HomeMy WebLinkAboutPermit PG07-148 - DOAK HOMESDOAK HOMES
11635 35 LN S
PGO7-148
Parcel No.:
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
doc: UPC - 10/06
0733000031 •
11635 35 LN S TUKW
r
City of Tukwila
Contact Person:
Name: JEANNIE STEWART
Address: 9001 PACIFIC AV , TACOMA WA
Contractor:
Name: HERITAGE ENTERPRISES INC
Address: 9001 PACIFIC AVE , TACOMA, WA
Contractor License No: HERITEI13604
Plumbing
Bathtub or combination bath/shower 0
Bidet 0
Clothes washer, domestic 0
Dental unit, cuspidor 0
Dishwasher, domestic, with independent drain 0
Drinking fountain or water cooler (per head) 0
Food -waste grinder, commercial 0
Floor drain 0
Shower, single head trap 0
Lavatory 0
Wash fountain
Receptor, indirect waste 0
Sinks 0
Urinals 0
Water Closet 0
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
DOAK HOMES INC
1181226 AVSW, BURIENWA
DOAK HOME SINC
11812 26 AV SW , BURIEN WA
PLUMBING /GAS PIPING PERMIT
DESCRIPTION OF WORK:
GAS PIPING FOR FURNACE, RANGE, WATER HEATER, AND FIREPLACE OF NEW SFR
FIXTURE TYPE AND QUANTITY
0
* *continued on next page **
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 253- 922 -2211
Phone: 253 -922 -2211
Expiration Date: 10/26/2007
PGO7 -148
05/24/2007
11/20/2007
Value of Plumbing /Gas Piping: $0.00 Uniform Plumbing Code Edition: 2003
Fees Collected: $88.00 International Fuel Gas Code Edition: 2003
Steven M Mullet, Mayor
Steve Lancaster, Director
Plumbing (cont.)
Building sewer and each trailer park sewer 0
Rain water system - per drain (inside bldg) 0
Water heater and/or vent 0
Industrial waste treatment interceptor, including
its trap and vent, except for kitchen type
grease interceptors 0
Repair or alteration of water piping and/or water
treatment equipment 0
Repair or alteration of drainage or vent piping 0
Medical gas piping system serving (1 -5)
inlets /outlets for a specific gas 0
Medical gas piping (6 +) inlets /outlets 0
Gas Piping
Gas piping outlets (0-5) 4
Gas piping outlets (6 +) 0
PG07 -148 Printed: 05-24 -2007
Permit Center Authorized Signature:
Signature:
Print Name:
doc: UPC-10 /06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www. ci. tukwila. wa. us
\\(
\\( - v
L rtk cciA4J,#-
Permit Number: PGO7 -148
Issue Date: 05/24/2007
Permit Expires On: 11/20/2007
Steven M Mullet, Mayor
Steve Lancaster, Director
Date: all _O
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of worker am authorized to sign and obtain this plumbing /gas piping permit.
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PG07 -148 Printed: 05-24 -2007
Parcel No.: 0733000031
Address: 11635 35 LN S TUKW
Suite No:
Tenant: DOAK HOMES INC
1: ** *PLUMBING AND GAS PIPING * **
doc: Cond -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
* *continued on next page **
Permit Number:
Status:
Applied Date:
Issue Date:
PG07 -148
ISSUED
05/24/2007
05/24/2007
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
6: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
PG07 - 148 Printed: 05-24 -2007
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
saw
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Signature:
Print Name:
doc: Cond -10/06
V\t\ \
Date: SIzyl
PG07 -148 Printed: 05-24 -2007
Contact Person:
E -Mail Address:
Contact Person:
E -Mail Address:
Site Address: 1 3
Tenant Name:
Name:
Mailing Address:
E -Mail Address:
CITY OF TUKWIL
Community Developmen epartment
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print* •
Property Owners Name: ti mt vtC•
Mailing Address: l` ?,Q ' 1 J - S V v
CONTACT PERSON - Who d o we contact when your permit is ready to be issued
Contact Person:
E -Mail Address:
Contractor Registration Number:
PLUMBING / GAS PIPING CONTRACTOR INFORMATION
Company Name: n `N 1° 1 rr
Mailing Address: "l I�
JeQn \ S\ UnI
ARCHITECT OF RECORD All plans must be wet stamped by Architect of Record
Company Name:
Mailing Address:
ENGINEER OF RECORD= All plans must be wet stamped by Engineer of Recor
Company Name:
Mailing Address:
Q:\ApplicationsWorms- Applications On Line\3 -2006 - Plumbing -Gas Piping Permit Application.doc
Revised: 4 -2006
bh
Plumbing/Gas
Project No,
King Co Assessor's Tax No.: 01 ?,3 v b a () 5'
S LA-
Suite Number:
New Tenant:
City
Day Telephoner 22 22
TM 0 Ma
City
Fax Number:
Fax Number:
Expiration Date:
State
Tc■ ;e-1 Oct
Floor:
.... Yes ❑ ..No
l
City State
Day Telephone: q 2 221 1
lu (20, 0I
State
State
Zip
Zip
Zip
Zip
City
Day Telephone:
Fax Number:
City
Day Telephone:
Fax Number:
Zip
Page 1 of 2
Fixture Type
Qty ..
,Fixture Type::
Qty
Fixture Type- .:
Qty - °
Fixture :Type.
Qty
Bathtub or combination
bath/shower
Drinking fountain or water
cooler (per head)
Wash fountain
Gas piping outlets ' 0
Bidet
Food -waste grinder,
commercial
Receptor, indirect
waste
Clothes washer, domestic
Floor drain
Sinks
Dental unit, cuspidor
Shower, single head trap
Urinals
Dishwasher, domestic,
with independent drain
Lavatory
Water Closet
Building sewer or trailer
park sewer
Rain water system — per
drain (inside building)
Water heater and/or
vent
Additional medical gas
inlets/outlets — six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water treating
equipment
Repair or alteration
of drainage or vent
piping
Medical gas piping system
serving one to five
inlets/outlets for specific gas
tow
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information
Building Use (per Intl Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING O OR AUTHORIZEP AGENT:
N \ V1- \
Mailing Address: r / L
Signature:
Print Name:
Date Application Expires:
Date Application Accepted:
Q:\Applications\Fonns- Applications On Linel3 -2006 - Plumbing -Gas Piping Permit Application.doc
Revised: 4 -2006
bh
l,Jy •LC PA q
Day Telephone:
City
Date: 5 29 u I
0 1/Z -221
ct
State
Staff Initials:
Zip
Page 2 of 2
Parcel No.: 0733000031 Permit Number: PGO7 -148
Address: 11635 35 LN S TUKW Status: PENDING
Suite No: Applied Date: 05/24/2007
Applicant: DOAK HOMES INC Issue Date:
Receipt No.: R07 -00934
Initials: WER Payment Date: 05/24/2007 10:25 AM
User ID: 1655 Balance: $0.00
Payee: HERITAGE ENTERPRISES INC
ACCOUNT ITEM LIST:
Description
dnr.. Rwroint -CA
GAS - RES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: //www.ci.tukwila.wa.us
RECEIPT
TRANSACTION LIST:
Type Method Description Amount
Payment Check 49678 88.00
Account Code Current Pmts
000/322.100 88.00
Total: $88.00
Payment Amount: $88.00
8593 05/25 9716 TOTAL 352.00
PrintAd: 05-24 -2007
COMMENTS:
(i) i (hi 6 /,.. 4)71,4A/c/ ti-A. (1/&- 1 0 7- /z..._,-)
Address:
1 ( 3
/ 4 " I
. .
Date Called:
:,....
Special Instructions:
\
Date WAnted:
C- 1 — (
7 7 p.m.
Requester:
Project 4 , , _
I j a 0 Q--- 1 .__i__
Type of Inspestion:
, (-- ) ■ 4 r 1 ( - CoAS
Address:
1 ( 3
- 5 L ^-) S
Date Called:
:,....
Special Instructions:
\
Date WAnted:
C- 1 — (
7 7 p.m.
Requester:
Phone No:
(*)----
; - Z.-200
• 4
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 0 .
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670
" Approved per applicable codes.
LJ Corrections required prior to approval.
Da
In ctor:
KAA-vo 1 44
58.00 REINSPE ON FEE/REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter lvd., Suite 100. Call the schedule reinspection.
'Receipt No.:
Date:
License Information
License
HERITEI13604
Licensee Name
HERITAGE ENTERPRISES INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
600638777
Ind. Ins. Account Id
50766200
Business Type
CORPORATION
Address 1
9001 PACIFIC AVE
Address 2
City
TACOMA
County
PIERCE
State
WA
Zip
98444
Phone
2539222211
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
9/24/1987
Expiration Date
10/26/2007
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
BLAKESLEE, JIM N
01/01/1980
BLAKESLEE, JOEL P
01/01/1980
BLAKESLEE, JIM N
01/01/1980
BLAKESLEE, JOEL P
01/01/1980
BLAKESLEE, RAY J
01/01/1980
01/01/1980
POTTER, REBECCA A
01/01/1980
01/01/1980
Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Bond Information
Bond I
httnc• / /fnrtreec wa anv/1ni/hhin /nrintPr acnv9T.irpnce= T3PRTTPT116n4 ns/la /')nn7