Loading...
HomeMy WebLinkAboutPermit PG07-215 - STARBUCKSSTARBUCKS 17100 SOUTHCENTER PY STE 110 PGO7-2 15 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Cit“ Tukwila 2623049081 17100 SOUTHCENTER PY TUKW STARBUCKS 17100 SOUTHCENTER PY, SUITE 110 , TUKWILA WA WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE WA GEORGE FEARS 1439 KAISER RD SW , OLYMPIA WA Contractor: Name: BATHROOM INC, THE Address: 1439 KAISER RD SW , OLYMPIA WA Contractor License No: BATHRI *042JA Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet doc: UPC -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us FIXTURE TYPE AND OUANTITY * * continued on next page ** PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 360 -701 -1210 Phone: 360 866 -4041 Expiration Date: 04/21/2008 DESCRIPTION OF WORK: PLUMBING FOR STARBUCKS RESTAURANT COFFEE SHOP - INCLUDING DISHWASHER, TRIPLE SINK HAND SINKS, FLOOR SINKS, HOT WATER TANK, 2 ADA RESTROOMS. PGO7 -215 09/10/2007 03/08/2008 Value of Plumbing /Gas Piping: $30,000.00 Uniform Plumbing Code Edition: 2006 Fees Collected: $340.00 International Fuel Gas Code Edition: 2006 Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 1 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 1 Repair or alteration of water piping and/or water 1 treatment equipment 1 0 Repair or alteration of drainage or vent piping 1 2 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 6 Medical gas piping (6 +) inlets /outlets 0 5 Gas Piping 0 Gas piping outlets (0 -5) 0 2 Gas piping outlets (6 +) 0 PG07 -215 Printed: 09 -10 -2007 Permit Center Authorized Signature: Signature: Print Name: doc: UPC -10/06 City &Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http.• / /www.ci.tukwila.wa.us ( P_,„L Permit Number: PG07 -215 Issue Date: 09/10/2007 Permit Expires On: 03/08/2008 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perform of or I authorized to sign and obtain this plumbing /gas piping permit. Date: � - /o - � This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG07 -215 Printed: 09 -10 -2007 Parcel No.: 2623049081 Address: Suite No: Tenant: STARBUCKS 1: ** *PLUMBING AND GAS PIPING * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17100 SOUTHCENTER PY TUKW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. PG07 -215 ISSUED 08/21/2007 09/10/2007 5: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 6: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 7: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 8: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 9: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 10: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: Cond -10/06 * *continued on next page ** PG07 -215 Printed: 09 -10 -2007 Signature: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Print Name: doc: Cond -10/06 PG07 -215 Date: 9 a ordinances governing or local laws regulating Printed: 09 -10 -2007 SITE LOCATION Site Address: 17 /c O Sn u`th ej <h ,, rku ay Tenant Name: �'-� -�A 6 V c'k S Property Owners Name: l.t, a .9 p - .5 e Mailing Address: ; — � CONTACT PERSON -Who do we contact when your permit is ready to be issued Name: Ve. vyt_ �e4P Mailing Address: CITY OF TUKWIL/,, Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us City State Zip E -Mail Address: Fax Number: 264 5 ? 5 6 6efo PLUMBING / GAS PIPING CONTRACTOR INFORMATIO Company Name: Mailing Address: Contact Person: Chuck. o v- E -Mail Address: PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Iii -4-kr o j if Y /b e- - t1 Contractor Registration Number: SA—+t-1k P J H 2 ARCEITECT: "OF RECORD All plans must be ;wet stamped by Company Name: Contact Person: E -Mail Address: DI 14 Plumbing/Gas Permit r Project No. (For office use only) King Co Assessor's Tax No.: Suite Number: /I 0 Floor: New Tenant: .... Yes State Day Telephone: 360 — N4/— / Zl 0 State ..No Zip Ltiakk- 98 z- ° I / Ci State Zip Day Telephone: 360 8VG 4 14 Y l Fax Number: 36 0 eFie 7 ' ys Expiration Date: 1 /-7 - 0 8 Mailing Address: City Day Telephone: Fax Number: Zip ENGINEER OF RECORD - All pl ans must be wet stamped by Engineer of Recor Company Name: AF 1Z Evtia e i Mailing Address: M55 120 'P, A00 kt'v-kiaf A 9 6.33 City Zip Contact Person: )-� 5'a Ck lre -tr" Day Telephone: `4/5" 73? 605'/ E -Mail Address: fI ER I 2.3 Ant_ , COKA. Q:Upplications\Forms- Applications On Line\3 -2006 - Plumbing -Gas Piping Permit Application.doc Revised: 4-2006 bh Fax Number: 1 /757 3? 736 Z Page 1 of 2 Fixture Type: f2h' ". Fixture Type: Qty , Fixtu Type 4ty " "Fixture Type: : Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial I indirect waste Clothes washer, domestic Floor drain / Sinks Dental unit, cuspidor Shower, single head trap Urinals .> Dishwasher, domestic, with independent drain Lavatory , Water Closet Z Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent I, Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Valuation of Project (contractor's bid price): $ 34 QOC ti pp (y►� q p Scope of Work (please provide detailed information): f �u' l�Ltns I w - r6 vcK S re tvtJ e Sha Tr•c luett Di L,.., -511 J Strk{CS RoarSiv■-J5 f f_ k n k � 2 -Ro gesd 1.,.s Building Use (per Int'l Building Code): Re Occupancy (per Int'l Building Code): R 4-- Utility Purveyor: Water: / z.. Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Print Name: C kuCk Lg WAtte Mailing Address: / L/ 3? kg/5 e r Rfi 5-w- Signature: Date Application Accepted: 0•21•o1 Q:\Applications\Fonns- Applications On Line\3 -2006 - Plumbing -Gas Piping Penni Applieation.doc Revised: 4-2006 bh Sewer: �vktAw/T Date: .0 --07 Day Telephone: 30 866 yo y( Oi ! A e5 a_ Ci State Zip Date Application Expires: s s ee Staff Page 2 of 2 f Parcel No.: 2623049081 Address: Suite No: Applicant: STARBUCICS Receipt No.: R07 -01925 Initials: WER User ID: 1655 Payee: TRANSACTION LIST: Type Method Description Payment Cash ACCOUNT ITEM LIST: Description doc: Receiot -06 17100 SOUTUCENTER PY TUKW GEORGE FEARS City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Account Code PLUMBING - NONRES 000/322.100 RECEIPT Amount 20.00 Current Pmts 20.00 Total: $20.00 Permit Number: Status: Applied Date: Issue Date: Payment Amount: $20.00 Payment Date: 09/10/2007 09:42 AM Balance: 30.00 2595 09/10 9710 TOTAL PG07 -215 ISSUED 08/21/2007 09/10/2007 20 },00 Printed: 09 -10 -2007 Parcel No.: 2623049081 Permit Number: PG07 -215 Address: 17100 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 08/21/2007 Applicant: STARBUCKS Issue Date: Receipt No.: R07 -01758 Initials: BLH Payment Date: 08/21/2007 02:19 PM User ID: ADMIN Balance: $0.00 Payee: BATHROOM INC TRANSACTION LIST: Type Method Description Amount Payment Check 16681 320.00 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES PLUMBING - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/345.830 62.00 000/322.100 258.00 Total: $320.00 Payment Amount: $320.00 1870 08/21 9710 TOTAL 320.00 doc: Receiot -06 Printed: 08 -21 -2007 Pro�ec : . ��r �jl�'S Type of I fiction: / / - - c,,? Address: / 7/'G 36/ /l,C�,it/,i ,, / Called: Special Instructions: -3()c- Date Wanted // / / //O Requester: Phone No: ;3 2.43/ INSPECTION RECORD Retain a copy with permit P602-'51 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431- 6 Approved per applicable codes. O Corrections required prior to approval. COMMENTS: fr / 7 / v� t spector: Os No.: SPECTION FEE REQU ED. Prigf to inspection, fee must be 300 Southcenter Blvd.. Su to 100. Call the schedule reinspection. 'Date: Date)/ j r o �� Project: L 5- - -/R62/(15 Type of Inspection: /-ty■D ttl.)( Q Address: /7 /Q 0 S v, /t4e'c , Ri Date Called: _ Special Instructions: Date Wanted: 9 —/ / -0 a.m. Requester: Ph one bi O -- X/ ) - _____JNSPECTION RECORD X6 5- Retain a copy with permit 7 z INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION £ 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 36170 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Date: 58.00 REINSPECTION EE REQUIRED. Pe r to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 10 . Call the schedule reinspection. (Receipt No.: 'Date: ACTIVITY NUMBER: PG07 -215 DATE: 8 -21 -07 PROJECT NAME: STARBUCKS COFFEE SITE ADDRESS: 17100 SOUTHCENTER PY, SUITE 110 X Original Plan Submittal Response to Incomplete Letter #_ Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 1 ing Publ i Works 8 6 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2-28-02 Incomplete ❑ Planning Division ❑ Permit Coordinator E DUE DATE: 08 -23 -07 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU NG: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 09 -20 -07 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 2 Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 8 1 8 7 ) 4 Sink, Clinic flushing Sink, kitchen 3 2 Sink, other (service) 3 1.5 1 3 Sink, wash fountain, circle spray 4 3 i Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Urinal, waterless 0 0 Water closet, tank or valve, 1.6 GPF 6 3 Z I Water closet, tank or valve, >1.6 GPF 8 4 • Non - Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type l ! Q o q l 46' ,' 1,wA Prop Street Address 7 7 ) 4 1 0 1 City _ s ot'lies LLC _S S Owner's Nam Subdivision Name Lot # Subdiv. # / / Block # Building Name N l ST1AQ6C. / S) (if applicable) t.12S 55X11 a Owners Phone N ber (with Area Code) ( Lj Z ) 7 '17 51 Property Contact Phone Number (with Area ode) Owner's Mailing Addre 115 - /113 3eitevue. It)c SC, 75oo‘, ZIP IP A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Total Fxture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units _ 20 aa3 Signature of Owner /Representative Print Name of Owner /Representative 1058 (Rev. 11/05) RCE 1 _ King County Department of Natural Resources and Parks For King County Use Only Account # Monthly Rate 6 Month Rate 6 °t Property Tax ID # •—`1 ( O Party to be Billed (if different from owner) - ° v iM4, Avlenu+' 564.4-11. 9.V3 24)6 3tt /s75 City or Sewer District TL) kt Uv Date of Connection Side Sewer Permit # Demolition of pre- existing building? ❑ Yes r<No Type of building demolished Sewer disconnect date B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility/Process: / — Re.S c ct-rN+ Estimated Wastewater Discharge: Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) _ 187 C. Total Residential Customer Equivalents: (add A & B) A B 73 � 2.3 5,0 7' 3 RCE Gallons /days Date S .5 RCE P6c1jj 5 lECE1VED 4: ;rra� 'r'r IKt.4l)f..a US! 2' 2UO7' i Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. The charge is collected semi- annually. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206 - 684 -1740. I certify that the information given is correct. I understand that t e capacity charge levied will be based on this information and any deviation will require resubmission of corrected da for et �i ination of a revised capacity charge. j White — King County Yellow Local Sewer Agency Pink — Sewer Customer •c:111:) gy License Information License BATHRI *042JA Licensee Name BATHROOM INC, THE Licensee Type CONSTRUCTION CONTRACTOR UBI 601640727 Ind. Ins. Account Id 89315500 Business Type CORPORATION Address 1 1439 KAISER RD SW Address 2 City OLYMPIA County THURSTON State WA Zip 98512 Phone 3608664041 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 4/1/1996 Expiration Date 4/21/2008 Suspend Date Separation Date Parent Company Previous License Next License BEEME * *974JZ Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #5 CBIC SF7743 08/31/2004 Until Cancelled 02/10/2005 $12,000.00 09/07/2004 Business Owner Information Name Role Effective Date Expiration Date LATHROP, ROB PRESIDENT 04 /01/1996 LATHROP, CHUCK VICE PRESIDENT 04 /01/1996 LINCE, MICHAEL VICE PRESIDENT 02/10/2005 Look Up a Contractor, Electri n or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Page 1 of 2 httns:// fortress .wa.eov /lni/bbin /nrinter.asnx ?License= BATHRI *042JA 09/10/2007 • • • * � r dffisic) rev rn m 411 4 -11 v z m 4 r _ .I o � 00 0 =O. • COUNTY, 1 bi,"" No Cc n 27 -7" 34' -10" ■ 13 ll ...."4:6/,''$* M L~ .. M 1 1 .� x'31 •••%1 % O , ` •+ ,' . -A` 1, 1 ' ' t ■ r 10' -11 1/2 i , • • 17 rf F ils cs. a 3 a 0 U t' 1 I • . r 01,7Vej: 4 I , C I I 36' -1" VIF STARBUCKS COFFEE PROJECT: Southcenter & Minkler 17100 Southcenter Parkway, Suite 110 Tukwila, WA 98188 KING COUNTY mob " • 7 1_ 9 " u 2 O > Ea I Nr ®®® 0 541 gu 1g mi g m m 4 A 14 a Flo ag; ' Pgg AIR hi gr C , r ern a o C O 2 4 1 24 8§R 0 PR gV 8 qm: 9 r $ o m r GENERAL PLUMBING NOTES: • NOTE: 'CONTRACTOR' MEANS 'PLUMBING CONTRACTOR' (SEE LANDLORD SCOPE OF WORK ON THIS SHEET TO DETERMINE F WORT( IS BY LANDLORD'S OR STARBUCKS PLUMBING CONTRACTOR) WHEN REFERENCED ANYWHERE IN THE PLUMBING CONSTRUCTION DOCUMENTS UNLESS WORK AND EQUIPMENT HAS BEEN COORDINATED TO BE PROVIDED BY THE GENERAL CONTRACTOR. 'NEEDED', 'PROVIDE', AND 'INSTALL" MEANS ALL ITEMS CALLED OUT IN THE CONTRACT DOCUMENTS AND ANY ADDITIONAL ITEMS NOT CALLED OUT BUT REQUIRED TO MAKE A COMPLETE AND OPERATIONAL SYSTEM. SCOPE THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A COMPLE1E AND FULLY OPERATIONAL PLUMBING SYSTEM. THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL AU. LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE PLUMBING WORK. SITE EXAMINATION THE PLUMBING CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE FIXTURES, EQUIPMENT, AND PIPING WILL BE INSTALLED AND SHALL REPORT ANY CONDITION THAT PREVENTS THE PROPER INSTALLATION OF THE PLUMBING WORK. STANDARDS EQUIPMENT AND MATERIALS SHALL. CONFORM Will APPROPRIATE PROVISIONS OF ASME, ASTM, UL, NEMA, ANSI, ASHRAE, NFPA, IAPMO, OR IMO, OR OTHER APPLICABLE AGENCY AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE 11TH ALL APPLICABLE STATE AND LOCAL ODES AND ORDINANCES AND AHJ. IN CASE OF CONFLICT BETWEEN THE DRAWMNGS CIFICAMIONS AND THE CODES AND ORDINANCES, THE STRICTEST STANDARD SHALL APPLY (IN THE OPINION OF THE ENGINEER). THE PLUMBING CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AND ALL ITEMS IN THE CONTRACT DOCUMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO STARBUCKS. PERMITS AND FEES THE PLUMBING CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES INSPECTIONS, AND OTHER COSTS NECESSARY TO COMPLETE THE PLUMBING WORK. WARRANTY THE PLUMBING CONTRACTOR SMALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXIS11NG WORK DAMAGED IN THE COURSE OF CONSTRUCTION OR REPAIRING DEFECTIVE MATERIALS AND 1113RKMANSIIP. Fad A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. PLUMBING CONTRACTOR RESPONSIBLE FOR 31E INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL PLUMBING EQUIPMENT. DIMENSIONS ARE TO FINISH FACE U.O.N. REFER TO ARCH. SHEETS FOR PLUMBING FITTINGS LOCATED N CASEWORK. COLD WATER SUPPLY LINES INSIDE CASEWORK & BAR AREA TO BE COVERED WITH 1/2' THICK SELF SEALING, SECTIONAL CLOSED —CELL FOAM INSULATION. BUILDING CODE NOTES: FM PER ALL CODES & A.H.J. PIPING: SOIL, WASTE AND VENT PIPING SOIL, WASTE AND VENT PIPING 10' AND SMALLER SHALL BE SERVICE WEIGHT, HUBLESS, CAST RON PIPE AND FITTINGS YWTH NEOPRENE GASKET AND STAINLESS STEEL SHIELD AND CLAMP. PROVIDE HUB —TYPE PPE AND RTIINGS BELOW GRADE WHERE REQUIRED BY LOCAL CODES OR AHJ. SCHEDULE 40 ABS AND FITTINGS WITH SOLVENT WELD MAY BE SUBSTITUTED FOR SOIL, WASTE AND VENT PIPING, ABOVE AND BELOW GROUND IF ALLOWED BY AHJ. HORIZONTAL RUNS SHALL DRAIN AT A GRADE OF 1/4 NCH PER FOOT WHERE POSSIBLE BUT N NO CASE LESS THAN 1/8" PER FOOT. APPLY TO BUILDING DEPARTMENT FOR VARIANCE F 1/8' IS NEEDED. COORDINATE WITH AHJ FOR DRAINAGE REQUIREMENTS FOR EQUIPMENT DESIGNATED WITH INDIRECT WASTE TO FLOOR DRAINS. PROVIDE PIPED DRAIN TO SANITARY F REQUIRED BY AHJ. RELOCATE ANY VENTS NECESSARY TO GIVE 10 FOOT CLEARANCE FROM HVAC INTAKE. COORDINATE WITH HVAC CONTRACTOR. DOMESTIC WATER PIPING DOMESTIC WATER PIPING 2' AND SMALLER SHALL BE COPPER TUBE WITH WROUGHT COPPER SWEAT FITTINGS JOINED 11TH LEAD FREE SOLDER. PROVIDE TYPE " COPPER TUBE ABOVE GROUND AND TYPE 'K' BELOW GROUND. CONDENSATE DRAINAGE PIPING THE PLUMBING CONTRACTOR SHALL PROVIDE CONDENSATE DRAINS FOR AIR HANDUNG UNITS AND STARBUCKS EQUIPMENT. CONDENSATE DRAINAGE PIPING SHALL BE TYPE 'N' COPPER TUBING WITH WROUGHT COPPER SWAT FITTINGS JOINED WITH 50/50 SOLDER. NATURAL GAS PIPING (IF GAS IS USED) GAS PIPING SHALL BE SCHEDULE 40, SEAMLESS, BLACK STEEL PIPE. PROVIDE PIPING SUPPORT BLOCKING ON ROOF, COMPATIBLE WITH ROOFING SYSTEM. COORD. WANT GENERAL AND ROOFING CONTRACTOR BEFORE BID. HANGERS & SUPPORTS THE PLUMBING CONTRACTOR SHALL FURNISH ALL PIPE SUPPORTS NEEDED FOR EQUIPMENT AND MATERIAL ALL HORIZONTAL RUNS OF PIPING SHALL BE SUPPORTED BY PPE HANGERS SPACED NOT MORE THAN 10 FEET O.C. FOR PIPES 1 -1/4' AND LARGER, AND 8 FEET 0.C. FOR PIPES SMALLER THAN 1 -1/4' AND AT EACH JOINT FOR SOIL OR WASTE PIPE ADDITIONAL SUPPORTS SHALL BE PROVIDED WHERE NEEDED TO PREVENT SAGGING. HANGERS AND PIPE ATTACHMENTS TO BE FACTORY FABRICATED WITH GALVANIZED COATINGS; NONMETAUIC COATED FOR HANGERS IN DIRECT CONTACT WITH COPPER TUBING. CONNECTIONS INSTALL UNIONS ADJACENT TO EACH VALVE AND AT FINAL CONNECTION TO EACH PIECE OF EQUFMENT. INSTALL DIELECTRIC COUPLINGS TO CONNECT PIPING MATERIALS OF DISSIMILAR METALS. SCREW JOINT STEEL PIPMLG UP TO AND INCLUDING 1 -1/2'. WELD PIPING USE NON —LEAD, NON — ANTIMONY SOLDER FOR SOLDERING DOMESTIC WATER COPPER PIPE. CLEANOUIS PROVIDE J.R. SMITH OR EQUIVALENT FLOOR AND WALL CLEANOUTS AS INDICATED ON THE DRAWINGS AND WHERE NEEDED IN ALL SOIL, WASTE, AND DRAIN LINES. N AREAS WITH CERAMIC TILE OR CARPETED FLOORING, PROVIDE MAHOUTS WITH SQUARE, ADJUSTABLE, NICKEL BRONZE TOP. IN AREAS WITH RESI.IEiNT FLOORING, PROWL CLEANOUTS WITH SQUARE ADJUSTABLE, NICKEL BRONZE TOP WITH NILE RECESS. CLEANOUTS SHALL BE SAME SIZE AS PIPE EXCEPT THAT CLEANOUTS LARGER THAN 4" "ILL NOT BE REQUIRED. MERE CLEANOUTS OCCUR IN WALLS OF FINISHED AREAS, THEY SHALL BE CONCEALED BEHIND CHROME PLATED ACCESS COVERS. PIPING (CONTINUED): INSTAIIATION INSTALL PIPING FREE OF SAGS AND BENDS. PROVIDE BRACKET STANDOFFS FROM MOUNTING SURFACES SUFFICIENT TO ALLOW 1' CLEANING SPACE AROUND ALL PIPING, INCLUDING ANY ADDED PIPING INSULATION. INSTALL FITTINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS. INSTALL SLEEVES FOR PIPES PASSING THROUGH CONCRETE AND MASONRY WALLS, GYPSUM —BOARD PARTITIONS, CONCRETE FLOOR, AND ROOF SLABS. SEAL PIPE PENETRATIONS THROUGH RATED CONSTRUCTION 1ITH F1RESTOPPING SEALANT MATERIAL UNDERGROUND WATER AND SEWER UNES SHALL BE LAID IN SEPARATE TRENCHES WITH A MINIMUM HORIZONTAL SPACING AS REQUIRED BY CODE AND AHJ, EXCAVATED TO THE PROPER DEPTH AND GRADED TO PRODUCE THE NEEDED FALL. TESTING ALL PIPES SHALL BE TESTED BY AN APPROVED METHOD BEFORE THEY ARE BACKFILLED OR CONCEALED. AFTER ISBN IS COMPLETE, THE PLUMBING CONTRACTOR SHALL DISINFECT THE POTABLE WATER SYSTEM AS REQUIRED BY AHJ. TEST WATER PURITY ACCORDING TO AHJ AND SUBMIT CERTIFIED TEST RESULTS TO AHJ FOR REVIEW AND APPROVAL INSULATION: WATER PIPING PROVIDE THERMAL INSULATION ON AU. HOT & COLD WATER, AND HORIZONTAL WASTE PIPING IN COUNG SPACES, AND ON ALL COLD WATER PIPING IN CASEWORK AND BAR AREAS. USE SELF— SEALING CLOSED CELL FOAM OR JACKE1ED FIBERGLASS INSULATION WITH MANUFACTURER APPROVED ADHESIVES, SEALERS, AND COATINGS. ALL MATERIALS USED SHALL HAVE A FLAME SPREAD INDEX NOT MORE THAN 25 A SMOKE DEVELOPED INDEX NOT MORE THAN 50. UNLESS OTHERYWSE REQUIRED BY THE AHJ OR ENERGY CODES, THE MINIMUM INSULATION LEVELS SHALL BE AS FOLLOWS: PIPE SIZE INSULATION THICKNESS LESS THAN OR 1' EQUAL TO 1J 2' DNA. OR GREATER 1 -1/2' (INSULATION VALUE = k VALUE NOT EXCEEDING 0.27 BTUs INCH/h•tt s F SAFETY INSTALL COVERS NO —SCALD SAFETY COVERS MATH INSULATED FOAM UNER AND TAMPER PROOF STRAP AS FURNISHED BY STARBUCKS AT All EXPOSED PIPING. ICE BIN DRAIN INSULATE ICE BIN COPPER DRAIN ONES YWMH 1/2 ' THICK, SELF— SEALING, SECTIONAL, CLOSED CELL FOAM. RAIN CONDUCTORS OF RAIN CONDUCTORS ARE NEEDED) INSULATE RAIN WATER CONDUCTORS MICH PASS THROUGH OCCUPIED AREAS (AS APPLICABLE) WITH 1/2 ' THICK FIBERGLASS. HVAC PIPING (ON PROJECTS WREN HVAC PIPING IS USED) INSULATE T SUCTION PIPING AND COOLING COIL CONDENSATE PIPING WITH CODE & MANUFACTURER SIZED, SELF SEALING, CLOSED CELL FOAM. INSULATE HVAC HOT AND CHILLED WATER PIPING SYSTEMS AND LOW PRESSURE STEAM AND CONDENSATE PIPING VATH WITH CODE & MANUFACTURER SIZED, HEAVY DUTY, SELF SEALING, JACKETED FIBERGLASS. • VALVES: PLUMBING CONTRACTOR TO PROVIDE VALVES YiHERE INDICATED ON PLANS AND AS NECESSARY FOR PROPER SYSTEM OPERATION AND COMPONENT ISOLATION. INSTALL VALVES FOR EACH FIXTURE AND ITEM OF EQUIPMENT. PROVIDE BRAIDED STAINLESS STEEL HOSE (UNLESS OTHERWISE NOTED) BETWEEN VALVE AND EQUIPMENT IN ACCORDANM YWTH MANUFACTURER'S SPECIFICATIONS. LOCATE SHUT —OFF VALVES ADJACENT TO EQUIPMENT FOR EASY ACCESS SUCH THAT VALVES CAN BE REACHED WITHOUT MOVING EQUIPMENT. PROVIDE STOP VALVES FOR ALL EQUIPMENT WHETHER SHOWN ON THE DRAWINGS OR NOT. VALVES WATER VALVE PRESSURE RATING SHALL BE 125 PSI OR GREATER. UNLESS NOTED OTHERWISE VALVES SHALL BE AS FOLLOWS: VALVE TYPE MANUFACTURER CHECK VALVE (UP TO 21 NIBCO FULL PORT BALL VALVE (UP TO 3) NIKO GATE VALVE (UP TO 3) NIBCO TEMPERATURE AND PRESSURE RELIEF VALVE TWINS WATER HAMMER ARRESTOR WILKINS BACKFLOW PREVENTER WHOLE —HOUSE MINNS BACKFLOW PREVENTER (SINGLE DEVICE) 1MU (INS VACUUM RELIEF VALVE YWLIONS PRESSURE REDUCING VALVE YWL KINS TRAP SEAL PRIMER JAY R. SMITH SUPPLY IF WATER PRESSURE SUPPLIED TO STORE IS GREATER THAN 65 PSI, THEN PROVIDE A PRESSURE REGULATOR TO MAIN SUPPLY TO MAINTAIN WATER PRESSURE (NOT NECESSARILY SHOW ON DRAWWNGS). PROVIDE BACKFLOW PREVENTION AND MAINTAIN SERVICE F REQUIRED BY AHJ. PLUMBING FIXTURES: WATER HEATER PROVIDE A RHEUM /A0. SMITH OR EQUIVALENT, GLASS —LNED, ENERGY EFFICIENT, GAS—FIRED WATER HEATER, WITH CAPACITY AS INDICATED N THE PLANS. WHERE GAS IS NOT AVAILABLE, PROVIDE A RHEUM OR EQUIVALENT ENERGY EFFICIENT, GLASS LINED, ELECTRIC WATER HEATER 11TH SIMILAR CAPACITY AND RECOVERY RATES. PROVIDE INSTALLATION COMPLETE WITH FITTINGS AS SHOW IN THE DRAWINGS. THE WATER TEMPERATURE SHALL BE SET AT 120' F FOR HOT WATER AND 105' F FOR TEMPERED WATER UNLESS REQUIRED OTHERWISE BY A.H.J. WATER FILTRATION — SYSTEM 'A' PLUMBING CONTRACTOR TO INSTALL WATER FL1RA11ON SYSTEM FURNISHED BY STARBUCKS, AS INDICATED ON THE PUNS. PROVIDE INSTALLATION COMPLETE 111H ALL PIPING, FITTINGS, AND EQUIPMENT AS INDICATED ON ME DRAWWNGS 8c AS NEEDED. NOTE CONTRACTOR SHALL CONTACT WATER PROCESSOR (FILTER) SUPPLIER TEN DAYS MINIMUM PRIOR TO NEEDING THE FILTER SYSTEM OPERA1IONAL (CONFIRM LEAD TIME WIM C.M) THE PUIMDNG CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO EQUIPMENT INCLUDING REQUIRED MATERIAL SUCH AS PIPING, VALVES, FILTERS, TRAPS, PECKS VALVES, VACUUM BREAKERS, AND FLEXIBLE AND RIGID TUBING. f \ " REFER TO SCHEDULES ON DRAWINGS (PLUMBING & ARCH. SCHEDULES) FOR A DESCRIPTION OF LISTED ITEMS AND FURNISH ANY AND ALL PLUMBING FIXTURES USTED AS 'GC UNDER THE 'SHIP' COLULMN. ANY DISCREPANCIES ABOUT WHO IS TO PROVIDE PLUMBING FIXTURES IN THE SCHEDULE SHALL BE BROUGHT TO THE ATTENTION OF THE GC PRIOR TO BID. THE GC SHALL COORDINATE YWlf STARBUCKS FOR CLARIFICATION. INSTALL ALL FIXTURES LISTED REGARDLESS OF WHO i SCOPE OF WORK NOTE CONTRACTOR SHALL COORDINATE NTH LANDLORD FOR ANY LANDLORD CONSTRUCTION REQUREMENTS�/SPEECIFICATLONS. IF LANDLOADD DOES HAVE REQUIREMENTS, CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR IBM REQUIREMENTS/SPECIFICATIONS AND ADHERE TO THEM. WHERE LANDLORD REQUIREMENTS ARE MORE STRINGENT THAN SHOW N THESE PLANS, LANDLORD REQUIREMENTS SHALL GOVERN. LANDLORD'S SCOPE OF YIORI(_ THE FOLLOMING ABBREVIATED SCOPE OF YMORK SHALL BE COMPLETED BY THE LANDLORD'S CONTRACTORS AS SPECIFIED RI THE 'LANDLORD WORKLET TER — EMIT C -1 AND C-2'. NOT ALL THE LANDLORD'S WORK IS NECESSARILY CALLED FOR IN THIS DESCRIPTION OR RI THESE PLANS. REFERENCE THE 'LANDLORD 1AORRQETIER FOR A COMPLETE DESCRPTKOt OF WORK SCOPE. TIE LAIND t SIHM 1. FURNISH AND INSTALL (FM) GAS SERVICE 1111H GAS PIPING SZED` ROWED AND CONNECTED TO HVAC UNITS. FM STUBS FOR HOT WATER TANK AND FIREPLACE. 2. FIN SHARED 1 -1/2' DOMESTIC WATER SERVICE TO STARBUCKS SPACE MIME LINE SIZE ADD LOCATION AS INDICATED N THESE PLANS. F&1 1 -1/2' WATER SEMI LNE TO 11'ATER S<BMETER LOCATED PER THESE PLANS (WATER WINDER MAY BE LOCATED OUTSIDE STARBUQC'S SPACE AT LANDLORD'S 3. FUI A 4' (OR GREATER F REQUIRED BY AFU) SANITARY SEAR WASTE UNE 10 STARBUOCS SPACE AS SOW ON THESE PLANS. INVERT ELEVATION OF WASTE LIE SHALL ALLOW WASTE/MIT DESIGN SHOWN N THESE PLANS AT i/8" PER FOOT SLOPE CONTACT AER ENGINEERS F INVERT CANNOT BE NET AT 1/8' BEFORE O 4. FOi VEINS) JWU ROOF NIH CAPAOTY TO SERVE FIXTURES, MOOED ABOVE MING N STA 1 ICKS SPACE. AND AS SHOWN IN THESE PLANS. 5. FAIN RECESSED FREEZE PROOF HOSE 003 NTH 3/4' WATER LIRE ROUTED TO AN ACCES9OLE LOCATION FOR CONNECTION BY TENANT (COORDINAW NTH sTARRJI S FOR LOCATION). 6. FM OQDENSAIE PIPING FROM HVAC UNITS. 7_ Fad FIRE SPRINMER SYSTEM I REQUIRED BY AHJ OR LANDLORD oat NOT SHOW N THESE RAINS): SPRINKLER SYSTEM (NCIUOING DROPS MO HEADS) SHALL BE FULLY FUICUONAL NO INSPECTED /APPROVED BY THE MU. FM 24-18 PER DAY IIONITORINZ SYSTEM F REWIRED BY NU. FM MIL INTERIM ADD N B MI NO IS SEPA METERED R� `0 MOT SHORN N PLIWS PRE4EKTiq�1 caw • i PLUMBING SYMBOLS LEGEND • —RO G I�I Q —0 t- 0 Fad oilo%. , S OR W SANITARY OR WASIK PIPING BELOW SLAB (U.O.N.) V SANITARY VENT PIPING GW GREASE WASTE PIPING BELOW SLAB (U.0.N.) CD CONDENSATE DRAIN CW COLD WATER PIPING HW HOT WATER PIPING CWF COLD WATER FILTERED CWN COLD WATER NANO FILTERED CWS COLD WATER SOFTENED 1W TEMPERED HOT WATER RO REVERSE OSMOSIS WATER G GAS PIPING BV BALL VALVE GV GATE VALVE CH. V CHECK VALVE PRV PRESSURE REDUCING VALVE RV RELIEF VALVE BFP BACKFLOW PREVENTER HB HOSE BI88 SHOCK ABSORBER STRAINER KO WALL CLEANOUT FLOOR CLEANOUT FS FLOOR SINK WMM WATER METER CONNECT TO DOSING STOP VALVE AT FIXTURE U.O.N. UNLESS OTHERWISE NOTED U.N.O. UNLESS NOTED OTHERWISE FURNISH & INSTALL AUTHORITIES HAVING FCO LL JURISDICTION LANDLORD 9. FM 4' GREASE WASTE LINE TO SPACE FROM AN APPROVED SIZED EXTERIOR GREASE INTERCEPTOR. STARBUCKS CONTRACTORS SCOPE OF KIRK; STARBUCKS CONTRACTORS SHALL BE RUPONSBL.E FOR ALL WORK NOT COVERED ABOVE TO COMPLETE AND MAKE FULLY OPERATIONAL ALL PLUMBING AND SPRINKLER SYSTEMS. COORDINATE MIRTH STARBUCKS GC. FEcatED i'c r = i ?{'1 • O a R P� c STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 nESE PINS MD SPOc neuron, AS S L. AS SUBMCIer NNE AID woo. 1RAOOWecS Mb 0E506 ME ME OR UME PROPERW OF SUROUP3 OORAORMON. Mfr REPROCU EON. I CmcAnoM, oI5 IESSURE MOM USE OF RIESE M MEAN .S (OR ANY PORTION OF nEE10 ■OIIOUJ SWI6uW PRIOR MORN CONSENT 6 wacky PROIIIEQ. AER ENGINEERS 11155 120TH AVE. N.E. (425) 739 -6051 SUITE 200 (425) 739 -7362 KIRKLAND, WA 98033 AERI230AOLCON REV DATE JC DESCRIPTION h STORE #: 14274 PROJECT #: 42071 -001 CONCEPT: MSS ISSUE DATE 077 CHECKED: JOHN BEEBE DESIGNED: CHRIS RENSCH DRAWN: SHARON HARRIS SHEET TITLE PLUMBING SPECIFICATIONS SCALE: (00 NOT SCALE DRAWINGS) SHEET NURSER P1.0 GENERAL PLUMBING NOTES: • NOTE: 'CONTRACTOR' MEANS 'PLUMBING CONTRACTOR' (SEE LANDLORD SCOPE OF WORK ON THIS SHEET TO DETERMINE F WORT( IS BY LANDLORD'S OR STARBUCKS PLUMBING CONTRACTOR) WHEN REFERENCED ANYWHERE IN THE PLUMBING CONSTRUCTION DOCUMENTS UNLESS WORK AND EQUIPMENT HAS BEEN COORDINATED TO BE PROVIDED BY THE GENERAL CONTRACTOR. 'NEEDED', 'PROVIDE', AND 'INSTALL" MEANS ALL ITEMS CALLED OUT IN THE CONTRACT DOCUMENTS AND ANY ADDITIONAL ITEMS NOT CALLED OUT BUT REQUIRED TO MAKE A COMPLETE AND OPERATIONAL SYSTEM. SCOPE THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A COMPLE1E AND FULLY OPERATIONAL PLUMBING SYSTEM. THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL AU. LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE PLUMBING WORK. SITE EXAMINATION THE PLUMBING CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE FIXTURES, EQUIPMENT, AND PIPING WILL BE INSTALLED AND SHALL REPORT ANY CONDITION THAT PREVENTS THE PROPER INSTALLATION OF THE PLUMBING WORK. STANDARDS EQUIPMENT AND MATERIALS SHALL. CONFORM Will APPROPRIATE PROVISIONS OF ASME, ASTM, UL, NEMA, ANSI, ASHRAE, NFPA, IAPMO, OR IMO, OR OTHER APPLICABLE AGENCY AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE 11TH ALL APPLICABLE STATE AND LOCAL ODES AND ORDINANCES AND AHJ. IN CASE OF CONFLICT BETWEEN THE DRAWMNGS CIFICAMIONS AND THE CODES AND ORDINANCES, THE STRICTEST STANDARD SHALL APPLY (IN THE OPINION OF THE ENGINEER). THE PLUMBING CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AND ALL ITEMS IN THE CONTRACT DOCUMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO STARBUCKS. PERMITS AND FEES THE PLUMBING CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES INSPECTIONS, AND OTHER COSTS NECESSARY TO COMPLETE THE PLUMBING WORK. WARRANTY THE PLUMBING CONTRACTOR SMALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXIS11NG WORK DAMAGED IN THE COURSE OF CONSTRUCTION OR REPAIRING DEFECTIVE MATERIALS AND 1113RKMANSIIP. Fad A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. PLUMBING CONTRACTOR RESPONSIBLE FOR 31E INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL PLUMBING EQUIPMENT. DIMENSIONS ARE TO FINISH FACE U.O.N. REFER TO ARCH. SHEETS FOR PLUMBING FITTINGS LOCATED N CASEWORK. COLD WATER SUPPLY LINES INSIDE CASEWORK & BAR AREA TO BE COVERED WITH 1/2' THICK SELF SEALING, SECTIONAL CLOSED —CELL FOAM INSULATION. BUILDING CODE NOTES: FM PER ALL CODES & A.H.J. PIPING: SOIL, WASTE AND VENT PIPING SOIL, WASTE AND VENT PIPING 10' AND SMALLER SHALL BE SERVICE WEIGHT, HUBLESS, CAST RON PIPE AND FITTINGS YWTH NEOPRENE GASKET AND STAINLESS STEEL SHIELD AND CLAMP. PROVIDE HUB —TYPE PPE AND RTIINGS BELOW GRADE WHERE REQUIRED BY LOCAL CODES OR AHJ. SCHEDULE 40 ABS AND FITTINGS WITH SOLVENT WELD MAY BE SUBSTITUTED FOR SOIL, WASTE AND VENT PIPING, ABOVE AND BELOW GROUND IF ALLOWED BY AHJ. HORIZONTAL RUNS SHALL DRAIN AT A GRADE OF 1/4 NCH PER FOOT WHERE POSSIBLE BUT N NO CASE LESS THAN 1/8" PER FOOT. APPLY TO BUILDING DEPARTMENT FOR VARIANCE F 1/8' IS NEEDED. COORDINATE WITH AHJ FOR DRAINAGE REQUIREMENTS FOR EQUIPMENT DESIGNATED WITH INDIRECT WASTE TO FLOOR DRAINS. PROVIDE PIPED DRAIN TO SANITARY F REQUIRED BY AHJ. RELOCATE ANY VENTS NECESSARY TO GIVE 10 FOOT CLEARANCE FROM HVAC INTAKE. COORDINATE WITH HVAC CONTRACTOR. DOMESTIC WATER PIPING DOMESTIC WATER PIPING 2' AND SMALLER SHALL BE COPPER TUBE WITH WROUGHT COPPER SWEAT FITTINGS JOINED 11TH LEAD FREE SOLDER. PROVIDE TYPE " COPPER TUBE ABOVE GROUND AND TYPE 'K' BELOW GROUND. CONDENSATE DRAINAGE PIPING THE PLUMBING CONTRACTOR SHALL PROVIDE CONDENSATE DRAINS FOR AIR HANDUNG UNITS AND STARBUCKS EQUIPMENT. CONDENSATE DRAINAGE PIPING SHALL BE TYPE 'N' COPPER TUBING WITH WROUGHT COPPER SWAT FITTINGS JOINED WITH 50/50 SOLDER. NATURAL GAS PIPING (IF GAS IS USED) GAS PIPING SHALL BE SCHEDULE 40, SEAMLESS, BLACK STEEL PIPE. PROVIDE PIPING SUPPORT BLOCKING ON ROOF, COMPATIBLE WITH ROOFING SYSTEM. COORD. WANT GENERAL AND ROOFING CONTRACTOR BEFORE BID. HANGERS & SUPPORTS THE PLUMBING CONTRACTOR SHALL FURNISH ALL PIPE SUPPORTS NEEDED FOR EQUIPMENT AND MATERIAL ALL HORIZONTAL RUNS OF PIPING SHALL BE SUPPORTED BY PPE HANGERS SPACED NOT MORE THAN 10 FEET O.C. FOR PIPES 1 -1/4' AND LARGER, AND 8 FEET 0.C. FOR PIPES SMALLER THAN 1 -1/4' AND AT EACH JOINT FOR SOIL OR WASTE PIPE ADDITIONAL SUPPORTS SHALL BE PROVIDED WHERE NEEDED TO PREVENT SAGGING. HANGERS AND PIPE ATTACHMENTS TO BE FACTORY FABRICATED WITH GALVANIZED COATINGS; NONMETAUIC COATED FOR HANGERS IN DIRECT CONTACT WITH COPPER TUBING. CONNECTIONS INSTALL UNIONS ADJACENT TO EACH VALVE AND AT FINAL CONNECTION TO EACH PIECE OF EQUFMENT. INSTALL DIELECTRIC COUPLINGS TO CONNECT PIPING MATERIALS OF DISSIMILAR METALS. SCREW JOINT STEEL PIPMLG UP TO AND INCLUDING 1 -1/2'. WELD PIPING USE NON —LEAD, NON — ANTIMONY SOLDER FOR SOLDERING DOMESTIC WATER COPPER PIPE. CLEANOUIS PROVIDE J.R. SMITH OR EQUIVALENT FLOOR AND WALL CLEANOUTS AS INDICATED ON THE DRAWINGS AND WHERE NEEDED IN ALL SOIL, WASTE, AND DRAIN LINES. N AREAS WITH CERAMIC TILE OR CARPETED FLOORING, PROVIDE MAHOUTS WITH SQUARE, ADJUSTABLE, NICKEL BRONZE TOP. IN AREAS WITH RESI.IEiNT FLOORING, PROWL CLEANOUTS WITH SQUARE ADJUSTABLE, NICKEL BRONZE TOP WITH NILE RECESS. CLEANOUTS SHALL BE SAME SIZE AS PIPE EXCEPT THAT CLEANOUTS LARGER THAN 4" "ILL NOT BE REQUIRED. MERE CLEANOUTS OCCUR IN WALLS OF FINISHED AREAS, THEY SHALL BE CONCEALED BEHIND CHROME PLATED ACCESS COVERS. PIPING (CONTINUED): INSTAIIATION INSTALL PIPING FREE OF SAGS AND BENDS. PROVIDE BRACKET STANDOFFS FROM MOUNTING SURFACES SUFFICIENT TO ALLOW 1' CLEANING SPACE AROUND ALL PIPING, INCLUDING ANY ADDED PIPING INSULATION. INSTALL FITTINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS. INSTALL SLEEVES FOR PIPES PASSING THROUGH CONCRETE AND MASONRY WALLS, GYPSUM —BOARD PARTITIONS, CONCRETE FLOOR, AND ROOF SLABS. SEAL PIPE PENETRATIONS THROUGH RATED CONSTRUCTION 1ITH F1RESTOPPING SEALANT MATERIAL UNDERGROUND WATER AND SEWER UNES SHALL BE LAID IN SEPARATE TRENCHES WITH A MINIMUM HORIZONTAL SPACING AS REQUIRED BY CODE AND AHJ, EXCAVATED TO THE PROPER DEPTH AND GRADED TO PRODUCE THE NEEDED FALL. TESTING ALL PIPES SHALL BE TESTED BY AN APPROVED METHOD BEFORE THEY ARE BACKFILLED OR CONCEALED. AFTER ISBN IS COMPLETE, THE PLUMBING CONTRACTOR SHALL DISINFECT THE POTABLE WATER SYSTEM AS REQUIRED BY AHJ. TEST WATER PURITY ACCORDING TO AHJ AND SUBMIT CERTIFIED TEST RESULTS TO AHJ FOR REVIEW AND APPROVAL INSULATION: WATER PIPING PROVIDE THERMAL INSULATION ON AU. HOT & COLD WATER, AND HORIZONTAL WASTE PIPING IN COUNG SPACES, AND ON ALL COLD WATER PIPING IN CASEWORK AND BAR AREAS. USE SELF— SEALING CLOSED CELL FOAM OR JACKE1ED FIBERGLASS INSULATION WITH MANUFACTURER APPROVED ADHESIVES, SEALERS, AND COATINGS. ALL MATERIALS USED SHALL HAVE A FLAME SPREAD INDEX NOT MORE THAN 25 A SMOKE DEVELOPED INDEX NOT MORE THAN 50. UNLESS OTHERYWSE REQUIRED BY THE AHJ OR ENERGY CODES, THE MINIMUM INSULATION LEVELS SHALL BE AS FOLLOWS: PIPE SIZE INSULATION THICKNESS LESS THAN OR 1' EQUAL TO 1J 2' DNA. OR GREATER 1 -1/2' (INSULATION VALUE = k VALUE NOT EXCEEDING 0.27 BTUs INCH/h•tt s F SAFETY INSTALL COVERS NO —SCALD SAFETY COVERS MATH INSULATED FOAM UNER AND TAMPER PROOF STRAP AS FURNISHED BY STARBUCKS AT All EXPOSED PIPING. ICE BIN DRAIN INSULATE ICE BIN COPPER DRAIN ONES YWMH 1/2 ' THICK, SELF— SEALING, SECTIONAL, CLOSED CELL FOAM. RAIN CONDUCTORS OF RAIN CONDUCTORS ARE NEEDED) INSULATE RAIN WATER CONDUCTORS MICH PASS THROUGH OCCUPIED AREAS (AS APPLICABLE) WITH 1/2 ' THICK FIBERGLASS. HVAC PIPING (ON PROJECTS WREN HVAC PIPING IS USED) INSULATE T SUCTION PIPING AND COOLING COIL CONDENSATE PIPING WITH CODE & MANUFACTURER SIZED, SELF SEALING, CLOSED CELL FOAM. INSULATE HVAC HOT AND CHILLED WATER PIPING SYSTEMS AND LOW PRESSURE STEAM AND CONDENSATE PIPING VATH WITH CODE & MANUFACTURER SIZED, HEAVY DUTY, SELF SEALING, JACKETED FIBERGLASS. • VALVES: PLUMBING CONTRACTOR TO PROVIDE VALVES YiHERE INDICATED ON PLANS AND AS NECESSARY FOR PROPER SYSTEM OPERATION AND COMPONENT ISOLATION. INSTALL VALVES FOR EACH FIXTURE AND ITEM OF EQUIPMENT. PROVIDE BRAIDED STAINLESS STEEL HOSE (UNLESS OTHERWISE NOTED) BETWEEN VALVE AND EQUIPMENT IN ACCORDANM YWTH MANUFACTURER'S SPECIFICATIONS. LOCATE SHUT —OFF VALVES ADJACENT TO EQUIPMENT FOR EASY ACCESS SUCH THAT VALVES CAN BE REACHED WITHOUT MOVING EQUIPMENT. PROVIDE STOP VALVES FOR ALL EQUIPMENT WHETHER SHOWN ON THE DRAWINGS OR NOT. VALVES WATER VALVE PRESSURE RATING SHALL BE 125 PSI OR GREATER. UNLESS NOTED OTHERWISE VALVES SHALL BE AS FOLLOWS: VALVE TYPE MANUFACTURER CHECK VALVE (UP TO 21 NIBCO FULL PORT BALL VALVE (UP TO 3) NIKO GATE VALVE (UP TO 3) NIBCO TEMPERATURE AND PRESSURE RELIEF VALVE TWINS WATER HAMMER ARRESTOR WILKINS BACKFLOW PREVENTER WHOLE —HOUSE MINNS BACKFLOW PREVENTER (SINGLE DEVICE) 1MU (INS VACUUM RELIEF VALVE YWLIONS PRESSURE REDUCING VALVE YWL KINS TRAP SEAL PRIMER JAY R. SMITH SUPPLY IF WATER PRESSURE SUPPLIED TO STORE IS GREATER THAN 65 PSI, THEN PROVIDE A PRESSURE REGULATOR TO MAIN SUPPLY TO MAINTAIN WATER PRESSURE (NOT NECESSARILY SHOW ON DRAWWNGS). PROVIDE BACKFLOW PREVENTION AND MAINTAIN SERVICE F REQUIRED BY AHJ. PLUMBING FIXTURES: WATER HEATER PROVIDE A RHEUM /A0. SMITH OR EQUIVALENT, GLASS —LNED, ENERGY EFFICIENT, GAS—FIRED WATER HEATER, WITH CAPACITY AS INDICATED N THE PLANS. WHERE GAS IS NOT AVAILABLE, PROVIDE A RHEUM OR EQUIVALENT ENERGY EFFICIENT, GLASS LINED, ELECTRIC WATER HEATER 11TH SIMILAR CAPACITY AND RECOVERY RATES. PROVIDE INSTALLATION COMPLETE WITH FITTINGS AS SHOW IN THE DRAWINGS. THE WATER TEMPERATURE SHALL BE SET AT 120' F FOR HOT WATER AND 105' F FOR TEMPERED WATER UNLESS REQUIRED OTHERWISE BY A.H.J. WATER FILTRATION — SYSTEM 'A' PLUMBING CONTRACTOR TO INSTALL WATER FL1RA11ON SYSTEM FURNISHED BY STARBUCKS, AS INDICATED ON THE PUNS. PROVIDE INSTALLATION COMPLETE 111H ALL PIPING, FITTINGS, AND EQUIPMENT AS INDICATED ON ME DRAWWNGS 8c AS NEEDED. NOTE CONTRACTOR SHALL CONTACT WATER PROCESSOR (FILTER) SUPPLIER TEN DAYS MINIMUM PRIOR TO NEEDING THE FILTER SYSTEM OPERA1IONAL (CONFIRM LEAD TIME WIM C.M) THE PUIMDNG CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO EQUIPMENT INCLUDING REQUIRED MATERIAL SUCH AS PIPING, VALVES, FILTERS, TRAPS, PECKS VALVES, VACUUM BREAKERS, AND FLEXIBLE AND RIGID TUBING. f \ " REFER TO SCHEDULES ON DRAWINGS (PLUMBING & ARCH. SCHEDULES) FOR A DESCRIPTION OF LISTED ITEMS AND FURNISH ANY AND ALL PLUMBING FIXTURES USTED AS 'GC UNDER THE 'SHIP' COLULMN. ANY DISCREPANCIES ABOUT WHO IS TO PROVIDE PLUMBING FIXTURES IN THE SCHEDULE SHALL BE BROUGHT TO THE ATTENTION OF THE GC PRIOR TO BID. THE GC SHALL COORDINATE YWlf STARBUCKS FOR CLARIFICATION. INSTALL ALL FIXTURES LISTED REGARDLESS OF WHO i SCOPE OF WORK NOTE CONTRACTOR SHALL COORDINATE NTH LANDLORD FOR ANY LANDLORD CONSTRUCTION REQUREMENTS�/SPEECIFICATLONS. IF LANDLOADD DOES HAVE REQUIREMENTS, CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR IBM REQUIREMENTS/SPECIFICATIONS AND ADHERE TO THEM. WHERE LANDLORD REQUIREMENTS ARE MORE STRINGENT THAN SHOW N THESE PLANS, LANDLORD REQUIREMENTS SHALL GOVERN. LANDLORD'S SCOPE OF YIORI(_ THE FOLLOMING ABBREVIATED SCOPE OF YMORK SHALL BE COMPLETED BY THE LANDLORD'S CONTRACTORS AS SPECIFIED RI THE 'LANDLORD WORKLET TER — EMIT C -1 AND C-2'. NOT ALL THE LANDLORD'S WORK IS NECESSARILY CALLED FOR IN THIS DESCRIPTION OR RI THESE PLANS. REFERENCE THE 'LANDLORD 1AORRQETIER FOR A COMPLETE DESCRPTKOt OF WORK SCOPE. TIE LAIND t SIHM 1. FURNISH AND INSTALL (FM) GAS SERVICE 1111H GAS PIPING SZED` ROWED AND CONNECTED TO HVAC UNITS. FM STUBS FOR HOT WATER TANK AND FIREPLACE. 2. FIN SHARED 1 -1/2' DOMESTIC WATER SERVICE TO STARBUCKS SPACE MIME LINE SIZE ADD LOCATION AS INDICATED N THESE PLANS. F&1 1 -1/2' WATER SEMI LNE TO 11'ATER S<BMETER LOCATED PER THESE PLANS (WATER WINDER MAY BE LOCATED OUTSIDE STARBUQC'S SPACE AT LANDLORD'S 3. FUI A 4' (OR GREATER F REQUIRED BY AFU) SANITARY SEAR WASTE UNE 10 STARBUOCS SPACE AS SOW ON THESE PLANS. INVERT ELEVATION OF WASTE LIE SHALL ALLOW WASTE/MIT DESIGN SHOWN N THESE PLANS AT i/8" PER FOOT SLOPE CONTACT AER ENGINEERS F INVERT CANNOT BE NET AT 1/8' BEFORE O 4. FOi VEINS) JWU ROOF NIH CAPAOTY TO SERVE FIXTURES, MOOED ABOVE MING N STA 1 ICKS SPACE. AND AS SHOWN IN THESE PLANS. 5. FAIN RECESSED FREEZE PROOF HOSE 003 NTH 3/4' WATER LIRE ROUTED TO AN ACCES9OLE LOCATION FOR CONNECTION BY TENANT (COORDINAW NTH sTARRJI S FOR LOCATION). 6. FM OQDENSAIE PIPING FROM HVAC UNITS. 7_ Fad FIRE SPRINMER SYSTEM I REQUIRED BY AHJ OR LANDLORD oat NOT SHOW N THESE RAINS): SPRINKLER SYSTEM (NCIUOING DROPS MO HEADS) SHALL BE FULLY FUICUONAL NO INSPECTED /APPROVED BY THE MU. FM 24-18 PER DAY IIONITORINZ SYSTEM F REWIRED BY NU. FM MIL INTERIM ADD N B MI NO IS SEPA METERED R� `0 MOT SHORN N PLIWS PRE4EKTiq�1 caw • i PLUMBING SYMBOLS LEGEND • —RO G I�I Q —0 t- 0 Fad oilo%. , S OR W SANITARY OR WASIK PIPING BELOW SLAB (U.O.N.) V SANITARY VENT PIPING GW GREASE WASTE PIPING BELOW SLAB (U.0.N.) CD CONDENSATE DRAIN CW COLD WATER PIPING HW HOT WATER PIPING CWF COLD WATER FILTERED CWN COLD WATER NANO FILTERED CWS COLD WATER SOFTENED 1W TEMPERED HOT WATER RO REVERSE OSMOSIS WATER G GAS PIPING BV BALL VALVE GV GATE VALVE CH. V CHECK VALVE PRV PRESSURE REDUCING VALVE RV RELIEF VALVE BFP BACKFLOW PREVENTER HB HOSE BI88 SHOCK ABSORBER STRAINER KO WALL CLEANOUT FLOOR CLEANOUT FS FLOOR SINK WMM WATER METER CONNECT TO DOSING STOP VALVE AT FIXTURE U.O.N. UNLESS OTHERWISE NOTED U.N.O. UNLESS NOTED OTHERWISE FURNISH & INSTALL AUTHORITIES HAVING FCO LL JURISDICTION LANDLORD 9. FM 4' GREASE WASTE LINE TO SPACE FROM AN APPROVED SIZED EXTERIOR GREASE INTERCEPTOR. STARBUCKS CONTRACTORS SCOPE OF KIRK; STARBUCKS CONTRACTORS SHALL BE RUPONSBL.E FOR ALL WORK NOT COVERED ABOVE TO COMPLETE AND MAKE FULLY OPERATIONAL ALL PLUMBING AND SPRINKLER SYSTEMS. COORDINATE MIRTH STARBUCKS GC. FEcatED i'c r = i ?{'1 • O a 1 P012 1 ICE BIN 95LBS - STAINLESS SPOKANE STAINLESS ZURN Z7440 -WF 1 /2" CW /TW 1 I 15 "X25 "X20" 194924 VD P017 2 SINK - STD RESTROOM FOR KOHLER K2005 -ZZ 1 /2" CW/HW 10 1/4" W/ SOAP DISP. HOLE 139086 3PL P018 1 SINK DROP -1N FOR MSS CBS SPOKANE STAINLESS ZURN 2- 1996 -SF 1 /2" CW /HW 1 1 /2" D W/ DRAINBOARD & GRATE 194925 VD P021 1 SINK - SS HAND ® WORKROOM SPOKANE STAINLESS EHS -14 -W 1/2" IPS H/C 1 1/2" D WALL MTD W /FAUCET - ADA COMPLIANT 179715 3PL P026 1 SINK - WORKROOM 3 COMPART SPOKANE STAINLESS 3C16X20 -2 -18 2" 0 16 X 20 X 16 120019 3PL P034 3 SINK FLOOR - 12" SQ FERGUSON ENTERPRISES ZURN FD2375 -NH3 1 /2" CW " 3 0 W /3" PLUMBING TAIL PIECE 180465 3PL P036 1 MOP SINK FERGUSON ENTERPRISES ZURN Z- 1996 -24 1/2" CWF 3" 0 180461 3PL PO45 . 2 TOILET -- LEFT HAND KOHLER K- 3544 -RA 3/8" NPS 3 1/2" 0 12" ROUGH -IN 189613 GC P390 1 10" DIPPERWELL DEEP DRAWN FERGUSON ENTERPRISES ZURN Z -826S1 1 2" CW / 1 1/2" INDIRECT 357151 3PL P392 1 45 LB ICE BIN 1" INDIRECT 344430 3PL P393 2 WORKSINK 1/2" HW 1/2" CW 1 1 /2" INDIRECT 344429 3PL P395 1 HAND SINK STAINLESS STEEL 1/2" TW 1 /2" CW 1 1/2" DIRECT 344428 3PL P354 3 , FAUCET HANDSINK ZURN FERGUSON ENTERPRISES ZURN Z7440 -WF 1 /2" CW /TW AT RESTROOM HAND SINK 190076 3PL P355 1 WORKSINK FAUCET PRE -RINSE COMPONENT HARDWARE GROUP KN53- 1000 -BR 1 /2" CW/HW AT WORKROOM COMPARTMENT SINKS 181032 3PL P356 1 FAUCET & BRACKET FOR MOP FERGUSON ENTERPRISES ZURN 2- 1996 -SF 1 /2" CW /HW INDIRECT INCLS INTGRL VACUUM BRKER & STP CHK VLVS 277679 3PL P358 1 OUTDOOR SPIGOT ' (BY LANDLORD) FERGUSON ENTERPRISES ZURN 21320 -C -6 3/8" INLET LL P360 1 FAUCET 14" WORKROOM ADD -ON COMPONENT HARDWARE GROUP KN55 -7014 183203 3PL P367 1 FAUCET BACKBAR PITCHER RINSER FERGUSON ENTERPRISES ZURN Z -825F1 1 /2" CW GC INSTALL BACKFLOW PREVENTER IN SUPPLY 182121 3PL P376 1 FAUCET 12" GLASS FILLER COMPONENT HARDWARE KN26 -5012 SP 1/2" CWF 185897 3PL P377 1 FAUCET LABORATORY HOT & COLD i FERGUSON ENTERPRISES INC ZURN Z -826F1 1/2" CW/HW GC INSTALL BACKFLOW PREVENTER IN SUPPLY 189613 3PL P380 2 FAUCET BACKBAR WORKSINK FERGUSON ENTERPRISES ZURN Z -826S1 1/2" CW/HW 194916 3PL P803 2 PIPE PROTECTOR SKAL & GARD SG -200B PTRAP AND RISER PROTECTOR GC P804 3 FLOOR SINK HALF WIRE GRATE FERGUSON ENTERPRISES ZURN 180466 3PL P806 1 GAS WATER HEATER A.O. SMITH GCV -50 • 3/4" CW /HW INDIRECT 40MBH INPUT / 50GAL CAP. 40_2 RECOVERY 0 90' GC O 0 % • et to (CONFIRM AU. QUANTITIES KITH PLAN VIEW AND STARBUCKS) ITEM# QTY DESCRIPTION MANUFACTURER MODEL I VOLTS AMPS SUPPLY WASTE REMARKS SKU O SHIP FIXTURES SEATING OUTDOOR SEATING HVAC UNIT ON ROOF (GAS FM BY LANDLORD) 3 /4 "CWF SEAT INN G 4"G —HOLD TIGHT TO-' STRUCUJRE SALES PLUMBING SUPPLY PLAN 1 1/211W\ l i . � t ICE MACHINE REMO CONDENSER ON ROOF 0 1 2 3 4 8 12 rtr1.1'1.1 PLUMBING SCHEDULES TO GAS METER MANIFOLD ON NORTH SIDE OF BUILDING (M) I WORKROOM (CONFIRM ALL QUANTITIES KITH PLAN NEW AND STARBUCKS) ITEM# QTY DESCRIPTION MANUFACTURER MODEL S VOLTS AMPS SUPPLY WASTE REMARKS SKU # SHIP FAUCETS ACCESSORIES 1 -1/2 G —BASED ON LOW PRESSURE OVER A TOTAL DISTANCE OF 230 FEET (� I= DISTANCE IS FURTHER. SIZE PER CODE WOMEN'S RESTROOM HVAC UNIT ROOF (GAS FM LANDLORD) h 1:: .___ I '` L J : � i M RR � � I � ## —EN'S ✓ 1 VEST. 1 l 3 /4'CW . M t IRESTROO ` I _I - f 1 . I` -1 ' ! J ! i I - ear ® 1/2' DISCHARGE LINE & 3/8" LIQUID INSULATED PRECHARGED REFRIGERANT LINES FROM VICE MACHINE TO REMOTE CONDENSER. COORDINATE KITH GC FOR EXACT LOCATION AND SUPPORT OF CONDENSER SEE DETAIL FOR ROOF PENETRATION. CONNECT TO LANDLORD PROVIDED GAS SERVICE (CONFIRM). RUN ALL PIPING CONCEALED (1W). 3/4" GAS TO FIREPLACE WITH APPROVED AND ACCESSIBLE SHUT —OFF VALVE. CONFIRM PROPOSED ROUTE OF GAS UNE TO FIREPLACE WI1H STARBUCKS & INSPECTOR PRIOR TO BID. 0 0 0 PLUMBING GENEARL NOTES ® F&I A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. O PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. UC COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL PLUMBING EQUIPMENT. DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED. REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK. COLD WATER SUPPLY LINES INSIDE CASEWORK & BAR AREA TO BE COVERED 1M1H 1/2' TRACK SELF SEALING. SECTIONAL CLOSED —CELL FOAM INSULATION. REFER TO SPECIFICATIONS FOR HOT WATER SUPPLY UNE INSULATION REQUIREMENTS. CI CONTRACTOR SHALL CONTACT WATER FILTER SUPPLIER 10 DAYS (MINIMUM) BEFORE THE TIME THAT THE FILTER SYSTEM IS TO BE STARTED I* . OH STOP VALVES SHALL BE Fad AT ALL PLUMBING FUTURES EVEN IF NOT SHOYYN IN PLAN. O RUN ALL PIPING CONCEALED. GAS REQUIREMENTS: SYSTEM IS SIZED FOR LOW PRESSURE GAS, RTU -1 = 120,000 81111 RTU -2 = 120,000 BTUH HOT WATER TANK = 40,000 BTUH TOTAL = 280,000 BIM SEE PUAIBING WASTE/104T PLAN & U NDERSLAB CONDUIT PLAN FOR ADDITIONAL UNOERSLAB ITEMS. PLUMBING PLAN KEY NOTES t � �rlri / s 1 ' ,j- O 1' CW TO WATER HEATER & 1" HW FROM WATER HEATER. INSTALL 3/4" TEMPERTATURE MIXING VALVE ABOVE HOT WATER TANK. O2 WATER HEATER AS SPECIFIED AND IN COMPLIANCE KITH APPUCABLE CODES AND ORDINANCES. CONTRACTOR TO ENSURE DIMENSIONS OF THE HEATER ALLOW INSTALLATION ABOVE THE MOP SINK. REFER TO WATER HEATER DETAIL EXTEND WATER HEATER THRU CEILING IF NEEDED. O 1/2" HW & CW TO FAUCET AT MOP SINK: PROVIDE APPROVED BACKFLOW PREVENTION DEVICE ON SERVICE FAUCET AS NEEDED. CAULK AND SEAL BACK OF SINK TO WALL 4O 3/4" CW TO WATER FILTER & 3/4" CWF FROM WATER FILTER. PLUMBING CONTRACTOR TO FOLLOW MMNFACTURER'S INSTALLATION INSTRUCTIONS AND ACTIVATION PROCEDURES FOR FILTERS. INSTALL ASSEMBLY ON WAIL. REFER TO WATER FILTER DETAL 5O 1/2" HW & CW TO FAUCET & SPRAY AT COMPARTMENT SINK AND AT WORK SINK. CAULK AND SEAL BACK OF SINK TO WALL . 6 3/4" HW TO SMNIIZER. INSTALL SHUT —OFF WIJH 3/4" MALE HOSE —END FITTING AT 18" A.F.F. AR F.F. UNDER COMPARTMENT SINK. SHUT OFF TO INCLUDE PRESSURE REDUCING VALVE, PRESSURE GAUGE (SET 0 20 PSG. +/— 5 PSIG . LINE STRAINER, AND SHOCK ARRESTOR IN WALL CONNECT WITIZ R TO HW SUPPLY WITH 72" LONG BRAIDED STAINLESS SEEEL HOSE. 0 0 0 1/2" CWF TO ICE MACHINE. REDUCE TO 3/8' AT MACHINE 1/2" TW & CW TO HANDSINK. 1/2" OF TO COFFEE BREWER. INSTALL SHUT —OFF IN CABINET 024' AFF REDUCE TO 3/8 ' AT UNIT. 1/2' CWF TO ESPRESSO MACHINE CONNECT 3/8" BRAIDED STAINLESS STEEL HOSE FROM SHUT —OFF TO ESPRESSO MACHINE WATER INLET. 1/2" CW TO DIPPERYEIL FAUCET. 3/8" CVIF TO HOT TAP. REDUCE TO 1/4 " AT UNIT. 3/8" CWF TO WATER TONER FAUCET LOCATED IN WATER STATION. 1/2' CW TO TOILET. NUR NOT USED. 3/4' CW STUB —UP THRU FLOOR W/BALL SHUT -OFF VALVE 3/4" CWF STUB —UP THRU FLOOR W/BALL SHUT —OFF VALVE WATER SUBMETER— CONFIRM REQUIREMENTS. VERIFY BACKFLOW PREVENTOR REQUIREMENTS OF EQUIPMENT & MAN WATER SERVICE TO STARBUCKS WITH INSPECTOR BEFORE BID. BACKFLOW PREVENTERS SHALL BE FURNISHED. INSTALLED. & INSPECTED PER CODE (NOT NECESSARILY SHOwN). O 1/2" CW TO PITT HER RINSER SINK FAUCET. MI BACKFLOW PREVE NTERS PER AHJ REQUIREMENTS & PER CODE O PRESSURE REGULATOR. E PEE EXCEEDS 65 PSI AT STARBUCKS SPACE. SEE SHEET P3.0 FOR TAG AND LOCATION. 3/4" CW TO FREEZE PROOF 1 BINS.. INSTALL IN ALTERNATE LOCATION IIfNEEDED DUE TO CONSTRUCTION. ROUTE PIPING ON WARM SIDE OF INSULABOIL 1" GAS TO ROOF TOP HVAC INN 111TH APPROVED SHUT —OFF VALUE: TIE INTO LANDLORD PROVIDED DOMESTIC WATER SERVICE VQRFY LOCATION PAD REQIOREf MENTS ON SE BEFORE BD. 3/4" GAS TO WATER HEATER UM APPROVED SHUT —OFF VALVE_ ROUTE PPES BELOW STAB. crTv. 416 21 n7 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE. WASHINGTON 98134 (206) 318 -1575 1TESE PINTS INTO SPECIFICARONS. AS 1REIL AS STxRR CT S' NNW AND LOCO. 1INLENATUiS MD OErCNS ARE THE OKUJSNE PROPERTY Of SW®UCKS CORPORATION. ANY REPRODUCTION. NOOFIC 1i0N, O6CWSUME AND/OR USE or nESE wows (pt PM PORIION OF 1) 1) IN TIM SWIBUCter PRIOR riTRTUEN 00/5D if 5 STRICTLY PROIIBOED. AER ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND. WA 98033 A co (425) 739-6051 (425) 739 -7362 AERI230AOLCOM REV DATE JC DESCRIPTION L W w s Q. L a0 o -- 00 0 c u) a) co oS U 0) U Q m `d"• C 0 C z <a) CO ca co _c •s 0 DIN z Ui O 0. STORE #: 14274 PROJECT #: 42071 -001 CONCEPT: ISSUE DATE CHECKED: DESIGNED: DRAWN: MSS 07/23107 JOHN BEEBE CHRIS RENSCH SHARON HARRIS SHEET TITLE PLUMBING SUPPLY PLAN 8 SCHEDULE SCALE: (DO NOT SCALE DRAWINGS) SHEET NUMBER P2.0 N01E: 1. SEE UNDERSLAB CONDUIT PLAN FOR ADDITIONAL UNDERSLAB ITEMS. 2. ALL INDIRECT DRAINS SHALL RUN SEPARATELY FROM FIXTURE TO INDIRECT DRAIN RECEPTOR AND SHALL TERMINATE W/ AN AIR GAP PER CODE UNLESS INDICATED OTHERWISE. LOCATE TO OF U.C.REFER I I i E 1 _L_ ,J t PLUMBING WASTE / VENT PLAN 0 1 2 3 4 8 12 r• tF ., WOMEN'S RESTROOM M EN'S RESTROOM PLUMBING GENERAL NOTES ® F&I A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. ® FOR FULL SCHEDULES AND COMPLETE USING SEE SCHEDULES. CONFIRM ALL QUANTITIES WITH PLAN. CI PLUMBING CONTRACTOR RESPONSIBLE FOR Slit INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. UD COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO AU. PLULi81NG EQUIPMENT. • DIMENSIONS ARE TO FACE UNLESS OTHERWISE NOTED. CI ALL INDIRECT DRAIN LINES SHALL BE ROUTED WITHOUT DIPS OR SAGS TO TERMINATE NTH AN AIR GAP INTO AN APPROVED INDIRECT WASTE RECEPTOR. CI REFER TO DETAILS FOR FURTHER REQUIREMENTS. DESIGN FOR SEWER AND GREASE WASTE UNES SHOWN IS BASED ON 1/8' PER FOOT SLOPE DUE TO EXISTING SHALLOW INVERT CONNECTIONS. CONTRACTOR SHALL CONFIRM WITH INSPECTOR & AUTHORITY HAVING JURISIICIINN IF 1 /8" PER FOOT SLOPE IS ACCEPTABLE PRIOR TO NSTALL CONTACT AIR ENGINEERS IF 1/8' PER FOOT SLOPE IS NOT ACCEPTABLE OR NOT OBTAINABLE. 0 3/4" PRESSURE RELIEF FROM WATER HEATER TO OP SINK. 0 1' INDIRECT DRAIN FROM WATER HEATER DRIP PAN TO MOP SINK. 3" WASTE /2'V FROM MOP SINK. 2' DIRECT NEEDED DRAIN FROM COMPARTMENT SINK. COORD. W/ AHJ PRIOR TO BID & FM INDIRECT IF . CI 1 -1/2' INDIRECT DRAIN FROM DISHWASHER TO FLOOR SINK. DISHWASHER IS NOT ALLOWED ON GREASE WASTE LINE. (SEE DETAIL). 0 (2) 3/4' INSULATED INDIRECT DRAINS FROM ICE MACHINE TO FLOOR SINK. DO NOT INTERCONNECT DRAINS. ® INSTALL FEMALE PIPE THREAD FROM ESPRESSO MACHINE DRAIN TRAY TO INDIRECT HUB DRAIN. 2" INDIRECT LINE FROM HUB DRAIN TO FLOOR SINK. 0 0 CD 0 0 0 m 0 PLUMBING KEY NOTES ® 1" INDIRECT DRAIN FROM DIPPER WELL TO FLOOR SINK. ® 1 -1/2' INDIRECT INSULATED DRAINUNE FROM ICE BIN DROP TO FLOOR SINK. 1O 1 -1/2' INDIRECT DRAIN FROM WATER STATION DRAIN BOARD TO FLOOR SINK. 3' WASTE /2 "V FROM FLOOR SINK. 2' WASTE /1 -1/2"V FROM SINK. 4' WASTE/2"V FROM TOILET. NUMBER NOT USED. WRAPPED CONDENSATE DRAIN FROM MR HANDLING UNIT TO FLOOR SINK OR MOP SINK. VERIFY SIZE & LOCATION OF DRAIN BASED UPON EQUIPMENT REQUIREMENTS AND PLACEMENT. FM CLEA NOUTS AS NEEDED. FLOOR CLEAN OUT, MATCH SIZE TO DRAIN LINE. NUMBER NOT USED. EXTEND TO BUILDING SANITARY WASTE. VERIFY LOCATION, INVERTS AND REQUIREMENTS ON SITE BEFORE BID_ 19 1" INDIRECT DRAIN FROM CBS DRAINBOARD TO HUB DRAIN. ® 2'W 1 -1/2 "V FROM PITCHER RINSER SINK. F NOT ALLOWED, PROVIDE 1-1/2" INDIRECT DRAIN. VERIFY WITH AHJ BEFORE. 21 F&I ANY NEEDED INDIRECT PIPING FROM BBA W DEVICES TO FLOOR SINKS (1YPXNOT ® FM ALL NEEDED INDIRECT PIPING (NOT NECESSARILY 23 EXTEND TO BUILDING GREASE WASTE VERIFY LOCATION, INVERTS AND REQUIREMENTS ON SITE BEFORE BID. 24 MAINTAIN 10' SEPARATION FROM HVAC UNITS. ADJUST LOCATION AS NEEDED. 25 3/4" INDIRECT DRAIN FROM WATER FILTER EQMPMENT TO MOP SINK OR FLOOR SINK. ® EVEN THOUGH INDIRECT PIPING IS SHOWN AT THIS LOCATION, IT IS NOT SHOWN ELSEWHERE. ( ALL P —TRAPS (WITH INTEGRAL UNION) & TAIL PIECE TO BE TYPE ABS UP TO AND INCLUDING THREADED COUPLING TO BASKET STRAINERS AT ALL SINKS. ® FM WALL CL.EANOUTS AT ALL SINKS AND AS NEED (NOT SHOWN— TYPICAL). =• - - - • ' ` . ) SEE SCOPE OF WORK ON SHEET P1.0 ., • • giof- 9,1c; AUG z ; p • I • .R ( r !i1! r ) � � O? B� c � V 0 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 nESE PLANS AID AS 10EOL AS ST/MUCKS' wWE NO TOM 1RADOORKS NO DE51GSG Aim THE DtCUISK PROPERTY Of SrARDUCKS CORPORATION. ANY REPRODUCTION. 1/001F1GnON, DISCLOSURE NO/OR USE of THESE wUERwS (OR N f PORTION Of n#AI) MOUT SMOCKS' PRIOR 1110T01 CORSENF 5 STRICTLY FROHeM AER ENGINEERS 11155 120TH AVE. N.E. (425) 7394051 SUITE 200 (425) 739 -7362 KIRKLAND. WA 98033 AEW23•AOl.00e REV DATE JC DESCRIPTION 0 WA 981 STORE #: 14274 PROJECT #: 42071 -001 CONCEPT: MSS ISSUE DATE 07/23107 CHECKED: JOHN BEEBE DESIGNED: CHRIS RENSCH DRAWN: DAN PURAVET SHEET TITLE PLUMBING WASTE I VENT PLAN SCALE: (DO NOT SCALE DRAWINGS) SHEET NUMBER P3.0 N01E: 1. SEE UNDERSLAB CONDUIT PLAN FOR ADDITIONAL UNDERSLAB ITEMS. 2. ALL INDIRECT DRAINS SHALL RUN SEPARATELY FROM FIXTURE TO INDIRECT DRAIN RECEPTOR AND SHALL TERMINATE W/ AN AIR GAP PER CODE UNLESS INDICATED OTHERWISE. LOCATE TO OF U.C.REFER I I i E 1 _L_ ,J t PLUMBING WASTE / VENT PLAN 0 1 2 3 4 8 12 r• tF ., WOMEN'S RESTROOM M EN'S RESTROOM PLUMBING GENERAL NOTES ® F&I A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. ® FOR FULL SCHEDULES AND COMPLETE USING SEE SCHEDULES. CONFIRM ALL QUANTITIES WITH PLAN. CI PLUMBING CONTRACTOR RESPONSIBLE FOR Slit INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. UD COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO AU. PLULi81NG EQUIPMENT. • DIMENSIONS ARE TO FACE UNLESS OTHERWISE NOTED. CI ALL INDIRECT DRAIN LINES SHALL BE ROUTED WITHOUT DIPS OR SAGS TO TERMINATE NTH AN AIR GAP INTO AN APPROVED INDIRECT WASTE RECEPTOR. CI REFER TO DETAILS FOR FURTHER REQUIREMENTS. DESIGN FOR SEWER AND GREASE WASTE UNES SHOWN IS BASED ON 1/8' PER FOOT SLOPE DUE TO EXISTING SHALLOW INVERT CONNECTIONS. CONTRACTOR SHALL CONFIRM WITH INSPECTOR & AUTHORITY HAVING JURISIICIINN IF 1 /8" PER FOOT SLOPE IS ACCEPTABLE PRIOR TO NSTALL CONTACT AIR ENGINEERS IF 1/8' PER FOOT SLOPE IS NOT ACCEPTABLE OR NOT OBTAINABLE. 0 3/4" PRESSURE RELIEF FROM WATER HEATER TO OP SINK. 0 1' INDIRECT DRAIN FROM WATER HEATER DRIP PAN TO MOP SINK. 3" WASTE /2'V FROM MOP SINK. 2' DIRECT NEEDED DRAIN FROM COMPARTMENT SINK. COORD. W/ AHJ PRIOR TO BID & FM INDIRECT IF . CI 1 -1/2' INDIRECT DRAIN FROM DISHWASHER TO FLOOR SINK. DISHWASHER IS NOT ALLOWED ON GREASE WASTE LINE. (SEE DETAIL). 0 (2) 3/4' INSULATED INDIRECT DRAINS FROM ICE MACHINE TO FLOOR SINK. DO NOT INTERCONNECT DRAINS. ® INSTALL FEMALE PIPE THREAD FROM ESPRESSO MACHINE DRAIN TRAY TO INDIRECT HUB DRAIN. 2" INDIRECT LINE FROM HUB DRAIN TO FLOOR SINK. 0 0 CD 0 0 0 m 0 PLUMBING KEY NOTES ® 1" INDIRECT DRAIN FROM DIPPER WELL TO FLOOR SINK. ® 1 -1/2' INDIRECT INSULATED DRAINUNE FROM ICE BIN DROP TO FLOOR SINK. 1O 1 -1/2' INDIRECT DRAIN FROM WATER STATION DRAIN BOARD TO FLOOR SINK. 3' WASTE /2 "V FROM FLOOR SINK. 2' WASTE /1 -1/2"V FROM SINK. 4' WASTE/2"V FROM TOILET. NUMBER NOT USED. WRAPPED CONDENSATE DRAIN FROM MR HANDLING UNIT TO FLOOR SINK OR MOP SINK. VERIFY SIZE & LOCATION OF DRAIN BASED UPON EQUIPMENT REQUIREMENTS AND PLACEMENT. FM CLEA NOUTS AS NEEDED. FLOOR CLEAN OUT, MATCH SIZE TO DRAIN LINE. NUMBER NOT USED. EXTEND TO BUILDING SANITARY WASTE. VERIFY LOCATION, INVERTS AND REQUIREMENTS ON SITE BEFORE BID_ 19 1" INDIRECT DRAIN FROM CBS DRAINBOARD TO HUB DRAIN. ® 2'W 1 -1/2 "V FROM PITCHER RINSER SINK. F NOT ALLOWED, PROVIDE 1-1/2" INDIRECT DRAIN. VERIFY WITH AHJ BEFORE. 21 F&I ANY NEEDED INDIRECT PIPING FROM BBA W DEVICES TO FLOOR SINKS (1YPXNOT ® FM ALL NEEDED INDIRECT PIPING (NOT NECESSARILY 23 EXTEND TO BUILDING GREASE WASTE VERIFY LOCATION, INVERTS AND REQUIREMENTS ON SITE BEFORE BID. 24 MAINTAIN 10' SEPARATION FROM HVAC UNITS. ADJUST LOCATION AS NEEDED. 25 3/4" INDIRECT DRAIN FROM WATER FILTER EQMPMENT TO MOP SINK OR FLOOR SINK. ® EVEN THOUGH INDIRECT PIPING IS SHOWN AT THIS LOCATION, IT IS NOT SHOWN ELSEWHERE. ( ALL P —TRAPS (WITH INTEGRAL UNION) & TAIL PIECE TO BE TYPE ABS UP TO AND INCLUDING THREADED COUPLING TO BASKET STRAINERS AT ALL SINKS. ® FM WALL CL.EANOUTS AT ALL SINKS AND AS NEED (NOT SHOWN— TYPICAL). =• - - - • ' ` . ) SEE SCOPE OF WORK ON SHEET P1.0 ., • • giof- 9,1c; AUG z ; p • I • • - .s • • • ▪ • e . • • • e • • .. : _ • • S .. CONFIRM REQUIREMENTS 1MTIH LANDLORD. . • 3" WASTE TO DRAIN FLOOR SINK DETAIL N.T.S. NTS II FLOOR SIE SET FLUSH W/TOP FiN. FLR. (CONTRACTOR TO CONFIRM WITH AHJ IF FLOOR SINK IS TO BE ELEVATED ABOVE SLAB) CAULK JOINT CONC. INFILL 0 TRENCH • : •�� FOR BELOW GRADE • • ° • • NUDES SEALANT DRAW BAND GRAVEL BAQ(FILL NO —HUB CONNECTION GAS PIPING. EXTEND ABOVE ROOF AS REQD. BY CODE. REFER TO PLANS FOR PIPE SIZES) & LOCAHON(S). PREFABRICATED COVER ROOFING PATCH LAP UP OVER PIPE SEAL LOGE OF COVER W/ LAP EDGE SEALANT SEE LANDLORD REQUIREMENTS & DRAB LANDLORD REQUIREMENTS GOVERN. THIN SET CERAMIC RE, 1W. COORDINATE WITH GENERAL ON TYPE OF FLOORING AND FLOOR SYSTEM, ETC. PROVIDE 12' MIN CLR BAN PIPE PENENTRAHON & OTHER PENE1 ATIONS, ORBS OR PIPE / ROOF PENETRATION 3/8' COPPER LINE 1/2' COPPER UNES 3/8' COPPER UNE MACHINE AMAIN BARISTA S 3/4' FILTERED SUPPLY 'FILTERED' = A— SYSTEM — GIVE REFER TO SUPPLY B— SYSTEM — Cm PIPING DIAGRAM C— SYSTEM — RO BARISTA FILTERED WATER MANIFOLD SCHEMATIC NTS GALVANIZED PIPE CLAMP DO NOT CLAMP TIGHT MACHINE 3//881 . MALE COMPRESSION 3/8' MALE COMPRESSION BALL VALVE A 1/2' COPPER ONES BALL VALVE 0 STUB UP S IF ONLY ONE ESPRESSO IS SHOWN IN PLAN VIEW AT THE FRONT UNE, F8c1 PIPE TO FUTURE LOCATION & BALL VALVE. 1/4 ' x 1 -1/2' GAL LAG BOLT EXISTING ROOFING OVER ROOF DECK 4x6 x 12' TREATED SUPPORT BLOC( W/ V —NOTCH ROOF WALK MAT BASE SHEET 18' x 18" x 1/2 ' THICK SUPPORT SPACING FOR PIPE SIZE 3/4 ' = 6', 1' = 7, 1 -1/4' = 8', 1- 1/2' =9' PLACE BASE SHEET OVER ROOFING GRAVEL OF ANY). SET BLOCKS FREE ON BASE SHTS. STACK BLOCKS & NAIL TOGETHER WHERE REQD. TO ELEVATE PIPING. INSTALL GAS PIPE TO ALLOW FOR EXPANSION & CONTRACTION. PRIMER AND PAINT DM PIPE LIGHT GREEN COLOR. PIPE SUPPORT NTS CHEMICAL CLEANER —MOUNT BRACKET ON CENTER W/ BOTTOM! OF CLEANER DISPENSER MOP SINK FAUCET (W/ ATMOSPHERIC BREAK) 'WASTING TEE' PROVIDED WITH CHEMICAL � W /QUQG S lJTTN3F SHALL NOT BE USED EVEN F SHOWN ON ARCH DETAILS) FRESH WATER HOSE W /QUQC DISC. FITTING MOP SINK BASIN NTS SEE LANDLORD REQUREMENIS & DRAWINGS. LANDLORD REQUIREMENTS GOVERN. ■ ■ ■ ■ I ■ I ■ I TOP VALVE. (TIP) /4" COPPER UNE 3/8' COPPER UNE WATER TOYER DISPENSER CLEANER —MOUNT TO BACK WALL OF MOP SINK SURROUND SEE ARCH DETAILS FOR I FURTHER INFORMATION CHEMICAL MIXER DETAIL 3/4' BY —PASS LINE , CHROME ESCUTCHEON TYP 3/4' COPPER DOMESTIC WATER IN. BALL SHUT —OFF — VALVE (REPLACE VALVES SUPPLED W/ FILTER W/ NEW BRASS ONES —TIP.) FLOOR DISHWASHER DRAIN DETAIL DISHWASHER NTS N.T.S. SINK/ICE BIN ABS THREADED COUPLNG TO BASKET STRAINER "A" FILTER SYSTEM N.T.S. CLEANOUTS AT ALL CHANGES- - ----a " IN BY I�CTION (OR AS ALLOWED ABS OW FITTINGS (TIP.) 21' FLOOR SINK 3/4 ' CWF OUT FLUSH VALVE — Fdd FLEXIBLE INDIRECT DRAIN ALL THE WAY TO RECEPTOR. N NEEDED. ABS INDIRECT DRAIN PIPE (SEE PLAN FOR SIZES &l ADDITIONAL OffWTS AS MAY BE NEEDED. PIPE Q.AMP SUPPORT AT (�OI TERMINATION —N SHO N) INTO OPEN AREA OF FLOOR SINK W/2' AIR GAP ��- FLOOR F — FLOOR SINK NOTES: 1. F&I ALL WORK PER CODE AND AHJ REQUIREMENTS EVEN F NOT SPECIFICALLY SHOWM. 2. ALL PIPES SHALL BE RIGIDLY SUPPORTED AND ALL SUPPORTS & PIPING SHALL BE MOUNTED OFF THE FLOOR FOR CLEANING PURPOSES. 3_ ALL INDIRECT DRAIN DISCHARGES SHALL OCCUR OVER CLEAR AREA Cr FLOOR SINK AND NOT OVER GRATE 4. / PIPES U PER ) F&I TRAPPED INDIRECT DRAIN AND VENT F REQUIRED BY CODE SINK INDIRECT DRAIN DETAIL +n� PIPE HANGER SUPPORT (OR PIPE CLANK SUPPORT AS VENT CAP ROOF —' DIELECTRIC UNION, TIP. APPROVED — GAS SHUT —OFF VALVE DOMESTIC GAS WATER HEATER DIRT LEG — MOP SINK FLOOR —\ NTS SLOPE PIPE PER 000E SEE PLANS) FOR SIZE. GALVANIZED MESH SCREENING GAS WATER HEATER ELEVADON NTS UNIS1RUT ANCHORED TO CURB. CLAMP REFRIGERANT LINES TO UANISTRUT. ROOF PENETRATION DETAIL N.T.S. NOTE THIS ROOFING PENETRATION DETAIL IS TO BE USED FOR REFRIGERANT LINES SERVING CONDENSER AND /OR HEAT PUMPS. VENT IF REQUIRED BY CODE AHJ TO UTSIOENOT CONNECT TO ANY SEWER VENT) TURNS S P 7 W/2 AIR INTO OPEN AREA (OR AS ALLOWED BY CODE) NOTES 1. Fdd ALL WORK PER CODE AND MU REQUIREMENTS �� FLOOR SNNK(OR FUNNEL EVEN IF NOT SPECIRCALLY SHOWN. DRAIN) 2. ALL PIPES SHALL BE RIGIDLY SUPPORTED AND ALL SUPPORTS & PIPES SHALL BE MOUNTED OFF THE FLOOR FOR CLEANING PURPOSES. 3: ALL FLOOSIE INDIRECT DRAIN LINES FOR APPUANCES SHALL BE INSTALLED PER CODE /MU AND MMIUF. REQUIREMENTS. SUPPORT LINES SO THERE ARE NO SAGS OR DIPS IN LINE: SEE SCOPE OF WOW ON SHEET PLO HT. AND LOCATION PER CODE TYPE 8 VENT THROUGH ROOF WATERPROOF PENETRATION EXPANSION TANK MODEL AMTROL ST -5 —C \ (OR AS REQUIRED BY LOCAL CODE) COMBINATION P & 1 RELIEF VALVE 3/4 ' RELEF DRAIN TO MOP SINK STRAP TO WALL STRUCTURE W/ 2 RIDE 16 GA STEEL BAND DRAIN VALVE DRIP PAN WITH INDIRECT DRAIN TO MOP SINK BELOW SUPPORT PLATFORM BY OTHERS (SEE DETAIL) 3/4 ' INDIRECT DRAIN TO MOP SINK 20 GA. GALVANIZED SHEET METAL HOOD FILL OPENING %MTH FOAM INSULATION AIR TIGHT AFTER LINES ARE INSTALLED. ROOF CURB REFRIGERANT LINES (INSTALL PER CODE) FLASHING, ROOFING, AND CONTRACTORS REQUIREMENTS. TOP OF ROOF DEC( CONNECT TO EQUIPMENT INDIRECT DRAINS —TRAP IF REQUIRED PER CODE OR MU CONDENSATE DRAINS —TRAP REQUIRED INSTALL PER MANUF. /000E REQUIREMEN MATERIAL SHALL BE PER THESE PLANS AND/OR PER CODE. USE DWV RTIRIOS IF REQUIRED BY CODE /NUJ: CONDENSATE /EQUIPMENT INDIRECT DRAIN DETAIL zic L.6?I a , STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 MESE PUNS MD SPECIMUIONS. AS MIL S ME AND WOO, MMUS MO OMENS ARE TIE OcaU51VE FROPERIY Of SDROIJOM II. MY REPRODUCTION. �1ESE� ss ( POORUON or MO WHOM =MOW PRIOR WW1 OONSO1f IS SICILY PROD AER ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 REV DATE JC DESCRIPTION w as L W w a. u : L Co o CD CO U 2 c u) 4) co : oS o o UL Q 1 m • c oo z < W (/) r" �- 0 _ O O u) }, o o v .�C 0 O I L :z (l) Cl)1 - STORE #: 14274 PROJECT #: 42071-001 CONCEPT: ISSUE DATE: CHECKED: DESIGNED: DRAWN: (625) 739 -6051 (425) 739 -7362 AERI230A01...c H - 0 a MSS 07/23/07 JOHN BEEBE CHRIS REEISCH SHARON HARRIS sxEEr TITLE PLUMBING DETAILS SCALE_ (D0 NOT SCALE DRAWINGS) 9fE4 P4.0 •