HomeMy WebLinkAboutPermit PG07-105 - DOAK HOMESDOAK HOMES
1165335LNS
CANCELLED 05 -29 -07
PGO7-1O5
Parcel No.:
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name: MONARCH PLUMBING
Address: 2415 INTER AV , PUYALLUP WA
Contractor License No: MONARP *062D8
DESCRIPTION OF WORK:
RENEWAL OF PG06 -095: PLUMBING FOR NEW SFR (GROUNDWORK APPROVED UNDER OLD PERMIT)
Value of Plumbing /Gas Piping:
Fees Collected:
doc: UPC - 10/06
0733000034
11653 35 LN S TUKW
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
DOAK HOMES
1165335LNS, TUKWILAWA
DOAK HOMES INC
1181226 AV SW,BURIENWA
PHIL OR STEVE
2415 INTER AV , PUYALLUP WA
$5,800.00
$116.00
Plumbing
Bathtub or combination bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic, with independent drain
Drinking fountain or water cooler (per head)
Food -waste grinder, commercial
Floor drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
PLUMBING /GAS PIPING PERMIT
FIXTURE TYPE AND OUANTITY
* *continued on next page **
Permit Number:
Lssue Date:
Permit Expires On:
Phone:
Phone: 253 770 -2400
Phone: 253 770 -2400
Expiration Date: 03/23/2009
Uniform Plumbing Code Edition: 2003
International Fuel Gas Code Edition: 2003
Steven M Mullet, Mayor
Steve Lancaster, Director
PG07 -105
04/25/2007
10/22/2007
Plumbing (cont.)
3 Building sewer and each trailer park sewer 1
0 Rain water system - per drain (inside bldg) 0
1 Water heater and/or vent 1
0 Industrial waste treatment interceptor, including
1 its trap and vent, except for kitchen type
0 grease interceptors 0
0 Repair or alteration of water piping and/or water
0 treatment equipment 0
0 Repair or alteration of drainage or vent piping 0
3 Medical gas piping system serving (1 -5)
0 inlets /outlets for a specific gas 0
1 Medical gas piping (6 +) inlets /outlets 0
1 Gas Piping
0 Gas piping outlets (0 -5) 0
3 Gas piping outlets (6+) 0
PG07 -105 Printed: 04 -25 -2007
Permit Center Authorized Signature:
I hereby certify that I have read and xawned this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied ri h, whether specified herein or not.
The granting of this permit does not presume to give a thority to violate or cancel the provisions of any other state or local laws regulating
construction o ;/} performance ork. I am autho e • to sign and obtain this plumbing /gas piping permit. 41/0-1
doc: Signature: I —t Q� ( Date: 4l `�✓
doc: UPC -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www. ci. tukwila. wa. us
Permit Number: PG07 -105
Issue Date: 04/25/2007
Permit Expires On: 10/22/2007
Steven M Mullet, Mayor
Steve Lancaster, Director
Date:
0(I lasls�
Print Name: 4C,ive' Mcn "�,
This permit shall become null and void if the work if not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PG07 -105 Printed: 04 -25 -2007
Parcel No.: 0733000034
Address: 11653 35 LN 5 TUKW
Suite No:
Tenant: DOAK HOMES
1: ** *PLUMBING AND GAS PIPING * **
doc: Cond -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
* *continued on next page **
Permit Number:
Status:
Applied Date:
Issue Date:
PG07 -105
ISSUED
04/25/2007
04/25/2007
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fare-resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
PG07 -105 Printed: 04 -25 -2007
doc: Cond -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Date:
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
PG07 -105 Printed: 04 -25 -2007
Site Address:
Tenant Name:
Property Owners Name: 'N
Mailing Address:
E-Mail Address:
Company Name:
Mailing Address:
ARCHITE REG
Company Name:
Mailing Address:
Company Name:
Mailing Address:
CITY OF TUKWILA
Community Developmen 'epartment
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
M/�Gr w_ (�
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
t of r MAlft -li $ l In C
Contact Person: i � I f Oy 9'n}?
E-Mail Address:
Contractor Registration Number:
Contact Person:
E-Mail Address:
Contact Person:
E-Mail Address:
QAAppliatansWPonns- Applications On LineS3 -2006 - Plumbing -Gas Piping Permit Appliation.doc
Revised: 4-2006
bb
n T ;
PIumbing/G° Permit No
Project X10
(Fo r. o arse only) iDc
King Co Assessor's Tax No.: 32 2K X/0"2 4
Suite Number: Floor:
New Tenant: � .... Yes ❑ ..No
City
State
Zip
Name: Phi / w r ? `- / � , Day Telephone: �� Y7L7 24fTl )
Mailing Address: �v/ 1 Y) kV /K lP( /214 � �/j mac 5� "
/' State p'
Fax Number. (�. •L) (SC'
glans nu t bevet stamped ' iy -Ar'cbttect of
State Zip
ay Telep . one: << _ ! 7() —7
Fax Number: -s 7 -r- () -(R,0
Expiration Date: 4 )
State
Zip
city
Day Telephone:
Fax Number.
State
Zip
City
Day Telephone:
Fax Number:
Page 1 of 2
Fixture Type:
t+`ztae
a
Qty ; :.
Fizhre
::Qty
k�atnrpe:
Bathtub or combination
bath/shower
Drinking fountain or water
cooler (per head)
Wash fountain
Gas piping outlets
Bidet
Food -waste grinder,
commercial
Receptor, indirect
waste
Clothes washer, domestic
‘
Floor drain
Sinks
1
Dental unit, cuspidor
Shower, single head trap
0
Urinals
Dishwasher, domestic,
with independent drain
y
Lavatory
12
Water Closet
Building sewer or trailer
park sewer
y
V
Rain water system — per
drain (inside building)
Water heater and/or
vent
Additional medical gas
inlets/outlets — six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water heating
equipment
-
Repair or alteration
of drainage or vent
piping
Medical gas piping system
serving one to five
inlets/outlets for specific gas
Valuation of Project (contractor's bid pO: $ C3 V '
r 9,
j /
Scope of Work (please provide detailed information): t,t) el4 `/N _ iTei •
Building Use (per Int'l Building Code):
Occupancy (per Intl Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be &viewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND E 1 D THIS APPLICATION AND KNOW THE SAME TO $E TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE • WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OW ts' OR�UTH ' r NT: �,{
Signature: / /( 1 Date: ' I lc?
Print Name:
411 i P 11A L i 14
Mailing Address: -1 IiN
Date Application Expires:
f Date Application Accepted:
tcl 4 =t-
QMpplications Penns- Applications On Linee7 -2006 - Plumbing -Gas Piping Permit Application :doe
Revised: 4-2006
bh
ki
Day Telephone:
/9t1 e / t l e (e.p
Staff Initials:
Page 2 of 2
Initials:
User ID:
RECEIPT NO: R07 -00668
lEM
1165
Payee: MONARCH PLUMBING
SET TRANSACTIONS:
Set Member Amount
ACCOUNT ITEM LIST:
Description
PLUMBING - NONRES
PLUMBING - RES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: //www.ci.tukwila.waus
SET RECEIPT
Payment Date: 04/25/2007
Total Payment: 290.00
SET ID: 0425 SET NAME: MONARCH PLUMBING
PG07 -104 116.00
PG07 -105 116.00
PG07 -106 58.00
TOTAL: 290.00
TRANSACTION LIST:
Type Method Description
Amount
Payment Check 6376 290.00
TOTAL: 290.00
Account Code Current Pmts
000/322.100 116.00
000/322.100 174.00
TOTAL: 290.00
7515 04/25 9716 TOTAL 290.00
Proj ct:
�,� y�j�7)
Type of Ins ection:
A h -
, V
Address:
//_J 3SLAI 5
Date Called:
Special Instructions:
Date Wanted:
— ,4 &
(p_ mm .
Requester:
Phone No:
--s -?X -?
D C. -'
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
COMMENTS:
I lnspecto
I Date: 5 p7
Approved per applicable codes. Corrections required prior to approval.
El $58.00 REINSPECTION E REQUII ED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
'Receipt No.:
'Date:
(206)431 -3670
May 29, 2007
To Whom It May Concern: ottry
eoeveo
rULA
MAY 2 9 2007
PERMS tar'
I would like to request a refund of permit charges for the following permits, there was a EFf
misunderstanding between our heating contractor and us regarding who would pull
permits. Now we have 4 lots which have two Gas Piping Permits issued on each lot. The
addresses and permit numbers requested for refund are listed below.
11635 35 Ln S Tukwila Wa 98168 PG07 -128
11641 35 Ln S Tukwila Wa 98168 PG07 -129
11647 35 Ln S Tukwila Wa 98168 PG07 -130
11653 35 Ln S Tukwila Wa 98168 PG07 -131
Thank you very much for your help. P-t. - o
License Information
License
MONARP*062D8
Licensee Name
MONARCH PLUMBING
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
601531614
Ind. Ins. Account Id
#7
Business Type
CORPORATION
Address 1
2415 INTER AVE
Address 2
City
PUYALLUP
County
PIERCE
State
WA
Zip
98372
Phone
2537702400
Status
ACTIVE
Specialty 1
PLUMBING
Specialty 2
AIR HEAT,VENTILATION,EVAPORAT
Effective Date
3/28/1994
Expiration Date
3/23/2009
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
SVEDARSKY, STEVEN M
PRESIDENT
01/01/1980
Bond
Amount
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
#7
WESTERN
SURETY
CO
70247293
03/23/2007
Until
Cancelled
$6,000.00
04/06/2007
AMERICAN
Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= MONARP *062D8 04/25/2007