Loading...
HomeMy WebLinkAboutPermit PG07-110 - KHAN DEVELOPMENTKHAN DEVELOPMENT 13821 MACADAM RD S PGO7-1 10 Parcel No.: 3229200010 Address: Suite No: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 13821 MACADAM RD S TUKW Tenant: Name: KHAN DEVELOPMENT Address: 13821 MACADAM RD S , TUKWILA WA Owner: Name: AIA INTERNATIONAL VENTURES Address: 24719 43RD AVE SOUTH , KENT WA Contact Person: Name: SUKH SANDHU Address: 306 N 1ST , KENT WA Contractor: Name: WILKINS PLUMBING INC Address: PO BOX 24208 , FEDERAL WAY WA Contractor License No: WII,KIPI953DS DESCRIPTION OF WORK: PLUMBING FOR NEW SFR Value of Plumbing /Gas Piping: Fees Collected: Urinals Water Closet doc: UPC -10/06 $6,000.00 $178.00 Plumbing Bathtub or combination bath/shower 1 Bidet 0 Clothes washer, domestic 1 Dental unit, cuspidor 0 Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks PLUMBING /GAS PIPING PERMIT Expiration Date: Uniform Plumbing Code Edition: 2003 International Fuel Gas Code Edition: 2003 FIXTURE TYPE AND OUANTITY * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 766 -9867 Phone: 253 568 -6770 Steven M Mullet, Mayor Steve Lancaster, Director PG07 -110 04/27/2007 10/24/2007 Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 0 Water heater and/or vent 1 Industrial waste treatment interceptor, including 1 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 0 treatment equipment 0 2 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 4 Gas Piping 0 Gas piping outlets (0 -5) 0 0 Gas piping outlets (6 +) 0 PG07 -110 Printed: 04 -27 -2007 Permit Center Authorized Signature: Signature: Print Name: doc: UPC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us � c( iopd9 Permit Number: PG07 -110 Issue Date: 04/27/2007 Permit Expires On: 10/24/2007 Steven M Mullet, Mayor Steve Lancaster, Director Date I hereby certify that I have read and a ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied , whether specified herein or not. The granting of this pe t does of presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the p formanc of work. I am authorized to sign and obtain this plumbing /gas piping permit. Date: PG07 - 110 Printed: 04 -27 -2007 a This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Parcel No.: 3229200010 Address: Suite No: Tenant: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 13821 MACADAM RD S TUKW KHAN DEVELOPMENT 1: ** *PLUMBING AND GAS PIPING * ** PERMIT CONDITIONS 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: PG07 -110 ISSUED 04/26/2007 04/27/2007 PG07 -110 Printed: 04 -27 -2007 Signature: Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of ork. Date: PG07 -110 Printed: 04 -27 -2007 Name: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: E -Mail Address: CITY OF TUKWILA Community Developme ')epartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE .LOCATION Site Address: , N Gc Ora c yr �� Tenant Name: 1.< (■ Y\ Property Owners Name: \< \ s (?t Y\ Mailing Address: ‘ C r` Mailing Address: 3Q lc 1,1 I to'11\4■ty\S - 30 X I 1 no g Contractor Registration Number: t r , ► I L. k► r1 D S R0 Y1 1 \00 ( T – t )G Company Name: 86 ?l 51n G v _C -e ✓1 Mailing Address: ' , ) 7 - 1 A Contact Person: t"i G1/4) 6 YkA 66 PLUMBING / GAS PIPING PERMIT APPLICATION Q:1Applications\Forms- Applications On Line\3 -2006 - Plumbing -Gas Piping Permit Application.doc Revised: 4 -2006 bh S r Plumbing/(' Permit Project No. King Co Assessor's Tax No.: 349 `t 1 2 -'-0Z_0 I O Suite Number: New Tenant: City Day Telephone: City Fax Number: or o ice use onij State Floor: ❑ .... Yes ❑ ..No q.$)s2: 7 Zip CONTACT PERSON -Who do we contact when your permit is ready to be issu IJ CA State Zip PLUMBING / GAS PIPING CONTRACTOR INFORMATION City State (D / � Zi Day Telephone: 3 — ' b Z� — (� T Fax Number: Expiration Date: ARCHITECT OF RECORD All plans must be wet stamped by Architect of Record a CHI\ —ec i qo coe - 6 — 1 0 ' ''-- / O3 City `` -- State Zip Day Telephone: U 7 b d J 0 Fax Number: ENGINEER OF RECORD – All plans must be wet stamped by En gineer of R ecord n C (v E S V'Qh CN 10 019 bS2 City r , State Zi Day Telephone: L ' Fax Number: Page 1 of 2 Valuation of Project (contractor's bid pr( i $ V t Scope of Work (please provide detailed information): Building Use (per Intl Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing Fixture Type: Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Building sewer or trailer park sewer Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Qty 1 Fixture Type: Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Rain water system — per drain (inside building) Repair or alteration of water piping and/or water treating equipment Qty 2 Fixture Typ Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Water heater and/or vent Repair or alteration of drainage or vent piping Fixture Type: Gas piping outlets Additional medical gas inlets/outlets — six or more Medical gas piping system serving one to five inlets/outlets for specific gas Qty Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER HORIZED AGENT: Signature: Print Name: Date Application Accepted: fixtures and/or gas piping outlets being installed and the quantity below: Svc \ �G��ti�C Y� ►� Mailing Address: (S — ea lq 1 g r S 1 oil Date Application Expires: Q:\Applications\Forms- Applications On Line \3- 2006 - Plumbing -Gas Piping Perini Application.doc Revised: 4 -2006 bh Fr-e Sewer: Day Telephone: City VVc t ) ' � Date: \D•' \ ° 7 Gay- - f - f ^cr czct °/5® ,3L State Zip Page 2 of 2 1 RECEIPT NO: R07 -00698 Initials: JEM UserID: 1165 Payee: AIA CONTRACTING INC. SET ID: 0426 SET NAME: KHAN DEVELOPMENT SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //wwv.ci.tukwila.wa.us D07 -148 584.50 M07 -090 146.00 M07 -091 146.00 M07 -092 146.00 PG07 -109 208.00 PG07-110 178.00 PG07 -111 208.00 TOTAL: 1,616.50 TRANSACTION LIST: Type Method Description Payment Check 4137 ACCOUNT ITEM LIST: Description BUILDING INVESTIGATION MECHANICAL - RES PLUMBING - RES STATE BUILDING SURCHARGE SET RECEIPT TOTAL: Payment Date: 04/27/2007 Total Payment: 1,616.50 Amount 1,616.50 1,616.50 Account Code Current Pmts 000/322.800 580.00 000/322.100 438.00 000/322.100 594.00 000/386.904 4.50 TOTAL: 1,616.50 7585 04/27 9716 TOTAL 1616.50 Project: kl4 3 em Type of Inspection: r= I (CP \- Address: I P,7 1 f 0 ell E;) Date Called: Special nstructions: Date Wanted: L/ . CD �a ( 15:m ; Requester: Phone No: yZS- 7696 - 9 - 06 7 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 P667-if 0 PERMIT (206)43 1 -36 Approved per applicable codes. Corrections required prior to approval. COMMENTS: or: ° 1 ► mil/ ri 8.00 REINSPECTION F REQUIRED. t6rior to inspection, fee must be p aid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Rec ipt No.: Date' L �� Date: Project: X /41/(1 /A° a . Type of Inspection: / 7 / Address: ,, /3g2/ /76.16elog1itedof Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone Phone No: INSPEC NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. 'Receipt No.: INSPECTION RECORD Retain a copy with permit 14 Corrections required prior to approval. COMMENTS: /) A r s, /-f /.-ey crAgi --- 4 r S A■J /./ e /AI £ (1/-/ /67 2,Li" ylizze Date:,- $58.O0 REINSPECTIOI FEE REQUIRED. Prior to inspection, fee must be " paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Date: /7 License Information License WILKIPI953DS Licensee Name WILKIN'S PLUMBING INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602480058 Ind. Ins. Account Id VICE PRESIDENT Business Type CORPORATION Address 1 PO BOX 24208 Address 2 City FEDERAL WAY County KING State WA Zip 98093 Phone 2535686770 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/10/2005 Expiration Date 3/10/2009 Suspend Date Separation Date Parent Company Previous License WILKIP*953BC Next License Associated License Business Owner Information Name Role Effective Date Expiration Date WILKIN, JAMES R PRESIDENT 03/10/2005 Bond Amount WILKIN, MARIBEL VICE PRESIDENT 03/10/2005 FS802896 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #2 EMPIRE FIRE & MARINE INS FS802896 12/21/2006 Until Cancelled $12,000.00 12/01/2006 Look Up a Contractor, Electri ' n or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= WILKIPI953DS 04/26/2007