -0" O.C. TYPICAL B & K TAYLOR WHOLESALESIGN SOLUTIONS 960 INDUSTRY DR. TUKWILA, WASH. 98188 -r 31'-6" m m 964 962 19'-8" 6%0" MIN ABOVE ROOF I' TERRY DESIGNS 18894 NE 106TH ST REDMOND, WAS. 98062 4258814079 FAX 4702.0369 tony®tKryhom.dalgno CERTIFIED PROFESSIONAL BUILDING DESIGNER TERRY PARK 2.06.07 NATIONAL COUNCIL OF BUILDING DESIGN CERTIFICATION