HomeMy WebLinkAboutPermit PG07-051 - TULLY HOMES - LOT 2TULLY HOMES
LOT 2
16030 51 AV S
PGO7-05 1
Parcel No.:
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
Contact Person:
Name:
Address:
5379200066
16030 51 AV S TUKW
TULLY HOMES, LOT 2
16030 51 AV S , TUKWILA WA
TULLY HOMES INC
13217 4 AV SW , BURIEN WA
DALE HODSON
811 W STEWART , PUYALLUP WA
Contractor:
Name: SUNRISE ENERGY SYSTEMS
Address: 811 W STEWART AV , PUYALLUP WA
Contractor License No: SUNRIES096K3
DESCRIPTION OF WORK:
INSTALLATION OF (5) GAS PIPING OUTLETS
Value of Plumbing /Gas Piping: $675.00
Fees Collected: $88.00
Plumbing
Bathtub or combination bath/shower 0
Bidet 0
Clothes washer, domestic 0
Dental unit, cuspidor 0
Dishwasher, domestic, with independent drain 0
Drinking fountain or water cooler (per head) 0
Food -waste grinder, commercial 0
Floor drain 0
Shower, single head trap 0
Lavatory 0
Wash fountain
Receptor, indirect waste 0
Sinks 0
Urinals 0
Water Closet 0
doc: UPC -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www. ci. tukwila. wa. us
PLUMBING /GAS PIPING PERMIT
FIXTURE TYPE AND OUANTITY
0
* *continued on next page **
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 253 221 -7651
Phone: 253 445 -0622
Expiration Date: 01/03/2009
Steven M Mullet, Mayor
Steve Lancaster, Director
PG07 -051
02/14/2007
08/13/2007
Uniform Plumbing Code Edition: 2003
International Fuel Gas Code Edition: 2003
Plumbing (cont.)
Building sewer and each trailer park sewer 0
Rain water system - per drain (inside bldg) 0
Water heater and/or vent 0
Industrial waste treatment interceptor, including
its trap and vent, except for kitchen type
grease interceptors 0
Repair or alteration of water piping and/or water
treatment equipment 0
Repair or alteration of drainage or vent piping 0
Medical gas piping system serving (1 -5)
inlets /outlets for a specific gas 0
Medical gas piping (6 +) inlets /outlets 0
Gas Piping
Gas piping outlets (0 -5) 5
Gas piping outlets (6 +) 0
PG07 -051 Printed: 02 -14 -2007
Permit Center Authorized Signature:
I hereby certify that I
governing this work
The granting of
construction or
Signature:
Print Name:
doc: UPC -10/06
permi
perfo
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
read and
e c mplie
�, I .
lif 4'01
_\, M C
Date: tY2-j1hj 14'
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
esume to give authority to violate or cancel the provisions of any other state or local laws regulating
rk. I am authorized to sign and obtain this plumbing /gas piping permit.
Permit Number: PG07 -051
Issue Date: 02/14/2007
Permit Expires On: 08/13/2007
Steven M Mullet, Mayor
Steve Lancaster, Director
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PG07 -051 Printed: 02 -14 -2007
Parcel No.: 5379200066
Address:
Suite No:
Tenant:
doc: Cond -10/06
16030 51 AV S TUKW
TULLY HOMES, LOT 2
1: ** *PLUMBING AND GAS PIPING * **
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
* *continued on next page **
Permit Number:
Status:
Applied Date:
Issue Date:
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
PGO7 -051
ISSUED
02/14/2007
02/14/2007
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
PG07 - 051 Printed: 02 -14 -2007
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be co - - d with, whether specified herein or not.
The granting of
construction or
Signature:
Print Name:
doc: Cond -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
pe t does • presume to give authority to violate or cancel the provision of any other work or local laws regulating
•ep.. ork.
Date -V %
• �?
PG07 - 051 Printed: 02 -14 -2007
Site Address: (( 030 4 I r A#C. SO
Tenant Name:
Property Owners Name: TA( I
Mailing Address:
Name:
Mailing Address:
E -Mail Address: C:V OCI.C[l.\. +1 1 t(A., 1
Company Name: < (A ∎i
Mailing Address: I \ ,f
city
Contact Person: � . l(CISCN■ Day Telephone:
E -Mail Address: S GtAn v St P S LA) t f , wet- Fax Number:
Registration Number: S � N
Contractor Re Expiration Date:
g I � d � / p
3
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
CITY OF TUKWILA,
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
/- 153,407.v-
Q: Q: Applications\Forms- Applications On Line' -2006 - Plumbing -Gas Piping Permit Application.doc
Revised: 4-2006
bh
King Co Assessor's Tax No.: $X 1 637? 2d,0
Suite Number: Floor:
New Tenant: El .... Yes El ..No
Piumbing/Gas Permit No.
Project No.
(For o ice use only)
City
City
Fax Number:
s42.vvt, S
State
CONTACT PERSON -Who do we contact when your permit is ready to be issued
Day Telephone: 2 C7 221 ! W $7
State
PLUMBING / GAS PIPING CONTRACTOR INFORMATION
State
State
. ZiP
Zip
': t2 l 7 ' )
/ 7 3 / 2 &3
Company Name:
Mailing Address:
city
Contact Person: Day Telephone:
E -Mail Address: Fax dumber:
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
city
Day Telephone:
Fax Number:
Zip
Page 1 of 2
Fixture Type:"
Qty
Fixture Type:
Qty
Fixture Type:'
Qty
Fixture Type :.
Qty
Bathtub or combination
bath/shower
Drinking fountain or water
cooler (per head)
Wash fountain
Gaspiping outlets
5
Bidet
Food -waste grinder,
commercial
Receptor, indirect
waste
Clothes washer, domestic
Floor drain
Sinks
Dental unit, cuspidor
Shower, single head trap
Urinals
Dishwasher, domestic,
with independent drain
Lavatory
Water Closet
Building sewer or trailer
park sewer
Rain water system — per
drain (inside building)
Water heater and/or
vent
Additional medical gas
inlets/outlets — six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water treating
equipment
Repair or alteration
of drainage or vent
piping -
Medical gas piping system
serving one to five
inlets/outlets for specific gas
Valuation of Project (contractor's bid price): $ ( ZLt+t . (1 � Zc
Scope of Work (please provide detailed information):
Building Use (per Intl Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable caused strated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY C
PENALTY OF
BUILDING 0
Signature:
Print Name:
Mailing Address:
I Date Application Accepted:
HAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
WS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
ED AGENT:
C i L Z . <'/l
� -�
gt\ w� -s`� s-{- . fir
crLl tctli/D11/4-
Q:Wpplications'Forms- Applications On Line\3 -2006 - Plumbing -Gas Piping Permit Application.doc
Revised: 4-2006
bh
Date Application Expires:
City
D TA 1 j ; -
Telephone:
State Zip
Staff Initials:
Page 2 of 2
RECEIPT NO: R07 -00225
Initials: JEM
User ID: 1165
SET TRANSACTIONS:
Set Member Amount
Doc: RECSETS -06
ACCOUNT ITEM LIST:
Description
GAS - RES
MECHANICAL - RES
PLAN CHECK - RES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: //www.ci.tukwila.wa.us
Payee: SUNRISE ENERGY SYSTEMS
SET RECEIPT
Payment Date: 02/14/2007
Total Payment: 323.00
SET ID: 0214A SET NAME: TULLY HOMES, LOT 2
M07 -036 235.00
PG07 -051 88.00
TOTAL: 323.00
TRANSACTION LIST:
Type Method Description
Amount
Payment Check 23616 323.00
TOTAL: 323.00
Account Code Current Pmts
000/322.100 88.00
000/322.100 194.00
000/345.830 41.00
TOTAL: 323.00
Project:
: zee /.. --
Type of Inspection:
..,900
10 . / ,...
Addres :
i 7;0 _S
Date Called:
."
Spe i. nstructions:
— •
Date Wanted:
a.m.
p .m.
.---
Requester:
Phone No:
LI
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Approved per applicable codes.
•
PERM
(206)431-36 0
Corrections required prior to approval.
COMMENTS:
ZI_
c/o
Inspector: s, Date:
Alp 7
$58. EINSPECTION FEE EQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
'Receipt No.:
'Date:
dek
Project:
'v l et t e
Type of Inspecti
Addre Z ox 5/
S ,
Date Called:
Special Instructions: •
646 774
Date Wanted:
a.m.
p.m.
Requester:
Phone No:
7&7 -o5/
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Sou thcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Approved per applicable codes. ❑ Corrections required prior to approval.
COMMENTS:
Inspector:
I Date : / / 7
$58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
(Receipt No.:
'Date:
Projec •
..A �, %
■
Type of Inspection:
L ' //l AI ;
Al' �
. Address:
■
Date Called: / _ 0
Special Instructions:
Date Wants_
J----07 .
Requester:
Phone NQ.;_
5.32j , /c/
INSPECTION NO. , PERM
CITY OF TUKWILA BUILDING DIVISION 't
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -
pproved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
Corrections required prior to approval.
COMMENTS:
Date:
ri $58.00 REIN CTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
'Receipt No.:
'Date:
License Information
License
SUNRIES096K3
Licensee Name
SUNRISE ENERGY SYSTEMS
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
601294462
Ind. Ins. Account Id
Business Type
CORPORATION
Address 1
811 W STEWART AVE
Address 2
City
PUYALLUP
County
PIERCE
State
WA
Zip
98371
Phone
2534450622
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
5/23/1991
Expiration Date
1/3/2009
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
HODSON, JOHN J
01/01/1980
HODSON, DALE E
01/01/1980
WHITE, JANICE R
01/01/1980
Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
STATE
FARM
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date