HomeMy WebLinkAboutPermit PG07-207 - BAHAMA BREEZEBAHAMA BREEZE
15700 SOUTHCENTER PY
EXPIRED 02 -04-08
PGO7-207
Parcel No.:
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
Contact Person:
Name:
Address:
doc: UPC -10/06
Cityboef Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
1157200292
15700 SOUTHCENTER PY TUKW
BAHAMA BREEZE
15700 SOUTHCENTER PY , TUKWILA WA
WEA SOUTHCENTER LLC
11601 WILSHIRE BLVD , LOS ANGELES CA
CAROL RANDALL
12601 132 AV NE , KIRKLAND WA
Contractor:
Name: FAST WATER HEAT COMPANY
Address: 12601 132ND AVE NE , KIRKLAND WA
Contractor License No: FASTWWH948BC
DESCRIPTION OF WORK:
REMOVE/REPLACE GAS WATER HEATER
Plumbing
Bathtub or combination bath/shower 0
Bidet 0
Clothes washer, domestic 0
Dental unit, cuspidor 0
Dishwasher, domestic, with independent drain
Drinking fountain or water cooler (per head)
Food -waste grinder, commercial
Floor drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
PLUMBING /GAS PIPING PERMIT
FIXTURE TYPE AND OUANTITY
* *continued on next page **
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 800 454 -8955
Phone: (425)814 -3124
Expiration Date: 01/03/2008
Uniform Plumbing Code Edition: 2006
2006
Value of Plumbing /Gas Piping: $799.00
Fees Collected: $88.00 International Fuel Gas Code Edition:
PG07 -207
08/08/2007
02/04/2008
Plumbing (cont.)
Building sewer and each trailer park sewer 0
Rain water system - per drain (inside bldg) 0
Water heater and/or vent 1
Industrial waste treatment interceptor, including
0 its trap and vent, except for kitchen type
0 grease interceptors 0
0 Repair or alteration of water piping and/or water
0 treatment equipment 0
0 Repair or alteration of drainage or vent piping 0
0 Medical gas piping system serving (1 -5)
0 inlets /outlets for a specific gas 0
0 Medical gas piping (6 +) inlets /outlets 0
0 Gas Piping
0 Gas piping outlets (0 -5) 0
0 Gas piping outlets (6 +) 0
PG07 -207 Printed: 08-08 -2007
Permit Center Authorized Signature
I hereby certify that I have read and x
governing this work will be complie
Signature:
Print Name:
doc: UPC -10/06
City orTukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
The granting of this permit do - s not • esume to give authority to violate or cancel the provisions of any other state or local laws regulating •
construction or the perfo ;� e o • rk I : • uthppzed to sign and obtain this plumbing /gas piping permit.
Date: f " r 9 7
Permit Number: PG07 -207
Issue Date: 08/08/2007
Permit Expires On: 02/04/2008
Date: O$
n ed this permit and know the same to be true and correct. All provisions of law and ordinances
, whether specified herein or not.
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PG07 -207 Printed: 08-08 -2007
Parcel No.: 1157200292
Address:
Suite No:
Tenant:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
15700 SOUTECENTER PY TUICW
BAHAMA BREEZE
1: ** *PLUMBING AND GAS PIPING * **
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
PG07 -207
ISSUED
08/08/2007
08/08/2007
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire-resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
doc: Cond -10/06
* *continued on next page **
PG07 -207 Printed: 08 -08 -2007
Signature:
Print Name:
doc: Cond -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
" Pu rric4 Le/
Date: O ery 7
PG07 -207 Printed: 08 -08 -2007
C King Co Assessor's Tax No.: \ S 7 a bO a 9 � .
Site Address: (� O Sock.C' C enjf L Suite Number: Floor:
New Tenant: ❑ .... Yes ErNo
Tenant Name:
Contact Person:
E -Mail Address:
Company Name:
Mailing Address:
CITY OF TUKWI
Community Developmenrnepartment
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
q:1\permits plus \icc changes \permit application (7 -2004)
Revised: 68-05
bh
�1rlri` ' re ez,�
Property Owners Name: SO
Mailing Address:
CONTACT PERSON
Name:
Mailing Address:
City
E -Mail Address: Fax Number:
.........
GENERAL CONTRACTO INFORMATION - (Mechanical Contractor .information on back page)
Company Name: f S W
Mailing Address: 1. &(96 t rte) 1 AYE klek-A611d (...07"t ?o3L
Oct la) 10
0 .-[a
City State Zip
Day Telephone: it a6 q - gls
Fax Number: "GY�.'S — V P4 - ! p Si (
Expiration Date: L (3 lo T
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
Contractor Registration Number: ��#tj)u)14 q qq
H',ARCHITECr OF RECORD
All plans must be wet stamped by Architect of Recor
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
ENGINEER OFRECORD — A ll plans must, be wet s t a mped by Engineer'of Record
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number
Page 1
City
State
Day Telephone:
State
City
Day Telephone:
Fax Number:
State
State
Zip
Zip
Zip
Zip
Unit Type:
Qty .
.Unit Type:
Qty
Unit. Type:
Qty
Boiler /Compressor:
Qty
BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace >100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Water Heater
t
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig/Cooling
System
Incinerator - Domestic
Emergency
Generator
Air Handling Unit
<10,000 CFM
Incinerator — Comm/Ind
Other Mechanical
Equipment
1
MECHANICAL PERMIT INF(*IATION 206- 4313670
•
MECHANICAL CONTRACTOR INFORMATION
Company Name:
Mailing Address:
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
i
Valuation of Project (contractor's bid price): $ 1 1 I
Scope of Work (please provide detailed information): L/€t NY100 t� lQ� -� 8Q s Wecteir
Use: Residential: New .... ❑ Replacement ❑
Commercial: New ....El Replacement [Ii
Fuel Type: Electric ❑ Gas ....E Other:
Indicate type of mechanical work being installed and the quantity below:
PERMIT APPLICATION NOTES = Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested
in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING 0 ' ` R OR
Signature:
Print Name:
Mailing Address:
aCob�
Date Application Accepted:
Date Application Expires:
q: \\permits plus\icc changes\permit application (7 -2004)
Revised. 6-8 -05
bh
GENC�
Page 4
City State Zip
.Date: O 60 (07
Day Telephone: U
Kt lah (vim q3(
City State Zip
Staff Initials:
Receipt No.: R07 -01627
Initials: JEM
User ID: 1165
Payee: FWH ACQUISITION COMPANY LLC
ACCOUNT ITEM LIST:
Description
PLUMBING - NONRES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 1157200292 Permit Number: PG07 -207
Address: 15700 SOUTHCENTER PY TUICW Status: PENDING
Suite No: Applied Date: 08/08/2007
Applicant: BAHAMA BREEZE Issue Date:
TRANSACTION LIST:
Type Method Description Amount
Payment Check 3534 88.00
Account Code Current Pmts
000/322.100 88.00
Total: $88.00
Payment Amount: $88.00
Payment Date: 08/08/2007 11:01 AM
Balance: $0.00
1256 08/08 9710 TOTAL 88.00
doc: Receiot -06 Printed: 08 -08 -2007
01 -08 -2008
CAROL RANDALL
12601 132 AV NE
KIRKLAND WA 98034
Dear Permit Holder:
Thank you for your cooperation in this matter.
Sincerely,
V\ A4
er Marshall
Permit Technician
xc: Permit File No. PG07 -207
City of Tukwila
RE: Permit No. PG07 -207
15700 SOUTHCENTER PY TUKW
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the
Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work
authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does
allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests
must be in writinx and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from
being taken.
In the event you do not call for the above inspection and receive an extension prior to 02/04/2008 , your permit will become null and
void and any further work on the project will require a new permit application and associated fees.
Ann C....tA...,..t... D....1...n,..A C..Jt.. 41 nn • oh Is..Mi.r. OR1RR • Dhnnv. 9MA- 421 -2f7/1 • Pot MA- 421.2Atic
License Information
License
FASTWWH948BC
Licensee Name
FAST WATER HEATER COMPANY
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
602564544
Ind. Ins. Account Id
5380601
Business Type
LIMITED LIABILITY COMPANY
Address 1
12601 132ND AVE NE
Address 2
City
KIRKLAND
County
KING
State
WA
Zip
98034
Phone
4258143124
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
1/3/2006
Expiration Date
1/3/2008
Suspend Date
Separation Date
Parent Company
FWH ACQUISITION COMPANY LLC
Previous License
FASTWHCO52DF
Next License
Associated License
Business Owner Information
Name
Role
Effective
Date
Expiration
Date
JORDAN, JEFF
PARTNER/MEMBER
01/03/2006
HANLEYBROWN,
JASON
PARTNER/MEMBER
01/03/2006
Look Up a Contractor, Electricn or Plumber License Detail Page 1 of 2
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
DEVELOPERS
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= FASTWWH948BC 08/08/2007