HomeMy WebLinkAboutPermit PG07-069 - PERKINS RESIDENCEPERKINS RESIDENCE
14229 55 AV S
EXPIRED 09 - 18 - 07
PG07 -069
Parcel No.:
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
Contact Person:
Name:
Address:
doc: UPC - 10/06
0761000170
14229 55 AV S TUKW
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERKINS RESIDENCE
14229 55 AV S , TUKWILA WA
PERKINS DANIEL H +DEBORAH JO
14229 55TH S , SEATTLE WA
MELISSA CRODA
1345 GULF RD , POINT ROBERTS WA
Contractor:
Name: WASHINGTON ENERGY SERVICES CO
Address: 2800 THORNDYKE AVE W , SEATTLE, WA
Contractor License No: WASHIES9710B
DESCRIPTION OF WORK:
REPLACE 50- GALLON GAS WATER HEATER
Plumbing
Bathtub or combination bath/shower 0
Bidet 0
Clothes washer, domestic 0
Dental unit, cuspidor 0
Dishwasher, domestic, with independent drain 0
Drinking fountain or water cooler (per head) 0
Food -waste grinder, commercial 0
Floor drain 0
Shower, single head trap 0
Lavatory 0
Wash fountain
Receptor, indirect waste 0
Sinks 0
Urinals 0
Water Closet 0
PLUMBING /GAS PIPING PERMIT
Value of Plumbing /Gas Piping: $950.00
Fees Collected: $88.00 International Fuel Gas Code Edition:
Uniform Plumbing Code Edition: 2003
FIXTURE TYPE AND OUANTITY
0
* *continued on next page **
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 360 945 -2787
Phone: 206 282 -4200
Expiration Date: 09/02/2007
Steven M Mullet, Mayor
Steve Lancaster, Director
PG07 -069
03/22/2007
09/18/2007
2003
Plumbing (cont.)
Building sewer and each trailer park sewer 0
Rain water system - per drain (inside bldg) 0
Water heater and/or vent 1
Industrial waste treatment interceptor, including
its trap and vent, except for kitchen type
grease interceptors 0
Repair or alteration of water piping and/or water
treatment equipment 0
Repair or alteration of drainage or vent piping 0
Medical gas piping system serving (1 -5)
inlets /outlets for a specific gas 0
Medical gas piping (6 +) inlets /outlets 0
Gas Pipina
Gas piping outlets (0 -5) 0
Gas piping outlets (6 +) 0
PG07 -069 Printed: 03 -22 -2007
Permit Center Authorized Signature:
Signatur
doc: UPC -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
UU7
Permit Number: PGO7 -069
Issue Date: 03/22/2007
Permit Expires On: 09/18/2007
Steven M Mullet, Mayor
Steve Lancaster, Director
Date: 6
I hereby certify that I have read and eam4ned this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied , whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance o - . am authorized to sign and obtain this plumbing /gas piping permit.
Date:
Print Name: 130 0..j \A
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PG07 -069 Printed: 03-22 -2007
Parcel No.: 0761000170
Address:
Suite No:
Tenant:
doc: Cond - 10/06
14229 55 AV S TUKW
PERKINS RESIDENCE
1: ** *PLUMBING AND GAS PIPING * **
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
8: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
* *continued on next page **
Permit Number:
Status:
Applied Date:
Issue Date:
PG07 -069
ISSUED
03/22/2007
03/22/2007
PG07 -069 Printed: 03 -22 -2007
doc: Cond -10/06
�,rd if
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Print Name: '�V `( 7•�1/ �x
Date:
PG07 -069 Printed: 03 -22 -2007
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
lutp:/lwww.citukwila.wa.us
site Address: 14229 55th Ave S
Tenant Name: New Tenant ❑ Yes ❑ .. No
Property Owners Name: Daniel Perkins
Mailing Address: 14229 55th Ave S
Name: Melissa Croda
Mailing Address: 1345 Guff Road
E -Mail Address: mel tX nwpermit.com
Company Name:
Mailing Address:
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
Contractor Registration Number.
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
Q Applications \Forms- Application.On lined -2006 - Permit Applic tioadoc
Rev;ied: 9-2006
bh
Building Permit No.
Mechanical Permit No. r
Plumbing/Gas Permit No. O - o( -9 1
Public Works Permit No.
Project No.
(For office use only)
King Co Assessor's Tax No.: 0761000170
Suite Number: Floor:
Tukwila
City
WA
State
CONTACT PERSON — who do we contact when your permit is ready to be issued
Company Name:
Mailing Address:
city
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Day Telephone: 360- 945 -2787
Point Roberts
WA
State
City
Fax Number:
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
State
98168
Zip
98281
Zip
Zip
Cit
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Expiration Date:
ARCUJ I-ECT OF RECORD — All plans must be wet stamped by Architect of Record
State
Zip
City
Day Telephone:
Fax Number:
ENGINEER OF RECORD — All plans must be wet damped by Engineer of Record
State
Zip
Page 1 of 6
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath /shower
Drinking fountain or water
cooler (per head)
Wash fountain
(}as piping outlets
Bidet
Food -waste grinder,
commercial
Receptor, indirect
waste
Clothes washer, domestic
Floor drain
Sinks
Dental unit, cuspidor
Shower, single head trap
Urinals
Dishwasher, domestic,
with independent drain
Lavatory
Water Closet
Building sewer or trailer
park se wer
Rain water system — per
drain (inside building)
Water heater and/or
vent
1
Additional medical gas
inlets/outlets — six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water treating
equipment
Repair or alteration
of drainage or vent
piping
Medical gas piping system
serving one to five
inlets /outlets for specific gas
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: WESCO
Mailing Address: 2800 Thomdyke Ave W
Contact Person: Melissa Croda
E Address: melissa@nwpermit.com
Contractor Registration Number: WASHIES971 OB
Building Use (per Intl Building Code):
Occupancy (per Intl Building Code):
Utility Purveyor: Water:
Q:1Applicatiooe\Feeme -App& cations On Line13.2006 - Permit Appliatioadoc
Revisal 9.2005
bi
PLUMBING AND GAS PIPING PERMIT INFORMATION — 206 -431 -3670
Valuation of Plumbing work (contractor's bid price): $ 950.00
Valuation of Gas Piping work (contractor's bid price): $
Scope of Work (please provide detailed information):
Replace 50 gallon gas to gas water heater
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
SEATTLE WA 98199
cit state zip
Day Telephone: 360 - 945 - 2787
Fax Number:
Expiration Date: 09/02/07
Sewer:
Page 5 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Date Application Expires: li (224
Date Application Accepted:
o421-l(A-
Qapplcations\Famis- Application. Oa Lase \3-2006 - Permit Appliutimdoc
Revised: 9-2006
ee
Page 6 of 6
Doc: RECSETS -06
RECEIPT NO: R07 -00407
Initials: JEM
User ID: 1165
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: //wwv.ci.tukwila.wa.us
Payee: WASHINGTON ENERGY SERVICES COMPANY
SET ID: 0322 SET NAME: WASHINGTON ENERGY
SET TRANSACTIONS:
Set Member Amount
M07 -057 281.10
PG07 -069 88.00
PG07 -070 88.00
TOTAL: 457.10
TRANSACTION LIST:
Type Method Description
ACCOUNT ITEM LIST:
Description
MECHANICAL - RES
PLAN CHECK - RES
PLUMING - RES
SET RECEIPT
Payment Date: 03/22/2007
Total Payment: 457.10
Amount
Payment Check 0708 457.10
TOTAL: 457.10
Account Code Current Pmts
000/322.100 230.88
000/345.830 50.22
000/322.100 176.00
TOTAL: 457.10
Output Cspadly It
Nonweelhe ized ICS
V
V
.1
10.4
Maw CFM*
hale •
•
IAkrelax
I .1,1
04.000
08 000
110
. 22 00
105 000 •
600
11¢;000
67
t.,.1
' 120.000
107
I.
00
154
101,500
147.000
101.500
125.000
101- 27 •
15.0
O
i'jrlf � :rio k •i �Jt�:'_�:;:L'iii +��T: It :`�t.:
;.
ItATI>JC '; AND PERFOR."fiANCI
I5JAV Ali a1 v
Input Blue '
NonweeR>olzed ICs 3151 ►voosMlowMorkaatil 46
EWA
FL C1RICA -
eorCkt: sea
(if.SCQf I ROLS
1111EMIll
.,,
•.„
4300
Cadged Temperature Mae Relte
(;77 -T3. i. 1060161
u.
Yr .1 ,_..,.I . +,, 102„ : ,44.
$5. • 47 +00 ' 58000 :.0 •
=:TTi'
r.. 40- - 40• + + 0 INEM5111111
4 440 :.
�. i�S„•�'�c: 7'. -'r:,(� it��+ �+ �E ti.+..'. i�j• � .n:I :��i.,i: "il7 .t,�yT{ririii�A
O.
, •. _ • 930111 It a r . t
2095
sty i 20
cow
1:11E±rn."---111111111111111111111...11111111.11111 111111101M"
4
1$2,000
dill t Me= +•'1. "'"16•5•11 t
-77%.117114 30111011023111110111.11E100111111MIE10111 NMI
IJArA
.
FIIII
li '',7?:" kitr
� O 1a 10 x 6 i�tilr l `
otaerWh- eterxWlde► . '
• Gee Input ratings wecer (U9ad for elevations le 20001 erelevedonsdove20004 .4educetaGnps4p ior each 1O001te See
Refer to Mona! Fuel Go Code Table F4 re Rowe Mrstalkdlon InstrucSins. In Ceaeds. orate M unit 10 Petcentferetwa*m+a 2
4500 $ above see level.,
.. TNae -0atay type b recommended.
lawealtY la accordance ut t U.S. Severnrasnt DOE Mal ptoosautes.
*Airflow
other( SawA -e4i 0� flip tors rasyoccurwhenlrslagetaTec tmene
aefar- A611eris d�sal3►rolum�IrsWPb
kith We, Milt Odeon./
IC64enlvted Contta stlon Systole
NtA-Not Applicable. . . ' •
•
spECuFiCAT14NS
•
P(� --oto1
r
•
PHYSICAL DATA
UNIT $I EERIE
O$00111o8 Waliih1 (Ib)
6ppinq Weight 18)
Cempres ierYype
R819uatRANr
Con
X14)
COND RAN
Air 011001534
AYOty (CFN
Motor till
Motor RIM
co ND COIL
Fa0e A1$$ (eg
Fins part_
Rows
CIrcure
VAG/ECOMPIECE ID)
Vapor
Llquld
REFRIGERANT=UBEV (in. OD)
Vapor (11-80 Mao Length) 3/8 Eta W4 8/4 7/2 718 Ft Tube Imp) 8/6
fbr e i so t vtd t eorao$a amt rata/ d4eremet pet t'tow estntent eons* rr IInn -cis Gu
Note 814 une MUM nadueoon tar props 8 111a5oo,
VAPOR LINE SIZING AND COOLJNG CAPACITY LOSS
PURON 1 —STAGE HEAT PUMP APPLICATIONS
tlrufN0 M
11523 SHUN)
16aoo
1s last
f1P
1-12% • rural
30ooa
1-a Ano
ACCEPT[
Atka
110180 1d111
MOD 03
311
3p
70000
1 - Sage Peon
tr
42808
1-60196 Ryon ors
43083
t -15rg. Ryan are
HP
10080
1-81apr Psan
Standout
AX:CEPOIBLE
WS W
to
Sit
38
304
103
38 et4
7A
We
OS 3A
0/4
tq1
s14
715 0 0
2/4 1 2
tlt8 7A1 0 1
i ts 0 0
80it or less total agvivdenti atn&
16.16
20
1
4
swa
[ONO -UN0 MAMMON: An application le considered
equhaient czo length cda 80 ft
than or when there Is snore an 20 ft verlic separatism between
indoor and outdoor units. These applications require a didanal
000a4r6rirs and firliain modifianioiw for nibble so=
operation. The maximum allowable total equivalent length 15250
il.The maximum =doll operation b; 200 it abut outdoor unit
*454ci
018 024 020 086 042
193 122 238 248 201
232 238 272 280 285
Boma
Futon X1 -4101)
ixv futon Hard
1.13 6.19 0.1 7.69 1.32
P1ope1er Type. Daect 0dre
vend
2595 2395 3255 8265 3260
Sli 1/10 1/3 11S 1/8
800 800 300 800 300
1616 1816 1413
20 20 20
1 2 2
3 6 7
1
8/4 3/4 7/8 713
ata
1126 80E
20 20
Y 2
8 8
•
048
278
913
COOLING CAAAG1YL09S COTOTALGIUMENT L2IE MATH Ft)
810e05ro Apposition tong tine ApptosIon taagrdrae Aocomxles
25 10 00 15+ 100 136 150 175 200 325
1 2 1
0 0 1
O 1 1
0 0 0
1 2 3
0 0 1
0 0 0
1 2 4
0 0 1
0 0 0
4 1 1
O 0 1
O 1 t
1
4
3
0
080
344
11.19 12.5
3873
111
600
5673
t1a
800
3M
20
2
0
W8
1 -1/8
S50
taabove Woof unit,and808whenthaatdo nit isbdow SM
Indoor aait. Pear 1a Accessory Usage Guideline for required
ecaassodes. See Long -Una Application Ouldelhm for required
plping e nab�te tube (Gametes bbond the t� above ford*
to
mialm1 ethecoolingcapadrylost.
gliglawasees
112 ‘4 2%stgsutus
b
I I I
lig 1
1
11 .1.e.:Etigve
g HAM s
i l l �- ti...� 73
l d0� . �.%�� 11! 1
g ;ann 1
14 st , t
tied il
'AA%
5 ginglqtal ;ii;
Vt9:'
1 1
1
I ranian
Trimasa.2
l igaleass
D s
ffS
E
m`'
�NPION �Q��
a
0
8
HUM Peng"
'Jr L 11 SUM '1
WW1
72111021172011111 111. II OLL110LIm�t7�l x
�p 013 12 200 Yl 1711114lf111111 Oa lY�
1114101
t'9%
/ I\
101.7110 1117
l01121 ?3312
11111.
'MME 7AEl win Oi)
l 2tl1 411111
.11411 11 2 .1/4 u It Alt it - 202 i 2411
.1110 1411411441 it 1411 121*
.lti! 124.21 12 1.121 tt 1003 2111
.114I le 1 441 X t 4/1 V 4113 2241
.1111 ors .10 R t . 12 1111 1221
dueal.Wx7.41* 4113 2231
dut K I .MI it all V 4322 Ill
• COMM w » 11111V284
A2
44
At
.02
4.
4.
dr
ti
At
.t1
eta eta 1 .244 11 .1/t 11 .*4441 .tf f
.r/1 • .1111
. *!t t .122 ►r AA .11411 1 .VL J/I • • .1112
.M 1 .141 1E .11E K 40111 422 411$ Au[ 14
o n 1 .Ni LL .143 13 �7 .1It .IIN • on X
Oft 2 .014 11 .144 11 .►14411 .1K AU* ► A11t 14
O X L .041 tt .1/t 22 .211011 .in .01111 aun
412 t .Ali it ■*/t 12 ..!1444 f . f� AUL • .1112 tt
a 42 a ai a s e
. 1t u
V
• 0 0 1
.441 it • 0 0 2 7 *222)43
.27111 • 0 0 A 7 410111*
4n it 3 0 0 2 7 WHIM
411 it 1 0 0 2 • 410113
. ut it 1 e 0 3 • *31113
.141 a; • 0 0 2 7 *10011
7
EMS .1221
S.Nt4LSNaw'Q
10
r-♦ r manna na,w •■•• tar taro -rr v•r rrrr •••••• »y ••• J
GUIDE SPECIFICATIONS 0 CS
GENERAL
System Desedptioa
Outdoor - mounted, ah- cooked, grlhray fern beat pump unit
suitable for ground or rooftop installation. Oak omits of a
hermetic eompreaaor, an air-cooled coil, propeller-type
condenser fan, and a motto! box. Unit will discharge Supply air
upward as shown on coastact drawings. Unit will be and in a
refrigeration circuit to march up to a packaged tbo Dal or toll
,unit.
QvalityAmoaa
ofARt Standard 240.
fisted in the latest ARtdireetnry.
Mal/ ASRRAS and with NEC.
standards and will catty the ULiabel of approval. Unit
will have 0-11L approval.
lbst Method Standard No. 141 (Method 6061) 500-hr
airway tat.
- cooled condemn colilo are pressure tested and ate
outdoor traits are leak tested.
Denim Storage, and Handling
stored and handled per unit tnanufaaumr'a
mcommcadatiaas.
Warranty (for btduaSon by specifying engineer)
PRODUCTS
Equipment
- aacentblcd, dngin - picot. air heat
pomp east Contained whin the cult enclosure b si!
6tutoaywdting, piping, controls, cumprossor, erfrigemot
chaise Ptuoad (R-4I OA), sod special features required
Aorta 11e1d start -up.
Unit l�tbbtnd
bond zed, sod coated with e powder coat paler,
Ems
-drive impeller typa,
dIschatgiog air upward.
a a700al§ aylteer 7316 Komi Ilk tomac w,at 41
MOO MUSA
wire safety gmada.
NWIP 5
AIR- COOiED, SPLIT-SYSTEM HEATPUMP
264A
1-1t2 TO NOMDIAL TONS
-phase
type with dam B Mauled= and pulasnantly lubtk recd
age
— Shafts will be corrosion resistant.
lsolasoaa.
ar d•naarOoit
bonded b craw robes wi c z am Wen eknned,
dehydrated, and sealed.
geftjgwrattnn chnnqoprns
Uqu!d -Ilse shutoff valve with sweat connections,
vapar shutoff valve with sweat DoanCCtiomr,
system charge of Pumas (R -410A) reftigentar, POB
compmasor off, aceurraieta' end reversing valve.
Operating
-- The capacity of the unit will asset or adduced
Btnh at a oaten temperature of It The power
cons mtptbanat full toad will not =cat kW.
wit will have a total aet cooling amadty of
Ruh or meta at oom6tloue of CFM entednt
air tewratu re at the evaporator at •F wet bulb
and _ __. 'F dry bulb, end sir eateries We amt st
grammar DOE conditions.
Electrical Ragtdromente
- Nominal acid electrical cbuactetistica will be v,
sink phase, 60 la. The emit will be capable of
sa1sfaamry operation within voltage limbs of v
to v.
-- Unit elcctrlad power will be tingle point connection.
Special Vauban
•
and descriptions for m features and available
enhancement&
6deronConn WIN
REF
DESCRIPTION
U.S. Installations
Canadian Installations
A
Clearance above grade, veranda, porch, deck, or balcony
1 foot
1 foot
B
Clearance to window or door that may be opened
""1 foot
1 foot
C
Clearance to permanently closed window
'
D
Vertical clearance to ventilated soffit, eaves or overhang
3 feet
3 feet
E
Clearance to unventilated soffit, eaves or overhang
3 feet
3 feet
F
Clearance to outside corner
1 foot
1 foot
G
Clearance to inside corner
2 feet
2 feet
H
Clearance to each side of center line extended above meter /regulator
assembly
*
3 feet within a height 15
feet above the
meter /regulator assembly
I
Clearance to service regulator vent outlet
*
3 feet
Clearance to nonmechanical air supply inlet to building or the
combustion air inlet to any other appliance
""1 foot
1 foot
K
Clearance to a forced air inlet into a building
3 feet
6 feet
L
Clearance above paved sidewalk or paved driveway located on pudic
property
7 feet
M
Clearance under deck, veranda, porch, or balcony (open on 3 sides)
3 feet
3 feet
N
Vent Flue from wall (Flat or Pitched Roof)
2 feet
2 feet
0
Vertical between two terminals on the same wall above each other
5 feet
5 feet
P
Clearance between two vertical flue on the same plane
1 foot
1 foot
Q
Horizontal between two terminals on the same wall
1 foot
1 foot
R
Clearance between two Vertical flue on pitched roof above each other
5 feet
5 feet
S
Clearance from terminal facing a terminal
4 feet
4 feet
INSTALLER'S INSTALLATION INSTRUCTIONS
Locating the vent terminal
d eb t PLEASE CONSULT WITH LOCAL CODES BEFORE INSTALLING THIS UNIT
" For clearances not speafied in ANSI Z223.1 / NFPA 54 or CAN/CGA - B149, please use clearances in accordance with loca
installation codes and the requirement of the gas supplier.
"* 4 feet for units other than Direct -Vent Appliance.
ONLY Rinnai Approved vent materials and components can be used to vent the water
heaters.
When installing your Rinnai vent system, you MUST follow Rinnai's Venting
Instructions found in each vent terminal box. These instructions provide the maximum
allowable vent heights for both horizontal and vertical venting, how to cut the vent
components, and pipe installations.
MN OF UKWILA
MAR 2 2 20071
'ERMrr CENTER
P6D� --t�fi
RECOMMENDED VENT /AIR INTAKE TERMINAL POSITION
Twminl, should be gs positioned as to amid products of
oombwdaf miming openings Into bd* gs a other lugs or
Vents.
® VENT TERMINAL
CV AIR SUPPLY INLET
AREA WHERE TERMINAL IS NOT PERMITTED
any
Maintain 12" of clearance above the highest anticipated snow level or grade, or
whichever is greater. Please refer to your local codes for the snow level in your area.
CO
N
Top of Heater
6
inches
Back of Heater
0
inch
Front of Heater
6
inches
Sides of Heater
2
inches
Floor
12
inches
Vent/Air Intake
0
inches
INSTALLER'S INSTALLATION INSTRUCTIONS
- Warnings- (Commercial Unit)
This manual must be followed exactly.
1) Read the safety issues completely before installing the Rinnai Water Heater.
2) This water heater is suitable for water (potable) heating or space heating.
The piping and components connected to the Rinnai Water Heater must approved
for use in portable water systems.
- Toxic chemicals such as those used for boiler water treatment are NOT to be
introduced to the portable water used for space heating.
The Rinnai Water Heater, if it will be used as a potable water source, must not be
connected to a system that was previously used with a nonpotable
water heating appliance.
- When the system requires water for space heating at temperatures higher
than required for other uses, a means such as mixing valve shall be installed to
temper the water for other uses in order to reduce the scald hazard potential.
3) The Rinnai Water Heater is not suitable for use in pool or spa applications
4) This unit is designed to be installed indoors using the proper vent piping to
exhaust by- products of combustion to the outside environment. Contact your
dealer or Rinnai for proper vent kits. DO NOT operate this unit without vent
piping connected. Exhaust gasses must be expelled outside the home. All pipe
joints shall be taped to help prevent leakage around joints. (Aluminum tape is
recommended.)
5) Maintain proper space around the unit for proper servicing and operation.
Minimum clearances from combustible materials are listed below.
6) Installer must install a Pressure relief
valve. Pipe pressure relief discharge to a
drain or outside environment (see page 41
for pressure relief valve rating).
Rinnai America Z1 FF Models
7) The appliance should be located in an area where leakage of the unit or
connections will not result in damage to the area adjacent to the appliance or
to lower floors of the structure. When such locations cannot be avoided, it is
recommended that a suitable drain pan, adequately drained, be installed under
the appliance.
Top of Heater
6
inches
Back of Heater
0
inch
Front of Heater
6
inches
Sides of Heater
2
inches
Floor
12
inches
Vent/Air Intake
0
inches
INSTALLER'S INSTALLATION INSTRUCTIONS
Wamings- (Residential Unit)
This manual must be followed exactly.
1) Read the safety issues completely before installing the Rinnai Water Heater.
2) This water heater is suitable for residential water (potable) heating ONLY.
DO NOT use this water heater for space heating, combination space heating/
domestic water heating, or commercial water heating applications.
3) The Rinnai Water Heater is not suitable for use in pool or spa applications.
4) This unit is designed to be installed indoors using the proper vent piping to
exhaust by- products of combustion to the outside environment. Contact your
dealer or Rinnai for proper vent kits. DO NOT operate this unit without vent
piping connected. Exhaust gasses must be expelled outside the home. All
pipe joints shall be taped to help prevent leakage around joints. (Aluminum
tape is recommended.)
5) Maintain proper space around the unit for proper servicing and operation.
Minimum clearances from combustible materials are listed below.
6) Installer must install a Pressure relief valve. Pipe pressure relief discharge to a
drain or outside environment (see page 41 for pressure relief valve rating).
7) The appliance should be located in an area where leakage of the unit or
connections will not result in damage to the area adjacent to the appliance or
to lower floors of the structure. When such locations cannot be avoided, it is
recommended that a suitable drain pan, adequately drained, be installed under
the appliance. The pan must not restrict combustion air flow.
Rinnai America 26 FF Models
Contents
of Installer's
Manual
Installer's Instructions
This section is for the Qualified Installer
only. If you are not properly trained,
you should not install this unit. The
warranty may be voided due to installation
by a non-qualified installer. For information
on Rinnai Training Courses, call
1- 800 -621 -9419.
Wamings 26,27
Locating the Vent Terminal 28,29
Performance Data 30
Dimensions 31
Recommended Piping for Installation 32,33,34,35
Venting 36,37
Freeze Protection 38
Gas Piping Sizing Chart 39
Gas Piping Notes 40
Water Piping Notes 41
Pressure Relief Valve 41
Electrical Connection Notes 42
Lighting the Unit 43
Remote Controllers 44,45
Testing 46
Schematic Diagram 47
Rhinai
www.rinnai.us
800 -621 -9419
Rinnai America 25 FF Modems
7) Tum the manual valve located at the gas
inlet of appliance counterclockwis
to "ON ".
8) Tum on all electric power to the appliance.
9) Set thermostat to desired setting.
10) If the appliance will not operate,
Follow the instructions "To Tum Off
Gas To Appliance" and call your
service technician or gas supplier.
To Turn Off Gas To Appliance
1) Set the thermostat to lowest setting.
2) Tum off all electric power to the appliance if service is to be performed.
3) Tum the manual valve at gas inlet of appliance clockwise I to "OFF"
Care of Unit's Exterior:
Keep the exterior cabinet clean. Use a soft cloth and warm water when cleaning the cabinet.
Do Not use volatile substances such as benzene and thinners, as they may ignite, or cause
fading of the paint.
Lime Condition Warning Signal:
If you notice "LC" flashing on the remote key pad, this means the unit is beginning to lime up,
and MUST be flushed. Contact a qualified Rinnai service technician to flush the appliance.
Failure to flush the appliance when "LC" is flashing, will cause damage to the heat exchanger.
Damage caused by lime build up is not covered by the unit's warranty. To reset the LC Fault
Code, turn the power off to the unit. Once power is restored, the LC code will be reset.
Rinnai America 24 FF Models
Warning: If you do not follow these Instructions exactly, a fire or explosion may
result causing property damage, personal injury or Toss of life.
A. This appliance does not have a pilot. It is
equipped with a direct ignition device which
automatically lights the burner. Do Doi try to
Tight the bumer by hand.
B. BEFORE OPERATING: Smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier
than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to Tight any appliance.
• Do not touch any electric switch, do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier'
s instructions.
1) STOP! Read the safety information above
before proceeding.
2) Set the thermostat to lowest setting.
3) Tum off all electric power to the appliance.
4) This appliance does not have a pilot It is
equipped with a direct ignition device which
automatically lights the burner. Do ng try to
light the burner by hand.
5) Tum the manual valve located at gas
inlet of the appliance clockwise f
to "OFF ".
Rinnai America 23
• If you cannot reach your gas supplier, call
the fire department.
C.
Use only your hand to operate remote control
keypad. Never use tools. If the remote
keypad doesn't work, do not try to repair
it, call a qualified service technician. Force
or attempted repair may result in a fire or
explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
has been under water.
OPERATING
INSTRUCTIONS
Closed manual valve
("OFF" position)
Open Manual valve
( "ON" position)
6) Wait (5) minutes to clear out any gas. If
you then smell gas, STOP! Follow "B» in
the safety information above on this label.
If you don't smell gas, go to next step.
FF Models
TROUBLE SHOOTING AND COMMON QUESTIONS
Q - 1 don't have any hot water when 1 open the tap!
A - Make sure there is gas, water and electricity to the Rinnai Water Heater
(the power is turned on and the gas is turned on)
Q - When 1 was using the hot water, the water got cold!
A - If you adjusted the flow from the tap to lessen it, you may have gone below
the minimum flow required. The Rinnai Water Heater requires a minimum
flow rate to operate (see specification page for flow rate of your unit). If
you mix the water with a tap and attempt to get a temperature well below
the temperature being controlled by the unit, it may drop the flow below the
desired minimum flow rate. Decrease the temperature supplied by the Rinnai
Water Heater at the remote control or increase your total flow.
Q - White smoke comes out of the exhaust!
A - During colder weather when the exhaust temperature is hotter than the air,
the exhaust fumes condense producing white steam.
Q - When I open a hot tap. I do not immediately get hot water!
A - Hot water must travel through your plumbing from the Rinnai Water Heater to
the faucet. The time period for hot water to reach your fixture is determined
by the amount of water in your plumbing system between your water heater
and the fixture, water pressure, flow rate of fixture in use, etc.
Q - After 1 tum off the hot water tap, the fan on the Rinnai Water Heaters
continues to run!
A - The fan is designed to be on for 65 seconds after the flow of water stops.
This is to ensure constant water temperatures during rapid starting and
stopping, as well as exhausting any residual gas flue products from the unit.
Rinnai America 22 FF Models
MAINTENANCE & SERVICE INFORMATION
MAINTENANCE SUGGESTIONS
This water heater has been designed and constructed
for a long performance life when installed and operated
properly under normal conditions. Regular inspections,
as outlined in this section, are strongly recommended
as a means of keeping your heater operating efficiently.
1. Cleaning
The water heater must be cleaned annually.
Keep the water heater clear of dust and debris
especially in and around bumer.
Cleaning procedures for the Rinnai Water Heater
are as follows:
1) Turn off and disconnect electrical power. Allow
to cool for one hour.
2) Remove the Front Panel by removing screws.
See parts breakdown on panels.
3) Use pressurized air to remove dust from around
main bumer.
4) Use soft dry cloth to wipe cabinet.
DO NOT DAMAGE OR DISTORT ANY
PARTS OF HEATER.
DO NOT USE WET CLOTH OR SPRAY
CLEANERS ON BURNER.
2. Visual check of main burner flames.
The burner must flame evenly over the entire
surface when operating correctly. The flame must
bum with a clear, blue, stable flame. See the parts
breakdown of the burner for the location of view
ports. Any and all parts removed for inspection or
service must be replaced before operating the unit.
The flame pattern should be as shown in the
following Figures.
SATISFACTORY
VISUAL CHECK
FRONT VIEW
BLUE FUME
UNSATISFACTORY
FRONT VIEW
YELLOW FLAME
* VENT MAINTENANCE
* VENT SYSTEM
Must be checked annually for
blockage or deterioration. See
vent installation instructions.
* MAINTENANCE -
ELECTRIC MOTORS
Motors are permanently
lubricated and need no
lubrication. Keep fan and motor
free of dust and dirt, clean
annually.
Rinnal America 21 FF Models
MAINTENANCE & SERVICE INFORMATION
Warning: Always turn off the electrical power supply, the manual gas valve
and the manual water control valve whenever servicing the unit.
1
Rinnal America
The Rinnai Water Heater should be checked by a Properly Trained
Technician once a year. A Properly Trained Rinnai Technician
should perform any repairs that may be necessary.
The following items should be checked each inspection:
1) The area around the Rinnai unit should be free from combustible materials
such as cloth, vegetation and building materials. (see page 8)
2) Check burners for presence of foreign debris, insects or bugs. These items
are not covered by the unit's warranty.
3) Remove and dean the inlet water filter.
4) Keep the appliance area dear and free from combustible materials, gasoline,
and other flammable vapors and liquids.
5) Do not obstruct flow of combustion and ventilation air.
In the case of any fault or error message from the Rinnal Water Heater,
first turn all hot water taps off. Wait for 5 seconds. Turn the hot water tap back
on. If the error message still remains, call your Rinnai Authorized Service
Representative or Rinnai at 800 - 621 -9419.
Should overheating occur or the gas supply fail to shutoff, turn off the manual
gas control valve to the appliance.
DO NOT ATTEMPT TO SERVICE YOUR Rinnai YOURSELF
Call a Rinnai Authorized Service Technician or call your installer.
20 FF Models
ERROR MESSAGES
The Rinnai Water Heater has the ability to check its own operation continuously. If a fault
occurs, an Error Message will flash on the Digital Monitor of the Remote Controllers. This
assists with diagnosing the fault, and may enable you to overcome a problem without a service
call. Please quote the code displayed when inquiring about service.
NOTE: Failure to remedy faults may result in severe bums, scalds, and/or death.
Code
Displayed
Fault
Remedy
03
10
11
12
14
16
32
33
34
52
61
65
71
72
LC
(00)
Power interruption during Bath fill
(Water will not flow on power reinstatement).
Air Supply or Exhaust Blockage Check that nothing is blocking
the air intake or exhaust.
No Ignition
Flame Failure
Earthing Failure
Turn off all hot water taps.
Press ON /OFF twice.
Check that the gas is turned
on at the water heater, gas
meter or cylinder.
Check that the gas is turned
on at the water heater and gas
meter. Check for obstructions
in flue outlet.
Thermal Fuse Service CaII
Over Temperature Warning Service Call
Outgoing Water Temperature Sensor Service Call
Faulty
Heat Exchanger Outgoing Water Service Call
Temperature Sensor Faulty
Combustion Air Temperature Service Call
Sensor Faulty
Mod. Solenoid Valve Answer Abnormal Service Call
Combustion Fan Failure Service Call
Water Flow Control Faulty Service Call
(Does not stop flow properly).
Solenoid Valve Driving Circuit Faulty Service Call
Flame Sensing Device Faulty Service Call
Scale build -up in Heat Exchanger Service Call
(When checking maintenance code history,
"00" is substituted for "LC ")
Rinnai America
19
FF Models
model
temperature
REU- V2532FFU
REU- V252OFFU
98
100
102
104
106
108
110
115
120
125
130
135
140
—
—
—
REU- V252OFFUC
—
—
—
—
—
—
—
—
120
125
130
135
140
150
160
185
REU- V2532FFUC
98
100
102
104
106
108
110
115
120
125
130
135
140
150
160
185
Approx.
temperature ( °C)
37
38
39
40
41
42
43
46
49
52
54
57
60
66
71
85
CONTROLLERS SET PATTERN /TEMPERATURE TABLES
Temperature controllers allows precise temperature control by the user. When used correctly,
the hot water unit will deliver the selected temperature, even when the water flow is vaned,
or more than one tap is in use. Each Temperature Controller can be individually programmed,
however the water heater unit can only deliver one set temperature at any time. The available
temperatures ( ° F) are as follows:
Temperature Table by Models
Suggested temperatures are:
Kitchen 120 ° F - 130 ° F, Shower 98 ° F - 110 ° F, Bath fill 102 ° F - 114
These temperatures are suggestions only. You may find higher or lower temperatures more comfort-
able. Maintaining lower temperatures helps save energy. To obtain water temperatures lower than
98 ° F, simply add cold water.
Deluxe Controllers are an optional extra. 'Controller' and 'Deluxe' Controllers can be installed togeth-
er. Controllers allow temperature selection only. 'Deluxe' Controllers have temperature selection, bath
fill and dock functions.
Controllers allow the water temperature to be set from the various locations where they are
installed. The temperature selected will be available to all outlets. Below are the combination of
Controllers that are offered by Rinnai:
Controllers Combination Pattern
Water Smart / Bath Fill Temperature Table
Rinnai America
10
Water Smart / Bath
Fill temperature cannot
exceed 120 ° F for the
following commercial
models with no by -pass:
REU- V252OFFUC.
FF Models
temperature
water smart/
bath fill temperature
98
100
102
104
106
108
110
112
114
116
118
120
Approx.
temperature ( °C)
37
38
39
40
41
42
43
44
46
47
48
49
CONTROLLERS SET PATTERN /TEMPERATURE TABLES
Temperature controllers allows precise temperature control by the user. When used correctly,
the hot water unit will deliver the selected temperature, even when the water flow is vaned,
or more than one tap is in use. Each Temperature Controller can be individually programmed,
however the water heater unit can only deliver one set temperature at any time. The available
temperatures ( ° F) are as follows:
Temperature Table by Models
Suggested temperatures are:
Kitchen 120 ° F - 130 ° F, Shower 98 ° F - 110 ° F, Bath fill 102 ° F - 114
These temperatures are suggestions only. You may find higher or lower temperatures more comfort-
able. Maintaining lower temperatures helps save energy. To obtain water temperatures lower than
98 ° F, simply add cold water.
Deluxe Controllers are an optional extra. 'Controller' and 'Deluxe' Controllers can be installed togeth-
er. Controllers allow temperature selection only. 'Deluxe' Controllers have temperature selection, bath
fill and dock functions.
Controllers allow the water temperature to be set from the various locations where they are
installed. The temperature selected will be available to all outlets. Below are the combination of
Controllers that are offered by Rinnai:
Controllers Combination Pattern
Water Smart / Bath Fill Temperature Table
Rinnai America
10
Water Smart / Bath
Fill temperature cannot
exceed 120 ° F for the
following commercial
models with no by -pass:
REU- V252OFFUC.
FF Models
Remote and Deluxe Controllers
1
MC- 91 -1US
+
—
+
—
+
—
2
MC- 91 -1US
+
MC- 91 -1US
+
—
+
—
3
MC- 91 -1US
+
MC- 91 -1US
+
MC- 91 -1US
+
—
4
MC- 91 -1US
+
MC- 91 -1US
+
MC- 91 -1US
+
**MC- 91 -1US
5
MC -91 -1 U S
+
BC -100V
+
MC -100V
+
—
6
MC -91 -1 US
+
MC -91 -1 US
+
BC -100V
+
MC -100V
'*SAa r_nntrn!/ar manual In controller carton box for more Infomation detail.
CONTROLLERS SET PATTERN /TEMPERATURE TABLES
Temperature controllers allows precise temperature control by the user. When used correctly,
the hot water unit will deliver the selected temperature, even when the water flow is vaned,
or more than one tap is in use. Each Temperature Controller can be individually programmed,
however the water heater unit can only deliver one set temperature at any time. The available
temperatures ( ° F) are as follows:
Temperature Table by Models
Suggested temperatures are:
Kitchen 120 ° F - 130 ° F, Shower 98 ° F - 110 ° F, Bath fill 102 ° F - 114
These temperatures are suggestions only. You may find higher or lower temperatures more comfort-
able. Maintaining lower temperatures helps save energy. To obtain water temperatures lower than
98 ° F, simply add cold water.
Deluxe Controllers are an optional extra. 'Controller' and 'Deluxe' Controllers can be installed togeth-
er. Controllers allow temperature selection only. 'Deluxe' Controllers have temperature selection, bath
fill and dock functions.
Controllers allow the water temperature to be set from the various locations where they are
installed. The temperature selected will be available to all outlets. Below are the combination of
Controllers that are offered by Rinnai:
Controllers Combination Pattern
Water Smart / Bath Fill Temperature Table
Rinnai America
10
Water Smart / Bath
Fill temperature cannot
exceed 120 ° F for the
following commercial
models with no by -pass:
REU- V252OFFUC.
FF Models
Using Water Smart/ Bath Fill
Press 'Water Smart / Bath Fill' button once. The 'Water Smart / Bath
Fill' button will illuminate and a tone will sound. The 'Bath' indicator
will also be displayed in the kitchen Controller monitor (Deluxe Models
ONLY).
The voice prompt will say "The hot water system is ready. Open the
hot water tap ".
Open the hot water tap for the relevant shower or bath.
The 'In Use' indicator Q will illuminate at all Deluxe Temperature
Controller(s) and the shower will run or the bath will start to fill.
To Stop Water Smart / Bath Fill Operation
If you wish to stop the water flow whilst the 'Water Smart / Bath Fill'
button is in operation, simply press the 'Water Smart / bath Fill'
button. The 'Water Smart / Bath Fill' button will flash and the
voice prompt will say "Hot water is not available. Tum off all hot
water taps, and push the Bath Fill button ". Follow the voice prompt
instructions.
When Water Smart / Bath Fill Operations Finishes
Once the Water Smart / Bath fill operation finishes, the following
events will occur:
1 The flow from the shower / bath hot water tap will cease.
2. The 'Water Smart / Bath Fill' button will flash.
3. The Kitchen Controller 'Bath' indicator will flash (Deluxe Models)
4. A tone will sound.
5. The voice prompt will say "Bath fill is complete. Tum off the
bath hot water tap, and push the Bath fill button."
Follow the voice prompts instructions. Note that the
hot water unit will not allow hot water to flow from any
fixture until the 'Water Smart / Bath Fill' button has
been changed.
6. The 'Water Smart / Bath Fill' button light on
the Bathroom Controller and the 'Bath' indicator
on the Kitchen Controller monitor will go out.
COMBINING CONTROLLERS AND DELUXE CONTROLLERS
Controller and Deluxe Controller can be combined and will function as
described in other sections of this manual. Refer to the table on page 18
Rinnal America 11
l Ll O sath
r
PM t•IUU
HOT
HOT
FF Models
DELUXE BATHROOM CONTROLLER
IT IS THE CUSTOMERS RESPONSIBILITY TO MONITOR THE BATH FILL
REMOTE CONTROLLER FUNCTIONS.
OPERATING THE WATER SMART / BATH FILL BUTTON
The `Water Smart / Bath Fill' button allows a preset water volume and
temperature to be selected and run automatically.
Initial Settings
When you press the `Water Smart / Bath Fill' button, a Shower /
Bath Volume will appear on the indicator. When a deluxe bathroom
controller(s) is first turned on, the default shower / bath fill volume
is set to 25 gallons. The shower / bath volume can be lowered to a
minimum of 10 gallons or raised to a maximum of 120 gallons.
Programming shower / Bath Volume and Temperature
With the system on, select a Deluxe Bathroom controller(s) and ensure that it currently has
priority, If it does not have priority, press the `Priority' button once and the `Priority' button will
To select the desired delivery temperature, use the
`Temp.' ❑ or 0 buttons.
The selected temperature will be displayed on the
bathroom controller monitor and will remain as the
default temperature until it is changed.
To select the volume of water to be used 12y_ the
shower / bath, use the `Water Vol.' ❑ or U
buttons.
The selected volume is displayed at the Right of
the controller monitor numerically.
When filling a bath for the first time, it is
recommended that a low bath fill volume such as
25 gallons or lower (if available) be used. During
any subsequent bath fills, the volume can then be
adjusted to suit your known bath volume and / or
desired fill level.
Rinnai America
16
a
0
n
Be careful not to overfill the bath, an average bath volume is 60 gallons. It is
recommended that when filling a bath for the first time you should:
Remain by the bath during the filling process.
• Use a low bath fill volume such as 25 gallons or less.
'Water Smart / Bath Fill' button is unavailable with the MSA Controller System.
FF Models
DELUXE BATHROOM CONTROLLER
Setting the Sound Volume
The voice prompt sound volume for all Deluxe
Controller(s) can be set individually. To do
this, press the 'Sound Vol.' button. The default
voice prompt sound volume is medium, each
subsequent press of the 'Sound Vol.' will cycle
through the available volume settings in the
following order. High Voice - Off Voice (beep)
- Off Sound (no beep) - Low Voice - Medium
Voice.
Press the 'Sound Vol.' again to complete setting
of the sound volume and return to normal
operation.
Adjusting Temperature
Rinnai America
Simply press the 'Hot water temp.' ❑ or
buttons until the required temperature is
displayed on the Digital Monitor.
To Operate the hot water unit, open any hot
water tap. This will automatically light the
burner providing hot water. The red flame of the
water heater 'In Use Indicator' 4 will illuminate
on the Temperature Controller.
Once the hot water is running, if the set
temperature is either too hot or cold, press the
'hot water temp. ❑ or ❑ buttons until the
desired temperature is reached.
15
TEMPERATURE CANNOT BE AD-
JUSTED EXCEPT BETWEEN 98
°F AND 110°F WHEN ANY HOT
WATER TAP IS OPEN.
CHECK WATER TEMPERATURE BEFORE USE.
A parent should always check the temperature before a child is placed in contact
with hot water.
Each time a button is pressed, a 'beep' will sound. The 'beep' sound and the `bath fill
complete' buzzer can be muted by pressing the Temperature Controller Up and Down
buttons simultaneously for more than 3 seconds. To return to original settings, repeat this
step.
Avoid getting water in the speaker as this may cause damage.
FF Models
Setting The Sound Volume
To do this, press the 'Function' Button, the default voice prompt sound volume is medium, each
subsequent press of the F and ❑ Button will cycle through the available volume settings in
the following order: High Voice - Off Voice (beep) - Off Sound (no beep) - Low Voice - Medium
Voice.
Setting The Clock (MC -100V Deluxe Controller ONLY)
The clock is a 12 hour AM /PM style display. To set the time, press the 'Function' Button twice
within 10 seconds. Press the Q and ❑ Buttons to adjust the time. When you get close to
the time you wish to set, press the button intermittently to avoid going further than the desired
time.
Press the 'Function' Button again to complete setting the clock and return to normal operation.
Adjusting Temperature
Simply press the ❑ or ❑ buttons until the required temperature is displayed on the Digital
Monitor.
To Operate the hot water unit, open any hot water tap. This will automatically Tight the burner
providing hot water. The red flame of the water heater 'In Use Indicator' 4 will illuminate on
the Controller.
Once the hot water is running, if the set temperature is either too hot or cold, press the ❑ or
Q buttons until the desired temperature is reached.
Rinnai America
HOT
TEMPERATURE CANNOT BE
ADJUSTED EXCEPT BETWEEN
88 ° F AND IIQ ° FWHENANY
HOT WATER TAP IS OPEN.
14
FF Models
DELUXE CONTROLLER
•
Digital Monitor
Indicates the selected water
temperature. Error messages flash
in the event of a failure.
•
in Use Indicator
Indicates that a hot water tap is open
and that control of the temperature is
taken at another controller.
•
ABOUT THE DELUXE CONTROLLER (MC -100V 1US)
Water Temperature Indicator
Indicates the selected hot water
temperature.
Clock
12 Hour AM / PM clock. In the event
of a fault, codes for error messages
will flash here. •
Call
Allows user to contact another
controller. Can be used as a
communication channel for errands
or in emergency situations.
With power interruption, water heater will automatically default to the ON position to
provide hot water.
DELUXE BATHROOM CONTROLLER
ABOUT THE THE DELUXE BATHROOM CONTROLLER (BC- 100V -1US)
In Use Indicator
Indicates that a hot water tap is open and that control
of the temperature is taken at another controller.
Priority
Pressing takes control of the water
temperature by this controller only
when all taps are off.
•
Call
Allows user to contact another
controller. Can be used as a
communication channel for errands
or in emergency situations.
•
Clock •
12 Hour AM / PM clock. In the event
of a fault, codes for error messages
• will flash here.
Thermostat
Increases or decreases the desired
water temperature.
Rinnai America
Function
Enables the user to set the dock
and sound volume functions.
i
hill
•
13
Water Smart / Bath Fill Indicator
Used to select Water Smart / Bath All Function.
Sound Volume
Used to select the voice prompt
volume.
l
On/Off
Beth Mil
R-L4
Thermostat
Increases or decreases the desired
water temperature.
Priority
Pressing takes control of the water
temperature by this controller only
when all taps are open.
ON/OFF
Used to switch the water heater on
and off.
ON/OFF
Used to switch the water heater on
and off.
Water Smart /Bath Fill
Used to select Water Smart /Bath
FN Function.
Power Save
Indicates that the remote is in the
energy saving mode.
Water Volume
Used to select Water Smart / Bath
Fill volumes.
FF Models
REMOTE CONTROLLER OPERATION
C Digital Monitor
Indicates the selected water
temperature. Error messages
Rash in the event of a failure.
Thermostat
I ncreases or decreases
the desired water
temperature.
In Use Indicator
I n d icates that a hot water tap
is open and that control of the
temperature has been taken at
another controller.
120
Approu Water Tamp
0
Hot water temp.
•nu
In Use
oNoff
DIAGNOSTIC USE OF CONTROLLER
1. To Display Maintenance Codes: Press 'On/Of' button. To sequence through stored
maintenance codes, press 'On/Off' followed by the
2. To Display Water Flow through water heater: Press Ell thermostat button, hold
for 2 seconds and simultaneously press 'On/Off' button.
3. To display Outlet Water Temperature: Press ❑ 'thermostat button', hold for 2
seconds and simultaneously press 'On/Off' button.
Priority Indicator
Indicates whether this
controller has priority
control over the water
temperature
Priority
Pressing takes control
of the water temperature
by this controller only
when all taps are off.
thermostat button.
TO CHANGE TEMPERATURES FROM ° F to ° C
1. Press and hold `On/Off' button for 5 seconds while water heater is OFF.
2. To change back from ° C to ° F, please repeat step 1.
MUTE
To eliminate the beeping sound, press and hold Q and ❑ button
simultaneously until a 'beep' is heard (approximately 5 seconds).
ON /OFF
Used to switch the
water heater on and off
Rinnai America 12 FF Models
1
GENERAL CONTROLLER INFORMATION
MC- 91 -1US (comes with the unit)
REMOTE CONTROLLERS IDENTIFICATION
BC-1 00V 1 US (optional)
MC -100V 1 US (optional)
f
Pr huffy
■
Call
gal.
ir
1 3 j
kJLIJ()TA]
-
On/Off
PowerSave
The controller(s) for the Rinnai Water Heater allow the customer to control the functions of the
water heater and to diagnose certain fault conditions
Rinnai America 11 FF Models
ABOUT HOT WATER
Hot Water Is Dangerous, especially for the young and the elderly or
the infirm. The Rinnai Water Heater allows you to precisely control the
temperature of your hot water, ensuring safe hot water temperatures.
Water Temperatures over 125 °F can cause
severe bums instantly or death from scalds.
Hot Water can cause first degree bums with
exposure for as little as:
3 seconds at 140 °F
20 seconds at 130 °F
8 minutes at 120 °F
Test the temperature of the water with your
elbow before placing a child in the bath or
shower.
Do not leave a child or an infirm person in
the bath unsupervised.
Scalds - First Aid
1) Remove clothing; Remove all wet clothing, quickly. Wet clothing retains the heat.
2) Apply cold water for 30 minutes; Immediately submerge the burnt area in cold
water for 30 minutes to reduce the heat in the skin, preventing deeper buming.
Never use butter, oils or ointment to cover the bum. They may retain the heat.
3) Keep the scalded person warm; Place a blanket around the person.
4) Seek Medical Advice; CaII your medical advice hotline and describe the scald,
follow their directions.
Rinnai America 10 FF Models
Ell Adjusting Temperature
The outlet water temperature of the Rinnai
Water Heater can only be adjusted by
the user using the remote controller(s).
To adjust the setpoint temperature of
the Rinnai Water Heater, all hot water
taps must be closed, and all circulating
pumps turned off (where applicable). The
temperature displayed on this remote
controller will also be displayed on all
other remote controller(s).
Rinnai America
TEMPERATURE CANNOT BE ADJUST-
ED EXCEPT BETWEEN 98 ° F AND
110 ° F WHEN ANY HOT WATER
TAP IS OPEN.
[2] To take control of the Rinnai Water Heater
all hot water taps must be closed. Press
the "Priority button" on the Controller you
want to set the temperature with, and
the green "Priority" indicator Tight will
0
glow. This indicates that the Rinnai Water
Heater is ready to supply hot water at
the set temperature as soon as a tap is
opened.
Note: Rinnai Water Heater will not provide
hot water instantly at the hot water
fixtures. Any cold water existing in the hot
water lines must be purged first.
CHECK WATER TEMPERA-
TURE BEFORE ENTERING
SHOWER OR BATH.
J
4
Simply press the 0 or Q button
until the required temperature is
displayed on the Digital Monitor.
There is a hot water scald potential if
the thermostat is set to high.
[.7
Hot water temp.
[O]
pa r-
NOTE
•
CHECK LOCAL CODES
FOR THE MAXIMUM
WATER TEMPERATURE
SETTING ALLOWED
WHEN USED IN
NURSING HOMES,
SCHOOL, DAY CARE
CENTERS, AND ALL
OTHER PUBLIC
APPLICATIONS.
HOT
To operate the Rinnai Water Heater
simply turn any hot water tap on.
This will automatically light the burner
providing hot water at the preset
temperature. If the optional remote
controller(s) have been installed, the
red "IN USE" indicator will glow on
all remote controller(s).
9 FF Models
Always check water temperature by hand
before entering the shower or bath. The
temperature may have been changed.
The Rinnai Water Heater controls the water
temperature automatically. To do this, it
sometimes needs to change the water flow
accordingly. The water flow from the hot water
tap may vary after the selected temperature at
the remote controller(s) is altered. The water
flow may also vary from summer to winter, as
incoming water temperatures differ.
HOT
Summer 60 °F
Incoming water
Rinnal America
1
■
The water temperature can only be adjusted
between 98 °F and 110 °F when the hot water
tap is open, and hot water is flowing.
Winter 40 °F
Incoming water
HOT
8
Depending on the weather conditions and
the length of the pipe between the Rinnai
Water Heater and the tap in use, there may
be a variation between the temperatures
displayed at the remote controller(s) and the
temperature of the water at the tap.
HOT
Do not clean remote controller(s) with
solvents. Use a soft damp cloth.
The vent/air intake should be positioned away
from flammable materials, trees, shrubs, etc.
Do not connect vent to natural draft vents
or fireplaces, this unit can only be used
with an approved Rinnai /Ubbink vent kit and
components. Do not vent unit into other
rooms. Vent terminal must be outside.
FF Models
FEATURES OF YOUR NEW WATER HEATER
The Rinnai Water Heater is one of the most advanced water heaters available.
It supplies hot water continuously at the temperature preset in the unit or at the
temperature set on the optional remote controller(s). Installation of remote controller(s)
are recommended for optimum performance.
The Rinnai Water Heater never runs out of hot water. While electricity, water and gas
supplies are connected, the Rinnai Water Heater produces hot water whenever the hot
tap is open.
The gas burner lights automatically when the hot water tap is opened, and goes out
when the tap is closed. Ignition is electronic, there is no pilot light. When the hot water
tap is off, no gas is used. You save energy and money with the Rinnai Water Heater.
The temperature of the outgoing hot water is constantly monitored by a built in sensor. If
the temperature of the outgoing water rises to more than 6 degrees above the selected
temperature (shown on the digital remote control) the gas burner will automatically go
out. The gas burner will re- ignite once the outgoing hot water temperature falls below the
selected temperature.
Built into the microprocessor of the Rinnai Water Heater is the ability to LIMIT THE
MAXIMUM TEMPERATURE of the hot water supplied by the Rinnai Water Heaters.
Without the connection of a remote controller(s), the Rinnai Water Heater is preset to
deliver water at 104 ° F (Residential) and 140 ° F (Commercial).
a Residential Unit: With the remote controller(s) the water temperature is adjustable from
98 to 140 ° F. The water temperature cannot be set to a temperature other than
120 ° F without the use of a remote controller unit.
c" Commercial Unit: With the remote controller the water temperature is adjustable up to
185 ° F. The water temperature cannot be set to a temperature other than 140 ° F
without the use of a remote controller unit.
Q Error messages are displayed on the optional remote controller(s), simplifying service
calls.
The Rinnai Water Heater incorporates a device to minimize temperature fluctuations (cold
water sandwich effect) when the water is off, then on again. This effect can be eliminated
by installing the Rinnai Water Heaters with a circulation loop with a small storage tank.
The sound (noise) level from the Rinnai Water Heaters is very low.
The Rinnai Water Heater is a very compact direct vented device. It saves valuable floor
and wall space.
Rinnai America T FF Models
Rinnai
Operation / Installation Manual
To Suit Models:
REU- V252OFFU R53
REU- V252OFFUC C53
REU- V2532FFU R85
REU- V2532FFUC C85
(Residential and Commercial indoor unit)
ANS Z21.10.3•CSA 4.3
WARNING: If the information In these instructions is not followed exactly, a fire
or explosion may result causing property damage, personal injury or death.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency
or the gas supplier.
MY Off
KR 22 2001
PEn7, "T C[:a
PRA--obi
Model
V2532FFU
1 V2532FFUC
I V252OFFU
1 V252OFFUC
Minimum Gas Consumption Btu/h
15,000
Maximum Gas Consumption Btu/h
180,000
Hot water capacity, (50°F rise)
0.6 to 6.5 GPM
0.6 to 5.3 GPM
Hot water capacity, (35 °F rise)
0.6 to 8.5 GPM
0.6 to 5.3 GPM
Factory TemperatureSetting
104 °F
140°F
104 °F
140 °F
Maximum Temperature Setting
140 °F
185 °F
140 °F
185 °F
Minumum Temperature Setting
98 °F
120°F
Weight
49 lbs.
Efficiency Rating
87%
Noise level
49 dB (A)
Electrical
Consumption
Normal
75 watts
Standby
5.5 watts
Anti-frost Protection
100 watts
By -Pass Control
Electronic
Fixed
' None
Minimum
Gas Supply
Pressure
Natural Gas
r W.C.
Propane
10° W.C.
Maximum
Gas Supply
Pressure
Natural Gas
10.5" W.C.
Propane
13.5" W.C.
Type of Appliance
Temperature controlled continuous now gas hot water system.
Operation
With or without remote controls, mounted in kitchen, bathroom, ect.
Exhaust System
Direct Vent - Forced Combustion
Approved Gas Type
Natural Gas or Propane - Ensure unit matches gas type Ws being installed on.
Connections
Gas Supply: 3/4' MNPT, Cold Water Inlet: 3/4' MNPT, Hot Water Outlet: 314' MNPT
Ignition System
Direct Electronic Ignition
Electric Connections
Appliance: AC 120 Volts, 6OHz. Remote Control: DC 12 Volts (Digital)
Water Temperature Control
Simulation Feedforward and Feedback.
Water Supply Pressure
Minimum Water Pressure: 20 PSI (Reoonvnended 30-80 PSI for maximum performance)
Maximum Water Supply Pressure
150 PSI
Remote Control Cable
Non-Polartzed Two Core Cable
afety DeVICeS
Flame Failure - Flame Rod
Boiling Protection - 210 °F
Remaining Flame (OHS) 207 °F Bi -Metal Switch
Thermal Fuse 264 °F
Automatic Frost Protection - Bi -Metal Sensor & Anti-Frost Heaters
Combustion Fan RPM Check - Integrated Circuit
Over Current - Glass Fuse (3 amp)
If remote tails or becores disconnected one defaults to 100°F with water lowing, this is an anti-scald feature.
Rinnai is continually updating and improving products, therefore, specifications are .
subject to change without prior notice. Local, state, provincial and federal codes must be
adhered to prior to installation.
Rinnai America
2
FF Models
Item
Period of Coverage
Commercial
-
Residential
Heat Exchanger
5 Years
10 Years*
All other Parts and
Components
5 Years
5 Years*
Reasonable Labor
1 Year
LIMITED WARRANTY
Rinnai Water Heater
Warranty031705COMM - -V2
WHAT IS COVERED?
This Warranty covers any defects in materials or workmanship when the product is installed and
operated according to Rinnai written installation instructions, subject to the terms within this limited
warranty document. This Warranty applies only to products that are installed by a state qualified
or licensed contractor. Improper installation may void this Warranty. Rinnai strongly suggests
that you use an installer who has attended a Rinnai product knowledge lass before installing
this water heater. This Warranty extends to the original purchaser and subsequent owners, but
only while the product remains at the site of the original installation. This Warranty only extends
through the first installation of the product and terminates if the product is moved or reinstalled at
a new location.
HOW LONG DOES COVERAGE LAST?
*Important
Period of coverage is 3 years from date of purchase when used as a circulating water heater
within a hot water circulation loop, when the water heater is in series with a circulation system
and all circulating water flows through the water heater.
WHAT WILL RINNAI DO?
Rinnai will repair or replace the product or any part or component that is defective in materials
or workmanship, except as set forth below: Rinnai will pay reasonable labor and shipping costs
to repair the product. AU repairs must be performed using genuine Rinnai parts. All repairs or
replacements must be performed by an individual or servicing company that is properly trained,
state qualified or licensed to do this type of repair.
Replacement of the product or replacement of the heat exchanger may be authorized by Rinnai
only. Rinnai does not authorize any person or company to assume for it any obligation or liability
in connection with the replacement of a product or heat exchanger. If Rinnai determines that
repair of a product is not possible, Rinnai will replace the product with a comparable product, at
Rinnai's discretion. If a component or product returned to Rinnai is found to be free of defects in
material or workmanship, or damaged by improper installation or damaged during return shipping,
the warranty claim for product, parts and labor may be denied.
Rinnal America 3 FF Models
Description
pH
TDS (Total
DissoivedSads)
Total
Hardness
Aluminum
Chlorides
Copper
Iron
Manganese
Zinc
Maximum
Levels
6.5 to 8.5
Up to 500
mg/L
Up to
11.7 gpg
Up to
0.2 mg/L
Up to
250 mg/L
Up to
1.0 mg/L
Up to
0.3 mg/L
Up to
0.05 mg/L
Up to
5 mg/L
LIMITED WARRANTY
Rinnai Water Heater
Warranty031705COMM -V2
HOW DO I GET SERVICE?
Simply contact a qualified Service Dealer or Installer for the repair of products under this Warranty.
Failure to use a qualified Service Dealer or Installer to provide repair service may void the
Warranty. For the name of the qualified Service Dealer or Installer nearest you, please contact
the company that installed the water heater, or
• Your local HVAC /plumbing dealer, gas service technician or place of purchase
• Visit the Rinnai website www.rinnai.us
• Call Rinnai at 1- 800 -621 -9419 or write to Rinnai, 103 International Drive, Peachtree City, Georgia
30269
Proof of purchase is required to obtain warranty service. You can show proof of purchase with a
dated sales receipt, by completing and mailing the enclosed Warranty registration card within 30
days of purchasing the product or by registering online at www.rinnai.us . Please complete the
Warranty registration either online or mail it to Rinnal at the address shown on the card.
Receipt of warranty registration by Rinnai will constitute proof -of- purchase for this product.
However, Warranty registration is not necessary in order to validate this Warranty.
WHAT IS NOT COVERED?
This Warranty does not cover any failures or operating difficulties due to accident, abuse, misuse,
alteration, misapplication, acts of God, improper installation, improper maintenance or service,
inadequate water quality, scale buildup, freeze damage or for any other causes other than defects
in materials or workmanship. This warranty does not apply to any product whose serial number or
manufacture date has been defaced. This Warranty does not cover any product when used as a
pool or spa heater.
This Warranty does not apply if the water supply to the water heater does not meet the National Secondary
Drinking Water Regulations, as set forth in the U.S. Code of Federal Regulations, 40 CFR, Chapter 1, Part
143 or the water supply exceeds chemistry or impurity limits as shown in the chart below.
Rinnai is not liable for any special, incidental, indirect or consequential damages that may arise,
including damage to person or property, loss of use, failure to install drain pan under unit, or
inconvenience. Some states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation may not apply to you.
LIMITATION ON IMPLIED WARRANTIES
Any implied warranties of merchantability and fitness arising under state law are limited in duration
to the period of coverage provided by this limited Warranty, unless the period provided by state law
is Tess. Some states do not allow limitations on how long an implied Warranty lasts, so the above
limitation may not apply to you.
This Warranty gives you specific legal rights, and you may also have other rights which vary from
state to state.
Rinnal America 4 FF Models
Specifications 2
Limited Warranty 3,4
Owner's Installation Information 6
Features of Your New Water Heater 7
Safety Issues 8
Basic Operation 9
About Hot Water 10
Scalds -First Aid 10
General Controller Information 11
Remote Controller Operation 12
Deluxe Controller 13,14,15,16,17
Controllers Set Pattern/Temperature Tables 18
Error Messages 19
Maintenance & Service Information 20,21
Trouble Shooting and Common Questions 22
For Your Safety Read Before Operating 23
Operating Instructions 23,24
Care & Lime Condition Warning 24
Installer's Instructions 25 -47
Rinnai America 5 FF Models
OWNER'S INSTALLATION INFORMATION
All Rinnai water heater(s) MUST be installed by a state qualified or licensed
contractor. Failure to comply with state and local codes pertaining to water
heater installations may void the warranty on your new water heater(s). It is
the responsibility of the person having the water heater installed to ensure
the installing contractor has proper licences and permits for installing
water heater(s) in your location. In addition to licensing and permits, Rinnai
encourages all installing contractors to attend a product knowledge class
before installing any of our water heaters to help insure maximum customer
satisfaction and maximum warranty coverage. Failure to comply with state
and local codes may result in non - compliance and may void the warranty of
the water heater(s).
This appliance must be installed in accordance with local codes, or in the ab-
sence of local codes, the National Fuel Gas Code, ANSI Z223.1 /NFPA 54 andlor
the CSA B149.1, Natural Gas and Propane Installation Code.
Install this product indoors ONLY, p0 NOT install outdoors.
Do Not use this appliance if any part has been underwater. Immediately call
a qualified service technician to inspect the appliance and to replace any
part of the control system and any gas control which has been underwater.
Detailed instructions on the proper installation practices to follow for the
installation of your new hot water heater(s) are included at the back of this
manual.
Rinnai America 6 FF Models
07 -31 -2007
MELISSA CRODA
1345 GULF RD
POINT ROBERTS WA 98281
RE: Permit No. PG07 -069
14229 55 AV S TUKW
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the Uniform Plumbing Code and/or International Fuel Gas Code, every permit issued by the Building Division under the
provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Plumbing and/or Gas Code does allow the Building Official to approve one extension of time for an
additional period not exceeding 180 days. Extension requests must be in writinz and provide satisfactory reasons why circumstances
beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 09/18/2007 , your permit will become null and
void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
er Marshall,
Permit Technician
xc: Permit File No. PG07 -069
City of Tukwila
Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 -431 -3665
License Information
License
WASHIES971OB
Licensee Name
WASHINGTON ENERGY SERVICES CO
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
602320560
Ind. Ins. Account Id
SECRETARY
Business Type
CORPORATION
Address 1
2800 THORNDYKE AVE W
Address 2
City
SEATTLE
County
KING
State
WA
Zip
98199
Phone
2062824700
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
9/2/2003
Expiration Date
9/2/2007
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
Business Owner Information
Name
Role
Effective
Date
Expiration
Date
OLSON, CRAIG
PRESIDENT
09/02/2003
HEAGLE, RANDY
SECRETARY
09/02/2003
CHRISTIANSON,
STEVE
TREASURER
09/02/2003
OLSON, VERN
VICE
PRESIDENT
09/02/2003
Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Bond Information
Bond I Bond I
1 1 1
https:// fortress .wa.gov /lni/bbip /printer.aspx ?License= WASHIES971 OB 03/22/2007