Loading...
HomeMy WebLinkAboutPermit PG07-171 - RIVERTON TERRACERIVERTON TERRACE 14410 41 AV S PGO7-1 71 Parcel No.: 0040000205 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: doc: UPC /06 14410 41 AV S TUKW City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RIVERTON TERRACE 14410 41 AV S , TUKWILA WA KING CO HOUSING AUTHORITY 600 ANDOVER PARK W , SEATTLE WA Contact Person: Name: CHRISTINE JOHNSON Address: PO BOX 249 , AUBURN WA Contractor: Name: AUBURN MECHANICAL INC Address: PO BOX 249 , AUBURN, WA Contractor License No: AUBURMI163BA Value of Plumbing /Gas Piping: $149,875.00 Fees Collected: $965.00 plumbing Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic 0 Dental unit, cuspidor 0 Dishwasher, domestic, with independent drain 0 Drinking fountain or water cooler (per head) 0 Food -waste grinder, commercial 0 Floor drain 0 Shower, single head trap 0 Lavatory 55 Wash fountain Receptor, indirect waste 0 Sinks 0 Urinals 0 Water Closet 0 PLUMBING /GAS PIPING PERMIT DESCRIPTION OF WORK: DOMESTIC WATER REPIPE, CHANGING FAUCETS, INSTALLING 6 NEW ROOF DRAINS, GAS PIPING TO AIR HANDLER AND 1 NEW BACKFLOW DEVICE INSIDE THE MECHANICAL ROOM. Uniform Plumbing Code Edition: 2003 International Fuel Gas Code Edition: 2003 FIXTURE TYPE AND OUANTITY 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 838 -9780 Phone: (253)838 -9780 Expiration Date: 09/12/2008 Steven M Mullet, Mayor Steve Lancaster, Director PG07 -171 07/17/2007 01/13/2008 Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 6 Water heater and/or vent 0 Industrial waste treatment interceptor, including its trap and vent, except for kitchen type grease interceptors 0 Repair or alteration of water piping and/or water treatment equipment 1 Repair or alteration of drainage or vent piping 0 Medical gas piping system serving (1 -5) inlets /outlets for a specific gas 0 Medical gas piping (6 +) inlets /outlets 0 Gas Piping Gas piping outlets (0 -5) 1 Gas piping outlets (6 +) 0 PG07 -171 Printed: 07 -17 -2007 Permit Center Authorized Signature: Signature: doc: UPC-10 /06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG07 -1 7 1 Issue Date: 07/17/2007 Permit Expires On: 01/13/2008 Print Name: 1c v u J Steven M Mullet, Mayor Steve Lancaster, Director Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I ant authorized to sign and obtain this plumbing /gas piping permit. Date: 7 -17X7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG07 -171 Printed: 07 -17 -2007 Parcel No.: 0040000205 Address: Suite No: Tenant: doc: Cond -10/06 1441041AVS RIVERTON TERRACE 1: ** *PLUMBING AND GAS PIPING * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 13: * * * * * * * * * * * * * * ** PUBLIC WORKS * * * * * * * * * * * * * * * * * * * * * * * * ** For fue prevention DDCVA installed inside the building refer to permit PWOT -058. * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: PG07 -171 ISSUED 06/19/2007 07/17/2007 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. T: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. PG07 -171 Printed: 07 -17 -2007 Signature: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ss City of Tukwila I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Print Name: doc: Cond -10/06 Date PG07 -171 Printed: 07 -17 -2007 w Company Name: Mailing Address: Site Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tukwila. wa. us Company Name: Mailing Address: Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION 1414to 41 s+ flv€ S Name: e)A ■S+1VI J bVvi/ls hfl Mailing Address: Q. 0 . P)l`)h 21/44 0 1 Contact Person: E -Mail Address: Contact Person: E -Mail Address: Q:\Applications\Porms- Applications On Line\3 -2006 - Permit Application.doc Revised: 4 -2006 bh Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. ¶)((f7_ 1 7 Public Works Permit No. Project No. (For office use only) King Co Assessor's Tax No.: OQ `1 OD n 0 20S Floor: Tenant Name: 1 W* OYl T X r ( New Tenant: ❑ Yes o Property Owners Name: K in g CCU ni *Ong fivitiovtiv Mailing Address: I y t-I I D 41 $1 Vfc, S TU kW L 1 A g City Suite Number: Day Telephone: 14 Uk)v v n Cit Contractor Registration Number: AUI I I(0b5ig Expiration Date: WA CONTACT PERSON 253• V38.g13 b State E -Mail Address: (1 AU Vo n e., aAAO (..) V 1 rri ctn a i1 t va l • W Y •ax Number: GENERAL CONTRACTOR INFORMATION – (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5) ) Company Name: 4\V 1) UY n mt.ALY12Y1“_,� I Mailing Address: P. O - %rot. 2`4 (7 I 4;3101)y 1(1 Cit Contact Person: CIA V i Sil Yt L J 0 In n SD V) Day Telephone: E -Mail Address: Q1n r tS4 1 nt-�4l )bOY h Yfl `c.(k) IC 1 • (14 Number: ` -- wfi c Zip 253 -23g >9780 State ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record State State -4> '(b? Zip 110'? I Zip Zip City Day Telephone: Fax Number: ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Zip City Day Telephone: Fax Number: Page 1 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste 'R.O O Dv a; n (0 Clothes washer, domestic Floor drain Sinks %C w J)F 114. 5 � Dental unit, cuspidor Shower, single head trap Urinals lit (JfI S Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment I Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas Additional medical gas inlets /outlets — six or more PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 - 431 -3670 PLUMBING AND G AS PIPING CONTRACTOR INFORMATION Company Name: Au IOU Y Yl La I Mailing Address: V•0. BOX 24 al Contact Person: l /h t it n� t l n S U l AUhUrn wet 9801 City State Zip Day Telephone: 2-S3 - 838 • 91 0 E -Mail Address: Fax Number: Contractor Registration Number: -P1 J UR-N1 - 1.1 (0 t P7 Expiration Date: ° 1 / 12 / Valuation of Project (contractor's bid price): $ 1 4 9 , 8 O 0 Scope of Work (please provide detailed information): DO rne..Si Welt ti5 i P t , CYian y't Va o dYa s • s b i •l n a i i hand 1n ci I mu) b Uc- - ) L_-- Inkr), r Y1f-tInani ca 1 (nn Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q:\Applications \Forms - Applications On LineV -2006 - Permit Application.doc Revised: 4 -2006 bh Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O OR AUTHORIZED A NT: Signature: t iY V 1/�� &k1 Q /Vu.(A Print Name: OIVA Y I t ' -\ni J oh nsa n Mailing Address: P.D. ?()x 24 Date Application Accepted: (9-(l -07 Date Application Expires: Staff Initials: vA I Q: Wpplications\Forms- Applications On Line'3 -2006 - Permit Application.doc Revised: 4 -2006 bh Date: () 181 0'1 Day Telephone: 25? ' E38 • °) 7 c ftut,hu, n W A cb) City State Zip Page 6 of 6 Parcel No.: 0040000205 Address: 14410 41 AV S TUKW Suite No: Applicant: RIVERTON TERRACE Receipt No.: R07 -01402 Payee: AUBURN MECHANICAL ACCOUNT ITEM LIST: Description GAS - NONRES PLAN CHECK - NONRES PLUMBING - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Initials: BLS Payment Date: 07/17/2007 12:40 PM User ID: ADMIN Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 9325 923.50 Account Code Current Pmts 000/322.100 000/345.830 000/322.100 Permit Number: PG07 -171 Status: APPROVED Applied Date: 06/19/2007 Issue Date: 88.00 137.50 698.00 Total: $923.50 Payment Amount: $923.50 doc: Receiot -06 Printed: 07 -17 -2007 Parcel No.: 0040000205 Address: 14410 41 AV S TUKW Suite No: Applicant: RIVERTON TERRACE Receipt No.: R07 -01172 Payee: AUBURN MECHANICAL ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Permit Number: PG07 -171 Status: PENDING Applied Date: 06/19/2007 Issue Date: Payment Amount: $41.50 Initials: WER Payment Date: 06/19/2007 11:38 AM User ID: 1655 Balance: $236.00 TRANSACTION LIST: Type Method Description Amount Payment Check 9274 41.50 Account Code Current Pmts 000/345.830 41.50 Total: $41.50 9502 06/19 9716 TOTAL 41.50 doc: Receipt -06 Printed: 06-19 -2007 Project:: i L. Type of Inspection: Address nw_ i Date Called: Special Instructions: Date Wanted ` � / m Requester: Phone No: 7y64 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION C- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 OMMENTS: ti Approved per applicable codes. Corrections required prior to approval. Inspector: - 0 (.9 I Date: ll 7 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: COMMENTS: 6,.e. PA (i i �; / ‘4S- Phi / 'Lb i , / m)%1/2( e k - IJZr/ r/t / /', --/e-'5 rp {- 7 // -Ox fr. 6 /!Y„5 1 . :fi( /,/ 1 - 4 P/4i/ I - lh.-11 Date Wanted: ///2 / / � p.m. c Phone No 26‘- - 73 1 )- /3C Proj t: A' /// /a, ,/,',.//:9( Type of Inspection: F/ — /72M1 6— ‘4S- Address: /4,/ WU / �%9v Date Called: Special Instructions: Date Wanted: ///2 / / � p.m. Requester: Phone No 26‘- - 73 1 )- /3C INSPECTION RECORD Retain a copy with permit ,. / 2 6tJ 7- 1 7/ I PECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. !Date 4 r ) .00 REINS PECTI0 FEE I UIRED. Prior to inspection. fee must be aid at 6300 Southcenter B d.. Suite 100. Call the schedule reinspection. Spector: El Corrections required prior to approval. (Receipt No.: 'Date: ..�...�. ,.„, Project. r Type of Inspection' .... 44? .1, 1 as Address: iY Date Called: Special Instructions: Date Wanted a .m 13 • • Requester: Phone No: 2&,....7 INSPECTZINO. CITY OF TUKWILA BUILDING DIVISION INSPECTION RECORD Retain a copy with permit proved per applicable codes. El Corrections required prior to approval. COMMENTS: if:13 -77 0 $58. EINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: IDate: Address: /7y /U y/ s Special Instructions: Type of Inspection; - ( /7 - (lj- Date Called: Date Wanted: a.m. Requester: Phone No: COMMENTS. `, / INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 06)431-36'0 Project: / U/' /' fc) ICJ /(91 /t!iK' 2'U Approved per applicable codes Corrections required prior to approval. .I /it % . In • pec • r: / INSPECTION RECORD Retain a copy with permit 7 ti- 7? /r/‘/ Qom/ 3vz - 3 / - 1/42 - / ✓u'\_ G°' 71I/Ty ✓t Ii -- /L i /ir' Date: 7-3i -(:) —( f,.v/ •7 /P. le 4 CL .00 REINSPECTI0 FEE REQUIRED. Prior to inspection, fee must be aid at 6300 Southcenter Blvd.. Suite 100. Calt the schedule reinspection. 'Receipt No.: 'Date: Proj ct: /,/ ✓r/Id&i fiiYAelf Type of Inspection: /2( /) — i v 4)k/ Address: / yyw // /94; 5 Date Called: Special Instructions: Date Wanted: 7-2G a , c Requester: Phone No: { INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISIO 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: i " IT O. (206)431 -3670 DaX` Z G � REINSPECTION FEE REQUIREo. Prior to inspection, fee must be id at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Project: , iv�fc'�l/ / % �� Type of Inspection: ,,,I �✓' /� / 67)/// - ,;u �l'tk Address: / /` / ` -// i✓ S Date Called: Special Instructions: Date Wanted: 7 - 2 `(- v —7 ra..m . Requester: Phone No 26 — 75'0 & INSPECTION RECORD Retain a copy with permit INSPECT! N NO. CITY O TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 /' lio 2 - PE • • In I" r , I1 (206)431-367 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: p (� /"" =' /6.5 /b& /(,) ?is " gi b I / 3 1 1 — 4'7,9y/V Inspe Date: 7 V_ 57 $56cb0 EINSPECTION FEE REQUIREf . Prior to inspection, fee must be paid 9 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Project: � , / .1(/ 16A) /,i/'/10P Typ of Insp ction: kae,h -�,L, , 1 7 ,,x/, Address: / y 4- /lv 7/r Ha S Date Called: Special Instructions: Date Wanted: - 7-2 3 a') p Re uester: 0 730 -'3 Phone No: INSPECTION RECORD Retain a copy with permit 3 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ❑ Approved per applicable codes. ❑ Corrections required prior to approval. / C9M M ENTS: p / Uti // / 7n G / y /t/ — /19A/JV i l N In'• ector: icetic 0 REINSPECTION FE REQUIR . Prior to inspection. fee must be vd.. Suit 100. Call the schedule reinspection. d at 6300 Southcente eipt No.: 'Date: Datl7 - -7 (206)431 -36 0 Projec . . j le /7& /) /' //,4(r P Type o spection• -- i il 1.1 i t Ad r L / /o Z // e) 5 Date Called: s ( 1r' , Special Instructions: Date anted: /g 0 7 a.m. ., Requester: Phone No: COMMENTS ( � i, I t' 7/ ) /(�7 7a6 / '3 6 ._. - (.) r` � �� 7 1 � - / & -- IA i INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. 0 Corrections required prior to approval. g--o7 REINSPECTION FEt REQUIR Prior to inspection, fee must be at 6300 Southcenter Blvd., Suit 100. Call the schedule reinspection. pt No.: /44 17/ A 1Date: 2 Proj 1 .. .— K / tiev- L1 1 -/ i9 Ad res Special Instructions: 1 T71 Instwion: e 5' / ' 4./ Date Called: Date anted: Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 proved per applicable codes. Corrections required prior to approval. COMMENTS: ; : 4 . //, /05 — f�FNh /7 4 iLj f/. -0/7 4) /S S r /c) b -1/4 / .. J� �* %� � Y 'S f >Lc.- � d ti pe4 ti / %1?- 7il/S I Date 0 REINSPECTION FEE EQUIRED. rior to inspection, fee must be d at 6300 Southcenter Blvd.. Suite 1 O. Call the schedule reinspection. 'Receipt No.: INSPECTION RECORD Retain a copy with permit / Z / //. 2 /() 7 � / - in./ - 4/9, (1(P e��Tiu�tJ C ho -/r, 'Date: 1 1214 WILKINS a Z!RIV. company Model 350ADA Double Check Detector Assembly • (with OS &Y gates) FEATURES Sizes: 0 2 1/2" ❑ 3" 0 4" ❑ 6" 0 8" 0 10" Maximum working water pressure 175 PSI Maximum working water temperature 140 °F Hydrostatic test pressure 350 PSI End connections (Grooved for steel pipe) AWWA C606 (Flanged) ANSI B16.1 OPTIONS Class 125 (Suffixes can be combined) ❑ with flanged end OS & Y gate valves (standard) ❑ L less shut -off valves (grooved body connections) ❑ LM less water meter ❑ with remote reading meter ❑ with gpm meter (standard) O with cu ft/min meter O G with grooved end OS &Ygate valves ❑ FG with flanged inlet gate connection and grooved outlet gate connection ❑ PI - with Post Indicator Gate Valves (4 " -10 ") ❑ BGVIC - with grooved end butterfly valves ACCESSORIES ❑ Repair kit (rubber only) ❑ Thermal expansion tank (Model ❑ OS & Y Gate valve tamper switch (0 O Test Cock Lock (Model TCL24) tin DIMENSIONS & WEIGHTS (do not incl�ide pkgel- . 6 2 (V Page 1 of 2 SPECIFICATION SUBMITTAL SHEET (with BGVIC valves) APPLICATION Designed for installation on potable water connections in fire sprinkler systems to protect against both backsipho- nage and backpressure of polluted water into the potable water supply. Model 350ADA shall provide protection where a potential health hazard does not exist. Incorporates me- tered by -pass to detect leaks and unauthorized water use. STANDARDS COMPLIANCE (4 "- 8" Horz. & Vertical) • ASSE® Listed 1048 AWWA Compliant C510 (with gates only) • CSA® Certified UL® Classified (21/2 " -10 ") PILE copy • C -UL® Classified (2 1/2 " - ). . .. r • FM® Approved, • Approved by the Foundation for Cross Connectio on Control and Hydraulic Research at the Universityof Southern Call)fornia (2 1/2 " -10" except 10" BGVIC) MATERIALS Main valve body Access covers Coatings Internals Fasteners & springs Elastomers MODEL W 350ADA WITHOUT WITH OS &Y WITH OS &Y B LY SIZE GATES GATES (GXF) GATES (G)G) VAL ES (G ) in. mm lbs. kg lbs. kg lbs. kg lbs. kq 2 12 56.2 56.5 55.8 87.6 186 3 4 6 8 10 65 80 100 150 200 250 105 104 91 141 302 355 47.5 47 41.3 64 137 161 207 224 245 377 778 1040 94 101.5 111 171 353.2 472.7 WEIGHT 199 214 219 347 754 918 90.3 97 99.4 158 342.3 416.5 123.8 124.4 123 193 410 52 I ED er s DE CpMpupNCE A ) pppRO OS & • •bon Ci f Tukwila 0 - with I DIN option CORRECTION MODE_ 350ADA SIZE mm h. 2 1/2 3 4 6 8 1 0 65 80 100 150 200 250 A 351/8 36 1/8 38 47 61 5/8 64 5/8 892 918 965 1194 1565 1642 A WITH BUTTERFLY VALVES h mm . 32 1/8 32 5/8 33 1/8 39 7/8 5412 5412 816 829 842 1013 1384 1384 BLESS GATE VALVES in. mm 201/8 20 1/8 197/8 25 7/8 3812 3812 511 511 505 857 978 978 C h. mm 4 1/2 4 1/2 41/2 5 1/2 10 10 114 114 114 140 254 254 7 239.3 TR# ' DIMENSION (approximate) 0 h. mm 9 9 9 10 1/2 12 12 229 229 229 287 305 305 E MY OPEN h. mm 16 3/8 18 7/8 22 3/4 301/8 373/4 45 3/4 416 479 578 765 959 1162 E OS&Y CLOSED in. mm 13 7/8 15 5/8 181/4 23 3/4 29 1/4 35 3/8 352 397 464 603 743 899 E WITH BU I It f-LY VALVES h. mm 8 8 91/8 10 1/8 11 15/16 135/16 203 203 232 257 303 338 F In. mm 6 6 6 7 81/2 812 152 152 152 178 216 216 G In. mm 71/4 7 1/4 8 10 11 12 184 184 203 254 279 305 Ductile Iron ASTM A 536 Grade 4 Ductile Iron ASTM A 536 Grade 4 FDA Approved electrostatic epoxy finish Stainless steel, 300 Series NORYLTM, NSF Listed Stainless Steel, 300 Series EPDM (FDA approved) Buna Nitrile (FDA approved) NORYLTM, NSF Listed A Attention: Model 350ADA (grooved body) and Model 350DA (flange body) have different lay lengths. RECEIVEL JUL -2 2007 (Patent No. 5,913,331) DOCUMENT #: BF- 350ADA F.E113IG . 11/36 Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft /sec 15 ft/sec 2 1/2" 75 112 149 224 3" 115 173 230 346 4" 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 5288 15 10 5 0 0 15 10 5 0 0 TYPICAL INSTALLATION Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Page 2 of 2 FLOW CHARACTERISTICS MODEL 350ADA 2 1/2 ", 3" & 4" (STANDARD & METRIC) FLOW RATES (Vs) 12.6 25.2 200 400 FLOW RATES (GPM) MODEL 350ADA 6 ", 8" & 10 "(STANDARD & METRIC) FLOW RATES (Vs) 63.1 126.2 8 (200mm) 1000 2000 FLOW RATES (GPM) *Rated Flow (Established by approval agencies) CORREG LTR# 10' (250mm) 37.9 600 189.3 3000 PROTECTIVE ENCLOSURE 12' MIN. 30' MAX. DIRECTION OF FLOW 4> MODEL 350ADA (OUTDOOR INSTALLATION) 50.5 104 If 800 O) 69 252.4 104 if Y _ co 69 35 cc co 4000 MODEL 350ADABGVIC (VERTICAL INSTALLATION) SPECIFICATIONS The Double Check Detector Backflow Prevention Assembly shall be ASSE® Listed 1048, and supplied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be Noryln (NSF Listed), the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backflow Prevention Assembly shall be a WILKINS Model 350ADA. WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805 /238 -7100 Fax:805/238 -5766 RECEIVED IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905 /405 -8272 Fax:905/405 -1 j ,9� Product Support Help Line: 1- 877 - BACKFLOW (1- 877 - 222 -5356) • Website: http: //www.zurn.com IJUL -2 2 007 PERMIT CENTER 4 09 -17 -2008 KING CO HOUSING AUTHORITY 600 ANDOVER PARK W SEATTLE WA 98188 RE: Permit No. PG07 -171 RIVERTON TERRACE 14410 41 AV S TUKW Dear Property Owner: Cii of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current records, the above referenced property is due to have an updated test of the backflow prevention assemblies installed therein. The test(s) is intended to determine if the backflow prevention assembly is operating in accordance with the manufacturer's listed standards. See attached list for the assemblies which need updated test. Where the test indicates that an assembly must be replaced, the work must be done by a licensed plumbing contractor in accordance with the requirements of a plumbing permit. A subsequent successful test of the new assembly will be required for final inspection approval of the installation. In accordance with the Tukwila Municipal Code and Uniform Plumbing Code Section 603.3.3, the premises owner is required to have the backflow prevention assembly tested by a Washington State Department of Health certifed backflow assembly tester. A test report(s) is required to be submitted to the City within 30 days of this notice. If all backflow assemblies pass the required test, the next test will be one (1) year from the date of the successful test report. You will be notified when to schedule the next test. Thank you for your cooperation in this matter. Sincerely, 440,60191e Brenda Holt, Permit Coordinator xc: Permit File No. PG07 -171 PG07 -171 Page 1 of 2 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Assembly #1 Type of Assembly: DCVA Manufacturer: WILKINS Model: 350 Size: 2.5 Serial No.: J24149 Date Inspection Due: 07/06/2008 Assembly #4 Type of Assembly: Manufacturer: Model: Size: Serial No.: Date Inspection Due: Assembly #7 Type of Assembly: Manufacturer: Model: Size: Serial No.: Date Inspection Due: 0 0 BACKFLOW ASSEMBLIES THAT REQUIRE TESTING: Assembly #2 Type of Assembly: Manufacturer: Model: Size: Serial No.: Date Inspection Due: Assembly #5 Type of Assembly: Manufacturer: Model: Size: Serial No.: Date Inspection Due: Assembly #8 Type of Assembly: Manufacturer: Model: Size: Serial No.: Date Inspection Due: 0 0 0 Assembly #3 Tylp of Assembly: Manufacturer: Model: Size: Serial No.: Date Inspection Due: Assembly #6 Type of Assembly: Manufacturer: Model: Size: Serial No.: Date Inspection Due: Assembly #9 Type of Assembly: Manufacturer: Model: Size: Serial No.: Date Inspection Due: 0 0 PG07 -171 Page 2 of 2 • June 25, 2007 Christine Johnson PO Box 249 Auburn WA 98071 RE: CORRECTION LETTER #1 Plumbing/Gas Piping Permit Application Number PG07 -171 Riverton Terrace —14410 41 Av S Dear Ms. Schulz: This letter is to inform you of corrections that must be addressed before your plumbing/gas piping permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Public Works Department. At this time the Building Department has no comments. Public Works Department: Joanna Spencer, at 206 431 -2440, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. encl xc: File No. PG07 -171 City of Tukwila P:\Pemtit Center'Correction Letters\2007\PG07 -171 Correction Ltr #1.DOC jem Steven M Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 1) Since this permit include installation of (1) one new backflow device on fire prevention line Public Works needs size, make, model number and a cut sheet for the proposed Reduced Pressure Principle Assembly (RPPA). The Wilkins Model 350A cut sheet you submitted under PW07 -058 permit for underground fire prevention work was incorrect, because it is a Double Check Valve Assembly (DCVA) and a Detector Double Check Valve Assembly (DDCVA) shall be installed instead. Please note that the proposed backflow shall be from Washington State Department of Health Approved Backflow Prevention list. Please include Fire System West sheet 1 of 5 with your revision resubmittal since it covers inside the mechanical room, see attached mark -up. PUBLIC WORKS DEPARTMENT COMMENTS DATE: June 25, 2007 PROJECT: Riverton Terrace Apts PERMIT NO: PG07 -171 PLAN REVIEWER: Contact Joanna Spencer (206) 431 -2440 if you have any questions regarding the following comments. (P:Joanna Comments PG07 -171 04 -04 -2008 CHRISTINE JOHNSON PO BOX 249 AUBURN WA 98071 RE: Permit No. PG07 -171 14410 41 AV S TUKW Dear Permit Holder: city of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Plumbing Code and/or International Fuel Gas Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Plumbing and/or Gas Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be In writine and arovide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 05/24/2008 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, UVl er Marshall, Pe t Technician xc: Permit File No. PG07 -171 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: PG07 -171 DATE: 07 -2 -07 PROJECT NAME: RIVERTON TERRACE SITE ADDRESS: 14410 41 AV S Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: Building Division ❑ P WWps D TERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete TUES/THURS RO1dTING: Please Route Documents/routing slip.doc 2 -28-02 COORD COPY ` PLAN REVIEW /ROUTING SLIP Fire Prevention ❑ Planning Division Structural Incomplete ❑ Structural Review Required Permit Coordinator DUE DATE: 07 -3 -07 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07 -31 -07 Approved El Approved with Conditions N ot Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPARTMENTS: Z 07 Bui s i g Di slop Complete TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2 -28.02 swei:ERMIT COORD COPY' PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG07 -171 DATE: 06 -19 -07 PROJECT NAME: RIVERTON TERRACE SITE ADDRESS: 14410 41 AV S X Original Plan Submittal Response to Incomplete Letter #_ Response to Correction Letter #_ Revision # After Permit Issued Fire Prevention Planning Division Public Works ,t a . Structural ❑ Permit Coordinator r.P DETERMINATION O COMPLETENESS: (Tues., Thurs.) APPROVALS OR CORRECTIONS: Incomplete Not Applicable DUE DATE: 06 -21 -07 Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:_ Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: DiQ.l a - Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW pd Staff Initials: DUE DATE: 07 -19 -07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steven M Mullet, Mayor Steve Lancaster, Director REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ) I11 0 7 Plan Check/Permit Number: PG07 -171 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Riverton Terrace Project Address: 14410 41 Av S Contact Person: C4'w t 5 t - ' n ` _ . b h n S o h \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Phone Number: IS 3 • -910 Summary of Revision: S►bmitil r11 ()VI a Do.) 191c- y - ASS 'e nblm 1✓1Stm- of a ci o v bl� Ch s�c l VaI�� PE-PVT G` ENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date o revision - Received at the City of Tukwila Permit Center by: ❑ Entered in Permits Plus on )- -07 RECEIVED CITY OF TUKWIIA JUL 2 2007 License Information License AUBURMI163BA Licensee Name AUBURN MECHANICAL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600074968 Ind. Ins. Account Id 20423000 Business Type CORPORATION Address 1 PO BOX 249 Address 2 City AUBURN County KING State WA Zip 98071 Phone 2538389780 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/1/1984 Expiration Date 9/12/2008 Suspend Date Separation Date Parent Company Previous License AUBURMI184LA Next License Associated License Business Owner Information Name Role Effective Date Expiration Date THODAY, DAVID V Cancel Date 01/01/1980 Bond Amount THODAY, STACY A #3 01/01/1980 LPM8047218 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #3 FIDELITY & DEPOSIT CO OF MD LPM8047218 09/01/2001 Until Cancelled $12,000.00 09/12/2001 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3 Saw Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= AUBURMI163BA 07/16/2007 MECHANICAL LEGEND SYMBOL DESCRIPTION MODEL LOCATION AREA SERVED DOMESTIC COLD WATER (CW) COOLING CAPACITY • HEATING `�'" - SUPPLY DUCT UP a"...------t .WEIGHT HP � 2..----.--e DOMESTIC HOT WATER (HW) STARTER FURN. BY ti DUCT SMOKE E N DETECTOR SUPPLY DUCT DOWN EWB EAT DOMESTIC HOT WATER CIRCULATING (HWC) 0 E 80' F ECONOMIZER TOTAL RETURN, RELIEF, TRANSFER, OSA DUCT UP ? • - ---• KW CFM SOIL, WASTE (9, •W) MCA , VOLTS RETURN, RELIEF, TRANSFER, OSA DUCT DOWN PTAC --1 27"" VENT (V), OR HIDDEN BELOW WASTE OFFICE OFFICE 12.0 EXHAUST DUCT UP S5 Z--- E ---- EXISTING PIPING 100% f 85 EXHAUST DUCT DOWN 2-- -G ---- -t NATURAL GAS PIPING 70 RECTANGULAR DUCT SQUARE ELBOW UP - - 95 ri .i. PIPE DOWN 208 RECTANGULAR DUCT, RADIUS ELBOW UP MFR - - Q PIPE UP L RECTANGULAR DUCT, SQUARE ELBOW DOWN 0 WASTE UP RECTANGULAR DUCT, RADIUS ELBOW DOWN n WALL CLEANOUT ROUND DUCT ELBOW DOWN I! 0--t FLUSH CLEANOUT (FCO /SCO) O ROUND DUCT ELBOW UP IF CLEAN OUT (CO) ® CEILING AER TERMINAL - SQUARE 0 IN LINE WASTE CONNECTION 1 ----do- 30t} CFM AIR TERMINAL SIZE, TYPE & CFM R P -TRAP VOLUME DAMPER (VD) TEE PIPE DOWN AFF ABOVE FINISHED FLOOR ICI t TEE PIPE UP BEF BELOW FINISHED FLOOR Z---1.01 t IMF- TEE DOWN AND OUT POC POINT OF CONNECTION TEE UP AND OUT MC MECHANICAL CONTRACTOR t—I3I t TEE DOWN EC ELECTRICAL CONTRACTOR t--- - IT�+I — z TEE GC • GENERAL CONTRACTOR I ITI 2 ..t 1 ELBOWS, 45' & 90' -EX- GATE VALVE (GV) E--7 PIPE CAP -•COQ- GLOBE VALVE 2—•--4 PIPE CONTINUATION �.1- CHECK VALVE (CV) ARROW SHOWN IN DIRECTION OF FLOW PUMP TEMP./PRESS. RELIEF VALVE (T &PRV) -- WALL HYDRANT • -DJ BALL VALVE + I STRAINER CP PRESSURE REDUCING VALVE grurDIR ,....,... ... DRAIN VALVE a f4 -11 UNION — f V THERMOMETER FLOW DIRECTION 4' PRESSURE GAGE TRAP PRIMER WITH ACCESS PANEL iii FLEXIBLE PIPE CONNECTION FLOOR DRAIN 0 CROSSING LINES, NON CONNECTIONING t PACKAGED TERMINAL AIR CONDITIONER SCHEDULE UNIT N4 MFR. MODEL LOCATION AREA SERVED EER COOLING CAPACITY • HEATING `�'" - B " -- EX [N. WC) -- RPM .WEIGHT HP � (IDs) ELECTRICAL STARTER FURN. BY DISCONNECT FURN, BY DUCT SMOKE E N DETECTOR EWB EAT T BTU L .. .. 0 E 80' F ECONOMIZER TOTAL EAT AMPS KW CFM OSA MCA MOP VOLTS PTAC --1 —ww�r =M. i TRANS" PTEEEO701 UA OFFICE OFFICE 12.0 67 S5 7000 24 100% 5500 85 7.9 1.6 225 70 0.3 - - 95 11,1 i 15 208 3 MFR EC - GO • • SYMBOL • MOUNTING '• F O R M A N C E • •PANA$ON1C ' . fV05VF1 " Mi' . CEILING lall•PANASON.IC F c a t Sff CEILING. 1Q0, PAN4SONIC FU71VF2 . .' NAJMi' ROOM 1E= ,10 I1 000 1.8 NA N0: SWITCH 0.28 120 � Q REMARKS UNIT , 'Nib, - REZNOR MODEL.- FIXTURE: MISTING TO ; PRICE PFISTE PR 1 :P ' WIR$$O' 1/2" A NGLE S EXI57ING OATEY WMOE 8 615 615 AUU :ST FAN SCHEDULE BACKDRAFT SPEED CONTROLLED BY OR , :'DAMPER CONTROL INTERLOCKED WITH SONES WEIGHT ( Ibs) FIXTURE SCHEDULE CONNE MCA MOP T TO INC ELECTRICAL SWITCH LOCATION PACKAGED UNIT SCHEDULE STARTER FURN, BY DISCONNECT FURN. BY DUCT SMOKE DETECTOR REMARKS NO OC)C)00 COTES '.FOR :EXHAUST . FAN -: S'CFIEDULE . • , • MODIFY . WALL OPENING • TO • •AtCOMMODATE� FAN, -INSTALLATION; . CONNEC TO EXISTING DUCTWORK. ®PROVIDE ' WITI-I 24' HOUR 'PROGRAMMABLE TIMER (LEVE TON '642140. SE EXHAUST FAN MATRIX SHEET M4,0 FOR TIMER SCHEDULE, 'NOTES FOR • PLUMBING • FIXTURE SCHEDULE;. °CONNECT TO EXISTING- PLUMBING .UTILITIES . . • ,NOTES:: PPR ROOFTOP.. PAC1 At ED ., UNIT :SOHE DULEE. . ' , '. PROVIDE . WITH SINGLE _POINT, , ELE I4AL •, ,KIT. 1-IEAT. EXCHANGER 'SHALL E 409-' :. STAINLESS STEEL. • : • 0'' PROVIDE .24V CONTROL W /', .DUQTS1'AT ;' 2 •StAGE GAS . CONTROL;.: AND HIGH . AMBIENT :CUT ® : PROVIDE .W / OSA : FILTER .HOOD : . • ' , • • , :' PROVIDE WITH CURB EXTENSION'' : (MINIMUM .1$'" HIGH), COQROII4ATE •;WITH . C.C. FOR ROOFING CONFIGURATION PRIOR TD ORDERING, UNIT: NO • CDI-1- ,SOS •CEILING DII: PUSS R. SIDEWALL SUPPLY DIFFUSER NOTES F . GRILLES Q:.. REGISTERS. : "DIFFUSERS .....SCHEDULEs: • .' . • . . 1 MODEL N6.•. .'8c ' AIR,.: . PA1I'EIRN . :•SHAfL BE . - SAME .AS CD- I; THRU,.CE74, EXCEPT PROVIDE. • FOR ,: MOUNTING INDICATED. c FURNISH WITH O POSED' .BLADE :DAMP "(OBD). ' r • i DELDEFLECTION 'ERSL-DiI` FUSERS SCHEDULE T TO LNG 1 1/ c # INDICATES AIR PATTERN 1 1/ WHITE ® FRAME 6 INSTALL SHOWERHEAD ©7' -0" APP. PROVIDE NEW SHOWERHEAD ARM AND TUB FILLER PROVIDE WITH INTEGRAL SHOCK ARRESTORS AT SHUTOFF VALVES, CONNECT TO EXISTING WASTE. INSTALL AT HEIGHT RECOMMENDED BY WASHING MACHINE MANUFACTURER. WHITE c WITHOUT MOUNTING HOLES. NOTES FOR ROOFTOP PACKAGED UNIT SCHEDULE 8 1 PROVIDE WITH SINGLE POINT ELECTRICAL CONNECTION KIT, 2 PROVIDE WITH THERMOSTAT, DIGITAL INTERFACE MODULE, WALL SLEEVE, OUTDOOR GRILLES AND SUB BASE KIT, r' r'! = cha ;3 to cenps • �- ... �^� � p7:7. cf F3: Boos :cns vv ;:i rcqu!: 2 a ncvv submittal and may include addUonal plan review faes. Flan review cpproval is subject to errors and omissbet Approval c7 c_7,:`•action documents does not authorize the violation c` cxe;:�cd code or ordinance: Receipt Of apprcvcJ ; ; C::,_y cond :tio is acknow BY Date* -7- 17 0 Pt. Oty of '1'Ukwila BUILDING DIVISION I ?Go'7 (11 D 807 SW Grady Way Suite 210 Renton, WA 98056 425.226.3522 Phone 425.226 "9115 Fax EGIS Housing Unlimited Partnership SHEET: IERts 3/f1 OS co l ast i s- p co) w 00 riz c 7 : 1 ce < a= 0 z " co 0 6 <zz U.I —±— 0 C fraD > 0 CE C6 < < CC ra z16 1 -9 CC F- LU CC 2628 M1.0 ISSUE: CONSTRUCTION DOCUMENTS DATE: 18 MAY 2007 SHEET TITLE: MECHANICAL LEGEND AND SCHEDULES SHEET SIZEL TRIM 0h�1+ *WH ON HORIZONTAL LIME MPASURES 1" IN LENGTH 'RECEIVED JIB 1 9 '. :j PERMIT CENTEI MAINTENANCE & STORAGE 107 211 1 208 ,.. 12 11 MOO C 1 206 0 C8 C9) 207 1 204 .J 205 1ST FLOOR MECHANICAL DEMOLITION PLAN 118" -1' -0" L 1/8" =1'.O _ .. L 203 1 1 202 0 201 1 J C 2ND FLOOR MECHANICAL DEMOLITION PLAN 18) (‘ - r; GENERAL DEMOLITION NOTES • 1. THE EXISTING DOMESTIC WATER SYSTEM IS TO BE KEPT FUNCTIONAL UNTIL THE NEW SYSTEM IS INSTALLED. THE EXISTING SHUTOFF VALVES. TO THE UNITS, IN THE CORRIDORS ARE PRESUMED TO BE UNSERVICEABLE. 2, CORRIDOR PIPING SHOWN IS TO BE REMOVED AT THE COMPLETION OF THE DOMESTIC WATER SYSTEM AND THE NEW HOT WATER HEATING SYSTEM, SIZES SHOWN ON DEMOLITION PLANS ARE APPROXIMATE. 3, AT NO TIME SHOULD THE EXISTING PLUMBING SYSTEM BE CONNECTED TO THE NEW PLUMBING SYSTEM. 4 COORDINATE ALL WORK WITH GC FOR ANY HAZARDOUS MATERIAL ABATEMENT REQUIREMENTS. 5. SEE TYPICAL UNIT MECHANICAL DEMOLITION PLAN THIS SHEET, DEMOLITION NOTES �.. • REMOVE EXHAUST FAN & GRILLE. O REMOVE FAUCET, SUPPLIES & STOPS, O REMOVE SHOWER /TUB MIXING VALVE, SHOWER HEAD & FILLER SPOUT, SHOWER HEAD TO BE RETAINED FOR REINSTALLATION. COORDINATE WITH GC FOR TILE REMOVAL. • REMOVE EXPOSED CLOTHES WASHER SUPPLY PIPING & VALVES. CLOTHES WASHER WASTE STAND PIPE TO BE REMOVED TO BEHIND FINISHED WALL TO ACCOMMODATE FUTURE WORK. • REMOVE CLOTHES DRYER VENT PIPING FROM CLOTHES DRYER. TO EXTERIOR WALL CAP, WALL CAP & SLEEVE TO BE RETAINED, 0 SEE TYPICAL UNIT DEMOLITION PLAN THIS SHEET, O REMOVE DOMESTIC WATER PIPING, INSULATION, HANGERS & APPURTENANCES IN CEILING SPACE. 0 REMOVE DRINKING FOUNTAIN AND APPURTENANCES, CAP WASTE PIPING BELOW SLAB, CAP CW IN WALL SPACE. O REMOVE EXPOSED ACCESSIBLE PLUMBING TO WATER HEATER. WATER HEATER TO REMAIN. 5101 r EX BRED TYPICAL UNIT MECHANICAL DEMOLITION PLAN 1/4"=1 11AY 2 4 Zoo8 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 1 6 2007 . City Of Tukwila B I ' IN : ! IVISION 607 SW Grady Way Suite 210 Renton, WA 98055 425.226.3522 Phone 425.226.9115 Fax STAMP I vxP1R$s m3 l ih in 1 EGIS Housing Unlimited Partnership V ia" 0 IX CCDC) = t E Q Imm W g (IQ 0 P nr ilmm r ISSUE: CONSTRUCTION DOCUMENTS DATE: 18 MAY 2007 SHEET TITLE: 1ST &2ND FLOOR TYPICAL UNIT MECHANICAL DEMOLITION PLANS SHEET : 2628 M2.0 SWAT HORIZONTAL UNE MEADS P 11 LENOTH RECEIVED JUN 19 Zu87 PERMIT CENTEh _ • .N • S 0 - 311 r.310 •I 1 30811 0[ C 0 . 0 307 316 •305 304 10 3RD FLOOR MECHANICAL DEMOLITION PLAN '118" "0" (;) (To ROOF MECHANICAL DEMOLITION PLAN 118" =1 E 1 �J�1lJ •� ;; tiI r_ S IR: HP"' 14 ,15 C8� OR (1 16) • Q) GENERAL DEMOLITION NOTES 1. THE EXISTING DOMESTIC WATER SYSTEM 1S TO BE KEPT FUNCTIONAL UNTIL THE NEW SYSTEM IS INSTALLED. THE EXISTING SHUTOFF VALVES, TO THE UNITS, IN THE CORRIDORS ARE PRESUMED TO BE. UNSERVICEABLE. 2. CORRIDOR PIPING SHOWN IS TO BE REMOVED AT THE COMPLETION OF THE DOMESTIC WATER SYSTEM AND THE NEW HOT WATER HEATING SYSTEM. SIZES SHOWN ON DEMOLITION PLANS ARE APPROXIMATE, 3. AT NO TIME SHOULD THE EXISTING PLUMBING SYSTEM BE CONNECTED TO THE NEW PLUMBING SYSTEM, 4. COORDINATE ALL WORK WITH GC FOR ANY HAZARDOUS MATERIAL ABATEMENT REQUIREMENTS, 5. SEE SHEET M2.0 FOR TYPICAL UNIT MECHANICAL DEMOLITION PLAN. DEMOLITION NOTES SEE TYPICAL UNIT MECHANICAL DEMOLITION PLAN SHEET M2.0. O. RETAIN ALL PLUMBING AND DUCT VENTS ON ROOF, REMOVE TERMINATIONS AS REQUIRED TO FACILITATE THE REMOVAL AND REPLACEMENT OF THE ROOFING. COORDINATE WITH GC FOR EXACT SEQUENCING OF WORK AND FINAL ELEVATIONS OF ROOFING TO PROVIDE ADEQUATE EXTENSIONS TO EXISTING TERMINATIONS. l*V EXPIRED Mid c J REVIEWED FOR CODE COMPLIANCE APPROVED 1 JUL 1 6 2(101 My Of Tukwila Orkfic,M 1 firms O /?7 /CO 1 ISSUE: CONSTRUCTION DOCUMENTS DATE: 18 MAY 2007 SHEET TITLE: 3R0 & ROOF FLOOR DEMO PLANS kitik4 o•r• architec 607 wry Grady Way Suite 210 Renton, WA 98055 425,226.3522 Phone 425,226.9115 Fax 2628 imenommaimismaialmingsvinmin SHEET: M2.1 SHEET SI TRUE. SCALE WHEN HORIZONTAL LINE MEASURES 1* IN LENGTH RECEIVED JUN 1 9 2007 PERMIT CENTER Tr Ia man Mil TENANCE & STORAGE 1 IOC - COM N ' OOM 1 6 • w 1ST FLOOR MECHANICAL PLAN 1/8":11 2ND FLOOR MECHANICAL PLAN 118' =1'ifl" 19) E 11 : I ( 13 13) 014) (15) ( T J ETD ';) CONSTRUCTION NOTES 0 18x18 SD SIDE WALL SUPPLY DIFFUSER, INSTALL FIRE SMOKE DAMPER AT PENETRATION OF CHASE WALL. COORDINATE WITH GC FOR FLUSH INSTALL OF DIFFUSER ON FACE OF WALL. COORDINATE CONNECTION OF DAMPER TO FACP W /FIRE ALARM CONTRACTOR. SEE RPU-1 INSTALLATION DETAIL SHEET M4,0, 0 AREA RESERVED FOR FIRE SPRINKLER HEADER SEE FIRE SPRINKLER DRAWINGS FOR CONTINUATION. c DOMESTIC WATER HEADER. SEE DETAIL ON SHEET M4.0, 0 AREA RESERVED FOR GAS METER. CONTRACTOR TO COORDINATE WITH GAS PURVEYOR FOR METER INSTALLATION. 5 SEE TYPICAL UNIT MECHANICAL PLAN THIS SHEET & TYPICAL UNIT STACK PIPING DETAIL SHEET M4.0. 0 CONNECT NEW DOMESTIC WATER TO EXISTING WATER HEATER: 2 "CW SERVICE, SEE SHEET C1 ,O FOR CONTINUATION OF PIPING, GAS PIPING UP TO RPU-1. SEE NATURAL GAS RISER DETAIL SHEET M4,0. 0 CONNECT TO EXISTING PLUMBING FIXTURE. PROVIDE NEW SUPPLY STOPS AND RISERS. "CW, SUPPLY STOP & RISER TO WATER CLOSET. BEDROOM . � aft 00. KITCHEN MECHANICAL PLAN 114 "671'4" r=1 Er* TYPICAL UNIT MECHANICAL PLAN 114" w 1 -0" LMNd- DINING Sr TYPICAL UNIT MECHANICAL PLAN 114" =1' -0" EF- P -1 EX MAY 2 4 r3 6 ISSUE: CONSTRUCTION DOCUMENTS DATE: 18 MAY 2007 SHEET TITLE: 1ST &2ND FLOOR& TYPICAL UNIT MECHANICAL PLAN 1 607 SW Grady way Suite 210 Renton, WA 98055 425.226,3522 Phone 425.226.9115 Fax SHEET: M3.0 SHEET SIZEIRLIS SCALEYV 1 HORIZONTAL LINE M ASURE31-• INLENGTH ■ 'RECEIVED JUN 19 2007 PERMIT CENTEP 0 (1) 118" n 118" =1 -0" 3RD FLOOR MECHANICAL PLAN ROOF MECHANICAL PLAN a L 303 r 1 301 X 0 16 CONSTRUCTION NOTES 1 18x18SDS 245 CFM SIDE WALL SUPPLY DIFFUSER. INSTALL FIRE SMOKE DAMPER AT PENETRATION OF CHASE WALL. COORDINATE WITH GC FOR FLUSH INSTALL OF DIFFUSER ON FACE OF WALL. COORDINATE CONNECTION OF DAMPER TO FACP W /FIRE ALARM CONTRACTOR. ROOFTOP GAS VENTILATION UNIT (RPU -1). COORDINATE WITH GC ON EXACT LOCATION TO ALLOW DIRECT DROP OF DUCTING INTO NEW CHASE. SEE INSTALLATION DETAIL ON SHEET M4,O. 3 SEE TYPICAL UNIT MECHANICAL PLAN SHEET M3.0 & TYPICAL UNIT STACK PIPING DETAIL SHEET M410, 40 GAS PIPING UP TO RPU -1. SEE NATURAL GAS RISER DETAIL SHEET M4.0. _c; ) 1 EXPO MAY 2 4 Z008 R�V iEWED � COpE OPROVED 620 1347 SW Grady Way Suite 210 Renton, WA 98055 425.225.3522 Phone 425.228.511 5 Fax STAMP DRRES EGIS Housing Unlimited Partnership y V LU co CD a l aul. 0 I. � z a w o � t9 � Z Z E Q w LA ins fmn Tam CC IMINI Uzi ISSUE: CONSTRUCTION DOCUMENTS DATE: 18 MAY 2007 SHEET TITLE: 3RD & ROOF MECHAN ICAL PLAN 2628 SHEET: M3.1 SHEET $IZR TRW $C{118WH N HORIZONTAL LINE MEASURES 1' IN LENCITH RECEIVED JUN 19 2007 PERMIT CENTER GASKET BY EQUIPMENT MANUFACTURER. ACTURER. WOOD NAILING' STRIP 'BY. G.C, COUNTER FLASHING BY MECH, . • CONTRACTOR. • TREATED. BLOCKING CANT &•' MOUNTING FRAME BY MFR. •• . . ROOF MOUNTING • FRAME FURNISHED WITH 'UNIT. GAS • PIPE CONNECTION,. FIELD :VERIFY EQUIPMENT CONNECTION 'LOCATION; EXTEND 'EXISTING AND NEW GAS.. • • ..AS. NECESSARY, • FLEX 'CONNECTION SUPPLY DUCT SIZE AS INDICATED . ON FLOOR PLANS, T PACKAGED .UNIT • INSTALLATION DETAIL .RPU --1 OSA FILTER., H+DOa . . ROOF • 14x4-.SD • • ' • Cm, , . • NOT..' TO . SCALE 14x"1.4 �SD • 2445 CFM , . . 14x 4 (Th . ..OF 2) • • 2ND rLOO 12x12. SD, 185 CFM • • . .• FIRE SMOKE. • DAMPER (TYPICAL • • : • . • • ROOFTOP PACKAGED UNIT INSULATION BY M.C. • ROOFTOP PACKAGED UNIT EXTEND GAS FLUE 24 ", ABOVE UNIT. OUTSIDE AIR HOOD. FINISHED . ROOF .SHOWER HEAD •INSTALL. @ 7'_O» AFF SPOUT (XING ..VALVE NOTES: NATURAL GAS PIPING SIZED PER EQUATION 4-1 OF THE 2003 IFGC. 150' DISTANCE FROM METER TO FURTHEST NATURAL GAS FIXTURE, NATURAL GAS RISER DIAGRAM DIAGRAMMATIC WATER CLOSET LAV SUPPLY STOP & RISER (TYPICAL) NO SCALE 3RD FLOOR UNIT PIPING SAME AS FIRST FLOOR � 2ND FLOOR UNIT PIPING SAME AS FIRST FLOOR CW RISER & UNIT SHUTOFF VALVE IN HOT WATER TANK CAVITY TYPICAL UNIT STACK PIPING DETAIL EXISTING UNDER COUNTER HOT WATER TANK CW MAIN & VALVE IN CORIDOOR KITCHEN SINK (fo — ( FULL SIZE SHOCK ARRESTOR DOMESTIC CW FROM �$ METER SIZE PER PLAN PIPE SLEEVE PER SPECIFICATIONS 2Y "PRESSURE REDUCING VALVE, WILKINS 500 SERIES. SET AT 80 PSI © OUTLET; VERIFY PSI 0 PRV INLET PRIOR TO INSTALLATION. Old I t II x-11 - ..•---- } -.-I% TOTALIZING TYPE WATER METER (PROVIDED BY OWNER) FULL SIZE BY-PASS 2 DOUBLE CHECK VALVE, WILKINS MODEL 950. NOT TO SCALE SUPPORT PIPE (TYPICAL) CW TO BUILDING, SIZE PER PLANS r 1.4•1■111 , 11•61.141144•IMMIIIIMMM.6+ 1 FULL SIZE HEADER DOMESTIC WATER HEADER DETAIL COMPLIAN A.1L 1 6 no City Of �udcwita N' ILO NG fl IO EXPI ED MAY 2 4 2008 EXPANSION TANK (AMTROL ST -80V). STAMP m Y "ay Suite 210 Renton, WA 98055 425.226.3522 Phone 425.226.9115 Fax f tons /17/08 1 EGIS Housing Unlimited Partnership i nms Imam 41 cc cc 7,6 o a . o.oz a�W° Q Ili - ±is z z 0 !was Irmo IX J ISSUE: CONSTRUCTION DOCUMENTS DATE: 18 MAY 2007 SHEET TITLE: MECHAN ICAL DETAILS SHEET: 2628 M4.0 SHEET 812E TRUE SCALE WHEN H O R I Z O N T A L LINE MEASURE 1' IN L ENC TH RECEIVED JUN 1 9 2007 PERMIT CENTER RIVERTON EXHAUST TIME MATRIX . Hours of Bathroom Exhuast Fan Operation Room Number 12am tam 2am -4am 4am -6am Sam -Sam Barn-10am 10am -12pm 12pm - 2pm 2pm -4pm 4pnr8pm 6pm -8pm Spm -10pm 10pm - 12am 104 X X X X 105 X _ X X x 108 C X 107 X 108 y X X r .rirrrr 109 r x . x X x ,... y A x .r � y x 110 111 x X x _ x 201 x X x - K 203 x r. x x x 204 X X X X 205 X IX IX X X X III: 206 . 207 208 210 x X X X 211 x X x . _ X 212 x x x 301 303 X x x x 304 X X X X 305 . . X X X X 306 X X X X _ 307 X X X X 308 309 X x X X 310 x X • X X 311 x, X X X 312 y X . .., x ....._.�....s......� __ __- . ,...wal..........., _� . � .__ ..._ ____ .. . ..._._- .__.... ...e._._ _...* GASKET BY EQUIPMENT MANUFACTURER. ACTURER. WOOD NAILING' STRIP 'BY. G.C, COUNTER FLASHING BY MECH, . • CONTRACTOR. • TREATED. BLOCKING CANT &•' MOUNTING FRAME BY MFR. •• . . ROOF MOUNTING • FRAME FURNISHED WITH 'UNIT. GAS • PIPE CONNECTION,. FIELD :VERIFY EQUIPMENT CONNECTION 'LOCATION; EXTEND 'EXISTING AND NEW GAS.. • • ..AS. NECESSARY, • FLEX 'CONNECTION SUPPLY DUCT SIZE AS INDICATED . ON FLOOR PLANS, T PACKAGED .UNIT • INSTALLATION DETAIL .RPU --1 OSA FILTER., H+DOa . . ROOF • 14x4-.SD • • ' • Cm, , . • NOT..' TO . SCALE 14x"1.4 �SD • 2445 CFM , . . 14x 4 (Th . ..OF 2) • • 2ND rLOO 12x12. SD, 185 CFM • • . .• FIRE SMOKE. • DAMPER (TYPICAL • • : • . • • ROOFTOP PACKAGED UNIT INSULATION BY M.C. • ROOFTOP PACKAGED UNIT EXTEND GAS FLUE 24 ", ABOVE UNIT. OUTSIDE AIR HOOD. FINISHED . ROOF .SHOWER HEAD •INSTALL. @ 7'_O» AFF SPOUT (XING ..VALVE NOTES: NATURAL GAS PIPING SIZED PER EQUATION 4-1 OF THE 2003 IFGC. 150' DISTANCE FROM METER TO FURTHEST NATURAL GAS FIXTURE, NATURAL GAS RISER DIAGRAM DIAGRAMMATIC WATER CLOSET LAV SUPPLY STOP & RISER (TYPICAL) NO SCALE 3RD FLOOR UNIT PIPING SAME AS FIRST FLOOR � 2ND FLOOR UNIT PIPING SAME AS FIRST FLOOR CW RISER & UNIT SHUTOFF VALVE IN HOT WATER TANK CAVITY TYPICAL UNIT STACK PIPING DETAIL EXISTING UNDER COUNTER HOT WATER TANK CW MAIN & VALVE IN CORIDOOR KITCHEN SINK (fo — ( FULL SIZE SHOCK ARRESTOR DOMESTIC CW FROM �$ METER SIZE PER PLAN PIPE SLEEVE PER SPECIFICATIONS 2Y "PRESSURE REDUCING VALVE, WILKINS 500 SERIES. SET AT 80 PSI © OUTLET; VERIFY PSI 0 PRV INLET PRIOR TO INSTALLATION. Old I t II x-11 - ..•---- } -.-I% TOTALIZING TYPE WATER METER (PROVIDED BY OWNER) FULL SIZE BY-PASS 2 DOUBLE CHECK VALVE, WILKINS MODEL 950. NOT TO SCALE SUPPORT PIPE (TYPICAL) CW TO BUILDING, SIZE PER PLANS r 1.4•1■111 , 11•61.141144•IMMIIIIMMM.6+ 1 FULL SIZE HEADER DOMESTIC WATER HEADER DETAIL COMPLIAN A.1L 1 6 no City Of �udcwita N' ILO NG fl IO EXPI ED MAY 2 4 2008 EXPANSION TANK (AMTROL ST -80V). STAMP m Y "ay Suite 210 Renton, WA 98055 425.226.3522 Phone 425.226.9115 Fax f tons /17/08 1 EGIS Housing Unlimited Partnership i nms Imam 41 cc cc 7,6 o a . o.oz a�W° Q Ili - ±is z z 0 !was Irmo IX J ISSUE: CONSTRUCTION DOCUMENTS DATE: 18 MAY 2007 SHEET TITLE: MECHAN ICAL DETAILS SHEET: 2628 M4.0 SHEET 812E TRUE SCALE WHEN H O R I Z O N T A L LINE MEASURE 1' IN L ENC TH RECEIVED JUN 1 9 2007 PERMIT CENTER A B 4" FIRE HYDRANT (EXISTING) SITE SYMBOLS - I gi I I f=i 11 =LI 1'-I =I I E1 I E I E= l= T -1►1= _11 HImo_- 111 -11 I-L--L -11=111 I- 11=111=111=111=1 - I11w111- 111 - 1I II= 'Ell - 1:7111E - 11E1 'IE11I „11E11 4” FROM SUPPLy ii ., JL�1 ={ I k 1.1.1 =1I =111 = 111 1 111 =I 1 E1 E Ill - 11111 E 11E111E11E1 1 =I f 1 =11 —I 11i =1 I iii L —I1 =I ;III U -HOOK SUPER SCREW CITY CONNECTION (BY OTHERS) SITE PLAN SCALE: 1 " = 30' -0" SCALE: 1/2" =1-0" HANGER LEGEND L M L ASS DI RIVERTON TERRACE BUILDING "H" SE)i CE m FSW START POINT WITH Pi : REDFF1 r \ PIPING BY FSW -- -� — -- - EXISTING PIPING PIPING BY OTHERS FIRE DEPARTMENT CONNECTION POST INDICATOR VALVE L -ROD WASHER PLATE I I , I ii M AINTAIN 2" ANNULAR CLEARANCE AROUND ALL CONCRETE PENETRATIONS SYM R� I I C.. }T.. 1 1 4 x 4" STORTZ FDC `' 41 i ( 1R8 1 - EXISTING FIRE HYDRANT z GATE VALVE IN ROADWAY BOX - NEW FIRE HYDRANT C 1L STREET CENTER LINE R PROPERTY LINE 5 -9 FITTER 1 LISTER NOTES : TYPE 4" P.I.V. 'NI TAMPER (BY OTHERS) RISER ELEVATION TMRVST BUT CHIT; PER t ^F+. +v VIMr,R;15TRK T'n r 5 M D t411 S 4 1. DISCHARGE MAIN DRAIN TO A SAFE LOCATION OUTSIDE. 2, MAINTAIN A 2" ANNULAR SPACE AROUND ALL PIPES PASSING THROUGH CONCRETE. Y uDGR&utsb WORK ANb (A) 0 evi4 IIJS U TY R.D. W. g tars seeti-go Maw n k)DQ4LS p MFG MODEL ORIFICE 5 , V k q cQ N THREAD FLOW TEST INFORMATION FLOW TEST INFORMATION GIVEN BY BCE ENGINEERING FLOW TEST LOCATION: WATER METER ACROSS S. 144th ST. FROM 4021 FLOW TEST DATE: 1/19/2007 STATIC PRESSURE 80 PSI RESIDUAL PRESSURE 52 PSI FLOWING: 2990.1 G.P.M. A ' 4 4 , oQ p C CONCRETE INSERT N D TOP BEAM CLAMP P POWDER DRIVEN STUD E R WEDGE ANCHOR F HDI - P T TRAPEZE G CEILING FLANGE U H SIDE BEAM BRACKET W J SIDEWINDER x K SHORT CLIP Y TOTAL TOT SPRINKLER HEADS TEMP FINISH RO Item Number 3 4 5 6 7 S Quantity 1 1 1 1 1 12 head Size Description 4" Wilkins Zurn 350ADA BGVIC GxG Backflow Preventer WI Tamper Switch 4" Victaulic Mod. 717 Check Valve GxG 1W Victaulic 728 Fireiock Bail Valve w/ Tamper Switch TxT 1 ,6 Pressure Gauge 1 Potter VSR -SF Water Flow Indicator 1" AGF 1000 Test and Drain 10" Electric Alarm Bell — Spare Head Cabinet containing a Stock of the Following Spare Sprinklers and Wrenches Quantity 2 6 2 E TO LAUNDRY M FLOOR DRAIN 1 RISER MATERIAL LIST SPARE SPRINKLERS AND WRENCHES Description Pendent, Viking, VK404. BRASS/WHT 1/2" x 5.6K 155", QR, Concealed Upright, Viking VK 300, 1/2" x 5 6K 155', W, Brass Sidewall, Viking VK 450, WHT/ WHT 1/2" x 4.1K, 155', QR, Recessed Pendent, Viking VK 425, BRASS! WHT 1/2" x 4.2K, 155', QR, Concealed Sidewall, Viking VK 305, CHROME/ CHROME 1/2" x 5 6K, 155', QR, Recessed Viking Wrench , Part No. 10896WIB Viking Wrench, Part No. 10366W/B Viking Wrench. Part No, 07398W Manufacturer Wilkins/ Zurn Victaulic Victaulic Kennedy Potter Electric AGF Potter Electric Manufacturer Viking Viking Viking Viking Viking Viking Viking Viking CANOPY QTY A A n .')l••- 1.1.7 -, MK A A (3 DATE AUTHORITY BY APPROVALS REQUIRED: OWNER / ARCHITECT DISTRIBUTION: city ut I uhwlla REVISIONS DESCRIPTION OWNER / ARCHITECT FIRE SYSTEMS WI°:SI 3 2 (FACING NORTH) UNDERGROUND NOTES: 1) ALL UNDERGROUND TO BE BY OTHERS. CONTRACTOR TO BE STATE LICENSED AND CERTIFIED TO INSTALL UNDERGROUND PIPING PER WAC 212 -80. 2) PIPE TYPE AND CLASS TO MEET LOCAL JURISDICTION APPROVAL. 3) ALL UNDERGROUND PIPING SHALL HAVE 3 FEET MINIMUM BURY (TO TOP OF PIPE). 4) ALL UNDERGROUND PIPING SHALL BE UL LISTED AND /OR FM APPROVED FOR FIRE PROTECTION. ALL PIPING WITHIN 5' -0" OF BLDG TO BE MIN CLASS 52 DUCTILE IRON. 5) ALL UNDERGROUND PIPING SHALL BE RESTRAINED IN ACCORDANCE WITH THE SPECIFICATIONS AND NFPA 24 (LATEST EDITION). 6) ALL UNDERGROUND PIPING SHALL BE HYDROSTATICALLY TESTED AT NOT LESS THAN 200 PSI OR 50 PSI ABOVE STATIC PRESSURE IN EXCESS OF 150 PSI FOR TWO HOURS IN ACCORDANCE WITH NFPA 24 (LATEST EDITION). 7) ALL UNDERGROUND PIPING SHALL BE FLUSHED IN ACCORDANCE WITH NFPA 24 (LATEST EDITION). FLOW THE REQUIRED RATE UNTIL WATER IS CLEAR AS INDICATED BY NO COLLECTION OF FOREIGN MATERIAL IN BURLAP BAGS AT OUTLETS. 4" - 490 GPM 6" - 880 GPM 8" - 1,560 GPM 8) ALL UNDERGROUND PIPING SHALL BE STERILIZED PER LOCAL JURISDICTION REQUIREMENTS. 10" - 2,400 GPM 12" - 3,520 GPM GENERAL NOTES 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UNDERWRITERS APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISER & DIMENSIONS SHOWN THUSLY (1' -6 ") WHICH ARE END TO END. 3.EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA #13. 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13. 5.PIPING SHALL BE IN ACCORDANCE WITH NFPA #13. 6. JOINING OF PIPE AND FITTINGS. THREADED AND WELDED SHALL BE IN ACCORDANCE WITH NFPA #13. 7. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY WET PIPE SPRINKLER SYSTEM. 8. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKI FR PIPING IS THE RESPONS113I1 I I Y C]I 11 It OWNI 11 oft I IIS S I I' UC I UHAL ItLPIlESEN IA I IVE. ROOF LEVEL BUILDING CROSS SECTION SCALE: N.T.S. MAINTAIN 2- ANNULAR CLEARANCE AROUND ALL PIPE PASSING THROUGH CONCRETE 3-6 RISER AREA FLOORPLAN SCALE: 1 /2" =1' -0" DESIGN CRITERIA AND NOTES 1. ALL MAIN AND GRIDDED BRANCHLINE PIPING TO BE SCHEDULE 10 JOINED WI GROOVED COUPLINGS AND FITTINGS(UNO). 2. ALL TREE BRANCHLINE PIPING TO BE SCHEDULE 40 JOINED W/ CAST IRON THREADED FITTINGS. 3. ALL DRY MAIN PIPING TO BE SLOPED AT 1/4" PER 10' -0" AND ALL DRY LINE PIPING TO BE SLOPED AT 1/2" PER 10' -0 ". 4. ALL GROOVED COUPLINGS TO BE RIGID ram"), UNLESS SHOWN AS: (" : : _ ") DENOTING A FLEXIBLE COUPLING. 1 i w BUILDING PERMIT # EXPI MAY 2 4 2N8 CONTRACT WITH: W.G. Clark Construction 401 Aurora Ave. N Seattle WA 98109 f'rojoc:I Willow)! Ft Ic F ()IOlt;()l1 I'II(rli(y :'l )1) OJ +I tl;' +I'I I J(1) SCOPE OF FIRE SYSTEMS WEST SYSTEM IN AN EXISTIN FSW WILL START WOR CLARIFIC - ALL AREAS OF WET P MINIMUM 40 ° F TO PREY EXCLUSIO - PAINTING OR LABELIN - CENTRAL STATION M DESIGN C PER NFPA 13(2007) AN — RESIDENTIAL UNITS RESIDENTIAL HAZAR DESIGN DENSITY : PE -CORRIDORS LIGHT HAZARD DESIGN DENSITY : 0 -1 - LOBBIES/ COMMUNITY LIGHT HAZARD DESIGN DENSITY : 0.1 RECEIVED MAY 1 T 2007 TUKWILA PUBLIC WORKS D 11401--oGi Ft,O7•l7 CONTRACT NAME: Riverton Terrace 14410 41st Avenue South Tukwila WA 98168 FSW) WILL PROVIDE AN AUTOMATIC WET PIPE FIRE PROTECTION SPRINKLER G MULTIFAMILY RESIDENCE. K AT A FLANGE CONNECTION 6" INSIDE THE BUILDING (PROVIDED BY OTHERS) IPE INCLUDING ALL VALVES AND RISERS MUST BE MAINTAINED BY OTHERS AT A ENT FREEZING. NS G OF PIPE AND /OR EQUIPMENT - ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES ONITORING EQUIPMENT, WIRING AND SERVICES RITERIA D CITY OF TUKWILA R HEAD LISTING FOR 4 MOST DEMANDING O GPM / 5 HEADS 0 GPM / LARGE ROOM -- STORAGE/ MECHANICAL ROOMS ORDINARY HAZARD GROUP 2 DESIGN DENSITY : 0.20 GPM / LARGE ROOM REFER- 73 Pto 07- Fog- 4" lz• ii\AsTALLPtTio „s ilent, Inc, �qo o Itl■ • ca WORK TIONS ROOMS/ PUBLIC RESTROOMS VICINITY MAP SCALE: N. T. S. SITE PLAN AND DETAILS Fire Systems West 219 Frontage Road North, Suite B Pacific, WA. 98047 (253) 833 -1248 Fax: (253) 735 -0113 (a (; I AI l I IY I II 611( 1111 1_4 I Il�fv�fl 1 11111 11 WA CLH FIRESWI 14 0B1 (a c INr11AI I Irr )/1I I Il )I1 I'111M111 I( III II I I u uil r i ill no I III i1 3rd f 16" UL. 4 Eft? o UNIT r UNIT CORRIDOR WALL�2n -**2 x 4 STU 2 GATT IN �_i 9,6 -4 UNIT • CORRIDOR UNIT UNIT • • CORRIDOR .. !'• 1 6? . • O.C. ;• CEILING 1 m 2x GAB. T ©16" O.C. 3W x STUD 2 x 5f8 G.W. 2" BATT IRSUL. A B 4" FIRE HYDRANT (EXISTING) SITE SYMBOLS - I gi I I f=i 11 =LI 1'-I =I I E1 I E I E= l= T -1►1= _11 HImo_- 111 -11 I-L--L -11=111 I- 11=111=111=111=1 - I11w111- 111 - 1I II= 'Ell - 1:7111E - 11E1 'IE11I „11E11 4” FROM SUPPLy ii ., JL�1 ={ I k 1.1.1 =1I =111 = 111 1 111 =I 1 E1 E Ill - 11111 E 11E111E11E1 1 =I f 1 =11 —I 11i =1 I iii L —I1 =I ;III U -HOOK SUPER SCREW CITY CONNECTION (BY OTHERS) SITE PLAN SCALE: 1 " = 30' -0" SCALE: 1/2" =1-0" HANGER LEGEND L M L ASS DI RIVERTON TERRACE BUILDING "H" SE)i CE m FSW START POINT WITH Pi : REDFF1 r \ PIPING BY FSW -- -� — -- - EXISTING PIPING PIPING BY OTHERS FIRE DEPARTMENT CONNECTION POST INDICATOR VALVE L -ROD WASHER PLATE I I , I ii M AINTAIN 2" ANNULAR CLEARANCE AROUND ALL CONCRETE PENETRATIONS SYM R� I I C.. }T.. 1 1 4 x 4" STORTZ FDC `' 41 i ( 1R8 1 - EXISTING FIRE HYDRANT z GATE VALVE IN ROADWAY BOX - NEW FIRE HYDRANT C 1L STREET CENTER LINE R PROPERTY LINE 5 -9 FITTER 1 LISTER NOTES : TYPE 4" P.I.V. 'NI TAMPER (BY OTHERS) RISER ELEVATION TMRVST BUT CHIT; PER t ^F+. +v VIMr,R;15TRK T'n r 5 M D t411 S 4 1. DISCHARGE MAIN DRAIN TO A SAFE LOCATION OUTSIDE. 2, MAINTAIN A 2" ANNULAR SPACE AROUND ALL PIPES PASSING THROUGH CONCRETE. Y uDGR&utsb WORK ANb (A) 0 evi4 IIJS U TY R.D. W. g tars seeti-go Maw n k)DQ4LS p MFG MODEL ORIFICE 5 , V k q cQ N THREAD FLOW TEST INFORMATION FLOW TEST INFORMATION GIVEN BY BCE ENGINEERING FLOW TEST LOCATION: WATER METER ACROSS S. 144th ST. FROM 4021 FLOW TEST DATE: 1/19/2007 STATIC PRESSURE 80 PSI RESIDUAL PRESSURE 52 PSI FLOWING: 2990.1 G.P.M. A ' 4 4 , oQ p C CONCRETE INSERT N D TOP BEAM CLAMP P POWDER DRIVEN STUD E R WEDGE ANCHOR F HDI - P T TRAPEZE G CEILING FLANGE U H SIDE BEAM BRACKET W J SIDEWINDER x K SHORT CLIP Y TOTAL TOT SPRINKLER HEADS TEMP FINISH RO Item Number 3 4 5 6 7 S Quantity 1 1 1 1 1 12 head Size Description 4" Wilkins Zurn 350ADA BGVIC GxG Backflow Preventer WI Tamper Switch 4" Victaulic Mod. 717 Check Valve GxG 1W Victaulic 728 Fireiock Bail Valve w/ Tamper Switch TxT 1 ,6 Pressure Gauge 1 Potter VSR -SF Water Flow Indicator 1" AGF 1000 Test and Drain 10" Electric Alarm Bell — Spare Head Cabinet containing a Stock of the Following Spare Sprinklers and Wrenches Quantity 2 6 2 E TO LAUNDRY M FLOOR DRAIN 1 RISER MATERIAL LIST SPARE SPRINKLERS AND WRENCHES Description Pendent, Viking, VK404. BRASS/WHT 1/2" x 5.6K 155", QR, Concealed Upright, Viking VK 300, 1/2" x 5 6K 155', W, Brass Sidewall, Viking VK 450, WHT/ WHT 1/2" x 4.1K, 155', QR, Recessed Pendent, Viking VK 425, BRASS! WHT 1/2" x 4.2K, 155', QR, Concealed Sidewall, Viking VK 305, CHROME/ CHROME 1/2" x 5 6K, 155', QR, Recessed Viking Wrench , Part No. 10896WIB Viking Wrench, Part No. 10366W/B Viking Wrench. Part No, 07398W Manufacturer Wilkins/ Zurn Victaulic Victaulic Kennedy Potter Electric AGF Potter Electric Manufacturer Viking Viking Viking Viking Viking Viking Viking Viking CANOPY QTY A A n .')l••- 1.1.7 -, MK A A (3 DATE AUTHORITY BY APPROVALS REQUIRED: OWNER / ARCHITECT DISTRIBUTION: city ut I uhwlla REVISIONS DESCRIPTION OWNER / ARCHITECT FIRE SYSTEMS WI°:SI 3 2 (FACING NORTH) UNDERGROUND NOTES: 1) ALL UNDERGROUND TO BE BY OTHERS. CONTRACTOR TO BE STATE LICENSED AND CERTIFIED TO INSTALL UNDERGROUND PIPING PER WAC 212 -80. 2) PIPE TYPE AND CLASS TO MEET LOCAL JURISDICTION APPROVAL. 3) ALL UNDERGROUND PIPING SHALL HAVE 3 FEET MINIMUM BURY (TO TOP OF PIPE). 4) ALL UNDERGROUND PIPING SHALL BE UL LISTED AND /OR FM APPROVED FOR FIRE PROTECTION. ALL PIPING WITHIN 5' -0" OF BLDG TO BE MIN CLASS 52 DUCTILE IRON. 5) ALL UNDERGROUND PIPING SHALL BE RESTRAINED IN ACCORDANCE WITH THE SPECIFICATIONS AND NFPA 24 (LATEST EDITION). 6) ALL UNDERGROUND PIPING SHALL BE HYDROSTATICALLY TESTED AT NOT LESS THAN 200 PSI OR 50 PSI ABOVE STATIC PRESSURE IN EXCESS OF 150 PSI FOR TWO HOURS IN ACCORDANCE WITH NFPA 24 (LATEST EDITION). 7) ALL UNDERGROUND PIPING SHALL BE FLUSHED IN ACCORDANCE WITH NFPA 24 (LATEST EDITION). FLOW THE REQUIRED RATE UNTIL WATER IS CLEAR AS INDICATED BY NO COLLECTION OF FOREIGN MATERIAL IN BURLAP BAGS AT OUTLETS. 4" - 490 GPM 6" - 880 GPM 8" - 1,560 GPM 8) ALL UNDERGROUND PIPING SHALL BE STERILIZED PER LOCAL JURISDICTION REQUIREMENTS. 10" - 2,400 GPM 12" - 3,520 GPM GENERAL NOTES 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UNDERWRITERS APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISER & DIMENSIONS SHOWN THUSLY (1' -6 ") WHICH ARE END TO END. 3.EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA #13. 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13. 5.PIPING SHALL BE IN ACCORDANCE WITH NFPA #13. 6. JOINING OF PIPE AND FITTINGS. THREADED AND WELDED SHALL BE IN ACCORDANCE WITH NFPA #13. 7. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY WET PIPE SPRINKLER SYSTEM. 8. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKI FR PIPING IS THE RESPONS113I1 I I Y C]I 11 It OWNI 11 oft I IIS S I I' UC I UHAL ItLPIlESEN IA I IVE. ROOF LEVEL BUILDING CROSS SECTION SCALE: N.T.S. MAINTAIN 2- ANNULAR CLEARANCE AROUND ALL PIPE PASSING THROUGH CONCRETE 3-6 RISER AREA FLOORPLAN SCALE: 1 /2" =1' -0" DESIGN CRITERIA AND NOTES 1. ALL MAIN AND GRIDDED BRANCHLINE PIPING TO BE SCHEDULE 10 JOINED WI GROOVED COUPLINGS AND FITTINGS(UNO). 2. ALL TREE BRANCHLINE PIPING TO BE SCHEDULE 40 JOINED W/ CAST IRON THREADED FITTINGS. 3. ALL DRY MAIN PIPING TO BE SLOPED AT 1/4" PER 10' -0" AND ALL DRY LINE PIPING TO BE SLOPED AT 1/2" PER 10' -0 ". 4. ALL GROOVED COUPLINGS TO BE RIGID ram"), UNLESS SHOWN AS: (" : : _ ") DENOTING A FLEXIBLE COUPLING. 1 i w BUILDING PERMIT # EXPI MAY 2 4 2N8 CONTRACT WITH: W.G. Clark Construction 401 Aurora Ave. N Seattle WA 98109 f'rojoc:I Willow)! Ft Ic F ()IOlt;()l1 I'II(rli(y :'l )1) OJ +I tl;' +I'I I J(1) SCOPE OF FIRE SYSTEMS WEST SYSTEM IN AN EXISTIN FSW WILL START WOR CLARIFIC - ALL AREAS OF WET P MINIMUM 40 ° F TO PREY EXCLUSIO - PAINTING OR LABELIN - CENTRAL STATION M DESIGN C PER NFPA 13(2007) AN — RESIDENTIAL UNITS RESIDENTIAL HAZAR DESIGN DENSITY : PE -CORRIDORS LIGHT HAZARD DESIGN DENSITY : 0 -1 - LOBBIES/ COMMUNITY LIGHT HAZARD DESIGN DENSITY : 0.1 RECEIVED MAY 1 T 2007 TUKWILA PUBLIC WORKS D 11401--oGi Ft,O7•l7 CONTRACT NAME: Riverton Terrace 14410 41st Avenue South Tukwila WA 98168 FSW) WILL PROVIDE AN AUTOMATIC WET PIPE FIRE PROTECTION SPRINKLER G MULTIFAMILY RESIDENCE. K AT A FLANGE CONNECTION 6" INSIDE THE BUILDING (PROVIDED BY OTHERS) IPE INCLUDING ALL VALVES AND RISERS MUST BE MAINTAINED BY OTHERS AT A ENT FREEZING. NS G OF PIPE AND /OR EQUIPMENT - ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES ONITORING EQUIPMENT, WIRING AND SERVICES RITERIA D CITY OF TUKWILA R HEAD LISTING FOR 4 MOST DEMANDING O GPM / 5 HEADS 0 GPM / LARGE ROOM -- STORAGE/ MECHANICAL ROOMS ORDINARY HAZARD GROUP 2 DESIGN DENSITY : 0.20 GPM / LARGE ROOM REFER- 73 Pto 07- Fog- 4" lz• ii\AsTALLPtTio „s ilent, Inc, �qo o Itl■ • ca WORK TIONS ROOMS/ PUBLIC RESTROOMS VICINITY MAP SCALE: N. T. S. SITE PLAN AND DETAILS Fire Systems West 219 Frontage Road North, Suite B Pacific, WA. 98047 (253) 833 -1248 Fax: (253) 735 -0113 (a (; I AI l I IY I II 611( 1111 1_4 I Il�fv�fl 1 11111 11 WA CLH FIRESWI 14 0B1 (a c INr11AI I Irr )/1I I Il )I1 I'111M111 I( III II I I u uil r i ill no I III i1