HomeMy WebLinkAboutPermit PG07-103 - STODDEN RESIDENCESTODDEN RESIDENCE
14430 56 AV S
EXPIRED 11 -04-0
PGO7-103
Parcel No.: 3365900445
Address:
Suite No:
Tenant:
Name:
Address:
DESCRIPTION OF WORK:
REPLACE GAS WATER HEATER
Value of Plumbing /Gas Piping:
Fees Collected:
Plumbing
Bathtub or combination bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic, with independent drain
Drinking fountain or water cooler (per head)
Food -waste grinder, commercial
Floor drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
doc: UPC -10/06
14430 56 AV S TUKW
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
STODDEN RESIDENCE
14430 56 AV S , TUKWILA WA
Owner:
Name: LEE ROBERT M
Address: 2709 185TH AVE E , SUMNER WA
Contact Person:
Name: NANCY STODDEN
Address: 14430 56 AV S , TUKWILA WA
Contractor:
Name: FAST WATER HEAT COMPANY
Address: 12601 132ND AVE NE , KIRKLAND WA
Contractor License No: FASTWWH948BC
PLUMBING /GAS PIPING PERMIT
FIXTURE TYPE AND OUANTITY
* *continued on next page **
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 206 248 -1308
Phone: (425)814 -3124
Expiration Date: 01/03/2008
$0.00 Uniform Plumbing Code Edition: 2003
$88.00 International Fuel Gas Code Edition: 2003
Steven M Mullet, Mayor
Steve Lancaster, Director
PGO7 -103
04/20/2007
10/17/2007
Plumbing (cont.)
0 Building sewer and each trailer park sewer 0
0 Rain water system - per drain (inside bldg) 0
O Water heater and/or vent 1
0 Industrial waste treatment interceptor, including
0 its trap and vent, except for kitchen type
0 grease interceptors 0
O Repair or alteration of water piping and/or water
O treatment equipment 0
O Repair or alteration of drainage or vent piping 0
0 Medical gas piping system serving (1 -5)
0 inlets /outlets for a specific gas 0
0 Medical gas piping (6 +) inlets /outlets 0
0 Gas Piping
0 Gas piping outlets (0 -5) 0
0 Gas piping outlets (6 +) 0
PG07 -103 Printed: 04 -20 -2007
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complied
Print Name:
doc: UPC -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
)*t(A
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the pert ce o o razed zed to sign and obtain this plumbing /gas piping permit.
Signature: Gp - � Date: V - a d d 7
z74 4,7(
Permit Number: PG07 -103
Issue Date: 04/20/2007
Permit Expires On: 10/17/2007
Steven M Mullet, Mayor
Steve Lancaster, Director
Date: � II/0 I a
permit and know the same to be true and correct. All provisions of law and ordinances
r specified herein or not.
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PG07 -103 Printed: 04 -20 -2007
Parcel No.: 3365900445
Address:
Suite No:
Tenant:
14430 56 AV S TUICW
STODDEN RESIDENCE
1: ** *PLUMBING AND GAS PIPING * **
V �.
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
PG07 -103
ISSUED
04/20/2007
04/20/2007
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
S: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
doc: Cond - 10/06
* *continued on next page **
PG07 -103 Printed: 04 -20 -2007
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Signature:
Print Name:
doc: Cond -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Date:
. o 7
PG07 -103 Printed: 04 -20 -2007
CITY OF TUKWILA
Community Development vartment
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htto://www.ci.tukwila.wa.us
Site Address: 14430 56 AVE S
Tenant Name:
Property Owners Name: STODDEN, NANCY
Mailing Address: 14430 56 AVE S
Name: STODDEN, NANCY
Mailing Address:
E -Mail Address:
MB]NG /` GAS PIPING: CO
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
CONTACT PERSON Who do we contact When-Sul-4104d is `ready to be issue
Day Telephone: (206)248 -1308
Company Name: FAST WATER HEATER COMPANY
Mailing Address: 12601 132ND AVE NE
Contact Person: Pamela Hill
E -Mail Address: pamelah @fastwaterheater.com
Contractor Registration Number: FASTWWH948BC
Company Name:
Mailing Address:
Company Name:
Mailing Address:
King Co Assessor's Tax No.: 3365900445
KIRKLAND
Contact Person:
E -Mail Address:
Contact Person:
E -Mail Address:
Piumbing/Gas P mitN0.:
Project No ....:.. .
Suite Number:
New Tenant:
City
Oct: use::
Floor:
(] .... Yes 0 ..No
State
State
Zip
Zip
98034
Zip
365471
City
Fax Number:
WA
City State
Day Telephone: 800 -454 -8955 x 133
Fax Number: 425 814 -9516
Expiration Date: 1/3/2008
ii
All.plans riiust b e vet staatpei by Arelil#ect og
State
Zip
City
Day Telephone:
Fax Number:
CORD. All,:plla s'must be wet.st rop b
State
Zip
City
Day Telephone:
Fax Number:
Page 1 of 2
Fixture.... a
TYp -:
` -Qh'
,Fixtare.. e
'�'F . ; ';:
Qty
Fixture Type: ; :
.`Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Drinking fountain or water
cooler (per head)
Wash fountain
Gas piping outlets
Bidet
Food -waste grinder,
commercial
Receptor, indirect
waste
Clothes washer, domestic
Floor drain
Sinks
Dental unit, cuspidor
Shower, single head trap
Urinals
Dishwasher, domestic,
with independent drain
Lavatory
Water Closet
Building sewer or trailer
park sewer
Rain water system — per
drain (inside building)
Water heater and/or
vent
1
Additional medical gas
inlets/outlets — six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water treating
equipment
Repair or alteration
of drainage or vent
piping
Medical gas piping system
serving one to five
inlets/outlets for specific gas
Valuation of Project (contractor's bid price : $
Scope of Work (please provide detailed information): Remove /Replace Gas Water Heater
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Yalue of Construction — In all cases, a: value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature: ,i�`T i�.ff Date: 4/18/07
Pamela Hill
Print Name:
Mailing Address: 12601 132ND AVE NE
Date Application Accepted:
Date Application Expires: Staff Initials:
1
Q:1AppliniionnWonos•Applladons On LIneU.2006. Ptumbing•Gu Pipleg Permit Appaadnn.doo
Revised: 44006
bh
Day Telephone: 800 -454 -8955 x 133
KIRKLAND WA 98034
City
State
Zip
Page 2 oft
Parcel No.: 3365900445
Address: 14430 56 AV S TUKW
Suite No:
Applicant: STODDEN RESIDENCE
Receipt No.: R07 -00622
Initials: JEM
User1D: 1165
Payee: FWH ACQUISITION COMPANY LLC
ACCOUNT ITEM LIST:
Description
PLUMBING - RES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
TRANSACTION LIST:
Type Method Description Amount
Payment Check 3005 88.00
Account Code Current Pmts
000/322.100 88.00
Total: $88.00
Permit Number: PG07 -103
Status: APPROVED
Applied Date: 04/20/2007
Issue Date:
Payment Amount: $88.00
Payment Date: 04/20/2007 09:49 AM
Balance: $0.00
7325 04/20 9716 TOTAL 88.00
dnr.• Rer .int -fl Printed! 04-90 -2087
Project.
/2, (l % / 4
Type o f c
�
'o?, . h - . % zi
Address: 2 e 5 "/t s'
Date Called:
Special Instructions:
_
Date Wanted: a.m.
/ 0 / 12/0 -7 S
Requester:
Phone No:
2 53 " C/7 D
INSPECTION RECORD
Retain a copy with permit / 6 7 " \)'‘,
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION V.
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
El Approved per applicable codes. % E.Corrections required prior to approval.
COMMENTS:
N / (r , S_ i A/O / 1 i /t
S/? 4 et( K- A( 7,s
L ( 40 d it/4.-1
Date:
i� / /r
.00 REINSPECTION FE REQUIR . Prior to inspection, fee must be
aid at 6300 Southcenter Blvd., S ite 100. Call the schedule reinspection.
'Receipt No.:
'Date:
Project:
.. - 7 — )Fiv
�r_S.
Type of Inspection:
/=7A. Ai /
Address:
/S' 43d 5
/770 s
+� `"
Date Called: °`
Special Instructions:
Date Wanted: ✓
5 -- 6 O -'
a.
p.m.
Requester:
l
Phone No:
.---
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
COMMENTS:
131 5,0 t se78
4,6 //
�►n/J lve 4
h L.�
e. , / S -Ci 1?
Approved per applicable codes.
El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
'Receipt No.:
Date:
Corrections required prior to approval,
DESCRIPTION
T
y
p GAL.
E CAP MODEL NUMBER
GAS SPAT
THOUS.
NAT.
FEATURES
IN RECOVERY
BTU'HR ' G H.90
LP . NAT.
IN
RISE
; LP
FIRST HOUR
DEL. E.P.A.
I NAT.
ROUGHING IN DIMENSIONS (SHOWN IN INCHES)
ROTS WATER NT.TO
HT TO . TANK GAS VENT CONN. SIDE WATER SHIP.
VENT I HT DIAM. CONN. SIZE CNTR. TOP CONN. WT.
A I B , C D E F I G H (1.85)
ENERGY
ENERGY
FACTOR
NAT.
INFO.
AVG. ANN.
OPER. COST
NAT.
40 42VR40-40F
40 34 40.4 34.3
68
63.1/4 59-3/4 21 14-1/2
3
8 53.12
3/4
135
0.62 ' $220
I T^LL ' 50 142VR50•40F
40 I 36 40.4 36.4
83
62-1/4 1 58.3/41 23 14-1/2
3 i
8 152.12
3/4
165
0.62 ! $220
30 i 22V30-30F
30 I 27 • 30.3 27.3
53
60.114 i 57 17 -3/4 14 -12
3 ;
8 ' 51 -1/4
i 3/4 101
0.62 ; $224
38
: 42V40F
40 ' 40.4 1 34.3
, 68
61-1/2 : 57-3/4
1 19.3/4 14 -12
3
8 52-1/44
3/4 125
0.60 $227
T 40
22V40.36F1
36
- ' 36.4 I -
67
61-1/2 58
17-3/4 f 14-1/2
3 •
8 t 53
3/4 I 120
0.59 $231
L 40
22V40F1
38
- 1 38.4 -
1 73
61.34 5838 181/8 14-1/2
3
8
52.1/4
3/4
120
0.59 $231
-4--- 50
22V50F1
38 1..
- 38
- i
90
61-1/2 158 -1/4 , 20.1/8 14 -1/2 1
3
8
51-3/8
3/4
130
0.58 ' $235
50 42V50-40F
40
36 40.4
36.4
83
61-1/2 1 58 1 21.314114 -12
3 '
8
52-1/2
l 3/4
150
0.58
$235
50
42V50 50F
50
f - 1 50.5
-
83
62 158
21-3/4 14-1/2
4 !
8
52-1/2
3/4
150
0.58
$235
N i . 30
22V30S-30F
30
- 1 30.3
-
50
49.3/41 46-1/4
19 -3/4
14-1/2
3 1
8
40-1/4
3/4
98
0.61
$224 !
& i 40
42V40s -40F
40
r
36 1 40.4
36.4
70
53 4942
21 -3/4
14-1/2
3 1
8
44
3/4
133
0.59
$231
' 50 42V50S -40F
40
36 i 40.4
36.4
72
53-3/4 t 49-3/4
23-3/4
14-1/2
3 I
8
44
3/4
158
0.58 $235
Fury® Gas Water Heaters Rheem
Get
4 MORE YEARS
with ProtectionPlus'
SPECIFY LP GAS WHEN ORDERING. Add "P suffix o the model number: Example: 42VR40 -40PF.
For high altitude applications of 6,000 to 10,000 feet above sea level, add "H" suffix to the model number Example: 42VR50 -40HF (available in 40 and 50 gallon models).
Rheem Guardian System Features...
Exclusive Combustion
Shut -off System
Should a spill incident occur, the
Guardian System shuts off the gas
supply and the air supply preventing
a sustained vapor burn in the
combustion chamber.
These units are designed to meet or exceed ANSI
(American National Standards Institute) requirements and
have been tested according to D.O.E. test procedures and
meet or exceed the energy efficiency requirements of
NAECA, ASHRAE standard 90, ICC Code and all state
energy efficiency performance criteria for energy
consuming appliances.
Available in 30, 38, 40 and 50 Gallon Tall - 30, 40 and 50 Gallon Short Gas Models
/ 6 -Year Limited Tank and Parts Warranty*
/ With ProtectionPlus'" the 6 - Year Limited Tank Warranty Becomes 10 Years!
Guardian System'"
• One -of -a -kind air /fuel shut -off device offers double
protection
• Maintenance free - no filter to clean
• Standard replacement parts
Environmentally Friendly Burner
• Low NOx design for low nitrous oxide emissions
Self- Cleaning
• EverKleen° patented system fights sediment build -up.
• Reduces fuel costs
• Provides more hot water
Easy to Light
• No matches required
Energy Efficient
• More hot water at low operating cost
High Altitude Compliant
• All models are certified for applications up to
6,000 feet above sea level
Before purchasing this appliance, read important energy
cost and efficiency information available from your supplier.
Flame Arrestor Plate
A specially - designed flame arrestor
prevents ignition of vapors outside the
combustion chamber.
PRINTED IN U.S.A 04/05 WP
Maintenance Free
Superior air filtration prevents the
flame arrestor from becoming clogged
by lint, dust and oil.
For more details, see form 101 -7.
PROTECTION T°
6 YEAR LIMITED
TANK WARRANTY
BECOME
Rheem Water Heaters • 101 Bell Road, Montgomery, Alabama 36117 -4305 • www.rheem.com
Longer Life
• Patented magnesium anode rod design
incorporates a special resistor that protects the
tank from rust
Plus...
• Brass drain valve and temperature and pressure
relief valve are included
• Meets or exceeds National Appliance Energy
Conservation Act (NAECA) requirements
High Efficiency Models Feature:
• High performance and lower operating cost
• Compliant with many gas utility incentive
programs
'See Residential Warranty Information Brochure
for complete warranty information.
Energy Factor and Average Annual Operatin
Costs based on D.O.E. (Department of E
lest procedures. D.O.E. national average
rate natural gas 91e/therm: LP 61.23/gal
H
HOT
WATER
CONNECTION
I
A l
FLUE
ANODE ROD
3/4" N.P.T.
REUEF
VALVE
OPENING
H
COLD
WATER
CONNECTION
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
FORM NO. 101 -6 Rev 7
10 -02 -2007
NANCY STODDEN
14430 56 AV S
TUKWILA WA 98188
RE: Permit No. PG07 -103
14430 56 AV S TUKW
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the Uniform Plumbing Code and/or. International Fuel Gas Code, every permit issued by the Building Division under the
provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Plumbing and/or Gas Code does allow the Building Official to approve one extension of time for an
additional period not exceeding 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances
beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 11/04/2007 , your permit will become null and
void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
er Marshall,
Permit Technician
xc: Permit File No. PG07 -103
city of Tukwila
Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
6300 Southcenter Boulevard. Suite #100 • Tukwila. Washin.eton 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
License Information
License
FASTWWH948BC
Licensee Name
FAST WATER HEATER COMPANY
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
602564544
Ind. Ins. Account Id
5380601
Business Type
LIMITED LIABILITY COMPANY
Address 1
12601 132ND AVE NE
Address 2
City
KIRKLAND
County
KING
State
WA
Zip
98034
Phone
4258143124
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
1/3/2006
Expiration Date
1/3/2008
Suspend Date
Separation Date
Parent Company
FWH ACQUISITION COMPANY LLC
Previous License
FASTWHCO52DF
Next License
Associated License
Business Owner Information
Name
Role
Effective
Date
Expiration
Date
JORDAN, JEFF
PARTNER/MEMBER
01/03/2006
HANLEYBROWN,
JASON
PARTNER/MEMBER
01/03/2006
Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
DEVELOPERS
https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= FASTWWH948BC 04/20/2007