HomeMy WebLinkAboutPermit PG07-090 - BOEING #9-90BOEING #9 -90 9725 E MARGINAL WY S PGO 7-090 Parcel No.: 0003400018 Address: Suite No: Tenant: Name: Address: Owner: Name: THE BOEING COMPANY Address: PO BOX 3703 M/S #1F-09 , SEATTLE WA Contact Person: Name: JERRY SCOTT Address: PO BOX 47983 , SEATTLE WA Contractor: Name: MACDONALD/NIILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA Contractor License No: MACDOFS980RU DESCRIPTION OF WORK: BUILDING RENOVATION OF 2 -STORY OFFICE BUILDING. WASTE/WATER TIES INTO EXISTING UTILITIES. 4 BATHROOMS, WATER HEATER (STEAM HEAT EXCHANGER), AND RAIN WATER SYSTEM. Value of Plumbing /Gas Piping: $765,200.00 Uniform Plumbing Code Edition: Fees Collected: $1,565.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet doc: UPC - 10/06 fir/ `rr' City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http : / /www.ci.tukwila.wa.us 9725 EAST MARGINAL WY S TUKW BOEING #9 -90 9725 EAST MARGINAL WY S , TUKWILA WA PLUMBING /GAS PIPING PERMIT International Fuel Gas Code Edition: FIXTURE TYPE AND OUANTITY * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 510 -7543 Phone: 206 -763 -9400 Expiration Date: 12/31/2008 Steven M Mullet, Mayor Steve Lancaster, Director PGO7 -090 05/24/2007 11/20/2007 2003 2003 Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 18 0 Water heater and/or vent 0 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 8 grease interceptors 0 0 Repair or alteration of water piping and/or water 16 treatment equipment 0 2 Repair or alteration of drainage or vent piping 0 27 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 10 Gas Piping 12 Gas piping outlets (0-5) 0 28 Gas piping outlets (6 +) 0 PG07 -090 Printed: 05-24 -2007 Permit Center Authorized Signatur ♦r City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.citukwila.wa.us 4e Permit Number: PG07 -090 Issue Date: 05/24/2007 Permit Expires On: 11/20/2007 Steven M Mullet, Mayor Steve Lancaster, Director Date: 2l 111- I hereby certify that I have read an• ex ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie • wi whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o pe c of wo . I am authorized to sign and obtain this plumbing /gas piping permit. Signature: Date: 57z `rM Print Name: ACP 4 L , 2 g - Se a T l This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC-10 /06 PG07 -090 Printed: 05-24 -2007 Parcel No.: 0003400018 Address: Suite No: Tenant: 13: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** BOEING #9 -90 1: ** *PLUMBING AND GAS PIPING * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 9725 EAST MARGINAL WY S TUKW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG07 -090 ISSUED 04/09/2007 05/24/2007 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 14: Contractor shall notify Public Works Utility Inspector at (206)433 -0179 of commencement and completion of BACKFLOW INSTALLATION WORK (2 DOMESTIC RPPAs and 1 Irrig DCVA, all inside mechanical rooms). 15: The domestic water RPPAs and irrigation DCVA shall be a WA State Department of Health approved backflow assemblies. All backflows shall be installed per manufacturer's recommendations. PG07 -090 Printed: 12 -18 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: Upon installation backflow prevention assemblies are to be tested by a certified tester. Thereafter annual test shall be performed at owners expense and copies of test results shall be submitted to Public Works Water Department. 17: All backflow prevention assemblies shall be installed per manufacturer's recommendations. doc: Cond -10/06 * *continued on next page ** PG07 -090 Printed: 12 -18 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: [ 6e4 L-13 e 1 % doc: Cond - 10/06 Date: / 2 /A / I PG07 -090 Printed: 12 -18 -2007 Parcel No.: 0003400018 Address: Suite No: Tenant: Name: Address: Plumbing doc: UPC -10/06 Sri►' City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206=431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us 9725 EAST MARGINAL WY S TUKW BOEING #9 -90 9725 EAST MARGINAL WY S , TUKWILA WA Owner: Name: THE BOEING COMPANY Address: PO BOX 3703 M/S #1F -09 , SEATTLE WA Contact Person: Name: JERRY SCOTT Address: PO BOX 47983 , SEATTLE WA Contractor: Name: MACDONALD/MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA Contractor License No: MACDOFS980RU PLUMBING /GAS PIPING PERMIT DESCRIPTION OF WORK: BUILDING RENOVATION OF 2 -STORY OFFICE BUILDING. WASTEWATER TIES INTO EXISTING UTILITIES. 4 BATHROOMS, WATER HEATER (STEAM HEAT EXCHANGER), AND RAIN WATER SYSTEM. Rev #1 after permit issued includes installation of 3" WILKINS 350 and 1.5" WILKINS Model 975 XL RPPA on domestic water & 2.5" irrigation/process water WILKINS Model 350 DCVA inside mechanical room. Value of Plumbing /Gas Piping: $765,200.00 Uniform Plumbing Code Edition: Fees Collected: $1,623.00 Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic 0 Dental unit, cuspidor 0 Dishwasher, domestic, with independent drain 0 Drinking fountain or water cooler (per head) 8 Food -waste grinder, commercial 0 Floor drain 16 Shower, single head trap 2 Lavatory 27 Wash fountain Receptor, indirect waste 0 Sinks 10 Urinals 12 Water Closet 28 International Fuel Gas Code Edition: FIXTURE TYPE AND QUANTITY 0 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 510 -7543 Phone: 206 -763 -9400 Expiration Date: 12/31/2008 Steven M Mullet, Mayor Steve Lancaster, Director PG07 -090 05/24/2007 02/04/2008 2003 2003 Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 18 Water heater and/or vent 0 Industrial waste treatment interceptor, including its trap and vent, except for kitchen type grease interceptors 0 Repair or alteration of water piping and/or water treatment equipment 0 Repair or alteration of drainage or vent piping 0 Medical gas piping system serving (1 -5) inlets /outlets for a specific gas 0 Medical gas piping (6 +) inlets /outlets 0 Gas Piping Gas piping outlets (0 -5) 0 Gas piping outlets (6 +) 0 PG07 -090 Printed: 12 -18 -2007 Permit Center Authorized Signature: I hereby certify that I have read and 4 xartined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie vin , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or - • erformance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Signature: doc: UPC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Print Name: g JGo Permit Number: PG07 -090 Issue Date: 05/24/2007 Permit Expires On: 02/04/2008 Steven M Mullet, Mayor Steve Lancaster, Director Date: l L1 i O C Date: / z-4/97o 7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG07 -090 Printed: 12 -18 -2007 Parcel No.: 0003400018 Address: Suite No: Tenant: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 9725 EAST MARGINAL WY S TUKW BOEING #9 -90 1: ** *PLUMBING AND GAS PIPING * ** PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: PG07 -090 ISSUED 04/09/2007 05/24/2007 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. PG07 -090 Printed: 05-24 -2007 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Print Name: ("4"Pitc--L> '. J D7i Date: 57Z ` PG07 -090 Printed: 05-24 -2007 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Soufhcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. 19[114---111 0 Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** I SITE LOCATION 1 King Co Assessor's Tax No.: (1003 A-10-0C- Site Address: 9 - 7 ZS CA SY /4 41U //v4L w4 y s Suite Number: Tenant Name: ! e ■ el AX c1 - '3 0 New Tenant: ❑ Yes Property Owners Name: I Fve,EJJt.tev rn„ & fk4./Y Mailing Address: PO ige,J( ?707 M/, 411= -69 E.,t,Ttt w4 igl Z City I CONTACT PERSON - who do we contact when your permit is ready to be issued State Zi Name: .kkQ 2∎l SC 617 (M e. ADwog- P fr'1 ) Mailing Address: Po q 7993 / E -Mail Address: . 66G-A. i*tc�Gi+ntl)Cv, C.G I GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: 1 ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Contact Person: E -Mail Address: Contractor Registration Number: Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: I ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Cr) fF .Fi JC-1/h) E rrl. Mailing Address: '&p Fr(i' - Aye 100 Contact Person: M tc.NF . S,' Tu ZA E -Mail Address: $o c P-Cw.ayt , covv% Q: Applications\Forms- Applications On Linen -2106 - Permit Application doe Revised: 9 -2006 btt Day Telephone: (Zo') 5- /O - SE/at-Le. LJ4 `1 .9I City State Zi Fax Number: ( Zo6 768 -y zs State State Floor: Zip Zip S �GA T -rL wA- 59 Io I City State Zi Day Telephone: Za - 6 - Z( -0748 Fax Number Zoto - (pZ'_ 377 %.No Page 1 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Q V Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste 1.110 b t 1 i41 16 f Z Clothes washer, domestic Floor drain go Sinks & icuAtkor Sc.roIL6 1 Dental unit, cuspidor Shower, single head trap Z.. Urinals 1Z Dishwasher, domestic, with independent drain Lavatory 27 Water Closet (3AC.eF1ow Q 3 Building sewer or trailer park sewer Rain water system — per drain (inside building) 1 8 Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Mailing Address: PO i3 c5 X 'y 1'183 Contact Person: 3f 22s( icOTT E -Mail Address: , e•rf . S Co++ @, wtauit , 1 ICV COW\ Contractor Registration Number: MAC-Pe) FS cigd R ) Building Use (per Int'I Building Code): OCT-IC Occupancy (per Int'l Building Code): (i EooP B Utility Purveyor: Water: Q:Upplications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 - 2006 bh PLUMBING AND GAS PIPING PERMIT INFORMATION - 206- 431 -3670 Company Name: ItA etGIpv v4LIN 1 ' 1 A i t t.Eet rACALIF4 . 5(51..o T 'O&M Valuation of Plumbing work (contractor's bid price): $ 16 Z C) Valuation of Gas Piping work (contractor's bid price): $ WA (� n Scope of Work (please provide detailed information): tot !) re tic�v4T 0.. O /1 r '') �"I" 'v (,4 ssk' /LA JJ ( 4-1 os t�tv 2,x K +tv to 4-(1 t 1-1 es . s-Fe't,vv., ,ea4' �c l..At•u•� ke K wc— S s f . bat,✓oo►. Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: 5 i E t, r& )A R�rLilo City State Zip Day Telephone: (Zdo � S O - 76 -4 43 Fax Number: C i; 768 Expiration Date: 1 Z/? )/n , r l L , r_ , / L,,/ W a'1 Q✓ kee W r Sewer: Page 5 of 6 Mailing Address: o '410 Print Name: S __O, �� r•_ QMpplicationaorms- Applications On Line\3 -2006 - Permit Application.dx Revised: 9 -2006 bh PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration otPlan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbline Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN ' OR AUTHORIZ Signature: Day Telephone: Date: / /c_ (Z00 57c — 7S City State 8 Zip Date Application Accepted: ff ll� log Date Application Expires: I Vi I Staff Initials: Page 6 of6 Parcel No.: 0003400018 Address: Suite No: Applicant: BOEING #9 -90 Receipt No.: R07 -02779 Initials: JEM User ID: 1165 Payee: TRANSACTION LIST: Type Method Description Payment Check 1535 ACCOUNT ITEM LIST: Description doe: Receiot -06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.atukwi/a.wa.us 9725 EAST MARGINAL WY S TUKW MACDONALD- MILLER FACILITY SOLUTIONS, INC. Account Code PLUMBING - NONRES 000/322.100 RECEIPT Permit Number: Status: Applied Date: Issue Date: Payment Amount: Payment Date: Balance: Amount 58.00 Current Pmts 58.00 Total: $58.00 $58.00 PG07 -090 ISSUED 04/09/2007 05/24/2007 12/18/2007 09:20 AM $0.00 6214 12/18 9710 TOTAL 58.00 Printed: 12- 18-2007 Receipt No.: R07 -00938 TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description PLUMBING - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431 -3665 Web site: http: / /www. ci. tukwila. wa. us RECEIPT Parcel No.: 0003400018 Permit Number: PG07 -090 Address: 9725 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 04 /09/2007 Applicant: BOEING #9 -90 Issue Date: Initials: ]EM Payment Date: 05/24/2007 11:28 AM User ID: 1165 Balance: $0.00 Payee: MACDONALD- MILLER FACILITY SOLUTIONS, INC. Amount Payment Check 1285 1,288.00 Account Code Current Pmts 000/322.100 1,288.00 Total: $1,288.00 Payment Amount: $1,288.00 8597 05/25 9716 TOTAL 1288.00 (inc.! RAr.Rint -(M Printed: 05-24 -9(107 Doc: RECSETS -06 RECEIPT NO: R07 -00535 Initials: JEM User ID: 1165 SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us SET RECEIPT Payee: MACDONALD- MILLER FACILITY SOLUTIONS, INC. M07 -067 4,371.83 PG07 -090 277.00 TOTAL: 4,648.83 000/345.830 4,648.83 TOTAL: 4,648.83 SET ID: S000000725 SET NAME: Tmp set/Initialized Activities TRANSACTION LIST: Type Method Description Amount Payment Check 1238 4,648.83 TOTAL: 4,648.83 Payment Date: 04/09/2007 Total Payment: 4,648.83 Account Code Current Pmts Probe : Type of Inspection: Address: S �1 9ate Called: Special Instructions: Date 2/ Wanted: / Z/( (��} F m. Requester: Phone No: _ .7 - - 6 wq INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION NO. 1� 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Approved per applicable codes. .K1 COMMENTS: ?er.14 eipt No.: 'Date: Date: f/e? 0 REINSPECTION FIE REARED. Prior to inspection, fee must be id at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. r�Gv 7 -�i U Corrections required prior to approval. COMMENTS: Typgjafinspectiorel 7 , "—I it (.. /-* / j , j 6 Add 75 p Called: Special Instructions: Date Want d: /7 71 a. . Requester: Phone No: ...2. /5 F l aw - 1)- 7 ,itis l.q. Ai 6 c A-H 1 4 ( / ri- i AW ---) 0 ° ,_...) 2 nid ,c(oc./)-- s-n /us / 6-4 / 07209A 61-r 4 1 ( 1 a ,A.,c, r loov (Aid-k4 &..s 7 / c; b--, ,F _AJd - 7 / . . . - - lq-A-te / 7.4 if -rc,, /,c4( , i f) A) ) Aid FlOtOy ,r1-s -1 0 4 1..,.7 4 (C 2 ('td -,-- .5..) fr--- Project: /2 00e aL ".'- 5 6 Typgjafinspectiorel 7 , "—I it (.. /-* / j , j 6 Add 75 p Called: Special Instructions: Date Want d: /7 71 a. . Requester: Phone No: P6O-SV INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 Approved per applicable codes. Corrections required prior to approval. ( /41411 / rtsj:iect : Dz $ .00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be Id at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project �t �� o,c 4;1-4. - S 0 Type of Inspection; p vas, h , AJ U A d es s: 7 25 /7V ?/? //U /,) Date Called: / Special Instructions: Date W ted: i —e —Q-7 a.m p.m. Requester: Phone No: INSPECTION RECORD ,Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (20 • )431 -3 COMMENTS: ,?N74` %,-✓ � Inspe �' tor: ratep_ U _ 8.00 REINSPECTION E REQUIRE. Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. ipt No.: 'Date: Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: p Inspectipn: \ A / - i: U t f rI (1) sg S (/ / / (jdlI - / /4CSi° 5 �: Li / kI, c.P v/ el i't, S" / `7 - 'rt/ ( p /fi /y")i tk S S- -- /14r''V2t'1y Pho e X46 - 7 ss - /v076' y h' 1z,4 iiefi r ,,, ,‹, N Proje 0 ,P / - - 'a Inspectipn: \ A / - i: U t f rI ss: Ad e 72 s 9/I - �l 2 ii ate C alled: � / Special Instructions: Date need: W 5_ -7 - a.m. Requester: Pho e X46 - 7 ss - y INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. n • ector: 'Receipt No.: INSPECTION RECORD Retain a copy with permit Date , G (206)431 -36 .00 ' EINSPECTION FEE REQU RED. rior to inspection. fee must be p : id . 6300 Southcenter Blvd.. Site 1 0. Call the schedule reinspection. 'Date: -t 2 42.4111r 5�`': COMMENTS: Type o nspecti n: Address: _ o 72 .5 c " ?� �ti� / ( _ Y Requester: Phone No: ,266 25 s --- (`7/4/6 -ff S -i!J ✓/ (X 1/I") / Lc, I/ 4- Pro' Type o nspecti n: Address: _ o 72 .5 c " ?� �ti� / Date Called: Special Instructions: Date ' nted: a. m` / 2 3_ O-) p.m Requester: Phone No: ,266 25 s --- (`7/4/6 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. ❑ Corrections required prior to approval. spect (Rec -' . No.: EINSPECTION FEE REQUIR •. Prio to inspection, fee must be 6300 Southcenter Blvd., Suite 00. 11 the schedule reinspection. Date: 'Date: (206)431 -36 7 z3 4 ' A: _ �Y► Proype iitl 67 _ 04, — cI of Inspection: 0 7G90 � C) / t // Ad ress: C 72_5 e m ,9Q � �•u A / Date Calle ;2) Special Instructions: l oci, , / 02,4a4one Date Wanted: ^� �Z - /-- / a.m. .. Requester: No:, -2.S-,5-- INSPECTION RECORD Retain a copy with permit INSPECTIOR(NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT (2 i 6)431 -3670 El Approved per applicable codes. El Corrections required prior to approval. COMMENTS: n LIJ 4 ( U 1/leAt/ C/71--7 / S $58.00 REINSPECTIOIEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Projef4: , -44 Type of Inspection: (,fc'N1 I,Jd ckl ove Address: c l 7 2 5 Date Called: Special Instructions: — ' Date Wanted: (a.m. a Requester: Phone No: 0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 LJ Approved per applicable codes. COMMENTS: h,e_ 7h A !',( s 4./ z 'Inspector/ 'Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit • . 1 (206)431-3670 El Corrections required prior to approval. Project: RO e7AIG ' -co Type of Inspection: /- (Ain7, Address: , 5 72 5 , /77r0 /4 Date Called: /4.? 5 — Special Instructions: DateVanted: C_ P.m. Requester: Phone N INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PER :4 ,„ 2 • 6)431-3670 Approved per applicable codes. COMM ENTS: 1 0 t - 58.00 REINSPECT ON FEE paid at 6300 Southcenter Blv Corrections required prior to approval. QUIRE:). Prior to inspection, fee must be ., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Y G4 'Date: I z P . t Type of Inspgsti_ on; P � ai A•; es • E • ii i 4 4 _A. Date Called: a Special Instructions: Date Wanted: 1 � �� �f �/ •m. Requester: liA Sat Pht No: // � -7(-343 - INSPECTION RECORD Retain a copy with permit 07 -' PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: l 'Inspector: 'Date: $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: (Date: cam:: te. INITIAL TEST PASSE FAIL ❑ DCVA/RPBA CHECK DCVA/RPBA CHECK RPBA PVBA SVBA AIR INLET OPENED AT PSID VALVE NO. 1 VALVE NO. 2 OPENED AT 3. Y PSID #1 CHECK 7.5 PSID LEAKED 0 TIGHT j , 7.5 PSID LEAKED ❑ TIGHT �J 7761 PSID DID NOT OPEN 0 AIR GAP OK? ye NEW PARTS AND REPAIRS CLEAN REPLACE PART O O CLEAN REPLACE PART ❑ o CLEAN REPLACE PART o o CHECK VALVE HELD AT PSID 0 ❑ ❑ o ❑ O LEAKED 0 o 0 0 0 0 0 o ❑ O ❑ O 0 CLEANED 0 REPAIRED o 0 0 0 0 0 ❑ TEST AFTER REPAIRS PASS ❑ FAIL ❑ TIGHT ❑ LEAKED ❑ PSID TIGHT ❑ LEAKED ❑ PSID OPENED AT PSID AIR INLET PSID #1 CHECK PSID CHK VALVE PSID MacDonald- Miller FACILITY SOLUTIONS Backflow Prevention Assembly Test Report ASSEMBLY ID://6 4/S171 L. L PASSED ANNUAL TEST: YES 0 NO ❑ NAME OF PREMISE gDE.Z4/6 9 -F0 Cam. COMMERCIALXRESIDENTIAL ❑ SERVICE ADDRESS 97 35 ingr rcll WQq S. CITY ;LA ZIP ?Rla.Y CONTACT PERSON !FA fPM C-(kt J �Gs 5 hone ( ) Fax ( ) LOCATION OF ASSEMBLY E5 li6cEA/V /G4 L Room F MC. I DOWNSTREAM PROCESS AO/YE577G113C(PO4 SS DCVA O RPBA & PVBA O OTHER: NEW INSTALL1 EXISTING ❑ REPLACEMENT ❑ OLD SER. # PROPER INSTALLATION? YES ec NO ❑ MAKE OF ASSEMBLY MODEL 775XL. SERIAL NO.A75c2603 SIZE I AIR GAP INSPECTION: Required minimum air gap separation provided? Yes ❑ No ❑ Detector Meter Reading /(/ /fit LINE PRESSURE jpc CONFINED SPACE? 4/0 CERT. NOB DATE /2-/' REMARKS: TESTERS SIGNATU TESTERS NAME (PRINT C J Phone'4 / 5 ' / 6 S ' 7 REPAIRED BY: DATE FINAL TEST BY: CERT. NO. DATE CALIBRATION DATE Q l,o, 07 GAUGE # if 7/ MODEL TX-71D SERVICE RESTORED? YES k NO ❑ / certify that this report is accurate, and / have used WAC 246 -290 -490 approved test methods and test equipment. INITIAL TEST PASS FAIL O DCVA/RPBA CHECK DCVA/RPBA CHECK RPBA PVBA SVBA VALVE NO. 1 VALVE NO. 2 OPENED AT PSID AIR INLET OPENED AT PSID #1 CHECK PSID LEAKED ❑ TIGHT QS �' PSID DID NOT OPEN 0 LEAKED • TIGHT pi / 8 PSID AIR GAP OK? NEW PARTS AND REPAIRS CLEAN REPLACE PART ❑ ❑ CLEAN REPLACE PART O O CLEAN REPLACE PART ❑ 0 CHECK VALVE HELD AT PSID ❑ ❑ ❑ 0 0 0 LEAKED ❑ ❑ 0 0 0 ❑ 0 ❑ 0 o ❑ o ❑ CLEANED o REPAIRED ❑ O 0 ❑ o O 0 TEST AFTER REPAIRS PASS ❑ FAIL o TIGHT ❑ LEAKED ❑ PSID TIGHT ❑ LEAKED ❑ PSID OPENED AT PSID AIR INLET PSID #1 CHECK PSID CHK VALVE PSID 4 Z2) MacDonald- Miller FACILITY SOLUTIONS Backflow Prevention Assembly Test Report ASSEMBLY ID: /vela �/t/ i l LL PASSED ANNUAL TEST: YES 0 NO 0 NAME OF PREMISE 806T 4,1g 7:10 RLD 6 SERVICE ADDRESS 97 3 S mqr (rjQ/ War S. CONTACT PERSON I'ALP/. 5 -s ! Phone LOCATION OF ASSEMBLY 6 L 7.40 /si / r6 DOWNSTREAM PROCESS =RE-/6AT! NEW INSTALL EXISTING ❑ REPLACEMENT O OLD SER. # MAKE OF ASSEMBLY WILK IN 5 MODEL 350 AIR GAP INSPECTION: Required minimum air gap separation provided? Yes 0 No 0 REMARKS: TESTERS SIGNATU TESTERS NAME (PRIM f O 5=jQ /1.1e/ REPAIRED BY: FINAL TEST BY: CALIBRATION DATE 7 1/0107 GAUGE # /7' COMMERCIALLRESIDENTIAL O CITYgv &tal Q ZIP 97/ Fax ( ) DCVA., RPBA ❑ PVBA O OTHER: PROPER INSTALLATION? YESA 0 SERIAL NO. fa 337 8 SIZEo7, Detector Meter Reading /VA LINE PRESSURE 6 5 CONFINED SPACE? /VD CERT. NOB DATE 010 7 Phone 6 2S5- y6 89 DATE CERT. NO. DATE MODELrR ?.b SERVICE RESTORED? YESJ NO ❑ / certify that this report is accurate, and / have used WAC 246 -290 -490 approved test methods and test equipment. INITIAL TEST PASS PQ FAIL ❑ DCVA/RPBA CHECK DCVA/RPBA CHECK RPBA PVBA SVBA VALVE NO. 1 VALVE NO. 2 OPENED AT 3.3 PSID AIR INLET OPENED AT PSID #1 CHECK g 7 PSID LEAKED • TIGHT Et LEAKED • TIGHT t DID NOT OPEN ❑ g, PSID / - PSID f ` 6R t, AIR GAP OK? yP-s NEW PARTS AND REPAIRS CLEAN REPLACE PART ❑ ❑ CLEAN REPLACE PART ❑ ❑ CLEAN REPLACE PART ❑ ❑ CHECK VALVE HELD AT PSID ❑ ❑ ❑ ❑ ❑ ❑ LEAKED ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 0 ❑ ❑ ❑ CLEANED ❑ REPAIRED ❑ ❑ ❑ ❑ ❑ ❑ ❑ TEST AFTER REPAIRS PASS ❑ FAIL ❑ TIGHT ❑ LEAKED ❑ PSID TIGHT ❑ LEAKED ❑ PSID OPENED AT PSID AIR INLET PSID #1 CHECK PSID CHK VALVE PSID 4r 2ZDO MacDonald - Miller FACILITY SOLUTIONS Backflow Prevention Assembly Test Report ASSEMBLY ID: PE@ _T-/(/S74 LL PASSED ANNUAL TEST: YES ❑ NO ❑ NAME OF PREMISE RDE - X/V(a 9 JD 8Lb COMMERCIAL4RESSIDENTIAL ❑ SERVICE ADDRESS 973 5 E, /nor?' j ql G(WQ y S. crr'f7 Kw,iq ZIP? Y /cW TA PERSON A LPb/- s Loge ! Phone ( ) Fax ( ) LOCATION OF ASSEMBLY uesr, - Cl/AN /CAL R0/4 / /c DOWNSTREAM PROCESS 2)DmArS77 . NEW INSTALLK EXISTING ❑ REPLACEMENT ❑ OLD SER. # MAKE OF ASSEMBLY tag G k /4/ s MODEL ,3 75 DCVA ❑ RPBA/iit PVBA ❑ OTHER: PROPER INSTALLATION? YES l NO ❑ SERIAL NO.L 36355 SIZE3.D AIR GAP INSPECTION: Required minimum air gap separation provided? Yes ❑ No ❑ Detector Meter Reading /WA LINE PRESSURE 1()57 CONFINED SPACE? 1'V TESTERS SIGNATU CERT. NO. <S iNW DATE /;--/49-07 TESTERS NAME (PRI NT):7∎08ertr Af 7 /LI L?GL./ Phone S -ye 8? REPAIRED BY: DATE FINAL TEST BY: CERT. NO. DATE CALIBRATION DATE ' I/O I D7 GAUGE # / 9 7/ MODELT/' ? ?2) SERVICE RESTORED? YESp -NO ❑ / certify that this report is accurate, and / have used WAC 246 - 290 -490 approved test methods and test equipment. REMARKS: P REVISION NO. CORRECTION! FEATURES LTR# Sizes:❑ 2 1/2 ""3" ❑ 4" ❑ 6" ❑ 8" ❑ 10" Maximum working water pressure 175 PSI Maximum working water temperature 140 °F Hydrostatic test pressure 350 PSI End connections (Grooved for steel pipe) AWWA C606 (Flanged)ANSI B16.1 Class 125 OPTIONS (Suffixes can be combined) O - with NRS shut -off valves (standard) ❑ FS - with cast iron wye type strainer (flanged only) FSC - with epoxy coated wye type strainer (flanged only) ❑ G - with groove end gate valves ❑ GF - with grooved inlet gate connection and flanged outlet gate connection ❑ FG - with flanged inlet gate connection and grooved outlet gate connection ❑ L - less shut -off valves (flanged body connections) ❑ MS - with Integral Relief Valve Monitor Switch O OSY - with OS & Y gate valves ❑ PI - with Post Indicator Gate Valve (4 " -10 ") ACCESSORIES ❑ Repair kit (rubber only) ❑ Thermal expansion tank (Model WXTP) ❑ OS & Y Gate valve tamper switch (OSY -40) % Air gap (Model AG) ❑ Electronic Solenoid Timer (Model EST) ❑ QT -SET Quick Test Fitting Set ❑ Test Cock Lock (Model TCL24) CCIE r r L t' BASS b:4 DEC 1 City Of BUILDING' Page 1 of 2 DIMENSIONS & WEIGHTS (do not include pkg.) !&oio ATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of contami- nated water into the potable water supply. The Model 375 provides protection where a potential health hazard exists. STANDARDS COMPLIANCE ( unless otherwise noted, sizes 2 1/2" thru 10 ") • ASSE® Listed 1013 • IAPMO® Listed • CSA® Certified (2 1/2" thru 8 ") • AVWVA Compliant C511 • FM®Approved • UL® Classified • C -UL® Classified • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California MATERIALS Main valve body Access covers Coatings Internals Fasteners Seal rings 0-rings Springs Sensing line MODEL 3750SYG SHOWN ABOVE RECEivE1 DEC 12 2007 PERMI1 CENTEh Ductile Iron ASTM A536 Grade 4 Ductile Iron ASTM A536 Grade 4 FDAApproved fusion epoxy finish Stainless steel, 300 Series NORYLTMI, NSF Listed Stainless Steel, 300 Series EPDM (FDA approved) Buna Nitrile (FDA approved) Stainless Steel, 300 Series Stainless Steel, braided hose LIE iCOINy It No. E 8„ Relief Valve • I t - - - • •' t2 2.75 sq. iin. ti 6q � ll ts _ �� G alit Attention: Model 375 (flange body) and Model 375A - (grooved body) have differ- ent lay lengths. _ MODEL SIZE mm DWENSIONS (approximate) in. A mm B LESS GATE VALVES in. mm in. c mm in. D mm E OS&Y OFB4 1. mm E OS&Y CLOSED h. mm E HRS GATE In. mm n. F mm G in. mm n. H mm WEIGHT WITHOUT GATE VALVES bs. kg WITH NRS VALVES bs. kg WITH OS&Y GATE VALVES bs. kg (Patent No 5,913,331) 212 3 4 6 8 10 65 80 100 150 200 31 787 32 813 37 5/8 956 44 3/4 1137 60 3/4 1543 250 63 3/4 15 7/8 15 7/8 19 12 2312 37 3/4 403 403 495 597 959 71/4 71/4 8 10 11 1619 37 3/4 959 11 184 184 203 254 279 279 33/4 33/4 412 6 10 10 95 95 114 152 254 254 163/8 18 7/8 22 3/4 301/8 37 3/4 416 479 578 765 959 13 7/8 155/8 181/4 23 3/4 291/4 352 397 464 603 743 11 3/8 123/8 14 3/4 19 2212 289 314 375 483 572 912 91/2 11 123/8 153/8 241 241 279 314 391 83/8 8 3/8 71/4 91/4 16 3/4 213 213 184 235 426 41 1/4 42 3/4 52 3/4 62 3/4 85 1048 1086 1340 1594 2159 60 60 98 175 377 45 3/4 1162 35 3/8 899 2612 673 153/8 391 163/4 426 931/4 2369 407 27.2 27.2 44.5 79.5 171 162 184 278 459 829 73.5 83.5 126.2 208.4 376.4 185 1167 530 170 190 288 475 853 1225 772 86.3 130.8 215.6 387.3 556 Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 3" 115 173 230 346 4" 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 5288 20 15 10 5 0 FLOW CHARACTERISTICS MODEL 375 2 1/2 ", 3" & 4" (STANDARD & METRIC) FLOW RATES (Us) 12.6 25.2 37.9 2 1/2" (65mm) TYPICAL INSTALLATION '.ocal codes shall govern installation requirements. Unless itherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. 3" (80mm) 200 400 FLOW RATES (GPM) MODEL 375 6 ", 8" & 10" (STANDARD & METRIC) FLOW RATES (I/s) 63.1 126.2 1000 2000 FLOW RATES (GPM) ORated Flow (Established by approval agencies) 600 189.3 3000 OUTDOOR INSTALLATION RECEIVED DEC 12 2007 t ERMULENTEh 138 _4" (100mm) = y 104 0 69 S 35 800 0- DIRECTION OF FLOW C=1> INDOOR INSTALLATION (375GF) SPECIFICATIONS The Reduced Pressure Principle Backflow Prevention Assembly shall be ASSE® Listed 1013, and supplied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NORYLTMt, the stem shall be stainless steel (ASTM A276) and the seat disc elastomers shall be EPDM. The checks and the relief valve shall be accessible for maintenance without removing the device from the line. The Reduced 'ressure Principle Backflow Prevention Assembly shall be a WILKINS Model 375. Page 2of2 WILKINS a Zum company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238 -7100 Fax:805/238 - 5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905 /405 - 8272 Fax:905/405 - 1292 Product Support Help Line: 1- 877 - BACKFLOW (1- 877 - 222 -5356) • Website: http: / /www.zum.com 252.4 138 0. 104 ) 0 69 W o: 35 4000 0- 6" (150mm) 8" (200mm) 10" (250mm)- 20 15 10 5 0 FLOW CHARACTERISTICS MODEL 375 2 1/2 ", 3" & 4" (STANDARD & METRIC) FLOW RATES (Us) 12.6 25.2 37.9 2 1/2" (65mm) TYPICAL INSTALLATION '.ocal codes shall govern installation requirements. Unless itherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. 3" (80mm) 200 400 FLOW RATES (GPM) MODEL 375 6 ", 8" & 10" (STANDARD & METRIC) FLOW RATES (I/s) 63.1 126.2 1000 2000 FLOW RATES (GPM) ORated Flow (Established by approval agencies) 600 189.3 3000 OUTDOOR INSTALLATION RECEIVED DEC 12 2007 t ERMULENTEh 138 _4" (100mm) = y 104 0 69 S 35 800 0- DIRECTION OF FLOW C=1> INDOOR INSTALLATION (375GF) SPECIFICATIONS The Reduced Pressure Principle Backflow Prevention Assembly shall be ASSE® Listed 1013, and supplied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NORYLTMt, the stem shall be stainless steel (ASTM A276) and the seat disc elastomers shall be EPDM. The checks and the relief valve shall be accessible for maintenance without removing the device from the line. The Reduced 'ressure Principle Backflow Prevention Assembly shall be a WILKINS Model 375. Page 2of2 WILKINS a Zum company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238 -7100 Fax:805/238 - 5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905 /405 - 8272 Fax:905/405 - 1292 Product Support Help Line: 1- 877 - BACKFLOW (1- 877 - 222 -5356) • Website: http: / /www.zum.com 252.4 138 0. 104 ) 0 69 W o: 35 4000 0- Model 975XL Reduced Pressure Principle Assembly FEATURES Sizes: ❑ 3/4" ❑ 1" ❑ 1W 1 ❑ 2" Maximum working water pressure Maximum working water temperature Hydrostatic test pressure End connections Threaded OPTIONS (Suffixes can be combined) ❑ ❑ L ❑ U ❑ MS ❑ P ❑ S ❑ BMS ❑ FDC ❑ TCU ❑ V ❑ SE ❑ FT - with full port QT ball valves (standard) - less ball valves - with union ball valves - with integral relief valve monitor switch - for reclaimed water systems - with bronze "Y" type strainer - with battery operated monitor switch - with fire hydrant connection; 2" only - with test cocks up - with union swivel elbows - with street elbows - with integral male 45 flare SAE test fitting ACCESSORIES xr Airgap(ModelAG) ❑ Repair kit (rubber only) ❑ Thermal expansion tank (Model WXTP) ❑ Soft seated check valve (Model 40) ❑ Shock arrester (Model 1250) ❑ QT-SET Quick Test Fitting Set ❑ Ball valve handle locks ❑ Test Cock Lock (Model TCL24) DIMENSIONS & WEIGHTS (do not include pkg.) Page 1 of 2 175 PSI 180 °F 350 PSI ANSI B1.20.1 APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of contami- nated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists. STANDARDS COMPLIANCE • ASSE® Listed 1013 • IAPMO® Listed • UL® Classified (less shut -off valves orwith OS&Y valves) • C-UL® Classified • CSA® Certified • AVWVA Compliant C511 • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southem Califomia MATERIALS Main valve body Access covers Fasteners Elastomers Polymers Springs Cast Bronze ASTM B 584 Cast Bronze ASTM B 584 Stainless Steel, 300 Series Silicone (FDAApproved) Buna Nitrite (FDAApproved) DEC 12 2007 Norylim, NSF Listed Stainless steel, 300 series PERMIT CENTS FI 91113 ,'ECL JVEL Relief Valve discharge port: 3/4" - 1" - 0.63 sq. in. 1 1/4" - 2" - 1.19 sq. in. MODEL SIZE in. mm 3/4 1 1 1/4 1 1/2 2 20 25 32 40 50 DIMENSIONS approximate) in. A mm 12 13 17 17 3/8 18 1/2 305 330 432 441 470 A UNION BALL VALVES in. mm 14 14 1/4 19 20 21 1/4 356 362 483 508 540 B LESS BALL VALVES in. mm 7 3/4 7 3/4 1015/16 1015/16 1015/16 197 197 278 278 278 c in. mm 2 1/8 2 1/8 2 3/4 2 3/4 2 3/4 _ 54 54 70 70 70 D in. mm 3 3 31/2 31/2 3 1/2 76 76 89 89 89 E in. mm 31/2 3 1/2 5 5 5 89 89 127 127 127 F in. mm 5 5 6 3/4 6 3/4 6 3/4 127 127 171 171 171 in. G mm 15 3/4 17 3/4 22 231/8 25 1/2 400 451 559 587 648 WEIGHT LESS BALL VALVES lbs. kg 10 10 22 22 22 4.5 4.5 10 10 10 WITH BALL VALVES lbs. kg 12 14 28 28 34 5.5 6.4 12.7 12.7 15.4 DOCUMENT #: REVISION: BF -975XL I. 1/06 Capacity thru Schedule 40 Pipe P ipe size 5 ft /sec 7.5 ft /sec 10 ft /sec 15 ft /sec 1/8" 1 1 2 3 1/4" 2 2 3 5 3/8" 3 4 6 9 1 /2" 5 7 9 1 4 3/4" 8 12 17 25 1" 13 20 27 40 1 1/4" 23 35 47 70 1 1/2" 32 48 63 95 2" 52 78 105 167 a 20 0) 9 15 w 10 i MODEL 975XL 3/4 ", 1 ", 1 1/4 ", 1 1/2" & 2" (STANDARD & METRIC) FLOW RATES (Us) 1.26 2.52 3.8 5.0 20 3/4" (20m� 1' (25mm� U) a 5 5 20 40 60 80 0 0 TYPICAL INSTALLATION Local codes shall govern installation re- quirements. To be installed in accor- dance with the manufacturers' instruc- tions and the latest edition of the Uni- form Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above ad- equate drains with sufficient side clear- ance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. CENTRAL STATION ALARM PANEL Page 2of2 1 s • • 12' MIN. 30' MAX. • FLOOR J f FLOOR DRAIN DIRECTION OF FLOW INDOOR INSTALLATION (Shownw/optional BMS) FLOW CHARACTERISTICS 15 10 3.2 50 FLOW RATES (GPM) 0 Rated Flow (Established by approval agencies) 6.3 PROTECTIVE ENCLOSURE 100 9.5 150 12.6 200 DIRECTION OF FLOW INLET SHUT -OFF OUTDOOR INSTALLATION 15.8 137 t in 103 w 69 35 a 250 SPECIFICATIONS The Reduced Pressure Principle Backflow Preventer shall be ASSE® Listed 1013, rated to 180 °F and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat ring and all internal polymers shall be NSF® Listed NorylTm and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter and integral monitor switch. The Reduced Pressure Principle Backflow Preventer shall be a WILKINS Model 975XL. WILKINS a Zum company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805 /238 -7100 Fax:805/238 -5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905 /405 -8272 Fax:905/405 -1292 Product Support Help Line: 1- 877- BACKFLOW (1 -877- 222 -5356) • Website: http: //www.zurn.com RECEIVE[ DEC 12 2007 PERMIT CENTEI 1 1/4' (32mm) Omm 2" (50mm) - a 20 0) 9 15 w 10 i MODEL 975XL 3/4 ", 1 ", 1 1/4 ", 1 1/2" & 2" (STANDARD & METRIC) FLOW RATES (Us) 1.26 2.52 3.8 5.0 20 3/4" (20m� 1' (25mm� U) a 5 5 20 40 60 80 0 0 TYPICAL INSTALLATION Local codes shall govern installation re- quirements. To be installed in accor- dance with the manufacturers' instruc- tions and the latest edition of the Uni- form Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above ad- equate drains with sufficient side clear- ance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. CENTRAL STATION ALARM PANEL Page 2of2 1 s • • 12' MIN. 30' MAX. • FLOOR J f FLOOR DRAIN DIRECTION OF FLOW INDOOR INSTALLATION (Shownw/optional BMS) FLOW CHARACTERISTICS 15 10 3.2 50 FLOW RATES (GPM) 0 Rated Flow (Established by approval agencies) 6.3 PROTECTIVE ENCLOSURE 100 9.5 150 12.6 200 DIRECTION OF FLOW INLET SHUT -OFF OUTDOOR INSTALLATION 15.8 137 t in 103 w 69 35 a 250 SPECIFICATIONS The Reduced Pressure Principle Backflow Preventer shall be ASSE® Listed 1013, rated to 180 °F and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat ring and all internal polymers shall be NSF® Listed NorylTm and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter and integral monitor switch. The Reduced Pressure Principle Backflow Preventer shall be a WILKINS Model 975XL. WILKINS a Zum company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805 /238 -7100 Fax:805/238 -5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905 /405 -8272 Fax:905/405 -1292 Product Support Help Line: 1- 877- BACKFLOW (1 -877- 222 -5356) • Website: http: //www.zurn.com RECEIVE[ DEC 12 2007 PERMIT CENTEI FEATURES Sizes: l{2 1/2" ❑ 3" ❑ 4" ❑ 6" Maximum working water pressure Maximum working water temperature Hydrostatic test pressure End connections (Grooved for steel pipe) (Flanged) FS FSC G GF FG L OSY PI ACCESSORIES ❑ Repair kit (rubber only) ❑ Thermal expansion tank (Model WXTP) ❑ OS & Y Gate valve tamper switch (OSY 40) ❑ Test Cock Lock (Model TCL24) ❑ 8" ❑ 10" 0 12" 175 PSI 140 °F 350 PSI AWWA C606 ANSI B16.1 Class 125 OPTIONS (Suffixes can be combined) O - with NRS shut -off valves (standard) ❑ - with cast iron wye type strainer (flanged only 2-1/2"-10") ❑ - with epoxy coated wye type strainer (flanged only 2-1/2"-10") ❑ with groove end gate valves (2-1/2" - 10") O with grooved inlet gate connection and flanged outlet gate connection (2 -1/2" - 10") ❑ - with flanged inlet gate connection and grooved outlet gate connection (2 -1/2" - 10") ❑ - less shut -off valves (flanged body connections) ❑ - with OS & Y gate valves O - with Post Indicator Gate Valve (4 " -12 ") G DIMENSIONS & WEIGHTS (do not Include pkg.) APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply.The Model 350 shall provide protection where a potential health hazard does not exist. STANDARDS COMPLIANCE : (Sizes 21/2 " -10" Horiz. & Vert) (Size 12" horizontal) ASSE® Listed 1015 CSA® Certified (2 -1/2" - 10 ") IAPMO® Listed • AWWA Compliant C510 • UL® Classified • C -UL® Classified • FM ®Approved (2 -1/2" - 10") • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southem California (2 -1/2" - 10 ") MATERIALS Main valve body Access covers Coatings Internals Fasteners Seal ring 0 -ring Springs A MODEL 3500SYG SHOWN ABOVE Ductile Iron ASTM A 536 Grade 4 Ductile Iron ASTM A 536 Grade 4 FDA Approved fusion epoxy finish Stainless steel, 300 Series NORYLTM, NSF Listed Stainless Steel, 300 Series EPDM (FDA approved) Buna Nitrile (FDA approved) Stainless Steel, 300 Series iECEI IEL DEC 12 2007 PERMIT CENTEF Attention: Model 350 (flange body) and 350A (grooved body) have different lay lengths. SIZE in. mm 21/2 3 4 6 8 10 12 65 80 100 150 200 250 300 DIMENSION (approximate) in. A mm 31 32 37 5/8 44 3/4 60 3/4 63 3/4 661/4 791 816 956 1137 1543 1619 1683 B LESS GATE VALVES in. m 157/8 15 7/8 19 1/2 231/2 37 3/4 373/4 38 403 403 495 597 959 959 965 c in. m 33/4 33/4 4 1/2 6 10 10 10 95 95 114 152 254 254 254 D in. m 71/4 71/4 8 10 11 11 12 184 184 203 254 279 279 E OS&Y OPEN in. m 16 3/8 18 7/8 22 3/4 301/8 373/4 45 3/4 531/8 416 479 578 765 959 1162 1349 E OS&Y CLOSED in. mm 13 7/8 15 5/8 181/4 23 3/4 291/4 35 3/8 405/8 352 397 464 603 743 899 1032 E NRS GATE in. mm 113/8 123/8 143/4 19 221/2 261/2 30 289 314 375 483 572 673 762 F in. mm 31/2 31/2 7 81/2 81/2 9 89 89 152 178 216 216 229 in. G mm 41 1/4 42 3/4 52 3/4 623/4 85 931/4 Na 1048 1086 1340 1594 2159 2369 Na WEIGHT WITHOUT GATE VALVES lbs. kg 53 53 91 165 358 388 447 24.1 24.1 41.3 74.9 162.5 1762 202.8 WITH NRS GATE VALVES bs. kg 155 177 271 449 810 1148 1493 70.4 80.4 123 203.8 367.7 5212 6772 WITH OS&Y GATE VALVES bs. kg 163 183 281 465 834 1206 1607 74 83 127.6 211 378.6 547.5 729 Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft /sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 3" 115 173 230 346 4" 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 5288 0 15 n aN 10 CO co 0 5 a 0 0 0 0 TYPICAL INSTALLATION 2 -1/2" - 4" MODEL 350 FLOW RATES (I/s) 6.3 12.6 18.9 25.2 100 200 300 400 FLOW RATES (GPM) 25.2 50.4 6" (150mm) 8" (200mm) 400 800 1200 FLOW RATES (GPM) 63.0 1000 2000 FLOW RATES (GPM) 0 Rated Flow (Established by approval agencies) Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. FLOW CHARACTERISTICS 6" - 8" MODEL 350 FLOW RATES (Us) 75.6 10" - 12" MODEL 350 FLOW RATES (I/s) 126.0 31.5 500 100.8 1600 ONIELION Of Raw 4 37.8 600 189.0 3000 126.0 2000 44.1 700 151.2 2400 50 4 800 252.0 4000 WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805 /238 -7100 Fax:805/238 -5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905 /405 -8272 Fax:9051405 -1292 Product Support Help Line: 1- 877 - BACKFLOW (1 -877- 222 -5356) • Website: http: / /www.zurn.com 104 69 35 104 69 35 104 rs 69 to a. co co � Y W N O. 35 INDOOR INSTALLATION VERTICAL INSTALLATION (350GF) (350G) RECEIVE! DEC 12 2007 PERMIT CENT& SPECIFICATIONS The Double Check Backflow Prevention Assembly shall be ASSE® Listed 1015, and supplied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NORYLTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The checks shall be accessible for maintenance without removing the device from the line. The Double Check Backflow 'revention Assembly shall be a WILKINS Model 350. Page2of2 2 65mm) "(•Omm) -1/2" _ ) 4 100mm "( 0 15 n aN 10 CO co 0 5 a 0 0 0 0 TYPICAL INSTALLATION 2 -1/2" - 4" MODEL 350 FLOW RATES (I/s) 6.3 12.6 18.9 25.2 100 200 300 400 FLOW RATES (GPM) 25.2 50.4 6" (150mm) 8" (200mm) 400 800 1200 FLOW RATES (GPM) 63.0 1000 2000 FLOW RATES (GPM) 0 Rated Flow (Established by approval agencies) Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. FLOW CHARACTERISTICS 6" - 8" MODEL 350 FLOW RATES (Us) 75.6 10" - 12" MODEL 350 FLOW RATES (I/s) 126.0 31.5 500 100.8 1600 ONIELION Of Raw 4 37.8 600 189.0 3000 126.0 2000 44.1 700 151.2 2400 50 4 800 252.0 4000 WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805 /238 -7100 Fax:805/238 -5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905 /405 -8272 Fax:9051405 -1292 Product Support Help Line: 1- 877 - BACKFLOW (1 -877- 222 -5356) • Website: http: / /www.zurn.com 104 69 35 104 69 35 104 rs 69 to a. co co � Y W N O. 35 INDOOR INSTALLATION VERTICAL INSTALLATION (350GF) (350G) RECEIVE! DEC 12 2007 PERMIT CENT& SPECIFICATIONS The Double Check Backflow Prevention Assembly shall be ASSE® Listed 1015, and supplied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NORYLTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The checks shall be accessible for maintenance without removing the device from the line. The Double Check Backflow 'revention Assembly shall be a WILKINS Model 350. Page2of2 December 4, 2007 Dear Mr. Scott, City of Tukwila Department of Community Development Steve Lancaster, Director Jerry Scott MacDonald Miller Facility Solutions POBox47983 Seattle WA 98146 RE: CORRECTION LETTER #1 to REVISION #1 Plumbing/Gas Piping Application Number PG07 -090 Boeing # 9 -90 — 9725 East Marginal Way S This letter is to inform you of corrections that must be addressed before your plumbing permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Public Works Department. At this time the Building Department has no comments. Public Works Department: Joanna Spencer at 206 431 -2440 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted throufh the mail or by a messen,Qer service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, clAA'‘ Bill Rambo Permit Technician encl xc: File No. PG07 -090 P:\Pemiit Center\Correction Letters \20071PG07 -090 Corr Ltr #1 to Rev #1.DOC wet Steven M Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 PUBLIC WORKS DEPARTMENT COMMENTS www.ci.tukwila.wa.us Development Guidelines and Design and Construction Standards DATE: December 3, 2007 PROJECT: Boeing #9 -90 9725 East Marginal Way S PERMIT NO: PG07 -090 REVIEW NO: 1 (Revision #1 After Permit Issued) PLAN REVIEWER: Contact Joanna Spencer (206) 431 -2440 if you have any questions regarding the following comments. Please submit cut sheets for proposed backflows, cirle the devise you plan to install and make sure subject backflows are WA State Department of Health approved devises. Backflow schedule (top line) in upper right of sheet M2B calls for RPPA to be WILKINS 37T. It appears 37T is a typo, since Wilkins does not produce 37Ts. P: Joanna/Comments 1 PG07 -090 ACTIVITY NUMBER: PG07 -090 DATE: 12 -12 -07 PROJECT NAME: BOEING #9 -90 SITE ADDRESS: 9725 EAST MARGINAL WAY S Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 X Revision # 1 After Permit Issued DEPARTMENTS: Building Division P c� G (2� 01 ublig W .�CIVI J([� Comments: TUES/THURS RQUTING: Please Route Documents/routing slip.doc 2 -28-02 `PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Planning Division ❑ Permit Coordinator X TERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12-13-07 Complete I Incomplete ❑ Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01 -10 -08 Approved 0 Approved with Conditions Not Approved (attach comments) I i Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: PG07 -090 DATE: 11 -19 -07 PROJECT NAME: BOEING #9 -90 SITE ADDRESS: 9725 EAST MARGINAL WY S Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPARTMENTS 01 : i (. in g ivision Public Works r 111 Structural S NI/1 CA "CI [D ETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Incomplete ❑ TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ Planning Division ❑ Permit Coordinator ❑ DUE DATE: 11-20-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 2-18-07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) TVI Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only r, CORRECTION LETTER MAILED: 1 4 J7 Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW' Staff Initials: ACTIVITY NUMBER: PG07 -090 DATE: 04 -09 -07 PROJECT NAME: BOEING #9 -90 SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Bu I • J g Division inj h ilk- 4 Public Works. Complete Comments: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 ,., PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DATE: Planning Division n ❑ Permit Coordinator n DUE DATE: 04-10 -07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required ❑ No further Review Required n DUE DATE: 05-08-07 Not Approved (attach comments) F7 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 111t6D1 0C'he M ( 13 q - - a Summary of Revision: /pp p ,) uctAtfleg W p64.16. Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 111t6D1 0C'he M ( 13 q - - a Summary of Revision: /pp p ,) uctAtfleg W p64.16. Summary of Revision: - Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 111t6D1 0C'he M ( 13 q - - a Summary of Revision: /pp p ,) uctAtfleg W p64.16. Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF I TILLS , ..■*..-- 1 111t6D1 0C'he M ( 13 q - - a Summary of Revision: /pp p ,) uctAtfleg W p64.16. • CI) v-nu,cE Vi • (A) 1712(!(F C Received by: Je ' �c.G REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: PROJECT NAME: SITE ADDRESS: REVISION LOG PERMIT NO: � ry -f- DPI, C� ORIGINAL ISSIM DATE: o[ ?.', 67a- ease print ease print please print ease print ease print Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 12 1 2- 07 \applications\fomis- applications on line\revision submittal Created: 8 -13 -2004 Revised: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Plan Check/Permit Number: PG07 -090 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 • Revision # 1 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Boeing # 9 -90 Project Address: 9725 East Marginal Way S Contact Person: Jerry Scott Phone Number: (26 � ��� — ?Sy7 Summary of Revision: ( rl i SH e,f Fob &wi i IC_ C.) AT gie.. /v0 t ieg [C IOW Auk rok) Pie EVonrrt o n/ ,D1' ✓t < i S /17-- TA c J K1 Q1) :se t (7 � J 1 -)1 PFPM1Y flOrrEG Sheet Number(s): "Cloud" or highlight all areas of revision including date of revisi Received at the City of Tukwila Permit Center by: Entered in Permits Plus on Steven M Mullet, Mayor Steve Lancaster, Director RECFNFf CITY OF TUKWILA IDEC 12200/1 1 REVISION SUBMITTAL 1 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: I di, /6 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # L'Zpya-,TcO • Revision # 1 after Permit is Issued NQI/ q ❑ Revision requested by a City Building Inspector or Plans Examiner N� . 9 ?O4j y /T QENT ‘eaorl Project Name: RbaEttl) (al Project Address: C] 7 2s 45T / A,2&!NAL p Contact Person: JE le 0-1 S Con Phone Number: ( ZO6 — 76 — Z c ,+ Summary of Revision: Atu0 C 3) U gp_r 1 C TO 0,ilisTnA/C1 PEe rct IT ; - (z) 2 - c rc PPr“ve - 7 - ‘a : Db.utr%STt L t,JAr s�>v s>- te twig __" - ((') )003/.0 0-fgoic Ty PC Foe. PaocCss 1.✓A-TF4 r•I lai 3 1I?_1 tor)) j9ZS 1Mi-1S2 114714-1 1✓tq.--SE 1, EXE. SHOwN /)irmt- SjT P 4t1 1 Uv DO M71 St—to—ti uP ot) 7 H isSuE0 Peen -t,T Sheet Number(s): /AZ 1 3 ) MgSZ $151 ttk 314 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by Entered in Permits Plus on l I t \applications \forms- applications on Iine\revision submittal Created: 8 -13 -2004 Revised: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Plan Check/Permit Number: P (°Z C Y - 090 Steven M. Mullet, Mayor Steve Lancaster, Director Kind of Fixture Fixture Units No of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 2. 4 -'1 Dishwasher 2 2 Drinking fountain (each head) 1 .5 — z. — 1 Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 -70 -- 7 () Sink, Clinic flushing 8 8 Sink, kitchen 3 2 3 b Sink, other (service) 3 1.5 'Z 3 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 -...1r - / ( Urinal, flush valve, >1 GPF 6 2 Urinal, waterless 0 0 Water closet, tank or valve, 1.6 GPF 6 3 ;1.4' V' (1 Water closet, tank or valve, >1.6 GPF 8 4 -t 1 - 1 Non - Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type E M ay gl I n c:di Let_ S Property Street Address 1/ c� IS1et ty State ZIP Sohn Owner's Name Subdivision Name Subdiv. # Building Name _d_C). - o.z t'et C-0 vv■ r1,4 Owner's Phone Number (with Area Code) S-0--4- (Att c c 1 .d smart %SG 9 - q(7 (if applicable) (Z ` 1 13 - 04,44 Lot # Block # ( 2_0 ) '5 10 - y3 Property Contact Phone Number (with Area Code) Owner's Mailing Address ?D. 3 n-i(, 3 c7 rv\/ C 9 - ! 4 5-t� , �. °► 8 1 2 y A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Total F'xture Units - Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units 20 —11.1 Signature of Owner /Representa Print Name of Owner /Representative 1058 (Rev. 11/05) RCE � 1e 2c.. to White - King County King County Department of Natural Resources and Parks For King County Use Only Account # Monthly Rate 6 Month Rate Property Tax ID # 000 3 `lb- 60/ g Party to be Billed (if different from owner) City or Sewer District Date of Connection Side Sewer Permit # Demolition of pre- existing building? 0 Yes 0 No Type of building demolished Sewer disconnect date B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: p/A Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) = 187 C. Total Residential Customer Equivalents: (add A & B) A B 11. tzo RCE RCE RECD CITY OF TUKWILA i 9 0 2'.' i ° , VfJt PERMIT CENTER Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. The charge is collected semi- annually. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206 - 684 -1740. I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for deter ration of a revised capacity charge. Yellow - Local Sewer Agency Date (. 1- 1) -7 Pink - Sewer Customer DI-y-010 Boeing 9 -90 Waste Fixture Units 5- Apr -07 Coffman Engineers, Inc. Existing FU Removed Removed Fixture Demolished Each FU New FU Each FU bath /shower 0 4 0 0 4 0 Shower per head 0 2 0 2 2 4 dishwasher 0 2 0 0 2 0 drinking fountain each head 10 0.5 5 8 0.5 4 hose bibb interior 2 2.5 5 2 2.5 5 closthes washer/laundry tub 0 2 0 0 2 0 sink bar or lavatory 97 1 97 26 1 26 sink, Clinic flushing 0 8 0 0 8 0 sink, kitchen 3 2 6 6 2 12 sink, other Janitors 2 2 4 4 2 8 sink washfountain circle spray 0 3 0 0 3 0 urinal flush valve 20 2 40 12 2 24 urinal flush valve > 1 gpf 2 0 2 0 water closet tank or valve 1.6 gpm 3 0 28 3 84 water closet tank or valve >1.6 61 4 244 4 0 Totals Existing removed fixture FU count 401 New fixture unit count 167 Net reduction in FU's 234 401 167 • Parcel 000340 -0018 Present Use Industrial(Heavy) Name BOEING COMPANY THE Zoning MIC/H Site Address 9905 EAST MARGINAL WAY S 98108 Jurisdiction TUKWILA Geo Area 35 -65 Spec Area 625 -10 Property Type Code C Block Lot Legal Description GROW TIMOTHY -D C # 44 & 48 POR OF DC & DUWAMISH RIVER AS ESTAB BY CWW # 1 & SLIP # 7 & VAC CO RD & VACS 98TH ST DAF BEG 2222.8 FT W & 654.72 FT N OF SE COR OF DC TH S TAP 379.11 FT N OF S LN OF DC EXT W TH E TO E MGN VAC CO RD #57 TH S 89 -54-40 E 298.36 FT TH N 73 FT TH S 89 -54 -40 E 397.60 FT TO WLY MGN E MARGINAL WAY TH NWLY ALG SD MGN TO C/L VAC S 98TH ST TH SWLY & WLY ALG SD C/L TO ELY LN SLIP #7 TH N 13 -58 -30 W TO NLY LN SD SLIP TH WLY ALG SD NLY LN TO ELY LN CWW #1 TH SLY ALG SD ELY LN TAP N 89 -08 -00 W OF BEG TH S 89 -08 -00 E 1352.06 FT M/L TO BEG & POR BEG 2222.8 FT W & 654.72 FT N OF SE COR OF DC TH S TO MDR LN OF DUWAMISH RIVER TH N 74 -29 -52 W 466.63 FT TH S 70 -07 -00 W 489.88 FT TH N 43 -00-00 W 299.88 FT TH N 29- 00-00 W 562.76 FT TH S 89 -11-40 E TO BEG LESS PSH #1 Gross Sq Ft 1,893,084 %Ill.- Parcel 000340 -0018 BOEING COMPANY THE Parcel Data Land Data Land SqFt 2,265,120 Use Exemption Acres 52.00 Environmental No Water WATER DISTRICT Topography No Sewer /Septic PUBLIC Traffic No Views Rainier No Sound No Olympics No Lk Wash No Cascades No Lk Samm No Territorial No Lk/Riv /Crk No Seattle No Other No Waterfront Location DUWAMISH Footage 0 Bank No Access Rights No Tide/Shore No Prox. Influence No Restricted No Poor Quality No Building / Improvement Net Sq Ft 1,893,084 Building Nbr I) MANUFACTURING (BLDG 9 -101) Gross Sq Ft 1,112,432 Year Built 1957 Net Sq Ft 1,112,432 Effective Yr 1960 Construction PREFAB STEEL Page 1 of 4 License Information License MACDOFS980RU Licensee Name MACDONALD/MILLER FAC SOL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602254260 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 PO BOX 47983 Address 2 City SEATTLE County KING State WA Zip 98106 Phone 2067684180 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/31/2002 Expiration Date 12/31/2008 Suspend Date Separation Date Parent Company Previous License DIVCOI'988RC Next License Associated License Business Owner Information Name Role Effective Date Expiration Date SIGMUND, FREDRIC PRESIDENT 12/31/2002 KOPET, TYLER SECRETARY 12/31/2002 KOPET, TYLER TREASURER 12/31/2002 LOVELY, STEVE C VICE PRESIDENT 12/31/2002 Look Up a Contractor, Electri"ian or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= MACDOFS980RU 05/24/2007 COMPUTER ROOM COOLING UNIT (AC) SCHEDULE MARK NUMBER LOCATION (ROOM NUMBER) MAKE MODEL NOMINAL CAPACITY TONS FAN FAN MOTOR COIL COOLING CAPACITY CHILLED WATER AIR FILTER ELECTRICAL REMARKS TYPE & DEPTH EFFICI PER AS 52 -76 FINAL M AX NAL SP WG VOLTS PHASE FLA WSA MFCB DRIVE TYPE CAPACITY (CFM) ESP IN WG HP CAPACITY 1000 BTU /HR ROOM TEMP ('F) FLOW GPM EWT T MAX PD @ MAX FLOW FT H2O SENSIBLE TOTAL DB AC1K8 DCN RM 11J7 LIEBERT MINI -MATE2 MMD92C 5 DIRECT 2500 0.5 1.5 59,000 67,100 75 10 45 7.6 2 30% -- 208 3 2.8 3.5 15 FACTORY FILTER BOX, FILTER CLOG SWITCH, 2 WAY VALVE, CONDENSATE PUMP, AUXILIARY DRAIN PAN, LIQUI -TECT LEAK DETECTOR LT460 -Z20 W/ A 6' LONG WIRE TO UNIT, SMOKE DETECTOR, DISCONNECT AC1K7 ELEV EQ 13J6 LIEBERT MINI -MATE2 MMD23C 1.5 DIRECT 750 0.3 0.2 14,900 15,700 75 3.1 45 4.2 2 30% - 208 3 1 4 1 8 - FACTORY FILTER BOX, FILTER CLOG SWITCH, 2 WAY VALVE, CONDENSATE PUMP, AUXILIARY DRAIN PAN, LIQUI -TECT LEAK DETECTOR LT460 -Z20 W/ A 6' LONG WIRE TO UNIT, SMOKE DETECTOR, DISCONNECT AC1 E10 SoSAC SERVER LIEBERT SYSTEM 3 FH3O2C 15 BELT 9,300 0.35 (2) 5 185,200 206,200 75 4-5.0 45 11.9 4 60% - 208 3 98.8 123.5 125 (2) 5 HP FAN MOTORS, 2 WAY VALVE, 28.9 CV, DOWN FLOW MODEL WITH 12" HIGH SEISMIC ZONE 4 FLOOR STAND W/ BRACING FOR CONTRACTOR PROVIDED TURNING VANES, 34" FACTORY RETURN PLENUM W/O GRILLE, CONDENSATE PUMP, INFRARED HUMIDIFIER, ELECTRIC HEAT 81.0 MBH, LIQUI -TECT WATER DETECTION, HIGH EFFICIENCY FILTERS, SMOKE DETECTOR, DISCONNECT AC1E9 SoSAC SERVER LIEBERT "XD" SYSTEM XDP 46 - - - - 546,080 - - 140 45 41 - - - 208 3 4.0 - -- SPLIT SYSTEM, CONDENSATE DETECTION, XD PIPING SYSTEM & VALVES AC1E9a SoSAC SERVER LIEBERT "XD" SYSTEM (2) XDO 5.7 - - - - - - - - - - - - - 120 1 2.7 ea. - - EXTERNAL MOUNTING BRACKET, (3) BYPASS FLOW CONTROL VALVES, CONDENSATE DETECTION, (5 FUTURE) AC1 F10 SoSAS SERVER LIEBERT SYSTEM 3 FH302C 15 BELT 9,300 0.35 (2) 5 185,200 206,200 75 45.0 45 11.9 4 60% - 208 3 98.8 123.5 125 (2) 5 HP FAN MOTORS, 2 WAY VALVE, 28.9 CV, DOWN FLOW MODEL WITH 12" HIGH SEISMIC ZONE 4 FLOOR STAND W/ BRACING FOR. CONTRACTOR PROVIDED TURNING VANES, 34" FACTORY RETURN PLENUM W/0 GRILLE, CONDENSATE PUMP, INFRARED HUMIDIFIER, ELECTRIC HEAT 81.0 MBH, LIQUI -TECT WATER DETECTION, HIGH EFFICIENCY FILTERS, SMOKE DETECTOR, DISCONNECT AC1F9 SoSAS SERVER LIEBERT "XD" SYSTEM XDP 46 - - - - 546,080 - - 140 45 41 -- -- - 208 3 4.0 - - SPLIT SYSTEM, CONDENSATE DETECTION, XD PIPING SYSTEM & VALVES AC1 F9a SoSAS SERVER LIEBERT "XD" SYSTEM (5) XDO 5.7 - - - -- - - - - - -- -- - - 120 1 2.7 ea. -- - EXTERNAL MOUNTING BRACKET, (2) BYPASS FLOW CONTROL VALVES, CONDENSATE DETECTION, (3 FUTURE) AC1H7 SoSAU SERVERS LIEBERT SYSTEM 3 UH248C 12.5 BELT 5,900 0.3 3 149,700 190,000 75 37.6 45 19.1 4 60% - 208 3 65.5 81.9 90 (1) 3 HP FAN MOTOR, 2 WAY VALVE, 28.9 CV, UP -FLOW MODEL WITH FACTORY DISCHARGE PLENUM, CONDENSATE PUMP, INFRARED HUMIDIFIER, ELECTRIC HEAT 58.8 MBH, LIQUI -TECT WATER .DETECTION, HIGH EFFICIENCY FILTERS, SMOKE DETECTOR, DISCONNECT AC1D12 SoSAC BLUE TEAM LIEBERT DATAMATE DME044C -PC 3 DIRECT 1320 0.3 .27 24800 26900 75 7.5 45 10.4 2 - - 208 1 2.2 2.8 15 2 WAY VALVE, CONDENSATE PUMP, LIQUI-TECT WATER DETECTION SENSOR RECEIVED CITY OF TUKWILA 2 WAY VALVE, CONDENSATE PUMP, LIQUI -TECT WATER DETECTION SENSOR NOV 1 9 Z007 AC1E12 SoSAC BLUE TEAM LIEBERT DATAMATE DME044C -PC 3 DIRECT 1320 0.3 .27 24800 26900 75 7.5 45 10.4 2 - - 208 1 2.2 2.8 15 AC1F12 SoSAC RED TEAM . LIEBERT DATAMATE DMEO44C -PC 3 DIRECT 1320 0.3 .27 24800 26900 75 7.5 45 10.4 . 2 - - 208 1 2.2 2.8 15 2 WAY VALVE, CONDENSATE PUMP, LIQUI - TECT WATER DETECTION SENSOR PERMIT CENTER Poi t !I 1 k1 kI I II 1 AC1K9 SoSAS BLUE TEAM LIEBERT DATAMATE DMEO44C -PC 3 DIRECT 1320 0.3 .27 24800 26900 75 7.5 45 10.4 2 -- - 208 1 2.2 2.8 15 2 WAY VALVE, CONDENSATE PUMP, LIQUI -TECT WATER DETECTION SENSOR 1U1\1 AC1 K1 O SoSAS RED TEAM LIEBERT DATAMATE DMEO44C -PC 3 DIRECT 1320 0.3 .27 24800 26900 75 7.5 45 10.4 2 - - 208 1 2.2 2.8 15 2 WAY VALVE, CONDENSATE PUMP, LIQUI -TECT WATER DETECTION SENSOR AC2J7 DNC RM 21J6 LIEBERT MINI - -MATE2 MMD40C 3 DIRECT 1250 0.3 0.5 27305 30085 75 6 45 5.7 2 30% - 208 3 2.8 3.5 15 FACTORY FILTER BOX, FILTER CLOG SWITCH, 2 WAY VALVE, CONDENSATE PUMP, AUXILIARY DRAIN PAN, LIQUI -TECT LEAK DETECTOR LT460 -Z20 W/ A 6' LONG WIRE TO UNIT, SMOKE DETECTOR, c'g( -D PLU v BING FIXTURE SCHEDULE MARK NUMBER DESCRIPTION CONNECTION (INCHES) TYPE REMARKS BASIS OF DESIGN SAN VENT HW CW FIXTURE FAUCET /FLUSH VALVE (MIXING VALVE) SPOUT OR ACCESSORY DRAIN TYPE P -1 WATER CLOSET 4 2 - 1-1/4 WALL -HUNG (H) HANDICAP KOHLER KINGSTON K -4330 SLOAN OPTIMA ROYAL NO. 111 ES SEAT: OLSONITE 9555C HZ P -2 URINAL 2 1 -1/2 - 3/4 WALL -HUNG FLUSH VALVE (H) HANDICAP KOHLER BARDON K -4960 ET SLOAN SP-- S186- 10.ES -S -BOE W /EL 518 A-BOE BRONZE 50 P -3 LAVATORY 1-1/2 1 -1 /2 1/2 1/2 COUNTERTOP ELEC. SENSOR (120V TO COMMON TRANSFORMER) KOHLER INVITATION K -2098 SLOAN ETF -600 TRANSFORMER ELF- 154(ONE PER 3 LAVATORIES) START /STOP AS PROGRAMMED BY BUILDING DDC SYSTEM PUUGW6A P -4 LAVATORY 1-1/2 1-1/2 1/2 1/2 WALL HUNG DEDICATED TRANSFORMER KOHLER CHESAPEAKE K -1728 (4 "CENTERS) SLOAN ETF -600 TRANSFORMER ELF -154 - - P -5 SHOWER 2 1-1/2 1 /2 1 /2 G STALL W/ GRAB ELCOAT BARS &SEAT SET STALL, ON FULL BED GROUT STALL: LASCO 1603 BFSC COLOR: BONE CHICAGO 17621 S BRASS BODY W/ STAINLESS STEEL GRID P -6 ELECTRIC WATER COOLER 1-1/2 1-1/2 - 1/2 WALL HUNG PROVIDE WATER FILTER 4.5 AMP AT 120V -1 PH ELKAY EROM28RAC FILTER: EVERPURE 9-1/2" H54 SERIES W /QL -3 HEAD P -7 SINK 2 1 -1 /2 1 /2 1 /2 SINGLE COMPARTMENT COUNTERTOP, STAINLESS STEEL UNDER MOUNTED -REFER TO L ARCH FOR COUNTER DETAILS ELKAY ELU -1616 CHICAGO 201 AHA -8 GRID P -8 SERVICE SINK 3 2 1/2 1/2 FLOOR MOUNTED KOHLER WHITBY 6710 W /GUARD CHICAGO 956R -369 FD -1 FLOOR DRAIN VARIES VARIES - - 1 /2 "TRAP PRIMER (SAN ONLY) SEE PLAN FOR SIZE Zurn ZN-415-S STRAINER: ROUND NICKLE- BRONZE FD -2 FLOOR DRAIN VARIES VARIES - --- 1/2"TRAP PRIMER SEE PLAN FOR SIZE ZURN Z539 -G FFD -1 FLOOR DRAIN VARIES VARIES - - 1/2 "TRAP PRIMER SEE PLAN FOR SIZE ZN- 415 -8B W/ ZN -329 FS -1 FLOOR SINK 4" 2" - - 1/2 "TRAP PRIMER SERVER ROOM ZN-1900-2 PUMP (PU) SCHEDULE MARK NUMBER SERVICE FLUID TEMP 'F CAPACITY SIZE (IN) CONSTRUCTION PERFORMANCE MOTOR PUMP TYPE BASIS OF DESIGN SERVICE DATE REMARKS GPM TDH SUCT DISCH BODY FITTINGS EFF % NPSHR � DRIVE TYPE HP VOLTS PH HZ RPM PUPIG5A DOMESTIC HOT WATER RECIRC WATER 120 5.0 25 1 1 BRONZE BRONZE 50 - DIRECT 0.25 115 1 60 1750 INLINE BELL & GOSSEff SERIES 60 START /STOP AS PROGRAMMED BY BUILDING DDC SYSTEM PUUGW6A SUMP PUMP WATER - 35 15 - 1 -1/4 - - - - - 0.33 115 1 60 1800 SUBMERSIBLE PACO ASA SELF CONTAINED START /STOP SEMI - INSTANTANEOUS WATER HEATER SCHEDULE TAG SERVES LOCATION MWP (PSIG) CAPACITY (GPM) INLET TEMP °F OUTLET TEMP T CONNECTIONS (IN.) STEAM COND. PSIG UNIT POWER REQUIREMENTS UNIT WEIGHT FULL (LBS) BASIS OF DESIGN SERVICE DATE REMARKS CW � HW LB /HR PSIG VOLTS PHASE AMPS WHP1 G5A DOMESTIC PENTHOUSE 150 @300'F 18 40 120 1.25 1.25 720 15 2 115 1 2 PATTERSON -KELLY PK 06D DOUBLE WALL HEAT EXCHANGER PROVIDE W/ F&T TRAP. ASME (SECTION 8) VESSEL BACKFLOW PREVENTER SCHEDULE MARK NUMBER SERVICE DEVICE SIZE (INCHES) TYPE CAPACITY BASIS OF DESIGN GPM PD (PSI) BF1 D71A DOMESTIC WATER SERVICE 3 REDUCED PRESSURE 200 13 WILKINS 37,5 ; BF1 D71B DOMESTIC WATER SERVICE 1-1/2 REDUCED PRESSURE 100 15 WILKINS 975 I BF1 V61A IRRIGATION WATER 2 -1/2 DOUBLE CHECK 100 6 WILKINS 350 MFCB - WSA - FLA - MAXIMUM FUSE OR CIRCUIT BREAKER WIRE SIZING AMPS FULL LOAD AMPS DOE /A/6 EXPIRES 1/10/09 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN CHECKED M.SOTURA ENGINEER CHECKED APPROVED APPROVED DATE 01.15.07 01.15.07 SUBTITLE TITLE ISSUE FOR CONSTRUCTION MECHANICAL MASTER Plan review approval Is ${1g8dto erne end owns. Approval of construction documoi s dose not authorize the vin of any adopted code or ordnance. Receipt of approved Is acknowledged: City of Tukwila BUILDING DIVISION COFFMAN N G I N E E R S 1601 Fifth Avenue Suite .900 Seattle, Washington 98101 --1625 206 623 0717 Fax 206 624 3775 MECHANICAL SCHEDULES 9 -90 RENOVATION BUILDING 9 -90 T REVISIONS No ohn Opes Shnli he mad to the Seona i of work without prior approval of Ttekv+;iia Building Division. • °.'r •E. Re; =isions will require a new plan submittal ;;'ii may include additional plan revinw fees. 1 DEV. CENTER,WA CURRENT REVISION SHEET JOB NO. DWG NO. M26 150680 -01 b SYMBOL R I 0 09- 090 -M2B 1■1QV "0 "97 vvjRKS DATE COMP NO. SYM REVISION ORIG 9 -90 RENOVATION J #150680 -01 BY COFFMAN APPROVED DATE SYM M.SOTURA 04.26.07 REVISION BY APPROVED DATE 04.26.07 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE AnS/A ®"' , ra W Wr %i 1 , � r " " 0f ' . Q. 0 ACCEPTABILITY DESIGN SPECIFICATION IS AP DRAWN C DATE 01.15.07 SUBTITLE ENLARGED MECHANICAL ROOM PLANS CURRENT REVISION SYMBOL.O RIG ^ iGv DATE 04.26.07 ORIG 9-90 RENOVATION J#150680-01 COFFMAN M. SOTURA 04.26.07 C KED M.SOTURA 01.15.07 SHEEP 1M452 A PPROVED BY DEPT. DATE ENGINEER MECHANICAL MASTER 9--90 RENOVATION BUILDING 9-90.1 DEV. CENTER,WA CHECKED APPROVED JOB NO. 150680 -01 COMP N0. EXPIRES i /io /ag APPROVED DWG NO 09-090-1M452 SEE 1M110 & 1M260 FOR CONTINUATION OF PIPING 8 "F 6 "CW 3 "V DN EXISTING 8" 6" HUB DRAIN FIRE SPRINKLER (E) FLOOR DRAIN ALARM VALVE MECH. 1 -1 /2 "PRV OVER 3 "PRV, SEE 1/M313 3/4" 125# MPC 3 "V DN 1" 4 "W DN 1-1/4"C DN TO DRAIN 1ST FLOOR SCALE 7/2'= 1' -0" 1ST FLOOR SCALE: 7/2'= 1' -0" 1106 if D 7IB OVER D7IA SEE 1/M313 VECH •- 1106 n 1M3, 1M11, 1M61 1M452 2 -1/2" Y -TEE W /SHUT --OFF VALVE AND TH R' D CAP 14/14 SOUNDLINED TRANSER BOOT, SEE 1/M506 NECH - 12J6 (� 1M3, 1M11, 1M61 1M452 00000 14/12 EXHAUST DUCT 1" MPS 2---1 /2 "PW MECH. 11V6 } 3/4" 60# MPS TO PUMPS LADDER 2 -1 /2 "CW (E)3 "V UP 2-1/2" LANDSCAPE DOUBLE CHECK VALVE /BPIN V6 I A 3/4 "A DN TO PIT & CONDENSATE PUMP W /HOSE END VLAVE & DIRT LEG ± 36" ABOVE FLOOR 5" DUCT (20 GA.) DN TO 4' ABOVE PIT FLOOR LEVEL W /MESH SCREEN AT BOTTOM WITH 14"95 EXHAUST DUCT FROM SHAFT ABOVE 6" MPS UP TO 2ND FLOOR WITH NEW SHUTOFF VALVE AND 2" BY -PASS. SEE DETAIL 1/M508 CAP 6 "STEAM 125# MPS (BELOW SLAB) 3 "PUMPED CONDENSED (BELOW SLAB) -'j 1 "COMPRESSED AIR (ABANDONED BELOW SLAB) 3"MPC 3" "PUMPED CONDENSED 1ST FLOOR MECH - 11V6 SCALE: 1/2' = 1' -0" UGM3, 1M3, 1M13, 1 M63 1 M452 REPLACE SUMP PUMP 4" WASTE FROM MH #2 EL 6.25' SUv1P PUv1P SCALE: 1/2 ° = 1' -0" (E)6 "HUB DRAIN 16x16 CEILING MOUNTED 8 "F UP 8" AUTOMATIC WET FIRE SPRINKLER ALARM VALVE (EXIST) 3/4 "A UP WALL GRILLE 18X16 1 "MPS PP lA 3/4 "MPC SUMP PUMP, . SEE 4/1M452 PRV -3, SEE DETAIL 2/M509 PAN ( 1M452 1"STM VENT UP TO ROOF 3 "STM VENT UP TO ROOF 2 "CHECK VALVE 4# LEAD FLASHING 12" ALL AROUND SLEEVE J _ 4 "W 2 "W (GALV PIPE) IN ZURN Z- 195 --3 FLASHING SLEEVE {D ISSUE FOR CONSTRUCTION A COFFMAN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 LEGEND A C CW - - -CW F -- F - - LPC MPC - MPS PC PW V W 1 ?'101--o°10 t COMPRESSED AIR. PLANT CONDENSATE RETURN (GRAVITY) DOMESTIC COLD WATER DOMESTIC COLD WATER BELOW GRADE FIRE LINE FIRE LINE, BELOW GRADE OR FLOOR LOW PRESSURE CONDENSATE MEDIUM PRESSURE CONDENSATE MEDIUM PRESSURE STEAM CONDENSATE RETURN (PUMPED) PROCESS WATER VENT WASTE WASTE BELOW GRADE 0 VENT THROUGH ROOF ot— PIPE ELBOW, TURNED UP OR TOWARD c - t - PIPE ELBOW TURNED DOWN OR AWAY POINT OF CONNECTION RETURN OR EXHAUST AIR FLOW DIRECTION STEAM TRAP Q- BALL VALVE WITH HOSE END r- VD (VOLUME DAMPER) GENERAL VOTES 7 STEAM CONDENSATE EQUIPMENT IS IN A 7' DEEP PIT. PIT IS 67 "x73" WITH A FLOOR GRILLE ON TOP. REFEREN CE DRAWMS UGM3, COMPOSITE UNDERGROUND PLUMBING PLAN 1M3, COMPOSITE FIRST FLOOR PLUMBING PLAN M314, PLUMBING DIAGRAMS 1M61, FIRST FLOOR HVAC PIPING PLAN 1M63, FIRST FLOOR HVAC PIPING PLAN CONSTRUCTICk REPLACE FLOW AND TAMPER SWITCHES. CONTRACTOR SHALL INSTALL SWITCHES PROVIDED BY "ADT ". PROVIDE A SHUTOFF VALVE WITH BYPASS FOR THE 6 "MPS RISER. PROVIDE NEW 2-1/2" PUMPED CONDENSATE. NOT USED PROVIDE STEAM CONDENSATE PUMP PACKAGE PROVIDE NEW 2" CHECK VALVE PROVIDE 1" 60 PSI STEAM PROVIDE STEAM VENT PROVIDE TEMPORARY CONNECTION TO SANITARY SEWER UNTIL WASTE CONNECTION IS COMPLETE, SEE UGM3. 1 INSTALL VD BETWEEN GRILLE AND 5" DUCT © O1 0 0 0 0 OTES RECEIVED CITY OF TUKWILA NOV 19 200 PERMIT CENTER u a c 1- w Z 0 SYM ()RIG 1/2" -r = "COFFEE SINK MAKER J P -7 WATER FILTER (TYP) 6" PENTHOUSE 9 -90 RENOVATION SECOND FLOOR FIRST FLOOR 1 REVISION 3/4 "-- ) 8 TRAP PRIMER (ACCESSIBLE FROM PENTHOUSE FLOOR) TYPICAL It~ N TO FD'S, DRIP INTO DRAINS DRIP INTO FD W /2" AIR GAP - HWC J #150680 -01 120V POWER SUPPLY, HW �~ SEE ELECTRICAL 111.-HW 1 1 1 BY 0 71 1 -1 /2 "RPBA / d ► COFFMAN TP 1 -1/2 "PRV 65PSI DISCHARGE TP _- P-5 BF1 3 "RPBA 3" 1; 71 Y L WITH DRAIN LINE TO FLOOR DRAIN 1 - 1/4 P -5 TRANSFORMER ACCESSIBLE ABOVE CEILING v❑ 1 III*r G 1+ I]4 2" APPROVED M. SOTURA 4Y 2-1/2" -�-� 3 I):( 11 3 "PRV. 60PSI DISCHARGE C 1 I I 3" 3" 3/4" 3/4" C 1 /2" HOSE END BALL VALVE HWC I I 1 11 REVISION 3/4" P -7 SINK ,) j ( /'' 1; -. 1 1- 01 ?-1 /2" LAV 1 CI- I X1 ± 1 -e, N I COFFEE MAKER 1 LAV P -3 P -3 120V POWER SUPPLY, SEE ELECTRICAL POWER SHUT -OFF SWITCH, PROVIDE LABEL "TOILET ROOM WATER SHUT -OFF SWITCH FOR CLEANING ". I�-HW P -8 Z+ 4— SCALE: NONE EXPANSION TANK CAPACITY TOTAL VOLUME 6.4 GAL. ACCEPT VOLUME 3.2 GAL. ELEVATE FOR FREE DRAINAGE OF CONDENSATE HOUSEKEEPING PAD PER STRUCTURAL LAV P -3 T BY C CWT -eh 3/4" � r I 3/4" p 2-1/2" LPS 5 + I LPS N) t p I 1" �_ 2-- 1/2 "--� 1 ; 1 1 1 1 1 1 11 FAUCET VALVE Et- 11- C 2" HW 2-1/2" --�� CW 1 1 + =_ 3/4" LAV LAV REMOTE TRANSFORMER FOR SENSOR FAUCETS /FLUSH VALVES � 1-2- LOCKING • HANDLE T THERMOSTATIC MIXING VALVE (TYPICAL) • WEST CORE PLUMBING RISER APPROVED DATE HIGH TEMP. RELIEF VALVE ❑ TO FFD T TO FFD n 1 -1/4" J HW LOW VOLTAGE WIRING TO SENSOR CONTROLLERS 3" CONTROL PANEL 1 IcF l WC WC WC WC URN WC URN WC URN WC P -1 P -1 P-1 P -1 P -2 P -1 P -2 P -1 P-2 P-1 2 -1/2 _1 II II I I I CW t 1 1 1M450, 2M450 M313 1-TP" s-Tp� T & P RELIEF 1 HW • F &T TRAP ACCESS DOOR WC WC WC WC WC URN WC URN WC URN P -1 P -1 P--1 P -1 P -1 P -2 P -1 P -2 P-1 P -2 EXPIRES 1/10/09 1/2" P -3 WATER FILTER TRAP PRIMER SLEEVE (TYP) WATER HAMMER ARRESTOR. LOCATE ACCESSIBLE ABOVE CEILING (TYPICAL) SIZE PER PDI STANDARDS SENSOR (TYPICAL) I}1 0 LAV 2" LAV 13- C LAV WATER FILTER LAV FAUCET CONTROLLER (TYP) ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE P -3 P-3 LAV LAV DRAWN COFFMAN CHECKED M.SOTURA ENGINEER CHECKED APPROVED APPROVED DATE 01.15.07 01.15.07 COFFEE SINK MAKER 1 L.1 P -7 TITLE n e, ISSUE FOR CONSTRUCTION SUBTITLE MECHANICAL MASTER HWC 3 HW 1 -1/4" C FOR CONTINUATION SEE M314 FOR CONTINUATION SEE M314 ACOFFMAN N G 1 N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 PLUMBING DIAGRAM 9-90 RENOVATION BUILDING 9 -90 LEGE GEC DEV. CENTER WA CW HW HWC I0I I%l FD ESJ \D ERAL REFEREI\ CONSTRUCTIO vto CURRENT REVISION SHEET JOB ND. 150680 -01 DWG N0. DOMESTIC COLD WATER DOMESTIC HOT WATER SUPPLY DOMESTIC HOT WATER CIRCULATING BALL VALVE SOLENOID OPERATED VALVE CHECK VALVE WITH FLOW BUTTERFLY VALVE TRAP PRIMER FLOOR DRAIN AUTOMATIC FLOW CONTROL VALVE OTES CE DRAWI\CS M313 NOTES RECEIVED CITY OF TIJKWILA NOV 1 9 2007 PERMIT CENTER SYMBOLO R I G DATE 09- 090 -M313 COMP N0. 04.26.07 SYM ORIG 9 -90 RENOVATION REVISION FOR CONTINUATION SEE 2M3 & .M313 FOR CONTINUATION SEE 1M3 & M313 J #150680 --01 BY 1 /2" COFFMAN 3/4" APPROVED M. SOTURA HW E M LAV P -3 4 DATE SYM 04.26.07 P-3 TRAP PRIMER (ACCESSIBLE FROM PENTHOUSE FLOOR, TYP) DRIP INTO FD W /2" AIR GAP (TYP) P -3 HW � 1.�1 1 -1/4" 1/2" 2 -1/2" TRANSFORMER FOR SENSOR - T �_` FAUCET VALVES ABOVE CEILING, ACCESSIBLE 1/2" U z P-7 COFFEE SINK MAKER U P-8 -1- -1- 1/2" P -7 SINK — i — I cICW I 1 /2" V REVISION P POWER SHUT -OFF SWITCH, PROVIDE LABEL "TOILET ROOM WATER SHUT -OFF SWITCH FOR CLEANING ". REMOTE TRANSFORMER FOR SENSOR FAUCETS /FLUSH VALVES COFFEE MAKER 4 120V POWER SUPPLY, SEE ELECTRICAL CW V P -3 I.1 I P-8 - -1- TP 3/4" BY HW LAV P-3 APPROVED 1/2" P -3 HOSE END BALL VALVE 120V POWER SUPPLY, SEE ELECTRICAL i SCALE: NONE 1/2" LAV U U N 1 -1/4" CW DATE P -3 SLEEVE (TYP) EAST CORE PLUNBI WC 2 -1 /2 "� 1 1 1 1 1 I I 1 1 Cw 1 WC WC WC WC P -1 P-1 P -1 P -1 P-1 2-1/2" 1" .� -- -2 -1 /2 WC WC WC WC WC P -1 P -1 P-1 P -1 P -1 HW G RISER URN WC URN WC URN P -2 P -1 P-2 P -1 P -2 1-1/2" 2" AiratetfrAW URN WC URN WC -1/4" DF --� P -6 URN P -2 P -1 P -2 P -1 P -2 1 1M450, 2M4501914 `TP-1 c ■ . I 8 I LAV HW P -3 WATER HAMMER ARRESTOR. LOCATE ACCESSIBLE ABOVE CW 1 /2" , 1 CEILING (TYPICAL) SIZE PER 1-1/2" -- I PDI STANDARDS 2" t I 1/2" I � -- SENSOR (TYPICAL) B I LAV DF 1 P -6 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY LAV P -3 P -3 P -3 WATER FILTER (TYP) DEPT. LAV DATE P -3 P-3 LAV DRAWN COFFMAN CHECKED M.SOTURA TRGIREER CHECKED APPROVED APPROVED a 1 1/2" DATE 01.15.07 01.15.07 PENTHOUSE SECOND FLOOR --PW TO IRRIGATION SYSTEM, SEE PLANS SUBTITLE 2-1/2" DOUBLE CHECK VA FIRST F ISSUE FOR CONSTRUCTION MECHANICAL MASTER PLUMBING DIAGRAM 9 -90 RENOVATION BUILDING 9 -90 COFFMAN 61X EE 0.S N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 DEV. CENTER,W LEGEND CW HW HWC C0\ Icj I ly0 I74 GUAGE PIPE REDUCER GE \ERAL COTES REFERENCE DRAWINGS P STRUCTION CURRENT REVISION SHEET JOB NO. DWG NO. DOMESTIC COLD WATER DOMESTIC HOT WATER SUPPLY DOMESTIC HOT WATER CIRCULATING BALL VALVE, OPEN BALL VALVE, CLOSED SOLENOID OPERATED VALVE CHECK VALVE WITH FLOW BUTTERFLY VALVE, OPEN BUTTERFLY VALVE, CLOSED WYE STRAINER (W/ DRAIN VALVE) 2 WAY CONTROL VALVE GATE VALVE PRESSURE REDUCING VALVE PUMP AUTOMATIC FLOW CONTROL VALVE TRAP PRIMER HOSE BIBB M314 150680 -01 TES RECEIVED CITY OF TUKWILA NOV 1 9 2007 PERMIT CENTER SNe04 ORIG DATE 09- 090 --M314 COMP NO. 04.26.07 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ORIG 9 -90 RENOVATION J4150680 -01 DLR GROUP OR /LS 04.05.07 VICINITY MAP 99 7-127 KING COUNTY CENTER AIRPORT (FAA) e co Q 99 FROM SEATTLE— TACOMA AIRPORT FROM DOWNTOWN SEATTLE EAST MARGINAL WAY CORPORATE PARK [30 599 TUKWILA DEVELOPMENTAL CENTER 900 EXIT 157 EXIT 158 FROM KENT & AUBURN NCV • • EXIT 157 900 NO SCALE TAR" A BUILDI\ G G -90 RE\OVATIO\ (voLuv4E 2 OF 2) JOB X150680 -01 BOEING DEVELOPVENTAL CE \TER 9725 E. VARGI\AL WAY S. LKWILA, WASHI \GTO\ 98108 AREA MAP BUILDING ADDRESS: 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 9 -90 BUILDING LOCATION NO SCALE RCRAFT �C iSLAPPMFArAW v ss GENERAL NOTES DEMOLITION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING DEMOLITION. DO NOT PROCEED WITH DEMOLITION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO GARY TALLER AT BUILDING 9 -51.2 COLUMN N /1, AFTER COMPLETION OF WORK OF THIS CONTRACT. PROJECT CHECKLIST CHECK BOX 181 THESE DRAWINGS CONFORM TO THE I.B.C., I.F.C., LM.C., U.P.C., N.E.C. AND THE WAC 51--20 AS ADOPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CITY OF TUKWILA, WASHINGTON ZONING. ❑ ROOMS LABELED PER OCCUPANCY PER I.B.C. TABLE 1004.1.2. ® BUILDING FLOOR NUMBER ON PRINT. FOR AREA OF CONSTRUCTION. ® NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: ❑ 1. TENANT IMPROVEMENT (STRUCTURAL): ❑ 5 SETS OF ARCHITECTURAL DRAWINGS O 5 SETS OF STRUCTURAL DRAWINGS ❑ 5 SETS OF STANDARD DETAILS ❑ 5 SETS OF ENGINEERING CALCULATIONS ❑ 5 SETS OF ENERGY CALCULATIONS ❑ 5 SETS OF CONSTRUCTION SPECIFICATIONS ® 2. TENANT IMPROVEMENT (NON — STRUCTURAL): ❑ 4 SETS OF ARCHITECTURAL DRAWINGS O 4 SETS OF STANDARD DETAILS ❑ 4 SETS OF ENERGY CALCULATIONS O 4 SETS OF CONSTRUCTION SPECIFICATIONS ❑ 3, MECHANICAL, 4 COMPLETE SETS. ❑ 4. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS. BRIEF PROJECT NARRATIVE: SELECTIVE DEMOLITION OF BOTH FLOORS OF THE 9 -90 BUILDING, WITH REMOVAL OF MOST INTERIOR WALLS, TOILET ROOMS, CEILINGS, FLOOR COVERINGS, EXTERIOR GLAZING SYSTEMS, MECHANICAL HVAC & PLUMBING SYSTEMS AND ELECTRICAL POWER & LIGHTING THROUGHOUT. PROJECT ALSO INCLUDES INSTALLATION OF NEW WALLS, CEILINGS AND FLOOR COVERING THROUGHOUT. INSTALLATION OF NEW EXTERIOR WINDOW AND ENTRY SYSTEMS AND NEW MECHANICAL HVAC & PLUMBING SYSTEMS AND ELECTRICAL POWER AND LIGHTING SYSTEMS TO SUPPORT THE NEW LAYOUT. 5185 C ITE T 11 KRUSE STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DLR GROUP CHECKED ENGINEER CHECKED APPROVED APPROVED DATE 12.05.05 SUBTITLE SYST (Plan review approval Is subject to errors and omission Approval of construction documents does not author the violation of any accepted code or ordinance. Receipt d approved F 9 y and co :bons is acknowledged: BY Date: , 4/0 7 \ City of Tukwila BUILDING DIVISION CODE SU VIVIARY LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS FIRST FLOOR SECOND FLOOR PENTHOUSE BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC CATEGORY: DESIGN LOADS: ROOF — SNOW ROOF -- LIVE FLOOR -- OFFICE (LIVE) FLOOR' — DEAD FLOOR — MECHANICAL & STORAGE FLOOR -- STAIRS AND CORRIDORS WIND LOADING CITY OF TUKWILA, WASHINGTON * 2003 INTERNATIONAL BUILDING CODE (IBC) * 2003 INTERNATIONAL FIRE CODE (IFC) * 2003 INTERNATIONAL MECHANICAL CODE (IMC) * 2005 NATIONAL ELECTRICAL CODE (NEC) * 2005 UNIFORM PLUMBING CODE (UPC) * 2005 STATE OF WASHINGTON ENERGY CODE * STATE OF WASHINGTON BARRIER FREE CODE WITH ICC A117.1 * CITY OF TUKWILA, WA. AMENDMENTS GROUP 8, OFFICE TYPE II —B, NON—COMBUSTIBLE 67,351 145,382 67,351 67,351 10,680 44 F. 2 NO CHANGES „ 25 PSF 20 PSF 150 PSF 20 PSF (PARTITION) 125 PSF 150 PSF 80 MPH, EXPOSURE C BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT RECEIVED APR 1 O 2007 PUBLIC W RKS ISSUE FOR PER VII T TITLE SHEET - VOLUME 2 9 -90 RENOVATION BUILDING 9 -90 ARCHITECTURAL MASTER COL. vs DEV. CENTER, WA SHEET JOB DWG NO. 1 .S7_773AfIATE PEA �Iechanirai Clectrical 17 Plumbing C1 Gzrs Piping City of Tukwila BUILDING DIVISION No chartsPes shan b12134e I &eyi� NOT t " C a dodo ° ap / IA TI ED APR 0 9 2001 P£i r'�!T CEA( T () I L O � DLR Group CURRENT REVISION Architecture Engineering Planning interiors GO NO. 150680 -01 ect ORIG 09- 090 —GO DATE COMP NO. 04.05.07 GYM ORIG 4 9 -90 -G3 9 -90 -1M1OR 9-90 -1M11R 9 -90 -1M12R 9 -90 -1M13R 9-90 -1M6OR 9 -90 -1M61R 9 -90 -1M62R 9 -90 -1M63R 9 -90 -2M3R 9 -90 -2M4R 9 -90 -2M1OR 03 INDEX OF DRAWINGS -- VOLUME' 2 UGM3R 1M3R 1M4R COMPOSITE UNDERGROUND PLUMBING REMOVAL PLAN FIRST FLOOR PLUMBING REMOVAL PLAN FIRST FLOOR FIRE SPRINKLER REMOVAL PLAN 1M1OR FIRST FLOOR DUCTWORK REMOVAL PLAN 1M11R FIRST FLOOR DUCTWORK REMOVAL PLAN 1M12R FIRST FLOOR DUCTWORK REMOVAL PLAN 1M13R FIRST FLOOR DUCTWORK REMOVAL PLAN 1M6OR FIRST FLOOR HVAC PIPING REMOVAL PLAN 1M61R FIRST FLOOR HVAC PIPING REMOVAL PLAN 1M62R FIRST FLOOR HVAC PIPING REMOVAL PLAN 1M63R FIRST FLOOR HVAC PIPING REMOVAL PLAN 2M3R SECOND FLOOR PLUMBING REMOVAL PIIAN 2M4R SECOND FLOOR FIRE SPRINKLER REMOVAL PLAN 2M1OR SECOND FLOOR DUCTWORK REMOVAL PLAN 9 -90 -2M11R 9 -90 -2M12R 9---90 -2M13R 9 -90 -2M60R 9-90 -2M61R 9 -90 -2M62R 9--90 -2M63R 9- 90 -P1M3R 9 -90 -P1 M4R 9- 90- P1M450R 9- 90--P1 M451 R 9- 90-RFM3R 9 -90 -MO 9 -90 -M1 9 -90 -M2A 9 -90 -M2B 9- 90 --M2C 9 -90 -UGM3 9 -90 -1M110 2M11R SECOND FLOOR DUCTWORK REMOVAL ,PLAN . 2M12R SECOND FLOOR DUCTWORK REMOVAL .PLAN 2M13R SECOND FLOOR DUCTWORK REMOVAL PLAN 2M60R 2M61R 2M62R 2M63R P1 M 3R P1M4R P1M450R P1M451R RFM3R MO M1 M2A M2B M2C UGM3 1M110 SECOND FLOOR HVAC PIPING REMOVAL; PLAN SECOND FLOOR HVAC PIPING REMOVAL. PLAN SECOND FLOOR HVAC PIPING REMOVAL. PLAN SECOND FLOOR HVAC PIPING REMOVAL. PLAN PENTHOUSE PLUMBING REMOVAL PLANS PENTHOUSE FIRE SPRINKLER REMOVAL PLANS ENLARGED WEST PENTHOUSE HVAC REMOVAL PLAN ENLARGED EAST PENTHOUSE HVAC REMOVAL PLAN COMPOSITE ROOF MECHANICAL REMOVAL PLAN COORDINATION FIRST FLOOR PLAN COORDINATION SECOND FLOOR PLAN MECHANICAL SCHEDULES MECHANICAL SCHEDULES MECHANICAL SCHEDULES COMPOSITE UNDERGROUND PLUMBING RLAN FIRST FLOOR PLUMBING PLAN 1 9-90 -1M113 9-90 -2M110 9 -90 -2M111 9 -90 -2M112 9 -90 -2M113 1M113 FIRST FLOOR PLUMBING PLAN 2M110 SECOND FLOOR PLUMBING PLAN 2M111 SECOND FLOOR PLUMBING PLAN] 2M112 SECOND FLOOR PLUMBING PLAN 1 2M113 SECOND FLOOR PLUMBING PLAN ' . 9 -90 -1M12 9 -90 -1M13 9 -90 -2M10 1M12 FIRST FLOOR DUCTWORK PLAN 1M13 FIRST FLOOR DUCTWORK PLAN 2M10 SECOND FLOOR DUCTWORK PLAN ORIG ORIO ►{ 9 -90 -UGM3R 0. 9 -90 -1M3R 9--90 -1M4R ❑: 9---90 -1M111 9 -90 -1M112 1M111 FIRST FLOOR PLUMBING PLAN 1M112 FIRST FLOOR PLUMBING PLAN 9 -90 -1M10 9 -90 -1M11 1 M1 O FIRST FLOOR DUCTWORK PLAN i 1M11 FIRST FLOOR DUCTWORK PLAN , 9 -90 -2M11 2M11 SECOND FLOOR DUCTWORK PLAN 9-90 -2M12 2M12 SECOND FLOOR DUCTWORK PLAN 9 -90 -2M13 9 -90 -1M6O 9 -90 -1M61 2M13 SECOND FLOOR DUCTWORK PLAN 1M60 FIRST FLOOR HVAC PIPING PLAN 1M61 FIRST FLOOR HVAC PIPING PLAN' 9 -90 -1M62 1M62 FIRST FLOOR HVAC PIPING PLAN REV ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG OR1G ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORI G ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG 9 -90 -1M63 9 -90 -2M60 9 -90 -2M61 9 -90 -2M62 9 -90 -2M63 9-90-1M260 1 M63 FIRST FLOOR HVAC PIPING PLAN 2M60 SECOND FLOOR HVAC PIPING PLAN 2M61 SECOND FLOOR HVAC PIPING PLAN 2M62 SECOND FLOOR HVAC PIPING PLAN 2M63 SECOND FLOOR HVAC PIPING PLAN 1M260 FIRST FLOOR FIRE SPRINKLER PLAN ' ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG INCLUDED IN SET 9 -90 RENOVATION DRAWING NO. 9 -90 -GO 0 9- 90 -1M261 9-90-1M262 • 9- 90 -1M263 REVISION SHEET NO GO J#150680 -01 DRAWING SUBTITLE MECHANICAL TITLE SHEET -- VOLUME 2 1M261 FIRST FLOOR FIRE SPRINKLER PLAN 1M262 FIRST FLOOR FIRE SPRINKLER PLAN 1M263 FIRST FLOOR FIRE SPRINKLER PI!AN BY DLR GROUP APPROVED DR /LS DATE 04.05.07 SYM ORIG DI- X OF DRAW DATE 04.05.07 04.05.07 04.05.07 04,05 07 04.05.07 04.05.07 04.05.07 04.05.07 04 05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04,05 07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04,05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 REVISION 1:3 0 • ❑ 0 9- 90 -2M261 9- 90 -2M262 9- 90 -2M263 9- 90- UGM450 9 -90-1 M450 9 -90 -1 M451 9- 90 -1M452 9- 90- -2M450 9- 90 -2M451 9- 90-- P1M450 9 -90 -P1 M451 9- 90- PIM452 9- 90- P1M453 9 -90 -P1 M454 9- 90- P1M455 9 -90 -RFM3 9-- 90 -M310 9- 90 -M311 9- 90 -M312 9- 90 -M313 9- 90 -M314 9-- 90 -M315 9- 90 -M500 9- 90 -M501 9- 90 -M502 9- 90 -M503 9- 90 -M504 9- 90 -M505 9- 90 -M506 9- 90 -M507 9- 90 -M508 9- 90 --M509 9- 90 -M510 9- 90 -M51OA 9-90-2E2R 9- 90 -1E7R 9 -90 -2E7R 9- 90 -1E1OR 9- 90 -1E11R 9- 90 -1E12R 9-90-1E1 3R 9- 90 -2E1OR 9- 90 -2E11 R 2M261 2M262 2M263 UGM450 ENLARGED UNDERGROUND DRAINAGE PLANS 1M450 ENLARGED TOILET ROOM DOMESTIC WATER PLANS 1M451 1 M452 2M450 2M451 P1M450 PAM451 P1 M452 P1 M453 P1 M454 P1M455 RFM3 SECOND FLOOR FIRE SPRINKLER PLAN SECOND FLOOR FIRE SPRINKLER PLAN SECOND FLOOR FIRE SPRINKLER PLAN ENLARGED TOILET ROOM DRAINAGE PLANS ENLARGED MECHANICAL ROOM PLANS ENLARGED TOILET ROOM DOMESTIC WATER PLANS ENLARGED TOILET ROOM DRAINAGE PLANS ENLARGED WEST PENTHOUSE HVAC PLAN ENLARGED EAST PENTHOUSE HVAC PLAN ENLARGED WEST PENTHOUSE PLUMBING PLAN ENLARGED EAST PENTHOUSE PLUMBING PLAN ENLARGED WEST PENTHOUSE FIRE SPRINKLER PLAN ENLARGED EAST PENTHOUSE FIRE SPRINKLER PLAN COMPOSITE ROOF MECHANICAL PLAN M310 CONTROLS DIAGRAM M311 SEQUENCE OF OPERATION M312 STEAM SYSTEM DIAGRAM M313 PLUMBING DIAGRAM M314 PLUMBING DIAGRAM M315 _ COMPRESSED AIR AND FIRE SPRINKLER DIAGRAMS M500 PENTHOUSE SECTIONS M501 SECTIONS M502 DETAILS M503 DETAILS M504 SEISMIC BRACING DETAILS M505 HVAC DETAILS M506 HVAC DETAILS M507 PLUMBING DETAILS M508 PIPING DETAILS M509 STEAM SYSTEM DETAILS M510 AIR HANDLING UNIT DETAILS M510A AIR HANDLING UNIT DETAILS ELECTRICAL 2E2R COMPOSITE 15kV FEEDER REMOVAL PLAN 1E7R CABLE TRAY ROUTING REMOVAL PLAN 2E7R CABLE TRAY ROUTING REMOVAL PLAN 1E1OR FIRST FLOOR LIGHTING REMOVAL PLAN 1 E11 R FIRST FLOOR LIGHTING REMOVAL PLAN 1 E12R FIRST FLOOR LIGHTING REMOVAL PLAN 1E13R FIRST FLOOR LIGHTING REMOVAL PLAN 2E1OR SECOND FLOOR LIGHTING REMOVAL PLAN 2E11R SECOND FLOOR LIGHTING REMOVAL PLAN ORIG ORIG ORIG ORIG ORIG ORIG ■ 1i • • ►TI 11 1 • 9- 90 -2E12R 9- 90.2E13R 2E12R SECOND FLOOR LIGHTING REMOVAL PLAN 2E13R SECOND FLOOR LIGHTING REMOVAL PLAN 9-90-1E112R 9- 90- 2E112R 1E112R 480Y/277 VOLT POWER REMOVAL PLAN 2E112R 480Y 277 VOLT POWER REMOVAL PLAN ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG OR!G ORIG ORIG ORIG ORIG ORIG ORIG 9- 90 -3E1OR 9--- 90 -3E11R 9-90-1E6OR 9- 90 -1E61R 9- 90 -1E62R 9- 90 -1E63R 3E1OR WEST PENTHOUSE LIGHTING REMOVAL PLAN 3E11 R EAST PENTHOUSE LIGHTING REMOVAL PLAN 1E6OR 208Y/120 VOLT POWER REMOVAL PLAN 1 E61 R 208Y/120 VOLT POWER REMOVAL PLAN 1E62R 208Y/120 VOLT POWER REMOVAL PLAN 1E63R 208Y 120 VOLT POWER REMOVAL PLAN 9- 90 -2E60R 9- 90 -2E61 R 9 -90 -2E62R 9- 90 -2E63R 9- 90 -3E60R 9- 90 -3E61 R 9 -90 -1 E111 R 2E60R 208Y/120 VOLT POWER REMOVAL PLAN 2E61R 208Y/120 VOLT POWER REMOVAL PLAN 2E62R 208Y/120 VOLT POWER REMOVAL PLAN 2E63R, 208Y/120 VOLT POWER REMOVAL PLAN 3E60R WEST PENTHOUSE POWER REMOVAL PLAN 3E61R EAST PENTHOUSE POWER REMOVAL PLAN 1 E111 R 480Y/277 VOLT POWER REMOVAL PLAN ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG OR1G INCLUDED IN SET DRAWING NO. 9- 90 -2M260 BY APPROVED SHEET NO. 2M260 DATE N CS DRAWING SUBTITLE SECOND FLOOR FIRE SPRINKLER PLAN g REV DATE VOLV 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05,07 04.05.07 04.05.07 04.05,07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05,07 04.05.07 04.05.07 04.05.07 REGISTERED ARCHITECT 0 RSE ASHINGTON 9- 90 -2E10 9- 90 -2E11 9- 90 -2E12 9- 90 -2E13 9- 90 -3E10 9- 90 -3E11 2E10 SECOND FLOOR LIGHTING PLAN 2E11 SECOND FLOOR LIGHTING PLAN 2E12 SECOND FLOOR LIGHTING PLAN 2E13 SECOND FLOOR LIGHTING PLAN 3E10 WEST PENTHOUSE LIGHTING PLAN 3E11 EAST PENTHOUSE LIGHTING PLAN 9 -90 -1 E60 9 -90 -1 E61 9 -90 -1 E62 9- 90 -1E63 9- 90 -1E64 9-90-1E110 9-90-1E111 9-90-1E112 1E60 FIRST FLOOR 208Y/120V POWER PLAN 1E61 FIRST FLOOR 208Y/.120V POWER PLAN 1E62 FIRST FLOOR 208Y/120V POWER PLAN 1 E63 FIRST FLOOR 208Y/120V POWER PLAN 1E64 _ ENLARGED FIRST FLOOR 208YL120V POWER PLAN 1E110 FIRST FLOOR 480Y/277V POWER PLAN 1E111 FIRST FLOOR 480Y/277V POWER PLAN 1E112 FIRST FLOOR 460Y 277V POWER PLAN ORIG ORIG ORIG • 0 • ■ r 0 1 • 9-90-1E113 1E113 FIRST FLOOR 480Y/277V POWER PLAN 9-90-1E360 9 -90-1 E361 1E360 FIRST FLOOR TELECOMMUNICATIONS PLAN 1E361 FIRST FLOOR TELECOMMUNICATIONS PLAN 9- 90 -1E362 9- 90 -1E363 9-90-2E60 9- 90 -2E61 9- 90 -2E62 9 -90 -2E63 9- 90 -2E110 9- 90 -2E111 9- 90 -2E112 9- 90 -2E113 9- 90 -2E260 1E362 FIRST FLOOR TELECOMMUNICATIONS PLAN 1E363 FIRST FLOOR TELECOMMUNICATIONS PLAN 2E60 SECOND FLOOR 208Y/120V POWER PLAN 2E61 SECOND FLOOR 208Y/120V POWER PLAN 2E62 SECOND FLOOR 208Y 120V POWER PLAN 2E63 SECOND FLOOR 208Y/120V POWER PLAN 2E110 SECOND FLOOR 480Y 277V POWER PLAN 2E111 SECOND FLOOR 480Y/277V POWER PLAN 2E112 SECOND FLOOR 480Y/277V POWER PLAN 2E113 SECOND FLOOR 480Y/277V POWER PLAN 2E260 SECOND FLOOR FIRE ALARM PLAN 9- 90 -2E261 9-90-2E262 9 -90 -2E263 9- 90 -2E360 9- 90- -2E361 9 -90 -2E362 9-90-2E363 2E261 SECOND FLOOR FIRE ALARM PLAN 2E262 SECOND FLOOR FIRE ALARM PLAN 2E263 SECOND FLOOR FIRE ALARM PLAN 2E360 SECOND FLOOR TELECOMMUNICATIONS PLAN 2E361 SECOND FLOOR TELECOMMUNICATIONS PLAN 2E362 SECOND FLOOR TELECOMMUNICATIONS PLAN 2E363 SECOND FLOOR TELECOMMUNICATIONS PLAN 9- 90 -3E60 3E60 PENTHOUSE POWER PLAN 9- 90 -3E260 3E260 PENTHOUSE FIRE ALARM PLAN 9- 90 -E4A 9 -90 -E8 Q REV ORIG ORIG ORIG OR1G ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG 9-90-1E262 1E260 FIRST FLOOR FIRE ALARM PLAN 1E261 FIRST FLOOR FIRE ALARM PLAN 1E262 FIRST FLOOR FIRE ALARM PLAN 1E263 FIRST FLOOR FIRE ALARM PLAN ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG INCLUDED IN SET DRAWING NO. 9-90-E4AR 9-90-E4R • • 9-90-E0 O 9-90 1E7 • 9 90-2E7 • 9-90-1E13 9-90-E4 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE 1 2 SHEET NO, DRAWING SUBTITLE E4AR WEST PENTHOUSE ONE-LINE REMOVAL DIAGRAM E4R EAST PENTHOUSE ONE-LINE REMOVAL DIAGRAM E0 LIGHTING FIXTURE SCHEDULE 2E7 1E12 FIRST FLOOR LIGHTING PLAN E4 ONE-LINE DIAG.-SUBSTATION NO. 51-EAST PENT. E4A ONE-LINE DIAG.-SUBSTATION NO 25-WEST PENT. E8 OUTDOOR LIGHTING PLAN 2E2 COMPOSITE 15kV FEEDER PLAN (FOR REF ONLY) DRAWN DM GROUP CHECKED CHECKED APPROVED APPROVED DATE FIRST FLOOR LIGHTING PLAN FIRST FLOOR LIGHTING PLAN FIRST FLOOR LIGHTING PLAN SUBTITLE . ARCHITECTURAL MASTER FIRST FLOOR COMPOSITE CABLE TRAY PLAN SECOND FLOOR COMPOSITE CABLE TRAY PLAN ORIG INDEX OF DRAWINGS - VOLUME 2 9-90 RENOVATION BUILDING 9-90 DATE 04.05.07 04.05.07 04.05.07 04 05.07 04.05 07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04 05 07 04.05.07 04.05 07 04.05.07 04.05.07 04.05 07 04.05.07 04.05 07 04.05.07 04.05.07 04.05 07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05 07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04 05 07 04.05.07 04.05.07 04.05 07 04 05 07 04.05.07 ISSUE FOR PERMIT DEV. CENTER, WA JOB NO. DWG NO. PREL ORIG A CURRENT REVISION SHEEr ISSUE LEGEND NOT YET ISSUED PREVIOUSLY ISSUED FOR CONSTRUCTION PREVIOUSLY ISSUED, BUT NOT IN THIS ISSUE INCLUDED IN THIS ISSUE G3 150680-01 PRELIMINARY ISSUE FOR REVIEW OR INFORMATION ONLY NOT FOR CONSTRUCTION ORIGINAL ISSUE FOR PERMIT, BID, PROCUREMENT OR CONSTRUCTION DRAWING REVISION - SEE SPECIFIC DRAWING FOR NATURE OF REVISION CODE COMPLIANCE APPROVED City Of TIACW BUILDING DW.1.517. CITY OF T1 MI/WU APR 0 9 2007 DLR Group Architecture Engineering Planning Interiors 'ORIC DATE 09-090-G3 COMP NO. COMPUTER ROOM COOLING UNIT (AC' SCHEDULE MARK NUMBER LOCATION (ROOM NUMBER} MAKE CONNECTION (INCHES) MODEL NOMINAL CAPACITY TONS FAN FAN MOTOR COIL COOLING CAPACITY CHILLED WATER AIR FILTER ELECTRICAL REMARKS TYPE & DEPTH EFFICIENCY PER ASHRAE 52.76 MAX FINAL SP WG VOLTS PHASE FLA WSA MFCB DRIVE TYPE CAPACITY (CFM) ESP IN WG HP CAPACITY 1000 BTU /HR ROO TEMP ROOM ('F) FLOW GPM EWT 'F MAX PD © MAX FLOW FT H2O SENSIBLE TOTAL DB AC1K8 DCN RM 11J7 LIEBERT MINI- -MATE2 WALL -HUNG FLUSH VALVE MMD92C 5 DIRECT 2500 0.5 1.5 59,000 67,100 75 10 45 7.6 2 30% - 208 3 2.8 3.5 15 FACTORY FILTER BOX, FILTER CLOG SWITCH, 2 WAY VALVE, CONDENSATE PUMP, AUXILIARY DRAIN PAN, LIQUI -TECT LEAK DETECTION SENSOR WITH A 6' LONG WIRE TO UNIT, SMOKE DETECTOR, DISCONNECT AC1K7 ELEV EQ 13J6 LIEBERT MINI -MATE2 - MMD23C 1.5 DIRECT 750 0.3 0.2 14,900 , 15,700 75 3.1 45 4.2 2 . 30% ,. - 208 3 1.4 1,8 15 FACTORY FILTER BOX, FILTER CLOG SWITCH, 2 WAY VALVE, CONDENSATE PUMP, AUXILIARY DRAIN PAN, 410 POINT LEAK DETECTION SENSOR WITH A 6' LONG WIRE TO UNIT, DISCONNECT AC1 E10 SoSAC SERVER LIEBERT SYSTEM 3 WALL HUNG FH302C 15 BELT 9,300 0.35 (2) 5 185,200 206,200 75 45.0 45 11.9 4 60% - 208 3 98.8 123,5 125 (2) 5 HP FAN MOTORS, 2 WAY VALVE, 28.9 CV, DOWN FLOW MODEL WITH 12 "HIGH SEISMIC ZONE 4 FLOOR STAND W/ BRACING FOR CONTRACTOR PROVIDED TURNING VANES, FACTORY RETURN PLENUM W /GRILLE, CONDENSATE PUMP, INFRARED HUMIDIFIER, ELECTRIC HEAT 81.0 MBH, LIQUI -TECT WATER DETECTION, HIGH EFFICIENCY FILTERS, SMOKE DETECTOR, DISCONNECT AC1 E9 SoSAC SERVER LIEBERT "XD" SYSTEM FLOOR MOUNTED XDP 46 -- - - - 546,080 - - 140 45 41 -- - - 208 3 4.0 -- -- SPLIT SYSTEM, CONDENSATE DETECTION, XD PIPING SYSTEM & VALVES AC1 E9a SoSAC SERVER UEBERT "XD" SYSTEM (2) XDO 5.7 - -- - - - - - - - _ - - - 120 1 2,7 ea. - -- EXTERNAL MOUNTING BRACKET, (3) BYPASS FLOW CONTROL VALVES, CONDENSATE DETECTION, (5 FUTURE) AC1 F10 SoSAS SERVER LIEBERT SYSTEM 3 FH302C 15 BELT 9,300 0.35 (2) 5 185,200 206,200 75 45.0 45 11.9 4 60% - 208 3 98.8 123.5 125 (2) 5 HP FAN MOTORS, 2 WAY VALVE, 28.9 CV, DOWN FLOW MODEL WITH 12 "HIGH SEISMIC ZONE 4 FLOOR STAND W/ BRACING FOR CONTRACTOR PROVIDED TURNING VANES, FACTORY RETURN PLENUM W /GRILLE, CONDENSATE PUMP, INFRARED HUMIDIFIER, ELECTRIC HEAT 81.0 MBH, UQUI -TECT WATER DETECTION, HIGH EFFICIENCY FILTERS, SMOKE DETECTOR, DISCONNECT AC1 F9 SoSAS SERVER LIEBERT "XD" SYSTEM XDP 46 - - - - 546,080 - - 140 45 41 - - - 208 3 4.0 -- - SPLIT SYSTEM, CONDENSATE DETECTION, XD PIPING SYSTEM & VALVES AC1F9a SoSAS SERVER LIEBERT "XD" SYSTEM (5) XDO 5.7 - - - -- , . - ' - - - - - - - - 120 1 2.7 ea. - - EXTERNAL MOUNTING BRACKET, (2) BYPASS FLOW CONTROL VALVES, CONDENSATE DETECTION, (3 FUTURE) AC1H7 SoSAU SERVERS LIEBERT SYSTEM 3 1 UH248C 12.5 BELT 5,900 0.3 3 149,700 190,000 75 37.6 45 19.1 4 60% -- 208 3 65.5 81.9 90 (1) 3 HP FAN MOTOR, 2 WAY VALVE, 28.9 CV, UP -FLOW MODEL WITH FACTORY DISCHARGE PLENUM, CONDENSATE PUMP, INFRARED HUMIDIFIER, ELECTRIC HEAT 58.8 MBH, LIQUI-TECT WATER DETECTION, HIGH EFFICIENCY FILTERS, SMOKE DETECTOR, DISCONNECT AC1D12 SoSAC BLUE TEAM LIEBERT DATAMATE DME044C -PC 3 DIRECT 1320 0.3 .27 24800 26900 75 7.5 45 10.4 2 - - 208 1 2.2 2.8 15 2 WAY VALVE, CONDENSATE PUMP, LIQUI -TECT WATER DETECTION SENSOR AC1 E12 SoSAC BLUE TEAM LIEBERT DATAMATE DME044C -PC 3 DIRECT 1320 0.3 .27 24800 26900 75 7.5 45 10.4 ' 2 - --- 208 1 2.2 2.8 15 2 WAY VALVE, CONDENSATE PUMP, LIQUI-TECT WATER DETECTION SENSOR AC1 F12 SoSAC RED TEAM LIEBERT DATAMATE DME044C -PC 3 DIRECT 1320 0.3 .27 24800 26900 75 7.5 45 10.4 2 - - 208 1 2.2 2.8 15 2 WAY VALVE, CONDENSATE PUMP, LIQUI -TECT WATER DETECTION SENSOR AC1 K9 SoSAC BLUE TEAM UEBERT DATAMATE DME044C -PC 3 DIRECT 1320 0.3 .27 24800 26900 75 7.5 45 10.4 2 -- - 208 1 2.2 2.8 15 2 WAY VALVE, CONDENSATE PUMP, LIQUI -TECT WATER DETECTION SENSOR AC1 K10 SoSAC RED TEAM LIEBERT DATAMATE DME044C -PC 3 DIRECT 1320 0.3 A .27 24800 26900 75 7.5 45 10.4 2 - - 208 1 2.2 2.8 15 2 WAY VALVE, CONDENSATE PUMP, LIQUI-TECT WATER DETECTION SENSOR AC2J7 DNC RM 21J6 LIEBERT MINI -MATE2 MMD40C 3 DIRECT 1250 0.3 0.5 27305 30085 75 6 45 5.7 2 30% -- 208 3 2.8 3.5 15 FACTORY FILTER BOX, FILTER CLOG SWITCH, 2 WAY VALVE, CONDENSATE PUMP, AUXILIARY DRAIN PAN, LIQUI-TECT LEAK DETECTION SENSOR WITH A 6' LONG WIRE TO UNIT, DISCONNECT PLUMBING FIXTURE SCHEDULE SCHEDULE MARK NUMBER DESCRIPTION CONNECTION (INCHES) TEMP T TYPE REMARKS BASIS OF DESIGN SAN VENT HW CW SERVICE DATE FIXTURE FAUCET / FLUSH VALVE (MIXING VALVE) SPOUT OR ACCESSORY DRAIN TYPE P -1 WATER CLOSET 4 2 - 1 -1/4 WALL-HUNG HP KOHLER KINGSTON K-4330 SLOAN OPTIMA ROYAL NO. 111 ES SEAT: OLSONITE 95SSC RPM P -2 URINAL 2 1. --1/2 --- 3/4 1 WALL -HUNG FLUSH VALVE (H) HANDICAP KOHLER BARDON K -4960 ET SLOAN SP- S186-- 10.ES- S--BOE W /EL 518- A -BOE 50 - P -3 LAVATORY 1--1 /2 1 -1 /2 1/2 1/2 INLINE COUNTERTOP ELEC. SENSOR (120V TO COMMON TRANSFORMER) KOHLER INVITATION • K-2098 - SLOAN ETF-600 TRANSFORMER ELF- 154(ONE PER 3 LAVATORIES) SUMP PUMP WATER P-4 LAVATORY -1/2 1-1/2 1/2 1/2 - WALL HUNG DEDICATED TRANSFORMER KOHLER CHESAPEAKE K -1728 (4"CENTERS) SLOAN ETF -600 TRANSFORMER ELF -154 0.33 115 P -5 SHOWER 2 1 -1 /2 1 /2 1 /2 GELCOAT STALL W/ GRAB BARS &SEAT SET STALL, ON FULL BED GROUT STALL: LASCO 1603 BFSC COLOR: . BONE CHICAGO 17621S BRASS BODY W/ STAINLESS STEEL GRID P -6 ELECTRIC WATER COOLER 1--1 /2 1 -1 /2 --- 1 /2 , WALL HUNG PROVIDE WATER FILTER 4.5 AMP AT 120V -1 PH ELKAY EROM28RAC �-1 f 2" FILTER: EVERPURE 9-1/2" H54 SERIES W /QL -3 HEAD P -7 SINK 2 1 -1 /2 1 /2 1 /2 SINGLE COMPARTMENT COUNTERTOP, STAINLESS STEEL UNDER MOUNTED -REFER TO ARCH'L FOR COUNTER DETAILS ELKAY ELU -1616 CHICAGO 201 AHA-8 GRID P -8 SERVICE SINK 3 2 1/2 1/2 FLOOR MOUNTED KOHLER WHITBY 6710 W /GUARD CHICAGO 956R -369 FD -1 FLOOR DRAIN VARIES VARIES - -- 1 /2 "TRAP PRIMER (SAN ONLY) SEE PLAN FOR SIZE SMITH 2010 -B STRAINER:SQUARE NICKLE - BRONZE FD -2 FLOOR DRAIN VARIES VARIES - - 1 /2 "TRAP PRIMER SEE PLAN FOR SIZE SMITH 2630 FED-1 FLOOR DRAIN VARIES VARIES - -- 1/2 "TRAP PRIMER SEE PLAN FOR SIZE SMITH 3510 -F19 PUMP (u) SCHEDULE MARK NUMBER SERVICE FLUID TEMP T CAPACITY SIZE (IN) CONSTRUCTION PERFORMANCE MOTOR PUMP TYPE BASIS OF DESIGN SERVICE DATE REMARKS GPM TDH SUCT LB /HR DISCH BODY FITTINGS F NPSHR DRIVE TYPE HP VOLTS PH HZ RPM PUPIGSA DOMESTIC HOT WATER RECIRC WATER 120 5.0 25 1 2 1 BRONZE BRONZE 50 - DIRECT 0.25 115 1 60 1750 INLINE BELL Sc GOSSETT SERIES 60 START /STOP AS PROGRAMMED BY BUILDING DDC SYSTEM PUUGW6A SUMP PUMP WATER - 35 15 - 1 -1/4 - --- -- - -- 0.33 115 1 60 1800 SUBMERSIBLE PACO ASA SELF CONTAINED START /STOP SEMI - INSTANTANEOUS WATER HEATER SCHEDULE TAG SERVES LOCATION MWP (PSIG) CAPACITY (GPM) INLET TEMP T OUTLET TEMP 'F CONNECTIONS (IN.) STEAM COND. PSIG UNIT POWER REQUIREMENTS UNIT WEIGHT FULL (LBS) BASIS OF DESIGN SERVICE DATE REMARKS CW HW LB /HR PSIG VOLTS PHASE AMPS WHP1 G5A DOMESTIC PENTHOUSE 150 @300`F 18 40 120 1.25 1.25 720 15 2 115 1 2 PATTERSON -KELLY PK 06D DOUBLE WALL HEAT EXCHANGER PROVIDE W/ F &T TRAP. ASME (SECTION 8) VESSEL BACKFLOW PREVENTER SCHEDULE MARK NUMBER SERVICE DEVICE SIZE (INCHES) TYPE CAPACITY BASIS OF DESIGN GPM PD (P51) BF1 D71A DOMESTIC WATER SERVICE 3 REDUCED PRESSURE 200 13 WILKINS 37T BF1 D71B DOMESTIC WATER SERVICE 1 -1/2 REDUCED PRESSURE 100 15 WILKINS 975 BF1 V61A IRRIGATION WATER 2-1/2 DOUBLE CHECK 100 6 WILKINS 350 MFCB - MAXIMUM FUSE OR CIRCUIT BREAKER WSA - WIRE SIZING AMPS FLA - FULL LOAD AMPS ISSUE FOR PERMIT ACOFFMAN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 205 623 0717 Fax 206 624 3775 SHEET 4u � , � A$ E CODE ; ED ORIG 9 -90 RENOVATION J *150680.01 COFFMAN M.SOTURA 04.05.07 APPROVED DATE MN MIN gLAinswirma® MIN =II SORES 1/10 00 403 19 0 . 7, 7 8114'4 TT 1 1 APPROVED BY ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. DATE COFFMAN CHECKED M.SOTURA DATE 1 15.07 01.15.07 SYM REVISION APPROVED DATE SYM REVISION SUBTITLE TITLE MECHANICAL MASTER MECHANICAL SCHEDULES 9 -90 RENOVATION BUILDING 9 -90 DEV. CENTER,WA CURRENT REVISION JOB NO, 'DWG NO. 150680 -01 9- 90 --M2B COMP NO. 04.05.07 M26 SYMBOL0 R 1 G DATE cnY Tu . ' APR 0 9 2007 PERMIT CENIL 6 "-' 1_1 /2"PW -' -2 f, �. J1_1 /2 "pw 4 Z � \` 1--1 /2 PW U P 1 1 / ff 4 "W UP 5 "RD UP 5 "RD UP \ UP 3" 4 „ / (GRAVITY) 5 RD UP � 4 / FCO L.. 4 "W U ..MI 3 "RD UP III �- RD • f 1 -14.00 ti► 2 —MH1- IL 6" -- -- - - f 1 6" UP TO _ RD --� 1 • 2ff 1M452 W 4' O ” A L -- 1 1 HUB DRAIN A� y 4 1 6 2 "W UP IN ELEVATOR 3 "V UP ; 3 "V UP i IT � 1 �� PLUG i UGM450 1 4 " 6 HUB �c o CAP UGM450 DRAIN C - - - - - fX " PW 0 FCO ABANDON FCO ` » 1 - 1 2 � _ - - - - � ei I. CAP — � r-i 6 4 " 6 .■■ 5 " RD UP P ■■.r U P / ■ t 1 RD _ ► - RD l'h /4 --7,.=,- - lib li 011 FCO • II i Iii Illf „ MI 4 J 4"W O ff 6 „ • , r Ew _._ 6 "RD UP t 8" 2 "V UP UP i ii -- 5 "RD UP w � / 6" ±IE=12.60' FC - � 1 -1 /2 "PW UP 12.6 0 _....__ _....- _._..__. _ _ t C1P t .. i. 4"W UP 8" -1--1 /2 "PW 4, ( 1 1 LL Y 8 "F UP 8 "F UP � A f' - - 1 �_ T r �J E .� I�M .�■. J - mar— . . . •. '6 . . � C7 -u ` � L I � C m C9 _ _ .� " '�'r r C � �.... -... - - w_ - - - .. Li -- ' I I _ !7 C C9 ! !7 — 1- _ Ir. . 2 C C e ea � to — 1 — ._ T T_. �_ 1 _ .� I �� t _ � m_.... _ .-.4 _ -- - NV M al WI 1----T-- I - - 7 . .. . ..m E EN anis E Ens - --- ' ' !III T TT TT Tff 7a 1 E EXIST 6 "� L 11 1 11 1 6 CW UP R R REFERENCE ONLY > LC) J LIJ 1:) O U � Q u- 4 W �0 o ° U LL iI 1 11 1 r -- - - T T o co - - I yU Ula1VIJ 1 tNIVll 1 G VUr I -'/-am 1 - 4 /O /GUU/ J:JO.G r lVI SYM ORIG 9 -90 RENOVATION A REVISION J #150680 --01 BY COFFMAN APPROVED M. SOTURA DATE 04.05.07 SYM REVISION SCALE: 1/16"= 1 -0" BY APPROVED DATE COMPOSITE WDERGROUND PLU vIBING P ci,AirDWAFAW® S _AN ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE CHECKED APPROVED ISSUE FOR PERMIT DRAWN COFFMAN CHECKED M. SOTURA ENGINEER DATE 01.15.07 01.15.07 SUBTITLE TITLE # RD ACOFFMAN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 COMPOSITE UNDERGROUND PLUMBING PLAN 9 -90 RENOVATION BUILDING 9 -90.UG LEGE PW PROCESS WATER RD ROOF DRAIN F FIRE LINE V VENT W WASTE 0 VENT THROUGH ROOF FLOOR DRAIN GE\ 0 FCO D FLOOR CLEANOUT �-- PIPE ELBOW, TURNED UP OR TOWARDS �+-- PIPE ELBOW, TURNED DOWN OR AWAY POINT OF CONNECTION CAP ERAL \OTES REFERE \CE DRAWINGS UGM450 ENLARGED UNDERGROUND DRAINAGE PLANS 1M450 ENLARGED TOILET ROOM DOMESTIC WATER PLANS 1M451 ENLARGED TOILET ROOM DRAINAGE PLANS 1 M452 ENLARGED MECHANICAL ROOM PLANS 1M1 10 FIRST FLOOR PLUMBING PLAN 1 M111 FIRST FLOOR PLUMBING PLAN 1M112 FIRST FLOOR PLUMBING PLAN 1M113 FIRST FLOOR PLUMBING PLAN copE O MPLC C f NCE OVER SIOVA 4.J X 19 P �� 3�D DV 140 `2, .') 201 \ Co \STRUC NOTES 16' 8' CURRENT REVISION SHEET JOB NO. KEY PLAN SCALE: NONE 150680-01 0 0 • 0 0 8' 16' MIN OMNI— SCALE: 1/16"=1'-0" UGM3 s 'ORIG DATE cily tap A APR g29 2007 COMP NO. 04.05.07 SYM ORIG 9 -90 RENOVATION REVISION ( -- 0 FEC WHITE 1201 CONFERENCE 12C11 4150680 -01 AC1 E12 BY COFFMAN AC1 F12 PC PC. PC APPROVED M. SOTURA DOD WORK SPACE 110 11 DATE 04.05.07 SOSAC BLUE TEAM 11D11 11E11 SYM 1 r " SOSAC SERVFR 13010 U ■o4dril.1 ir44 \JTC CONFERENCE 11010 6 "RD UP &DN REVISION 2 "V DN 1 /2 "CW 4 "FS- -1 C 3 "V UP , v—P 11E7 JAN. (E) FCO MECH. 1106 j oi■ t MI MIMMINNIM — — APPROVED 6" ELECT. 12D6 CONFERENCE 7 ST. 13C6 i iii_i DATE STORAGE 11E6 FIRST FLOOR PLUVIBI SCALE: ,ia ,.-0 UP STAIR 1M452 r 12C6 1M450/1M451 S 1 r — I IOI i i r vc P_AN CONFERENCE 1185 �BOE /NG 5 "RD UP &DN CONFERENCE 11E5 6 " ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY CW OPEN OFFICE 11A5 6 "CW DN CONNECT TO EXIST 6 "CW DEPT. DATE ENGINEER CHECKED AP DRAWN COFFMAN CHECKED M. SOTURA PROVED DATE 01.15.07 01.15.07 ( SUBTITLE MECHANICAL MASTER cA) ISSUE FOR PERMIT N OFFMAN G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 FIRST FLOOR PLUMBING PLAN 9 -90 RENOVATION BUILDING 9 -90.1 COL. A— F/1 -13 LEGEND C - CW HW HWC PW - PC 1,0'1 0 CC DEV. CENTER,WA GENERAL NOTES CONDENSATE RETURN (GRAVITY) DOMESTIC COLD WATER DOMESTIC HOT WATER SUPPLY DOMESTIC HOT WATER CIRCULATING PROCESS WATER CONDENSATE RETURN (PUMPED) BUTTERFLY VALVE VENT THROUGH ROOF WATER HAMMER ARRESTOR BALL VALVE, OPEN PIPE ELBOW, TURNED UP OR TOWARD PIPE ELBOW TURNED DOWN OR AWAY REFERENCE DRAWINGS CODE covwuNtAce PRPRO VIM \ STRUCTION NOTES ROUTE 3/4" PUMPED CONDENSATE DOWN IN WALL. ROUTE CONDENSATE IN SPACE BELOW RAISED FLOOR. KEY PLAN SCALE: NONE 8' 4' CURRENT REVISION SHEET I� 1M112 1M113 JOB NO. SCALE: 1 /8 "- 1'--0' DWG N0. 1M110 150680 -01 SYMBOL RIG 9-90-1M110 DATE COMP NO. 04.05.07 ail 16 'APR0921 Or Tw PEN .ITl� :a_ u , c i ai r C a n' KEY PLAN APR o 0 2007 ISSUE FRPERI�IIT COFFMAN SCALE: NONE I'E.A�tT GEN ■ �., NG�eE� 8 ' 4' 0 4' 8' 16' 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 S CALE: 1 8 "- 1'--O" 206 623 0717 Fax 206 624 3775 – SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE i 11 PI ird FA FA W o � • o T i. `'` / ` oral. a __ A . J � ` ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN COFFMAN DATE 01.15.07 SUBTITLE FIRST FLOOR PLUMBING PLAN CURRENT REVISION SYMBOL^ U DATE 04.05.07 ORIG 9-90 RENOVATION J #150680 -01 COFFMAN M. SOTURA 04.05.07 �C ED M. SOTIIRA 01.15.07 SHEET 1.1 Ell 1 IM ENGINEER TITLE 9 -90 RENOVATION BUILDING 9 MECHANICAL MASTER COL. F– L/1 --13 DEV. CENTER,WA APPROVED BY DEPT. DATE ` CHECKED J OB NO. 150680 -01 COMP NO. 'APPROVED DWG No. 9-90-1M111 APPROVED °em 9/21/07 I I ii:1 r.n SOSAC CONFERENCE 11F12 T SOSAS WORK SPACE CLASSIFIED CONTROL 11K11 CLASSIFIED CONTROL 12K11 0 CONFE �OSAS FERENCE 3G10 RENCE a SOSAS RED TEAM 12,110 OFFICE 11K1O SOSAS 4,�W UP SERVER 11010 4 "W DN 3• 0 r r T=7L SOSAS BLUE TEAM 5 "RD DN 5 "RD UP 11K9 j OPEN OFFICE !1 __ m.romr, _. MErrl rrnr __ ■••••__■■rwrm••■■■■=raldarmarrt.irr _ __ __ r rrirra __ 1 1� 1 0000 SOSAU SERVER DCN 11J7 IS El 1M450/1 M451 BLUE TEAM FPI 12J6 ELEV. E 13J6 FIRST FLOOR PLUNBIN UP G I N 1M452 P_AN 1 /2'CW U 1-1 ) UP 1 -1 4 4 "W UP 3 "V UP CONFERENCE 13F4 4 "W UP&DN --�– 5 "RD UP &DN 12L3 P IVACY 112F4 CONFERENCE r 1- WORK ROOM 13F3 3 ' OFFICE 11F3 OFFICE 12F3 OPEN OFFICE 1105 HUDDLE 11F2 arrorml _. __ _r._..._., • WIVIMMMO __ __ _. LEGEND C - CONDENSATE RETURN (GRAVITY) CW— DOMESTIC COLD WATER HW DOMESTIC HOT WATER SUPPLY HWC DOMESTIC HOT WATER CIRCULATING -PW PROCESS WATER PC CONDENSATE RETURN (PUMPED) BUTTERFLY VALVE VENT THROUGH ROOF WATER HAMMER ARRESTOR BALL VALVE, OPEN at— PIPE ELBOW, TURNED UP OR TOWARD c—t- -- PIPE ELBOW TURNED DOWN OR AWAY GENERAL NOTES REFERENCE DRAWINGS VO Otl CONSTRUCTION I\ © O1 iM11 1M11 1M112 1M113 0 0 OTES FIE-CEP/ED are o Ti 9-90 RENOVATION PROVIDE NEW HOSE BIBB, CONN TO PW BELOW SLAB eK REVISION C-1FlED CONTROL 12K11 ESTIBULE S1 J#150680 --01 BY COFFMAN FEC MAIL __ ww __ ■■■•.. __ .,_ ...__ __ - .,._..,w APPROVED M. SOTURA DATE 04.05.07 BIKE RACK STATION RECYC. 12L10- OPEN OFFICE OPEN OFFICE 11S8 SYM -OPEN OF'ft0 --- 11K9 CONNECT TO EXISTING AT FLOOR 1-1/2'=, REVISION OFFICE 111M9 3 " ▪ Imm• ` -- —f Rmrrr, r. —_ __— I-- --w ._■i- -- rr _. . I . .. .rfr•• - C BY { P -7 icpt V - 2 "V UP VTC EQUIP. [ 11P7 FCS VTC 11R7 r. _r ___._. -. Y.IM. ._ w_ ._ .. FIRST FLOOR PLUMBING PJ\N SCALE: 1/8". 1'--O" APPROVED DATE CAFE CONNECT TO EXISTING AT FLOOR 4 "W ON 4 "W UP TO1 1___-k L 1 C) F a. �--1 -1 /2" 7E7A ® U CONFERENCE r 1 L3 12L3 1 _ 1/2, CONFERENC 11L3 CONFERENCE 13P3 PROGRAM STOR. 12P3 5 "RD UP &DN 4 "W UP &DN OFFICE 11M3 STOR. 11N3 WORK ROOM 12N3 FEC -Ea OPEN OFFICE 12L2 OPEN OFFICE 11R5 _rrwrw.w_. _. _. arra -_ r rw .M , m 1 1■+- -+ r- __ y- ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE ISSUE FOR PERMIT DRAWN COFFMAN CI-IEC ED M. SOTURA ENGINEER CHECKED APPROVED APPROVED VESTIBULE N1 CONFERENCE �11 DATE SUBTffLE 01.15.07 01.15.07 PROTECT IRRIGATION CONTROL VALVES AND ACCESSORIES ACOFFMAN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 FIRST FLOOR PLUMBING PLAN 9-90 RENOVATION BUILDING 9 -90.1 MECHANICAL MASTER COL. L- S/1 -13 LEGEND - Cw NW HWC - Pw GE C-4— DEV. CENTER,WA 01 — ERAL CURRENT REVISION SHEET JOB NO. DWG NO. ot DOMESTIC COLD WATER DOMESTIC HOT WATER SUPPLY DOMESTIC HOT WATER CIRCULATING PROCESS WATER BUTTERFLY VALVE VENT THROUGH ROOF WATER HAMMER ARRESTOR BALL VALVE, OPEN PIPE ELBOW, TURNED UP OR TOWARD PIPE ELBOW TURNED DOWN OR AWAY \OTES REFERENCE DRAWINGS CONSTRUCTION NOTES 1M110 1M111 1M113 1M112 150680 -01 'ORIG 9 --90 -1 M112 RECEIVED CITY (3 TI JKWILA APR 0 9 2007 PERMIT Ceti; 8' 4' 0 4' 8' 16' SCALE: 1/8".1'-0" DATE 04.05.07 COMP NO. REVISION 11X11 OPEN OFFICE OPEN OFFICE 11U8 BY APPROVED DATE SYM 1 -1/2" OFFICE OFFICE REVISION CONFERENCE 13T9 1 - /2 "PW DN, CONNECT TO EXISTING AT FLOOR (TYP) a_ CONFERENCE I 11W8 FE FE 5 "RD UP &DN WCO 3" 11 I I JAN 1157 a 0 .. � .M.or 'MI - ...ww w IM MOTHER'S ROOM 11T7 1111=11•11100 leel BY APPROVED L 3" UP TO RD DATE s L..—J 11 N6 1 Z -1 /2 "CWT FIRST FLOOR PLU SCALE: ,fie•- r o 1M450/1M451 3 1M452 TI �-- z - 1i2 °'P 2- VIBING PLAN PW I 0 �BOE /NG 3 "RD DN 3 "RD UP 11W5 1 - 1/2 CONFERENCE 354 1---1 /2 "PW DN, CONNECT TO EXISTING AT FLOOR (TYP) CONFERENCE FEC �-- WALL HOSE BIBB P 2IVACY PRIVACY 2S4 WORK ROOM 1353 OFFICE - 1 /2 "PW DN, CONNECT TO EXISTING AT FLO R (TYP) �- RELOCATED IRRIGATION CONTROL VALVE AND ACCESSORIES DEPT. DATE ENGINEER CHECKED APPROVED ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION iS APPROVED APPROVED BY OPEN OFFICE 11T5 DRAWN COFFMAN CHEC ED M. SOTIJRA APPROVED HUDDL I 1152 DATE 01.15.07 01.15.07 SUBTTILE PROTECT IRRIGATION CONTROL VALVES AND ACCESSORIES MECHANICAL MASTER ISSUE FOR PERMIT ACOFFMAN N G 1 N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 --1625 206 623 0717 Fax 206 624 3775 FIRST FLOOR PLUMBING PLAN 9-90 RENOVATION BUILDING 9 -90.1 COL. S- Y/1 -13 DEV. CENTER,WA LEGEND CW DOMESTIC COLD WATER HW DOMESTIC HOT WATER SUPPLY HWC DOMESTIC HOT WATER CIRCULATING PW GEN IP' I 0 ERAL NOTES REFERENCE DRAWINGS CON 8' SHEET 4' PROCESS WATER BUTTERFLY VALVE VENT THROUGH ROOF WATER HAMMER ARRESTOR BALL VALVE, OPEN PIPE ELBOW, TURNED UP OR TOWARD PIPE ELBOW TURNED DOWN OR AWAY STRUCTION NOTES © tO 1M170 1M110 1M111 0 1M112 1M112 1M113 z KEY PLAN SCALE: NONE 0 4' 8' neceivED are 07 TLIKwrlit APR 0 9 2007 PEASIICE TE4 16' JOB NO. DWG NO SCALE: 1/8"=1'-0" CURRENT REVISION sYmBaoRic 1M113 150680 --01 9-90-1M113 DATE 04.05.07 COMP NO. C 0 • SYM ORIG 9 -90 RENOVATION REVISION OFFICE 21B11 OFFICE 22D11 WORK ROOM 21C9 1 COUEEREN.CE ___L J #150680 --01 BY COFFMAN APPROVED M. SOTURA OPEN OFFICE 21B8 DATE OF 04.05.07 -ICE 21E10 WAITING 21010 OFFICE 21010 OFFICE 22E9 OFFICE 21E9 REVISION CONFERENCE 23E9 4" UP TO RD t 1 6 "RD DN 1 1 BY 2" UP TO RD illg JAN. 2107! MEN 21E7 APPROVED 1 11111111111 1111 1111111 DN STAIR MIMI IIIIIIIIII 3 V DN & VTR CAFE 2106 DATE ELEC. 2206 SECOND FLOOR PLUV SCALE: 1/8'= 1' -0" 2106 2M450/2M451 r 1 1 1 0t1111 1111M1 2" UP TO RD 4 "RD DN 1 1 1 1 II t t 1 I / 1 1 1 I BING PLAN 4" UP TO RD g DOM 9/21/07 RD APPROVED BY OPEN OFFICE 21A5 HUDDLE 21A2 ISSUE FOR PERMIT DEPT. CHECKED APPROVED ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN COFFMAN CHECKED M. SOTURA 'ENGINEER APPROVED DATE SUBTRLE 01.15.07 01.15.07 TITLE MECHANICAL MASTER OO AOFFMAN N G I N E E K S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 SECOND FLOOR PLUMBING PLAN 9-90 RENOVATION BUILDING 9 -90.1 COL. A- F/1 --13 DEV, CENTER,WA LEGEND CW — - HW HWC - PW Isi a —R GENERAL NOTES DOMESTIC COLD WATER DOMESTIC HOT WATER SUPPLY DOMESTIC HOT WATER CIRCULATING PROCESS WATER BUTTERFLY VALVE VENT THROUGH ROOF WATER HAMMER ARRESTOR BALL VALVE, OPEN PIPE ELBOW, TURNED UP OR TOWARD PIPE ELBOW TURNED DOWN OR AWAY REFERENCE DRAWINGS CONSTRUCTION NOTES 13 0 2M112 2M113 0 0 0 0 KEY PLAN SCALE: NONE 8' 4' 0 SCALE: 1/8"=1'-0" CURRENT REVISION SHEET JOB NO. DWG NO. 4' 2M110 8' "' J 150680 -01 9- 90 -2M110 COMP NO. RECEIVED ern? o TimevoLA APR 0 9 2007 16' DATE 04.05.07 9 -90 RENOVATION REVISION J1150680 --01 OPEN OFFICE 21F8 BY COFFMAN APPROVED M. SOTURA DATE 04.05.07 SYM 4 "W UP VTC —OCC CONFERENCE 21 H9 CONFERENCE 1/2" HWC REVISION 9 EQU I9. I , i OP N OFFICE 5" 21 K8 __ .. __ _. __ Y_� .tl,.. tl_`.,.vS_ __.....tl�_., fl 4" UP TO FD CLASSR AC2 3/4" .,- J7 3/4 "A UP DCN PROVIDE 1-1/2 A.D. BELOW COUNTERITOP ;STANDPIPE DRAIN W/ 0 ! 2M45 /2M451 QOM -- 111111[1111111 1111111 STAIR WOMEN 1 1 BY APPROVED DATE 1 3/4 "A DN 2 "V UI , 3 "V UPI 4 "W UP TO D 1 -1 A4 UP 3 "V 4 "W \P-7 /1 1 -1 /4 "HW CAFE ,, 4!'C DN TO 21 J6' / STAhilDPIPE DRAI BELOW OUNTE „I ' 5 "RD jDN __ SECOND FLOOR PLUVIBING PAN 4 "W UP 2 "V UP �BOE /NG mums 9/21/07 1.....i. WORK ROOM 23F3 OPEN OFFICE 21 K5 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED OFFICE 21F3 OFFICE 22F3 APPROVED BY DEPT. DATE OPEN OFFICE 2105 DRAWN COFFMAN CHECKED M. SOTURA ENGINEER CHECKED APPROVED APPROVED HUDDLE —I- - FE DATE 01.15.07 01.15.07 • ISSUE FOR PERMIT SUBTITLE MECHANICAL MASTER COFFMAN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 SECOND FLOOR PLUMBING PLAN 9--90 RENOVATION LEGE BUILDING 9 -90,1 COL. F— L/1 -13 DEV. CENTER,WA \D A COMPRESSED AIR, PLANT CW DOMESTIC COLD WATER ----- HW HWC PW PROCESS WATER icfI DOMESTIC HOT WATER SUPPLY DOMESTIC HOT WATER CIRCULATING BUTTERFLY VALVE 0 VENT THROUGH ROOF WATER HAMMER ARRESTOR BALL VALVE, OPEN 0 -- PIPE ELBOW, TURNED UP OR TOWARD �—E--. PIPE ELBOW TURNED DOWN OR AWAY GENERAL OTES REFERENCE DRAWINGS CONNECT STANDPIPE DRAIN AND VENT TO SINK WASTE ROUGH —IN. CODE COWILIOCZ F \ Ikt\`( 2 i CONSTRUCTION NOTES C D 0 2M110 2M112 2M113 8' SHEET JOB NO. DWG No. 4' 0 4' SCALE: 1/8"=1'-0" CURRENT REVISION 2M111 150680 -01 8' sYm " L ORIG 9- 90- -2M111 DATE COMP NO. (RECEIVED TTJIrML4 APR 0 9 2007 P.iS IT CE,s,i 16' 04.05.07 r CI 7 C I 9 -90 RENOVATION REVISION EC 1 4" _.O.r= _r HUDDLE UP TO RD 4150680-01 OFFICE 23L10 OFFICE 22L10 WORK ROOM 2 II_1U OPEN OFFICE BY COFFMAN 21M8 OPEN OFFICE 21S8 APPROVED M. SOTURA DATE _r .._.M.. __■RE_n _rwr ∎Mw r.1 w_ _w _. RR RR __ rwrr=1 _ _ww+_w_r 04.05.07 SYM OFFICE 23L9 OFFICE 4" 22L9 CONFE R � 21L9 P TO RD� REVISION >a 5- (EE 2 "V DN 2 "V UP CONF BY APPROVED -- - -- -- DATE ;.\ \ HNCE, 4 "W DN 4" UP TO FD RENCE 4" UP ) TO FD 4" UP TO FD 2 "V UP V 3/4 "A 5 "RD 4 "W SECOND FLOOR PLUVIBINC PLAN CONFERENCE 22L51 4' UP TO RD OFFICE 21M4 OFFICE 21 N4 5 " 4" 0)i S Fl N CONFERENCE 21 P3 r- __ _r _..-_- ___.._._...r WORK ROOM 3 "RQ UP I __rr._orrr____r__.wr.w_ r_ J - - - r .w- rrr rti+ -rr,_w _ w rrr-+y r__ OPEN OFFICE 21R5 ACCEPTABILITY THIS DESIGN AND /OR SPECIF1CATION IS APPROVED APPROVED BY DEPT. OPEN OFFICE 21M5 DATE DRAWN COFFMAN CHECKED M. SOTURA ENGINEER CHECKED APPROVED APPROVED RD 4" UP TO RD FEC ISSUE FOR PERMIT DATE 01.15.07 01.15.07 SUBTITLE TITLE MECHANICAL MASTER N OFFMAN 6 1 N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 SECOND FLOOR PLUMBING PLAN 9 -90 RENOVATION BUILDING 9 -90,1 COL. L— S/1 -13 LECE\D A COMPRESSED AIR, PLANT CW DOMESTIC COLD WATER HW DOMESTIC HOT WATER SUPPLY HWC DOMESTIC HOT WATER CIRCULATING PW PROCESS WATER Is�l BUTTERFLY VALVE 0 VENT THROUGH ROOF --1 WATER HAMMER ARRESTOR I �t BALL VALVE, OPEN o;— PIPE ELBOW, TURNED UP OR TOWARD c—I-- PIPE ELBOW TURNED DOWN OR AWAY GENERAL NOTES REFERENCE DRAWINGS o: ; cows 3 44 APPRO 4 2 2*1 DEV. CENTER,WA 8 CONSTRUCTION NOTES © 1O 2M11O 2M113 0 0 KEY PLAN SCALE: NONE 8' 4' 0 4' 8' 16' SCALE: 1/8"--1'-0 CURRENT REVISION SHEET 2M112 JOB Na. 150680 -01 DWG NO. SYMROL R I ^ 9- 90 -2M112 RECEIVED * APR 0 9 2007 DATE 04.05.07 COMP NO. SYM REVISION -- ry.r_r w_ wirrwwwi wr rti _w ___fl_ ww __ HUDDLE 21111 9-90 RENOVATION J #150680 --01 OPEN OFFICE OFFICE 23T10 OFFICE 22T10 BY COFFMAN 21S8 APPROVED M. SOTURA DATE 04.05.07 WORK ROOM 21110 OPEN OFFICE 21U8 S —0— —0— REVISION 4 "RD UP Sc 5 "RD DN 1 1 1 1 22V7 SECOND FLOOR PLU BY JAN. 21U7 STAIR 2M450/2M451 APPROVED CONFERENCE 21V7 3 "RD 2 DATE Ao_ ELEC. 21U6 22U6 CAFE 4 1 'W UP TO FD 2 "V UP --.— r• -- - r - - •, IQI L a ; N r I CONFERENCE 21V6 1 --r 1 vIBING r P AN _r.....• CpNFER 23S ONCE �— 5 » 1-3 UP TO RD �-- 3/4 "A 3 "RD DN 3 "RD UP g) LAMO P AEAVAW ° CONFERENCE 21W5 OFFICE OFFICE 2234 WORK ROOM 2333 T ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. OFFICE 2133 OFFICE 2233 OPEN OFFICE DATE 21T5 DRAWN COFFMAN CHECKED M. SOTURA ENGINEER CHECKED APPROVED APPROVED DATE 01.15.07 01.15.07 SUBTITLE TITLE MECHANICAL MASTER ISSUE FOR PERMIT *OFFMAN 4INFER3 NGINEERS N E E R s 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 SECOND FLOOR PLUMBING PLAN 9-90 RENOVATION BUILDING 9 -90.1 COL. S— Y/1 -13 LEGEND t ``' DEV. CENTER,WA OW CA BU '-311'CI DIVISION CO CURRENT REVISION SHEET JOB NO. DWG NO. KEY PLAN SCALE: NONE 150680 -01 A COMPRESSED AIR, PLANT CW DOMESTIC COLD WATER HW DOMESTIC HOT WATER SUPPLY HWC DOMESTIC HOT WATER CIRCULATING PW PROCESS WATER ICI BUTTERFLY VALVE 0 VENT THROUGH ROOF —o WATER HAMMER ARRESTOR 1 (5 1 BALL VALVE, OPEN 04— PIPE ELBOW, TURNED UP OR TOWARD c—f — PIPE ELBOW TURNED DOWN OR AWAY GENERAL NOTES REFERENCE DRAWINGS STRUCTION 2M170 2M110 2M111 2M113 OTES 9- 90 -2M113 DATE COMP NO. Rip CITY O:TUKWi ' APR 0 9 2007 PER.V.{T GEN T 4F 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" 04.05.07 T, c ; • • ; c i es a SEE UGM3 FOR CONTINUATION 9 -90 RENOVATION REVISION 4 "W 2 "W UP SCALE: I /4 "= j #150680 -01 0 „ BY 2 "V UP 3 "W UP 2 "W UP COFFMAN FCO APPROVED M.SOTURA SEE UGM3 Fo R CONTINUATIO 1 / 2 „ — TP �--- -V 2 "V UP 1 /2 "TP 6 "W DATE 04.05.07 4 "W 6"W SEE GM3 FOR CON INUATION UNDERGROUND TOiLET Roos — WEST UGM3 UGM45O rt SEE UGM3 FOR CONTINUATION DATE SEE UGM3 FOR CONTINUATION I 5 2 "W UP � (CAP AT FLOOR) FCO 2 "V UP 3 "W UP 17 SEE UGM3 FOR CONTINUATION SCALE: 1 /4 "= 1'--0" (CAP AT FLOOR) 2 "V (CAP AT FLOOR) 2 "W 2 "W UP --)) 3" (CAP AT FLOOR) 5" 2 "W UP 1/2 ", TP to 2" W UP "V 2 "V UP 1/2"TP UP 3" (CAP AT FLOOR) ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. i DATE n 3 „ FCO 2 "W UP DRAWN COFFMAN CHECKED M.SOTIIRA ENCINEER CHECKED APPROVED APPROVED (CAP AT FLOOR) ABANDONED WASTE PIPING TP RD UNDERGROUND TOILET ROOM — EAST SEE UGM3 FOR CONTINUATION DATE 01.15.07 01.15.07 (2 UP JT 3" SEE UGM3 FOR _ CONTINUATION UGM3 UGM45D ISSUE FOR PERMIT SUBThLE If MECHANICAL MASTER 6 „ FCO 3 " (CAP AT FLO01 ) of W 2 "V (CAP AT FLOOR lord 1 2"W (CAP AT FLOOR) ( ,, (E) 6" s SEE UGM3 FOR CONTINUATION N OFFMAN G IN E E KS 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 ENLARGED TOILET ROOM DRAINAGE PLANS 9 -90 RENOVATION BUILDING 9 -90.UG PW 0 I(PI CO C OM APPROV L____ WILDING DI\11 10M DEV. CENTER,WA LEGEND CW HW HWC GENERAL NOTES REFERENCE DRAWINGS 4' JOB NO. DWG NO. BUTTERFLY VALVE VENT THROUGH ROOF WATER HAMMER ARRESTOR BALL VALVE, OPEN PIPE ELBOW, TURNED UP OR TOWARD PIPE ELBOW TURNED DOWN OR AWAY DOMESTIC COLD WATER DOMESTIC HOT WATER SUPPLY DOMESTIC HOT WATER CIRCULATING PROCESS WATER CONSTRUCTION NOTES KEY PLAN SCALE: NONE 2' CURRENT REVISION 0 SCALE: 1/4"=1'-0" SHEET UGM450 150680 -01 2' 4' s 'ORIG DATE 9-- 90--- UGM450 mommo env OF "rf APR 0 9 2007 8 COMP NO. 03.30.07 REVISION ORIG 9-90 RENOVATION J #150680 --01 BY COFFMAN APPROVED M.SOTURA DATE ® REVISION 111C. APPROVED 04.05.07 I MIIIIMMIIIIIIMMIIIIIM DATE MN •11111=1•1111=IMINIIME.1111111•1111=11 111.110111111.1111.1.1.1.11.1 11=111111111 MIIIMMIMIIIMIIIIMIIIIMIIIIMINIIIII SEE 1M110 FOR CONTINUATION s---T— 1 /2 "HW & CW TO I FIXTURE 2 "CW UP- 1 "HWUP 3/4" HWC UP COFFEE WATER SUPPLY CONNECTION DN TO P -8 & P--7 P -8 4 JAN. 11E7 P -3 (TYP) WOMEN 111F7 3/4" 1 /2 " P -7 O WATER FILTER IN CASEWOR< ELECT. 12D6 INFRARED POWER TRANSFORMER WI SHUT -OFF SWITCH (120V -10) 1 J 1 /2 "HW & CW TO FIXTURE 1ST FLOOR T SCALE: 1/4' = 1'--0" WATER FILTER &TRAP PRIMER IN WALL CAVITY W/ ACCESS DOOR (WATER COOLER CW) STORAGE 11E6 ILET ROOvi 2-- 1 /2 "CW UP HW II Il 11 11 II MEN 11F6 ACCES DOOR, 14"x14' TO T`.LP PRIMER & R FILTER -- WEST 0 0 0 ,,--1 "HW UP 1 /2 "HW & CW TO FIXTURE rt SEE 1M113 FOR i I CW CONTINUATION .- 1 �H 1 /2 "HW & CW TO FIXTURE SEE 1M113 FOR CONTINUATION S I PW _C �BOE /NG WOMENS MOTHER'S P - 3 1 /2 "HW & CW TO FIXTURE 1/2" 374 ELECT. J L_ HW MENS }1 COFFEE WATER SUPPLY CONNECTION DN TO P -8 & P -7 P-8 1ST FLOOR TOILET ROOM — EAST SCALE: 1/4'= 1'-O" EXPIRES 9/21/07 P -7 r L P 6 1 J WATER FILTER & TRAP PRIMER IN WALL CAVITY W/ ACCESS DOOR (WATER COOLER CW) ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN CHECKED M.SOTURA ENGINEER CHECKED APPROVED APPROVED STOR. 11T6 1 3 /4 "CW UP 2- 1 /2 "CW UP DATE 01.15.07 01.15,07 1 /2 "HW & T CW TO c p 14b FIXTURE 2-1/2" SEE 1M113 FOR CONTINUATION MECHANICAL MASTER 1 "HW UP 2" ISSUE FOR PERMIT ACOFFMAN N 6 IN E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 SUBTITLE ENLARGED TOILET ROOM DOMESTIC WATER PLANS 9-90 RENOVATION BUILDING 9 -90.1 SEE 1M113 FOR PW-- -3 CONTINUATION LEGEND CW DOMESTIC COLD WATER HW DOMESTIC HOT WATER SUPPLY HWC DOMESTIC HOT WATER CIRCULATING PW PROCESS WATER ICI BUTTERFLY VALVE o VENT THROUGH ROOF -U WATER HAMMER ARRESTOR 1 t GEC DEV. CENTER,WA 0-- C-I BALL VALVE, OPEN PIPE ELBOW, TURNED UP OR TOWARD PIPE ELBOW TURNED DOWN OR AWAY ERAL NOTES REFERENCE DRAWINGS R OR CODE g oMPL.I ;NCEE APPROVED WN 2 101 City Of Tukwila CONSTRUCTION NOTES SHEET" KEY PLAN SCALE: NONE 4' 2' CURRENT REVISION JOB NO. DWG NO. 0 2' SCALE: 1/4"= 1 ' 1 M450 4' 150680 -01 9-90-1M450 Cfre APR 0 9 2007 8 DATE 04.05.07 COMP NO. 1 a SYM REVISION BY APPROVED DATE SYM REVISION 81' APPROVED DATE ce 7 ) i . . . 4 6 I � ® ...1 � +d D� 0 4 ' � j i �' � _ .. M + : t. T � r', 1.0- 7 `� � ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN COFFMAN DATE 01,15.07 SUBTIRE ENLARGED TOILET ROOM DRAINAGE PLANS CURRENT REVISION SYMBOL RIG DATE 03.30.07 ORIG 9-90 90 RENOVATION 150680 -01 COFFMAN M.SOTURA 04.05 .d7 CSI ECKED M.SOTURA 01.15.07 SHEET ' ENGINEER THEE MECHANICAL MASTER 9 -90 RENOVATIO RENOVATION n BUILDING 9 -90.1 DEV. CENTER,WA APPROVED BY DEPT. DATE 1 CHECKED JOB NO 150680-01 COMP NO. APPROVED 1auu. I_ IDVRES 9/112107 ' APPROVED DWG NO. 9 --90 -1 M451 11 E7 P -8 WOMEN Te Fa - ABev 2 "FD -11. STORAGE ED ABOVE 1 /2 "TP DN 11 F6 P -2 (TYP) RUN TRAP PRIMER IN PLUMBING CHASE ACCES: DOOR, 14 "x14 TO AP PRIMER & j ER FILTER ( 1-,- SEE 1M111 FOR CONTINUATION 2" 5 V 2 "V UP 2 "W UP & DN Woo (ACCESSIBLE BELOW (COUNTERTOP 2"V UP 3 "W UP 2 "V UP P-7 FCO 2 "W UP r L 1 -1 /2'`W &V HORIZONTAL IN ' WALL ELECT. 1 2D6 3"W DN & 1 -1/2 "W UP 4 "W UP & DN 1ST FLOOR T01 P--6 �.1 LET R00 —MT-ER FILTER &- TRAP - PRIMER IN WALL CAVITY WI ACCESS DOOR — WEST } } 4 "W U f & DN 11 2 "V UP WCo ACCESSIBLE BELOW COUNTERTOP 2 "W UP 2"W DN WCO ACCESSIBLE BELOW COUNTERTOP P -7 r J P-6 MOTHER'S 2"W UP 2 " 2 "FD --1' 1 1/2" 1111 U.P- - 2 "FD-1 1 /2 "TP DN P -2 (TYP) P-3 (TYP) MENS RUN TRAP PRIMER IN PLUMBING CHASE P-2 (H) ACCES: DOOR, 14 "x1 TO '' P PRIMER & ER FILTER 1ST FLOOR TOILET ROOM — EAST SCALE: i /a'= r -o' WATER FILTER & TRAP PRIMER IN WALL CAVITY W/ ACCESS DOOR WCO ACCESSIBLE BELOW COUNTERTOP ISSUE FOR PERMIT 2 "W UP 2 "V UP 2 "W ON ACOFFMAN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 LEGEND V VENT W WASTE TP TRAP PRIMING PIPE PIPE TEE, DOWN O VENT THROUGH ROOF O FCO FLOOR CLEANOUT o1 PIPE ELBOW, TURNED UP OR TOWARD c-- PIPE ELBOW TURNED DOWN OR AWAY -- POINT OF CONNECTION I^1 GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES KEY PLAN SCALE: NONE 4' 2' 0 RED CITY OF TI JK'W!1 A APR 0 9 2007 PaRk:fl 8' .i4" K s u u o 8 "F 9 -90 RENOVATION SEE 1 M 110 & 1M260 FOR CONTINUATION OF PIPING 3 "V UP --� 4 "W DN 1-1/4"C DN TO DRAIN 1"60# MPS 3 "V DN REVISION F EXISTING 8" FIRE SPRINKLER ALARM VALVE 1 -1 /2 "PRV OVER 3 "PRV, SEE 1/M313 3/4" 125# MPC 3 "V DN I J #150680 -01 (E)8 " F SCALE: 1 /2' = 1' -0' 6" HUB DRAIN (E) FLOOR DRAIN MECH. BY 1106 COFFMAN 1ST FLOOR MECH APPROVED M. SOTURA OVER SEE 1/M31 1 ST FLOOR MECH — OTTOM OPENING 4STM V DATE 04.05.07 6 1► BFI D71A SYM 1 06 fli 1M3, 1M11, 1M61 1M452 14x14 SOUNDLINED 4 "LPC -- V TRANSER BOOT, SEE 1/M506 12J6 n 1M3, 1M11, 1M61 1M452 14x12 EXHAUST DUCT REVISION 18x14 BY APPROVED DATE 1" MPS 2--1 /2 "PW 2--1 /2 "CW 3 "V UP 2-1/2" LANDSCAPE DOUBLE CHECK VALVE BPI • 1611: 21ii 1 W6 4)H> cn a UB IN MEC 3/4" 60# MPS TO PUMPS �-- LADDER S PIT L 3 L - 9 J 71 3/4 "A DN TO PIT W /HOSE END VLAVE & DIRT LEG ± 36" ABOVE FLOOR 5" DUCT (20 GA.) DN TO 4' ABOVE PIT FLOOR LEVEL W /MESH SCREEN AT BOTTOM WITH 14"0 EXHAUST DUCT FROM SHAFT ABOVE 6" MPS UP TO 2ND FLOOR WITH NEW SHUTOFF VALVE AND 2" BY -PASS. SEE DETAIL M5D8 6 "STEAM 125# MPS (BELOW SLAB) - 4 1 3 "PUMPED CONDENSED (BELOW SLAB) --' 1 "COMPRESSED AIR (BELOW SLAB) 1ST FLOOR MECH - 11V6 ( SCALE: 1/2"= 1' -0" UGM3, 1M3, 1M13, 1M63 1M452 REPLACE SUMP PUMP 3 "PC 4" WASTE FROM MH #2 EL CCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. 8 "F UP 8 • 16x16 CEILING MOUNTED AUTOMATIC WET FIRE SPRINKLER ALARM VALVE (EXIST) 3/4 "A UP WALL GRILLE 18X16 1 "MPS SUMP PUMP, SEE 4/1M452 PRV-3, SEE DETAIL 2/M509 1 "STM VENT UP TO ROOF 3 "STM VENT UP TO ROOF SUMP PUMP PLAN ref: SCALE: 1/2 "= 1' -0" 1M452 DiiAWN COFFMAN CHECKED M.SOTURA ENGINEER DATE D APPROVED APPROVED 2 "CHECK VALVE 4# LEAD FLASHING 12" ALL AROUND SLEEVE � V— 4"W UU 2 "W (GALV PIPE) IN ZURN Z-195-3 FLASHING SLEEVE ISSUE FOR PERMIT 01.15.07 MECHANICAL MASTER 9 -90 RENOVATION BUILDING 9 -90.1 COFFMAN N G I N E E K S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 DATE SUBTITLE 01 ENLARGED MECHANICAL ROOM PLANS LEGEND A — COMPRESSED AIR. PLANT C — CONDENSATE RETURN (GRAVITY) CW— DOMESTIC COLD WATER — — CW — — DOMESTIC COLD WATER BELOW GRADE F FIRE LINE — F — FIRE LINE, BELOW GRADE OR FLOOR LPC— LOW PRESSURE CONDENSATE MPC MEDIUM PRESSURE CONDENSATE —MPS— MEDIUM PRESSURE STEAM —PC CONDENSATE RETURN (PUMPED) PW — PROCESS WATER V VENT W — WASTE W — — WASTE BELOW GRADE 0 VENT THROUGH ROOF PIPE ELBOW, TURNED UP OR TOWARD c-I- -- PIPE ELBOW TURNED DOWN OR AWAY -- POINT OF CONNECTION 0 -- t RETURN OR EXHAUST AIR FLOW DIRECTION STEAM TRAP Q- BALL VALVE WITH HOSE END r__ VD (VOLUME DAMPER) GENERAL NOTES M> STEAM CONDENSATE EQUIPMENT IS IN A 7' DEEP PIT. PIT IS 67 "x73" WITH A FLOOR GRILLE ON TOP, REFERENCE DRAWINGS UGM3, COMPOSITE UNDERGROUND PLUMBING PLAN 1M3, COMPOSITE FIRST FLOOR PLUMBING PLAN M314, PLUMBING DIAGRAMS 1 M61, FIRST FLOOR HVAC PIPING PLAN 1 M63, FIRST FLOOR HVAC PIPING PLAN CONSTRUCTION NOTES REPLACE FLOW AND TAMPER SWITCHES. CONTRACTOR SHALL INSTALL SWITCHES PROVIDED BY "ADT ". PROVIDE A SHUTOFF VALVE WITH BYPASS FOR THE 6 "MPS RISER. PROVIDE NEW 2-1/2" PUMPED CONDENSATE PIPE CONNECT TO UNDERGROUND 3" PUMPED CONDENSATE PROVIDE STEAM CONDENSATE PUMP PACKAGE PROVIDE NEW 2" CHECK VALVE PROVIDE 1" 60 PSI STEAM PROVIDE STEAM VENT PROVIDE TEMPORARY CONNECTION TO SANITARY SEWER UNTIL WASTE CONNECTION IS COMPLETE, SEE UGM3. INSTALL VD BETWEEN GRILLE AND 5" DUCT DEV. CENTER,WA CURRENT REVISION SHEET © O1 ECCO n a JOB NO. DWG NO. 1 M452 150680 -01 sYmBOLORIG 9-90-1M452 MEWED APR 0 9 2007 DATE 03.30.07 COMP NO. 2-1/2"CW DN :bi 1 1 I I 1 L a P -3 (TYP) WOMEN r 21E6 EXPIRES 9/21/07 DRAWN COFFMAN CHECKED M.SOTURA ENGINEER APPROVED APPROVED 01.15.07 MECHANICAL MASTER 9 -90 RENOVATION BUILDING 9 -902 2M450 150680 -01 9-- 9D -2M450 1/2 & CW TO FIXT1)RE I 2" ! COFFEE WATER SUPPLY CONNECTION DN TO P -8 & P -7 P -8 C P -7 2ND FLOOR T SCALE: 1/4"= 1'--0' WATER Fl LT IN CASEWO P 5 R K' 1' 1 P -6 ELECT. 22D6 ACCESS DOOR, 14 "x14" TO TRAP PRIMER & WATER FILTER WATER FILTER & TRAP PRIMER IN WALL CAVITY W/ ACCESS DOOR (WATER COOLER CW) ILET ROOM - WEST 2M3 2M450 1 "HW DN t ORIG BY APPROVED COFFMAN M.SOTURA 3/4" UP SEE 2M113 FOR CONTINUATION s anit HWC 1 /2 "HW & CW TO FIXTURE P -3 (TYP) WOMEN � P -1 (H) III W 2 -1/2" 2 -1 /2 "CW DN 3 /4 "CW DN ELEC. ACCESS DOOR, 14"x14" TO TRAP PRIMER WATER FILTER - -2 (H) P--3 (TYP 1---1 /2 "CW P — s -- ill II Wa , DN TO P -8 & P -7 P -7 1/2"CW P-6 n a WATER FILTER IN CASEWORK; COFFEE WATEF SUPPLY CONNECTION 2ND FLOOR TOILET ROOM - EAST ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE ISSUE FOR PERMIT CHECKED DATE 01.15.07 WATER FILTER & TRAP PRIMER IN WALL CAVITY W/ ACCESS DOOR (WATER COOLER CW) 1 /2 "HW & CW TO FIXTURE 1 "HW DN 8 SEE 2M113 FOR CONTINUATION ACOFF MAN NG1NEERS 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 SUBTITLE ENLARGED TOILET ROOM DOMESTIC WATER PLANS LEGEI\ D A CW HW HWC GENERAL NOTES REFERENCE DRAWINGS cove 7'1'1'est,IN-,;C,,a \ APPR vi\rsi COMPRESSED AIR, PLANT DOMESTIC COLD WATER DOMESTIC HOT WATER SUPPLY DOMESTIC HOT WATER CIRCULATING BALL VALVE, OPEN WATER SHOCK ARRESTOR VENT THROUGH ROOF PIPE ELBOW, TURNED UP OR TOWARD PIPE ELBOW TURNED DOWN OR AWAY CONSTRUCTION COTES KEY PLAN SCALE: NONE 4 ' 2' CURRENT REVISION 0 SCALE: 1 /4 " =1' -0" SY4BOL0 R I G Wr�`Y nnA APR 0 9 2007 .I , DATE 04.05.07 : � . I • If 11 1 { Ii r Iri { I III{ •1 C U C C C 2 "V DN 1 DI I ! WCO / ACCElSIBLE BELOW COUNTERTOP 2 "W & 1-1/2 HORIZONTAL IN WALL 1 1/2 "W, HORIZONTAL IN WALL P -2 (TYP) 1 /2 "TP DN 2" FD -1 ELECT. r" f r s1_ WOMEN 2 "V DN 2 " P -8 2 )i A J R 9 -90 RENOVATION REVISION BY APPROVED J #150680 -01 COFFMAN M.SOTURA 04.05.07 21D7 2 "V DN P -4 SHW 21F7 — r SCALE: 1 /4 "= 1' -0" L I - 1 P -5 2VD FLOOR TC J 3 "V UP P -6 > 4 "W DN SHW 21F6 P -4 SEE 2M111 FOR CONTINUATION ILET ROOM - WEST E --���- 4 "W )) 2 "V DN 4 "W DN WCO; ACCESSIBLE BELOW COUNTERTOP DATE WCO ACCESSIBLE BELOW COUNTERTOP 1-1/2" ) 2 "W DN ce; i_AmerksrAw ° WOMEN P -2(H) 3 "V DN 3 "VTR 21(.16 ACCESS DOOR, \ 14 "x 14" TO TRAP PRIMER WATER FILTER J L P -2 (H) RUN TRAP PRIMER IN PLUMBING CHASE P -2 Y ') 1 /2 "TP DN 2 "FD -1 1- -1/2 "V HORIZONTAL IN WALL FIREs 9/21/07 APPROVED BY P -6 r -- P -7 DEPT. J ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DATE 2ND FLOOR TOILET R00 SCALE: 1/4"= 1' -0" \ A DRAWN COFFMAN CHECKED M.SOTtJRA ENGINEER CHECKED APPROVED APPROVED WATER FILTER & TRAP PRIMER IN WALL CAVITY W/ ACCESS DOOR (WATER COOLER CW) - EAST 01 15.07 01.15.07 SUBTITLE MECHANICAL MASTER WCO ACCESSIBLE BELOW COUNTERTOP —1/2" )) ISSUE FOR PERMIT "W DN 2 "V DN COFFMAN N G IN E E K S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 ENLARGED TOILET ROOM DRAINAGE PLANS 9-90 RENOVATION CP ` ‘St. O'ckAG 'S:\1=20 BUILDING 9 -90.2 LEGE DEV. CENTER,WA \D V VENT W WASTE TP TRAP PRIMING PIPE GE �= PIPE TEE, DOWN O VENT THROUGH ROOF O FCO FLOOR CLEANOUT 01— PIPE ELBOW, TURNED UP OR TOWARD c- I--- PIPE ELBOW TURNED DOWN OR AWAY POINT OF CONNECTION \ERAL REFERENCE DRAWINGS M2B, MECHANICAL SCHEDULES 1M451, ENLARGED TOILET ROOM DRAINAGE PLANS 2M3, COMPOSITE SECOND FLOOR PLUMBING PLAN M313, PLUMBING DIAGRAMS M314, PLUMBING DIAGRAMS CONSTRUCTION NOTES 4' CURRENT REVISION SHEET © O1 O JOB NO. SCALE: 1/4"=1' —0" DWG NO. KEY PLAN 2' SCALE: NONE \JOTES 0 2' 2M451 4 ) 'BRIG 150680 -01 9-90-2M451 DATE COMP NO. ter/ - .. APR 0 9 20 PERVI 8' 04.05.07 !, . I 1 „ .c 2 1 c e C 1 E. C .I 'I i a ` C I c_ . 1 ' 0 ` I 9 -90 RENOVATION REVISION 4150680 -01 APPROVED COMBINATION BALANCING VALVE & SHU -OFF VALVE IN RIS• R M. SOTURA 04.05.07 4" UP TO RD CONNECT AIR TO DRY VALVE REVISION MAIN DISCON *ISA �wnwwura �� 4" UP TO RD _ • — - ii I TLEE 2 "V DN 4 "FD -2 EXPIRES 9/21/07 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DRAWN COFFMAN NECKED M. SOTURA ENGINEER CHECKED APPROVED DATE 01.15.07 01.15.07 SUBTITLE ENLARGED WEST PENTHOUSE PLUMBING PLAN CURRENT REVISION ' R I O SHEET P1M452 JOB NO. 150680 -01 HOSEBIBB f 18 "AFF DRY FIRE SPRINKLER ALARM VALVE WET FIRE RISER EXPANSION TANK 2 "V DN DRAIN 4 "RD DN E 4 "FFD --1 LARGED WEST PENTHOUSE PLUVBING PLAN SCALE: 1 /4 "= 1' -0" DATE p ragArzAf® COMBINATION BALANCING VALVE & SHUT -OFF VALVE IN RISER ISSUE FOR PERMIT APPROVED TITLE MECHANICAL MASTER 9-90 RENOVATION *OF FMAN 41N ff 0.i NGINEERS H E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 BUILDING 9 -90.P1 V LEGS \JD A C cW HW HWC PW RD W 0 0 FCO O GENERAL REFERENCE DRAWINGS j F§�'a3v G COL. F- -K /5 -9 DEV. CENTER,WA HB HOSE BIBB 4' DWG NO. 2' COMPRESSED AIR. PLANT CONDENSATE RETURN (GRAVITY) DOMESTIC COLD WATER DOMESTIC HOT WATER SUPPLY DOMESTIC HOT WATER CIRCULATING PROCESS WATER ROOF DRAIN VENT WASTE VENT THROUGH ROOF FLOOR CLEANOUT FLOOR DRAIN BALL VALVE, OPEN PIPE ELBOW, TURNED UP OR TOWARD PIPE ELBOW TURNED DOWN OR AWAY POINT OF CONNECTION CAP TRAP PRIMER KEY PLAN SCALE: NONE OTES CONSTRUCTION NOTES COORDINATE DRAIN LOCATION TO AVOID BEING IN FRONT OF ACCESS DOOR 13 ' P1M452 0 0 0 0 0 2' SCALE: 1 /4 "- -1' -0" 4 DATE 9-- 90--P1 M452 meat) �rry a rl str APR 0 9 2007 PEs:+.%.'1T 8' COMP NO. 04.05.07 ; I t I I U ,I `a MANN DISCON. WET FIRE SPRINKLER RISER (E)DRY FIRE \ SPRINKLER ALARM VALVE CONNECT AIR TO DRY FIRE SPRINKLER ALARM ASSEMBLY 4" UP TO RD I 5YM OI�IG 9-90 RENOVATION REVISION BY APPROVED J #150680 -01 COFFMAN M. SOTURA DATE 04.05.07 3YM REVISION BY APPROVED DATE 3/4" HOSE END BALL VALVE 3/4 "A DN g 2 "V DN 4 "FFD -1 ENLARGED EAST PENTHOUSE PLUMBING PLAN ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED 3 /4 "CW DN 3/4 "A DN 2 -1 /2 ° VTR ISSUE FOR PERMIT D P!Rcs 9/21/07 APPROVED BY DEPT. DATE CHECKED APPROVED DRAWN COFFMAN C Cr M. SOTURA x. APPROVED DATE 01.15.07 01.15.07 SUBTITLE ENLARGED EAST PENTHOUSE PLUMBING PLAN TITLE MECHANICAL MASTER ACOFFMAN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 9 -90 RENOVATION BUILDING 9 -90.P1 COL. N -T/5 -9 DEV. CENTER,WA LEGEND A C CW HW HWC PW RD GE HB HOSE BIBB P:ii-V COPe M LIA APPRO t� CO� v ;C5 COMPRESSED AIR. PLANT CONDENSATE RETURN (GRAVITY) DOMESTIC COLD WATER DOMESTIC HOT WATER SUPPLY DOMESTIC HOT WATER CIRCULATING PROCESS WATER ROOF DRAIN VENT WASTE VENT THROUGH ROOF FLOOR CLEANOUT FLOOR DRAIN BALL VALVE, OPEN PIPE ELBOW, TURNED UP OR TOWARD PIPE ELBOW TURNED DOWN OR AWAY POINT OF CONNECTION CAP TRAP PRIMER FERAL NOTES REFERENCE DRAWINGS SHEET JOB NO. DWG NO. CONSTRUCTION NOTES COORDINATE DRAIN LOCATION TO AVOID BEING IN FRONT OF ACCESS DOOR 13 O P1M453 KEY PLAN SCALE: NONE SCALE: 1/4"=1'-0" CURRENT REVISION O 0 4' 2' 0 2' 4' 8' P1M453 SYMBOL 150680 -01 9 -90 -P1 M453 COMP NO. RECEIVED APR 0 9 2007 ��:• fT cam ,;_,r, DATE 04.05.07 SYM ORIG 9-90 RENOVATION REVISION 4150680-01 BY COFFMAN APPROVED M. SOTURA DATE 04.05.07 SYM 2"RD-1 2"RD 1 H 4"RD- 1 3"VIR 5 1 1 P.I.••••■•• 2"VIR CHWS CI-IWR 3"VTR OUTSIDE AIR INTAKE WEST 4"RD-1 -t PENTHOUSE ROOF 6" STEAM SAFETY VALVE, REE-F-VENT REVISION 4" STEAM VENT 1 'I I • • COMPOSITE ROOF MECHANICAL PLAN SCALE: 1/16"= 1 BY APPROVED DATE eiLigraterzAw® T T —1 INTAKE EAST OUTSIDE AIR 4"RD:1 PENTHOUSE ROOF 4"RD 1 1 APPROVED BY 3"VIR MECH ROOM EXHAUST FAN T TT 3 D 1 3"VTR (STEAM) 1MR (STEAM) F 4"RD 1 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DEPT. ISSUE FOR PERMIT DATE DRAWN DATE COFFMAN 01.15.07 UREVITED M. SOTURA 01.15.07 ENGINEER CHECKED APPROVED APPROVED 1 SUEMTLE TITLE ,-- BRIDGE TO 9-101 7 1 —H O 3"RD-2, SEE 1M113 FOR PIPE RISER - CANOPY ROOF \Nz (A ‘). 9-90 RENOVATION AFOFFMAN NGINEERS 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 COMPOSITE ROOF MECHANICAL PLAN BUILDING 9-90.RF MECHANICAL MASTER COL. A-Y/1-13 PROVIDE NEW 3" STEAM VENT. EXTEND TO 5 FEET ABOVE ROOF DEV. CENTER,WA LEGEND CHWS _ CHILLED WATER SUPPLY CHWR - CHILLED WATER RETURN LPS - LOW PRESSURE STEAM (15 PSI) X PIPE ANCHOR PIPE GUIDE ROOF DRAIN 0 VENT THRU ROOF GEERAL NOTES REFERENCE DRAWINGS CO \ISTRUCTION NOTES INSTALL NEW ROOF DRAIN PROVIDE NEW STEAM PIPE PROVIDE SUPPORT FOR NEW STEAM PIPE. SEE STRUCTURAL DRAWINGS FOR TYPICAL ATTACHMENT TO STRUCTURE AND ROOF FLASHING DETAIL ON ARCHITECTURE DRAWINGS CLEAN OUTDOOR AIR INTAKE PROVIDE NEW 1" STEAM VENT. EXTEND TO 5" ABOVE ROOF SEE DRAWING P1M450 FOR CONTINUATION PROVIDE PENETRATION THROUGH ROOF FOR STEAM VENT PROVIDE NEW EXHAUST FAN SHEET 0 4 ) :T 14.14RFM3 APR 0 9 2001 CURRENT REVISION K EY PLAN RFM3 DWG NO. SCALE: NONE JOB NO. 150680-01 16' 8' 0 8' 16' 32' SCALE: 1/16"=1'-0" 'ORIG 9-90-RFM3 DATE COMP NO. 04.05.07 Ip 1 II , I. SYM f i 1/2 " "COFFEE L SINK MAKER P-7 P-7 WATER FILTER (TYP) PENTHOUSE 1 /2" SECOND FLOOR FIRST FLOOR TRAP PRIMER (ACCESSIBLE FROM PENTHOUSE FLOOR) TYPICAL HWC P-8 REVISION TO FD'S, DRIP INTO DRAINS DRIP INTO FD W /2" AIR GAP 1-1/2"PRV 65PSI DISCHARGE P -4 C, 1 BY J 3"RPBA 3" FUNNEL WITH DRAIN LINE TO FLOOR DRAIN TP APPROVED TP HW 120V POWER SUPPLY, SEE ELECTRICAL 100--HW - P-5 P45 TRANSFORMER l CCESSIBLE ABOVE CEILING .T III -1/4" DATE SYM 1 1 /4 {- 3/4" cw 2-1/2" 3" 2„ vv 3"PRV 60PSI DISC -IARGE 3" P -4 fi 3/4 I0 IT t CW . HW HOSE END BALL VALVE HWC " ) 1/2" REVISION U 3/4" I `71 111- 0- 0- LAV • , -e, 1 P-7 - COFFEE SINK MAKER LAV P -3 P -3 120V POWER SUPPLY, SEE ELECTRICAL P -8 t+ POWER SHUT -OFF SWITCH, PROVIDE LABEL "TOILET ROOM WATER SHUT-OFF SWITCH FOR CLEANING ". —HW SCALE: NONE EXPANSION TANK CAPACITY TOTAL VOLUME 6.4 GAL. ACCEPT VOLUME 3.2 GAL. ELEVATE FOR FREE e, DRAINAGE OF CONDENSATE HOUSEKEEPING PAD PER STRUCTURAL LAV P--3 CW T 3/4 3/4" BY APPRovED 0 p U WEST CORE PLU I ICI\ 2-1/2 LPS t LPS t p i FAUCET VALVE ORIG +1 I ,I 1t t - , I I V DATE BIN cw cN REMOTE TRANSFORMER FOR SENSOR FAUCETS /FLUSH VALVES cpI It HIGH TEMP. RELIEF VALVE [,_ 2 " LOCKING T HANDLE 0 WC WC WC WC URN WC URN WC URN WC P--1 P -1 P -1 P-1 P-2 P -1 P-2 P -1 P -2 P--1 HW 2 1 /2" CW 3/4 T V TO FFD 2_1/2, �, r l I I I I 1 T CW 1 1 , THERMOSTATIC MIXING VALVE (TYPICAL) G RISER 1 -1/4" 1-1/2" 2 „ CW t _I t LJ 3" 1 1 -1/2" 1 g ) LAsfamstrAw® cr LOW VOLTAGE WIRING TO SENSOR ACCESS CONTROLLERS - 1-1/4" DOOR 1M450, 2M450 M313 T & P RELIEF s 2 " 1't F &T TRAP WC WC WC WC WC URN WC URN WC URN P -1 P--1 P -1 P -1 P--1 P -2 P -1 P-2 P -1 P -2 TP-t HW 1/2" DF P -6 1 — 1/4" LAV P--3 WATER FILTER TRAP PRIMER SLEEVE (TYP) I WATER HAMMER ARRESTOR. LOCATE ACCESSIBLE ABOVE r- CEILING (TYPICAL) SIZE PER PDI STANDARDS SENSOR lc 1 (TYPICAL) 1} U TI LAV P-3 APPROVED BY F ) EJ- ) EF cw LAV WATER FILTER DEPT. LAV FAUCET CONTROLLER (TYP) ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED P -3 P-3 DATE LAV I P -3 HW P -3 1/2" LAV DRAWN COFFMAN CHECKED M.SOTURA ENGINEER CHECKED APPROVED APPROVED i i c4 DATE 01.15.07 01.15.07 loi SINK P -7 La- TIME SUBTITLE MECHANICAL MASTER 3" HW ISSUE FOR PERMIT HWC cw 1 -1/4" FOR CONTINUATION SEE M314 FOR CONTINUATION SEE M314 N OFFMAN G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fox 206 624 3775 PLUMBING DIAGRAM 9 -90 RENOVATION BUILDING 9 -90 DEV. CENTER,WA LEGEND CW HW HWC I(I I%I FD EZI GENERAL NOTES REFERENCE DRAWINGS � CODE t%tl a.V c o m f � -, :ot APPRO 14:1, 2!) 2g1 C9Li CONSTRUCTION NOTES CURRENT REVISION SHEET M313 JOB NO. 150680 -01 DWG NO. DOMESTIC COLD WATER DOMESTIC HOT WATER SUPPLY DOMESTIC HOT WATER CIRCULATING BALL VALVE SOLENOID OPERATED VALVE CHECK VALVE WITH FLOW BUTTERFLY VALVE TRAP PRIMER FLOOR DRAIN AUTOMATIC FLOW CONTROL VALVE sYmBD R I G 9--- 90 -M313 DATE RECENED err' OF TUK -A APR 0 9 2C ? COMP NO. P€flA,IT �; iti �+ 04,05.07 SYM ORIG 9-90 RENOVATION REVISION FOR CONTINUATION SEE 2M3 & M313 FOR CONTINUATION SEE 1 M3 & M313 4150680-01 BY COFFMAN 3/4" 1 /2" 1 APPROVED M. SOTURA .41 HW (—) LAV TRANSFORMER FOR SENSOR + P-7 COFFEE SINK MAK R DATE 04.05.07 EN EN SYM TRAP PRIMER (ACCESSIBLE FROM PENTHOUSE FLOOR, TYP) LAV DRIP INTO FD W/2" AIR GAP (TYP) P-3 P-3 P-3 P-8 j 1 /2" REVISION AN II P-7 SINK t I I CW REMOTE TRANSFORMER FOR SENSOR FAUCETS/FLUSH VALVES 1/2 COFFEE MAKER 4 I P-8 Tr CW 1 Th f r 10#1- CW 3 . — HAI 11W —1/4" 1 /2" 2-1 /2" T----/ - ea 1 /2" — 11 FAUCET VALVES ABOVE CEILING, ACCESSIBLE 1/2 120V POWER SUPPLY, SEE ELECTRICAL II LAV P-4 P-3 POWER SHUT—OFF SWITCH, PROVIDE LABEL "TOILET ROOM WATER SHUT—OFF SWITCH FOR CLEANING". 1" BY I HW 1 /2" -I 3/4" P-3 II 1 - 1 / 4" CW P-3 SCALE: NONE APPROVED HOSE END BALL VALVE i 1 20V POWER SUPPLY, SEE ELECTRICAL DATE LAI LAV P-3 2-1/2" 1 Lim 2-1 /2"----„,_ II II 11 SLEEVE (TYP) HW 1 —1 /2" 2" WC WC WC WC WC URN WC URN WC URN P-1 P-1 P-1 P-1 P-1 P-2 P-1 P-2 P-1 P-2 WATER HAMMER ARRESTOR. LOCATE ACCESSIBLE ABOVE CW 1 /2" , CEILING (TYPICAL) SIZE PER I •— 1 —1 /2" I PDI STANDARDS SENSOR (TYPICAL) 2" CW p r AswAr Afare I' I —1 - 1/4 " A h-- 1 / 2 - E DF P-6 \ TP—t I WC WC WC WC WC URN WC URN WC URN P-1 P-1 P-1 P-1 P-1 P-2 P-1 P-2 P-1 P-2 EAST CORE PLUMBING RISER 1 M450, 2M45,9191 4 TP-1 1/2" HW P-3 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DATE APPROVED BY LAV P-3 P-3 LAV P-3 P-3 P-3 WATER FILTER (TYP) DRAWN COFFMAN CHECKED M.SOTURA ENGINEER PECKED APPROVED APPROVED r 1 /2" DATE 1 01.15.07 01.15.07 Pw TO IRRIGATION SYSTEM, SEE PLANS SUBTITLE PENTHOUSE SECOND FLOOR 2-1/2" 2-1 /2" DOUBLE CHECK VA FIRST FLOOR MECHANICAL MASTER ISSUE FOR PERMIT PLUMBING DIAGRAM 9-90 RENOVATION BUILDING 9-90 AFOFFMAN NG1NEERS 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 LEGEND CW — DOMESTIC COLD WATER GE HW HWC fcI 141 r7r ru,1 I%I 1).4 DEV. CENTER,WA ERAL \1OTES CONSTRUCTION \ CURRENT REVISION SHEET JOB NO. I 50680-01 DWG NO. DOMESTIC HOT WATER SUPPLY DOMESTIC HOT WATER CIRCULATING BALL VALVE, OPEN BALL VALVE, CLOSED SOLENOID OPERATED VALVE CHECK VALVE WITH FLOW BUTTERFLY VALVE, OPEN BUTTERFLY VALVE, CLOSED WYE STRAINER (W/ DRAIN VALVE) 2 WAY CONTROL VALVE GATE VALVE PRESSURE REDUCING VALVE PUMP GUAGE PIPE REDUCER AUTOMATIC FLOW CONTROL VALVE TRAP PRIMER HB HOSE BIBB REFERENCE DRAWINGS M314 SYMBOL R OTES RECEr,":" CriV CI II APR 0 9 2N1 IG PEt rt t DATE 04.05.07 DEPT. 9-90—M31 4 COMP NO. . p 1 ORIG 9-90 RENOVATION J#150680-01 COFFMAN M.SOTURA 04.05.07 DATE SYM REVISION APPROVED DATE SYM REVISION BY APPROVED 6"x8" INCREASER HUB DRAIN DETAIL 1mAL,4507 SCALE: NONE WALL EXIST 1 iz2„cw EL 12.25 •. • 4 SCALE: NONE v . • gL AsrawirAwe 0 BUILDING COL. CAST IRON BAR STRAINER TO FIT I.D. OF HUB- OLYMPIC FOUNDRY CO. SERIES 3340 (OR APPROVED EQUAL) 3/4" 1-1/2" GATE VALVE W/EXT HANDLE & BOX 0 EL 12.25 C 3 • r-• 1 1/2" CAP 3/4"NON-FREEZE BOX HYDRANT, 4 4. • 4 VENT-AS REQUIRED - YPICAL BOX HYDRANT DETAIL ( 3-- UGM3b21507 EMP IRES S 9/21/07 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. ISSUE FOR PERMIT DATE WN COFFMAN CHECKED M.SOTURA ENGINEER CHECKED APPROVED APPROVED DATE 01.15.07 01.15.07 SUBTITLE TITLE PLUG 2"C.I. HUB APPROX INV ELE 11'-O" 2"C.I. RUNNING TRAP - MECHANICAL MASTER 4 SCALE: NONE • A EOFFMAN NGINEEKS 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 PLUMBING DETAILS 9-90 RENOVATION BUILDING 9-90 A 4 DEV. CENTER,WA CURRENT SHEET JOB NO. DWG NO. ( -FIN FLR • •- , . REVISION j . .. 4 : . • ELEVATOR PIT DRAIN DETAIL UGM&,4507 M507 "'ORIG 150680-01 9-90-M507 RectivErl CITY OF TI ' APR 0 9 2007 PERI V,i1 DATE 04.05.07 COMP NO. I T I' I. Fl a C ; C I a'