HomeMy WebLinkAboutPermit PG07-111 - KHAN DEVELOPMENTKHAN DEVELOPMENT
13827 MACADAM RD S
PGO7-111
Parcel No.: 1523049149
Address:
Suite No:
Contact Person:
Name: SUKH SANDHU
Address: 306 N 1ST , KENT WA
Contractor:
Name: WILKINS PLUMBING INC
Address: PO BOX 24208 , FEDERAL WAY WA
Contractor License No: WILKIPI953DS
DESCRIPTION OF WORK:
PLUMBING FOR NEW SFR
Value of Plumbing /Gas Piping:
Fees Collected:
doc: UPC -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
13827 MACADAM RD S TUKW
Tenant:
Name: KHAN DEVELOPMENT
Address: 13827 MACADAM RD S , TUKWILA WA
Owner:
Name: AIA INTERNATIONAL VENTURED
Address: 24719 43RD AVE S , KENT WA
$6,000.00
$208.00
plumbing
Bathtub or combination bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic, with independent drain
Drinking fountain or water cooler (per head)
Food -waste grinder, commercial
Floor drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
PLUMBING /GAS PIPING PERMIT
* *continued on next page **
Permit Number:
Issue Date:
Permit Expires On:
Expiration Date:
FIXTURE TYPE AND QUANTITY
Phone:
Phone: 425 766 -9867
Phone: 253 568 -6770
Steven M Mullet, Mayor
Steve Lancaster, Director
PG07 -111
04/27/2007
10/24/2007
Uniform Plumbing Code Edition: 2003
International Fuel Gas Code Edition: 2003
Plumbing (cont.)
1 Building sewer and each trailer park sewer 0
0 Rain water system - per drain (inside bldg) 0
1 Water heater and/or vent 1
0 Industrial waste treatment interceptor, including
1 its trap and vent, except for kitchen type
0 grease interceptors 0
0 Repair or alteration of water piping and/or water
0 treatment equipment 0
2 Repair or alteration of drainage or vent piping 0
3 Medical gas piping system serving (1 -5)
0 inlets /outlets for a specific gas 0
0 Medical gas piping (6 +) inlets /outlets 0
4 Gas Pining
0 Gas piping outlets (0-5) 0
0 Gas piping outlets (6 +) 0
PG07 - 111 Printed: 04 -27 -2007
Permit Center Authorized Signature;
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Permit Number: PGO7 -111
Issue Date: 04/27/2007
Permit Expires On: 10/24/2007
Steven M Mullet, Mayor
Steve Lancaster, Director
Date: Hlatin-
I hereby certify that I have read and x ed this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complie , whether specified herein or not.
The granting of this pe does no presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the perf ` i ce o ork. I am uthorized to sign and obtain this plumbing /gas piping permit.
Signature:
��- /
Date:
Print Name:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: UPC -10/06
PG07 -111 Printed: 04 -27 -2007
Parcel No.: 1523049149
Address:
Suite No:
Tenant:
doc: Cond - 10/06
KHAN DEVELOPMENT
1: ** *PLUMBING AND GAS PIPING * **
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
13827 MACADAM RD S TUKW
PERMIT CONDITIONS
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
* *continued on next page **
Permit Number:
Status:
Applied Date:
Issue Date:
PG07 -111
ISSUED
04/26/2007
04/27/2007
PG07 -111 Printed: 04 -27 -2007
Signature:
Print Name:
doc: Cond -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Wit,+ ��`l _ U ��
l
Date:
)-
PG07 -111 Printed: 04 -27 -2007
Site Address: 3 R 7 IY\ ( C Ci 0 f) r RI)
Tenant Name: < • \ '�
Property Owners Name: )< h Yl
Mailing Address: Sts C. j) ST
Name: ecU Inc t-1
Mailing Address: Lc.) f ,.
E -Mail Address:
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
E -Mail Address:
Company Name: pc, �1 HU J o f .
Mailing Address: 6 , a S -
Contact Person: () A - Ca
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
CITY OF TUKWILA
Community Developme' epartment
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print**
CONTACT PERSON Who do we contact when your permit is ready to be issued
(.1 y\0 k!
i \ sic- 1<'c v\f
PLUMBING / GAS PIPING CONTRACTOR `INFORMATION
LA) �; �,� P1\J,yv \ ham
,k)a (0 5 � � uo,
City
Gr 1 ID -Q
Day Telephone:
Fax Number:
Contractor Registration Number: t,S t 1 Ks; P ' 1 Expiration Date:
n
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
ENGINEER OF RECORD All plans must be wet stamped by Engineer of Record
3 t . y . 1r\cr N `r L
Q:NpplicationsTonns- Applications On Line\3 -2006 - Plumbing -Gas Piping Permit Application.doc
Revised: 4-2006
bh
King Co Assessor's Tax No.: Ka 3 0 1 ( �
Suite Number:
City
Day Telephone:
City
Fax Number:
New Tenant: ❑ .... Yes ❑ ..No
State l7 , — e Zip
cb1s �.�5 e L C �n S
1 Q1 0 SvUk . J _ fre.,t
City State Zip
Day Telephone: U\ 0.6 — G, S L 0 —cm
Fax Number:
S q 30_3 Z.
City State Zip
Day Telephone: k-1 aS ' ' S _2 Z
Fax Number:
■
State
Floor:
State Zip
Cr O\ g395_,
So3Z
Zip
Page 1 of 2
Fixture Type.
Qty ".:
Fixture Type: , , "
Y
. Fixture Type
tZh'
Fixture! Type: !
Qty
Bathtub or combination
bath/shower
I
Drinking fountain or water
cooler (per head)
Wash fountain
Gas piping outlets
Bidet
Food -waste grinder,
commercial
i
Receptor, indirect
waste
Clothes washer, domestic
f
Floor drain
Sinks
U
Dental unit, cuspidor
Shower, single head trap
2_
Urinals
Dishwasher, domestic,
with independent drain
!
Lavatory
Water Closet
Building sewer or trailer
park sewer
Rain water system — per
drain (inside building)
Water heater and/or
vent
1
Additional medical gas
inlets/outlets — six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water treating
equipment
Repair or alteration
of drainage or vent
piping
Medical gas piping system
serving one to five
inlets/outlets for specific gas
Valuation of Project (contractor's bid p: $ 0
Scope of Work (please provide detailed information): /46 "C)3
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
I Date Application Accepted: H
i z
Q:\Applications\Forms- Applications On Line\3 -2006 - Plumbing -Gas Piping Permit Application.doc
Revised: 4 -2006
bh
... -Mug-
Building Use (per Intl Building Code):
Occupancy (per Intl Building Code):
Utility Purveyor: Water: 1 J Sewer: ' G\ V I
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNE R THORIZED AGENT: t
Signature: C -� Date: � 1 ( 5 '
Print Name: Si c C\ \ 9 Day Telephone: J\ v� J �
Mailing Address: 2 6 (o CO
Staff Initials:
City State Zip
Date Application Expires:
C ` ) Page 2 of 2
1
RECEIPT NO: R07 -00698
Initials: JEM
User ID: 1165
Payee: MA CONTRACTING INC.
SET TRANSACTIONS:
Set Member Amount
ACCOUNT ITEM LIST:
Description
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http. //www.ci.tukwila.wa.us
D07 -148 584.50
M07 -090 146.00
M07 -091 146.00
M07 -092 146.00
PG07 -109 208.00
PG07 -110 178.00
PG07 -111 208.00
TOTAL: 1,616.50
BUILDING INVESTIGATION
MECHANICAL - RES
PLUMBING - RES
STATE BUILDING SURCHARGE
SET RECEIPT
Payment Date: 04/27/2007
Total Payment: 1,616.50
SET ID: 0426 SET NAME: KHAN DEVELOPMENT
TRANSACTION LIST:
Type Method Description Amount
Payment Check 4137 1,616.50
TOTAL: 1,616.50
Account Code Current Pmts
000/322.800 580.00
000/322.100 438.00
000/322.100 594.00
000/386.904 4.50
TOTAL: 1,616.50
7585 04/27 9716 TOTAL 1616.50
Project:
V IA 1 t\-) De u
Type of Inspection:
I-- i
\.)
Address:
?-) /11.V 0 Oani
Date Called:
Special Instructions:
Date Wanted:
a.m.
Requester:
Phone No:
L IZ -
INSPECTION RECORD
Retain a copy with permit
PERMI
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6 300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-
q pproved per applicable codes.
COMMENTS:
nspector
/
Receipt No.:
jp,t4.2, Da5e 1f
0 /.00 REINSPECTION EE REQUIRE . Prior to inspection, fee must be
i p‘id at 6300 Southcent r Blvd., Suite 100. Call to sechedule reinspection.
11
Date:
El Corrections required prior to approval.
Project: i
"4 //7//0 —Zie"Ue‘l_
Type of Inspection:
7 /1
v
/
Address:
� 3 2 7 ,,
_
7
D e Called:
S
Special Instructions:
Date Wanted:
a.
Requester:
Phone No:
s ,
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
El Approved per applicable codes.
COMMENTS: / )
S
t, In 7`7 / /
r
$58.00 REINSPECTION Ft REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
Receipt No.:
Date:
• 1:1, 1
•1. •
PTA) T •
,; '1
206)431 -3
O Corrections required prior to approval.
License Information
License
WILKIPI953DS
Licensee Name
WILKIN'S PLUMBING INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
602480058
Ind. Ins. Account Id
VICE PRESIDENT
Business Type
CORPORATION
Address 1
PO BOX 24208
Address 2
City
FEDERAL WAY
County
KING
State
WA
Zip
98093
Phone
2535686770
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
3/10/2005
Expiration Date
3/10/2009
Suspend Date
Separation Date
Parent Company
Previous License
WILKIP*953BC
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
WILKIN, JAMES R
PRESIDENT
03/10/2005
Bond
Amount
WILKIN, MARIBEL
VICE PRESIDENT
03/10/2005
FS802896
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
#2
EMPIRE FIRE
& MARINE
INS
FS802896
12/21/2006
Until
Cancelled
$12,000.00
12/01/2006
Look Up a Contractor, Electri ' n or Plumber License Detail Page 1 of 2
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= WILKIPI953DS 04/26/2007