Permit PG07-185 - BOEING #9-120
BOEING #9 -120 9725 E MARGINAL WY S PG07.185 Parcel No.: 0003400018 Address: 9725 EAST MARGINAL WY S TUKW Suite No: Tenant: Name: Address: BOEING #9 -120 8725 EAST MARGINAL WY S , TUKWILA WA Owner: Name: BOEING COMPANY THE Address: 100 N RIVERSIDE WC 5003 -4027 , CHICAGO IL Contact Person: Name: DANI MEYERS Address: 1221 2 AV N , KENT WA Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AV N , KENT, WA Contractor License No: HERMACLOO5BJ DESCRIPTION OF WORK: PROVIDE AND INSTALL (5) WATER CLOSETS, (4) LAVS, (1) URINAL, (1) KITCHEN SINK, (1) JANITORS CLOSET, (2) FLOOR DRAINS, (1) BACKFLOW DEVICE, AND (1) DRINKING FOUNTAIN. Value of Plumbing /Gas Piping: Fees Collected: $8,500.00 $247.50 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet doc: UPC -10/06 Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us FIXTURE TYPE AND OUANTITY * *continued on next page ** PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 575 -9700 Phone: 206 - 575 -9700 Expiration Date: 08/25/2008 Uniform Plumbing Code Edition: International Fuel Gas Code Edition: PG07 -185 07/12/2007 01/08/2008 2006 2006 Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 0 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 1 grease interceptors 0 0 Repair or alteration of water piping and/or water 2 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 4 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 0 Gas Piping 0 Gas piping outlets (0 -5) 0 5 Gas piping outlets (6 +) 0 PG07 -185 Printed: 07 -12 -2007 Signature: Permit Center Authorized Signature: City ot°Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PGO7 -185 Issue Date: 07/12/2007 Permit Expires On: 01/08/2008 Date: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit. -- 412(o7 Print Name: Dar L This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC-10 /06 PG07 -185 Printed: 07 -12 -2007 Parcel No.: 0003400018 Address: Suite No: Tenant: doc: Cond -10/06 err' City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 9725 EAST MARGINAL WY S TUKW BOEING #9 -120 1: ** *PLUMBING AND GAS PIPING * ** PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: PG07 -185 ISSUED 07/05/2007 07/12/2007 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. PG07 -185 Printed: 07 -12 -2007 Signature: PYFRO • Print Name: i r tf City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. doc: Cond -10/06 PG07 -185 Date: /' i ordinances governing or local laws regulating Printed: 07 -12 -2007 Site Address: Tenant Name: Property Owners Name: PSPi Mailing Address: Company Name: Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** /2 rir GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Contact Person: P'0� arm- 'fk._. v E -Mail Address: Company Name: �^ ,q ,�.�j Mailing Address: 1 (-Col 5T f ) ► Contact Person: A l h ` - 0 !V �... ' ) Cie. Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) t King Co Assessor's Tax Suite Number: New Tenant: City CONTACT PERSON — who do we contact when your permit is ready to be issued Name: yin i I O /C. Day Telephone: ada Mailin s: I &3t Re_ fl • Il_tJ L Mailing City l State Zip �^�/+� E -Mail Address: i I 1 C ���� .f U lV . � f p 1,� i• Cumber: Company Name: �� � �. rr�� Mailing Address: oc5 1 \..Aa AVe--. 1 1 • U rte_ 00 /1 � \ City �-y State Zip Contact Person: (3i ( M ` Day Telephone: 2 _ 12(p • y �,�� Fax Number: 20 ( D. . ' 1/ E-Mail Address: 328- Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record City �- {� Day Telephone: 23 ( . g' 5 1 R Fax Number: ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record °c r..) City State Day Telephone: 70(0 . O (O� 1 Zap 7 E -Mail Address: W Fax Number: Floor: ❑ Yes 113?1No State Zip State Zip Z i Cczq - 27-.J Q:1Applications\Fonns- Applications On Line 3 -2006 - Permit Applicationdoc Revised 9 -2006 Page 1 of 6 bh Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) 1 Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste 1 _ (` �7T P 1 Clothes washer, domestic Floor drain 'L Sinks `i-- Dental unit, cuspidor Shower, single head trap Urinals 1 Dishwasher, domestic, with independent drain Lavatory c, _ Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPING" PERMIT INFORMATION - 206 -431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION n Qx 122 Znd fsv2 Cl Company Name: Mailing Address: Contact Person: ' 9 - :t r i fne, eXS E -Mail Address: a LV • .6. it If 1 tai _r Contractor Registration Number: C o City / L • State Zi Day Telephone: 2 (, • S 15 ' ��� Number: 20( D • F7 5 ° r7 t) Expiration Date: c 26 Valuation of Plumbing work (contractor's bid price): $ S6, CO Valuation of Gas Piping work (contractor's bid price): $ n /Gk.- Scope of Work (please provide detailed information): Pr 1l I.Sl , '- C -V356S I Y1V na. t c F t• • • * b OA iiiirsmarmilmtwaronwari A Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q:\Applications\Fonns- Applications On Line 3.2006 - Permit Applicatiordoc Revised: 9 -2006 bh Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Signature: Print Name: Mailing Address: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING ER OR AUT IZED A Date Application Accepted: cD-ro -Fx )rbu<_ Q:1Applications\Forms- Applications On Line3-2006 - Permit Applicationdoc Revised: 9 -2006 bh Date Application Expires: Day Telephone: 1 221 Z r ck P n_ \CQ 4, - L./0a )city olloSl17) Date: —7/5/ o / 20(n. 575 .97CO State Zip Staff Initials: Page 6 of 6 Receipt No.: R07 -01295 Initials: JEM User ID: 1165 Payee: HERMANSON CO. LLP ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES PLUMBING - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us RECEIPT Parcel No.: 0003400018 Permit Number: PG07 -185 Address: 9725 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 07/05/2007 Applicant: BOEING #9 -120 Issue Date: TRANSACTION LIST: Type Method Description Amount Payment Check 1718 247.50 Account Code Current Pmts 000/345.830 49.50 000/322.100 198.00 Total: $247.50 Payment Amount: $247.50 Payment Date: 07/05/2007 10:12 AM Balance: $0.00 0020 07/05 9716 TOTAL 247.50 doc: Receiot -06 Printed: 07 -05 -2007 Project: , ,-...-- /Z 0 Type of Inspectiop: • , \(_- Address: 9705 - 7457 12 W' / 2 ‘0"/V/ 1 ( Date Called: Special Instructions: Date / Wanted4 P.m. Requester: Phone No: - /3/ 2 INSPECTION RECORD Retain a copy with permit P‘e 7 /95 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 CO ENTS: nspec ./ 'Date: — / 8.00 REINSPECTION FEE REQU D. Prior to inspection. fee must be 77. aid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. ID ceipt No.: 'Date: Approved per applicable codes. Corrections required prior to approval. Project: B0 61►.16 G f26 Type of Inspection: TZ n -►N A dress: S E A 5 w M ►v t 1,-,i4 1 Date Called: VOL4 C., Special Instru Date Wanted: 10)IS-M-7 a. . dr. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF 'FUKWILA BUILDING DIVISION F- 6300 Southcenter Blvd., #1 00, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. COMMENTS: p h -<( -1W Inspector: 0 REINSPECTION FE ' EQUIRED. P or to inspection, fee must be d at 6300 Southcenter Bl Suite 100. Call the schedule reinspection. pt No.: Date: 'Date: Corrections required prior to approval. g ACTIVITY NUMBER: PG07 -185 DATE: 07 -05 -07 PROJECT NAME: BOEING #9 -120 SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # After Permit Issued Response to Correction Letter # Revision # DEPARTMENTS: 01' Buil • I DtPs ion Public Works �✓ PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Documents/routing slip.doc 2 -28-02 Incomplete ❑ TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DATE: Planning Division Permit Coordinator DUE DATE: 07-10-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DUE DATE: 08-07-07 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License HERMACL005BJ Licensee Name HERMANSON COMPANY LLP Licensee Type CONSTRUCTION CONTRACTOR UBI 602004844 Ind. Ins. Account Id PARTNER/MEMBER Business Type LIMITED LIABILITY COMPANY Address 1 1221 2ND AVE N Address 2 City KENT County KING State WA Zip 980322945 Phone 2065759700 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/11/2000 Expiration Date 8/25/2008 Suspend Date Separation Date Parent Company Previous License HERMAC•217NT Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HERMANSON, RICHARD L PARTNER/MEMBER 01/01/1980 Bond Amount ALMON, KEVIN PARTNER/MEMBER 01/01/1980 MACDONALD, JAMES PARTNER/MEMBER 01/01/1980 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= HERMACL005BJ 07/12/2007 SYM ORIG vICI \I I MAP 99 bn n 14-01 7 -127 KING COUNTY AIRPORT OFFICE CENTER (FM) 99 FROM SEATTLE— TACOMA AIRPORT FROM DOWNTOWN SEATTLE FAST MARGINAL WAY CORPORATE PARK BOEING DEVELOP 599 TUKWILA 900 Exn' 157 MENTAL CENTER FROM KENT & AUBURN EMT 157 NO SCALE 900 BO AREA VIAP BUILDING ADDRESS: 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 9 -120 BUILDING LOCATION NO SCALE \G WORKP AC S-HVC-S B� D \v 9 "20 u# 16054201/02 BOEI\C DEVELOPVE \TAL CE\TER 9725 EAST VARCI\AL WAY SOUTH TU<WILA, WASHI\CTO\ X8108 FCS SPL LABS GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH WORK WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1_ VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO ROCK MOUG, 253-773-8400, AT BUILDING 9 -51.2 AFTER COMPLETION OF WORK OF THIS CONTRACT. PROJECT CHECKLIST • CHECK BOX ® THESE DRAWINGS CONFORM TO THE I.B.C., I.F.C., I.M.C., U.P.C., N.E.C. AND THE WAC 51 -20 AS ADOPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CITY OF TUKWILA, WASHINGTON ZONING. ❑ ROOMS LABELED PER. OCCUPANCY PER I.B.C. TABLE 1004.1.2. ® BUILDING FLOOR NUMBER ON • PRINT FOR AREA OF CONSTRUCTION. ® NUMBER OF PRINTS REQUIRED FOR . PERMIT PACKAGE: ❑ 1. TENANT IMPROVEMENT (STRUCTURAL): ❑ 5 SETS OF ARCHITECTURAL DRAWINGS ❑ 5 SETS OF STRUCTURAL DRAWINGS 0 5 SETS OF STANDARD DETAILS O 5 SETS OF ENGINEERING CALCULATIONS ❑ 5 SETS OF ENERGY CALCULATIONS O 5 SETS OF CONSTRUCTION SPECIFICATIONS ® 2. TENANT IMPROVEMENT (NON— STRUCTURAL): O 4 SETS OF ARCHITECTURAL DRAWINGS ❑ 4 SETS OF STANDARD DETAILS © 4 SETS OF ENERGY CALCULATIONS ❑ 4 SETS OF CONSTRUCTION SPECIFICATIONS ❑ 3. MECHANICAL, 4 COMPLETE SETS. ❑ 4. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS. ® BRIEF PROJECT NARRATIVE: THE SCOPE OF WORK FOR THIS PROJECT WILL INCLUDE ARCHITECTURAL, STRUCTURAL, ELECTRICAL AND MECHANICAL TENANT IMPROVEMENT WORK WITHIN THE 9-120 BUILDING. WORK TO INCLUDE SELECTIVE REMOVAL OF MECHANICAL UNITS, PIPING AND DUCTING, ELECTRICAL CONDUIT, WIRING, PANELS, TRANSFORMERS, LIGHTING, CEILINGS AND WALLS FROM WITHIN THE AREA OF WORK. IT ALSO INCLUDES REINSTALLATION OF WALLS, CEILINGS AND FLOOR COVERINGS WITH MECHANICAL, ELECTRICAL, SYSTEM FURNISHINGS INSTALLATION AND LIMITED STRUCTURAL MODIFICATIONS TO COORDINATE WITH THE NEW LAYOUT. WORK ALSO INCLUDES INSTALLATION OF A NEW PASSENGER ELEVATOR. SUBTITLE TITLE ISSUE FOR PER 06.28.07 VII BY Date: TITLE SHEET 9 -120 FCS — SPL LABS BUILDING 9 -120 FILF COPY Permit No. Plan revicv r is subject to errors and omission, Approval c? c� :ruction documents does not authorize the violation cr' c �y ecccp. code or ordinance. Receipt Of approved Fc;j Cc;.y end condition, is acknotvicdged: City of Tiikwrila BUILDING DMSION Etlo c y . ' rssw} � tse IM3e3 t t0 v, alt t cr p`R?iD! cT TulattiLl i. Wr+J i• NOTE: Revisions veil refit.:n a new p :..: and may include addi'rionai plan review roes. E — — ARCHITECTURAL MASTER COL. DEV. CENTER, WA CURRENT REVISION 1J #16054201 - 02 SHEET JOB NO. DWG NO. GO 16054201 -02 � ® FOR: ;: ec han.'ca/ c ica/ 4 Plumbing p Gas Piping Cray of ; B p i Tys CODE SU v MARY LAND USE CODE CITY OF TUKWILA, WASHINGTON BUILDING CODES * 2003 INTERNATIONAL BUILDING CODE (IBC) * 2003 INTERNATIONAL FIRE CODE (IFC) * 2003 INTERNATIONAL MECHANICAL CODE (IMC) * 2005 NATIONAL ELECTRICAL CODE (NEC) * 2005 UNIFORM PLUMBING CODE (UPC) OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS FIRST FLOOR SECOND FLOOR PENTHOUSE BUILDING HEIGHT STORIES OCCUPANT LOAI): HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC CATEGORY: DESIGN LOADS: ROOF -- SNOW ROOF — LIVE FLOOR — OFFICE (LIVE) FLOOR — DEAD FLOOR — MECHANICAL & STORAGE FLOOR — STAIRS AND CORRIDORS WIND LOADING FIRE EXTINGUISHERS: TOILET ROOM FIXTURE COUNT (2ND FLOOR): TOILETS REQUIRED: MEN = 6 WOMEN = 6 LAVS REQUIRED: MEN = 5 WOMEN = 5 DRINIKING FOUNTAINS: TOTAL REQUIRED = 4 SERVICE SINK: TOTAL REQUIRED = 1 EXITS REQUIRED = 3 EXITS PROVIDED = 4 EXIT WIDTH REQUIRED: EXIT WIDTH PROVIDED: GROUP B, OFFICE TYPE Il —B, NON — COMBUSTIBLE 73,700 S.F. 180,170 S.F. 73,700 S.F. 73,700 S.F. 32,770 S.F. "D" 25 PSF 20 PSF 150 PSF 20 PSF (PARTITION) 125 PSF 150 PSF 80 MPH, EXPOSURE C STAIRS= 148 INCHES DOORS= 111 INCHES STAIRS= 198 INCHES DOORS= 136 INCHES * 2005 STATE OF WASHINGTON ENERGY CODE * STATE OF WASHINGTON BARRIER FREE CODE WITH ICC A117.1 * CITY OF TUKWILA, WA. AMENDMENTS 55 FT. 3 NO CHANGES 'BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT TYPE: AMEREX MODEL 461, RATED 3A:40B:C, 6 LB CAPACITY. MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER = 75 FEET, MAXIMUM FLOOR AREA PER EXTINGUISHER = 11,250 SF TOILETS PROPOSED /PROVIDED: MEN = 8 +4 URINALS EXISTING 2 +1 URINALS NEW 10 +5. URINALS TOTAL WOMEN = 6 EXISTING 3 NEW 9 TOTAL LAVS PROPOSED /PROVIDED: MEN = 8 EXISTING 2 NEW 10 TOTAL WOMEN = 4 EXISTING 2. NEW 6 TOTAL DRINIKING FOUNTAINS PROPOSED /PROVIDED: 1 EXISTING, 2 NEW & 1 KITCHENETTE SINK = 4 TOTAL SERVICE SINK PROPOSED /PROVIDED: TOTAL = 1 RECEIVED CITY OF TUKt. ILA a II II 0 5 71 HIT CEI TtR off- - iii � DLR Group Architecture Engineering Planning REVISION BY APPROVED DR /LS DATE SYM 06.28.07 REVISION BY APPROVED DATE ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DLR GROUP ENGINEER CHECKED APPROVED APPROVED DA1E 12.05.06 SMBOL QR1G 09- 120 —GO DATE COMP NO. Interiors 06.28.07 SfM 8 x 17 ( CPT -1) VCT C PT BUILDING, WALL SECTIONS AND DETAIL REFERENCES k jf ORIG 9-120 FCS SPL LABS REVISION SECTION /DETAIL DESIGNATION SHEET NUMBER WHERE DETAILED SHEET NUMBER REFERENCED FROM INTERIOR ELEVATION REFERENCE SHEET NUMBER WHERE DETAILED SHEET NUMBER REFERENCED FROM P REFERENCE TO DETAIL /ENLARGED PLAN #1 J DETAIL DESIGNATION SHEET NUMBER WHERE DETAILED OF SAME AS SHEET REFERENCED FROM) SECTION /DETAIL DESIGNATION xxxxx ff f SHEET NUMBER WHERE DETAILED SHEET NUMBER REFERENCED FROM NORTH ARROW ELEVATION DATUM OR SPOT ELEVATION CEILING HEIGHT A.F.F. ROOM NAME ROOM NUMBER DOOR NUMBER GRID /GM BUBBLE AND CENTERLINE ITEMS TO BE REMOVED CONSTRUCTION *FLAT NOTE FOR SPECIFIC CONSTRUCTION DIRECTIVE GENERAL 'BOAT" NOTE FOR SPECIFIC OR EXISTING HISTORICAL INFORMATION. WINDOW FRAME TYPE PARTITION/WALL TYPE END WALL GUARD CORNER GUARD FINISH DESIGNATION REVISION CLOUD WITH REVISION LLIILk 'BEAK" FLOOR MAT'L TRANSITION LEGEN D/SY FIRE EXTINGUISHER FIRE EXTINGUISHER & CABINET SUPPLY AIR DIFFUSER RETURN AIR GRILLE FLOURESCENT LIGHT FIXTURE (PENDANT MOUNTED) FLOURESCENT LIGHT FIXTURE (PENDANT MOUNTED) FLOURESCENT LIGHT FIXTURE ON EMERGENCY NIGHT LIGHT (NL) CIRCUIT 0 RECESSED OR PENDANT UGHTNNG FIXTURE o RECESSED OR PENDANT LIGHTING FIXTURE FLOURESCENT LIGHT FIXTURE ON EMERGENCY NIGHT LIGHT (NL) CIRCUIT I 1 WALL SCONCE 1 WALL SCONCE 2 EXIT SIGN (CEILING UNIT) F® EXIT SIGN (WALL MOUNT) BY APPROVED J #16054201 -02 DLR GROUP DR /LS NBOLS DATE REVISION CERAMIC TILE EgR MERIGIED ALUMINUM BRASS, BRONZE, COPPER METAL, STEEL, IRON PLASTER SAND, CEMENT, GROUT PLASTER: GYPSUM WALL BOARD WOOD: FINISH PLYWOOD: SMALL SCALE IMN WALL TYPE: CONCRETE MASONRY (CMU) WALL TYPE: STEEL STUD MATERIAL SYMBOLS EARTH, DIRT, COMPACTED STONE, GRAVEL POROUS FILL BRICK, COMMON CONCRETE INSULATION: BATT, LOOSE FILL, BLANKET EARTH, DIRT, UNDISTURBED INSULATION: RIGID WOOD: ROUGH CONTINUOUS WOOD: INTERRUPTED BLOCKING PLYWOOD: LARGE SCALE WALL TYPE: WOOD STUD WALL TYPE: EXISTING WALL TYPE: REMOVAL WALL TYPE: PARTITION (7'--0' HIGH) WALL TYPE: GLASS 06.28.07 BY APPROVED QATE AB ACP AW AFF AGG AL ALT ALUM ARCH APA APPD APPROX ASTM BTWN BLDG BLKG BOT C CB CC CEM CF CFCI CG CJ CL CLG CLR COL COMP CONC CONN CONST CONE CONTR CT CTSK CY 0, DIA DBL DEMOL DEP DIA DIAG DIM DL DN DS DWG EA EB EF EJ EL ELEV EQ EN EXIST EXP EXT FAS FF FF FF FGR FH FIN FND FOC FOF FOIL FO FRO FT FTG FUT FV GA CRFG GALV GC GI GR GT GWB HDNR HDWD HDWR HG HM HORZ HS HT IBC ID ID IF IN INCL g) LA O E /NQ - AND AT ANCHOR BOLT ACOUSTICAL CEILING PANEL ACOUSTICAL CEILING TILE ADJACENT ABOVE FINISHED FLOOR AGGREGATE ALUMINUM ALTERNATE ALUMINUM ANCHOR, ANCHORAGE AMERICAN PLYWOOD ASSOC. APPROVED APPROXIMATE AMERICAN SOCIETY OF TESTING MATERIALS BETWEEN BUILDING BLOCKING BOTTOM EAST (COORDINATE) EACH EXPANSION BOLT EACH FACE EXPANSION JOINT ELEVATION ELEVATION EQUAL EACH WAY COSTING EXPOSED EXTERIOR FASTEN(ER) FINISHED CEILING FACTORY FINISH FINISHED FLOOR FINISH GRADE FIRE HYDRANT FINISHED) FOUNDATION FACE OF CONCRETE FACE OF FINISH FURNISHED BY OWNER/ INSTALLED BY CONTRACTOR FINISHED OPENING FOR REFERENCE ONLY FOOT FOOTING FUTURE FIELD VERIFY GAGE GLASS FEU REINFORCED GYPSUM GALVANIZED GENERAL CONTRACTOR GALVANIZED IRON GRADE GROUT GYPSUM WALL BOARD HARDENER HARDWOOD HARDWARE HIGH GRADE HOLLOW METAL HORIZONTAL HIGH STRENGTH HEIGHT INTERNATIONAL BLDG. CODE INSIDE DIAMETER INSIDE DIMENSION INSIDE FACE INCH INCLUDED(D) (ING) ARCHITECT I t ALD S ATE i ABBREVIATIONS CHANNEL CATCH BASIN CENTER TO CENTER CEMENT CUBIC FEET CONTRACTOR FURNISHED CONTRACTOR INSTALLED CORNER GUARD CONTROL JOINT CENTER UNE CEILING CLEAR(ANCE) COLUMN COMPRESS(ED) (ION) CONCRETE CONNECTION CONSTRUCTION CONTINUOUS, CONTINUE CONTRACT(OR) CERAMIC TILE COUNTERSUNK CUBIC YARD(S) DIAMETER DOUBLE DEMOLISH, DEMOLITION DEPRESSED DIAMETER DIAGONAL DIMENSION DEAD LOAD DOWN DOWNSPOUT DRAWING COTT KRUSE WASHINGTON ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY JT JOINT K KIP(S) KO KNOCK OUT L LENGTH LB LAG BOLT LEN LENGTH LF LINEAL FEET LL LINE LOAD LWR LOWER MAIL MATERIAL MAX MAXIMUM MB MACHINE BOLT MBR MEMBER MTL METAL MFR MANUFACTURE(R) MIN MINIMUM MISC MISCELLANEOUS MO MASONRY OPENING MT MOUNT(ED) (ING) MTL METAL N NORTH (COORDINATE) NF NEAR FACE NIC NOT IN CONTRACT NO. NUMBER NOM NOMINAL NTS NOT TO SCALE OA 0/C OD OF oFCI OF0I OPG 0PP PAR PARALLEL PCC PRECAST CONCRETE PCF POUNDS PER CUBIC FOOT PERF PERFORATE(D) PERIM PERIMETER PL PLATE PLAM PLASTIC LAMINATE PLYWD PLYWOOD PNL PANEL PREST PRESTRESS(ED) PRE PREFORMED PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT POINT, PAINT PVC POLYVINYL CHLORIDE R RADIUS (CURVATURE) R RISER RB RESILIENT BASE REF REFERENCE, REFER TO RENF REINFORCE(D) (NG) REQ REQUIRE(D) (ING) REV REVISION(S), REVISED RH RIGHT HAND RO ROUGH OPENING S SOUTH (COORDINATE) SECT SECTION SF SQUARE FEET SHT SHEET SIM SIMILAR SQ SQUARE 5S SOLID SURFACING SST STAINLESS STEEL ST STRUCTURAL TEE STD STANDARD STL STEEL STR STRUCTURAL SYM SYMMEIRY,SYMMETRICAL SYS SYSTEM T&B TOP AND BOTTOM T&G TONGUE AND GROOVE TEMP TEMPORARY THK THICK(NESS) TOC TOP OF CURB TOC TOP OF CONCRETE TOL TOLERANCE TOS TOP OF STEEL TS STRUCTURAL TUBE TYP TYPICAL UBC UC UL UN0 UPR VB VAPOR BARRIER VC VINYL COMP. TILE VERT VERTICAL VIF VERIFY IN FIELD W WEST (COORDINATE) W WIDE FLANGE W WIDTH, WIDE WC WOOD WD WITH W/ WITH W/o WITHOUT WWF WELDED WIRE FABRIC NOTE REFER TO THE COLOR AND MATERIAL SCHEDULE, INTERIOR ELEVATIONS AND DOOR SCHEDULE SHEETS FOR ADDITIONAL FINISH AND DESIGNATIONS /ABBREVIATIONS DEPT. OVERALL ON CENTER OUTSIDE DIAMETER OUTSIDE FACE OWNER FURNISHED CONTRACTOR INSTALLED OWNER FURNISHED OWNER INSTALLED OPENING OPPOSITE, OPPOSITE HAND UNIFORM BUILDING CODE UNDER COUNTER UNDERWRITERS' LABEL UNLESS NOTED OTHERWISE UPPER DATE DRAWN DLR GROUP CHECKED L SEELEY ENCWEER CHECKED APPROVED APPROVED DATE 12.5.06 TTMLE ARCHITECTURAL MASTER GENERAL NOTES 1. OBTAIN & POST REQUIRED CONSTRUCTION PERMITS FROM THE CITY OF TUKWILA PRIOR TO COMMENCING CONSTRUCTION. 2. VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE BOEING PROJECT CONSIHUCT1ON MANAGER SHOULD CONDITIONS DIFFER FROM DESIGN DOCUMENTS. 3. THE SCOPE OF WORK INCLUDES ALL WORK WITHIN THE CURRENT REVISION CLOUD(S ON EACH SHEET. IF THERE IS 140 CLOUD ON A SHEET THE ENTIRE SHEET IS IN THE SCOPE OF WORK. INFORMATION OR WORK (WHETHER CLOUDED OR NOT) REFERRED TO FROM WITHIN A CLOUD IS INCLUDED IN THE SCOPE OF WORK (I.E. -- A SECTION OR DETAIL SYMBOL THAT LIES WITHIN A CLOUD ON A PLAN VIEW SHEET IS INCLUDED IN THE SCOPE EVEN WHEN THE ACTUAL SECTION OR DETAIL DRAWN ON THE DETAIL SHEET IS NOT CLOUDED.) 4. KEEP ALL AREAS UNDER CONSTRUCTION CLEAR OF DEBRIS CAUSED BY THIS SCOPE OF WORK. STORE CONSTRUCTION MATERIALS AND EQUIPMENT IN AREA DESIGNATED BY THE BOEING PROJECT CONSTRUCTION MANAGER. 5. VERIFY DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS AND ENSURE THAT THE JOINING OF THE WORK OF VARIOUS TRADES MEETS APPROPRIATELY. BRING DISCREPANCIES ON THE DRAWINGS OR IN SPECIFICATIONS TO THE ATTENTION OF THE BOEING PROJECT CONSTRUCTION MANAGER IMMEDIATELY UPON DISCOVERY. THE CONTRACTOR SHALL ADVISE BOEING, SUMMARIZE THE SITUATION AND PROVIDE RECOMMENDATIONS TO RESOLVING POTENTIAL CONFLICTS PRIOR TO SUBMITTING ANY REQUESTS FOR INFORMATION (RFIs). 6, CONFORM ALL WORK TO APPLICABLE CODES, REGULATIONS AND INDUSTRY STANDARDS. 7. COMPLY WITH THE BOEING PROJECT CONSTRUCTION MANAGER FOR CONSTRUCTION AREA AND SECURITY REGULATIONS. 8. PROVIDE, AS IF DRAWN IN FULL REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS. 9. DIMENSIONS ON DRAWINGS ARE TAKEN TO THE FACE OF MASONRY AND /OR CONCRETE WALLS, METAL STUDS, AND TO THE CENTERLINE OF COLUMNS, UNLESS OTHERWISE NOTED. 10. DOOR OPENINGS ARE 6' FROM ADJACENT WALLS OR CENTERED IN ROOM WALL, UNLESS DIMENSIONED OTHERWISE. 11. PARTITIONS SHALL RUN FULL HEIGHT, FROM FLOOR TO FLOOR ABOVE UNLESS SHOWN OR NOTED OTHERWISE. 12. PLANS WHICH APPEAR AS 'BACKGROUNDS' ON CML, STRUCTURAL, PLUMBING, HVAC, ELECTRICAL DRAWINGS ETC., ARE FOR THE PURPOSE ONLY OF ILLUSTRATING GENERAL PLAN CONFIGURATION. SUCH BACKGROUNDS SHALL NOT BE USED FOR PORTIONS OF THE WORK OTHER THAN THAT PERTAINING TO THE TITLE OF EACH SHEET. REFER TO THE APPROPRIATE SHEET FOR EACH SPECIFIC PORTION OF THE WORK. 13. COORDINATE THE WORK OF ALL TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS IN DETAIL FOR COORDINATION OF SPECIFIC TRADE REQUIREMENTS. COORDINATE ALL ROUGH —IN REQUIREMENTS FOR EQUIPMENT FURNISHED BY CONTRACTOR OR BY OTHERS FOR THIS PROJECT. 14. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS TO THE BOEING PROJECT CONSTRUCTION MANAGER WHENEVER SUCH INSTRUCTIONS ARE REFERENCED IN THE CONSTRUCTION NOTES. 15. CONTRACTOR SHALL COORDINATE WITH THE BOEING PROJECT CONSTRUCTION MANAGER FOR STAGING AREAS WHERE CONTRACTOR MAY STORE SALVAGED MATERIALS TO BE REUSED IN LATER PARTS OF THIS PROJECT AND WHERE MATERIALS TO BE STAGED BY BOEING ARE TO BE LOCATED. 16. SYMBOLS SHOWN ON MATERIALS UST ARE NOT ALWAYS USED IN DRAWINGS. VERIFY EXISTING MATERIAL AND SEE CONSTRUCTION NOTES FOR MATERIAL CALLOUTS. 17. WHERE EXISTING WORK I5 DAMAGED, CUT OR DEFACED AS A RESULT OF DEMOLITION OR PERFORMANCE OF NEW WORK, THE CONTRACTOR IS TO PATCH AND REPAIR THE EXISTING TO MATCH ADJOINING SURFACES. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL BREAK LINES SUCH AS CORNERS, CEILING LINES, TOP OF BASE, CHANGE IN MATERIAL OR SIMILAR. 18. ALL RECESSES LOCATED WITHIN FIRE RATED PARTITIONS SHALL BE CONSTRUCTED TO MAINTAIN REQUIRED FIRE RATING OF THE PARTITION. 19. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE THE FINAL LOCATIONS OF MECHANICAL AND ELECTRICAL COMPONENTS. SEE THE REELECTED CEILING PLANS FOR LOCATIONS OF ITEMS IN THE CEILING; SEE DISCIPLINE SHEETS FOR ALL INFORMATION ABOUT THE MECHANICAL AND ELECTRICAL COMPONENTS INDICATED ON ARCHITECTURAL REFLECTED CEILING PLANS. 20. PROVIDE CLOSURE, MEETING THE REQUIREMENTS OF GOVERNING FIRE AUTHORITIES, BETWEEN ALL FIRE RATED FLOORS, SHAFTS AND BUILDING PARTITIONS AND ALL PENETRATING DUCTS, PIPES, CONDUIT, MECHANICAL, ELECTRICAL AND OTHER ITEMS. 21. THE CONTRACTOR IS RESPONSIBLE FOR REVIEW OF THE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR CUTTING AND PATCHING WORK WITHIN THE BUILDING, BEYOND THE LIMITS OF THE ARCHITECTURAL DRAWINGS. 22. AT METAL STUD PARTITIONS, STUDS ARE TO EXTEND FROM FLOOR TO FLOOR U.N.0.. WHERE THEY CANNOT DO SO, DUE TO INTERFERENCE WITH NEW OR EXISTING DUCTS, PIPING, ETC., PROVIDE BRACING TO STRUCTURE ABOVE TO PROVIDE FOR EQUIVALENT SUPPORT OF PARTITION; SUBMIT EQUIVALENT SUPPORT METHOD TO ARCHITECT FOR REVIEW. ALL FIRE RATED PARTITIONS SHALL BE CONSTRUCTED TO MAINTAIN THEIR RATING FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE, U.N.O. 23. PROVIDE ACCESS DOORS AS INDICATED OR AS NECESSARY AND VERIFY WITH MECHANICAL AND ELECTRICAL SUBCONTRACTORS EXACT LOCATIONS OF ACCESS REQUIRED BY THEIR WORK. ACCESS MUST BE PROVIDED FOR ALL CONCEALED VALVES, DAMPER CONTROLS, FIRE DAMPER LINKAGES, CONCEALED JUNCTION BOXES, AND ELECTRICAL DEVICES OR ACCESSORIES. LOCATIONS AND SIZES OF EXPOSED ACCESS DOORS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW PRIOR TO INSTALLATION OF THE MECHANICAL AND ELECTRICAL EQUIPMENT. 24. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE WITH ALL SAFETY CODES, REGUALTIONS AND BOEING REQUIREMENTS. 25. THE CONTRACTOR SHALL RETAIN A FIRE PROTECTION ENGINEER LICENSED IN THE STATE OF WASHINGTON TO DETERMINE /DESIGN THE MODIFIED FIRE SPRINKLER SYSTEM LAYOUT WITHIN THE AREA OF WORK. SAID ENGINEER SHALL STAMP, SEAL AND CERTIFY THAT HIS /HER DESIGN IS IN COMPLIANCE W /ALL APPLICABLE CODES AND REGULATIONS. CONTRACTOR SHALL COORDINATE ALL NECESSARY MODIFICATIONS AS A RESULT OF SAID ENGINEER'S DESIGN. 26. THE CONTRACTOR SHALL RETAIN AN ELEVATOR CONSULTANT TO CERTIFY THAT THE ELEVATOR CAR, EQUIPMENT ROOM, EQUIPMENT LAYOUT AND HYDRAULIC /ELECTRICAL ROUTING FULLY MEETS STATE OF WASHINGTON CODES AND COMPLIANCE. FULLY COORDINATE WITH ARCHITECT PRIOR TO FABRICATION AND INSTALLATION. 27. AT LOCATIONS WHERE STRUCTURE, PIPING, DUCTWORK, CABLETRAY, OR CONDUIT PENETRATES WALLS AND ARE EXPOSED TO VIEW, CONTRACTOR SHALL COPE AS CLOSELY AS POSSIBLE TO THE MEMBER AND INSTALL CONTINUOUS CAULKING AROUND MEMBER AND PAINT OR PROVIDE ESCUTCHEONS MATCHING WALL COLOR AT PENETRATIONS. ISSUE FOR PERMIT 06.28.07 SUBTITLE MATERIALS, ABBREVIATIONS & GEN'L NOTES 9 -120 FCS — SPL LABS BUILDING 9 -120 %D1-1K DEN/. CENTER, WA � DLR Group CURRENT REVISION J#1 6054201 —02 SHEET Architecture Engineering Planning G1 JOB NO. 150680-01 DWG NO. SYMBOLO R IC 09- 120 -01 RECEIVED CITY OF TUKWILA JUL 0 5 ?007 Ir' f s I CE.N; I r a DATE COMP NO. 06.28.07 Interiors SYM ORIG INCLUDED IN SET DRAWING NO. • 09-120-GO ® 09-- -120 -G1 • 09- 120 -G2 O 09-120-1A1 OR O 09- 120 -2A1OR O 09- 120 -2A11R O 09- 120 -3A1OR O 09-120-3A11R O 09- 120- 1A280R O 09- 120- 2A280R O 09 -120- 2A281R O 09- 120 -2M1OR O 09-120-2M11R O 09- 120 -2M60R O 09- 120 -2M61R 0 09- 120- 2M260R O 09- 120- 2M261R O 09- 120- 1M450R O 09- 120- 2M450R • 09- 120 -1E10R O 09-- 120-- -2E1OR O 09- 120 -2E11R • 09- 120 -1E60R O 09- 120 -E4AR • 09-120-2A03 • 09- 120 -2A04 • 09- 120 -1A10 • 09- 120 -2A10 • 09-120-2A11 O 09-120-3A10 • 09- 120 -RFA11 • 09- 120 -1A280 • 09- 120 -2A280 • 09- 120 -2A281 • 09-120-1A350 • 09- 120 -2A350 • 09- 120 -2A351 • 09- 120 -A200 • 09- 120 -A201 • 09- 120 -A350 • 09-120-A351 • 09- 120 -A352 • 09-120-A370 • 09- 120 -A450 • 09-120-A507 • 09-120-A508 SHEET NO. GO G1 G2 1A1 OR 2A1 OR 2A11R 3A1 OR GENERAL \D DRAWING SUBTITLE TITLE SHEET - VOLUME 1 ORIG 06.28.07 LEGEND, MATERIALS, ABBREVIATIONS & GENT NOTES ORIG 06.28.07 INDEX OF DRAWINGS ORIG 06.28.07 ARCHITECTURAL REMOVAL FIRST FLOOR REMOVAL PLAN SECOND FLOOR REMOVAL PLAN SECOND FLOOR REMOVAL PLAN THIRD FLOOR /ROOF REMOVAL PLAN 3A1IR THIRD FLOOR /ROOF REMOVAL PLAN 1A280R FIRST FLOOR REFLECTED CEILING REMOVAL PLAN 2A280R SECOND FLOOR REFLECTED CEILING REMOVAL PLAN 2A281R SECOND FLOOR REFLECTED CEILING REMOVAL PLAN 2M1OR SECOND FLOOR DUCTWORK REMOVAL PLAN 2M11R SECOND FLOOR DUCTWORK REMOVAL PLAN 2M60R SECOND FLOOR HVAC PIPING REMOVAL PLAN 2M61R SECOND FLOOR HVAC PIPING REMOVAL PLAN 2M260R SECOND FLOOR FIRE SPRINKLER REMOVAL PLAN ORIG 06.07.07 2M261R SECOND FLOOR FIRE SPRINKLER REMOVAL PLAN ORIG 06.07.07 1M450R ENLARGED PLUMBING REMOVAL PLANS ORIG 06.07.07 2M450R ENLARGED PLUMBING REMOVAL PLANS ORIG 06.07.07 1E1OR FIRST FLOOR UGHT1NG PLAN - REMOVAL 2E10R SECOND FLOOR LIGHTING PLAN - REMOVAL 2E11R SECOND FLOOR LIGHTING PLAN - REMOVAL 1E6OR FIRST FLOOR 208Y/120V POWER PLAN - REMOVAL E4AR ONE -LINE DIAGRAM - REMOVAL 2A03 SECOND FLOOR COMPOSITE /EXIT PLAN ORIG 06.28.07 2A04 SECOND FLOOR COMPOSITE REFLECTED CEILING PLAN ORIG 06.28.07 1A10 FIRST FLOOR PLAN 2A10 SECOND FLOOR PLAN 2A11 SECOND FLOOR PLAN 3A10 THIRD FLOOR / ROOF PLAN RFA11 ROOF PLAN 1A280 2A280 2A281 1A350 2A350 2A351 A200 A201 A350 A351 A352 MECHANICAL REMOVAL ELECTRICAL REMOVAL ARCHITECTURAL FIRST FLOOR REFLECTED CEILING PLAN SECOND FLOOR REFLECTED CEILING PLAN SECOND FLOOR REFLECTED CEILING PLAN FIRST FLOOR FINISH PLAN SECOND FLOOR FINISH PLAN SECOND FLOOR FINISH PLAN A507 MISCELLANEOUS SECTIONS AND DETAILS A508 CASEWORK SECTIONS AND DETAILS X OH DRAW REV DATE ORIG 06.07.07 ORIG 06.07.07 ORIG 06.07.07 ORIG 06.07.07 ORIG 06.28.07 ORIG 06.07.07 ORIG 06.07.07 ORIG 06.28.07 ORIG 06.07.07 06.07.07 06.07.07 06.07.07 06.07.07 06.07.07 06.07.07 06.07.07 06.07.07 06.28.07 06.28.07 06.28.07 06.07.07 06.28.07 ORIG 06.28.07 A 06.28.07 A 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 PARTITION TYPES, SECTIONS, NOTES & DETAILS ORIG 06.28.07 WALL -& - ELEVATOR SECTIONS ORIG 06.28.07 DOOR AND HARDWARE SCHEDULES & FRAME TYPES ORIG 06.28.07 DOOR AND WINDOW DETAILS ORIG 06.28.07 COLOR AND MATERIAL SCHEDULE ORIG 06.28.07 A370 INTERIOR ELEVATIONS ORIG 06.28.07 A450 ENLARGED TOILET ROOM & ELEVATOR PLANS ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 INCLUDED IN SET DRAWING N0. SHEET NO. • 09-- 120 --S2A S2A • 09- 120 -S2B S2B • 09 -120 -1 S10 1510 • 09- 120 -2510 2510 • 09-- 120 -2S11 2511 O 09- 120 -3510 • 09 -120 -3511 • 09-120-S508 3510 3511 S508 • 09- 120 -M2A M2A • 09-120-M2B M2B • 09- 120 -1M10 1M10 • 09- 120 -2M10 2M10 • 09- 120 --2M11 2M11 • 09- 120 -3M10 3M10 • 09-120-3M11 3M11 • 09- 120 -2M60 2M60 • 09-120-2M61 2M61 • 09- 120- -1M110 1M110 • 09- 120 -2M110 2M110 • 09- 120 -2M260 2M260 • 09- 120 -2M261 2M261 • 09- 120 -2M262 2M262 • 09- 120 -2M263 2M263 • 09- 120 -3M261 3M261 • 09-120-1M450 1M450 • 09- 120 -2M450 2M450 • 09- 120 -RFM4 RFM4 • 09- 120 -M310 M310 • 09- 120 -M311 M311 • 09-120-M530 M530 • 09- 120 -M531 M531 • 09- 120 --M532 M532 • 09- 120 -M533 M533 • 09- 120 -1 E10 1E10 • 09- 120 -2E10 2E10 • 09- 120 -2E11 2E11 • 09- 120 -2E13 2E13 • 09-120-1E60 • 1E60 • 09- 120 -2E60 2E60 • 09- 120 -2E61 2E61 • 09- 120 -3E61 3E61 • 09- 120 -2E110 2E110 • 09- 120 -2E111 2E111 • 09- 120 -2E112 O 09- 120 -3E110 • 09- 120 -3E111 2E112 3E110 3E111 • 09- 120 -2E360 2E360 • 09- 120 -2E361 2E361 • 09- 120 -E4A E4A • 09- 120 -E4C E4C • 09- 120 -E501 [501 GS DRAWING SUBTITLE STRUCTURAL STRUCTURAL GENERAL NOTES STRUCTURAL GENERAL NOTES. FIRST FLOOR FRAMING PLAN SECOND FLOOR FRAMING PLAN SECOND FLOOR FRAMING PLAN THIRD FLOOR FRAMING PLAN THIRD FLOOR FRAMING PLAN STRUCTURAL DETAILS VIECHANICAL MECHANICAL SCHEDULES MECHANICAL SCHEDULES FIRST FLOOR DUCTWORK PLAN SECOND FLOOR DUCTWORK PLAN SECOND FLOOR DUCTWORK PLAN THIRD FLOOR DUCTWORK PLAN THIRD FLOOR DUCTWORK PLAN SECOND FLOOR HVAC PIPING PLAN SECOND FLOOR HVAC PIPING PLAN FIRST FLOOR PLUMBING PLAN SECOND FLOOR PLUMBING PLAN SECOND FLOOR FIRE SPRINKLER PLAN SECOND FLOOR FIRE SPRINKLER PLAN SECOND FLOOR FIRE SPRINKLER PLAN SECOND FLOOR FIRE SPRINKLER PLAN THIRD FLOOR / ROOF FIRE SPRINKLER PLAN ENLARGED PLUMBING PLANS ENLARGED PLUMBING PLANS CHILLED WATER SYSTEMS OVERFLOW CONTROLS DIAGRAM SEQUENCE OF OPERATION HVAC DETAILS PIPING DETAILS AIR HANDLER UNIT DETAILS SECTIONS AND DETAILS ELECTRICAL FIRST FLOOR LIGHTING PLAN SECOND FLOOR LIGHTING PLAN SECOND FLOOR LIGHTING PLAN SECOND FLOOR LIGHTING PLAN FIRST FLOOR 208Y/120V POWER PLAN SECOND FLOOR 208Y/120V POWER PLAN SECOND FLOOR 208Y/120V POWER PLAN ROOF 208Y/120V POWER PLAN SECOND FLOOR 480Y/277V POWER PLAN SECOND FLOOR 480Y/277V POWER PLAN SECOND FLOOR 480Y/277V POWER PLAN ROOF 480Y/277V POWER PLAN ROOF 480Y/277V POWER PLAN SECOND FLOOR TELECOMMUNICATIONS PLAN SECOND FLOOR TELECOMMUNICATIONS PLAN ONE-LINE DIAGRAM ONE -LINE DIAGRAM DETAILS REV DATE ORIG 06.28.07 ORIG 06.28.07 A 06.28.07 A 06.28.07 A 06.28.07 ORIG 06.07.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06 28.07 ORIG 06.28,07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.07.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 ORIG 06.28.07 PROVED SUBTITLE TITLE ISSUE FOR PERMIT 06.28.07 ARCHITECTURAL MASTER INDEX OF DRAWINGS 9 -120 - FCS SPL LABS BUILDING 9 -120 PREL ORIG A ISSUE LEGEND NOT YET ISSUED PREVIOUSLY ISSUED FOR CONSTRUCTION PREVIOUSLY ISSUED, BUT NOT IN THIS ISSUE INCLUDED IN THIS ISSUE PRELIMINARY ISSUE FOR REVIEW OR INFORMATION ONLY NOT FOR CONSTRUCTION ORIGINAL ISSUE FOR PERMIT, BID, PROCUREMENT OR CONSTRUCTION DRAWING REVISION - SEE SPECIFIC DRAWING FOR NATURE OF REVISION DEV. CENTER, WA r CO. C 00 i �v , 1\ \ _ .. _\_.3 \.5t, v_c. .- -- 0 9 -120 - ICS SPL LABS REVISION BY J #16054201 -02 DLR GROUP APPROVED DR /LS DATE 06.28.07 SYM REVISION BY APPROVED DATE DRAWN DLR GROUP CHECKED ENGINEER CHECKED APPROVED AP DATE 12.05.06 CURRENT REVISION J #16054201 - 02 SHEET JOB NO. DWG NO. DLR Group Architecture Engineering Planning Interiors G2 16054201-02 SYMBOL R I IJ 09- 120 -G2 RECEIVED CITY OF TU KWILA JUL 0 5 7007 DATE COMP NO. r = 06.28.07 1 f ( I—� r T tt STATIC TEST AREA 108 1 FIRST FLOOR PLUIVBI \G PAN SCALE: 1 /8 "= 1' -0" EXIST. NW CORRIDOR 1 1_ 1 1 ( P - \, KT ) OFFICE ELF / R 1 EQUIP. LITZ!! .1 .� • a - J � II Lvi J io00 ' MEN TOILET AREA #2 L EXPERIMENTAL MECHANICS 122 LASER ROOM #1 123 1 4 1 IMAGE PROCESSING 1 I 127 ■ i 1 I 1--- i I 1 , ■ .. a. — .. — .. LASER ROOM #2 129 1,M450 JANITOR OFFICE 128 1M450 CORRIDOR 126 SPAT ROOM 130 1 1 ■ 1121 1 � ■ EXIST. CORRIpR 137 ■ LOAD ROOM 132 ► r ;14 - 0 ACOUSTIC 1-- i -1 EMISSION ! i x 131 < I xo PHOTO - ELASTIC TEST 133 0 ISSUED FOR PERMIT SET 06.28.07 LEG .. D GENERAL NOTES REFERENCE DRAW' \1GS CONSTRUCTION \ OTES RECEIVED ILA CITY JUL 0 5 7001 VEriMET C EN I LR 1 M110f//,1 1M111 1M112 1M113 8' 4' 0 4' 8' 16' Mr= SCALE: 1/8”=1'-0" AF 4IMEFA NGINEERS N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 - 1625 206 623 0717 Fax 206 624 3775 9 -120 RENOVATION 416054201 -02 COFFMAN M. SOTURA 06.28.07 SYM ORIC REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE p rzrisarArAwe) ACCEPTABIUTY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. DATE SUBTITLE FIRST FLOOR PLUMBING PLAN TITLE 9 -120 RENOVATION ARCHITECTURAL MASTER BUILDING 9-120 COL A -F/1 -5 DEV. CENTER, WA DRAWN COFFMAN CHECKED M. SOTURA ENGINEER CHECKED APPROVED APPROVED DATE 05.23.07 05.23.07 CURRENT REVISION J #16054201 --- 02 SHEET DATE 06.28.07 SYMBOLO R I G 1M110 JOB NO. 16054201-02 COMP NO. DWG NO. 09-- 120- -1M110 SYM ORIG 9 -120 RENOVATION 0 REVISION ERIE�TAI� M-CLIA 122 416054201-02 Eft COFFMAN 3"W UP TO i ( f I i i 1 i __.,\ 1 {-- i F \.,, di . ' 1 LET AREA 1, 1 APPROVED L. } M. SOTURA L v DATE 06.28.07 \C2/ 3 "W N/zi 3/4" 1 2"V UP l 1 3 "W UP 0 1 ST FLOOR TOILET ROOM DRAINAGE SCALE: 1/4"= 1'--0" REVISION JAN 4 "W 1 -1/2"W UP 3 "W TIE -IN 4"WASTE TACK ( 4"W TIE-IN TO (E) 4"WASTE STACK TOR 4"W UP 11'4�IAG 1M110 1M450 I!ZZ /1 2 "V UP SRO E SSI NC 1 7 \T 2"W UP BY APPROVED 2"W UP EXIST. CORRID 137 2 "W UP \ UP DATE 112 Air47AW© r LEV R EQUIP. !L EXPIRES 1/10/09 FXPLR1ME N lAi- MECHANICS 122 1 ST FLOOR TOILET RCOM DOVESTIC WATER SCALE: 1/4' = 1' -0" ACCEPTABILITY 11-115 DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN NECKED M. SOTURA ENGINEER CHECKED APPROVED APPROVED 1_ I i n CW 2 "HW 1 /2 "HWC DATE 05.23.07 05.23.07 TITLE 3"CW UP 1 2 "HW UP 1/21-IWC UP SUBTITLE HWI 1M110 1M450 PROCISS!R 127 ARCHITECTURAL MASTER COL. C -D/2 -4 XXIST, CORRI 137 C gibT ISSUED FOR PERMIT SET 06.28.07 ENLARGED TOILET ROOM PLUMBING PLANS 9 -120 RENOVATION BUILDING 9 -120 DEV. CENTER, WA LEGEN V VENT W WASTE TP TRAP PRIMING PIPE TP TRAP PRIMING PIPE 0 0 FCO o-I- PIPE TEE, DOWN VENT THROUGH ROOF FLOOR CLEANOUT PIPE ELBOW, TURNED UP OR TOWARD PIPE ELBOW TURNED DOWN OR AWAY POINT OF CONNECTION C CONDENSATE DRAIN LINE CW DOMESTIC COLD WATER HW DOMESTIC HOT WATER SUPPLY HWC DOMESTIC HOT WATER CIRCULATING PW PROCESS WATER I0 I 0 R I BUTTERFLY VALVE VENT THROUGH ROOF WATER HAMMER ARRESTOR BALL VALVE, OPEN 0 PIPE ELBOW, TURNED UP OR TOWARD c -4 - - -- PIPE ELBOW TURNED DOWN OR AWAY GE\ERAL NOTES REFERENCE DRAWI \ GS CONSTRUCTION NOTES 4" VENT TIE -IN TO EXISTING WASTE STACK. CAP EXISTING 3 "CW BELOW FLOOR DOWNSTREAM OF EXISTING SHUT -OFF VALVE. CAP EXISTING PLUMBING SERVICES AS REQUIRED TO MAINTAIN FIRST FLOOR PLUMBING FIXTURES OPERATIONAL. PLUMBING SERVICES TIE -IN AT THIS LOCATION. CONDENSATE TIE -IN TO SINK TAILPIECE. JOB NO. DWG NO. jjj % /iJ 1M451 1M452 1M453 8 CURRENT REVISION 416054201 SHEET KEY PLAN SCALE NONE 4' 0 4' SCALE: 1/8"=1' -0" RECEIVED CITY OF TuKW'LA C�FFIIII�N JUL 0 5 7F^? N G I N E R S '�ilili T ;.€�i;l 1601 900 Seattle, Washington Fifth Avenue 98101 -1625 Suite 206 623 0717 Fax 206 624 3775 1M45O SYMBOL DATE 16054201 -02 09- 120 -1M450 COMP NO. 06.28.07 16' EXIST. 3" L 1 1 1 T 1 i 1 f T IT EXIST. 3 "W EXIST. 2"V UP 4"V DN 31'W DN TIE —IN TO EXIST. 3"W L T EXIST. 1 -1/2"W UP TIE —IN TO EXIST. 1-1/2"W P-8 2ND FLOCR TOILET ROOM — SCALE: 1/4"= 1' -0" T � I DRAINAGE 2M110 2M450 P -3 H J L r EXIST. 1 "CW & 1 "HW UP• EXIST. 3 /4 "CW UP TO HOSE BIBB 1 j HW HW T i i T i i T T T - f 1 1 ! I TIE —IN TO — EXIST. 2"CW UP 3/4" P -8 1 .-1 /2„ 2 " 3 5 0 : 3 L 3/4" CW 2ND FLOOR TOILET ROOM - DOMESTIC WATER SCALE: 1/4' P -6 2M110 2M450 f P -3 _ R EWEP�NCE APPROVE COMPLIANC R SlL1 City Of Tukwila N ILDIN DIVISION P -3 L_W P -3 P -7 ISSUED FOR PERMIT SET 06.28.07 LEGEND - C CONDENSATE RETURN (GRAVITY) V VENT - W WASTE TP TP O 0 FCO 0 -- 101 CW DOMESTIC COLD WATER - HW DOMESTIC HOT WATER SUPPLY HWC DOMESTIC HOT WATER CIRCULATING PW BUTTERFLY VALVE O VENT THROUGH ROOF WATER HAMMER ARRESTOR BALL VALVE, OPEN 04— PIPE ELBOW, TURNED UP OR TOWARD c—l- -- PIPE ELBOW TURNED DOWN OR AWAY CONSTRUCTIO TRAP PRIMING PIPE TRAP PRIMING PIPE PROCESS WATER REVISION INDICATOR GE\ ERAL NOTES PIPE TEE, DOWN VENT THROUGH ROOF FLOOR CLEAN OUT PIPE ELBOW, TURNED UP OR TOWARD PIPE ELBOW TURNED DOWN OR AWAY POINT OF CONNECTION REFERENCE DRAWINGS MOTES 1/2" DOWN TO FLOOR DRAIN TRAP PRIMERS. HOT WATER SUPPLY ELEVATION TO BE WITHIN 6" OF WALL PENETRATION TO FIXTURE SUPPLY. 1 /2 "REDUCED PRESSURE BACKFLOW PREVENTER MOUNTED ON WALL FOR AHU HUMIDIFIER. ROUTE DRAIN TO OVER JANITOR SINK. ROUTE 1 /2 "CW TO HUMIDIFIER SECTION AT AHRG4 LOCATED ON ROOF. RECEIVED CITY OF TUKWILA PI_ 057007 PERMIT CENTER 2M451 2M453 8' 4' 0 4' 8' 16' SCALE: 1/8"---1'-0" COFFMAN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 SYM SYM ORIG 9-120 RENOVATION REVISION J #16054201 -02 BY COFFMAN APPROVED M. SOTURA DATE 06.28.07 REVISION BY APPROVED DATE ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN CHECKED_ M. SOTURA ENGINEER CHECKED APPROVED APPROVED DATE 05.23.07 05.23.07 SUBTTFLE TITLE ENLARGED TOILET ROOM PLUMBING PLANS 9 -120 RENOVATION BUILDING 9 -120 ARCHITECTURAL MASTER COL A —F/1 -5 DEV. CENTER, WA CURRENT REVISION J# 16054201 - 02 SHEET 2M450 JOB NO. 16054201 -02 'ORIG DATE 06.28.07 COMP NO, DWG NO. 09- -120 -2M450